HomeMy WebLinkAbout2726 Inverness Dr; ; CBR2016-0487; PermitPrint Oat~: 11/15/2017
Job Address:
Permit Type:
Parcel No:
Valuation:
Occupancy Group:
# Dwelling Units:
Bedrooms:
Project Title:
2726 Inverness Dr
BLDG-Residential
20811.11900
$107,591.50
City of Carlsbad
1635 Faraday Av Carlsbad, CA 92008
Residential Permit
www.carlsbadca.gov
Work Class: Addition Status:
Lot#: Applied:
Reference #: Issued:
Construction Type: Finaled:
Bathrooms: Inspector:
Orig. Plan Check #:
Plan Check #:
Description: WILLMON: ADD ITION 260 SF TO BEDROOM/BATH & 265 SF DEN (TOTAL 525 SF) // REMODEL 400 SF KITCHEN/
BEDROOM/LIVING ROOM
Applicant: Owner:
STEVEN NOEL ARCHITECT MATIHEW WILLMON
STEVEN NOEL 2726 Inverness Dr
CARLSBAD,CA 92010
760-535-7847
BUILDING PERMIT FEE $2000+
BUILDING PLAN CHECK FEE (BLDG)
ELECTRICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL
GREEN BUILDING STANDARDS PLAN CHECK
MECHANICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL
PLUMBING BLDG RES IDENTIAL NEW/ADDITION/REMODEL
SB1473 BUILDING STANDARDS FEE
STRONG MOTION-RESIDENTIAL
SWPPP INSPECTION FEE TIER 1 -Medium BLDG
SW PPP PLAN REVIEW FEE TIER 1 -MEDIUM
Total Fees: $1,924.47 Total Payments To Date: $1,924.47 Balance Due:
Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter
collectively referred to as "fees/exaction." You have 90 days from the date this permit was issued to protest imposition of these
fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the
protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section
3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their
imposition.
You are hereby FURTHER NOTIFl:D that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection
fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this
project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the
statute of limitation has previow;ly otherwise expired.
Permit No: CBR2016-0487
Closed -Finaled
12/29/2016
02/10/2017
PB urn
$0.00
$654.40
$458.08
$66.00
$166.00
$92.00
$182.00
$5.00
$13.99
$232.00
$55.00
THE FOLLOWING APPROVALS REQUIRED PRIOR TO PERMIT ISSUANCE: 0 PLANNING D ENGINEERING
C_cityof
Carlsbad
Building Permit Application
1635 Faraday Ave., Carlsbad, CA 92008
Ph: 760-602-271 9 Fax: 760-602-8558
email: building@carlsbadca.gov
www.carlsbadca.gov
SUITEI/SPACEI/UNIT#
0 BUILD1NG O FIRE
APN
2.0B -\ I I -0
# OF UNITS # BEDROOMS # BATHROOMS TENANT BUSINESS NAME
DESCRIPTION OF WORK: Include Square Feet. of Affected Area(s) (. 1:j ]_ ~ ~ .
{2£.s 1ot::..rJ~L ~ r'IOOif!!1 A-~o,·p Q..1 \ ~-~ cf 2.&S S"r--) 1 /J(.,:,,0 ;--z.f w it--1eov> s ,
\2-lMoQtl-t.--O "-ifUIE-i-l, A.po,nl\--l~L {;1v1.J1::::r" Sfo.L.t, ~£oµe,M + \3,/ ..... N 1ut:>t--1 .
GARAGE (SF) 4Ds
DESIGN PROFESSIONAL
ADDRESS ADDRESS
CITY STATE ZIP CITY STATE ZIP
(.A crz...o \o
PHONE FAX PHONE FAX
EMAIL EMAIL
STATE LIC.# CLASS CITY BUS. LIC.#
C. GROUP
(Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, Improve, demolish or repair anl structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law [Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code} or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500)).
Workers' Compensation Declaration: I hereby affirm under penally of petjury one of the following declarations: 0 I have and will maintain a certificate of consent to self.insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. D I have and will maintain workers' compensation. as reQuired by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy
number are: Insurance Co. Policy No. Expiration Date---------
~section need not be completed if the permrt is lor one hundred dollars ($100) or less. LJ Certificate of Exemption: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of
California. WARNING: Failure to secure workers' compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars (&100,000), in
addition to the cost of compensation, damages as provided for in Section 3706 of the Labor code, interest and attorney's fees.
2S CONTRACTOR SIGNATURE DATE
I hereby affirm that I am exempt from Contractor's Ucense Law for the following reason: D I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contracto(s
se Law does not apply to an owner ot property who builds or improves thereon, and who does such work himself or through his own employees, provided lhat such improvements are not intended or offered for
f, hcwever, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for lhe purpose of sale).
D
owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractors License Law does not apply to an owner of
property who builds or improves !hereon, and contracts for such projects wilh contractor(s) licensed pursuant to the Contractors License Law).
I am exempt under Section Business and Professions Code for this reason:
1. I personally plan to provide the major labor and materials for construction of the proposed property improvement. 0 Yes 0No
2. I (have I have not) signed an application for a building permit for the proposed work.
3. I have contracted with the following person (firm) to provide the proposed construction (include name address I phone I contractors' license number):
4. I plan to provide portions of the work, but I have hired owing person to coordinate, supervise and provide the major work (include name I address I phone I contractors' license number):
he following persons to provide the work Indicated (include name I address I phone I type of work):
2S PROPERTY OWNER SIGNATURE 0AGENT DATE
Is the applicant or future building occupant required to submit a business plan/utely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the
Presley· Tanner Hazardous Substance Account Act? Cl Yes J,!"No
Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? Cl Yes Cl No
Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? Cl Yes Cl No
IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF
EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT.
I certify that I have read the appllcallon and state that the above lnfonnation Is correct and that the Information on the plans Is accurate. I agree to comply with all City ordinances and State ~ relating to building construction.
I hereby authorize representative of the City of Carlsbad b enter upon the above rnenlbned property !of inspection pul)X)SeS. I ALSO AGREE TO SA VE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD
AGIIINST ALL LIABILITIES, JUOOMENTS, COSTS AND EXPENSES WHICH MAY IN NNWAY ACCRUE AGIIINST SAID CITY IN COOSEQUENCE OF THE GRANTING OF THIS PERMIT.
OSHA: An OSHA perm~ is required !of excavations over '3CY deep and demolition or oonstructon of structures over 3 stories in height.
EXPIRATION: Every permit issued by the Buikling · provisons of this c.ode shall expire by limitaton and berome null and wid ~ the buikling or v.ork authorized by such permn is not CXllllmenced wthin
100days from the date of such permn or if the build" · by such permn is suspended or abanoooed at any trne after the v.ork is commeOO:ld !of a period of 100 days (Seeton 106.4.4 Unibrm Buikling c.ode) .
...@S' APPLICANT'S SIGNATURE DATE I 2-J._ q )t <o
' .
PERMIT INSPECTION HIST9,,RY REPORT (CBR2016-0487}
Permit Type: BLDG-Residential Application Date. 12/29/2016 Owner:
Work Class: Addition Issue Dato· 02/10/2017 Subdivision:
Status: Closed -Finaled Expiration Dato: 03/05/2018 Address:
IVR Number: 1141
Scheduled
Date
Actual
Start Date Inspection Type Inspection No. Inspection Status Primary Inspector
1111512017 11115/2017
November 15, 2017
BLDG-Final
Inspection
040527-2017
Checklist Item
BLDG-Building Deficiency
BLDG-Plumbing Final
BLDG-Mechanical Final
BLDG-Structural Final
BLDG-Electrical Final
Passed Paul Burnette
COMMENTS
MATIHEWWILLMON
2726 Inverness Dr
Carlsbad, CA 92010-6520
Reinspection
Passed
Yes
Yes
Yes
Yes
Yes
Complete
Complete
Page 4 of 4
'
, PERMIT INSPECTION HISTORY ~EPORT (CBR2016-0487)
Permit Type: BLDG-Residential Application Date: 12/29/2016 Owner: MATIHEWWILLMON
Work Class: Addition Issue Date: 02/10/2017 Subdivision:
Status Closed -Finaled Expiration Date: 03/05/2018 Address: 2726 Inverness Dr
Carlsbad, CA 92010-6520
IVR Number: 1141
Scheduled Actual
Date Start Date Inspection Type Inspection No. Inspection Status Primary Inspector Reinspection Complete
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-14 Yes
Frame-Steel-Bolting-Welding
(Decks)
BLDG-24 Rough-Topout Yes
BLDG-34 Rough Electrical Yes
BLDG-44 Yes
Rough-Ducts-Dampers
08/14/2017 08/14/2017 BLDG-16 Insulation 031543-2017 Passed Chris Renfro Complete
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
08/17/2017 08/17/2017 BLDG-17 Interior 031927-201 7 Passed Paul Burnette Complete
Lath/Drywall
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Wrong code. Yes
BLDG-24 031928-2017 Cancelled Paul Burnette Reinspection Complete
Rough/Topout
Checklist Item COMMENTS Passed
BLDG-Building Deficiency No
08/18/2017 08/17/2017 BLDG-17 Interior 032091-2017 Passed Paul Burnette Complete
Lath/Drywall
Checklist Item COMMl:NTS Passed
BLDG-Building Deficiency No
BLDG-27 Shower 032090-2017 Passed Paul Burnette Complete
Pan/Tubs
Chocklist Item COMMENTS Passed
BLDG-Building Deficiency No
09/05/2017 09/05/2017 BLDG-23 033645-2017 Passed Paul Burnette Complete
Gas/TesURepairs
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
10/10/2017 10/10/2017 BLDG-Final 037102-2017 Failed Paul Burnette Rei11spection Complete
Inspection
Checklist Item COMMENTS Passed
BLDG-Building Deficiency No
BLDG-Plumbing Final No
BLDG-Mechanical Final No
BLDG-Structural Final No
BLDG-Electrical Final No
November 15, 2017 Page 3 of 4
,< ' I•, " . .
PERMIT INSPECTION HISTORY REPORT (CBR2016-0487)
Permit Type: BLDG-Residential Application Date 12/29/2016 Owner· MA TIHEW WILLMON
Work Class: Addition Issue Date· 02/10/2017 Subdivision:
Status· Closed -Finaled Expiration Date: 03/05/2018 Address: 2726 Inverness Dr
Carlsbad, CA 92010-6520
IVR Number: 1141
Scheduled Actual
Date Start Date Inspection Type Inspection No. Inspection Status Primary Inspector Re inspection Complete
08/03/2017 08/03/2017 BLDG-84 Rough 030581-2017 Failed Paul Burnette Reinspection Complete
Combo( 14,24,34,44)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency No
BLDG-14 No
Frame-Steel-Bolting-Welding
(Decks)
BLDG-24 Rough-Topout No
BLDG-34 Rough Electrical No
BLDG-44 No
Rough-Ducts-Dampers
08/04/2017 08/04/2017 BLDG-22 030808-2017 Passed Paul Burnette Complete
Sewer/Water Service
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
08/07/201 7 08/07/2017 BLDG-17 Interior 030878-2017 Failed Michael Collins Reinspection Complete
Lath/Drywall
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Wrong code. No
BLDG-33 Service 030960-2017 Failed Michael Collins Reinspection Complete
Change/Upgrade
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Notice, release called in on 08/03/2017. No
08/08/2017 08/08/2017 BLDG-17 Interior 031000-201 7 Cancelled Paul Burnette Reinspection Complete
Lath/Drywall
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Wrong code. No
BLDG-24 031001-2017 Cancelled Paul Burnette Reinspection Complete
Rough/Topout
Checklist Item COMMENTS Passed
BLDG-Building Deficiency No
BLDG-33 Service 030999-2017 Cancelled Paul Burnette Reinspection Complete
Change/Upgrade
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Notice, release called in on 08/03/2017. No
08/10/2017 08/10/2017 BLDG-84 Rough 031296-2017 Passed Paul Burnette Complete
Combo(14,24,34,44)
November 15, 2017 Page 2 of 4
. .
'
PERMIT INSPECTION HISTORY REPORT (CBR2016-0487)
Permit Type: BLDG-Residential Application Date: 12/29/2016 Owner: MATIHEWWILLMON
Work Class: Addition Issue Date: 02/10/2017 Subdivision:
Status: Closed -Finaled Expiration Date: 03/05/2018 Address: 2726 Inverness Dr
Carlsbad, CA 92010-6520
IVR Number: 1141
Scheduled Actual Inspection Status Date Start Date Inspection Type Inspection No. Primary Inspector Reinspection Complete
07/28/2017 BLDG-13 Shear 030173-2017 Passed Paul Burnette Complete
Panels/HD (ok to
wrap)
Checklist lturn COMMENTS Passed
BLDG-Building Deficiency No
03/15/2017 03/15/2017 BLDG-SW-Pre-Con 016679-2017 Passed Paul Burnette Complete
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
06/15/2017 06/15/2017 BLDG-24 026265-2017 Passed Jonathan West Complete
Rough/Topout
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
06/26/2017 06/26/2017 BLDG-11 027081-2017 Passed Jonathan West Complete
Foundation/Ftg/Pier
s (Rebar)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-12 Steel/Bond 027082-2017 Passed Jonathan West Complete
Beam
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
07/07/2017 07/07/2017 BLDG-21 028126-2017 Passed Jonathan West Complete
Underground/Underf
loor Plumbing
Checklist Item COMMENTS Pas sod
BLDG-Building Deficiency BBQ gas piping only. Yes
07/28/2017 07/28/2017 BLDG-15 030108-2017 Passed Paul Burnette Complete
Roof/ReRoof (Patio)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
08/02/2017 08/02/2017 BLDG-24 030375-2017 Failed Paul Burnette Reinspection Complete
Rough/To pout
Checklist Item COMMENTS Passed
BLDG-Building Deficiency No
BLDG-31 03037 4-2017 Passed Paul Burnette Complete
Underground/Condu
it-Wiring
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
November 15, 2017 Page 1 of 4
EsGil Corporation
In <Partners nip witn qo~ernment for !Bui(aing Safety
DATE: 2/8/2017
JURISDICTION: City of Carlsbad
PLAN CHECK NO.: R2016-0487
PROJECT ADDRESS: 2726 Inverness Dr.
SET: II
PROJECT NAME: Willmon Residence Remodel & Addition
PLICANT
RIS.
D PLAN REVIEWER
D FILE
~ The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes.
D The plans transmitted herewith will substantially comply with the jurisdiction's
codes when minor deficiencies identified below are resolved and checked by building
department staff.
D The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
D The check list transmitted herewith is for your information. The plans are being held at EsGil
Corporation until corrected plans are submitted for recheck.
D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
D The applicant's copy of the check list has been sent to:
Matthew Willmon
~ EsGil Corporation staff did not advise the applicant that the plan check has been completed.
D EsGil Corporation staff did advise the applicant that the plan check has been completed.
Person contacted: l\lh!,ttl ,e\v \'¥illFAeR Telephone#: 760-683-4276
Date contacted: I}_.. V (b~) Email: m_willmon@hotmail.com
Mail Telephone Fax In Person
D REMARKS:
By: Bert Domingo for DY
EsGil Corporation
D GA D EJ D MB D PC
Enclosures:
2/2/2017
9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (85 8) 560-1468 + Fax (858) 560-1576
I
EsGil Corporation
In <Partnersnip witn qo..,ernment for (!Jui(ain9 Safety
DATE: 1/12/2017
JURISDICTION: City of Carlsbad
PLAN CHECK NO.: R2016-0487
PROJECT ADDRESS: 2726 Inverness Dr.
SET: I
PROJECT NAME: Willmon Residence Remodel & Addition
PPLICANT
URIS.
LAN REVIEWER
D FILE
D The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's codes.
D The plans transmitted herewith will substantially comply with the jurisdiction's
codes when minor deficiencies identified below are resolved and checked by building
department staff.
D The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
~ The check list transmitted herewith is for your information. The plans are being held at EsGil
Corporation until corrected plans are submitted for recheck.
D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
~ The applicant's copy of the check list has been sent to:
Matthew Willmon
D EsGil Corporation staff did not advise the applicant that the plan check has been completed.
~ EsGil Corporation staff did advise the applicant that the plan check has been completed.
Person contacted: Matthew Willmon Telephone#: 760-683-4276
Date contacted:\\ I\ (by:"'l-y Email: m_willmon@hotmail.com
~ail J TelP.ohone Fax In Person
D REMARI\;:;:
By: David Yao Enclosures:
EsGil Corporation
D GA D EJ D MB D PC 1/4/17
9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858) 560-1468 + Fax (858) 560-1576
:
City of Carlsbad R2016-0487
1/12/2017
PLAN REVIEW CORRECTION LIST
SINGLE FAMILY DWELLINGS AND DUPLEXES
PLAN CHECK NO.: R2016-0487 JURISDICTION: City of Carlsbad
PROJECT ADDRESS: 2726 Inverness Dr.
FLOOR AREA:
Living add 525 sf
REMARKS:
DATE PLANS RECEIVED BY
JURISDICTION: 12/29/16
DATE INITIAL PLAN REVIEW
COMPLETED: 1/12/2017
FOREWORD (PLEASE READ):
STORIES: 1
HEIGHT: -13 feet
DATE PLANS RECEIVED BY
ESGIL CORPORATION: 1/4/17
PLAN REVIEWER: David Yao
This plan review is limited to the technical requirements contained in the California version of
the International Residential Code, International Building Code, Uniform Plumbing Code,
Uniform Mechanical Code, National Electrical Code and state laws regulating energy
conservation, noise attenuation and access for the disabled. This plan review is based on
regulations enforced by the Building Department. You may have other corrections based on
laws and ordinance by the Planning Department, Engineering Department, Fire Department or
other departments. Clearance from those departments may be required prior to the issuance of
a building permit.
Present California law mandates that construction comply with the 2013 edition of the California
Code of Regulations (Title 24), which adopts the following model codes: 2012 IRC, 2012 IBC,
2012 UPC, 2012 UMC and 2011 NEC.
The above regulations apply, regardless of the code editions adopted by ordinance.
The following items listed need clarification, modification or change. All items must be satisfied
before the plans will be in conformance with the cited codes and regulations. Per Sec. 105.4 of
the 2012 International Building Code, the approval of the plans does not permit the violation of
any state, county or city law.
To speed up the recheck process, please note on this list (or a copy) where each
correction item has been addressed, i.e., plan sheet number, specification section, etc.
Be sure to enclose the marked up list when you submit the revised plans.
City of Carlsbad R2016-0487
1/12/2017
Please make all corrections, as requested in the correction list. Submit FOUR new
complete sets of plans for commercial/industrial projects (THREE sets of plans for
residential projects). For expeditious processing, corrected sets can be submitted
in one of two ways:
1. Deliver all corrected sets of plans and calculations/reports directly to the City of
Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760)
602-2700. The City will route the plans to EsGil Corporation and the Carlsbad
Planning, Engineering and Fire Departments.
2. Bring TWO corrected set of plans and calculations/reports to EsGil Corporation,
9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468.
Deliver all remaining sets of plans and calculations/reports directly to the City of
Carlsbad Building Department for routing to their Planning, Engineering and Fire
Departments.
NOTE: Plans that are submitted directly to EsGil Corporation only will not be
reviewed by the City Planning, Engineering and Fire Departments until review by
EsGil Corporation is complete.
1. On the cover sheet of the plans, specify any items that will have a deferred
submittal (trusses) Additionally. provide the following note on the plans:
"Submittal documents for deferred submittal items shall be submitted to the
registered design professional in responsible charge, who shall review them and
forward them to the building official with a notation indicating that the deferred
submittal documents have been reviewed and that they have been found to be in
general conformance with the design of the building. The deferred submittal
items shall NOT be installed until their design and submittal documents have
been approved by the building official."
2. Specify on the plans that any existing smoke alarms that are more than 10
years old will be replaced. Section R314.3.2.
3. In dwelling units within which fuel-burning appliances are installed (and in
dwelling units having attached garages), show the locations of permanently wired
carbon monoxide alarms with battery backup, per Section R315:
a) Outside each separate sleeping area in the immediate vicinity of the
bedrooms.
b) On each story, including basements.
• NOTE: When more than one carbon monoxide alarm is required to be
installed, the alarm devices shall be interconnected in such a manner that the
actuation of one alarm will activate all of the alarms in the unit.
4. When alterations, repairs or additions are proposed for dwelling units within
which fuel-burning appliances are installed (and in dwelling units having attached
garages), the dwelling unit shall be provided with carbon monoxide alarms
located as required for new dwellings; the carbon monoxide alarms shall be
interconnected and hard wired. Exception: Carbon monoxide alarms in existing
City of Carlsbad R2016-0487
1/12/2017
areas need not be interconnected and hard wired where the alterations or repairs
do not result in the removal of interior wall or ceiling finishes exposing the
structure, unless there is an attic, crawl space, or basement available which
could provide access for hard wiring and interconnection without the removal of
interior finishes. Section R315.2.
5. Show the required ventilation for attics (or enclosed rafter spaces formed where
ceilings are applied directly to the underside of roof rafters). The minimum vent
area is 1/150 of attic area (or 1/300 of attic area if at least 40% (but not more
than 50%) of the required vent is located no more than 3' below the ridge). Show
on the plans the area required and area provided. Section R806.2.
6. Where eave vents are installed, insulation shall not block the free flow of air. A
minimum of 1" of air space shall be provided between the insulation and the roof
sheathing. To accommodate the thickness of insulation plus the required 1"
clearance, member sizes may have to be increased for rafter-ceiling joists.
Section R806.3.
7. Note on the plans: "Attic ventilation openings shall be covered with
corrosion-resistant metal mesh with 1/16" minimum to Y." maximum openings.
Section R806.1.
8. Show location of attic access with a minimum size of 22"x30", unless the
maximum vertical headroom height in the attic is less than 30". Access must be
provided to each separated attic area (if over 30 sq. ft.), shall be located in a
hallway or other readily accessible location and 30" headroom clearance is
required above the opening. Section R807.1.
9. The garage shall be separated from the residence and its attic area by not less
than Yi" gypsum board applied to the garage side (at walls). Section R302.6.
10. Show a self-closing, self-latching door, either 1-3/8" solid core or a listed 20 -
minute assembly, for openings between garage and dwelling. Section R302.5.1.
11. Provide an 18" raised platform for any FAU in the garage which may generate a
flame or spark. CPC Section 507.13.
12. In the garage, provide an adequate barrier to protect the water heater from
vehicle damage. An 18" platform for the water heater does not satisfy this
requirement. CPC Section 507.13.
13. Foundation anchorage in Seismic Design Categories C, Do, D1 and D2, In
addition to the requirements of Section R403.1.6, the following requirements
shall apply to wood light-frame structures in Seismic Design Categories Do, D1
and D2 and wood light-frame townhouses in Seismic Design Category C.
R403.1.6.1
City of Carlsbad R2016-04S7
1/12/2017
1. Plate washers conforming to Section R602.11.1, 0.229"x3"x3", shall be
provided for all anchor bolts over the full length of required braced wall lines.
Properly sized cut washer shall be permitted for anchor bolts in wall lines not
containing braced wall panels. (Note 15 under shear wall schedule on sheet
S1 .3 shows wrong plate size)
14. Show on the plan the amperage of the electrical service, the location of the
service panel and the location of any sub-panels.
15. Note on the plans that receptacle outlet locations will comply with CEC Article
210.52.
16. Include on the plans the following specifications for electrical devices installed in
dwellings: CEC Article 210 & 406
a) Tamper resistant receptacles for all locations described in 210.52 (i.e., all
receptacles in a dwelling).
b) Weather resistant type for receptacles installed in damp or wet locations
(outside).
c) Arc-fault protection for all outlets (not just receptacles) located in rooms
described in NEC 210.8(A): Family, living, bedrooms, dining, halls, etc.
17. Provide a note on the plans: The control valves in showers, bathtubs, and bidets
must be pressure balanced or thermostatic mixing valves. CPC Sections 408,
409, 410.
18. Specify on the plans whether the existing house was built before or after 1994.
For additions or improvements to a residence built before 1994, note on the
plans that existing "noncompliant" fixtures (toilets that use more than 1.6 gallons
of water per flush, urinals that use more than one gallon of water per flush,
showerheads that have a flow capacity of more than 2.5 gallons of water per
minute, and interior faucets that emit more than 2.2 gallons of water per minute)
shall be replaced. Certification of compliance shall be given to the building
inspector prior to final permit approval. California SB407.
19. Recycling. Note on the plans that a minimum of 50% of construction waste is to
be recycled. CGC 4.408.1.
20. Recycling. Note on the plans that the contractor shall submit a Construction
Waste Management Plan to the jurisdiction agency that regulates waste
management, per CGC 4.408.2.
21. Operation and maintenance manual. Note on the plans that the builder is to
provide an operation manual (containing information for maintaining appliances,
etc.) for the owner at the time of final inspection. CGC 4.410.1.
City of Carlsbad R2016-0487
1/12/2017
22. Pollutant control. Note on the plans that during construction, ends of duct
openings are to be sealed, and mechanical equipment is to be covered. CGC
4.504.1.
23. Interior moisture control. Note on the plans that concrete slabs will be
provided with a capillary break. CGC 4.505.2.1.
24. Interior moisture control. Note on the plans that the moisture content of wood
shall not exceed 19% before it is enclosed in construction. The moisture content
needs to be certified by one of 3 methods specified in Section 4.505.3. Building
materials with visible signs of water damage should not be used in construction.
The moisture content must be determined by the contractor by one of the
methods listed in CGC 4.505.3.
25. Indoor air quality. Note on the plans that bathroom fans shall be Energy Star
rated. vented directly to the outside and controlled by a humidistat. CGC
4.506.1.
26. Note on the plans that prior to final inspection the licensed contractor, architect
or engineer in responsible charge of the overall construction must provide to the
building department official written verification that all applicable provisions
from the Green Building Standards Code have been implemented as part of the
construction. CGC 102.3.
27. All hot water piping sized :Y." or larger is required to be insulated as follows: 1"
pipe size or less: 1" thick insulation; larger pipe sizes require 1 Y:z" thick insulation.
Note: In addition, the Y:," size hot water pipe to the kitchen sink is required to be
insulated. ES 150.00)2
28. Residential energy lighting requirements: ES 150.0(k)
• In the kitchen, at least one-half of the wattage rating of the fixtures must be
high efficacy.
• In bathrooms. at least one fixture shall be high efficacy and all remaining
fixtures shall be high efficacy or be controlled by a vacancy sensor.
• Lighting installed in garages, laundry rooms, and utility rooms shall be high
efficacy and be controlled by vacancy sensors.
• High efficacy fixtures are required for all other rooms (not described above) or
low efficacy fixtures are allowed if controlled by a dimmer or a vacancy
sensor.
• Outdoor lighting fixtures that are attached to a building are required to be high
efficacy or be controlled by a combination photo-control/ motion sensor.
29. Residential ventilation requirements:
City of Carlsbad R2016-0487
1/12/2017
• Kitchens require exhaust fans with a minimum 100 cfm ducted to the exterior.
Detail compliance by including a complying exhaust fan or a ducted range
hood to the exterior.
• Bathrooms require exhaust fans (minimum 50 cfm) to be ducted to the
exterior. A bathroom is defined "as a room with a bathtub, shower, or spa or
some similar source of moisture".
• All fans installed to meet all of the preceding requirements must be specified
at a noise rating of a maximum 1 "Sane" (for the continuous use calculation)
or 3 "Sane" (for the intermittent use calculation).
30. To speed up the review process, note on this list (or a copy) where each
correction item has been addressed, i.e., plan sheet, note or detail number,
calculation page, etc.
31. Please indicate here if any changes have been made to the plans that are not a
result of corrections from this list. If there are other changes, please briefly
describe them and where they are located in the plans.
• Have changes been made to the plans not resulting from this correction list?
Please indicate:
Yes D No D
32. The jurisdiction has contracted with Esgil Corporation located at 9320
Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of
858/560-1468, to perform the plan review for your project. If you have any
questions regarding these plan review items, please contact David Yao at EsGil
Corporation. Thank you.
City of Carlsbad R2016-0487
1/12/2017
[DO NOT PAY -THIS IS NOT AN INVOICE]
VALUATION AND PLAN CHECK FEE
JURISDICTION: City of Carlsbad PLAN CHECK NO.: R2016-0487
PREPARED BY: David Yao
BUILDING ADDRESS: 2726 Inverness Dr.
BUILDING OCCUPANCY: R3
BUILDING AREA Valuation
PORTION ( Sq. Ft.) Multiplier
living 525
Air Conditioning
Fire Sprinklers
TOTAL VALUE
Jurisdiction Code Cb By Ordinance
--------1 Bldg. Permit Fee by Ordinance ....
------
Pla_n Check Fee by Ordi~~-n~e -~ -------····-----------
Type of Review: 0 Complete Review
D Repetitive Fee -~ · -.;:i Repeats
D Other
D Hourly
EsGil Fee
DATE: 1/12/2017
Reg. VALUE ($)
Mod.
per city 107,592
107,592
$654.461
$425.401
D Structural Only
1--------il Hr. @ • $366.501
Comments: In addition to the above fee, an additional fee of $43 is due (1 hour@
$86/hr.) for the CalGreen review.
Sheet 1 of 1
macvalue.doc +
· (cityof
Carlsbad Community & Economic Development
CERTIFICATION OF SCHOOL FEES PAID
This form must be completed by the City, the applicant, and the appropriate school districts and returned to the
City prior to issuing a building permit. The City will not issue any building permit without a completed school fee
form.
Project No. & Name:
Plan Check No.: CBR2016-0487 .=.:..=.:c..:..::...::....c:.c.....~~~~~~~~~~~-
Project Address: 2726 INVERNESS DR
~~~~~~~~~~~~~~~~-
Assessor's Parcel No.: 2081111900 ~~~---~~~~~~~~~~~~~~~~-
Project Applicant: MA TIHEW WILLMON ;.c.;;.~~=..:.'-'-'-'==.:.;..:...---~~~~~~~~~~~-
{ Owner Name)
Residential Square Feet:
New/Additions: 525 -~~~~~~~~~~~~~~~~~~~-
Second Dwelling Unit:
Commercial Square Feet:
New/Additions:
City Certification: City of Carlsbad Building Division Date: 02/09/2017
Certification of Applicant/Owners. The person executing this declaration r0wner") certifies
under penalty of perjury that (1) the infonnation provided above is correct and true to the
best of the Owner's knowledge, and that the Owner will file an amended certification of
payment and pay the additional fee if Owner requests an increase in the number of
dwelling units or square footage after the building permit is issued or if the initial
determination of units or square footage is found to be incorrect, and that (2) the Owner is
the owner/developer of the above described project(s). or that the person executing this
declaration is authorized to sign on behalf of the Owner.
fil~l Carlsbad Unified School District
6225 El Camino Real
Ca~sbad CA 92009
Phone: (760) 331-5000
~ifo'.'J Encinitas Union School District
101 South Rancho Santa Fe Rd
Encinitas, CA 92024
Phone: (760) 944-4300 x1166
f'1;;,;3 San Dieguito Union H.S. District
684 Requeza Dr.
Encinitas. CA 92024
Phone: (760) 753-6491 Ext 5514
(By Appl. Only)
,~\·~;'.·.a San Marcos Unified Sch. District
255 Pico Ave Ste. 100
San Marcos, CA 92069
Phone: (760) 290-2649
Contact: Nancy Dolce
(By Appl.only)
E!fa~;J Vista Unified School District
1234 Arcadia Drive
Vista CA 92083
Phone: (760) 726-2170 x2222
SCHOOL DISTRICT SCHOOL FEE CERTIFICATION
(To be completed by the school dlstrlct(s))
THIS FORM INDICATES THAT THE SCHOOL DISTRICT REQUIREMENTS
FOR THE PROJECT HAVE BEEN OR WILL BE SATISFIED.
The undersigned, being duly authorized by the applicable School District, certifies that the developer, builder, or
owner has satisfied the obligation for school facilities. This is to certify that the applicant listed on page 1 has paid all
amounts or completed other applicable school mitigation determined by the School District. The City may Issue
building permits for this project.
Signature of Authorized School District Official: ~I
-"°-"-"-+"=->l..-"-'--'"--',=c"-=""'-"""-'-'-"'"----------Date: ~ -/ () -) ']
Name of School District: =='-""-":.:r===='-'-'------Phone: f'tloo --3) J -:SW
Building Division
2008 I 760-602-2719 I 760·602-8558 fax I building@carlsbadca.gov