Loading...
HomeMy WebLinkAbout2726 LOKER AVE W; ; 86-641-D; PermitII) z 0 i'.= c( IIC ~ id Q ~ II: e [ D I hereby affirm that I am licensed under U provisions of Chapter 9 (commencing with ~ Section 7000) of Division 3 of the Business ~ , and Professions Code, and my license is in ~ · full force and effect. u IIC ~ ... 3 ~ "' z ~ 1 hereby affirm that I am exempt from the Contrac- tor's License Law tor the following reason (Sec. 7031.5 Business and Professions Code: Any city or county whict"1 re- quires a permit to construct, alter, improve, demolish, or repair any structure, prior to its iss.uance also requires !heap- plicant for such permit to file a signed statement that he is hcensed pursuant to the provisions of the Contractor's License Law {Chapter 9 commencing with Section 7000 of Division 3 al the Business and Professions Code} or that 1s ex- empt therefrom and the basis !or the alleged exemption Any vmlation of S~ction 7031 .. 5 by an applicant for a peri:nit sub-jects the appt1cant to a civil penalty of not more than five hun- dred dollars ($500). I l I, as owner of the property, or my employees with wages as their sole compensation. will do the work, and the struc-ture is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon and who does such work himself or through his own employees, provided that such improvements are not intend-ed or offered for sale. If, however, the building or improve- ment is sold within one year of comple~ion, the owner-builder will have the burden of proving that he did not build or im- prove for the purpose of sale). r:.1 I, as owner of the property, am exclusively contracting B~t~~~:~sae:d ci~~~:~~~~~!0 ii;::trui~~hig~fJ:~:o(?!CLi~~~ie Law does not apply to an owner of property who builds or im- proves thereon, and who contracts for each pro1ects with a contractor(s) license pursuant to the Contractor's License Law). D As a homeowner I am improving my home, and the follow-ing conditions exist: 1. The work is being performed prior to sale. 2. I have lived in my home for twelve months prior to completion of this work. 3. l have not claimed this exemption during the last three years. D I am exempt under Sec. ______ _ for this reason ____________ -+ I I I D I hereby affirm that I have a certific.._a~:._~t/:::nsent to I !~~~~~:~;r· :~=rt~~:~f~c:~; t~te:~~~;~~-w:~~~i~~~;i I z 0 ~ z "' A. :I: 0 u II) ic "' ~ a: 0 3 ll POLICY NO. COMPANY D Copy is tiled with the city D Certified copy is hereby turnishe CERTIFICATE OF EXEMPTION FROM WORKERS" COMPENSATION INSURANCE (This section need not be completed if the permit is for one hundred dollars ($100) or less) D I certify, that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compen- sation Laws of California. NOTICE TO APPLICANT: lf, after making this Certificate of Exemption. you should become subject to the Workers· Compensation provisions of the Labor Code, you must forthwith comply with such provisions or this permit shalt be deemed revoked. D I hereby affirm that there is a construction lending agency for the performance of the work for which this per- mit is issued (Sec. 3097, Civil Code) Lender's Name ____________ _ Lender's Address ____________ _ I I I I I I I I I I I I I I I I I I I USE BALL POINT PEN ONLY & PRESS HARD CARLSBAD BUILDING DEPARTMENT 2075 Las Palmas Dr., Carlsbad, CA 92009-4859 (619) 438-1161 QTY.I PLUMBING PERMIT -ISSUE MECHANICAL PERMIT -ISSUE EACH FIXTURE TRAP INSTALL FURN. DUCTS UP TO 100,000 BTU EACH BUILDING SEWER EACH WATER HEATER AND/DR VENT EACH GAS SYSTEM 1 TD 4 D UTLETS EACH GAS SYSTEM 5 OR MORE t----+---- E AC H INSTA~. ALTER, REPAIR WATER PIPE EACH VACUUM BREAKER WATER SOFTNER EACH ROOF DRAIN I INSIDE) D TOT/",L MECHANICAL TOTAL PLUMBING QTY. I ELECTRICAL PERMIT -ISSUE QTY. I MOBILE HOME SETUP NEW CONST EA AMP/SWT BK CAR PORT 1 PH AWNING EXIST BLDG EA AMP/SWT/ GARAGE 1 PH 3 PH REMODEL'ALHR PER CIRCUIT TEMP PO LE 200 AMPS OVE A 200 AMPS TEMP OCCUPANCY 130 DAYSI TOTAL ELECTRICAL TOTAL APPLICANT TO FILL IN INFORMATION WITHIN SHADED AREA AND DECLARATIONS. VALUATION PERMIT NUMBER -z_.3,j..-0 ZONE fp-0J-1~ oo FIRE SPR y NO Not Valid Unless Machine Certified SUMMARY/ACCOUNT NUMBER BUILDING PERMIT OOH1Q,Q0,00,8220 SIGN PERMIT OOH10-00,Q0,8221 PLAN CHECK 001-810,00-00-8B21 Q) u::: >-;;; 0 C. E Q) f- l "O 0 (!) c <1l 0 C. C. <{ I .:,:: C a: TOTAL PLUMBING OOH10,QO,Q0,8222 I I ELECTRICAL 00~0,~ 10101 o: ·47 J6o.. MECHANICAL 001-810,00,00,8224 0 en MOBILEHOME OOH10,Q0,00-B225 en Q) en SOLAR OOH 10-00,00-8226 en <{ STRONG MOTION 880,519,92-33 I FIRE SPRINKLERS OOH10,Q0,00,8227 ;;: 0 PUBLIC FACILITIES FEE 320,810-00-00-8740 ai BRIDGE FEE 360-810-00,00,8740 PARK,IN,LIEU (AREA >-7 I TIF 134-810-00,00-8835 Q) (.) C LA COSTA TIF 133-810-00-00,8835 <1l C FMF u::: ~ I C Q) ~ (!) 0 t5 Q) C. en Ee I Q) .c ~ TYPE DATE INSPECTOR --I ·. -8"~ -·G,<f't 0 I . BUILDING .. I . FOUNDATION I I 1..-t /_ "'~ t": A A~-_ FIELD INSPECTION RECORD REINFORCED STEEL ! 11/-Y .,, Iv r1/ I REQUIRED SPECIAL INSPECTIONS INSPECTOR'S NO.JES ... ! 4 ' . I I . . ~ ........ , ' . -• _,o;..; .. 1 •. ' MASONRY I '.,· .,c:>'".._~ ,...JW~~t.•·.,... ··'~-• , . .., :t,.,;. .,r, '.,,,. INSPECTiON REQ. IF INSPECTOR'S DATE f: ~~ 7-t. t;l t:~ ~l(tti~t i! i1 V ;) . GUNITE OR GROUT I CHECKED APPROVAL , . SUB FRAME D FLOOR D CEl~..ING . . , •• ""•y SOILS COMPLIANCE . ' D SIHEAR ,, SHEATHING D ROOF PRIOR TO ... FOUNDATION INSP FRAME t 1 STRUCTURAL CONCRETE ~ f .. ·, y, ·=-, • l ll.' f' r) .. EXTERIOR LATH l OVER 2000 PSI ~--.i, ('· \t:~ ~\,-1 ·) ~t i . " INSULATION l PRESTRESSED ., ·. .. CONCRETE ~--. -. . . INTERIOR LATH & DRYWALL ! ~ , PQST TENS)..Ot;:JED ' ' CONCRE:rE· • ··-~ ~ . ,,. \ PLUMB.NG I FIELD WELDING D SEWER AND BL/CQ; D RL/CO HIGH STRENGTH ~ \ " t D W~STE [ BOLTS UNDERGROUND WATER TOP OUT D WASTE' \ D WATER SPECIAL MASONRY . TUB AND SHOWER PAN I , GAS TEST I I PILES CAISSONS D WATER HEATER D SOLARVfATER I .... ~ ._ • ..,.. ri-::-~·.•:",fCJ~~;'.: .. -.. \•-:'..' .. ~'-0 ELECTRICAL ! 0,~x 1• ,~ \.-~i..J v -. ., ..., ..... 7 ~ I D ELECTRIC UNDERGROUND GJ UFFER .. :- • .. ~. , ·, .. ROUGH ELECTRIC I .,_.. . D ELECTRIC SERVICE D TEMpPRARY / D BONDING D POOL I l . ., MECHANICAL D DUCT & PLEM., D REF. PlfllNG ' ;· · .· -·, .. . ' ~ ~~, .. ' ' ··-t. ..• HEAT -AIR COND. SYSTEMS j \ VENTILATING SYSTEMS ; ,. -.. . ........ \ . } · . I • ,• f .· ~-.J .... , ' '····-~ \ '•'' ' . ' CALL FOR FINAL INSPECJIQN WHEN ALI... Afg,ROPR/ATE .. ' - '\, -·· ''""'~ ... .. .. . ·-.. .-,.-, . ' ITEMS ABOVE HA1VE BEEN APPROVE · · ' : ·. \ i~ 1: .. ... I ' . .. -.. /)":if FINAL I ' ... 1;1r' "• : .# .. I -. \. '·,._.·,,· '/. :.~ . ~--.:-~ .. 1 /'· -'/) ,,NI-:-' .. PLUMBING l ~· I . , . ,, ... ELECTRICAL ....l. ,.~ . ;_,J~ '~ ;.~ l')rff .... ,~ ' ... . '.i, . ·-.-{ ~ • ~ ·-(,1 I , ,: ' l 1/11\J J-~ I ..A, A .. ), .,, MECHANICAL "If' __._... 1.,;1 • ; ·\ .. ~ V ~-r61 1 · 1·. --~ -,//1 -v,-:-' ' ' . \ I 'I ' ., j ",..1/-o ~-·, •. \ .. BUILDING J 11. r~,-, r .. . I SPECIAL CONDITIONS i I I I I .4 \ J \J .... SEE 2720 LOK-ER VE W FOR MORE INFO 86-641 INCLUDES 2720,2722,2724 & 2726 LOKER AVE W ... ,.,' FI.NAL BUILDING INSPECTION PLAN CHECK NUMBER: 86-641» DATE: 10-26..,87 . ADDRESS: PROJECT NO.:, ----~--UNIT NUMBER: TYPE OF UNIT: _____ l-_m_s~~------NUMBER OF UNITS: CONTACT TELEPHON.E:_~_c2..::..7..::..6-----'5:..c8o..cl'""0~.·----------------=--· /"""'---- caU. c1~12t L::SAPPROVED INSPECTED . DATE //--c5( Y"'/ APPROVED BY: INSPECTED: . INSPECTED DATE / BY: INSPECTED: APPROVED DI_SAPPROVED ' / INSPECTED DATE BY: INSPECTED: APPROVED DISAPPROVED -~ COMMENTS:------------------------~~--------- Rev. 1/86 WHITE: Suspense BLl)E: Water District GREEN: Engineering CANARY: ·Utilities PINK: Planning GOLD: Fire l ,.•' ... ... 1 . .. '! ,: FINAL BUILDING INSPECTION PLAN CHECK NUMBER: __ !:l_6_-_G_4_1iJ_1 -----------~ 1,-,, .. ·1~ , .. 7 DATE: ,_,.-,_,., ... ..., PRO.:JECT NAME: --~-_C_D-_Zl_.J_b_;._,<l_C_r:_i:i_0_.·i_.:_r;,_.::.~_,r_.,_'P_h_~'_,t._1:?_l ______________ olf_,.,-._,., . 11::!6 1:,i:~r Hld,l"'~~ 0 n" ADDRESS: -~------'----'---=----'--_..:.__----------~-'-------- PROJECT NO.: _______ UNIT NUMBER: _______ PHASE NO.: -----'---- TYPE OF UNIT: _____ 1_J._i(.;_ .. E ______ NUMBER OF UNITS: CT P :-.:nt t: 1tt":J:lt:~/J. "'(.I 1_1--4?'1'" ~,.,.,., CONT A ERSON:·--------'--"--'-"-'"'--'---'--~-'--"'-'-'----------~---~--~ CONTACTTELEPHONE:, ___ i._.7_6_-_S_U_l_O ______ ~-------'----------- INSPECTED 'l'f'I"" L BY: ____ ,_._.,'I'~,.__ ___ _ ~y~P~E-C~T-ED_,,a-J.-1'~'"""------- INSPECTED BY: _____ ~---- DATE INSPECTED: DATE INSPECTED: DATE INSPECTED: • /~~ APPROVED __ DISAPPROVED ~ ~ APPROVED APPROVED ~ DISAPPROVED __ _ DISAPPROVED __ _ COMMENTSt NI.JP~? Bllti/J.< Be !/-LAio' J3 l,l) A/Ge O rz:> JJ g /JLAIJHzl) • l~ .AN.}) Jt2.12.1t:>14Tl~t!L .i"RDSIDU KEPAJIZ. ~.R -------~-----------------------------'• ,, i ~ ,1~, ., ,, ---'--,-~-~-------~------,-----~-~-----------' l \ -----'---------------------------------,+--"' ·,,;;;,;~:.,\..-._:' Rev. 1/86 WHITE: Suspense BLUj:: Water District GREEN: Engineering CANARY: Utilities PINK: Planning GOLD: Fire . FINAL BUILDING INSPECTION PLAN CHECK NUMBS,t. _8_6_-_6_4 ___ l-_D~-----'---------DATE: August 28, 1987 ... _~-,-- PROJECT NAME: __________ _,__ __________________ _ ADDRESS: ___ 2_7_2_6_L_0_K_E_R_A_VE_N_U_E_-_B_LD_G_. _D ____ --'-------------- PROJECT NO.: _______ UNIT NUMBER: _______ PHASE NO.: ______ _ TYPE OF UNIT: __ C_OMM_._' L ________ NUMBER OF UNITS: CONTACT PERSON: ___ W_E_s_· _________________________ _ CONTACT TELEPHONE: __ 9_3_1_-_0_7_63--'---,------,--------"---------------- ALL DEPARTMENTS ::<rCTED ti}~ DATE SEP. o ·s 1987 V DISAPPROVED INSPECTED: APPROVED INSPECTED DATE BY: INSPECTED: APPROVED DISAPPROVED INSPECTED DATE BY: INSPECTED: APPROVED DISAPPROVED COMMENTS: Costa Real Municipal \!'later D1strr-" Engineering Department ~ (619) 438-S~S? · U\ \ r SEP 3 1987 !; I Rev. 1186 WHITE: Suspense BLUE: Water District GREEN: Engineering CANARY: 'Utilities PINK: Planning GOLD: Fire FINAL BUILDING INSPECTION PLAN CHECK NUMB9'~ _8_6_-_6_4_l-_D _______ ___,_~---DATE: August _28, 1987 "",..-- PROJECT NAM~:--:---~-------------~~----~------- ADDRESS: -----'-2_7_2_6_L_O_K_E_R_A_VE_N_1J_E_----,-B_LD_G_. _D _____ --,-___________ _ PROJECT NO.: _______ UNIT NUMBER: --~----PHASE NO.: ______ _ TYPE OF UNIT: __ c_oMM __ ' L ________ NUMBER OF UNITS: CONTACT.PERSON~· --~W_E_S _______ ~--~---------------- CONTACT TELEPHONE: __ 9_3_l_-_0_?_63 ____________ ~----------- ALL DEPART:t1ENTS INSPECTED DATE BY: INSPECTED: APPROVED DISAPPROVED INSPECTED DATE BY: INSPECTED: APPROVED DISAPPROVED -: INSPECTED DATE BY: INSPECTED: APPROVED DISAPPROVED Rev. 1/86 WHITE: Suspense BLUE: Water District GREEN: Engineering CANARY: Utilities PINK: Planning GOLD: Fire I I ----~ . ;t'.~ --~~·c-:~·---_~---, ~. ~:; '· -: SAN-BERN~RDIN0~(714fi~~;iff'.·~=:(_.;3: I Highland Soils Engineering, Inc,,:· '%::: }!, .. · Highland.Ge·otechnical-Consultants, ~7 /;;;;~----:~ · 1 CALABASAS-(818) 888·49'94 . -~~;--;· .. Coast~] Valley Soils Engineering, Inc. -:..;j- Coast~1¥~11eY.}1eotechnical Consultant~_ Irie..-· . . Job: &~QOL-00:- -'--0" "., ~Jj{bi.Ct t.ocatlon: -c;C;._,.1111....-:~,-:f~d-•~a--lC<.~•---'"":::i-u:IS!!!l:1'4--.. «~s-Tract N;o,_. ____ ---'--· ·-. ___ ··,. _.-:, ........----,, . . ~Gfa:d:i:ng: Permit No: ___________________ Lot N.o. _______ _ ; st,;bj'e.ct:__,c_&:.....-IZI. ~zz..u:.cel~4a...=z -"4"4<dc:J.:S~-s~,.,t;.O(',;r:.,;.,_..,a..t:--, _,c.4~6..-,,,e...,):.r-..:,,,.S~L2.-,,::;_-----~--- .-:·:r~~;;:_, ,.t;Jt l lo <IUC,-c~ .-.-... ~--;, ' 6Vd7 1465 MORENA BLVD. • P.O. BOX 80577 • SAN DIEGO, CALIFORNIA 92138 • (619) 276-5810 CONTRACTORS LICENSE NO. 418833 TO: CITY OF CARLSBAD-1200 Elm Avenue Carlsbad, 92008 ADDA ESS: _ .... Ja....,y.__E....;..l_l_io_t_t..._/,_H_CH_&_A_S_SO_C_. __ _ Neil Medlock/FIVE M DEVELOPMENT Wes Philo/NINTEMAN CONSTRUCTION ATTENTION: ____________ _ WE ARE SENDING YOU: D Shop drawings D Copy of letter· D Attached COPIES DATE 0 Material list 0 Test Reports D Under Separate Cover NO. REFERENCE Nb. ___ s __ o ___ o-'-4-"'-l _______ _ DATE: 5/19/87 PROJECT: Carlsbad Crossroads-Phase I JOB N0: ___ 2_20_1 _________ _ D Catalogs 0 Color Samples D Brochures 0 Samples D ----------------- DESCRIPTION . 1 ea 5/6/87 2 Footing Observations Report from San Diego Soils Engineering THESE ARE TRANSMITTED as checked below: D For approval xxJiet For information D For review and comment D Approved a~ submi~ted 0 Approved as noted D Revise and resubmit 0 Resubmit __ copies for approval 0 Return __ corrected prints 0 FOR YOUR ACTION REMA 0 RKS: ------------------------,,----------------- Copy D istr ibutio n Enclosure WHITE ADDRESSEE CANARY Wes ves /4·Q~.e ~ 9 PINK File yes GOLD CHRON. NO BY: . s:. < ., 1/ Dee L. Irwin, Project Admintrator May 6, 1987 SAN DIEGO SOILS ENGINEERING, INC. SOIL ENGINEERING & ENGINEERING GEOLOGY .Ninteman Construction Company 1465 Morena Boulevard Job No. 05-6983-001-00-10 Log No. 7-1544 San Dieg.o, California 92110 Attention: 'Mr. Mat Reno SUBJECT: FOOTING OBSERVATIONS Carlsbad Crossroads. Phaae I Buildings A, B, C, D Carlsbad, California References: (1) San Diego Geote·chnical Consultants, Inc., April 15, 1987, Soils Compaction Report, Precise Grading Completed -Building Pads Only Carlsbad Cros.sroads, Phase I, Buildings A, Gentlemen: B, C, and D, Carlsbad, California Job No. 05-6983-001-00-10 (2) San Diego Geotechnical Consultants, Inc., November 20, 1986, "Foundation Investigation, Carlsbad Oaks Business Center, Job No. 30065-00 (3) San Diego Geotechnical Consultants, Inc., February 19, 1987, "As-Graded Geotechnical Report, Final Report of Mass Grading, Carlsbad Oaks Business Center, Carlsbad Tract 74-21, Carlsbad, California" Job No. 05-1079-002-00-10 This is to confirm. that w~ have observed the foundation excavations for Phase 1, Buildings A, B, C, ~ D at the project site. It is our opinion that the excavations have b~en prepared in conformance with our previ_ous recommenda~ions and that the foundation soil conditions are as anticipated in the referenced reports. SUBSIDIARY OF IRVINE CONSUL TING GROUP, INC. 6455 NANCY RIDGE DRIVE• SUITE 200 • SAN DIEGO, CA 92121 • (619) 587-0250 Ninteman Construction Company ... -· " May 6, 1987 Job No. 05-6983-001-00-10 Log No. 7-1544 Page 2 This opportunity to be of s.ervice is sincerely appreciated. If you should have any further questions, please do not hesitate to contact the undersigned at your convenience. Very truly yours, SAN DIEGO SOILS ENGINEERING, INC. Erik J. Nelson Staff Engineer AFB/pb Distribution: · (6) Addressee. /772_ 7 /JJ-/~ A~~;~Jelfa~;, /;. C 40333 Registration Expires: 3-31-91 Chief Engineer ,; GOLD.SEAL Standard of Excellence • Continuous mixing of liquid to liquid adhesive. Adhesives eomply with ASTM D 2559-82. • .\'tember cross-section average moisture content 12% maximum. • Proof loaded Tension Zones. • Certified Tension graded lumber to AITC 302 specification. • Lumber 100% inspected by a · grader certified by an ICBO- approved independent agency. 'T' imber Products Inspection, Inc. hereby certifies that the products identi-1 fled below and on attached sheets Nos. J -6 are marked with the Official Mark of Timber Products Inspection, Inc. (TP) and were manufactured in conformance with applicable provisions of American National Standard ANSI Al90.l-1983, Structural Glued Laminated Timber, Uniform Building Code 1985, Section 2511, and as modified by _______ _, and that such manufacture has been by STANDARD STRUCTURES, INC-. in WINDSOR, CA , which plant has a quality control system approved by the Inspection Bureau of Timber Products Inspection, Inc. and inspected by a full-time, resident inspector of the Bureau, periodically audited by a Bureau Supervisor and Bureau management The manufacture of these members complies with the manufacturing and fabricating provisions of Chapter 25 of the Uniform Building Code. Further, these described products were manufactured in-conformance with the Gold Seal.Standard of Excellence as summarized on this certificate. JOB NAME: CARLSBAD CROSSROAD JOB LOCATION: LOOKER AVE WEST CUSTOMER ORDER NO.: __ _ DATE:1-23 MFGR. ORDER NO.: __ _ ORDER SPECIFICATIONS: Fb 2400 I Appearance 55 GLULAMS/INDUSTRIAL Adhesive EXTERIOR Signature / J?-Mj w~ Titlf' OC INSPECTOR Date 8-25-87 Timber Products Inspection, Inc. Portland. Oregon Timber Products Inspection, Inc ... an APPROVED COMPLIANCE AGENCY NER #275 (superseding ICBO AA507, originally dated 1946), hereby certifies that said company at its said plant is licensed by Timber Products Inspection, Inc. to use the TP Mark in respect of products which comply with applicable provisions of said Standard, that the adequacy of the quality control system in effect at said plant is daily inspected and verified by the Inspection Bureau of TP and that in the judgement of TP, said company is capable of complying with applicable manufacturing and testing provisions of said Code, Standard, and Report in respect of products manufactured at said plant TP guarantees that said manufacturer is qualified to produce a product meeting ANSI Al90.l-1983 and th· ·s plant is daily inspected and verified by TP Inspection Bureau. TP GOLD SEAL CERTIFICATE NO. Timber Products Inspection, Inc. • P.O. Box 20455 • Portland. Oregon 97220 P AG:: 5 0 f= 6 !~1 AN U :=AC T ~ ~ I ~~ G O~DS~ ' 27-~UG-87 " , M•<T/CARLSSAD CR S-H-so:,26-RG-1 87-JAN-23 Su co PG20 3-1 CARLSSAb CROSSROA2 BJS LOOK::R AVE WEST 619-562-1125 CARLSSAD CA M R TIMBER 87-MAR-20 8625 ARGENT STREET SANTEE CA 92071 FOB ON TRK/JOBSITE DRAWINGS BY CUSTOr,!ER IND 2 NOM LAM COMB 24F CHAPMAN BU·ND WR ti.P DOUG FIR IO MARK QTY WIDTH DEPTH LENGTH CANT L CAMBER RADIUS CANT R BOARD TAG ELEV L ., , ELEV R FEET NU~BERS C 6C3 1 5-1/8 27 69 6 11 0-3/4* 4901 9 1267 44 Ve C BC4 2 5-1/8 25-1/2 35 4 ... 114 1-1/2 1200* 1220 45-46 V4 C 6C5 2 S-1/8 25-1/2 36 0-1/4 1-5/8 1200* 1 243 47-48 V4 C SC6 1 5-1/8 22-1/2 36 0-1/4 1-5/8 1200* 549 49 V4 i) 6D1 1 5-1/8 30 66 6 8 1 * 3825 1347 50 V8 D BDZ 1 5-1/6 34-1/2 63 2-1/4 1-1/4 3000* 14 1472 51 D BJ4 1 5-1/8 30 41 2-1/4 2-1/8 1200* 8~6 52 V4 D 803 1 5-1 /8 16-1 /2 21 0-1/4 0-718 800* 236 53 V4 D 8D5 1 5-1/8 30 41 6-1/4 1-'1 /4 2000* 843 54 V4 SO CO PG20 6-1 CARLS3~D CROSSROA9 LOOKER AVE WEST CARLSBAD C.A M R THISER 8625 AR&ENT STREET SANTEE CA 92071 DRAWINGS. BY CUSTOMER 27-AUG-8 7 PAGE MRT/CARLS8AD CR S-H-50926-RG-1 87-JAN-23 30':, 619-562-1125 87-MAR-20 6 OF F03 CN TRK/J03SITE IND 2 NOM LAM co·Ms 24F CHAPMAN BUND WRAP DOUG FIR ID MARK QTY WIDTH D~PTH LENGTH D B D 6 1 5 -1 / 8 3 4-1 / 2 4 9 2.-1 / 2 CANT L ELEV L V4 CAMBER RADIUS CANT R BOARD " ' ELEV R FEET 2-1/4 1600* 1147 6 TAG NUMBERS 55 REGISTERED INSPECTOR'S WEEKLY REPORT COVERING WORK PERFORMED REINFORCED-CONCRETE WHICH REQUIRED APPROVAL O PRE-STRESSED CONCRETE BY THE SPECIAL INSPECTOR-OF O REINFORCED MASONRY CONSTRUCTION LABORATORIES 6455 NANCY RIDGE DRIVE, SUITE 200 SAN DIEGO, CA 92121 (619) 587-0250 0 STRUCT. STEEL ASSEMBLY 0 REINFORCED GYPSUM 0 GLUE"LAM. FABRICATION 0 OTHER [J PILE DRIVING FOR WEEK ENDING JOB NO. INSP'N. DATE LOCATIONS OF WORK INSPECTED, TEST SAMPLES TAKEN, WORK REJECTED, JOB PROBLEMS, PROGRESS, REMARKS, ETC. Includes information about· amounts of material placed or work performed; number, type, and identify numbers of test samples taken; structural connections (welds made, h.t bolts.torqued) checked; etc. CERTIFICATION OF COMPLIANCE I HEREBY CERTIFY THAT I HAVE INSPECTED ALL OF THE ABOVE REPORTED WORK, UNLESS OTHERWISE NOTED· I HAVE FOUND THIS WORK TO COMPLY WITH THE APPROVED PLANS SPECIFICA· TIONS, & APPLICABLE SECTIONS OF THE AGENCY REQUIREMENTS. 08-Jul-88 I V TOTAL 262,897.20