2726 LOKER AVE W; ; CB060791; Permit
~: City of Carlsbad 05-1'2-2006 1635 Faraday Av Carlsbad, CA 92008 Commercialnndustrial Permit Permit No: CB060791 . Building Inspection Request Line (760) 602-2725 Job Address: Permit Type: Parcel No: Valuation: Occupancy Group: Project Title: 2726 LOKER AV WEST CBAD ti Sub Type: 2090812800 Lot#: $35,000.00 Construction Type: Reference #: POWERMETAL TECHNOLOGIES 1,000 SF OFFICE TO OFFICE COMM 0 NEW Status: Applied: Entered By: Plan Approved: Issued: Inspect Area: Plan Check#: Applicant: Owner: DESIGN/BUILD TENANT IMP. SUITE B 9770 CARROLL CENTER RD. SAN DIEGO, CA 92126 619-954-9519 Building Permit Add'I Building Permit Fee Plan Check , Add'I Plan Check Fee Plan Check Discount Strong Motion Fee Park Fee LFM Fee Bridge Fee BTD #2 Fee BTD #3 Fee Renewal Fee Add'I Renewal Fee Other Building Fee Pot. Water Con. Fee Meter Size Add'I Pot. Water Con. Fee Reel. Water Con. Fee $270.79 $0.Q0 $176.01 $0.00 $0.00 $7.35 $0.'00 $0.00 $0·.oo $0.00 $0.00 $0.00 $0:00 $0.00 $0.00 $0.00 $0.00 FENTON H G COMPANY · 7577 MI$SION VALLEY RD SAN DIEGO CA 92108 Meter Size Add'I Reel. Water Con. Fee Meter Fe~ SDCWAFee CFD Payoff Fee PF"F (3105540) PFF (4365540) License Tax (3104193) License Tax (4304193) Traffic Impact Fee (3105541) Traffic Impact Fee (4305541) Pl,.UMBING TOTAL ELECTRICAL TOTAL MECHANICAL TOTAL Master Drainage Fee -Sewer Fee Redev Parking Fee Additional Fees i-lMP Fee TOTAL PERMIT FEES Total Fees: $535.65 Total Payments To Date: $535.65 Balance Due: . FINAL APPROVAL PENDING 03/20/2006 KG $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $27.00 $20.00 $34.50 $0.00 $0.00 $0.00 $0.00 ?? $535.65 $0.00 Inspector:~ Date: _.....,...,_-~--Clearance: _____ _ NOTICE: Please take NOTICE that approval of your project includes 'the 'Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as 'fees/exactions.' You have 90 days from the date this pennit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul·their imposition. . 0607901-1 0037 03/20/2006 001 15 FOR OFFICE USE O~ '! PERMIT APPLICATION PLAN CHECK NoCJ?Ofao1q I f' CITY OF CARLSBAD BUILDING DEPARTMENT 1635 Faraday Ave., Carlsbad, CA 92008 Address (include Bldg/Suite #) Business· Name (at this address) '2.1'2<.o t..O't.e\2. hJ6. wesr '90'N'0Z..H~. '"{e':l..,~C~\'f,';:,, INC.... Legal ·Descriptie>n Lot No. Subdivision Name/Number Unit No. Phase No. 1 Total # of units :ffi~l?t ~1'-l-2\ MW""' lce12.. YN¥b 0r 6-(o Assessor's Parcel # J ~ Existing Use Propo.sed Use "Z.<::P\ • 0 't> \ • <2. <c, • Ob -'B--Qffi {h '&-QfflU;., #of Stories # cit Bedrooms # of Bathrooms \ ~/A f~ ': ', ''. ~. ~-:N,:~'''t: , --'-, ~ ..... -< State/Zip Telephone# Name Address City State/Zip Telephone # '4-2:.iRO,iERl?O:lWNtR ·~ .. ' ·. H·: ·, :, \:\. (;:J. ~ c..c. Name Address City S.tate/Zip Telephone# L~._,_\~tQ!III!!A~'.@lJlfi~r.i'X'.;NAM.li· : · ... · '.. . . ; .. ~-. ·• · ~-.... :~ · .. : , _-;,-.. · --~··-..:·~-,-.. -.· ·--·--·---· Fax# (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its ·issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law [Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code]' or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031..5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars [$500]). "O!;ro q::U o ~QLLcrJ?.-.@?. t C.1 ~ 'DI~ C,A/°1,1,,\t-l.P £r>cp, ·5~ ·f>c{';,~ Name Address City State/Zip Telephone# State License# L\ (t)(o~ License Class 'e, City Business License# ''i.l~C"l(D Designer Name Address City State/Zip ·Telephone State License # -------~-- ~-~_.::Jr{O}i@MF:gQ~~Fl\!~AIIQJ'~:::,:"'· ...... ." ........ , · . _.:· .. .'. :,, :: ~,· ... .-.. :.~.:} >.:::::· ... :.~·,..;,.~'.:., Workers• Compensation Declaration: I hereby affirm under penalty of perjury one of the following declarations: 0 I-have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. ~ I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My worker's compensation insurance carrier and policy number are: Insurance Company b{...J...oV,-,'Q Policy No. -'o-i~:)7~'-t,(o Expiration Date O\ • 0\ • CG (THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS ($100) OR LES_S) 0 CERTIFICATE·OF EXEMPTiON: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Campen aws of California. WARNING: Failure t~~~~=:R:1;~ ... ".";, :ii'tb/:.§3~-~-; f;_E~c~f:A~R~A~~T~I-O~Nf:_:::_.,==.:~·--===.-~ .. -:-. -:-:.-. 1-._ .~ ... -~·:.~.!,,,: .. ~-__-":", .7_: :-:. :7· :::-:-:\·'.:-:-. -:_.:"."'.: .-:-:_. _-:-: -:: .-,.-:_:-::--. _-, .. '. ;=-;--:::. ~::::;- I hereby affirm that I am exempt from the Contractor's License Law for the following reason: 0 I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec, 7044, Business and Professions Code: The Contractor's License !,aw does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended-or offered for sale. If, however, the building or improvement is sold within-one year of completion, the owner-builder will have the burden of proving that he did not build or improve for. the purpose of sale). 0 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). D I am exempt under Section ______ Business and Professions Code for this reason: 1. I-personally plan to provide the-major labor and materials for construction of the proposed property improvement. D YES ONO 2. I (have / have not) signed an application for a building permit for the proposed work. 3. I have contracted .. with the following person (firm) to provide the proposed construction (include name/ address/ phone number/ contractors license number): 4. I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone number/ contractors.license number):. _____________________ ~-~---------------------- 5. I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name./ address / phone number / type of work):. ______________ ~----------~--~~-----~~-------------------- PROPERTY OWNER SIGNATURE _______ ~~---~~-----~--DATE ________ _ ~l'll.l!~ .. ett?~~1s·-$-EQ.RQNJSQB.:~,;;1~~Rg~,Q~n~L _ayuJ~~J~<~teeJ\M~r~:oJY.t.Y ,5.~·~~-\.,:¥\ :~----. --~-':. =--~w:-~_.-~:~,,~ :.:,_-__ -~:·:~1;::-f:_x~~~ ;-~ :~·~-,-:;:. --~t:--~-·, Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? D YES D NO Is tt\e applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? 0 YES D NO Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? D YES O NO IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE·OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. ffi2~~QNs,rm,CTION'UNDlNG;AGEfrCY <. , ,:. ·. ·.· ·. '. '.:.;_ ,,_ ,. · , _ .. · , "··,;; ... •:':::'""''.'.'.:: ,+71,_.;; .::f~,: I hereby affirm that there is a construction lending agency for the 1i'erfcirmance of the work for which this permit is.issued (Sec. 3097(i) Civil Code). LENDER'S NAME :;;;;;;;;;:;;;;:;;:;;:;;;;;;:;;=:;::;::==:=:::::::::-:::=:::;:;::=:: LENDER'S ADDRESS ~,:::.:..;::A~~N:E'9!'.13:1:!flQAJJQNI.., .. ~~.-,,, .. ;:,: •.•. [.' .... ,~; .. ; .. ; ~-: ......... ,'·· .... c ~.,:;:=::;::;:;;;::;:;:;:;;~=:;;;;~:;:_:;:;;;;:;:;=::;=;;::::;:;:;:;;:;:::::;::;:::;::;:;:;,::;::;::;:::::.:::::;:;:;::::;;:;:;;=. I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all City ordinances and State laws relating to building construction. I hereby authorize representatives of the Citt of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY INANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: An OSHA permit is required for excavations over 5'0" deep and·demolition or construction of structures over 3 stories in height. EXPIRATION: Every permit issued b t e building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is not c m ced wI da"lrdlllli!'141li.edate of such permit or if the building or work authorized by such permit is suspended or abandoned at any time after the work is c n d for a peri (Sec ·on 106.4.4 Uniform Building Code). APPLICANT'S SIGNATUREA"""2t.~~~~e:~~~:::j~.___________ DATE . o 3 · -z-o ·i.oo:W YELLOW: Applicant PINK: Finance ', ', ~· -. List 1 -Permit-Type From the following list, determine the permit-type that best describes the work you propose to do. Please put the code'of that' •. permit-type in the blank at the top of the page on the front of this application. Residential permits (only) also require the identification of the structure-type to be associated with the permit. Choose a structure-type from "List 2 -Structure-Types" and put its code in the appropriate blank on the front of this application. Residential Permits Code Description APT Aoartments -new construction. CONDO Condominiums -new· construction. · . , . CVNNR Conversion. Convert all or a portion of a residential units. non-residential building. to r~sidential use, creating-one or more new CVNRN Conversion. Convert one or more residences in a building to non-residential usage. CVNRR Conversion. Increase or reduce the number of dwelling units in a r~idential structure through interior modifications (i.e.: a four bedroom house converted to a duplex, with 2 bedrooms each). DEMO Demolition oermit. (Also specifv type of structure from List 2). DUP Duplex -new ce>nstruction. MOHO Mobile li.ome,'renovation, repair,' or addition of acc~sory structure not yielding a new living unit. . . . , . . MOHON Mobile home, pre-fabricated house, or trailer installed (plumbed, wired) in a mobile home park (see distinction from single-family.residence, below}. · .. _ · _ . ,. . . · . . . . , RAD Residential addition/alteration, creating no new dwelling unit(s). RREISSUE Residential permit re-issue. RREPAIR Residential building repair. Damage, fire, etc. RREPLACE Residential building r~placem~nt (no additional units). SFA Single-family, attached -new construction. A one-family hous'e attached to one' or more other houses, with one or more common w,alls extending from foundation to roof at, or forming, a lot line. Has own plumbing and heating svstem (e.g.: townhouse, row house, half-plex) SFD Single-family, detached -new construction: A one-family house with open area on all four sides. May have an attached or detached garage, or a business. May be a detached "granny fl.at". May be a mobile home or trailer on an individual lot, but not in a mobile home park. Non-Residential/ Accessory Permits Code Description COM Commercial structure, new construction. CREISSUE Commercial permit re-issue. ' CREPAIR Commercial building -repair. Damage, fire, etc. CREPLACE Commercial building -replacement. CTI Commercial tenant improvement. DEMO Demolition permit. ELEC Electrical permit, for electrical work only. HOTEL Hotel or motel (including Managed Living Unit hotel) -new constructiqn. HOTELR Hotel renovation. INDUST Industrial structure, new construction. 111 Industrial tenant improvement. MECH Mechanical permit, for mechanical work only. MISC Miscellaneous. Use only if proposed work doesn't fit another activity type. PATIO Patio and/or deck. PLUM Plumbing permit, for plumbip~ work only. POOL Gunite pools and spas. RETAIN Retainin~ wall oermit. SIGN Sign construction/installation permit. SOLAR Solar energy system installation permit (specify structure type to be served). SPA Factory-made or Gunite. -----~------· -~ -----·-· _. --------·-~ -----·---~ -----------------·----~----.---·----- List 2 -Structure-Type (Use with Residential Permit Only) From the following list, determine the type of residential structure that best describes the structure on which you will be working. Please put the code of that structure-type in the appropriate blank at the top of the page on the front of this application. Code Description SFA Single-family, attached. A one-family house attached to one or more other houses, with one or more common walls extending from foundation to roof at, or forming, a lot line. Has own plumbing and heating system (e.g.: townhouse, row house, half-plex). SFD Single,family detached: A one-family house with open area on all four sides. May have an attached or detached garage, or a business. May be a detached "granny flat". May be a mobile home or trailer on an individual lot, but not in a mobile home park. MF2-4 Multi-family, 2 to 4 units. A residential structure on a single lot, containing two, three, or four dwelling units. Units may share master heating, plumbing, or electrical service (e.g.: duplex, triplex, quad-plex). MFS+ Multi-family, 5 or more units. Same as MF2-4, except the building has a t least five attached units on the sa11J.e lot. MOHO Mol:)ile hc;:,me, P,re-fabricated house, or trailer installed (plumbed, wired) in a mobile home park (see distinction from single-family residence, above). '' City of Carlsbad Bldg Inspection Request For: 03/12/2007 Permit# CB060791 Title: POWERMETAL TECHNOLOGIES Description: ·1,000 SF OFFICE TO OFFICE Type:TI Job Address: Sub Type: COMM Suite: Location: OWNER Owner: Remarks: Total Time: , 27~6 LOKER AV WEST Lot 0 FENTON H G COMPANY CD Desc~iption Act Comment 19 Final Structural gl 29 Final Plumbing 39 Final Electrical 49 Final Mechanical Comments/Notices/Holds Associated PCRs/CVs Original PC# PCR06154 ISSUED POWER METAL TECH-MECH REVISION; Inspection History Date Description Act lnsp Comments Inspector Assign·ment: TP --- Phone: 6199544704 · Inspector: L Requested By: . GEORGE Entered By: CHRISTINE 01/30/2007 89 final Combo co TP SAME CORR HOOD EXHST. DTL. 11/07/2006 89 Final Combo . 11/06/2006 89 Final Combo 08/01/2006 89 Final Combo 05/19/2006 14 Frame/Steel/Bolting/Welding 05/19/2006 17 Interior Lath/Drywall co NR co AP AP TP NEED FIRE APR. & HOOD ·EXHST DTL TP TP NOTICE ATTCH TP TP DATE: 5/lQ/06 JURISDICTION: Carlsbad PLAN CHECK NO.: 060791 · EsGU Corporation In Partnersliip 'Uiitn. (jo,11ernment for i:Buifi{ing Safety SET:llt PROJECT ADDRESS: 2726 Loker Ave. West PROJECT NAME: Powermetal Tech~ologies, R &: D Enclosure ~ANT ~ D PLAN REVIEWER D FILE · •. The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. D The plans transmitted herewith will substantially comply With the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. O· The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. D The check list transmitted herewith is for your information. The plans are bein~rheld at Esgil Corporation UAtil corrected plans are submitted for recheck. 0 The applicant's copy of the check list is enc1osed for the jurisdiction to forward to the applicant cont8:ct person. D The applicant's copy-of the check list ·has been sent to: • Esgil Corporation staff did not advise the applicant that the plan check has been completed. D Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Date contacted: (by: ) Mail Telephone Fax In Person D REMARKS: By: Chuck Mend~11hall Esgil Corporation D GA D MB D EJ . D PC Telephone #: Fax#: Enclosures: ,fAX In-trnsmtl.dot 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858) 560-1468 + Fax (858) 560-1576 -·,.J •' i ~-. DATE: 4/26/06 JURISDICTION: Carlsbad PLAN CHECK NO,: 060791 EsGil Corporation In Partnersliip witli (jovemment for'i3ui(aing Safety SET:11 PROJECT ADDRESS: 2726 Loker Ave. West PROJECT NAME: Powermetal Technologies, R & D Enclosure D~NT q:::!9R@:EVIEWER D FILE D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. D The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. D, The plans transmitted herewith have significant .deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck . • The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclbsed for the jurisdiction to forward to the applicant contact person. II The applicant's copy of the check list has been sent to: Design/ Build, Att'n: Toni Pinon 9779 .Carroll Center Rd., suite 'C', San Diego, CA 92126 D Esgil Corporation staff did not advise the applicarat that the plan check has been completed. • Esgil Corporation staff did advise the applicant that the plan check has been completed. D Person contacted~[ Tot Pinon Date contacted: crarz(tfe (by:-fa.>c) Mail Telephone Fax--/41Person REMARKS: By: Chuck Mendenhall Esgil Corporation D GA D MB D EJ D PC Telephone#: (858) 549-8455 Fax #: (858) 530-1779 Enclosures: 4/19/06 trnsmtLdbt 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858) 560-1468 + Fax (858) 560-1576 Carlsbad 060791 41::,26/06. '(-. Please make all corrections on the original tracings, as requested in the correction list. Submit three sets of plans for commercial/industrial projects (two sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA . 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by E:sGil Corporation is complete. NOTE: The items listed below are from the previous correction list. These remaining items have not been adequately addressed. The numbers of the items are from the previous check list and may not necessarily be in sequence. The notes in·bold are current. 1. What is the purpose of the extraction exhaust equipment located within the warehouse? See M- 1 of the plans. The response was to evacuate dilute amount of permanganate. However, there .are no exhaust hoods provided. The information indicates " Ducting for fume hood in material slab. Fume hood and fan to be provided by tenant" What does this mean? Is the warehouse not for storage but for manufacturing of products using toxic materials. The brief description of the business is the prototyping and testing using nanometal as deposited using electro deposition. The hazardous materials lists many different types of acids and volatile cleaning. solutions. Provide a listing based on UBC Table 3D & 3E. It appears that the warehouse is other than strictly storage. The use appears to be manufacturing using hazardous materials. · 2. Whi:tt type of fumes does the extraction exhaust to the exterior? Is the exhaust for flammable, cornbustiple or caustic chemicals? Please clarify. Without this information there is no way for me to verify the occupancy classification or whether there are special .code requirements for the extraction exhaust ducts and location of the exhaust on the toot. Provide manufacturers information for the fume extraction ducting and hoods. These must be listed and approved for use with caustic, .corrosive and volatile materials. 5. Provide a note on the plans indicating whether any hazardous materials will be stored and/or used within the building which exceed the quantities listed in UBC Tables 3-D and 3-E. Noting listed on the plans or provided in the hazardous materials sheets that relate to the UBC Table 3D & 3E 6. Provide a complete description of the activities and processes that will occur in this tenant space ( R & D robm and warehouse with extraction exhaust) should be provided. A listing of all hazardous materials should be included. The materials listing should be stated in a form that would make classification in Tables 3-D and 3-E possible. The building official may require a technical report to identify and develop methods of protection from hazardous materials. Section 307.1.6. The description of the building use appears to fit the description of an H3 occupancy. The H3 occupancy must have exhaust fume hoods that comply with UBC Carlsbad 060791 4626/06~ . .., Section 1202.2.3. Spill control is required for the containment of hazardous materials as required by the Fire Code. Spill control per UBC 307.2.4 must be approved by the Fire Department . END OF REVIEW To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Chuck Mendenhall at Esgil Corporation. Thank you. -1 E·sGil Co.rporation ,. ~ In Partnersfiip witfi (jovernment for 'BuiCaing Safety DATE: 3/29/06 D APPLICANT D JURIS. JURISDICTION: Carlsbad D PLAN REVIEWER D FILE PLAN CHECK NO.: 060791 SET: I PROJECT ADDRESS: 2726 Loker Ave-. West PROJECT NAME: Powermetal Technologies, R & D Enclosure D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. D The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor defici.encies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for_ a complete recheck. • The check list transmitted herewith ·is for your information. The plans are being held at Esgil Corporation until corrected plans are. submitted for .recheck. D The applicant's copy of the check list is enclosed fot the jurisdiction to forward to the applicant contact person. • The applicant's copy of the check list has been sent to: Design/ Build, Att'n: Toni Pinon 9779Carroll Center Rd., suite 'C', San Diego, CA 92126 D Esgil Corporation staff did not advise the applicant that the plan check has been completed. • Esgil Corporation staff did advise the applicant th.at the plan check has been completed. Person contacted: Toni Pinon Telephone#: (858) 549-8455 Date contacted:0/.7..?f /do(by:~ Fax. #: (858) 530-1779 Mail Telephone hax /4 Person D REMARKS: \JN\ By: Chuck Mendenhall Esgil Corporation D GA D MB D EJ D PC Enclosures: 3/23/06 trnsmtl.dot 9320 Chesapeake Drive, Suite 208 + San Diego, Califorp.ia 92123 + (858) 560-1468 + Fax (858) 560-1576 Carlsbad 060791 3/.29/06 PLAN REVIEW CORRECTION LIST TENANT IMPROVEMENTS PLAN CHECK NO.: 060791 . OCCUPANCY: B, Fl, SI TYPE OF CONSTRUCTION: V N ALLOWABLE FLOOR AREA: no change SPRINKLERS?: Yes REMARKS: DATE PLANS RECEIVED BY JURISDICTION: DATE INITIAL PLAN REVIEW COMPLETED: 3/29/06 FOREWORD (PLEASE READ): JURISDICTION: Carlsbad USE: R & D lab, offices and warehouse ACTUAL AREA: I 000 TI Only STORIES: no change HEIGHT: _no change OCCUPANT LOAD: 5 TI Only DATE PLANS RECEIVED BY - · E$GIL CORPORATION: 3/23/06 PLAN REVIEWER: Chuck Mendenhall This plan review is limited to the technical requirements contained in the Uniform Building Code, _ Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled: This plan review is based on regulations enforced .by the Building Department, You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Code sections cited are based on the 1997 UBC._ The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3, 1997 Uniform Building Code, the approval of the plans do£?s not permit the violation of any state, county or city law. To speed up the recheck process, please note· on this list (or a copy) where each correction item has been addressed, i.e., plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans. TENANT IMPROVEMENTS WITHOUT SPECIFIC ENERGY DATA OR POLICY SUPPLEMENTS (1997UBC) tiforw.dot '•' Carlsbad 060791 3:/29/06 1:. Please mc;1ke all corrections on the original· tracings, as requested in the correction list. Submit three sets of plans for commercial/industrial projects (two sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1'635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City wiU route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring one corrected set of plans and calculations/reports to EsGil Corporation, · 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560~ 1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by _EsGil Corporation is complete. What is the purpose· of the extraction exhaust equipment'located within the warehouse? See M-1 of the plans. . 2. ·what type of fumes does the extraction exhaust to the exterior? Is the exhaust for flammable, combustible or caustic chemicals?· Please clarify. Without this information there is no way for me to verify the occupancy classification or whether there are special code requirements for the extraction exhaust ducts and.'location of the exhaust on the roof. 3. 4. 5. 6. How· do you intend to provide the required mechanical ventilation within the new R & D room as per UBC Section 1202.2.1. Why are there no lights or receptacles shown within the new R & D room? See sheets E-1 & 'E-2 of the plans. Provide a note on the plans indicating whether any hazardous materials will be stored and/or used within the building which exceed the quantities listed in UBC Tables 3-D and 3-E. Provide a complete description of the activities and processes that will occur in this tenant space ( R & D room and warehouse with extraction exhaust) should be provided. A listing of all hazardous materials should be included. The materials listing should be stated-in a form that would make classification in Tables 3-D and 3-E possible. The building official may require a technical report to identify and develop methods of protection .from hazardous materials. Section 307.1.6. END OF REVIEW Carlsbad 060791 $729/06 To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Chuck Mendenhall at Esgil Corporation. Thank you. .,. ,: ~ .. ,. Carlsbad 060791 3'/~9/,ll6 .. VALUATION AND PLAN CHECK FEE JURISDICTION: Carlsbad PREPARED BY: Chuck Mendenhall BUILDING ADDRESS: 2726 Loker Ave. West PLAN CHECK NO.: 060791 DATE: 3/29/06 BUILDING OCCUPANCY: B, Fl, SI TYPE OF CONSTRUCTION: V N BUILDING AREA Valuation Reg. VALUE 'PORTION (Sq.Ft.) Multiplier Mod. Tl 1000 34.37 .. -.. . , .. " .. .. .. . • Air Conditioning .. -· .. Fire Sprinklers ··TOTAL.VALUE · Jurisdiction Code cb By Ordinance Bldg. Permit Fee by Ordinance I • I Plan Ch~k.Fee by Ordinance / • I Type of Review: 0 Complete Review D Structural Only · D Repetitive Fee ~ Repeats Comments: D Other D Hourly J . I Hour * Esgll Plan Review Fee ($) : 34,370 34,370 $270.791 $176.011 $151.641 Sheet 1 of 1 macvalue.doc ' PLANNING/ENGINEERING APPROVALS PERMIT NUMBER CB tJ b .o J:l f DATE ------- ADDRESS )-?,:YG {c;/ee& /1.l/f. "RESIDENTIAL RESIDENTIAL ADDITION MINOR ( < $10,000.00) -. PLAZA CAMINO ·REAL CARLSBAD COMPANY STORES VILLAC& FAIRE COMPLETE OFFICE BUILDING . OTHER ,....,,......-~~,~.J.l.·~m---· :?:,_-.::......~~-...=.....;_-___::;_· _______________ _ Carlsbad Fire Department Plan.Review Requirements Category: Date of Report: 03-24-2006 Name: TI,COMM ~ . Reviewed by: ----r-~-1-~--- Address: Permit #: CB060791 Job Name: Job Address: POWERMETALTECHNOLOGIES 2726 LOKER AV WEST CBAD Hf00ifl1Pts1!111!1 'flw item you h&:c sabnriHcd func:is:: is incomph:bc. ht tlis time, Uris u:ffcc cmnfot 0dcqaatd5 conduct an :is:: to dctciminc coniplisntc :.itb tits appliealds cotles mt&'u stsnt1:Mtl8t J?ht.!11 11: i1111 o;acfalty aH conmioots attathtd. Plcass nsabnit tl2:p ujJsssci5 plmm mds'or BfJteiiintfu2s, ::itlt 1}1mtgH llduuied", tsfrfa effioe ii• Hnirr •• 1pp11: al: Conditions: Cond: CONOOOl 194 [MET] ~ffitb~~THIS PROJECT HAS BEEN REVIEWED AND APPROVED FOR THE PURPOSES OF ISSUANCE OF BUILDING PERMIT. THIS APPROV At IS SUBJECT TO FIELD INSPECTION AND REQUIRED TEST, NOTATIONS HEREON, CONDITIONS IN CORRESPONDENCE AND CONFORMANCE" WITH ALL APPLICABLE REGULATIONS. THIS APPROVAL SHALL NOT BE HELD TO PERMIT · OR APPROVE THE VIOLATION OF ANY LAW. Entry: 03/24/2006 By: gt Action: AP 10/141.0.S 1-kJ.7 .fAX 760 9314850 HQ GLO~AL WO:RKPLACES zsd " zoo 'd '. c~. 'l.l.{51- SANDIEGOB:EGIONAL ~~\- OFFJCI! USl!_OHLY ~ ~ ~ SC\C..1 HAZARDOUS MATERIALS QUESTIONNAIRE • .Di\'te: I / J !'ISSMll!Of'IOllt~ GP~tt~;~-.. = ~ .. APal v~vO.l.0909..L Tu'l31A1~3M0d. dg£:i70 90 £~ Jd'v' ~v go:tl 03M ~oo?i-og-~nv City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 09:18-2006 Plan Check Revision Permit No:PCR06154 Job Address: Permit Type: Parcel No: Valuation: Reference #: Project Title: Applicant: TONI PINON 858 549-8455 Building Inspection Request Line (760) 602-2725 2726 LOKER AV WEST CBAD PCR Lot#: 0 Status: Applied: 2090812800 $0.00 Construction Type: N_EW Entered By: Plan Approved: Issued: POWER METAL TECH-MECH REVISION Inspect Area: Owner: FENTON HG COMPANY 7577 MISSION VALLEY RD SAN DIEGO CA 92·108 Plan Check Revision Fee Additional Fees Total Fees: $120.00 Inspector: Total Payments To Date: $120.00 Balance Due: FINAL APPROVAL Date: Clearance: ISSUED 08/30/2006 RMA 09/18/2006 09/18/2006 $120.00 $0.00 $0.00 NOTICE: Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively . referred to as "fees/exactions." You have 90 days from the dale.this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in conn~ction with this project. NOR DOES IT APPLY to any fees/exactions of which vou have nreviouslv been niven a NOTICF similar In !hi~ or as to which the statute of limitations has nreviouslv otherwise exnired. AUG-30-2008 WED 08:25 AH CITY OF OARSLBAD FAX NO, 760 602 8658 P, 02 FOR OFFICE USE ONLY · Pl:RMIT APPLICATION CITY OF CARLSBAD BUILDING DEPARTMENT 1835 Faraday Ave., Carlsbad, CA 92008 PLAN CHECK NO. fC.B. Ob /.~'-f &ST. VAL., __________ _ Plan Ck. Depolft _______ _ Validated av, ________ _ D~e. ___________ _ .i..hMA• :---~ ----~.&~:.~ ~-.p ·~~ ·-·~---· c:r.r-~..:..otw· Addr• City 1111, 't: I .......-, ••••• ~~!1~~~~~~.li:-~~~t~ ta-. 7011.1 ..._ and PIDflllloN coa: NIY Clly er c.&.My Wflld\ '*ll*M • plfflllt III ll6lllllflllll, lllcar, lfflfll'OVa, lllffllllltb w nsatr any llt!Uet\N, pi1or ,~ Its ~ uo ,..,_ Vlt .,...__ ,.,. Mlrlh pennll • rn. • llialled ~ 1h11 tie 11 JIHI\MII jll.llUIM ta Iha prolllllcull of N Conu-.-ctor'• l.laal'oft u,.w IC'lllpw a, II0!11mtndint 'Wi1h S.lltiarl 7000 lit Oimian 3 af 1h11 lllllilMII lftll l'NlflhiOna (:ode! ar wi Ill II 1o1<1m.,t ""'6rrvm, Ind tha ballt for w 11W191d oxemlKIOn, lvr,"' tlon of~ 7011.~ by 1111y ~ fo, • l"Wffll't ~Ula wialllll 10 • clvll Nntl'tY of nat more than fiva hllndml dalan (HOOD. AddrlU . ~w/Zip . T.tnh-I u ... c1u1 __ ::::e, ____ _ C"!IY ""9Jn .. LieeMI I \~ Nllllt . Adlnn City Stwtw/Zip .st•t. Lk9nsa , ".\U,.5'54 . Iii :-• .. . · ~~~K~=--~~.-~~f~~i-::a;;.:::'~~il~~~t;~~ffi Warbt&' ComPM!Atian Dlclwtlon: I twi,uv affirm !NW jlll'llftl/ 6'-.i*PY am1 Ill*" flllowlAar olecla,-tiorta1 ~ vt Ind wilr IMinljlifl • Offllflcete vf -,it to Mlf.ffilute fOr -*••' Dllfflplllel1IOI\ IA pravidad by S~OI\ 1'700 Of Iha lllllar Code, fo, 11"1a parfDnMnCe af Gtk fDr which 'lflla ,:i.tl'mh Ii laulid. . . i'IIJ-ya·wml 'NlR mlinbin Wffllt~ OlllnpWlalion.. 11 r4111111tH by liaatlon 3700 of 1'111.11111' Cada. far 1111 perfotrn11111a af thll work for wNi.h 1hl.r pwmit i. iNUtd. My worltrl~e~ ~ 111d f/lfO'f Namrin: , , l,-ann ~U, ~\.te-4,INS:a I PollCVN•: -~ ... ,. !THIS SECTION raD :;:.;MIT'ID1f11S Pl!llttllT II POil ONli: HUNDIU!O POI.LAM (t1001 Oil WI) CJ camRC!&Tll a. ~Nt I Nltlfv IIMlt In Iha .....,,,..PIN flf Ille wale f« whldl ..... .-m1111 laMJlld. I 111\all now: amplllV any Ptrl0I\ in any manrier IO M to haam, aullilcl to '1111 WOIUd lllfllM1C,n Lawa at Clllftmll. '· WAIINtNG, ,..._ Ill ....... Nilfnl' CJJ11..ii••...,... II 11hla•, 111111111111 ujNC _. 1.....,_ to Cllffllftll l'.tlllftla• -,d clvl 'INI up to 1111,1 luldrt,d 1MilHnd .... tt,00.0 , NII ef llll!!!IIMllllllll!f; .... 11 .. .,...._ ,-111 Silllllan 3701 of lhl '-or aadll. lln'Clml and ~I ftet, BIGN-'TUM illC'. _-. _ DATE-, _l0,~5-!g. ~ _ . ~ . -~~----~~-I iJalllN ~w fcrr tftl fall•willl IIINII: · CJ I, II O 'Iha proptrlY 0t 9ffiP[oylas 'MIii MIU U tNl, .. ~Ion. wll da the waitt Ind Iha .lll\lafUl'II Ill l'IOf lntll'ldld Ill' 11ff•ra<1 fot tile !Sac. 7044, • and.Pmllliantl Codi! The ConlncnDr'a UDIIIN I.I" dDu not WIV It 1ft ~ of prapertv who build• ar irnprovN lhwaan, and who GOtll ,uc11 wutt hlfflHlf or W.llfh hi• awn -,...,._, ~ 1hal aKII impn,,ttn.,.. er. nm tmlnCfed ar orfllN far••· If, how.var, 1ha bialdlllSI or l~ant is IIClld wldlln Ofll ytlr crf ,:~tlon, 11'11 aWllll'W4« wtl hlva tha bllf'INI\ Of lll'GWIIJ m ha did nOt bui(cl,,,,. Nllf'fOY• for lf,a ~ q,f Mlt), 0 I, II OWMI Of lhe PfllPllrtV, tl'A ...rwlv ----with INlllllllld Nfttnlcrlllra 1:11 Olll1ffllCI tl\a prajaot tl•ci. ?044. lulln--, l'l'Of9INlillnl& ~_.; Th• Conmcalf't UCW1 Law daas IIOt llpPly ra III tl\l/N' Of praplrty WM 11111111 ar ffl'lllfOIIM itltlffn, .ind oon1,.;11 1'9r 4Ndl ~ wit!\ contrutotlt) lil:8lllllld pwa.iallt 16 Iha C-IIIMIW'• u-.._,, , ' 'CJ I am~ lllldlr,~on _ hsln• .nd Pr1t1-lciftl ~• tor VII• !Mllll'I; 1. I ,.-.ry pl,m to'"'""'' lhl,mlrJIK' IH• WIii IIIIWIIIIS ftt oonalnlCtlon oi tha prapaud DrOiltnY lmpravament. D Yi& ONO 2, I ll*V• / tt-.1111 nou tipn an ·•101111tn f1111 • llulldlnt pwmll ror 'Ill• PfOIIIIUII Wlll'IC, 2. 1 hwe -.tl'IIIIIN,wltll 'Iha fo#llwlllf ..-a (llm\)·io Jl(Ovldl tha prllPOffd OOl1ltnlDtlon ffneklcfjt na111• I •"11rtu / phnnl numb.or J contmCUlfl license numllait: 4, I pla1110 Pllvlda panfans of 1111 w•k. bllt 111..,. hhd w follo;wln11 11n11T1 • ~. Wlltl'MI and pmvldt tlla major worlc Pnct11cte namti I •dcltNa f pti-llUl'lllltt I aan1rl1Gtars lietnHl'lllffll!tfl:, ______________ _;_.,..._ __________________ _ I. r ~ Pl'OVICI• t111mra vf ,h• wo,1r, llfff I ftaVI amitnaied IJwNl tha falJowlnt pmaana to pr1!\44a t111 work rnc&eaitd (lnclud1 namt / efkf,.. J phano t111mblr / t)l)I !JtWgfM• . PROPIUITV OWNIIISIONATUIII ____________ ..,.....________ llATl':":"!"'~=-=-=---i----..,.,....,....,..,, lltiil!l!.;.::.ll. .. ,1 ...... ~$:a;!'W:r.,._.."h'l=i..~..,;r,--,~;:.;.:..;;.;,,,...~"l!I:;~; ,..-., .. ~~ ii~-...11~ • .-.,ii~l~lfli~ 11 thl ,__ rill Muto INlldlno occupaffl raqu1r.-to allllllit I buelfte& plan, !NWl,ly h_nl._ m1tet11i. ~•lkin form Dr dtlt ma11q11mant •114 p,evantian praQr1nua1dar StcdoM 21110lr, 25Hhr 25134 of aw Prnlav-Tlllnlt"tt__,dlll.ll 8~ Aaca\lnt Act? C 'IQ Cl NO It ft -,iicant fl(~ Mllldlnf llCCIIJllll'I NrllUfnll( ta ~ a parmit from 1hA. plllhnleft -...1 dlmot _, air l(llll(lty 11\tnqamMK dlatrlclf O YIS O ND 1, 111e fadllty to .. -~-within 1,aoo ,_of.,. ewtat ~ ot • n:hool llit1'1' D YE!S Cl NI) IP MY GP TttlANSW!III Alli YU, A PINAL CElTIPSCATt OF OC~ANCV 14AY Mor llf! IHIJED UNWS ntE APPUQANT HAI W!1i1'. OR Ill MiE11NG THE RBWl!llllaTI o, Tltl DfflCI! OP alEl~Y IIQMelll Me THI! Ml POLL.UTIGN CONTROL.DIITIUCT. . t.'LW:.iMM'~.lf\t~~~li!~~--!"~~~';'~;.;'tNt":~~~~;:;:,i-~~-~~\~.::t,,1'it~'M~:!SJ1,li.!'.:;,.:.•;:~ ~-~it:=!•""""""<111'n:~......-... ..._~.".,_.,~~ ... :,.,;.m.NWT.f.Het,:c;r-'",w.,.., I .ts..-v llfllffl\ 11'1111hllft la I ~ ltnefl!f lQIIIIGY fot 1119 ~ of 'OIi ~ fllf 111!1~ ffit P1riM ii INl!td JliR, 3017Cil <:mJ Cail•!, 1-l!NDER'S NAMI 1 otnifr tha\ 1111v• rud 'lhw .,.._""' Ind atata '11111 Iha urwt 'lnfotftldan 11 CClffffC •ncf that m• Jnf111111dlol'I ill'I t1u1 1111111 la acaurace, I 111n111 to an,i,Jv with Ill c:if.'{ «cl!Mnl:N MCI ltni II• Nlrif,1 1• ~ ~ I '*'*Y audlalfztl rapt1Nnt11ivu cir t.ba CIIII ltf Clrlllbld 10 1111• upon thlr lblMI l'l'llfttlonllll Pl'QPlltV flll' ~ IIUfPNII. I AUO A-TO SAVE. INDIIINIFY MID __. HAl'IMLHI THI C:JTY a, CAAL88AP AGAIN&T .1W. LIAIILITIQ •. .naD•fl nw: OOSTS MU IXPINtli WHICk MAY .. MV WAY ACCMJl·AGAINIT IAIP c;ny .. CGNflQUMClil OFTHI IIWfTING OF Tta w. oiHAi Ai, OIHA plrlllll II,.....,. ma:ivaslant cw.-li'O· ... 11111 MO!hlon ar CIIMtl'IICliOn af IIINl:llllfta vvw 3 Rl(fH In hllllht, DP~TIOl'ii £vary pennlt ,._, by Iha buMV IIINMr 1M pmilianl or til QodO lhd explnt by lnNlion 1111d tllllOtm 111111 ind veld I Ulll bl4ldltl9 ot WOik IWflle"-111V aii:t, l*ffllt II nol oorrlfflOIW!B.5ilalllljl1 1 f Cllllit of Slld't pa,mlr orlf · or wat!C ~wlt"1rtuo by aiKlh 11""!111t l11u1pended or abcll!donlld a\ any 1'ml ldllrtlla wodl Iii com, .... ....,,.-a 108,; 0ade).. · APJIIJCANT'S ISIQNATURI! -~;...c~~-:;r~~l::::::.....IIE:::7'.!~.,________ OATE pt,>·A<x-ti.~ f'INl(r fllnana ., EsGil Corporation In <Partnersliip witli. qwemment for <Buifding Safety DATE: 9/14/ 2Q.06 .JURISDICTION: C~rlsbad PL,.AN CHECK NO.: 060791/PCR06154 PROJECT ADDRESS: 2726 Loker Ave. West SET:REVI PROJECT NAME: Powermetal Technologies, R & D Enclosure 0 FILE I The :plans transmitted herewith have been .corrected where necessary and substantially comply with the jurisdiction's building codes. D The .plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below·are resolved arid checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil C91iporation until corrected plans are submitted for recheck . . D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been. sent to: I Esgil Corporation staff did not advise the .applicant that the plan check has been completed. Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Telephone#: Date contacted: (by: ) Fax #: Mail Telephone Fax In Person IZJ REMARKS: Addition of 1 additiot1al exhaust fan. By: Eric Jensen Esgil Corporation D GA D MB D EJ D PC Enclosures: 9/5 trnsmtl.dot 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858) 560-1468 + Fax (858) 560-1576 Carlsb~d 060791/PCR061S4 9/14/2006 VALUATION AND PLAN CHECK FEE JURISDICTION: Carlsbad 060791/PCR06154 PLAN CHECK NO.: PREPARED BY: Eric Jensen DATE; 9/14/ 2006 BUILDING ADDRESS: 2726 Loker Ave. West BUILDING OCCUPANCY: ·BUILDING AREA PORTION (Sq.Ft.) Air Conditionino Fire Sprinklers TOTALVALUE Jurisdiction Coda cb -· .. ~11 .19_94 USC Building Permit Fee.~ · -19-94 UBC_Pla_n Oleck-_f'ee ___ --' ________ ! 1 _.t TYPE OF CONSTRUCTION: Valuation· Reg. VALUE Multiplier Mod. . By Ordlnanc:e Type of Review: D Complete Review D Structural Only D Other 0 Hourly 1] Hour* l!stlll Pl-Review Foe Comments: Sheet 1 of 1 macvalua.doo soo/ sao·a tlO~# ($) l s120.oo] $96.001 to:oo oooz·so·aas lO/-l4f0S Ha'T fAX 7BD 9UH50 RQ GL0:8."1:-WO:RIPLACES ~. . c~ ~'<52. SANDIEGORBGtONAL ~~,- HAZARDOUS MATERIALS QUESTIONNAIRE Sf!.ONLY UPl=,N: ~<P,SC\G.:{ •~-e • I J ' ~~¥1;/As- o ~~ ' • £:1\'1'.1;: vLVO.l.0909l 7Vl3W~3MOd' dg£:t,O 90 £~ JdV ~v go:ll a3M 9DOl-os-5nv r ·-. ·tt Jim Bowen From: Sent: To: Cc: Jim Bowen Ubowen@powermetalinc.com] Wednesday, August 09, 2006 11 :50 AM 'j orge@d esignbuildti. com' 'Ron Broth~rs' Pagel of l Subject: ICP Detail Information Exhaust System (jim B. w/ PowerMetal Tech) 8-9-06 Attachments: ICP lnfo.pdf Hola Jorge, Here's information (see attached also): 1. We analyze aqueous solutions (mildly ;3cidic) consisting of 100 ppm, or less, of Nickel, Palladium, Tin and/or Iron. 2. Operation is 2 hours, on average, per day (Monday through Friday). 3. Volume of liquid per 2 hours of operation is approximately 200 ml (cc). This is liquid that is consumed by instrument (atomized) and would be exhausted. 4. Heat Generation: 2300-3000 watts (8000-10000 BTU/hr). 5. Flow rate (exhaust) is 4200 Umin. (150 CFM). · Please copy this information Will. lf neeQ further information or have questions just contact me. Thanks for the support. Adios, Jim Bowen QA Engineer PowerMetal Technologies, l_nc. 2726 Loker Avenue West Carlsbad, CA 92010 (760)607-0432 Work (760)607-0414 Fax (619)994-8849 Mobile ************************************************************************** This email and any attachments contain privileged and confidential information intended only for the use of the addressee(s). If you are not an intended recipient of this _email, you are hereby notified that any dissemination, copying or use of information within it is strictly prohibited. If you received this email in error or without authorization, please notify us immediately by reply e-mail and permanently delete all copies of the e-mail and any attachments from your system. 8/21/2006 f~oblsy 64f{;; CB D{b79 I, ,., Perkin-Elmer JCP-OES instruments are complete systems, with the exception of the following items: suitable wo!'king area, exhaust vents, gases and regulators, cooling water, and a computer table or bench. These items must be pr-0vided by the analyst. The JCP-OES system consists of the main instrument, the computer controller ass(!mbly, and .a printer, the dimensions of which are given in Table 2. Suitable Working Area The environment in which any instrument is housed is an important consideration. The room temperature should be between 15 and 35°C (59-95 °F) wi!h a maximum rate of cha11ge of2.8°C (5 °F) per hour. The instrument should be located awav from direct sources of heat or cold. The relative humidity sh~uld be between 20 and 80%, non condensing. In order to minimize contamination problems, a relatively dust-free environment is necessary. Maximum dust levels should not exceed 36 million particles (0.5 mm or larger) per cubic meter of air. Failure to operate the instrument in a relatively dust-free environment will necessitate more fr e- .quent maintenance and couid, .eventually, damage the in- strument. As a reference, a normal, clean office environment would be 18 million to 36 million particles per cubic meter. Another: important consideratio11 is to locate the insh·ument in-an area free of con·osive fumes and excessive vibration. The Optima is on wheels and can be moved for service and preventative maintenance. However, a space of 45 cm (18 inches} behind the instrument is recommended. This space behind the instrument provides easy access for routine main- tenance. The heat dissipated directly into the room air by the Optima, when properly ventilated, is between 2300 to 3000 watts (8000 to 10 000) ~Tl!/hour. 'Exhaust Vent The Optima 3000 ICP-OES systems require two vents, one for the ICP torch and an additional vent for heat removal. from the RF power supply. The torch venting system is r e- quired to remove combustion fumes and vapors from the torch housh1g. Exhaust venting is important for a number of reasons: • h will protect laboratoiy personnel from toxic vapors that may be produced by some samples. • It wi.11 tend to minimize the effects of room drafts and the laboratory atmosphere on ICP torch stability. Preparing Your Laboratory for the Perkin-Elmer Optima 3000 Family of ICP-Emission Spectrometers • Jt will help to protect the instrument from con-osive vapors that may originate from the samples. • 1t will remove dissipated hea1 thal is produced by Lile ICP torch and RF power supply. WARNING: The use ofJCP-OES instruments without ade- quate ventilation to outside air may consiitute a health haz- ard. For e,tamp1e, the combustion of halogenated hydrocar- bons produces toxic vapors. Extreme care should be taken that exhaust gases are vented properlv. The venting system should provide the following flow rates: RF generator · 2800 L/min (JOO CFM) iCP torch 1400 L/min (50. CFM) Please note that the minimum required combined now rate is 4200 L/min (150 CFM) ifa single, branched system is used. At i 500 watts of RF power, the temperatures of tbe exhaust gasses upon exiting the instrument are: RF generator ICP'totch 80 oc (176 °F) 200 oc (392 °f) The blower capacity depends on the duct length and the number of elbows or bends used to install the system. If an excessively long duct system -0r a system with many bends is used, a stronger blower may be necessary to prnvide sufficient exhaust voiume. Alternatively, smooth stainless steel tubing may be used instead offlexible stainless steel tubing where flexibility is not required to reduce system friction loss or "drag." A length of !>mooth stainless steel ducting has 20- 30% less friction loss than a comparable length of flexible ducting. When smooth stainless steel tubing is used, elbows must be·used to turn corners. These elbows should turn at a center line radius of 150 mm with a maximum bend angle of 45 degrees to reduce friction losses, and the number of e !- bows should be minimized. Additional recommendations on the venting system include: • Make sure the duct casing is installed using fireproof co n- struction. Route ducts away from sprinkler heads. • Locate the blower as close to the discharge OL!tlet as poss i- ble. All joints on the discharge side should be ailtight, es- pecially if toxic vapors are being carried. • Equip the outlei end oftbe system with a back draft damper and take the necessary precautions to keep the ex- haust outlet away from open windows or inlet vents and to extend it above the roof of the building for proper dispersal of the exhaust. • Equip the exhaust end of the system with an exhaust stack to improve the overall efficiency of the system. • Make sure the length of the duc1 that enters into the blower is a straight iength at least ten times the duct di- ameter. An elbow entrance into the blower inlet causes a loss in efficiency • Provide make-up air in the same quantity as is exhausted by the system. An "ai11igh( lab will cause an efficiency loss in the exhaust system. • Ensure that the system is drawing properly by releasing smoke into ~1e mouth of the vent. A synthetic «smoke" can be generated by placing open bottles ofh y- drochloric acid and ammonium hydroxide in the proximity of the vent opening. • Equip the blower with a pilot light located near the i 11- strume11t to indicate to the operator ·when the blower is on. Vent Positions The RF generator exhaust port-located at the back, top co r- ner on the left hand side of the instrument-should be con- nected to the venting system using flexible exhaust hose (provided with the instrument.) The exhaust hose has a JOO mm (4 inch) ID. t 10.2cm (4 in.} t Figure 1. Vent for Optima 3000 ICP Torch The IC:P torch stack, located -011 the top, front section on the !efr hand side of the instrument, should vent into an extra c- tion vent. The bottom of the vent should be 7.5-12.5 cm (3-5 in.) above the.top of the torch stack. The dimensions of the exhaust vent are shown in Figure J: Gases for Optima 3000 Systems Argon is used as the ICP torch gas and the detector purge gas with the Optima 3000 sysrems. Nitrogen is used for the opt i- cal purge gas. The quality criteria for the argon and the n i- trogen are listed below, Specification Pulity Oxygen Water Nitrogen Hydrogen Hydrocarbons Areon ;:::99.996% .:5:5 ppm 91 ppm ~20 ppm Nitroeen ;::::99.999% :S:5 ppm :,;;5 ppm :51 ppm :51 ppm Either liquid or gaseous argon can be used with an fCP-OES system although liquid is recommended. The choice of liquid argon or gaseous argon tanks is determined primarily by the availability of each and the usage rate. Liquid a1:gon is usu- ally Jess expensive per unit volume to purchase, but cannot be stored for exte11ded periods. If liquid argon is used, rhe tank should be fitted with an over-pressure regulator, which will vent the tank as necessaiy to preveni the fank from becoming a.safety hazard. Gas transfer Jines from the argon tank should be contaminant free and not made of plastic. lfthe !CP-OES system isto be used in the 167-190 nm wavelength range, the optical path must be purged with e i- ther nitrogen or argon. Nitrogen is the recommended purge gas due to iis lower cost. Normal purge gas usage is either J L/min (low purge) or 5 Umin (high purge) (user selecmble) for nitrogen and 1.4 L/min or 7 L/min with argon. The detector is purged with argon and operates contint1ously. Since the detectors are cooled to -40 °C, a purge gas is nece s- sary in order to prevent condensation. Argon is required b e- cause of its thermal conductivity. This purge uses 1 L/min of argon. Gaseous argon tanks do not require venting and consequently can be stored for extended periods without loss. A tank of liquid argon containing 160 liters will typically last for a p- proximately 80110urs of continuous ICP running time. A tank of gaseous argon will last five to six hours of iCP ru n- ning time. The normal argon usage is 16-20 L/min with a maximum of25 L/min. A cylinder regulator which can be Ltsed with argon is available from Perkin-Elmer as Pa11 No. · 0303-0264. The regulator can be used with CGA 580 .or .. CGA 590 fittings.' Liquid ai·gori a11d riitrogen 111·a:{be·pu·i:-. chased from your gas supplier. The Optima 3000 ICP-OES systems include the hoses necessary for connecting the argon and nitrogen to the instrument (0,25-inch Swagelok). Shear Gas on Optima Systems with an · Axially-Viewed Plasma These versions of the Optima use a shear gas to remove the plasma plume and to keep the heat away from the optics. E i- ther cle.an air or nitrogen can be used for the. shear gas. The shel;lr flow is -18 L/min (-0,65 cubic foot/min) at a mini- mum of415 kPa (60 psig). While cylinders of compressed air can be used, an air compressor is more practical. Ho W- ever, the shear gas must be clean and dry, so the Optima a s- semblies include an air d1-yer filter and regulator assembly (0047-0652). The air hoses are supplied with 0.25-inch Swagelok fittings and the assembly mounts on the lab wall. ln humid environments, this may not be-adequate to ensure that the compressed air is dry. Additional filters or conden s- ers may be a necessa1y par! of the air supply system. Handling of Gas Cylinders and Other Suggested Safety Practices Notice: The permanent installation of gc1s supplies is the re- sponsibili~v qf the user and should co11form Jo /ocai saje~v and building codes. • Faste!1 all gas cylinders securely to an immovable bul k- head or a permanent wall. • When gas cylinders are stored in confined areas, such as a room, ventilation should-be adequate to preven1 toxic or explosive accumulations. Move or store gas cylinders only in a vertical position with the valve cap il1 place. • Locate gas cylinders away from beat or ignition sources. including heat lamps. Cylinders have a pressure-relief d-e· vice that will release the contents of the cylinder if the temperature exceeds 52 °C (125 °F). • When storing cylinders external to a building, the cyli n- ders should be stored so that they are protected against temperature extremes (inclllding the direct rays ofthc sun) and should be stored above ground on a suitable floor. • Matk gas cylinders clearly to identify the contents and status (full, empty, etc.). • Do not attempt to refill gas,cylinders. • Anange gas hoses where they will not be damaged or stepped on and where things will not be dropped on them. • Perfonn periodic gas leak tests by applying a soap solution to all joints and seals. • Never view the ICP torch directly without protective eye wear. Potentially hazardous ultraviolet radiation may be emitted. Ordinary safety glii,sses will, in general, provide sufficient protection, but additional side shields will insure a further margin of safety. Safety glasses will also provide mechanical protection for the eyes. · • JCP-OES instruments generate high amounts of radio fr e- quency energy in their RF power supply and torch boxes, \1/hich is potentially hazardous if allowed to escape. Safety devices and screening interlocks should not be bypassed or disconnected. • The power supply of an ICP-OES is capable of generating potentially lethal voltages. No maintenance should be perfonned by anyone other than a Perkin-Elmer Service Special isl or the customer's,own P_erkin-Elmer trained maintenance personnel. • 'Water lines should be located away from electrical con- nections. Condensation and possible leaks may create an unsafe situation if in proximity lo electrical conneciions. Drain Vessels A drain vessel (0047-0660) is supplied with the Optima 3000 ICP-OES systems. The vessel is made of plastic and is used to gather the effluent from the ICP torch, The drain vessel should be placed on !he floor in front of the JCP-OES. The drain vessel shouid NOT be stored in an enclosed storage area, The drain system should be checked regularly and re- placed when necessary. Should it become necessary to replace the drain vessel, it should be;nade from a material not likely to be attacked by samples being analyzed. Glass or other brittle materials must not be used, Location Typical!)~ the Optima is positioned with the compurer and printer next to the instrument on a bench or table. The table or bench for the computer and primer is not supplied with the instrument. The computer and printer must not be placed on the instrumei:it or ins,mment shelf n~----: //' ~ ::::_III I ~~ ~, :J~ 155.4 _cm j::i.J 1-----~--~J (61.2 in.) ~i l ,:~~ I ~~'I . 1 1 1n--, ~-,,n~, ~-~ i • ~~· ! I l ' I . I ' l J 101.0 cm _...< "1_ ~! , < (39.7 "·' ~ '~ ~ i '] 126.3 cm i l '"·""~) Figure 2. Optima 3000 Dimensions Services The ICP-OES is powered from one sing-le-phase, 200 -240 V (the transfonner is tap-selectable in increments of 1 OV), 3 0 A dedicated electrical line. It uses one Hubbell No. 2621 plug and one Hubbe'll No. 2620 receptacle, which are supplied with the instrument. For additional informa_tion on electrical requirements, please contact your local Perkin-Elmer Service personnel. The ICP-OES system requires a regulated source of filtered water for the purpose of cooling. The water supply should be filtered (free of sediment), have a pH between 6.5 and 8.5, be hardness free, and the flow rate should be a minimum of l L/min (16 gallons/ho~r) al a temperature between 15-25°C (59-77 °F) and an operating pressure between 200-550 kPa {30-80 psi). The lab must be equipped with a drain for the water with a back pressure less than 100 kPa (15 psi). -------·· _, ,_ ,, ____ '""' ., ,_, ffa suirable supply of water is not available. a recirculating system should be used. The Neslab CFT-33 or Neslab CFT- 25 can be used with the Optima 3000 systems. The Optima 3000 ICP-OES sysiems include the hoses necessary for con- necting the coolant supply to the instrument ( 0.25-inch SwageLok). Summary: Facilities Required Tables 1 and 2 provide the power requirements and dime n- sions, respectively, for the Optimn and its major accessories. Table 1. Services Required for Optima 3000 Systems T)le electrical supply requirements and approximate power consumption for the ICP-OES and major accessories are given in Table I. Perkin-Elmer instruments will normally o p- erate within a l 0% range of the specified voltage and within 1 Hz of the ·specified frequency, unless otherwise noted. lfthe power line is unstable, fluctuates in frequency or is subject to surges, additional control ofthe incoming power may be re- quired. A means of electrically grounding the instruments must be available. The Optima 3000 is a computer-controlled, floor mounted instrument with two exhaust vents, Gases Argon 485 -825 kPa 1.-25 Umin Nitrogen 200 -825 kPa 1 -5 Umin· Shear gas Air or nitrogen 415 kPa approx.18 Umin Coolanl 200 -550 kPa 1 Umin 15-25 °C (59-77 °F) Power Optima 3000 200 -240 V 50/60 Hz 30-amp single-phase Computer and Printer 115V 60 Hz or 230 V 50Hz Chiller: Nesfab CFT 33 115V 60 Hz 13-amp single-phase or 220/240 V 50Hz 6-amp single-phase Neslab CFT 25 115V 60 Hz 9.6-amp single-phase or 220/240 V 50 Hz 4.6-amp single-phase Table 2. Dimensions, Optima 3000 Systems and Accessories Length Product cm (inches) Optima 126.3 (49.7) with shelf Sampling Devices: AS-90 autosampler 42(16.5) Power supply 42(16.5) Other Neslab CFT 33 36.8 (14.5) Neslab CFT25 30.5 (12) Height Depth Power Weight cm (inches) cm (inches} watts ka (lb) 155.4 (61.2) 76 (30) 6600 454 (998) 101 (4Q) 37 (14.6) 24 (9.4) 3 (6.6) 18.2 (7.-2). 41 (16.1) 59.7 (23.5) 48.2 (20.5) 1500 57 (125) 50.8 (20) 42 (16.5) 1180 39 {85) KINELME~ The Perkin-Elmer Corporation, 761 Main Avenue, Norwalk, CT 06859-0012 U.S.A. Tel: (800) 762-4000 or (203) 762-1000 Fax: {203) 762-6000 Internet: http://www.perkin-elmer.com Bodenseewerk Perkin-Elmer GmbH, Postfach 10 17 61, D-88647 Oberlingen, Germany TGel: (7551) 810 Fax: (7551) 1612 All analytical instrument and systems manufactured by Perkin-Elmer are developed and produced under the quality requirements of ISO 9001. Printed in USA© 1997 The Perkin-Elmer Corporalion L-18878 May 1997