Loading...
HomeMy WebLinkAbout2744 CARLSBAD BLVD; 118; CB051293; Permit06-08-2005 City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Commercial/Industrial Permit Permit No: CB051293 Building Inspection Request Line (760) 602-2725 Job Address: Permit Type: Parcel No: Valuation: Occupancy Group: Project Title: 2744 CARLSBAD BL CBAD St: 118 Tl Sub Type: 2031722700 Lot #: $31,310.00 Construction Type: Reference #: TAN BY THE SEA 1010 SF Tl VANILLIA SHELL TO TAMING SALON COMM 0 NEW Applicant: SHANTHI LACKEY SUITE H 4008AGUILA 92008 822-9497 Status: Applied: Entered By: Plan Approved: Issued: Inspect Area: Plan Check*: ISSUED 04/06/2005 SB 06/08/2005 06/08/2005 Owner: ANASTASI DEVELOPMENT CO L L C 1200 AVIATION BLVD #203 REDONDO BEACH CA 90278 Building Permit Add'l Building Permit Fee Plan Check Add'l Plan Check Fee Plan Check Discount Strong Motion Fee Park Fee LFM Fee Bridge Fee BTD #2 Fee BTD #3 Fee Renewal Fee Add'l Renewal Fee Other Building Fee Pot. Water Con. Fee Meter Size Add'l Pot. Water Con. Fee Reel. Water Con. Fee $254.11 Meter Size $0.00 Add'l Reel. Water Con. Fee $165.17 Meter Fee $0.00 SDCWA Fee $0.00 CFD Payoff Fee $6.58 PFF $0.00 PFF (CFD Fund) $0.00 License Tax $0.00 License Tax (CFD Fund) $0.00 Traffic Impact Fee $0.00 Traffic Impact (CFD Fund) $0.00 PLUMBING TOTAL $0.00 ELECTRICAL TOTAL $0.00 MECHANICAL TOTAL $0.00 Master Drainage Fee Sewer Fee $0.00 Redev Parking Fee $0.00 Additional Fees TOTAL PERMIT FEES $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $35.00 $24.00 $0.00 $0.00 $0.00 $0.00 $484.86 Total Fees:$484.86 Total Payments To Date:$165.17 Balance Due:$319.69 Inspector: BllDING PLANS IN STORAGE ATTACHED FINAL APPROVAL Date:Clearance: NOTICE: Please take NOTICfrthat approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as lees/exactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020fa), and file the protest and any other required information with the City Manager for -recessing in accordance with Cahsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, view, set aside, void, or annul their imposition. are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity ges, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any -xactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired. t"EKiVII i" APPLICATIONCITY OF CARLSBAD BUILDING DEPARTMENT1635 Faraday Ave., Carlsbad, CA 920081. PROJECT INFORMATION FOR OFFICE USEPLAN CHECK NO.EST. VAL. ~^> / -^^Plan Ck. DepositValidated py*DateAddress (include Bldg/Suite #)CONTACT PERSON (if different from "applicant)Business Name (arihis address)CGF"165=17Subdivision Name/Number Unit No.Phase No.Total # of unitsProposer} UseSO. FT.#of Stones # of Bedrooms # of Bathrooms Address City Agent for Contractor Q Owner Q Agent for Owner State/Zip Telephone Fax # f Name >sjL*. PROPERTY OWNER Address ?. oc City State/Zip Telephone # Name Address 5. CONTRACTOR - COMPANY NAME (Sec. 7031.5 Business and Professions Code: Any City or County wh issuance, alscf-requires the applicant for such permit to file a si [Chapter 9, cimmending with Section 7000 of Division 3 of exemption. Arty violation of Section 7031.5 by any applican -t/fl City State/Zip Telephone # ^quires a permit to construct, alter, improve, demolish or repair any structure, prior to its nt that he is licensed pursuant to the provisions of the Contractor's License Law Professions Code] or that he is exempt therehom, and the basis for the alleged bjec\s the applicant to a civi! penalty of rjdt more thar\five hundred dollars [5500)1. Designer Name State License # 6. WORKERS' COMPENSATION Workers' Compensation Declaration: I hereby affirm under penalty of perjury one of the following declarations: 0 I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. PI I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My worker's compensation insurance carrier and policy number are: Insurance Company Policy No. Expiration Date (THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS [$100] OR LESS) El CERTIFICATE OF EXEMPTION: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. WARNING: Failure to sgcpre workers' compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars (jjjjKJgj30Ljn_addition to the cost of compensation, damages as provided for in Section 3706 of the Labor code, interest and attorney's fees. 7. OWNER^BUILDER DECLARATION———~ -ZUl^i. 1 hereby affirm that I am exempt from the Contractor's License Law for the following reason: Pi I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-buiider will have the burden of proving that he did not build or improve for the purpose of sale). I I I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). D ( arn exempt under Section Business and Professions Code for this reason: 1. I personally plan to provide the major labor and materials for construction of the proposed property improvement. Q YES [~JNQ 2. 1 (have / have not) signed an application for a building permit for the proposed work. 3. I have contracted with the following person (firm) to provide the proposed construction (include name / address / phone number / contractors license number): 4. I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone 1 number / contractors license number): \ 5. I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone number / type \ of work):__ DATE^PROPERTY OWNER SIGNATURE COMPLETE THIS SECTION FOR NON-RESIDENTIAL BUILDING PERMITS ONLY Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? Q YES Q NO Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? d YES O NO Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? fl YES Q NO IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. 8. CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097li) Civil Code). LENDER'S NAME LENDER'S ADDRESS__ ___ 9. APPLICANT CERTIFICATION 1 certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all City ordinances and State laws relating to building construction. I hereby authorize representatives of the City of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: An OSHA permit is required for excavations over 5'0" deep and demolition or construction of structures over 3 stories in height. EXPIRATION: Every permit issued by the building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit or if the building or work authorized by such permit is suspended or abandoned days ^Section 106.4.4 Uniform Building Code}. '; at any time after the work is commenced for a period,oft ^ " APPLICANT'S SIGNATURE DATE WHITE: File YELLOW: Applicant PINK: Finance ?ERfcJT APPLICATIONCITY OF CARLSBAD BUILDING DEPARTMENT1635 Faraday Ave., Carlsbad, CA 920081, PROJECT INFORMATION FOR OFFICE USE ONLYPLAN CHECK NO.EST. VAL.Plan Ck. DepositValidated ByDateAddress (include Bldg/Suite #)Business Name (at this address)Legal Description Lot No.Subdivision Name/Number Unit No.Phase No.Total # of unitsAssessor's Parcel #Existing Use Proposed UseDescription of Work SQ. FT.#of Stories # of Bedrooms # of Bathrooms Name Address City 3. APPLICANT Q Contractor Q Agent for Contractor Q Owner D Agent for Owner State/Zip Telephone # Fax # Name 4. PROPERTY OWNER Address City State/Zip Telephone # Address City State/Zip Telephone #-Name fi. CONTRACTOR? COMPANY NAME (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law [Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Codel or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7O31.5 by any applicant for a permit subjects the applicant to^a civil penalty of not more than five hundred dollars IS500I). r W/(t»/ iitt& Name State License # > Designer Name State License K @5Z><?3<? Address License Class I*S Address City State/Zip Telephone # City Business License # /2 2L ^5/3 3 City State/Zip Telephone :6is , WORKERS COMPENSAT10R1: Workers' Compensation Declaration: I hereby affirm under penalty of perjury one of the following declarations: Q I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. Q I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My worker's compensation insurance carrier and policy number are: Insurance Company Policy No. Expiration Date (THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS [$100] OR LESS) i-V\n^ CERTIFICATE OF EXEMPTION: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. WARNING: Failure to secure worker*' compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars (S1,pj),OJW), in addition to the cost of compensation, damages as provided for in Section 3706 of the Labor code, interest and attorney's fees. 7. OWNER^UIWEB^CLA^^^ ~~ ~~~ I hereby affirm that I am exempt from the Contractor's License Law for the following reason: O I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). C] I; as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). n I am exempt under Section Business and Professions Code for this reason: 1. I personally plan to provide the major labor and materials for construction of the proposed property improvement. Q YES l~lNO 2. I (have / have not) signed an application for a building permit for the proposed work. 3. I have contracted with the following person (firm) to provide the proposed construction (include name / address / phone number / contractors license number): 4. I plan to provide portions of the work, but ! have hired the following person to coordinate, supervise and provide the major work (include name / address / phone number / contractors license number): 5. I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone number / type of work): PROPERTY OWNER SIGNATURE DATE COMPLETE THIS SECTION FOR Jtfp«-*BS«>CT7Ml BHILOINO^PERMITS ONLY , , Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? D YES D NO Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? Q YES d MO Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? Q YES O NO IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. 8. CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097(i) Civil Code). LENDER'S NAME _ LENDER'S ADDRESS I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all City ordinances and State laws relating to building construction. I hereby authorize representatives of the City of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: An OSHA permit is required for excavations over 5'0" deep and demolition or construction of structures over 3 stories in height. EXPIRATION: Every permit issued by the building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit or if the building or work authorized by such permit is suspended or abandoned al any time after the work is commenced for a period of 180 days (Section 106.4.4 Uniform Building Code). APPLICANT'S SIGNATURE DATE WHITE: File YELLOW: Applicant PINK: Finance City of Carlsbad Bldg Inspection Request For; 09/20/2005 Permit** CB051293 Title: TANBYTHESEA1010SFTI Description: VANILLA SHELL TO TANING SALON Type:TI Sub Type: COMM Job Address: 2744 CARLSBAD BL Suite: 118 Lot 0 Location: APPLICANT SHANTHI LACKEY Owner: Remarks: Inspector Assignment: PY Phone: 7608229498 Inspector: Total Time: CD Description 19 Final Structural 29 Final Plumbing 39 Final Electrical 49 Final Mechanical Requested By: TIM Entered By: CHRISTINE Act Comment Associated PCRs/CVs Inspection History Date Description Act Insp Comments 0770172005 17 Interior Lath/Drywall AP PD 06/28/2005 31 Underground/Conduit-Wiring WC PY 06/28/2005 34 Rough Electric AP PY 06/27/2005 14 Frame/Steel/Botting/Welding CO PY 06/27/2005 34 Rough Electric CO PY 06/2772005 44 Rough7Ducts7Dampers CO PY 06/13/2005 84 Rough Combo PA PY 06/09/2005 84 Rough Combo NR PY OK TO ONE SIDE DRYWALL NO ONE THERE NO PLANS City of Carlsbad Bldg Inspection Request For: 06/27/2005 Permit* CB051293 Title. TAN BY THE SEA 1010 SFTI Description: VANILLA SHELL TO TANING SALON inspector Assignment: PY Type:Tl Sub Type: COMM Job Address: 2744 CARLSBAD BL Suite: 118 Lot 0 Location: APPLICANT SHANTHI LACKEY Owner: ANASTASI DEVELOPMENT CO LLC Remarks: Phone: 7608229498 Inspector: Total Time: CD Description 34 Rough Electric Act Comment Requested By: TIM Entered By: JANEAN Associated PCRs/CVs Inspection History Date Description Act Insp Comments 06/13/2005 84 Rough Combo PA PY OK TO ONE SIDE DRYWALL 06/09/2005 84 Rough Combo NR py NO ONE THERE NO PLANS CITY OF CARLSBAD BUILDING DEPARTMENT DATE LOCATION_s2j!_£!i PERMIT NO. NOTICE (760) 602-2700 1635 FARADAY AVENUE TIME sJ ^-^-^ ^ FOR INSPECTION CALL (760) 602-2725. RE-INSPECTION FEE DUE? I ._ ' YES FOR FURTHER INFO/iriON! CONTACJff ^__^__ BUILDING i CODE ENFORCEMENT OFFICER EsGil Corporation In fartnersfiip witfi government for (RuiCtfing Safety DATE: June 3, 2005 a JURIS JURISDICTION: Carlsbad ^-Q PLAN REVIEWER a FILE PLAN CHECK NO.: O5-1293 SET: III PROJECT ADDRESS. 2744 Carlsbad Boulevard Suite 118 PROJECT NAME: Tan By The Sea Tanning Salon TI I The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: Esgil Corporation staff did not advise the applicant that the plan check has been completed. Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Telephone #: Date contacted: (by: ) Fax#: Mail Telephone Fax In Person REMARKS: By: Bryan Zuppiger Enclosures: Esgil Corporation D GA D MB D EJ D PC 05/25/O5 trnsmtl.dot 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858)560-1468 4 Fax (858) 560-1576 EsGil Corporation In Partnership with government for Quitting Safety DATE: May 7, 2005 Q APPLICANT JURISDICTION: Carlsbad OIPTANREVIEWER a FILE PLAN CHECK NO.: 05-1293 SET: II PROJECT ADDRESS: 2744 Carlsbad Boulevard Suite 118 PROJECT NAME: Tan By The Sea Tanning Salon TI The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: Shantht Lackey 4008 Alvila #H Carlsbad, CA 92008 Esgil Corporation staff did not advise the applicant that the plan check has been completed. Esgil Corporation staff did advise the applicant that the plan check has been completed.r \Person contacted: Shanthi Lackey tv',u] Telephone #: 7608229497 Datecontacted:5/?(0S"(by: ;c_ ) Fax#: Mail —-Telephone— Fax In Person REMARKS: By: Bryan Zuppiger Enclosures: Esgil Corporation D GA D MB D EJ D PC 05/02/05 trnsmtl.dot 9320 Chesapeake Drive, Suite 208 4 San Diego, California 92123 4 (858)560-1468 + Fax (858) 560-1576 Carlsbad 05-1293 May 7, 20O5 RECHECK PLAN CORRECTION LIST JURISDICTION: Carlsbad PLAN CHECK NO.: 05-1293 PROJECT ADDRESS: 2744 Carlsbad Boulevard Suite 118 SET: II DATE PLAN RECEIVED BY ESGIL CORPORATION: 05/02/05 REVIEWED BY: Bryan Zuppiger DATE RECHECK COMPLETED: May 7, 2005 FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and disabled access. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department or other departments. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. A. Please make all corrections on the original tracings and submit two new complete sets of prints to: See note #1. B. To facilitate rechecking, please identify, next to each item, the sheet of the plans upon which each correction on this sheet has been made and return this sheet with the revised plans. C. The following items have not been resolved from the previous plan reviews. The original correction number has been given for your reference. In case you did not keep a copy of the prior correction list, we have enclosed those pages containing the outstanding corrections. Please contact me if you have any questions regarding these items. D. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located on the plans. Have changes been made not resulting from this list? QYes QNo Carlsbad O5-1293 May 7, 2O05 • PLANS NOTE: The items listed below refer to the item numbers from previous list. These remaining items have not been adequately addressed. The notes in bold at the end of or contained within each item are to emphasize the remaining problem. 1. Please make all corrections on the original tracings, as requested in the correction list. Submit three sets of plans for commercial/industrial projects. For expeditious processing, corrected sets can be submitted in one of two ways: a) Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, and (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. b) - Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, and (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. 2. The person responsible for their preparation must sign all final sheets of plans. (California Business and Professions Code). 16. Provide an equipment schedule with manufacturer's specifications. How are these devices receiving electric? 19. Provide notes and/or details to show that the floor and wall finish in toilet rooms are surfaced with a smooth hard non-absorbent material extending five inches up the wall. Similar surfacing shall be provided on the walls from the floor to a height of 4 feet around urinals and within water closet compartments. CBC Section 807. The bathrooms are not shown on the plans. 20. In Group B Occupancies, if the number of employees exceeds four, provide separate toilet facilities for men and women. If "the total number of employees will not exceed four", and only one restroom is provided, note the words in quotation above on the floor plan. CBC UBC Section 2902.3. The bathrooms are not shown on the plans. 21. Note on the plans: "All exits are to be openable from inside without the use of a key or special knowledge." In lieu of the above, in a Group B, F, M or S occupancies, you may note "Provide a sign on or near the exit door, reading THIS DOOR TO REMAIN UNLOCKED DURING BUSINESS HOURS." This signage is only allowed at the main exit. UBC Section 1003.3.1.8. Carlsbad 05-1293 May 7, 2OO5 • ELECTRICAL (NATIONAL ELECTRICAL CODE) 25. WIRING METHODS: AC Cable is not allowed in A, B, E, H, and I occupancies. NM cable is restricted (without City approval) to one and two family dwellings. Note on plans that an equipment ground conductor is to be installed in all flexible conduits. Please note on plans. 27. The use of flexible metal conduit as a grounding means must comply with City Policy 84-36. Please note on plans. 29. Submit plan showing location of all panels. How are these devices receiving electric? 30. Submit panels schedules. How are these devices receiving electric? 31. Submit electrical load calculations. If equipment load is significant. 35. Indicate wiring method, i.e. EMT, metal flex at equipment. To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Bryan Zuppiger at Esgil Corporation. Thank you. Carlsbad 05-1293 May 7, 2O05 DISABLED ACCESS REVIEW LIST DEPARTMENT OF STATE ARCHITECT TITLE 24 The following disabled access items are taken from the 2001 edition of California Building Code, Title 24. Per Section 101.17.11, all publicly and privately funded public accommodations and commercial facilities shall be accessible to persons with disabilities. NOTE: All Figures and Tables referenced in this checklist are printed in the California Building Code, Title 24. • COUNTERS AND TABLES 86. Where fixed or built-in tables, counters or seats are provided for the public, and in general employee areas, 5% (but never less than one) must be accessible. CBC Section 1122B.1. This applies to the tanning booths and counter. END OF DOCUMENT EsGil Corporation In (Partnership with government for (Buiftfing Safety DATE: April 21, 2005 g APPLICANT ^TT JURIST> JURISDICTION: Carlsbad Q P|_AN~REVIEWER a FILE PLAN CHECK NO.: 05-1293 SET: I PROJECT ADDRESS: 2744 Carlsbad Boulevard Suite 118 PROJECT NAME: Tan By The Sea Tanning Salon TJ The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: Shanthi Lackey 4008 Alvila #H Carlsbad, CA 92008 Esgil Corporation staff did not advise the applicant that the plan check has been completed. Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Shanthi Lackey Telephone #: 760 822 9497 Date contacted^^bv^^ ) Fax #:~] 0 Q-~IS7 - Mail \ /Telephone . /Fax i/m Person REMARKS: By: Bryan Zuppiger Enclosures: Esgil Corporationn GA n MB n EJ n PC 04/11/05 tmsmti.dot 9320 Chesapeake Drive, Suite 208 * San Diego, California 92123 4> (858)560-1468 + Fax (858) 560-1576 Carlsbad 05-1293 April 21,2005 PLAN REVIEW CORRECTION LIST TENANT IMPROVEMENTS PLAN CHECK NO.: 05-1293 OCCUPANCY: B TYPE OF CONSTRUCTION: VN ALLOWABLE FLOOR AREA: unknown SPRINKLERS?: unknown DATE PLANS RECEIVED BY JURISDICTION: DATE INITIAL PLAN REVIEW COMPLETED: April 21, 2005 JURISDICTION: Carlsbad USE: Tanning Salon ACTUAL AREA: ±1OOO fta STORIES: unknown HEIGHT: unknown OCCUPANT LOAD: 1O DATE PLANS RECEIVED BY ESGIL CORPORATION: 04/11/05 PLAN REVIEWER: Bryan Zuppiger FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Code sections cited are based on the 1997 UBC. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans. TENANT IMPROVEMENTS WITHOUT SPECIFIC ENERGY DATA OR POLICY SUPPLEMENTS (1997UBC) tiforw.dot Carlsbad 05-1293 April 21,2005 • PLANS 1. Please make all corrections on the original tracings, as requested in the correction list. Submit three sets of plans for commercial/industrial projects. For expeditious processing, corrected sets can be submitted in one of two ways: a) Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, and (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. b) Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, and (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. 2. The person responsible for their preparation must sign all final sheets of plans. (California Business and Professions Code). 3. Indicate on the Title Sheet of the plans, the name of the legal owner and name of person responsible for the preparation of the plans. UBC Section 106.3.3. 4. Provide the correct address and suite number of tenant space on the plans. UBC Section 106.3.3. 5. Provide a statement on the Title Sheet of the plans stating that this project shall comply with the 2001 edition of the California Building Code (Title 24), which adopts the 1997 UBC, 2000 UMC, 2000 UPC and the 1999 NEC. 6. Provide a note on the site plan indicating the previous use of the tenant space or building being remodeled. UBC Section 106.3.3. 7. When the character of the occupancy or use changes within a building, the building must be made to comply with current Building Code requirements for the new occupancy. Please provide complete details to show the building will comply. UBC Section 3405. 8. Provide a plot plan showing the distance from the building to the property lines and the location of tenant space (or remodel) within the building. 9. Provide a fully dimensioned floor plan showing the size and use of all rooms or areas within the space being improved or altered. Draw the plans to scale and indicate the scale on the plan. UBC Section 106.3.3. The numbers do not add up. Carlsbad 05-1293 April 21, 2005 10. On the first sheet of the plans indicate: • The floor area of the remodeled area, • Type of construction of the existing building, • Sprinklers: Yes or No • Present and proposed occupancy classifications of the remodel area, • The story where the tenant improvement is located, • The occupant load of the remodel area(s). 11. Indicate the use of all spaces adjacent to the area being remodeled or improved. 12. Show any existing fire rated area separation walls, occupancy separation walls, demising walls, shafts or rated corridors. Identify and provide construction details for proposed new fire rated walls. 13. Specify on the plans the fire ratings of assemblies to protect penetrations or proposed openings in existing or new fire walls, floor-ceiling assemblies or roof-ceiling assemblies. 14. Identify existing walls to be removed, existing wails to remain and proposed new walls. Identify bearing walls, non-bearing walls, and shear walls. 15. Provide a note on the plans indicating if any hazardous materials will be stored and/or used within the building which exceed the quantities listed in UBC Tables 3-D and 3-E. 16. Provide an equipment schedule with manufacturer's specifications. 17. Glazing in the following locations should be of safety glazing material in accordance with UBC Section 2406.4 (see exceptions): a) Fixed and sliding panels of sliding door assemblies and panels in swinging doors other than wardrobe doors. b) Doors and enclosures for hot tubs, whirlpools, saunas, steam rooms, bathtubs and showers and in any portion of a building wall enclosing these compartments where the bottom exposed edge of the glazing is less than 60 inches above a standing surface and drain inlet. c) Fixed or operable panels adjacent to a door where the nearest exposed edge of the glazing is within a 24-inch arc of either vertical edge of the door in a closed position and where the bottom exposed edge of the glazing is less than 60 inches above the walking surface. d) Individual fixed or operable panels, other than those locations described above, that meet all of the following conditions: i) Exposed area of an individual pane is greater than 9 square feet, and: ii) Exposed bottom edge is less than 18 inches above the floor, and: iii) Exposed top edge is greater than 36 inches above the floor, and: iv) One or more walking surfaces are within 36 inches horizontally of the plane of the glazing. Carlsbad 05-1293 April 21, 2005 18. Provide a section view of all new steel interior partitions should the Building Type be non-combustable. Show: a) Type, size and spacing of studs. Indicate gauge for metal studs. Specify manufacturer and approval number or indicate "to be ICBO approved". b) Method of attaching top and bottom plates to structure. (NOTE: Top of partition must be secured to roof or floor framing, unless suspended ceiling has been designed for partition lateral load). c) Wall sheathing material and details of attachment (size and spacing of fasteners). d) Show height of partition and suspended ceiling, and height from floor to roof framing or floor framing. 19. Provide notes and/or details to show that the floor and wall finish in toilet rooms are surfaced with a smooth hard non-absorbent material extending five inches up the wall. Similar surfacing shall be provided on the walls from the floor to a height of 4 feet around urinals and within water closet compartments. Section 807. 20. In Group B Occupancies, if the number of employees exceeds four, provide separate toilet facilities for men and women. If "the total number of employees will not exceed four", and only one restroom is provided, note the words in quotation above on the floor plan. UBC Section 2902.3. 21. Note on the plans: "All exits are to be openable from inside without the use of a key or special knowledge." In lieu of the above, in a Group B, F, M or S occupancies, you may note "Provide a sign on or near the exit door, reading THIS DOOR TO REMAIN UNLOCKED DURING BUSINESS HOURS." This signage is only allowed at the main exit. UBC Section 1003.3.1.8. • ROOFING 22. Roof mounted equipment must be screened and roof penetrations should be minimized (City Policy 80-6). 23. Overflow roof drains shall terminate in an area where they will be readily visible and will not cause damage to the building. If the roof drain terminates through a wall, the overflow drain shall terminate 12" minimum above the roof drain. Policy 84-35. • ELECTRICAL (NATIONAL ELECTRICAL CODE) 24. Show on the plan the amperage of the electrical service, the location of the service panel and the location of any sub-panels. If service is over 200 amps, submit single line diagram, panel schedule and load calculations. 25. WIRING METHODS: AC Cable is not allowed in A, B, E, H, and I occupancies. NM cable is restricted (without City approval) to one and two family dwellings. Note on plans that an equipment ground conductor is to be installed in all flexible Carlsbad 05-1293 April 21,2005 conduits. 26. The UFER ground may only be a copper conductor for commercial and industrial electrodes. Rebar is allowed for residential use only up to 200 amperes. 27. The use of flexible metal conduit as a grounding means must comply with City Policy 84-36. 28. No wiring is permitted on the roof of a building and wiring on the exterior of a building requires approval by the Building Official. (City Policy) 29. Submit plan showing location of all panels. 30. Submit panels schedules. 31. Submit electrical load calculations. 32. Indicate existing main service size. 33. Indicate existing total main service load. 34. Indicate new additional loads. 35. Indicate wiring method, i.e. EMT, metal flex. 36. Show exit signs on the electrical lighting plan(s). As per Section 1003.2.8, provide two sources of power to exit signs and exit illumination. 37. Provide multiple switch lighting controls per Title 24, Part 6. • MECHANICAL 38. Show the location, type and size (BTU's) of all heating and cooling appliances or systems. 39. Provide mechanical ventilation in all rooms, capable of supplying outside air at a minimum rate of 15 cubic feet per minute per occupant. UBC, Section 1202.2.1. 40. Provide mechanical plans, showing existing and proposed HVAC equipment, ducts and access to equipment. 41. Detail access and working clearances to HVAC equipment. 42. Detail ladder access to roof mounted HVAC equipment. 43. Detail disposal of main condensate drainage from air conditioning units. UMC Section 309 Carlsbad 05-1293 April 21,2005 44. Detail overflow (secondary) condensate discharge from air conditioning units that are in a ceiling space, to a readily observable location. UMC Section 1105.12 45. Fire rated corridors are not to be used to convey air to or from rooms. UMC Section 601.1.1. • PLUMBING (UNIFORM PLUMBING CODE) 46. Provide complete plumbing plans, including: a) Complete drain, waste and vent plans. b) Provide gas line plans and calculations, showing pipe lengths and gas demands. UPC Section 1217.0 c) Provide complete water line sizing calculations, including the water pressure, pressure losses, water demands, and developed pipe lengths. UPC Section 610.0 d) Show water heater size, type and location on plans. UPC, Section 501.0 47. Show water heater size (1st hour rating), type, and location on plans. UPC Section 501.0. 48. Show that water heater is adequately braced to resist seismic forces. Provide two straps (one strap at top 1/3 of the tank and one strap at bottom 1/3 of the tank). UPC, Section 510.5. 49. Show P & T valve on water heater and detail drain line route from P & T valve to the exterior. UPC Section 608.4. 50. Show 1/4" per 12" slope on drain and waste lines. UPC Section 708.0. 51. Note on the plans that new water closets and associated flushometer valves, if any, shall use no more than 1.6 gallons per flush and shall meet performance standards established by the American National Standards Institute Standard A112.19.2. H & S Code, Section 17921.3(b). 52. Urinals and associated flushometer valves, if any, shall use no more than one gallon per flush and shall meet performance standards established by the American National Standards Institute Standard A112.19.2. H & S Code Section 17921.3(b). • ENERGY 53. Provide plans, calculations and worksheets to show compliance with current energy standards. 54. Provide complete energy designs for the proposed changes in envelope, lighting, and mechanical systems. Provide the completed ENV-, LTG-, and MECH- forms showing energy compliance. Carlsbad O5-1293 April 21,2005 55. On the plans clearly show the wall and roof insulation locations, thickness, and R-values, as per the energy design. 56. The completed and signed ENV-1, LTG-1, and MECH-1 forms must be imprinted on the plans. To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Bryan Zuppiger at Esgil Corporation. Thank you. Carlsbad 05-1293 April 21, 2O05 DISABLED ACCESS REVIEW LIST DEPARTMENT OF STATE ARCHITECT TITLE 24 The following disabled access items are taken from the 2001 edition of California Building Code, Title 24. Per Section 101.17.11, all publicly and privately funded public accommodations and commercial facilities shall be accessible to persons with disabilities. NOTE: All Figures and Tables referenced in this checklist are printed in the California Building Code, Title 24. . REMODELS. ADDITIONS AND REPAIRS 1. When alterations, structural repairs or modifications or additions are made to an existing building, that building, or portion of the building affected, is required to comply with all of the requirements for new buildings, per CBC Section 1134B.2. These requirements apply as follows: a) The area of specific alteration, repair or addition must comply as "new" construction. b) A primary entrance to the building and the primary path of travel to the altered area, must be shown to comply with all accessibility features. c) Existing sanitary facilities that serve the remodeled area must be shown to comply with all accessibility features. d) Existing drinking fountains (if any) must be shown to comply with all accessibility features. e) Existing public telephones (if any) must be shown to comply with all accessibility features. 2. If an unreasonable hardship finding is granted, priority should be given to those elements that will provide the greatest access, per CBC Section 1134B.2.1 Exception #1. The order of priority shown below should be followed: a) An accessible entrance. b) An accessible route of travel. c) At least one accessible restroom for each sex. d) Accessible telephones. e) Accessible drinking fountains. f) When possible, additional accessible elements such as parking, storage and alarms. • SITE PLAN REQUIREMENTS 3. Clearly show that the site development and grading are designed to provide access to all entrances and exterior ground floor exits, as well as access to normal paths of travel, per CBC Section 1127B.1. Where necessary to provide access, shall incorporate pedestrian ramps, curb ramps, stairways and handrails, etc. Carlsbad 05-1293 April 21,2005 4. When more than one building or facility is located on a site, accessible routes of travel shall be provided between buildings and accessible site facilities, per CBC Section 1127B.1. 5. The accessible route of travel shall be the most practical direct route between accessible building entrances, accessible site facilities, and the accessible entrance to the site. CBC Section 1127B.1. 6. Show, or note that at every primary public entrance, and at every major function area along, or leading to, an accessible route of travel, there is to be a sign displaying the international symbol of accessibility. Signs are required to indicate the direction to accessible building entrances and facilities, per CBC Sections H17B.5.7and 1127B.3. 7. Show that an accessible route of travel is to be provided to all portions of the building, to accessible building entrances and between the building and the public way, per CBC Section 1114B.1.2. 8. Where more than one route of travel is provided, all routes shall be accessible. CBC Section 1114B. 1.2. 9. Show that stairways occurring outside a building comply with CBC Section 1133B as follows: a) The upper approach and ail treads shall be marked with a strip of contrasting color as follows: i) >2" in width. ii) Placed parallel to and ^" from the nose of the step or landing. iii) The strip is required to be as slip resistant as the treads of the stairs. b) Treads shall be: i) Smooth, rounded or chamfered exposed edges. ii) Have no abrupt edges at the nosing projecting ^%" past the face of the riser above. iii) Open risers are not permitted. • ACCESSIBLE PARKING 10. Each lot or parking structure where parking is provided for the public, as clients, guests or employees, shall provide accessible parking as required by CBC Section 1129B. 11. Show that the accessible parking spaces are located, per CBC Section 1129B.1 as follows: a) On the shortest possible route to an accessible entrance, when serving a particular building. b) On the shortest route of travel to an accessible entrance of a parking facility. c) Spaces are to be dispersed and located closest to accessible entrances where buildings have multiple accessible entrances with adjacent parking. Carlsbad 05-1293 April 21,2005 12. Show on the site plan the required number of accessible parking spaces for new facilities. Per CBC Table 11B-7 the minimum number of spaces is: a) 1 for each 25 spaces up to 100 total spaces. b) 1 additional space for each 50 spaces for between 101 and 200 total spaces. c) 1 additional space for each 100 spaces for between 201 and 500 total spaces. d) For between 501 and 1000 total spaces, a minimum of 2% of the total number of spaces is required. e) For greater than 1000 spaces, 20 plus 1 for each additional 100 spaces. 13. Show that accessible parking spaces comply with CBC Section 1129B.4.1 as follows: a) Single spaces shall be 14' wide and outlined to provide a 9' parking area and a 5' loading and unloading area on the passenger side of the vehicle. b) When more than one space is provided, in lieu of providing a 14' space for each space, two spaces can be provided within a 23' area with a 5' loading zone between each 9'0" wide space. c) Each space is to be a minimum of 18' in depth. 14. At least one in every 8 accessible parking spaces shall be served by an access aisle >96" in width and designated as VAN ACCESSIBLE, per CBC Section 1129B.4.2. 15. The words "NO PARKING" shall be painted on the ground within each loading and unloading access aisle (in white letters no less than 12" high and located so that it is visible to traffic enforcement officials). CBC Section 1129B.4.2. 16. Ramps shall not encroach into any accessible parking space or the adjacent access aisle. CBC Section 1129B.4.3. 17. Show on the site plan that accessible parking space(s) are to be located such that disabled persons are not compelled to wheel or walk behind parked cars other than their own, per CBC Section 1129B.4.3. 18. Show that a bumper or curb is to be provided, and located at each space, to prevent encroachment of cars into the required width of walkways, per CBC Section 1129B.4.3. 19. Show or note that the maximum slope of the parking surface at the accessible space and adjacent access aisle, in any direction, is &*' per ft (2%), per CBC Section 1129B.4.3. Carlsbad 05-1293 April 21, 2005 20. Show or note on the plans that the accessible parking spaces are to be identified by a reflectorized sign, permanently posted immediately adjacent to and visible from each space, consisting of: a) A profile view of a wheelchair with occupant in white on dark blue background. b) The sign shall >70 in.2 in area. c) When in the path of travel, they shall be posted >80" from the bottom of the sign to parking space finished grade. d) Signs may also be centered on the wall of the interior end of the parking space >36" from the parking space finished grade, ground or sidewalk. e) Spaces complying with Section 1129B.4.2 shall have an additional sign "Van-Accessible" mounted below the symbol of accessibility per Section 1129B.5. f) In addition, the surface of each accessible space is required to be marked with the international symbol of accessibility. 21. Show, or note, that an additional sign shall also be posted in a conspicuous place at each entrance to off street parking facilities, or immediately adjacent to and visible from each stall or space. The sign shall be >17" x 22" with lettering not ^" in height. Per CBC Section 1129B.5 required wording is as follows. "Unauthorized vehicles parked in designated accessible spaces not displaying distinguishing placards or license plates issued for persons with disabilities may be towed away at owner's expense. Towed vehicles may be reclaimed at or by telephoning ." 22. Show that all vertical entrances to, and vertical clearances within, parking structures have a vertical clearance of >8'-2" where required for access to accessible parking spaces, per CBC Section 1130B. • CURB RAMPS 23. Curb ramps shall be constructed where a pedestrian way crosses a curb or at each corner of a street intersection, per CBC Section 1127B.5.1. 24. Plans shall show that curb ramps are >48" wide with a slope of ^ :12 (8.33%), per Sections 1127B.5.2 and 1127B.5.3. The lower end of each curb ramp shall have a 1/2" lip beveled 45°, per CBC Section 1127B.5.5. 25. Show that the landing at the top of the curb shall be level and >48" depth for the entire width of the curb ramp. CBC Section 1127B.5.4. 26. The slope of the fanned or flared sides of curb ramps shall not exceed 1:10, per CBC Section 1127B.5.4. 27. Show or note that the surface of all curb ramps and the flared sides are to be slip resistant, and contrasting from the adjacent sidewalk finish, per CBC Section 1127B.5.6. Carlsbad 05-1293 April 21,2O05 28. Provide details or note on the plans that all curb ramps have a grooved border 12" wide at the level surface of the sidewalk along the top and each side approximately Vo.c., per CBC Section 1127B.5.7. 29. Show that detectable warnings, extending the full width and depth of the curb ramp, inside the grooved border are to be installed if the slope is <1:15 (6.66%), per Section 1127B.5.8. These consist of raised truncated domes with a diameter of 0.9" at the base, tapering to 0.45" at the top. Spacing shall be 2.35" o.c. Only approved DSA/AC detectable warning products and directional surfaces shall be installed. 30. Locate curb ramps to prevent obstruction by blocked cars, per CBC Section 1127B.5.9. • WALKS AND SIDEWALKS 31. If any proposed walks slope >1:20 (5%) they must comply with ramp requirements, per CBC Section 1133B.5.1. 32. Walks along an accessible route of travel are required to be >48" minimum in width and have slip resistant surfaces, per CBC Section 1133B.7. 33. The maximum permitted cross slope shall be %" per ft., per CBC Section 1133B.7.1.3. 34. Show or note that any abrupt level changes will be ^4" along any accessible route of travel. When changes do occur, they shall be beveled with a slope of <l:2. Level changes of ^" may be vertical. NOTE: If level changes >Yz\ they must comply with the requirements of curb ramps. 35. Show that a 60" x 60" level area is provided at areas where a door (or gate) swings toward the walk in the accessible route of travel, per CBC Section 1133B.7.5. Show that the walk extends >24" beyond the strike edge of the strike edge of any door (or gate) that swings toward the walk. 36. Show or note that >80" headroom is to be provided from alt walkway surfaces to obstructions, per CBC Section 1133B.8.2. 37. Show that walks with continuous gradients are provided with level areas >5'0" long at intervals of 400'0" maximum, per CBC Section 1133B.7.6. 38. If grated openings are to be provided in the path of travel, they are to be limited to &" in the direction of travel, per CBC Section 1133B.7.2. Revise plans to show, or note, compliance. 39. Show that a 36" wide detectable warning material is provided at boundaries between walkways and vehicular ways. Material shall comply with criteria of CBC Sections 1133B.8.3 through 1133B.8.5, per CBC Section 1133B.8.5. 40. Plans indicate that more than one route of travel is to be provided. Revise plans to show that all routes are to be made accessible, per CBC Section 1127B.1. . PEDESTRIAN RAMPS AND STAIRWAYS Carlsbad 05-1293 April 21, 20O5 41. Show that any path of travel with a slope >1:20 (5%) complies with pedestrian ramp requirements, per CBC Section 1133B.5. 42. The allowable slope for an accessible ramp is ^:12 (8.33%), per CBC Section 1133B.5.3. Revise plans to show the least possible slope is being provided for all ramps, per CBC Section 1133B.5.1. 43. The allowable cross slope at pedestrian ramps shall be ^A" per ft (2%), per CBC Section 1133B.5.3.1. 44. Show or note that ramp surfaces will be slip resistant. 45. Ramps shall have a minimum width of 48 inches, per CBC Section 1133B.5.2.2. Where a ramp serves a building having an occupant load of 300 or more, the minimum clear width shall be 60 inches. 46. Revise plans to show required landings at the top and bottom of ramps, per CBC Section 1133B.5.4. a) The bottom landing shall be >72" in the direction of travel. b) The top landing shall be a >60" x 60". 47. Show that the required intermediate landing is provided, per CBC Section 1133B.5.4 as follows: a) >60" long where the elevation change is >30". b) >72" long at direction changes >30°. 48. Revise plans to show the minimum required depth of landing where a door swings over the top landing. The minimum depth of the landing is required to be equal to the door width, plus 42", per CBC Section 1003.3.4.4. 49. Plans shall show that the strike edge distances at doors comply with the requirements of CBC Section 1133B.5.4.4, as follows: a) >24" at exterior ramps. b) >18" at interior ramps. 50. Show handrails at each side of ramp(s) which are shown to be >1:20 (5%) in slope, per CBC Section 1133B.5.5. 51. Show that handrails are>1%" but ^%" in any cross sectional dimension. Additionally, show that the handrails are placed a >1 !4" from any wall, per CBC Section 1133B.5.5. 52. Show or note that handrails meet the following requirements, per CBC Section 1133B.5.5: a) Are continuous. b) Are to be located >34" but =38" above the ramp surface. c) Extend >12" beyond both the top and bottom landings. d) Ends are to be returned. Carlsbad O5-1293 April 21,2005 53. Where the ramp surface is not bounded by a wa!! or fence and the ramp exceeds 10' in length, the ramp shall comply with one of the following requirements, per CBC Section 1133B.5.6: a) A guide curb a minimum of 2" in height shall be provided at each side of the ramp; or b) A wheel guide rail shall be provided, centered 3" ± 1" above the surface of the ramp. 54. Note that all wall surfaces, adjacent to handrails, will be free of sharp or abrasive elements, per CBC Section 1133B.5.5.1 (i.e., no stucco). 55. Stair treads shall be no less than 11" deep, measured from riser to riser. CBC Section 1133B.4.5.3. This applies even if basic UBC provisions may allow a narrower tread. 56. Show or note that interior stair treads are marked at the upper approach and the lower tread of each stair, by a strip of clearly contrasting color, per CBC Section 1133B.4.4, as follows: a) At least 2" wide (but not more than 4" wide). b) Placed parallel to and not more than 1" from the nose of the step or landing. c) The strip shall be as slip resistant as the other treads of the stair. 57. Note that all tread surfaces comply with CBC Section 1133B.4.5, as follows: a) Stair treads shall be no less than 11" deep, measured from riser to riser. b) Be slip resistant. c) Have smooth, rounded or chamfered exposed edges. d) Have no abrupt edges at the nosing. e) Nosing shall not project >114" past the face of the riser above. f) Open risers are not permitted. • ENTRANCES AND CIRCULATION 58. Elevator access must be provided to upper and lower levels, unless it can be shown that an exception in CBC Section 1103B.1 is applicable. 59. In new buildings where elevators are required pursuant to Section 1103B.1 and which exceed 10,000 square feet on any floor, an accessible means of vertical access (via ramp, elevator or lift) shall be provided within 200 feet of travel of each stairs and each escalators. CBC Section 1103B.1. 60. Floors of a given story shall be a common level throughout, or shall be connected by pedestrian ramps, elevators or lifts. CBC Section 1120B.1. 61. Revise plans to show that all entrances, and exterior ground level exits, are accessible, per Section 1133B.1. 62. Every corridor serving an occupant load of 10 or more shall not be less than 44" in width. CBC Section 11338.3.1. Corridors serving an occupant load of less than 10 shall not be less than 36" in width. Carlsbad 05-1293 April 21, 2005 • DOORS 63. Revise plans, or door schedules, to show that every required passage door has >32" clear width, per CBC Section 1133B.2. 64. Where a pair of doors is utilized, at least one of the doors shall provide a clear, unobstructed opening width of 32 inches, per CBC Section 1133B.2.3.1. 65. Show, or note, that there is a level floor or landing on each side of all doors. The floor or landing is to be ^2" lower than the doorway threshold, per CBC Section 1133.2.4.1. 66. Show or note that all hand-activated door opening hardware meets the following requirements, per CBC Section 1133B.2.5.2: a) Latching, or locking, doors in a path of travel are operated with a single effort by lever type hardware, by panic bars, push-pull activating bars, or other hardware designed to provide passage without requiring the ability to grasp the opening hardware. b) Is to be centered >30" but ^4" above floor. 67. Show or note that the maximum effort to operate doors shall not exceed 8-Yz pounds for exterior doors and 5 pounds for interior doors, with such pull or push effort being applied at right angles to hinged doors and at the center plane of sliding or folding doors. When fire doors are utilized, the maximum effort to operate the door may be increased to not exceed 15 pounds. CBC Section 1133B.2.5. 68. Show or note that the lower 10" of all doors comply with CBC Section 1133B.2.6, as follows: a) To be smooth and uninterrupted, to allow the door to be opened by a wheelchair footrest, without creating a trap or hazardous condition. b) Narrow frame doors may use a 10" high smooth panel on the push side of the door. 69. Plans show that turnstiles are used. Provide fully controlled access. Revise plans to show a door (or gate) that is accessible and adjacent to each turnstile entrance (or exit). This passageway is to be >32" clear opening and is to remain unlocked during business hours. See CBC Section 1133B.2.3.4. 70. Show that the minimum strike edge distances are provided at the level area on the side to which a door (or a gate) swings, per CBC Section 1133B.2.4.3: a) >24" at exterior conditions. b) >18" at interior conditions. c) >12" on the push side, if the door has both a latch and a closer. Figure 11B-26A. d) Where a door is located in a recess or alcove where the distance from the face of the wall to the face of the door is greater than 8 inches, the above clearances shall apply. CBC Section 1133B.2.4.5. Carlsbad O5-1293 April 21, 2005 71. Show a level area, or landing, per CBC Section 1133B.2.4.2: a) >60" in the direction of door swing. b) >48" in the direction opposite the door swing (or 44" if doors don't have latches or closers). 72. Show that the space between two consecutive door openings in a vestibule, which serves spaces other than a required exit stairway: a) Provide >48" clear space from any door opening into the vestibule when door is open 90°, per CBC Section 1133B.2.4.4. b) Doors in series shall swing either: i) In the same direction. ii) Away from the space between the doors. • SPECIAL HAZARDS 73. Provide details or interior elevations to show that objects projecting from walls with their leading edges comply with CBC Section 1133B.8.6: a) >27" but ^SO" above finished floor protrude ^" into walks, halls, corridors, passageways or aisles. b) ^7" or >80" above finished floor may protrude any amount. c) Freestanding objects mounted on posts or pylons may overhang ^2" into the walk, hall, etc. if >27" but ^0" above ground surface or finished floor. 74. If a walk crosses or adjoins a vehicular way and walking surfaces are not separated by curbs or other elements, show that the boundary is defined, per CBC Section 1133B.8.5, by a continuous detectable warning which is: a) >36" in width. b) Only approved DSA/AC detectable warning products and directional surfaces shall be installed. • SANITARY FACILITIES 75. Alt sanitary facilities are required to be accessible, unless the enforcing agency determines that complying sanitary facilities are accessible within a reasonable distance of accessible area, per CBC Section 1115B.1. 76. Where separate nonaccessible facilities are provided for each sex, separate accessible facilities are required to be provided for each sex as well. Where nonaccessible unisex facilities are provided, at least one accessible unisex facility is required to be provided within close proximity to the non-accessible facility, per CBC Section 1115B.2. Carlsbad 05-1293 April 21,2005 77. Show that passageways leading to sanitary facilities have required clear access widths, per CBC Section 1115B.4. Show that all doorways have: a) >32" clear opening. b) A clear area: i) >60" in the direction of the door swing, ii) >44" away from the direction of door swing. c) All strike edge clearance dimensions are required to be met (i.e. 18" strike edge distance). 78. Note that the doorways leading to sanitary facilities shall be identified, per CBC Section 1115B.5, as follows: a) An equilateral triangle %" thick with edges 12" long and a vortex pointing upward at men's rest rooms. b) A circle %" thick, 12" in diameter at women's rest rooms. c) A 12" diameter circle with a triangle superimposed on the circle and within the 12" diameter at unisex rest rooms. d) The required symbols shall be centered on the door at a height of 60". e) Braille signage shall also be located on the wall adjacent to the latch outside of the doorways leading to the sanitary facilities, per CBC Section 1117B.5.7. • SINGLE ACCOMMODATION FACILITIES 79. Show a sufficient space in the toilet room for a wheelchair to enter the room and close the door, per CBC Section 1115B.7.2. The space is required to be: a) >60" diameter. b) A T-shaped space as shown in CBC Figure 11B-12(a) and (b). c) Doors are not permitted to encroach into this space by more than 12 inches. 80. Show that the water closet is located in a space, per CBC Section 1115B7.2, which provides: a) A minimum side clearance of either: i) >28" from a fixture. ii) >32" from a wall on one side. b) >48" clear space in front of the water closet. Carlsbad 05-1293 April 21,2005 • RESTROOM FIXTURES AND ACCESSORIES 81. Show, or note, on the plans that the accessible water closets meet the following requirements, per CBC Section 1115B.2.1: a) The seat is to be >17" but ^ 9" in height. b) The controls for flush valves shall be: i) Mounted on the side of the toilet area, ii) Be ^-4" above the floor. 82. Show, or note, on the plans that accessible urinals meet the following requirements, per CBC Section 1115B.2.1.1: a) The rim of at least one urinal shall: i) Project at least 14" from the wall, ii) Be ^7" above the floor. b) The control mechanism is be located ^4" above the floor. c) >30" x 48" clear floor space is provided in front of the accessible urinal. 83. Show that accessible lavatories comply with the following, per CBC Sections 1115B.2.1.2: a) >30" x 48" clear space is provided in front for forward approach. The clear space may include knee and toe space beneath the fixture. b) When lavatories are adjacent to a side wall or partition, there shall be a minimum of 18" to the center line of the fixture to the wall. c) The counter top is ^4" maximum above the floor. d) >29" high, reducing to 27" at a point located 8" back from the front edge. e) >9" high x 30" wide and 17" deep at the bottom. f) Hot water pipes and drain lines are insulated. 84. Show that grab bars comply with the following, per CBC Section 1115B.8: a) Grab bars shall be located on each side or one side and the back of the water closet stall or compartment. b) They shall be securely attached 33" above the floor, and parallel. NOTE: Where a tank-type toilet is used which obstructs placement at 33", the grab bar may be installed as high as 36". c) Grab bars at the side shall be located: i) 15" to 161/2" (±1") from the center line of the water closet stool, ii) Be >42" long with the front end positioned 24" in front of the stool, iii) Total length of bars at the back shall be >36". d) The diameter, or width, of the grab bar gripping surface is >1%" but ^A", or the shape shall provide an equivalent gripping surface. Carlsbad 05-1293 April 21, 2005 e) If mounted adjacent to a wall, the space between the wall and the grab bar shall be 11/2". f) Be designed to support 250#. 85. Show on the plans ^-0" height for: a) The operable parts of at least 1; i) Paper towel dispenser. ii) Sanitary napkin dispenser. iii) Waste paper disposal. iv) Other similar dispensing and/or disposal fixtures. b) The bottom edge of mirrors. • COUNTERS AND TABLES 86. Where fixed or built-in tables, counters or seats are provided for the public, and in general employee areas, 5% (but never less than one) must be accessible. CBC Section 1122B.1. This applies to the tanning booths. END OF DOCUMENT Carlsbad O5-1293 April 21, 2005 JURISDICTION: Carlsbad VALUATION AND PLAN CHECK FEE PLAN CHECK NO.: 05-1293 PREPARED BY: Bryan Zuppiger DATE: April 21, 2005 BUILDING ADDRESS: 2744 Carlsbad Boulevard Suite 118 BUILDING OCCUPANCY: B TYPE OF CONSTRUCTION: VN BUILDING PORTION Tl Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code AREA ( Sq. Ft.) 1000 cb Valuation Multiplier City Valuation By Ordinance Reg. Mod. VALUE ($) 31,310 31,310 $254.11 Plan Check Fee by Ordinance Type of Review: f~l Repetitive Fee Repeats Complete Review D Other ,—, Hourly Structural Only Hour Esgll Plan Review Fee $165.17 $142.30 Comments: macvalue.doc PLANNINC/ENCIMEERING APPROVALS PERMIT NUMBER CB ADDRESS DATE US RESIDENTlAt * RESIDENTIAL ADDITION MINOR $1O,OOO.OO) TENANT IMPROVEMENT PLAZAlCAMINQ KEAE CARLSBAD COMPANY STORES VILLAGE FAIRE COMPLETE OFFICE.BUILDINC- OTHER PLANNER DATE ENGINEE DATE C- April 14,2005 TO: BUILDING DEPARTMENT FROM: Assistant Planner, Redevelopment Department TENANT IMPROVEMENTS TO A RETAIL SUITE LOCATED AT 2744 CARLSBAD BLVD. SUITE 118 PLAN CHECK NO. CB051293 I have reviewed the building plans for the above referenced project. The retail use component at the subject property received approval through Major Redevelopment Permit (RP 01-06} on June 16, 2002. The project does not require any additional land use permits because the proposed work qualifies as an interior improvement to the approved structure. Therefore, the Housing & Redevelopment Department supports the issuance of building permit. This information has been entered into Permits Plus. If you have any questions, please contact me at x2813. CLIFF JONES Carlsbad Fire Department 051293 1635 Faraday Ave. Carlsbad, CA 92008 Plan Review Requirements Category: Date of Report: 04/08/2005 Fire Prevention (76QJ 602-4660 Building Plan Reviewed by: Name: Address: City, State: Shanthi Lackey 4008 Aguila Suite H Carlsbad CA 92008 Plan Checker: Job Name: Job Address: Job#: 051293 Tan by the Sea 2744 Carlsbad Blvd. Bldg #: CB051293 Ste. or Bldg. No. 118 Approved The item you have submitted for review has been approved. The approval is based on plans, information and / or specifications provided in your submittal; therefore any changes to these items after this date, including field modifications, must be reviewed by this office to insure continued conformance with applicable codes and standards. Please review carefully all comments attached as failure to comply with instructions in this report can result in suspension of permit to construct or install improvements. D Approved Subject to The item you have submitted for review has been approved subject to the attached conditions. The approval is based on plans, information and/or specifications provided in your submittal. Please review carefully all comments attached, as failure to comply with instructions in this report can result in suspension of permit to construct or install improvements. Please resubmit to this office the necessary plans and / or specifications required to indicate compliance with applicable codes and standards. Incomplete The item you have submitted for review is incomplete. At this time, this office cannot adequately conduct a review to determine compliance with the applicable codes and / or standards. Please review carefully all comments attached. Please resubmit the necessary plans and / or specifications to this office for review and approval. Review FD Job# 1st ?nH 3rd 051293 FDFile# Other Agency ID ,. BUS 200A. CIR NO. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 PANEL V SCHEDULE NO. OF OUTLETS ^— , t; I I | I ( 6 i 7 7 €C IX 6 7 (j; i i 8 <>i i CONNECTED WATTS/LINE WATTS L-1 bbO I 80 \2JcPsi eo H2O |V.O 1920 H<00 1500 L-2 835 2060 1^30 3I&O 112-° 11 20 -^ 855 L-3 (EfeO 2080 I^)2O I9£0 H20 1*120 Hfeo H80 LC, LOAD X 25% TOTAL CONNECTED WATTS MAXIMUM WATTS LC. LOAD LOCATION: TENANT SPACE CIRCUIT BREAKERS SERIES RATED W>o ISO 635 2O£Oizto 2.O8O |2bO __^ I C)^3 1 Cl Or^\ 3 180 H2O I^2LP I*12O I^2O 1120 H3U3 i^2Di<uo i ^20 Mti>O 4^0 3M835 o7<?^ 4354*- H3S44 AMP ao 20 20 30 20 30zo 5*0 20so 20 20 20 2O 20 20 zo 20 20 i5 IS P 1 1 *r ,- 1 £ 2. — — 2- 2, —— Z 2, _- — £ — LUuA 1 lUiN RETAIL -R^T^L. P.£TA4U fi^ST^oot^ ^ i^ t ft 1 1rs,t_-\ '*• ^-^ RXSTE.OOM RET7HL. p^oof- HEAT porap B.EO" I P^joF1 ' tieM" po rip E> &-D, — i B^> -£Beo-B " Bg.o -2. E>£~D -^ B&0-.-1 BVZ^>- 5 BBo-H £>Eo**".S. IV i» • • /Vl^. HA^P*-fiT2_ -^PA66. /V^R Kftt4pi_m2. ^>p>>CJi. i ' ' ' , , , . > * T- v VOLTAGE 120/208V-30-4W MAINS LUGS ONLY MOUNTING FLUSH FEEDER AMPS 121 Tftii 99Z9-19C998 •oui ssdU||8M pue 6uwuei so-c-c BO 'peqs|jeo License Detail Page 1 of 2 California Home Tuesday,JL License Detail Contractor License # 850939 CALIFORNIA CONTRACTORS STATE LICEN DISCLAIMER A license status check provides information taken from the CSLB license data base. Before on this information, you should be aware of the following limitations: • CSLB complaint disclosure is restricted by law (B&P_7124J5). If this entity is subject tc complaint disclosure, a link for complaint disclosure will appear below. Click on the lin button to obtain complaint and/or legal action information. • Per B&P 7071,17, only construction related civil judgments reported to the CSLB are disclosed. • Arbitrations are not listed unless the contractor fails to comply with the terms of the arbitration. • Due to workload, there may be relevant information that has not yet been entered ont Board's license data base. * * * Extract Date: 06/07/2005 Business Information * * * CHRISTOPHER KILBY 426 BORDEN ROAD SAN MARCOS, CA 92069 Business Phone Number: (760) 500-0097 Entity: Sole Ownership Issue Date: 12/10/2004 Expire Date: 12/31/2006 * * *License Status * This license is current and active. All information below should be reviewed. * * * Classifications * * * Class B GENERAL Description BUILDING CONTRACTOR * * *Bonding Information * * * CONTRACTOR'S BOND: This license filed Contractor's Bond number 100000759 in the ai $10,000 with the bonding company http://www2.cslb.ca.gov/CSLB_LIBRARY/License+Detail.asp 6/7/2005 License Detail Page 2 of 2 AMERICAN CONTRACTORS INDEMNITY COMPANY. Effective Date: 11/08/2004 Workers Compensation Information * * ** * * This license is exempt from having workers compensation insurance; they certified that the} employees at this time. Effective Date: 11/05/2004 Expire Date: None P_e_r_s_o n n e_| _LIi st Ljcense Number Request Contractor Name Request Personnel Name Request Salesperson Request Salesperson Name Request © 2005 State of California. Conditions of Use Privacy Policy http://www2.cslb.ca.gov/CSLB_LIBRARY/License+Detail.asp 6/7/2005