HomeMy WebLinkAbout2728 CHESTNUT AVE; ; CB941245; Permit10/19/94 12
Page 1 of
Job Address
Permit Type
Parcel No:
Valuation:
BUILD
: 50
1
: 2728 CHESTNUT AV
: RESIDENTAL ADD/ALT
167-392-10-00
27,918
ING PERMIT
Suite
Lot#:
Construction Type: VN
Occupancy Group: R3
Description: 297 SF ADDITION -
Reference#:
TWO STORY
Permit No: CB941245
Project No: A9401776
Development No:
9194 10/19/94 0001 01 02
C-PRMT 296.00
Status: ISSUED
Applied: 10/04/94
Apr/Issue: 10/19/94
Entered By: RMA
Appl/Ownr WORTHING, BROOKS
P.O.BOX 1041
CARLSBAD, CA 92018-
*** Fees Required ***** *
619-729-3965
Fees Collected & Credits * *
Fees: 472,00
Adjustments: .00
Total Fees: 472,00
Fee description
Total Credits:
Total Payments:
Balance Due:
Units Fee/Unit
.00 ;;
176.00
296.00
Ext. fee Data
Building Permit
Plan Check , '
Strong Motion Fee
* BUILDING TOTAL .
Enter "Y" for Electric Issue Fee >
Enter "Y" for Remodel >
* ELECTRICAL TOTAL
272.00
177 .00
3. 00
452.00
10.00 Y
10.00 Y
20. 00
1EARANCE
CITY OF CARLSBAD
2075 Las Palmas Dr., Carlsbad, CA 92009 (619) 438-1161
PERMIT APPLICATION
City of Carlsbad Building Department
2075 Las Palmas Dr., Carlsbad. CA 92009 (619) 438-1161
1. PLKM1I
From List 1 (see back) give code of Permit-Type: SFD
For Residential Projects Only: From List 2 (see back) give
Code of Structure-Type: SFD
Net Loss/Gain of Dwelling Units Q
2. PROJECT INFORMATION
PLAN CHECK NO. C$ ?^//c?45~~~
EST.VAL
PIANCK~3E
VALID. BY
J7.qW
8931 10/04/94 0001 01 02
C-PRMT 176-00
FOR OFFICE USE ONLY
Address 2728 CHESTNUT AVE
Nearest Cross Street P O n t i a C
LEGAL DESCRIPTION Lot No.Subdivision Name/Number Unit No.Phase No.
CHECK BtLUW IF SUBMITTED:
D 2 Energy Calcs D 2 Structural Calcs D 2 Soils Report D1 Addressed Envelope
ASSESSOR'S PARCEL EXISTING USE PROPOSED USE
DESCRIPTION OF WORK
SQ.FT. 297'
2nd Story Addition
# OF STORIES # OF BEDROOMS # OF BATHROOMS
3. LXJNTAL.I FfcKSON (.it ditterent trom applicant;
NAME (last name first) SAME
CITY STATE
ADDRESS
ZIP CODE DAY TELEPHONE
4. APPLIOAN1 HCONTRACIOR U AGENT FOR CONTRACTOR UOWNiR U AGtN 1 1-UR OWNhR
NAME (last name first) WORTHING INC. B.A. ADDRESS P.O. BOX 1041 .
CITY CARLSBAD STATE CA ZIP CODE 92018 DAY TELEPHONE 729-3965
5. PROPERII OWNER
NAME (last name first) GONZALES , BELYNN
CITY CARLSBAD,STATE CA
ADDRESS 2728 CHESTNUT AVENUE
ZIPCODE 92008 DAYTELEPHONE 434-2281/729-8565
6. CONTRAC1UR
NAME (last name first) WORTHING, INC. B.A.
CITY CARLSBAD STATE
STATE LIC. #
ADDRESS p.Q. BOX 1041
ZIPCODE 92018 DAYTELEPHONE 729.3955
LICENSE CLASS R1 CITY BUSINESS LIC. # 549200
DESIGNER NAME (last name first) WQRTHINGf BR(X)KS
CITY CARLSBAD STATE CA ZIPCODE 92018
P.O. BOX 1041
DAYTELEPHONE 729-3965 STATE UC. # R-'
7. WORKER!? COMPENSATION
Workers' Compensation Declaration: I hereby affirm that I have a certiticate or consent to self-insure issued by the Director of Industnal
Relations, or a certificate of Workers' Compensation Insurance by an admitted insurer, or an exact copy or duplicate thereof certified
by the Director of the insurer thereof filed with the Building Inspection Department (Section 3800, Lab. C).
INSURANCE COMPANY STATE FUND POLICY NO. 229-6537 EXPIRATION DATE 01/95
Certificate ot Exemption: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner
so as to become subject to the Workers' Compensation Laws of California.
SIGNATURE DATE
8. OWNER-BUILDER DECLARATION
Owner-Builder Declaration: 1 nereoy attirm tnat 1 am exempt from the Contractors License Law tor me lollowing reason:
D I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or
offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds
or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended
or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden
of proving that he did not build or improve for the purpose of sale.).
D I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions
Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects
with contractor(s) licensed pursuant to the Contractor's License Law).
D I am exempt under Section Business and Professions Code for this reason:
(Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish, or repair
any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the
provisions of the Contractor's License Law (Chapter 9, commencing with Section 7000 of Division 3 of the Business and Professions Code)
or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit
subjects the applicant to a civil penalty of not more than five hundred dollars [$500]).
SIGNATURE DATE
COMPLETE THIS SECTION FOK NUN-KESIDliNT1AL BUILDING PERMITS ONLY:
Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and
prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act?
D YES D NO
Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district?a YES a NO
Is the facility to be constructed within 1,000 feet of the outer boundary of a school site?
D YES D NO
IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED AFTER JULY 1,1989 UNLESS THE APPLICANT
HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT.
9. CONSTRUCTION LENDING AGENCY
I hereby attirm that there is a construction lending agency lor the performance ot the work tor which this permit is issued (Sec 3097(i) Civil Code).
LENDER'S NAME LENDER'S ADDRESS
10. APFLICAN1 CERllrlCAllON
I certify that I have read the application and state that the above intormation is correct. I agree to comply with all City ordinances and State laws
relating to building construction. I hereby authorize representatives of the City of Carlsbad to enter upon the above mentioned property for inspection
purposes. I ALSO AGREE TO SAVE INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS
AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT.
OSHA: An OSHA permit is required for excavations over 5'0" deep and demolition or construction of structures over 3 stories in height.
Expiration. Every permit issued by the Building Official under the provisions of this Code shall expire by limitation and become null and void if the
building or work authorized by such permit is not commenced within 365 days from the date of such permit or if the building or work authorized by
such permit is suspended or abandoned .at any time^after the work is commenced for a period of 180 days (Section 303(d) Uniform Building Code).
APPLICANTS SIGNATURE^/ UtAllI (2-^ DATE: f' ~'~ '
WHITE: Rile YELLOW: Applicant PINK: Finance
'* CITY OF CARLSBAD
.-*•' INSPECTION REQUEST
PERMIT* CB941245 FOR 06/06/95
DESCRIPTION: 297 SF ADDITION - TWO STORY
TYPE: RAD
JOB ADDRESS;
APPLICANT:
CONTRACTOR:
OWNER:
2728
WORTHING,
CHESTNUT AV
BROOKS PHONE:
PHONE:
PHONE:
INSPECTOR AREA PD
PLANCK# CB941245
OCC GRP R3
CONSTR. TYPE VN
STE: LOT:
619-729-3965
REMARKS: MW/DIANA/729-3965
SPECIAL INSTRUCT: AM PLS
INSPECT
TOTAL TIME:
CD LVL DESCRIPTION
19
29
39
49
ACT COMMENTS
ST Final Structural
PL Final Plumbing
EL Final Electrical
ME Final Mechanical
***** INSPECTION HISTORY *****
DATE DESCRIPTION
030395 Final Combo
120994 Interior Lath/Drywall
120994 Exterior Lath/Drywall
120594 Insulation
120594 Rough Combo
112294 Frame/Steel/Bolting/Welding
112294 Rough Electric
112294 Rough/Ducts/Dampers
112294 Frame/Steel/Bolting/Welding
112294 Rough Electric
112294 Rough/Ducts/Dampers
110394 Roof/Reroof
102594 Ftg/Foundation/Piers
ACT
CO
AP
AP
AP
AP
CO
CO
CO
CO
CO
CO
AP
AP
INSP
PY
PY
PY
PD
PD
PD
PD
PD
PD
PD
PD
PD
PD
COMMENTS
HANDRAIL & SMOKE ALARM
ESGIL CORPORATION
9320 CHESAPEAKE DR., SUITE 208
SAN DIEGO, CA 92123
(619) 56O-1*68
DATE://A I
JURISDICTION: ;
PLAN CHECK NO: _
PROJECT ADDRESS:
PROJECT NAME:
cir
SET:
-2. ~7 2 CH£S~TNt>T
<Q7URISDICTIO§)
JPLAN CHECKEK
JFILE COPY
QUPS
QDESIGNER
SP£>
D
D
The plans transmitted herewith have been corrected where
necessary and substantially comply with the jurisdiction's
building codes.
The plans transmitted herewith will substantially comply
with the jurisdiction's building codes when minor deficien-
cies identified pn. "the g-H-<xc/H>2 sk-eei* are resolved and
checked by building department staff.
The plans transmitted herewith have significant deficiencies
identified on the enclosed check list and should be corrected
and resubmitted for a complete recheck.
The check list transmitted herewith is for your information.
The plans are being held at Esgil Corp. until corrected
plans are submitted for recheck.
"1 The applicant's copy of the check list is enclosed for the
-• jurisdiction to return to the applicant contact person.
| The applicant's copy of the check list has been sent to:
3%.. A \/\//7K/^7/>>^ Ihc '
O
Esgil staff did not advise the applicant contact person that
plan check has been completed.
Esgil staff did advise applicant
been completed. Person contacted>
Date contacted:
REMARKS;
he plan check has
lephone
\
By; £>A V \ P YA O Enclosures;
ESGIL CORPORATION ip
DGA DCM DPC
L4*>;\*> 0v\_•fl an
^
7s &
d /
^O
n AS )
I'D
Date:Jurisdiction
Prepared by:
VAD VALUATION AND PLAN CHECK FEE
Q Bldg. Dept.
p Esgil
PLAN CHECK NO. 74 ~
BUILDING ADDRESS
APPLICANT/CONTACT _
BUILDING OCCUPANCY __
TYPE OF CONSTRUCTION
PHONE NO.
-2>/ M*/ " DESIGNER PHONE
CONTRACTOR PHONE
BUILDING PORTION
\ \V\n\, ' *7fOlr/
£/
Air Conditionine
Commercial
Residential
Res. or Comm.
Fire Snrinklers
Total Value
BUILDING AREA
^9?
VALUATION
MULTIPLIER
^
@
<a
@
VALUE
^~7, 9/f
-
^7, 9tf
Building Permit Fee $_
Plan Check Fee $
COMMENTS!
SHEET ' OF /
12/87
City of Carlsbad
Engineering Department
DATE:
BUILDING ADDRESS: _
PROJECT DESCRIPTION:
ASSESSOR'S PARCEL NUMBER:
BUILDING PLANCHECK CHECKLIST
PLANCHECK NO. CB
7 -70 EST. VALUE
APPROVAL
The item you have submitted for review has been
approved. The approval is based on plans, information
and/or specifications provided in your submittal; therefore
any changes to these items after this date, including field
modifications, must be reviewed by this office to insure
continued conformance with applicable codes. Please
review carefully all comments attached, as failure to
comply with instructions in this report can result in
suspension of permit to build.
I IA Right-of-Way permit is required prior to construction
of the following improvements:
ENGINEERING DEPARTMENT
DENIAL
Please see the attached report of deficiencies marked
with O Make necessary corrections to plans or
specifications for compliance with applicable codes and
standards. Submit corrected plans and/or specifications
to this office for review.
By:_Date:
By:.Date:
By:.Date:
FOR OFFICIAL USE ONLY
ISSUE WWmPmW;
ATTACHMENTS ENGINEERING DEPT. CONTACT PERSON
I—I Dedication Application
CD Dedication Checklist
I—I Improvement Application
I—I Improvement Checklist
I—I Future Improvement Agreement
LJ Grading Permit Application
LJ Grading Submittal Checklist
U Right of Way Permit Application
LJ Right of Way Permit Submittal Checklist
and Information Sheet
I—I Sewer Fee Information Sheet
P:\DOCS\CHKLST\BP0001 .FRM
NAME:
City of Carlsbad
ADDRESS: 2075 Las Palmas Dr.. Carlsbad. CA 92009
PHONE : f6191 438-1161. Ext.
A-4
REV 05/11/94
2075 Las Palmas Dr. • Carlsbad, CA 92OO9-1576 - (619) 438-1161 -FAX (619) 438-O894
Vvy
BUILDING PLANCHECK CHECKLIST
SITE PLAN
/3rd^
D D 1. Provide a fully dimensioned site plan drawn to scale. Show:
A. North Arrow D. Property Lines Easements
B. Existing & Proposed Structures E. Easements
C. Existing Street Improvements F. Right-of-Way Width & Adjacent Streets
D 2. Show on site plan:
A. Drainage Patterns C. Existing Topography
B. Existing & Proposed Slopes
D D 3. Include note: "Surface water to be directed away from the building foundation at a 2%
gradient for no less than 5' or 2/3 the distance to the property line (whichever is less)."
[PeM985UBC2907(d)5].
On graded sites, the top of any exterior foundation shall extend above the elevation
of the street gutter at point of discharge or the inlet of an approved drainage device
a minimum of 12 inches plus two percent" (per 1990 UBC2907(d)5.).
D 4. Include on title sheet
A. Site address
B. Assessor's Parcel Number
C. Legal Description
For commercial/industrial buildings and tenant improvement projects, include: Total
building square footage with the square footage for each different use, existing sewer
permits showing square footage of different uses (manufacturing, warehouse, office,
etc.) previously approved.
EXISTING PERMIT NUMBER DESCRIPTION
P:\DOCS\CHKLST\BP0001.FRM Page 1 Of 4 REV 05/11/94
BUILDING PLANCHECK CHECKLIST
DISCRETIONARY APPROVAL COMPLIANCE
3rdy
D 5. Project does not comply with the following Engineering Conditions of approval for
Project No. i
Conditions were complied with by: Date:
DEDICATION REQUIREMENTS
D 6. Dedication for all street Rights-of-Way adjacent to the building site and any storm
drain or utility easements on the building site is required for all new buildings and for
remodels with a value at or exceeding $ -pursuant to Code Section
18.40.030.
Dedication required as follows:
Attached please find an application form and submittal checklist for the dedication
process. Provide the completed application form and the requirements on the
checklist at the time of resubmittal.
Dedication completed by Date:
IMPROVEMENT REQUIREMENTS
D D D 7a. All needed public improvements upon and adjacent to the building site must be
constructed at time of building construction whenever the value of the construction
exceeds |> -pursuant to Code Section 18.40.040.
Public improvements required as follows:
Please have a registered Civil Engineer prepare appropriate improvement plans and
submit them together with the requirements on the attached checklist for a separate
plancheck process through the Engineering Department. Improvement plans must be
approved, appropriate securities posted and fees paid prior to issuance of permit.
Attached please find an application form and submittal checklist for the public
improvements requirements. Provide the completed application form and the
requirements on the checklist at the time of resubmittal.
Improvement Plans signed by: Date:
P:\DOCS\CHKLST\BP0001.FRM Page 2 Of 4 REV 05/11/94
BUILDING PLANCHECK CHECKLIST
1stv/ 2ndv^ 3rcV1stv/ 2ndv^ 3rcV
D D D 7b. Construction of the public improvements may be deferred pursuant to code Section
18.40. Please submit a recent property title report or current grant deed on the
property and processing fee of $ _ _ _ so we may prepare the
necessary Future Improvement Agreement. This agreement must be signed, notarized
and approved by the City prior to issuance of a Building Permit.
Future public improvements required as follows: _ _ __
Improvement Plans signed by: Date:..
D D D 7c. Enclosed please find your Future Improvement Agreement. Please return signed and
notarized Agreement to the Engineering Department.
Future Improvement Agreement completed by:
Date:
D D 7d. No Public Improvements required. SPECIAL NOTE: Damaged or defective
improvements found adjacent to building site must be repaired to the satisfaction of
the City Inspector prior to occupancy.
GRADING PERMIT REQUIREMENTS
The conditions that invoke the need for a grading permit are found in Section 11.06.030
of the Municipal Code.
D D D 8a. Inadequate information available on Site Plan to make a determination on grading
requirements. Include accurate grading quantities (cut, fill import, export).
D D D 8b. Grading Permit required. A separate grading plan prepared by a registered Civil
Engineer must be Submitted together with the completed application form attached.
NOTE: The Grading Permit must be issued and rough grading approval obtained prior
to issuance of a Building Permit.
Grading Inspector sign off by: Date: •
D 8c. No Grading Permit required.
P:\DOCS\CHKLST\BP0001.FRM Page 3 Of 4 REV 05/11/94
BUILDING PLANCHECK CHECKLIST
%
MISCELLANEOUS PERMITS
9. A RIGHT-OF-WAY PERMIT is required to do work in City Right-of-Way and/or
private work adjacent to the public Right-of-Way. Types of work include, but are not
limited to: street improvements, trees, driveways, tieing into public storm drain, sewer
and water utilities.
Right-of-Way permit required for :
A separate Right-of-Way permit issued by the Engineering Department is required for
the following: '
D D 10. A SEWER PERMIT is required concurrent with the building permit issuance. The fee
is noted in the fees section on the following page.
D D 1.1. INDUSTRIAL WASTE PERMIT is required. Applicant must complete Industrial
Waste Permit Application Form and submit for City approval prior to issuance of a
Permit.
Industrial waste permit accepted by: Date:
P:\DOCS\CHKLST\BP0001.FRM Page 4 Of 4 REV 05/11/94
PLANNING CHECKLIST
Plan Check No. ™~ /~?M Address
Planner VAN LYNCH Phone 438-1161 ext. 4325
(Name)
APN:
Type of Project and. Use _
Zone i<£^7 Facilities Management Zone
« aa a
.C -C -C<J U U
i S S
lira a
(It property in, complete SPECIAL TAX CALCULATION
WORKSHEET provided by Building Department.)
Item Complete
% Item Incomplete - Needs your action
1, 2, 3 Number in circle indicates plancheck number where deficiency was
identified
Environmental Review Required: YES NO AC TYPE
DATE OF COMPLETION:
\
Compliance with conditions of approval? If not, state conditions which require action.
Conditions of Approval
D Discretionary Action Required: YES
DATE:APPROVAL/RESO. NO.
PROJECT NO.
OTHER RELATED CASES:
trac
Compliance with conditions of approval? If not, state conditions which require action.
Conditions of Approval '^__, ' '
California Coastal Commission Permit Required: YES NQ/X
DATE OF APPROVAL:
San Diego Coast District, 3111 Camino Del Rio North, Suite 200, San Diego, CA. 92108-1725
(619)521-8036
Compliance with conditions of approval? If not, state conditions which require action.
Conditions of Approval :
DD Inclusionaiy Housing Fee required: YES NO
(Effective'date of faclusionary^Housing Ordinance - May 21, 1993.)
croc:
s^nc
Site Plan:
Zoning:
1. Provide a fully dimensioned site plan drawn to scale. Show: North
arrow, property lines, easements, existing and proposed structures,
streets, existing street improvements, right-of-way width, dimensioned
setbacks and existing topographical lines.
2. Provide legal description of property, and assessor's parcel number.
1. Setbacks:'f
cfran
nnn
Front:
Int. Side:
Street Side:
Rear:
2. Lot coverage:
3. Height:
4. Parking:
Additional Comments
Required
Required
Required
Required
Required
Required
Spaces Required
Guest Spaces Required
£C> Shown ^6
<?.1' Shown )~7/
' — • Shown
f@~6r Shown oS~"
/ */nP 'ou SWJ^c — 7ix# Shown ^ ^ v>
^^O ^ Shown <^/
^- Shown ^ —
Shown
OK TO ISSUE AND ENTERED APPROVAL INTO COMPUTER 'AJ DATE
PLNCK.FRM
B.fi. WORTHING INC.TEL=1-619-729-0784 Nov 29,94 7:21 No.002 P.02
T* rtai MOO 29 -9<t Ol t
TH&A,
Engineering and Code Coiuultonte
2601 Vista Lago Tomoa
Escondido, CA 92029
(619)746-8112
• Structural Engineering
• Plan Cheeking
• Building Code CvrauMna
• T«te 24 Energy
FAX TRANSmiTTAL
PATE? \\-1ft+NUMBER OP PAGES BEING TRANSMITTED
(INCLUDING FAX TRANSMTITAL)
-I
TIME SENT:
TO;
COMPANY:r INC.
PHONE #
FAX )|t I
I (619) 746-5112
(619) 741-0736
SPECIAL INSTRUCTIONS:
l) f/Wfrfr g>(*/ ^fL Tfrfr pi y KGOf T*»** 0-
B.fl TEL: 1-619-729-0784
TH&fi' INC.
Nov 29,94 7:22 No.002,P.05 .
574 P02 NOU 29 '94 01:16-*' ttt i f r*"t i t4"-
TH&A, INC.Engineering and Cod* Consultant!
2581 Vista Lego Terrace
ndldo, California 92029
(619)746-5112
•MMTNO..OF,
OALCUtATlDBY.DATS-
DATf.
| \Ji+..faK*r£i~toJ. J." V>TT./^. i*-\r .-i
TH&A, me.
Engineering and Code Consultants
2581 Vista Lago Terrace
Escondido, CA 92029
(610)746-5112
STRUCTURAL CALCULATIONS
PROJECTS GDNZMES ACPrnCN (94-34)
2728 CHESHiOT AVE., CBRLSBAD
» SEPTEMBER 24, 1994
TH&Aj me.
Engineering and Code Consultants
2581 Vista Lago Terrace
Escondido, CA 92029
(619)746-5112
TH&A, me.
Engineering and Code Consultants
2581 Vista Lago Terrace
Escondtio, CA 92029
(619)746-5112
JOB.
SHEET NO..
CALCULATED BY.
CHECKED BY
SCALE
OF
DATE.
DATE.
,
TH&A, me.
Engineering and Code Consultants
2581 Vista Lago Terrace
Escondldo, CA 92029
(619)746-5112
JOB-
SHEET NO.-OF.
CALCULATED BY.
CHECKED BY
SCALE
r-tt.
DATE.
jMUSE&tec^g
M&me^Ml/l
TH&Aj me.
Engineering and Code Consultants
2581 Vista Lago Terrace
Escondido, CA 92029
(619)746-5112
TH&A, me.
Engineering and Code Consultants
2581 Vista Logo Terrace
Escondido, CA 92029
(619)746-5112
JOB AU
SHEET NO..OF.
CALCULATED BY.
CHECKED BY
SCALE .
DATE.
-_-:£_
I?
v f:
TH&A, INC.
Engineering and Code Consultants
2581 Vista Lago Terrace
Escondldo, CA 92029
(619)746-5112
LJJikk
A
_ —.
jgj
TH&A,iNc.
Engineering sand Code Consultants
2581 Vista Lago Terrace
Escondido, CA 92029
(619)746-5112
JOB.
SHEET NO.-OF.
CHECKED BY.
SCALE.
TH& A, me.
Engineering and Code Consultants
2581 Vista Lago Terrace
Escondido, CA 92029
(619)746-5112
JOB_:
SHEET NO .
CALCULATED BY.
CHECKED BY
SCALE
OF
DATE.
DATE.
~=ys?^t.7
_j ]
SHEAR WALL SCHEDULE
SYM, MATERIAL
A 1/2" GYP. BD.
UNBLOCKED
A 5/8" GYP. BD.
UNBLOCKED
A 1/2" GYP. BD.
UNBLOCKED
A 5/8" GYP. BD.
UNBLOCKED
A 1/2" GYP. BD. W/
BLOCKED EDGES
/\ 5/8" GYP. BD. W/
/ ° \ BLOCKED EDGES
A 7/8" STUCCO W/
PAPER BACKED
WIRE LATH
EDGE NAIL
16d NAILS SF
PER SCHE
•;A 3/8" STRUCT. II
/ °\ C-D OR C-C PLYWD.
f
A 3/8" STRUCT. II
C-D OR C-C PLYWD.
A 3/8" STRUCT. II
C"~D OR C~C PLYWD.
A 3/8" STRUCT. II
C-D OR C-C PLYWD.
A 1/2" STRUCT. II
C-D OR C-C PLYWD.
A 1/2" STRUCT. II
C-D OR C-C PLYWD.
A 1/2" STRUCT. I
NAILING
5d COOLER NAILS O 7" O.C.
F.N. ft E.N.
6d COOLER NAILS O 7" O.C.
F.N. ft E.N.
5d COOLER NAILS • 4" O.C.
F.N. ft E.N.
6d COOLER NAILS O 4" O.C.
F.N. ft E.N.
5d COOLER NAILS O 4" O.C.
F.N. ft E.N.
6d COOLER NAILS 9 4" O.C.
F.N. ft E.N.
16 GA. STAPLES O 6" O.C. O
TOP ft BOTTOM PLATES, EDGES
ft FIELD OF SHEAR PANEL
(E.N.) -^ PLYWOOD
fy ^ 2x RIM Ji
X .—- 16d NAILS
AGED — M5<l PER SCHEDULEr^wt.,1^ *-rf^ _ ?-* * tr\ <j\^1it-iJ \JI-L-:DULE \><!
( =><.^-— _™, ™=\ DBL TOP
B-N.-O
SHEAR TRANSFER' wy
2x4 BLOCKING
8d O 6" O.C. E.N. ft B.N.
12" O.C. F.N.
8d 0 4" O.C. E.N. ft B.N.
12" O.C. F.N.
8d O 2-1/2" O.C. E.N. ft B.N.
12" O.C. F.N.
8d • 2" O.C. E.N. ft B.N.
12" O.C. F.N.
10d O 4* O.C. E.N. ft B.N.
12" O.C. F.N.
10d * 3" O.C. E.N. ft B.N.
12" O.C. F.N.
10d O 2" O.C. E.N. ft B.N.
SHEAR TRANSFER
VALUE NAILING
50# / FT. 16d O 12" O.C. OR
A35 O 32" O.C.
50# / FT. 16d O 12" O.C. OR
A35 O 32" O.C.
75f / FT. 16d 08" 0:C. OR
A35 O 32" O.C.
75f /FT. 16d O 8" O.C. OR
A35 O 32" O.C.
75# /FT. 16d O 8" O.C. OR
A35 • 32" O.C.
75# /FT. 16d O 8" O.C. OR
A35 O 32" O.C.
180# /FT. 16d O 8" O.C. OR
A35 O 32" O.C.
SHEATHING
>T. OR BLK'G. -vJ
1
B.N. — «.£
PLATE "^ *
^— E.N.
/
^- A35 FRAMING
\ f SPACED PER
>sX,
ANCHOR
BOLTS
5/8"x1<5"
5/8"x10"
5/8"x10"
5/8"x1fl"
5/8"x1(?"
5/8"x1o"
5/8"x1o"
ANCHOR
SCHEDULE
SHEAR TRANSFER W/
METAL CUPS
260# /FT. 16d 0 6" O.C. OR
A35 0 24" O.C.
380# /FT. 16d O 4" O.C. OR
A35 0 16" O.C.
570# /FT. 16d C 3" O.C. OR
A35 O 12" O.C.
6400 /FT. 16d 0 2" O.C. OR
A35 O 9" O.C.
460# /FT. 16d O 3" O.C. OR
A35 O 12" O.C.
69Q# / FT. 16d O 3" O.C. OR
A35 O 12" O.C.
780# /FT. 16d O 2" O.C. OR
5/8"x10*'
5/8"x10w
5/8"x10*
5/8"x1o"
5/8MO*
5/8°xlo"
5/8"x10w
C-D OR C-C PLYWD. 12" O.C. F.N.
* NOTE:
SPACING OF ANCHOR BOLTS AND SHEAR TRANSFER NAILING
ARE REQUIRED ON BOTH FACES OF WALL
A35 O 8" O.C.
SHALL BE REDUCED BY HALF IF SHEAR WALL MATERIALS
TABLE NO. 25-O—NAILING SCHEDULE
CONNECTION
I . Joist to sill or girder, toenail
2. Bridging to joist, toenail each end
3 . 1 " x 6" subfloor or less to each joist, face nail
4. Wider than 1" x 6" subfloor to each joist, face nail
5.2" subfloor to joist or girder, blind and face nail
6. Sole plate to joist or blocking, face nail
7. Top plate to stud, end nail
8. Stud to sole plate
9 . Double studs , face nail
10. Doubled top plates, face nail
1 1 . Top plates, laps and intersections, face nail
12. Continuous header, two pieces
13. Ceiling joists to plate, toenail
14. Continuous header to stud, toenail
1 5 . Ceiling joists, laps over partitions, face nail
16. Ceiling joists to parallel rafters, face nail
17. Rafter to plate, toenail
18. 1" brace to each stud and plate, face nail
19. 1" x 8" sheathing or less to each bearing, face nail
20. Wider than 1" x 8" sheathing to each bearing, face nail
21. Built-up corner studs
22. Built-up girder and beams
MAILMG'
3-8d
2-8d
2-8d
3-8d
2-16d
16datl6"o.c.
2-16d
4-8, toenail or
2-16d,endnaii
16dat24*o.c.
16datl6*o.c.
2-16d
16datl6"o.c.
along each edge
3-8d
4-8d
3-16d
3-16d
3-8d
2-8d
2-8d
3-8d
16dal24'o.c.
20d at 32" o.c. at top
and bottom and staggered
2-20datendsandat
each splice
CONNECTION NAILING'
23. 2* planks 2- 16d at each bearing
24. Plywood and particleboard:!
Subfloor, roof and wall sheathing (to framing):
1/2" and less 6d2
l9/32"-3/4" 8d3 or 6d4
7/8"-l" 8d2
11/8". l>/4" I0d3or8d4
Combination Subfloor-underlayment (to framing):
3/4" and less 6d"
7/g°-l" 8d*
11/8"- U/4" 10d3or8d4
25. Panel Siding (to framing):
1/2" or less 6d6
5/8" M6
26. Fiberboard Sheathing:?
1/2" ,No. llga.?
6d3
No. 16ga.»
2S/32" No. llga.S
84.3
No. 16ga!9
1 Common or box nails may be used except where otherwise stated.
-Common or deformed shank. -
3Common. . .
••Deformed shank. (
'Nails spaced at 6 inches on center at edges, 12 inches at intermediate supports (10 inches at
intermediate supports for floors) , except 6 inches at all supports where spans are 48 inches
or more. For nailing of plywood and particleboard diaphragms and shear walls, refer to
Section 25 1 3 (c). Nails for wall sheathing may be common, box or casing.
'Corrosion-resistant siding or casing nails conforming to the requirements of Section 25 1 6
TFasteners spaced 3 inches on center at exterior edges and 6 inches on center at intermediate
supports.
•Corrosion-resistant roofing nails with 7/16-inch-diameter head and ll/2-inch length for 1/2-
inch sheathing and 13/4-inch length for 25/32-inch sheathing conforming to the require-
ments of Section 2516 (j) 1 •
^Corrosion-resistant staples with nominal 7/16-inch crown and ll/8-inch length for l/2-inch
sheathing and ll/2-inch length for 25/32-inch sheathing conforming to the requirements of
Section 2516 (j)l-
I PLYWOOD FLOOR AND ROOF SHEATHING WILL COMPLY WITH THE FOLLOWING:
TABLE NO. 25-S-1—ALLOWABLE SPANS FOR PLYWOOD SUBFLOOR AND
ROOF SHEATHING CONTINUOUS OVER TWO OR MORE SPANS AND FACE
GRAIN PERPENDICULAR TO SUPPORTS' •
PANEL
SPAN
RATING)
1.12/0
2.16/0
3.20/0
4.24/0
5.24/0
6.32/16
7.40/20
8.48/24
PLYWOOD
THICKNESS
(Inch)
5/16
3/l6. 3/8
3/16, 3/8
3/8
13/J2, '/2
IJ/32, '/2, '»/32,
'/8
"/12, 5/g. "to,
>/«, 7/8
*%2. >/4, '/«
ROOF2
Minimum Span
(In Inches)
Edges
Blocked
12
16
20
24
24
32
40
48
Edges
Unblocked
16
24
28
32
36
Load (In Pounds
per Square Foot)
Total
Load
135
80
70
60
60
55
40-'
40*
Live
Load
130
65
55
45
45
35'
35"
35'
FLOOR
MAXIMUM
SPAN*
(In Inches)
0
0
0
0
0
16*
20"
24
These values apply for C-C, C-D, Structural I and II grades only. Spans shall be limited to
values shown because of possible effect of concentrated loads.
'Uniform load deflection limitations I/IHU of the span under live load plus dead load. '/MO
under live load only. Edges may be blocked with lumber or other approved type of edge
support.
*Span rating appears on all panels in the construction grades listed in Footnote No. I. .
'Plywood edges shall have approved tongue-and-groove joints or shall be supported with
Mocking unless '/4-inch minimum thickness underlayment. or I'/j inches of approved
cellular or lightweight concrete is placed over the subfloor, or finish floor is --Vo-inch
wood strip. Allowable uniform load based on deflection of VMO of span is 165 pounds per
square foot. .
for roof live load of 40 pounds per square foot or total load of 55 pounds per square foot,
decrease spans by 13 percent or use panel with next greater span rating.
•May be 24 inches if 2V.i2-inch wood strip flooring is installed at right angles to joists.
'May be 24 inches where a minimum of I'/: inches of approved cellular or lightweight
concrete is placed over the subfloor and the plywood sheathing is manufactured with
exterior glue. •
'Floor or roof sheathing conforming with this table shall be deemed to meet the design
criteria of Section 2516.
JOB.
WE.
Ttl&A SHEET NO — ! • or.
Engineering and Code Consultants CALCULATED ev_JL±L OATE 4 -24
1941 Continental Lane
EscoodWo, CA, 9202? CHECKED BY DATE
(619) 746-5112 SCALE
SPECIFICATIONS/NOTES:
GENERAL:
1 ALL DETAILS, SECTIONS AND NOTES SHOWN ON STRUCTURAL DRAUINGS
ARE INTENDED TO BE TYPICAL AND SHALL APPLY TO SIMILAR SITUATIONS
ELSEWHERE U.N.O.
2 ALL DESIGN AND CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE
LATEST ADOPTED EDITION OF THE UNIFORM BUILDING CODE.
3 ALL OMISSIONS OR CONFLICTS BETWEEN THE VARIOUS ELEMENTS OF THE
WORKING DRAWINGS AND/OR SPECIFICATIONS SHALL BE BROUGHT TO THE
ATTENTION OF THE ARCHITECT AND THE STRUCTURAL ENGINEER BEFORE
PROCEEDING 'WITH ANY WORK INVOLVED.
4 CONTRACTOR TO PROVIDE ADEQUATE SHORING AND BRACING TO SUPPORT
ALL LOADS DURING CONSTRUCTION.
5 DURING CONSTRUCTION AND PRIOR TO THE INCORPORATION OFt ALL CHAN-
GESi REVISIONS! MODIFICATIONS AND/OR DEVIATIONS FROM THE STRUCTURAL
DRAWINGS SHALL BE BROUGHT TO THE ATTENTION OFi AND OBTAIN APPROVAL
FROM THE ARCHlTECTi STRUCTURAL ENGINEER AND THE GOVERNING BUILDING
DEPARTMENT.
LUMBER/FRAMING:
1 ALL 2X HORIZONTAL RF/CLG LUMBER TO BE MIN DF»2 U.N.O.
2 ALL 2X HORIZONTAL FLR LUMBER TO BE MIN DFM. U.N.O.
3 ALL 4X & LARGER HORIZONTAL LUMBER TO BE MIN DF #1 U.N.O.
A ALL GLULAMS TO BE DF/DF COMB 2AF-V4 DRY USE U.N.O.
5 ALL 2X VERTICAL LUMBER TO BE MIN DF #2 U.N.O.
6 ALL AX 2t LARGER VERTICAL LUMBER TO BE MIN DFttl U.N.O.
7 ALL PLYWD TO BE MIN CD-CC STRUCT II OR CDX.
8 TYPICAL NAILING SCHEDULE AS PER UBC 25-P.
9 BUILT-UP BEAMS: DBL 2*X MEMBRS TO BE FACE NAILED W/ MIN 16d 3
I2in OC STAGGERED TOP/BOT. 3 OR MORE 2X LAMINATIONS TO BE CONN
W/ l/2in DIA MB & WASHER MIN 3 2Ain OC STAGGERED TOP/BOT * 2 EA END,
10 CARRY .ALL POSTS & DBL STUDS DOWN TO FOUNDATIONS. BLOCK SOLID
AS RE'J'D FOR FULL BRG 3 FLR LINES.
»
CONCRETE:
1 PROVIDE MINIMUM BAR COVERAGE OF 3in FOR CONCRETE CAST AGAINST
EARTH.OR MINIMUM 2in FOR ALL FORMED CONCRETE.
2 CONCRETE AS PER ASTM C-150 (AGGREGATES PER ASTM C-33)t TYPICAL
PORTLAND CEMENT TYPE I. USE GRADE 'C' MIX 1:2-1/2:3-1/2 W/ MAX
7-1/2 GAL WATER PER SACK OF CEMENT.
M •* &«* SHEET NO TT--^ OF
5S!nS!!!S£l?'de COn5UltantS C«CUUTn- T44 .1941 Continental Lane
CA.9P02? """••"» •* DATE
(61 •) 746-51 1 2 8C.LE
CONCRETE:
jr
3 ALL CONCRETE TO REACH MIN ULT COMPRESS IVE STRESS OF 2500 PS I
3 2S DAYS U.N.O.
MASONRY: . •
1 CONCRETE MASONRY UNITS TO BE NORMAL WEIGHT HOLLOW LOAD BEARING
TYPE CONFORMING TO ASTM C-93. MASONRY UNITS SHALL BE CLEAN AND
FREE OF ALL SUBSTANCE THAT MIGHT IMPAIR BOND AND SHALL BE STORED
UNDER COVER ON THE JOB.
2 ALL CONCRETE MASONRY UNITS TO BE GRADE N-II U.N.O.
3 MIN COMPRESS1VE STRENGTH OF ALL MASONRY UNITS SHALL BE 1500 PSI.
4 TYPICAL TYPE 'M' MORTAR: 1 PART CEMENT. 3-1/2 PARTS SAND.
1/4 PART LIME PUTTY. CONFORM W/ ASTM C-270. WATER CONTENT
SHALL BE MIN RE(J'.'D FOR WORKING CONSISTENCY. MIN 2000 PSI.
5 GROUT MIX SHALL BE 1 PART CEMENT, 3 PARTS SAND AND (OPTIONAL)
1/10 PART LIME PUTTY. ADD UP TO 2 PARTS PEA GRAVEL WHERE SPACES
EXCEED 2in MIN. 28 DAY ULT STRENGTH OF GROUT SHALL BE 2000 PSI.
' USE SUFFICIENT WATER TO PRODUCE POURING CONSISTENCE W/0 SEGREGATION.
REINF STL:
1 ALL REINF STL TO BE MIN ASTM-A615 GRADE 40 U.N.O.
2 WELDED WIRE MESH: ASTM-A185; USE MIN 6X6-*10/S10 U.N.O.
LAP ALL MESH MIN 2 MODULES.
3 ALL REINF BARS SHALL BE ACCURATELY & SECURELY PLACED BEFORE
POURING CONC OR APPLYING MORTAR OR GROUT.
STRUCT STL:
1 ALL STEEL TO CONFORM TO ASTM-A36 U.N.O.
2 DETAILING & FABRICATION PER AISC - LATEST EDITION.
3 ALL STEEL PIPES TO CONFORM TO ASTM A53 GRADE B U.N.O.
*
FASTENERS:
1 ALL CONNECTORS NOTED TO BE SIMPSON OR EQUIVALENT.
2 ALL BOLTS TO BE MIN ASTM-A307.
3 BOLT HOLES: MAX l/16in LARGER'THAN BOLT DIA.
4 ALL BOLTS ERG ON WOOD TO USE M.I. WASHER UNDER HEAD & NUT.
5 LAG BOLTS: LEAD HOLES FOR SHANK TO BE SAME AS SHANK; THREADED
PORTION TO BE 60-707. OF SHANK DIA. .
6 ALL NAILS TO BE COMMON U.N.O.
TH&A
Engineering and Code Consultants
JQQ «ps^ i xfy f i i T^II^/JI f'V-Jii_V^_ vjiiflLJ-
1941 Contoental Lane CAICUL4T" 8Y— OATE
Eacondido, CA 9202? CHECKED BY D*TE
(619)746-5112 SCALE
FASTENERS:
7 USE FULL NAILING/BOLTING 3 ALL CONNECTORS U.N.O.
FOUNDATIONS:
1 PROVIDE MIN CODE REQUIREMENTS FOR ALL FOUNDATIONS U.N.O.
2 ALL CONT/ISOLATED FTG3 TO BE PLACED MIN I2in INTO COMPETENT
BRG SOIL OR BEDROCK.
3 ACQUISITION OF A SOILS REPORT IS RECOMMENDED FOR ALL JOBS.
IF NO SOILS REPORT IS AVAILABLE. ASSUM'D SOIL TYPE It BRG VALUE
USED IN CALCULATIONS ARE SUBJECT TO BUILDING DEPT APPROVAL.
ENGR WILL NOT BE HELD RESPONSIBLE FOR BLDG DEPT APPROVED VALUES.
4 SEE FOUNDATION PLAN FOR ALLOWABLE SOIL BRG PRESSURE.
RETAINING WALLS:
1 CONTRACTOR SHALL VERIFY ALL DIMENSIONS & CONDITIONS ON THE JOB.
2' RESPONSIBILITY FOR ACCURATELY DESCRIBING THE SITE CONDITIONS
RESTS ON THE CLIENT. REVIEW CALCULATIONS IMMEDIATELY TO DETERMINE
WHETHER CONSIDERATION WAS GIVEN IN WALL DESIGN FOR ADJACENT FTGt
VEHICLE OR BACKSLOPE SURCHARGES. CONTACT THIS OFFICE IMMEDIATELY
IF THERE IS ANY QUESTION REGARDING THIS MATTER.
3 IF NO SOILS REPORT IS AVAILABLEi ASSUM'D SOIL TYPE t BRG VALUE
USED IN CALCULATIONS ARE SUBJECT TO BUILDING DEPT APPROVAL.
4 VERIFY INSPECTION REQUIREMENTS W/ BLDG DEPT PRIOR TO CONSTR.
5 SEE RETAINING WALL SCHEDULE FOR BLOCK INSPECTION REQUIREMENTS.
6 ALL RETAINING WALL FTGS TO EXTEND MIN 12in INTO COMPETENT BRG
SOIL AS DEFINED BY SOILS REPORT OR APPROVED STANDARD PRACTICE.
RECOMMENDATIONS OF SOILS REPORT TO SUPERCEDE THIS MIN REQUIREMENT
7 BOTTOM OF PAD TO BE MIN 5' FROM DAYLIGHTi MEASURED IN A HORI2
DIRECTION FROM THE NEAREST BOTTOM EDGE OF PAD.
8 PROVIDE EITHER A MIN I2in x I2in GRAVEL POCKET 3 BASE OF WL
WITH 4in DIA PVC PERFORATED DRAIN PIPE TO DAYLIGHT* OR MIN 2 S<5IN WEE? HOLES 3 BASE OF WALL STEM TO ADJACENT GRADE 3 48in OC.9 BACKFILLING SHALL NOT BE STARTED FOR AT LEASTS! DAYS AFTER
THE FILLING OF THE CELLS WITH GROUT.10 DO NOT BACKFILL UNTIL ALL WORK HAS PASSED REfc'D INSPECTIONS.
BACKFILLING MUST BE THOROUGHLY TAMPED TO PREVENT FURTHER SETTLING.11 IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO PROVIDE ALL
SHORING DURING CONSTRUCTION AS REQ'D.
12 ALL BACKFILL MATERIALS TO BE GRANULARi i.a. SANDi GRAVELi OR
SOIL APPROVED BY PROJECT SOILS ENGINEER.
-CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 1 CF-1R
Project Title Gonzales Addition Date 09/26/94
--, Project Address 2728 Chestnut Avenue i
Carlsbad, Ca. 92008 _
Documentation Author... T.Q..Huynh Building Permit #
Company TH&A, Inc .
Telephone (619) 746-5112 Plan Check / Date
Compliance Method MICROPAS4 by Enercomp, Inc. Field Check/ Date
Climate Zone 07 '
MICROPAS4 v4.01 File-GONZALES Wth-CTZ07S92 Program-FORM CF-1R
User#-MP0820 User-TH&A, Inc. Run-New Master Bedroom
GENERAL INFORMATION
Conditioned Floor Area 297 sf
Building Type Single Family Detached
Construction Type Addition Alone
Building Front Orientation. Front Facing 180 deg (S)
Number of Dwelling Units... .23
Number of Stories 2
Floor Construction Type.... Raised Floor (Package E)
BUILDING SHELL INSULATION
Component Insulation Assembly
Type R-value U-Value Location/Comments
Wall
Roof
FloorExt
R-13
R-30
R-19
0.088 Exterior Wall
0.031 Ceiling
0.048 Floor
FENESTRATION
Orientation
Area U- # of Interior
(sf) Value Panes Shading
Exterior
Shading
Over-
hang/ Framing
Fins Type
Window Back (N)
Window Right (E)
Window Left (W)
40.0 0.870 2
8.0 0.870 2
15.0 0.870 2
Drapes.Std None
Drapes.Std None
Drapes.Std None
None Metal
None Metal
None Metal
Equipment Type
HVAC SYSTEMS
Minimum Duct
Efficiency Location
Duct Thermostat
R-value Type
Furnace
NoCooling
0.750 AFUE
10.00 SEER
Attic
Attic
R-2.1
R-2.1
Setback
Setback
SPECIAL FEATURES/REMARKS