Loading...
HomeMy WebLinkAbout2728 LOKER AVE W; ; CB003154; Permit) );f\O<j{\V City of Carlsbad 10/16/2000 1635 Faraday Av Carlsbad, CA 92008 Commercial/Industrial Permit Permit No: CB003154 Job Address: Permit Type: Parcel No: Valuation: Occupancy Group: Project Title: 10/16/2000 Applicant: Building Inspection Request Line (760) 602-2725 2728 LOKER AV WEST CBAD Tl Sub Type: 2090813000 Lot#: $45,000.00 Construction Type: Reference #: ABTECH SYSTEMS-INSTALL SPRAY COMM 0 NEW BOOTH-MOVED FROM 2777 LOKER AV WEST Owner: Status: Applied: Entered By: Issued: Inspect Area: ISSUED 08/28/2000 JM Plan Approved: 10/16/2000 LIEN RICL MOTION PICTURE INDUST~'6J~DJ!~@:Y~g -4,{§@..P~J;JT RJ.f.N PO BOX920 POWAY CA 92075 619-339-7425 Total Fees: Building Permit $662.82 Add'! Building Permit Fee Plan Check Add'! Plan Check Fee Plan Check Discount Strong Motion Fee Park Fee LFM Fee Bridge Fee BTD #2 Fee BTD #3 Fee Renewal Fee Add'! Renewal Fee Other Building Fee Pot. Water Con. Fee Meter Size Add'! Pot. Water Con. Fee Reel. Water Con. Fee C/O MCMORGAN & COMPANY C-PRNT 421~ 78 ONE BUSH ST SAN FRANCISCO, CA 94104 Total Payments To Date: $241.04 Balance Due: $421.78 $370.83 Meter Size $0.00 Add'I Reel. Water Con. Fee $0.00 $241.04 Meter Fee $0.00 $0.00 SDCWAFee $0.00 $0.00 CFO Payoff Fee $0.00 $9.45 PFF $0.00 $0.00 PFF (CFD Fund) $0.00 $0.00 License Tax $0.00 $0.00 License Tax (CFO Fund) $0.00 $0.00 Traffic Impact Fee $0.00 $0.00 Traffic Impact (CFO Fund) $0.00 $0.00 LFMZ Transportation Fee $0.00 $0.00 PLUMBING TOTAL $0.00 $0.00 ELECTRICAL TOTAL $20.00 $0.00 MECHANICAL TOTAL $21.50 Master Drainage Fee: $0.00 $0.00 Sewer Fee: $0.00 $0.00 Redev Parking Fee: $0.00 TOTAL PERMIT FEES $662.82 FINAL APPROVAL Date: /{/4/4:z, Clearance: _____ _ NOTICE: Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capactiy changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which ou have reviousl been iven a NOTICE similar to this, or as to which the statute of limitations has reviousl otherwise ex ired. V(O-f2/o PERMIT APPLICATION CITY OF CARLSBAD BUILDING DEPARTMENT 1635 Faraday Ave., Carlsbad, CA 92008 FOR OFFICE USE ONLY,~ PLAN CHECK N°'.JC..t;I _) 3/S.C( EST. VAL. -i J DUD Plan Ck. Deposit / :Zf/4df ~:~:_at-ed_s_v==\,-.,.:u_tJ\.___,""-:~~-i:t-t-L;,--Bc:· -6_FZJ-_ -_ Address {include Bldg/Suite #} Business Name (at this address) Legal Description Lot No. Total # of units _-~ ·241=04 Name Address City State/Zip Telephone # Fax# '3. -APPLICANT ... 0 Contractor . Rt~ L/ai .... ~~en;;;~nt~~:n·owrier .• n Ag?Yi ;;;;;' V --·~.-' Name Address City State/Zip Telephone# Name Address City S.tate/Zip Telephone# :s; ··-¢orJ'ijtACTQR',; C9JVil;'4NY-NArvi(" . (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law (Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code) or that he is exempt therefrom, and the basis for the alleged exez:tio~Any violation of Section 7031.5 by ;;Ya~ a,f;r/2-bb~ecJ'~;;Jtct)}r a f-b~;J7;t not mW than fve h ~d d 117 [ 500)). 1/ b Name Address City State/Zip Te ephone # State License # 0 7 7 b-o] License Class__________ City Business License # _______ _ Designer Name Address City State/Zip Telephone State License # _________ _ · 6~' -. WOF{K~Rs_t' cOMP~N,SATJ6N _ -y , 1 ,., --,~" ~ers' Compensation Declaration: I hereby affirm under penalty of perjury one of the following declarations: /0 lf,l_ I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance '-7f work for which this permit is issued. ~ I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is -JI' issued. My worker's compensation insurance carrie and licy mb rare· . &t?A~~ . . ~ b Insurance Company ,..,,-,_....-,.., M Policy No-:-~.,.~"'-,,,_,,,""~-'~~<+-=--¥=c,,.'P"-'~"----Exp1rat1on Dat~~~-'-''----'7,;.....,~~~- (Tf-\JS'SECTION NEED NOT BE COM LETED IF THE PERMIT IS FO ONE HUNDRED DOLLARS ($100) OR LESS) IE(' CERTIFICATE OF EXEMPTION: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Co pensation Laws of California. WARNING: Failure to e ure work s' ·compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars ($1 , in addi io to the cost of compensation, damages as provided for in Section 3706 of the Lab r cod , interest and attorney's fees. SIGNATURE. __ -6,.-L---€:::::,,~-=--->.c,,...---------:--------DATE /0 fh !)/? -7,;._ .OWNEfl-Blm:.oER DECLARATION : . . . •,."' : I hereby affirm that I am exempt from the Contractor's License Law for the following reason: D I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). D I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). D I am exempt under Section ______ Business and Professions Code for this reason: 1. I personally plan to provide the major labor and materials for construction of the proposed property improvement. D YES ONO 2. I (have / have not) signed an application for a building permit for the proposed work. 3. I have contracted _with the following person (firm) to provide the proposed construction (include name / address / phone number / contractors license number): 4. I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone number/ contractors license number):. _____________________________________________ _ 5. I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone number / type of work):. _______________________________________________________ _ PROPERTY OWNER SIGNATURE _____________________ _ DATE ________ _ c'oivlP,fi.T.~THIS S~CTION·FQR NON-RESID.ENTtAi.BUll:,DiNG PERMIT$ ON~Y ,_· Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? 0 YES O NO Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? 0 YES D NO Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? 0 YES D NO IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. ~g;~~:)iofa~TR.li<{TiQN L'.e:Nbl_NG :AGENCY . . ~·=· . --~ .. .... '" : ..... ... ... ., . . ·. ~. I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097(i) Civil Code). LENDER'S NAME______________ LENDER'S ADDRESS ________________________ _ ·~,., A,PPLICAl'ff Cl;RTlf,ICAllQN . ... ... .... . .. .. ... -.. --·-·-.· ._. ....... _ -·· . : ,, ........ . I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all City ordinances and State laws relating to building construction. I hereby authorize representatives of the Cit~ of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: An OSHA permit is required for excavations over 5'0" deep and demolition or construction of structures over 3 stories in height. EXPIRATION: Every permit issued by th building Official der the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenc within 180 d s rom the date of such permit or if the building or work authorized by such rmit i suspended or abandoned at any time after the work is comma ed for period of 80 ays (Section 106.4.4 Uniform Building Code). WHITE: File YELLOW: Applicant PINK: Finance City of Carlsbad Bldg Inspection Request For: 1 0/27 /2000 Permit# CB003154 Title: ABTECH SYSTEMS-INSTALL SPRAY Description: BOOTH-MOVED FROM 2777 LOKER AV WEST Type:TI Job Address: Suite: Location: Sub Type: COMM 2728 LOKER AV WEST Lot O APPLICANT LIEN RICL Owner: CARLSBAD CROSSROADS LTD Remarks: SPRAY BOOTH INSP Total Time: CD . Description Act Comments Inspector Assignment: TP --- Phone: 8587487446 Inspector: __e_ Requested By: JESSICA Entered By: ROBIN 14 Frame/Steel/Bolting/Welding £ ____________________ _ ~------~~-----------.!f!i_ A/) Associated PCRs lnsQection Histoiy Date Description Act lnsp Comments 10/23/2000 11 Ftg/Foundation/Piers NS TP 10/23/2000 11 Ftg/Foundation/Piers WC TP 10/23/2000 44 Rough/Ducts/Dampers AP TP SPRAY BOOTH EXHST DUCT@ROOF EsGil Corporation In Partnership with Government for Building Safety DATE: 10/6/00 JURISDICTION: City of Carlsbad PLAN CHECK NO.: 00-3154 )-_7rJ_p PROJECT ADDRESS: '1IPF/ Loker Ave West SET: III PROJECT NAME: ABtech Systems-Spray Booth CJ APP~NT <!;(JURIS. CJ PLAN REVIEWER .CJ FILE D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. [2s] The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified in the remarks below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. D The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. D The applicant's copy of the check list has been sent to: [2s] Esgil Corporation staff did not advise the applicant that the plan check has been completed. D Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Telephone#: Date contacted: (by: ) Fax #: Mail Telephone Fax In Person [2s] REMARKS: Building Inspector to verify adequate fixed openings to provide make-up air for spray booth ( applicant indicted louvered skylights ) · By: Doug Moody Esgil Corporation D GA D MB D EJ D PC Enclosures: 9/29/00 trnsmtl.dot 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858) 560-1468 + Fax (858) 560-1576 EsGil Corporation In Partnership with Government for Building Safety DATE: 9/7 /00 JURISDICTION: City of Carlsbad PLAN CHECK NO.: 00-3154 SET:I PROJECT ADDRESS: 2777 Loker Ave West PROJECT NAME: Spray Booth -ABtech Systems D~NT ~ D PLAN REVIEWER D FILE D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. D The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. ~ The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. ·o The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. ~ The applicant's copy of the check list has been sent to: Rick Lien P.O. Box 920, Poway, Ca. 9ZCJlJJ'i D Esgil Corporation staff did not advise the applicant that the plan check has been completed. ~ Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Rick Lien (.1-~) Telephone#: 619-339-7425 Date contacted:"1 /~f oo (by:~ ) Fax #: Mail 0elephonev"' Fax In Person D REMARKS: By: Doug Moody Esgil Corporation D GA D MB D EJ D PC Enclosures: 8/29/00 tmsmtl.dot 9320 Chesapeake Drive, Suite 208 + San Diego, Califoi:n,ia 92123 + (858) 560-1468 + Fax (858) 560-1576 City of Carlsbad 00-3154 9/7/00 PLAN REVIEW CORRECTION LIST TENANT IMPROVEMENTS PLAN CHECK NO.: 00-3154 OCCUPANCY: B /F2 TYPE OF CONSTRUCTION: VN ALLOWABLE FLOOR AREA: SPRINKLERS?: YES REMARKS: 8/28/00 DATE PLANS RECEIVED BY JURISDICTION: DATE INITIAL PLAN REVIEW COMPLETED: 9/7/00 FOREWORD (PLEASE READ): JURISDICTION: City of Carlsbad USE: Painting Computer Parts ACTUAL AREA: 140 STORIES: HEIGHT: OCCUPANT LOAD: N/A DATE PLANS RECEIVED BY ESGIL CORPORATION: 8/29/00 PLAN REVIEWER: Doug Moody This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Departmen_t, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a.building permit. Code sections cited are based on the 1997 UBC. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet number, specification section, etc. Be sure to enclose the marked up Ust whe~ you submit the revised plans. TENANT IMPROVEMENTS WITHOUT SPECIFIC ENERGY DATA OR POLICY SUPPLEMENTS (1997UBC) tifoiw.dot City of Carlsbad 00-3154 9/7/00 Please make all corrections on the original tracings, as requested in the correction list. Submit three sets of plans for commercial/industrial projects (two sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. 1. Each sheet of the plans must be signed by the person responsible for their preparation, even though there are no structural changes. Business and Profe$sions Code. 2. Provide a statement on the Title Sheet of the plans stating that this project shall comply with the 1998 edition of the California Building Code (Title 24), which adopts the 1997 UBG, UMC and UPC and the 1996 NEC. 3. Indicate the use of all spaces adjacent to the area being remodeled or improved. 4. Please provide evidence of Fire Department approval. 5. A complete description of the activities and processes that will occur in this tenant space should be provided. A listing of all hazardous materials should be included. The materials listing should be stated in a form that would make classification in Tables 3-D and 3-E possible. The building official may require a technical report to identify and develop methods of protection from hazardous materials. Section 307.1.6 .. a) Provide data on proposed hazardous material to be stored and used. USC, Section 307 and UFC. b) Clearly show the types of hazardous material that are being stored or used, as per the USC, Table 3-D and 3-E classifications. Provide the material safety data sheets (MSDS). c) Clearly show the amounts of each type of hazardous material to be stored and in use. d) Clearly show where in the buildings each type of hazardous material is being stored or used. City of Carlsbad 00-3154 9/7/00 e) Provide calculations for required containment in each area of-the buildings, as per UBC, 307.2.5. f) Provide a written response to show how Spill Control and Drainage are being handled as required in UBC, Sections 307.2.3 & 307.2.4. g) Provide the required manual shutoff control for ventilation equipment as per UBC, Section 1202.2.3. 7. Provide the listing data and installation data for the spray booth. If not listed a third party installation report will be required for the approval of the construction and installation of the proposed rooms and station to approved standards. UMC, Section 302.2 8. On the plan show the use of all the spaces within the building where the work is to be done. Show the location of the proposed spray booth. 9. Detail on the plans the construction of the roof framing head outs for the equipment duct penetrations. 1 O. Detail exhaust ventilation system compliance with UMC Chapters 5 & 6. a) Detail the required make-up air as per UMC, Section 505.6. b) Detail the exhaust outlet clearances as perUMC, Sections 504.6 & 505.9. c) d) e) f) g) h) i) j) Clearly show the duct materials are suitable for the intended use. UMC, Section 609 .1 · Clearly show the exhaust duct material and gage used for each duct size. See UMC, Table 5-B & 5-C. . Detail ducts conveying explosives or flammable vapors, fumes or dusts shall extend directly to the exterior of the building without entering other spaces. UMC, Section 505.1. Detail· minimum duct conveying velocities as per UMC, Section 505.4 and Table 5-A. Detail duct support as per UMC, Section 609.6. Detail fire protection as per UMC, Section 609.7. Detail clearances from combustibles as per UMC, Sections 609.8 & 609.8.1. Detail protection from physical damage as per UMC, Section 609.9. 11. Please provide an equipment schedule for the exhaust and make-up air equipment. 12. Please provide a panel schedule, indicate on the schedule new and existing loads, indicate on the plans the location of the panel. City of Carlsbad 00-3154 9/7/00 13. Please note or show on the plans the wiring shall comply with Section 516 of the 1996 NEC. To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please indicate: Yes CJ No CJ The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Doug Moody at Esgil Corporation.· Thank you. City of Carlsbad 00-3154 9/7/00 VALUATION AND PLAN CHECK FEE JURISDICTION: City of Carlsbad PREPARED BY: Doug Moody BUILDING ADDRESS: 2777 Loker A,ve West PLAN CHECK NO.: 00-3154 DATE: 9/7 /00 BUILDING OCCUPANCY: B/F2 TYPE OF CONSTRUCTION: VN BUILDING AREA Valuation Reg. PORTION (Sq.Ft.) Multiplier Mod. Spray Booth 140 Citv aluation Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code cb By Ordinance I 1994 USC Building Permit Fee ... 1 / 1994 USC Plan Check Fee Type of Review: D Repetitive Fee [ERepeats Comments: 0 Complete Review Oother D Hourly Esgil Plan Review Fee VALUE ($) 45,000 45,000 45,000 I 370.831 241.041 D Structural Only 192.831 Sheet 1 of 1 macvalue.doc ' ' EsGil Corporation q/18l<X> DATE: 9/'f/60 In Partnership with Government for Building Safety JURISDICTION: City of Carlsbad PLAN CHECK NO.: 00-3154 SET:Jt PROJECT ADDRESS: 2777 Loker Ave West PROJECT NAME: Spray Booth -ABtech Systems D APPLICANT ~ D~EVIEWER D FILE D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. D The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. ~ The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. ~ The applicant's copy of the check list has been sent to: Rick Lien P.O. Box 920, Poway, Ca. C/ZoCt,'4 D Esgil Corporation staff did not advise the applicant that the plan check has been completed. i:;gj Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Rick Lien (",HJ Telephone#: 619-339-7425 Date contacted: i { 1 J'foe(by: ~) Fax #: Mail v Telephone v" Fax In Person D REMARKS: By: Doug Moody Esg ii Corporation D GA D MB D EJ D PC Enclosures: 8/29/00 trnsmtl.dot 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858) 560-1468 + Fax (858) 560-1576 City of Carlsbad 00-3154 9/7/00 PLAN REVIEW CORRECTION LIST TENANT IMPROVEMENTS PLAN CHECK NO.: 00-3154 OCCUPANCY: B /F2 TYPE OF CONSTRUCTION: VN ALLOWABLE FLOOR AREA: SPRINKLERS?: YES REMARKS: 8/28/00 DATE PLANS RECEIVED BY JURISDICTION: DATE INITIAL PLAN REVIEW COMPLETED: 9/7/00 FOREWORD (PLEASE READ): JURISDICTION: City of Carlsbad USE: Painting Computer Parts ACTUAL AREA: 140 STORIES: HEIGHT: OCCUPANT LOAD: N/A DATE PLANS RECEIVED BY ESGIL CORPORATION: 8/29/00 PLAN REVIEWER: Doug Moody This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Code sections cited are based on the 1997 UBC. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. .Per Sec. 106.4.3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet number, specification section, etc. Be sure to enclose the marked up list when_you submit the revised plans. TENANT IMPROVEMENTS WITHOUT SPECIFIC ENERGY DATA OR POLICY SUPPLEMENTS (1997UBC) tifoiw.dot City of Carlsbad 00-3154 9/7/00 Please make all corrections on the original tracings, as requested in the correction list. Submit three sets of plans for commercial/industrial projects (two sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. The correction listed below was determined to be applicable to the proposed spray booth installation. These remaining corrections are the result of examination of the proposed plans and meeting between Mr. Culver, Mr. Mendenhall, Mr. Wilczak and myself. 1. Each sheet of the plans must be signed by the person responsible for their preparation, even though there are no structural changes. Business and Professions Code. 2. Provide a statement on the Title Sheet of the plans stating that this project shall comply with the 1998 edition of the California Building Code (Title 24), which adopts the 1997 UBC, UMC and UPC and the 1996 NEC. 3. Indicate the use of all spaces adjacent to the spray booth. Please indicate the occupancy of the adjoining areas to determine if an occupancy separation is required. 4. Please provide evidence of Fire Department approval. 5. A complete description of the activities and processes that will occur in this tenant space should be provided. A listing of all hazardous materials should be included. The materials listing should be stated in a form that would make classification in Tables 3-D and 3-E possible_. The building official may require a technical report to identify and develop methods of protection from hazardous materials. Section 307 .1.6 .. · City of Carlsbad 00-3154 9/7/00 a) Clearly show the types and amounts of hazardous material that are being stored or used, as per the UBC, Table 3-D and 3-E classifications. Provide the material safety data sheets (MSDS) . . b) Clearly show where in the buildings each type of hazardous material is being stored or used. When the quantities of hazardous materials require secondary containment please show compliance with the following: c) Provide calculations for required containment in each area of the buildings, as per UBC, 307.2.5. d) Provide a written response to show how Spill Control and Drainage are being handled as required in UBC, Sections 307.2.3 & 307.2.4. e) Provide the required manual shutoff control for ventilation equipment as per UBC, Section 1202.2.3. 7. Detail on the plans the construction of the roof framing head outs for the equipment duct penetrations. Per Section 106.3.3 8. Detail exhaust ventilation system compliance with UMC Chapters 5 & 6. a) Detail the required make-up air as per UMC, Section 505.6. b) Detail the exhaust outlet clearances as per UMC, Sections 504.6 & 505.9. . c) Detail ducts conveying explosives or flammable vapors, fumes or dusts shall extend directly to the exterior of the building without entering other spaces. UMC, Section 505.1. Please indicate clearly on the plans if a rated shaft is required to provide separation between the H2 spray booth and the adjacent occupancy. d) Detail minimum duct conveying velocities as per UMC, Section 505.4 and Table 5-A. e) Please indicate on the plans if the duct requires any change in direction to provide the required clearances from existing building structures or to provide the clearances per sections 504.6 and 505.9 If so please detail duct support as per UMC, Section 609.6. f) Detail fire protection as per UMC, Section 609.7. g) Detail clearances from combustibles as per UMC, Sections 609.8 & 609.8.1. If a rated shaft is required please detail the clearances and construction. h) Detail protection from physical damage as per UMC, Section 609.9. City of Carlsbad 00-3154 9/7/00 9. Please provide an equipment schedule for the exhaust and make-up air equipment. 10. Please provide a panel schedule, indicate on the schedule new and existing loads, indicate on the plans the location of the panel. 11. Please note or show on the plans the wiring shall complywith Section 516 of the 1996 NEC. To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please indicate: Yes D No D The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Doug Moody at Esgil Corporation. Thank you. DATE: to{q/ru BUILDING ADDRESS: PROJECT DESCRIPTION:~ft:-v/ ~ , ASSESSOR'S PARCEL NUMBER: _________ EST. VALUE: tf-~/(J'UV ENGINEERING DEPARTMENT APPROVAL The item you have submitted for review has been approved. The approval is based on plans, information and/or specifications provided in your submittal; therefore any changes to these items after this date, including field modifications, must be reviewed by this office to insure continued conformance with applicable codes. Please review carefully all comments attached, as failure to comply with instructions in this report can result in suspension of permit to build. CA Right-of-Way permit is required prior to construction of the following improvements: DENIAL Please s~ehe ttached report of deficiencies marked wi D. ke necessary corrections to plans or specifi · s for compliance with applicable codes and standar . Submit corrected plans and/or specifications to ffice for review. By: /C Date: By: ________ Date: By: Date: FOR OFFICIAL USE ONLY By: ~NEERING AUTHORIZATION TO ISSUE BUILDING PERMIT: ( _ 1 Date: IO (p 00 ... - ATTACHMENTS D Dedication Application D Dedication Checklist D Improvement Application D Improvement Checklist D Future Improvement Agreement D Grading Permit Application D Grading Submittal Checklist D Right-of-Way Permit Application D Right-of-Way Permit Submittal Checklist and Information Sheet ENGINEERING DEPT. CONTACT PERSON Name: KATHLEEN M. FARMER City of Carlsbad Address: 1635 Faraday Avenue, Carlsbad, CA 92008 Phone: (760) 602-2741 CFD INFORMATION Parcel Map No: Lots: Recordation: Carlsbad Tract: D Sewer Fee Information Sheet A-4 H:1woR011J.635K~if'11!!1!tf'a-9'em~~n011icJ.@arlsbad, CA 920081-7314 • (760) 602-2720 • FAX (760) 6021.8$@@ @ BUILDING PLANCHECK CHECKLIST SITE PLAN ~ ~ A ~wvtn 1. Pro_vide a fully dimensioned site plan drawn to scale. Show: A. North Arrow F. Right-of-Way Width & Adjacent Streets 8. Existing & Proposed Structures G. Driveway widths C. Existing Street Improvements H. Existing or proposed sewer lateral D. Property Lines I. Existing or proposed water service E. Easements J. Existing or proposed irrigation service D 2. Show on site plan: A. Drainage Patterns 1. Building pad surface drainage must maintain a minimum slope of one percent towards an adjoining street or an approved drainage course. 2. ADD THE FOLLOWING NOTE: "Finish grade will provide a minimum positive drainage of 2% to swale 5' away·from building." 8. Existing & Proposed Slopes and Topography .C. Size, type, location, alignment of existing or proposed sewer and water service (s) that serves the project. Each unit requires a separate service, however, second dwelling units and apartment complexes are an exception. D. Sewer and water laterals should not be located within proposed driveways, per standards. D 3. Include on title sheet: A. Site address 8. Assessor's Parcel Number C. Legal Description For commercial/industrial buildings and tenant improvement projects, include: total building square footage with the square footage for each different use, existing sewer permits showing square footage of different uses (manufacturing, warehouse, office, etc.) previously approved. EXISTING PERMIT NUMBER DESCRIPTION H:IWORD\OOCSICHKLST\Blllldlng Plancheck Cldst Fann (Generic),doc 2 Rev. 7/14/00 D D D D D D D D BUILDING PLANCHECK CHECKLIST DISCRETIONARY APPROVAL COMPLIANCE 4a. Project does not comply with the following Engineering Conditions of approval for Project No. _______________________ _ 4b. All conditions are in compliance. Date: _________ _ DEDICATION REQUIREMENTS 5. Dedication for all street Rights-of-Way adjacent to the building site and any storm drain or utility easements on the building site is required for all new buildings and for remodels with a value at or exceeding $15,000, pursuant to Carlsbad Municipal Code Section 18.40.030. Dedication required as follows: ________________ _ Dedication required. Please have a registered Civil Engineer or Land Surveyor prepare the appropriate legal description together with an 8 ½" x 11" plat map and submit with a title report. All easement documents must be approved and signed by owner(s) prior to issuance of Building Permit. Attached please find an application form and submittal checklist for the dedication proc~ss. Submit the completed application form with the required checklist items and fees to the Engineering Department in person. Applications will not be accept by mail or fax. Dedication completed by:____________ Date: ___ _ IMPROVEMENT REQUIREMENTS 6a. All needed public improvements upon and adjacent to the building site must be constructed at time of building construction whenever the value of the construction exceeds $75,000, pursuant to Carlsbad Municipal Code Section 18.40.040. Public improvements required as follows: ____________ _ Attached please find an application form and submittal checklist for the public improvement requirements. A registered Civil Engineer must prepare the appropriate improvement plans and submit them together with the requirements on the attached checklist tq the Engineering Department through a separate plan check process. The completed application form and the requirements on the H:IWORDIDOCS\CHKLsnBuilding Plancheck Cklst Fonn (RIDDLE· HARVEY 7-12-00).doc 3 Rev. 12126/96 D D D D D D D D D D D D D D D D BUILDING PLANCHECK CHECKLIST checklist must be submitted in person. Applications by mail or fax are not accepted. Improvement plans must be approved, appropriate securities posted and fees paid prior to issuance of building permit. Improvement Plans signed by: _________ _ Date: ----- 6b. Construction of the public improvements may be deferred pursuant to Carlsbad Municipal Code Section 18.40. Please submit a recent property title report or current grant deed on the property and processing fee of $280 so we may prepare the necessary Neighborhood Improvement Agreement. This agreement must be-signed, notarized and approved by the City prior to issuance of a Building permit. Neighborhood Improvement Agreement will include the following: 6c. Enclosed please find your Neighborhood Improvement Agreement. Please return agreement signed and notarized to the Engineering Department. Neighborhood Improvement Agreement completed by: Date: · 6d. No Public Improvements required. SPECIAL NOTE: Damaged or defective improvements found adjacent to building site must be repaired to the satisfaction of the City Inspector prior to occupancy. GRADING PERMIT REQUIREMENTS The conditions that invoke the need for a grading permit are found in Section 11.06.030 of the Municipal Code. ?a. Inadequate information available on Site Plan to make a determination on grading . requirements. Include accurate grading quantities (cut, fill import, export). 7b. Grading Permit required. A separate grading plan prepared by a registered Civil Engineer must be submitted together with the completed application form attached. NOTE: The Grading Permit must be issued and rough grading approval obtained prior to issuance of a Building Permit. Grading Inspector sign off by: Date: 7c. Graded Pad Certification required. (Note: Pad certification may be required everi if a grading permit is not required.) H.IWORDIDOCS\CHKLSnBuilding P/ancheck Ck/st Fann (RIDDLE -HARVEY 7-12-00).doc 4 Rev. 9/28/00 1sr D D D D D D D D BUILDING PLANCHECK CHECKLIST 3RD D 7d .No Grading Permit required. D 7e. If grading is not required, write "No Grading" on plot plan. D D D MISCELLANEOUS PERMITS 8. A RIGHT-OF-WAY PERMIT is required to do work in City Right-of-Way and/or private work adjacent to the public Right-of-Way. Types of work include, but are not limited to: street improvements, tree trimming, driveway construction, tying into public storm drain, sewer and water utilities. Right-of-Way permit required for: 9. INDUSTRIAL WASTE PERMIT If your facility is located in the City of Carlsbad sewer service area, you need to contact the Carlsbad Municipal Water District, located at 5950 El Camino Real, Carlsbad, CA 92008. District personnel can provide forms and assistance, and will check to see if your business enterprise is on the EWA Exe~pJ:List. Youiy teleph~e (760) 438-2722, extension 7153, for assistance. u»it-J M T .e., G. 10/r0/~ ~~!~~trial Waste permit accepte by: . c& ~~ 10. NPDES PERMIT Complies with the City's requirements of the National Pollutant Discharge Elimination System (NPDES) permit. The applicant shall provide best management practices to reduce surface pollutants to an acceptable level prior to · discharge to sensitive areas. Plans for such improvements shall be approved by the City Engineer prior to iss1.1ance of grading or building permit, whichever occurs first. 11. CJ Required fees are attached CJ No fees required WATER METER REVIEW 12a. Domestic (potable) Use Ensure that the meter proposed by the owner/developer is not oversized. Oversized meters are inaccurate during low-flow conditions. If it is oversized, for the life of the meter, the City will not accurately bm the owner for the water used. • All single family dwelling units received "standard" 1" service with 5/8" service. H:\WORDIDOCSICHKLST\Bulldlng Plancheck Cklsl Fonn (Generic),doc 5 Rev, 7114/00 D o. D 12b. • • • BUILDING PLANCHECK CHECKLIST If owner/developer proposes a size other than the "standard", then owner/developer must provide potable water demand calculations, which include total fixture counts and maximum water demand in gallons per minute (gpm). A typical fixture count and water demand worksheet is attached. Once the gpm is provided, check against the "meter sizing schedule" to verify the anticipated meter size for the unit. Maximum service and meter size is a 2" service with a 2" meter . If a developer is proposing a meter greater than 2", suggest the installation of multiple 2" services as needed to provide the anticipated demand. (manifolds are considered on case by case basis to limit multiple trenching into the street). Irrigation Use (where recycled water is not available) All irrigation meters must be sized via irrigation calculations (in gpm) prior to approval. The developer must provide these calculations. Please follow these guidelines: 1. If the project is a newer development (newer than 1998), check the recent improvement plans and observe if the new irrigation service is reflected on the improvement sheets. If so, at the water meter station, the demand in gpm may be listed there. Irrigation services are listed with a circled "I", and potable water is typically a circled "W". The irrigation service should look like: ~ . -- STA 1 +00 Install 2" service and 1.5: meter (estimated 100 gpm) 2. If the improvement plans do not list the irrigation meter and the service/meter will be installed via another instrument such as the building plans or grading plans (w/ a rig,ht of way permit of course), then the applicant must provide irrigation calculations for estimated worst-case irrigation demand (largest zone with the farthest reach). Typically, Larry Black has already reviewed this if landscape plans have been prepared, but the applicant must provide the calculations to you for your use. Once you have received a good example of irrigation calculations, keep a set for your reference. In general the calculations will include: • Hydraulic grade line • Elevation at point of connection (POC) • Pressure at POC in pounds per square inch (PSI) • Worse case zone (largest, farthest away from valve • Total Sprinkler heads listed (with gpm use per head) • Include a 10% residual pressure at point of connection 3. In general, all major sloped areas of a subdivision/project are to be irrigated via separate irrigation meters (unless the project is only SFD with no HOA). As long as the project is located within the City recycled water H:IWORO\OOCS\CHKLST\Bullding Plancheck Cklsl Fann (Generic),doc 6 Rev. 7/14/00 J 1ST 2ND 3RD D D D D DD 12c. BUILDING PLANCHECK CHECKLIST service boundary, the City intends on switching these irrigation services/meters to a new recycled water line in the future. Irrigation Use (where recycled water is available) 1. Recycled water meters are sized the same as the irrigation meter above. 2. If a project fronts a street with recycled water, then they should be connecting to this line to irrigate slopes within the development. For subdivisions, this should have been identified, and implemented on the improvement plans. Installing recycled water meters is a benefit for the applicant since they are exempt from paying the San Diego County Water Capacity fees. However, if they front a street which the recycled water is there, but is not live (sometimes they are charged with potable water until recycled water is available), then the applicant must pay the San Diego Water Capacity Charge. If within three years, the recycled water line is charged with recycled water by CMWD, then the applicant can apply for a refund to the San Diego County Water Authority (SDCWA) for a refund. However, let the applicant know that we cannot guarantee the refund, and they must deal with the SDCWA for this. 13. Additional Comments: H:\WORDIDOCS\CHKLST\Bulldlng Plancheck Cklsl Fonn {Generic).doc 7 Rev. 7114100 fep-29-00 OB:33 CRE/Collision Repair Equi (B58)74B-B424 P.02 lSl D 0 \ \ l~DD \ \ lJ DD ' PLANNING DEPARTMENT BUILDING PLAN CHECK_ REVIEW CHE,?f~I Plan Check N . CB 4'1 Addren ....P..~---:---if--------- Planner -~4-4-1111--i'~~..,...--Phone (760) 602· --:a~~....._ ___ _ APN: _____ ~1'"-l:--~--,/1,-:------------ Type of P~ect & Use:'--61rif .......... -t----,""""-Net Project Oensity:, ______ p_u_t .... A-=C- Zoning: )/M Gene I Plan: Facilities Management Zone: __ _ CFD (in/out) # _Date of participation: Remaining net dev acres: __ Cln:180na (For non-residential development: Type of land used created by this permit: __________________ _ LMfQd; C8J Item Complete O Item Incomplete • Needs your action Environmental Aev•w R•qulred: YES_ NO __ TYPE ___ _ CATE OF COMPLETION: _____ _ Compliance with a:indltions of approval? If not, stat; conditicna which require action. . Condition.t of Approval: Dl.cretlonary Action Required: YES_ NO_ TYPE ___ _ APPROVAURESO,NO, · DATE ___ _ PROJECT NO._· _____ _ OTHER RELATED CASES: _________________ ~ · Compliance with oondltlona or approval? If not, state conditions which require action. Conditions of Approval: __________________ _ Coastal Zone M•••menl/COmpllanae Project site located In Coastal Zone? YES_ NO_ CA Ccutat Comm!seion Authority? YES __ NO_ If California Coastal CommiNion Authority: Contact them at· 3111 eam;no Del Rio North, SUite 200, sari 011go CA 92108-1725; (619) 521--8036 Determine status (Coastal Permit Required or Exempt): Coastal Permit Determination Form already completed'? YES_ NO_ If NO, complete Coaetal Permit Ottlrmlnatfon Form now. Coastal Permit Determination Log #: FaUow•Up Actions: 1) Stamp Building Plane as "Exempt'' er "Coastal Permit Required" (at minimum Floor Plans). 2) Complete Coastal Permit Determination Log as needed. ~ep-29-00 08:33 CRE/Coll;s;on Repa;r Equ; (858)748-8424 P.03 I J O D lncluslonary Housing Fee required: YE$_ NO_ {effllCIIYI crate of lndusi0muy liovq OtdNnC4t • May 21, 1993,) Data Entry Completed? YES_ NO_ (,IJPIOI, AdMty Maintanance, .-, Cl#, toolblr, ScrNns, HCIUllng l'eol. Construct He>1J11n; YIN, Enler Fee. UPDATI:I) . Site Plan: 1. Provide a tulJy dimensional site plan drawn to scale. Show: North arrow, property lines, easements, existing and proposed structures, streets, existing street improvements, right-of-way width, dimensional setbacks and existing topographical tines. { J O O 2. Provide legal descrlpticn of property and assessor's parcel number. Zoning: [] 0 0 1. Setbacks: Front: Interior Side: Street Side: Rear: Required ______ Shown _____ _ Required ·Shown _____ _ Required Shown _____ _ Required Shown _____ _ ( ] 0 D 2. Accessory atruoture setbacks: Front: Required ______ Shown _____ _ Interior Side: Required Shown _____ _ Street Side: Required Shown _____ _ Rear: Required Shown _____ _ Structure separation: Re~uired Shown _____ _ · {] 0 0 3. Lot Coverag, ... e; __ ( J D D 4. Height: Bequiced ....... Shown _____ _ Requlrecl __ __,.. ___ Shown _____ _ [ J O D 5. Pari<ing: Spaces Aequir&d ______ Sho~n ____ _ Guest Spaces Required;_· _____ _ C 1K TO ISSUE ANO ENTERED APPROVAL INTO COMPU~ 1-1:\AOMIN\COl,INT!R\BldgPlnchkR•vChklat Carlsbad Fire Department 003154 1635 Faraday Ave. Carlsbad, CA 92008 Fire Prevention (760) 602-4660 Plan Review Requirements Category: Building Plan Reviewed by: Date of Report: 09/18/2000 ------------ Name: Rick Lien Address: PO Box 930 City, Stat~: Poway CA 9207 4 Plan Checker: Job#: 003154 ------- Job Name: Abtech Systems Bldg #: CB003154 ------------------ Job Address: 2777 Loker Avenue West Ste. or Bldg. No. [gl Approved D Approved Subject to D Incomplete Review FD Job# The item you have submitted for review has been approved. The approval ·is based on plans, information and / or specifications provided in your submittal; therefore any changes to these items after this date, including field modifications, must be reviewed by this office to insure continued conformance with applicable codes and standards. Please review carefully all comments attached as failure to comply with instructions in this report can result in suspension of permit to construct or install improvements. The item you have submitted for review has been approved subject to the attached conditions. The ~pproval is based on plans, information and/or specifications provided in your submittal. Please review carefully all comments attached, as failure to comply with instructions in this report can result in suspension of permit to construct or install improvements. Please resubmit to this office the necessary plans and / or specifications required to indicate compliance with applicable codes and standards. The item you have submitted for review is incomplete. At this time, this office cannot adequately conduct a review to determine compliance with the applicable codes and / or standards. Please review carefully all comments attached. Please resubmit the necessary plans and/ or specifications to this office for review and approval. 1st 003154 2nd FD File# 3rd Other Agency ID SAN DIEGO REGIONAL HAZARDOUS MATERIALS· QUESTIONNAIRE -OFFICE USE ONLY H# ________ _ BP DATE---'----'---SA/M·.·· ---------AP CD _______ _ /Do Plan File#/Permit# PART I: FIRE DEPARTMENT-HAZARDOUS MATERIALS MANAGEMENT DIVISION: OCCUPANCY CLASSIFICATION Indicate.by circling the item, whether your business will use, process, or store any of the following hazardous materials. If any of the items are circled, applicant must cortact the Fire-Protection Agency with jurisdiction p··ior t,::, plan ·submittal. 1. Explosive or Blasting Agents 4. Flammable Solids 7. Pyrophorics 10. Cryogenics 13. Corrosives 2. Compressed Gases 5. Organic Peroxides 8. Unstable Reactives 11. Highly Toxic or Toxic Materials 14. Other Health Hazards 3. Flammable or Combustible Liquids 6. Oxidizers 9. Water Reactives 12. Radioactives PART II· SAN DIEGO COUNTY DEPARTMENT OF ENVIRONMENTAL HEALTH -HAZARDOUS MATERIALS MANAGEMENT DIVISION (HMMD)· If the answer to any of the questions 1is yes, applicant must contact the County of San Diego Hazardous Materials Management -Divisioo,-,.1255 Imperial Avenue, 3rd .Floor, San,.Diego, CA 921 Q1.. Telep.hone. .(619) 3.3.8-2222 p,rior to the issuance of a building D CalARP Exempt department permit. / FEES MAY BE REQUIRED ~ No · . 1. Is your business listed on the reverse side of this form? · _ 2. Will your business dispose of Hazardous Substances or M~dical Waste in any amount? 3. ~ WUI you, bu,;n,ss "'"' o, handl, Ho,aodou, Substanees In quantit;,, ,quol to o, "'""' than 55 gallons, ,- 4. :=- 5. ==' ·5. 500 pounds, 200 cubic feet or carcinogens/reproductive toxins in any quantity? : Will your business usa an existing or install an underground storage tank? ~~~Will your business store or handle Regulated Substances (CalARPI 7 _ >!~Will your business use or install a Hazardous Waste Tank System (Tit:e 22, Article 10) PART Ill: SAN DIEGO COUNTY AIR POLLUTIONS CONTROL DISTRICT Date Initials D CalARP Required I Date Initials 0 CalARP Complete I Date Initials If the answer to any of the questioi1s is yes, applicant must contact the Air Pollution Control District, 9150 Chesapeake Drive, San Diego, CA 92123 . . :;I_)1.lephoriQ· (619) 694-3307 prior to the issuaoce of a building department permit • . 'Y.ES NO ., 1 . ~ 0 Will the intended· occupant install or use any of the equipment listed on the Listing of Air Pollution Control District Permit Categories, on the ,i....J, reverse side of this form 7 · 2. 0 00-,. (ANSWER ONLY IF QUESTION 1 IS YES.) Will the subject facility be located within 1,000 feet of the '1Uter boundary of a school (K throu,gb 12) as listed· in the currEnt Directory of School and Community College Districts, published by the San Diego County Office--of .E.ducation and the current California Private School Directory, compiled in accordance with provisions of Education Code Section 33190? 3. Dees the buildin or structure for which this friable asbestos? Briefly describe business activity-and proposed project: ... J'»oJn-H n Date FOR OFFICIAL USE ONLY: FIRE DEPARTMENT OCCUPANCY CLASSIFICATION:-_____________________________ _ BY:. ____________________________________________ Date: _______________ _ EXEMPT OR NO FURTHER INFORMATION REQUIREO RELEASEO FOR BUILDING PERMIT BUT NOT FOR OCCUPANCY RELEASED FOR OCCUPANCY 0 --v'V ~N -. COUNTY-HMMD APCD , :'\, C,.95'~T'(}'lfM~J , , • APCD COUNTY-HMMD APCD ~v~ I ' ~..;;':' --, 0/ ~fw::~ 1'1(, 41t'10\ '¢J' -RfVfE:Jffr, ~ @) a'I ,. "flc''f ' ,i;/.4 " .. ,, ,.,_ 1B-r,-c£11~~~ ~ . ''· $ ~~LIC'"l:.D ·•,: -'? SIGNAT" Rf: bf " .,. ~ 1-i;_.,,, _l\-.t:~~~-:w-~ l?-J,d;i,..;., ,...,. DATi: ... f!MM\:!.,,./ {' ...Av¥~!!J,~ &:~-.~ .,;~TI:. .~C:i: \J Ai,i.\e-'itiii'r;;;.\\~ le, "ft JJ .. p_: ....... •,; \\ Coun of San Di ty eg 0 DEH:HM-9171 (10/98) Department of Environmental Health .l l r . ; ROOF DUCT I NG PENETRA T 1·0N FRAM I NG HEAD OUT DET A IL ~ S IMPSON JO I ST HANGER 9 GA. STRONG 1 /11/ ,--------2 -2" X 4" HEADERS NA I LED EVERY 6 11 , 12 PENNY --, ~--------~ \ I .--. - \ I ' ~ IV '---' - ~ ~ '. ' - I~ ~ b._,__ LJ 2" X 4 11 ROOF JO I STS , 2 ' 0 .C . ; ·NOTE: SEE STANDARD DUCT DETAIL FOR CLEARANCES ~ ~ ;.::-- '-.' L.J 00TH INSTALLATION FOR: ABTECH SYSlEMS 2728 LOKER AVE. CARLSBAD, CA 92008 SCALE: NONE BY: COLLISION REPAIR EQUIPMENT 14260 GARDEN RO., STE.11A POWAY, CA (619) 748-7446 DRAWN13Y: ·I DRAWING#". MICHAEL RENWICK DATE: I REVISED BY: 1 SEPTEMBER 28, 2000 Nor&. P Na: E!)(J9TING lt.8 AATINO 225A M.4.INC.I. AATINO NO PAt-8. flB)llATINO 2tGA IM11..ae.. ~J"~ctf' I. te'i CIRCUT IIRlW:m, NEW LOAD ":. EXl9TINGCUlClJT U&Jo;ER. 8'1STINGWAD J. l'XIST\HGCIRCUT I l\6'1CER. Nat lQAO 2C8'//120V 3PH 4W PHMESlSTOfAU: PA.h"'EL D A • l4'n VA a • .1'92J VA C • . 11'0 VA. TH1¥>WiFIB>l.OAO I VA .~ .......... . .AIC~ t•kAIC H:>LNTlNGTYPB SlRFACE' . NIMATYP& l fB:DllOUICB tDT. IOAJlO' M3A' 5UTOTM.• SO.t,VA l( 1.ZJLCl• l2'Zt VA TOTAL• Ullt VA US AMPI J:181#11, '~ ... ., .. ~..,_,..,.._ 1.l . , ...... ·----·~·-.. (J It -c I r-e I C C C L ( I! , f ? ' C t C ' .... STANDARD DUCT DETAIL (1990) 18 go., go.lv, duct~~. __ . __ _. __ fo.n/duct clea:nout door Mrn. 6' Booth Mount Fon/ Combustible Roof Da.npered ro.in cap ~ Motor cover~ ,~"7' I F'a.n Roof Jo.ck· Existing ro_of~ 18 go. golv. duct ./ ----------. . . . ----------. . . LJ Hin, 6' Roof Mount Fon/ Non-Combustible Roof & COMMON ura:----,.20-v,i.c r--,. HOT . ·--------1 2-40 W.C J/ 240 VAC 3tf DISCONNECT SWITCH DISCONNECT SWITCH LINE ~ 30 .Al.IP 3' 240\fAC 30 .Allf' I I I I I . I _______ (h/4_-r----------=~-- 1 I I I I I ~ 3 ").., 2-40 VAC COMMON TRIP 30 ..cMP S1i STOP 10GGl£ SMTCH Ml OL 2-40 VJC. NR SOI..ENOIO V~',£ SPRAY BOOTH MOTOR ANO CONTROL Tl T2 TJ EXHAUST f".AH 2-40/120 VAC 3' 4W .. 2-IO V,,C J,t 2 tp MOTOR 5.9 AMPS 20 AMP CfiCUIT BREAKER t :LIGHT M t BOOTH TYPE ' REL'l-11# · IIPIUlrBIJIITH COMPANY .,,,...,.,,,._,. ...... '°'w.w T._llll;lff,1UII '"!Wl"'•'IM l!Q.AJ.llh DA'l'ZI nL'C JfAME: ,/ O8/2!:l/98 09:24 CARD It JAL EM SAL f: 17608275122 t-1O.927 .. ,, --. product j3600 SERIES information !WATERBORNE ACRYLIC l AIR ORY ENAMEL A R D I M A L Vov,;ti~ INDUSTRIAL FINISHES 11194 Cardinal's 3600 Scric3 Acrylic Waterborne Air Ory Enamel is monuractured lo meet the mo:it stringent Air Quality Regulations. Thl:i product line has 11n excellent b11l11nce of faot dry, tough rum prop11rtio11 and economy. II can be :,ppllcd lo properly prep:,red !!Itel, aluminum. pla::.1lc Md wooe1 substralo$, 3600 Sorlos produc1s contain llnle organic co-solvont!I • hcorth and oarety, llro and envlronmcnbl risks :ind llablrillee are lhereroro mlnlmlzod. • TYl'ICAL Uses: BENEFIT;,; • Top coat lor aecorauve and pro\ecllve u&e on met~. pla&llc, and wood p(O(SUCIS. • Low voe con1enI. • Very fasl dry time. • Hard abrasion resislent film. • Business machines. • General metal linishing. • Wooden fixtumi. • Very low fire hBZBrd. • Water clean up. • Ready lo sp~y. CuRso F1LM P'to~rn;s: Unless ou,erw1se Indicated. testing coo~ucted on 3607-10 gloss while el 1.s mils OFT over 20 g\mgo Bondarlto 1000 treated cold rolled stool, force dried 30 rnin. ot '80'F then air drled for 14 days. TEST METHOD Impact: Fle.xlblliry: Hardness: Abrasion: Salt Spnsy: Chemical& Stain Re.slslance: ASTM 02794 ASTM 01737 ASTM03363 ASTM04060 ASTM 8117 ASTM 01308 30min.spol -r-r-A: No elfect (pla&tle~ 8: Sllgllt dulQng subslrata) C: Moderate el/cct O: Ol:.colorecl & softened E: SVl!ffll detetlorallon PARAMETERS Direct 1/8' mandrel Pencil CS-17 wheels,\ kg, 1000 cycles RESULT 30 In. lbG. No cracking Less than I 00 mg loss 100 hn,. 95', 5% 011ll No bllotorlng; Joos than 1/8 Inch soluUon creepage rrom scribe. A • 0.1 N 11c1. Lemon JulC'5, ArUllclal Perspiration, Coff88, lvoty Uquld 01&'1 Soap, Tap Waler, Snap Antl-&latic Cleaner. Spic & Spin, Mustard, Suparller Slue Fell Pen. Fal)Sr-Caslell BallpBn, Freon TF, Vasenne, Lipids {fatty acids). Corn OIi, WC-40. B • Ammonia, Methylene Chloride, Fonlostlc, Liquid Paper. C • Super11trlp Floor Slrlppor, 70% lsopropyl Alcollol, Butyl CelloflOlve, 1, 1, 1 TrlchlorMll'lane, Lipids (24 hr. expoi;ure). O• E • Methyl Elhyt Kelooe. Su~FACE PRel'AAATION AHO PNMJHC.: The most importimt ste~ io a i;uccessful co21Un9 process are cleaning, pretrealmenl and priming. Tha rollowtng Is· a brier outllne or some bas:ics for unpainl9d substr.it,u;, 11 IG not lnle!ll1ed lo be au l11cl11alve. For more informellon on your particular appllcatlol'l, do not hesitalc 10 call Cardinal, Cleaning the substrala: All surt21ccs to be coalcd mu11c bo free or dlr1, 9re1111c, oil, oxldollon. mill ~ale, and an other contaminnnts. ihe sur1aca must be thorou9hfy dry befOTe p;ilnling. Air quality reg\llatkif,5 hilvc llmlled the allowable omlssion:i rrom cleaning oporaUOn:J, cg •• SCAOMO Ruic 1171 So:v11nt Cloanlng Operallone, C11rdln21I &upplles products that complywith Chi$ rule. YPe: Ac,ytlc Emulslon COMPONENT$; one. COLORS: Full range lnclUdlng Fed. Sid. S95b. GLo&s: High (701, semi and net. MINIMUM ORt:11m: f ~lion. CoveRAoe: At I mil dry (ilm thickness (OFTI 620 ft1/93I al 1 oori-lr.ancfor 11rnclency 330 tt21ge1 at tl5'l6 tral\sfer emc1ency Cak:ulal:011: 1604 R1/gol 11 'I\ ~oh,ma '°Ude" tr.>nt. r,/f, • OFT VQC: (a:i $Upplicd. maximum) 252 grams/liler (2.10 lbsfgel) less waler. • \ 102 grams/Iller (O.BS lbs/9el) lncllldlng waler. ~ V ~ 01.vME Souos: 31 % • 35% FLASH POINT: >212'f TCC SMrai= L1i=;: 6 moottis from date or manuracl1.1re on the unopeneo container. APPLICATION: Sea Surface Preparation and Priming section. This malerlel 15 designed for spray appllc:aton. Brushing, rolling, or dipping ara not recommanciad. Texturing: Apply smooth base coal and alt dly 10-15 min. Apply lcxturc coat by lowering atomlzin9 pressure so os lo spatter paint onlo base coat. Tho lower the 01omizlng pressure, !he larger the texture. THIHNIHG! Relldy ror spray. If thinning is necessary. use water, , ".6 • S'l&. AVOld over lnlnnlng. v1scos1TY: 35. 45 &econds, #13 Zahn cup at 1a· F. R6COc.tM6NC6D F1LM THICKNliSS! 1,0-2.0 mils: CURE: ~ Force Ory• Tack free 15 min, I 30 min at 140' F ·\ __Jqi.10 baru1IB 2 hrs~ 20 min at 1eo• F ·· Pull Cure 7•10 d€ 10 min at 180" F (l',I 1.S rnlltJ Ory lilm lhickne$$, 78' F, SO% RH) • AQMD requl~ mQ)(lmum temperture or 194"F to quallry as an ·air dry" sy&tem. Eau1PM1.HT: Mo;t air ~uality regulaUons require the palril application transfer emciency to be 65'36 or b~er. Tnls gBnerally me.z,ns using cr~tro~taUc or high volume low pressure (HVLP) apray guns. CAUTION: Electrostalic equipment needs ta be properly isolated ror waterborne UGC. Fluid and air hoses should be o minimum or S/16" ror air aupp1y and 31a• ror lluid. CLEAN.UP: Warm waler. 1r something stronger Is needed for ciean up of dried build up, keep in mind I11at air quality reoulolions hove limited lhe ellowable eml$Sions from olc11nln9 operatlo1'13, eg .. SCAQMO Rule 1171 Solvent Cleaning Operations. cardinal supplies materh1l:i lhal comply wHh lhls rula. SrttJI-A phosphate chemical conver$10n coaling Is highly recommended. When tnla l:s nol possible, r, vinyl acid wasn pretreatment primer h:i recommended i:uch :ic C:irdlnars 4860 PRODUCT UllllTATIONs: ' ' '· serie3 primer:i. • AVOID FREEZING -Producl cont11ins water, ~luminum -A ch&mic:al conversion coaling is highly recommended. When lhl& 1, not · • S~rage stability Is limited to 6 months. possible, a \l\nyl acid wash pretrc:itment primcir is recom'!IC11ded sli!A:s Cl!rdln:ir~-~;1 • ~Tl mm proPJ;lllili. depend on.-rru"'"'_,.,,...,see •i I ---'"--------------":,. ....... ____ ...., ______ _ j~ONTE, CA. "i'!!lt+odllv ,wa., 111733 • (21~) co.)·~• (8"""""'·1'274 • .. t 1oj' 444·03B2 SAN JOSE, CA. 890 Commercial SI., 95112 • (4~ 4S2·852Z • FAX: (40&) 4~2·0318 PHOENIX, AZ. S818 E. SupCIC'ior A.vo., 85040 • (802) .t37-2401 • FAX: (602) 437-9251 DENVlffi, CO. 119S E. 64th Avo,, 80228 • (30~) 2611-1876 • FAX: (30~) 280-1878 NO WAkn,;~rr EKPlfESSED OR IMPLIEO, ACCEPrABILITY ro BE DETERl.f/N{;O BY USER. SPEC/FICA T10NS ARE SUBJECT TO CHANGE WITHOVT NOTICE, .,,,, l ( .. (18/28/98 3600 SERIES 09:2~ 11/94 CARDINAL EM SALE -t 17608275122 t--10.927 [;)03 Page2 ---·-·--------·-· -··--· scrle:i primer~. -Galv1Jnizod -Cardln:irs W030:3·A surface preparation solullon help& Improve adhesiori lollowed by :i 11lnyt ~Gld W:1$h prQlre:itmenl primer such as C;irdinal's 4860 nries primers. Stsinloss Stnt -Brush-off blast clean pet .SSPC-SP 7 \o a uniform profilo of 1.5 mils. Cardinal's W•303-A si.rface preparation solutlon can help improve .adhesion followed by a vinyl acid wa,r, pretreatment primer such 3"3 Cardinal"s 4660 serkis primers. Praso·c -Any mold release shoul<l be complelaty removed. 3600 serleG air dry enamel is . compilible with a varleiy of plast~s. however, sinca there are numerous <tiITerenl JL.. formulalions of plastic, a lri3l sample should b9 painted and checkod before running 1\ ., production. wo r:>d -3600 $l!r1es Is no\ recornmencJcd ror extortor WOOd appllcalions. 8ecause of the wide variety or woods 21nd pos-,lbte 21ppe21rance wriall01l8, it Is recommended lhDI your panleutar application be discussed with a ·cardinal sales representati'ie or our in-hour.A leehnical serva staff. PRIMER SE\.EC:TIOH: PRODUCT NO. DESCRIPTION FUNCTION · 3660 W/6 Pnmer Surfacer Some filling for metal and\\Wd. ·3760 W/B Plastic Primer Adhesion and some llUlng (ct pl:l:tlc. 3660 w,e Antl-eorrosion Primer Corrosion Inhibiting end adhesion. 6460 NF-..,./ Two Part PolY\Jrelhane Tough surfacer far plastic :ind WOOd. TROUBLE SHOOTING: PROBLEM CAU~E. R!MEOY T co tnlo I low Over reducoo. Cont&Ct cardinal ,epresentatlve lor p<r.i· viscoslty pH too IQW (evaparatlon from sible rewont. open container}. DI)' spray High shop \11n,pgrglUtQ, , tncraasa fluid pro"ur; & d;cro11;Q QI- om!zing pressure. Reduca wltl\ water: 1 % -2111.. A<IO Butyl Carbllol or OPG at rale of , ozJgat. Flash Nsling Colr;J end/or humid weather. Warm paint 11nd p11rta to 10• • 80"F. Cola &ucstra\e. Bul'JI ceuosol\la at , 01Jge1 may help. Over reduced. Muoeraoklno Over reduced Butyl Csrbltol et 1 oz.Igel mey help. ,j• FIim build too high. La.vet nlm bulld, Craters Conl11minr,lion of subs\ralc, llP-Find llOd cllimlm1Ie ~rec or contamln!- plicsllon equipmenl or environ-\Ion. menl PQOI" adhesion Improper surface preparallon. see surfa~ preparauon s~. I Film too ltun to coal~ prop-11\c(effO mm build. erly. PA.OOUCT IOENTIFIC:ATIOH 3 6 0 7 -1 1 3 5 0 (example) ITIL LcolorNumbcr Gl~s: 0 • net, 1 • 10•, 2 • 20•, •• elc. 7 C# 70" high gloss Specla1: eg., 2 = mel!llllc, 3 = nammer. 4 = lexture. 6 = primer. 7 = clear Product type Curo :section. SAFIITY! Contains or9:anic solvenls. Use with adequa111 ventilation • do not breath vai;,ors or spray mists. If c:ompononl TLV:i. arc exceeded. a NIOSH / MSHA approved ;iir supplied respirator is advised. See MSDS forTLV lnformallon. Keep from tieat, sparks or open name. Avoid contact wit'1 eyes, skin, and clothing. Wast, thoroughly al\Cf handling. First Aid: Eye conrac:1. nush 1mme<11a1ety wltn plenty or w-ate< for at 1011st 1 S min. and get medical otten1lon. Skin cont11ct, wash thorooghly with soap and water for 5 minutes. If swallowed. do not Induce vomiting and gel medical anen\lon lmmedtateiy. lnhaJadon, remove lo fresh air. RELATED PROOUCTs: PRODUCT NO. DESCRIPTION OPG Olpropylene Glycol • slow solvent Butyl Cetrosotve Stow eorvent. poalesclng agent. Ammoola f\alSes pH or pain!. A·50 Flash rust addillve. I • 1MPOI\ t ANT: W)rnnty )~d OISCl)irncr -Tho pQrfo1~nco char;e101i11ie, v( \11010 prod..as ~'1 :1:1:11rdi"9 IO pradi,r;\ ~Dpli~a~Oft. 0IX)~Una ~di1iona, 111a\er,;1s >pplied 10 01 Wl1II ~nd use. Si11ca •hr.n IKIO" c~n >11..:1 •••v•ls, •• 11101191, ,eco,..,..ond lhal yo,, makt yuvr -n 10,1 lo delcrm;n• to ,ov• H~sladia,,..,..har u,o p,OOvCI is al :,ccaptablt qu1lity. h;s not boon a"o~ed !Ir \\Or:,go ot l'~n1oor1 lft~ It sv;l:,blt l')f ~ P~fllCu"r pvrpo,• vndlr your """"gper,llo11 cQM!lllollt prior 10 uGlng any orOdvi:l in,.,. 0010 p,odu<:1io<1. Sellor wa,r,,1115 Ill• p•?duCIS to M lrH lroM dflK!'I ;., ,,, ... , •• r. ~·o _,_,,,,ft,h,p. iUCM WAR~AIITY IS 6XCI.US1Vli AND IS IN LIEU OF ANY OT)IER W~RANlV, t)Cr>REl>SEO OR lh'P\.IEO, 11,1c:1.u01~. BUT flOT Lll,tlTEO TO. AN" IMPLIED WAAnANlV 0~ MliAC:HM•lA811.f!V or: rrrwi;::~ ~OR A PARYICVV,R PuRP0$11. No reptHt•"'lt-;o Cl owra r.,n ;uU,,,,•ly lo w:ai\OG Of c;l,:,ngo lhis provisn,n. -~;ch :,ppliea 10 all,,, ... al \lino prad..c:1~. -----· -~ .... ........., ~-.... ... . . FlRE: --REACTIUITY: Ii.: ~ OTHER: .__ ________ _ .--~~-------!. PRODUCT INDENTIFICRTIDN----------- DATE PREPARED JANUARY 10, 1989 REUISED HAY I~, 199~ PRODUCT CODE: 119003 TRAOENAME: ·! ACETONEf COMMON NAME: 2-PROPANONE DISTRIBUTED BY: TRl-CITY PAJNT Corp. -(See section VIit.) ADDRESS: 9282 MIRAMAR ROAD SAN DIEGO, CA 92126-4419 PHONE: (619) 530-1666 24 HOUR EtERG.ENCY ASSISTANCE---- CHEMTREC l -800-424-9300 NAT I ONAL RESPONSE CEt./TER l -800-424-9300 SAN DIEGO POISON CENTER(619)294-6000 EMERGENCY RESPONSE GUIDE NO. 26 24 HOUR NON-EMERGENCY (800>-CMA-8200 -----------II. HR~RRDDUS INGREDIENTS------------ CHEMICAL NAtES <EXPOSURE LIMITS IN AIR> ACCIH OSHA OTHER ~CETDNE BENZENE ff 30PPH CAS NUMBER 67-64-1 71--43-2 (TLU> <PEL> 750ppN 0. lpp,ii 750PP,i 1 pp K n/1 fSKIN Wt. 100 ** THIS PRODUCT cont1ins TOXIC CHEMICALS iubJect to the reporting require,ients or SECTION 313 of the EMERGENCY PLANNING AND COHHUNITY RIGHT TO KNOM ACT or 1986 ind of +O CFR 372. -----~------III. PHVSICHL PRDPERTIES------------ tpor density (air=1)2.0 Mel'tin9 point or range, Deg. F < 32 ,ecific grivity 0.792 PH n/ Boiling point or nn.9e, Deg. F' 133 ,lubility in water MODERATE Ev.apor.ation r.1tc Cbutyl.Hehtt = 1) 5.6 ·.por prtssure at, 20 deg.Ca 186 ·csr. VISCOSITY e -4-0 DEC. C a: n/.a pe1r,1nce lnd odor: ~ATER J.IHITE HITH FIN;ERNA!L PCX..!SH ODOR V.O.C. = 790 gr1Ns/liter V.O.C. =-6.63 pounds/g.allon ---------------IU. FIRE RND EXPLOSION------------ ASH POINT, Dep.F l. Method -15 TCC Auto ignition ft,ipenture, Dep.F' ri/,1 u1 u b l c li ,d ts i n 1 i r, v o l u" e 1/. lo II tr ( LEU 2. 1 S upper <UEU 13 ~ EXTINGUISHING t-EDIA: Use 11.1hr rog, fo.ttt, dry che,iicil or CO2. Do not use ,1 dir,ct strea.K or 11.1hr >duct will (lo.at .tnd ctn bt rej.9nittd on surrac, or w,t,r. ~CIA!.. FIRE F!GHTINt; PROC:EIX..RES AND PRECAUTIONS: ~.rning! FLAMMABLE! Clear fire .arc.a ,or unprotected ·sonntl. DO NOT tnhr confined fjrc splCt wi1hou1 full bunt.tr 9e.ar(Htl11t1 with rH, shje]d. &int.tr its. Gloves ,nd rubber boots). including ,1 positiv, pressure NIOSH .approved selr-conhintd brHth- ' .a pp u , t us . Co o l r j re -ex p o H d co n h i n tr s . JSUAL FIRE AND EXPLOSION HAZARDS: Conhintrs exposed to inhnse he.at rro11 rir,s should be cooled h water to prevent v,por pressure buildup which could result in cont.ajntr rupture. Cont.ainer .ar,as osed to direct fl.a,ie cont.act should be cooled with l.argt qu.tntities or w1ter .as needed to prevent tening or container. 03 ACETOHE PAGE 1 19?5121i ~UJSED: MY 15, 1ns :.,.. __________ _ ~ ANO EFFEC1S CF EXPOSURE:-------- m cn-rTACT: qquid is irdhtin9 to th• eyu. Kly caust p1in, turin9, ud inf'luutiol'I. High upor conc1ntr~tions 111,y ~lso bt irrit1tin9. ~IN COOTACT:· Liqujd is 1111 ldly Jrrlhtjn9 'to tht sr.ln. Prol0n9td or npuhd liquid conhct eu1 ruult in d1t1ttin9 and drying of tht stin which 111ay rtsult in stin irrlt&tion and dtr111&tltis. ItiiALATION: Vapors uy bt irri'htln9 to l'IOSt., thrott ud uspiutory tnct. High Y&por coracentutions HlY eaust CNS depression. !~ION: lnptstion of product KlY ruur:t in voKitinp; aspir&'tion (bruthlnp) or ·vot1itus into tht lunp .shoul"d bt uoidtd u even u,1.ll qu,1.ntltits K&y ruul't in Aspirition PntuKonltls. · Slc;NS AND S'r11PTOMS: lrrlhtlon u nohd &bOYt. Euli, to 11od1nh CNS (Ctntrtl ntrYous si,stu> dtprts- slon K&y bt tYidenctd by glddintss, ht&d&cht, dizxlntss and n&ustl: ln txtrtKt cases unconciousness and delth 111&y occur. Asplrttlon PntuKonltls K&y bt 1vld1nctd by coughlnp, l&bortd brt&thlng &nd cy&nosis (Bluish stln); ln stvert cases de&th K&y occur. At;;RAVATED MEDICAL romITIONS: Prt-txlsting eye, &nd respir&tory disorders 1111y be aggr&Ylitd by exposure to thls product. OTHER HEALTH EFFECTS: lntentioul ,bust, tdsuse or Kusivt exposure 11&y c1use t1ultiplt orgu du&pt &nd/or duth. CANCEROUS PROOtCTS OR POTENTIALLY CANCEROUS--- N D X YES PROD U CT C S ) : Mn~ f"-' h FED OSHA LIST. FIRST AID: EMERGENCY PROCEDURES-------- EYE CONTACT: Hold eyelids open and flush with plenty or water for 15 t1inutes. GET HEDICAL ATTENTION. SXIN CDNTAC"J:r.: RtKove conh111inattd clothing and shots. Flush st.in with water. Follow by washing with soap and water. If irritation occurs, c;IT 11EDICAL AT,:ENTlDN. DD NOT reun clothing until cluned. INHALATION: ReNove victiK to trtsh air, ir bre...thing is difficult. provide oxygen; Hnot bre.thing provide artificial respiration. GET 11:])lCAL ATI"ENTlON. 'IH;;ESTION: DO NOT IHDOCE VOMITING. Ir 1,101d ting. occurs sponhneous ly, l:.ttp hud be low hips to prevent · aspiration or liquid into _lungs. GET MEDICAL ATTENTION.I ·PHYSICIAN NOTE: ilr Kort than 2.0 1da9 hu been in9esttd and vo1dting hu not occurred, tKesis should be induced with supervision. Keep victiK) head below hips to prevent lsplration. Ir syKptons such as loss or 919 reflexes, convulsions or unconsciousness occur before e111esls, gastric lavage ·using a cutftd endotracheal tube should be considered. ---------------VI. REACTIUITV DATA-------------- STABILITY: X STABLE_UNSTABLE HAZARDOUS POLYMERIZATION HAY OCCUR X WILL NOT OCCUR CONDITIONS AND MATERIALS TO AVOID: Avoid heat, spar~s, flaNe and contact with strong oxldi:ing agents. HAZARDOUS DECOMPOSITION PRODUCTS: Carbon Konoxide and unidentified organic coKpounds Kay be rorKtd during coKbustion. 11?'003 ACETOIIE PAGE 2 19YS1211 f:EUISED: JAKMRY 2P, lnl .~tLL CJ< LEN:~: '-'arfti~pl Fl.Nt1ABLE! EliNift&tt all ipnition sources. H.andlinp 1quipN1nt Must · -bt 9.1'.'~Ul!,dtd tc, prnant sparthp. lLAR'c: SPI.U.Si Eucu&tt U11 huard aru or unprohchd p1ruu11. Mu.r apprtptLlh rupintor and prohcti u c lothJn_g. Shut orr sourct or hat onl5 Jr .nfl tc, do so. DH.a ar.d cont1i~. lr vapor cloud forxs, Nlttr fog M&y bt ustd t~ supprtsJ: Contain run-iirr. RtftoYt wJth · ncuuM tructs· or pu"p to shnpa/nlYapt \ltSSll. Soat up ruJdut wJth u absorbent Ch. \11r1doul!h or othtr nlhb h uttrhl >. Pllct in non-lutlng conhlntrs ror proptr dlspoul. Flush nu with uhr t rtKO\lt tract rtsldut: DJspost or rJuJh solutions as abov,. !SMALL SPILLS! scat up with absorb1nt ~at- . t,rJ&l and place jn non-laatin_g containers: Stal tiphtly and identify contalntr ror proptr disposal. WASTE.DISPOSAL: ~irpos~ or 11u.h in ucord&nct with ·ftdtr&l, shh and loc&l rtpulatlons. ENVIRGl'ENTA!... IHPACT: Spllls should bt rtportad to tht NATICtW.. RESPONSE CENTER and othtr tptnclts as dlctattd by rtgul&tions. -------UIII. SPECIAL HANDLING INFDRHATION------- TRANSPORTATION AND LABELIN~: DOT SHIPPING NAME: ACETONE DOT CLASSrUNrPC: 3, UN 1090, PG II HAZAR:tXXJS MATERIAL ICENTIFICATI~ SYSTEM RATING <HMIS> ' HEALTH~ FIRE 4 REACTIVITY O PERSONNEL PROTECTIVE EQUIPMENT . (Hfl2fleD enn,c: O=r!IhinflL 1= SLICHT, 2 a: noDEtflTE, 3= SteIOUS, '11: SCU(f!( RESPIRATORY PROTECTION: Avoid prolonged or repe1ted bre1thin9 or v,pors. Ust & NIOSH approvtd respir1tor to avoid O\ltT txposurt, whtn 1nticip,ted txposur, excteds occup,tion&l exposure llKits. Use ~ither an 1tNosphere-supplyln9 respir,tor or in 1ir-pvrifyln9 respir1tor for or9tnic vapors. PROTECTIVE CLOTHING: Avoid conttct with eyts. ~,r stfety 9l1sscs or go99les ts tppropriate. Avoid prolon9cd or rtpe1ted contact with stin. ~e,r cheNic&l-resist1nt gloves and other clothing ts required to Ki~iKize cont1ct. ADDITIONAL PROTECTIVE MEASURt.""S: Use explosion-proof venti l1tion ts required to control vtpor concentr,tions Air-dry cont1Kin1ted clothing in l well ventil,ted ,re,. L,under before using. STORAGE AND HANDLING: Stow conhintrs in 1 nrc non-tnrric uu. Keep conhintr closed ,nd wtll idtntif'icd. When tr1nsftrrin.9 product use bonding procedurtS. Do not cut, dri 11, 9rind, wtld or siKiltr oper,tions on or netr tKpty cowt,iners. Keep liquid and v,pors ,way rroK hc1t sp1rts, rl,Kt or other ignition sources. Post NO SHC)(!NG or si1dla.r wunin9 si9nL Vtpors Ht nor111lly huvier thu 1ir ,nd c,n bt 11oved by 1ir currents to surrounding 1rt1s. RI~ TO K?--0-l: All personnel thit K&y possibly co11c in contict wJth this product irt rtquirtd to ~now 1ht location o"f thjs MATERifi. SAFETY DATA SHEET tnd tht inror11,tion conhintd htrtin. Products bting ~old lnd/or rcdlstributtd sh,ll be lcco11p1nitd by 1 HSDS or rurnished within spcciritd tixe li11lts. FOOTNOTES AND ABBREVIATIOHS. NIA= Not ,pplicablt n/1 = inrorN~tion un1viiliblt E/t = Estixated N/D= Not ~tcr11incd -~ "HIS MATERIAL SAFETY DATA SHED is , coxpil,tion or inror11,tion obt,intd froH the HSDS's provided ':J Cr O >In Ch ud Ca } ·s SU pp } i tr S. Th j S CO II p j h. t i On U t i l j ZC S th t NOS f CO n S tr V l t i Vt l ppr O l Ch l S Sh 1t d ~y each supplier. Ccpies of ~teri,l s,rety Oat, Sheets issued by the supplier Kay be obt1ined by : o n h ct i n 9 Cr o w n Ch e 11 i c, l Co r p o r1 t i o n . !1P~3 AC£TOll£ PAGE 3 195'51211 · f:EUISED: MY 15, ins M & W SPRAYDOOTH MANUFACfURING CO., INC. 1!1144 DOWNEY AVENUE PARAMOUNT, CA oonJ (J l 0) liJ0-1635 5-16-93 REVISED UL LISTINGS AND RATINGS FORM AND W SPRAY BOOTHS 1. MOTCP.: ~AKE LEESON MOTOR CO MODEL 120012-120067 2 HP 3 PH 2. SPRAY BuOTH FAN: UL NO E-57948 D.l-YTON MANUFACTURING COMPANY RATED AND LICENSED WITH THE AMCA SEAL MEET STANDARDS 210 AND AMCA STANDARDS 300 SOUND A}R RAT~u ~ITH DCB. REFERRED TO 10-12 WATT. IN ACCORDANCE wlTH THE AMCA STANDARDS 300 TEST SET UP NO 4. TEST MEET A- LEVEL WEIGHTED LW (A) AND WERE CALCULATED AT THE 301 STANDARDS. FAN IS TOTALLY ENCLOSED TUBE AXIAL TYPE, AND BUILT SPECIFICALLY FOR PAINT SPRAY BOOTH APPLICATION. 3. MOTOR STARTER: ALLEN BRADLEY INDUSTRIAL CONTROLS. GENERAL DUTY TYPE NEMA ENCLOSURE TYPE (1) 4. FJ.UORESCENT EXTERIOR LIGHTS: METALUX INDUSTRIAL DUTY LIGHTING INC. 5. GLASS: E-3125 C-37452 1/4" OBS. NO 25 ASW-FED. SPEC NO DD-G451D FEDERAL FIRE STANDARDS APPROVED 6. INTAKE AND EXHAUST FILTERS: FIBAIR PAINT ARRESTORS CLASS (N) TACKYS: CLASS· (A) STANDARDS 4201-4203 7. CAULKING: OAP PRODUCTS MSDS NO DAP/10101 FLAMMABILITY HAZARD 0-MINIMUM FLASH POINT cc:c) NONE UNUSUAL FIRE HAZARDS OR EXPLOSION NONE. 8. SOLENOID AIR VALVE INTERLOCK: R-9118 90-4 GOYEN VALVE CO. 1/2" 230 VOLT SW 60 HZ 9. MICRO LIMIT SWITCH: MH-9011(S) ALLEN BRADLEY RATED AT CLASS ONE DIVISION TWO-OIL TIGHT A-196 M & W SPRA YBOOTH MANUFACTURING CO., INC. 15144 DOWNEY AVENUE PARAMOUNT, CA 90723 (310) 630-1635 FAF2~U F r· o n t F I o w A u t o m o t i v e P a i n t S p r a y b o· o t h ·-M& W Frqnt Flow Auto Paint Spraybooths arc designed.to create a clean, s.:fc 'A .irking environment in which to spray paint ~UIOS. Our'b0ooths arc n0<1u1ar in design, a'nd air make-up and heat can be readil:,-added to ~11..,w thc·ahil)ty to sprny and bake .(n the same booth. . . M ~ W Dooths arc engineered to perform 4 ·111.1jor fum:tions. • rr:r:idc a healthy working environment for the painter. . • 1-r;,rovc the fimsh'qualily by°providing a 0 wcll lit, ventilated area. '• Isolate the application'of haz:udous :md.0ammablc materials. • Cvntrol th~ amount of overspray released [nto t~e atmosphere.· f:0NSTRUCTI0N . • Spraybooths arc constructed of 18 gauge galvanized steel panels c'non· .. · painted),' with 2" pre:punchcd panel flanges. / • Aligned asscQ1bly-_is with nuts nnd bolts,'6" on center. . . •. Bottom channel is hca_yy·duty 14 gauge galvanized steel .. · • Main doors. arc solid welded, tubular framed, for strength and ·durability. Opening ~caSl!fl?S 9' wide x 9' high. • Access man doors arc double walled 36" wide x 84" high. ~ Approved Brixon latchc.~ on all doors. · . .. . Model·, Dimensions Lights FAF24U: ,•, /2J.·x 14'W x 9'H. 10 :·. M & W. Auto Booths arc/ t Long x 14' Wide x 9' Hiih, Our modular design allows for simple upgrades. M& W Auto ~oaths arc built in compliance with OSHA. National Fire Protection As,ocintion, Unifonn Fire Code. and National Electrical Code, as well as Air Quality Control Boards • COMPONENT-PARTS • All clcc1ric:1l components parts arc UL listed. • 2-Tubc light rixturcs arc housed in heavy duty steel dust cov~rs. • Heat tre.1ted light glass for maximum illumination. • Exhaust fan and motor arc rated at 100% efficiency. • Manometer for exhaust liltcr monit~ring. FILTRATIQN • Air flow is'front air flow, front wall intak~. Air enters the booth through' the liltercd drive thru doors, and exhausted through an arrestor chamber located in lhc re:ir of the booth. • Intake filters arc 20" x 20" x 2~ tacky libcrglas.~ filters. Exhau:;l filters arc 20" x 20" x 2" modular, dry type on wire grids. • Exhaust fml i~ tube:ixial in design, with non-sparking bh1de, and driven by u heavy duty motor 11nd fan bells . Fan/Motor . Access Doors Filters (Intake/exhaust) Weight 30",SHp . 20/20 · . ·3,525 FAF24U ·• . Booth Type: Front air flow automotive. .. ' . _Ge~eral Use.: ·compact to fuli' sized autos and medium . sized industrial applications. ·Working Pimensions: . 1rf f:;11 Deep x 14' Wide x 9''Hig~ · ' , . . . ·'· : ' . · ·out;-5ide Dimensions: JZ." Deep x 14'4" Wide x 10' High .. . · l,i'an Data: l' -30" tubeaxial fan wfth non-sparking blade. ' ~M= 1745, CFM ;;·12,980 · Fan Motor Data: 1 -· 2 Hp 3 Ph 208-230/460V 60Hz ODP ., .-.. .. . .. . .. . L~~htfog: 10 -:4' enclo~ed fluorescent.2-tube fix~ures . -· 120V 60Hz (tubes not included) .. '• -. . . · Exhaust ~ilters: I .. pry type fiberglass '.?0" X· 20" On Wir~·grids, '. . . ·. '' ·. (Qty. 20) . ' 1 . ,•, Intake· Filters: Tacky fiberglass 20" x 20" :with self contained frame (Qty. 20). 1 .-. , •' ' . A . . . (1 n/ . •' ?, .. ' .. .. . . ' -0 1\1 & W SPRAYBOOTH MANUFACTURING CO., INC. --V •, 15144 DOWNEY AVENUE PARAMOUNT, CA 90723 .. (JI~) 630-1635 . '· . : . ... -:· .. ··, .. : ·,'·: ... ..... _-; .. ·. ,:· •··.· ·,· • f ••• •• • ·~ • I -~ . ..... s:::.: :-:,.·.···. ,··. It,• ' ' i r ~ ·' ,•' ~ • ho• • •. ~---~ . :· '~ ... .•,' ., .. . , ..... .. ,, ; ; . I • ·.·· . I ! \ i= 0 0 :;: Q) "' ;;.; ;;.; _g CQ "' mu z Iii~ >-~ <( "t;ro "" > Q w V) (I) 0 "" a::: ~ $'. ~ a.. I::! (!) 0-V) ~ > <( 1--V) <( u 8 .... 0 ::r: (I) -2: u~-o w "' -UJ o a z ..; <( I-....I ..0 0 N co ro .!!! z -.,, a.. <( N .._ ::i r--..a Cl NU ::i w <( ., . .... ·. •' ., ,· . I' *" ., • ;_: • : . ~-... J t .. !u ·''-'----~'*~~Iii",. ""'~~::':N~i!W ,= Ifill,~""'-it /tNtl,'.'<lflJ~Jl~l!'J•~c 1:1,~,·1e1ll,IJ.,\~~-~~lk'b.V!i'q1~~B'~I~, .. ~\~ .. 1~~ •• ~ r· 116'0)~~,1~~~ ... I,, .. ,_1,~~···'~ ,J~,.,. .io•1IMlll/llllf1 , ••. 1~';'111111_~~'-!, lt ..... !!111\!1, lj,MII ,,., ~"·::, I ,,~ ,.,.f;I,, ,.,1~\oll.L~ ........ ,-.,.~l;l,IJj~\~"'J/g\~'i\¥111•1 1,!-'\~IN~ll\"~ttel~=lMt'J:~'!ll.flllllJ~/lw ~,~•:,,,~:,--.i1,1 'f!l'~~· ~~-11,_ll'Wlfl•~~"~':II"'"-~" ~__.ljl, J!l,.,_,g•~11,~;g:_,.~i1,,(ljl~Wt's'r/lJ"II'(!; -i~•"Met::f!•• ~ l!~~~.i· <!1'l "' l ,I~ I 1,-lll'!ilrt'l,Wlll'llltlfl ~OOl~1!4l•r.J .. ~.,,...'t:'·~![\6/! ~1,,1 ·~'*"'~~~~--~·~ff' .fl~IJ""'·'·, e~i,: ~,.,'!, LJ , • J , '.JJA ~~ ¥, !¢: -~· -! 7f, -~V --?l¼:/l,~--~:e_. __ !<:!!!'!!'!1>1!! :!!:,!;~,lo/ tt::< UL./¢~~M !:' ~n""' _ --"' .• 11 _, -~"' -~,¢; -!l -·--~ .4 i • • • , e _:, : ___ t;,,w,, _I-L<;: _ 4-.l .... -~--i,~ I .. • i HltZfvf!h-N,t;E'Z.\ I tJ ~10(1-A1,-G I I t<.1- ~Iv€' f./-cfut Ll '-t?M l: ' l · ,----:------:..------;------;,.:::~;;~~~;~_-ll~.·rf_=;_r.:-<;K~~,,~~;;::::::;./~~D,tl;;~.::;,::;:~,.;.,,~::;r;;_:;__, _______ .;_ _________ _: ___________ --:,_---.:_ _____ ..:.....----~~---.... .-1 ·,m.740013.l • (F) 7to,740.lll!I~ / /~ (/_/ -I © 1l I -~, ~ ~ 121 ~---3.· © G I; ~ 1l' ~I ·! w pB:fD~ y F.I i@); --..i! ~ 194 m-~· ~.....B!i 12'! ~11·.'.".:~· 8' tpt "Zlt/l.-DOV~ t..-,,tt€/l-llrl,.... s..--r-o-/lA6·,:f 11~ CAB,~s ,so O)MPLY ..;; tVFP/t ~ j"o f ~CJ~ftP ~f\-\1\)1 'SP~"' Y f:OOTH- \Q 1 ~IOE-A \~'(}e.Ef'X.~11-{16--lt- [of &-/0 t,nt~,+&U 1- I ti I i ~ lib NA-~ vP J1-1R 1 i 1 j),---..---•\@!ll®J -:-:r==:J ~===,_J, ® ~ I lia;q.RE!) STQRA® 131 sl~ ~i QfElg; 133 ,,. j !L....___ ~-~~ ,. -!!.~. ,. ,,.,., ~r. ===r=~-~-=--: = JOI ExlSr.Ns I HR ~ JOO I - 1. I~ 3. 4. 5. 6. 7. 8. 9. 110. -11. ·:q. 13. 14. 15. 16. 17. 18. 19. 120. NOTES Spray booth shall comply wiih NF.PA 33 and UFC 45 Rules. Plans for Automa!jc Fire Suppression.System to be submitted to CFD ~Y qualified and Iicel!sed:engineer. Interlock will be provided between Spray Gun-Air Supply, and ·fan motor •. No smoking signs wm·be posted on spray booth. There·wili be no welding operations or open flame or sparks within 30' of Spray Booth. Minimum of one 4A:40BC Fire Extinguisher will be mounted within 30' of Spray Booth: Filters for Spray'Booth will·be U.L.Listed; Electrical will be Class l, J>iv :Z wjtb no electrical inside booth. Wan: next to location of:proposed spray booth is a 2 hour -fire wall. Booth to use existing electrical service. Exhaust duct terminator point is greater than 30' from property line. Average air flow in spray booth will be minimum 100 FPS during spray operations. Spray booth will be electrically grounded thru electrical conduit/safety di~nnect physical connection to booth. _:- Booth for tenant no jmprovements. .Proce~s-description:-Computer refurbishment including cabinet refinis!ting and hardware upgrades. In use and in storage hazmat material to comply with table 3 Wiring shall comply with section 516 of the 1996 NEC:. . Exhaust ter,mination point minimum 10 ft from any opening of building. Make up air by vented skylights and warehouse doors. Hazardous material storage cabinets comply with NFPA code 30. lf, f::)(.A-\IS-, l)ver.·~ e)(~!) J:>l~'TL'-/ ,01:;)(ie"Jl-,/ oP is..J1'-b1~ ·. --·· ----· · · ·-c-'· - '2.Z--Due >0 eo,jP1bvfl+TIDIV VP-SF~ ,gt:X:1T'&-/ f)vC....T.S ~ /N,t~·ss.reu= 71:> ~/Jb6 •• AVENT DESIGN SPACE Pl»IHINC • tftEIIIOft :lf!?eN :.·~A'JBIT H,IJ Ut:i) f'Lia • t5CO'ooo, ~ 020:n l!lSt,£ l!Q...~ U). L w i- U) )- u) I \_) lU ~ [Q <( ll'5ClllPllON dJ l--() IJ) a WC'-1 3:: " lU <( :::, ---z Z w~ >O <( !!:: ~ -1 w <( '::,L_ \) C) --1 D d) ~ N IS) r-_j N~ "<( \) rr,~1: ~- ,~~ I -, !04 i lLf, . 1 ! I 1® ~ IO<I FLOOR PLAN -FIRST FLOOR ~''--1~}1 1r-is· FLOOR PLAN NOTES I. R&!OVE DCORMD FJU. 1M POOR~ 2. R&.oVi:: EX!STIH6 RU. HEl:S+ti G,ABJJ'iEf a. REI.OG,',TE !:X!STJN6 IIP1'fR l'W.J. GA!llNl:l" TO OF.'OS!rE ~ -4. REl'OVE C"'5JNET AND 5!!«.. 5. ,',l.J<SN PAATlllOI< TO M.U.IOII, 6. G"81):ET ~-FOR mffliOIE EG1JJF!-1E>r.. 'I. EXJ&TJH6 INT6'JOR 61.>,ZJJol& IX FIRE RAll:I> CORRIDOR !55 TO ll: REM0VEr> ,',lb GOAAl!>OI'. TO IJP6!W;>S> TO I t<R G<l!i5!1'!JC,TJO!l ~= ii_U\_-' : • • ,. ~I -•: _: FLOOR PLAN LEGEND 0t,;rE "-''.' 72, ~COO PIK\10:T HO. ~ ~ FOR: IN1ER.IO~ PAR;JT:ON; 2 I/::" M=T~ $11.lli$ ; 24 .. 0£,. >'tfn·i OJ.I; LA":"ER OF s,e· ~ X 6Y'P. sv. E/iGH SIDE. Y'tAll. 1°0 Exre,,tD TO S:~=17 GEl!..lNG. PRO"VIOE D1A!,Q)>:AL 6fV.GlliS o TOP Or J'iA!...!.. FOR LATERAL. SP.PORTO e'o'" OL.1-'AX. JNTieRJOR PA."'TITI0!-1 TO BE l!/0' AFF EX!Sil~ rtAU.5 TO REK6JN DtUl\'N BY-''"'""'""'"-''----- a,E}ll "'"',---------1 PAINT SPRAY BOOTH INSTALLAT1ON BY: ABTECH SYSTEMS COLLISION REPAIR EQUIPMENT 2728 Loker Ave West 14260 Garden Road, Suite 1 lA _. Carlsbad, Ca 92008 Powa , CA 92064 6 l9 7 48-7 446 ~ SCALE: DRAWN BY: DRAWING# NONE ' ' .,, .... . ~-... :-.:}.. DATE: REVISED BY: ._ _______________ .;....,. ______ ~-----::----:-------..,....--:----:-'--'-_;,,_...,...~;._-_... _ _:_ ___ _:_...,;. __ ..:_ ______ __J=~A=u=g=us::t ::24::'::20=0=0=~=::M::i::c:::ha::e::l::R::en=wi=·=ck::::~===2=::0::f::=3=:=~ __ ,. ,. '; I 2· "- ... " &. - I I I ':-' • ID) L I ==== II II II ~@ II ·11 II r=:I!= LIGHT I I LIGHT I ll ~ I LIGHT I TOP VIEW Jo• Tubeaxiol fan w/non sp~rking blade Ph O.D.P. notor [xhaus1 plenun '\.II II II I 1r- II I IL_ I II I II I I If-- II I II I -I II Cxhuust fl lter bunk equiped with 20• X eo• X 2"' --r I __ L I I --I- I I --r I II II II 7---71 I II _J __ _ _II I II I II -1---'--II I II I II 7----11 I II f ibergloss arrestors (Qty. 20) REAR VIEW Brixon safety latch OSHA approved Light to be sealed and gasketed 7 9' -2· < 00) J [xhoust p I enun LIGHT I I 12' -6' <ID> 14' -4' <DD>------ SIDE VIEW Intake filters 20' X 20' X 2' < Qty 20) 9' ~ 14' < ID> 14' -4' < OD> _ FRONT VIEW CONSTRUCTION• (L(CTRICAL• H(CHANICAL- Panels -18 Go. golvonize-d steel. pre-cision punched 6' O.C. (fastened with 1/'4' nuts g, bolts). r l oor Rn I Is -I 4 Go. got van i zed s"tee I precision punche,d 61 a. C. (fast,ned with I /"1 1 nuts L bot ts>. Secur-l"d -i:o floor •/ l/41 drivp pins. 241 0 C. Dr,ve Thru Doors -Single •all 18 Ga galvamz,d s"cerl on 21 'tubular strrl frane Lights -rnctosed e. tube--,.. fluoresce-nt fixtures • i 'th t'nf'rgy rff i c lt>nt ba 11 ast. nounted on 3/16• tenpered 910.ss. CD"ty 10) ~ -2 Hp 3 Ph 20B-230/<460Y O D. F. 1745 R.P,H ~ -_Door t ,n,t S•i'tcht-s _Soteno,d a,r valve L!!,!l -301 tubo>-101 with alynine.m spark proof blade. crH = 12. 190 Hanonrter -Dwyer Hodel 25 air filter gage Door Latches -Bru.on prrssure activatrd type NOT(S, LIGHT DETAIL Light r-1!' to1n1n9 clip -4 tu1Je light f1,-tu.i::..e 0000 \ ~' 'ing fronl' ~ Houn~ 1.12• >-3/8• foon gasket Tenpered gloss PANEL DETAIL 1/4" nut ond bolt G" ~C- Goble ponel ponel PANEL TO GABLE DETAIL 1/4" nut ond bolt G" a.c."' lf.!Coulk 011 seons 14 go. g~lvonized steel\ "-.. j PANEL TO FLOOR RAIL DETAIL f I oor ro I I B ]i-B 1/4' drive pin 24· a. c. Sla-lo PANEL TO PANEL DETAIL Ponels ore precision punched 6' DC ~ /1/4' ___jf-a 1 1a go. / All seoMs to be coulked DOOR DETAIL (top view) nut L bolt 6' QC. golvonized steel ponel --~-1-~ .,,. ,as .. ,,. ''°" •••'\ LID'. 5 5-----on-----5 \----ru 2' tubular door frone / / 18 go. golvonized steel BOOTH TYPE Front Air.Flow Utility SCALE: Booth nonufo.ctured per NfPA 33. UfC 45. NEC 516 '~ RELV-ON SPRAVBOOTH DATE: Accrss Door -Doublr wo.11 18 Go. galvanized s"tirl 36' wldt> .x 84.1 high (Qty. 1> COfVPA NY 11475Stau.an-. PlcaRJvora,C.\IIOl!eO Tel. (5a2) 654-1136 Fax (562) "54-114-4 FILE NAME: FAF24U