HomeMy WebLinkAbout2736 LOKER AVE W; F; CB071647; PermitCity of.Carlsbad .-• ,
1635 Faraday Av Carlsbad, CA 92008
07-31-2007 A Comriiercial/IndustriaI Permit Permit No: CB071647
Building Inspection Request Line (760) 602-2725
Job Address: 2736 LOKER AV WEST CBAD St: F
Permit Type: TI Sub Type: INDUST '
Parcel No: 2090812900 Lot #: '.0 'Status: ISSUED
Valuation: $67,235.00 Construction Type: NEW Applied: 06/14/2007
Occupancy Group: V Reference #: 1/ . Entered By: JMA
Project Title: SPEC SUITE:1921 SF SHELL TO Plan Approved: 07/31/2007
OFFICE ' Issued: 07/31/2007
Inspect Area:
V Plan Check#:
Applicant:
DESIGN/BUILD TENANT IMP
SUITE B V
9770 CARROLL CENTER RD
SAN DIEGO, CA 92126
619-954-9519
-
FENTON H G COMPANY
V
7577 MISSION VALLEY RD
Z SAN DIEGOJCA 92108'
/ (\
V I
Building Permit / (\ V'$423,36 Meter Size ''•
- AddI Building Permit Fee // $0.00 AddI Rebl'Water Con. Fèe'"O)
Plan Check / 7 $275.18 .71MeterFee
Add'l Plan Check Fee /l, / $0.00. SDCWA Fee
Plan Check Discount / $0.00. CFD Payoff Fee.
Strong Motion Fee i N ,$14.12 V_ :PFF(3105540) ;3/ \ Park Fee ' $0.00 T, PFF.(4305540) J
$0.00
$0.00
License Tax (3104193)
license Tax (4304193)/1 c
))
V $0.00 ,,Traffic lmiact Fee (3105541)1
$0.00'ç 'Traffic Impact Fee (4305541)
$0.00 1 FLUMBlNGTOTAL\
.i $0.00 ELECTRICAL TOTAL
$0.00, MECHANICAL TOTAL"
$0.00. V' Master Dráihage,Fee
$0.00
Sewer Fee V
Redev Parking Fee
'$0.00 c Adthtion:l Fees
1
HMP Fee
PERMIT FEES\\ .TOTAL \\ J
V I •
VV\
/ \VV,_
LFM Fee
Bridge Fee I
'\ V BTD#2 Fee
BTD#3 Fee
Renewal Fee
Add'l Renewal Fee
Other Building Fee
Pot. Water Con. Fee'.
Meter Size
Add'l Pot. Water Con. Fee
Red. Water Con. Fee
$0.00
$0.00
$0.00
$0.00 V
$1,223.68
$0.00
$0.00
$0.00
$812.00
$0.00
$41.00
$20.00
$21.50
$0.00
$1,234.88
V $0.00.
$0.00
29
$4,065.72
Total Fees: $4,065.72 Total Paymentá T6Date:' , , $4,065.72 Balanée Due: $0.00
-
- - V
BUILDING PLANS
V V
ATTACHED
Inspector
FINAL APPROVAL
Clearance
NOTICE: Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively
referred to as "fees/exactions:' You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must
follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for
processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, V
review, set aside, void, or annul their imposition. V V
You are hereby FURTHER NOTIFIED that your right td protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity V
changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any
fees/exactions of which you have previously been given p NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired.
-
'PERMIT APPLICATION
CITY OF CARLSBAD BUILDING DEPARTMEN1
1635 Faraday Ave., Carlsbad 'CA 92008
FOR OFFICE USE ONLY
PLAN CHECK NO. (1(307 1
EST. VAL. 2-3S
Plan Ck. Deposit,"
.
. . Validated By_
Date
NNY - - .
Address (include Bldg/Suite #) Business Name (at this address) Sc LA I of 1ivr 9L..l1+ Leg I Description Lot No. Subdivision Name/Number Unit No. Phase No. Total # of units
- . 209-Ol2-0 4heJJ, Assessor's Parcel # Existing Use Proposed Use T1 ,5ciq,icF ' I .-
Description of Work - . + Q. FT. # pf Stories
- .26 L.F. 0e Jep4g5IN pafr.IIIoN.4 L.. 0 ' INtOj.I. PIfItIOM r4ew e.ect.., HVAc
,Name Address City State/Zip
# of Bedrooms
Telephone #
# of Bathrooms
1 .5_s (e577
Fax#
Name Address Address " State/Zip
LI f .• •••• •_• ---L_p. . I' tol J ? G'J — a i Name Address City 'State/Zip . Telephone #
(Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct alter, improve, demolish or repair any structure, prior to its issuance,
also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law [Chapter 9, commending with
Section 7000 of Division 3 of the Business and Professions Code) or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by
any a plicant for a permit subjects the applicant to a civil oenalty of not more than five hundred dollars [$500)). • ' . r- -r'-i .. - __I .' — — - - - - - - -
Name Address . -efty State/Zip Telephone #
State License # 466554 License Class City Business License # 12. 9) 046, ..- -
Designer NameJ E4 w a I, of f Address 977o Ca 1.1.,iI Cp,,t$'. R4. city State/Zip CA. Telephone #"
State License #46c.4 ' , ' SD,CA. z(z(s;kc) . Oiee ' 92:2 crse)54.8495
Workers' Compensation Declaration: I hereby affirm under penalty of pedury one of the following declarations:
I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work - for which this permit is issued.
I have and will maintain worker's compensation, as required by Section 3700 of the labor Code, for the performance of the work for which this permit is issued. My
worker's compensation insurance carrier and policy number
are:
. '
Insurance Company pjptjnplpl I4niot'i "ifrp (Ala) PolicyNo.4h0. 0722 Expiration Date p1. tiI. oø .
(THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS [$100] OR LESS)
CERTIFICATE OF EXEMPTION: Icertify that in the performance of the work for which this permit is issued, I shall ot employ any person in any manner so as to
become subject to the Workers' Compensation Laws of California.
WARNING: Failure to secure workers' compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thotsand
dollars($100,000), in aidiLion to the cost of compensation, damages are provided for in Section 3706 of the Labor Code, interest and attorney's fees.
SIGNATURE r-'- I_-.._Js DATE 06- o5. o7
---------- I hereby affirm that I 4m exempt from the Contractor's License Law for the following reason: -
I, as owner of the property or my employees with wages as their sole compensation, will d the work and the structure is not intended or offered for sale (Sec. 7044,
Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or
through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of
completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale).
El I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's
License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's
License Law). . . . . ' . •
I am exempt under Section - Business and Professions Code for this reason:
1. I personally plan to provide the major labor and materials for construction of the proposed property improvement 0 YES 0 NO
-
- 2. l (have/have not) signed an application for a building permit for the proposed work.
I have contracted with the following person (firm) to provide the proposed construction (include name / address / phone number/ contractors license number): -
I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone number /
/ontractors license number):
I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone number/ type of work
PROPERTY OWNER SIGNATURE - _. DATE
WHITE: File YELLOW: Applicant PINK: Finance
PERMIT APPLICATION
CITY OF CARLSBAD BUILDING DEPARTMENT
.1635 Faraday Ave., Carlsbad CA 92008.
Page 2of2
9OPLETE Th SECTION FOR NORES1OENTML BUILNG ERMrrS Y, n.,
Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration for or risk management and prevention program under
Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? -0 YES 0 NO
Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? 0 YES 0 NO
Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? 0 YES 0 NO
. 'IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE *
REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT.
COSTRUCTION LENDING AGENCY tJ
I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097(t) Civil Code).' . ,.
f LENDER'S NAME . ' ' ' LENDER'S ADDRESS
I certify that 1. have reed the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all City
ordinances and State laws relating to building construction. I hereby authorize representatives of the City of Carlsbad to enter upon the above mentioned property for inspection
purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGEMENTS, COSTS AND
EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT.'
OSHA: An OSHA permit is required for excavations of 50' deep and demolition or construction of structures over 3 stories in height.
EXPIRATION: Every permit issued by the building Official under the provisions of this Code shall expire by limitation and become null and void if the building àrwork authorized
by such permit is not commenced within 180 days from the date of such permit or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a pen of 180 days (Section 106.4.4 Uniform Building Code)
DATE APPLICANT'S SIGNATURE
:
-
'-•
,_
p
, I S
'. . "•-, _.,. . -*-'-- ,-,-••-- '•• - . ..- .'*.•'
- - --.-•'
- '--- I - • . - '' :.- . S , • ' S. i .-_'.: - .. . • -,- ".-'. q.* •
'5. It • . ' • , - . - I I
'4 : ,,_ • * , , -. •-t ' - - .., '.. ' .. , .
- 0.•-'' - '' •• C
'I "- - * 5-
1 -' - , - . : , - •. . - - ' -,
I
.-"
',•
WHITE File YELLOW Applicant PINK Finance
-- - - - 'S -
. • -
City of Carlsbad
Final Building Inspection
Ark Dept: Building Engineering Planning CMWD St Lute
Plan Check #: Date: 09/06/2007
Permit #: CB071647 Permit Type: TI
Project Name: SPEC SUITE:1921 SF SHELL TO Sub Type: INDUST
OFFICE
Address: 2736 LOKER AV WEST #F
-
Lot: 0
Contact Person: ROBERT Phone: 6199545234
Sewer Dist: CA Water Dist: CA •
Date ft
By:
lsPectedfl
,
1
1V6.cA Inspected: (7 Approved: 1V' Disapproved:
Inspected Date
By: Inspected: Approved: Disapproved:
Inspected Date S
By: Inspected: Approved: Disapproved:
Comments:
I
• S • • S
••
• •
5
•
••
-• - •
•
•
-
•
S
•
S
•
-
•
••
-
City of Carlsbad Bldg Inspection Request
For: 09/18/2007
Inspector Assignment: TP Permit# CB071647
Title: SPEC SUITE:1921 SF SHELL TO
Description: OFFICE
Type: TI Sub Type: INDUST
Job Address: 2736 LOKER AV WEST
Suite: F Lot: 0
Location:
OWNER FENTON H G COMPANY
Owner:
Remarks:
Total Time:
CD Description Act Comments
19 Final Structural
29 Final Plumbing
39 Final Electrical
49 Final Mechanical
Phone: 6199545234
inspector:
Requested By: ROBERT
Entered By: CHRISTINE
Comments/Notices/Holds
Associated PCRs/CVs Original PC#
Inspection History
Date Description Act lnsp comments
09/07/2007 89 Final combo co TP SEE JOB CARD
08/30/2007 14 Frame/Steel/Bolting/Welding AP TP T-cElL
08/30/2007 34 Rough Electric AP TP CElL LITES
08/30/2007 44 Rough/Ducts/Dampers AP TP DUCTS
08/29/2007 14 Frame/Steel/Bolting/Welding co TP T-CEIL
08/17/2007 17 Interior Lath/Drywall AP PD
08/16/2007 21 Underground/Under Floor AP TP p.o.c.
08/10/2007 14 Frame/Steel/Bolting/Welding AP TP ROOF REINF. FOR H P UNIT.
08/10/2007 14 Frame/Steel/Bolting/Welding AP TP DMZ WALL
08/10/2007 21 Underground/Under Floor AP TP WASTE TO, BUT N/INCL P.O.C.
08/10/2007 24 Rough/Topout AP TP
EsGil Corporation
In Partners/lip with government for Bui(ding Safety
DATE: July 6, 2007
JURISDICTION: Carlsbad.
PLAN CHECK NO.: 07-1647 SET: II
PROJECT ADDRESS: 2736 Loker Avenue West, Suite "F"
PROJECT NAME: Spec Suite
g-AR&LCANT
o JURIS.
U PLAN REVIEWER
O FILE
The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes.
II The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff.
LI The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
The check list transmitted .herewith isfor your information. The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck.
LI The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
El The applicant's copy of the check list has been sent to:
Esgil Corporation staff did not advise the applicant that the plan check has been completed.
LI Esgil Corporation staff did advisethe applicant that the plan check has been completed.
Person contacted: •• Telephone #:
Date contacted: (by: ) Fax #:
Mail Telephone Fax In Person
LI REMARKS: .
By: Bryan Zuppiger • Enclosures:
Esgil Corporation
OGA 0MB LIEJ LIPC 06/28/07
trnsmtl.dot
S
9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax(858)560-1576
EsGil Corporation
In(Partnership with çovernment for Bui(ding Safety
DATE: June 25, 2007 . U APPLICANT
JURISDICTION: Carlsbad
0 FILE
PLAN CHECK NO.: 07-1647 SET: I =
PROJECT ADDRESS: 2736 Loker Avenue West, Suite "F"
PROJECT NAME: Spec Suite
The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes.
LII The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff.
LI The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
. The check list transmitted herewith is for your information. The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck.
The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
The applicant's copy of the check list has been sent to:
Jaci Edwards
9770 Carroll Center Road, Suite "C"
San Diego, CA 92126
EJ Esgil Corporation staff did not advise the applicant that the plan check has been completed.
Esgil Corporation staff did advise the applicant that the plan check has been completed.
Person contacted: )aci Edwards Telephone #: 858 549 8455
Date ) Fax #: 858 530 1779
Mail Telephone / Fax Person
Lii REMARKS:
By: Bryan Zuppiger Enclosures:
Esgil Corporation
E:IGA EMB []EJ [:1 PC 06/18/07
trnsmtl.dot
9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax(858)560-1576
Carlsbad 07-1647
Juiie 25, 2007
PLAN REVIEW CORRECTION LIST
TENANT IMPROVEMENTS
PLAN CHECK NO.: 07-1647
OCCUPANCY: B/S2
TYPE OF CONSTRUCTION: VN
SPRINKLERS?: yes
DATE PLANS RECEIVED BY
JURISDICTION:
DATE INITIAL PLAN REVIEW•
COMPLETED: June 25, 2007
FOREWORD (PLEASE READ):
JURISDICTION: Carlsbad
USE: office
ACTUAL AREA: 1921 ft2
OCCUPANT LOAD: unknown
DATE PLANS RECEIVED BY
ESGIL CORPORATION: 06/18/07
PLAN REVIEWER: Bryan Zuppiger
This plan review is limited to the technical requirements contained in the Uniform Building Code,
Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws
regulating energy conservation, noise attenuation and access for the disabled. This plan review is
based on regulations enforced by. the Building Department. You may have other corrections based
on laws and ordinances enforced by the Planning Department, Engineering Department, Fire
Department or other departments. Clearance from those departments may be required prior to the
issuance of a building permit.
Code sections cited are based on the 2001 CBC that adopts the 1997 UBC.
The following items listed need clarification, modification or change. All items must be satisfied
before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3, 1997
Uniform Building Code, the approval of the plans does not permit the violation of any state, county or
city law.
To speed up the recheck process, please note on this list (or a copy) where each correction
item has been addressed, i.e., plan sheet number, specification section, etc; Be sure to
enclose the marked up list when you submit the revised plans.
TENANT IMPROVEMENTS WITHOUT SPECIFIC ENERGY DATA OR POLICY SUPPLEMENTS (1997uBc) tiforw.dot
Carlsbad 07-1647
June 25, 2007
. PLANS
Please make all corrections on the original tracings, as requested in the correction list. Submit
three sets of plans for commercial/industrial projects (two sets of plans for residential projects).
For expeditious processing, corrected sets can be submitted in one of two ways:
Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad
Building Department, 1635 Faraday Avenue, Carlsbad, CA 92008, and (760) 602-2700.
The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering
and Fire Departments.
Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320
Chesapeake Drive, Suite 208, San Diego, CA 92123, and (858) 560-1468. Deliver all
remaining sets of plans and calculations/reports directly to the City of Carlsbad Building
Department for routing to their Planning, Engineering and Fire Departments.
NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the
City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete.
2. In addition to the information shown on the plans, specify on the first sheet of the plans
indicate:
Present and proposed occupancy classifications of the remodel area; the warehouse is
probably a S2.
' The occupant load of the remodel area(s). Please include the warehouse.
Please uncross detail 4/D-1 or reassign the balloons on sheet A-i.
Provide mechanical ventilation in all rooms, capable of supplying outside air at a minimum rate
of 15 cubic feet per minute per occupant. UBC Section 1202.2.1. Warehouse?
WIRING METHODS: AC Cable is not allowed in A, B, E, H, and I occupancies. NM cable is
restricted (without City approval) to one and two family dwellings. Note on plans that an
equipment ground conductor is to be installed in all flexible conduits.
The use of flexible metal conduit as a grounding means must comply with City Policy 84-36.
7.. No wiring is permitted on the roof of a building and wiring on the exterior of a building requires
approval by the Building Official. City Policy.
Show that at least one water closet fixture, located in a compartment, shall provide the following,
per CBC Section 1115B.7.1.3:
a) The other side of the water closet shall provide 18" from the centerline of the water closet
to the wall. See 4/TS-2.
Show that accessible lavatories comply with the following, per CBC Sections 1115B.2.1.2:
a) When lavatories are adjacent to a side wall or partition, there shall be a minimum of 18" to
the center line of the fixture to the wall. See 4/TS-2.
Carlsbad 07-1647
June 25, 2007
The person responsible for their preparation must sign all final sheets of plans. (California
Business and Professions Code).
To speed up the review process, note on this list (or a copy) where each correction item has
been addressed, i.e., plan sheet, note or detail number, calculation page, etc.
The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive,
:Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the
plan review for your project. If you have any questions regarding these plan review items,
please contact Bryan Zuppiger at Esgil Corporation. Thank you.
Carlsbad 07-1647
June 25, 2007
VALUATION AND PLAN CHECK FEE
JURISDICTION: Carlsbad PLAN CHECK NO.: 07-1647
PREPARED BY: Bryan Zuppiger DATE: June 25, 2007
BUILDING ADDRESS: 2736 Loker Avenue West, Suite "F'
BUILDING OCCUPANCY: B TYPE OF CONSTRUCTION: VN
BUILDING
PORTION
AREA Valuation
(Sq. Ft.) Multiplier
Reg.
Mod.
VALUE ($)
ti 1921 . 34.37 66,025
Air Conditioning
Fire Sprinklers
TOTAL VALUE 66,025
Jurisdiction Code ICb IBY Ordinance I
I $410.511 Bldg. Permit Fee by Ordinance V
Plan Check Fee by Ordinance [j •1 $266.83 I
Type of Review: EI1 Complete Review D Structural Only
0 Repetitive Fee 0 Other Repeats . 0 Hourly I HOur*
Esgil Plan Review Fee I $229.89
Comments:
macvalue.doc
I I A
4 Carlsbad
ABUI 'P' :
DATE:IP/a /07 PCECNO.: t87 I 7 BO LUNG ADDESS: 7 LW! ,A AJ ( '
PROJECT D.ESORIPTION:
RSSESSORSPARC'ELNUMBER.
ENG1NEf RING DEPARTMENT
APPROVAL
The item you have submitted for review has been PJease see the attached report of deficiencies
.approved. The approval .is based on plans, marked with :0. take necessary cori-ections4o plans
information and/or specifications provided in your or specifications br compliance with applicable
submittal; therefore any changes to these itemsafter codes and standards. Submit corrected -plansand/or
this date, including field modifications, must sbe •'specifications'tothisffice for review. -reviewed by this office to insure continued
conformance with applicable codes. Please review
carefully all comments -attached, -as failure to comply
with instructions in this report can result in
suspension of permit to build.
By:
.LI A -Right-of-Way permit is required prior to
construction of the following improvements: By.
By:
FOR OFFICIAL USE ONLY
EN INEERING AUTHORIZATION TO 4SS0€ .O4JILDING PER
By: :Date:
Date:
Date:
Date:
.ATTACHMENTS -
Li Dedication Application
El Dedication Checklist
Li Improvement Application
LI Improvement Checklist
El Future Improvement Agreement
El Grading Permit Application
Li 'Grading Submittal Checklist
El -Right-of-Way Permit 'Application
El Right-of:Way Permit Submittal -ChekIisl
-and lnforrr.ation 'Sheet
Li SewerFee -InfoDation'St'eet
ENGINEERING DEPT. CONTACT PERSON
Name: LinàOntivei-os
'CityofCaiisbad
Address: t635 'Faraday Avenue. Car! sbad,-CA 92008
Phone: 4760) 602.2773
CFD INFORMATION
Parcel 'Map No:
tots:
Recordation:
Carlsbad Tract:
1635 !Faraday :Aven&ie .Gactsbad. CA -731'4 • (760)'602-2720 • FAX (70);6O2'8562 AM
0LD1. NGPtN'C 4 1€C4( CHE11QtST
S1TE1'LA'N
1. 'Provide .a fu4y4icnensioned site pIandrawn4o sca4e. 'Show:
A. NoithArrow - F. Right-of-Way Width'& Adjacent -Strieets
8. Existing .& 'Pi'oposeStuctures 'cG.Diiveway widths
Existing Street Improvements H. Existing or4proposed sewer 1ateral
Property Lines - I. Exis'ting'orpro.posed 'wa(er'service
Easements J. Exisiting or pcoposed inlgätion'seM:ée
2. Show on site pIan:
.
A. Drainage Patterns
Building pad surface drainage must maintain -a minimum slope of one
percent towards -an adjoining street'oran approved draiiae course.
ADD THE FOLLOWING NOTE: "Finistigrade will ;provide .,a minimum tpositive
drainage of 2% to.swa'le5'away'frotmbuilding."
B. Existing -& 'Proposed 'Slopes and Topography
C. Size, type, location, alignment of existing 'or-propoed sewer and 'water-service(s)
that serves the project. Each unit requires -a separate service, however, -second
dwelling units and apartment complexes are an 'exception.
0. Sewer and water tater-ais should.-not be located with inpropcsed.veways, per
standards.
3. Include on 'title sheet:
Site address
Assessor's Parcel Number
Legal Description
For comnerciaWindusti-al buildings and $enant improecnent pnojecs, include-
total 'building soijare -footage with the souace footage for eaoh dieient use
existing sewer permits showing-square footage of otiferent iuses (manufactunng,
warehouse, dffioe ,etc:) previously pproved. :
EXISTING PERMIT NUMBER OEScR4PTIN
' 2 hev. 71'4UJ
3111D D1'SCRETIONARY APPROVAL COMPLIANCE
0 0 4a. -Project does not comply with the4ollowkg Engineering Conditions of approv.aI4r
/ 'Pcoject-'No.______________________________________________________
0 0 4b. All conditions -are in compliance. Date:
DEDICATION REQUIREMENTS
0 5. Dedicion 'for all-street Rights-of-Way adjacentlo the building sitè -andnytor
/ drain or utility easements on the -building site-is required for4a11 new buiidings-and
/ for remodels with a vakie at or -exceeding 315000 , pursuant-b .Calsbad
/ Municipal Code Section 18.40.030.
Dedication required aslollows: -
Dedication required. Please have •a registered Civil Engineer 50r Land Sureyor
prepare -the appropriate legaldescription together with an-8 '/2" x 11" plat map-and
S / submit with a title report. All easement docurn, ents must-be approved and -signed
by owner(s) prior to issuance of Building Permit. -Attached please Iind an
application forand submittal -checklist for the 'dedication -process. Submit 4he
-completed application form with -'the required -checklist Items and 'fees -to 4e
- Engineering Department in person. Applications will not be accept by-mail orfax.
Dedication completed-by: Date:
IMPROVEMENT REQUIREMENTS' S
,)-•o 0 6a. All needed public improvements upon and adjacent-to the buiding -site must-b,e
f constructed at time of building construction Whene'er -the vaue of --the-
construction exceeds 575.000 pursuant to-CartsbadMuni.cipalCode-'Section
- 18.40.040.
- . Public improvements required-as-follows:
Attached please find an application -form and submittal checklist--for the public
improvement requir-ements A registered Civil Engineer must prepare the
- - appropriate improvement -plans and submit -tl)ern 'together with the equiremen:ts
on 'the attached checklist lo -the Engineering Department Ithrougha -separate -plan
O •
S
-check -process. -The-completed -application-form-and the-cequirementsn the
h%9UINPANEC'FORMaoc S • "' '"°°
tNGRLNCHEOC'IEC4L4S
1ST 2ND 3RD
chedc4ist must be submitted in person. Applications by ail or tfax ..aieit
accepted. Improvement plans must be approved, appropriate -secuñties posted
and fees paid 1prior 40 issuance of building permit.
Improvement Plans signed by: Vate:
0 0 6b. Construction of the public improvements may be deferred p.ursuani 4o Carlsbad
(Municipal Code Section 18:40. Please-submit a recent property title ceportor
current grant deed on the prop.ey and processigfee of 1310 so wemay
prepare the necessary Neighborhood Improvement 'Agreement. This agceert
must be signed, notarized and approved by 'the City prior 'to issuance 'of a
Building permit.
Future public improvements required as follows:
D 0 6c.'Enclosed please find your Neighborhood Improvement Agreement. Please return
agreement signed and notarized to the iEngineenng Department
. . Neighborhood Improvement
Agreement completed by:
Date: .
0 6d. No Public Improvements required. SPECIAL NOTE: Damaged .or defective
improvements iound adjacent 10 building site must be repaired to the satisfaction
of the City Inspector prior to occupancy. .
GRADING PERMIT REQUIREMENTS
The conditions that invoke the need 'for a grading permit are 4ound in tSection
11.06.030 of the 'Municipal Code.
7a. Inadequate information available on Sile IPIan4o make adetermination.on grading
.
requirements. Include accurate erading quantities4cut,fiII import, expr*).
0 0 7b. Grading Permit ceqtired. A separate .gr.ading plan prepared by.a cegistejed Civil
Engineer must be submited together with the completed application -form
f .. attached. NOTE: The Grading Permit must be issued and cough qrading
anproval. obtained .prioro issuance of,a Building Permit.
Crading.Inepectorsign off by:
0' 7c.;Graded 'Pad Certification required. 'Note: Pad'ce(Iification nay be'req.uired even
ifagadingperiisc'iotrequired.)
Ci1(UILaiPLs.NIED, OiFORMoc
. ..
Se. 7:,14'
8ULD1NG PLANCHEC4( CHECKLIST
1S1 2ND 3RD
- 7.d .NoGrading Permitcequied.
0 0 0 7e. If grading is not required, write NoGrading" onp1otpian.
MISCELLANEOUS PERMITS S
0 0 8. A RIGHT-Of -WAY PERMIT is requfred 40 do .work 'in City RigtitofWay and/r.
private work adjacent -to the public Right-of-Way. Types-of wok include, but .ace
not limited to street improvements, tree trimming, driveway construction, tying
into public storm drain, sewer and water utilities.
Right-of-Way permit required for
0 , 0 9. INDUSTRIAL WASTE PERMIT If your facility is located in 4he City-of -Carlsbad
sewer service area, you need to contact 'the Carlsbad Municipal 'Water D.istcjct,
' located at 5950 El -Camino Real, Carlsbad, CA 92008. District'personnel can
provide forms and assistance, and will check to see if your 'businessenterprise '.is
on the tWA Exempt L.i'st. You may 'telephone (760) 43'8-2722, extension 7153,
for assistance.
Industrial Waste permit accepted by:
Date:
/4\D 0 10. NPDES PERMIT
Complies, with the City's requirements of... National 'Pollutant Discharge
Elimination System -(N'POES) permit. The applicant 'shall -provide test
management practices to reduce surface pollutants. toan acoeptable level prior to
discharge to sensitive areas. "Plans -for 'i.th improvements slall be appvove'dby
the City Engineer prior to issane.of grading r'building permit, whichever
occurs first.
ii.. Q 'Required fees are attached S
0 Note-es required . S
WATER METER REVIEW'
0 0 1.2a. Domestic..potabie)Use
Ensure that the meter proposed by the ownerIdeveoper •is not 'over-sj.z-ed.
S S Oversized meters are inaccurate during low-flow conditions. If it is oversized,4o
- 'the iife'of tthe 'meter, the City will not .accurately biII 4he'owner for the 'waterused.
All'sin1e familyweBing unts cecei-ed 'standa 1 ervice with 58 eiee'.
C Sa sw teILIW. P.W,l-CCLE FOW oo ,
BthL1JlNG PLA1C4€CK CHEC+(L4ST
1ST •2 3R0
if owner/deveioper proposes a size other 'than the standard", nthn
'owner/developer must 'provide potable water deman'd cacu(a4o'ns,
•whch include 'total 41xture counts and maximumwater demaQd in.gailo.s
per 'minute (gprn). rA typical 'fixture count and water deman'd worksheetis
attached. Once the gpm is provided, check against the "meter 'sizing
schedule" to verify"the anticipated inetersizeor the unit.
Maximurnserviceand netersizes.a2" service 'witha 2"meter.
If a developer is proposing a meter greater than 2", sugges't Abe
installation -of multiple 2" services as needed 4t0 'provide the anticipated
demand. manifolds are considered 'on case by case basis ,4o "limit
multiple trenching into the street).
D 0 12b. Irrigation Use (where recycled water is not available)
All irrigation meters must be sized via irrigation .calcuiations'<in gpm)rior
to approval. The developer must provide these calculations. Please follow
these -guidelines:
1. If the project is a newer -deveJopment (newer than 1998), check the iecent
improvement plans and observe if-the'new irrigation service is reflected on
the improvement sheets. If so, at --the water ieter station, 'the demand :in
gpm may 'be listed there. Irrigation services are "listed with a circled '1",
and potable water is typically .a circled "W". The. irrigation service "4'Oüid
look like:
STA 1+00 Install 2" service and
1.5: meter (estimated 100 gpm)
2. If the improvement plans do not list the irrigation meter and '4he
'service/meter will be installed via another instrument such as -the 'budding
plans or grading 'plans (w/ a ri4it of way permit of. course), then 4he
applicant must provide irrigation calculations. . for estimated worst-case
irrigation demand (largest zone with the "facthest reach). Typically,-Lamy
Black has .already reviewed this if landscape piaRs heMe been 'prepared_
but the applicant must provide The calculations 'to 'you for your use. 'One'
you have received .a good .exampieof irrigation calculations, keep a'set$pr
your reference. in general thecalcuia'tionswilllnclUde:
Hydraulic grade line
Elevation at point of connection (POC)
.. Pressure-at POC in pounds 'per 'square inclv(PSI)
'. 'Worse case zone *largest, farthes( -away -from valve
Total Sprinkler heads 'listed (with gpm se 'ter bead)
Include a 10%i-es'id.ual pressure at point oIconnection
, 3. In general, ;all major sloped areas of .-a suMivisionproj'ect are 4o "e
irrigated v a separate irrigationtime4em unless the project is only 'SF1) with
o OA). As, long as"the prjectis o.càted wih khéC cc'ed 't
4BUQOPtAN.c4i€OK;CHEC<LST
,S1 2 ND 3R0
service boundary, the City intends r.on swiching these irrigation
servicesfmeei-s 40-a knew recycled water 11ne in -the'fu'ture.
D D 12c. Irrigation 4Jsé (where recycled water 1savaitable)
Recycled water meters are sized the same as-the irrigation meter-above.
If a project fronts -a street with recycled water, -Then --they should be
connecting to this line to irrigate slopes within -the de-ve1opment. 'fuor
subdivisions, This should have been -identifled, .and implemented on -the
improvement plans. Installing -recycled water -meters is a be-nefl forthe
applicant since they are exempt-from paying the San DiegotoUnty 'Water
Capacity -fees. Howeyer, if they front -a street which -the recycled water -is
There, but -is not live (sometimes they. are charged -with çotable --water--until
recycled water is available), then the applicant must pay the SanDiego
- Water Capacity Charge. If within three years, the recycled water ne is
charged with recycled water by CMWO, -then-the applicant can apply for a
. •..refund to the San Diego County Water AuthoritySDCWA) 'for a refund.
- -However, -let the applicant know that -we cannot guarantee the--refund, -and
-
. they must deal with the -SDCWA1àr this.
0 13 naI C
--
-
ENGINEERING DEPARTMENT
FEE CALCULATION WORKSHEET
VCalcu*lation
timate based on unconfirmed information from appli nt.
based on building plancheck plan submittal.
~77Address: _T)2) iQ(E(3 I' Bldg. Permit No. 4? 7i I
Prepared by: Date:YfZ'V(V ( Checked by: , Date:
Wvp~~V L51 EDU CAL CULATIlS: List types and square footages for all use(~~
Types of Use: Sq. Ft./Units: ED U's:
Types of Use: Sq. Ft./Units: EDU's:
ADTCALCULATIONS: List types and square footages for all useT
Types of Use: - Sq. Ft/Units: ADT's:
Types ofof Use: - Sq. Ft./Units: ADT's:
FEES REQUI RED:
WITHIN CFD: ((no bridge & thoroughfare fee in District #1 reduced Traffic Impact Fee) 0 NO
0 1. PARK-IN-LIEU FEE PARK AREA & #:
,-FEE/UNlT:
.
X NO. UNITS: . =$___________
E1rRAFFIC IMPACT FEE n . i'-)4) 11 • j jtf-ADTs/UMTS 2v,, X FEE/ADT /" =$
3. BRIDGE AND THOROUGHFARE FEE (01ST. #1 DIST. #2 DIST. #3
('f)yTs/UNrrs__ '
4. FACILITIES MANAGEMENT FEE . ZONE: _
V/5.
UNIT/SQ.FT.:. X FEE/SQ.FT./UNIT:_______ =$__________
5.SEWERFEE S
ED U's: X FEE/EDU:110'-L7
ca)DBENEFIiAREA:t
(EDuS\4.b X FEE7EDU___ = 522
0.... 6SEWER.LATERAL ($2,500) - S. . = .\ 7. DRAINAGE FEES PLDA LNNHIGH /LOW t )
ACRES: X FEE/AC: =$_____________
8. POTABLE WATER FEES . . .
UNITS CODE CONNECTION FEE METER FEE SDCWA FEE IRRIGATION
lof2 H:\Development Services\MASTERS\FORMS -MISCELLANEOUS .\FEE CALCULATION WORKSHEET.doc S Rev. 7/14/00
r
-
ENGINEERING DEPARTMENT
FEE CALCULATION WORKSHEET
El 9:RECCAiMED WATER FEES
UNITS CODE CONNECTION FEE
-
' METER FEE '
,•', •4••" V
TOTAL OF ABOVE FEES*: $_________________
*NOTE: This calculation sheet is NOT a complete list of all fees which maybe due.
Dedications and Improvements may also be required with Building Permits.
" t-OVi
IP2-
2 of 2
H:\Developrnent Sevices\MASTERS\FORMS -\MISCELLANEOUS -\FEE CALCULATION WORXSHEET.doc Rev. 7/14/00
PLANNING DEPARTMENT
* BUILDING PLAN CHECK REVIEW CHECKLIST
T% Plan Check No. CB 07 I Address 73( LOkLi,,A u ) Planner Chris Sexton Phone (760) 602-4624
APN:bq"OSI -al
Type of Project & Use:cSfY.. ltk*.LNet Project Density: DU/AC ° ZoningPY1 General Pan: PT Facilities Management Zone:
• CFD (in/out) #_Date of participation: Remaining net dev acres:______
. . (For non-residential development: Type of land used cre
a
t
e
d
b
y
t
h
i
s
Circle One
permit:_________________________________________________________
_
_
_
Legend: Item Complete 0 Item Incomplete - Needs your action
. V 0 0 0 Environmental Review Required: YES NO TYPE • DATE OF COMPLETION: .
• Compliance with conditions of approval? If not, state conditions whic
h
r
e
q
u
i
r
e
a
c
t
i
o
n
.
Conditions of Approval:
V
V IZ1'O 0 V
V
Discretionary Action Required: YES
-NO 'TYPE VV
APPROVAL/RESO. NO. DATE _____ •
V
PROJECT NO. V V V•
V
V V OTHER RELATED CASES:
V
Compliance with conditions or approval? if not, state conditions which
r
e
q
u
i
r
e
action.
V V Conditions of Approval:
S
EJ'1i 0 Coastal Zone Assessment/Compliance V
V
Project site located in Coastal Zoie? YES" NO i' CA Coastal Commission Authority? YES NO If California Coastal Commission Authority: Contact__ th— em at - 7575 Metropolitan Drive, Suite 103 San Diego CA 92108-4402; (619) 767-2370
V V V V Determine status (Coastal Permit Required or Exempt):
LU :0 I I . 5 4• 4
. - • •
V
Habitat Management Plan' Data-Entry Completed? YES NO t- If property has Habitat Type identified in Table 11 0f HMP,1complete HMP Permit application and assess fees in Permits Plus
, -
• (AIP/Ds, Activity Maintenance, enter CB#, toolbar, Screens, HMP
F
e
e
s
,
E
n
t
e
r
A
c
r
e
s
o
f
H
a
b
i
t
a
t
T
y
p
e
impacted/taken, UPDATE!) - V • •
V
V
V
V ]'1J 0 inclusionary Housing Fee required: YES NO VI
V
(Effective datèof lnclusionary Housing Ordinance
- May 21, 1993.).
•
-
'
Data Entry Completed? YES
* NO (A/P/Ds, Activity Maintenancerenter CB#, toolbar, Screens, Housi
n
g
F
e
e
s
,
C
o
n
s
t
r
u
c
t
H
o
u
s
i
n
g
Y
/
N
V - Enter Fee, UPDATE!)
H:ADMiN\COUNTER\BidgPInchkRevChkist V
- ,• • V - •
V Rev 3/08
Policy 44— Neighborhood Architectural Design' Guideline's
Applicability: YES NO 1
Project complies YES _NO________
Zoning:
Setbacks: .
Front: Required Shown
Interior Side: Required Shown
Street Side: Required Shown
Rear: Required Shown
Top of slope: Required .Shown
Accessory structure setbacks:
Front: Required Shown
Interior Side: Required J Shown
Street Side: Required (- Shown
Rear: Required Shown
Structure separation: Required Shown
Lot Coverage: Required A)/ 1i Shown
Height: Required Shown
Parking: Spaces Required Shown
(breakdown by uses for commercial and industrial projects required)
Residential Guest Spaces Required Shown
11
Site Plan:
Provide a fully dimensional site plan drawn to scale. Show: North arrow, property lines, easements,
existing and proposed structures, streets, existing street, improvements, right-of-way wid
t
h
,
dimensional setbacks'and existing topographical lines'(1iiluding all side and rear yard slopes)..
Provide legal description of property and assessor's parcel number.
- M
"1 '--
OK TO ISSUE AND ENTERED APPROVAL INTO COMPUTER cs DATE
H:\ADMINCOUNTERBtdgPInchkRevChktst
Rev 3/06
Carlsbad Fire Department
Plan Review Requirements Category: TI , INDUST
Date of.Report: 06-19-2007
Name: -,
Address:
BLDG. DEPT COPY
Reviewed by:Z 1 5
Permit #:CBQ71647
Job Name: SPEC SUITE: 25LF DIMISING PART
Job Address: 2728 LOKER AV WEST CBAD St: F
J4!'I1t41DI T'Tj' The item you have submitted for review is incomplete. At this time, this offia
adequately conduct a review to determine compuui =AW -
carefully all comments attached P1.'.- L11 iiessary plans and/or specifications, with d
L.. IU1 ievlew and approval.
*
* Conditions:
-
Cond: CON0002 162
[MET] S
APPROVED:
THIS PROJECT HAS BEEN REVIEWED AND APPROVED FOR THE PURPOSES OF ISSUEANCE OF A
BUILDING PERMIT.
THIS APPROVAL IS SUBJECT TO FIELD INSPECTIONS, ANY REQUIRED TESTS, FIRE DEPARTMENT
NOTATIONS,
CONDITIONS IN CORRESPONDENCE AND COMPLIANCE-WITH ALL APPLICABLE CODES AND
REGULATIONS. -
THIS APPROVAL SHALL NOT BE HELD TO PERMIT OR APPROVE ANY VIOLATION OF THE LAW.
Entry: 06/19/2007 By: MS Action: AP S
/
• 5,