HomeMy WebLinkAbout2728 LOKER AVE W; ; CB002486; PermitCity of Carlsbad 08/07/2000 1635 Faraday Av Carlsbad, CA 92008 Commercial/Industrial Permit Permit No: CB002486 Job Address: Permit Type: Parcel No: Valuation: Occupancy Group: Project Title: Applicant: AVENT LISA Building Inspection Request Line (760) 602-2725 2728 LOKER AV WEST CBAD Tl Sub Type: 2090812900 Lot#: $1,064,000.00 Construction Type: 28 Reference #: ABTECH SYSTEMS COMM 0 NEW Tl -OFFICE 31000 SF & WHSE 7000 SF Owner: Status: Applied: Entered By: Plan Approved: Issued: Inspect Area: CARLSBAD CROSSROADS LTD 1413 LLOYD PLACE ESCONDIDO CA 92027 760-740-0133 5666 LA JOLLA BLVD #139 LA JOLLA CA 92037 PENDING 07/03/2000 JM Total Fees: $38,129.35 Total Payments To Date: $2,885.25 Balance Due: $35,244.10 Building Permit Add'I Building Permit Fee Plan Check Add'I Plan Check Fee Plan Check Discount Strong Motion Fee Park Fee LFM Fee Bridge Fee STD #2 Fee STD #3 Fee Renewal Fee Add'I Renewal Fee Other Building Fee Pot. Water Con. Fee Meter Size Add'I Pot. Water Con. Fee Reel. Water Con. Fee Inspector: $3,632.10 $0.00 $2,360.87 $0.00 $0.00 $223.44 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 Meter Size Add'I Reel. Water Con. Fee Meter Fee SDCWAFee CFO Payoff Fee PFF PFF" (CFO Fund) License Tax License Tax (CFO Fund) Traffic Impact Fee Traffic Impact (CFO Fund) LFMZ Transportation Fee PLUMBING TOTAL ELECTRICAL TOTAL MECHANICAL TOTAL Master Drainage Fee: Sewer Fee: Redev Parking Fee: TOTAL PERMIT FEES FINAL APPROVAL Date: /IYr ?7J1 -t:?'e) Clearance: $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $10,695.00 $0.00 $0.00 $111.00 $160.00 $42.00 $0.00 $20,904.94 $0.00 $38,129.35 NOTICE: Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as 'fees/exactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capactiy changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project NOR DOES IT APPLY to any fees/exactions of which vou have oreviouslv been aiven a NOTICE similar to this, or as to which the statute of limitations has oreviouslv otherwise exoired. City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 08/23/2000 Commercial/Industrial Permit Permit No: CB002486 Building Inspection Request Line (760) 602-2725 Job Address: 2728 LOKER AV WEST CBAD Permit Type: Tl Sub Type: Parcel No: 2090812900 Lot#: Valuation: $355,844.00 Construction Type: Occupancy Group: 28 Reference #: Project Title: · ABTECH SYSTEMS Tl -RECONFIGURE EXIST BUILDOUT COMM 0 NEW Status: Applied: Entered By: Plan Approved: Issued: ISSUED 07/03/2000 JM 08/22/2000 08/23/2000 Applicant: Owner: Inspect Area;.,,. ~n , . ..,..., ,,." flf"' 1 • 6l .\'.'..J \}01 ~ ... ;; UV V-..1\}~ 0.1. AVENT LISA 1413 LLOYD PLACE ESCONDIDO CA 92027 760-740-0133 Total Fees: $4,245.61 Building Permit Add'I Building Permit Fee Plan Check Add'I Plan Check Fee Plan Check Discount Strong Motion Fee Park Fee LFM Fee Bridge Fee BTD #2 Fee BTD #3 Fee Renewal Fee Add'I Renewal Fee Other Building Fee Pot. Water Con. Fee Meter Size Add'I Pot. Water Con. Fee Reel. Water Con. Fee Inspector: CARLSBAD CROSSROADS LTD 5666 LA JOLLA BLVD #139 LA JOLLA CA 92037 C-PRHT Total Payments To Date: $2,885.25 Balance Due: $1,360.36 $1,517.08 Meter Size $0.00 Add'I Reel. Water Con. Fee $0.00 $986.10 Meter Fee $0.00 $0.00 SDCWAFee $0.00 $0.00 CFO Payoff Fee $0.00 $74.73 PFF $0.00 $0.00 PFF (CFO Fund) $0.00 $0.00 License Tax $0.00 $0.00 License Tax (CFO Fund) $0.00 $0.00 Traffic Impact Fee $438.38 $0.00 Traffic Impact (CFO Fund) $0.00 $0.00 LFMZ Transportation Fee $0.00 $0.00 PLUMBING TOTAL $111.00 $0.00 ELECTRICAL TOTAL $160.00 $0.00 MECHANICAL TOTAL $42.00 Master Drainage Fee: $0.00 $0.00 Sewer Fee: $916.32 $0.00 Redev Parking Fee: $0.00 TOTAL PERMIT FEES $4,245.61 FINAL APPROVAL Date: Clearance: _____ _ NOTICE: Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capactiy changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project NOR DOES IT APPLY to any fees/exactions of which vou have oreviouslv been aiven a NOTICE similar to this, or as to which the statute of limitations has oreviouslv otherwise exoired. 02 ~qcf( PERMIT APPLICATION CITY OF CARLSBAD BUILDING DEPARTMENT 1635 Faraday Ave., Carlsbad, CA 92008 A~ssor's Parcel # Existing e - 1<,£--LJ,J Fl 6UAA---T71JJ,/ () FEX1.5T//V6 8th L/) (J/) I ,,...--: ----# of Bathrooms Description of Work ~ SO. FT. , ,"i-7 #of Stories b # of Bedrooms 1-·-"'-----.---.. ,°3?lPO/)_ .. t>.£~-___ .74':'.'t> ¥-'-tvA,e ?ltJl/5€.. __ _ ,g;,,,, ·Q,QN;T~qrpJ;R$u~;'.1t-411f~t, qrQz.rl1i;81J~lc:·· ,-' ,, ' , Pt csc.o ·d,dti 'A-' ~ ~t)..:.· -tJ/33 Name Addres City State/Zip Telephone# Fax# i3vf ~~1-A=~~ri~-E-~9#g[fj"lfr;!Jo;7~J0:1/i ~ot~gr:'iiil P1;~~~'cff9[;2~ ~1'~~1i~b Name Address City State/Zip Telephone # 'ria:PL5~i,iti> -. ~C;O.SSRoir/Js ib' .. :si,(i?~c:. ~-$//(i ·g;. iim /4 :Ji;/4 .C,4 92ZJ 37 t~~~;ONTRAc:foR,;cc>'l\fANY,NAME'·::·:':;~~~~~----, .. --:-··--a .,_,, --_---,_,,. .. _ · · · Ci~V. .. , ... :--': ... --· s.t_a_t_el~i~ ,, .. ---_T_:,,le~~5$~(/_5-,,$~/ 11(} "" ",,,,,,, ' , , " , p '"". ' , ' ,,, . , " ' "' , "' ,,, ' {Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law [Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code] or that he is exempt therefrom, and the basis for the alleged exention. ,Ar);f violation of Section 7031.5 by any applicant !oya permit subjects the applicant to a civil penalty of not more than five hundred dollars [$500]). D£/IK I /f/6 C,tM/5 n? UC-77 tJ N Name Address City State/Zip Telephone# State License # ----------License Class _________ _ City Business License # _______ _ Designer Name · Address City State/Zip Telephone State License # _________ _ ~-~~: ' WOl:l,&El\,S,~ QOMPE~,$ATJC;>I'~,,', < , , v, ~_,,; W.f '-,-,v '< ,"'"'-,: ", _,,,.' ,-:: "~,. ,,,,"',_ ¥~,_-' :M Workers' Compensation Declaration: I hereby affirm under penalty of perjury one of the following declarations: 0 I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 0 I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My worker's compensation insurance carrier and policy number are: Insurance Company____________________ Policy No .. ____________ Expiration Date _______ _ {THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS ($100] OR LESS) 0 CERTIFICATE OF EXEMPTION: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. WARNING: Failure to secure workers' compensation coverage is unlawful, and shall subject an employer .to criminal penalties and civil fines up to' one hundred thousand dollars ($100,000), in addition to the cost of compensation, damages as provided for in Section 3706 of the Labor code, interest and attorney's fees. SIGNATURE _____________________________ DATE ________ _ 11~.:-.ow~~fl-.!!!.l!~l;ig_Q Pl:QLA.ilA1!QN .. -. -. . . -·-, -.,. --- I hereby affirm that I am exempt from the Contractor's License Law for the following reason: D I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale {Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). )sz1_ I, as owner of the property, am exclusively contracting with licensed contractors to construct the project {Sec. 7044, Business and Professions Code: The ~ntractor' s License Law does not l!PPIY to an owner of property who builds or improves thereon, and contracts for such projects with contractor{s) licensed pursuant to the Contractor's License Law). 0 I am exempt under Section ______ Business and Professions Code for this reason: 1. I personally plan to provide the major labor and materials for construction of the proposed property improvement. D YES ONO 2. I {have / have not) signed an application for a building permit for the proposed work. 3. I have contracted _with the following person {firm) to provide the proposed construction {include name / address / phone number / contractors license number): 4. I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work {include name / address / phone number/ contractors license number): __ --, ___________ ...,,.'-1------------------------------- 5. I will provide some of the work, but I persons to provide the work indicated {include name / address / phone number / type of work): _________ r-::;,o"ir",f--------,,-=,.,._.:7"',;;::=----------------:=-.f----,f-------------- Is the applicant or future building occupa equired to submit a business plan, acutely hazardous materials registration ~r risk management and prevention program under Sections 25505, 25533 or 5534 of the Presley-Tanner Hazardous Substance Account Act? 0 YES ~ NO Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? 0 YES ~O Is the facility to be constructed within 1,000 feet of the outer boundary of a school sit?? 0 YES ~ IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. f~• ... CQN$JRt.f~1'.IQ.l'HJ;NP,l11iG A.G~NCY .... ,:·. _ .. : # ·_ ~ .... -. ' •• -•• ,, _ • .,, , , , I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097(i) Civil Code). LENDER'S NAME ___________ ::.::,:;.-::-:;:.~----~-~~_:~~ ADDRESS ________________________ _ ~.. ~l'f!.tG~J\!J,GEQTlflCA:flO~' ·. : --·-· ........ -·-·c ·• ••• · -.. --, · • • • ... • I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all City ordinances and State laws relating to building construction. I hereby authorize representatives of the Citt of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: An OSHA permit is required for excavations over 5'0" deep and demolition or construction of structures over 3 stories in height. EXPIRATION: Every permit issued by t e building Official under the p · ions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is not com e ced within 180 days from th at of such permit or if the building or work authorized by such ermit is suspended or abandoned at any time after the work is com n d for a period of 180 · n 106.4.4 Uniform Building Code). APPLICANT'S SIGNATURE -1---,µ~=;qq:.,,,:;.,~::L.<l!=;..,::,-~-------------DATE -~~==-c~:::..,,~------ YELLOW: Applicant PINK: Finance City of Carlsbad Bldg Inspection Request For: 10/19/2000 Permit# CB002486 Inspector Assignment: RB --- Title: ABTECH SYSTEMS Description: Tl -RECONFIGURE EXIST BUILDOUT Type: Tl Sub Type: COMM Phone: 7604974559 Job Address: 2728 LOKER AV WEST Suite: Lot 0 Location: APPLICANT AVENT LISA ROSSROADS LTD Total Time: Inspector:~ Requested By: DAVID ERB Entered By: CHRISTING CD Description Act Comments 19 Final Structural & ______ _ 29 Final Plumbing 39 Final Electrical 49 Final Mechanical Associated PCRs lnsQection Histo!Y Date Description Act lnsp Comments 10/13/2000 84 Rough Combo AP RB ONTBARCOS 10/13/2000 89 Final Combo PA RB TEMP C OF O GRANTED -SEE ATTACHED LIST 10/11/2000 89 Final Combo NR RB STILL NEED TO VACATE BLDG FOR FINAL INSP. 10/10/2000 84 Rough Combo co RB STILL MISSING CO ONT-BAR INSP 10/10/2000 89 Final Combo co RB BLDG OCCUPIED W/OUT FINAL INSP. 10/4/2000 14 Frame/Steel/Bolting/Welding PA RB T-BAR SEE ATTACHED NOTICE 10/4/2000 84 Rough Combo PA RB 10/3/2000 84 Rough Combo co RB CORR@ T-BAR SEE ATTACHED NOTICE 10/2/2000 84 Rough Combo PA RB 2ND FLR T-BAR 9/29/2000 14 Frame/Steel/Bolting/Welding AP TP 2ND FLR T-BAR BAR CEIL 9/29/2000 34 Rough Electric AP TP 2ND FLR CEIL LITES 9/29/2000 44 Rough/Ducts/Dampers AP TP 9/6/2000 14 Frame/Steel/Bolting/Welding AP RB FOR DOOR & LIGHT REVISION CORRECTIONS 9/5/2000 14 Frame/Steel/Bolting/Welding PA RB HAVE DOOR CHANGES APPROVED 9/5/2000 17 Interior Lath/Drywall AP RB 9/1/2000 17 Interior Lath/Drywall NR RB NEED FRAMING CORRECTIONS COMPLETED ti City of Carlsbad Bldg Inspection Request For: 10/10/2000 Permit# CB002486 Inspector Assignment: RB --- Title: ABTECH SYSTEMS Description: Tl -RECONFIGURE EXIST BUILDOUT Type:TI Job Address: Sub Type: COMM 2728 LOKER AV WEST Phone: 7604974559 Suite: Lot 0 Location: Inspector: ----- APPLICANT AVENT LISA Owner: CARLSBAD CROSSROADS LTD Remarks: WANTED A FRIDAY INSPECTION Total Time: CD-Description 19 Final Structural 29 Final Plumbing 39 Final Electrical 49 Final Mechanical 4 Associated PCRs Requested By: DAVID ERB Entered By: CHRISTINE Act Comments /J <:€> __ ~ occo/J~ J tha -/-£/,,tf1/L)~7v lns12ection Histo!)'. Date Description 10/4/2000 14 Frame/Steel/Bolting/Welding 10/4/2000 84 Rough Combo 10/3/2000 84 Rough Combo 10/2/2000 84 Rough Combo 9/29/2000 14 Frame/Steel/Bolting/Welding 9/29/2000 34 Rough Electric 9/29/2000 44 Rough/Ducts/Dampers 9/6/2000 14 Frame/Steel/Bolting/Welding 9/5/2000 14 Frame/Steel/Bolting/Welding 9/5/2000 17 Interior Lath/Drywall 9/1/2000 17 Interior Lath/Drywall 8/28/2000 24 RoughfTopout 8/24/2000 14 Frame/Steel/Bolting/Welding 8/24/2000 21 Underground/Under Floor 8/24/2000 34 Rough Electric Act PA PA co PA AP AP AP AP PA AP NR AP co PA AP lnsp Comments RB T-BAR SEE ATTACHED NOTICE RB RB CORR@ T-BAR SEE ATTACHED NOTICE RB 2ND FLR T-BAR TP 2ND FLR T-BAR BAR CEIL TP 2ND FLR CEIL LITES TP RB FOR DOOR & LIGHT REVISION CORRECTIONS RB HAVE DOOR CHANGES APPROVED RB RB NEED FRAMING CORRECTIONS COMPLETED RB RB RB UNDR SLAB OK ONLY RB WALLS ONLY Citv of Carlsbad · Final Building Inspection Dept: Building Engineering Planning CMWD St Lite Cf;.ii:e-J Plan Check #: Date: 10/10/2000 Permit#: CB002486 Permit Type: Tl Project Name: ABTECH SYSTEMS Sub Type: COMM Tl -RECONFIGURE EXIST BUILDOUT Address: 2728 LOKER AV WEST Lot: 0 Contact Person: DAVID ERB Phone: 7604974559 Sewer Dist: CA Water Dist: CA ·························································································································································· Inspected t Date l~u ~Disapproved: __ By: 7n . '/211 ~ Inspected: Approved: ' Inspected Date By: Inspected: Approved: Disapproved: __ Inspected Date By: Inspected: Approved: Disapproved: __ .......................................................................................................................................................... , Comments: _____________________________ _ EsGil Corporation In Partnership with Government for Building Safety DATE: 8/3/00 JURISDICTION: City of Carlsbad PLAN CHECK NO.: 00-2486 PROJECT ADDRESS: 2728 Loker Ave PROJECT NAME: Abtech Systems TI SET: II g_.AP-P~CAi'\T ~ CJ PLAN REVIEWER CJ FILE [g] The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. D The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. D The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. D The applicant's copy of the check list has t;>een sent to: [gj · Esgil Corporation staff did not advise the applicant that the plan check has been completed. D Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Telephone#: Date contacted: (by: ) Fax#: Mail Telephone Fax In Person D REMARKS: By: D01,1g Moody _ Enclosures: Esgil Corporation D GA D MB D EJ D PC 7/27/00 tmsmtl.dot 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858) 560-1468 + Fax (858) 560-1576 EsGil Corporation In Partnership with Government for Building Safety DATE: 7/13/00 JURISDICTION: City of Carlsbad PLAN CHECK NO.: 00-2486 PROJECT ADDRESS: 2728 Loker Ave PROJECT NAME: Abtech Systems TI SET:I CJ APPL~NT C° JURIS. CJ PLAN REVIEWER CJ FILE D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. D The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. [Z] The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. -· [Z] The applicant's copy of the check list has been sent to: Lisa Avent 1413 Lloyd Place, Escondido, Ca 92027 D Esgil Corporation staff did not advise the applicant that the plan check has been completed. [Z] Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Lisa Avent fr,11,) Telephone#: 760-740-0133 a.::tt~ Date GO~:,-l4-D6 (by:~) Fax#: Mail .,.,. Telephone v Fax In Person D REMARKS: By: Doug Moody Esgil Corporation D GA D MB D EJ D PC Enclosures: 7/6/00 trnsmtl.dot 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858) 560-1468 + Fax (858) 560-1576 City of Carlsbad 00-2486 7/13/00 PLAN REVIEW CORRECTION LIST TENANT IMPROVEMENTS PLAN CHECK NO.: 00-2486 OCCUPANCY: B/S TYPE OF CONSTRUCTION: IIIN ALLOWABLE FLOOR AREA: SPRINKLERS?: Unknown REMARKS: DATE PLANS RECEIVED BY JURISDICTION: 7/3/00 DATE INITIAL PLAN REVIEW COMPLETED: 7 / 13/00 FOREWORD (PLEASE READ): JURISDICTION: City of Carlsbad USE: Office /Warehouse ACTUAL AREA: 38,000 STORIES: 2 HEIGHT: OCCUPANT LOAD: 357 DATE PLANS RECEIVED BY ESGIL CORPORATION: 7/6/00 PLAN REVIEWER: Doug Moody This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Code sections cited are based on the 1997 UBC. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed up the recheck process, p'lease note on this list (or a copy) where each correction item has been addressed, i.e., _plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans. TENANT IMPROVEMENTS WITHOUT SPECIFIC ENERGY DATA OR POLICY SUPPLEMENTS (1997UBC) tiforw.dot City of Carlsbad 00-2486 7/13/00 Please make all corrections on the original tracings, as requested in the correction list. Submit three sets of plans for commercial/industrial projects (two sets of plans for residential projects). For expeditious processing, corrected sets can be · submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by · EsGil Corporation is complete. 1. Each sheet of the plans must be signed by the person responsible for their preparation, even though there are no structural changes. Business and Professions Code. Please have the persons responsible for the Mechanical and Electrical plans sign all pages. 2. Provide a statement on the Title Sheet of the plans stating that this project shall comply with the 1998 edition of the California Building Code {Title 24 ), which adopts the 1997 UBC, UMC and UPC and the 1996 NEC . . • 3. Detail disposal of main condensate drainage from air conditioning units. (UMC Section 309) 4. On the first sheet of the plans indicate: • Sprinklers: Yes or No • Present and proposed occupancy classifications of the warehouse, • The occupant load of the remodel area(s). 5. A complete description of the activities and processes that will occur in the warehouse should be provided. A listing of all hazardous materials should be included. The maJerials listing should be stated in a form that would make classification in Tables 3-D and 3-E possible. The building official may require a technical report to identify and develop methods of protection from hazardous materials. Section 307.1.6. a) Provide data on proposed hazardous material to be stored and used. UBC, Section 307 and UFC. b) Clearly show the types of hazardous material that are being stored or used, as per the UBC, Table 3-D and 3-E classifications. Provide the material safety data sheets (MSDS). City of Carlsbad 00-2486 7/13/00 c) Clearly show the amounts of each type of hazardous material to be stored and in use. d) Clearly show where in the buildings each type of hazardous material is being stored or used. e) Provide calculations for required containment in each area of the buildings, as per UBC, 307.2.5. f) Provide a written response to show how Spill Control and Drainage are being handled as required in UBC, Sections 307.2.3 & 307.2.4. g) Provide the required manual shutoff control for ventilation equipment as per UBC, Section 1202.2.3. 6. Please provide complete listing information for the spray booth shown in the warehouse. If not listed a third party installation report will be required for the approval of the construction and installation of the proposed rooms and station to approved standards. UMC, Section 302.2 7. Please provide a complete description of the spray foam area. Include the classifications and amounts of all materials used, show the storage location of the materials used 8. Exit doors should swing in the direction of exit travel when the area served has an occupant load of 50 or more. Section 1003.3.1.5. Please show the exit doors from room 116 to swing in the direction of travel. 9. Please show the dimension of the n"ew exit corridor providing the required level area on the side into which the doors swing; extending 18" inches past the strike edge for interior doors. Title 24. To speed up the review process, note on this list (or a copy) where each correction item has been add_ressed, i.e., plan sheet, note or detail number, calculation page, etc. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please indicate: Yes D No D The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Doug Moody at Esgil Corporation. Thank you. City of Carlsbad 00-2486 7/13/00 VALUATION AND PLAN CHECK FEE JURISDICTION: City of Carlsbad PREPARED BY: Doug Moody BUILDING ADDRESS: 2728 Loker Ave BUILDING OCCUPANCY: B/S BUILDING BUILDING AREA VALUATION (Sq.Ft.) PORTION MULTIPLIER Tl 38000 Citv Valuation Air ConditioninQ Fire Sprinklers .. TOTAL VALUE I PLAN CHECK NO.: 00-2486 DATE: 7 / 13/00 TYPE OF CONSTRUCTION: IIIN VALUE ($) I 1,482,000 1,482,000 1,482,000 D 199 UBC Building Permit Fee IZl Bldg. Permit Fee by ordinance: $ 4436.43 D 199 UBC Plan Check Fee IZl Plan Check Fee by ordinance: $ 2883.68 Type of Review: D Complete Review D Structural Only D Hourly D Repetitive Fee Applicable D Other: Esgil Plan Review Fee: $ 2306.94 Comments: Sheet 1 of 1 macvalue.doc 5100 BUILDING PLANCHECK CHECKLIST PLANCHECK NO.: CB DATE: 1/Jtfm BUILDING ADDREss: J]d"f__ LoJc!.ue_ ftv£. PROJECT DESCRIPTION: ---('-J:_ . fd-Jl);[j w~--- ASSESSOR'S PARCEL NUMBER: EST. VALUE: ENGINEERING DEPARTMENT APPROVAL DENIAL The item you have submitted for review has been approved. The approval is based on plans, information and/or specifications provided in your submittal; therefore any changes to these items after this date, including field modifications, must be reviewed by this office to insure continued conformance with applicable codes. Please review carefully all commenfsa1tached, as failure-to comply - with instructions in this report can result in suspension of permit to build. Cl Right-of-Way permit is required prior to construction of the following improvements: Please Se attached report of deficiencies marked with D. Make necessary corrections to plans or spec ons for compliance with applicable codes and standards. Submit corrected plans and/or specifications to · · e for review. Date: By: Date: By: Date: FOR OFl:JCIAL USE ONLY C. G AUTHORIZATION TO ISSUE BUILDING PERMIT· By: ATTACHMENTS D Dedication Application D Dedication Checklist D Improvement Application D Improvement Checklist D Future Improvement Agreement D Grading Permit Application D Grading Submittal Checklist D Right-of-Way Permit Application O Right-of-Way Permit Submittal Checklist and Information Sheet Date: ENGINEERING DEPT. CONTACT PERSON Name: KATHLEEN M. FARMER City of Carlsbad Address: 1635 Faraday Avenue, Carlsbad, CA 92008 Phone: (760) 602-2741 CFO INFORMATION Parcel Map No: Lots: Recordation: Carlsbad Tract: D Sewer Fee Information Sheet A-4 H:IWORDl1J685KIR!i'fil~d'ay,•~~@!m•c).@l:arlsbad, CA 920081-7314 • (760) 602-2720 • FAX (760) 602R6m@ll!! D D r D BUILDING PLANCHECK CHECKLIST SITE PLAN .. 1. Provide a fully dimensioned site plan drawn to scale. Show: A. North Arrow F. Right-of-Way Width & Adjacent Streets B. Existing & Proposed Structures G. Driveway widths C. Existing Stre.et Improvements H. Existing or proposed sewer lateral D. Property Lines I. Existing or proposed water service E. Easements J. Existing or proposed irrigation service 2. A. B. ,C. D. 3. A. 8. C. Show on site plan: Drainage Patterns 1. Building pad surface drainage must maintain a minimum slope of one percent towards an adjoining street or an approved drainage course. 2. ADD THE FOLLOWING NOTE: "Finish grade will provide a minimum po·sitive drainage of 2% to swale 5' away from building .. " Existing & Proposed Slopes and Topography Size, type, location, alignment of existing or proposed sewer and water service (s) that serves the project. Each unit requires a separate service, however, second dwelling units and apartment complexes are an exception. Sewer and water laterals should not be located within proposed driveways, per standards. Include on title sheet: Site address Assessor's Parcel Number Legal Description For commercial/industrial buildings and tenant improvement projects, include: total building square footage with the square footage for each different use, existing sewer permits showing square footage of different uses (manufacturing, warehouse, office, etc.) previously approved. EXISTING PERMIT NUMBER DESCRIPTION H:IWOROIDOCS\CHKI.Sl\Bulldlng Plancheck Cl<Jst Fonn (Generlc).doc 2 Rev, 7/14100 D D /AD D D BUILDING PLANCHECK CHECKLIST 3Ro DISCRETIONARY APPROVAL COMPLIANCE D 4a. Project does not comply with the following Engineering Conditior-is of approval for D D D Project No. _______________________ _ 4b. All conditions are in compliance. Date: __________ _ DEDICATION REQUIREMENTS 5. Dedication for all street Rights-of-Way adjacent to the building site and any storm drain or utility easements on the building site is required for all new buildings and for remodels with a value at or exceeding $ ______ , pursuant to Carlsbad Municipal Code Section 18.40.030. Dedication required as follows: ________________ _ Dedication required. Please have a registered Civil Engineer or Land Surveyor prepare the appropriate legal description together with an 8 ½" x 11" plat map and submit with a title report. All easement documents must be approved and signed by owner(s) prior to issuance of Building .Permit. Attached please find an application form and submittal checklist for the dedication process. Submit the completed application form with the required checklist items and fees to the Engineering Department in person. Applications will not be accept by mail or fax. Dedication completed by:____________ Date: ___ _ IMPROVEMENT REQUIREMENTS 6a. All needed public improvements upon and adjacent to the building site must be constructed at time of building construction whenever the value of the construction exceeds $ ______ _, pursuant to Carlsbad Municipal Code Section 18.40.040. Public improvements required as follows: _____________ _ Attached please find an application form and submittal checklist for the public improvement requirements. A registered Civil Engineer must prepare the appropriate improvement plans and submit them together with the requirements on the attached checklist to the Engineering Department through a separate plan check process. The completed application form and the requirements on the H:IWORD\OOCSICHKLSl\Bullding Plancheck Cklst Form (Generlc).doc 3 Rev. 7/14/00 1ST 2ND D D D D D D D D D D D D D ~D D D D D BUILDING PLANCHECK CHECKLIST checkli$t must be submitted in person. Applications by mail or fax are not accepted. Improvement plans must be approved, appropriate securities posted and fees paid prior to issuance of building permit. Improvement Plans signed by: _________ _ Date: ---- 6b. Construction of the public improvements may be deferred pursuant to Carlsbad Municipal Code Section 18.40. Please submit a recent property title report or current grant deed on the property and processing fee of $ _______ so we may prepare the necessary Future Improvement Agreement. This agreement must be signed, notarized and approved by the City prior to issuance of a Building permit. Future public improvements required as follows: 6c. Enclosed -please find your Future ,Improvement Agreement. Please return agreement signed and notarized to the Engineering Department. Future Improvement Agreement completed by: Date: 6d. No-.Public Improvements required. SPECIAL NOTE: Damaged or defective improvements found adjacent to building site must be repaired to the satisfaction of the City Inspector prior to occupancy. GRADING PERMIT REQUIREMENTS The conditions that invoke the need for a grading permit are found in Section 11.06.030 of the Municipal Code. 7a. Inadequate information available on Site Plan to make a determination on grading requirements. Include accurate grading quantities (cut, fill import, export). 7b. Grading Permit required. A separate grading plan prepared by a registered Civil Engineer must be submitted together with the completed application form attached. NOTE: The Grading Permit must be issued and rough grading approval obtained prior to issuance of a Building Permit. "' Grading Inspector sign off by: Date: ---------- 7c. Graded Pad Certification required. (Note: Pad certification may be required even if a grading permit is not required.) H:IWORD\OOCSICHKLST\Buildlng Planoheck Cklst Fann (Generlc).doc 4 Rev. 7/14/00 BUILDING PLANCHECK CHECKLIST 1ST 2ND 3RD D D D 7d .No Grading Permit required. D D D 7e.-lf-:grading is not required, write"No Grading" on plot plan. D D D D D D D D D D D MISCELLANEOUS PERMITS 8. A RIGHT-OF-WAY PERMIT is required to do work in City Right-of-Way and/or private work adjacent to the public Right-of-Way. Types of work include, but are not limited to: street improvements, tree trimming, driveway construction, tying into public storm drain, sewer and water utilities. Right-of-Way permit required for: 9. INDUSTRIAL WASTE PERMIT If your facility is located in the City of Carlsbad sewer service area, you need to contact the Carlsbad Municipal Water District, locaJed at 5950 El Camino Real, Carlsbad, CA 92008. District personnel can provide forms and assistance, and will check to see if your business enterprise is on the EWA Exempt List. You may telephone (760) 438-2722, extension 7153, for assistance. Industrial Waste permit accepted by: · ---------------Date: .... ------- 10. NPDES PERMIT Complies with the City's requirements of the National Pollutant Discharge Elimination System (NPDES) permit. The applicant shall provide best management practices to reduce surface pollutants to an acceptable level prior to discharge to sensitive areas. Plans for such improvements shall be approved by the City Engineer prior to issuance of grading or building permit, whichever occurs first. · 11. Cl Required fees are attached Cl No fees required WATER METER REVIEW 12a. Domestic (potable) Use Ensure that the meter proposed by the owner/developer is not oversized. Oversized meters are inaccurate during low-flow conditions. If it is oversized, for the life of the meter, the City will not accurately b_ill the owner for the water used. • All single family dwelling units received "standard" 1" service with 5/8" service. H:IWORD\DOCSICHKLS1'Bulldlng Plancheck Cldst Fann (Generlc),doc 5 Rev. 7/14/00 D D BUILDING PLANCHECK CHECKLIST • If owner/developer proposes a size other than the "standard", then ____ owrierldevelop.er __ mus.t provide potable water demand calculations, which include total fixture counts and maximum water demand in gallons per minute (gpm). A typical fixture count and water demand worksheet is attached. Once the gpm is provided, check against the "meter sizing schedule" to verify the anticipated meter size for the unit. • · Maximum service and meter size is a 2" service with a 2" meter. • If a developer is proposing a meter greater than 2", suggest the installation of multiple 2" services as needed to provide the anticipated demand. (manifolds are considered on case by case basis to limit multiple trenching into the street). 12b. Irrigation Use (where recycled water is not available) All irrigation' meters must be sized via irrigation calculations (in gpm) prior to approval. The developer must provide these calculations. Please follow these guidelines: --1." -If the projecf'is a newe-r-development-(newer :than-1998), check the recent improvement plans a·nd-observe if th-e new irrigation service is reflected on the improvement sheets. If so, at the water meter station, the demand in gpm may be listed there. Irrigation services are listed with a circled "I", and potable water is typically a circled "W". The irrigation service should look like: ., -.. -" ---- STA 1 +00 Install 2" service and --~--~-- 1.5: meter (estimated 100 gpm) 2. If the improvement plans do not list the irrigation meter and the service/meter will be installed via another instrument such as the building plans or grading plans (w/ a right of way permit of course), then the applicant must provide irrigation calculations for estimated worst-case irrigation demand (largest zone with the farthest reach). Typically, Larry Black has already reviewed this if landscape plans have been prepared, but the applicant must provide the calculations to you for your use. Once you have received a good example of irrigation calculations, keep a set for your reference. In general the calculations will include: • Hydraulic grade line • Elevation at point of connection (POC) • Pressure at POC in pounds per square inch (PSI) • Worse case zone (largest, farthest away from valve • Total Sprinkler heads listed (with gpm use per head) · • Include a 10% residual pressure at point of connection 3. In general, all major sloped areas of a subdivision/project are to be irrigated via separate irrigation meters (unless the project is only SFD with no HOA). As long as the project is located within the City recycled water H:IWORD\DOCSICHKLSnBulldlng Plancheck Cklst Fann (Generle).doc 6 Rev. 7/14/00 1sr D BUILDING PLANCHECK CHECKLIST service boundary, the City intends on switching these irrigation services/meters to a new recycled water line in the future. D D __ 12.c.. __ l_rrigation Use (wher:e rec¥cled. water is available) D DD 1. Recycled water meters are sized the same as the irrigation meter above. 2. If a project fronts a street with recycled water, then they should be connecting to this line to irrigate slopes within the development. For subdivisions, this should have been identified, and implemented on the improvement plans. Installing recycled water meters is a benefit for the applicant since they are exempt from paying the San Diego County Water Capacity fees. However, if they front a street which the recycled water is there, but is not live (sometimes they are charged with potable water until recycled water is available), then the applicant must pay the San Diego Water Capacity Charge. If within three years, the recycled water line is charged with recycled water by CMWD, then the applicant can apply for a refund to the San Diego County Water Authority (SDCWA) for a refund. However, let th-e applicant know that-we cannot guarantee the refund, and they musi deal with the SDCWA for this: · · '- 13. Additional Comments: H:\WORD\DOCSICHKLST\Buildlng Plancheck Cklst Fonn (Generic),doc 7 Rev. 7/14/00 ENGINEERING DEPARTMENT FEE CALCULATION WORKSHEET O Estimate based on unconfirmed information from applicant. D Calculati(!n based on building plancheck plan submittal. Address: :J7J.'6 L-ot<.:e~---Bldg. p~~mit No. C 13 t71) dJ.1/fb Date: ----- Types of Use: --"~--1-1-'f.~~-+- List types and square footages· for all uses. J--;r 11 ~ EDU's: --bQ~· _1.JJ!..~-- Types of Use: ______ _ EDU's: ----'-~ ADT CALCULATIONS: LisJ types and square footages for all uses. Types of Use: ~C{ ./4F9un~ts: /'J,., 1 / Types of Use: -------~./Units: ____ _ ADT's: ------ ADT's: ------ FEES REQUIRED: WITHIN CFD: DYES (no bridge & thoroughfare fee in District #1, reduced Traffic Impact Fee) D NO D 1. PARK-IN-LIEU FEE PARK AREA & #: ___ _ =$ ~ FEE/UNIT: ____ _ X NO.UNITS: __ _ D 2. TRAFFIC IMPACT FEE X~DT: t,,? ADT's/UNITS: =$ Lf3~,3«r ZONE TRANSPORTATION ADT'S ____ X $10 =$,C:-::::::::::: D 3. BRIDGE AND THOROUGHFARE FEE (DIST. #1 DIST. #2 DIST. #3 l =$,~ ADT's/UNITS:, ____ _ X FEE/ADT: ___ _ D 4. FACILITIES MANAGEMENT FEE ZONE:. ___ _ UNIT/SO.FT.:. ____ _ D 5. SEWER FEE / EDU's: {!) · Lf ~ BENEFIT AREA: ~, EDU's: C) , L{ ,_\ D 6. SEWER LATERAL ($2,500) D 7. DRAINAGE FEES PLDA. ___ _ ACRES: ____ _ D 8. POT ABLE WATER FEES UNITS CODE CONNECTION FEE Word\Docs\Mlsfonns\Fee Calculatlon Worksheet X FEE/SO.FT./UNIT:. ___ _ =$ ____ _ X FEE/EDU:. __ _ =$ '?57,,, Co v =$ l/~ .. 7 0 ~ =$ _____ _ HIGH ___ /LOW __ _ X FEE/AC: =$ ~. METER FEE SDCWA FEE IRRIGATION 1 of2 Rev. 7/14/00 -I \ -. ' \,_--\. -~-'\ ': '4;....'.:,;...,., -,> ,. ,.I.-, '. '. .•_ ,J. ·, . -\ ,, ... , ; .... ) -' - · /~1/ ) } . ~-· ·--\:.' ( -. '' ...... _. ' / .. ' l , -' .t,J. n,£ l . -• .• • ; • '· • ~ ·.1 '' ' . ' \ \ • . \ • . -• . ; J .\ .J ~ \l .\,-, ... \ .. ~'' . ,:.'.' i· -. -j • ,· " -;,: ,!&-' i . I I ,. ENGINEERING DEPARTMENT FEE CALCULATION WORKSHEET D 9. RECLAIMED WATER FEES UNITS CODE CONNECTION FEE TOT AL OF ABOVE FEES*: $ --------- * NOTE: This calculation sheet is NOT a complete list of all fees which may be due. Dedications and IJ!lprovements may also be required with Building Permits. ---------------~ --------------~----~ 2of2 Word\Docs\Mlsfonns\Fee Calculation Worksheet Rev. 7/14/00 .4 .Sl "' C ~ "' 'It ts ., .i::. t) C: C: C: "' "' "' a: a: a: D ~DD ~DD PLANNING DEPARTMENT BU.ILDING PLAN CHECK REVIEW CHECKLIST k Plan Check No. CB 00-;). '( Ek Address 'J1 'lg IA ell, N 'l //4 Planner Greg Fisher ---=---c...w...""---'-"~---..,....------Phone (760) 602-4629 ______ _ APN: ------------------------------ Type of Project & Use: _ Zoning: 'i?t1 General Plan: Net Project Density: ______ D_U~/A_C_ /J.:r_ Facilities Management Zone: ___ _ CFO lin/n11tl # Date of participation: Remaining net dev acres: Circle One --------- (For non-residential development: Type of land used created by this permit: ____________________ ) Legend: ~ Item Complete D Item Incomplete -Needs your action Environmental Review Required: YES NO TYPE ---- DATE OF COMPLETION: ______ _ Compliance with conditions of approval? If not, state conditions which require action. Conditions of Approval: Discretionary Action Required: YES NO TYPE ---- APPROVAL/RESO. NO. _____ DATE ___ _ PROJECT NO. _______ _ OTHER RELATED CASES: ---------------------- Compliance with conditions or approval? If not, state conditions which require action. Conditions of Approval: ----------------------- Coastal Zone Assessment/Compliance Project site located in Coastal Zone? YES NO CA Coastal ·commission Authority? YES NO If California Coastal Commission Authority: Contact them at -3111 Camino Del Rio North, Suite 200, San Diego CA 92108-1725; (619) 521-8036 Determine status (Coastal Permit Required or Exempt): Coastal Permit Determination Form already completed? YES · NO If NO, complete Coastal Permit Determination Form now. Coastal Permit Determination Log #: Follow-Up Actions: • 1) Stamp Building Plans as "Exempt" or "Coastal Permit Required" (at minimum Floor Plans). . 2) Complete Coastal Permit Determination Log as needed. H :\ADMIN\CO U NTER\BldgPlnchkRevChklst '/) . r/ {] o· D lnclusionary Housing Fee required: YES --NO (Effective date of lnclusionary Housing Ordinance -May 21, 1993./ Data Entry Completed? YES __ NO __ (A/P/Ds, Activity Maintenance, enter CB#, toolbar, Screens, Housing Fees, Construct Housing Y /N, Enter Fee, UPDATE!) Site Plan: D D D 1. Provide a fully dimensional site plan drawn to scare. Show: North arrow, property lines, easements, existing and proposed structures, streets, existing street improvements, right-of-way width, dimensional setbacks and existing topographical lines. D D D 2. Provide legal description of property and assessor's parcel number. Zoning: D D~D 1. Setbacks: Front: Required -------Shown -------Interior Side: Required -------Shown -------Street Side: Required -------Shown -------Rear: Required -------Shown ------- D D D 2. Accessory structure setbacks: Front: Required -------Shown· ------- Interior Side: Required -------Shown -------Street Side: Required _____ _ Shown -------Rear: Required -------Shown -------Structure separation: Required -------Shown ------- D D D 3. Lot Coverage: Required -------Shown ------- D D D 4. Height: Required -------Shown ------- Parking: Spaces Required -------Shown ------- Guest Spaces Required _______ Shown ______ _ Additional Comments ~ ~f!J) AL INTO COMPUTER H:\ADMIN\COUNTER\BldgPlnchkRevChklst SAMPLE PARKING CALCULATION CHART ·:·· PARKING REQUIRED: OFFICE 18,373 S.F.@ 4/1000 = 74 MANUFACTURING 22,937 S.F.@ 3/1000 = 69 WAREHOUSE 21,250 S.F.@ 1/1000 = 22 TOTAL: 165 PARKING PROVIDED: Regular 148 Compact 37 Accessible 8 Total:· 193 Carlsbad Fire Department 002486 1635 Faraday Ave. Carlsbad, CA 92008 Fire Prevention (760) 602-4660 Plan Review Requirements Category: Building Plan Reviewed by: Date of Report: 08/17/2000 ------------ Name: Lisa Avent Design Address: 1413 Lloyd Pl City, State: Escondido CA 92027 Plan Checker: Job #: 002486 Job Name: Abtech Systems Bldg #: CB002486 ------------------Job Address: 2728 Loker Av Ste. or Bldg. No. ~ Approved D Approved Subject to D Incomplete Review FD Job# The item you have submitted for review has been approved. The approval is based on pl.ans~·information ·and/ or specifications provided in your submittal; therefore any changes to these items after this' date,· includrng',field modifications, must be reviewed by this office to insure continued conformance with applicable· coaes ·and ·standards·. · Please revi~.w 9~re(ully all comments . ,. attached as failure to comply with instructions in this r'epo'rt cah result in suspension of permit to construct or install improvements. The item you have submitted for review has been approved subject to the attached conditions. The approval is based on plans, information and/or specifications provided in your submittal. Please review carefully all comments attached, as failure to comply with instructions in this report can result in suspension of permit to construct or install improvements. Please resubmit to this office the necessary plans and / or specifications required to indicate compliance with applicable codes and standards. The item you have submitted for review is incomplete. At this time, this office cannot adequately conduct a review to determine compliance with the applicable codes and I or standards. Please review carefully all comments attached. Please resubmit the necessary plans and/ or specifications to this office for review and approval. 1st 002486 . 2nd FD File# 3rd Other Agency ID aarfs1bad Fire Department 002486 1635 Faraday Ave. Carlsbad, CA 92008 Plan Review Requirements Category: Fire Prevention (760) 602-4660 Date of Report: 07/11/2000 Building Plan Reviewed by: ~ ------------ Name: Lisa Avent Design Address: 1413 Lloyd Pl City, State: Escondido CA 92027 Plan Checker: Job #: 002486 ------- Job Name: Abtech Systems iSLdg #: CB002486 / ------------------Job Address: 2728 Loker Av 8 t e. or Bldg. No. D Approved D Approved Subject to ~ Incomplete Review FD Job# The item you have submitted for review has been approved. The approval is based on plans, information and I or specifications provided in your submittal; therefore any changes to these items after this date, including field modifications, must be reviewed by this office to insure continued conformance with applicable codes and standards. Please review carefully all comments attached as failure to comply with instructions in this report can result in suspension of permit to construct or install improvements. The item you have submitted for review has been approved subject to the · attached conditions. The approval is based on plans, information and/or specifications provided in your submittal. Please review carefully all comments attached, as failure to comply with instructions in this report can result in suspension of permit to construct or install improvements. Please resubmit to this office the necessary plans and/ or specifications required to indicate compliance with applicable codes and standards. The item you have submitted for review is incomplete. At this time, this office cannot adequately conduct a review to determine compliance with the applicable codes and / or standards. Please review carefully all comments attached. Please resubmit the necessary plans and / or specifications to this office for review and approval. 1st 002486 2nd FD File# 3rd Other Agency ID Requ~ments Category: .. -Building Plan Page 1 Requirement: Pending 05.14 Provide Technical Report To determine the acceptability of technologies, processes, products, facilities, materials and uses attending the design, operation or use of a building or premises subject to the inspection of the department, the Chief is authorized to require the owner or the person in possession or control of the building or premises to provide, without charge to the jurisdiction, a technical opinion and report. The opinion and report shall be prepared by a qualified engineer, specialist, laboratory or fire-safety specialty organization acceptable to the Chief and the owner and shall analyze the fire-safety properties of the design, operation or use of the building or premises and the facilities and appurtances situated thereon, to recommend necessary changes. 07/11/00 -' TITLE 24 REPORT Title 24 Report for: Abtech Systems 2728 Loker Avenue West Carlsbad, CA 92008 Project Designer: Report Prepared By: Steve Balderrama, CEPE Stueven Engineering Consultants 425 W. 5th Ave. Suite 103 Escondido, CA 92025 (760) 735-8577 Job Number: Date: 06/29/2000 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 1998 Building Energy Efficiency Standards. This program developed by Gabel Dodd/EnergySoft, LLC (415) 883-5900. EnergyPro 2.1 By EnergySoft Job Number: User Number: 3429 Cover Page Table of Contents TABLE OF CONTENTS Form ENV-1 Certificate of Compliance Form ENV-2 Overall Envelope Method Form ENV-MM Envelope Mandatory Measures Form MECH-1 Certificate of Compliance Form MECH-2 Mechanical Equipment Summary Form MECH-3 Mechanical Ventilation Form MECH-4 Mechanical Sizing and Fan Power Form MECH-MM Mechanical Mandatory Measures EnergyPro 2.1 By EnergySoft Job Number: 1 2 3 5 10 11 13 15 16 19 User Number: 3429 !CERTIFICATE ·OF COMPLIANCE Part 1 of 2 ENV-1j PROJECT NAME DATE Abtech Systems 06/29/2000 PROJECT ADDRESS 2728 Loker Avenue West Carlsbad Building Permit # PRINCIPAL DESIGNER -ENVELOPE TELEPHONE DOCUMENTATION AUTHOR TELEPHONE Checked by/Date Stueven Engineering Consultants (760) 735-8577 Enforcement Adencv Use GENERAL INFORMATION DATE OF PLANS !BUILDING CONDITIONED FLOOR AREA I CLIMATE ZONE 7 5,633 Sq.Ft. BUILDING TYPE [X] NONRESIDENTIAL D HIGH RISE RESIDENTIAL D HOTEUMOTEL GUEST ROOM PHASE OF CONSTRUCTION D NEW CONSTRUCTION D ADDITION IX] ALTERATION D EXISTING + ADDITION METHOD OF ENVELOPE D COMPONENT IX] OVERALLENVELOPE D PERFORMANCE COMPLIANCE STATEMENT OF COMPLIANCE This Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations. This certificate applies only to building envelope requirements. The documentation preparer hereby certifies that the document is accurate and complete. --{\ DOCUMENTATION AUTHOR ISJ9WEUR~w k IUr. -Cir:;--1 t::> t'L-lb,h_q/i;:o Steve Balderrama CEPE 10L.--t The Principal Envelope Designer hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application. The proposed building has been designed to meet the envelope requirements contained in Sections 110, 116 through 118, and 140, 142, 143 or 149 of Title 24, Part 6. Please check one: D I hereby affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code to sign this document as the person responsible for its preparation; and that I am licensed in the state of California as a civil engineer or mechanical engineer, or I am a licensed architect. D I affirm that I am eligible under the exemption to Division 3 of the Business and Professions Code by Section 5537.2 or 6737.3 to sign this document as the person responsible for its preparation; and that I am a licensed contractor performing this work. D I affirm that I am eligible under Division 3 of the Business and Professions Code to sign this document because it pertains to a structure or type of work described as exempt pursuant to Business and Professions Code Sections 5537, 5538, and 6737.1. PRINCIPAL ENVELOPE DESIGNER -NAME I SIGNATURE IDATE ILIC.# . ENVELOPE MANDATORY MEASURES Indicate location on plans of Note Block for Mandatory Measures I I INSTRUCTIONS TO APPLICANT For detailed instructions on the use of this and all Energy Efficiency Standards compliance forms, please refer to the Nonresidential Manual published by the California Energy Commission. ENV-1: Required on plans for all submittals. Part 2 may be incorporated in schedules on plans. ENV-2: Used for all submittals; choose appropriate version depending on method of envelope compliance. ENV-3: Optional. Use if default U-values are not used. Choose appropriate version for assembly U-value to be calculated. EnergyPro 2.1 By EnergySoft User Number: 3429 Job Number: Page:3 of 20 IENVELOPE COMPLIANCE SUMMARY Part 2 of 2 ENV-11 I PROJECT NAME Abtech Systems !DATE 06/29/2000 I OPAQUE SURFACES Solar Surface Framing Act. Gains # Type Type Area U-Val. Azm. Tilt Y/N Form 3 Reference Location / Comments 1 Wall None 250 0.730 45 90 X 6" Concrete Wall Como. Room 116 2 Demisina Metal 980 0.169 0 90 X R-11 Demisina Wall -Metal Como. Room 116 (faces Warehouse) 3 Roof Wood 2 300 0.043 0 0 X R-19 on Acoustical Tile Como. Room 116 4 Wall None 92 0.730 225 90 X 6" Concrete Wall Open Office 215 5 Wall None 346 0.730 270 90 X 6" Concrete Wall Open Office 215 6 Demisina Metal 801 0.169 0 90 X R-11 Demisina Wall-Metal Open Office 215 (faces Warehouse) 7 Roof Wood 3,168 0.043 0 0 X R-19 on Acoustical Tile Ooen Office 215 8 Wall None 60 0.730 225 90 X 6" Concrete Wall Office 216 9 Roof Wood 165 0.043 0 0 X R-19 on Acoustical Tile Office216 FENESTRATION SURFACES Act. # Type Area U-Val. Azm. SHGC Glazing Type Location / Comments 1 Window 25 1.280 225 0.56 Solarcool Coated Azurlite Ooen Office 215 2 Window 230 1.280 270 0.56 Solarcool Coated Azurlite Ooen Office 215 3 Window 75 1.280 225 0.56 Solarcool Coated Azurlite K:>ffice 216 EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hat. LExt.RExt. Dist. Len. Hat. Dist. Len. Hat. 1 None 0.76 2 None 0.76 3 None 0.76 EnergyPro 2.1 By EnergySoft User Number: 3429 Job Number: Page:4 of 20 lovERALL ENVELOPE METHOD PROJECT NAME Abtech S stems WINDOW AREA TEST A DISPLAY PERIMETER I 8. GROSS EXTERIOR WALL AREA I C. GROSS EXTERIOR WALL AREA I D. ENTER LARGER OF A or 8 E. ENTER PROPOSED WINDOW AREA OJ ftX 6 = I 1,0781 sf X 0.40 = I 1,078J sf X 0.10 = J I I Part 1 of 5 ENV-2 I DATE 06/29/2000 d sf DISPLAYAREA 431 sf 40% AREA 1 Oij sf MINIMUM STND. AREA 431 sf MAXIMUM STND. AREA 33d sf PROPOSED AREA IF EIS GREATER THAN DOR LESS THAN C, PROCEED TO THE NEXT CALCULATION FOR THE WINDOW AREA ADJUSTMENT. IF NOT, GO TO PART 2 OF 5. 1. IF E GREATER THAN D: WINDOW D. MAXIMUM STANDARD AREA E. PROPOSED WINDOW AREA ADJUSTMENT FACTOR I I+ I I= I I (IF E=0, THEN ENTER C) GO TO PART 4 OF 4 TO CALCULATE ADJUSTED AREAS. 2. IF LESS THAN C: WINDOW C. MAXIMUM STANDARD AREA E. PROPOSED AREA ADJUSTMENT FACTOR I I+ I I= I I (IF E=0, THEN ENTER 1) GO TO PART 5 TO CALCULATE ADJUSTED AREAS. SKYLIGHT ARFA TEST ATRIUM HEIGHT Sc FT f F <= 5 IF> 55'1 ALLOWE % = 5 ALLOW D % = 10 I I I 5o/~ x I s,6331 = I 2821 ALLOWED% GR. ROOF AREA STANDARD SKYLIGHT AREA i I 01 PROPOSED SKYLIGHT AREA IF THE PROPOSED SKYLIGHT AREA IS GREATER THAN THE STANDARD SKYLIGHT AREA, PROCEED TO THE NEXT CALCULATION FOR THE SKYLIGHT AREA ADJUSTMENT. IF NOT, GO TO PART 2 OF 5. 1. IF PROPOSED SKYLIGHT AREA> STANDARD SKYLIGHT AREA: SKYLIGHT STANDARD SKYLIGHT AREA PROPOSED SKYLIGHT AREA ADJUSTMENT FACTOR I I+ I I = I I GO TO PART 5 OF 5 TO CALCULATE ADJUSTED AREAS. EnergyPro 2.1 By EnergySoft User Number: 3429 Job Number: Page:5 of 20 fOVERALL ENVELOPE METHOD Part 2 of 5 ENV .. 2 f PROJECT NAME DATE Abtech Svstems 06/29/2000 OVERALL HEAT LOSS 0 @] @] ~ ~ [I] @] G] PROPOSED STANDARD TABLE ASSEMBLY NAME HEAT VALUES UA AREA* UA (e.g. Wall-1, Floor-1) AREA CAPACITY U-VALUE y N (BXD) (Adjusted) U-VALUE (FXG) Northeast 250 15.17 0.730 D [Z] 182.5 250 0.69( 172.5 Roof 2,300 1.47 0.043 [Z] D 99.9 2,300 0.07E 179.4 Southwest 92 15.17 0.730 D [Z] 67.2 92 0.69C 63.5 Window -No Overhang 25 1.280 D [Z] 32.0 25 1.230 30.8 West 346 15.17 0.730 D [Z] 252.6 346 0.69( 238.7 Window -No Overhang 230 1.280 D [Z] 294.4 230 1.23( 282.9 Roof 3,168 1.47 0.043 [Z] D 137.6 3,168 0.07E 247.1 Southwest 60 15.17 0.730 D [Z] 43.8 60 0.69C 41.4 Window -No Overhang 75 1.280 D [Z] 96.0 75 1.230 92.2 Roof 165 1.47 0.043 [Z] D 7.2 165 O.Q7~ 12.9 D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D * If Window and/or Skylight Area Adjustment is Required, Column E shall be 1,213 This Page Total 1,361 use Adjusted Areas from Part 5 of 5. no greater than Column H 1,213 Building Total 1,361 EnergyPro 2.1 By EnergySoft User Number: 3429 Job Number: Page:6 of 20 !OVERALL ENVELOPE METHOD Part 3 of 5 ENv .. 2 j PROJECT NAME /DATE Abtech Svstems 06/29/2000 OVERALL HEAT GAIN FROM CONDUCTION 0 ~ @] @] [fil [] @] [ill OJ 0 PROPOSED STANDARD TABLE HEAT HEAT ASSEMBLY NAME HEAT U-VALUES GAIN AREA* GAIN Q Q (e.g. Wall-1, Floor-1) AREA TF CAPACITY VALUE y N {BxCxEl (Adjusted ) U-VALUE TF {GxHxll Northeast 250 15 15.17 0.730 D [Z] 2,737 250 0.690 15 2,588 Roof 2,300 27 1.47 0.043 [Z] D 2,697 2,300 0.078 27 4,844 Southwest 92 15 15.17 0.730 D [Z] 1,007 92 0.690 15 952 Window -No Overhang 25 27 1.280 D [Z] 864 25 1.230 27 830 West 346 15 15.17 0.730 D [Z] 3,788 346 0.690 15 3,581 Window -No Overhang 230 27 1.280 D [Z] 7,949 230 1.230 27 7,638 Roof 3,168 27 1.47 0.043 [Z] D 3,715 3,168 0.078 27 6,672 Southwest 60 15 15.17 0.730 D [Z] 657 60 0.690 1.5 621 Window -No Overhang 75 27 1.280 D [Z] 2,592 75 1.230 27 2,491 Roof 165 27 1.47 0.043 [Z] D 194 165 0.078 27 347 D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D * If Window and/or Skylight Area Adjustment is Required, 26,201 This Page Total 30,564 use Adjusted Areas from Part 5 of 5. 26,201 Building Total 30,564 I I EnergyPro 2.1 By EnergySoft User Number: 3429 Job Number: Page:7 of20 !OVERALL ENVELOPE METHOD Part 4 of 5 ENV-21 PROJECT NAME DATE Abtech S stems 06/29/2000 !OVERALL HEAT GAIN FROM RADIATION OJ 0 PROPOSED STANDARD WINDOW/SKYLIGHT NAME WEIGHTING OVERHANG HEAT GAIN AREA* RSHG HEAT GAIN Q Q ~e.g. Wind-1, Sky-1) ORIENT. FACTOR AREA SF SHGC H V Window -No Overhana s 1.31 2t 123 0.56 Window -No Overhana w 1.34 23( 123 0.56 Window -No Overhana s 1.31 71 123 0.56 *If Window and/or Skylight Area ** Only SHGC is Column I must be Adjustment is Required, use used for Skylights less than column M Adjusted Areas from Part 5 of 5. EnergyPro 2.1 By EnergyPro User Number: 3429 HN OHF (BxCxDxExH) 2256 21 229 6,767 30,2521 30,2521 (ADJUSTED) (orSHGC**) SF 25 0.6 2 123 230 0.62 75 0.62 This Page Total Building Total 123 123 / Total Heat Gain From Conduction/ ~--26~,2_0~1. (From Part 3) . (BxJxKxL) 2498 23,503 7 493 33,4931 33,4931 30,5641 ---56-,4-5~31 Total Heat Gain --6-4,-05~d Job Number: Page:8 of 20 I OVERALL ENVELOPE METHOD Part 5 of 5 ENV-2f PROJECT NAME DATE Abtech S stems 0612912000 WINDOW AREA ADJUSTMENT CALCULATIONS [ZJ CHECK IF NOT APPLICABLE (See Part 1 of 5.) [fil [I] @] 0 @] @] @] WINDOW ADJUSTED ADJUSTED ADJUST. WINDOW WALL WALL NAME I ORIENTATION I GROSS DOOR WINDOW FACTOR AREA AREA (e.g. Wall-1, Wall-2) IN IE Is I w I AREA AREA AREA (From Part 1) (DX E) B -(F + C) DODD DODD DODD DODD DODD DODD DODD DODD DODD DODD DODD DODD DODD DODD DODD DODD DODD DODD I TOTALS I I I I I NIAi I I SKYLIGHT AREA ADJUSTMENT CALCULATIONS [x] CHECK IF NOT APPLICABLE (See Part 1 of 5.) @] [fil [I] 0 @] @] SKYLIGHT ADJUSTED ADJUSTED ADJUST. SKYLIGHT ROOF ROOFNAME GROSS SKYLIGHT FACTOR AREA AREA (e.g. Roof-1, Roof-2) AREA AREA (From Part 1) (CXD) (B -E) I TOTALS 11 I I NIAi I I EnergyPro 2.1 By EnergySoft User Number 3429 Job Number: Page:9 of 20 !ENVELOPE MANDATORY MEASURES ENV-MMI PROJECT NAME DATE Abtech S stems 06/29/2000 DESCRIPTION Designer Enforcement D § 118(a) Installed Insulating Material shall have been certified by the manufacturer to comply with the California Quality Standards for insulating material, Title 20, Chapter 4, Article 3. D § 118(c) All Insulating Materials shall be installed in compliance with the flame spread rating and smoke density requirements of Sections 2602 and 707 of Title 24, Part 2. D § 117(a) All Exterior Joints and openings in the building that are observable sources of air leakage shall be caulked, gasketed, weatherstripped or otherwise sealed. D § 116(b) Site Constructed Doors, Windows and Skylights shall be caulked between the unit and the building, and shall be weatherstripped (except for unframed glass doors and fire doors). D § 116(a)1 Manufactured Doors and Windows installed shall have air infiltration rates not exceeding those shown in Table Number 1-E. of the Standards. Manufactured fenestration products must be labeled for U-value according to NFRC procedures. D § 118(e) Demising Walls in Nonresidential Buildings: The opaque portions of framed demising walls in nonresidential buildings shall have insulation with an installed R-value of no less than R-11 between framing members. EnergyPro 2.1 By EnergySoft User Number: 3429 Job Number: Page: 1 O of 20 (CERTIFICATE OF COMPLIANCE Part 1 of 2 MECH-11 PROJECT NAME DATE Abtech Systems 06/29/2000 PROJECT ADDRESS 2728 Loker Avenue West Carlsbad Building Permit# PRINCIPAL DESIGNER -MECHANICAL TELEPHONE Stueven Engineering Consultants (760) 735-8577 DOCUMENTATION AUTHOR TELEPHONE Checked by/Date Stueven Engineering Consultants (760) 735-8577 Enforcement Agency Use GENERAL INFORMATION DATE OF PLANS I BUILDING CONDITIONED FLOOR AREA I CLIMA?E ZONE 5,633sq.Ft. BUILDING TYPE [Z] NONRESIDENTIAL D HIGH RISE RESIDENTIAL D HOTEUMOTEL GUEST ROOM PHASE OF CONSTRUCTION D NEW CONSTRUCTION D ADDITION [X] ALTERATION D EXISTING + ADDITION METHOD OF MECHANICAL [Z] PRESCRIPTIVE D PERFORMANCE COMPLIANCE PROOF OF ENVELOPE COMPLIANCE D PREVIOUS ENVELOPE PERMIT 0 ENVELOPE COMPLIANCE ATTACHED STATEMENT OF COMPLIANCE This Certificate of Compliance lists the building features and performance specifications need to comply with Title 24, Parts 1 and 6 of the California Code of Regulations. This certificate applies only to building mechanical requirements. The documentation preparer hereby certifies that the documation is ~CJ11rf and complete. DOCUMENTATION AUTHOR l~f~URWa./'--I oq-u:,/4cJ Steve Balderrama CEPE " ,_ -::as--1"i""1 L The Principal Mechanical Designer hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application. The proposed building has been designed to meet the mechanical requirements contained in Sections 110 through115, 120 through 124, 140 through 142, 144 and 145. Please check one: ~ hereby affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code to sign this ocument as the person responsible for its preparation; and that I am licenced in the State of California as a civil engineer, or mechanical engineer or I am a licensed architect. D I affirm that I am eligible under the exemption to Division 3 of the Business and Professions Code by Section 5537 .2 or 6737.3 to sign this document as the person responsible for its preparation; and that I am a licensed contractor performing this work. D I affirm that I am eligible under the exemption to Division 3 of the Business and Professions Code to sign this document because it pertains to a structure or type of work described persuant to Business and Professions Code sections 5537, 5538, and 6737.1. ~ PRINCIPAL MECHANICAL DESIGNER· NAME I SIGNATUJi E't W1, ~ l~Tft.-i (to ILIC.# Stueven Enaineerina Consultants lM. ltB~8 MECHANICAL MANDATORY MEASURES .. , - Indicate location on plans of Note Block for Mandatory Measures I INSTRUCTIONS TO APPLICANT For detailed instructions on the use of this and all Energy Efficiency Standards compliance forms, please refer to the Nonresidential Manual published by the California Energy Commission. MECH-1: Required on plans for all submittals. Parts 2 may be incorporated in schedules on plans. MECH-2: Required for all submittals, but form does not have to be completed if location of mechanical equipment schedule is indicated on the form per Section 4.3.3. MECH-3: Required for all submittals unless required outdoor ventilation rates and airflows are shown on plans per Section 4.3.4. MECH-4: Required for Prescriptive submittals. EnergyPro 2.1 By EnergySoft User Number: 3429 Job Number: Page: 11 of 20 lcERTIFICATE OF COMPLIANCE Part 2 of 2 MECH-1f PROJECT NAME 'DATE I Abtech Systems 06/29/2000 SYSTEM FEATURES I MECHANICAL SYSTEMS I I SYSTEM NAME I I Existing 7.5 Ton Open Office 215 I Office 216 I NOTE TO FIELD TIME CONTROL Programmable Switch Programmable Switch Programmable Switch SETBACK CONTROL No Setback Reauired No Setback Reauired No Setback Reauired ISOLATION ZONES n/a n/a n/a HEAT PUMP THERMOSTAT? Yes Yes Yes ELECTRIC HEAT? 0.0kW 0.0kW 0.0kW FAN CONTROL Constant Volume Constant Volume Constant Volume VAV MINIMUM POSITION CONTROL? No No No SIMULTANEOUS HEAT/COOL? No No No HEATING SUPPLY RESET Constant Temp Constant Temp Constant Temp COOLING SUPPLY RESET Constant Temp Constant Temp Constant Temp VENTILATION Air Balance Air Balance Air Balance OUTDOOR DAMPER CONTROL Auto Auto Auto ECONOMIZER TYPE No Economizer No Economizer No Economizer DESIGN AIR CFM (MECH-3, COLUMN H) 345 cfm 475 cfm 25cfm HEATING EQUIPMENT TYPE Heat Pump Heat Pump Heat Pump HEATING EQUIPMENT EFFICIENCY 6.8 HSPF 7.0 HSPF 6.6 HSPF COOLING EQUIPMENT TYPE Packaged DX Packaged DX Packaged DX COOLING EQUIPMENT EFFICIENCY 8.9EER 10.0 SEER/ 8.6 EER 10.0 SEER/9.1 EER Existing 7.5 Ton Unit CARRIER 50HS-060 CARRIER 50HS-018 MAKE AND MODEL NUMBER HEATING DUCT LOCATION R-VALUE Ducts in Attic 4.2 Ducts in Attic 4.2 Ducts in Attic 4.2 COOLING DUCT LOCATION R-VALUE Ducts in Attic 4.2 Ducts in Attic 4.2 Ducts in Attic 4.2 DUCT TAPE ALLOWED? Yes Yes Yes PIPE TYPE (SUPPLY, RETURN, ETC.) PIPE INSULATION REQUIRED? Yes Yes Yes I CODE TABLES: Enter code from table below into columns above. I HEAT PUMP THERMOSTAT? TIME CONTROL SETBACK CTRL. ISOLATION ZONES FAN CONTROL ELECTRIC HEAT? S: Prog. Switch H: Heating Enter Number of I: Inlet Vanes 0: Occupancy C:Cooling Isolation Zones. P: Variable Pitch VAV MINIMUM POSITION CONTROL? Sensor B: Both V:VFD Y:Yes M: Manual Timer 0: Other C: Curve SIMULTANEOUS HEAT/ COOL? N:No HEAT AND COOL SUPPLY RESET? VENTILATION OUTDOOR DAMPER ECONOMIZER O.A. CFM B: Air Balance A:Auto A:Air Enter Outdoor Air HIGH EFFICIENCY? C: Outside Air Cert. G: Gravity W:Water CFM. M: Out. Air Measure # N: Not Required Note: This shall be nc DUCT TAPE ALLOWED? D: Demand Control less than Col. H on PIPE INSULATION REQUIRED? N: Natural MECH-3. NOTES TO FIELD -For Buildina Denartment Use Onlv EnergyPro 2.1 By EnergySoft User Number: 3429 Job Number: Page: 12 of 20 fMECHANICAL EQUIPMENT SUMMARY Part 1 of 2 MECH-2j PROJECT NAME I DAT1)6/29/2000 Abtech Svstems CHILLER AND TOWER SUMMARY PUMPS Tot. Motor Drive Pump Equipment Name Equipment Type Qty. Efficiency Tons Qty GPM BHP Eff. Eff. Control DHW / BOILER SUMMARY Energy Factor Standby TANKINSUL. Rated Vol. or Recovery Loss or Ext. System Name System Type Distribution Type Qt}! Input (Gals.) Efficiency Pilot R-Val. CENTRAL SYSTEM RATINGS HEATING COOLING Aux. Svstem Name Svstem Tvoe Qtv. Outout kW Eff. Outout Sensible Efficiencv Economizer Type Existing 7.5 Ton Unit Packaged DX 1 96,000 0.0 6.8HSPF 90,000 63,000 8.9 EER No Economizer CARRIER 50HS-060 Packaged DX 2 57,000 0.0 7.0HSPF 57,500 40,250 10.0 SEER/ 8.6 EER No Economizer CARRIER 50HS-018 Packaged DX 1 17,800 0.0 6.6HSPF 19,000 13,300 10.0 SEER/ 9.1 EER No Economizer CENTRAL SYSTEM FAN SUMMARY SUPPLY FAN RETURN FAN Motor Drive Motor Drive Svstem Name Fan Tvoe Motor Location CFM BHP Eff. Eff. CFM BHP Eff. Eff. Existing 7.5 Ton Unit Constant Volume Blow-Through 3,000 2.00 84.0% 97.0% none CARRIER 50HS-060 Constant Volume Blow-Through 2,000 1.00 82.5% 100.0% none CARRIER 50HS-018 Constant Volume Blow-Through 600 0.25 77.0% 100.0% none EnergyPro 2.1 By EnergySoft User Number: 3429 Job Number: Page: 13 of 20 fMECHANICAL EQUIPMENT SUMMARY Part 2 of 2 MECH-21 PROJECT NAME I DAT1)6/29/2000 Abtech Svstems ZONE TERMINAL SUMMARY VAV TERMINAL BOX TERMINAL FAN BASEBOARD Min.CFM Reheat Coil Flow Motor Drive Zone Name Svstem Tvne Qtv. Ratio Tvoe DeltaT Ratio CFM BHP Eff. Eff. Type Output EXHAUST FAN SUMMARY E [M.1111 SI t-.&lN 1-XHA' "'I 1-/.lN Motor Drive Motor Drive Room Name Qtv. CFM BHP Eff. Eff. Room Name Qtv. CFM BHP Eff. Eff. EnergyPro 2.1 By EnergySoft User Number: 3429 Job Number: Page: 14 of 20 !MECHANICAL VENTILATION MECH-31 PROJECT NAME DATE Abtech S stems 06/29/2000 iMECHANICAL VENTILATION [u Q] -AREA BASIS OCCUPANCY BASIS REQ'D DESIGN COND. MIN. NO. CFM MIN. O.A. OUTDOOR VAV iTRANS ZONE/SYSTEM AREA CFM CFM OF PER CFM (MAX OF AIR MIN. FER (SF) PER SF (Bx C) PEOPLE PERSON (ExF) DORG) CFM RATIO AIR - Comp. Room 116 2,300 0.15 345 345 345 - Existing 7.5 Ton Total 345 345 - Open Office 215 3,168 · 0.15 475 475 475 - Open Office 215 Total 475 475 - Office216 165 0.15 25 25 25 - Office216 Total 25 25 - I--- I--- ~ - - I--- I--- I--- ~ ~ - - - 1--- ~ - - - - - 1--- - ~ Minimum Ventilation Rate per Section 121, Table 1-F. Based on Expected Number of Occupants or at least 50% of Chapter 10 1997 UBC Occupant Density. Must be greater than or equal to H, or use Transfer Air. Design Outdoor Air includes ventilation from Supply Air System & Room Exhaust Fans. Must be greater than or equal to (H minus I), and, for VAV, greater than or equal to (H-J). EnergyPro 2.1 By EnergySoft User Number: 3429 Job Number: Page:15 of 20 !MECHANICAL SIZING AND FAN POWER MECH-41 PROJECT NAME DATE Abtech Systems 06/29/2000 SYSTEM NAME FLOOR AREA Existing 7.5 Ton 2,300 NOTE: Provide one copy of this form for each mechanical system when using the Prescriptive Approach. !SIZING AND EQUIPMENT SELECTION 1. DESIGN CONDITIONS: -OUTDOOR DRY BULB TEMPERATURE -OUTDOOR WET BULB TEMPERATURE -INDOOR, DRY BULB TEMPERATURE 2. SIZING: -DESIGN OUTDOOR AIR -ROOM LOADS -RETURN VENTED LIGHTING -RETURN AIR DUCTS -RETURN FAN -SUPPLYFAN -SUPPLY DUCTS (APPENDIX C) (APPENDIX C) SEE ASHRAE CHAPTER 8, 1993 OR APPENDIX B 3451 CFM (MECH 3; COLUMN I) ~---~ TOTALS SAFETY/ WARM-UP FACTOR MAXIMUM ADJUSTED LOAD (TOTALS FROM ABOVE x SAFETY/ WARM-UP FACTOR) 3. SELECTION: INSTALLED EQUIPMENT CAPACITY (ADJUSTED FOR DESIGN CONDITIONS) IF INSTALLED CAPACITY EXCEEDS MAXIMUM ADJUSTED LOAD, EXPLAIN FAN POWER CONSUMPTION [Kl [fil @] @] []] DESIGN EFFICIENCY NUMBER FAN DESCRIPTION BRAKE HP MOTOR DRIVE OF FANS Supply Fan 2.000 . 84.0% 97.0% 1 COOLING 83°F 68°F 74 °F 2.985 43,776 0 2,189 0 0 2,189 51, 1381 1.21 61,877 59,8941 Btu/ Hr [£] PEAK WATTS BxEx746/(CXD 1,831 NOTE: Include only fan systems exceeding 25 HP (see Section 144). TOTALS I 1,831I I Total Fan System Power Demand may not exceed 0.8 Watts/cfm for TOTAL FAN SYSTEM I constant volume systems or 1.25 Watts/cfm for VAV systems. POWER DEMAND WATTS/CFM EnergyPro 2.1 By EnergySoft User Number 3429 Job Number: HEATING 34°F 13 270 21 18' n/a 1,059 0 0 1,059 36,5691 1.43 52,294 73,5441 Btu/ Hr @] CFM (Supply Fans) 3,000 3,oool 0.6101 Col. F / Col. G Page: 16 of 20 fMECHANICAL SIZING AND FAN POWER MECH-41 PROJECT NAME DATE Abtech Systems 06/29/2000 SYSTEM NAME FLOOR AREA Open Office 215 3,168 NOTE: Provide one copy of this form for each mechanical system when using the Prescriptive Approach. !SIZING AND EQUIPMENT SELECTION 1. DESIGN CONDITIONS: • OUTDOOR DRY BULB TEMPERATURE -OUTDOOR WET BULB TEMPERATURE • INDOOR, DRY BULB TEMPERATURE 2. SIZING: • DESIGN OUTDOOR AIR -ROOM LOADS • RETURN VENTED LIGHTING • RETURN AIR DUCTS -RETURN FAN -SUPPLYFAN • SUPPLY DUCTS (APPENDIX C) (APPENDIX C) SEE ASHRAE CHAPTER 8, 1993 OR APPENDIX B 4751 CFM (MECH 3; COLUMN I) ~---~ TOTALS SAFETY/WARM-UP FACTOR MAXIMUM ADJUSTED LOAD (TOTALS FROM ABOVE x SAFETY/ WARM-UP FACTOR) 3. SELECTION: INSTALLED EQUIPMENT CAPACITY (ADJUSTED FOR DESIGN CONDITIONS) IF INSTALLED CAPACITY EXCEEDS MAXIMUM ADJUSTED LOAD, EXPLAIN FAN POWER CONSUMPTION 0 [fil ~ [[] [I] DESIGN EFFICIENCY NUMBER FAN DESCRIPTION BRAKE HP MOTOR DRIVE OF FANS Supply Fan 1.000 82.5% 100.0% 2 COOLING 83°F 68°F 74°F 3 673 71,779 0 3,589 0 0 3,589 82,6291 1.21 99,982 72,8731 Btu/ Hr IT] PEAK WATTS BxEx746/(CXD 1,808 NOTE: Include only fan systems exceeding 25 HP (see Section 144). TOTALS I 1,8081 I Total Fan System Power Demand may not exceed 0.8 Watts/cfm for TOTAL FAN SYSTEM I constant volume systems or 1.25 Watts/cfm for VAV systems. POWER DEMAND WATTS/CFM EnergyPro 2.1 By EnergySoft User Number 3429 Job Number: HEATING 34°F 18.207 40 139 n/a 2,007 0 0 2,007 62,3611 1.43 89,176 87,3341 Btu/ Hr @] CFM (Supply Fans) 4,000 4,oool 0.4521 Col. F /Col. G Page: 17 of 20 !MECHANICAL SIZING AND FAN POWER MECH-41 PROJECT NAME DATE Abtech Svstems 06/29/2000 SYSTEM NAME FLOOR AREA Office 216 165 NOTE: Provide one copy of this form for each mechanical system when using the Prescriptive Approach. !SIZING AND EQUIPMENT SELECTION 1. DESIGN CONDITIONS: -OUTDOOR DRY BULB TEMPERATURE -OUTDOOR WET BULB TEMPERATURE -INDOOR, DRY BULB TEMPERATURE 2. SIZING: -DESIGN OUTDOOR AIR -ROOM LOADS -RETURN VENTED LIGHTING -RETURN AIR DUCTS -RETURN FAN -SUPPLYFAN -SUPPLY DUCTS (APPENDIX C) (APPENDIX C) SEE ASHRAE CHAPTER 8, 1993 OR APPENDIX B 251 CFM (MECH 3; COLUMN I) '------~ TOTALS SAFETY/ WARM-UP FACTOR MAXIMUM ADJUSTED LOAD (TOTALS FROM ABOVE x SAFETY/ WARM-UP FACTOR) 3. SELECTION: INSTALLED EQUIPMENT CAPACITY (ADJUSTED FOR DESIGN CONDITIONS) IF INSTALLED CAPACITY EXCEEDS MAXIMUM ADJUSTED LOAD, EXPLAIN FAN POWER CONSUMPTION 0 [[] @] @] [[] DESIGN EFFICIENCY NUMBER FAN DESCRIPTION BRAKE HP MOTOR DRIVE OF FANS Supply Fan 0.250 77.0% 100.0% 1 COOLING 83°F 68°F 74°F 154 12,037 0 602 0 0 602 13,3981 1.21 16,211 15,0681 Btu/ Hr 0 PEAK WATTS BxEx746/(CXD 242 NOTE: Include only fan systems exceeding 25 HP (see Section 144). TOTALS I 24211 Total Fan System Power Demand may not exceed 0.8 Watts/cfm for TOTAL FAN SYSTEM I constant volume systems or 1.25 Watts/cfm for VAV systems. POWER DEMAND WATTS/CFM EnergyPro 2.1 By EnergySoft User Number 3429 Job Number: HEATING 34°F 949 5 77 n/a 289 0 0 289 7,2971 1.43 10,435 13,6361 Btu/ Hr @] CFM (Supply Fans) 600 6001 0.404/ Col. F / Col. G Page:18 of 20 !MECHANICAL MANDATORY MEASURES PROJECT NAME Abtech S stems DESCRIPTION Equipment and Systems Efficiencies D §111 Any appliance for which there is a California standard established in the Appliance Efficiency Regulations will comply with the applicable standard. D § 115(a) Fan type central furnaces shall not have a pilot light. D § 123 Piping, except that conveying fluids at temperatures between 60 and 105 degrees Fahrenheit, or within HVAC equipment, shall be insulated in accordance with Standards Section 123. D § 124 Air handling duct systems shall be installed and insulated in compliance with Sections 601,603 and 604 of the Uniform Mechanical Code. Controls § 122(e) Each space conditioning system shall be installed with one of the following: D § 122(e)1A Each space conditioning system serving building types such as offices and manufacturing facilities (and all others not explicitly exempt from the requirements of Section 112 (d)) shall be installed with an automatic time switch with an accessible manual override that allows operation of the system during off-hours for up to 4 hours. The time switch shall be capable of programming different schedules for weekdays and weekends; incorporate an automatic holiday "shut- off' feature that turns off all loads for at least 24 hours, then resumes the normally scheduled operation; and has program backup capabilities that prevent the loss of the device's program and time setting for at.least 10 hours if power is interrupted; or D § 122(e)1 B An occupancy sensor to control the operating period of the system; or D § 122(e)1 C A 4-hour timer that can be manually operated to control the operating period of the system. D § 122(e)2 Each space conditioning system shall be installed with controls that temporarily restart and temporarily operate the system as required to maintain a setback heating andlor a setup cooling thermostat setpoint. D § 122(g) Each space conditioning system serving multiple zones with a combined conditioned floor area more than 25,000 square feet shall be provided with isolation zones. Each zone: shall not exceed 25,000 square feet; shall be provided with isolation devices, such as valves or dampers, that allow the supply of heating or cooling to be setback or shut off independently of other isolation areas; and shall be controlled by a time control device as described above. D § 122(a&b) Each space conditioning system shall be controlled by an individual thermostat that responds to temperature within the zone. Where used to control heating, the control shall be adjustable down to 55 degrees F or lower. For cooling, the control shall be adjustable up to 85 degrees F or higher. Where used for both heating and cooling, the control shall be capable of providing a deadband of at least 5 degrees F within which the supply of heating and cooling is shut off or reduced to a minimum. D § 122(c) Thermostats shall have numeric setpoints in degrees Fahrenheit (F) and adjustable setpoint stops accessible only to authorized personnel. D § 112(b) Heat pumps shall be installed with controls to prevent electric resistance supplementary heater operation when the heating load can be met by the heat pump alone. EnergyPro 2.1 By EnergySoft User Number: 3429 Job Number: Part 1 of 2 MECH-MMI DATE 06/29/2000 Designer Enforcement Page: 19 of 20 " !MECHANICAL MANDATORY MEASURES Part 2 of 2 MECH-MM! PROJECT NAME DATE Abtech S stems 06/29/2000 Description Designer Enforcement Ventilation D § 121(e) Controls shall be provided to allow outside air dampers or devices to be operated at the ventilation rates as specified on these plans. D § 122(f) Gravity or automatic dampers interlocked and closed on fan shutdown shall be provided on the outside air intakes and discharges of all space conditioning and exhaust systems. D § 122(f) All gravity ventilating systems shall be provided with automatic or readily accessible manually operated dampers in all openings to the outside, except for combustion air openings. D § 121(f)1 Air Balancing: The system shall be balanced in accordance with the National Environmental Balancing Bureau (NEBB) Procedural Standards (1983), or Associated Air Balance Council (AABC) National Standards (1989); or D § 121(f)2 Outside Air Certification: The system shall provide the minimum outside air as shown on the mechanical drawings, and shall be measured and certified by the installing licensed C-20 mechanical contractor and certified by (1) the design mechanical engineer, (2) the installing licenced C-20 mechanical contractor, or (3) the person with overall responsibility for the design of the ventilation system; or D § 121(f)3 Outside Air Measurement: The system shall be equipped with a calibrated local or remote device capable of measuring the quantity of outside air on a continuous basis and displaying that quantity on a readily accessible display divice; or D § 121(f)4 Another method approved by the Commission. Service Water Heating Systems D § 113(b)2 If a circulating hot water system is installed, it shall have a control capable of automatically turning off the circulating pump(s) when hot water is not required. D § 113(b)3B Lavatories in restrooms of public facilities shall be equipped with controls to limit the outlet temperature to 110 degrees F. D § 113(b)3C Lavatories in restrooms of public facilities shall be equipped with one of the following: Outlet devices that limit the flow of hot water to a maximum of 0.5 gallons per minute. Foot actuated control valves, and outlet devices that limit the flow of hot water to a maximum of 0.75 gallons per minute. Proximity sensor actuated control valves, and outlet devices that limit the flow of hot water to a maximum of 0.75 gallons per minute. Self-closing valves, and outlet devices that limit the flow of hot water to a maximum of 2.5 gallons per minute, and 0.25 gallons/cycle (circulating system). Self-closing valves, and outlet devices that limit the flow of hot water to a maximum of 2.5 gallons per minute, and 0.50 gallons/cycle (non-circulating system). Self-closing valves, and outlet devices that limit the flow of hot water to a maximum of 2.5 gallons per minute, and 0. 75 gallons/cycle (foot switches and proximity sensor controls). EnergyPro 2.1 By EnergySoft User Number: 3429 Job Number: Page: 20 of 20 City of Carlsbad Bldg Inspection Request For: 9/5/2000 Permit# CB002486 Inspector Assignment: RB --- Title: ABTECH SYSTEMS Description: Tl -RECONFIGURE EXIST BUILDOUT Type:TI Job Address: Sub Type: COMM 2728 LOKER AV WEST Phone: 7604974559 Suite: Lot 0 Location: lnspe,ctor: APPLICANT AVENT LISA Owner: CARLSBAD CROSSROADS LTD Remarks: Total Time: CD 14 17 Description Frame/Steel/Bolting/Welding Interior Lath/Drywall Associated PCRs lnsRection Histor~ Date Description 8/28/2000 24 Roughffopout 8/24/2000 14 Frame/Steel/Bolting/Welding 8/24/2000 21 Underground/Under Floor 8/24/2000 34 Rough Electric Requested By: DAVID Entered By: ROBIN Act · Comments f..i_ i/avt.. olwc_ ~~ wr~~~ ft _______ ~ Act lnsp Comments AP RB co RB PA RB UNDR SLAB OK ONLY AP RB WALLS ONLY . i ~-; . . -· • ' • ~ l~Tl-::;-ON _ __,, IF REGO. - ,\ ~~-~ Gf1LIN6 '---,----'------_ ~ • GEILIN6 AS REGUIREt> . _,,---2 112• ~ 25 6A. METAL s11JDS A1 ~4• O.C. (20 6A 5TEEL ·sTIJDS AT EA SIDE OF DOOR OFEl>l,IN5), lc:.BO #4162 . ' _,.-,--,--, $/6" 6YF'. BO. T'r'PE "X' ,,---~ eD CONG-. NAILS AT 24' Ot:,. ON YiOOD R.OORS VilTH CONC. QR 4' -0' O.C. AT GONG. Fl,.OORS. : ----~Jijt~ ___ j6YP. T0PPIN5. USE SHOTPl~AT . =·,~ -*-.~,-' 1 ~~~-'-CD NON RATED INTERIOR PARTITION Ol'E LAYER $/8' ---·• 6l'P.60.E,A..51DE .·~r-\~4'.-.~ ---t . • I ; I -'./ I i . ·, q . ·' ,.., h •.'. '! . ·, :;-c ,._ ' ... ,. . ,i .. .. ' .•· r====-=. ;:fit' \==.-,,-==, . , I-? t', ' 1'i"c\ PARTITION AT WINDOW MULLION ,.. , . .• / Y'!ALL PAA.T!TION . ~FLOOR PLAN ·,•-. ... • ... . ·-: ~ '' :_:_·.::, i::1· ·1--~---TOP-rR.Ac.k P-'-"L.....--.--=·"LCJ AT 1'00R HEAi:' ,. .. f .• ,. . . ,. .. •· .. . _c: .•. .... . ~-,--,I-~~'-HOLLO~METAL __ ,,,/~-.-,.1-~ DOOR FRAME WITH STUD ANCHORS 0 HEAD ® JAMB 01---D_OO_R_D_E_TA-,"--'-I L-· ____ , SJF'PORT FIXT1JR!!5 OVER. 56 LB5. K/4 l~ENT T.AJ.it 12 GA. v,IIRES -A1TAC-l--feD TO ;IT'FWC,T\IFU; ~. ~I~ H.15T Bf: C.APA61J: Of 5UPPORTIN6-4 ilMES YiEliSHT Of THE FIXTURE. I . i . . 5USPl!NCB> GEILIN6 SYSTEM ----.,__ ~ . d ~ I I 7 .._ SUPPORT FIXT'L,IR.ES ,iEl6HTIN6 LESS n-tAN 56 POUNDS 1112 SLACK 12 6A. 5ArfT'r" YilRe ODIM. CORNERS. @BRACING @ 2 X 4 LIGHT FIXTURE ) . . MET. s'lW COMPRESSION STRUT '121 o'.f;,. l:A. P!RfGTION f. 6' MAX FROM YiALLS. ~~-SPLAY 1'11ftES 12 ~A, f'l'P. ;~;l~TI~- ~ Df6Rl:f MAX. FROM Cl-6. PLANE. 00 DE6REE MAX FROM EAG!-1 OT1-ER AND 121-0' O.C. EA. DIREC-OON. ·. I (;R.055 TEE I AT24"0.C. ~ 1 :fP' I , /2 I I ~ T I I I I / ~ ,~ ~ . \ ·5 . ~· .· . . . . 1/ "' --I ··.·.··.~··· ... ··. ~· ~~·.:. r.··.· .. ·· •----:,,__!~~ . MAIN TEE OR MAIN ... (J• _ · --_ ~< · _ ---- ~ 4'-0" O.G. TYf'. _ Yi-_ ,,,... ~ -_ -. ·. _ ,, 1 -,.. ~ . . . 'i . . ~ . . . NOTE.-. ·cF<.OSS 1'EE .-:2'><2' ACGOIJ5TIGAL CEILING TYP. LATERAJ.. FORCE BRAC1N6 MEMBERS SH.AU. BE SPACED i,., MINIMJM OF 6" FROM AU. HORIZONTAL PIPINo5 D!Jc.T ~ "THAT 15 NOT F'ROVIDED i"IITH ~JN& ~7RANT$ i=oR HORIZON\" AL ~-BRAGl"5 Vil~ sHALL 6f A Tl' ACHED TO -n-lE 6R!D AND TO TiiE S~T\,IRE IN SUC,H A MANNER iHAT 'THEY CAN SUPPORT A OES!iSN l-OAP Of NOT LE55 TH,AN 200 · POl..lNOS OR 1l£ AGTUAl LOAD, Y+llc+EVER 15 6REA~ ~ITH --A SAFETY FACTOR OF .2, .45 PE6REE Sf'LAy rtlli:ES 4 i'\ooi5 IN~ 11/.2', T'(P. . '-~ 1 · . .-J l · 2' MAX. FROM INTERSECTION (STRIJT ------~ :2' MAX. FROM SPLAY JlilRES). ® SUSPENDED CEILING -, • PROVIDE Yt?Ob BI..OGK.IN6 ~ /~~ Y(ALL IS PERLIN TO ROOf:: -. _ ~ _., ~~~=-~=-~~rFe -'-''i'r.l/:~=~==·=·:EX=:15T. ROOF S1=ME · , \ , . . • ·-\ \ • • ' . b . ' ·b -i.u x 5 ii El I u " I "' ~ ~ SO){[)' · a_ INSU!..ATl-ON _ _,,- lf ~. . i, ' ~ ' ' - ~ -.~ y ' L '---. SHOT PINS @ e'O• 0.G. IGBO t6set -:---,-6RACe5 AT &'-0' O.G-. MAX, -----~ OF_6YP. 60. .2 1/2" -25 IS.Ai. METAL S'TUOS AT :24" O.G-. '(20 6A. STEEL 511JD5 AT EA. SIDE Of DOOR Of'ENIN6). IC.BO ce206P fiD c.oNC.. NA!~ AT 24' di. ON i'l'>OD FLOORS ~ITH CON<:. OR 6'r"P. TOPP!NiS. U5E SHOT PINS AT 4' -"O' 0£. ,.._T GONC. fl,..OOR5. IGBO # /6S<t · . .. • @si--··· 1--N~O_N_R_AT_E_D_I N,--"-T_ER_IO_R_· P_A_RT_ITI ON ·.~ .. ' • . ' ~ -~. eoTtO!< OF 51=ME. ·. ·.· _.--,-EXTENr OF 6YP. Bo. ----"• =====al'.8~'~:;:===;== ~~a 5/0' -25 6A. METAi. STUDS AT . el 50UNI) o. IN~l,An;ON:::-:::REGC>=.__,,, • • , _ _.,, . 1(1" o.c.. , ::i J/2i -2S iSA METAL STUDS AT · -- 24' O.'-.. (20 iSA. STfEi.. STUD$ AT EA. SIDE OF DOOR OFEJ-IIN6). ICSO 11-8206 P ___.-----5/e" 6YP. eo. TYPE •x• ,,-----er, GCNC. NAILS AT .:W O.C. OH · YiOOP fl..OORS ¥(In! catt:.. OR 6YP, TOFPIN6. USc SHoT PINS AT 4' ..O" OC. AT CONG-. FLOOR.$, 1cea • lbS't ® INTERIOR PARTITION @ HARDLID -~. --·-. . _,:' .· i' • t3 ' --' . I, . i . ··:. ~--: .. :.. .;. •, -~ ' j ; "' D , a! w . . w ~ __ ; -~ ,_v,·· --.. ' • I .... ,_ · · · PROV'1DE YiOOD eLOGK1NiS lff:Rf /'.~. _¥tA.U.ISPER!..INTOROOF •. -. ==='===ir./F"si~;'=. =._=EX==;IST. ROOF,,-m,e .•.. ·.· ... ·· --20 iSA. CONT. 511,. TOP ATTAfl. _ _,,/ -·, YV #l2X l/14'L.6.'5GREY6 0 24" ,.,,.__., 0.C. . . -, ' . . \ .6. DEMISING PARTITION ,. i' . I' t } _,-.. :_ ... ;_·:' '. ;, •• ' . ._,,/ ACOJ5T!CAL GEIL.lt-16 -~ 9-IOViN ON PL.ANS - DIAiSONA1..JHOR1ZONTN... BRAc.1N5 "-.._~-.. 9 51f;• -::ZS 6A. LAYCVf BRACE \ . --IN OF'P051N6 POSITONS, GONNEGT . · TO~IGULAR.rw..l.FOR - !ffi'ORT . ~ RM. l:2CI ... OOLJeL.e:- 6RiAic,1Ni:S-REGIUIRED -(:2) S Slf!J' ,. 25 GoA: GCNNEG,T TO l:XTERIOR l'IALL FOR SlffORT .,,,.--.-2 1/2~ -~ GA. METAL STIJOS AT 24' O.G-. ·(20 6A.· STEEL 5'1V05 AT EA. SIDE OF DOOR OPENING-) •. · ICSO IS206 P -· _;,.--~--_ s;e• i5YP. oo. 1YPI: ·x· ,,-----&D CONC. NAILS A"t .:!4" d.G. oN l'lOOD FLOORS ~Ill! CONG. OR 6'r'P. TOPPIN6. IJ3E _Sl-br PINS AT 4' -0' OC. AT CONG. F'LOORS. IGBO # 165GI -. . ' .' .-. ' '( . ,...., ~ •.. ~. -"-"-~-__JILScf==ll.__-----' .. \ '• ~. ' . ',. , ........ -. . . -------· -·'. FINISH SCHEDULE _:,-~:--~-·· ~'·'·. '-~ .,_ .... , .' : ·• ·. , . ., _j \" _:, 760.740.013::5 (F) 760.740.0161 ROOM ROOM FLOOR WALLS -.· CEILING NOTES NAME NO. N ·· ·. E S W TYPE HT, BREAK RM.·· 106 VCTl,2 RB P P P P ACT STORAGE 112 CONC, RB P P P P ACT II COMP, RM, 116 VCT1,2 RB P P P P ACT H,C, TOILET 117 sv sv p P p p GB AVENT H,C, tOILET 118 sv sv p p p p GB DESIGN f--BR_Ec_A_K_· _R_M_, _____ -----<_1_2_6---'-ll-'-V_CT~1--'-,e-2f-.-RB_-+---'--P-,-+_· --'-P-+-_P--I_P-+_AC..;_T-+---+------',.-~-----'--r----1 SPACE PLANNING INTERIOR DESIGN KITCHEN .127 VCT1 ,2 RB P •· P . P P ACT LISA AVENT 1413 U,.OYD PLACE • ESCONDIDO, CALIFORNIA 92027 SECURED STORAGE· 132 VCT RB P P. P P ACT STORAGE · 134 CONC, RB P P P . P ACT H.C. TOILET.. 213 .· sv sv P P .. P ·. P GB ISSUE 1---~----------+---+---+---+----l---+--'----+--+--"'=---+----+-----------r-'-'----,---..J NO. . DATE DESCRIPTION f-,-'H....,., C---T~O=I I =ET~----+-=-2 ~1 4'-+_s_v ---f----'sc...;..v~f-,-·· _P_· !-,-.· -'--P~.· t--,. ·_P-.-+-~p -+--G--'--8--+--+---,--__,._-------r----1 ff.. ~ -I , ~!/;:, 'l-e)I, STORAGE 217 VCT RB P P P p AClf ' ' . ' . ' ' . NOTE: ·. ALL OTHER AREAS NOT NOTED. ABOVE TO BE RECARPETEO WITH NEW BASE, AND PAINT AT NEW WALLS,· EXCEPT WAREHOUSE 130, WORK RM, 129, AND CLOSET 128 TO BE EXISTING CONCRETE, NOTE:· -. EXISTING CEILING HEIGHT IS. ABOVE 8'0''. TYPICAL -CONTRACTOR· TO MATCH EXISTING, CP sv p CARPET · SHEET VINYL WITH INTERGRATED COVE· · · .. PAINT ;_ MATCH EXISITNG TEXTURE TOILETS-SEMIGLOSS . OFFICE -t:GGSHELL ACT GB RB ACOUSTICAL· CEILING. TILE MATCH EXISTING GYPSUM BOARD CEILING BASE DOOR SCHEDULE DOOR• NO, E El A D F G H J K L M ' " DOOR SIZE DOOR w H T TYPE MTL FIN 3'0" EXISTING DOOR TO R~MAIN FRAME MTL FIN HARDWARE 'GROUP FIRE RATING NOTES .~'n" EXISTING DOOR TO REMAI.N -. DOOR· HARDWARE TO BE REVISED TO · LOCKSET • 3'0" EXIST,DOOR-REPLACE · WITH STEEL DOOR HW-2 · 3'0" MATCH EXISTING DOOR 3'0'1 MATCH EXISTING DOOR HW-1. .. 3'0" MATCH EXISTING DOOR HW-,-2 3'0" MATCH EXISTING DOOR STEEL DOOR 3'0" MATCH EXISTING DOOR HW-1 20 · MIN, . 3'0" EXISTING· DOOR TO BE RELOCATED HW~2 6'0" MATCH. EXISTING DOOR HW~2 6'0" · MATCH EXISTING DOOR HW-1 3'0" MATCH EXISTING. DOOR HW'-2 1 PIECE FRAME WITH 3' · SIDELIGHT .. 3'0" MATCH EXISTING DOOR HW-1 1 PIECE FRAME WITH 3' SIDELIGHT EXISTING DOOR TO BE REMOVED AND REPLACED WITH 6'0" DOUBLE DOOR -MATCH EXISTNG_ EXISTING DOOR TO BE. REPLACED WITH A STEEL FIRE· DOOR WITH ALARMED PANIC HARDWARE · ·1,, DAtE -=MA~Y~22~. =20=do~-- PROJECt NO, __ 20_00_-_60_1 __ _ bRAWN BY -~L-~A=VE~NT-,,...c __ _ CLl~NT APP:-~-~--------- 1-----~-t-'-.,..--+--+----+--+---+--+------+--1-------+~-'----'--l--------------,---..J CLIENT APP. DATE:--~---- NOTES: . -. . ' ' 1. . DOORS TO BE BUILDING STANDARD. MATCH EXISTING, -· :· .---, 2, ALL FRAMES TO BE BUILDING STANDARD, MATCH EXISTING ' . . 3. DOOR HARDWARE TO BE LEVER HANDLE; MATCH EXISTING 4, DOORS TO. BE A MINIMUM OF 3'0" X 6'8" . HW'-1 LEVER HANDLE LATCHSET · WALL STbP HINGES HW-2 .. · · . LtliER HANDLE LOCKSET · WALL STOP • HINGES . HW-3 LEVER HANDLE PRIVACY LOCKSET WALL STOP HINGES : •CALIFORNIA COUNCIL FOR~ ' .... .... --~ ~ : u ,~ -.~ c ,1 nc: ... •' ·---l : ~ 2 ~ ( U'\VVZ.,, .. (}, I - Q ---= LISA 8 ,O\iE\f: '.;: GEiH1F•L,.tn·dfi-l11)R DESIGNER ;;" :!; 291 4 f_l.'PIR[S ()2_-02-02 :- " ! 110~ llJNOOJ 'rlNl!OHHJ1 ~ DETAILS/SCHEDULES Tl-8