HomeMy WebLinkAbout2738 LOKER AVE W; ; CB950099; Permit4 • B U I L D I N G P E R N I T - Permit No: CB950099
06/09/95 14:19 Project No: A9500117
Pacré. 1 of 1 Development No:
JobAddress: 2738 LOKERAV WEST Suite:
Permit Typ INDUSTRIAL TENANT IMPROVEMENT -
Parcel No: • - Lot#:
Valuation: 55,484
'Construction Type: VN
Occupancy Group: 8-2 Reference#:; Status: ISSUED.•.
Desription: WAREHOUSE TO OFFICE 1700 SQ FT - Applied: 01/12/95
: 434 SF TI ALSO Apr/Issue: 06/09/95
- Entered By: RMA
Appl/Ownr : CARLSBAD CROSSROADS LTD 619-431-7233
2734 LOKER AV WEST
CARLSBAD CA 92008 . •
------------------------ * * Fees Required --* lec ted& Credits
Fees: 4,4f2.0 'Q),
Adjustments: I? .00/ .00
Total Fees: 4-4\00- 270:00 Z. Balaeu3,\ 4,142.00
Fee
442
------------------ description
__
fee Data
Builing Perm
Plan:Check 1:ee
fr(
287.00
Enter Number of1EDUs_WaF
198.00
Z
> 1440.00
W
£
V.
1952
: 1.4259:00
Enter '1 for Plumbing Isi &1 0 / 20.00
Eádh Plumbing Fixture or Tr 4,./ 7.00 28.00
Each Install/Repair Water Line-.. 74.00 7.0,0
Each Water Heater and/or Vent > 1 7.00 - 7.00
Gas Piping System > 1 • 7.c50 . . 7.00
*-PLUMBING TOTAL S ' - 69.00.
Enter fly for Electric Issue Fee > 10.00 Y
Remodel/Alter Per AMP 200 •' .25 . 50.00
* ELECTRICAL TOTAL . . 60.00
Enter 'Y' for Mehanical Issue Fee> 15.00 Y
Install Furn/Ducts/Heat Pumps > 1 9.00 9.00
* MECHANICAL TOTAL 24.00
S
- jN:P.
- -• CITY OF CARLSBAD L1
2075'Las Palmas Dr., Carlsbad, CA p2009 -(
F 11 'APPROVAL
DATE
61 41 P
-_______
: ••
2256 0669/95 01 02
4
• -, - - I 4142..00
PERMiT APPLICATION '-
City of Carlsbad Building Department !I1
2075 Las Patinas Dr., Carlsbad, CA 92009 (619) 438-1161
From List 1 (see back) give code of Permit-Type:
For Residential Projects Only: From List 2 (see back) give
Code of Structure-Type:
Net Loss/Gain of Dwelling Units
'3LJf)
PLAN CHECK NO.
EST. VAL - -
PLAN CK DEPOSIT •.:. 0
VALID. BY b.
DATE
0269 01/12/95 0001 01 02
C-PRMT 270.00
PROJECT INFORMATION FOR OFFICE USE ONLY
51 n or Suite No. Address Z73'
Nearest Cross Street ~O= alt-z~,
Unit No. Phase No. LEGAL DESCRIPTION Lot N 9. Subdivision
__&-
uboi n Na
41 (32/ /-tcf /Q 3 7
CHECK BEWW IF SLJMIrfID:
02 Energy Calcs 02 Structural Calcs 02 Soils Report DI Addressed Envelope
ASSESSOR'S PARCEL 4fL4..!k!/ -24 7—E)'1 EXISTING USE PROPOSED USE
DESCRIPTION OF WORf( ______ 23
SQ. FT. /'700 4 OF STORIES / # OF BEDROOMS # OF BATHROOMS
WN SALT PESUN (ii dilteremt Irom applicant
NAME (l a name first) el /s4 Z 73
CITY J ATATE 04 ZIP CODE ?92DAY TELEPHONE £
NAME (last name first ADDRESS
CITY A—A TATE ZIP CODE DAY TELEPHONE
5. PROPERTY OWNER
NAME (last name first) ADDRESS
CITY STATE ZIP CODE DAY TELEPHONE
0. L"14 Lt(JtL1tJIt
NAME (last name fi39 Veil //t
STATE ZIP CODE DAY TELEPHONE
STATE UC. # LICENSE CLASS CITY BUSINESS UC. #
Workers' Compensation Declaration: I hereby affirm that I have a certificate of consent to sell-insure issued by the Director of Industrial
Relations, or a certificate of Workers' Compensation Insurance by an admitted insurer, or an exact copy or duplicate thereof certified
by the Director of the insurer thereof filed with the Building Inspection Department (Section 3800, Lab. C).
INSURANCE COMPANY POLICY NO. EXPIRATION DATE
Certificate of Exemption: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner
so as to becom 'ubject to the Workers' CompenqOn Laws of California.
SIGNATURE
I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or
offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds
or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended
or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden
of proving that he did not build or improve for the purpose of sale.).
0 1, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions
Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects
with contractor(s) licensed pursuant to the Contractor's License Law).
0 I am exempt under Section Business and Professions Code for this reason:
(sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish, or repair
any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the
provisions of the Contractor's License Law (Chapter 9, commencing with Section 7000 of Division 3 of the Business and Professions Code)
or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit
subjects the applicant to a civil penalty of not more than five hundred dollars [$500)).
SIGNATURE DATE
COMPLETE THIS SEC11ON FOR NON-RESIDENTIAL BUILDING PERMITh ONLY:
Is the applicant or future building occupant ruired to submit a business plan, acutely hazardous materials registration form or risk management and
prevention program under Sections 2550525533 or 25534 of the Presley-Tanner Hazardous Substance Account Act?
YES kNo
Is the applicant or future building occupa
YES
p4uired to obtain a permit from the air pollution control district or air quality management district? G'Nçy
Is the facility to be constructed within I,0 feet of the outer boundary of a school site?
DYES 0NO
IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED AFTER JULY 1, 1989 UNLESS THE APPLICANT
HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DIsTIUcr.
eret)y affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec 3097W Civil Code).
LENDER'S NAME LENDER'S ADDRESS
10. APPUCAN CEWIIFICAI1ON
I certify that I have read the application and state that the above information is correct. I agree to comply with all City ordinances and State laws
relating to building construction. I hereby authorize representatives of the City of Carlsbad to enter upon the above mentioned property for inspection
purposes. I ALSO AGREE TO SAVE INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS COSTS
AND EXPENSES WHICH MAY IN ANY WAY A(XIRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT.
OSHA An OSHA permit is required for excavations over 5'0' deep and demolition or construction of structures over 3 stories in height.
Expiration. Every permit issued by the Building Official under the provisions of this Code shall expire by limitation and become null and void if the
building or work authorized by such pemit is not commenced within 365ays from the date of such permit or if the building or work authorized by
such permit is suspended or abando e'at any time after the work i(jpfnenced for a period of 180 days (Section 303(d) Uniform Buildig Code).
APPLICANT'S SIGNATURE , , DATE: 1-12 5
0
247
. . S .. S
Permit No: SE950003
06/09/95 14:28 - S Project No: A9500117
Page 1 of 1 Development No:
Job Address: 2738 LOKER AV WEST •. . Suite:
Permit Type: SEWER - OFFICE/WAREHOUSE
Parcel No: Lot#:
Valuation: .0
Cohstruction Type:
Occupancy Group: . Reference#: CB950099 Status: ISSUED
Desciption: WAREHOUSE TO OFFICE 1700 SQ FT Applied: 01/17/95
- : • .. Apr/Issue: 06/09/95
Entered By: HE
Resp Party: .CARLSBAD CROSSROADS LTD . 619-431-7233
2734 LOKER AV WEST .
CARLSBAD CA 920081 -
Fees Required Co ected & CreditsAn - **
Fees: if 1 4 i
S 'Adjustments.: - t•0 - - Totà1 , .00
Total Fees: f3 00", .00
Bala nçè'aDté,:. 1,130.00
Fee description /L
. Units \'c4'e)L1 nit Ext fee Data I '' V' \
<Enter CREDIT EDUsX 34 34:
Total Ebus .60
Sewer Fee
SEWER 'TOTAL 1130. 00
• INCORPORATED - 1952
IK
S . -
1,
S .
• 2256 06/09/95 0001 01 02
C-PRHT 113000
CITY OF CARLSBAD
2075 Las Palmas Dr., Cr1sbad, CA 92009 (619) 4381161
-
-
CITY OF CARLSBAD
* INSPECTION REQUEST
PERMIT# CB950099 - FOR 07/28/95 INSPECTOR AREA TP
DESCRIPTION: WAREHOUSE TO OFFICE 1700 SQ FT PLANCK# CB950099
434 SFTI ALSO - 0CC GRP B22
TYPE: ITI CONSTR. TYPE VN
JOBADDRESS: 2738 LOKER AV WEST -; STE: LOT:
APPLICANT: CARLSBAD CROSSROADS LTD PHONE: 619-431-7233
CONTRACTOR: PHONE:
OWNER: PHONE: ()
REMARKS: MW/JOHN/855-1718 INSPECTOR
SPECIAL INSTRUCT: -
1 I
. --•••
TOTAL TIME: _____ -• * ..
- *
--RELATED PERMITS-- PERMIT# TYPE STATUS
SE950003 SWOW ISSUED . .
A5950043 ASTI ISSUED .
CD LVL DESCRIPTION •. ACT COMMENTS
19, ST Final Structural
29 PL Final Plumbing.
,39 'EL Final-Electrical
49 ME Final Mechanical
I.
***,**-INSPECTION HISTORY.***** -'
DATE DESCRIPTION ACT INSP COMMENTS
071895 Frame/Steel/Bolting/Welding AP TP -' T-BAR GRID
071895 Rough Electric AP TP CEILING LITES -
071895 Rough/Ducts/Dampers . CO TP SEE JOB-CARD -
071495 Frame/Steel/Bolting/Weldiig NR PK NO PLANS/NO JOB CARD/CElL NR
071395 Interior Lath/Drywall AP TP GREEN. BOARD @ RESTRMS
0:70395- Rough/Topout CO TP D.W. •W/O INSP(PLUN WALL)
062995 Interior Lath/Drywall AP. PY
062995 Rough/Topout . • AP -PY ND•ROOF EQUIP ON PLATFORM
,062895 Frame/Steel/Bolting/Welding PA PY WALL/CEILING @ BATHROOM
7 -
-
.- -
I • . • • - :-
4 • . •• . . - • --. •-.
. . . >.
- .
••.
•-
a •
• 1
-
---1 ,•.1
ESGIL CORPORATION
9320 CHESAPEAKE DR., SUITE 208
SAN DIEGO, CA 92123
(619) 560-1468
DATE: MAY, 26, 1995 0 APPLICANT
IJU
JURISDICTION: CARLSBAD 0 PLAN REVIEWER
0 FILE
PLAN CHECK NO.: 95-99
-
SET: III $
PROJECT ADDRESS 2738 LOCKER AVE
PROJECT NAME: T.I.
The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes.
The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff.
j The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
. The check list transmitted herewith is for your information. The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck. •
The applicant's copy of the check list is enclosed for the jurisdiction to forward t&the applicant
contact person. . S
The applicant's copy of the check list has been sent to:
Esgil Corporation staff did not advise theapplicant that the plan check has been completed.
Esgil Corporation staff did advise the applicant that the pincheck has been 'completed:
Person contacted: • • .
Date contacted: (by: ) Telephone #:
REMARKS: Specify two sources of power for exit signs. 0
By: Ali Sadre Enclosures: 0
Esgil Corporation • 5/23 0
GA CM n PC trnsmtl.dot
f,cLZ -a'-
ESGIL CORPORATION
9320 CHESAPEAKE DR., SUITE 208
SAN DIEGO, CA 92123
(619) 560-1468
DATE: MAY 9, 1995
JURISDICTION: CARLSBAD
PLAN CHECK NO.: 95-99
PROJECT ADDRESS: 2738 LOCKER AVE.
PROJECT NAME: T.I.
U AERLICi V
(• 5URISDICTIO'N) V
PtAN-REVFEWR
U FILE
SET: II
The plans transmitted herewith have been corrected where necessary and substantially comply
V with the jurisdiction's building codes.
V The plans transmitted herewith will substantially comply with'the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff.
The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck. V
The check list transmitted herewith is for your information. The p!ans are being held at Esgil
Corporation until corrected plans are submitted for recheck.
The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person. - -
The applicant's copy of the check 'list has been sent to: V
VIRGINIA LANE 2734 LOCKER AVE, W., # M, CB, CA 92008
V
Esgil Corporation staff did not advise the applicant that the plan check has been completed.
J Esgil Corporation staff did advise the applicant that the plan check has been completed.
Person contacted: • V
V Date contacted: (by: ) Telephone #:
REMARKS:
V
By: AL! SADRE V
Esgil Corporation
GA E CM
Enclosures:
PC 5/1 ' trnsmtl.dot
CARLSBAD 95-99 II
MAY 9, 1995
RECHECK PLAN CORRECTION LIST
JURISDICTION: CARLSBAD
PROJECT ADDRESS: 2738 LOCKER AVE.
DATE PLAN RECEIVED BY
ESGIL CORPORATION: 5/1
I REVIEWED BY: ALl SADRE
PLAN CHECK NO.: 95-99
.SET: II
DATE RECHECK COMPLETED:
MAY 9, 1995
I
FOREWORD (PLEASE READ):
This plan review is limited to the technical requirements contained in the Uniform Building Code,
Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws
regulating energy conservation, noise attenuation and disabled access. This plan review is
based on regulations enforced by the Building Department: You may have other corrections
based on laws and ordinances enforced by the Planning Department, Engineering Department
or other departments.
The following items need clarification, modification or change. All items must be satisfied
before the plans will be in conformance with the cited codes and regulations. Per Sec. 303 (c),
1991 Uniform Building Code, the approval of the plans does not permit theviolation of any
state, county or city law.
Please make all corrections on the original tracings and submit two new sets of prints to:
ESGIL CORPORATION.
To facilitate rechecking, please identify, next to each item, the sheet of the plans upon
which each correction on this sheet has been made and return this sheet with the
revised plans.
The following items have not been resolved from the previous plan reviews. The original
correction number has been given for your reference. In case you did not keep a copy of
the prior correction list, we have enclosed those pages containing the outstanding
corrections. Please contact me if you have any questions regarding these items.
- D. Please indicate here if any changes have been made to the plans that are not a result of
corrections from this list. If there are other changes, please briefly describe them and where
they are located on the plans. Have changes been made not resulting from this list?
CARLSBAD 95-99 II
MAY 9, 199S
# 13) Sho artitions -on floor plans with minmum+-6,~ _heig.... dtl~ all
the corridor boundaries. s-s a s are unacceptable. Provide
le ypes with Complete details an re e c
ELECTRICAL PLAN REVIEW
JURISDICTION: Carlsbad DATE:519195
PLAN REVIEW NUMBER: 95-99 II .
PLAN REVIEWER: Chuck Mendenhall
Provide two sources of power or specify self luminous power for the new exit signs.
the revised plans show exit signs bUt do not indicate the second source of power.
Provide a receptacle within 25' of the new HVAC equipment. The plans do not
have a note regarding this requirement.
28 Show on the lighting plan which switch controls which light fixture The switches
must control the lighting in a uniform pattern.
PLUMBING, MECHANICAL AND ENERGY CORRECTIONS
JURISDICTION: Carlsbad DATE:5/9/95
PLAN REVIEW NUMBER: 95-99 SET: II
PLAN REVIEWER: Glen Adamek
31. Detail ladder access to roof mounted HVAC equipment.
32. Detail disposal of main condensate drainage from air conditioning units. (UMC
Section 510)
34. Show water heater size, type, location and access on plans. UPC, Section 1301.
Also detail P & T valve on water heater and detail drain line route from P & T
valve to the exterior. UPC Section 1007(e).
Show 1/4 inch per 12 inch slope on drain and waste lines. UPC Section 407.
New water closets and associated flushometër valves, if any, shall use no more
than 1.6 gallons per flush and shall meet performance standards established by
the American National Standards Institute Standard Al 12.19.2. H & S Code,
Section 17921.3(b). .•
CARLSBAD 95-99 II
MAY 9, 1995
38. The completed and signed ENV-1, and MECH-1 forms must be imprinted on the
plans. .
Note: If you have any questions regarding this plan review list please contact Glen
Adamek at (619) 560-1468. To speed the review process, note on this list (or a
copy) where thecorrected items have been addressed on the plans.
H
MAY 19 '95 14:27 MAGGETTI ELAM ASSC. - P.2/4
I
May 19, 1995
Pat Kelly
City of Carlsbad
RE: Interior Specialist
Plan file # 95.99
This is the project that I spoke to you about on the phone Wednesday. As you can see
by the attached correction from Esgil, they are requesting that the partitions be a
minimum of 5'-9" high. (Please refer to the attached plan for the location of the
partitions). 0 .
As I explained to you, the. tenant, Interior Specialist has purchased partitions which are
65" tall. It seems that to ask them to discard their 65" panels and purchase panels which
are 4" taller is extreme and missing the "spirit of the code".
Per "Exception 5" we are locating a smoke alarm system along the corridor.
Additionally, the partitions will be permanently fixed to the floor.
Dan Suhovecky with Interior Specialists will be contacting you to discuss this. Please
call me if you have any questions. The plan checker at Esgil is Ali Sadie.
Sincerely,
Marianne Elam
Maggetti Earn Associates
cc: Dan Suhovôcky
MAGGETTIELAM A$SOCIA'TES
3160 CAMINO DEL RIO SOUTH SUITE 207 SAN DIEGO0 CA 92108 619.624.0521 FAX 619.624.0530
V
MAY 19 '95 14:28 MAGGETTI ELATI ASSOC...---'
- - ---- .--- -
- -.------S---- - P.3/4
!) BAD 95-99
1995
Show permanent partitions on floor plans with minimum 5'-9' hei
g
h
t
d
e
f
i
n
i
n
g
all
the corridor boundaries. A3shown low partition walls
a
r
e
u
n
a
c
c
e
p
t
a
b
l
e
.
P
r
o
v
i
d
e
a legend for the wall types hete details and references
ELECTRICAL PLAN REVIEW .
. *
JURISDICTION: Carlsbad. DATE:519195
PLAN REVIEW NUMBER: 95.99 II
PLAN REVIEWER. Chuck Mendenhall
9(Provide two sources of power or specify self luminous power for the new ex
i
t
s
i
g
n
s
.
the revised plans show exit Signs but do not indicate the second s
o
u
r
c
e
o
f
p
o
w
e
r
.
Provide a receptacle within 25' of the new HVAC equipment. The pla
n
s
d
o
n
o
t
have a note regarding this requirement. S.'.c -T 1V?..
Show on the lighting plan which switch controls which 'light fixture. The switches
must control the lighting In a uniform pattern
PLUMBING, MECHANICAL AND ENERGY CORRECTIONS
JURISDICTION: Carlsbad . . . DATE: 5/9/95
PLAN REVIEW NUMBER: 95-99 . SET: II .
PLAN REVIEWER: Glcn Admck . ..
Detail ladder access to roof mounted HVAC equipment.
Detail dlspoial of main condensate drainage from air conditioning u
n
i
t
s
.
(
U
M
C
Section 510) .
. Show water heater size, type, location and access on plans. UPC, Section 1301.
Also detail P & T valve on water heater and detail drain line route from P & T
valve to the exterior. UPC Section 1007(e).
Show 1/4 Inch per 12 Inch slope on drain and waste lines. UPC Se
c
t
i
o
n
4
0
7
;
X New water closets and associated flushorneter valves, if any, shalt use no more
than 1.6 gallons per flush and shall meet performance, standards es
t
a
b
l
i
s
h
e
d
b
y
the American National Standards Institute Standard A112.19.'2. H & S Code,
Section 17921.3(b).
/
MAY 19 '95 14:28 MAGGETTI ELAM ASSOC.
LL
Li11 r
AI.
mi ft H
I 111 1 ••' __ ____
10
in h
I \
J NZ 7 14
ESGIL CORPORATION
9320 CHESAPEAKE DR., SUITE 208
SAN DIEGO, CA 92123
(619) 560-1468
DATE: JAN. 24, 1995 El APPLICANT
JURISDICTION: CARLSBAD 0 PLAN REVIEWER
0 FILE.
PLAN CHECK NO.: 95-99 SET: I
PROJECT ADDRESS: 2738 LOCKER AVE.
PROJECT NAME: T.I.
The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes.
The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff.
The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
The check list transmitted herewith is for your information. The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck.
The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
The applicant's copy of the check list has been sent to:
VIRGINIA LANE 2734 LOCKER AVE, W., # M, CB,CA 92008
Esgil Corporation staff did not advise the applicant that the plan check has been completed.
Esgil Corporation staff did advise the applicant that the plan check has been completed.
Person contacted:
Date contacted: (by: ) Telephone #:
REMARKS
By: AL! SADRE Enclosures:
Esgil Corporation
GA E CM PC 1/16 trnsmtl.dot
CARLSBAD 95-99
JAN. 24, 1995
PLAN REVIEW CORRECTION LIST
TENANT IMPROVEMENTS
IPLAN CHECK NO.: 95-99 JURISDICTION: CARLSBAD
IOCCUPANCY: B2 USE: OFFICE
TYPE OF CONSTRUCTION: VN. ACTUAL AREA: 2134
ALLOWABLE FLOOR AREA: NO CHNG STORIES: NO CHNG
HEIGHT: NO CHNG
ISPRINKLERS?: YES
II REMARKS:
DATE PLANS RECEIVED BY
JURISDICTION: 1/12
DATE INITIAL PLAN REVIEW
COMPLETED: JAN. 24, 1995
OCCUPANT LOAD: 95
DATE PLANS RECEIVED BY
ESGIL CORPORATION: 1/16
PLAN REVIEWER: AL! SADRE
FOREWORD (PLEASE READ)
This plan review is limited to the technical requirements contained in the Uniform Building Code,
Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws
regulating energy conservation, noise attenuation and access for the disabled. This plan review
is based on regulations enforced by the Building Department. You may have other corrections
based on laws and ordinances enforced by the Planning Department, Engineering Department,
Fire Department or other departments. Clearance from those departments may be required
prior to the issuance of a building permit
Code sections cited are based on the 1991 UBC
The following items listed need clarification, modification or change. All items must be satisfied
before the plans will be in conformance with the cited codes and regulations. Per Sec. 303 (c),
.1991 Uniform Building Code, the approval of the plans does not permit the violation of any
state, county or city law.
To speed up the recheck process, please note on this list (or a copy) where each
correction item has been addressed, i.e., plan sheet number, specification section. etc.
Be sure to enclose the marked UD list when you submit the revised plans.
LIST NO. 40, TENANT IMPROVEMENTS WITHOUT SPECIFIC ENERGY DATA OR POLICY SUPPLEMENTS (1991 UBC) tiforw.dot
CARLSBAD 95-99
JAN. 24, 1995
Please make all corrections on the original tracings and submit two new sets of
prints, to:
Esgil Corporation, 9320 Chesapeake Drive, Suite #208, San Diego, CA 92123,
(619) 560-1468.
Provide the correct address and suite number of tenant space on the plans.
Section 302(d).
On the first sheet of the plans indicate: the occupant load of the remodel areas
and the floor where the tenant improvement is located.
4. Provide a note on the plans indicating if any hazardous materials will be stored
and/or used within the building which exceed the quantities listed in UBC Tables
9-A and 9-13.
5. A complete description of the activities and processes that will occur in this
tenant space should be provided.
-; 6. Provide a statement on the Title Sheet of the plans that this project shall comply
with Title 24 and 1991 UBC, UMC and UPC and 1990 NEC.
• 7. Indicate the use of all spaces adjacent to the area being remodeled or improved.
8. Show safety glazing in the following locations, per Section 5406(d):
a) Where the nearest edge of glazing is within a 24-inch arc of either side of
a door in a closed position (unless there is an intervening wall between
the door and the glazing or if the glazing is 5'-0" or higher above the
walking surface).
b) Glazing greater than 9 square feet with the bottom edge less than 18"
above the floor and the top edge greater than 36" above the.floor, (unless
the glazing is more than 36" horizontally away from walking surfaces or if
a complying protective bar is installed).
9. Note on the plans: "All interior finishes must comply with Chapter 42 of the UBC"
Specify "Class III flame spread rating (minimum) for 132."
10.. Note on plan that suspended ceilings shall comply with UBC Tables 47-A and
23-P.
11. In buildings having floors and roofs of wood frame construction draft stop the
area between the ceiling and floor above so that no concealed space exceeds
1,000 s.f. and no horizontal dimension exceeds 60 L.F. (if space has sprinklers,
then 3,000 s.f. and 100 L.F.). Section 2516(f).
12. In buildings having floors and roofs of wood frame construction draft stop the
area between the ceiling and roof above so that no concealed space exceeds
CARLSBAD 95-99
JAN. 24, 1995
3,000 s.f. and no horizontal dimension exceeds 60 L.F. (if space has sprinklers,
then 9,000 s.f. and 100 L.F.). Section 2516(f).
13. Rooms with more than 10 occupants may have one exit through one adjoining
room. Revise exits to comply. Section 3303(e). Provive an exiting plan showing
how occupants from each 1000 square feet of floor area exit directly into a
corridor, or go through one adjoining room before exiting into a corridor.
14. Show the locations of existing exits from the building and show the path of travel
from the remodel area to the existing exits.
15. Note on the plans: "All exits are to be openable from inside without the use of a
key or special knowledge". In lieu of the above, in a Group B occupancy, you
may note "Provide a sign on or near the exit doors reading THIS DOOR TO
REMAIN UNLOCKED DURING BUSINESS HOURS". This signage is only
allowed at the main exit. Section 3304(c).
16. When two exits are required, dead end corridors and exit balconies are limited to
20 feet. Section 3305(e). Corridor outside office #4, A-2.
17. If non-rated corridors are used per Section 3305(g), Exc. 5, provide reference
to the corridors on the floor plan, noting:
Corridors are non-rated per Section 3305(g), Exception 5.
Smoke detectors shall be maximum 30' on center.
C) Power supply shall be dedicated branch circuit. Circuit disconnecting
means shall be accessible only to authorized personnel and shall be
clearly marked FIRE ALARM CIRCUIT CONTROL, with a lock-on device.
18. Clearly show where the non-rated corridor system per item 17 starts and where it
terminates on A-2.
. ELECTRICAL
19. Submit plan showing location of all panels.
20. Submit panels schedules.
21. Submit electrical load calculations.
22. Indicate existing main service size.
23. Indicate existing total main service load.
24. Indicate new additional loads.
25. Indicate wiring method, i.e. EMT, metal flex.
CARLSBAD 95-99
JAN. 24, 1995
Show exit signs on the electrical lighting plan(s). As per Section 3313 and 3314
of the 1991 UBC, provide two sources of power to exit signs and exit illumination.
Provide receptacle(s) within 25' of HVAC units. UMC Section 509.
Provide multiple switch lighting controls per Title 24, Part 6.
. MECHANICAL
29.'Provide mechanical ventilation in all rooms capable of supplying a minimum of 5
cubic feet per minute of outside air with a total circulation of not less than 15
cubic feet per minute per occupant. Section 605 and 705, UBC.
Provide mechanical plans showing existing and proposed HVAC equipment,
ducts and access to equipment.
Detail access and working clearances to HVAC equipment.
Detail disposal of main condensate drainage from air conditioning units. (UMC
Section 510)
Detail overflow (secondary) condensate discharge from air conditioning units that
are in a ceiling space. (UMC Section 1205)
Show P & T valve on water heater and detail drain line route from P & T valve to
the exterior. UPC Section 1007(e).
Show 1/4" per 12" slope on drain and waste lines. UPC Section 407.
Note on the plans that new water closets and associated flushometer valves, if
any, shall use no more than 1.6 gallons per flush and shall meet performance
standards established by the American National Standards Institute Standard
A112.19.2, and urinals and associated flushometer valves, if any, shall use no
more than one gallon per flush and shall meet performance standards
established by the American National Standards Institute Standard Al 12.19.2. H
& S Code, Section 17921.3(b).
. ENERGY
Provide complete energy design calculations, including all existing design and
new energy design for this building. See attached nonresidential energy design
reviewlist.
For remodels in an existing conditioned space, show that the remodeled space
will not use more energy than the existing space or show the remodeled space
will conform to latest energy design standards.
CARLSBAD 95-99
JAN. 24, 1995
Roof mounted equipment must be screened and roof penetrations should be
minimized (City Policy 80-6).
No wiring is permitted on the roof of a building and wiring on the exterior of a
building requires approval by the Building Official. (City Policy)
All roof-mounted equipment shall be concealed from view. Provide structural
detailing for the screening.
MISCELLANEOUS
See attached for HC items.
To speed up the review process, note on this list (or a copy) where each
correction item has been addressed, i.e., plan sheet, note or detail number,
calculation page, etc.
Please indicate here if any changes have been made to the plans that are not a
result of corrections from this list. If there are other changes, please briefly
describe them and where they are located in the plans.
Have changes been made to the plans not resulting from this correction list? Please
indicate:
Yes 13 No 13
45. The jurisdiction has contracted with Esgil Corporation located at 9320
Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of
619/560-1468, to perform the plan review for your project. If you have any
questions regarding these plan review items, please contact AL! SADRE at
Esgil Corporation. Thank you.
DEPARTMENT OF STATE ARCHITECTURE-NON RESIDENTIAL
TITLE 24 DISABLED ACCESS REQUIREMENTS
SCOPE: Specify on plans all the existing site items are HC complying. field verify.'Also imprint notes
below on plans.
DOORS
Per section 3304(i.1),regardless of the occupant load, there shall be a level floor or landing on each
side of the door. The floor or landing shall not be more than '2 lower than the threshold of the
doorway. Note: An exception is permitted for exterior landings, which may slope up to 1/4I per foot
(2%) in any direction, for surface drainage, per section 413.
Per section 3304(c.1), all hand-activated door opening hardware shall meet the following
requirements:
a) Shall be centered between 30" and 44" above the floor.
CARLSBAD 95-99
JAN. 24, 1995
b) Latching and locking doors that are in a path of travel shall be operated with a single effort
by lever type hardware, panic bars, push-pull activating bars or other hardware designed to
provide passage without the ability to grasp the opening hardware.
C) Locked doors shall exit in the direction of travel.
The lower 10" of all doors shall be smooth and uninterrupted to allow the door to be opened by a
wheelchair footrest without creating a trap or hazardous condition. Narrow frame doors may use a
10" high smooth panel on the push side of the door.
The width of the level area, on the side to which a door (or gate) swings, shall be as follows per
section 3304(i.1):
a) *Extend 12" past the strike edge on the push side if door has latch and closer. Office 4 and
9.
Maximum effort to operate doors shall not exceed 81/2 pounds for exterior doors and 5 pounds for
interior doors. Such push or pull effort shall be applied at right angles to hinged doors and at the
center plane for sliding doors. Where fire doors are required, the maximum effort to operate the door
may be increased to 15 pounds. See section 3304(i.2)1.
. SANITARY FACILITIES
Doorways leading to men's sanitary facilities shall be identified by an equilateral triangle 1/4"thick
with edges 12" long and a vortex pointing upward. Women's facilities shall be identified by a circle,
1/4" /4 thick, 12" in diameter. Unisex facilities shall be identified by a circle with a triangle superimposed
on the circle and within the 12" diameter. The required symbols shall be centerei on the door at
a height of 60". *See section 3105A(b)1.D. See 3105A(e)10 for additional signage.
. RESTROOM FIXTURES AND ACCESSORIES
Water closets in accessible restrooms shall meet the following requirements per section 5-1502:
The height of the water closet seat shall be between 17" and 19".
The controls shall be operable with one hand and shall not require tight grasping, pinching or
twisting of the wrist.
C) The controls for flush valves shall be mounted on the side of the toilet area and be no more
than 44" above the floor.
d) The force required to activate the controls shall be no greater than 5 pounds of force.
Lavatories shall comply with the following requirements per section 3105A(b)4.A., 3105A(h)4. and 5-
1504:
A minimum of 30" x 48" clear space shall be provided in front of the lavatory for forward
approach. The clear space may include knee and toe space beneath the fixture.
The clear space beneath lavatories shall be a minimum of 29" high x 30" wide x 8" deep at
the top and 9" high x 30" wide and 17" deep at the bottom from the front of the fixture. The
maximum height of the counter top shall be 34"
C) All hot water and drain pipes under the lavatory shall be insulated.
The faucet controls and operating mechanism shall be of the type not requiring tight
grasping, pinching or twisting of the wrist and have an operating force of not greater than 5
pounds.
If self-closing valves are used, they shall remain open for at least 10 seconds.
9. Grab bars shall comply with the following per section 3105A(b)3.C.:
The diameter or width of the grab bar gripping surface shall be 11/4I to 11/2 or the shape
shall provide an equivalent gripping surface. If mounted adjacent to a wall, the space
between the wall and the grab bar shall be 11/2 .
See section 3105A(b)3.C.(iii) for structural strength requirements.
CARLSBAD 95-99
JAN. 24, 1995
10. *Per section 3105A(b) and (c), where lockers are provided for the public, clients, employees,
members or participants, at least one and not less than 1% of all lockers shall be made accessible to
the physically disabled. A path of travel of not less than 36 in clear width shall be provided to those
lockers.
CARLSBAD 95-99
JAN. 24, 1995
VALUATION AND PLAN CHECK FEE
JURISDICTION: CARLSBAD PLAN CHECK NO.:. 95-99
PREPARED BY: AL! SADRE DATE: JAN. 24, 1995
BUILDING ADDRESS: 2738 LOCKER AVE. BUILDING OCCUPANCY: B2
. TYPE OF CONSTRUCTION: VN
BUILDING PORTION BUILDING AREA VALUATION VALUE
(sq. ft.) MULTIPLIER ($)
T.I. 12134 126 155484
Air Conditioning
Fire Sprinklers
TOTAL VALUE 55484
Building Permit Fee: . . $ 441.50
Plan Check Fee: . . $ 286.98
Comments: .. -
Sheet of I
. valuefee.dot
...
City. of --Carlsbad
E-Engineering Department
i// BUILDING PLANCHECK CHECKLIST V .
V DATE//fl/f PLANCHECK NO.CB
V V BUILDING' ADDRESS: , zP
PROJECT DESCRIPTION: /'j 77 C,i -,dtEr l7ao f V V
ASSESSOR's PARCEL NUMBER: V EST. VALUE K V V V
ENGINEERING DEPARTMENT
p
- DENIAL
V APPROVAL Please see the attached report of deficiencies marked
The item you have submitted for review has been with 0 Make necessary corrections to plans or
approved. The approval is based on plans, information specifications for compliance with applicable codes and
V and/or specifications provided In your submittal; therefore standards. Submit corrected plans and/or specifications
any changes to these items after this date, Including field • to this office for review. V
•V V V
V V modifications, must be reviewed by this office to insure •.
V V •. V
continued conformance with applicable codes. Please
V
V
V.V V
VVVV
V
V V review carefully all comments attached, as failure to
V comply with instructions in this report can result In' By: V Date: V•• •
suspension of permit to build
El A Right-of-Way permit is required prior to construction By Date
of the following improvements
By Date
- - _ V • •.
V• _VVV;. V
V-V .. V •V- •V •
V V VV V_ V . V . V . . •V V
V V
• • V•4 V V VV• •VV V
V(VVV •V .V fV V V .••. V V
V V V V V V V VV . V
V .VV V I V • V V V
• VV V V -
. V •
ATTACHMENTS ENGINEERING DEPT CONTACT PERSON
El Dedication Application
El Dedication Checklist
El Improvement Application
0 Improvement Checklist NAME
El Future improvement Agreement - City of Carlsbad
0 Grading Permit Application ADDRESS 2075 Las Palmas Dr Carlsbad CA 92009
El Grading Submittal Checklist PHONE (619) 438-1161 Ext.
El Right of Way Permit Application
0 Right of Way Permit Submittal Checklist
and Information Sheet
- El Sewer Fee Information Sheet ' A-4
P:\D0CS\CHKLST\8P0001.FRM REV 05/11/94
2075 Las Palmas Dr. • Carlsbad CA 92009-1576 • (619) 438-1161 • FAX (619)438-o894
BUILDING PLANCHECK CHECKLIST
SITE PLAN
/s
2,
nd,/ 3rd,/
0 1. Provide a fully dimensioned site plan drawn to scale. Show:.. S.
North Arrow D. Property Lines Easements .
/ Existing & Proposed Structures E. Easements
• Existing Street Improvements F. Right-of-Way Width & Adjacent Streets
0 0 2. Show on site plan:
/ Drainage Patterns . C. Existing Topography
Existing & Proposed Slopes
j 0 0 3. Include note: "Surface water to be directed away from the building foundation at a 2%
I 14 gradient for no less than 5' or 2/3 the distance to the property line (whichever is less)."
[Per .1985 UBC 2907(d)5]. • . .
• On graded sites, the top of any exterior foundation shall extend above the elevation•
of the Street gutter at point of discharge or the inlet of an approved drainage device
/ . a minimum of 12 inches plus two percent" (per 1990 UBC 2907(d)5.).
L?i 0 0 4. Include on title sheet . S
• Site address • S • *
Assessor's Parcel Number .. . • .
Legal Description •
For commercial/industrial buildings and tenant improvement projects, include: Total
S building square footage with the square footage for each different use, existing sewer
permits showing square footage of different uses (manufacturing, warehouse, office,.
S
•
etc.) previously approved. S S • •
• S • EXISTING PERMIT NUMBER DESCRIPTION
S
i- q, siicii p,ip / 'gç - • 2. 9ff1
/97c)
5qst i 3l54ç- 77) ,'tik lzu/kc
fi f5ñ3
S P:\D0CS\CHKLS1\BP0001.FRM S Page 1 Of 4 • • S • REV 05/11/94
c1•
BUILDING PLANCHECK CHECKLIST
DISCRETIONARY APPROVAL COMPLIANCE
1 sfr 2nd../ 3rdv'
44 0 0 5. Project does not comply with the following Engineering Conditions of approval for
Project No.
Conditions were complied with by: Date:__________________
A
DEDICATION REQUIREMENTS
0 0 6. Dedication for all Street Rights-of-Way adjacent to the building site and any storm
/ drain or utility easements on the building site is required for all new buildings and for
remodels with a value at or exceeding $_____________ -pursuant to Code Section
18.40.030.
Dedication required as follows: ,
00
(1
Attached please find an application form and submittal checklist for the dedication
process. Provide the completed application form and the 'requirements on the
checklist at the time of resubmittal.
Dedication completed by • Date:___________
IMPROVEMENT REQUIREMENTS
7a. All needed public improvements upon and adjacent to the building site must- be
constructed at time of building construction whenever the value of the construction
exceeds $ S -pursuant to Code Section 18.40.040.
Public improvements required as follows:
Please have a registered Civil Engineer prepare appropriate improvement plans and
submit them together with the requirements on the attached checklist for-a separate
plancheck process through the Engineering Department. Improvement plans must be
approved, appropriate securities posted and fees paid prior to issuance of permit.
Attached please' find an application form and submittal checklist for the public
improvements requirements. Provide the completed application form and the
requirements on the checklist at the time of resubmittal. .
Improvement Plans signed by:
,
S ' Date:
P:\DOCS\CHKLS1N9P0001.FRM , Page 2 of 4
REV 05/11/94
BUILDING PLANCHECK CHECKLIST
1 SW 2nd,/ 3rd/
O 0 0 7b. Construction of the public improvements may be deferred pursuant to code Section
18.
-
40. Please submit a recent property title report or current grant deed on the
prperty and processing fee of $_ so we may prepare the
necessary Future Improvement Agreement. This agreement must be signed, notarized
and approved by the City prior to issuance of a Building Permit..
Future public improvements required as follows:_______________________________
Improvement Plans signed by: Date:___________
0 0 0 7c. Enclosed please find your Future Improvement Agreement. Please return signed and
notarized Agreement to the Engineering Department.
Future Improvement Agreement completed by:
Date:________________
J' 0 0 7d. No Public Improvements required. SPECIAL NOTE: Damaged or defective
improvements found adiacent to building site must be repaired to the satisfaction of
the City Inspector prior to occuøancv.
GRADING PERMIT REQUIREMENTS '
The conditions that invoke the need for a grading permit are found in Section 11.06.030
of the Municipal Code.
0 0 0 8a. Inadequate information available on Site Plan to make a determination on grading
requirements. Include accurate grading quantities (cut, fill import, export).
8b. Grading Permit required. A separate grading plan prepared by a registered Civil
Engineer must 'be Submitted together with the completed application form attached.
NOTE: The GradinctPermit must be issued and rouah aradina aaoroval obtained oriOr
to issuance of a Building Permit. '
Grading Inspector sign off by:' Date:
8c. No Grading Permit required. '
(
P:\DOCS\CHKLST\BP0001.FRM Page 3 of 4
-
(I
BUILDING PLANCHECK CHECKLIST ,
MISCELLANEOUS PERMITS
2nd./ 3rdv'
0 0 9. A RIGHT-OF-WAY PERMIT is required to do work in City Right-of-Way and/or
private work adjacent to the public Right-of-Way. Types of work include, but are not
0 limited to: Street improvements, trees, driveways, tieing into public storm drain, sewer
and water utilities
Right-of-Way permit required for
A separate Right-of-Way permit issued by the Engineering Department is required for
the following:
0 .0 10. A SEWER PERMIT is required concurrent with the building permit issuance. The fee
/ ) . is noted in the fees section on the following page.
!t1Y 0 0 ii. INDUSTRIAL WASTE PERMIT is required. Applicant must complete Industrial
Waste Permit Application Form and submit for City approval prior to issuance of a
Permit.
Industrial waste permit accepted by: Date:
P:\DOCS\CHKLS1\BP000I.FRM Page 4 of 4 . REV 05/11/94 ..
ENGINEERING DEPARTMENT ENGINEERING REVIEW SECTION
FEE CALCULATION WORKSHEET
o Estimate based on unconfirmed information from applicant.
Calculation based on building plancheck plan submittal.
Address: ,Z 7,:3,eok i9v' ) Bldg. PermIt. No.______________
Prepared by: Date: Checked by: Date_________________
EDU CALCULATIONS: List types and square footages for all uses.
Types of Use: Sq. Ft.:/ 7ô i -' /F'DD EDU's: •
€e4fr ''/cE /
Total EDU's:________________
ADT CALCULATIONS: List types and square footages for all uses.
Types of Use: 9 f4 C_. Sq. Ft.:_/7pIOOoX4eADTs:__________________
eebrh't . /7oa/o40C - 9.
Total ADTs:2
FEESREQUIRED:
PUBLIC FACILITIES FEE REQUIRED 0 YES
x
NO (See B,9jng Department for amount)
WITHIN CFD: DYES (no bridge & thoroughfare fee, )4N0
/ reduced Traffic Impact Fee) .
.PARK.IN-UEU FEE PARK AREA:________
FEE/UNIT: X NO. UNITS: $___________
)2.TRAFF1C IMPACT FEE
ADrs: X FEE/ADT:
BRIDGE AND THOROUGHFARE FEE
ADrs: X FEE/ADT:_______ $ /f
FACILITIES MANAGEMENT FEE ZONE:________
1" SQ.FT.: X FEE/SOFT.: =$___________
)(5. SEWER FEE
PERMIT No6'
EDU's: - X FEE/EDU: /I' =__________
BENEFIT AREA: - DRAINAGE BASIN:
EDU's: X FEE/EDU:7t =s_____________
6. SEWER LATERAL ($2,500 DEPOSIT)
WATER FEE .
EDU's: ' X FEE/EDU:_______
TOTAL OF ABOVE FEES *:$
*NOTE: This calculitlon sheet Is NOT a complete list of all fee. which may b. due.
Dedications and Improvements may also be required with Building Permits.
P:\D0CS\MlSF0RMS5P0002.FRM REV 04/12/94
2
PLANNING Q{EOQLSr
Plan check No. Address 273k L-ôker A- Li
Planner DAVID RICK ___•Phone 438-1161 ext. 4328
(Name)
APN:
Type of Project and Use
Zone —fM Facilities Management Zone
(D ut) #_______________
circle (If property in, complete SPECIAL TAX CALCULATION
WORKSHEET provided by Building Department.)
[tern Complete
[tern Incomplete - Needs your action
1, 2, 3 Number in circle indicates plancheck number where deficiency was
identified
0 Environmental Review Required: YES - NO 'YPE
DATE OF COMPLETION:
Compliance. with conditions of approval? If not, state, conditions which require action.
Conditions of Approval
Discretionary Action Required: YES - NO - TYPE
APPROVAL/RESO. NO. DATE:
PROJECT NO.
OTHER RELATED CASES:
Compliance with conditions of approval? If not, state conditions which require action.
Conditions of Approval
California Coal Coon Pit Re YES - NOZ
DATE OF APPROVAL:
San Diego Coast District, 3111 Camino Del Rio North, Suite 200, San Diego, CA. 92108-1725
(619) 521-8036 . .
Compliance with conditions of approval? If not, state conditions which require action.
Conditions of Approval
1. Setbacks:
Front:
Int. Side:
Street Side:
Rear:
Lot coverage:
Height: -
Parking:
Required
Spaces Required
Guest Spaces Required
Shown
Lg3q Shown LJ73
Shown
Required Shown
Required Shown
Required . Shown
Required Shown
Required Shown
Inclusionary Housing Fee required: YES ___ NO _< (Effective date of Inclusiortaiy Housing Ordinance - May 21, 1993.)
Site Plan
0 Provide a fully dimensioned site plandrawn to scale. Show: North
arrow, property lines, easements, existing and proposed structures,
streets, existing street improvements, right-of-way width, dimensioned
setbacks and existing topographical lines.
Provide legal description of property, and assessor's parcel number.
O 0 0 Additional Comments . .
. .
01< TO ISSUE AND ENTERED APPROVAL INTO COMPUTER DATE
1/.
PLNCK.FRM
r
City of Carlsbad 95010
Fire Department • Bureau of Prevention
Plan Review: Requirements Category: Building Plan Check
Date of Report:Thursday, February 16, 1995 Reviewed by: (7. &c1—
Contact Name Mageti-Elam Assoc
Address 3160 Camino Del Rio Ste 20
City, State San Diego CA 92108
LldDetNo. 95-99 Planning No.
Job Name Interior Specialists
Job Address 2738 Loker
S
Ste. or Bldg. No.
t
Approved - The item you have submitted for review has been approved. The approval is
based on plans; information and/or specifications provided in your submittal;
therefore any changes to these items after this date, including field modifica-
tions, must be reviewed by this office to insure continued conformance with
applicable codes. Please review carefully all comments attached, as failure'
to comply with instructions in this report can result in suspension of permit to
construct or install improvements.
O Disapproved - Please see the attached report of deficiencies. Please make corrections to
plans or specifications necessary to indicate compliance with applicable
codes and standards. Submit corrected plans and/or specifications to this
office for review.