HomeMy WebLinkAbout2728 LOKER AVE W; ; CB051755; PermitCity of Carlsbad
1635 Faraday Av Carlsbad, CA 92008
Commercial/Industrial Permit Permit No: CB051755
Building Inspection Request Line (760) 602-2725
Job Address:
Permit Type:
Parcel No:
Valuation:
Occupangy Group:
Project Title:
2728 LOKER AV WEST CBAD
Tl Sub Type:
2090812900 Lot #:
$4,000.00 Construction Type:
Reference #:
PALOMAR TECHNOLOGIES
INSTALL 1 BAY OF PALLET RACKS
COMM
0
NEW
Status:
Applied:
Entered By:
Plan Approved:
Issued:
Inspect Area:
Plan Check#:
Owner:
AL HANDLING
Building Permit $53.49
Add'I Building Permit Fee $0.00
Plan Check $34.77
Add'I Plan Check Fee $0.00
Plan Check Discount $0.00
Strong Motion Fee $1.00
Park Fee $0.00
LFM Fee $0.00
Bridge Fee $0.00
BTD #2 Fee $0.00
BTD #3 Fee $0.00
Renewal Fee $0.00
Add'I Renewal Fee $0.00
Other Building Fee $0.00
Pot. Water Con. Fee $0.00
Meter Size
Add'I Pot. Water Con. Fee $0.00
Reel. Water Con. Fee $0.00
FENTON HG COMPANY
7588 METROPOLITAN DR
SAN DIEGO CA 92108
Meter Size
Add'I Reel. Water Con. Fee
Meter Fee
SDCWAFee
CFO Payoff Fee
PFF (3105540)
PFF(4305540}
License Tax (3104193)
License Tax (4304193)
Traffic Impact Fee (3105541)
Traffic Impact Fee (4305541)
PLUMBING TOTAL
ELECTRICAL TOTAL
MECHANICAL TOTAL
Master Drainage Fee
Sewer Fee
Redev Parking Fee
Additional Fees
TOTAL PERMIT FEES
Total Fees: $89.26 Total Payments To Date: $34.77 Balance Due:
FINAL
ISSUED
05/17/2005
SB
06/28/2005
06/28/2005
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$89.26
$54.49
Inspector: Date: ...&..a;+-"'~-=.--Clearance: _____ _
t approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively
referred to as '1ees/exactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must
follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for
processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack,
review, set aside, void, or annul their imposition.
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity
changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any
fees/exactions of which ou have reviousl been ive a NOTICE simil r to this or as o which he statute of limitations has reviousl otherwise ex ired.
02
.~~.
FOR OFFICE USE ONLY
PLANCHECKN~£ jJ$5_.,,
EST. VAL. L(c>c;>O PERMtT APPLICATION '3 ---r _7 / /""'
CITY OF CARLSBAD BUILDING DEPARTMENT
1635 Faraday Ave., Carlsbad C~ 92008
(2. CONTACT PERSON (if.different from a12Jllicantl' ·
Name Address City State/Zip Telephone#
Designer Name Address City State/Zip
State License# _______ _
# of Bathrooms
Telephone#
[~.'... Wc>m<E~I\WENslrn"cf :=]
Workers' Compensation Declaration: I hereby affirm under penalty of perjury one of the following declarations:
O I have and will maintain a certificate of consent to self-Insure for workers' compensation as provided by Section 3700 of the Labor Code, forthe performance of the work
I have and will maintain worker's compensation, as required by Section 3700 of the labor Code, for the performance of the work for which this rmit is issued. My
~
which this permit is issued.
rker's compensation Ins ce rrier a poll number are: a O
Insurance Company __ "-f..w:p,."-''f-'1<.r-'....,'-------Polley No.~----------Expiration Date ___ v _ _,__i-t~-.::,.....--
(THIS SECTION NEED NOT BE OMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS ($100) OR LESS)
O CERTIFICATE EXEMPTION: I certify that In the performance of the work for Which this permit is issued, I shall not employ any person in any manner so as to
WARNING: Failure se re work rs compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand
dollars($100,000), in addl on the c of compe · n;-damages are provided for In Section 3706 of the Labor Code, Interest and attorney's fees.
SIGNATURE DATE
.,.,_..-...,,..-,_~--------.,..,J ~':-::-:-:=".'"'±-::-:-:-:---:-~==-==---:-:---------·-· _____________ =::J
I hereby affirm that I am exempt the Contractor's License Law for the following reason:
O I, as owner of the property· or my employees with wages as their sole compensation, wm d the work and the structure is not intended or offered for sale (Sec. 7044,
Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or
through his own employees, provided that such Improvements are not Intended or offered for sale. If, however, the building or Improvement is sold within one year of
completion, the owner-builder will have the burden of proving that he did not build or Improve for the purpose of sale).
D I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's
License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's
License Law).
O I am exempt under Section ________ Business and Professions Code for this reason:
1. I personally plan to provide the major labor and materials for construction of the proposed property improvement. O YES O NO
2. I (have/have not) signed an application for a building permit for the proposed work.
3. I have contracted with the following person (firm) to provide the proposed construction (include name I address I phone number I contractors license number):
4. I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name I address I phone number I
/ontractorslicensenumber): -------------------------------------------
6. I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name I address I phone number I type of work):
PROPERTY OWNER SIGNATURE __________________________ DATE __________ _
WHITE: File YELLOW: Applicant PINK: Finance
34.,77
PERMIT APPLICATION
'
GITY OF CARLSBAD BUILDING DEPARTMENT
1635 Faraday Ave., Carlsbad CA 92008
Page 2 of 2
~S~TfO!" FOR'NQN~~NT/A't~on:~ffi\11T$'ONLY · .. -.. ·.·::J
Is the applicant or future building occupant required to submit a business plan, acutely hazardous mate~als registration for or risk management and prevention program under
Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? 0 YES 'II,. NO
Is the applicant or Mure building occupant required to obtain a permit from the air pollution control district or air quality management district? D YES I([ NO
Is the facility to be constructed within 1,000 feet of the outer boundary ofa school site? D YES 'bi NO
IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE
REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT.
~ON~NDINGJU~ENCY ,, ,, _____ :,,, ~. ' -·· .. ··:; ,;:r: •--~~j
I hereby affirm that there is a constru on lending agency for the performance of the work for which this permit is issued (Sec. 3097(1) Civil Code).
LENDER'S NAME _______ ....,.____________ LENDER'S ADDRESS __________________ _
~sf • CANT .l;_B:11 I A O , :.-............-~....,--,,;,;.~ .......... :; .... ; · ~:,-:::J
I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all City
ordinances and State laws relating to building construction. I hereby authorize representatives of the City of Carlsbad to enter upon the above mentioned property for inspection
purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGEMENTS, COSTS AND
EXPENSES WHICH MAY IN ANYWAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT.
OSHA: An OSHA permit is required for excavations of 5'0" deep and demolition or construction of structures over 3 stories in height.
EXPIRATION: Every permit i ed y the building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized
by such permit is not comme d wit in 180 d from the date of such permit or if the building or work authorized by such permit is suspended or abandoned at any time after
the work is commenced for eriod 1 d ( ection 106.4.4 Uniform Building Code). / /
APPLICANT'S SIGNATUR --ldlAl----1'--l~~.:._L-. ________ -"----DATE ~ _ { ·1 _ O 5 t t
WHITE: File YELLOW: Applicant PINK: Finance
CJlY or Carlsbad
· Final Building Inspection
Dept: Building Engineering Planning CMWD St Lite ~
Plan Check #:
Permit#:
Project Name:
CB051755
PALOMAR TECHNOLOGIES
INST'ALL 1 BAY OF PALLET RACKS
Address: 2728 LOKER AV WEST
Contact Person: ANITA Phone: 8584866920
Sewer Dist: CA Water Dist: CA
Date: 08/09/2005
Permit Type: Tl
Sub Type: COMM
Lot: 0
·~~~~;:,;; .. ~~~h= ............. D~a:tie;~:~~: .... ·;7;2~ .. ·:;~·;~~~~ ............... :;~~~~:~~~~:·=·
Inspected
By: __________ Inspected: ______ Approved: ___ Disapproved: __
Inspected Date
By: __________ Inspected: ______ Approved: ___ Disapproved: __ ........................................................................................................................................................... ,
Comments: ------------'-------------------
City of Carlsbad Bldg Inspection Request
For: 08/12/2005
Permit# CB051755
Title: PALOMAR TECHNOLOGIES
Description: INSTALL 1 BAY OF PALLET RACKS
Type: Tl Sub Type: COMM
Job Address: 2728 LOKER AV WEST
Suite: Lot O
Inspector Assignment: PY ---
Phone: 8584866920
Location: Inspector:
APPLICANT COLBRESE MATERIAL HANDLING
Owner:
Remarks: OR YOLANDA AT 213-7372
Total Time:
----
Requested By: ANITA
Entered By: CHRISTINE
CD Description
19 Final Structural ~-om_m_e_nt ________________ _
Associated PCRs/CVs
Inspection History
Date Description Act lnsp Comments
08/09/2005 89 Final Combo CO PY SEE NOTICE ATTACHED
\ \
EsGil Corporation
In (Partnersliip witli government for (}3uilaing Safety
DATE: 6/14/05
JURISDICTION: City of Carlsbad
PLAN CHECK NO.: 05-1755
PROJECT ADDRESS: 2728 Loker Ave. West
SET:I
PROJECT NAME: Storage Racks for Palomar Technologies
d1~~NT jtjRIB.
D PLAN REVIEWER
D FILE
D The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes.
~ The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff.
D The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and. should be corrected and r~submitted for a complete recheck.
D The check list transmitted herewith is for your information. The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck.
D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
D The applicant's copy of the check list has been sent to:
~ Esgil Corporation staff did not ~dvise the applicant that the plan check has been completed.
D Esgil Corporation staff did advise the applicant that th plan c ck has been completed.
Person contacted: Telepho
Date contacted: · ~ (by: )
Mail Telephone Fax In Person
~ REMARKS: 1. Please slip the rack deta· sheet from set I (at building department) into City II set.
2. Fire Department approval is requir . 3. City to field verify the path of travel from the
handicapped parking space to the r: ck area and the bathrooms serving the rack area comply
with all the current disabled acce requirements.
By: David Yao Enclosures:
Esgil Corporation
D GA D MB D EJ D PC 6/7 trnsmtl.dot
\
9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858) 560-1468 + Fax (858) 560-1576
j
--EsGil Corporation
In <Partnersliip witli government for <J3uifaing Safety
DATE: 5/31/05
JURISDICTION: City of Carlsbad
PLAN CHECK NO.: 05-1755
PROJECT ADDRESS: 2728 Loker Ave. West
SET:I
PROJECT NAME: Storage Rack for Palomar Technologies
0 APPL:CANT UL JURIS~
0 PLAN REVIEWER
0 FILE
D The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes.
D The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff.
D The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
~ The check list transmitted herewith is for your information. The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck.
D The applicant's ·copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
~ The applicant's copy of the check list has been sent to:·
D
Colbresr Material Handling 12600 Stowe Dr. #3 Poway, CA 92024
Esgil Corporation staff did not advise the applicant that the plan check has been completed.
Esgil Corporation staff did advise the applicant that the plan check has been completed.
Person fW1taC}99'~· fi · ita (t1M-) Telephone#: (858)486-6920
Date ~-&/JC> _(by: ~'1---') Fax#:
Mail.......---Teiephone Fax In Person
REMARKS:
By: David Yao Enclosures:
Esgil Corporation
D GA D MB D EJ D PC 5/19 trnsmtl.dot
9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858) 560-1468 + Fax (858) 560-1576
\
I ,.., City of Ca;rlsbad 05-1755
5/31/05 .
GENERAL PLAN CORRECTION LIST
JURISDICTION: City of Carlsbad
PROJECT ADDRESS: 2728 Loker Ave. West
DATE PLAN RECEIVED BY
ESGIL CORPORATION: 5/19
REVIEWED BY: David Yao
FOREWORD (PLEASE READ):
PLAN CHECK NO.: 05-1755
DATE REVIEW COMPLETED:
5/31/05
This plan review is limited to the technical requirements contained in the Uniform Building Code,
Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws
regulating energy conservation, noise attenuation and disabled access. This plan review is
based on regulations enforced by the Building Department. You may have other corrections
based on laws and ordinances enforced by the Planning Department, Engineering Department
or other departments.
The following items listed need clarification, modification or change. All items must be satisfied
before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3,
1997 Uniform Building Code, the approval of the plans does not permit the violation of any
state, county or city law.
• To facilitate rechecking, please identify, next to each item, the sheet of the plans upon
which each correction on this sheet has been made and return this sheet with the
revised plans.
• Please indicate here if any changes have been made to the plans that are not a result of
corrections from this list. If there are other changes, please briefly des.cribe them and where
they are located on the plans. Have changes been made not resulting from this list?
D Yes D No
' _,
J City of C3:rlsbad 05-1755
5/31/05 .
1. Please make all corrections on the original tracings, as requested in the correGtion list.
Submit three sets of plans for commercial/industrial projects (two sets of plans for
residential projects). For expeditious processing, corrected sets can be submitted in one of
two ways:
1. Deliver all corrected sets of plans and calculations/reports directly to the City of
Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700.
The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering
and Fire Departments.
2. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320
Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all
remaining sets of plans and calculations/reports directly to the City of Carlsbad Building
Department for routing to their Planning, Engineering and Fire Departments.
NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by
the City Planning, Engineering and Fire Departments until review by EsGil Corporation is
complete.
2. Provide a statement on the Title Sheet of the plans that this project shall comply with
Title 24.
3. Provide a note on the plans indicating if any hazardous materials will be stored and/or
used within the building which exceed the quantities listed in UBC Tables 3-D and 3-E.
4. The tenant space and new qnd/or existing facilities serving the remodeled area must be
accessible to and functional for the physically disabled. Show a path of travel from the
handicapped parking space to the rack area and the bathrooms serving the rack area
comply with all the current disabled access requirements. Title 24, Part 2.
5. Obtain Fire Department approval for groups F, Mand S occupancy storage per UBC
Sections 306.8, 309.8 and 311.8.
6. Recheck all connections on sheet 1 as follows:
a) The rivet bearing capacity is only dtFu = 0.406(0.0747)65 = 2 kips.
b) Provide calculations for all beam to bracket weld capacities per Section 2330
(allowable weld stress is the member thickness times 26 ksi times 1.33, or the
weld stress, whichever is lower).
c) Check the bracket maximum weak axis moment.
7. Provide calculations for the column weak axis bending plus axial for transverse seismic
loading. The axial load is the maximum compression load at the base from vertical plus
seismic overturning. The column moment will probably be maximum for the lateral load
from the base plate to the first diagonal brace (not only to the first horizontal member).
8. The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive,
Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform
the plan review for your project. If you have any questions regarding these plan review
items, please contact David Yao at Esgil Corporation. Thank you.
City of Carlsbad 05-1755
5/31/05' I VALUATION AND PLAN CHECK FEE
JURISDICTION: City of Carlsbad
PREPARED BY: David Yao
PLAN CHECK NO.: 05-1755
DATE: 5/31/05
BUILDING ADDRESS: 2728 Loker Ave. West
BUILDING OCCUPANCY: TYPE OF CONSTRUCTION:
BUILDING AREA Valuation Reg. VALUE
PORTION (Sq.Ft.) Multiplier Mod.
storage rack PER CITY
Air Conditioning
Fire Sprinklers
TOTAL VALUE
Jurisdiction Code CB By Ordinance
Bldg. Permit Fee by Ordinance ..-j
Plan Check Fee by Ordinance ,.. ,
Type of Review: 0 Complete Review D Structural Only
D Repetitive Fee
3Repeats
Comments:
D Other
D · Hourly I Hour *
Esgil Plan Review Fee
($)
4,000
4,000
$53.49j
$34.771
$29.951
Sheet 1 of 1
macvalue.doc
. ~
PLANNINC/ENCINEERINC APPROVALS· ... ·.· .. _
PERMIT NUMBER CB {)y°'-/7 ~·· ... DATE G/zlf/&~ ··
ADDRESS_/_2,,,7~._"'l,._B __ Lo~/iey.,_,,:;,.,;__.-:A-v_e_:_~_~d-_· _-_· __ _
'RESIDINTIAL
RESIDENTIAL .ADDITION MINOR
( < $10,000.00)
.,.. .
ENT
P~ CAMl"O REAL
CARLSBAD COMPANY STORES
VILLAGE' FAIRE
COMPLETE OFFICE BUILDING
OTHER_£~tfv_'-,.;...•l<o.d=~-· ~~.=;...;:-~l==-· _________ _
PLANNER ______ M<-y_;;· ·_:;_;;:==,...---· DATE
DATE s:6¢s::: /
'
BY ........ 9.~ ... 9.!:!A~!A~ ... .
DATE ...... ?::::?:_q~········ ..
SUBJECT. .......... n ........... ~
RACK DESictN & ENGINEERING CO.
412 WEST BROADWAY, SUITE #204
GLENDALE, CA. 91204
TEL:(818)240-3810 FAX:(818)240-3813
STRUCTURAL CALCULATIONS OF STORAGE
RACKS FOR:
PALOMAR TECHNOLOGIES
2728 LOKER AVE. WEST
CARLSBAD, CA.
PER CBC 2001 EDITION
STORAGE RACKS CAPACITY:
2500 # / LEVEL
CALCS. 1 THRU 4
DRAWINGS: RD-9778
SHEET NO •......... J ........... .
JOB NO •....... ~P.-:~.?..?.~ ..
·ey ........ g.~ .. .9.t!AN!AN ... .
DATE ..... :?.'.:":".~.-::-.9.~ ......... :
RACK DESIGN & ENGINEERING CO.
412 WEST BROADWAY, SUITE #204
GLENDALE, CA. 91204 .
SHEET NO •........... ? ........... .
JOB NO ........ ~P.-::-.~.?..?..~ ..
. SUBJECT ......... :, .............. ,. TEL:(818)240-3810 FAX:{818)240-3813
r 144" f
• CX) ,q-
-1t=============1t=~
• (X) ,q-
........ , .... ,. •"'-
FRONT VIE.W
486 BEAM
2500 # / LEVEL
+ 25% IMPACT LOAD
1500 # / BEAM
SEISMIC DESIGN
V= 2.5xCaxl x W
Rx1 •4 woRKING
STRESS
~
:JJ~Lx .t:J
l 2 3/4" l .. ,.
CBC 2001 SEC. 2222
1=1
R=S.6
R=4.4
DOWN AISLE (MOM. CONN.)
CROSS AISLE (BRACED)
. Ca=.44
W=D.L.+L.L.
LOAD PER COLUMN
P= 4x2:-S K =S K
2 COL.
W=. 1 + 5 LL =5. 1 K D.L. ••
y =. 2.5x.44x5.1 = • 7 K
LONGIT. 5.6X1.4
y = 2.5x.44x5.1 = _9 K
TRANS. 4.4X 1 .4
48" r r
SIDE VIEW
lx=2.8
Sx=1
Fy =50 KSI,
LONGIT.
00 -.j-
co -.j-
~ ,q-
~ -.j-
M= 144"x1 .5 K = 27 "K ·a
"K
SR= ~6 · = .9<1
A= 5xWxL3 = .S" < 144 =.8"
384xlx xE 180
SEISMIC
.28 K 6 "K
.21 K 6 "K 10 "K
.14 K 10 "K 13 "K
.07 K 13 "K 15 "K
.7 K 15 ."K
· ·sy ........ _q.'. ... 9.!:!A~!A.~ ... .
DATE ...... ?::::?.:::.q?. ........ :
SUBJECT. .........•.............. ,.
RACK DE$H1N & ENGINEERING CO.
412 WE~T BROADWAY, ~UITE #204
GLENDALE, CA. 91204
TEL:(818)240-3810 FAX:(818)240-3813
SHEET NO •.......... :?. ........... .
JOB NO •....... ~P.-:::~.?..?..~ ..
·coLUMN ANALYSIS
1' ,. t~
J:-C1 [~
Fy=SO KSI
A=.8
Sx=,8
rx =1.2
ry=1.1
COMBINED STRESS RATIO
p + M -5 + 15 -· 1 < 1 33 Pa M0; 18 24 -·
BASE PLATE
15-(5x3") ANCH. TENSION= ---'---<--= 0 6"
ANCHOR SHEAR= ;z_ = .4 K 2
(4).-1/2"¢ HILT! KWIK BOLT 3 ANCHORS
ESR-1385 OR EQUAL (NO INSPECTION REQ'D)
DESIGNED FOR 1 /2 STRESS
.Kl -72 -60 rx -1.2 -
Kl_ 52 _47 ry -. 1.1 -
RACK COLUMNS DESIGNED SUCH THAT IF THE FRONT COL.
IS DAMAGED THE REAR COL. HAS EXT.RA CAPACITY TO SUPPORT
THE FULL LOAD OF THAT BAY, (SEC. 22_22-5)
MOMENT AT BEAM CONNECTION
( 2 PIN CONNECTOR ·o I 7 /16"¢ RIVET 14 14 I A= .1 Fy = 79 KSI
®' _J Va = .1 x79x.4 = 3 K
I I Ma= 3Kx4"x1.33=15"K
~15. CONN.
.. ... :·
Fe=~= 80
( Kl )2
rx
F =F '(1-Fy )= 42 KSI · n y 4F8
Pn :Fn xA = 34 K
p = .J:n_= 18 K a 1.92
5 K
., . .. .. . .
..... . . "'~~-· . . , . .. .. •. . ..... ~ ..
6"
8"
TYP 1/8
~ ~
ASTM A354-79
'BY ........ ~.'. ... 9.!:!AN!A.tL.
DATE ...... ?.-::-::?.:-::9~ ........ ~
SUBJECT. ..........•....•... , ....•.
RACK DESIGN & ENGINEERING Co.
412 WE~T BROADWAY, $UITE #204
GLENDALE, CA. 91204
TEL:(818)240-3810 FAX:(818)240-3813
TRANSVERSE SEISMIC
(OVERTURNING)
Mor= .9Kx2 x192"x.5x1.15 = 198 "K COL
MR = 5.1 Kx42" = 214 "K
NO UPLIFT
LOAD TO DIAGONAL
p : .9 KX2 X .9.Q.. : 2.4 K
COL. 42
Fy=50 KSI
A=.31
rx=.48
Q=.74
L= 56"
CHECK WELDS
Fa= 11.2 KSI
Pa= 3.5 K
1/8" WELD 1.5" LONG EACH SIDE (3" TOTAL)
3x. 125x. 707x70x.3 = 5. 7 K
CHECK SLAB
5000 #
i
.. ·. . ' ~ ..
: : ~ _:.• 4 ..... ~ 4 > ~· -~. . . ~ ",4· ~ . :-: ..
6.5" 7.5"
14" 14-"
27"
TOP LEVEL LOADING
Mor=·1Kx2 x192":38"K COL.
MR :.95 Kx42"= 40 "K
. BOTH SIDES lYP. 1 /S
1 1/2" stf-1-x
~ t=.07"
SEC. A-A
5000 =So'
1000
-v?2Q =27" ·
.5 ..
0
DI
' 0 > / 0
SEC. 8-B
5x144=720 o"
M= ( 7.s )\1 000x J_ x12 = 2344"# 12 2
S= 12x52 = 50 6 .
2~64 = 47 < 1.6 -v'2ooo =72
SHEET NO •......... .1 ........... .
JOB NO ........ ~.!?.:::-.~.?.?.~ ..
,e-" SY'.t ........ g_~: .. 9.r.l~~!AN ... .
DATE .. ,.« ... i ... u1.$ ....... .
SUBJECT. ........................ .
6-tit)
RACK DESIGN & ENGINEERING co.
412 WES'l' BROADWAY. SUITE #204
GLENDALE, dA. 91204.-.
ttL!(818)240-3810 FAX:(818)240---3813
,,;O LU41~S
( ;,; ""'o.. vw"c"t.O :r i . u .,, "'Jfll -..'1 ~-"7,,,;. 2&.Jcr•JJ;l1·1
f"1 A fl,t.t,, 1 .,, • l J£ J d s t, ., .. k.
-, ..
a .... ..,,...,
ft•., · M0wy :,-f I._"..
1-y;ntts,
T~N~ QN~ N9IS3a ~o~~
"!a, f"' r I 1 ".,. , -,c; • ., ::t • .,
SHEET NO ........... L ........ ..
JOB NO •... 8..0, ... j.1.1.I..