HomeMy WebLinkAbout2723 OCEAN ST; ; 85-487; Permit0 I hereby affirm that I am licensed under
- provisions of Chapter. 9 (commencing with I - Section 7) of Division 3 of the Business
and Professions Code, and my license is in
I full force and effect.
[,,, i,c. No ________________ Class
0 UI— - I hereby-affirm that I am exempt from the Contrac-
tors License Law for the following reason (Sec. 7031.5 Oucinoss and Prof erwivns Code; Any city or county which ro quires a permit in construct . alter, improve, demolish, or repair any structure. prior to its issuance also requires the ap-
plicant for such permit to file a signed statement that he is Iitenovil pnrvllOut In the prnvisienr of the r.'nntrrIe"
License Law (Chapter 9 commencing with Section 7005 CI Division 3 of the Businonc and Prolensions Coda) or 11131 inns
cmpl therefrom and the basis for the alleged exemption. Any
violation of Suction 7031.5 by an applicant [or a permit sub' j0cic the applicant to a civil penalty 01 not more than live hun
dred dollars ($500).
O I, as owner 01 the properly, or my employees with wagon
an their solo compensation, will do the work, and the struc-ture is not intended or offered for 5310 (Soc. 7044, 8usinss
and Professions Cede: The Contractor's License Law does
001 apply to an owner 01 property who builds or improves thereon and who does such work himself or through his own
employees, provided that such improvements are not blend-ed or oltered for sale. It, however, the building or improve-
ment is sold within one year 01 completion, the owner-builder
Will have the burden of proving that he did not build or im-
prove for the purpose of sale).
I. as owner 01 the preperty, am exclusively contracting
with licensed contractors In construct the project (Sec. 7044. Business and Professions Cede: The Contractor's License
Law does 001 apply loan owner 01 properly who builds or im-proves Ihereon, and who contracts ter each projects with a
contractor(s) license pursuant to the Contractor's License Law).
An a homeowner lam improving my home, and the follow-ing conditions exist:
The work is being performed prier to sale. - I . have lined in my home for twelve months
prior to completion 01 this work.
I have not claimed this exemption durieg the last three years.
lam exempt under Sec. _________________ , B& P.C.
for this reason
UI 0 -I
m
UI Z
0
I hereby affirm that I have a certificate 01 consent Is
sell-insure, or a certificate 01 Workers' Compensation In
surance. or a certified copy thereat (Sec 3800. Labor Code
POLICY NO.
COMPANY
Copy is filed with the city
0 Certified copy is hereby furnished
CERTIFICATE OF EXEMPTION FROM
WORKERS' COMPENSATION INSURANCE - (This section need not be completed it the permit
is for one hundred dollars (5100) or less)
O 1 certify that In the performance at the work for whici
this permit is issued. I shall not employ any person in ant
manner so as to become subject to the Workers' Compen
salion Laws of California.
NOTICE TO APPLICANT: It. alter making this Cerliticall
01 ExemptiOn, you should become subject laths Workers
Compensation provisions 01 the Labor Code, you musi
forthwith comply with such provisions or this permit ahal
be deemed revoked.
[" 0 I hereby affirm that there Is a construction lendis)
far agency for the performance of the work for which this per
01 mit is issued (Sec. 3097. Civil Code) zi - - UI Lender's Name -
L Lender's Address -
USE BALL POINT PEN ONLY & PRESS HARD APPLICANT TO FILL IN INFORMATION WITHIN SHADED AREA AND DECLARATIONS.
CARLSBAD BUILDING DEPARTMENT -
. APPLICATION & PERMIf Carlsbad, California 92008-1989 (619) 438-5525
VALUATION PERMIT NUMBER JOB ADDRESS I AV, ST. RD. NEAREST CROSS ST. DATE F APPLICNN BUSIN4nNSE
ID o, o -o 0 A
LOT I8LO I5U80IVI5I N A SESSOR PAR NO ONTRACTOR CONTRACTORS PHONE 4 - _ d14 g
'• ZONE
(3 WNF A'S NAMF tZ
H-' ScwJ
OWNBRI Pb-lONE
[CfONTRACTOR'S ADDRESS .J
________________________________
LICENSE NO. PLAN I.D. # BUILDING SQ. FOOTAGE
C5 c_0 0 C/I ?.2C3
''oC, V?.LX 1-JCLLc
OESICNCn rri-fqj.. DESIGNER'S PHONE
i4i4 A- MbJ1 '1; 7V -a DESCRIPTION OF WORK 2. t DESIGNER'S ADDRESS LICENSE NO.
LLL-'3 Tfl?EB'19 _i,i9
F/P FLRELEV.I ' I NO '
I STORIES OCCGP EDU _T90 10213Y
YD NO
CENSUS TRACT GP LAND USE PARKING SPACE RES UNITS GRADING PERMIT ISSUED I REDEVELOPMENT I I TYPE 0CC LOAD FIRE SPA IAREA I IC0N5T
Y O N 0 I vO NO I YO NO Not Valid Unless Machine Certified
OTY. PLUMBING PERMIT - ISSUE '7 5-10 QTY. MECHANICAL PERMIT- ISSUE SUMMARY/ACCOUNT NUMBER
33 EACH FIXTURE TRAP .? INSTALL FURN. DUCTS UP TO 100,000 BTU BUILDING PERMIT 001-810-00-00-8220
EACH BUILDING SEWER . OVER 100,000 BTU . SIGN PERMIT 001-810-00-00-8221
- EACH WATER HEATER ANDiOR VENT , - BOILER/COMPRESSOR UP TO 3 HP , PLAN CHECK 001-810-00-00-8806
- EACH GAS SYSTEM I 104 OUTLETS ,
-
BOILER/COMPRESSOR 3.15 HP . TOTAL PLUMBING 001-810-00-00-8222
EACH GAS SYSTEM S OR MORE , METAL FIREPLACE ELECTRICAL 001-810-00-00-8223 1
EACH INSTAL., ALTER, REPAIR WATER PIPE
-
. , VENT FAN SINGLE_OUC1 -. 30— MECHANICAL 001-810-00-00-8224 —
EACH VACUUM BREAKER . MECH EXHAUST - HOOD/DUCTS , MOBILEHOME 001-810-00-00-8225
WATER SOFTNER . A CATION OF EA FURNACEIHEATER MOBILEHOME PARK INSP
EACH ROOF DRAIN (INSIDE) - : — .AR 001-810-00-00-8226
HANICAL
= .
I,
c:7-
STRONG MOTION - 880-519-92-33 -
TO JAL PLUMBING g — FIRE SPRINKLERS 001-810-00-00-8227
QTY. ELECTRICAL PERMIT- ISSUE
-
QTY. SOLAR-ISSUE PUBLIC FACILITIES FEE 332-810-00-00-8930
NEW CONST EA AMPiSWTlBKR.,O % 5 -
COLLECTORS - - SCHOOL FEE - DISTRICT -.
I PH 3 PH ' STORAGE TANKS - Carlsbad
EXIST BLDG EA AMPISWT/BKR - ROCK STORAGE - Encinitas
I PH - ' 3 PH - PUMP - San Oieguiio
REMOOEL:ALTER PER CIRCUIT . PLAN CHECK FEE - San Marcos
TEMP POLE 200 AMPS
OVER 200 AMPS ' LICENSE TAX 001-810-00-00-8162 -
TEMP OCCUPANCY (30 DAYS)
-
' -
-
,
I
MFF 880-519-92-57
' - CREDIT DEPOSIT
TOTAL ELECTRICAL
- i . —
TOTAL SOLAR - - - TOTAL FEES PAYABLE (t..,g3.3o —
I HAVE CAREFULLY EXAMINED THE COMPLETED "APPLICATION AND PERMIT" AND DO HEREBY I Expiration. Every permit issued by the Building Official under the provisions of this * AN OSHA PEiAtT IS REQUIRED FOR EXCAVATIONS OVER I Code shall expire by limitation and become null and void. If the building or work 50" DEEP AND DEMOLITION OR CONSTRUCTION OF CERTIFY UNDER PENALTY OF PERJURY THAT ALL INFORMATION HEREON INCLUDING THE authorized by such permit is not commenced within 180 days from the dale of such STRUCTURES OVER 3 STORIES IN HEIGHT DECLARATIONS ARE TRUE AND CORRECT AND I FURTHER CERTIFY AND AGREE IF A PERMIT IS I permib, or if the building or work authorized by such permit is suspended or ISSUED: TO COMPLY WITH ALL CITY. COUNTY AND STATE LAWS GOVERNING BUILDING CON- abandoned a( any time after the work is commenced for a period 01180 days STRUCTION. WHETHER SPECIFIED HEREIN OR NOT, I ALSO AGREE TO SAVE INDEMNIFY AND APPLICA RE . OWNER 0 BY DATE KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES. JUDGMENTS. COSTS AND
WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEOUENCE OF THE (j717 cL"z,..,
CONTRACTcE
,
yGNAT
GRANTING OF THIS PERMIT. IEXPENSES
[A.PPROVED
BY PHONE
110
1._. ...... ;.:'
kq V-7
FIELD INSPECTION RECORD
REQUIRED SPECIAL INSPECTIONS . INSPECTOR'S NOTES
CT • REQ. IF INSPECTOR'S :.
INSPECTI ON o CHECKED APPROVAL ATE
SOILS COMPLIANCE (
PRIOR TO I
FOUNDATION INSP
STRUCTURAL CONCRETE
OVER 2000 PSI
PRESTRESSED
CONCRETE .
POST TENSIONED
CONCRETE
'!FIELDWLDNG .-.
HIGH STRET-
BOLTS
-
"-S
SPECIAL MASONRY . .. -.
.
/........-S. -'
PILES CAISSONS
• . ,. ,... '
r '- •
77
TYPE DATE INSPECTOR
BUILDING
FOUNDATION
REINFORCED STEEL
MASONRY
GUNITE OR GROUT I
SUB FRAME 0 FLOOR 0 CEILING
SHEATHING 0 ROOF 0 SHEAR
FRAME
EXTERIOR LATH
INSULATION
INTERIOR LATH & DRYWALL
PLUMBING
O SEWER AND BL/CO 0 PL/CO
UNDERGROUND DWASTE DWATER
TOP OUT 0 WASTE 0 WATER
TUB AND SHOWER PAN
GAS TEST
O WATER HEATER 0 SOLAR WATER
ELECTRICAL
O ELECTRIC UNDERGROUND D'UFFER
ROUGH ELECTRIC
O ELECTRIC SERVICE 0 TEMPORARY
O BONDING 0 POOL
MECHANICAL
O DUCT & PLEM., 0 REF. PIPING
HEAT — AIR COND. SYSTEMS
VENTILATING SYSTEMS
CALL FOR FINAL INSPECTION WHEN ALL APPROPRIATE ITEMS ABOVE HA WE BEEN APPROVED
FINAL
PLUMBING . .
ELECTRICAL
MECHANICAL
GAS
BUILDING
SPECIAL CONDITIONS
City of Carlsbad MISCELLANEOUS
1200 ELM, CARLSBAD, A 920@8 • TEL.(619)438-5525 RECEIPT •
Address 72 ~&A
MISCELLANEOUS FEE RECEIPT,uJ 261'09'i
0 PLANCHECK FEE_ 0130008806
0 VALUATION ./I) - 1200
I 0 DEMOLITION_______________________
0 HOUSE MOVING
0 PARKS AND RECREATION FEE______________
0 PUBLIC FACILITIES FEE_________________
0 SCHOOL FEE - DISTRICT______________________
0 Carlsbad
Owner lO51 3O41V Sot'! -
Mailing Q Address 0O F&rrHlLt 1 P.
CilViX H4tc -
j7-/0c7
Contractor
65q K
Address 5. (TM A.IZ_.
City £24A/St IzP
Stale Lic. p,
IS.
mm.i
Classif. I //?,?. t,5 City
Lic. NO. 73
COMPLETE FOR PLAN CHECK ONLY
LEGAL DESCRIPTION R-3 L.. A I%IA P 122
0 . Encinitas______________________
0 San Diego
0 San Marcos
0 CERTIFICATE OF OCCUPANCY_____________
- -
ASSESSORS. PARCEL NO 03 1 41 0 Z o
DESCRIPTION OF WORK r—Cl
rç..1)1LO—Ern'1c p4-f-::
0 /
. -
PLAN IDNO.
DESIGNER ADDRESS _____-OtT__IR.
0ftJ5;DEL
PHONE L/'2,(/j
TOTAL FEE -
CONTACT PERSON 1PC OL 15 SQ\i . -. WARNING: PLAN CHECK FEES. WHERE NO ACTION IS TAKEN BY THE
APPLICANT IN 180 DAYS AND NO BUILDING PERMIT IS ISSUED. ARE
FORFEITED TO THE CITY.
COMMENTS: -
Signature of Applicant _ __________________ Date
White - Applicant Yellow - File ,,Pink (1) Finance (2) Data Process Gold - Assessor
[A Th
ESGIL CORPORATION
9320 CHESAPEAKE DR.. SUITE 208 C :olil bs.
SAN DIEGO, CA 92123
(619) 560-1468
ICAMT DATE: flAPPL
/ 0 JURISDICTION
JURISDICTION: 0 PLAN CHECKER
FILE COPY
PLAN CHECK NO:
U DESIGNER
PROJECT ADDRESS: 27' - 5 7 2--&79A/
PROJECT NAME:
D The plans transmitted herewith have been corrected where
necessary and substantially comply with the jurisdiction's
building codes.
The plans transmitted herewith will substantially comply
with the jurisdiction's building codes when minor deficien-
cies identified 01V 74- are resolved and
checked by building department staff.
The plans transmitted herewith have significant deficiencies
identified on the enclosed check list and should be corrected
and resubmitted for a complete recheck.
The check list transmitted herewith is the jurisdiction's
0 copy for your information. The plans are being held at
Esgil Corp. until corrected plans are submitted for recheck.
O The applicant's copy of the check list is enclosed for the
jurisdiction to return to the applicant contact person.
The applicant's copy of the check list has been sent to:
Esgil staff did not advise the applicant contact person that
plan check has been completed.
Esgil staff did advise applicant that the plan check has 0 been completed. Person contacted:
Date contacted: Telephone #__________________
REMARKS:
BY: 'rf ENCL:
ESG] CORPORATION
(c3(J -
51GS
TL .LQ J&\avjF t1) '9
k1 L V77If • cç C' 0L rF5 Lktk i OS
3 L4 J4A ( '.' 3- 0 Xi' -
) 0 i)
t
& . (U O Z)t
---rnQh
6170-1 rn -,
1
ESG.IL CORPORATION
9320 CHESAPEAKE DR., SUITE 208
SAN DIEGO, CA 92123
(619)560-1468
DATE:
JURISDICTION:
PLAN CHECK NO: d6 6497
PROJECT ADDRESS:"
PROJECT NAME:
PLAN CHECKER
FILE COPY
UPS
DESIGNER
D The plans transmitted herewith have been corrected where
necessary and substantially comply with the jurisdiction's
building codes. -
The plans transmitted herewith will substantially comply
with the jurisdiction's building codes when minor deficien-
cies identified are resolved and
checked by building department staff.
The plans transmitted herewith have significant deficiencies
identified on the enclosed check list and should be corrected
and resubmitted for a cbmplete recheck.
The check-list transmitted herewith is the jurisdiction's
El copy for your information. The plans are being held at
Esgil Corp. until corrected plans are submitted for recheck.
The applicant's copy of the check list is enclosed for the
jurisdiction to return to the applicant contact person.
The applicant's copy of the check list has been sent to:
Esgil staff did not advise the applicant contact person that
plan check has been completed.
Esgil staff did advise applicant that the plan check has 0, been completed. Person contacted:
\ Date contacted: Telephone #________________
REMARKS:
/ I
/ BY: ENCL:
IL CORPORATION
- .- - --- -
;. •%.
.'
0 APPLICANT COPY
CITY COPY
o PLAN CHECKER COPY
Citp of Cartbab / Submit fully dimensioned plot plan drawn
to scale showing Location size, and use
of all existing and proposed structures
on the lot. Identify property Un.. and 'fll'2-5 show lot dimensions and all easements. Show location of all cut or fill slopes ( Y\ ZcrC. C? OL+1 Of1S) and approximate finish floor elevations for all structures and show elevations at all corners. Sec. 302(b)?.
JUR:soxcT:ON: OAT!___________
PROJECT ADDRESS a _''B d7 Oc
TO,
/ indicate distance from center-tine of street / or alley to property Line and distance from I curb to property line. Sec. 302(b)7
6/ Plans, specifications and calculations shall / be signed by a California State licensed " engineer or architect. (California
Business and Professions Code)
3. FIRR PROTECTION
if. Waits closer than 3 feet to property lines / shall be one-hour fire-rated construction,
have no openings, and shall have 30 inch parapets when the building floor area exceeds 1.000 square feet on any floor. (Table 5-A
,Sec. 1709(a)
Projections. including eaves, may not extend / more than 12 inches into the 3 foot setback
from the property line. Sec. 1710 and
See. 504(b)
X
Projections. including eaves,shall be one- hour fire-resistive construction, heavy
PLAN CORRECTION SRFZ?
SINCI.! FAMILY AND DUPLEX OWEtLINGS
Plan Check No.
Date plans received by jurisd1ction 754_' 8/i3/1?r
Date plans received by plan ch.ck.r*.A7 /iiJç
Date initial plan check completed. // DY...221
FOREWORD: PLEASE READ TeL (619) 604461) 9/ftS 4 Plan check is limited to technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, Nation.
rg))
Electrical Code and state laws regulating en.
conservation, noise attenuation and access for
tz.no.r or or non-colaDu3t1o. material .r they project into the 3' setback area from the property line. Sec. 1710
Show location of permanently wired smoke
detector. Sec. 1210
the handicapped. The plan check is based on ' 4 \ C. ROOM SIZES, LICWI', VENTILATIONS AND CT.AZINC regulations enforced by the Building Inspection 4.* Department. You may have other corrections I K' I '. One room must contain a minimum of 150 square based on laws and ordinances enforced by the \ ' J Y. feat of superficial floor area. Sec. 1207(b) Planning Department, Engineering Department
or other departments. .5.
The items circled below need clarification,
modification or change. All circled items have to be satisfied before the plans will be in
conformance with the cited codes and regulations. Per Sec. 303 (c), 1979 Uniform Building Code. the approval of the plans does not permit the violation of any state, county or city law.
2/ Habitable rooms, other than kitchens, shall
I contain at least 70 square feet of floor
area. Sec. 1207(b)
Window area must be at least 1/10 of the floor area and a minimum of 10 square feet per See. 1207(a). Appears to be deficient
in
26 Openable window area must be 1/20 of the floor area and a minimum of 5 square feet. In bathrooms, laundry rooms and similar rooms. Minimum is 1.3 sq.ft. (Sec.1205(4)
2 • One-half of all required window ares must be openable in ii'citY.
}I. Provide mechanical ventilation capable of / providing five air changes per hour in bathrooms, water closet compartment., laundry rooms and similar rooms if required windows
are not provided. Sec. 12031a)
31. No habitable room, other than a kitchen. / shall be less than 70 in any dimension. Sec. 1207(c)
4'. Show that ceiling height for habitable
/ rooms is a minimum of 7161. Sec. l77(aP
. PUNS
I. Please make all corrections on the original tracings and submit two new sets of prints.
and any original plan sets that may have been returned to you by the jurisdiction.
to:
2. To facilitate rechecking, please identify. next to each circled it.., the sheet of the plans upon which each correction on this sheet has been made and return this check sheet with the revised plans.
Indicate on plans the name of the legal owner and name of person responsible for the preparation jf the plans. Sec. 302(b)
)/ Show ceiling height for laundry rooms,
hallways. corridors, and bathrooms is a
minimum of 70". Sec. 1207(a)
34 Provide 30" cLear, width for water closet
compartments and 24" clearance in front
of water closet. Sec. 1711(b)
3/. No cooking room shall be used for sleeping - / purposes, unless complying as an efficiency
living unit. Sec. 1208
03- Specify safety glazing for glazing in hazardous
Locations such as glass doors, glazing
adjacent to such doors and glazing adjacent
to walking surfaces. Sec. 5406
37 Glazing in shower and tub enclosures
(including windows) shall be tempered,
laminated or approved plastic.
Sec. 1711 (f)(g)
3 Sleeping rooms shall have a window or / exterior door for emergency exit. Sill
height shall net exceed 44" above the floor.
The window must have an openable area of
at least 5.7 square feet with the minimum
openable width 20" and the minimum openable
/ height 24". Sec. 1204
Eaves and cornices may not project into
a required yard more than 2 inches for each
50 Handrails shall satisfy the following:
a. Provide handrail for stairways over 30"
high when serving a single dwelling.
Title 24, Sec. T25-22(b)
b Handrail shall be 30" to 34" above the
nosing of treads. Sec. 3305(j)
c. Handrail projecting from a wall shall
have a space not less than 1 1/2" between
the wall and the handrail. The hand grip portion of handrail shall
be not less than 1 1/4" nor more than
2" in cross-sectional dimension.
Sec. 3305(j) (see attached)
I 4'. Every stairway landing shall have a dimension,
measured in the direction of travel, at
least equal to the stairway width.
Sec. 3305(g)
A door may open over a stairway landing / provided the door, in any position, does
not reduce the clear area of the landing.
in the direction of stairway travel, to
Less than one-half the required width of
the stairway. Sec. 3305(g)
A door may open inward at the top step of / a stairway provided the top step is not
more than 7 1/2" Lower than the floor level.
Sec. 3303(i)2
foot of yard width if required windows
open into the yard. Sec. 1206(d) 54 Provide details of winding stairway.
Minimum tread is 6 inches at any point
•
A mezzanine is an intermediate floor and and minimum 9 inches at a point 12 inches i /may not have a floor area exceeding 33 1/3 rfrom the side of the percent of the total floor area in the room
below, and the mezzanine floor must have b. Maximum rise is 9 inches.
a clear height of 7 feet, above and below,and c. Minimum width is 30 inches. Sec. 3305(d) must have 65% of the long side open to the (see attached) room below.
4J The loft you show does not comply as a /. mezzanine floor and is. by Building Code
/ definition, a story______________________
D. EXITS, STAIRWAYS, AND RAILINGS
41 floors above the second story shall have / not less than 2 exits. Sec. 3302(a)
4/. Required exit doorways shall be not less / than 36" in width and not less than 6'-B"
in height, and shall be capable of opening
at least 90 degrees. Sec. 3303(e)
Provide 36" high protective railing for / porches, balconies, and open sides of landings.
Maximum opening between railings shall be
less than 9". Sec. 1716
Show how guardrail connection details are / adequate to support 20 pounds per lineal
( foot at a right angle to the top rail.
Table 23-3
Provide stairway and landing details.
I Sec. 3305(b) 5 (c)
Maximum rise 8" and minimum run is 9".
Minimum head room is 6-6".
Minimum width is 30".
Provide spiral stairway details:
I a. Minimum run is 7 1/2 inches at a point
fromwhere the tread is the narrowest.
Maximum rise is 9 1/2 inches.
Minimum headroom is 6 feet 6 inches.
Sec. 3305(f)
(see attached)
4. Sprial stairways may not be used for required
exits when the area served is greater than
400 sq. ft. Sec. 3305(f)
5/. Spiral stairways must have a clear walking / space of 26 inches between the column and
handrail. Sec. 3305(f)
5/. Provide t.C.8.0. Reasearch Report and Number
I for metal stairway, or submit plans and
calculations and approved fabricator
registered with the Building Department
or note that the stairway fabrication shall
be done under special inspection per the
approved fabrication plans. Sec. 306(a)48
and Sec. 306(f)
19. In buildings over 2 stories in height. provide
I 3/4 hour fire-rated assemblies for all
openings in the exterior wall below or within
10 feet horizontally of an exterior stair-
way. An exit balcony with 2 separated
stairways is ex.mpt. Sec. 3305
64. Exterior stairways shall not project into / the 3 foot setback from the property lines.
Sec. 3305(n)
a
(c;
M
fr?. The walls and soffits of the enclosed iseable / space under interior stairs shall be protected
on the enclosed side as required
for one- fire-resistive construction ce 3301
,. Minimum construction
i. be made a part of the approved p1
) (See attached) fo it
B. ROOFING
7
Specify roof pitch.
Roof pitch is not adequate for r f type / specified. Specify minimum pitch
-702 Specify roof material and
7.3.
applicati
'h- Specify I.C.3.O. approval number for roo
/ materials not covered in USC.
yf. Specify roof slope for drainage or design
to support accumulated water. Sec. 3207(a)
Show roof drains and overflows. Sec. 3207(a)
6. Provide skylight details.to show compliance
with Sections 3401 and 5207 or provide ICBO
approval number.
Provide plastic roof panel details to show ' compliance with Section 5206 or provide
/ IC8O number.
4'. Show attic ventilation. Minimum vent area / is 1/150 of attic area or 1/300 of attice
area if at least 50% of the required vent
is at least 3 feet above ceiling joists.
Sec. 3205(c)
d'Sh'. w 1 3/8" solid core self-closing door
for openings between garage and dwelling.
Sec. 503(d)
10 . Garages are not permitted to open into
a room used for sleeping purposes. Sec. 1104
V41 Openings between carport and residence
require seLf-closing doors and stationary
j windows. Sec. 1214
Show garage framing section, size of header
.l \ over garage opening, lateral cross bracing
' at plate line and method of bracing garage / front. Chapter 23
NOTE; Minimum plywood diaphragm ratio is
3 1/2 to 1 or VB". Table 24-I
Doors between dwellings and attached garages
may swing in either direction provided
the difference in floor elevation between
the dwelling and garage does not exceed
7 1/2 inches and provided the door is not
used as the primary means of egress from
the building.
If the difference in floor elevation exceeds
7 1/2 inches, or if the door is used as
the primary means of egress from the building,
additional steps or landing must be provided
in accordance with stairway requirements,
and the door must not swing over the depressed
level. (see 3303(i)2 and 3305 (g).
Provide 18" raised platforms for any FALJ,
water heater, or any other device which
may generate a flame or spark.
174. Note that continuous fire wall protection
shall be installed behind raised platform(s)
prior to framing platform.
B. MASONRY H. , FOUNDATION REQUIREMENTS
ProvideS fireplace construction details or )4. Note on plans thatA soils engineer shall
note construction to be per attached fireplace evaluate any unanticipated uncornpacted fill
standard drawing. Sec. 3707 or expansive soil or other soil problems
disclosed during construction". Sec.306(a)12.
with Sec. 3002, 4.5,6, and Sec. 2516(a) by a licensed engineer or architect .based
Show veneer support and connections complyC5~ Submit soils classification determination
regarding ties and 89 wire in horizontal,on observation, tests, borings, or excavations, joints or note construction to be perattach and containing comments on the degree of sheets 30-I or 30-2. expansiveness, compressibility and bearing compressibility
31 Show height and construction details of f / all masonry walls. Chapter 24
34. Note that cleanout openings shall b&provided / at the bottom of all cells to be grout filled
over 41 in a single pour. Cleanout shall
be sealed before grouting, after inspection.
/ Sec. 2415 7t. Show floor and roof connections to masonry
/ walls. Connection shall resist 200 pounds
per lineal foot or the actual design load,
whichever is greater. Sec. 2310
Provide material specifications for mortar. / grout, masonry and reinforcing steel.
Sec. 2403
9/. Show how masonry house walls retaining earth / are to be waterproofed. Provide detail.
9f. Note that special inspection of the masonry / will be required for__________________________
10 .Garage requires one-hour fire protection
on the garage side of walls and ceilings
common to the dwelling. Table 5-8 Sec.503(b)
l,p{.All elements supporting floor above garage / to have one-hour fire-resistive protection
on the garage side. Sec. 503. Beams and
posts, not within the wall or ceiling con-
struction, must comply with USC. Table 43-A,
or be minimum 6" dimension beam and minim
" 8" by B" post. __
.c. Ow tL
IL
Mbc :s6 CLo ev Ole,
/ value. Sec. 2905 -
Note on the plan the soils classification,
/ whether or not the soil is expansive, and
/ note the allowable bearing value. Sec. 2905
l~. The foundation plan does not comply with / the soil report recommendation for this I project_____________________________________
l. Provide notes on the foundation plan listing / the soils report recommendations for foundations.
slab and building pad preparation.
1/4. Note on the foundation plan that "Prior / to the Contractor requesting a Building
Department foundation inspection, the
soils engineer shall advise the Building
Official in writing that:
I. the building pad was prepared in accor-
dance with the soils report;
the utility trenches have been properly
backfilled and compacted, and:
the foundation excavations, forming
and reinforcement comply with the soils
report and approved plan."
L. Provide spread footings for concentrated / loads designed for 1,000 PSF soil bearing
or per bearing value as determined by
an engineer or architect. Chapter 29
CftL=14.
1L.. tE7j. S'co?t.,o
0l
W iZoS1oM
Show height of all foundation walls. Chapter 2,3 llote cross bridging or blocking. Floor
Show height of retained earth on all foundation joists and rafters more than 12" in depth
and spanning more than 8 feet shall be
/I
walls. Chapter 23
Show distance of foundation to edge of
supported laterally by bridging at intervals
exceeding 8 feet. Sec. 2506(g)
cut or fill slopes and show steepnass and
/not
Show blocking at ends and at supports heights of cuts and fills. Chapter 29 of floor joists, and for rafters at exterior
Note on plans that wood shall be 6" above
finish grade. Sec. 2417(c) 7.
walls. Sec. 2506(g)
Show solid blocking at ridge line and p130 Note on plans that surface water will drain
away from building and show drainage pattern
at exterior walls on trussed roofs.
Sec. 2506(g)
and key elevations. Sec. 2905(f) Show double joists. Floor joists shall
Dimension foundation per Table 29A. be doubled under bearing partitions running
parallel with the joists. Sec. 2518(d) 5
TABLE NO. 29.A—FOUNDATIONS FOR STUD BEARING p Show rafter ties. Rafter ties shall be
spaced than 4 feet not more on center WALLS—MINIMUM REQUIREMENTS where rafters and ceiling joists are not
naraLlel Sec 2SIR(h)
/
. Show rafter purlin braces to be not less
than 45 decrees to the horizontal. Sec. 2518(Fi)
p( Show 1/2" minimum clearance between top
plate of interior partitions and bottom
chord of trusses. (To ensure loading
will be as designed.)
7. Show double top plate with minimum 48"
lap splice. Sec. 2518(g)4
".I'D. Show nailing will be in compliance with
Table 25-P.
Provide fire stops between stories, between NOTES: top story and roof space, at ceilings
%Ther, unusual conditions or frost conditions are found, footings and and floor levels in interior and exterior foundations shall be as required in Section 2907(S). walls, in mansard roof or eyebrow so no The ground under the floor may be escalated to the elevation of the concealed or furred space is greater than top of the footin. 10' horizontally or vertically, between
stair stringers at top and bottom and
Show foundation sills to be pressure treated, between studs along and in line with
stair run adjoining stud walls and partitions, or equal. Sec. 2517(c) 3. at perimeter of sliding door pockets,
13.
Show foundation bolt size and spacing. between chimney and wood frame using metal
Sec. 2907(e) or incombustibles for the fire stop and
Specify size. ICHO number and manufacturer at other places that could afford passage
f7 of power driven pins. Show edge add end of flame. Sec. 2517(f)
distance and spacing. Sec, 306(f) Show stud size and spacing. Maximum allow-
J
down anchors on foundation plan. Sec. 2312(f)
135 Show size, imbedment and location of hold able stud heights: 2"x4'8 16" is 14';
3"x4"&2"x6'9 16'o.c. is 20. Sec. 2518(g)2
:: Note on plan that hold down anchors must for glued laminated wood members shall )4 Note an A.I.T.C. Certificate of Compliance
e be tied in place prior to foundation inspection, be given to the Building Inspector prior Sec. 2312(f) to erection. Sec. 306(f)
Show adequate footings under all shear
connections. Sec. 2517(c) 4 V
walls. Sec. 2311(e)
than 1:10. Sec. 2907(c)
Detail all post to beam and post to footing
Show stepped footings for slopes steeper 17 . Specify nail size and spacing for all
shear walls, floor and roof diaphragms.
Indicate required blocking. Maintain Show minimum 18" clearance from grade to
bottom of floor joists and minimum 12" maximum diaphragm dimension ratios.
l4. Show minimum under floor access of 18"x 24". Provide truss details and truss calculations.
clearance to bottom of girders. Sec. 2517 ('rabies t,J.1C).
Show pier size, spacing and depth into 1J4' Show 3•x4" or 2'x6" studs in first story
94 / undisturbed soil. Table 29-A ;
)A
of three story building. Sec. 2518(f)
Sec. 2517 Y7.
,)) Show minimum under floor ventilation equa
&-!
to 1 1/2 sq. ft. for each 25 lineal feet Provide framing sections through
—
_/F t2ec'd.
Provide roof framing plan. Sec. 302(a)7
of exterior foundation with openings as
close to corners as practicable to provid
cross ventilation on at least two approxi
Specifllhdizes .i Section 302(a) 7
er ly opposite sides. Sec. 2517 or opening over
4' wide, Sec. 2518( I. FRAMING
Provide calculations for\I0J\4RAQ 4 / Show all joists, rafters, beams, and posts Lo Cn S nem Ouj 2" to 4" thick to be No. 2 Grade Douglas e\Ab1 iYV16 Fir-Larch or better. All posts and beams Section 302(a) 7
5 and thicker shall be No. I Grade Douglas . to tn as su ject to water splash and Fir-Larch or better. (Table 25-A-I) exterior locations, wood columns and posts
1
61
Show wall bracing. Every exterior wood shall be supported by piers projecting
Stud wall and main cross partition shall at least 2" above the finished grad, and
be braced at each end and at least every shall bear on a metal base plate or treated
25 feet of length with 1x4 diagonal wood unless the columns or posts are foun-
let-in brace or equivalent. Sec. 2518(g)S dation grade redwood or cedar. Sec. 2517(c)4
DEPTh OF
FOUNDATION
WIDTH TNICXNCSS BELOW
NUMBER TWICRNESS OF OF OF NATURAL
OF FOUNDATION WALL FOOTING FOOTING SURFACE
STORIES (inches) (Inches) (inches) OF GROUND
AND FINISH
CONCRETE UNIT
MASONRY .
GRADE (Iachu)
1 6 8 12 6 12)
2 8 8 15 7 18
3 10 10 18 8 24
Show location of attic access with minimun Show access to the attic or under floor size 22" x 30". Sec. 3205 furnace to be minimum 30 inches by 30 ?1 4. Show draft separation for attic areas inches. Sec. 708 709 WIC
in excess of 3,000 sq.ft. Sec. 3205 74'. Note that passageway to the attic furnace
Mid
be unobstructed and have continuous Y Show draft separation. for space between solid flooring not Less than 24 inches dropped ceilings and floor above in excess wide. Sec 708 UMC of 1.000 sq.ft. Sec. 2517
1i. Specify plywood grade and panel indenti- Show permanent electrical outlet and
lighting fixture controlled by a switch
for the attic furnace. Sec. 708 (INC
fication index. Table 25-.!
When roof pitch is less than 3:12. design 1. Show details to comply with Section 09 ridge as a seam. Sec. 2518 (t) for furnace under the floor. Section 708
for attic furnace, or Section 710 for
7 Wood sheer walls shall not be used to roof or outside furnace. resist horizontal forces contributed by 4. Note on plan, gas vents and non-combustible masonry in buildings over one story in piping passing through three floors or height. Sec. 2516(b) less shall be effectively draft stopped Gypsum lath and plaster, gypsum sheathing at each floor or ceiling. hOC Sec. 1706(a)6 board and gypsum wallboard shall not be
used in vertical diaphragms to resist K. ELECFRICAL. (National Electrical Code) forces imposed by masonry or concrete All wiring shall comply with the National Electrical construction. Table 47-I
If cripple wall studs are less than 14",
framing shall be solid blocking. Sec.2518(g)6 Note on the plan the amperage of electrical
Cripple wall studs exceeding 4 feet in If the electrical installation is more
service.
height shall be 3 inch by 4 inch or 2 an 200 amperes, show panel location inches by 6 inches when supporting 2 stories, and orovide a single line diagram and Sec. 2518(g)6 load calculations including: /. Show plywood sheathing over exposed eaves, a. Wiring method employed.
b. Sizes of all conductors, switches. or other weather exposed areas, is exterior
circuit breakers, fuses, and conduits. grade. Sec. 2517(g)
C. Approximate length of service feeders. Show a weep screed at the foundation plate d. Provide plot plan showing services, tine on all exterior stud walls to be all panel locations, circuit arrangement stuccoed. Sec. 4706(e) and load distribution on panel busses. /4. Provide an approved waterproof building e. Provide typical panel schedule(s).
paper under wood siding. Sec. 1701(a) Dwellings require minimum 100 amp service. v. Specify an approved flashing for exterior 2.2' Show location of all electrical receptacles. openings and parapet walls. Sec. 3208 Electrical receptacle locations and/or Y Show corridor width to be minimum 36". spacing is not adequate in Sec. 3304(b)
Specify truss layout for 30 x 30" attic
. access
,
3.26':' At least one receptacle shall be installed
outdoors, in basements and attached garages, ' Ridges. hips, and valleys shall be at other than laundry outlets. Art. 210-25(b) ,least
Provide metal straps across ridge beam
Note "UFER" ground to be provided (NEC).
one size larger than supported Show minimum dwelling lighting (NEC rafters. Sac. 2518(h) 3
Art. 210-26(a) and GFIS in garage, baths
and outdoors. NEC Art. 210-8(a). and rafters.
Art. 250-81 J. MECHANICAL
All heating, ventilating, and cooling system
i: and appliances shall comply with the Uniform
anical Code.
L. PLUMSING (Uniform P1uinbin Code) Show the size, location and type of Y all heating and cooling appliances or systems All plumbing shall comply with the Unifrom
Show source of combustion air for furnace Plumbing Code.
will comply with Chaper 6, U.M.C. 2S. Show water heater size, type and
location on plans. Every dwelling unit shall be provided with
2)4'. Show method of providing combustion air heating facilities capable of maintain-
feet above the floor in all habitable 2 . Fuel combustion water heater shall not be
ing a room temperature of 70 P. at 3 to fuel burning water heater. Sec. 1307
rooms. Show basis for compliance. UBC installed in bath or bedroom or in a closet Sec. 1211 opening into bath or bedroom. Sec. 1309
. Show minimum 30" deep unobstructed working 2)4. Provide adequate barrier to protect water
/3
~
space in front of furnace. heater from vehicle damage. Sec. 1310 4
,
. Note on plans, clearances to be per manufac- 2 . Show 'r and P valve on water heater and
2'
turers listing. Sec. 704 (INC show route of discharge line to exterior
Furnace shall not be installed under any Sec. 1007(e)
stairway. Sec. 704 (INC Provide dryer vent to outside. (INC
7'. Furnace shall not be installed in any Sec. 1903
bedroom, bathroom, closet, or in confined 271. Note on the plan that hose bibbs and lawn space with access only through such room, sprinkler systems shall have approved unless specified as direct vent appliance, backflow prevention devices. Sec. 1003 enclosed furnace or electric heating appliance.
ec. 704 (INC Shower stall shall accomodate a 30"circle
and have a minimum floor area of 900 sq.in. "Show ICBO approval for prefab fireplace UPC 909(d)
S
,,, 'nd provide approved installation instructions 1 a site.
-----.--.- _jJ 11\).2 .lMVfl_Jl0YI 'r"
L)
'9
11.
MOrSE CNSUr.Tt0N (CUPtEX!SP
Show it3Ll5 of duplex ogmaOfl .partyl w3115
and 1Oor. :sjLino .iasunolis to ICniCVe
i Sound 7r3nSMLSSLOn .251 5T11 racing
in slli OE 50 .lectU(c ifid n Cmpact
cnoulaciofl Class 111i1 r3tinq on elour.
ceiling of SO licintas. Title 23
Show now penetration of asseast em for I
piping. electrical devicas. recessed C3bfleS.
b&cntuS5. soffits. or heating ventilating. 2J4.
or exhaust ducts snail be sealed. l ined- cc insulated to saincain required sound
2$. erans.,.zaion rating. Title 23
Provide insulation in wails and ceiling to achieve STC of SO between garage and 2G.
ivigtg area if garage USS IS not centre I Lid
by resident Title 23.
/ Not at the exterior wall fireplace Fir
e
.ptac. to have minimum six square
inches of outside air; to have glass
or metal door covering the entire opening
of the firebox; to have tight-fitting
damper with readily accessible control
and should not have a continuous burning
pilot light.
Note ducts shall comply with Chapter 10, 1976 (iNC and shall be tightly sealed with mastic or tape.
Note at the water heater location water
heater to have wrap of R-12 external
insulation.
Note, where water heater is in unconditioned space, the first five feet of outlet pipe to have 11-3 wrap.
Note all circulating hot water pipes in unconditioned spaces shall be insulated.
Note that all gas fired heating and cooling appliances, showers and faucets
shall comply with the Energy Efficiency
Standards.
Show, at bath and kitchen, that the general lighting shall have an efficiency
of not less than 25 lumens per watt i.e. florescent.
Note that heating or cooling systems (except heat pumps) shall have an automatism thermostat with mechanism which can be
manually programmed to automatically
set back the thermostat set points for at least two periods within 24 hours.
Show the size, type and location of the space heating (or cooling) system and provide energy calculations if the output STU/Hr. exceeds 45,000 STU/Nr. output.
p0• Show mats and aL for ?AU and water nester are an State approved list.
Outdoor pools -4LCft fossil fuel heac.ri
require pool covers as well an other energy saving devices such as time ciac*a, etc. .20-L4041
0. NXSCLLANEOUS )di. Show a minimum 2 air space and flashing
I' between planter and building walls.
Sec. 2517(e)
Specify material to be used under the
er tile. Sec. 1707(a) show
(ERG1 CCIISERVA?!ONi Pt.... Read
New State Mandated Regulations
(Calif. Adam. Code) became effective June 16. 1983 and require that the design satisfy one of the alternative energy packages see attached packages A. B. C. 1, 2, 3, 4 and AS 163). The
law also requires that many mandatory
cons.rvation items be satisfied.
A44/47 is in Zone '7
Copies of the Residential Energy
Conservation Manual any be obtained franz Publications Unit, California
Energy Commission. 1111 Howe Ave. I-50. Sacramento, California 95825. (Tel.
(916) 920-6216)). California Building
Officials also maintain a telephone
90t1ine between 10:00 A.M. and Noon
and 1:00 P.M. to 4:00 P.M. at (916)
436-3823.
Show on the title sheet of the plan.. the alternative energy package that
was selected i.e. A. B. C. 1, 2. 3.
4. or AS 163 to show compliance, and provide calculations and other data,
appropriate to that selected package.
The responsible designer should sign a statement, on the plan title sheet. The design submitted substantially
conforms to the Energy Regulation.
for Residential Buildings*.
Show the R value for the walls and
ceiling and related area..
Note that the insulation used shall
Comply with California Quality Standards.
Note the insulation installer shall
post a signed certificate, in a conspicious
place in the building, stating the
insulation complies with Title 24, Chapter
2-53 and Title 20. Chapter 2. Subchapter
4, Article 3.
Note doors and windows, including skylights.
between conditioned and non-conditioned space shall be fully weatherstripped.
Note on the framing plan that weather-
stripping. caulking or sealants must
be used to limit filtration in the
building envelope at the following locations,
Exterior 30jnt3 around windows and door
frames; between wall sole plates and floors.
and u.twv.n exterior walL paneLs;
penetrations in walls, ceilings, and floors for plumbing, electricity, and
gas lanes; opinings in attic floors;
and all other openings in the building envelope.
Note that doors and windows to be certified
and Labeled as complying with the Energy
Regulations.
t. Note fans exhausting air to have back
draft dampers.
('L' -10
l t2hlQ/t1c1 I tq'o4c
7.1" Specify lath and plaster to comply with
Chapter 47, USC.
394. Two 3/4 copper pipes must be installed
from water heater Location to convenient
location of future solar panels (City Ord.)
Provide sleeves (roof jacks) in roof for 7 two future 3/4' copper pipes to ci.nvenient
location of future solar panels (City Ord.)
3(. Note that solar water piping is to be insulated / in areas that are not heated or tooted.
(City Ord.)
0 Building plans are substantially correct and complete.
By'
Date:
Building plans would be substantially correct and complete is minor correcions are made at counter.
lay
P
an-ate:_
uilding plans require major corrections and osiplete plan recheck, by plan check ngineer, is requd.
y, •.J,'vl
_______________________
If
you have any questions rarding
this plan check, please call
at VCoC)
We would also be pleased to meet with you, at no charge, if additional assistance Is needed.
287
71
ACCEPTABLE HANDRAIL DETAILS
(Section 3306 0)]
1'/to2 1W 11/4"1W
MIN
.
.:IN..
1'/E toT
ri 3WMAX. -
NOT
ACCEPTABLE
Section; 3306 1982 EDITIONS. UNIFORM BUILDING CODE
(j)Hándrails. Stairways shall have handrails on each side, and every stairway
required to be more than 88 inches in width shall be provided with not less than
one intermediate handrail for each 88 inches of required width. Intermediate
handrails shall be spaced approximately equally across with the entire width of the
stairway.
EXCEPTIONS: I. Stairways 44 inches or less in width and stairways serving
one individual dwelling unit in Group R, Division 1 or 3 Occupancies may have one
handrail, except that such stairways open on one or both sides shall have handrails
provided on the open side or sides. : . ... •
Private stairways 30 inches or less in height may have handrails on one side
only. ..
Stairways having less than four risers and serving one individual dwelling unit
in Group R, Division I or 3. or serving Group M Occupancies need not have
handrails. . . . .
Handrails shall be placed not less than 30 inches nor more than 34 inches above
the nosing of treads.. They shall be continuous the full length of the stairs and
except for private stairways at least one handrail shall extend not less than 6 inches
beyond the top and bottom risers. Ends shall be returned or shall terminate in
newel posts or safety terminals. .
The handgrip portion of handrails shall be not less than 11/4 inches nor more
than 2 inches in cross-sectional dimension or the shape shall provide an equivalent
gripping surface. The handgrip portion of handrails shall have a smooth surface
with no sharp corners.
Handrails projecting from a wall shall have a space of not less than 1 ½ inches
between the wall and the handrail. . . . •
ACCEPTABLE HANDRAIL DETAILS
[Section 3306(j)]
NOTE:
OTHER SHAPES MAY BE ACCEPTABLE
IF THEY PROVIDE AN
EQUIVALENT GRIPPING SERVICE. SEE THIRD PARAGRAPH OF
SECTION 3306 Ii).
SIQUIRtDWUTH OT RUN SHALL
SHALL 81 PRO mID I tillS LOCATION
LStC1lO 3305 (c)1
- P.(QUIRID WIDTH OF RUN SHALL
SHALL Of FROVIULO IN TillS LOCATION
ISCC1ION 330$ (c)i
J INCHES 0
UNIMUM
.t. NOTt:HANORAI S NOT
SHOwNIOsCLA TV
MAN VIEW
LIMITATION: APPLIES 10 2-3 OCCUPANCY
AND PRIVATE STAIRWAYS IN R-1 OCCUPANCY.
WINDING STAIRWAY
ISECT ION 3303 (d)I
IKE RRCEST TREAD WIOflI
OR RISE IILICHI WITHIN ANY
PLIGHT OF STAIRS SHALL
NOT E XCEED THE SMALLEST
IYMO!1 THAN '. INCH.
1UCTION 3305 (c)J
O
INCHES MINIMUM
fSLCTION 3305 (c)J
NOTE: HANDRAILS NOT SHOWN
FOR CLARITY
,)c
-
AD
tllr
. ±
STAIRWAY WIDTH
DICTION 3305 (bfl PLAN
(I%At STAIRWAY
C1 ION 3305 Cr3)
PLAN VIEW KNOTE1
NOR At I S
NOT 5110W N log CL
STAIRWAY WIDTH LIMITATION: APPLIL S TO R.3 OCCUPANCY
[SECTION 3303 (b)l AND PRIVATE STAIRWAYS IN .1 OCCUA
WINDING STAIRWAY
(SECTION 3305 (di)
- -MUM 9'4NcpI
RISE ETWt.t4 TE L'
X
\
_Af r
CIPY(R SUPPOIT
COLUMN
NOTE: HANDRA-
NOT SHOWN
FOR CLARITY
LIMITATIONS 1. LIMITED TO SERVING AS MT FOR
SQUARE lilt MAkIiU%I.
3. APPLIFS TO R-3 OCCUrINCY AND
PRIVATE STAIR% ATS IN £-T 0C11JFANC
SPIRAL STAIRWAY
(SECTION ])us ((A
The above are some typical stairway layouts with applicable code sections indicated!
••:,?
#'ymv 1W ('T?jfl A 4 flASSjJSJfl&I
Table 7. Alternative Component Packages, Climate Zone 7
Building Measure
Package Designation
A B LC D E 1 1 2 1 3 4 56
INSULATION R-VALUE MINIMUM
Ceiling 19 30 19 .30 30 30 19 30 19 30 19
Wall 11 11 I1. 11 11 11 11 11 11 11 11
heavy" Wall 2.5 2.5 2.5 NA NA 2.5 2.5 2.5 2.5 2.5 2.5
"Light Mass" Wall . 4.0 3.5 3.5 NA NA NA NA NA NA NA NA
Slab Floor Perimeter MR 7 NR MR NA NR MR Nit MR 7 MR
Raised Floor . 11 11 11 NA 19 MR MR 19 19 11 11
A.rr1c3 -. MR NR MR REQ REQ REQ Nit REQ MR NR Nit
GLAZING . -
Maximum U-Value 1.1 .65 1.1 .65 .65 .65 1.1 .65 1.1 .65 .65
Maximum Total Area % Nit 14 14 20 20 20 24 20 24 MR MR
Maximum Total Nonsouth
Area 9.6 NA NA NA NA MR MR Nit MR 8.4 9.6
Minimum Total South
Area 6.4 NR MR Nit MR Nit MR MR MR 5.6 6.4
SHADING COEFFICIENT
South-facing Glazing MR MR MR MR MR Nit Nit MR Nit MR MR
West-facing Glazing MR MR MR .36 .36 MR MR Nit Nit MR MR
North-facing Glazing Nit MR MR Nit Nit Nit MR Nit Nit MR MR
East-facing Glazing Nit MR MR MR Nit Nit MR Nit Nit Nit Nit
LHERMAL MASS EQUIVALENT
.Z Slab Floor Exposed7i8 50 MR MR 25 5 25 25 20 15 Nit 50
INFILTRATION CONTROL
Continuous Barrier NR MR MR' MR Nit Nit . MR MR MR Nit Nit
lectrical Outlet Plate Nit NR MR Nit Nit MR MR MR MR MR Nit
Gaskets
jr-To-Air Heat Exchanger NR Nit MR MR MR MR MR. MR Nit Nit Nit
;PACE HEATING SYSTEM
Gas Furnace Seasonal
Efficiency Z MIN MIN MIN MIN MIN HIM MIN MIN MIN
Heat Pump ACOP 2.5 2.5 2.5 2.5 2.5 2..5 2.5 2.5 2.5
Electric Resistance" NO NO NO NO NO NO NO NO NO YES YES
PACE COOLING SYSTEM
A/C or Heat Pump SEER
!ATER HEATING SYSTEM
Gas, Heat Pump or Solar
with Any Backup REQ REQ REQ REQ REQ REQ REQ REQ
Solar with Gas Backup , REQ REQ REQ
Appendix B
3-9
C-70 ACP . . . . . . S.
-
Table 17. Notes for Tables 1 through 16, Page 1 of 4
LEGEND: NR Not required, N/A Not applicable, REQ Required, MIN - Minimum efficiencies required by Section 2-5306 of the
regulation. NO - Heating system type not allowed, YES - Heating system type allowed.
3. Whenever an attic is required, it must cover at least three-quarters
(3/4) of the ceiling area over conditioned space and be vented.
In alternative component packages which require thermal mass (other than
Package A), the specified percentage of mass must be directly exposed to
the conditioned space. To determine the floor area directly exposed to
the conditioned space. To determine the floor area, count only the first
floor •in conditioned areas. Uncarpeted first floor areas, such as
linoleum or tiled entry ways, kitchens, bathrooms, and utility closets
may all be counted towards this requirement.
Thermal mass required for Packages E,1,2,3 and 4 must be either
equivalent to a slab floor covering one-fourth (25 percent) of the floor
area with a thickness of at least 2 inches and a volumetric heat capacity
of 28 Btu/ft3 °F (see below for surface area of materials examples) or
provide the minimum total mass capacity listed in Table 17 of Appendix A
(use the Point System to calculate the mass for other materials).
4" brick Concrete block 90 pcf Concrete block 140 pcf
Climate Slab exposed block density, block density, solid
Zone Floor Z one side grouted grouted
• 4.1 6" 411
• 6"
15 21 18 17 14 13
20 28 24 22 18 18
7 25 35 30 28 23 22
11. For Packages 5 and 6 electric resistance and radiant heating systems
shall have two or more separately controlled zones in each dwelling
unit.
mass, etc., are still regarded as the same model. Different
models are not be grouped together for averaging.
Builders who elect to average must apply for permits for all
buildings in an averaged group on the same day, and each
application must indicate the group to which the averaging
approach is applied. The builder demonstrates compliance by
using either the Point System. or any other approved calcula-
tion method, such as a certified computer program (see
Chapter 4), to show that a simple arithmetic average of the
energy performance of all buildings or units In the group
meets the standards' energy budget. When the buildings are
offered for sale, builders must also notify potential buyers
that -compliance with the energy standards used averaging and,
that the performance of a particular home relative to the
performance standard is available upon request.
New Packages--Builders may also use new packages D and E
enacted by AB 163 instead of Packages A, B, and C In the
standards. The approved packages for each climate zone are
in Tables 1 through 16 of Appendix B.
Custom Budgets--AB 163 also allows builders to develop and
use their own selection of measures, provided such designs
result in the same energy performance as the new packages in
AB 163.
Future Compliance Methods
The Commission will certify additional computer programs
which meet specified requirements and may certify additional
alternative component packages or simplified calculation
methods, including hand held calculator techniques. Contact
the Commission's New Building and Appliance Efficiency
Office for detIlls on submitting a method for
How the Code Applies to Additions
The code only applies to additions or alterations that
increase the heated or cooled space of a building.
Additions must either (1) meet the Insulation, glazing U-
value, and shading requirements of Package A for the appro-
priate climate zone and have a glass area less than or equal
to 16 percent of the addition's floor area plus the amount
of existing glazing area covered up by the addition, or (2)
meet the energy budget for the appropriate climate zone by
using the point system or a Commission certified computer
compliance method. Energy efficiency improvements may be
made to the existing structure and used to offset energy
consumption of the addition. The area weighted average
energy consumption of the improved existing building and the
addition must not be greater than that of the unimproved
Introduction
C-60 REM .-.-----
1. 4-i
-
/ existing building plus an addition which complies with the
f budget.
Additions must also meet the mandatory requirements for wall
and ceiling insulation, infiltration control, vapor
barriers, duct insulation, and lighting. The specific
requirements for the mandatory measures, Package A, and the
performance methods, as they apply to additions or altera-
tions can be found in Chapters 2, 3, and 4, respectively.
New space heating and cooling equipment installed in con-
junction with an addition must meet sizing and efficiency
requirements. New water heating equipment installed in con-
junction with an addition must meet efficiency requirements
and either (1) be wrapped with an R-12 blanket or (2) have a
total internal and external insulation of R-16 or greater.
ts
The administrative regulations require builders to document
fully for the local enforcement agency how they comply with
the new standards. Designers and building officials may use
compliance forms and work sheets prepared by the Commission
to document or verify that a building meets the standard and
other code requirements. See Appendix D for instructions
and one copy of each of the forms. You may reproduce the
forms for your use.
Form 1, Mandatory Measures Checklist, may be used to check
compliance with Title 24, §2-5352, Mandatory Features and
Devices, 52-5306 and 2-5307 regarding equipment efficiency,
and 62-5303 to 2-5305 regarding insulation quality.
Form 2, Building Design and System Summary, lists features
that affect a building's energy performance. It may be used
to document compliance for the building and system design,
regardless of the compliance path chosen. A calculation
work sheet is *also provided to assist the designer in
completing Form 2.
Form 3, Average U-Value of Assembly, is used to calculate
the average U-value of ceiling, wall, and floor assemblies
when insulation in any of these areas is not at a uniform
level throughout. These values are used for performance
calculations in the point system and may be used in docu-
menting compliance with mandatory insulation levels or
component package "requirements.
Form 4, Insulation Certificate, may be used by the insula-
tion contractor and/or builder to certify that the installed
insulation meets levels required by the standards. A
certificate such as this must be posted in the building, and
a copy should be filed with the building department.
Calculation Work Sheet, may be used to assist the designer •
in completing Form 2. • •
• Introduction
1-7
C-60 RECN frO h
Dates_____
Prepared bys
VALUATION AND PLAN CHECK FEE
Bldg. Dept.
Esgil
PLAN CHECK NO. 455--42e57
BUILDING ADDRESS
APPLICANT/CONTACT OL1soN PHONE NO.43'- I74I
BUILDING OCCUPANCY _,2-3 ,4'i-7, DESIGNER PHONE
TYPE OF CONSTRUCTION __ CONTRACTOR PHONE /1
BUILDING.PORTION BUILDING AREA
-
VALUATION
MULTIPLIER
VALUE
Air Conditioning
Commercial
Residential
Res. or Comm.
Fire _Sprinklers
Total Value
Fee Adjusted To Reflect DEnergy Regulations (Fee x 1.1)
0 Handicapped Regulations (Fee x 1.065)
Building Permit FeeS :
Plan Check Fee 5
C0NHENTS
8/4/82
CHECK NUMBER 1~'R2_ ADDRESS 72S cOCt€i,(__DATE 8'1'3
TYPE OF STRUCTURE /2'.-V--'—I'--4! -. ZONE:__________
SCHOOL FEES: SAN DIEGUITO
ENCINZTAS___________________
CARLSBADAIN SAN MARCOS
-
% COVERAGE_____ ______________________ REQUIRED SETBACKS
-
BUILDING HEIGHT OY FRONT_________________
_.IING:
FENCES/WALLS SIDE_______
TWO CAR GARAGE ot' REAR
-
COMMENTS:
REDEVELOPMENT APPROVAL REQUIRED:
.. .
-
cr
Su lu=j LANDSCAPE PLAN COMMENTS:
ENVIROENTAL REQUIRED
ADDITIONAL COMMENTS:.\CtO...G
OK TO ISSUE: DATE: ;~70-K--T-0 FINAL: - DATE: __-___ ! -
ENGINEERING, LEGAL DESCRIPTION VERIFIED?
__________ A.P.N. CHECKED?..
I
PARK IN LIEU
-IMPROVEMENTS:
-- . E.D.U: 31A
SEWER: .
LATERAL: A DRIVEWAY:
_________________
GRADING PERMIT:Alfi
_________..•.-
DRAINAGE:
EASEMENTS: Ala
;.
ADDITIONAL COMMENTS:
LLJ
[71
OKTO ISSUE: 2/ : DATE:
* ENGINEERNGJN ECT-iON REQUIRED: . . . .
PUBLIC WORKS INSPECIOR:______________________________________________________
FINAL OK: DATE:
* IF THIS ITEM IS NOT CHECKED, BUILDING DEPARTMENT WILL MAKE ALL INSPECTIONS
(DRIVEWAYS, CURB CUT,. DRAINAGE, ETC.)
APPLICATION FOR COASTAL DEVELOPMENT PERMIT
APPENDIX B
LOCAL AGENCY REVIEW FORM
tCTION A (To be completed by applicant)1
Applicant DBC1 3bI1L/SciJ
Project description &0 1 LLjKgmweL) At:t -tF- - &cr Th11tss
Location 272- .- 77
Assessor's Parcel Number
ISECTION B (To be completed by local planning or building inspection department)I
Zoning designation du/ac
General or Community Plan designation du/ac
Local Discretionary Approvals
Proposed development meets all zoning requirements and needs no local permits
other than building permits.
0 Proposed development needs local discretionary approvals noted below.
Needed Received
O 0 Design/Architectural review
O 0 Variance for
o 0 Rezone from'
o 0 Tentative Subdivision/Parcel Map No.______________
O 0 Grading/Land Development Permit No.________________
Q 0 Planned Residential/Commercial Development
0 0 Site Plan Review
o 0 Condominium Conversion Permit
0 0 Conditional, Special, or Major Use Permit No._____________
O 0 Other________________________________
CE-QA Status
CZ, Categorically Exempt - Class IteinJ53CI
0 Negative Declaration Granted_____________________
Environmental Impact Report Required, Final Report certified_____________
Prepared for the City/County of (ac\bao1 by t.ic)3
Date (, Title4
1'
I...
ROBERT GIBSON JOHNSON
- ROBERT 0. BANMON
WELLS K. WOHLWENO
WILLIAM E.JOHNSTON
GILBERT F. NELSON
HARRY 0. MILLER
HARRY A. OLIVAR
HARRY C.TAUO
KAREN 0. CUTTS
- • LAW OFFICES OF
JOHNSON. BANNON.WOHLWEND & JOHNSTON'-
SUITE 3320 CROCK ER BANK PLAZA CENTURY CITY OFFICE
GUI WEST SIXTH STREET . • SUITE 435 GATEWAY EAST
LO 1800 AVENUE OFTHE STARS, ANGELES. CALIFORNIA 90017 LOS ANGELES 90067
-. -. TELEPHONE 624-6253 (213) 552- 0175
April 5, 1978 R E
APR -71978
Mr. Dave Abrams
. CITY OF CARLS8AD Planning Department . Planning Department City of Carlsbad .
Carlsbad,, California 92008 . . .
Re: Control No. E6778/E0016
Emergency Permit
Dear Mr.Abrams: .
. Please find enclosed the following:
.
1. Emergency Permit dated March 7, 1978
. issued by the San.Diego Coast Regional Commission
covering the premises at 2723-2751 Ocean Avenue, • Carlsbad.
...
. .. . .
2. Application For Permit to the San .D.igo
Coast Regional Commission executed by Mrs. Johnson
and the undersigned which has been filed with the
..'
-Commission. . -• . . .
.
.
. .
I believe that you will find both of these
instruments self-explanatory. . .
Further to our conversation of yesterday,
will you kindly refer to Page 7 of the Application and
in particular to question 36 and also to subparagraph
3 of Section VI and advise the appropriate responses
to said items together with such action, if any, required
by the applicants in connection therewith..
Your courtesy in this connection will be very
much appreciated. . . ••
RGJ:tw
Enclosures . •
cc: • Charles Damm • Franks: M. Bell, Robert Bryant, Fred Z. Havens, Jr.
Robert W. Watson . .. -
4 7
Robert C
STATE OF CALIFORNIA—CALIFORNIA COASTAL COMMISSION -. EDMUND G. BROWN. JR.. Govrn6r
SAN DIEGO COAST REGIONAL COMMISSION .
ROBERT C. FRAZEE
6154 MISSION GORGE ROAD. SUITE 220 . . . -
Chairman.
SAN DIEGO. CALIFORNIA 92120—TEL. (714) 280-6992 . VIRGINIA BRIDGE
- - Vice Chairman
. . .- .-. E!RGCY PE -T JEFFERY D. FRAUTSC
• - Representative to the
ontrol No: . E6778/016 ' .• .
California Coastal Commisi
. F ..
Bruce.H. Warren
ate: ••,• March?, 1978
I
. • .
Exetive o;reClof
imlicants: " 'Robert W. . Watson Robert Bryant . ... . . ..
• Frank M. Ben . Fred Z. Havens, Jr.
Nature of Emergency Bluff is being eroded due to high surf damaging or eridengering
stairs, patios and sheds located on the bluff. . .
Location 2723-2751 Oceari Avenue, in. Carlsbad. 'Lots 30-38, Block A of Hayes Land
Company Addition. . .
Work Proposed Temporary placement of rock rip rap along 'the, toe of the bluff to. prevent
further damage due to wave erosion and scouring during tagn sun' conditions.
Staff verification of facts, existence, and nature of emergency Site inspection,
discussions with agent for the applicants, review of similar emergency permit issued
fo'r property to the south (ref.. F6584/EO06) .
.
TO: Robert GLbson Johnson
Johnson, Bannon, 'Wohiwend and Johnston
Suite 3320 Crocker Bank Plaza
611 West Sixth St.
LOS Angeles, CA. 90017 -
You are hereby granted an emergency perthi.t. This is based on an administrative
determination that this emergency poses an immediate danger to life, health, or
property or to maintain public service. This permit is subject to the following
terms and. conditions:
L. That all the material used in constructing £he terrporary reaietment will be removed, alort
with any other material placed at the site by the applicant, .by July 1, 197 unless
........application for a permit for a permanent solution to the problem has-been filed by the
applicant with the San Diego Coast Regional Commisibri art or before the July 1st date.
. That no material 'shall be removed from the beach for backfill, except material excavated
from the footing trench for the authorized revetment.
EERGECY PERMIT 136778/BJ016 .- Page TWO
.9 ..
Within 5 working days after receipt of this emergency permit, the permitte
shall deliver to the Executive Director a regularly completed application
form for development within the Coastal Zone Boundary.
;rxKuuce*4a
yours,-.- ..-.-
Executive Director
. San Diego Coast Regional Commission
By: Charles D m
•.
EMERGENCY PERMIT Control Number F6778/)O6
DIRECTIONS_TOPERMtTTEE: .
Permittee. is to execute below and return copy of this permit to the San Diego
Coast Regional Commission within 10 working days following date of issuance,.
I have read and understand the terms, conditions and limitations of this permit
and agree to abide by them.
Control Numb erF6778/EJJ016 Date •4-4-78 • 'çIj rw1ra-u
Signature o Permitt
1200 ELM AVENUE TELEPHONE
CARLSBAD, CA 92008.1989 (619) 438-5525
Citp of CarLbab
BUILDING DEPARTMENT
May 2, 1986
Mark Oleson
Oleson Construction Co.
2040 S. Ditmar
Oceanside, CA 92054
2725 OCEAN AVENUE: CORRECTION LIST
The three hundred (300) square fee of added redwood decking with
thirty-six-nch wide stairs will have to be approved by the Coastal
Commission as this portion of construction was not shown on the
original approved plan. .
Final of project and setting of electric meter will be granted upon
approval of the Coast Commission.
TONY MATA
Principal Building Inspector
TM:hmj