HomeMy WebLinkAbout2741 MONROE ST; ; CB900432; PermitFA
BUILDING PERMIT
05/30/90 12:11
Page 1 of 1'
Job Address: 2741 MONROE ST Str:
Permit Type: RESIDENTAL ADDITION/ALTERATION
Parcel No: 156-340-06-00..
Valuation: 31,361
Construction Type: NEW
Occupancy Group: Class Code:
Description: CONVERT BASEMENT TO LIVING ARE
A 615 SF
Permit No: CB900432
Project No: A9000528
Development No:
Fl: Ste:
5B02 -05/30/90 0001 01 02
CPRMT 371.00
Status: ISSUED
Applied : 03/16/90
Apr/Issue : 05/30/90
Validated By: DC
'OWNER : BOSHARD, STEVEN Lic..
Fees Required *** Fees Collected & Credits
Fees: 569.,00 (7 (\ j "N Adjustments: /oo,-- TgtallCredits: .00
Total Fees: 569.00,,CJ) Tot]JP'a'yment: 198.00
1 . BalanceDue:\ 371.00 / 1\ \ \ Fee description' / '\\ / .I-7 Units- \ Fee/Unit Ext fee Data
-:'- I; "i/'i . \ ( p-" \
Building Permit / 298.00
Plan Check 194.00
Strong Motion Fee 2.00
BUILDING TOTAL UJ 494.00
Enter "Y" for Plumbing Issue Fee-1> 7.50 Y
Each Plumbing Fixt~re or Tr~p ~> . 3.00 2.50 50
Each Building Sewer, \'\ 1.00 7 6.50/ 6.50
* PLUMBING TOTAL \ 22.00
Enter "Y" for Electric Issue Fee/ > \S'-i / / 5.00 Y
Other \ f'62 10 .00 j-, / 10.00 REMODEL
* ELECTRICAL TOTAL ($10 MinirnUm) S\\j' / 15.00
Enter 'Y' for Mechanical Iss/Fee> / 15.00 Y
Install Furn/Ducts >r1.1 \ 1 0.0 / 9.00 9.00
Each Install/Reloc Appliance Vent > '3.00-' 4.50 ., 13.50
* MECHANICAL TOTAL . .' 38.00
APPROVAL
-DATEZ'/
INS NR L 2.
CLEARANCE
- CITY OF CARLSBAD
2075 Las Palmas Dr., Carlsbad CA 92009 (619) 438.1161
PERMIT APPLICATION
City of Carlsbad Building Department
2075 Las Palmas Dr., Carlsbad, CA 92009 (619) 438-1161
1. PERMIT TYPE I
A - 0 COMMERCIAL DNEW DTENANT IMPROVEMENT
B - 0 INDUSTRIAL DNEW OTENANT IMPROVEMENT
C DAPARTMENT DCONDO 1116SINGLE FAMILY DWELLING DADDITION/ALTERATION
ODUPLEX DoEMoLITIoN DRELOCATION DMOBILE HOME DELECTRICAL OPLUMBING
DMECHANICAL DPOOL DSPA DRETAINING WALL OSOLAR DOTHER
IEST.VAI. (,, C:(::) I I PLAN CX DEPOSIT 19 9 I
I VALID. BY C_ - I
DATE
4069 03/16/9 0001 01 02
C-PRjT 178.00
Address frVIo&,re_ suitaing or suite NO
Nearest Cross Streets
LEGAL DESCRIPTION Lot No. Subdivision Name/Number Unit No. Phase No.
CHECK BELOW IF 9JBMITTED: -
fl2 Energy C D2 Structural Calcs 112 Soils Report Lii Addressed Envelope
ASSESSOR'S PARCEL 444". .94/ 'O EXISTING USE PROPOSED USE
ucxt.IslrII,Jn ur Wa,,.
Co KN p L't0 I,
BLDG. 50. FTG. /.4 # OF STORIES
CONTACT PERSON
NAME ADDRESS
CITY STATE ZIP CODE DAY TELEPHONE
SIGNATURE
APPLICANT
NAME jre u e-, j1
CONTRACTOR [-]AGENT FOR CONTRACTOR DOWNER 0 AGENT FOR OWNER
ADDRESS
CITY '3LCAf..?sr.Ilo'- ','S/k STATE ZIP CODE DAY TELEPHONE
PROPERTY OWNER OWNER DLESSEE DTENANT
NAME IeL ADDRESS
CITY STATE ZIP CODE DAY TELEPHONE
CONTRACTOR
NAME ADDRESS
CITY STATE ZIP CODE DAY TELEPHONE
STATE LIC. # LICENSE CLASS CITY BUSINESS LIC. H
SIGNATURE TITLE DATE
DESIGNER NAME ADDRESS
CITY STATE ZIP CODE DAY TELEPHONE STATE LIC. H
WORKERS' COMPENSATION
Workers' Compensation Declaration: I hereby affirm that I have a certificate of consent to self-insure issued by the Director of Industrial Relations,
or a certificate of Workers' Compensation Insurance by an admitted insurer, or an exact copy or duplicate thereof certified by the Director of the
insurer thereof filed with the Building Inspection Department (Section 3800. Lab. C).
INSURANCE COMPANY POLICY NO. EXPIRATION DATE
Certificate of Exemption: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner
so as to become subject to the Workers' Compensation Laws of California.
SIGNATURE ai. /,c,cL4..J DATE 3! /& / 10
OWNER-BUILDER DECLARATION /
Owner-Builder Declaration: I hereby affirm that I am exempt from the Contractor's License Law for the following reason:
as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale
(Sec. 7044, Business and Professions Cede: The Contractor's License Law does not apply to an owner of property who builds or improves thereon., and who
does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building
or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose
of sale.).
0 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7064, Business and Professions Code:
The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s)
licensed pursuant to the Contractor's License Law).
0 I am exempt under Section Business and Professions Cede for this reason:
(Sec. 7031.5 Business and Professions Cede: Any City or County which requires a permit to construct, alter, improve, demolish, or repair any structure,
prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the
Contractor's License Law (Chapter 9, commencing with Section 7000 of Division 3 of the Business and Professions Cede) or that he is except therefrom,
and the basis for the alleged exception. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not
more than five hundred dollars (5500)).
SIGNATURE DATE
COMPLETE THIS SECTION FOR NON-RESIDENTIAL BUILDING PERMITS ONLY:
Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention
program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act?
DYES DNO
Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district?
DYES []NO
Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? -
DYES ONO
IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCD.WANCY NAY NOT BE ISSUED AFTER JULY 1, 1989 UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS
OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION cONTROl. DISTRICT.
CONSTRUCTION LENDING AGENCY
I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec 30970) Civil Cede).
LENDER'S NAME LENDER'S ADDRESS
APPLICANT'S SIGNATURE I certify that I have read the application and state that the above information is correct. I agree to comply with all City ordinances and State laws relating
to building construction. I hereby authorize representatives of the City of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO
AGREE TO SAVE INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES. JIX)OlIENTS, COSTS AND EXPENSES WHICH KAY IN ANY WAY ACCRUE AGAINST SAID
CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT.
Expiration. Every permit issued by the Building Official under the provisions of this Cede shall expire by limitation and become null and void if the building
or work authorized by such permit is not commenced within 180 days from the date of such permit or if the building or work authorized by such permit is suspended
or abandoned at any time after the work is commenced for a period of 180 days (Section 303(d) Uniform Building Cede).
JPLI50TS SIGNATURE DOWNER DCONTRACTOR 0 B PHONE APPROVED BY:
I DATE:
WHITE: File YELLOW: Applicant PINK: Finance
CITY OF CARLSBAD
INSPECTION REQUEST
PERMIT# CB900432 FOR 01/31/91
DESCRIPTION: CONVERT BASEMENT TO LIVING ARE
A 615 SF
TYPE: RAD
JOB ADDRESS: 2741 MONROE ST
APPLICANT: BOSHARD, STEVEN PHONE:
CONTRACTOR:
OWNER: BOSHARD, STEVEN
REMARKS: MH/STEVE/598-9452
SPECIAL INSTRUCT:
INSPECTOR AREA PD
PLANCK# CB900432
0CC GRP
CONSTR. TYPE NEW
STR: FL: STE:
619 598-9452
PHONE:
PHONE:
INSPECTO
TOTAL TIME:
CD LVL DESCRIPTION ACT COMMENTS
19 ST Final Structural
29 PL Final Plumbing
39 EL Final Electrical
49 ME Final Mechanical
***** INSPECTION HISTORY *****
DATE DESCRIPTION ACT INSP COMMENTS
121990 Gas/Test/Repairs AP PD
121990 Gas/Test/Repairs AP PD
112190 Frame/Steel/Bolting/welding CO PD
070390 Rough Combo CO PD
/
ESGIL CORPORATION
9320 CHESAPEAKE DR., SUITE 208
SAN DIEGO, CA 92123
(619) 560-1468
DATE: )flf' JY, /9O OAP LICANT
RISDICT
JURISDICTION: ci/TY OF agap PLAN C
___
[]FILE COPY
PLAN CHECK NO: SET: DUPS
ODES IGNER
PROJECT ADDRESS: R7yl 71ijtJj' 157
PROJECT NAME: 5,jpp.p UiePi.00iZ._?2lJUEE4,Di)
E] The plans transmitted herewith have been corrected where
necessary and substantially comply with the jurisdiction's
building codes.
•The plans transmitted herewith will substantially comply
with the jurisdiction's building codes when minor deficien-
cies identified Air"d are resolved and
checked by building department staff.
E
The plans transmitted herewith have significant, deficiencies
identified on the enclosed check list and should be corrected
and resubmitted for a complete recheck.
ED The check list transmitted herewith is for your information.
The plans are being held at Esgil Corp. until corrected
plans are submitted for recheck.
The applicant's copy of the check list is enclosed for the
jurisdiction to return to the applicant contact person.
The applicant's copy of the check list has been sent to:
Esgil staff didnot advise the applicant contact person that
plan check has been completed.
EJ Esgil staff did advise applicant that the plan check has
been completed. Person contacted:______________
Date contacted: Telephone #
Enclosures:L)OL)L
ESGIL CORPORATION
0 GA 0 AA 0 vw 0DM
ESGIL CORPORATION
9320 CHESAPEAKE DR., SUITE 208
SAN DIEGO, CA 92123
(619)560-1468
DATE:
JUR _IS DICT JURISDICTION: t4 1'
OFILE COPY PLAN CHECK NO: 9OV3- SET:77' cups
ODESIGNER PROJECT ADDRESS: 7ij
PROJECT NAME: jp
E The plans transmitte'd herewith have been corrected where
necessary and substantially comply with the jurisdiction's
building codes.
D The plans transmitted herewith will substantially comply
with the jurisdiction's-building codes when minor deficien-
cies identified are resolved and checked by building department staff.
Ei The plans transmitted herewith have significant deficiencies
identified on the enclosed check list and should be corrected
and resubmitted for a complete recheck.
The check list transmitted herewith is for your information.
The plans are being held at Esgil Corp. until corrected
plans are submitted for recheck.
The applicant's copy of the check list is enclosed for the
jurisdiction to return to the applicant contact person.
The applicant's copy of the check list has been sent to:
Tgu /orri•... cZPP:. p ))
l)iSiiPR b RV
j Esgil staff did -not advise the applicant contact person that
plan check has been completed.!
0 Esgil staff did advise applicant that the plan check has
been completed. Person contacted:_____________________
Date contacted: Telephone #
0 REMARKS:
Enclosures: 416.ii3T ESGIL CORPORATION
0 GA 0 AA 0 vw 0-DM,
JURISDICTION: (-ELjQt Date plans received by plan checker:_______________
PLAN CHECK NO.: '7O/3..._•Date plan recheck completed: '/?390_By:f._W&2 7W
PROJECT ADDRESS: ?'7 Lj1 (Y1DPJ £1 7
TO:
RECHECKPLANCORRECTIONSHEET
FOREWORD:PLEASEREAD
Plan check is limited.to technical requirements contained in the Uniform Building Code, Uniform
Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy
conservation, noise attenuation and disabled access. The plan check is based on regulations enforced
by the Building Inspection Department. You may have other corrections based on laws and ordinances
enforced by the Planning Department, Engineering Department or other departments.
The items shown below need clarification, modification or change. All items have to be satisfied
before the plans will be in conformance with the cited codes and regulations. Per.Sec. 303(c), of
the Uniform Building Code, the approval of the plans does not permit the violation of any state,
county or city law.
A. PLANS
Please make all corrections on the original
tracings and submit two new sets of prints,
and any original plan sets that may have been
returned to you by the jurisdiction, to: ES,Ci/L. 01Z. LDjT)EPi
To facilitate rechecking, please identify,
next to each item, the sheet of the plans
upon which each correction on this sheet has
been made and return this check sheet with
the revised plans.
The following items have not been resolved
from previous plan reviews. The original
correction number has been given for your
reference. In case you did not keep a copy
of the prior correction list, we have
enclosed those pages containing the still
outstanding corrections. Please contact me
if you have any questions regarding these
items.
Please indicate here if any changes have
been made to the plans that are not a result
of corrections from this list. If there are
other changes, please briefly describe them
and where they are located on the plans.
Have changes been made to the plans not
resulting from this correction list? Please
check.
__Yes No
I). P-F14 APPt-c i, M )$ .57ZY
Zo 1 5k Lj cnoA'E ,,j e-x,sr', OJEzL//i.
Pat t1i DI _£tP2I idA_PrQL 197 _11p 6 P7JPiiL _/ paom,
1. SFThJ ii'i-u,J Oa fAiJ pr
V. Pezutor ri '0. py 'CI r,aP/L'( / ii r-7" Air Dc ulo,
5. eVor ( Ri,ki?-.s, o P1 Ad,
_jJ4) l -.. Pri-,J Prr t). H.
¶?D2.ALL DOt2 _rw-,J_-i2/, _iô/,c
D0rF1'6i AL or-S/7 Pii.x
9S7. 540Ld LzeAvW ô /uJDbZPtooLAze--as
? 1zJrs
/O 7. 5/lou) hi i id. Y? "L AR
/ r. .t) /Jb1 Tm r1J PLp,i.
6I i or 1wi.s c) Poi).
)ç. FYil1L'? ROOM .. this,.
orm No. RPCS.41290
PLANS
Please make all corrections on the original
tracings and submit two new sets of prints, and
any original plan sets that may have been
returned to you by the jurisdiction, to:
Esgil Corporation, 9320 Chesapeake Drive,
Suite #208, San Diego, California 92123,
(619) 560-1468.
Please make all corrections on the original
tracings and submit two new sets of prints,
and any original plan sets that may have been
returned to you by the jurisdiction, to:
The jurisdiction's building department.
Indicate on th& Title Sheet of the plans, the name of the legal owner and name of person
responsible for the preparation of the plans. Section 302(a)7.
All sheets of plans must be signed by the
S
e
person responsible for their preparation.
(California Business and Professions Code).
1'•
0 Specify on the Title Sheet of the plans the
gross floor area of each element of this
project including dwelling, garage, carport,
patio, deck and balcony. Section 302(d).
Provide a statement on the Title Sheet of the
plans that this project shall comply with Title
24 and 1988 UBC, UMC and UPC and 1987 NEC.
Submit fully dimensioned plot plan drawn to
scale showing location, size, and use of all
existing and proposed structures on the lot.
Identify property lines and show lot dimensions
and all easements. Show location of all cut or
fill slopes. Show finish floor elevations and
show elevations of adjacent *finish grade.
Show drainage patterns with minimum slopes.
Section 302(d).
9. Indicate distance from property lines to
proposed building. Section 302(d).
310. Show on the title sheet all structures, pools,
walls, etc. included under this application.
Any portion of the project shown on the site
plan that is not included with the building
permit application filed should be clearly
identified as "not included."
11: Clearly show if the lower level is a basement
or a story, based on the definitions in
Sections 403 and 420. Plot the finish grade
(as defined) on the elevations and dimension
- the distance to the floor above, for story
U12.On the cover sheet of the plans, specify any
items requiring special inspection, by way of
the following:
REQUIRED SPECIAL INSTRUCTIONS
In addition to the regular inspections, the
following checked items will also require
Special Inspection in accordance with Sec 306
of the Uniform Building Code.
ITEM REQ. IF REMARKS
CHECKED
SOILS COMPLIANCE
PRIOR TO
FOUNDATION INSP.
STRUCTURAL CONCRETE
OVER 2500 PSI
PRESTRESSED ST..
FIELD WELDING
HIGH STRENGTH BOLTS
EXPANSION ANCHORS
SPECIAL MASONRY
SPRAYED ON FIRE
PROOFING
PILES/CAISSONS
DESIGNER-SPECIFIED
OTHER
Exterior walls closer than 3 feet to property
I lines shall be one-hour rated construction and
have no openings. Table 5-A.
Plans, specifications and calculations shall be
signed by the California state licensed
engineer or architect responsible for their
preparation, for plans deviating from
conventional wood frame construction. Specify expiration date of license. (California
Business and Professions Code).
0
0
12/11/89 2
yL Exterior walls closer than 3 feet to a property 23. Openable window area in habitable rooms must line shall have 30 inch parapets when the floor be 1/20 of the floor area and a minimum of 5 area per floor exceeds 1,000 square feet. square feet. In bathrooms, laundry rooms and Section 1709. similar rooms 1/20 of area is required and
minimum is 1.5 sq. ft. Section 1205 (a). including Projections, eaves, may not extend / / more than 12 inches into the 3 foot setback Zf. At least 1/2 of the common wall must be open from the property line. Section 1710. and have an opening not less than 25 sq. ft.
nor one tenth of the floor area of the i. Eaves over required windows shall be not less interior room if light and ventilation is I than 30 inches from the side and rear property being supplied from an adjacent room. Section lines. Section 504. 1205 (a).
Plastic skylights shall not be installed within
that portion of •a roof located within a
distance to property line where openings in
exterior walls are prohibited or required to be protected. Section 5207 (a) 7.
Projections, including eaves, shall be one-hour fire-resistive construction, heavy timber or of noncombustible material if they project into the 3' setback area from the property line. Section 1710.
Show location of permanently wired smoke
detector:
(j) Centrally located in corridor or area giving access to sleeping rooms. () On each story.
In the basement.
d When sleeping rooms are upstairs, at the upper level in close proximity to the stair.
In rooms adjacent to hallways serving
bedrooms, when such rooms have a ceiling
height 24 inches or more above the ceiling
height in the hallway.
NOTE: Detectors shall sound an alarm audible in all sleeping areas of the unit. Section 1210
When the valuation of a room addition or repair
exceeds $1,000, or when sleeping rooms are created, smoke detectors shall be provided at
existing bedrooms per item 19 above. Section
1210.
GEROLAL RThflL KJ1K
Habitable rooms, other than kitchens, shall contain at least 70 square feet of floor area. At least one room shall have not less than 120
square feet of floor area. Section 1207 (b).
22. Window area must be at least 1/10 of the floor
area and a minimum of 10 square feet per
Section 1205 (a). Appears to be deficient in
/77ILY 200n.. - Peen i Rm. a-, LMEL USe 4-m.
0'. Required windows shall not open into a roofed
porch unless the ceiling height is at least 7
feet, the longer side is at least 6596 open,
and the porch abuts a street, yard or court.
Section 1205 (a).
2. Provide mechanical ventilation capable of
providing five air changes per hour in
bathrooms, water closet compartments, laundry
rooms and similar rooms if required openable windows are not provided. Section 1205 (c).
Show discharge point for exhaust air to be at
least 5 feet from any mechanical ventilating
intake. Section 1205(c).
Ductless fans cannot be used in bathrooms if a tub or shower is present. Section 1205(c).
2/. No habitable room, other than a kitchen, shall
be less than 7'0" in any dimension. Section
1207 (c).
Show that ceiling height for habitable rooms
is a minimum of 716". Section 1297 (a).
Show ceiling height for laundry rooms,
hallways, corridors, and bathrooms is a
minimum of 7'0". Section 1207 (a).
Dimension on the plans the 30" clear width for water closet compartments and 24" clearance in front of water closet. Section 511 (a).
3/. Specify safety glazing for glazing in
hazardous locations such as glass doors,
glazing adjacent to doors and glazing adjacent
to walking surfaces. Section 5406.
3/. Glazing, in the same wall plane as a door,
must be safety glazing if within 12" of the
door and less than 60" above the walking
surface, unless the glazing is leaded or
faceted glass. Section 5406 (d) 6.
35. Glazing in shower and tub enclosures shall be tempered, laminated or approved plastic
(including windows within 5 feet of tub or
shower floor). Section 5406 (d) 5.
2/12/90 : 3
s6. Provide spiral stairway details, per Section
/ 3306 (f):
Minimum run is 7 1/2 inches measured at a
point 12 inches from where the treads are the narrowest.
Maximum rise is 9 1/2 inches. Maximum
clear opening between risers is 6 inches.
C. Minimum headroom is 6 feet 6 inches
d. The tread must provide a clear walking
area measuring at least 26 inches from the
outer edge of the supporting column to the
inner edge of the handrail.
Spiral stairways may not be used for required I exits when the area served is . greater than 400 sq. ft. Section 3306 (f).
j2. Provide I.C.B.0. Research Report and number for I metal stairway, or submit plans and
calculations and approved fabricator registered
with the building department or note that the
stairway fabrication plans shall be submitted
to and approved by the building official prior
to installation.
5/. Exterior stairways shall not project into the 3
/ foot setback from the property lines. Section
3306 (n).
54. The walls and soffits of the enclosed usable
space under interior stairs shall be protected
on the enclosed side as required for one-hour
fire-resistive construction. Section 3306 (m).
Within units, show that corridors have a 7 minimum width of 36 incheS. Section 3305 (b).
ROOFThG
5/. Specify roof slope.
57/. Roof slope is not adequate for roof type
specified. Table 32-B,C,D and E.
Specify roof material and application. Chapter
32.
Specify I.C.B.0. or U.L. approval number for
roof materials not covered in U.B.C., e.g.,
tile, etc. Section 107.
Specify minimum 1/4 inch per foot roof slope
for drainage or design to support accumulated
water. Section 3207 (a) and Section 2305 (f).
4. Show roof drains and overflows. Section 3207.
6/ Provide skylight details to show compliance I with Sections 3401 and 5207 or provide
I.C.B.0. approval number.
Plastic skylights must be separated from each
other by at least 4 feet. Section 5207 (a) 6.
§.. Show attic ventilation. Minimum vent area is
1/150 of attic area or 1/300 of attic area if
at least 50% of the required vent is at least
3 feet above eave vents or cornice vents.
Show required area and area provided.
Section 3205 (c).
6. Provide fireplace construction details or note
I construction to be per attached fireplace
standard drawing. Chapter 37.
§6. Show anchored veneer support and connections
attached to wood in Seismic Zones 3 and 4,
comply with Section 3006 (d)l and Section 2515
(a). Show ties and ('9 wire in horizontal
joints.
64. Show height and construction details of all
masonry walls. Chapter 24.
6. Show floor and roof connections to masonry
walls. Connection shall resist 200 pounds per
lineal foot or the actual design load,
whichever is greater. Cross grain tension or
bending in wood ledgers is not permitted.
Section 2310.
6. Show a minimum V air space and flashing / between planter and building walls.
Section 2516 (c) 7.
S GARAGE AND CARP0tS
Garage requires one-hour fire protection on
the garage side of walls and ceiling common to
the dwelling. Table 5-B, Section 503 (d).
7
I. All elements supporting floor above garage,
including walls supporting floor joists, must
have one-hour fire-resistive protection on the - garage side. Section 503 (b)
72. Show 1 3/8" solid core self-closing door for
openings between garage and dwelling. Section
503 (d).
71. Garages are not permitted to open into a room
I used for sleeping purposes. Section 1104.
12/11/89 5
7I. An occupancy separation is not required between
carport and residence, provided the carport is
open on two or more sides and has no enclosed
uses above. Section 503 (a) Exception 3.
7j. Show garage framing sections, size of header I over garage opening, lateral cross bracing at
plate line, method bracing garage front and
holddowns if required. Chapter 23.
NOTE: Maximum shear panel height-to-width ratio is 3 1/2 to 1 for plywood. Table 25-I.
7/. Doors may open into the garage only if the
floor or landing in the garage is not more than
one inch lower than the.door threshold.
Section 3304 (i).
/7. Provide an 18" raised platform for any FAU,
water heater, or other device in the garage
which may generate a flame or spark. UMC
Section 508, UPC Section 1310 (a).
FOUNDATION RJIRS
Per soils report, note on the plan the soils
classification, whether or not the soil is
expansive and note the allowable bearing value. Section 2905 (c).
/9. The foundation plan does not comply with the soils report recommendations for this project.
Please review the report and modify design,
notes and details as required to show
compliance:_______________________________
4. Provide notes on the foundation plan listing
the soils report recommendation for
foundations, slab and building pad preparation.
ql. Provide a letter from the soils engineer
confirming that the foundation plan, grading
plan and specifications have been reviewed and that it has been determined that the
recosssendations in the soils report are
properly incorporated into the construction
documents (when required by the soil report).
IZ The soils engineer recommended that.he/she
review the foundation excavations. Note on
the foundation plan that "Prior to the
contractor requesting a Building Department
foundation inspection, the soils engineer
shall advise the building official in writing
that:
The building pad was prepared in
accordance with the soils report,
The utility trenches have been properly
back.filled and compacted, and
The koundation excavations comply with
the intent of the soils report".
83. Show height of all foundation walls. chapter 23. riorwAu....s
Show height of retained earth on all
foundation walls. Chapter 23.
If cut or fill slopes exist, show distance of
foundation to edge of cut or fill slopes and
show steepness and heights of cuts and fills.
Chapter 29.
Note on plans that wood shall be 6" minimum
G
m
above finish grade. Section 2907 (a).
aJ. Note on plans that surface water will drain
away from building and show drainage pattern
and key elevations. Section 2905 (f).
88. Dimension foundation per U.B.C. Table 29A:
Floors Footin
Supported* Stemwall Width Depth Thickness
3. 6" 12" 12" 6I1
2 8" 15" 18" 7"
3 10" 18" 24" 8"
*Foundations may support a
floors. Where only a
foundation for one floor.
roof in addition to the
roof is supported, use
89. Show foundation sillS to be pressure treated,
or equal. Section 2516 (c) 3.
M. Show foundation bolt size and spacing.
Section 2907 (f).
91. Specify size, I.C.B.O. number and manufacturer
of power driven pins. Show edge and end
distances and spacing. Section 302 (d).
2/13/90 6
If required, show size, imbedment and location
of hold down anchors on foundation plan.
Section 302 (d).
If hold downs are required, note on plan that
hold down anchors must be tied in place prior
to foundation inspection. Section 305 (e) 1.
Show adequate footings under all bearing walls
and shear walls. Section 2907 (b).
9A. Show on the plans stepped footings for slopes
I steeper than 1:10. Section 2907 (c).
9J. Show minimum 18" clearance from grade to bottom
I of floor joists and minimum 12" clearance to
bottom of girders. Section 2516 (c) 2.
9. Show pier size, spacing and depth -. into
undisturbed soil. Table 29-A.
Show minimum underfloor access of 18" x 24".
Section 2516 (c).
Show minimum underfloor ventilation equal to 1
sq. ft. for each 150 sq. ft. of underfloor
area. Openings shall be as close to corners as
practicable and shall provide cross ventilation
on at least two approximately opposite sides.
Section 2516 (c) 6.
FRAMIPG
100 Show wall bracing. Every exterior wood stud
wall and main cross-stud partition shall be
braced at each end at least every 25. feet of
length with 2. x 4 diagonal let-in braces or
equivalent. Section 2511 (g) 3, Table 25-V.
11. In 2-story buildings, shear panels at the first
I story (at least 48 inches in width) shall be
located at each end or as near thereto as
possible and comprise at least 25 percent of
the linear length of the wall, or provide
design. Section 2517(g)3, Table 25-V.
iç/ 2. Note cross bridging or blocking. Floor joists
I and rafters 12" or more in depth shall be
supported laterally by bridging at intervals
not exceeding 8 feet, unless both edges are
held inline. Sec. 2506 (h), 2517(d) 6.
103 Show blocking at ends and at supports of floor
joists, rafters and trusses at exterior walls.
Section 2517 (d) 3, 2517 (h) 6.
1(4. Bearing partitions, perpendicular to joists,
I shall not be offset from supporting girders,
beans, walls or partitions, more than the depth of the joist. Section 2517 (d) 5.
19'S. Show rafter ties. Rafter ties shall be spaced
/ not more than 4 feet on center and be just
above the ceiling joists, where rafters and
ceiling joists are not parallel. Section 2517
(h) 4.
l(. Show rafter purlin braces to be not less than
45 degrees to the horizontal.
Section 2517 (h) S.
Show double top plate with minimum 48" lap
splice. Section 2517 (g) 2.
Show nailing will be in compliance with Table
25-Q.
Show or note fire stops at the following
locations per Section 2516 (f):
In concealed spaces of stud walls and
partitions, including furred spaces, at
the ceiling and floor levels and at 10
foot intervals along the length of the
wall;
() At all interconnections between concealed
vertical and horizontal spaces such as
occur at soffits, drop ceilings and cove
ceilings;
In concealed spaces between stair
stringers at the top and bottom of the
run and between studs along and inline
with the run of stairs if the walls under
the stairs are unfinished; and
() In openings around vents, pipes, ducts,
chimneys, fireplaces and similar openings
which afford a passage for fire at
ceiling and floor levels, with
noncombustible materials.
In duplexes, draft stops shall be provided in
( floor-ceiling assemblies and attics in line
with walls separating units and separating
units from coon areas.
9stud
Show stud size and spacing. Maximum allowable
heights: Bearing wall: 2 x4 and 2 x 6
max. 101 ; Non-bearing: 2 x 4 max. 141 , 2 x 6
max. 20'. Table 25-R-3.
112. Studs supporting two floors, a roof and
ceiling must be 3 x 4 or 2 x 6 at 16" o.c.
Table 25-R-3.
Note on A.I.T.C. Certificate of Compliance for
f glued laminated wood members shall be given to
the building inspector prior to installation.
Section 2505.
2/12/90 . 7
Show the size, location and type of all heating
and cooling appliances or systems.
Show source of combustion air to furnace, per
Chapter 6, UMC.
)Every dwelling unit shall be provided with
heating facilities capable of maintaining a
room temperature of 70 degrees F. at 3 feet
above the floor in all habitable rooms. Show
1,udc for compliance. USC, Sec. 1212.
Show minimum 30" deep unobstructed working
space in front of furnace. 'Section 505, UMC.
Furnace shall not be installed in any bedroom,
bathroom or in a closet or confined space with
access only through such room unless
specified as direct vent appliance, enclosed
furnace or electric heating appliance. -
Section 704 UMC.
Show I.C.B.0. approval number for prefab
fireplace. Show height of chimney above roof
per I.C.B.0. approval or Table 37-B.
Show access to the attic containing equipment
to be minimum 30 inches by 30 inches. The
opening may be 22 inches by 30 inches if the
equipment can be removed through such opening.
Section 708 UMC.
Where equipment is installed in the attic, the
distance from the attic access to such
equipment shall not exceed 20 feet.
Note that passageway to the attic furnace shall
be unobstructed and have continuous solid
flooring not less than 24 inches wide.
Section 708 UMC.
Show permanent electrical outlet and lighting
fixture controlled by a switch for the attic
furnace. Section 708 UMC.
Show details to comply with Section 709 for
furnace under the floor, or Section 710 for
roof or outside furnace.
Note on plan: Gas vents and non-combustible
/ piping, in walls, passing through three floors
or less shall be effectively draft stopped at
each floor or ceiling.
USC, Section 1706 (a) 6.
Provide dryer vent to outside. UMC, Section
3903.
All wiring shall comply with the National
Electrical Code.
11. Show on the plan the amperage of the
electrical service, the location of the
service panel and the location of any sub-
panels. If service is over 200 amps, submit
single line diagram, panel schedule and load
calculations.
Show location of all electrical receptacles.
153 Electrical receptacle locations and/or spacing
is not adequate in PL I. &)EaJ 2..)on .s.
Show at least one convenience outlet other
than outlets for laundry, etc., outdoors, in
garages and basements. NEC, Art. 210-52.
Note convenience outlets in bathrooms, kitchen
counter top(s) within 6 feet of the kitchen
sink, outdoors • and in earaves and basements
(other than for laundry and similar equipment)
shall be GFI protected. NEC, Art. 210-8.
15. Note electrical system ground to be provided
per NEC, Art. 250-81.
PLThG (UNU4 PLt} OE
l4. Show water heater sire, type and location on 1 plans. UPC, Section 1301.
1
8. Show source for providing combustion air to I fuel burning water heater. If wall openings
in an enclosure are used, at least one-half of
the required opening area shall extend into
the upper twelve inches of the enclosure and
one-half within the lower twelve inches. UPC,
Section. 1307.
19. Fuel combustion water heater shall not be
installed in bath or bedrOom or in a closet
opening into bath or bedroom. UPC, Section.
1309.
l69. Provide adequate barrier to protect water
f heater from vehicle damage. An 18" platform
for the water heater doss not satisfy this
requirement. UPC, Section 1310.
lE.. Show T and P valve on water heater and show
I route of discharge line to exterior.
UPC, Section 1007 (e).
9/90 ' 9.
lZ. Show that water heater is adequately braced to
resist seismic forces, when not connected by
rigid pipe. UMC Section 504(d).
16,L Show shower stall can accommodate a 30" circle
and has a minimum floor area of 1,024 sq. in.
UPC 909 (d).
14. Provide clothes washer hook-up for each unit.
Title 24, Part 3.
NOISE INSULATION (1XJPLUS)
i$. Show details of duplex common (party) walls and
floor/ceiling assemblies to achieve a Sound
Transmission Class (STC) rating in walls of 50
decibels and an Impact Insulation Class (IIC)
rating on floor/ceiling of-.50 decibels..
Title 24.
16k. Show how penetrations of assemblies for piping,
electrical devices, recessed cabinets,
bathtubs, soffits, or heating ventilating, or
exhaust ducts shall be sealed, lined, or
insulated to maintain required sound
transmission rating. Title 24.
l7. Provide insulation in walls and ceiling to
achieve STC of 50 between garage and living
area if garage use is not controlled, by
resident. Title 24.
EMERGr CONSERVATION
1. Provide plans, calculations and worksheets to
1 show compliance with current energy standards.
144. The regulations require a properly completed
( and properly signed Form CF-1R to be either
imprinted on the plans, taped to the plans or
"sticky backed" on the plans, to allow the
building inspector to readily compare the
actual construction with the requirements of
the approved energy design.
1
.
0. All energy items shown on the plans must be in
agreement with the information shown on the
properly completed Form CF-1R.
S
Specify on the building plans all of the
mandatory energy conservation requirements as
listed on the enclosure titled, "Mandatory
Energy Conservation Requirements".
112. Show the make, model and efficiency of the
space heating (or cooling) system and provide
heat loss calculations if the output exceeds
45,000 BTU/Hr.
S
For room additions, show that the glazing area
of the addition does not exceed 16% of the
newly-conditioned floor area, plus glazing
removed or relocated due to the addition.
17 Provide fluorescent general lighting in
I kitchen(s) per CAC, Title 24, 2-5352(J).
CARLSBAD S.F.D. & DUPLEX SUPPLE(
•iib. Energy conservation design should be for Zone
7.
16. Floor drains must have auto-prime (city
policy).
177. Note exhaust fans cannot be ductless type
(city policy).
1/8. New residential units must be pre-plumbed for
j future solar water heating. Note "two roof
jacks must be installed" where the water
heater is in the one story garage and directly
below the most south facing roof (City
Ordinance No. 8093).
l7. Note "two 3/4" copper pipes must be installed
I to the most convenient future solar panel
location when the water heater is not in a one
story garage and is not directly below the
most south facing roof. (City Ordinance No.
8093).
181). All piping for present or future solar water
/ heating must be insulated• when in areas that
are not heated or cooled by mechanical means
(city policy).
4. Incorporate the waterproofing details, on the
attached Policy 80-8, where interior living
space occurs below grade at the masonry
wall(s).
ilz. Show on the Title Sheet on the plans, the
information required by the attached
Developmental Services Sheet 112383.
13. All new residential buildings, including
( additions, require a soils report. Please
submit two copies. Exception: If a room
addition is limited to one story and 1000 sq.
ft. in area, then a soils report is not
required. Esgil Corporation will advise the
City to place their soils notice stamp on the
plans.
14.. Heavy timber framing, minimum 6" x 10" beams
and minimum 8" x 8" post, for the structural
beam and column supporting the fire separation
between the garage and living area above, is
acceptable if shown on the plans. (city
policy).
2/26/90 10
CONTADa:D Je:s. JOB SPE=CAnC))(
All heating, ventilating, air conditioning, and water heating equipment shall meet all of the
requirements of the Appliance Efficiency Standards and shall be certified by the California Energy
Commission. -
A two stage thermostat, which controls the supplementary heat on its second stage, shall be
provided for-heat pumps.
Thermostats shall be equipped with an automatic setback, which the building occupant can program to
automatically set back the thermostat twice in 24 hours.
Equipment which requires preventive maintenance to maintain efficient operation shall be furnished
with complete necessary maintenance information.
All gas-fired fan type central furnaces, gas-fired fan type wall furnaces, and cooking appliances
shall be equipped with an intermittent ignition device.
All fan systems exhausting air to the outside shall be provided with backdraft dampers.
All transverse duct, plenun, and fitting joints shall be sealed with pressure sensitive tape or
mastic to prevent air loss and shall—be insulated to conform to the provisions of Section 1005 of
the UMC, 1982 Edition.
A vapor barrier is required in c1ite zone 1, iZe, and 16.
All manufactured windows and sliding glass doors shall meet the 1972 ANSI air infiltration
standards and shall be certified and labeled.
All swinging doors and windows leading to unconditioned areas shall be fully weather-stripped.
Storage type water heaters and storage and backup tanks for solar systems shall be externally
wrapped with R-12 insulation or greater.
(11) The five feet of pipe closest to the water heater, if outside conditioned space, shall be insulated
with a minimum of R-3. Steam and steam condensation return piping and recirculating hot water
piping outside the building envelope shall be-insulated in accordance with 120-1406(d).
(13) Lamps used in luminaries for general lighting in kitchens and bathrooms shall have an efficiency of
not less than 25 lumens per watt.
(lie) Showerheads and faucets shall be equipped with flow restrictors as outlined in the appliance
efficiency standards and shall be certified to the Energy Commission.
Masonry and factory-built fireplaces on exterior walls, shall be equipped with tight-fitting
closeable metal or glass doors covering the entire opening of the firebox; a combustion air intake
equipped with a readily accessible, operable, and tight fitting damper to draw air from the outside
of the building; and a tight fitting flue damper with a readily accessible control.
Insulation used shall comply with California Quality Standards.
The insulation installer shall. post. a signed certificate. ..Section. 276. Insulation Certificate
(All Occupancies). After installing insulation, the installer shall post in a conspicuous location
in the building a certificate signed by the installer and the builder stating that the installation
conforms the requirements of Title-24, Part 2, Chapter 2-53, and that the materials installed
conform with the requirements of Title 20, Chapter 2, Subchapter 4, Article 3. The certificate
shall state the manufacturer's name and material identification, the installed "R" value, and (in
applications of loose fill insulation) the minimum installed weight per square foot consistent with
the manufacturer's labeled density for the desired 11R" value.
For infiltration control all openings and penetrations must be caulked and sealed, such as around
windows, at sole plates, and openings for utility pipes and wires.
Form ECI 3/5/86
ESGIL CORPORATION
9320 CHESAPEAKE DR., SUITE 208
SAN DIEGO, CA 92123
(619) 5601468
DATE: - 'm (/4 29 190
,JURISDICTION: CARLSBAD
PLAN CHECK NO: SET:T'
PROJECT ADDRESS:c75I/ -
PROJECT NAME: S/ b JDLe p
JURISDICTION
FILE COPY
UPS
DESIGNER
Ej The plans transmitted herewith have been'-
'
corrected where
necessary and substantially comply with te jurisdiction's
building codes.
The plans transmitted herewith will substantially comply U with the jurisdiction's-building codes when minor deficien-
cies identified are resolved and
checked by building department staff..
The plans transmitted herewith have significant deficiencies
identified on the enclosed check list and should be corrected
and resubmitted.f or a complete recheck.
The check list transmitted herewith is for your information.
The plans are being held at Esgil Corp. until corrected
plans are submitted for recheck.
The applicant's copy of the check list is enclosed for the
jurisdiction to return to the applicant contact person.
The applicant's copy of the check list has been sent to:
;a , CA Pr8R-L-01)
Esgil staff did not advise the applicant contact person that
plan check has been completed.
U Esgil staff did advise applicant that the plan check has
been completed. Person contacted:_______________________
Date contacted:. . Telephone #________________ 0 REMARKS:
Enclosures: fAJERy
- - ESGIL CORPORATION-
0 GA .0 AA Dvw 0DM
PUN NO: _________________
JURISDICrICN: CITY OF CARlSBAD
TO: 7t1 $44121)
8,1 2 CAPE 7z,)
Pmm= ADDRESS:c7gi) frIJfE.S7
FWORANE&: (oi5
REMARKS:
Plan check is limited to technical requirements
contained in the Uniform Building Code, Uniform
Plumbing Code, Uniform Mechanical Code, National
Electrical Code and state laws regulating energy
conservation, noise attenuation and access for the
handicapped. The plan check is based on
regulations enforced by the Building Inspection
Department. You may have other corrections based
on laws and ordinances by the Planning Department,
Engineering Department or other departments.
Present California law mandates that residential
construction comply with Title 24 and the following
model codes:
1988 UBC (eff. 1/1/90)
1988 UPC(eff. 1/1/90)
1987 NEC (eff. 10/28/87)
1988 UMC (eff. 1/1/90)
The above regulations apply to residential
construction, regardless of the code editions
adopted by ordinance.
The circled items listed need clarification,
modification or change. All items have to be
satisfied before the plans will be in conformance
with the cited codes and regulations. Per Sec.
303(c), 1988 Uniform Building Code, the approval of
the plans does not permit the violation of any
state, county or city law.
To speed un the recheck process, note on this list
(or a copy) where each correction item has been
addressed i.e., plan sheet, specification, etc. Be
sure to enclose the marked um list when you submit
the revised plans.
PLAN C(*x&ri(NI SRKWr
cm OF CASBAD
SINGLE FANnY AND DUPLICK DVELLINGS
Date plans received by jurisdiction:
Date plans received by Esgil Corporation:
Date initial plan check completed:
3 - 9O By: £. FAWS
Applicant contact person:
__Telephone: 59S' -9v5
NIX: PACE NIJIBS ARE NOT IN SZQ=CK AS PAGES HAVING ND IEM NUIG axI4S WREE TRT •
List No. 12, Carlsbad Single Family Dwelling and Duplex With All Supplements. (1988 UBC)
PLANS 10. Show on the title sheet all structures, pools,
1. Please make all corrections on the original
walls, etc. included under this application.
Any portion of the project shown on the site tracings and submit two new sets of prints, and plan that is not included with the building any original plan sets that may have been permit application filed should be clearly returned to you, by the jurisdiction, to: identified as "not included.".
Esgil Corporation, 9320 Chesapeake Drive, 11. Clearly show if the lower level is a basement Suite #208, San Diego, California 92123, or a story, based on the definitions in
2.
(619) 560-1468.
Please make all
Sections 403 and 420. Plot the finish grade
(as defined) on the elevations and dimension.
corrections on the original ' the distance to the floor above, for story tracings and submit two new sets of prints, determination. and any original plan sets that may have been
returned to you by the jurisdiction, to: 12. On the cover sheet of the plans, specify any
items requiring special inspection, by way of The jurisdiction's building department. the following:
Indicate on the Title Sheet of the plans, the REQUIRED SPECIAL INSTRUCTIONS the legal name of owner and name of person In addition to the regular inspections, the
responsible for the preparation of the plans. following checked items will also require Section 302(a)7. Special Inspection in accordance with Sec 306
of the Uniform Building Code.
All sheets of plans must be signed by the person responsible for their preparation. ITEM REQ. IF R1ARXS
___
(California Business and Professions Code). CHECKED
Plans, specifications and calculations shall be
SOILS COMPLIANCE
PRIOR TO signed by the California state licensed FOUNDATION INSP. engineer or architect responsible for their
preparation, for plans deviating from STRUCTURAL CONCRETE
conventional wood frame construction. Specify OVER 2500 PSI expiration date of license. (California
Business and Professions Code). PRESTRESSED ST..
Specify on the Title Sheet of the plans the FIELD WELDING gross floor area of each element of this
project including dwelling, garage, carport, HIGH STRENGTH BOLTS patio, deck and balcony. Section 302(d).
Provide a statement on the Title Sheet of the
EXPANSION ANCHORS
plans that this project shall comply with Title SPECIAL MASONRY 24 and 1988 UBC, UMC and UPC and 1987 NEC.
SPRAYED ON FIRE Submit fully dimensioned plot plan. drawn to PROOFING scale showing location, size, and use of all existing and proposed structures on the lot. PILES/CAISSONS Identify property lines and show lot dimensions
and all easements. Show location of all cut or DESIGNER-SPECIFIED fill slopes. Show finish floor elevations and
show elevations of adjacent finish grade. OTHER Show drainage patterns with minimum slopes. Section 302(d). -
FIRE PROION Indicate distance from property lines to
proposed building. Section 302(d). / 1/. Exterior walls closer than 3 feet to property
I lines shall be one-hour rated construction and
have no openings. Table 5-A.
12/11/89 . . . 2
Exterior walls closer than 3 feet to a property
line shall have 30 inch parapets when the floor
area per floor exceeds 1,000 square feet.
Section 1709.
. ProjectEions,t including eaves, may not extend / more than 12 inches into the 3 foot setback
from the property line. Section 1710.
1/. Eaves over required windows shall be not less
I than 30 inches from the side and rear property lines. Section 504.
Plastic skylights shall not be installed within
that portion of a roof located within a
distance to property line where openings in
exterior walls are prohibited or required to be
protected. Section 5207 (a) 7.
Projections, including eaves, shall beone-
hour fire-resistive construction, heavy timber
or of noncombustible material if they project into the 31 setback area from the property
line. Section 1710.
Show location of permanently wired smoke
detector: ® Centrally located in corridor or area giving access to sleeping rooms.
On each story.
In the basement.
d When sleeping rooms are upstairs, at the
upper level in close proximity to the
stair.
() In rooms adjacent to hallways serving
bedrooms, when* such rooms have a ceiling height 24 inches or more above the ceiling
height in the hallway.
NOTE: Detectors shall sound an alarm audible in
all sleeping areas of the unit. Section 1210
When the valuation of a room addition or repair
exceeds $1,000, or, when sleeping rooms are
created, smoke detectors shall be provided at
existing bedrooms per item 19 above. Section 1210.
GEMMAL R1DITIAL K&JIR
Habitable rooms, other than kitchens, shall
contain at least 70 square feet of floor area.
At least one room shall have not less than 120
square feet of. floor area. Section 1207 (b).
22. Window area must be at least 1/10 of the floor area and a minimum of 10 square feet per
Section 1205 (a). Appears to be deficient in
23. Openable window area in habitable rooms must be 1/20 of the floor area and a minimum of 5
square feet. In bathrooms, laundry rooms and
similar rooms 1/20 of area is required and
minimum is 1.5 sq. ft. Section 1205 (a).
At least 1/2 of the common wall must be open
and have an opening not less than 25 sq. ft.
nor one tenth of the floor area of the
interior room if light and ventilation is
being supplied from an adjacent room. Section
1205 (a). 3.'. Required windows shall not open into a roofed
porch unless the ceiling height is at least 7
feet, the longer side is at least 65% open,
and the porch abuts a street, yard or court.
Section 1205 (a).
2. Provide mechanical ventilation capable of
providing five air changes per hour in
bathrooms, water closet compartments, laundry
rooms and similar rooms if required openable
windows are not provided. Section 1205 (c).
Show discharge point for exhaust air to be at
0 least 5 feet from any mechanical ventilating
intake. Section 1205(c).
Ductless fans cannot be used in bathrooms if a tub or shower is present. Section 1205(c).
2/. No habitable room, other than a kitchen, shall
be less than 710" in any dimension. Section
1207 (c).
Show that ceiling height for habitable rooms
is a minimum of 7'6". Section 1207 (a).
Show ceiling height for laundry rooms,
hallways, corridors, and bathrooms is a
minimum of 710". Section 1207 (a).
Dimension on the plans the 30" clear width for
water closet compartments and 24" clearance in
front of water closet. Section 511 (a).
3/. Specify safety glazing for glazing in
hazardous locations such as glass doors,
glazing adjacent to doors and glazing adjacent
to walking surfaces. Section 5406.
3/. Glazing, in the same wall plane as a door,
must be safety glazing if within 12" of the door and less than 60" above the walking
surface, unless the glazing is leaded or
faceted glass. Section 5406 (d) 6.
G
Glazing in shower and tub enclosures shall be
tempered, laminated or approved plastic
(including windows within 5 feet of tub or
shover floor). Section 5406 (d) 5.
2/12/90 . . . 3
3 ' Sleeping rooms shall have a window or exterior 45. Provide stairway and landing details. Section
' door for emergency exit. Sill height shall not 3306 (b), (c) and (p). exceed 44" above the floor. The window must have an openable area of at least 5.7 square Maximum rise is 7" and minimum run is feet with the minimum openable width 20" and 1111. When the stairs serves less than 10 the miiiimt'm openable height 26". Section 1204. occupants, or serves an unoccupied roof, / rise may be 8" maximum and run 9" 3/. Basements in dwelling units shall comly with minimum. the above (even if not designated as sleeping rooms). Section 1204. Minimum headroom is 61-611. (per Title 24)
3p' Walls and floors separating units in a duplex C. Minimum width is 36". shall be of one-hour fire-resistive construction. Section 1202(b). 46. All handrails per Section 3306 (i), shall satisfy the following: 3ft. A mezzanine is an intermediate floor and may ( not have a floor area exceeding 33 1/3 percent Provide handrail for stairways with 4 or of the total floor area in the room below. The more risers. mezzanine floor must have a clear height of 7 feet, above and below, and must have the long Handrail shall be 34" above the nosing of side open to the room below except for posts treads. (per Title 24) and protective walls or railings not exceeding
42" in height. Section 1716. C. The handgrip portion of handrail shall be I not less than 1 1/211, nor more than 2" in j0. The loft you show does not comply as a cross-sectional dimension. mezzanine floor and is, by Uniform Building j Code definition, a story. Section 1716. 7. Every stairway landing shall have a dimension,
measured in the direction of travel, at least XlI. SIAI1AIS AND RAILINGS equal to the stairway width. Such dimension
Floors above the second story shall have not
need not exceed 36 inches. Section 3306 (g),
I less than 2 exits. Exceptions: 1. Occupied 3304 (j). roofs may have one exit if such occupied areas
are less than 500 square feet and located no 1/8. An interior door may open inward at the top higher than immediately above the second story. I step of a stairway provided the top step is 2. When the third floor within a unit does not not more than 7 1/2" lower than the floor exceed 500 sq. ft., only one exit need be level. Section 3304 (i). provided. Section 3303(a).
42. Required exit doorways shall be not less than
Provide details of winding stairway complying
I with Section 3306 (d): / 36" in width and not less than 6'8" in height,
and shall be capable of opening at least 90 Minimum tread is 6 inches at any point degrees. Section 3304 (f). and minimum 9 inches at a point 12 inches
/ from where the treads are narrowest. Provide 36" high protective railing for porches, balconies, and open sides of stair Maximum rise is 8 inches. landings. Openings between railings shall be
less than 6". Section 1711. C. Minimum width is 36 inches.
Show how guardrail connection details are
I adequate to support 20 pounds per lineal foot at a right angle to the top rail. Table 23-B.
2/12/90 - 4
56. Provide spiral stairway details, per Section
/ 3306 (f):
Minimum run is 7 1/2 inches measured at a
point 12 inches from where the treads are
the narrowest.
Maximum rise is 9 1/2 inches. Maximum
clear opening between risers is 6 inches.
C. Minimum headroom is 6 feet 6 inches
d. The tread must provide a clear walking
area measuring at least 26 inches from the
outer edge of the supporting column to the
inner edge of the handrail.
Spiral stairways may not be used for required
I exits when the area served 1's . greater than 400 sq. ft. Section 3306 (f).
42. Provide I.C.B.O. Research Report and number for metal stairway, or submit plans and calculations and approved fabricator registered
with the building department or note that the
stairway fabrication plans shall be submitted
to and approved by the building official prior to installation.
5/. Exterior stairways shall not project into the 3 I foot setback from the property lines. Section
3306 (n).
54. The walls and soffits of the enclosed usable
space under interior stairs shall be protected on the enclosed side as required for one-hour
fire-resistive construction. Section 3306 (m).
!i. Within units, show that corridors have a
/ minimum width of 36 inches. Section 3305 (b).
R00Yfl
5/. Specify roof slope.
57/. Roof slope is not adequate for roof type
specified. Table 32-B,C,D and E.
h. Specify .roof material and application. chapter 32.
5. Specify I.C.B.0. or U.L. approval number for 4- roof materials not covered in U.B.C., e.g.,
tile, etc. Section 107.
Specify minimum 1/4 inch per foot roof slope
for drainage or design to support accumulated
water. Section 3207 (a) and Section 2305 (f).
6k.. Show roof drains and overflows. Section 3207.
6/ Provide skylight details _to show compliance
' with Sections 3401 and 5207 or provide
I.C.B.0. approval number.
Plastic skylights must be separated from each
other by at least 4 feet. Section 5207 (a) 6.
.. Show attic ventilation. Minimum vent area is
I 1/150 of attic area or 1/300 of attic area if
at least 50% of the required vent is at least
3 feet above cave vents or cornice vents.
Show required area and area provided. Section 3205 (c).
61. Provide fireplace construction details or note
f construction to be per attached fireplace
standard drawing. Chapter 37.
ff6. Show anchored veneer support and connections
( attached to wood in Seismic Zones 3 and 4,
comply with Section 3006 (d)l and Section 2515
(a). Show ties and #9 wire in horizontal
joints.
61. Show height and construction details of all
masonry walls. Chapter 24.
6. Show floor and roof connections to masonry
walls. Connection shall resist 200 pounds per
lineal foot or the actual design load,
whichever is greater. Cross grain tension or
bending in wood ledgers is not permitted.
Section 2310.
6. Show a minimum 2" air space and flashing
f between planter and building walls.
Section 2516 (c) 7.
GARAGE AND CARPORTS
(:70.) Garage requires one-hour fire protection on
the garage side of walls and ceiling common to
the dwelling. Table 5-B, Section 503 (d).
7(. All elements supporting floor above garage,
I including walls supporting floor joists, must
have one-hour fire-resistive protection on the
- garage side. Section 503 (b)
72. Show 1 3/8" solid core self-closing door for
openings between garage and dwelling. Section
503 (d).
7
I
. Garages are not permitted to open into a room
used for sleeping purposes. Section 1104.
12/11/89 5
-C'-
-•--. •' -•. ..,- -. • - -. - .-
71. An occupancy separation is not required between
carport and residence, provided the carport is
open on two or more sides and has no enclosed
uses above. Section 503 (a) Exception 3.
7j. Show garage framing sections, size of header
f over garage opening, lateral cross bracing at
plate line, method bracing garage front and
holddowns if required. Chapter 23.
NOTE: Maximum shear panel height-to-width
ratio is 3 1/2 to 1 for plywood. Table 25-I.
i/. Doors may open into the garage only if the floor or landing in the garage is not more than
one inch lower than the door threshold.
Section 3304 (i).
/7. Provide an 18" raised platform for any FAU,
water heater, or other device in the garage
which may generate a flame or spark. UMC
Section 508, UPC Section 1310 (a).
FOUNDATION RJIRTS
Per soils report, note on the plan the soils
classification, whether or not the soil is
expansive and note the allowable bearing value.
Section 2905 (c). -
/9. The foundation plan does not comply with the
soils report recommendations for this project.
Please review the report and modify design,
notes and details as required to show
compliance:_______________________________
81). Provide notes on the foundation plan listing
" the soils report recommendation for
foundations, slab and building pad preparation.
qi. Provide a letter from the soils engineer
confirming that the foundation plan, grading
plan and specifications have been reviewed and
that it has been determined that the
.recommendations in the soils report are
properly incorporated into the construction
documents (when required by the soil report).
IZ The soils engineer recommended that he/she
review the foundation excavations. Note on
the foundation plan that "Prior to the
contractor requesting a Building Department
foundation inspection, the soils engineer
shall advise the building official in writing
that:
1. The building pad was prepared in
accordance with the soils report,
2. The utility trenches have been properly
backfilled and compacted, and
3. The foundation excavations comply with
the intent of the soils report".
83. Show height of all foundation walls. Chapter 23. xr -,a,o,t wa.s
Show height of retained earth on all
foundation walls. Chapter 23.
If cut or fill slopes exist, show distance of
foundation to edge of cut or fill slopes and
show steepness and heights of cuts and fills.
Chapter 29.
Note on plans that wood shall be 6" minimum
G
m
above finish grade. Section 2907 (a).
8/. Note on plans that surface water will drain
away from building and show drainage pattern
and key elevations. Section 2905 (f).
88. Dimension foundation per U.B.C. Table 29A:
Floors Footing
Supported Stenwall Width Depth Thickness
1 6" 12" 12" 6"
2 8" 15" 18" 7"
3 10" 18" 2411 8"
*Foundations may support a roof in addition to the
floors. Where only a roof is supported, use
foundation for one floor.
89. Show foundation sills to be pressure treated,
or equal. Section 2516 (c) 3.
90. Show foundation bolt size and spacing.
Section 2907 (f).
91. Specify size, I.C.B.0. number and manufacturer
of power driven pins. Show edge and end
distances and spacing. Section 302 (d).
2/13/90 - 6
-
If required, show size, imbedment and location
of hold down anchors on foundation plan. Section 302 (d).
If hold downs are required, note on plan that
hold down anchors must be tied in place prior
to foundation inspection. Section 305 (e) 1.
Show adequate footings under all bearing walls
and shear walls. Section 2907 (b).
94. Show on the plans stepped footings for slopes I steeper than 1:10. Section 2907 (c).
91. Show minimum 18" clearance from grade to bottom I of floor joists and minimum 12." clearance to
bottom of girders. Section 2516 (c) 2.
Show pier size, spacing and depth into
undisturbed soil. Table 29-A.
Show minimum underfloor access of 18" x 24".
Section 2516 (c).
Show minimum underfloor ventilation equal to 1
sq. ft. for each 150 sq. ft. of underfloor
area. Openings shall be as close to corners as
practicable and shall provide cross ventilation
on at least two approximately opposite sides.
Section 2516 (c) 6.
FRANIM
100 Show wall bracing. Every exterior wood stud
wall and main cross-stud partition shall be
braced at each and at least every 25 feet of
length with 1 x 4 diagonal let-in braces or
equivalent. Section 2517 (g) 3, Table 25-V.
11. In 2-story buildings, shear panels at the first I story (at least 48 inches in width) shall be
located at each end or as near thereto as
possible and comprise at least 25 percent of
the linear length of the wall, or provide
design. Section 2517(g)3, Table 25-V.
içI z. Note cross bridging or blocking. Floor joists I and rafters 12" or more in depth shall be
supported laterally by bridging at intervals
not exceeding 8 feet, unless both edges are
held inline. Sec. 2506 (h), 2517 (d) 6.
103 Show blocking at ends and at •supports of floor
joists, rafters and trusses at exterior walls.
Section 2517 (d) 3, 2517 (h) 6.
l(1e. Bearing partitions, perpendicular to joists,
I shall not be offset from supporting girders,
beams, walls or partitions, more than the depth
of the joist. Section 2517 (d) 5.
l9. Show rafter ties. Rafter ties shall be spaced
/ not more than 4 feet on center and be just
above the ceiling joists, where rafters and
ceiling joists are not parallel. Section 2517
(h) 4.
lc/6. Show rafter purlin braces to be not less than
45 degrees to the horizontal.
Section 2517 (h) S.
a
Show double top plate with minimum 48" lap
splice. Section 2517 (g) 2.
Show nailing will be in compliance with Table
25-Q.
Show or note fire stops at the following
locations per Section 2516 (f):
In concealed spaces of stud walls and
partitions, including furred spaces, at
the ceiling and floor levels and at 10
foot intervals along the length of the
wall;
At all interconnections between concealed 0
vertical and horizontal spaces such as
occur at soffits, drop ceilings and cove
ceilings;
In concealed spaces between stair
stringers at the top and bottom of the
run and between studs along and inline
with the run of stairs if the walls under
the stairs are unfinished; and
In openings around vents, pipes, ducts,
chimneys, fireplaces and similar openings
which afford a passage for fire at
ceiling and floor levels, with noncombustible materials.
In duplexes, draft stops shall be provided in
( floor-ceiling assemblies and attics in line
with walls separating units and separating
units from common areas.
9stud
Show stud size and spacing. Maximum allowable
heights: Bearing wall: 2 x4 and 2 x 6
max. 101; Non-bearing: 2 x 4 max. 141, 2 x 6
max. 201. Table 25-R-3.
112. Studs supporting two floors, a roof and
ceiling must be 3 x 4 or 2 x 6 at 16" o.c.
Table 25-R-3.
l]1. Note on A.I.T.C. Certificate of Compliance for / glued laminated wood members shall be given to
the building inspector prior to installation.
Section 2505.
2/12/90 . . 7
-
Detail all post-to-beam and post-to-footing connections and reference the detail to the
plan. Section 2516 (m).
Detail shear transfer connections, including
roof and floor diaphragms, to shear walls.
Section 2513.
Specify nail size and spacing for all shear
walls, floor and roof diaphragms. Indicate
required blocking. Maintain maximum diaphragm
dimension ratios. [Tables 25 I, 3, K and
Section 4714 (d)].
Y. Provide truss details and truss calculations
for this project. Specify truss identification
numbers on the plans.
118. Show 1/2" minimum clearance between top plate
of interior partitions and bottom chord of
trusses. (To ensure loading will be as
designed).
119. Provide roof framing plan and floor framing
plan. Section 302 (d).
120. Provide framing sections through
LOI)JTILDIOAL i)i rr/4sJ
Section 302 (d).
ui. Specify all header sizes for opening over 4'
wide. Section 2517 (g) 5.
1j2. Provide calculations for main vertical and
horizontal, framing members and post footings.
Section 302 (b).
Provide calculations for lateral loads, shear
panels, shear transfer and related. Section
302 (b).
In Seismic Zones 3 and 4, the allowable shear
wall values for drywall in Table 47-I must be
reduced 50 percent when considering earthquake
loads. This does not apply to wind loads.
Footnote 1.
l2. Show on the plans all structural requirements
developed in the structural calculations.
Section 302 (d). (See comments below' or at end.)
121. Columns and posts located on concrete or
f masonry floors or decks exposed to the weather
or to water splash or in basements and which
support permanent structures shall be
supported by concrete piers or metal pedestals
projecting above floors unless approved wood
of natural resistance to decay or treated wood
is used. Section 2516 (c) 4.
....1
1
7. j Individual concrete or masonry piers shall
project at least 8 inches above exposed ground
unless the columns or posts which they support
are of approved wood of natural resistance to
decay or treated wood is used.
Section 2516 (c) 4.
l2. Show location of attic access with minimum tI size 22" x 30". Section 3205.
Show draft separation for attic areas between
units in a duplex. Section 2516 (f).
34. Specify plywood and/or particle board
thickness, grade and panel identification
index. Table 25-S.
13l. When roof pitch is less than 3:12, design I ridge as a beam. Section 2517 (h).
112. If foundation cripple wall studs are less than
14" high, framing shall be solid blocking, or
sheathed with plywood. Section 2517 (g) 4.
13. Cripple wall studs exceeding 4 feet in height
shall be 3 inch by 4 inch or 2 inches by 6
inches when supporting 2 stories.
Section 2517 (g) 4.
13!e. Show plywood sheathing over exposed eaves, or
. other weather exposed areas, is "bonded with
exterior glue." Plywood used for exterior
wall covering shall be the exterior type.
Section 2516 (i), 2516(g)3.
115. Detail truss layout for 30" x 30" attic
access, if required for equipment in the
attic.
46. Ridges, hips, and valleys shall be at least
one size larger than supported rafters.
Section 2517 (h) 3.
7. In open beam construction, provide strap ties
across the beams at the ridge support.
Section 2501 (b).
MECHANICAL (UNIFORM NBMICAL UDR)
All heating, ventilating, and cooling systems and
appliances shall comply with the Uniform Mechanical
Code.
2/12/90 . 8
. mow the size, location and type of all heating
and cooling appliances or systems.
9. ShOW source of combustion air to furnace, per
Chapter 6, UMC.
0'Every dwelling unit shall be provided with
_Jheating facilities capable of maintaining a
room temperature of 70 degrees F. at 3 feet
above the floor in all habitable rooms. Show
for compliance. UBC, Sec. 1212.
rL Show minimum 30" deep unobstructed working
space in front of furnace. Section 505, UMC.
2. Furnace shall not be installed in any bedroom,
bathroom or in a closet or confined space with'
access only through such room unless
specified as direct vent appliance, enclosed
furnace or electric heating appliance. -
Section 704 UMC.
f3. Show I.C.B.0. approval number for prefab
fireplace. mow height of chimney above roof
per I.C.B.0. approval or Table 37-B.
Show access to the attic containing equipment I to be minimum 30 inches by 30 inches. The
opening may be 22 inches by 30 inches if the
equipment can be removed through such opening.
Section 708 UMC.
Where equipment is installed in the attic, the
distance from the attic access to such
equipment shall not exceed 20 feet.
6.• Note that passageway to the attic furnace shall
I be unobstructed and have continuous solid
flooring not less than 24 inches wide.
Section 708 UMC.
4. Show permanent electrical outlet and lighting
I fixture controlled by a switch for the attic
furnace. Section 708 UMC.
43. Show details to comply with Section 709 for
furnace under the floor, or Section 710 for
roof or outside furnace.
Note on plan: Gas vents and non-combustible _J piping, in walls, passing through three floors
or less shall be effectively draft stopped at
each floor or ceiling.
UBC, Section 1706 (a) 6;
sI. Provide dryer vent to outside. UMC, Section
1903.
ELIRICAL NATIONAL ELECTRICAL c0011
All wiring shall comply with the National
Electrical Code.
1l. Show on the plan the amperage of the
electrical service, the location of the
service panel and the location of any sub-
panels. If service is over 200 amps, submit
single line diagram; panel schedule and load
calculations.
Show location of.all electrical receptacles.
153 Electrical receptacle locations and/or spacing
is not adequate in ALL. iJEbJ £-OOfl$.
G
mow at least one convenience outlet other
than outlets for laundry, etc., outdoors, in
garages and basements. NEC, Art. 210-52.
155. Note convenience outlets in bathrooms, kitchen
counter top(s) within 6 feet of the kitchen
sink, outdoors • and in earaees and basements
(other than for laundry and similar equipment)'
shall be GFI protected. NEC, Art. 210-8.
15k. Note electrical system ground to be provided
per NEC, Art. 250-81.
PLZP(BThG (UNTP04 PLThG COE)
l4. Show water heater size, type and location on
I plans. UPC, Section 1301.
Show source for providing combustion air to I fuel burning water heater. If wall openings
in an enclosure are used, at least one-half of
the required opening area shall extend into
the upper twelve inches of the enclosure and
one-half within the lower twelve inches. UPC,
Section 1307.
Fuel combustion water heater shall not be
installed in bath or bedroom or in a closet
opening into bath or bedroom. .UPC, Section
1309.
l69'. Provide adequate barrier to protect water
f heater from vehicle damage. An 18" platform
for the water heater does not satisfy this
requirement. UPC, Section 1310.
Show T and P valve on water heater and show [ route of discharge line to exterior.
UPC, Section 1007 (e).
/19/90 9
12. Show that water heater is adequately braced to
resist seismic forces, when not connected by
rigid pipe. UHC Section 504(d).
16,h. Show shower stall can accommodate a 30" circle
and has a minimum floor area of 1,024 sq. in.
UPC 909 (d).
144. Provide clothes washer hook-up for each unit.
Title 24, Part 3.
WISE ThSULATION (DUPLEXES)
it
. Show details of duplex common (party) walls and
floor/ceiling assemblies to achieve a Sound
Transmission Class (STC) rating in walls of 50
decibels and an Impact Insulation Class (IIC)
rating on floor/ceiling of 50 decibels.
Title 24.
Show how penetrations of assemblies for piping,
electrical devices, recessed cabinets,
bathtubs, soffits, or heating ventilating, or
exhaust ducts shall be sealed, lined, or
insulated to maintain required sound
transmission rating. Title 24.
Provide insulation in walls and ceiling to
achieve STC of 50 between garage and living
area if garage use is not controlled by
resident. Title. 24.
ENERGY CONSERVATION
l. Provide plans, calculations and worksheets to 1 show compliance with current energy standards.
]4. The regulations require a properly completed
( and properly signed Form CF-1R to be either
imprinted on the plans, taped to the plans or
"sticky backed" on the plans, to allow the
building inspector to readily compare the
actual construction with the requirements of
the approved energy design.
ljO. All energy items shown on the plans must be in ' agreement with the information shown on the
properly completed Form CF-1R.
171. Specify on the building plans all of the
mandatory energy conservation requirements as
listed on the enclosure titled, "Mandatory
EnerRv Conservation Requirements".
l2. Show the make, model and efficiency of the
space heating (or cooling) system and provide
heat loss calculations if the output exceeds
45,000 BTU/Hr.
S
For room additions, show that the glazing area
of the addition does not exceed 16% of the
newly-conditioned floor area, plus glazing
removed or relocated due to the addition.
171&. Provide fluorescent general lighting in
I kitchen(s) per CAC, Title 24, 2-5352(J).
CARLSBAD S.F.D. & DUPLIK SUPPLMM
17b. Energy conservation design should be for Zone
7.
46. Floor drains must have auto-prime (city
policy).
177. Note exhaust fans cannot be ductless type
(city policy).
1/8. New residential units must be pre-plumbed for
( future solar water heating. Note "two roof
jacks must be installed" where the water
heater is in the one story garage and directly
below the most south facing roof (City
Ordinance No. 8093).
1719. Note "two 3/4" copper pipes must be installed
I to the most convenient future solar panel
location when the water heater is not in a one
story garage and is not directly below the
most south facing roof. (City Ordinance No.
8093).
18/). All piping for present or future solar water
/ heating must be insulated when in areas that
are not heated or cooled by mechanical means
(city policy).
i4. Incorporate the waterproofing details, on the
attached Policy 80-8, where interior living
space occurs below grade at the masonry
wall(s).
112. Show on the Title Sheet on the plans, the
information required by the attached
Developmental Services Sheet 112383.
1*3. All new residential buildings, including
( additions, require a soils report. Please
submit two copies. Exception: If a room
addition is limited to one story and 1000 sq.
ft. in area, then a soils report is not
required. Esgil Corporation will advise the
City to place their soils notice stamp on the
plans.
14. Heavy timber framing, minimum 6" x 10" beams
and minimum 8" x 8" post, for the structural
beam and column supporting the fire separation
between the garage and living area above, is
acceptable if shown on the plans. (city
policy).
2/26/90 10
Enclosures:
1ai4. All structures require a Class B roof covering, I except room additions. If a room addition
covers all of the existing building (2nd story
addition), then the above exception doesn't
apply.
16. City Ordinance 9792 requires two parking
spaces/unit with clear area of 20'x20' i.e. no
washing machines, etc. Show compliance.
i47. All chimneys attached to any appliance or
fireplace that burns solid fuel shall be
equipped with an approved spark arrester. The
net free area of the spark arrester shall be
not less than four- times the net free ara of
the outlet of the chimney. The spark arrester
screen shall have heat and corrosion resistance
equivalent to 12 gauge wire, 19 gauge
galvanized wire or 24 gauge stainless steel.
Openings shall not permit the passage of
spheres having a diameter larger than 1/2-inch
and shall not block the passage of spheres
having a diameter of less than 3/8-inch.
MISCELLANEOUS
148. Please see additional corrections, or remarks,
on the following page.
To speed up the recheck process, note on this
list (or a copy) where each correction item has
been addressed, i.e., plan sheet, note or
detail number, calculation page, etc.
Please indicate here if any changes have been
made to the plans that are not a result of
corrections from this list. If there are other
changes, please briefly describe them and where
they are located in the plans.
Have changes been made to the plans not
resulting from this correction list? Please
check.
Yes No
The City of Carlsbad has contracted with Esgil
Corporation located at 9320 Chesapeake Drive, Suite
208, San Diego, California 92123; telephone number
619/560-1468, to perform the plan check for your
project. If you have any questions regarding these
plan check items, please contact___________________
at Esgil Corporation. If you have any questions
regarding City Building permit procedures, please
contact Carter Darnell at the City of Carlsbad, 2075
Las Palmas Dr., telephone 619/438-1161.
Thank you.
2/14/90 11
.Is,&sIJ.) WIEM JOB SPECIFICATION ii•_.t'.I)c).
All heating, ventilating, air conditioning, and water heating equipment shall meet all of the
requirements of the Appliance Efficiency Standards and shall be certified by the California Energy
Commission.
A two stage thermostat, which controls the supplementary heat on its second stage, shall be
provided for-heat pumps.
Thermostats shall be equipped with an automatic setback, which the building occupant can program to
automatically set back the therniost.at twice in 24 hours.
Equipment which requires preventive maintenance to maintain efficient operation shall be furnished
with complete necessary maintenance information.
All gas-fired fan type central furnaces, gas-fired fan type wall furnaces, and cooking appliances
shall be equipped with an intermittent ignition device.
All fan systems exhausting air to the outside shall be provided with backdraft dampers.
All transverse duct, plenum, and fitting joints shall be sealed with pressure sensitive tape or
mastic to prevent air loss and shalrbe insulated to conform to the provisions of Section 1005 of
the UHC, 1982 Edition.
A vapor barrier is required in climate zone 1, 14, and 16.
All manufactured windows and sliding glass doors shall meet the 1972 ANSI air infiltration
standards and shall be certified and labeled.
All swinging doors and windows leading to unconditioned areas shall be fully weather-stripped.
Storage type water heaters and storage and backup tanks for solar systems shall be externally
wrapped with R-12 insulation or greater.
The five feet of pipe closest to the water heater, if outside conditioned space, shall be insulated
with a minimum of R-3. Steam and steam condensation return piping and recirculating hot water
piping outside the building envelope shall be insulated in accordance with 120-1406(d).
Lamps used in luminaries for general lighting in kitchens and bathrooms shall have an efficiency of
not less than 25 lumens per watt.
Showerheads and faucets shall be equipped with flow restrictors as outlined in the appliance
efficiency standards and shall be certified to the Energy Commission.
Masonry and factory-built fireplaces on exterior walls, shall be equipped with tight-fitting
closeable metal or glass doors covering the entire opening of the firebox; a combustion air intake
equipped with a readily accessible, operable, and tight fitting damper to draw air from the outside
of the building; and a tight fitting flue damper with a readily accessible control.
Insultion used shall comply with California Quality Standards.
The insulation installer shall post a signed certificate... Section. 276.. Insulation Certificate
(All Occupancies). Alter installing insulation, the installer shall post in a conspicuous location
in the building a certificate signed by the installer and the builder stating that the installation
conforms the requirements of Title 24, Part 2, Chapter 2-53, and that the materials installed
conform with the requirements of Title 20, Chapter 2, Subchapter 4, Article 3. The certificate
shall state the manufacturer's name and material identification, the installed "R" value, and (in
applications of loose fill insulation) the minimum installed weight per square foot consistent with
the manufacturer's labeled density for the desired "R" value.
For infiltration control all openings and penetrations must be caulked and sealed, such as around
windows, at sole plates, and openings f or utility pipes and wires.
Form EQi 3/5/86
.4 44ø,
Date _____ Jurisdiction CARLSBAD
Prepared byt o Bldg. Dept.
________
VALUATION_AND_ PLAN-CHECK _FEE (J Esgil
PLAN CHECK NO._ 10-c'32
BUILDING ADDRESS i1)Jp.oe-S7:.
APPLICANT/CONTACT -jg4iijj PHONE NO. 5?9V5.
BUILDING OCCUPANCY _ DESIGNER PHONE____________
TYPE OF CONSTRUCTION il,.) CONTRACTOR PHONE___________
BUILDING PORTION BUILDING AREA VALUATION
MULTIPLIER
VALUE
6/6 0 ii3.
L4i7)
-
Air Conditioning
Commercial -
Residential
Res. or Comm.
- Fire Sprinklers
Total Value •
_______________ • _________ 31_3'oi
Buildirij Permit FeeS
Plan Check Fee
COMMENTSt • . •.
- SHEET /_OF / 12/87
City of Carlsbad
August 23, 1990
Steven M. Boshard
Jennifer E. Boshard
2741 Monroe Street
Carlsbad, CA 92008
A recent inspection was performed at the above address in
accordance with the requirements of Building Permit # CB00432. The
Building Inspector left a correction notice at the site during the
inspection. A copy of the correction notice is inclosed with this
letter.
This matter was originally a violation handled by this office and
has not yet been fully corrected. The correction notice required
that a hood vent and gas piping for an additional kitchen be
removed. This letter is to inform you that you are still in
violation of Carlsbad Municipal Code, Section. 18.04.010,
construction without a valid building permit or approval. The
specific construction is that of the kitchen type installation not
under the permit mentioned above. This is the hood vent and gas
line installed without proper approval or permit. A permit for an
additional kitchen can not be issued due to the zoning limitations
on the R-1 property. To correct the violation you must remove the
hood vent and gas line addressed by the correction notice issued on
7/6/90.
You have until September 13, 1990 by which to remove the violation
and have an inspection performed by the Building Department to
verify compliance. You may request an inspection by Senior Building
Inspector Pat Kelley by contacting his office at 438-3550. If you
fail to comply this office will take further legal action to gain
compliance.
2075 Las Palmas Drive • Carlsbad, California 92009 • (619) 438-1161
Boshard
August 23, 1990
Page 2
Contact the undersigned at 438-1162 if you have any questions
regarding this letter.
MICHAEL A. HARRINGTON
Code Enforcement Officer
c: Pat Kelley
Pete Dreibelbis
City Attorney
Building Permit File/
mah
Enclosure
CORRECTION NOTICE
ADDRESS: 27'I
APPROVED PLANS SHALL BE ON JOB SITE
//
BUILDING t:iiotJ_7#/. 4
- 0 FOUNDATION
O REINFORCING STEEL 7 ,f a MASONRY GROUT•GUNITE
0 FLOOR AND CEILING FRAME
O SHEATHiNG.
0 FRAME
O EXTERIOR LATH . tL)
INSULATION
INTERIOR LATH OR DRYWALL
S..'
. PLUMBING .............., ,,, iiie- . c'1 '-•
0 UNDERGROUND PLUMBING
0 UNDERGROUND WATER
0 ROUGH PLUMBING
O TOP OUT PLUMBING
O SEWER AND PLJCO.
0 TUB OR SHOWER PAN
O GAS TEST
O WATER HEATER
-----.. -1
•.. f.
1
ELECTRICAL
O TEMPORARY SERVICE
O ELECTRIC UNDERGROUND
O ROUGH ELECTRIC
O POOL BONDING
O ELECTRIC SERVICE
C3 LIFER GROUND
G.F.I.
O SMOKE DETECTOR
MISCELLANEOUS
O PLENUM AND DUCTS
O COMBUSTION AIR
CONDITIONED AIR SYSTEMS
OSOLAR . .
O GRADING
OPOOL. •..,
O PATIO - ....-- - .-. .1-.•_ -..________ -- ••-
O SIGN
O OTHER
TIME: • /
DATE: /
INSPECTOR .
CITY OF CARLSBAD
BUILDING INSPECTION DEPARTMENT
PHONE-438-3550
I. . . Note: Final Inspection Required
CERTIFICATION OF COMPLIANCE
CITY OF CARLSBAD Plan Check No.
DEVELOPMENT PROCESSING SERVICES DIVISION
2075 LAS PALMAS CARLSBAD, CA 92009
(619) 438-1161
This form shall be used to determine the amount of school fees for a project and to verify
that the project applicant has complied with the school fee requirements. No building
permits for the projects shall be issued until the certification is signed by the
appropriate school district and returned to the City of Carlsbad Building Department.
SCHOOL DISTRICT:
"Carlsbad Unified
801 Pine Avenue
Carlsbad, CA 92009 (434-0610)
Encinitas Union Elementary
189 Union Street
Encinitas, CA 92024 (944-4306)
San Marcos Unified
270 West San Marcos Blvd.
San Marcos, CA 92069 (744-4776)
San Dieguito Union High School
710 Encinitas Boulevard
Encinitas, CA 92024 (753-6491)
Project Applicant: ________________ APN: /5' -3 V -0
Project Address: c7 c/ L.-i'O E
RESIDENTIAL: SQ. SQ. FT. of living area 615~ Number of dwelling units
SQ. FT. of covered area SQ. FT. of garage area
COMMERCIAL! INDUSTRIAL: SQ. FT. AREA
Prepared By I$?.4A&k1 QQ_4" Date
FEE CERTIFICATION
(To be completed by the School District)
Applicant has complied with fee requirement under Government Code 53080
Project is subject to an existing fee agreement
Project is exempt from Government Code 53080
Final Map approval and construction started before September 1, 1986.
(other school fees paid)
Other
Residential Fee Levied: $qlO based on sq. ft.@ L
Comm/Indust Fee Levied: $ based on sq. ft.@
4 Ii!) I ILL
Sc1ool jDitict Official Title Date
AB 2926 and SB 201 fees are capped at $1.58 per square foot for residential.
AB 2926 is capped at $26 per square foot for commercial/industrial.