Loading...
HomeMy WebLinkAbout2728 GROVE AVE; ; CB950637; Permit08/18/95 11:06 Page 1 of 1 B U I L D I N G Job Address: 2728 GROVE AV Permit Type: RESIDENTAL ADD/ALT Parcel No: 156-332-45-00 Valuation: 19,552 Construction Type: VN P E R M I T Suite : Lot#: Permit No : CB950637 Project No: A9500934 Development No: 3256 08/18/95 0001 01 C .. '. C-PRMT 278-1.11~ Occupancy Group: Reference#: Status: ISSUED Applied: 05/19/95 Apr/Issue: 08/18/95 Entered By: MOP Description: 208 SF ADDITION Appl/Ownr : WORTHING, BROOKS P.O. 1041 CARLSBAD, CA . 92018 *** Fees Required *** Fees: Adjustments: Total Fees: Fee description 619 729-3965 Fees Collected & Credits *** 'T'otal Credits : Total Payments : Balance Du e : Units Fee/Unit .00 135 .00 278 .00 Ext fee Data ---------------------------------------------------------------------------Building Permit Plan Check Strong Motion Fee * BUILDING TOTAL Enter "Y" for Plumbing Issue Fee > Gas Piping System > * PLUMBING TOTAL Enter "Y" for Electric Issue Fee > Enter "Y" for Remodel > * ELECTRICAL TOTAL Enter 'Y' for Mechanical Issue Fee > Each Install Fireplace ) * MECHANICAL TOTAL CITY OF CARLSBAD 207 .00 135 .00 2 .00 344.00 20.00 y 7.00 7.00 27.00 10.00 y 10.00 y 20.00 15.00 y 1 6.50 6 .50 22.00 FINAL APPROVAL I NSP. p <t DATE JI .J/p ff CLEAfl. ~1CE -----1 2075 Las Palmas Dr., Carlsbad, CA 92009 (6 19) 438-1 161 ~ (~{3 PERMIT APPLICATION PLAN CHECK NO. '( ~,.... G? ~ l City of Carlsbad Building Department 2075 Las PalllllS Dr., Carlsbad, CA 92009 (619) 438-1161 I. PFllMII fYP.E F.S'f. VAL I j '(' \ ""'2. ,-.. PLAN CK DEPOSIT c I 5 s -C:l VAIJD.BY. _____ --::,....t-,,,..-T'=-- From Llst I (see back) give code of Permit-Type: __ ...... R..;:..Lfo,_'P.;._ ____ _ DATE 1 /~ /1 For Residential Projects Only: From Llst 2 (see back) give Code of Structure-Type: ---~?~~,__Q""------------ Net Loss/Gain of Dwelling Units 2. PRCllECT INFORMATION Address Z,1.£> c'.:l'fl:lV'!-A,,e.. Buddmg or Su11e No. Nearest Cross Street ~ (A)~ LEGAL DESCRIPI ION • 2 Soils Report • l Addressed Envelope SQ. FT. # OF BEDROOMS 1 1 eren rom app 1can NAME (last name first) SAME ADDRESS 1963 05/19/95 0001 01 C-PRMT FOR OFFICE USE ONLY 0mt No. Phase No. # OF BATHROOMS CITY STATE ZIP CODE DAY TELEPHONE 4. APPLICArH tl'.CONJRACIOR DAGEN I FOR CONJRACIOR DOWNER DAGEN I FOR OWNER NAME (last name firstlWORTH ING, INC B. if'!lDRESS P. 0. BOX 1 0 4 1 CITY CARLSBAD STATE CA ZIPCODE 92018 DAYTELEPHONE (619) 729 3965 S. =~l'.Jt ':!'ell:}rst) LT 1 j rJ tha-f I J l-ee /.\r-Jµ ADDRESS '2..."] 2-8 C"croJ~ /1ve. 02 13.s:~oo CITY 0¥l~b.d.. STATE CA ZIP coDE"f-zaie, DAY TELEPHONE C/o 7 '2>f ;fFe5 •-~Plf.'ftl~me first) WORTHING, INC B. A. ADDRESS P. 0. BOX 1 041 f ...,'} 7 -Z. f -0 l f '( CITY CARLSBAD STATE CA ZIP CODE 9 2 0 1 8 DAY TELEPHONE ( 6 1 9 ) 7 2 9-3 9 6 5 STATE IJC. # 3 9 8 7 6 4 IJCENSE CLASS B 1 CITY BUSINESS IJC. # 5 4 9 2 0 0 DESIGNER NAME (last name llrst) WORTH G ADDRESS IN, B.A. P.O. BOX 104 1 CITY CARLSBAD STATE CA ZIP CODE 9 2 0 J 8 7. WukkERS' WMPRNSAIIDN DAY TELEPHONE 7 2 q 3 9 6 5STATE I.IC. #p 1 392891 Workers' Compensauon Declaration: I hereby afhrm that I have a cert1hcate of consent to self-msure issued by the Director of lndustnal Relations, or a certificate of Workers' Compensation Insurance by an admitted insurer, or an exact copy or duplicate thereof certified by the Director of the insurer thereof filed with the Building Inspection Department (Section 3800, Lab. C). SIGNATURE DATE 8. OWNmt-B0nnmt DFliXkA:IION • • • Uwner-BulJder Declaration: I hereby arhrm that I am exempt from the Contractors Llcense Law for the iollowmg reason: I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's Llcense Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale.). I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). I am exempt under Section _______ Business and Professions Code for this reason: (Sec. 7031.S Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's Llcense Law (Chapter 9, commencing with Section 7000 of Division 3 of the Business and Professions Code) or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars [$5001). SJGNA11JRE DATE COMPLEIE IHIS SECIION FOR NON-RESIDENIIAL BOlilliNG PERMIIS ONLY: Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? •YES •NO Is the applicant or future building occupant required to obtain a pennit from the air pollution control district or air quality management district? • YES • NO Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? • YES • NO IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCOJPANCY MAY NOT BE Jl?SllED AFTER JULY I, 1989 UNLESS THEAPPIJCANT HAS MET OR IS MEITING THE RF.QlllREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POILUTION CONTROL DISfRJCT. 9. WNSIROCIION LKNDING AGENCY I hereby afhrm that there is a construction lendmg agency for the perionnance of the work for which this penn1t 1s issued (Sec 3097(1) CIVIi Code}. LENDER'S NAME LENDER'S ADDRESS 10. APPUCANI CERIMCAIJUN I certify that I have read the apphcatmn and state that the above mformatton 1s correct. I agree to comply with all City ordmances and State laws relating to building construction. I hereby authorize representatives of the City of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE m SAVE INDEMNIFY AND Kl!EP HARMIBSS THE CJ1Y OF CAlllSllAD AGAINST AU. IJABILITIES, JUDGMENTS, (DSTS AND EXPENSES WHICH MAY IN ANY WAY ACDUJE AGAINST SAID CJ1Y IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: An OSHA pennit is required for excavations over 5'0" deep and demolition or construction of structures over 3 stories in height. PERMIT# CB950637 DESCRIPTION: 208 SF ADDITION TYPE: RAD JOB ADDRESS: 2728 GROVE AV APPLICANT: WORTHING, BROOKS CONTRACTOR: OWNER: CITY OF CARLSBAD INSPECTION REQUEST FOR 11/16/95 PHONE: PHONE: PHONE: INSPECTOR AREA TP PLANCK# CB950637 OCC GRP CONSTR, TYPE VN STE: LOT: 619 729-3965 REMARKS: MW/GAIL/729-3965 SPECIAL INSTRUCT: INSPECTOR _J>.,.,__~( ________ _ TOTAL TIME: LVL DESCRIPTION ACT COMMENTS CD 19 29 39 49 ST Final structural PL Final Plumbing EL Final Electrical ME Final Mechanical ~,' 3° [o N Q. ~ ~ <; 17) o ~ ',b ~~(__Tu ,e_ S -3/ ,,•Lf~ # ------------ ;;/ ,..,<1> DJ5rJi= --------------------------------------------------------- ***** INSPECTION HISTORY***** DATE 111495 102095 101795 101795 101795 101195 101195 101195 101195 100695 100695 100695 100395 091895 DESCRIPTION Final Combo Exterior Lath/Drywall Frame/Steel/Bolting/Welding Insulation Gas/Test/Repairs Frame/Steel/Bolting/Welding Rough Electric Gas/Test/Repairs Rough/Ducts/Dampers Frame/Steel/Bolting/Welding Rough Electric Rough/Ducts/Dampers Roof/Reroof Ftg/Foundation/Piers ACT INSP CA DC AP DC CO TP AP TP CO TP AP TP AP TP CO TP AP TP CO PK CO PK CO PK AP TP AP TP COMMENTS PER CONTRACTOR/PHONE SEE JOB CARD (CORR NOT COMP) LINE COVERED FOR RE-INSP REV/STRAP OUTR PLATES@ BEAM SEE CARD DUCT EXT SEE NOTICE SEE CARD NOTE \ ,', ",;< ~~~ nl&A; eoe1 En1ineerin1 and Code Consultants 2581 Vista La10 Terrace Escondido, California 92029 (619) 746-5112 7112-- ?TAAP flODUCt~1 tSlliiJleSIINs)2'»-1 tl'IIIIINl /,,..,_/.IIN: .. ~.lilm 01411. Tg(lr#PID( TlN.LFREE 1·1Q-?'lS-6380 SHEETNQ. _______ Of' _____ _ CALCULATEDBV ______ DATE ____ _ CHECKEOBY _______ DATE ____ _ SCALE . ' • • ·• .. > ·•• L . ' '\: ! ., . \ ' ~A-12-pi~ I . · ..... · ______,. •. . ... r·· . "\.AN4-loft,. i,o1,:( . · ·· · PLAN CHECK N0:_'1~&_·0~S_{~--- JURISDICTION: __ ~C=I=TY~-9=F~CARL=~S=B=AD~- TO: _________________ _ ENCLOSURES: ___________ _ PROJECT ADDRESS :_2,"""-'lc..:'-:::.8=.._l""':;'-'f'-"0'-'0-''<,.=--/,'-_)-'-j_Q.. FLOOR AREA:_l..-=-_o---'8,,..__&;JZfc..._ ___ _ STORIES: _____________ _ HEIGHT:_~-------------- REMARICS : r A.~\ i PLAN CORRECTION SHEET CITY OF CARLSBAD SINGLE FAMILY AND DUPLEX DWELLINGS Date plans received by jurisdiction: Date plans received by Esgil Corporation: Date initial plan check completed: __________ .By: _______ _ FOREWORD: PLEASE RBAD Plan check is limited to technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the handicapped. The plan check is based on regulations enforced by the Building Inspection Department. You may have other corrections based on laws and ordinances by the Planning Department, Engineering Department or other departments. Present California law mandates that residential construction comply with Title 24 and the following model codes: 1991 1991 1990 1991 UBC UPC NEC UMC (eff .. 8/14/92) (eff. 8/14/92) (eff. 7/1/91) (eff. 8/14/92) The above regulations apply to residential construction, regardless of the code editions adopted by ordinance. The circled items listed need clarification, modification or change. All items have to be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 303(c), 1991 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. Tq speed up the recheck process, note on this list <or a copy) where each correction item has been addressed i.e .• plan sheet, specification, etc. Be sure to enclose the marked UP list when you submit the revised plans. Applicant contact person: "'"f>""'·_;W=o<..:.r-_:\-A,___i,,_)-1----Telephone ,l 2 er . 3'1 ~s- NOTE: PAGE NUMBERS llZ NOT IN SEQUENCE AS PAGES llAVINO NO ITEMS NEED.nm CORUCTIONS WEU DELETED, List No. 2, Carlsbad Single Family Dwelling and Duplex With All Supplements. (1991 UBC) PLANS 1. Please make all corrections on the original tracings and submit two new sets of prints, to: Esgil Corporation, 9320 Chesapeake Drive, Suite #208, San Diego, California 92123, (619) 560-1468. 2. Please make all corrections on the original tracings and submit two new sets of prints, to: The jurisdiction's building department. 3 . Indicate on the Tit le Sheet of the plans the name of the legal owner and name of the person responsible for the preparation of the plans. Section 302(a)7. 4. All sheets of plans must be signed by the person responsible for their preparation. (California Business and Professions Code). 5. Plans, specifications and calculations shall be signed and sealed by the California state licensed engineer or architect responsible for their preparation, for plans deviating from conventional wood frame construction. Specify expiration date of license. (California Business and Professions Code). 6. Specify on the Title Sheet of the plans the gross floor area of each element of this project, including dwelling, garage, carport, patio, deck and balcony. Section 302(d). ~ Provide a statement on the Title Sheet V of the plans that this project shall comply with Title 24 and the 1991 UBC, tJMC and UPC and 1990 NEC. 11/18/93 8. Submit fully dimensioned plot plan, drawn to scale, showing location, size, and uses of all existing and proposed structures on the lot. Identify property lines and show lot dimensions and all easements. Section 302 (dl. 9. Indicate distance from property lines to the proposed building. Section 302 (d) . 10. On the cover sheet of the plans, specify any items requiring special inspection, in a format similar to that shown below. Section 302(c). REQUIRED SPECIAL INSPECTIONS In addition to the regular inspections, the following checked items will also require Special Inspection in accordance with Sec. 306 of the Uniform Building Code. ITEM REQ. IF CHECKED SOILS COMPLIANCE PRIOR TO FOUNDATION INSP. STRUCTURAL CONCRETE OVER 2500 PSI PRESTRESSED STEEL FIELD WELDING HIGH STRENGTH BOLTS EXPANSION ANCHORS SPECIAL MASONRY SPRAYED-ON FIRE PROOFING PILES/CAISSNS DESIGNER-SPECIFIED OTHER 2 11. Show on the title sheet all structures, pools, walls, etc. included under this application. Any portion of the project shown on the site plan that is not included with the building permit application filed should be clearly identified as "not included." 12. Clearly show if the lower level is a basement or a story, based on the definitions in Sections 403 and 420. Plot the finish grade (as defined) on the elevations and dimension the distance to the floor above, for story determination. 13. 14. 15. 16. 17. 18. !'IRE PROTECTION Exterior walls closer than property lines shall be rated construction and openings. Table 5-A. 3 feet to one-hour have no Exterior walls closer than 3 feet to a property line shall have 30 inch parapets when the floor area per floor exceeds 1,000 square feet. See Section 1710 for possible exception. Projections, including eaves, may not extend more than 12 inches into the 3 foot setback from the property line. Section 504(b). · Eaves over required windows shall be not less than 30 inches from the side and rear property lines. Section 504(a). Projections, including eaves, shall be one-hour fire-resistive construction, heavy timber or of noncombustible material if they project into the 3 • setback area from the property line. Section 1711. Plastic skylights shall not be installed within that portion of a roof located within a distance to property line where openings in exterior walls are prohibited or required to be protected. Section 5207 (a) 7. 19. Show locations of permanently wired smoke detectors with battery backup: 11/16/93 21. 22. 23. 24. a. Inside each bedroom. b. Centrally located in corridor or area giving access to sleeping rooms. c. On each story. d. In the basement, if part of the dwelling unit. e. When sleeping rooms are upstairs, at the upper level in close proximity to the stair. f. In rooms adjacent to hallways serving bedrooms, when such rooms have a ceiling height 24 inches or more above the ceiling height in the hallway. NOTE: Detectors shall sound an alarm audible in ,all sleeping areas of the unit. Section 1210 When the valuation of a room addition or repair exceeds $1,000, or when sleeping rooms are created, smoke detectors shall be provided per item 19 above. except that smoke detectors added at existing construction need only be battery powered. Section 1210. GBNBRAL RESIDENTIAL REOUIREMBNTS Habitable rooms, other than kitchens, shall contain at least 70 square feet of floor area: At least one room shall have not less than 120 square feet of floor area. Section 1207 (bl. No habitable room, other than a kitchen, shall be less than 7'0" in any dimension. Section 1207 (c). Sleeping rooms shall have a window or exterior door for emergency exit. Sill height shall not exceed 44" above the floor. The window must have an openable area of at least 5. 7 square feet with the minimum openable width 20" and the minimum openable height 24". Section 1204. Basements in dwelling units shall comly with the above (even if not designated as sleeping rooms). Section 1204. 3 b. At all interconnections between concealed vertical and horizontal spaces such as occur at soffits, drop ceilings and cove ceilings; c. In concealed spaces between stair stringers at the top and bottom of the run and between studs along and inline with the run of stairs if the walls under the stairs are unfinished; d. In openings around vents, pipes, ducts, chimneys, fireplaces and similar openings which afford a passage for fire at ceiling and floor levels, with noncombustible materials. e. At openings between attic spaces and chimney chases for factory-built chimneys. 108. In duplexes, draft stops shall be provided in floor-ceiling assemblies and attics in line with walls separating units and separating units from common areas. Section 2516(f)4. 109. Show stud size and spacing. Maximum allowable stud heights: Bearing wall: 2 x4 and 2 X 6 max. 10' ; Non-bearing: 2 X 4 max. 14' , 2 X 6 max. 20'. Table 25-R-3. 110. Studs supporting two floors, a roof and ceiling must be 3 x 4 or 2 x 6 at 16" o.c. Table 25-R-3. 111. Note on the plans that an A.I.T.C. Certificate of Compliance for glued laminated wood members shall be given to the building inspector prior to installation. Section 2505. 112. Detail all post-to-beam and to-footing connections reference the detail to the section 2516 (m). post- and plan. 113. Detail shear transfer connections, including roof and floor diaphragms, to shear walls. Section 2513. l,J 11/17/93 114. Specify nail size and spacing for all shear walls, floor and roof diaphragms. Indicate required blocking. Maintain maximum diaphragm dimension ratios. [Tables 25 I, J, Kand Section 4714 (d) l . 115. Provide truss details and truss calculations for this project. Specify truss identification numbers on the plans. 116. Show clearance between top plate of interior partitions and bottom chord of trusses. (To ensure non- bearing condition between supports as designed). 117. Provide roof framing plan and floor framing plan. Section 302 (d). 118. Provide framing sections through Section 302 (d) . 119. Specify all openings over 2517 (g) 5. header sizes for 4' wide. Section 120. Provide calculations for main vertical and horizontal framing members and footings. Section 302 (b) • 121. Provide calculations for lateral loads, shear panels, shear transfer and related. Section 302 (b). 122. In Seismic Zones 3 and 4, the allowable shear wall values for drywall in Table 47-I must be reduced 50 percent when considering earthquake loads. This does not apply to wind loads. Footnote 1. 123. Show on the plans all structural requirements developed in the structural calculations. Sect ion 302 (d). (See comments below or at end.) 9 The City of Carlsbad has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 619/560-1468, to perform the plan check for your project. If you have any questions regarding these plan check items, please contact at Esgil Corporation. Thank you. 11/19/93 14 City of Carlsbad M ¥i ,,. i iet441iei• 1 ·24 ·El;;, ,i§ ,\I _d ! BUILDING PLANCHECK CHECKLIST DATE: ~1 Lq 'S: PLANCHECK NO. CB 9 .< cl t 3 7 BUILDING ADDRESS : a:71,r 6 ,,ec; ii e /}e,1E I PROJECT DESCRIPTION: -,,&,.s ~pt?rd, A-I /Jp/J{n'D~ ~r J:;4 /56 -3 i'l:: -'f.S-Ci 71-o<. H-.3 ASSESSOR's PARCEL NUMBER: __________ EST. VALUE /~J.33., L..~rqs- ENGINEERING DEPARTMENT t:: DENIAL APPROVAL PINN ... the lltached report cA deftcienciea marked / The Item you have submitted f0t review hu bNn with ~ Make nec:1111,y COffec:tlona to plans or 1~~ I apPfoved. The approval Is based on planl, lnfonnatlon apecificallona ,o, com~ with applicable codee and Ii ? and/or specificatiOns P'OYided In your submittal; tnerlfort standardl. Subm• cooected pilnl and/or specifications any changes to these ltlffll after thil dale, Including field to this office fo, review. ,/ 11 ~ 'CD /J 11 /~ modiflc:allona, must be revt.wed by thil office to inaufe ~/£2:;'?> ~ ~ /1 A e-,,t,1 /J ~ ~; I ' continued confonnance with applicable codN. PINN /"'' review caratulty all commenta lltached, a failure to // / / / .~. /_ comply with lnstructlOnl In this report can result In By~·--------~-..................... -----Date:~ suspension cA permit to build. • By: ~ A Right-a-Way permit la required prior to c:onstructlOn ------------- cA the following lmprovementa: ATTACHMENTS D Oedlcadon Applelllon • Oedlcltion a... 0 lmP'ovement Applelllon • lmplovemenl Checklllt • Future lmp(OYement AgrNmenl • Grading Perm• Appllcllion • Grading Submittal Checkllll • Right cA Way Penni Appliclli0n . • Right cA Way Permit Submittal Checklist and lnf0rmadon ShNI • Sewer FN lnfonnldon Sl"INI By: ________ Date: ___ _ NAME: ____________ _ Cltyc:AClnlbacl ADDRESS: 2075 La Patmp Or., cartsbld. CA 92009 PHONE : {§19) 438-1161, Ext. A• P:\DOCS\CHKLS1'\8P0001.nlll RIV Ol/11/M 2075 Las Palmas Dr.• Car1sbad, CA 92009-1576 • (619) 438-1161 • FAX (619) 438-0894 ' 1 st~✓ 3rd✓ @ •-• • I • • • BUILDING PLANCHECK CHECKLIST SITE PLAN 1. lovide a fully dimensioned site plan drawn to scale. Show: 'A. North Arrow D. Property Unes Easements /e. Existing & Proposed Structures E. Easements C. Existing StrHt Improvements F. Right-of-Way Width & Adjacent Streets 2. Show on site plan: A. Drainage Patterns C. Existing Topography B. Existing & Proposed Slopes 3. Include note: 'Surface water to be directed away from the building foundation at a 2% gradient for no less than 5' or 2/3 the distance to the property line (whichever Is less).' [Per 1985 UBC 2907(d)5]. On graded sites, the top of any exterior foundation shall extend above the elevation of the street gutter at point of discharge or the Inlet of an approved drainage device a minimum of 12 Inches plus two percent' (per 1990 UBC 2907(d)5.). 4. Include on title sheet A. Site address B. Assessor's Parcel Number C. Legal Description For commerclalllndustrlal buildings and tenant Improvement projects, Include: Total building square footage with the square footage for each different use, existing sewer permits showing square footage of different uses (manufacturing, warehouse, office, etc.) previously approved. EXISTING PERMrT NUMBER DESCRIPTION Page 1 af 4 MYOl(l1/M f BUILDING PLANCHECK CHECKLIST DISCRETIONARY APPROVAL COMPLIANCE ~t✓ 2 d✓ E)d✓ S. Profec:t d0e1 not comply with the following EnginHring Conditions of approval for Project No. fv J> An E;):t1 C> M f::" r,1-r Conditions were complied with by: otr,~Date: 1/21 Ir( r, DEDICATION REQUIREMENTS D D O 6. Dedication for all strut Rights-of-Way adjacent to the building site and any storm drain or utility easements on the building site is required for all new buildings and for remodels with a value at or exceeding $. _____ -pursuant to Code Section 18.40.030. Dedication required as follows: _______________ _ Attached please find an application form and submittal checklist for the dedication process. Provide the completed application form and the requirements on the checklist at the time of resubmittal. Dedication completed by ___________ _ Date: ___ _ IMPROVEMENT REQUIREMENTS D O O 7a. All needed public Improvements upon and adjacent to the building site must be constructed at time of building construction whenever the value of the construction exceeds ..._ _______ -pursuant to Code Section 18.40.040. Public Improvements required as follows: ____________ _ PINN have a reglltered CMI EnglnNr prepare appropriate improvement plans and submll them together with the requirements on the attached checklist for a separate plancheclc Pf0CN1 through the EnginHring Department. Improvement plans must be apprcN9d, appropriate MCUrities poated and fees paid prior to isluance of permit. Attached pie... find an application form and submittal checklist for the public improvements requirements. Provide the completed application form and the requirements on the checklist at the time of resubmittal. Improvement Plans signed by: __________ Date: __ _ Plgl 2 of 4 MVOll11/M l BUILDING PLANCHECK CHECKLIST Connuellon of the public improvements may be deferred pursuant to code Section 18.40. Pleue submit a recent property title report or current grant deed on the property and processing fee of $, ________ so we may prepare the neceuary Future Improvement Agreement. Thia agrffment must be signed, notarized and approved by the City prior to Issuance of a Building Permit. Future public improvements required u follows: ___________ _ Improvement Plans signed by: __________ _ Date: ___ _ D D D 7c. Enclosed please find your Future Improvement Agrffment. Please return signed and notarized Agrnment to the Enginffring Department. • Future Improvement Agreement completed by: ___________ _ Date: _______ _ 7d. No Public Improvements required. SPECIAL NOTE; Damaged or defectlye improvements found adjacent to building site must bt repaired to me satisfaction of tht Cttv inspector Prior to occupancy, GRADING PERMIT REQUIREMENTS The conditions that invoke the need for a grading permit are found in Section 11.06.030 of the Municipal Code. D D D ea. Inadequate information available on Sita Plan to make a determination on grading requirements. Include accurate grading quantities (cut, flU import, export). D D D 8b. Grading Permit required. A separate grading plan prepared by a registered Civil Engineer must be Submitted together with the completed application form attached. NOTE; The Grading ptrmlt must be issued and rough grading approval obtained prior to ISSUIQCI of I BuHding permit. G11d11g lnlpector sign off by: ________ Date: ___ _ • 8c. No Grading Permit required. Page 3 cf 4 MV01111/M l BUILDING PLANCHECK CHECKLIST MISC:':! I ANEOUS PERMITS ).1✓ 2nd✓ 3rd✓ 17> • • 9. A BIGHT-Of-WAY PERMIT is required to do work in City Right-of-Way and/or private work adjacent to the public Right-of-Way. Types of work Include, but are not limited to: street improvements, trees, driveways, tieing into public storm drain, sewer and water utilities. Right-of-Way permit required for _______________ _ A separate Right-of-Way permit issued by the Engineering Department is required for the following: _____________________ _ 1 O. A SEWER PERMIT is required concurrent with the building permit Issuance. The fee is noted in the fees section on the following page. 11. INPUSIBIAL WASTE PERMIT is required. Applicant must complete Industrial Waste Permit Application Form and submit for City approval prior to issuance of a Permit. Industrial waste permit accepted by:_______ Date: ___ _ Page 4 al 4 IIEYOlll1/t4 '~ " ~ \J ,l n l\ ~ • • • • Q Q ~Iii l l ; "' • ... ... " ! • " " i i .. .: • -• • l ; ... ! i .: PLANNING OiECJCUSI' Plan Check No. 95-637 Address 2 72/3 u/2cJ/JE A//1:f Planner VAN LYNCH (Name) APN: /-½ -S 32 -</.> Phone 438-1161 ext . ....;.:llla.;:;2.;.5 ---- Type of Project and Use /2-EE1t:;,&,.17TAL... ,1J '!::,z:, /_77d~ Zone P C Facilities Management Zone _ __,, __ _ CFO (i~ # our. ~ (If property in, complete SPECIAL TAX CALCULATION WORKSHEET provided by Building Department.) Item Complete Item Incomplete • Needs your action 1, 2, 3 Number in circle indicates plancheck number where deficiency was identified ✓□ 0 Enviroammtal Rmew Required: YES _ NO ~ 'TYPE __ _ DATE OF COMPLETION: ____________________ _ Compliance with conditions of approval? If not, state conditions which require action. Conditions of Approval ____________________ _ APPROVAL/R£SO. NO. ___ DATE: 7---71-?C: PROJECT NO. Pl-/ i> 6'@ OTHER RELATED CASES: _..,_A..:;;-U;;....:.D___._8.....,,_/__._A;;;.u,..b:.......6'-'(6..,.~.,;---------- Compliance with condidom of approval? If not, state conditions which require action. Conditions of Approval ____________________ _ California Coata1 O+oo "rim l'mnit Required: YES _ NO ~ DATE OF APPROVAL: ____________________ _ San Diego Coast District, 3111 Camino Del Rio North, Suite 200, San Diego, CA. 92108-1725 (619) 521-8036 Compliance with conditions of approval? If not, state conditions which require action. Conditions of Approval ____________________ _ arD O llldusioaary Housing Fee required: YES _ NO L (Effective date of Cnclusiona,y Housing Ordinance -May 21, 1993.) Site Plan: 1. 2. Zoning: ••• 1. • D • t.J(A 2. rn1J O /1.J O CH// N 1,8' 3. IY1J • 4. Provide a fully dimensioned site plan drawn to scale. Show: North arrow, property lines, easemenu, existing and proposed structures, stteeu, existing street improvemenu, right-of-way width, dimensioned setbacks and existing topographical lines. Provide lepl description of property, and assessor's parcel number. Setbacks: Front: AJO dfll wug-Required Shown [nt. Side: Required J Shown F'6" Street Side: Required --shown - Rear: Required 10 Shown ,o' ?" Lot coverage: tz.i,~r.eRequired Shown IN CtJtl~r,g- Height: Required Shown Parkins: Spaces Required z_ Shown 2-- Guest Spaces Required Shown Additional Commenu A P1.1 b /+141 BN"l> vw /:;/Wt Is P1?MAl-, -, ?-)l-f?'C A;)~&ltff) OK TO [SSUE AND ENTERED APPROVAL [NTQ COMPUTER. /J. ~ L .... ··-· --·.