Loading...
HomeMy WebLinkAbout2744 CARLSBAD BLVD; 104; CB050362; PermitCity of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Commercial/Industrial Permit Permit No: CB050362 Building Inspection Request Line (760) 602-2725 Job Address: Permit Type: Parcel No: Valuation: Occupancy Group: Project Title: Applicant: 2744 CARLSBAD BL CBAD St: 104 Tl Sub Type: COMM 2031722700 Lot#: 0 $51,770.00 Construction Type: V1 Reference #: PERFONTAINE SALON 1670 SFTl SHELL TO SALON COMBINE SUITES 104 & 106 Owner: Status: Applied: Entered By: Plan Approved: Issued: Inspect Area: Plan Check*: ISSUED 02/07/2005 KG 04/26/2005 04/26/2005 ANASTASI DEVELOPMENT CO L L C 1200 AVIATION BLVD #203 REDONDO BEACH CA 90278 Building Permit Add'l Building Permit Fee Plan Check Add'l Plan Check Fee Plan Check Discount Strong Motion Fee Park Fee LFM Fee Bridge Fee BTD #2 Fee BTD #3 Fee Renewal Fee Add'l Renewal Fee Other Building Fee Pot. Water Con. Fee Meter Size Add'l Pot. Water Con. Fee Reel. Water Con. Fee $361.76 Meter Size $0.00 Add'l Reel. Water Con. Fee $235.14 Meter Fee $0.00 SDCWA Fee $0.00 CFD Payoff Fee $10.87 PFF $0.00 PFF (CFD Fund) $0.00 License Tax $0.00 License Tax {CFD Fund) $0.00 Traffic Impact Fee $0.00 Traffic Impact (CFD Fund) $0.00 PLUMBING TOTAL $0.00 ELECTRICAL TOTAL $0.00 MECHANICAL TOTAL SO.00 Master Drainage Fee Sewer Fee $0.00 Redev Parking Fee SO.00 Additional Fees TOTAL PERMIT FEES $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $91.00 $60.00 $30.50 $0.00 $0.00 $0.00 $0.00 $789.27 Total Fees:$789.27 Total Payments To Date:$235.14 Balance Due:$554.13 6796 04/26/05 0002 01 02 CGP 554-13 Inspector: FINAL APPROVAL Date: _Z NOTICE: Please take NOTICE that approval of your project includes the Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as lees/exactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar toihis. or as to which the statute of limitations has previously otherwise expired. PERMIT APPLICATION CITY OF CARLSBAD BUILDING DEPARTMENT 1635 Faraday Ave., Carlsbad CA 92008 Address (include Bldg/Suite #) FOR OFFICE USE ONLY PLAN CHECK NO.Cftl5"ff ^^ EST. VAL. 57 "7 7 Plan Ck. Deposit Validated By Date . l* - Business IJrame (at trlis address) Legal Total # of units 14 (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law [Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code] or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant IB a civil penalty of nnt more than five hundred dollars [$500]). t Name State License # Addr*ss License Class - \ {/ State/Zip City Business License #. . Telephone # W°S esigner Name State License # Address City State/Zip Telephone # orkers' Compensation Declaration: I hereby affirm under penalty of perjury one of the following declarations: D I have and will maintain a certificate of consent to setf-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain worker's compensation, as required by Section 3700 of the labor Code, for the performance of the work for which this permit is issued. My worker's compensationjnsyrancg career ^pd -policy fu^m be r are: X-_* /"5 il * '•" 1 'Insurance Company _.Policy No. o the aor ode, or te perorman /X-_*^ /"5 il O *s '^•"XlM . COO rV"\ p(Q " ^-^xoioiration Dale (THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS [$100} OR LESS) D CERTIFICATE OF EXEMPTION: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to .become subject to the Workers' Compensation Laws of c4lif/lnia. \ /WARNING: Failure to secure wojjrfffe' compensation &vtfa\B is unlawful, and shall subject an employer to criminal penalties and civil fines up|to one f undred thousand dollarsf $100,000),in addltionXwma^slWiMmpeiyajHn, barrages are provided for in Section 3706 of the Labor Code, interest and attorney's fees, j NATURE ^S///IJA/\\Jl lAl __ DATE__Hj "<™.^p^ •lT"l«tS ? I hereby affirm that I am exempt from the Contractor' Aicense Law for the following reason: D I, as owner of the property or my employees with wages as their sole compensation, will d the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). D I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). D I am exempt under Section Business and Professions Code for this reason: 1. I personally plan to provide the major labor and materials for construction of the proposed property improvement. D YES D NO 2. I (have/have not) signed an application for a building permit for the proposed work. 3. I have contracted with the following person (firm) to provide the proposed construction (include name / address / phone number / contractors license number): 4. I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone number / /ontractors license number): 5. I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone number / type of work): PROPERTY OWNER SIGNATURE.DATE WHITE: File YELLOW: Applicant PINK: Finance PERMIT APPLICATION CITY OF CARLSBAD BUILDING DEPARTMENT 1635 Faraday Ave., Carlsbad CA 92008 Page 2 of 2 Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration for or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? D YES D NO Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? D YES D NO Is the facility to be constructed within 1,000 feet of the ouler boundary of a school site? D YES P NO IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097(1) Civil Code) LENDER'S NAME LENDER'S ADDRESS I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all City ordinances and State laws relating to building construction. I hereby authorize representatives of the City of Carlsbad lo enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGEMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: An OSHA permit is required for excavations of 5'0" deep and demolition or construction of structures over 3 stories in height. EXPIRATION: Every permit issued by the building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of UK) days (Section 106.<U*lai{orm Buildyig Code). APPLICANT'S SIGNATURE DATE WHITE: File YELLOW: Applicant PINK: Finance Inspection List Permit#: CB050362 Type: Tl Date Inspection Item COMM Inspector Act 07/26/2005 89 Final Combo PY 07/26/2005 89 Final Combo 07/25/2005 89 Final Combo 07/25/2005 89 Final Combo PY 07/22/2005 89 Final Combo 07/22/2005 89 Final Combo JM 07/19/200539 Final Electrical PY 07/19/200539 Final Electrical 07/07/2005 14 Frame/Ste el/Bo Itlng/W el din PY 07/06/2005 21 Underground/Under Floor BN 06/14/2005 17 Interior Lath/Drywall PY 06/08/2005 14 Frame/Steel/Bolting/Weldin PY 06/08/2005 24 RoughfTopout PY 06/08/2005 34 Rough Electric PY 06/08/2005 44 Rough/Ducts/Dampers PY 06/07/2005 84 Rough Combo PC 05/12/2005 14 Frame/Steel/Bolting/Weldin PY 05/12/200534 Rough Electric PY 05/02/2005 21 Underground/Under Floor PY AP Rl Rl CA Rl CA PA Rl PA AP AP AP AP AP PA CA AP AP AP PERFONTAINE SALON 1670 SF Tl SHELL TO SALON COMBINE SUITES 104 Comments PM PLEASE PM PLEASE by don EMR METER REL FLOOR DRAINS PER OFFICE SUB FLOOR Wednesday, July 27, 2005 Page 1 of 1 City of Carlsbad Bldg Inspection Request For: 07/26/2005 Permit* CB050362 Title: PERFONTAINE SALON 1670 SFTI Description: SHELL TO SALON COMBINE SUITES 104 & 106 Inspector Assignment: PY Sub Type: COMM 2744 CARLSBAD BL 104 Lot 0 Type: Tl Job Address: Suite: Location: ONTRACTOR SUMMIT DEVELOPMENT Owner: ANASTASI DEVELOPMENT CO L L C Remarks: PM PLEASE Phone: 6192470221 Inspector: Total Time: CD Description 19 Final Structural 29 Final Plumbing 39 Final Electrical 49 Final Mechanical Requested By; DON Entered By: CHRISTINE Comment Associated PCRs/CVs Inspection History Date Description 07/22/2005 89 Final Combo 07/19/2005 39 Final Electrical 07/07/2005 14 Frame/Steel/Bolting/Welding 07/06/2005 21 Underground/Under Floor 06/14/2005 17 Interior Lath/Drywall 06/08/2005 14 Frame/Steol/Bolting/Welding 06/08/2005 24 Rough/Topout 06/08/2005 34 Rough Electric 06/08/2005 44 Rough/Ducts/Dampers 06/07/2005 84 Rough Combo 05/12/2005 14 Frame/Steel/Bolting/Welding 05/12/2005 34 Rough Electric 05/02/2005 21 Underground/Under Floor Act Insp Comments CA JM by don PA PY EMR PA PY AP BN FLOOR DRAINS AP PY AP PY AP PY AP PY PA PY CA PC PER OFFICE AP PY SUB FLOOR AP PY AP PY EsGil Corporation In Partnership witfi government for (Bulging Safety DATE: April 25, 2005 Q APPLICANT ^ar JURIS. JURISDICTION: Carlsbad a PLAN REVIEWER a FILE PLAN CHECK NO.: O5-362 SET: IV PROJECT ADDRESS: 2744 Carlsbad Blvd. #104 PROJECT NAME: (TI) (Village by The Sea) (Hair Salon) XI The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: Esgil Corporation staff did not advise the applicant that the plan check has been completed. 2S] Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Mr. Smyer Telephone #: In Person Date contacted: (by: ) Fax #: Mail Telephone Fax In Person REMARKS: Design to deliver plans to City. By: Bill Elizarraras Enclosures: Esgil Corporation D GA D MB D EJ D PC LOG trnsmtl.dot 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 * (858)560-1468 * Fax (858) 560-1576 EsGil Corporation In <Partnersfiip with government for Quitting Safety DATE: AprU 20, 2005 Q APPLICANT JURISDICTION: Carlsbad a PLAN REVIEWER a FILE PLAN CHECK NO.: 05-362 SET: III PROJECT ADDRESS: 2744 Carlsbad Blvd. #104 PROJECT NAME: (TI) Retail (Village by The Sea) The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. X] The applicant's copy of the check list has been sent to: Smyer Architecture 337 S. Cedros Ave. Ste. F, Solana Beach, CA. 92008 Esgil Corporation staff did not advise the applicant that the plan check has been completed. Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Smyer Architecture / / Telephone #: 858-755-4731 Date contacted: y/Z/^by^fc9 ff Fax #: 858-755-6594 Mail ^Telephone V^rax l/ln Person REMARKS: By: Bill Elizarraras Enclosures: Esgil Corporation D GA D MB D EJ D PC 4/15/05 trnsmtl.dot 9320 Chesapeake Drive, Suite 208 * San Diego, California 92123 * (858)560-1468 + Fax (858) 560-1576 Carlsbad 05-362 April 2O, 2005 RECHECK PLAN CORRECTION LIST JURISDICTION: Carlsbad PLAN CHECK NO.: 05-362 PROJECT ADDRESS: 2744 Carlsbad Blvd. #104SET: III DATE PLAN RECEIVED BY DATE RECHECK COMPLETED: ESGIL CORPORATION: 4/15/05 AprU 20, 2005 REVIEWED BY: Bill Elizarraras FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and disabled access. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department or other departments. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. A. Please make all corrections on the original tracings and submit new complete sets of prints to: THE JURISDICTION'S BUILDING DEPARTMENT. B. To facilitate rechecking, please identify, next to each item, the sheet of the plans upon which each correction on this sheet has been made and return this sheet with the revised plans. C. The following items have not been resolved from the previous plan reviews. The original correction number has been given for your reference. In case you did not keep a copy of the prior correction list, we have enclosed those pages containing the outstanding corrections. Please contact me if you have any questions regarding these items. D. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located on the plans. Have changes been made not resulting from this list? PYes Q No Carlsbad 05-362 April 20, 2005 * The following corrections are from the original deficiency list, and were either not addressed or a result of new changes. 1. Please make all corrections on the original tracings, as requested in the correction list. Submit two sets of plans for residential projects. For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. 2. Each sheet of the plans must be signed by the person responsible for their preparation, even though there are no structural changes. Business and Professions Code. 3. Provide mechanical plans, showing existing and proposed HVAC equipment, ducts and access to equipment. Note the following on the plans: * On the mechanical plans clearly show the limits of ceiling space used as duct or plenum, Then address the following on the plans: a) Clearly show that all material exposed within the plenum complies with UMC Section 601.4. "Materials shall have a mold-, humidity-, and erosion-resistant face that meets the requirements of UL 181." Clarify limits of the return air. b) Clothes-dryer moisture-exhaust ducts shall not extend into or through ducts or plenums. UMC Section 504.3.1. Provide the Mfg. specification sheets for the booster fan (The location is not standard @ the end of the run) c) Detail the water heater flue vent to the exterior (Shaft thru two stories above?) Provide the Mfg. specification sheets for the PVC booster fan. Provide shaft details for same. d) Detail the flue for the second FAU unit (Over restroom area). e) Where is the fresh air for both FAU units? f) The Title 24 document different heating units than those specified on the plans, please clarify? 4. Provide complete plumbing plans, including: a) Complete drain, waste and vent plans. Show the following on the plans. b) Provide cleanouts for branches exceeding 5'-0" from main line. c) Please see attached loop / island vent schematics and correct on the plans. d) Each loop / island vent should have it's own vent. e) Provide waste lines for the loop/ island vents and color sink to the main. To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Bill Elizarraras at Esgil Corporation. Thank you. UPC ILLUSTRATED TRAINING MANUAL Special Venting for Island Fixtures Traps for island sinks and similar equipment shall be roughed in above the floor and may be vented by extending the vent as high as possible, but not less than drain board height. The vent is then returned downward and connected to the horizontal sink drain immediately downstream from the vertical fixture drain. Figure 9-25 illustrates the construction of the completed island venting system. The returned vent shall be connected to the horizontal drain through a wye branch fitting, (see "b" in Figure 9-25) and shall in addition be provided with a foot vent taken off the vertical fixture vent by means of a wye branch fitting immediately below the floor. This foot vent extends to the nearest partition and thence through the roof to the open air, or may be connected to other vents at a point not less than (6) inches (152.4 mm) above the flood level rim of the fixture served, (See Figure 9-25.) Drainage fittings shall be used on all parts of the vent below the floor line. This includes fittings noted as a, b, c, and d in the illustrations. The foot vent shall maintain a minimum slope of one-quarter inch per foot back to the drain. The return bend used under the drainboard shall be a one piece fitting, or an assembly of a 45° (0.79 rad), a 90° (1.6 rad), and a 45° (0.79 rad) elbow in the order named. Pipe sizing shall be as elsewhere required in the Code. Figure 9-25 shows the minimum pipe sizes required. Special venting for island fixtures is a method for venting a fixture in an isolated location where vent pipes installed as normally required in UPC Chapter 9 would not be practical. The specific method for developing Figure 9-25 was closely detailed and explained because too often plumbers and inspectors allow incomplete island venting to be installed. The installation of the required foot vent with its termination above the roof or properly connected to other vents is inseparable to the completed system. Figure 9-25 is the Code- accepted method, and includes all of the necessary elements. DRAINBOARD VERTICAL FIXTURE - FLOOR DRAIN NO FIXTURES UPSTREAM VENT THROUGH ROOF OR CONNECT TO OTHER VENTS NEAREST PARTITION *• PER FOOT GRADE C.O. I "a" "b" A, B AND C ARE Y-BRANCH FITTINGS Figure 9-25 Special Venting for Island Fixtures 270 EsGil Corporation In (partnership witK government for <Bui£tfing Safety DATE: AprU 7, 2005 a_ARELJC_ANT JURISDICTION: Carlsbad Q PLAN REVIEWER a FILE PLAN CHECK NO.: O5-362 SET: II PROJECT ADDRESS: 2744 Carlsbad Blvd. #104 PROJECT NAME: (TI) Retail (Village by The Sea) The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. XI The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. XI The applicant's copy of the check list has been sent to: Smyer Architecture 337 S. Cedros Ave. Ste. F, Solana Beach, CA. 92008 Esgil Corporation staff did not advise the applicant that the plan check has been completed. XI Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Smyer Architecture Telephone #: 858-755-4731 Date contacted: ^/7/^(b\/^) Fax #: 858-755-6594 Mail^i elephone Fax ^m Person REMARKS: By: Bill Elizarraras Enclosures: Esgil Corporation D GA D MB D EJ D PC 3/31/05 tmsmtl.dot 9320 Chesapeake Drive, Suite 208 4 San Diego, California 92123 4 (858)560-1468 + Fax (858) 560-1576 Carlsbad 05-362 April 7, 2005 RECHECK PLAN CORRECTION LIST JURISDICTION: Carlsbad PLAN CHECK NO.: 05-362 PROJECT ADDRESS: 2744 Carlsbad Blvd. #104SET: II DATE PLAN RECEIVED BY DATE RECHECK COMPLETED: ESGIL CORPORATION: 3/31/05 April 7, 2005 REVIEWED BY: Bill Elizarraras FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and disabled access. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department or other departments. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. A. Please make all corrections on the original tracings and submit new complete sets of prints to: THE JURISDICTION'S BUILDING DEPARTMENT. B. To facilitate rechecking, please identify, next to each item, the sheet of the plans upon which each correction on this sheet has been made and return this sheet with the revised plans. C. The following items have not been resolved from the previous plan reviews. The original correction number has been given for your reference. In case you did not keep a copy of the prior correction list, we have enclosed those pages containing the outstanding corrections. Please contact me if you have any questions regarding these items. D. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located on the plans. Have changes been made not resulting from this list? QYes QNo Carlsbad 05-362 April 7, 2005 * The following corrections are from the original deficiency list, and were either not addressed or a result of new changes. • PLANS 1. Please make all corrections on the original tracings, as requested in the correction list. Submit two sets of plans for residential projects. For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. 2. Each sheet of the plans must be signed by the person responsible for their preparation, even though there are no structural changes. Business and Professions Code. 3. Provide a section view of all new interior partitions. Show: a) Method of attaching top and bottom plates to structure. (NOTE: Top of partition must be secured to roof or floor framing, unless suspended ceiling has been designed for partition lateral load). The proposed wall to ceiling grid attachment detail is not acceptable for this type of application, unless the grid system is listed for lateral wall loading. Use an alternative application or provide Mfg. specification for the submitted details. 4. Even though one exit is required for this project both doors must meet the both code and handicap requirements. The primary door @ the receptionist area is ok but the second door has a step? Use an alternative application or provide a ramp if keeping this door. 5. Provide mechanical plans, showing existing and proposed HVAC equipment, ducts and access to equipment. Note the following on the plans: "* On the mechanical plans clearly show the limits of ceiling space used as duct or plenum. Then address the following on the plans: a) Clearly show that all material exposed within the plenum complies with UMC Section 601.4. "Materials shall have a mold-, humidity-, and erosion-resistant face that meets the requirements of UL 181." b) Clothes-dryer moisture-exhaust ducts shall not extend into or through ducts or plenums. UMC Section 504.3.1. Also detail the dryer vent exhaust duct route to the exterior. c) Detail the water heater flue vent to the exterior (Shaft thru two stories above?) Carlsbad 05-362 April 7, 2005 6. Provide complete plumbing plans, including: a) Complete drain, waste and vent plans. Show the following on the plans. b) Floor drain and venting @ utility closet. c) Specify trap primary for same. d) Detail the foot vent for the color bar sink. e) Show a vent for the washer. f) Provide cleanouts for branches exceeding 5'-0" from main line. g) Show the T & P for the water heater and area of discharge. 7. Provide a detail for the wood floor transition to existing concrete (Where they butt up). 8. Show on the plans that the receptionist desk/ counter will meet the Handicap height requirements (28" minimum - 34" max height). 9. WIRING METHODS: AC Cable is not allowed in A, B, E, H, and I occupancies. NM cable is restricted (without City approval) to one and two family dwellings. Note on plans that an equipment ground conductor is to be installed in all flexible conduits. Show this note on the plans. To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please indicate: Yes Q No Q The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Bill Elizarraras at Esgil Corporation. Thank you. EsGil Corporation In Partnership witfi government for Quitting Safety DATE: February 18, 2005 Q APPLICANT JURISDICTION: Carlsbad Q PLAN REVIEWER Q FILE PLAN CHECK NO.: 05-362 SET: I PROJECT ADDRESS: 2744 Carlsbad Blvd. #104 PROJECT NAME: (TI) Retail (Village by The Sea) The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. X] The applicant's copy of the check list has been sent to: Smyer Architecture 337 S. Cedros Ave. Ste. F, Solana Beach, CA. 92008 Esgil Corporation staff did not advise the applicant that the plan check has been completed. Ai Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Smyer Architecture (VvorJrJe) Telephone #: 858-755-4731 Date contacted: A)nJo5~ (by:v^ ) Fax #: 858-755-6594 • Mail -^Telephone Fax ^In Person REMARKS: By: Bill Elizarraras Enclosures: Esgil Corporation D GA D MB D EJ D PC 2/10/05 tmsmtl.dot 9320 Chesapeake Drive, Suite 208 4 San Diego, California 92123 4 (858) 560-1468 4 Fax (858) 560-1576 Carlsbad 05-362 February 18, 2005 PLAN REVIEW CORRECTION LIST TENANT IMPROVEMENTS PLAN CHECK NO.: 05-362 OCCUPANCY: M TYPE OF CONSTRUCTION: V-1HR ALLOWABLE FLOOR AREA: SPRINKLERS?: N REMARKS: DATE PLANS RECEIVED BY JURISDICTION: DATE INITIAL PLAN REVIEW COMPLETED: February 18, 2005 JURISDICTION: Carlsbad USE: Retail ACTUAL AREA: 1670 STORIES: ? HEIGHT: ? OCCUPANT LOAD: 56 DATE PLANS RECEIVED BY ESGIL CORPORATION: 2/10/05 PLAN REVIEWER: Bill Elizarraras FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Code sections cited are based on the 1997 UBC. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans. TENANT IMPROVEMENTS WITHOUT SPECIFIC ENERGY DATA OR POLICY SUPPLEMENTS (1997UBC)tiforw.dot Carlsbad O5-362 February 18, 2005 • PLANS 1. Please make all corrections on the original tracings, as requested in the correction list. Submit two sets of plans for residential projects. For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. 2. Each sheet of the plans must be signed by the person responsible for their preparation, even though there are no structural changes. Business and Professions Code. 3. Provide a floor plan showing the use of all rooms or areas within the space being improved or altered. Section 106.3.3. 4. Identify all the equipment or fixtures on the plans. 5. Identify existing walls to be removed, existing walls to remain and proposed new walls. Identify bearing walls, non-bearing walls, and shear walls. 6. Provide a section view of all new interior partitions. Show: a) Type, size and spacing of studs. Indicate gauge for metal studs. Specify manufacturer and approval number or indicate "to be ICBO approved". b) Method of attaching top and bottom plates to structure. (NOTE: Top of partition must be secured to roof or floor framing, unless suspended ceiling has been designed for partition lateral load). c) Wall sheathing material and details of attachment (size and spacing of fasteners). d) Show height of partition and suspended ceiling, and height from floor to roof framing or floor framing. 7. The tenant space, new and/or existing facilities serving the remodeled area must be accessible to and functional for the physically disabled. Show the path of travel from approved Handicap parking or provide a statement certifying (Signed) that the facility meets the accessibility requirements per Title 24. 8. Exit signs are required whenever two exits are required. Show all required exit sign locations. Section 1003.2.8.2. Carlsbad 05-362 February 18, 2005 9. Submit plan showing location of all electrical panels. 10. Submit electrical panels schedules. 11. Show the location, type and size (BTU's) of all heating and cooling appliances or systems. 12. Provide mechanical plans, showing existing and proposed HVAC equipment, ducts and access to equipment. 13. Detail overflow (secondary) condensate discharge from air conditioning units that are in a ceiling space, to a readily observable location. (UMC Section 1105.12) 14. Provide complete plumbing plans, including: a) Complete drain, waste and vent plans. 15. Provide complete energy designs for the proposed changes in envelope, (lighting systems). Provide the completed LTG- forms showing energy compliance. 16. The completed and signed LTG-1 forms must be imprinted on the plans. 17. WIRING METHODS: AC Cable is not allowed in A, B, E, H, and I occupancies. NM cable is restricted (without City approval) to one and two family dwellings. Note on plans that an equipment ground conductor is to be installed in all flexible conduits. To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list If there are other changes, please briefly describe them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please indicate: Yes Q No Q The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Bill Elizarraras at Esgil Corporation. Thank you. Carlsbad 05-362 February 18, 2005 VALUATION AND PLAN CHECK FEE JURISDICTION: Carlsbad PLAN CHECK NO.: 05-362 PREPARED BY: Bill Elizarraras DATE: February 18, 2005 BUILDING ADDRESS: 2744 Carlsbad Blvd. #104 BUILDING OCCUPANCY: M/R1 TYPE OF CONSTRUCTION: V-1HR BUILDING PORTION ti Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code AREA ( Sq. Ft.) 1670 CB Valuation Multiplier Per City Value By Ordinance Reg. Mod. VALUE ($) 51,770 51,770 $352.76 1994 UBC Plan Check Fee Type of Review: LD Repetitive Fee Repeats Complete Review D Other i—i Hourly Structural Only Hour* Esgll Plan Review Fee $229.29 $197.55 Comments: Sheet 1 of 1 macvalue.doc PLANNINC/ENCINIERINC APPROVALS PERMIT NUMBER CR DATE ADDRESS RESIDENTIAL -! RESIDENTIAL ADDITfOK MINOR (< $10,000.00) TENANT IMPROVEMENT PLA3A CAMINO REAE . . b. ' - . CARLSBAD COMPANY STORES VILLAGE FAIRE COMPLETE OFFICE,BUILDING OTHER 'LANNiR DATE ENGINEER DATE l ' Carlsbad Fire Department 050362 1635 Faraday Ave. Carlsbad, CA 92008 Plan Review Requirements Category: Date of Report: 04/11/2005 Fire Prevention J60) 602-4660 Building Plan Reviewed by; Name: Address: City, State: Smyer Architecture 337 S. Cedros Ave.Suite F Solana Beach CA 92075 Plan Checker: Job Name: Village by the Sea Job Address: 2744 Carlsbad Blvd Job #; 050362 Bldg #: CB050362 Ste. or Bldg. No. D Approved The item you have submitted for review has been approved. The approval is based on plans, information and / or specifications provided in your submittal; therefore any changes to these items after this date, including field modifications, must be reviewed by this office to insure continued conformance with applicable codes and standards. Please review carefully all comments attached as failure to comply with instructions in this report can result in suspension of permit to construct or install improvements. Approved The item you have submitted for review has been approved subject to the Subject to attached conditions. The approval is based on plans, information and/or specifications provided in your submittal. Please review carefully all comments attached, as failure to comply with instructions in this report can result in suspension of permit to construct or install improvements. Please resubmit to this office the necessary plans and / or specifications required to indicate compliance with applicable codes and standards. D Incomplete The item you have submitted for review is incomplete. At this time, this office cannot adequately conduct a review to determine compliance with the applicable codes and / or standards. Please review carefully all comments attached. Please resubmit the necessary plans and / or specifications to this office for review and approval. Rpuipw 1st ,, ?nd 3rd FD Job # 050362 FD File # Dthfir Anpnr.y in Carlsbad Fire Department °50362 1635 Faraday Ave. pjre Prevention Carlsbad, CA 92008 (760) 602-4660 Plan Review Date of Report: 04/11/2005 Reviewed by: Name: Smyer Architecture Address: 3^7 ®- Cedros Ave. Suite F City, State: Solana Beach CA 92075 Plan Checker: Job Name: Village by the Sea Job Address: 2744 Carlsbad Blvd _ Ste. or Bldg. No. Fire Department would condition this approval that if in the event that it is found that the existing fire sprinkler coverage is obstructed or in any manner determined to be improper, then it shall be the responsibility of the contractor to remedy by what ever means necessary to provide for the appropriate fire sprinkler coverage. -Carlsbad Fire Department 050362 1635 Faraday Ave. Carlsbad, CA 92008 Plan Review Requirements Category: Date of Report: 02/09/2005 Fire Prevention (760) 602-4660 Building Plan Reviewed by: Name: Address: Smyer Architecture 337 S. Cedros Ave.Suite F City, State: Solana Beach CA 92075 Plan Checker: Job Name: Village by the Sea Job #: 050362 Job Address: 2744 Carlsbad Blvd i—i Approved Bldg #: CB050362 Ste. or Bldg. No. The item you have submitted for review has been approved. The approval is based on plans, information and / or specifications provided in your submittal; therefore any changes to these items after this date, including field modifications, must be reviewed by this office to insure continued conformance with applicable codes and standards. Please review carefully all comments attached as failure to comply with instructions in this report can result in suspension of permit to construct or install improvements. Approved The item you have submitted for review has been approved subject to the Subject to attached conditions. The approval is based on plans, information and/or specifications provided in your submittal. Please review carefully all comments attached, as failure to comply with instructions in this report can result in suspension of permit to construct or install improvements. Please resubmit to this office the necessary plans and / or specifications required to indicate compliance with applicable codes and standards. Incomplete The item you have submitted for review is incomplete. At this time, this office cannot adequately conduct a review to determine compliance with the applicable codes and / or standards. Please review carefully all comments attached. Please resubmit the necessary plans and / or specifications to this office for review and approval. Review FD Job # 1st 9nH 3rd 050362 FD File # Other Agency ID Requirements Category:Building Plan Requirement: Pending 05.01 Project Data Provide complete address and suite designation. Provide building construction information indicating occupancy classification, type of construction, number of stories, aggregate square footage, occupant load, and description of intended uses. NOTE TO APPLICANT: PLANS INDICATE THAT THIS IS A NONE SPRINKLED BUILDING, YOU WOULD BE ENCORAGED TO REASSESS THIS CONDITION AND REVISE PLANS IF NECESSARY. PLANS SHOULD INCLUDE TYPICAL 'FIRE DEPARTMENT1 AND 'BUILDING1 NOTES. 05.03 Floor PlanRequirement: Pending Provide a complete floor plan of building or suite. Show exiting from all areas. Indicate use or occupancy of each room including adjacent suite if applicabie. THE BLACKLINE DRAWING PROVIDED, IN PARTICULAR SHEETS M-1 AND P-1 ARE NEAR UNREADABLE PLEASE RESUBMIT LEGIBLE DRAWINGS. SHEET A-101: THE HEIGHT OF THE PROPOSED 2x4 WALLS HAS NOT BEEN PROVIDED. ARE WE TO ASSUME THEY ARE ALL FULL HEIGHT? Requirement: Pending 05.11 Knox Box Knox Box required when access to or within a structure or an area is unduly difficult because of secured openings or where immediate access is necessary for life saving or fire-fighting purposes. The Fire Department will determine the location for the key box and provide an authorized order form. OWNER/TENANT SHALL BE REQUIRED TO PROVIDE A KNOX KEY BOX FOR FIRE DEPARTMENT USE IF ONE IS NOT PRESENT. Requirement: Pending 05.16 A/S Design Sprinkler system design shall be in accordance with standards set forth by the National Fire Protection Association and UBC Standards 38-1 and 38-2. Permits are required prior to installation. Plans, specifications and calculations shall be certified by a licensed fire protection engineer or other person deemed competent by the Chief, and submitted in the name of a licensed sprinkler contractor. Warehouse buildings for which no specific use, occupant, product, activity or storage array has been identified, shall be protected by sprinkler system designed to deliver water at the rate of .45 gallons per square foot, throughout a 3000 square foot design area. FIRE DEPARTMENT WOULD ASSERT THAT AN AUTO MATIC FIRE SPRINKLER SYSTEM EXISTS IN THE SHELL BUILDING. THIS WOULD REQUIRE THE SUBMITTAL OF PLANS TO ALTER THIS SYSTEM AS PART OF THIS PROJECT. Page 1 02/09/05 TITLE 24 REPORT Title 24 Report for: Prefontaine Salon 2744 Carlsbad Blvd Carlsbad, CA 92008 Project Designer: Smyer Architecture 337 S. Cedros Ave Suite F Solana Beach, CA 92075 858-755-4731 Report Prepared By: Mark E Richards PE Emery Mechanical Engineering 6653 Cowles Mtn. Blvd. San Diego, CA92119 (619)464-5348 Job Number: 0504 4/13/2005 The EnergyPro computer program has been used to perform ti it calculations bwnn larizet in thu compliance report. This program has approval and is authorized by the California Energy Commission for use with bath the Resident! arH Nonresidontia' 2001 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC (415) 897-6400 ,Jo*> Numhar: 0504EnergyPro 3.1 By EnergySoft .- ' l/'&^Sw^ 5'1' '''' ' '•'•I-'''" L- ISSUE DATE Ol-01-aOOB . <"^ ''"':' "' "' ' ia to fcertlfy that v^ h»^ tscued lnsur*Moai CanwAttiQnpr to tfu Thi* potter!*Wet *ubj«ct to nottc« shoutd this policy.'beW» will aka flhm you 30 &•*•'- ajinc* l '. ••W"'1' '/••>•' f- ^S^#/1?'.--J'"; •'-'.'.'.'.',v.' • ' -: ..'.\IH\ ">-':!:- ;.'>'•:.V^V;->'V-></V -'V^'. vA' .;••", ROI^ERAGE IMC