HomeMy WebLinkAbout2730 INVERNESS DR; ; CB101447; PermitCity of Carlsbad
1635 Faraday Av Carlsbad, CA 92008
08-05-2010 Miscellaneous Permit Permit No: CB101 447
Buil ding Inspection Request Line (760) 602-2725
Job Address:
Permit Type:
Parcel No:
Valuation:
Reference #:
PC#:
2730 INVERNESS DR CBAD
MISC
2081111800
$4,158.00
Subtype: REROOF Status:
Lot#: 0 Applied:
Entered By:
Plan Approved:
Issued:
Project Title: DAQUI LA RES-3300 SF COMPOSITIO
Inspect Area:
~v,~,o,.J
Applicant:
T R CONSTRUCTION
9847 PASEO MONTRIL 92129
Miscelaneous Fee #1
Miscelaneous Fee #2
Additional Fees
TOTAL PERMIT FEES
PERMIT FEE
Owner:
DAQUILA MICHAEL C&DANA M
2730 INVERNESS DR
CARLSBAD CA 92010
ISSUED
08/05/2010
RMA
08/05/2010
08/05/2010
$121.00
$0.00
$0.00
$121.00
Total Fees: $121:00 Total Payments To Date: $121.00 Balance Due:
Inspector:
Fl NAL APPROVAL
Date: o s/--z,'J /to Clearance: ------
$0.00
NOTICE: Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively
referred to as "fees/exactions.' You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must
follow the protest procedures set fo1th in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for
processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack,
review, set aside. void. or annul their imposition.
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity
changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any
fees/exactions of which vou have oreviouslv been aiven a NOTICE similar to this or as to which the statute of limitations has nrevioustv otherwise exnired.
~' «.~~
·~ CITY OF
CARLSBAD
EXISTING USE
Building Permit Application
1635 Faraday Ave., Garlsbad, CA 92008
760-602-2717 I 2718 / 2719
Fax: 760-602-8558
www.carlsbadca.gov
-:£.nvc..r /k.-~s 77,
PHASE# # OF UNITS # BEOROOMS
PROPOSED USE GARAGE (SF) PATIOS (SF)
Est. Value
Plan Ck. Deposit
10 SWPP
TENANT BUSINESS NAME
/}
DECKS (SF) FIREPLACE AIR CONDITIONING
YESO #_ NDO YES O NO D
CONTACT NAME /If Different Fom App/leant) APPLICANT NAME
ADORE--
CITY
PHONE
EMAIL
ADDRESS -CITY
ARCH/DESIGNER NAME & ADDRESS
STATE
FAX
ADDRESS
ZIP CITY STATE ZIP
PHONE FAX
EMAIL
ZIP
STATELIC. #
OCC. GROUP
FIRE SPRINKLERS
YES O NO 0
(Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to Its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law [Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code} or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500)).
Workers' Compensation Declaration: I hereby affirm under penalty of perjury one of the following declarations:
CJ I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the WOfk for which this pennit is Issued.
J(.1 have and will maintain wo~iocrequired by Section 3700 £~e Labor Code, for the performa~f the wori< for which this pennit is issued. My wori<ers' compensation/,urance trrier and policy
number are: Insurance Co. ~ d', Policy No. CJ' 7 -cx.t)l)'f ?,!:,-Expiration DateO I ,t,} r2. () / /
This section need not be completed If the permit is for one hundred dollars ($100) or less. D Certificate of Exemption: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of
California. WARNING: Failure to secure workers' compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars (&100,000), in
addition to the cost of compensation, damages as provided for In Section 3706 of the Labor code, Interest attorney's fees.
_/#5 CONTRACTOR SIGNATURE ~
I hereby affirm that I am exempt from C011ttactor's Ucense Law for the following reason:
D I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not Intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's
License Law does not apply to an owner of property who builds or improves thereon, and who does such wort( himself or through his own employees, provided that such improvements are not intended or offered for
sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale).
D I, as owner of the property, am exclusively contracting with-licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of
property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law).
D I am exempt under Section Business and Professions Code for this reason:
1. I personally plan to provide the major labor and materials for construction of the proposed property improvement. D Yes D No
2. I (have I have not) signed an application for a building permit for the proposed WOfk.
3. I have contracted with the following person (firm) to provide the proposed construction (include name address/ phone I contractors' license number):
4. I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name I address I phone I contractors' license number):
5. I will provide some of the work, but I have contracted (hired) the following persons to provide the wor1< indicated (include name I address I phone I type of work):
,6$ PROPERTY OWNER SIGNATURE OAGENT DATE
C~MPL~TE THIS SECTION FOR NON-RESIDENTIAL BUILDING PERMITS ONLY
Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the
Presley-Tanner Hazardous Substance Account Act? D Yes D No
Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? D Yes D No
Is the facillty to be constructed within 1,000 feet of the outer boundary of a school site? D Yes D No
IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF
EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT.
I certify that I have read the application and state that the above information Is correct and that the information on the plans Is accurate. I agree to comply with all City ordinances and state laws relat!ng to building construcllon.
I hereby authorize representative of the City of Carlsbad ti enter UJXlfl the above menooned property for i'lspecoon JJJfPC)SeS. I ALSO AGREE TO SA VE, INDEMNIFY AND KEEP HARMLESS THE CllY OF CARLSBAD
AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT.
OSHA: An OSHA pem1it is required k)r excavations <:N~ 5'0' deep and demolition or conslructbn of structures <:N~ 3 sl?ries i1 hei',Jht.
EXPIRATION: Every penn~ issued by the Building Offcial under the prow;ions of this Code shall expire by Imitation and become nun and void i the buidi'lg or v,m authorized by such~ is not coomenced v.flhin
180 days from the date of such pemitor if the buidi'lg orv.00< authorized by such perm~ is spe at any tine after the v.00< is commenced k)r a period of 180 days (Section 106.4.41..kloonn Bultog Code).
~APPLICANT'SSIGNATURE ~ DATE ~ D
REROOFING SUPPLEMENTAL BUILDING PERMIT APPLICATION
1. JOB ADDREss: Z 7 30 .I.nv~, ne., s--s D"
2. TYPE OF BUILDING: RESIDENTIAL x:::-COMMERCIAL. ___ _
3. ROOF SLOPE: RISE~ INCHES IN 12 INCHES
4. NUMBER OF EXISTING ROOF COVERING (CIRCLE ONE) (i)2 3
_ ,rl . I &,}" pP S 1-i->~ s. TYPE oF Ex1sT1NG RooF covERIN~b. sA,1171<-SHEATHING Y< ...
l.{l)Yr I ~ ~
8-10
*6. NEW ROOF MATERIA~l.,;.~/4/11,P CLAssL:±__wEIGHT PER SQ.?~ lb
7. NUMBER OF SQUARES '3 3
8. TRADE NAME(-/i£ [/J( MANUFACTURERW,l&'\s (o,,l'd
9. ROOF SYSTEM LISTING:
UL NO. ______ I.C.C.E.S. Report# _____ _
ASTM _____ _
10. IS THE EXISTING STRUCTURAL~.· SUFFICIENT TO SUSTAIN THE WEIGHT
OF THE PROPOSED ROOF? ~ NO
All roof coverings are required to be CLASS A. Combustible roof coverings of any type or
classification are prohibited.
I understand the following inspections are required:
1. Tear Off/Pre-Inspection prior to install new roof covering
2. Final Inspection
I agree to provide a ladder extending at least 2 rungs above the roof for inspection.
Signature~---~ Date'ts)~/tU
-/ ;?/,
Contractor \L Owner Contractor
Name /J1i /(e._, ~-h:,.. --Ji'
*6. Rolled Roofing, Standard/Lite Tile, Asphalt/Comp fiberglass, Built Up, Other
Page 5 of 5 Rev. 03/09
. m City of Carlsbad Bldg Inspection Request
.
.
For 08/19/2010
Permit# CB101447
Title: DAQUILA RES-3300 SF COMPOSITIO
Description:
Type:MISC Sub Type: REROOF
Job Address:
Suite:
Location:
OWNER
2730 INVERNESS DR
Lot: 0
DAQUILA MICHAEL C&DANA M
Owner: DAQUILA MICHAEL C&DANA M
Remarks:
Total Time:
CD Description Act Comments
19 Final Structural
Comments/Notices/Holds
Associated PCRs/CVs/SWPPPs Original PC#
lns12ection Histo[¥
Date Description Act lnsp Comments
Inspector Assignment: MC ---
Phone: 6195205005
Inspector: _.,_M_l-__
Requested By: TONY
Entered By: CHRISTINE
08/17/2010 15 Roof/Reroof PA MC ENTRY EXTENSION FRAMING ONLY
08/13/2010 15 Roof/Reroof PA MC OK TO SHEATH CRICKET AT NORTH SIDE
08/11/2010 92 Compliance Investigation co MC WORK STOPPED AT ENTRY WAY ROOF EXTENSION, NO PLANS
CALCS APPROVED
08/05/2010 15 Roof/Reroof PA MC MINOR SHEATHING & SHIPLAP REPAIR
i Building Department «'~ ~ CITY OF
CARLSBAD
Unscheduled
Building Inspection.
1635 Faraday Avenue 1 •
carlsbad CA 92008
760-602-2700
DATE: I\ /:,J.J&J VlO INSPECTOR: __ f'-_ll.. ___ _
PERMIT#: U3 Io t'¥1:1 CONTACT:-------
PHONE #: ______ _
JOB ADDRESS: ·2:1~ LiJ..v~cJ.~ss
DESCRIPTION: ___________________ _
CODE
9'Z..
Bldg Inspection Form
DESCRIPTION
lDK futl,J.£.p
Page 1 of 1
ACT
Lo
COMMENTS
~ ~t:ft:13:> M"
EA,lft2..'( \)J,A"'( j.»P
f)(J:e:1-5\ct& NO f'L>~ /
t..A-U' M??A?WP
Rev. 06/09
fh/!(L
City of Carlsbad
1635 Faraday Av Carlsbad, CA 92008
08-11-2010 Plan Check Revision Permit No:PCR10090
Building Inspection Request Line (760) 602-2725
Job Address:
Permit Type:
Parcel No:
Valuation:
Reference #:
PC#:
Project Title:
Applicant:
2730 INVERNESS DR CBAD
PCR
2081111800
$0.00
Lot#: 0
Construction Type: NEW
CB101447
DAQUILA RES-EXTEND COVERED
ROOF AREA OVER ENTRY
Owner:
Status:
Applied:
Entered By:
Plan Approved:
Issued:
Inspect Area:
TR CONSTRUCTION DAQUILA MICHAEL C&DANA M
9847 PASEO MONTRIL 92129
Plan Check Revision Fee
Additional Fees
Total Fees: $60.00
Inspector:
2730 INVERNESS DR
CARLSBAD CA 92010
Total Payments To Date: $60.00 Balance Due:
FINAL APPROVAL
Date: Clearance:
ISSUED
08/11/2010
RMA
08/11/2010
08/11/2010
$60.00
$0.00
$0.00
NOTICE: Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively
referred to as '1ees/exactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must
follow the protest procedures set faith in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for
processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack,
review, set aside, void, or annul their imposition.
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity
changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any
fees/exactions of which vou have oreviouslv been niven a NOTICE similar to this or as to which the statute of limitations has "'reviousl" otherwise exnired.
«~~>,
~ CITY OF
CARLSBAD
PLAN CHECK REVISION
APPLICATION
B-15
Development Services
Building Division
1635 Faraday Avenue
760-602-2719
www.carlsbadca.gov
Plan Check Revision No. p (' j) I Ooq O Original Plan Check NJ C. Ii> IO ) y y I
I Project Address 2-1 'tt) :r:.:J.:e-roc: S~ Dr-Date 8 / I \ ,/ I 0
.
1. ContaciT011t.j O r .MPhl/;A5l-0 .:1/)~ax •. .c· Eml)ailT'(l~fr.,,~ty;,A1~/@,rc,,l<v
} ContactAdtfi"ess 133-:-;, lr,,_ 1vw~<p,.-c-Li ~C~ . Ciry_;:2"-" 'c)12 ZiplL-\ ,17
General Scope of Work Ex +ex,J f::,><,',;j,1 fr; r<t: e .,"-\Je,
Original plans prepared by an architect or engineer, revisions must be signed & stamped by that person.
1 Elements revised:
[Sj" Plans D Calculations D Soils D Energy D Other ___________ _
2 3 4
Describe revisions in detail List page(s) where List revised sheets
~ c> "-+-e,(\ rQ ,.::, v ("';;,-ti nct r,Ve...,r hc,JJC/
1 5' 6" I I J M fr°"-Y Pj)+['-/. J
V
5 Does this revision, in any way, alter the exterior of the project?
6 Does this revision add ANY new floor area(s)? D Yes
each revision is
shown
~ Yes
!i(J No
7 Does this revision affect any fire related issues? D Yes JR] No
8 Is this a complete set? ~ Yes ~ No
'J: -"l'S;gnanue ~~,/,h,4~/
1635 Faraday Avenue, Carlsbad, CA 9~ P:ne: 760-602-27 l 7 / 2718 / 2719
www.carlsbadca.gov
that replace
existinq sheets
D No
Fax: 7 60-602-8558
2X LADDER FRAMING :] FOR PLATE CONNECTION
AT PARALLEL TO TRUSS
DIRECTION ,
~
(E) MFR. TRUSSES @ 24" O.C.
2X STUDS @ 16" O.C.
DBL. TOP PLATE W/
MIN. 48" LAP SPLICE
1X8 T&G SHTG.----~
~?,5 a...,__~les ~ e.o.. ,ro.r\-<U
2X4 STUD WALL WITH DBL. T.PL.
SILID SHEA TH WITH 3/8" PLY
4" O.C. E.N. & 8" O.t. F.N.
k-----SIDING TO MATCH EXISTING
(E) OVERHANG
k-~ I 16d @ 12" O.C.
PLATE NAILING
iE--EXISTING SIDING
2X8 FASCIA BRO.
TO MATCH EXISTING
By
~ ~
~
Al.JG 11 2010
SHEAR TRANSFER ~,"!,,%~'"f;~'ti01'UI. t td?lJ
C) t?Uq Cl] I b/ 'i Lf 7
(E} ROOF SHTG.
5'-6"
~--2X6 RIDGE BRD./BEAM
PLYWOOD GUSSET
DBL 2X4 T.PL & BlM. PLATE Wf.P,4 SlUDS AT 12" O.C. 378" PLY BOTH SIDES 'Ill 10d NAILS AT 4" O.C. E.N. & 4" O.C. F.N.
PREDRILL HOLES BEFOR ATIACHING 1/2" DIA. X 6" LAGS Cf 12" O.C. INTO RIDGE BRO/BEAM
PLYWOOD GUSSET OBJ-2X4 T.PL & BlM. PLATE W/,P,4 SlUDS AT 12" O.C.
37i" PLY BOTH SIDES 'Ill 10d NAILS AT 4" O.C. E. • & 4" O.C. F.N.
4'-o"
PREDRILL HOLES BEFOR ATIACHING · 112" DIA. X 6" 1,AGS Cf 6" O.C. INTO (E} GABLE END FRAMING
b I "'
'-L------EXISTING TRUSSES O 24" O.C.
~ FRAMING CONNECTION
0
IV~!l...-2xs FASaA TO MATCH EXISTING
2X6 NAILER WITH J-1~9 AT 24" O.C. AT (E) lRUSSES
2X6 RAFlERS
~ FRAMING CONNECTION
V
'
r----------------------------------------,
I I
I I
I I
I lli I I I
I ~ I
I ~ 9' PLATE I
I I
I
<$]~
9' PLATE
L-------1------J
$ ;;~~NG ROOF FRAMING PLAN
0;: ~
k1 I
~
~
<$]~
9' PLATE
L-------~-------J
___ __J
•
r----------------------------------------
1
I
I
I
I
I
I
I
I
I
: PLYWOOD I l ( i
I CRICKET
I
IBALOON FRAM( t: :<:/
IWALL EACH
ISIDE
I
I
I
I
I
I
I
I
I
I
L-----______ J
2;{PJLAlJ
$ ~:?!.OSED ROOF FRAMING PLAN
{i]; PLAIT
N
PLYWOOD
CRICKET
~~
9' PLATE I L-------_______ J
2X6 RAFTERS @ 16" O.C.
TO 2X6 RIDGE ATTACH WITH
3-16d TOENAILS
PROVIDE 4' COLLER TE AT
EACH RAFTER
SHEAT ENTIRE OVERHANG EXTENTION
WITH 1X8 T&G SHTG. W/2-16d AT EACH
RAFTER CONNECTION