Loading...
HomeMy WebLinkAbout2734 LOKER AVE W; H; CB950434; Permit4 #73t, B U I L D I N G P E R M I T Permit No: CB950434 09/07/95 13:52 . Project No: A9500625 Page .1 of 1 Development No: Job Address: 2734 LOKER AV WEST Suite: H Permit Type: COMMERCIAL TENANT IMPROVEMENT 1 Parcel No: 4 Lot#: . Valuation: 82,837 09/07/95 0001 01 02 Construction Type: VN C-FRMT 945900 Occupancy Group: B-2 Refèrence#: - Status: ISSUED Description: 4660 SF TI/ 1285 OFFICE Applied: 03/27/95 REMODEL / 3375 WAREHOUSE TO OFFICE . Apr/Issue: 09/07/95 - . . EnteredBy: MDP, Appl/Ownr : LANE, VIRGINIA- 619.431-'7233 2734' LOKER AVE WEST #M. - CARLSBAD, CA. 92008. . .- *** Fees Required *** -. . . •.fAiFeesCoi-lected & Credits - ,. Fees: . 9,86.4O -. ..-. "J t-7/s\ - Adjustments: /.. -.00 - - ToaNCredits: .00 ¼ Total Fees: 9,84-6.00 - Tot-al Paymerrts.:\ . 387.00 - . Balance Dug:* 9,459.00 Fee description .Unp\/Un1t Ext fee Data Building Permit 563.00 Plan Check' 366.004- Strong Motion Fee 17.100 280 - Wa \.(Licenefun1/ J 1/J . 1597.00 (Lic: Tx CFP fUny)'.-./ 1474.00 (TIF Fund) '1 . 902.00 - \TIFFD\FundJC1 b0!1 - - - 952 832.00 Enter Bridge Fee 1-1-2, 0-0 1122.00 *BUILDING TOTAL 9753.00 -. Enter 'Y' for Plumbing ° \3. . . N Enter "Y" for Electric Issue'FeejpJ. -: . 10.00 Y Rernodel/Alter.Per AMP 2-00 : .25 50.00 * ELECTRICAL TOTAL - . 60.00 Enter 'Y' for Mechanical Issue -Fee> . 15.00 Y- Install Furn/Ducts/H&at Pumps . > 2 9.00 18.00 * MECHANICAL TOTAL . . 33.00 . . - . - - I FN LAPPROVAL - •• - . _____ DATE -. -.4 --,• . . .b-RANCE ___ L _______ - H .-- •.. AND -. .. - - ' CITY OF CARLSBAD.. . --.5--. . ......... . 2075 Las Palmas Dr.,, Carlsbad, CA 92009 (619) 438-1161 . C' - o allICAMON City of Carlsbad Building Department 2075 Las Patinas Or., Carlsbad, CA 92009 (619) 438-1161 1. PERJUT TYPE From List I (see back) give code of Permit-Type: 2' i- _:r --------------------------------------------------------- For Residential Projects Only: From List 2 (see back) give Code of Structure-Type: PLAN CHECK NO. 4 ç 3 I .VAL/ 7t°-° -' PLAN CK DEPOSI 1 VALID. BY lLk 3' DATE -zJl1fCC 1222 03/27/95 0001 01 02 C-PRMT 387.00 Net Lass/Gain of Dwelling Units 2. PROJECT INFORMATION FOR OFFICE USE ONLY Address 273'-/ Li) /< ,,L.IJBuilding or Suite No. 4 H- Nearest Cross Street fl/-j) ,.# 4- Al le ,O 02 Energy Calcs 02 Structural Calcs 02 Soils Report 0 1 Addressed Envelope ASSESSOR'S PARCEL ,-,742 7 -6 ?S"/ —7 EXISTING US USE DESCRIPTION OF WORK / ~aA=~ SQ. . 3 5 ES / # OF BEDROOMS # OF BATHROOMS / NAME (last, name first) ADDRESS CITY STATE ZIP CODE DAY TELEPHONE NAME(lastnamefirst)thADDRESS 739 CITY e4€LS/11) STATE (4- ZIP CODE R2 DAY TELEPHONE 3/ — 72-33 PROPERTY OWNER NAME (last name first)44L-S,/ SSij5 L TL) ,, ,9/ b47 cITY // STATE ZIP CODE 37 DAY TELEPHONE Za —72 NTRAUIUR NAME (last name first) '77 1) ADDRESS CITY STATE ZIP CODE DAY TELEPHONE STATE UC. # UCENSE CLASS CITY BUSINESS DC. # VtSi.,1N ttt INIUVW J. astname1Irst) ,z,ve,V T //5fr) CITY 5,L4 e,A,i STATE (4 ZIP CODE -Li) q DAY TELEPHONE 47'_q1/g/5TATE DC. # workers compensation ijeciaration: I nereny airirm mat i nave a certiricate or consent to seir-insure issuea Dy tne IJirector or inciustnai Relations, or a certificate of Workers' Compensation Insurance by an admitted insurer, or an exact copy or duplicate thereof certified by the Director of the insurer thereof filed with the Building Inspection Department (Section 3800, Lab. C). INSURANCE COMPANY POLICY NO. EXPIRATION DATE Certificate of Exemption: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. SIGNATURE DATE 8. OWNER-BUIU)ER DECLARATION Owner-Builder Declaration: I hereby affirm that I am exempt from the Contractor's License Law for the following reason: 0 1, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden V of proving that he did not build or improve for the purpose of sale.). I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). I am exempt under Section Business and Professions Code for this reason: (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law (Chapter 9, ommencing with Section 7000 of Division 3 of the Business and Professions Code) or that he is eempt therefrom, and the basis for t Ileged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the iplicant toa civil penalty of not m an five hundred dollars [$500]). J SIGNATURE DATE 2/L7/?5 Is the applicant or futqfft building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program uWder Sections 255055533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? YES Is the applicant or future building occupt required to obtain a permit from the air pollution control district or air quality management district? O YES 'NO Is the facility to be constructed within 1,gQdfeet of the outer boundary of a school site? 0 YES P'NO IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED AFTER JULY 1; 1989 UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTHICF. ereby affirm that there is a construction lending agency for the performance or the work for which this permit is issued (Sec 3097(1) Civil Code). LENDER'S NAME LENDER'S ADDRESS 10. APPUCANI CERI1FICMION I certify that I have read the application and state that the above information is correct. I agree to comply with all City ordinances and State laws relating to building construction. I hereby authorize representatives of the City of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE 10 SAVE INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABilITIES, JUDGMENTS, CX)STS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF lifE GRANTING OF THIS PERMIT. OSHA An OSHA permit is required for excavations over 5'O" deep and demolition or construction of structures over 3 stories in height. Expiration. Every permit issued by the Building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such rmit is not commenced within 365 dayqrom the date of such permit or if the building or work authorized by such permit is suspended or abanjop'ed at any time after the work is ç m ced for a period of 180 days (Section 303(d) Uniform Buildipg.Code)/, APPLICANT'S SIGNATURE /7/ # '1 j DATE: ./.2 7/ ,5 PINK: Finance 0 ;' • j:7ç3.. - .SEWER PERMIT 09/07/95 13:52 l ' Permit No: SE950029 Page 1 of I. .•,. t. Bldg PlanCk#: C895434 Job Address: 2734 LOKER AV WEST. Suite: H Permit Type: SEWER.—'OFFICE/WAREHOUSE' Parcel No: 3562 09/07/95 0001 01 02 Description: 4660 SF TI / 1285 OFFICE ,. isson, REMODEL / 3375 WAREHOUSE TO OFFICE Applied 03/30/95 Apr/Issue: 09/07/95 Permite: LANE, VIRGINIA 619 431-7233,-,--' Expired: 2734 LOKER AVE WEST #M . Prepared By: MDP CARLSBAD, CA.--, 92008 ------------------------- ---------- * * * Fees Required -* ** *Fee ! Credit's-* * * Fees: 2 1 258' yN Adjustments: :O0 r .00 Total Fees: 2,258.00 . . .00 Fee ±! ± ±c?e'6nit "-;Ext fee Data Sewer Fee Enter Sewer'EDUs Ii, f A, a k— SEWER TOTAL ::! Eq H G : INCORPOR ED 1952 EThAPPROVATfl \s DTE_-\ CLEARANCE CITY OF CARLSBAD - -' 2075 Las Palmas Dr., Carlsbad, CA 92009 (619) 438-1161 S CITY OF CARLSBAD INSPECTION REQUEST PERNIT# CB950434 FOR 12/06/95 INSPECTOR AREA TP DESCRIPTION: 4660 SF TI / 1285 OFFICE PLANCK# CB950434 REMODEL / 3375 WAREHOUSE TO OFFICE 0CC GRP B-2 TYPE: CTI . CONSTR. TYPE VN JOB ADDRESS: 2734 LOKER AV WEST STE:. H LOT: APPLICANT: LANE, VIRGINIA . PHONE: 619 431-7233 CONTRACTOR: PHONE: OWNER: PHONE: REMARKS: MW/JERRY/929-9510 INSPECTOR ___________________ SPECIAL INSTRUCT: TOTAL TIME: --RELATED PERMITS-- PERNIT# ' TYPE' STATUS . .. SE950029 .SWOW ISSUED . AS950057 ASTI ISSUED CD LVL DESCRIPTION • . ' ACT COMMENTS 19 ST Final. Structural 'XP 29 .PL Final Plumbing .• S _____________________________ 39 EL Final Electrical 49 ME Final Mechanical - . S ***** INSPECTION HISTORY ***** DATE DESCRIPTION ACT INSP - COMMENTS 112195 Final Combo • CO TP • SEE JOB CARD 101995 Frame/Steel/Bolting/Welding AP TP T-BAR GRID 101995 Rough Electric AP TP CEILING LITES 101995 Rough/Ducts/Dampers AP TP DUCTS 101695 Frame/Steel/Bolting/Welding CO TP NEED APR PLANS 092195, Interior Lath/Drywall AP TP 091995 Insulation AP TP. EXT WALLS FURRED 091895 Frame/Steel/Bolting/Welding AP TP FRAME CORR ONE SIDE 091895 Rough Electric CO TP • BACK TO BACK BOXES N/BND SCR 091495 Frame/Steel/Bolting/Welding PA TP. ONE SIDE WALLS ND BRACE/SCREW 091495 Rough Electric -• AP TP ' WALLS ~1 ESGIL CORPORATION 9320 CHESAPEAKE DR., SUITE 208 SAN DIEGO, CA 92123 (619) 560-1468 DATE: June 16, 1995 . JURISDICTION: Carlsbad PLAN/IEWER U FILE PLAN CHECK NO.: 95-434 SET: II PROJECT ADDRESS: 2734 Loker Ave. W PROJECT NAME: Office T. I. for Fish & Wildlife Services ,The plans transmitted herewith have been"côrrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. S The applicant's copy 'of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: Esgil Corporation staff did not advise the applicant that the plan check has been completed. Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: '• ' Date' contacted: (by: r') Telephone #: LII REMARKS: ' By: Abe Doliente Enclosures: Esgil Corporation S S Ij GA R CM fl PC 6/8/95 5 trnsmtl.dot ESGIL CORPORATION 9320 CHESAPEAKE DR., SUITE 208 SAN DIEGO, CA 92123 - (619) 560-1468 DATE: May 16, 1995 U APPLICANT JURISDICTIO JURISDICTION: Carlsbad 0 PtANR VIEWER D FILE, PLAN CHECK NO.: 95-434 SET: I PROJECT ADDRESS: 2734 Loker Ave. W. PROJECT NAME: Office T. I. for Fish & Wildlife Services The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. - The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. j The applicant's copy of the check listis enclosed for the jurisdiction to forward to the applicant contact person. 0 The applicant's copy of the check list has been sent to: Lisa Avent 9807 Caminito Cuadro, San Diego, CA 92129 • Esgil Corporation staff did not advise th applicant that the plan check has been completed. Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Date contacted: (by: ) Telephone #: - REMARKS: 0 By Abe Doliente Enclosures Esgil Corporation . GA • CM 0 PC 5/9/95 0 trnsmtldot Carlsbad 95-434 May 16, 1995 PLAN REVIEW CORRECTION LIST TENANT IMPROVEMENTS Ii H PLAN CHECK NO.: 95-434 OCCUPANCY: B-2 TYPE OF CONSTRUCTION: V-N 11 ALLOWABLE FLOOR AREA: Existing JURISDICTION: Carlsbad USE: Offices ACTUAL AREA: 4355 SF (New) • 1285 (Existing) V STORIES: 1 V SPRINKLERS?: Yes REMARKS: DATE PLANS RECEIVED BY JURISDICTION: DATE INITIAL PLAN REVIEW COMPLETED: May 16, 1995 HEIGHT: V V • OCCUPANT LOAD: 57 V DATE PLANS RECEIVED BY ESGIL CORPORATION: 5/9/95 PLAN REVIEWER: Abe Doliente FOREWORD (PLEASE READ): . ii This "plan review is limited to the technical requirements contained in the Uniform Building Code,: Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review Js based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required 'prior to the issuance of a building permit. Code sections cited are based on the 1991 UBC. The following items listed need clarification, modification or change. All items must be satisfied before the plans will, be in conformance with the cited codes and regulations. Per Sec. 303 (c), 1991 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. - To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet number, specification section. etc. Be sure to enclose-the marked up list when you submit the revised plans. V. LIST NO. 40, TENANT IMPROVEMENTS WITHOUT SPECIFIC ENERGY DATA OR POLICY SUPPLEMENTS (1991UBC) tiforw.dot Carlsbad 95-434 May 16, 1995 - 1. Please make all corrections on the original tracings and submit two new sets of prints, to: Esgil Corporation, 9320 Chesapeake Drive, Suite #208, San Diego, CA 92123, (619) 560-1468 or to the jurisdiction's building department. 2. Each sheet of the plans must be signed by the person responsible for their preparation, even though there are no structural changes. Business and Professions Code. 3. UBC Section 304 requires the Building Official to determine the total value of all construction work proposed under this permit. The value shall include all finish work, painting, roofing, electrical, plumbing, heating, air conditioning, elevator, fire extinguishing systems and any other permanent equipment. Please provide a signed copy of the designer's or contractor's construction cost estimate of all work proposed. 4. Indicate the use of all spaces adjacent to the area being remodeled or improved. 5. Corridors serving 30 or more occupants shall have walls and ceilings of one-hour construction. Show compliance or clearly show on plans which of the following exceptions has been satisfied: Corridors greater than 30 feet wide when the occupants have an exit independent from the corridor. Exterior sides of exterior exit balconies. Corridor walls and ceilingsneed not be of fire-resistive construction within office spaces having an occupant load of 100 or less when the entire story in which the space is located is equipped with an automatic sprinkler system throughout and smoke detectors are installed within the corridor in accordance with their listing. d) Within office spaces occupied by a single tenant, partial height partitions which form corridors and which do not exceed 6 feet in height need not be V fire resistive, provided they are constructed in accordance with Section 1705 and are not more than three fourths of the floor-to-ceiling height. Section 3305 (g). 6. If non-rated corridors are used per Section 3305(g), Exc. 5, provide a reference to the corridors on the floor plan, noting: V Corridors are non-rated per Section 3305(g), Exception 5. Smoke detectors shall be maximum 30' on center. C) Power supply shall be dedicated branch circuit. Circuit disconnecting means shall be accessible only to authorized personnel and shall be clearly marked FIRE ALARM CIRCUIT CONTROL, with a lock-on device. 4 7. If a tenant space utilizes Section 3305(g), Exception 5, then that tenant space V shall be separated from adjacent spaces by a demising wall constructed as for a one-hour corridor wall. Carlsbad 95-434 May 16, 1995 One-hour fire-rated corridors shall have interior door openings protected by tight- fitting smoke and draft control assemblies rated 20 minutes, except openings in interior walls of exterior exit balconies. Doors shall be maintained self-closing or be automatic-closing by action of a smoke detector per Section 4306(b). Doors shall be gasketed to provide a smoke and draft seal where the door meets the stop on sides and top. Section 3305(h). Show rated corridors; lobbies, reception or foyers cross-hatched on the floor plans. Provide a complete architectural section of the corridor, or exterior exit balcony, showing all fire-resistive materials and details of construction for all floors, walls, ceiling and all penetrations. Section 3305(g) II. Show the location of fire dampers. Provide fire dampers at duct penetrations of fire-rated occupancy and area separations, shafts and corridor ceilings. Combination fire/smoke dampers are required at duct penetrations of rated corridor walls. Section 43060). 12. New provisions in Chapter 43 of the 1991 UBC require special treatment of penetrations at fire-resistive assemblies. Provide typical details on the plans showing how the fire-resistive integrity will be maintained at the following conditions (Include the manufacturers' names and ICBO numbers (or equal) for any sealant): THROUGH-PENETRATIONS (through the entire assembly): Fire-resistive bearing walls and/or walls requiring protected openings shall have penetrations protected with through-penetration fire stops having an F-rating, T-rating or complying with UBC Standard 43-1, depending on their locations, sizes and combustibility. Fire resistive floor/ceiling assemblies shall have penetrations protected with through-penetration fire stops having and F-rating, T-rating or complying with UBC Standard 43-1, depending on their sizes, combustibility and whether the penetrations are in walls above. MEMBRANE-PENETRATIONS (through only one side of an assembly): Fire-resistive walls (whether bearing or not and whether requiring fire protected openings or not) shall have penetrations protected with membrane-penetration fire stops having an F-rating or complying with UBC Standard 43-1, depending on their size and combustibility. Limited steel electrical outlet boxes (not exceeding 16 sq. in., nor more than 100 sq. in. for any 100 sq. ft. of wall) require no protection. Fire-resistive ceilings shall have no penetrations, except for noncombustible sprinkler pipes and steel electrical outlet boxes as described above. NOTE: The plans should indicate the various fire-stop ratings required for all penetrations. Carlsbad 95-434 May 16, 1995 Provide a note on the plans stating "Penetrations of fire-resistive walls, floor-- ceilings and roof-ceilings shall be protected as required in UBC Sections 4304 and 4305". The tenant space and new and/or existing facilities serving the remodeled area must be accessible to and functional for the physically disabled. See the attached correction sheet. Title 24, Part 2. ELECTRICAL PLAN REVIEW JURISDICTION: Carlsbad DATE: 5/15/95 PLAN REVIEW NUMBER :95-434 I PLAN REVIEWER :Chuck Mendenhall 15. Specify the wire type (AL or CU) and insulation (i.e. THWN). NEC 310. Specify the wiring method you intend to use for this project (i.e., EMT, Metal Flex, NMC etc). Provide receptacle(s) within 25 feet of HVAC equipment. UMC 509. Provide multiple switch light controls so that the lighting can be reduced by one half in a uniform pattern. The switches must be located within sight of the lights which they control. (CCR) Title 24, Sec 131 a-b . Show exit signs on the lighting plan(s) at all required exits and specify them as being self-luminous or having a second source of power ( battery or generator). This is required when two exits are required per the UBC. UBC 3314 and NEC .700-16. Note: If you have any questions regarding this electrical plan review list please contact the plan reviewer listed above at (619) 560-1468. To speed the review process, note on this list ( or a copy) where the corrected items have been addressed on the plans. • 4 Carlsbad 95-434 May 16, 1995 PLUMBING, MECHANICAL AND ENERGY CORRECTIONS JURISDICTION: Carlsbad DATE: 5/18/95 PLAN REVIEW NUMBER: 95-434 SET: I PLAN REVIEWER: Glen Adamek . MECHANICAL (UNIFORM MECHANICAL CODE) Detail ladder access to roof mounted HVAC equipment. ENERGY CONSERVATION NOTE: Plans submitted after January 1, 1993 must comply with the new energy standards. On the plans clearly show the wall and roof insulation locations, thickness, and R-values, as per the energy design. Show bi-level lighting controls as per Title 24, Part 6, Section 131(b). Correct the allowed lighting on the LTG-2 form. The complete building: office can not be used for part of a conditioned. building. Please use the Area Category Method. Show the Corridors, Restrooms, and Support Areas; and Dining on the LTG-2 form (Occupancy). . - The lighting in existing non-conditioned rest rooms now being conditioned is not shown in the energy design. Please correct. - The MECH-2 for office-zone 2 (page 16 of 22 of COMPLY 24) shows HVAC unit is oversized. Please correct the energy design to show compliance. On the plans clearly showthe light fixture wattages and number of light tubes per fixture to comply with the energy design. The corrected, completed and signed ENV-1, LTG-1, and MECH-1 form's must be imprinted on the plans. • 0 0 • • . . . • - Note: If you have any questions regarding this plan review list please contact Glen Adamek at (619) 560-1468. To speed the review process, note on this list (or a 0 copy) where the corrected items have been addressed on the plans. Carlsbad 95-434 May 16, 1995 MISCELLANEOUS To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please indicate: Yes El NO The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 619/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Abe Doliente at Esgil Corporation. Thank you. DEPARTMENT OF STATE ARCHITECTURE-NON RESIDENTIAL TITLE 24 DISABLED ACCESS REQUIREMENTS SCOPE: The following disabled access items are taken from the 1991 edition of California Administrative Code Title 24, applicable as of April 1, 1994. Per section 110 B, all publicly and privately funded public accommodations and commercial facilities shall be accessible to persons with physical disabilities as follows: Any building, structure, facility, complex, or improved area, or portions thereof, which are used by the general public. Any sanitary facilities which are made available for the public, clients, or employees in such accommodations or facilities. Any curb or sidewalk intended for public use that is constructed with private funds. All existing accommodations when alterations, structural repairs or additions are made to such accommodations. GENERAL: To assure that barrier-free design is incorporated in all buildings, facilities, site work and other improvements, these standards apply to all additions, alterations and structural repairs. These standards incorporate the requirements covered in Title Il and Ill of the Americans with Disabilities Act of 1990. Items preceded with an asterisk (*) are examples of changes that have occurred since the previous regulations. . NOTE: All Figures and Tables referenced in this checklist are printed in California Administrative Code, Title 24. '1 Carlsbad 95-434 May 16, 1995 SITE ACCESSIBILITY Site development and grading shall be designed to provide access to all entrances and exterior ground floor exits, and access to normal paths of travel, and where necessary to provide access, shall incorporate pedestrian ramps, curb ramps, etc. *When more than one building or facility is located on a site, accessible routes of travel shall be provided between buildings and accessible site facilities. At every primary public entrance and at every major function along or leading to an accessible route of travel, there shall be a sign displaying the international symbol of accessibility. Signs shall indicate the direction to accessible building entrances and facilities. Where stairways occur outside a building, see section 3306(q) for requirements. . DISABLED ACCESS PARKING SPACES *The required number of accessible parking spaces in new facilities *(or in existing facilities where a change of occupancy occurs) is as follows per Table 31A: *1 for each 25 spaces up to 100 total spaces. I additional space for each 50 spaces for between 101 and 200 total spaces. C) 1 additional space for each 100 spaces for between 201 and 500 total spaces. For between 501 and 1000 total spaces, a minimum of 2% of the total number of spaces is required. For greater than 1000 spaces, 20 plus 1 for each additional 100 spaces. If total number of spaces is less than 5, one shall be 14'0" wide and line to provide a 90' parking area and 50" loading and unloading area. There is no requirement that this space be identified or reserved for the exclusive use by persons with disabilities. 6. *Accessible spaces shall be located as follows, per section 3107A(a)1: On the shortest possible route to an accessible entrance when serving a particular building. On the shortest route of travel to an accessible entrance of a parking facility. C) Dispersed and located closest to accessible entrances where buildings have multiple accessible entrances with adjacent parking. Note: This section does not apply to existing facilities where local ordinances preclude requirements unless a change of occupancy occurs. 7. Single spaces shall be 140" wide and outlined to provide a 9'0" parking area and a 50" loading and unloading area on the passenger side of the vehicle. When more than one space is provided, in lieu of providing a 14'0".space for each space, two spaces can be provided within a 230" area with a 5'0' loading zone between each 90" wide space. Each space is to be a minimum of 180" in depth. See section 3107A(b)1. NOTE: See Figures 31-18A, 31-18B and 31-18C. 8. A bumper or curb shall be provided and located at each space to prevent encroachment of cars into the required width of walkways per section 3107A(b)3. 9. The maximum slope of parking surfaces in any direction shall not exceed 1/4I per foot (2.083%) per section 3107.1(b)4. The maximum slope at the passenger loading zone shall not exceed 2%. 10. Parking spaces shall be identified by a reflectorized sign permanently posted immediately adjacent to and visible from each space, consisting of a profile view of a wheelchair with occupant in white on dark blue background. The sign shall not be smaller than 70 square inches in area and, when in a path of travel, shall be posted at a minimum height of 80" from the bottom of the sign to parking space finished grade. Signs may also be centered on the wall of the interior end of the parking space at a minimum height of 36" from the parking space finished grade, ground or sidewalk. Spaces Carlsbad 95-434 May 16, 1995 complying with section 3107A(b)2 shall have an additional sign "Van-Accessible" mounted below the symbol of accessibility per section 3107A(c). In addition, each accessible space is required to be marked with the international symbol of accessibility. An additional sign shall also be posted in a conspicuous place at each entrance to off street parking facilities, or immediately adjacent to and visible from each stall or space. The sign shall be not less than 17" by 22" with lettering not less than I" in height. Per section 3107A(c) required wording is as- follows: "Unauthorized vehicles parked in designated accessible spaces not displaying distinguishing placards or license plates issued for persons with disabilities may be towed away at owner's expense. Towed vehicles may be reclaimed at or by telephoning Space(s) shall be located so that disabled persons are not compelled to wheel or walk behind parked cars other than their own per section 3107A(b)3. *A minimum of one in every 8 accessible spaces shall be served by an access aisle 96" minimum width and shall be designated van accessible per section 3107A(b)2. All such spaces may be grouped on one level of a parking structure. CURB RAMPS NOTE: See Figures 31-19A through 31-22. Curb ramps shall be constructed at each corner of street intersections and where a pedestrian way crosses a curb per section 3106A(e). Curb ramps shall be a minimum of 48" wide with a maximum slope of 1:12 (8.33%), per sections 3106A(e)2 and 3106A(e)5. The lower end of each curb ramp shall have a 1/2l lip be beveled at 45 degrees. *The landing at the top of the curb shall be level and 48' minimum depth for the entire width of the curb ramp or the slope of the fanned or flared sides shall not exceed 1:8 (12.5%), per section 3106A(e)4. The surface of all curb ramps and its flared sides shall be slip resistant and contrasting from the adjacent sidewalk finish per section 3106A(e)6. All curb ramps shall have a grooved border .12" wide at the level surface of the sidewalk along the top and each side approximately 3/4l on center per section 3106(e)7. *Detectable warnings extending the full width and depth of the curb ramp inside the grooved border if the slope is between 1:15 (6.66%) and 1:20 (5%), per section 3106A(e)8. This shall consist of raised truncated domes with a diameter of 0.9" at the base tapering to 0.45" at the top. Spacing shall be 2.35" center-to-center. NOTE: See Figure 31-23. Locate curb ramps to prevent obstruction by blocked cars per section 31 06A(e)9. The slope of adjacent surfaces, including street and gutter, within 4 feet of ramps shall be limited to a maximum of 1:20 (5%), per section 3106A(e). WALKS AND SIDEWALKS 21: Walks sloping greater than 1:20 (5%) must comply with the ramp requirements of section 3307 per section 3324(c). Carlsbad 95-434 May 16, 1995 Walks shall be 48" minimum in width and have slip resistant surfaces. The maximum cross slope shall not exceed 1/4I per foot per section 3324(a).3 If the enforcing agency finds that an unreasonable hardship exists, then the maximum cross slope may be increased to a maximumof '2 per foot for distances not to exceed 20 feet. Abrupt level changes shall not exceed '2 along any accessible route. When changes do occur, they shall be beveled with a slope of no greater than 1:2. Level changes of 1/4I or less may be vertical. Note: If level changes exceed 1/2",they must comply with requirements of curb ramps. At each gate or door, a 60" x 60" level area is required when the gate or door swings toward the walk per section 3324(e). Walks shall extend 24" minimum to the side of the strike edge of a door or gate that swings toward the walk. NOTE: See Figure 33-2. Provide 80" minimum headroom from all walkway surfaces to any obstruction per section 3325(b). At walks with continuous gradients, level areas at least 50" long at intervals of 400 feet are required per section 3324(f). Grating openings are to be limited to a maximum of '2 in the direction of travel per section 3324(b). Provide 36" wide detectable warning material at the boundary between walkways and vehicular ways. Material shall comply with criteria of section 3325A(c)1, per section 3325(e). more than one route is provided, all routes shall be made accessible per section 3103A(i)2. . PEDESTRIAN RAMPS A path of travel with a slope exceeding 1:20(5%) shall be considered a ramp per section 3307(a.1). Handrails are required to be provided at each side of ramps. The maximum allowable slope for accessible ramps is 1:12 (8.33%), per section 3307(e.1)1. *provide the least possible slope for all ramps. The maximum cross slope at walks and sidewalks shall not exceed 1/4" /4 per foot (2%) per section 3324(a)3. If the enforcing agency finds that an unreasonable hardship exists, then the maximum cross slope may be increased to a maximum of I per foot (4%) for distances not to exceed 20 feet. Ramp surfaces shall be slip resistant, per section 3307(g). Ramps shall have a minimum width of 48 inches. Ramps serving primary entrances to building having an occupant load of 300 or more shall have a minimum clear width of 60 inches. Section 3307(b. 1)2. Landings are required at the top and bottom of all ramps, per section 3307(d.1). The bottom landing shall be a minimum of 72" in the direction of travel and the top landing shall be a minimum of 60" x 60". . A 60" intermediate landing is required at maximum elevation changes of 30". A 72" landing is required at direction changes exceeding 30 degrees per section 3307(d.1)6. When a door swings over the top landing, the minimum depth of the landing shall equal to the door width, plus 42", per section 3307(d.1). Carlsbad 95-434 May 16, 1995 39. Strike edge distances to door shall be 24' at exterior ramps (and 18" at interior ramps), per section 3307(d.1). 40. *When the slope of ramps exceeds 1:20 (5%), handrails are required at each side, per section 3307(e.1), 41. Handrails shall be 11/4 to 11/2 in cross section and placed a minimum of 11/2 from walls, per section 3307(e.1). 42. Per section 3307(e.1), handrails shall meet the following requirements: Be continuous. . *Located 34".to 38" in height above the ramp surface. C) Have 12" extensions beyond the top and bottom. d) Ends shall be returned. 43. If ramp exceeds 100" in length (and ramp is not bounded by walls, curbs or wheel guides shall be. provided, per section 3307(h. 1). 44. Wall surfaces, adjacent to handrails, shall be free of sharp or abrasive elements, (i.e., no stucco), per section 3307(e.1). ENTRANCES AND CIRCULATION 45. *fl entrances and exterior ground level exits shall be made accessible, per section 3301(h). 46. *When a building, or portion of a building, is required to be accessible (or adaptable), an accessible route of travel shall be provided to all portions of the building, to accessible building entrances and between the building and the public way. See section 3103A(i)2. . DOORS ,. 47. Per section 3304(f), every required passage door shall have a minimum 32" clear width. 48. Where a pair of doors is utilized, at least one of the doors shall provide a clear unobstructed opening width of 32". 49. Door hardware shall be of the lever or push type and mounted 30" to 44" above the floor, Oer section 3304(c.1). 50. Per section 3304(i.1),regardless of the occupant load, there shall be a level floor or landing on each side of the door. The floor or landing shall not be more than I lower than the threshold of the doorway. Note: An exception is permitted for exterior landings, which may slope up to 1/4"per foot (2%) in any direction, for surface drainage, per section 413. 51. Per section 3304(c.1), all hand-activated door opening hardware shall meet the following requirements: Shall be centered between 30" and 44" above the floor. Latching and locking doors 'that are in a path of travel shall be operated with a single effort by lever type hardware, panic bars,, push-pull activating bars or other hardware designed to provide passage without the ability to grasp the opening hardware. C) Locked doors shall exit in the direction of travel. 52. . The lower 10" of all doors shall be smooth and uninterrupted to allow the door to be opened by a * wheelchair footrest A,ithout creating 'a trap or hazardous condition. Narrow frame doors may use a 10" high smooth panel on the push side of the door. . Carlsbad 95-434 May 16, 1995 53. The width of the level area, on the side to which a door (or gate) swings, shall be as follows per section 3304(11): Extend 24" past the strike edge of the door for exterior applications. Etend 18" past the strike edge of the door for interior conditions. C) *Extend 12" past the strike edge on the push side if door has latch and closer. 54. Maximum effort to operate doors shall not exceed 81/2 pounds for exterior doors and 5 pounds for interior doors. Such push or pull effort shall be applied at right angles to hinged doors and at the center plane for sliding doors. Where fire doors are required, the maximum effort to operate the door may be increased to 15 pounds. See section 3304(i.2)1. . SANITARY FACILITIES 55. Sanitary facilities that serve buildings, facilities, or portions of buildings or facilities that are required to be accessible to persons with disabilities, shall be made accessible unless the enforcing agency determines that compliance with these standards would create an unreasonable hardship and equivalent facilitation is provided per section 3105A(b)1. 56. See exceptions to section 3105A(b)1. regarding the requirements for equivalent facilitation under unreasonable hardship. Accessible sanitary facilities must be usable by a physically disabled person within a reasonable distance of accessible areas. Equivalent facilitation would provide for either a lateral or front transfer toilet stall. C) NOTE: See Figure 31-1C. d) Doors shall have a clear and unobstructed opening of at least 30". 57. Per. section 3105A(b)1.A, where separate facilities are provided for nondisabled persons of each sex, separate facilities shall be provided for the disabled persons of each sex as well. Where unisex facilities are provided for nondisabled/disabled persons, such unisex facilities shall be provided for the disabled. 58. Per section 3105A(b)1.C., passageways leading to sanitary facilities shall have clear access widths as specified in chapter 33. All doorways shall have a minimum 32" clear opening and a level and clear area for a minimum depth of 60" in the direction of the door swing and 44" where the door swings away from the level and clear area. In addition, all strike edge clearance dimensions are required to be met. 59. Doorways leading to men's sanitary facilities shall be identified by an equilateral triangle 1/4"thick with edges 12" long and a vortex pointing upward. Women's facilities shall be identified by a circle, 1/4" /4 thick, 12" in diameter. Unisex facilities shall be identified by a circle with a triangle superimposed on the circle and within the 12" diameter. The required symbols shall be centered on the door at a height of 60". *See section 3105A(b)1.D. See 3105A(e)10 for additional signage. . SINGLE ACCOMMODATION FACILITIES 60. *As per section 3105A(b)3.B., there shall be a sufficient space in the toilet room for a wheelchair measuring 30" x 48" to enter the room and permit the door to close. No door shall be permitted to encroach into this space. There shall be a clear floor space at least 60" in diameter, or a T-shaped space as shown in Figure 31-12 (a) and (b). Doors are not permitted to encroach into this space. 61. The water closet shall be located in a space which provides a minimum 28" clear space from a fixture or 32" clear space from a wall on one side. A minimum of 48" clear space shall be provided in front of the water closet. Carlsbad 95-434 May 16, 1995 62. For bathrooms serving hotel guest rooms, see section 1214(d). . RESTROOM FIXTURES AND ACCESSORIES 63. In new construction, water closets in accessible restrooms shall meet the following requirements per section 5-1502: The height of the water closet seat shall be between 17" and 19". The controls shall be operable with one hand and shall not require tight grasping, pinching or twisting of the wrist. .c) The controls for flush valves shall be mounted on the side of the toilet area and be no more than 44" above the floor. The force required to activate the controls shall be no greater than 5 pounds of force. In alterations where the existing fixture is less than 15" high, a 3" seat shall be permitted. 64. Lavatories shall comply with the following requirements per section 3105A(b)4.A., 3105A(h)4. and 5- 1504: A minimum of 30" x 48" clear space shall be provided in front of the lavatory for forward approach. The clear space may include knee and toe space beneath the fixture. The clear space beneath lavatories shall be a minimum of 29" high x 30" wide x 8" deep at the top and 9" high x 30" wide and 17" deep at the bottom from the front of the fixture. The maximum height of the counter top shall be 34" C) All hot water and drain pipes under the lavatory shall be insulated. The faucet controls and operating mechanism shall be. of the type' not requiring tight grasping, pinching or twisting of the wrist and have an operating force of not greater than 5 pounds. If self-closing valves are used, they shall remain open for at least 10 seconds. 65. Showers and shower compartments shall comply with the requirements of sections 5-1505 and 3105A (b)5. and 6: Compartments shall be 42" in width between wall surfaces and 48" in depth with an entrance opening of 36" minimum. NOTE: See Figure 31-2A. C) Grab bars shall comply with section 3105A(b)3.C.(ii), (iii) and (iv). They shall be located on walls adjacent to and opposite the seat and mounted 33" to 36" above the shower floor. NOTE: See Figure 31-2A. When a threshold or recessed drop is used, it shall be a maximum of '2 in height and shall be beveled or sloped at an angle of not more than 45 degrees from the horizontal. The shower floor shall slope toward the rear of the compartment to a drain located within 6" of the rear wall. Maximum slope of the floor shall be '2" per foot in any direction. The floor surface shall be of Carborundum, grit faced tile or of material providing equivalent slip resistance. A folding seat located on the wall opposite the controls' and mounted 18" above the floor shall be provided. NOTE: See Figure 31-2A. The soapdish shall be located on the control wall at a maximum height of 40" above the shower floor. Showers in all occupancies shall be finished as specified in section 3105A(b)5 to a height of ' not less than 70" above the drain inlet. I) Where no separate shower compartment is provided, the shower shall be located in a • corner with L-shaped grab bars extending along two adjacent walls with a folding seat adjacent to the shower controls. ' • m) A flexible hand-held shower unit, with a hose at least 60" long shall be provided with head mounting height of 48" A.F.F. Two wall-mounted heads may be installed in lieu of the hand- held unit in areas subject to excessive vandalism per section 5-1505. Carlsbad 95-434 May 16, 1995 66. Grab bars shall comply with the following per section 3105A(b)3.C.: Grab bars shall be located on each side or one side and the back of the physically disabled accessible toilet stall or compartment. They shall be securely attached 33" above the floor and parallel except where a tank-type toilet is used which obstructs placement at 33", the gab bar may be installed as high as 36". Grab bars at the side shall be located 15" to 161/2 (Ll") from- the center line of the water closet stool and be at least 42" long with the front end positioned 24" in front of the stool. Total length of bars at the back shall not be less than 36". C) The diameter or width of the grab bar gripping surface shall be 1/4 to 1 /2 or the shape shall provide an equivalent gripping surface. If mounted adjacent to a wall, the space between the wall and the grab bar shall be 1 /2 . d) See section 3105A(b)3.C.(iii) for structural strength requirements. NOTE: See Figures 31-1A, 311B, 31-IC, 31-2A, 31-9A and 31-913. 67. Where towel, sanitary napkins, waste disposal and other similar dispensing and disposal fixtures are provided, at least one of each type shall be located with all operable parts within 40' of the floor. Mirrors shall be mounted with the bottom edge no higher than 40" above the floor. 68. Toilet tissue dispensers shall be located on the wall within 12" of the front edge of the toilet seat per section 3105A(b)4.C. . DRINKING FOUNTAINS 69. Where water fountains are provided they shall comply with section 3105A(d)1: . TELEPHONES 70. Where public telephones, or public pay phones, are provided they shall comply with the requirements of section 3105A(d)2: Carlsbad 95-434 May 16, 1995 VALUATION AND PLAN CHECK FEE JURISDICTION: Carlsbad PLAN CHECK NO.: 95-434 PREPARED BY: Abe Doliente DATE: May 16, 1995 BUILDING ADDRESS: 2734 Loker Ave. W BUILDING OCCUPANCY: B-2 * TYPE OF CONSTRUCTION: V-N BUILDING PORTION BUILDING AREA VALUATION VALUE 11 (sq.ft.) MULTIPLIER ($) Office T. I. 4355 SF 26.00 113,490 Air Conditioning Fire Sprinklers TOTAL VALUE 113,490 Building Permit Fee: * Plan Check Fee: • • - * * Comments: ESGIL FEE = 0.80 X 447.53 = $ 358.02 $ 688.50 • • * $ 47.53 Sheet I of I valuefee.dot ........... City'' of Carlsbad- BUILDING PLANCHECK CHECKLIST DATE: PLANCHECK NO. CB q ,' BUILDINb A'DDRESS: Z ?3/ .'; PROJECT DESCRIPTION: '3' JI'f ASSESSOR's PARCEL NUMBER: 24 -c?/7-z9 . EST.VALUE 9c2 _.•_).,'. -- -. .. .j•..'• - - ENGINEERING . -•.. , -. - DEPARTMENT DENIAL • -: APPROVAL. Please see the attached report L of deficiencies marked • 3, The item you have submitted for review has been with (21 Make necessary corrections to plans or approved. The approval is based on plans, information, specifications for compliance with applicable codes and and/or specifications provided in your submittal; therefore standards. Submit corrected plans and/or specifications any changes to these Items after this date, including field to this office for review. ' y modifications must be reviewed by this office to insure continued conformance with applicable codes. Please. ' • ' : . review carefully all comments attached, as failure to - comply with instructions in this report can result in By: Date: suspension of permit to build - L.J A Right-of Way permit is required prior to construction BtJ - Date' ' of Ahe following improvements - By: Date - . - ,.. .: "-- - '' ' :- , - . ..• . . . ' . . ' ' :- ATTACHMENTS . • ENGINEERING DEPT. CONTACT.PERSON a. , . ' • :- ', El Dedication Application Dedication Checklist [J Improvement Application 0 Improvement Checklist ' -' - -. ' : NAME: -: --: -r-, - - 'y- - . U Future Improvement Agreement .... .• ' -. -. City of Carlsbad 0 Gradin Permit Application - ADDRESS 2075 Las Palmas Dr Carlsbad CA 92009 U Grading Submittal Checklist ' PHONE (619) 438-1161 Ext.- 0 Right of Way Permit Application - -4 5- of 5-_4 & - 1 4 4 Right Way Permit Submittal Checklist and Information Sheet - 0 Sewer Fee Information Sheet - • -. A-4 . 4 - .. ' P \DOCS\CHKLST\BP000I FRM ' ' -, ?, -- . ••_i•_ ._7• • . REV 05/11/94 2075 Las Palmas Dr. • Ca,sad, • CA 92009-1576. (61 9) 4381161 FAX (619) 438-0894 -4 BUILDING PLANCHECK CHECKLIST /2ndv/ SITEPLAN Is 3rd../ IJ 0 0 1. Provide a fully dimensioned site plan drawn to scale. Show: North Arrow D. Property Lines Easements Existing & Proposed Structures E. Easements /10 Existing Street Improvements F. Right-of-Way Width & Adjacent Streets 0, 2. Show on site plan: / . Drainage Patterns C. Existing Topography . Existing & Proposed Slopes 0 0 3. Include note: "Surface water to be directed away from the building foundation at a 2% - gradient for no less than 5' or 2/3 the distance to the property line (whichever is less).".. [Per 1985 UBC 2907(d)5]. / On graded sites, the top of any exterior foundation shall extend above the elevation of the Street gutter at point of discharge or the inlet of an approved drainage device / a minimum of 12 inches plus two percent (per 1990 UBC 2907(d)5.). L1 0 0 4. Include on title sheet * Site address . Assessor's Parcel Number . • Legal Description For commercial/industrial buildings and tenant improvement projects, include: Total building square footage with the square footage for each different use, existing sewer permits showing square footage of different uses (manufacturing, warehouse, office, • etc.) previously approved. F EXISTING PERMIT NUMBER DESCRIPTION • . . S S • .• / '5 . • • .5. ,• • S. •. S - P:\D0CS\CHKLSI\0P0001.FRM • • • Page 1 of 4 . - REV 05/11/94 - • . S.. BUILDING PLANCHECK CHECKLIST DISCRETIONARY APPROVAL COMPLIANCE liht',/ 2nd,/ 3rd./ )V4' 0 0 5. Project does not comply with the following Engineering Conditions of approval for I Project No. Conditions were complied with by: ' Date:__________________ DEDICATION REQUIREMENTS $ 0 0 6. Dedication for all Street Rights-of-Way adjacent to the building site. and any storm 4' drain or utility easements 'on the building site is required for all new buildings and for remodels with a value at or exceeding $______________ -pursuant to Code Section 18.40.030. ' Dedication required as follows Attached please find an application form and submittal checklist for the dedication process. Provide the completed application form and the requirements on the checklist at the time of resubmittal Dedication completed by Date IMPROVEMENT REQUIREMENTS O 0 ' 0 7a. All needed public improvements upon and. adjacent to the building site must be constructed at time of building construction whenever the value of the construction exceeds $ -pursuant to Code Section 18.40.040. ' Public improvements required as follows ( Please have a registered Civil Engineer prepare appropriate improvement plans and submit them together with the requirements on the attached checklist for a separate plancheck process through the Engineering Department. Improvement plans must be approved, appropriate securities posted and fees paid prior to issuance of permit. Attached please find an application 'form and submittal checklist for the public improvements requirements. Provide the completed application form and the requirements on the checklist at the time of resubmittal Improvement Plans signed by Date P:\D005\CHKLSr8POOO1.FRM Page 2of4 1 - BUILDING PLANCHECK CHECKLIST 1 SW 2fldv1 3rdv1 .0 U 0 7b. Construction of the public improvements may be deferred pursuant to code Section 18.40. Please submit a recent property title report or current grant deed on the property and processing fee of $_ so we may prepare the necessary Future Improvement Agreement. This agreement must be signed, notarized and approved by the City prior to issuance of a Building Permit. - Future' public improvements required as follows:_______________________________ Improvement Plans signed by: Date:___________ 0 0 0 7c. Enclosed please find your Future Improvement Agreement. Please return signed and notarized Agreement to the Engineering Department. .1/ Future Improvement Agreement completed by:.______________________________ Date:__________________ . . 12' 0 0 7d. No Public Improvements required. SPECIAL NOTE: Damaged or defective improvements found adjacent to building site must be repaired to the sátisfactioh of the City Inspector prior to occupancy. - ' GRADING PERMIT REQUIREMENTS The conditions that invoke the 'need for a grading permit are found in Section 11.06.030 of the Municipal Code. . O 0 0 8a. Inadequateinformation available on Site Plan to make a determination on grading requirements. Include accurate grading quantities (cut, fill import, export). 0 0 0 8b. Grading Permit required. A separate grading plan prepared by a registered Civil Engineer must be Submitted together with the completed application form attached. - - NOTE: The Grading Permit must be issued and rough grading approval obtained prior -. to issuance of a Building Permit. . 0 Grading Inspector sign off by: Date: D" "0 0 8c. No Grading Permit required. 0 • BUILDING PLANCHECK CHECKLIST MISCELLANEOUS PERMITS tv1 2ndv' 3rd./ 0 0 9. A RIGHT-OF-WAY PERMIT is required to do work in City Right-of-Way and/or private work adjacent to the public Right-of-Way. Types of work include, but are not limited to: Street improvements, trees, driveways, tieing into public storm drain, sewer and water utilities. Right-of-Way permit required for A separate Right-of-Way permit issued by the Engineering Department is required for the following: • / .• . / 0 0 10. A SEWER PERMIT is required concurrent with the building permit issuance. The fee -. is noted in the fees section on the following page. 0 0 ii. INDUSTRIAL WASTE PERMIT is required. Applicant must complete Industrial Waste Permit Application Form and submit for City approval prior to-issuance of a j'll • Permit. 1 0 • tfr ( Industrial waste permit accepted by: • Date: t • - •• P \DOCS\CHKLST\BP000I FRM Page 4 of 4 REV 05/11/94 =s =s =$ ri ENGINEERING DEPARTMENT ENGINEERING REVIEW SECTION FEE CALCULATION WORKSHEET 0 Estimate based on unconfirmed information from applicant. )Calculation based on building plancheck plan submittal. - Address: ::2734Z //cf4 Bldg. Permit No. Prepared by: Date: Checked by: Date:_____________________ EDUCALCULATIONS: List types and square footages for all uses. Types of Use O(—'c6 Sq. Ft/4Jes' 337 EDUs C,;i- 1s-E 33Zc Y'c -- Total EDU's: ADTCALCULATIONS: List types and square footages for all uses. Types of Use: 0 +F1 C C Sq. Ft/Units: 33?6_'600ô ADT's:______________________ Ci1 ,7 c..)l1.fE 337 %, - Total ADT's FEESREQUIRED: PUBLIC FACILITIES FEE REQUIRED 0 YES NO (See Building Department for amount) WITHIN CFD: DYES (no bridge & thoroughfare fee, )I NO reduced TrafficImpact Fee) 1 PARK-IN-LIEU FEE PARK AREA:_________ FEE/UNIT: - X NO. UNITS:______ )i?I2.TRAFFIC IMPACT FEE AOl's/UNITS: .57 X FEE/ADT: 3i BRIDGE AND THOROUGHFARE FEE ADT's/UNITS: .57 FACILITIES MANAGEMENT FEE ' SO.FT.:________ SEWER FEE PERMIT No. BENEFIT AREA: DRAINAGE FEES PLDA _: HIGH fLOW______ f ACRES: X FEE/AC:________ SEWER LATERAL ($2,500 DEPOSIT) \I7Ia tAIAWb ccc X FEE/ADT: ZONE:_________ X FEE/SQ.FT.:_________ EDU's: EDU's: / -e X FEE/EDU:________ DRAINAGE BASIN:______ X FEE/EDU:______ U. VVI• U I L.I_. EDU's: / X FEE/EDU: 2rôo 21 TOTAL OF ABOVE FEES*: $ *NOTE: This calculation sheet is NOT a complete list of all fees which may be due. Dedications and Improvements may also be required with Building Permits. P:\D0CS\MISF0RMS\BP0002.FRM - REV 01/04/95 PLANNING G1EQU1&r Plan Check No. g- 3q Address 273tf Lok- Are. S Planner DAVID RICK Phone 438-1161 ext. 4328 • (Name) APN: ;4c:c/. ol • Type of Project and Use Zone 17'-i Facilities Management Zone S ) CFD60cleut (II property in, complete SPECIAL TAX CALCULATION WORKSHEET provided by Building Department.) / 1 Legend 0 0 - Item Complete . Item Incomplete Needs your action 1, 2, 3 Number in circle indicates plancheck number where deficiency was identified / Required: DATE OF COMPLETION: Compliance with conditions of approval? If not, state conditions which require action. Conditions of Approval '• - 0 C3 •Disaetionaiy, Action Required: YES - NO APPROVALJR.ESO. NO. DATE: PROJECT NO. OTHER RELATED CASES: - \ Cbinpliance with conditions of approval? If not, state conditions which require action. Conditions of Approval Cahfomia Coastal Commission Permit Required YES - NO DATE OF APPROVAL San Diego Coast. District, 3111 Camino Del Rio North, Suite 200, San Diego, CA. 92108-1725 (619) 521-8036 0 • • • Compliance with conditions of approval? If not, state conditions which require action Conditions of Approval In Clusionary Hong Feerequired: YES ___ NO Y (Effective date of [nclusionary Housing Ordinance. May 2i-,1993.) / Site PIan 0 Provide a fully dimensioned site plan drawn to scale. Show: North arrow, property lines, easements, existing and proposed structures, streets, existing street improvements, right-of-way width, dimensioned setbacks and existing topographical lines 0 0 Provide legal description of property, and assessor's parcel number. Zoning ) Setbacks: Front: Required Shown Int. Side: Required Shown Street Side: Required Shown Rear: Required Shown 0 0 0 2. Lot coverage: Required Shown 0 0 0 3 Height: Required Shown / 4r(y 't t c4c 4. Parking: Spaces Required Shown Guest Spaces Required Shown 0 0 0 Additional Comments OK TO ISSUE AND ENTERED APPROVAL INTO COMPR DATE __________ PLNCK.FRM City of Carlsbad 95065 Fire Department Bureau of Prevention Plan Review: Requirements Category: Building Plan Check Date of Report:- Friday, May 19, 1995 Reviewed by: Contact Name Lisa Avent Address 2734 LokerAvW#M City, State Carlsbad CA 92008 Bldg, Dept No. 95-434 Planning No. Job Name Fish & Wildlife Job Address 2734 Lokér Ste. or Bldg. No. Approved - The item you have submitted for review has been approved. The approval is based on plans; information and/or specifications provided in your submittal; therefore any changes to these items after this date, including field modifica- tions, must be reviewed by this office to insure continued conformance with applicable codes. Please review carefully all comments attached, asr failure to comply with instructions in this report can result in suspension of permit to construct or install improvements. 0 Disapproved - Please see the attached report of deficiencies. Please make corrections to plans or specifications necessary to indicate compliance with applicable codes and standards. Submit corrected plans and/or specifications to this office for review. For Fire Department Use Only Review 1st 2nd 3rd Other Agency ID CFD.Job# 95065 File# S 2560 Orion Way Carlsbad, California 92008 (619) 931-2121