Loading...
HomeMy WebLinkAbout2736 LOKER AVE W; C; CB053582; PermitCity of Carlsbad, 1635 FaradayAv Carlsbad, CA 92008 01-04-2006 Commercial/Industrial Permit Permit No: CB053582 Building Inspection Request Line (760) 602-2725 Job Address: 2736 LOKER AV WEST CBAD St: C . Permit Type: TI Sub Type: COMM Parcel No: 0000000000 Lot #: 0 Status: ISSUED Valuation: $46900.00 Construction Type: NEW Applied: 10/17/2005 Occupancy Group: Reference #: Entered By: . SB Project Title: HISAMITSU 1342 SF TI WAREHOUSE: Plan Approved: 01/04/2006 TO CNDITIONED WAREHOUSE Issued: 01/04/2006 Inspect Area: • Plan Check#: Applicant: . Owner: KIMBERLY.KRENCK SUITE 218 RD 92121 .5230 CARROLL CANYON 858-558-5935 7 .7 1 Building Permit , . . ' $337.51 Meter Size Add't Building Permit Fee' / $0.00..;, AddI Red. Water Con. Fee ',. - \ \ $0.00 Plan Check / ,- \. .' $219.38'; . Meter Fee. ' \ $0.00 Add'l Plan Check Fee/ L. ! s0.00 'I' SDCWA Fee \ '' L, $0.00 Plan Check Discount/ / . $0.00 CFD Payoff Fee '- - $0.00 Strong Motion Fee ,' ...- .., $985---- PFF(3105540). ..-'Y , ç,' ) $0.00 Park Fee ''- ., . $0.00 - - PFF (4305540) ,.,,/ $0.00' LFM Fee - .• "$0.00 '. -.License Tax (3104193) '-' -. - . $0.00 Bridge Fee - $0.00 License Tax (4304193) ----i $0.00 BTD#2 Fee . .1 $0.00 Traffic Impact Fee (3105541), '.. .,, ) $0.00 BTD #3 Fee '•. • 2 ç $0.00 ..-Traffic Impact Fee (4305541) '--- -" I $0.00 Renewal Fee .,. $000 PLUMBING TOTALI, "-'- $0.00 Add'I Renewal Fee . - I t$0.00 ELECTRICALTOTAL \"J " / $82.50 Other Building Fee " ' $0.00 ', MECHANICAL.TOTALJ/ / $42.00 Pot. Water Con. Fee \ $0.00-' Mister Drainage Fée i $0.00 Meter Size , --- ? \\, .Sewer Fee + - / I $0.00 AddI Pot. Water Con. Fee "., /so.00 Redev Parking Fee / $0.00 Red. Water Con. Fee \ ' $0.00 Additional Fees / / $0.00 / - I TOTAL PERMIT FEES \ -.."-- / $691.24 Total Fees: $691.24 Total Payments To Date: --.. $691.24' -Balance Due: $0.00 BU1J1NGPLA -IN-SFORA€-E fr-' ___ATTACHED . .'- S LIL_FINAL APPROVA Inspecto.Date: 1-06 . Clearance: NOTICE: Please take NOTICE that approval of your project includes the 'Imposition' of fees, dedications, reservations, or other exactions hereafter collectively referred to as 'fees/exactions.' You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any T52900 1'-:2:`0050 10 117/2005 001 11 tC E$ME L& . -- PERMIT APPLICATION PLAN CHECK NO EST)/AL CITY OF CARLSBAD BUILDING DEPARTMENT. Plan Ck Deposit 3 1635 Faraday Aye, Carlsbad, CA 92008 — Vandated By_________________________ -: Date. EU PRE9.TNFQRM ff 0N — .. Address (include Bldg/Suite #).,, . . .. . ,,. . Business Name (at this address).....................- -I ' ...... Legal Description . . Lot No. Subdivision Name/Numbe......................Unit No. Phase No.. ' Total.# of units q00 Assessor's :'. • :' ' - Assessor's Parcel ,# . Exising Use .' . . . Propose Use-i : '4-oii L' * '.. . ' '.'.:. ': ":.. .. ..: . .• Description of Work SO FT #of. Stories # of Bedrooms " # of Bathrooms Z. '. . . . -. •,. Pp : "s . . . J11114 - w L' 73o -,lI IyQ RJ zlb bko O A (3585s1-SS .ciii 1; Name. f S . . . Address - .. . . City. '-'- State/Zip . Telephone # Fax # . -.— —*-*,- — . —5-- NT' Agm oJtor Or Eg9ë — *-*--- 43II . .... . Name bi 0yy"C€5,I nc. Addrs Citv~ 1TL State/Zip c1'2 Telephone '# WNE j PERTY/OR .. . T. -" -'.-•' Name . Address . City ,. ' State2Z,p . , Tclphone # — — — (Sed. 7p31.5 Business and Professions Code:. Any, City or Cou1.nty which requires a permit,to construct, alter, improve, demolish or repairay structure, prior.to its. t issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law; (Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code) or that he is exempt therefrom, and the basis for the alleged exemption Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($5001) Name . . Address 5t , r'rervro V4 1City 4.n.e State/Zip (.4 'Telephone '- State License .# . •'-' - ' Liceise Class'B1'CO C2.O City BusinessLicense Designer Name I4,iek. Address S2'o City. State/Zip,4 Telephone(8) Stat License #' , • . . .,...' ... . ,.' .. . .. •. L63 KESCOMSAT ION Workers' Compensation Declaration: I hereby affirm under penalty of perjury one of the following declarations: 0 1 have and ,will maintain.a certificate of consent to self-insure for workers' compensation as provided.by, Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. ,. . S •' - ' I. have -and will maintain workers' compensation, as required by Secticn -3700 of the Labor Code, for the 'performance of the work for which this permit is - issued. My worker's compensation insurance carrier and policy number are: • Insurance Compan RLtACOCt Rye- O% Policy No 1J413 9O'1 (,g Expiration Date _7/"j -'O(e (THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS ($1001 OR LESS) ' . --'' •-- :- - - ' • 0 CERTIFICATE OF EXEMPTION: I certify that in the performance of-the work for which this permit is issued, I shall not employ any person in'ny manner soas'i - ' to be'èome subject to the Workers' Compensation Laws of California. ' . , . .' -.5.-- • -, . - ' -: - 'WARNING: Failure to secure-workers' compensa n coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars ($100 00 ), in addition to t,e C $ of compensation, damages as provided for in Section 3706 of the Labo cod ,interest and attorney's fees, SIGNATURE DATE /0 I hereby affirm that lam exempt from the Contractor's License Law for the following reason: •,.- V ,- - ,, ' - . 0 'I, as owner of the proerty or my employees with wages as their sole compensation, will do' the work and the structure is not intended or offered for sale (Sec. ,7044, Business and Professions Code: The Contractor's License' Law does not apply to an. owner of property who builds or.imroves thereon, -and who does., such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however,. the, building or improvement is sold within one year of completion, the owner-builder-will have the burden of proving that he did not build or improve for the purpose of sale). - 0, I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, 'Busiri'ess :and Professions-' C&le: The - - ,' • Contractor's License' La'w does' not'apply to an, owner of prdperty'who builds'or improves thereon,,'and contracts for ,such projects with contractor(s) licensed-., - - pursuant to the Contractor's License Law)1. - 0 . I am exempt under Section Business and Professions Code for this'reason: - - ,.-, . ' ' -'---' * , •. ' . . - - 1 •. I personally plan to provide the major labor and materials for construction of the proposed property improvement. 0 YES - DNO - 2 I (have / have not) signed an application for a building permit for the proposed work ).have contracted with the following person (firm) to provide the proposed construction (include name! address / ph one num be /'cntr'ctors license number): - 4•F 'I plañ'fo provide portions of the work, but I have hired the following person to coordinate, supervise arid provide the major work (include name I address / phone number I contractors license number) - 5. I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone number / type of work)' • , PROPERTY OWNER SIGNATURE • ' .' .. . - -. . .' , DATE 1" ' * — -.. ,- t Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention -' program under Sections 25505, 25533 or 25534 of the Presley-Tanner HazardoUs Substance AccountAct? 0 'YES -D NO'- Is the applicant or future building occupant required to obtain a permit from the air pollution control district ortair quality management district? -[:]---YES 0 NO' - Is the facility to be constructed within 1,000,f eat of the outer boundary of a school site? 0 YES - 0 NO, - - ,' ' '-F • , '. IFANY OF THE ANSWERS ARE YES A FINAL CERTIFICATE OF OCCUPANCYMAY NOT BE'ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND, THE AIR POLLUTION CONTROL DISTRICT. I QQNLRUCTIONILENDING AGENCY I hereby affirm that there is a construction lending eq F C for the performance of the work for which this ermir is issued (Sec 30970) Civil Code) LENDE'S NAME' .- - - • 'r LENDER'S ADDRESS -, -•" - - - ' • - - 9 APPLICANT' -"FICATI' Nc - * j'...* Icertify that I have read the application and state that the above information is correct and that the information on5the plans is accurate: i agree to comply with all . -.' City ordinances and State 'laws relating to building cOnstruction. -.1 'hereby authorize representatives of the Cit, of-Carlsbad to enter upon the above mentioned,; '- property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF .CARLSBAD' AGAINST ALL LIABILITIES, " JUDGMENTS COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS,PERMIT.' * 11 OSHA An OSHA permit is required for excavations over 5 0 deep and demolition or construction of structures over 3 stories in height - • EXPIRATIONI.: Every permit issued by.the building' Official under the provisions of this Code shall expire'bylimitation'and becomenull and void if the building or work authorized by such permit is not commenced within 180 days fro e date of such permit or if the building or work authorized by such permit is suspended or abandoned : at any time-after the work is comm r a perioa of 18d ( action 106.4.4 Uniform Building Code). .'-'- ' V - APPLICANT'SSIGNATUR DATE- '/o,/"/%t"_• -. '- WHITE File YELLOW Applicant PINK Finance F S 06 City of Carlsbad Bldg Inspection Request For: 01/31/2006 Permit# CB053582 Inspector Assignment: PD Title: HISAMITSU 1342 SF TI WAREHOUSE Description: TO CNDITIONED WAREHOUSE Type: TI Sub Type: COMM Phone: 8587408493 Job Address: 2736 LOKER AV WEST Suite: C Lot 0 Location:• . . Inspe or' APPLICANT. KIMBERLY KRENCK Owner: Remarks: Total Time: .' Requested By: GARY Entered By: CHRISTINE CD Description Act Comment 19 Final Structural •, ,_ 29 Final Plumbing- 39 Final Electrical 49 Final Mechanical - -. Comments/Notices/Hold. - o- • OOu) Associated PCRs/CVs , Original PC# Inspection History - . .- Date Description Act lnsp comments - 01/10/2006 14 Frame/Steel/BoltingiWelding AP PD WALLS • 01/10/2006 17 Interior Lath/Drywall AP PD 01/10/2006 34 Rough Electric AP PD 01/10/2006 44 Rough/Ducts/Dampers wc- PD - • EsGil Corporation In (Partnership with covernment for (Building Safety DATE: December 21, 2005 ±PP4JCNT JURISDICTION: City of Carlsbad C3 PLAN REVIEWER 0 FILE PLAN CHECK NO.: 05-3582 SET: III PROJECT ADDRESS: 2736 Loker Ave West Suite C PROJECT NAME: Hisamitsu Pharmaceuticals - TI The plans transmitted herewith have been corrected where necessary and substan t i a l l y c o m p l y with the jurisdiction's building codes. LIII The plans transmitted herewith will substantially comply with the jurisdiction's b u i l d i n g c o d e s when minor deficiencies identified below are resolved and checked by building de p a r t m e n t s t a f f . The plans transmitted herewith have significant deficiencies identified on the en c l o s e d c h e c k l i s t and should be corrected and resubmitted for a complete recheck. The checklist transmitted herewith is for your information. The plans are being h e l d a t E s g i l Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the a p p l i c a n t contact person. The applicant's copy of the check list has been sent to: Esgil Corporation staff did not advise the applicant that the plan check has bee n c o m p l e t e d . Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: . Telephone #: Date contacted: (by: ) Fax # Mail Telephone Fax In Person REMARKS: By: Bryan Zuppiger Enclosures: Esgil Corporation 11 GA 1 MB lJ EJ El PC 12/15/05 trnsmtl.dot 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576 - --. EsGil Corporation In (Partnership with government for Bui&(ing Safety DATE: 12/6/05 JURISDICTION: City of Carlsbad PLAN CHECK NO.: 05-3582 SET:!! PROJECT ADDRESS: 2736 Loker Ave West Suite C PROJECT NAME: Hisamitsu Pharmaceuticals - TI El EEL1 CANT 0 PLAN REVIEWER 0 FILE LII The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. II The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. LI The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. - IV N The applicant's copy of the check list has been sent to: Kimberly Krenek 5230 Carroll Canyon Rd Suite 218, San Diego, CA 92121 Esgil Corporation staff did not advise the applicant that the plan check has been completed. Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Kimberly Krenek Telephone #: 858-558-5935 - Date contacted: \9_\(ok (by: (fr) Fax #: 858-558-5945 Mail Telephone Fax On Person liii REMARKS: . . By: Doug Moody Enclosures: Esgil Corporation t flGA El MB EEJ Pc 11/28/05 trnsmtl.dot 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576 City of Carlsbad 05-3582 12/6/05 RECHECK PLAN CORRECTION LIST fJURISDICTION: City of Carlsbad PLAN CHECK NO.: 05-3582 PROJECT ADDRESS: 2736 Loker Ave West Suite C SET: II DATE PLAN RECEIVED BY DATE RECHECK COMPLETED: ESGIL CORPORATION: 11/28/05 12/6/05 REVIEWED BY: FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and disabled access. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department or other departments. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3, 1997 Uniform Building Code, the approval of the plans, does not permit the violation of any state, county or city law. Please make all corrections on the original tracings and submit two new complete sets of prints to: To facilitate rechecking, please identify, next to each item, the sheet of the plans upon which each correction on this sheet has been made and return this sheet with the revised plans. The following items have not been resolved from the previous plan reviews. The original correction number has been given for your reference. In case you did not keep a copy of the prior correction list, we have enclosed those pages containing the outstanding corrections. Please contact me if you have any questions regarding these items. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located on the plans. Have changes been made not resulting from this list? ,. DYes GINo .4__• (' , , City of Carlsbad 05-3582 12/6/05 Please make all corrections on the original tracings, as requested in the correction list. Submit three sets of plans for commercial/industrial projects (two sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. Please have the document author and the principle designer of the LTG-1-C form sign the imprinted document. The plans still do not have the correct lighting forms. See comment 11. Please review and revise the plans to be consistent with the requirements and imprint on the plans the City of Carlsbad Policies and Procedures for Roof Mounted Equipment to the plans. Please revise the mechanical plans to be consistent with Policy #4. 9. Provide complete energy designs for the proposed changes in the building envelope (new conditioned floor area). Provide the completed ENV- forms showing energy compliance. The energy design package submitted is not consistent with the documents imprinted on the plans. Please revise. 11. The completed and signed ENV-1-C, LTG-1-C, and MECH-1-C forms must be imprinted on the plans. See comment 9. The resubmitted plans included changes to the existing wall from the office to the warehouse. Please correct detail I on sheet A5.2 to show the framing from the top of the wall to the roof structure to be 16" on center and not 4' on center to support the new gypsum wall to the roof. To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. City of Carlsbad 05-3582 12/6/05 Have changes been made to the plans not resulting from this correction list? Please indicate: Yes El No U The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Doug Moody at Esgil Corporation. Thank you. EsGil Corporation In cPartnersfiip with Government for (Building Safety DATE: 11/1/05 L3 APPLICANT JURISDICTION: City of Carlsbad 0 PLAN REVIEWER C3 FILE PLAN CHECK NO.: 05-3582 SET: I PROJECT ADDRESS: 2736 Loker Ave West Suite C PROJECT NAME: Hisamitsu Pharmaceuticals - TI LI The plans transmitted herewith have been corrected where necessary and substantia l l y c o m p l y with the jurisdiction's building codes. LII The plans transmitted herewith will substantially comply with the jurisdiction's buil d i n g c o d e s when minor deficiencies identified below are resolved and checked by building de p a r t m e n t s t a f f . LII The plans transmitted herewith have significant deficiencies identified on the en c l o s e d c h e c k l i s t and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held a t E s g i l Corporation until corrected plans are submitted for recheck. LI The applicant's copy of the check list is enclosed for the jurisdiction to forward t o t h e a p p l i c a n t contact person. Z The applicant's copy of the check list has been sent to: Kimberly Krenek 5230 Carroll Canyon Rd Suite 218, San Diego, CA 92121 LII Esgil Corporation staff did not advise the applicant that the plan check has been completed.' Esgil Corporation staff did advise the applicant that the plan check has been complete d , . Person contacted: Kimberly Krenek Telephone #: 858-558-5935 Date contacted: kk I I c (by: 4 Fax #: 858-558-5945 Mail Telephone J' Fax In Person . LI REMARKS: By: Doug Moody •. - Enclosures: Esgil Corporation fl GA El MB L1 EJ n PC 10/20/05 trnsmtl.dot 9320 Chesapeake Drive. Suite 208 • San Diego, California 92123 • • (858) 560-1468 • Fax(858)560-1576 City of Carlsbad 05-3582 11/1/05 PLAN REVIEW CORRECTION LIST TENANT IMPROVEMENTS IPLAN CHECK NO.: 05-3582 JURISDICTION: City of Carlsbad OCCUPANCY: B/Si USE: Office /Warehouse TYPE OF CONSTRUCTION: Unknown ACTUAL AREA: 1342sf ALLOWABLE FLOOR AREA: STORIES: 1 HEIGHT: 1SPRINKLERS?: Unknown I REMARKS: DATE PLANS RECEIVED BY JURISDICTION: 10/17/05 DATE INITIAL PLAN REVIEW COMPLETED: 11/1/05 OCCUPANT LOAD: 2 DATE PLANS RECEIVED BY ESGIL CORPORATION: 10/20/05 PLAN REVIEWER: Doug Moody FOREWORD (PLEASE READ): This plan review is limited to the technical requirements c o n t a i n e d i n t h e U n i f o r m B u i l d i n g C o d e , Uniform Plumbing Code, Uniform Mechanical Code, N a t i o n a l E l e c t r i c a l C o d e a n d s t a t e l a w s regulating energy conservation, noise attenuation and ac c e s s f o r t h e d i s a b l e d . T h i s p l a n r e v i e w is based on regulations enforced by the Building Depar t m e n t . Y o u m a y h a v e o t h e r c o r r e c t i o n s based on laws and ordinances enforced by the Planni n g D e p a r t m e n t , E n g i n e e r i n g D e p a r t m e n t , Fire Department or other departments. Clearance fro m t h o s e d e p a r t m e n t s m a y b e r e q u i r e d prior to the issuance of a building permit. Code sections cited are based on the 1997 UBC. The following items listed need clarification, modificatio n o r c h a n g e . A l l i t e m s m u s t - b e s a t i s f i e d before the plans will be in conformance with the cited c o d e s a n d r e g u l a t i o n s . P e r S e c . 1 0 6 . 4 . 3 , 1997 Uniform Building Code, the approval of the pl a n s d o e s n o t p e r m i t t h e v i o l a t i o n o f a n y state, county or city law. To speed up the recheck process, please note o n t h i s l i s t ( o r a c o p y ) w h e r e e a c h correction item has been addressed, i.e., plan shee t n u m b e r , s p e c i f i c a t i o n s e c t i o n , e t c . Be sure to enclose the marked up list when you subm i t t h e r e v i s e d p l a n s . TENANT IMPROVEMENTS WITHOUT SPECIFIC ENERGY D A T A O R P O L I C Y S U P P L E M E N T S ( 1 9 9 7 U B C ) tiforw.dot City of Carlsbad 05-3582 11/1/05 Please make all corrections on the original tracings, as requested in the c o r r e c t i o n list. Submit three sets of plans for commercial/industrial projects (two s e t s o f p l a n s for residential projects). For expeditious processing, corrected sets c a n b e submitted in one of two ways: Deliver all corrected sets of plans and calculations/reports directly to the C i t y o f Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008 , ( 7 6 0 ) 602-2700. The City will route the plans to EsGil Corporation and the Ca r l s b a d Planning, Engineering and Fire Departments. Bring one corrected set of plans and calculations/reports to EsGil Corpor a t i o n , 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-146 8 . Deliver all remaining sets of plans and calculations/reports directly to the C i t y o f Carlsbad Building Department for routing to their Planning, Engineering a n d F i r e Departments. . NOTE: Plans that are submitted directly to EsGil Corporation only wil l n o t b e reviewed by the City Planning, Engineering and Fire Departments u n t i l r e v i e w b y EsGil Corporation is complete. .. Each sheet of the plans must be signed by the person responsible fo r t h e i r preparation, even though there are no structural changes. Business a n d Professions Code. 2. Provide a statement on the Title Sheet of the plans stating that this proje c t s h a l l comply with the 2001 edition of the California Building Code (Title 24), w h i c h adopts the 1997 UBC, 2000 UMC, 2000 UPC and the 2002 NEC. A complete description of the activities and processes that will occur in t h i s tenant space should be provided. A listing of all hazardous materials s h o u l d b e included. The materials listing should be stated in a form that would m a k e classification in Tables 3-D and 3-E possible. The building official m a y r e q u i r e a technical report to identify and develop methods of protection from haza r d o u s materials. Section 307.1.6. Please indicate if warehouse racking will be installed as part of this pe r m i t ? I f s o please provide complete plans and calculations. Please note on the plans "AC Cable is not allowed in A, B, E, H, and I occupancies. NM cable is restricted (without City approval) to one and tw o family dwellings. Note on plans that an equipment ground conducto r i s t o b e installed in all flexible conduits". Please have the document author and the principle designer of the LT G - 1 - C form sign the imprinted document. Please review and revise the plans to be consistent with the requirem e n t s a n d imprint on the plans the City of Carlsbad Policies and Procedures for R o o f Mounted Equipment to the plans. 4. City of Carlsbad 05-3582 11/1/05 Please indicate the location of the ladder access to roof mounted HVAC equipment. Provide complete energy designs for the proposed changes in the building envelope (new conditioned floor area). Provide the completed ENV- forms showing energy compliance. On the plans clearly show the wall and roof insulation locations, thickness, and R-values, as per the energy design. . The completed and signed ENV-1-C, LTG-1-C, and MECH-1-C forms must be imprinted on the plans. To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. V Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please indicate: Yes L3 No U The jurisdiction has contracted with Esgil Corporation located at 9320 - Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of V 858/560-1468, to perform the plan review for your project. If you have any V questions regarding these plan review items, please contact Doug Moody at Esgil Corporation Thank you 1 CITY OF CARLSBAD POLICIES AND PROCEDURE NUMBER: 80-6 SUBJECT: ROOF MOUNTED EQUIPMENT EFFECTIVE: 5 /1/92 SECTION: BUILDING DEPARTMENT SUPERSEDES: 80-6(9/10/80) 80-6(5/01/81) PURPOSE: PROVIDE INSTALLATION STANDARDS FOR ALL ROOF MOUNTED EQUIPMENT AND PENETRATIONS ON COMMERCIAL AND INDUSTRIAL BUILDINGS. INTENT: A. Maintain roof integrity. Prevent hazardous condition to firemen who must fight fire on the roof. Provide an installation that is aesthetically sensitive to the building and the adjoining properties. POLICY: 1. All equipment shall be concealed from view and the design shall meet the approval of the Planning Department. 2. All equipment shall be• specifically designed and approved for exterior use and shall be approved by the City of Carlsbad Building Department. .3. All roof mounted equipment shall be on a platform which shall be an integral part of the roof--flashed and waterproofed. When a screen is approved, it shall have as few roof connections as possible and be structurally adequate. . All electrical, plumbing, mechanical duct work and related piping shall be inside the building and not on the roof. All connections related to equipment shall be made in the same roof opening on the platform or have the prior approval from the building official. Sewer vents shall be brought to one main vent below the roof and have one penetration where restrooms or other plumbing fixtures are back to back or in the general proximity. Air exhaust fans and other equipment shall be within the building and use the same roof opening where restrooms and other equipment are back to back or in general proximity. Existing buildings and equipment, remodel or replacement, shall meet the above regulations or shall have the prior approval from the building official. Where new equipment is installed, unused or abandoned equipment, including all roof mounted piping, electrical, mechanical, duct, andother related appurtenances shall be removed from roof and unused openings properly sealed to maintain roof integrity. 'The architect should, through design, conceal the heating/AC unit and other equipment wheth e r they are on the roof or elsewhere. dated By: Approved B City of Carlsbad 05-3582 11/1/05 VALUATION AND PLAN CHECK FEE JURISDICTION: City of Carlsbad PLAN CHECK NO.: 05-3582 PREPARED BY: Doug Moody DATE: 11/1/05 BUILDING ADDRESS: 2736 Loker Ave West Suite C BUILDING OCCUPANCY: B/Si TYPE OF CONSTRUCTION: Unknown BUILDING PORTION AREA (Sq. Ft.) Valuation Multiplier Reg. Mod. VALUE ($) TI 1342 City Valuation 46,970 Air Conditioning Fire Sprinklers TOTAL VALUE 46,970 Jurisdiction Code cb By Ordinance - Bldg. Permit Fee by Ordinance - - - - I $337.51 Plan Check Fee by Ordinance $219.381 Type of Review: . Complete Review fl Structural Only - fl Repetitive Fee El Other Repeats Hourly Hour * • -, Esgil Plan Review Fee - - - $1 89.011 Comments: - Sheet of 1 macvalue.doc PLANNING/ENGINEERING APPROVALS PERMIT NUMBER CB - 3S DATE / LOi ADDRESS 3 RESIDENTIAL TENANTIMPROVEMENT RESIDENTIAL ADDITION MINOR PLAZA CAMINO REAL (<$10,000.00) / CARLSBAD COMPANY STORES VILLAGE FAIRE COMPLETE OFFICE BUILDING OTHER PLANNER DATE E NG IN EG DATE__________________ Docs/Misforms/Planning Engineering Approvals - - l PLANNING DEPARTMENT BUILDING PLAN CHECK REVIEW CHECKLIST Plan Check No. CB Q,15 5 8Z Address73(o Lok Aye- Lusl Planner Chris Sexton Phone (760) 602-4624 APN:g —Ii Type of Pect & Use:__E Net Project Density:DU/AC 31 IV Zoning:P-L General Plan: PT Facilities Management Zone: CFD (In/out) #Date of participation: Remaining net dev acres: ®rit z I ______ (For non-residential development: Type of land used created by th C e n permit: -J Legend: Item Complete 0 Item Incomplete - Needs your action D 0 Environmental Review Required: YES -NO V' TYPE DATE OF COMPLETION:________________ Compliance with conditions of approval? If not, state conditions which require action. Conditions of Approval: Q Discretionary Action Required: YES___ NO V TYPE________ APPROVALJRESO. NO. DATE_____ PROJECT NO. OTHER RELATED CASES: Compliance with conditions or approval? If not, state conditions which require action. Conditions of Approval:________________________________________________________ 0 Coastal Zone Ass.ssment/Compllanc. Project site located in Coastal Zone? YES____ NO____ CA Coastal Commission Authority? YES___ NO___ If California Coastal Commission Authorlty Contact them at - 7575 Metropolitan Drive, Suite 103, San Diego CA 92108-4402; (819) 767-2370 Determine status (Coastal Permit Required or Exempt): Coastal Permit Determination Form already completed?. YES____ NO____ If NO, complete Coastal Permit Determination Form now. Coastal Permit Determination Log #: . Follow-Up Actions: Stamp Building Plans as "Exempt or "Coastal Permit Required" (at minimum Floor Plans). Complete Coastal Permit Determination Log as needed. Q/fJ 0 Inclusionary Housing Fee required: YES ____ NO (Effective date of Inciusionary Housing Ordinance - May 21, 1993.) Data Entry Completed? YES___ NO___ (A/P/Ds, Activity Maintenance, enter CB#, toolbar, Screens, Housing Fees, Construct Housing YIN, Enter Fee, UPDATEI) Site Plan: H:\A0MIMC0UNTER0dQPnchkR.vchkIs1 Rev 0001 UI." Front Required Shown interior Side: Required Shown Street Side: Required Shown_____________ Rear Required Shown Top of slope: Required _____Shown Accessory structure setbacks: Front Required Shown Interior Side: Required Shown Street Side: Required Shown Rear Required Shown Structure separation: Required Shown Lot Coverage: Required Shown Height Required Shown____________ Parking: Spaces Required Shown (breakdown by uses for commercial and industrial projects required ) Residential Guest Spaces Required Shown Provide a fully dimensional site plan drawn to scae. oiiuvv.isus easements, existing and proposed structures, streets, existing S t r e e t i m p r o v e m e n t s , r g h t f . width, dimensional setbacks and existing topographical lines (in c l u d i n g a l l s i d e a n d r e a r ' a r c slopes). Provide legal description of property and assessors parcel numb e r . Policy 44— Neighborhood Architectural Design Guidelines 1. Applicability: YES NO _IL_ '2. Project complies YES_NO________ Zoning: 1. Setbacks: OK TO ISSUE AND ENTERED APPROVAL INTO COMPUTER k&/'$ DATE//b/5 HMDMiNCOUNERaldgPtnchkR.vchld$t Rev 9101 Carlsbad Fire Department Plan Review Requirements Category: TI, COMM 1 Date of Report: 10-24-2005 Reviewed by: Name: KIMBERLY KRENCK Address: - SUITE 218 5230 CARROLL CANYON RD SAN DIEGO CA92121 Prrnit#CB053582 - S Job Name: HISAMITSU 1342 SF TI WAREHOUSE Job Address: 2736 LOKER AV WEST CBAD St: C INCOMFLETIL The item you have submitted for review is incomplete. At this time, this office cannot, adequately conduct a review to- determine oomplianoewith the-applicable codes and-lo; standards. Please review -carefully all comments attached. Please resubmit the necessary plans and/or specifications, with changes "clouded",, to this offic for review and approval. Conditions: Cond: C0N0000828 [MET] APPROVED: THIS PROJECT HAS BEEN REVIEWED AND APPROVED FOR THE PURPOSES OF ISSUANCE OF BUILDING PERMIT. THIS APPROVAL IS SUBJECT TO FIELD INSPECTION AND REQUIRED TEST, NOTATIONS HEREON, CONDITIONS IN CORRESPONDENCE AND CONFORMANCE WITH ALL APPLICABLE REGULATIONS. - THIS APPROVAL SHALL NOT BE HELD TO PERMIT OR APPROVE THE VIOLATION OF ANY LAW. Entry: 10/24/2005 By: GR Action: AP - - JN-03-2006 TUE 11:45 AM C I T Y O F C R S L B D FAX NO. 760 602 8558 F 02 \L\O7 City of San Diego Hazardous Materials Development Services Information and AppIicatkn Serv i c e s cv.. -'03 Questionnaire 1222 First Ave., MS-301 San Diego, CA 92101 31 Appointments (619)446-5300, inf o r m a t i o n ( 6 1 9 ) 4 4 6 - 5 0 0 0 iT _-a--1 - .'z:M\7 - Business Name Nae I Contact Parson Telephone Thsemitsu California Laboratories I (Dange Veerapaneni, Ph.D. I 760-431-4679 - Mailing Address - CI1Y - State - Zip - Plan Fiie# 2736 Loker Ave. West CarisbLd CA 92009 Project Address CIIY3, - State Zip - - Permit 2736 Loker Ave. West Ca$sbd CA 02009 Will your business use, store or dispense any of theolio w i n g h a z a r d o u s m a t e r i a l s ? i t a n y o f t h e i t e m s I s c i r c l e d ( e x c e p t i t e m 1 5 ) , a S o n D i e g o F i r e Department Hazardous Material s i n f o r m a t i o n S h e a ( f o r m F P S - 5 0 0 ) m u s t b e s u b m i t t e d w i t h y o u r p r o j e c t ( o r r e v i e w t o : D e v e l o p m e n t S e r v i c e s . F i r s Hazardous Materials Plan Revi e w , 1 2 2 2 F i r s t A v e n r . . 4 " f l o o r , S a n D i e g o . C A 9 2 1 0 1 ( 6 1 9 ) 4 4 6 - 5 4 4 0 . Explosives or Blasting agents B. Oxidizers 11. Highly Toxic or Toxic Materi a l s Compressed Gases 7. Pyrophorics 12, Radloactives J3. flammable or Combustible Liqui d s 8. Unstable (Reactive) Materials 13. Corrosives 4, Flammable Solids 0. Watar-Reactivas " 14. Other Health Hazards S. Organic Peroxides 10. Cryogenics,, 15. None of These Items Yes No / is your business type listed on It-Id v' Will your business dispose of Ha 1 Will your business store or hand) than 55 gallons, 500 pounds. 20 0 1 Will your business use an exlst i n g l / Will your business store, use or it / Will your business use or install a 1. 1 Will the intended occupant install Control District Permit Categocie i / (Answer only if the answe r t o q u t feet of the outer boundary of a sC and Community College Districts current California Private Sch o o l Code Section 331907 / Does the building or structure for basics? Briefly describe business activity a n d p r o p o s e d Hlsamitsu is leading company in ( h e f i e l d o f t o p i c a l Or Nori Kuzumaki reverse side of this form? irdous Substances or Medical W a s t e i n a n y a m o u n t ? Hazardous Subatancas In quantiti e s e q u a l t o o r g r e a t e r ubic feel or carcinogens/repro d u c t i v e t o x i n s I n a n y . q v a r r t i t y ? or install an underground storag e t a n k ? ndie Regulated Substances (C a i A R P ) ? azardous Wasirt Tank System ( T i t l e 2 2 , A r t i c i s 1 0 ) ? use any of the equipment listed on t h e L i s t i n g o f A i r P o l l u t i o n verse side of this form? n I is yes) Will the subject faci l i t y b e l o c a t e d w i t h i n 1 , 0 0 0 1 (1< through 12) as listed in th e c u r r e n t D i r e c t o r y o f S c h o o l blished by the San Diego Office o f E d u c a t i o n a n d t h e ectory compiled In accordanc e w i t h p r o v i s i o n s o f E d u c a t i o n this demolition permit is reque s t e d contain any friable as- and anri.frrllommafory products. Hisamltsu is owner or Authorized Agent a tenant improvement to add 10/11/2005 I declare under penalty of perjury that to the bes of my knowledge and belief the res_ponses made herein are true and correci .., - FOR OFFICIAL USE ONLY: F I R E D E P A R r M E T O C C U P A N C Y C L A S S I F I C A T I O N : - - Date: - Exempt 0, No Further -County HMO - - Buill(e it But Not For Occupancy ARCO - Released For Occupancy - — - CounhiNMO - T APCO CL t' E\ INITIALS -- OFS r T. -- This formats (or persons with disabilities. HCL CARLSBAD 2005 Physical Hazard Report Summary Storage Closed System Open System CLASS Lbs. Gallons Cu. Ft. Lbs. Gallons Cu. Ft. Lbs. Gallons Location 2736 WARE HOUSE COMBUSTIBLE LIQUID CLASS II 0.9)0 0.000 0.000 0.000 0.000 0.000 0.000 0.000 COMBUSTIBLE LIQUID CLASS 111-A 0.00 0.000 0.000 0.000 0.000 0.000 ' 0.000 0.000 COMBUSTIBLE LIQUID CLASS Ill-B ' 0.00 0.000 0.000 0.000 0.000 0.000 0.000 0.000 COMBUSTIBLE FIBER 0.00 0.000 0.000 0.000 0.000 0.000 0.000 0.000 LKYUUtNlU, FLAMMABLE UK OXIDIZING U.UUU 0.000 0.000 - 0.000 0.000 0.000 0.000 U.UUU EXPLOSIVES 0.0c0 0.000 0.000 0:000 0.000 0.000 0.000 0.000 - FLAMMABLE SOLID 0.00 0.000 0.000 0.000 0.000 '0.000 0.000 0.000 FLAMMABLE, GAS 0.0t0 0.000 0.000 0.000 0.000 0.000 0.000 0.000 FLAMMABLE LIQUID CLASS I-A o.o 0.000 0.000 . 0.000 0.000 0.000 0.000 0.000 FLAMMABLE LIQUID CLASS I-B 0.00 126.720 0.000 0.000 0.000 0.000 0.000 0.000 ' FLAMMABLE LIQUID CLASS I-C . - 0.00 0.000 0.000 0.000 0.000 0.000 0.000 0.000 ORGANIC PEROXIDE, DETONATABLE 010 0.000 0.000 0.000 0.000 0.000 0.000 0.000 ORGANIC PEROXIDES CLASS I 0.0}0 0.000 0.000 0.000 0.000 0.00b 0.000 0.000 ORGANIC PEROXIDES CLASS II 0.00 6.000 0.000 0.000 0.000 0.000 . 0.000 0.000 ORGANIC PEROXIDES CLASS III 0.00 0.000 0.000 • 0.000 0.000 0.000 0.000 0.000 ORGANIC PEROXIDES CLASS IV o.obo 0.000 0.000 0.000 0.000 0.000 0.000 0.000 ORGANIC PEROXIDES CLASS V 0.00 0.000 0.000 0.000 0.000 0.000 0.000 0.000 OXIDIZER CLASS I - 0.00 0.000. 0.000 0.000 0.000 0.000 0.000 0.000 OXIDIZER CLASS 2 0.00 0.000 0.000 0.000 0.000 0.000 , 0.000 0.000 OXIDIZER CLASS 3 - ' 0.00 0.000 0.000 0.000 0.006 0.000 0.000 0.000 OXIDIZER CLASS 4 0.030 0.000 0.000 0.000 0.000 0.000 0.000 0:000 OXIDIZER - GAS o.4o 0.000 0.000 0.000 0.000 0.000 0.000 0.000 OXIDIZER, GASEOUS OR LIQUIFIED 0.00 0.000 0.000 0.000 0.000 0.000 0.000 0.000 PYROPHORIC UNSTABLE (REACTIVE) CLASS I UNSTABLE (REACTIVE) CLASS 2 UNSTABLE (REACTIVE) CLASS 3 ober 07, 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 Page I of HCL CARLSBAD 2005 Physical Hazard Report Summary Storage Closed System Open System CLASS Lbs. 1 Gallons Cu. Ft. Lbs. Gallons Cu. Ft. Lbs. Gallons • UNSTABLE (REACTIVE) CLASS 4 0.0O 0.000 0.000 0.000 0.000 0.000 0.000 0.000 RADIOACTIVES 0.0O 0.000 0.000 0.000 0.000 0.000 0.000 0.000 WATER REACTIVE CLASS I 0.0,O 0.000 0.000 0.000 0.000 0.000 0.000 0.000 WATER REACTIVE CLASS 2 0.00 0.000 0.000 0.000 0.000 0.000 0.000 0.000 WATER REACTIVE CLASS 3 0.40 0.000 0.000 0.000 0.000 0.000 0.000 0.000 NON HAZARDOUS 0.00 0.000 0.000 0.000 0.000 0.000 0.000 0.000 Friday, October 07, 2005 , Page 2 of 2 HCL CARLSBAD 2005 Health Hazard Report Summary Location CLASS CORROSIVES 2736 WARE HOUSE Storage Lbs. Gallons Ct. 10.000 0.000 - Closed System Open System Ft. Lbs. Gallons Cu. Ft. Lbs. Gallons 0.000 0.000 0.000 0.000 0.000 0.000 HIGHLY TOX ICS 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 IRRITANTS . 132.159 126.720 0.000 0.000 0.000 0.000 0.000 0.000 SENSITIZERS 0.000 -0.000 0.000 0.000 0.000 0.000 0.000 -0.000 OTHER HEALTH HAZARDS 0.000 100.320 0.000 0.000 0.000 0.000 0.000 0.000 TOXICS - 0.000 0.000 0.000 0.000 0.000 - 0.000 0.000 0.000 Inventory Report for' HCL CARLSBAD 200 Location 2 73 6 WAAJE HOUSE Class: FLAMMABLE LIQUID CLJ.ISS Cname CAS# I-B (LIQUIDS) Unit Quantity Quantity in Gallon Ethanol 64-17-5 G 23.760 23.760 Ethyl Acetate . 141-78-6 G 26.400 26.400 Isopropyl Alcohol 67-63-0 G 3.960 3.960 Toluene 108-88-3 0 72.600 72.600 Summary for Gallons (4 detail records) 4 Class: IRRITANTS (LIQUIDS) Cname CAS# Unit Sum Quantity 126.720 Quantity in Gallon Ethanol 64-17-5 G 23.760 23.760 Ethyl Acetate . 141-78-6 G 26.400 26.400 Isopropyl Alcohol 67-63-0 G 3.960 3.960 Toluene 108-88-3 G 72.600 72.600 Summary for Gallons (4 detail records) Class: IRRITANTS (SOLID) Cname CAS# Unit Sum Quantity 126.720 Quantity in Lbs. Polyisobutylene 1,200,000 9003-274 KG 60.000 132.159 Summary for Lbs. (I detail record) Class: OTHER HEALTH HA ZARDS Cname CAS# Sum (LIQUIDS) Unit Quantity 132.159 Quantity in Gallon Ethanol . 64-17-5 G 23.760 23.760 Isopropyl Alcohol 67-63-0 G 3.960 3.960 Friday, October 07, 2005 . Page 1 of 2 Location 2 73 6 WARIE HOUSE Class: OTHER HEALTH HA ZARDS (LIQUIDS) Cname CA S# Unit Quantity Quantity in Gallon Toluene .108-88-3 G 72.600 72.600 Summary for Gallons (3 detail records) Sum 100.320 Page 2 of 2 Friday, October 07, 2005