Loading...
HomeMy WebLinkAbout2735 CAZADERO DR; ; CB020642; Permit06-11-2007 Job Address Permit Type Parcel No Valuation Occupancy Group # Dwelling Units Bedrooms Project Title Applicant WEATHERLYPHIL 3323 PAR DR 92054 City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Residential Permit Permit Mo CB020642 Building Inspection Request Line (760) 602-2725 2735 CAZADERO DR CBAD RESDNTL Sub Type 2154001000 Lot# $63,036 00 Construction Type Reference # 0 Structure Type 0 Bathrooms MIHOLICH RESIDENCE 612 SF ADDITION RAD 0 NEW Status Applied Entered By Plan Approved Issued Inspect Area Orig PC# Plan Check* 173/01/2002 MDP Owner MIHOLICH FAMILY TRUST 12-14- 2735 CAZADERO DR CARLSBAD CA 92009 Building Permit Add! Building Permit Fee Plan Check Addl Plan Check Fee Plan Check Discount Strong Motion Fee Park in Lieu Fee Park Fee LFM Fee Bridge Fee Other Bridge Fee BTD #2 Fee BTD #3 Fee Renewal Fee Add'l Renewal Fee Other Building Fee HMP Fee Pot Water Con Fee Meter Size Add'l Pot Water Con Fee Reel Water Con Fee $40796 Meter Size $0 00 Add'l Reel Water Con Fee $265 17 Meter Fee $0 00 SDCWA Fee SO 00 CFD Payoff Fee $630 PFF (3105540) $0 00 PFF (4305540) $0 00 License Tax (3104193) $0 00 License Tax (4304193) $0 00 Traffic Impact Fee (3105541) $0 00 Traffic Impact Fee (4305541) $0 00 Sidewalk Fee $0 00 PLUMBING TOTAL SO 00 ELECTRICAL TOTAL $0 00 MECHANICAL TOTAL $0 00 Housing Impact Fee 99 Housing InLieu Fee $0 00 Housing Credit Fee Master Drainage Fee SO 00 Sewer Fee $0 00 Additional Fees TOTAL PERMIT FEES SO 00 SO 00 $000 $000 $000 $000 $000 $000 $000 $000 SO 00 $000 $000 $000 $000 $000 $000 $000so oo $000 $679 43 Total Fees $679 43 Total Payments To Date $265 17 Balance Doe:$41426 Inspector FINAL APPROVAL Date Clearance _ NOTICE Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exactions" You have 90 days from the date this permit was issued to protest imposition of these fees/exactions If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing m accordance with Carlsbad Municipal Code Section 3 32 030 Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired 1^503 PERMIT APPLICATION CITY OF CARLSBAD BUILDING DEPARTMENT 1635 Faraday Ave , Carlsbad, CA 92008 FOR OFFICE USE ONLY PLAN CHECK NO EST VAL Plan Ck Deposit Validated By Date 2024 03/01/0: 0002 01 Address (include Bldg/Suite #) i— ' ~7 ^•^" &r\'ZAt. Legal Description Assessor's Parcel # ._ „ ,/„ Description of Work Business Name (at this address) fM^F"1- ^^\ 17")&?££) />>£ — *-**~*r i.u./ - 1 Lot Mo Subdivision Name/Number Existing Use SQ FT #of Stories Unit No Phase No Proposed Use # of Bedrooms Total # of units >M tf of Bathrooms Name State/Zip Telephone #Fax # Name "4 IfePRO'PERTY'OWNER Address ;L Name Address State/Z'P Telephone L'i. (Sec 7031 5 Business and Professions Code Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor s License Law (Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code] or that he is exempt therefrom, and the basis for the alleged exemption Any violation of Section 7031 5 by any applicant for a permit subjects the applicant to a civil penalty of not moie than five hundred dollars l$5001) Name State License # Address License Class City State/Zip City Business License # Telephone # Designer Name State License # Address City State/Zip Telephone Workers' Compensation Declaration I hereby affirm under penalty of perjury one of the following declarations fj I have and will maintain a certificate of consent to self-insure for workers compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued f_J I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued My worker's compensation insurance carrier and policy number are Insurance Company _ Policy No _ Expiration Date _ _ (THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS [$1001 OR LESS) O CERTIFICATE OF EXEMPTION I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California WARNING Failure to secure workers' compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars ($100,000), in addition to the cost of compensation, damages as provided for in Section 3706 of the Labor code interest and attorney s fees SIGNATURE DATE ______ DECLARATION "v ,) jj -. . ". "' _" T V" " I " ' ," ' , .'L' r, t ''"£•" V' ' ', , ' " I',' >"i' '"j" I I hereby affirm that I am exempt from the Contractor's License Law for the following reason Q I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec 7044, Business and Professions Code The Contractor's License Law does not apply to an owner of property who bLilds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale If, however, the building or improvement is sold within one year of completion, trie owner-builder will have the burden of proving that he did not build or improve for the purpose of sale) Q I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec 7044, Business and Professions Code The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law) C] I am exempt under Section _ Business and Professions Code for this reason 1 I personally plan to provide the major labor and materials for construction of the proposed property improvement Q YES O^O 2 I (have / have not) signed an application for a building permit for the proposed work 3 I have contracted with the following person (firm) to provide the proposed construction (include name / address / phone number / contractors license number) 4 I plan to provide portions of the work, but ! have hired the following person to coordinate, supervise and provide the major work (include name / address / phone number / contractors license number) 5 I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone number / type of work) PROPERTY OWNER SIGNATURE DATE ,COMP(LETEtiTHIS|SECTldN FOR NQN-RES/D£NTIALSBUILD\NG PERMITS ONLY * '" < ! ! , ;L »' ( ( ! I, ,, ,, '• , s '/ ! M * K 8 !y ^ | s f s \ \s ts ,r j,^ ' LVJ'd { ,' Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? Q YES £] NO Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district7 Q YES O NO Is the facility to be constructed within 1 ,000 feet of the outer boundary of a school site7 Q YES £] NO IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec 3097(i) Civil Code) LENDER S NAME LENDER S ADDRESS _ __ _ __ I certify that 1 have read the application and state that the above information is correct and that the information on the plans is accurate 1 agree to comply with all City ordinances and State laws relating to building construction I hereby authorize representatives of the CitV of Carlsbad to enter upon the above mentioned property for inspection purposes I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT OSHA An OSHA permit is required for excavations over 5'0" deep and demolition or construction of structures over 3 stories in height EXPIRATION Every permit issued by the building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced~tor a oewocj qf 180 day_sJSection 106 4 4 Uniform Building Code) APPLICANT S SIGNATURE DATE PINK Finance 01/02/2003 WEATHERLYPHIL 3323 PAR DR92054 Re Application Date 03/01/2002 0 00 00 Plan Check # CB020642 Address 2735 CAZADERO DR Expiration Date 03/01/2003 0 00 00 Permit Type RESDNTL Description MIHOLICH RESIDENCE 612 SF ADDITION You applied to have your plans checked on the date noted above To dale, the related building permit has not been obtained The original plan review application will expire as no building permit has been issued Plans submitted and not retrieved from the building department prior to the plan check expiration date noted above will be destroyed The provisions of sections 304 (d) of the Uniform Building Code state "Section 304 9d) Expiration of Plan Review Applications for which no permit is issued within one year following the date of application shall expire by limitation, and plans and other data submitted for review may thereafter be returned to the applicant or destroyed by the Building Official In order to renew action on an application after expiration, the applicant shall resubmit plans and pay a new plan review fee " In order to provide better service, please indicate your handling choice lor the plans originally submitted and return this letter to the Building Department Project Abandoned - I will pick up plans within 10 days Project Abandoned - Plans may be destroyed If you have any questions, please contact the Building Department at (760) 602-2718 Raenette Abbey Building Department EsGil Corporation In Partners/iip with, government for 'BuiCding Safety DATE 04/01/02 Q JURISDICTION Carlsbad d PLAN REVIEWER a FILE PLAN CHECK NO . 02-642 SET II PROJECT ADDRESS 2735 Cazadero Dr. PROJECT NAME Miholch Residence Addition and Remodel The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes X] The plans transmitted herewith will substantially comply with the jurisdiction's budding codes when minor deficiencies identified below are resolved and checked by building department staff The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck The check list transmitted herewith is for your information The plans are being held at Esgil Corporation until corrected plans are submitted for recheck The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person The applicant's copy of the check list has been sent to X Esgil Corporation staff did not advise the applicant that the plan check has been completed Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted Telephone #. Date contacted (by ) Fax #: Mail Telephone Fax In Person X REMARKS 1) Complete special inspection form with name of inspector for the epoxy anchors By Ray Fuller for Bill Elizarraras Enclosures Esgil Corporation GA MB EJ PC 03/25/02 tmsmadot 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 *• (858)560-1468 + Fax (858) 560-1576 EsGil Corporation In {Partners/tip with government for 'BuiMing Safety DATE March 12, 2002 LUAPPUCANT JURISDICTION Carlsbad o PLAN REVIEWER Q FILE PLAN CHECK NO 02-642 SET I PROJECT ADDRESS 2735 Cazadero Dr. PROJECT NAME Miholch Residence Addition and Remodel The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck XI The check list transmitted herewith is for your information The plans are being held at Esgil Corporation until corrected plans are submitted for recheck The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person [X] The applicant's copy of the check list has been sent to Phil Weatherly 3323 Par Dr Oceanside, CA 92056 Esgil Corporation staff did not advise the applicant that the plan check has been completed XI Esgil Corporation staff did advise the applicant that the plan check has been completed Person contacted Phil Weatherly (V-H) Telephone # 760-433-7842 Date contacted. 3//3/OZ(by K-) Fax # Mail c-Telephone i/ Fax In Person REMARKS By Bill Elizarraras Enclosures Esgil Corporation n GA D MB D EJ D PC 3/4/02 irnsmtldot 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 4- (858)560-1468 *• Fax (858) 560-1576 Carlsbad O2-642 March 12, 2002 PLAN REVIEW CORRECTION LIST SINGLE FAMILY DWELLINGS AND DUPLEXES PLAN CHECK NO O2-642 JURISDICTION Carlsbad PROJECT ADDRESS 2735 Cazadero Dr. FLOOR AREA 612 sqft. Dwelling Add'n STORIES 2 HEIGHT 23'-6" REMARKS DATE PLANS RECEIVED BY JURISDICTION DATE INITIAL PLAN REVIEWCOMPLETED March 12,2002 DATE PLANS RECEIVED BY ESGIL CORPORATION 3/4/02 PLAN REVIEWER Bill Elizarraras FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled This plan review is based on regulations enforced by the Building Department You may have other corrections based on laws and ordinance by the Planning Department, Engineering Department, Fire Department or other departments Clearance from those departments may be required prior to the issuance of a building permit Present California law mandates that residential construction comply with the 1998 edition of the California Building Code (Title 24), which adopts the following model codes 1997 UBC, 1997 UPC, 1997 UMC and 1996 NEC (all effective 7/1/99) The above regulations apply to residential construction, regardless of the code editions adopted by ordinance The following items listed need clarification, modification or change All items must be satisfied before the plans will be in conformance with the cited codes and regulations Per Sec 106 4 3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e.. plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans. Carlsbad 02-642 March 12, 2002 • PLANS 1 Please make all corrections on the original tracings, as requested in the correction list Submit three sets of plans for commercial/industrial projects (two sets of plans for residential projects) For expeditious processing, corrected sets can be submitted in one of two ways 1 Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave , Carlsbad, CA 92008, (760) 602-2700 The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments 2 Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468 Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments NOTE Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete 2 Plans, specifications and calculations shall be signed and sealed by the California State licensed engineer or architect responsible for their preparation, for plans deviating from conventional wood frame construction Specify expiration date of license (California Business and Professions Code) 3 When special inspection is required, the architect or engineer of record shall prepare an inspection program which shall be submitted to the building official for approval prior to issuance of the building permit Please review Section 106.3 5 Please complete the attached form 4 Show adequate footings under all bearing walls and shear walls This applies to Garage wall and stairwell common to existing Dwelling Section 1806 3 5 Show the required ventilation for attics The minimum vent area is 1/150 of attic area (or 1/300 of attic area if at least 50% of the required vent is at least 3 feet above eave vents or cornice vents) Show area required and area provided Section 15053 6 Show, on floor plan, adjacent rooms with window sizes indicated to verify compliance with light and ventilation and egress requirements This applies to upper floor level Carlsbad 02-642 March 12, 2002 7 Note on the plans: "The manufactured windows shall have a label attached certified by the National Fenestration Rating Council (NFRC) and showing compliance with the energy calculations " 8 The regulations require an updated CF-1R and MMR forms to match submitted documents to be either imprinted on the plans, taped to the plans or "sticky backed" on the plans, to allow the building inspector to readily compare the actual construction with the requirements of the approved energy design • MISCELLANEOUS To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i e , plan sheet, note or detail number, calculation page, etc The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123, telephone number of 858/560-1468, to perform the plan review for your project If you have any questions regarding these plan review items, please contact Bill Elizarraras at Esgil Corporation Thank you Carlsbad 02-642 March 12, 2002 City of Carlsbad Building Department BUILDING DEPARTMENT NOTICE OF REQUIREMENT FOR SPECIAL INSPECTION Do Not Remove From Plans Plan Check No 02-642 Job Address or Legal Description 2735 Cazadero Dr. Owner Address You are hereby notified that in addition to the inspection of construction provided by the Building Department, an approved Registered Special Inspector is required to provide continuous inspection during the performance of the phases of construction indicated on the reverse side of this sheet The Registered Special Inspector shall be approved by the City of Carlsbad Building Department prior to the issuance of the building permit Special Inspectois having a current certification from the City of San Diego, Los Angeles, or ICBO are approved as Special Inspectors for the type of construction for which they are certified The inspections by a Special Inspector do not change the requirements for inspections by personnel of the City of Carlsbad building department The inspections by a Special Inspector are in addition to the inspections normally required by the County Building Code The Special Inspector is not authorized to inspect and approve any work other than that for which he/she is specifically assigned to inspect The Special Inspector is not authorized to accept alternate materials, structural changes, or any requests for plan changes The Special Inspector is required to submit wntten reports to the City of Carlsbad building department of all work that he/she inspected and approved The final inspection approval will not be given until all Special Inspection reports have been received and approved by the City of Carlsbad building department Please submit the names of the inspectors who will perform the special inspections on each of the items indicated on the reverse side of this sheet (over) Carlsbad 02-642 March 12, 2002 SPECIAL INSPECTION PROGRAM ADDRESS OR LEGAL DESCRIPTION: 2735 Cazadero Drive PLAN CHECK NUMBER: 02-642 OWNER'S NAME: Miholch I, as the owner, or agent of the owner (contractors may not employ the special inspector), certify that I, or the architect/engineer of record, will be responsible for employing the special inspector(s) as required by Uniform Building Code (UBC) Section 1701 1 for the construction project located at the site listed above UBC Section 106 3 5 Signed ^ I, as the engineer/architect of record, certify that I have prepared the following special inspection program as required by UBC Section 106 3 5 for the construction project located at the site listed above Engineer sJArchitect s Seal & Signature Han Signed 1. List of work requiring special inspection- O Soils Compliance Prior to Foundation Inspection G Structural Concrete Over 2500 PSI d Prestressed Concrete Q Structural Masonry [H Designer Specified n Field Welding D High Strength Bolting Q Expansion/Epoxy Anchors n Sprayed-On Fireproofing D Other 2 Name(s) of individuaJ(s) or firm(s) responsible for the special inspections listed above: A B. C. 3. Duties of the special inspectors for the work listed above. A. B C. Special inspectors shall check in with the City and present their credentials for approval grjor to beginning work on the job site Carlsbad O2-642 March 12, 2002 JURISDICTION Carlsbad VALUATION AND PLAN CHECK FEE PREPARED BY Bill Elizarraras BUILDING ADDRESS 2735 Cazadero Dr. BUILDING OCCUPANCY R3/U1 PLAN CHECK NO : O2-642 DATE March 12, 2002 TYPE OF CONSTRUCTION VN BUILDING PORTION Dwelling Add'n Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code AREA ( Sq Ft ) 612 cb Valuation Multiplier City Estimate By Ordinance Reg Mod VALUE ($) 63,036 63,036 $398 96 1994 UBC Plan Check Fee Type of Review Repetitive FeeRepeats Complete Review D Other r-i Hourly Structural Only Hour Esgil Plan Review Fee $259.32 $223.42 Comments Sheet 1 of 1 macvalue doc City of Carlsbad DATE Public Works BUILDJNG PLANCHECK CHECKLIST PLANCHECK NO CB ngineering BUiLDING ADDRESS PROJECT DESCRIPTION ASSESSOR'S PARCEL NUMBER ENGINEERING DEPARTMENT APPROVAL The item you have submitted for review has been approved The approval is based on plans, information and/or specifications provided in your submittal, therefore any changes to these items after this date, including field modifications, must be reviewed by this office to insure continued conformance with applicable codes Please review carefully all comrnents attached, as failure to comply with instructions in this report can result in suspension of permit to build D A Right-of-Way permit is required pnor to construction of the following improvements EST VALUE DENIAL Please see^-the attached report of deficiencies marked witr/D Make necessary corrections to plans or specifications for compliance with applicable codes and standards Submit conected plans and/or specifications to this office for review Date By By Date Date ,•1 t •_ >i " Y** %- j i lii. "' Pv, ta--^' •*-•" r* ;•'--*-. ,-• r • c ^ \ * ~,' ' r- V ,'-FOR OFFICIAL-.USE ONLY,'; !" ,j " ^ENGINEERING AUTHORIZATION TO ISSUE BUILDING PERMIT. ' , 7 I / :"'fr' „! Date ATTACHMENTS LI Dedication Application L-1 Dedication Checklist t-J Improvement Application U Improvement Checklist L-l Future Improvement Agreement l-l Grading Permit Application D Grading Submittal Checklist D Right-of-Way Permit Application D Right-of-Way Permit Submittal Checklist and Information Sheet ENGINEERING DEPT CONTACT PERSON Name TANIYA WADE City of Carlsbad Address 1635 Faraday Avenue. Carlsbad. CA 92008 Phone (760) 602-2773 CFD INFORMATION! Parcel Map No Lots Recordation Carlsbad Tract D Sewer Fee Information Sheet A-4 rada: ling 4je • Carlsbad, CA 92008-7314 • (76O) 602-272O • FAX (760) 602-85621FofmJJ(toC 1 12/28/96 BUILDING PLANCHECK CHECKLIST ST >RD SITE PLAN 1 Provide a fully dimensioned site plan drawn to scale Show. A North Arrow B Existing & Proposed Structures C Existing Street Improvements D Property Lines E Easements F Right-of-Way Width & Adjacent Streets G Driveway widths H Existing or proposed sewer lateral I Existing or proposed water service J Existing or proposed irrigation service CH C3 2 Show on site plan. Patterns 1 Building pad surface drainage must maintain a minimum slope of one percent towards an adjoining street or an approved drainage course 2 ADD THE FOLLOWING NOTE "Finish grade will provide a minimum positive drainage of 2% to swale 5' away from building " B Existing & Proposed Slopes and Topography C Size, type, location, alignment of existing or proposed sewer and water service (s) that serves the project Each unit requires a separate service, however, second dwelling units and apartment complexes are an exception D Sewer and water laterals should not be located within proposed driveways, per standards. 3 Include on title sheet A Site address B Assessor's Parcel Number C. Legal Description For commercial/industrial buildings and tenant improvement projects, include total building square footage with the square footage for each different use, existing sewer permits showing square footage of dilferent uses (manufacturing, warehouse, office, etc ) previously approved EXISTING PERMIT NUMBER DESCRIPTION H \WORDUX)£s\CHKLS'nBuUln(j PlanchM* CUM Form (Generic) doc BUILDING PLANCHECK CHECKLIST •i ST 2ND 3rd n D DISCRETIONARY APPROVAL COMPLIANCE 4a Project does not comply with the following Engineering Conditions of approval for Project No HH CD CH 4b All conditions are in compliance Date n DEDICATION REQUIREMENTS 5 Dedication for all street Rights-of-Way adjacent to the building site and any storm dram or utility easements on the building site is required for all new buildings and for remodels with a value at or exceeding $15,000, pursuant to Carlsbad Municipal Code Section 18 40 030 Dedication required as follows Dedication required Please have a registered Civil Engineer or Land Surveyor prepare the appropriate legal description together with an 8 Y*" x 11" plat map and submit with a title report All easement documents must be approved and signed by owner(s) prior to issuance of Building Permit Attached please find an application form and submittal checklist for the dedication process Submit the completed application form with the required checklist items and fees to the Engineering Department in person Applications will not be accept by mail or fax Dedication completed by Date D IMPROVEMENT REQUIREMENTS 6a All needed public improvements upon and adjacent to the building site must be constructed at time of building construction whenever the value of the construction exceeds $75.000. pursuant to Carlsbad Municipal Code Section 1840040 Public improvements required as follows Attached please find an application form and submittal checklist for the public improvement requirements A registered Civil Engineer must prepare the appropriate improvement plans and submit them together with the requirements on the attached checklist to the Engineering Department through a separate plan check process The completed application form and the requirements on the H \WORl>OOCSlCHKLST\BiitWl^l Plandwck CMM Fonti (RIDDLE HARVEY 7 1J-00) Ooc . ST BUILDING PLANCHECK CHECKLIST checklist must be submitted in person Applications by mail or fax are not accepted Improvement plans must be approved, appropriate securities posted and fees paid prior to issuance of building permit. Improvement Plans signed by Date D D D 6b Construction of the public improvements may be deferred pursuant to Carlsbad Municipal Code Section 1840. Please submit a recent property title report or current grant deed on the property and processing fee of $310 so we may prepare the necessary Future Improvement Agreement This agreement must be signed, notarized and approved by the City prior to issuance of a Building permit Future public improvements required as follows C3 D 6c Enclosed please find your Future Improvement Agreement Please return agreement signed and notarized to the Engineering Department Future Improvement Agreement completed by. Date D CD D 6d No Public Improvements required SPECIAL NOTE Damaged or defective improvements found adiacent to building site must be repaired to the satisfaction of the City Inspector prior to occupancy GRADING PERMIT REQUIREMENTS The conditions that invoke the need for a grading permit are found in Section 11 06 030 of the Municipal Code. D D D 7a Inadequate information available on Site Plan to make a determination on grading requirements Include accurate grading quantities (cut, fill import, export) D D D 7b Grading Permit required A separate grading plan prepared by a registered Civil Engineer must be submitted together with the completed application form attached NOTE* The Grading Permit must be issued and rough grading approval obtained prior to issuance of a Building Permit Grading Inspector sign off by: Date- D D D 7c Graded Pad Certification required (Note Pad certification may be required even if a grading permit is not required ) H \WOnCMXJCS\CHKLSTlBuildin9 Planch** CW*t Form (Genorte 7 14-OOJ doc BUILDING PLANCHECK CHECKLIST )RD (n)n n n n n n n 7d No Grading Permit required 7e If grading is not required, write "No Grading" on plot plan MISCELLANEOUS PERMITS 8 A RIGHT-OF-WAY PERMIT is required to do work in City Right-of-Way and/or private work adjacent to the public Right-of-Way Types of work include, but are not limited to street improvements, tree trimming, driveway construction, tying into public storm drain, sewer and water utilities Right-of-Way permit required for ^ INDUSTRIAL WASTE PERMIT If your facility is localed in the City of Carlsbad sewer service area, you need to contact the Carlsbad Municipal Water District, located at 5950 El Cammo Real, Carlsbad, CA 92008 District personnel can provide forms and assistance, and will check to see if your business enterprise is on the EWA Exempt List You may telephone (760) 438-2722, extension 7153, for assistance Industrial Waste permit accepted by Date 10 NPDES PERMIT Complies with the City's requirements of the National Pollutant Discharge Elimination System (NPDES) permit The applicant shall provide best management practices to reduce surface pollutants to an acceptable level prior to discharge to sensitive areas Plans for such improvements shall be approved by the City Engineer prior to issuance of grading or building permit, whichever occurs first 11 Q Required fees are attached GHMO fees required WATER METER REVIEW 12a Domestic (potable) Use Ensure that the meter proposed by the owner/developer is not oversized Oversized meters are inaccurate during low-flow conditions If it is oversized, for the life of the meter, the City will not accurately bill the owner for the water used. • All single family dwelling units received "standard" 1" service with 5/8" service. H \WQRD\DOCS\CHKLST\BuKing PtanOwtit CUst Form (Generic) doc -|ST >ND >RD Q D D 12b BUILDING PLANCHECK CHECKLIST • If owner/developer proposes a size other than the "standard", then owner/developer must provide potable water demand calculations, which include total fixture counts and maximum water demand in gallons per minute (gpm) A typical fixture count and water demand worksheet is attached Once the gpm is provided, check against the "meter sizing schedule" to verify the anticipated meter size for the unit • Maximum service and meter size is a 2" service with a 2" meter • If a developer is proposing a meter greater than 2", suggest the installation of multiple 2" services as needed to provide the anticipated demand (manifolds are considered on case by case basis to limit multiple trenching into the street) Irrigation Use (where recycled water is not available) All irrigation meters must be sized via irrigation calculations (in gpm) prior to approval The developer must provide these calculations Please follow these guidelines 1 If the project is a newer development (newer than 1998), check the recent improvement plans and observe if the new irrigation service is reflected on the improvement sheets If so, at the water meter station, the demand in gpm may be listed there Irrigation services are listed with a circled T, and potable water is typically a circled "W" The irrigation service should look like STA 1+00 Install 2" sen/ice and 5 meter (estimated 100 gpm) If the improvement plans do not list the irrigation meter and the service/meter will be installed via another instrument such as the building plans or grading plans (w/ a right of way permit of course), then the applicant must provide irrigation calculations for estimated worst-case irrigation demand (largest zone with the farthest reach) Typically, Larry Black has already reviewed this if landscape plans have been prepared, but the applicant must provide the calculations to you for your use Once you have received a good example of irrigation calculations, keep a set for your reference In general the calculations will include • Hydraulic grade line • Elevation at point of connection (POC) • Pressure at POC in pounds pei square inch (PSI) • Worse case zone (largest, farthest away from valve • Total Sprinkler heads listed (with gpm use per head) • Include a 10% residual pressure at point of connection In general, all major sloped areas of a subdivision/project are to be irrigated via separate irrigation meters (unless the project is only SFD with no HOA). As long as the project is located within the City recycled water H \wORD\DOCSlCHKLSTVBuMlno Plandwck CUM Form (Generic) doc Rev 7114100 •| ST BUILDING PLANCHECK CHECKLIST pND 3RD service boundary, the City intends on switching services/meters to a new recycled water line in the future D [H 12c Irrigation Use (where recycled water is available) these irrigation 1 Recycled water meters are sized the same as the irrigation meter above 2 If a project fronts a street with recycled water, then they should be connecting to this line to irrigate sfopes within the development For subdivisions, this should have been identified, and implemented on the improvement plans Installing recycled water meters is a benefit for the applicant since they are exempt from paying the San Diego County Water Capacity fees However, if they front a street which the recycled water is there, but is not live (sometimes they are charged with potable water until recycled water is available), then the applicant must pay the San Diego Water Capacity Charge If within three years, the recycled water line is charged with recycled water by CMWD, then the applicant can apply for a refund to the San Diego County Water Authonty (SDCWA) for a refund However, let the applicant know that we cannol guarantee the refund, and they must deal with the SDCWA for this D 13 Additional Comments: Ito* HAWORDCOCaCHKLSTlBifldlng Planctwt* CkW Fwm (Generic) doc O O L> D D PLANNING DEPARTMENT BUILDING PLAN CHECK REVIEW CHECKLIST Plan Check No CB Planner APN Address Phone (760) 602- Type of Project & Use Zoning r\ \ ^/'S General Plan Net Project Density CFD (in/out) #_Date of participation Facilities Management Zone Remaining net dev acres Circle One (For non-residential development Type of land used created by this permit ) Legend Item Complete Environmental Review Required DATE OF COMPLETION Item Incomplete - Needs your action YES NO TYPE Compliance with conditions of approval7 If not, state conditions which require action Conditions of Approval Discretionary Action Required APPROVAL/PESO NO PROJECT NO YES NO TYPE DATE OTHER RELATED CASES Compliance with conditions or approval7 If not, state conditions which require action Conditions of Approval f~l Coastal Zone Assessment/Compliance Project site located in Coastal Zone7 YES_ CA Coastal Commission Authority7 YES NO NO If California Coastal Commission Authority Contact them at - 7575 Metropolitan Drive, Suite 103, San Diego CA 92108-4402, (61 9) 767-2370 Determine status (Coastal Permit Required or Exempt) Coastal Permit Determination Form already completed7 YES If NO, complete Coastal Permit Determination Form now Coastal Permit Determination Log # NO D D Follow-Up Actions 1} Stamp Building Plans as "Exempt" or "Coastal Permit Required" (at minimum Floor Plans) 2) Complete Coastal Permit Determination Log as needed Inclusionary Housing Fee required YES NO (Effective date of Inclusionary Housing Ordinance - May 21, 1993 ) Data Entry Completed7 YES NO (A/P/Ds, Activity Maintenance, enter CB#, toolbar, Screens, Housing Fees, Construct Housing Y/N, Enter Fee, UPDATE') H \ADMIN\COUNTER\BtdgPlnchkRevChklst Rev 9/01 Lj n n v Site Plan 1 Provide a fully dimensional site plan drawn to scale Show North arrow, property lines, easements, existing and proposed structures, streets, existing street improvements, right- of-way width, dimensional setbacks and existing topographical lines (including all side and rear yard slopes) 2 Provide legal description of property and assessor's parcel number Policy 44 - Neighborhood Architectural Design Guidelines 1 Applicability YES NO 2 Project complies YES NO/ Zoning 1 Setbacks Front Interior Side Street Side Rear Top of slope 2 Accessory structure Front Interior Side Street Side^. — Reat^^"^ ^.^-^Structure separation Required Required ff**) ' Required ^ """" Required <?V*) ' Required ^ >~" setbacks ^^^^^ Required " _^-~"~Required Required Required Required Shown j Shown Shown Shown _Q Shown ' Shown Shown Shown Shown Shown 736 7 //S/ ' ' ?; 3 Lot Coverage 4 Height 5 Parking Required _--' Required Spaces Required Shown Shown Shown CH (breakdown by uses for commercial and industrial piojects required) Residential Guest Spaces Required Shown Additional Comments OK TO ISSUE AND ENTERED APPROVAL INTO COMPUTE DATE H \ADMlN\COUNTER\BldgPlnchkRevChklst Rev 9/01 SOUTH COAST STRUCTURAL DESIGN 2415 San Diego, Suite 200 San Diego, CA 92110 (619)291-4224 STRUCTURAL CALCULATIONS PROJECT:Miholich Residence 2735 CazaDero Drive La Costa, CA OWNER: Bill & Candy Miholich 273 5 CazaDero Drive La Costa, CA DESIGNER:Phil Weatherly 3323 Par Drive Oceanside, CA 92056 JOB No. :99173 DATE: December 14, 1999 No. 4352 Exp 3-3£-02 ,n0 4 SHEET NO = OF SOUTH COAST -r 6 STRUCTURAL DESIGN CALCULATED BY ^ DATE CHECKED BY /I*--S. . DATE SCALE TABLE OF CONTENTS SUBJECT SHEET DESIGN CRITERIA -^ LOADS -3 VERTICAL ANALYSIS 4- FOUNDATION DESIGN ^ LATERAL ANALYSIS ^ DETAILS ^ JOB SOUTH COAST STRUCTURAL DESIGN SHEET NO CALCULATED BY CHECKS: av _ SCALE _ OF_ DATE DATE GOVERNING CODE: CONCRETE. MASONRY. MORTAR: GROUT. REINFORCING STEEL. STRUCTURAL STEEL. WELDING. SAWN LUMBER: TJIJOISTS: GLULAMS: MICROLLAMS/ PARALLAMS: SOIL: DESIGN CRITERIA UBC 1997 Fc = 2000 PSI, NO SPECIAL INSPECTION REQ'D, (UNO) ASTM C90, FM = 1500 PSI, NO SPECIAL INSPECTION REQ'D, (UNO) ASTM C270, Fc = 1300 PSI, TYPE S ASTM C476, Fc - 2000 PSI ASTM A6 1 5, Fy = 40 KSI FOR « AND SMALLER ASTM A615, Fy = 60 KSI FOR 44 AND LARGER (UNO) ASTM A36. Fy = 36 KSI (STRUCTURAL SHAPES AND PLATES) ASTM A500, GRADE B, Fy = 46 KSI (STRUCTURAL TUBING) ASTM A33, GRADE B, Fy - 35 KSI (STRUCTURAL PIPE) E70 SERffiS-TYP., E90 SERIES FORA6I5 GRADE 60 REINFORCING BARS DOUG FIR LARCH, ALLOWABLE UNIT STRESSES PER 1997 UBC. Trus Joist MacMillan - ICBO NER-200 (TJI/15DF, TJI/25DF, TJI/35DF, & TJI/55DF) DOUGLAS FIR OR DOUGLAS FIR/HEM GRADE 24F-V4 (SIMPLE SPANS) GRADE 24F-V3 (CANTILEVERS) Trus Joist MacMillan - ICBO NER-126 (Microilams) UN O Trus Joist MacMillan - ICBO NER-292 CParallams) U.N.O. Q-EXISTING NATURAL SOIL VALUES PER UBC TABLE 18-I-A SOIL CLASSIFICATION - Q SOILS REPORT BY. DATED: ALLOWABLE BEARING PRESSUREACTIVE SOIL PRESSURE (CANTILEVER.)ACTIVE SOIL PRESSURE (RESTRAINED) PASSIVE SOIL PRESSURE COEFFICIENT OF FRICTION PSF PCF/FT PCF/FT PCF/FT JOB SOUTH COAST STRUCTURAL DESIGN SHEET NO CALCULATED BY CHECKED BY SCALE OF DATE DATE LOADS ROOF DEAD LOAD ROOFING MATERIAL { ^ SHEATHING RAFTERS/C J (or) TRUSSES INSULATION DRYWALL OTHER (ELEC ,MECH ,MISC ) TOTAL DEAD LOAD LIVE LOAD (PITCH 4 12) TOTAL LOAD C 0 15 40 1 5 25 05 1=90 •£*« .0 PSF PSF PSF PSF FLOOR DEAD LOAD FLOORING (CARPET & PAD) LT WEIGHT CONCRETE SHEATHING JOISTS .. DRYWALL .. OTHER (ELEC ,MECH ,MISC ) TOTAL DEAD LOAD LIVE LOAD OJSE TOTAL LOAD- PSF EXTERIOR WALL STUDS DRYWALL INSULATION EXTERIOR FINISH (_: OTHER TOTAL LOAD: 10 2.5 15 too 10 PSF b .0 PSF INTERIOR WALL STUDS DRYWALL OTHER TOTAL LOAD: 10 50 10 PSF PSF SOUTH COAST STRUCTURAL DESIGN VERTICAL LEVEL. Qoo£- MEMBERS. &£vw^ . - =A. <-"$ VMARK. R jl - * SPAN* \ "? FT. ^t=— \in 7 nc 1^ nil.CJLATED BY naTF rMECXED BY naTF crAi c ANALYSIS / DESIGN UNIFORM LOAD Wl= fViX>/O(j, jVi^ = ^03 PLF W'—N W: = Pi = PLF S LBS ^^^' ~'r P: = = LBS ^-~— "~ RL = RR = VMAX = MMAX = IREQ o = USE 4 X M. GRADE OR X GRADE. -/MARK. Fte-l- SPAN= 23 FT. &&<<> LBS c^-~~^~~ \"7^l LBS J1 y' , 1_/ LBS SfcSO FT-LBS 2-\\ IK*^^/ & l1^*- ^e =?H CAMBER CAMBER. UNIFORM LOAD Wi= = PLF ^ Wi= = PLF Pi = P r»( RS- 1 ^ V 4- Pi = RL = RH - VMAX = MMAX = IREQ-D = USE: 6 X It GRADE ^« OR : 6"*-4" X \^ GRADE C ^MARK. P>HM SPAN* \0 FT. Wi= '^Sf^i. j ) W2 = = C^^-i LBS LBS = 3^^L LBS v = M<*1 LBS J^ = ^>* <* X LBS *z s = ^31 Wo FT-LBS = n^t LN4^/ s) ^rc_r CAMBER: ^^ ^£ -t •** CAMBER: UNIFORM LOAD ^ ?•= \ 4 4 PLF PLF Pi = &u(2.H-O = l4^^_ LBS Pz = RL = RR = VMAX = MMAX = LBS . '- 1 1^3^ LBS Zei'H LBS i^ |- ^^i7t3 LBS L 3> SStO FT-LBS IREO-D= = /76 IN4 RL w*- USE: 4 X /2- GRADE: OR : X GRADE: CAMBER: CAMBER: JOS c\c\\~?3 SOUTH COAST STRUCTURAL DESIGN SHEET NO OF CALCULATED BY CHECHES BY SC«LH DATE DATE LEVEL. Fv_ooCi MEMBERS: tt«=CDr-v "> /£*<-****>e XMARK. f>H SPAN= 18 5 FT. W,- £iY,Si*> h//L0 ) J- fy& ^ UNIFORM LOAD ?C °/* 3^^ PLF W3=* = PLF Pi =LBS Pi * = LBS RL =* = 33<r 5 LBS RH=* VMAX = = 5^/ LBS = ^5^? LBS MMAX = = /kk-^13 FT-LBS IRECJ'D = - Jx^*$ IN"1 '-2-^^ ° / USE. 3 ''** ' X / ' 7/fe GRADE OR . X GRADE v/MARK. Fu-*^ SPAN= 3 i FT. ^Si- CAMBER. CAMBER UNIFORM LOAD f P Wi^ (?V,L;CSI.C) = (,C>0 PLF ' \Vi* = PLF Pi * ftfl. ( ^£,-Z ^ Pi *= RL ^ = 34 6 i LBS = 2 y?*! 6s T R^ W,^- Ji_^ U3 l^JO 1 RH ^= = 2b^ts LBS -^ii. _J^- 'tl VMAX =Zfe^G LBS ^'^' MMAX- = ^c?^^ FT-LBS IREQ-D = USE: (a X /i GRADE OR: ?'/i" X M7V GRADE 1 / ^MARK. t]B-\ SPAN= -?4 3 FT. Wi*= (Vz)l35 0 > = i"? INH^/b) *? ^p *** CAMBER: ^^ CAMBER: -^ UNIFORM LOAD >/o ft W? ^= = t>T F iTT i ^- 1 i_,l. Pi ^ (-^ /? )C "V5 0 / [ /2. ) RL - = IBS LBS = /2o7 LBS */> RR = = "?Cfff^,< LBS '^ Jy VMAX = MMAX = IREQ D = USE: J>> X // 7y& " GRADE- OR : X GRADE: _ i-lv.^inc -' *-..~ * * ^ — Li3o ?4j .5 S 6 kj> O FT-LBS c?c,3 JNJ*^"-^ ^ ' iC> r ^t_ CAMBER: 'u *• CAMBER: JOB SOUTH COAST STRUCTURAL DESIGN SHEET NO CALCULATED BY CHECKED BY SCALE OF.L DATE DATE FOUNDATIONS ALLOWABLE BEARING PRESSURE, q = looo PSF fPER DESIGN CRITERIA ) CONTINUOUS PERIMETER & BEARING WALL FOOTINGS: Location: u M g" V 01 ^ |j °° |* ^ ^/ ie' M.J - 4 r_ pfj _ PLF Width Required = W /q x 12 =_EN- USE, /z " WIDE x 16" DEEP WITH «— ^ — TOP & BOTTOM Location. Width Requu-ed = W /q x 12 = PLF IN USE."WLDEx "DEEP WITH TOP & BOTTOM ISOLATED SPREAD FOOTINGS: MARK. F-_l__ P = 144 = LBS SO IN USE. 2J_" SQUARE x._/a_"DEEP WITH 2. # ^- EACH WAY(3" CL£.\R FROM SOIL) MARK F- 2- P =BS 144 =£>! \ SQ IN USE. 3o " SQUARE, x. _[b_" DEEP WITH ^ # 4- EACH WAY(3" CLEAR FROM SOIL) JOB 5M6ET NO SOUTH COAST STRUCTURAL DESIGN CALCULATED 3Y CHECKED BY SCALE 7 OF _ OATE DATE LATERAL AiNALYSIS / DESIGN AREA: Seismic = (2.5 Cal/R) Wt Seismic Zone _.4_ Z = $__ Soil Profile^ _Sn Na= \ O Ca= 4 4 [=10 (Standard Occapancv) R= 4 S W = Total Seismic Dead Load Wind: P = CeCqQsI Exposure < Basic Wind Speed - 70 VtPK Ce = . ~)L , UBC Taole 16-G Cq = / 3 . UBC Taoie 16-H Qs = 12 6 psf Iw = 1 0 (Non-Essential Facility) P = Ce Cq Qs I = IL ROOF WEIGHT Diaohragm =o Extenor Wall Weight = AOO )( Interior Wall Weight = ^ 3 o H > • o 7 2 o Total Weight (Tnbutary to Diapnragm} = \S' FLOOR WEIGHT. Diaphragm =» (~?Qc> ) Extenor Wall Weight =\o Interior Wail Weight-* (\o 7, o .LBS .LBS .L3S LBS LBS LBS LBS Total Weight (Tributary to Diaphragm) = Diaphragm FLOOR WEIGHT. Extenor Wall Weight =, Intenor Wall Weight =* . Total Weight (Tributary to Diaphragm) TOTAL DEAD LOAD, Wt =» (•*<*/,+) LBS LBS LBS LBS LBS BASE SHEAR, V Wt UNIT SHEAR, v - V / Area (Applies to single level structures only)PSF SOUTH COAST STRUCTURAL DESIGN JOB SHFFT NO aam. CALCULATED BY CHECKED BY SCALE OF __ DATE DATE LOAD DISTRIBUTION LEVEL hx ROOF 2- \ FT 2 \0 FT \ FT TOTALS wx H 1 K 2u 2. K K K wxhx ?9£ FT-K 2c-Z FT-K FT-K ^uo FT-K Fx 3,7 K 3 3 K K K A d5 FT2 7oo pr2 FT2 FT3 Vx = (Fx/A) 5^ PSF 4 1 PSF PSF PSF SHEARWALL DESIGN ROOF DIAPHRAGM WIND TRIBUTARY AREA , TA = \ TA = SEISMIC (Vx) N-S 5- ^ PSF 5 =1 PSFE-W FLOOR DIAPHRAGM WIND TRIBUTARY AREA, SEISMIC (Vx) N-S A 1 .PSF E-W 4 1 PSF FLOOR DIAPHRAGM WIND , Vx = [ (P x TA)/A] y / PSF PSF j \f IV, ^ \ = \ «L- > )' "^ L ' / TA= WIND , V^ = {(P x TA)/A] 4 > PSF PSF WIND TRIBUTARY AREA , TA = TA= SEISMIC (Vx) N-S PSF E-W PSF WIND , Vx = [ (P xTA)/A] PSF PSF FT2 (N-S) _FT2 (E-W) FT2(N-S) FT2 (E-W) JT2 (N-S) __FT2 (E-W) GOVERNS GOVERNS _GOVERNS GOVERNS _GOVERNS GOVERNS c\ SHEET NO 1__ OF SOUTH COAST DESIGN CALCULATED BY DATE BY DATE SCALE •s >***2~ Floor Shearwaiis M" i Direction Unit Lateral Load, v = ^ \ psf J Line . . Tnbutary Area (This Level) '1 A * ^ ' Lateral Load (This Level) Lateral Load (Roof Level) Lateral Load ( Level) Total Load (All Levels), F Shearwall Lensth, L = /£• ft Unit Wall Shear, v = F/L = /^ plf X ' ^ = \~> \jji- Shearwall Tvpe CD x ""* Overturnme: L = ft i^ Okav bv Inspection OT Moment = Res Moment = Net Moment = Uplift - Hoidown Anchor Tvpe J Line 2_ Tnbutary Area (This Level) Lateral Load (This Level) Lateral Load (Roof Level) Lateral Load ( Level) Total Load (All Levels), F \ Shearwall Lensth. L = "z-o ft Unit Wall Shear, v^ F/L = J^ olf X f -^ - U1^ f'1^ Shearwall Tvpe ^LJ Overturnine: L = ft c-- Okav bv Inspection OT Moment = Res Moment = Net Moment = Uplift = Hoidown Anchor Tvpe ^^3» sq ft )8<t4 Lbs Lbs Lbs J&4-4 Lbs FtLbs FtLbs FtLbs Lbs 3» ^ sq ft /fe-t ^ Lbs Lbs Lbs /<544 Lbs FtLbs FtLbs FtLbs Lbs JOB SHEET NO ' ^ OF SOUTH COAST STRUCTURAL DESIGN CALCULATEDBY DATE CHECKED BY _„_ DATE SCALE 1 Floor Shearwalls Direction Unit Lateral Load, v = 4> 7 psf 1 ~~}Qfy. 3 * -iTributary Area (This Level) -3--:' ° sq ft Lateral Load (This Level) t 7 '* Lbs Lateral Load (Roof Level) V^f Lbs Lateral Load ( Level) Lbs Total Load (All Levels), F .jiteJ^ Lbs Shearwall Length, L = 5 & Unit Wall Shear, v = F/L = b16 i i*> 647 Shearwall Type \?) Overturning: L = -5 1-5 ft Okay by Inspection OT Moment = (a47Xs i*Q T a ^ ^ . ^<5,93^ FtLbs Res Moment = O, ^ / \/&)fl<**) Net Moment = _ -?f, 4-7^ FtLbs Uplift - ^33 g Lbs Holdown Anchor Type Tnbutarv Area (This Level) ( '" /^-/ Lateral Load (This Level) Lateral Load fRoof Level) Lateral Load ( e / ^T'^ Level) r/T')C2'A)(^-7^~/ = Total Load (All Levels). F Shearwall Length. L = V-l ft Unit Wall Shear, VJE F/L = (9/ plf X '-v<i = ??? ^J jj Shearwall Type ^} Overturning: L = ft ^ Okav bv Inspection OT Moment = Res Moment = Net Moment = Uplift- Holdown Anchor Tvoe -6"t) /7/-5 / S4 4 69O ^^°)~f C FtLbs FtLbs FtLbs Lbs sq ft Lbs Lbs Lbs Lbs NO " OF _ SOUTH COAST STRUCTURAL DESIGN CALCULATED BY DATE RV HATF "7 i/^*• Floor Shearwalls <=- W Direction Unit Lateral Load, v = 4 °\ osf - Line A- Tnbutary Area (This Level) Lateral Load (This Level) Lateral Load (Roof Level) Lateral Load ( Level) Total Load (All Levels), F Shearwall Lene£h, L = L & ft ^ £_i3D^Js * Unit Wall Shear, v = F/L = 6 1 1 plf O- A ^ - fe Shearwall Type \5) ,o - ? - 2. Overturning: L = £ ^ ft Okay by Inspection OT Moment- (& ' 6 ) (£ ^ *)Ce) = Res Moment = O °\ L (/&)(! (*•<?) +{r*.}( iu «?VJf ^^) /A = Net Moment = Uplift - Holdown Anchor Type V0>*? A ^Line & Tnbutary Area (Thas Level) Lateral Load (This Level) Lateral Load (Roof Level) Lateral Load ( Level) Total Load (AH Levels), F Shearwall Length. L = 2-2> ft Unit Wall Shear. v = F/L = /54 plf Shearwall Type \iy Overturning: L = ft t— Okay by Inspection OT Moment = Res Moment - Net Moment = Uplift = Holdown Anchor Type -£-l£3 sq ft '7' " Lbs '3*ti Lbs Lbs 3551 Lbs •J2- — — - O *5 7 ^* /oO ^*"^l' ^^,6^2. Ft Lbs 6 2^-6 Ft Lbs -5t? , 6.^6 Ft Lbs ^/66 Lbs -5^0 sq ft /?/ 5 Lbs /^•ff- Lbs Lbs ^3^7 Lbs Ft Lbs Ft Lbs Ft Lbs Lbs -ca 5H6E~ NO \ '— OF _1 SOUTH COAST STRUCTURAL DESIGN CALCULATED SATE C-IECXED BY DETAILS SOUTH COAST STRUCTURAL DESIGN JOB SHEET NO CALCULATED BY CHECKED BY _ OF DATE DATE pc u -j I a: 02 Ed 00 00 O PS - GO so X 8 XS BQ ^ t^ • Z £ -» ba 3 S" •? < B•*_•*,-— CO S c» *^ T A •* r- «= B a JOB SOUTH COAST ^^^ — QF STRUCTURAL DESIGN 8Y HOLDOWN SCHEDULE A 4x Post W/ MST37 FLR-To-FLR Holdown B 4x Post W/MST48 FLR-To-FLR Holdown 4x Post W/ MST60 FLR-To-FLR Holdown D 4x Post W/ HPAHD22 Holdown E 4x Post W/ HD2A (SSTB 16) 4x Post W/ HD5A (SSTB 20) G 4x Post W/ HD6A (SSTB 28) H 4x Post W/ HD8A (SSTB 28) I 4x Post W/ HD10A (SSTB 28) J 4x Post W/ HD14A (SSTB 34) .ca 3Hg£- NO -> OF SOUTH COAST STRUCTURAL DESIGN CAISUWTBJ 3v C-ECXED 3V ___ OATH FRAMING NOTES 1 Roof sheathing shall be • 1/2" plywood exposure 1, maex 24/0 • Sd common nails @ 6" o c , B N" • 8d common nails @ 12" o c , F N B N apclies to ail supoorted plywooc edges at* • plvwood eG2es • penmeter walls • shear walls -. Floor sheaifair.g snail be 23;32" A.P A. rated STURD-I-FLOOR, T&G. 24" o c.span rating, exposure 1 • 1/2" plywood exposure I, index 24/0 • lOd common nails @ 6" o c., B N • IQd common nails @ 10" o c, F N B N" applies 10 all supported plywood edges ar • piywood edges • perimeter walls • shear walls TABLE OF CONTENTS TOC Project Title As Designed Date..02/28/02 14 03:39 Project Address . .. 2753 Cazadero ******* San Diego *v6 01* Building Permit # Plan Check / Date Field Check/ Date Documentation Author.. Phil Weatherly ******* Phil D. Weatherly 3323 Par Drive Oceanside, CA 92056 760-433-7842 Climate Zone 07 Compliance Method .. . MICROPAS6 v6.01 for 2001 Standards by Enercomp, Inc. MICROPAS6 v6.01 File-MIHOLICH Wth-CTZ07S92 Program-TOC User#-MP0359 User-Phil D Weatherly Run-Typical House TABLE OF CONTENTS Report Page FORM CF-1R 1 FORM MF-1R 4 FORM C-2R. . . 7 HVAC SIZING .. 10 City of Carlsbad Plumbing - Electrical - Mechanical Worksheet Project Address Permit No. Questions below refer to work being done for this permit only Plumbme * Number of new or relocated fixtures, traps, or floor drains? New building sewer line? Yes _ No Number of roof drains? * Install/alter water line? Yes _ No * Number of water heaters? _ * Number of hose bibs? __ _ * Gas piping system - Install __ Repair _ * Number of new or relocated gas outlets __ * New water meter- No of __ Size Potable _ Irngation _ _ Electrical * Number of new panels or subpanels? __ Size of New Service * Single Phase D Size Number of amperes _ * Three Phase D Number of amperes _ * Three Phase - 480 Number of amperes _ * Remodel (relocate existing outlets/switches or add outlets/switches Yes No Mechanical * Number of furnaces, A/C, or heat pumps? * Number of fireplaces? * Number of exhaust fans? * Number of exhaust hoods? * Number of boilers or compressors? Number of HP? New or relocated duct work? Yes No BEFORE THE PERMIT CAN BE FEE'D OUT THIS FORM NEEDS TO BE RETURNED TO THE BUILDING DEPARTMENT - FAX NUMBER (760) 602-8558 City of Carlsbad ^Q ZL ft 6 * Building Department CERTIFICATE OF COMPLIANCE PAYMENT OF SCHOOL FEES OR OTHER MITIGATION This form must be completed by the City, the applicant, and the appropriate school districts and returned to the City prior to issuing a building permit The City will not issue any building permit without a completed school fee form Project Name Building Permit Plan Check Number Project Address A P.M.: Project Applicant (Owner Name) Project Description. Building Type Residential Second Dwelling Unit: Residential Additions Commercial/Industrial City Certification of Applicant Information Number of New Dwelling Units Square Feet of Living Area in New Dwelling Square Feet of Living Area in SOU Net Square Feet New Area ware Feet Floor Area fHOOL DISTRICTS WITHIN Tl Date CITY OF CARLSBAD Carlsbad Unified School District 801 PineAve Carlsbad CA 92009 (729-9291) -SaiTMarcos Unified School District 215MataWay San Marcos, CA 92069 (736-220Q) Encimtas Union School District 101 South Rancho Santa Fe Rd Encuutas, CA 92024 (944-4300) San Dieguito Union High School District 710 Encimtas Blvd Encimtas, CA 92024 (753-6491) Certification of Applicant/Owners. The person executing this declaration ("Owner") certifies under penalty of perjury that (1) the information provided above is correct and true to the best of the Owner's knowledge, and that Ihe Owner will file an amended certification of payment and pay the additional fee if Owner requests an increase in the number of dwelling units or square footage after the building permit is issued or tf the initial determination of units or square footage is found to be incorrect, and that (2) the Owner is the owner/developer of the above descnbed project(s), or that the person executing this declaration is authorized to sign on behalf of the Owner Signature Date 1635 Faraday Avenue • Carlsbad, CA 92OO8-7314 • (76O) 6O2-27OO • FAX (760) 6O2-856O Revised 4/20/00 SCHOOL DISTRICT SCHOOL FEE CERTIFICATION (To be completed by the school distnct(s))*•**********•*********************•*****+***********************************•************************** THIS FORM INDICATES THAT THE SCHOOL DISTRICT REQUIREMENTS FOR THE PROJECT HAVE . BEEN OR WILL BE SATISFIED SCHOOL DISTRICT The undersigned, being duly authorized by the applicable School District, certifies that the developer, builder, or owner has satisfied the obligation for school facilities. This is to certify that the applicant listed on page 1 has paid all amounts or completed other applicable school mitigation determined by the School District. The City may issue building permits for this project SIGNATURE OF AUTHORIZED SCHOOL DISTRICT OFFICIAL TITLE NAME OF SCHOOL DISTRICT DATE PHONE NUMBER Carlsbad 02-642 March 12, 2002 City of Carlsbad ^ WMM^M^VMBHIMMHl^^^^^^^^^^^^^^^^^^Building Department BUILDING DEPARTMENT NOTICE OF REQUIREMENT FOR SPECIAL INSPECTION Do Not Remove From Plans Plan Check No O2-642 Job Address or Legal Descnption 2735 Cazadero Dr. Owner Address You are hereby notified that in addition to the inspection of construction provided by the Building Department, an approved Registered Special Inspector is required to provide continuous inspection during the performance of the phases of construction indicated on the reverse side of this sheet The Registered Special Inspector shall be approved by the City of Carlsbad Building Department prior to the issuance of the building permit Special Inspectors having a current certification from the City of San Diego, Los Angeles, or ICBO are approved as Special Inspectors for the type of construction for which they are certified The inspections by a Special Inspector do not change the requirements for inspections by personnel of the City of Carlsbad building department The inspections by a Special Inspector are in addition to the inspections normally required by the County Building Code The Special Inspector is not authorized to inspect and approve any work other than that for which he/she is specifically assigned to inspect The Special Inspector is not authorized to accept alternate materials, structural changes, or any requests for plan changes The Special Inspector is required to submit written reports to the City of Carlsbad building department of all work that he/she inspected and approved The final inspection approval will not be given until all Special Inspection reports have been received and approved by the City of Carlsbad building department Please submit the names of the inspectors who will perform the special inspections on-each of the items indicated on the reverse side of this sheet (over) Carlsbad 02-642 March 12, 2002 SPECIAL INSPECTION PROGRAM ADDRESS OR LEGAL DESCRIPTION. 2735 Cazadero Drive PLAN CHECK NUMBER: 02-642 OWNER'S NAME: Miholch I, as the owner, or agent of the owner (contractors may not employ the special inspector), certify that I, or the architect/engineer of record, will be responsible for employing the special mspector(s) as required by Uniform Building Code (UBC) Section 1701 1 for the construction project located at the site listed above UBC Section 106 3 5 Signed I, as the engineer/architect of record, certify that I have prepared the following special inspection program as required by UBC Section 106 3 5 for the construction project located at the site listed above f tlArchitect I Sill ii* Hart Signed 1. List of work requiring special inspection C] Soils Compliance Prior to Foundation Inspection D Structural Concrete Over 2500 PSl Q Prestressed Concrete O Structural Masonry C] Designer Specified Q Field Welding D High Stiength Bolting Q Expansnon/Epoxy Anchors [U Sprayed-On Fireproofing Other 2. Name(s) of individual(s) or firm(s) responsible for the special inspections listed above: A B. C. 3. Duties of the special inspectors for the work listed above: A. B C. Special inspectors shall check in with the City and present their credentials for approval pjigMo beginning work on the job site