Loading...
HomeMy WebLinkAbout2744 CARLSBAD BLVD; 106; CB091594; Permit10-28-2009 City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Commercial/Industrial Permit Permit No: CB091594 Building Inspection Request Line (760) 602-2725 Job Address: Permit Type: Parcel No: Valuation: Occupancy Group: Project Title: Applicant: HUNT KENNETH 2744 CARLSBAD BL CBAD St: 106 Tl Sub Type: COMM 2031722701 Lot#: 0 $55,650.00 Construction Type: 5B Reference #: JADE SALON- 1590 SF SALON TO SALON/DAY SPA/SPACE INCLU.STES. 104 & 106 Owner: Status: Applied: Entered By: Plan Approved: Issued: Inspect Area: Plan Check#: ISSUED 09/28/2009 KG 10/28/2009 10/28/2009 LUCKMAN CHARLES&DENISE TRUST 06-26-95 2744 CARLSBAD BLVD CARLSBAD CA 92008 760-805-6747 2744 CARLSBAD BLVD #209 CARLSBAD CA 92008 Building Permit Add'l Building Permit Fee Plan Check Add'l Plan Check Fee Plan Check Discount Strong Motion Fee Park Fee LFM Fee Bridge Fee BTD #2 Fee BTD #3 Fee Renewal Fee Add'l Renewal Fee Other Building Fee Pot. Water Con. Fee Meter Size Add'l Pot. Water Con. Fee Reel. Water Con. Fee D Green Bldg Stands (SB14 $445.73 $0.00 $289.72 $0.00 $0.00 $11.69 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 UILDTNG PLA$$ STORAGE$ioo ATTACHED Meter Size Add'l Reel. Water Con. Fee Meter Fee SDCWA Fee CFD Payoff Fee PFF (3105540) PFF (4305540) License Tax (3104193) License Tax (4304193) Traffic Impact Fee (3105541) Traffic Impact Fee (4305541) PLUMBING TOTAL ELECTRICAL TOTAL MECHANICAL TOTAL Master Drainage Fee Sewer Fee Redev Parking Fee Additional Fees HMP Fee TOTAL PERMIT FEES $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $41.00 $20.00 $26.00 $0.00 $0.00 $0.00 $0.00 ?? $835.14 Total Fees:$835.14 Total Payments To Date:$83514 Balance Due:$0.00 SInspector:AV FINAL APPROVAL Clearance: NOTICE: Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired. CITY OF CARLSBAD Building Permit Application 1635 Faraday Ave., Carlsbad, CA 92008 760-602-2717 / 2718 / 2719 Fax: 760-602-8558 wwyy.ca risbadca.gov Plan Check No! DESCglPpONJJF JJMJRK: Include Square Feet of Affected Area(s) (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior tp its issuanc/ al^o requires the appjicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law (Chapter 9, commending with Section TOGO of Division 3 of theBusiness and Professions Code) or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to acivil penalty of not more than five hundred dollars {$500}). Workers' Compensation Declaration: / hereby affirm under penalty of perjury one of the following declarations: L~] I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this perm it is issued. LJ I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Insurance Co. Policy No. Expiration Date This section need not be completed if the permit is for one hundred dollars ($100) or less. •^^Certificate of Exemption: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. WARNING: Failure to secure workers' compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars (&100.000), in addition to the cost of compensation, damages as pj^videdjor in Section 3706 of the Labor code, interest and attorney's fees. >£T CONTRACTOR SIGNATURE DATE to - zt - I hereby affirm that I am exempt from Contractor's License Law for the following reason: n I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). D I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). n I am exempt under Section Business and Professions Code for this reason: 1.1 personally plan to provide the major labor and materials for construction of the proposed property improvement, n Yes Q No 2.1 (have / have not) signed an application for a building permit for the proposed work. 3.1 have contracted with the following person (firm) to provide the proposed construction (include name address / phone / contractors' license number): 4.1 plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone / contractors' license number): 5.1 will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone / type of work): NATURE DATE Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505,25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? D Yes D No Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? n Yes d No Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? O Yes D No IF ANY OF THE ANSWERS ARE YES, / EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. I hereby affirm that there is a construction lending agency for the performance of the work this permit is issued (Sec. 3097 (i) Civil Code). Lender's Name Lender's Address I certify that I have read the application and state that trie above information is correct and that the information on the plans is accurate. I agree to comply with all City ordinances and State laws relating to building construction. I hereby authorize representative of (tie City of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: An OSHA permit is required for excavations over 5'G" deep and demolition or construction of structures over 3 stories in height. EXPIRATION: Every permit issued by the Building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit or if the^uilding or work authorized by stir/permitis'suspended or abandoned at any time after the work is commenced for ajjeriod of 180 days (Section 106.4.4 Uniform Building Code). JS$APPLICANT'S SIGNATURE vork authorize felx"^DATE City of Carlsbad final Building Inspection Dept: BuHt Plan Check #: / Permit #: Project Name: Address: Contact Person: Sewer Dist: Inspected -. Bv: s*JL Inspected Bv: Inspected Bv: ling Engineering \ Planning CMWD CB091594 JADE SALON- 1590 SF SALON TO SALON/DAY SPA/SPACE INCLU.STES. 104 & 2744 CARLSBAD BL #106 ROBERT CA ^ Phone: 9517751541 Water Dist: CA Date Inspected: /<?^Y^"< Date Inspected: Date Inspected: StLite Fire Date: 12/1 1/2009 Permit Type: Tl Sub Type: COMM 106 Lot: 0 ) i Approved: }{J Disapproved: Approved: Disapproved: Approved: Disapproved: Comments: City of Carlsbad Final Building Inspection Dept: Buying Engineering Planning CMWD St Lite Fire Plan Check #: ( Permit #: Project Name: Address: Contact Person: Sewer Dist: Inspected Bv: Inspected Bv: Inspected Bv: Comments: CB091594 JADE SALON- 1590 SF SALON TO SALON/DAY SPA/SPACE INCLU.STES. 104 & 106 2744 CARLSBAD BL #106 ROBERT Phone: 9517751541 CA Water Dist: CA Date Inspected: Date Inspected: Date Inspected: Date: Permit Type: Sub Type: Lot: 0 Approved: Approved: Approved: 12/11/2009 Tl COMM Disapproved: Disapproved: Disapproved: Inspection List Permit#: CB091594 Type: Tl COMM Date Inspection Item 12/11/200989 Final Combo 12/11/200989 Final Combo 11/19/2009 14 Frame/Steel/Bolting/Weldin 11/19/200917 Interior Lath/Drywall 11/19/200934 Rough Electric 11/17/2009 14 Frame/Steel/Bolting/Weldin 11/17/2009 21 Underground/Under Floor 11/17/2009 24 Rough/Topout 11/17/2009 34 Rough Electric 11/17/2009 44 Rough/Ducts/Dampers Inspector PY PY PY PY PY PY PY PY PY Act Rl AP AP AP AP PA AP AP NR NR JADE SALON-1590 SF SALON TO SALON/DAY SPA/SPACE INCLU.STES. 10 Comments AM PLEASE Thursday, December 17, 2009 Page 1 of 1 City of Carlsbad Bldg Inspection Request For: 12/11/2009 Permit* CB091594 Title: JADE SALON-1590 SF SALON TO Description: SALON/DAY SPA/SPACE INCLU.STES. 104 & 106 Inspector Assignment: PY 2744 CARLSBAD BL 106 Lot: 0 Type:TI Sub Type: COMM Job Address: Suite: Location: APPLICANT HUNT KENNETH Owner: Remarks: AM PLEASE Total Time: Phone: 9517751541 Inspector: Requested By: ROBERT Entered By: JANEAN CD Description 19 Final Structural 29 Final Plumbing 39 Final Electrical 49 Final Mechanical Act Comments Comments/Notices/Holds Associated PCRs/CVs Original PC# Date 11/19/2009 11/19/2009 11/19/2009 11/17/2009 11/17/2009 11/17/2009 11/17/2009 11/17/2009 Inspection Historv Description 14 17 34 14 21 24 34 44 Frame/Steel/Bolting/Welding Interior Lath/Drywall Rough Electric Frame/Steel/Bolting/Welding Underground/Under Floor Rough/Topout Rough Electric Rough/Ducts/Dampers Act AP AP AP PA AP AP NR NR Insp PY PY PY PY PY PY PY PY Comments EsGil Corporation In Partners Hip with government for (Buifding Safety DATE: 1O/28/O9 a APPLICANT a JURIS. JURISDICTION: City of Carlsbad a PLAN REVIEWER a FILE PLAN CHECK NO.: 09-1594 SET: III PROJECT ADDRESS: 2744 Carlsbad Blvd Suite 1O4-1O6 PROJECT NAME: Ava-Jade Salon & Day Spa - TI XI The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: X3 Esgil Corporation staff did not advise the applicant that the plan check has been completed. Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Telephone #: Date contacted: (by: ) Fax #: Mail Telephone Fax In Person XI REMARKS: Applicant to hand carry the plans directly to the City of Carlsbad this does not assure a permit will be issued the city may have other corrections. By: Doug Moody Enclosures: EsGil Corporation D GA D EJ D PC LOG 9320 Chesapeake Drive, Suite 208 * San Diego, California 92123 + (858)560-1468 4 Fax (858) 560-1576 EsGil Corporation In Partners Hip with government for (Buififing Safety DATE: 1O/21 /O9 JURISDICTION: City of Carlsbad PLAN CHECK NO.: 09-1594 SET: II PROJECT ADDRESS: 2744 Carlsbad Blvd Suite 1O4-106 PROJECT NAME: Ava-Jade Salon & Day Spa - TI LJCANT ANREVIEWER a FILE The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. XI The applicant's copy of the check list has been sent to: Chris Meyers 22240 Monte Vista, Vista, CA 92084 Esgil Corporation staff did not advise the applicant that the plan check has been completed. Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Chris Meyers Telephone #: 760-419-0766 Date contacted: (°^i/^ (by$&) Fax #: ^JVIail Telephone Fax In Person REMARKS: C! k P \S d^£-h & Cx9 V . ^ ~ By: Doug Moody EsGil Corporation D GA D EJ Enclosures: PC 10/15/09 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858)560-1468 + Fax (858) 560-1576 City of Carlsbad 10/21/O9 09-1594 RECHECK CORRECTION LIST JURISDICTION: City of Carlsbad PLAN CHECK NO.: O9-1594 PROJECT ADDRESS: 2744 Carlsbad Blvd Suite 104-106 SET: II DATE PLAN RECEIVED BY ESGIL CORPORATION: 10/15/09 REVIEWED BY: Doug Moody DATE RECHECK COMPLETED: 1O/21/O9 FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the Building Code, Plumbing Code, Mechanical Code, Electrical Code and state laws regulating energy conservation, noise attenuation and disabled access. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department or other departments. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. The approval of the plans does not permit the violation of any state, county or city law. A. Please make all corrections on the original tracings and submit prints to: new complete sets of B. To facilitate rechecking, please identify, next to each item, the sheet of the plans upon which each correction on this sheet has been made and return this sheet with the revised plans. C. The following items have not been resolved from the previous plan reviews. The original correction number has been given for your reference. In case you did not keep a copy of the prior correction list, we have enclosed those pages containing the outstanding corrections. Please contact me if you have any questions regarding these items. D. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located on the plans. Have changes been made not resulting from this list? QYes QNo City of Carlsbad O9-1594 10/21/09 Please make all corrections on the original tracings, as requested in the correction list. Submit three sets of plans for commercial/industrial projects (two sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. These corrections are in response to items not fully addressed or as the result of information provided, the text in bold print indicates the unresolved issue. I. Each sheet of the plans must be signed by the person responsible for their preparation, even though there are no structural changes. Business and Professions Code. All sheets of the plans must be signed. 6. Please note in the general wiring notes on the plans "AC Cable is not allowed in A, B, E, H, F, M, S and I occupancies. NM cable is restricted (without City approval) to one and two family dwellings. Note on plans that an equipment ground conductor is to be installed in all flexible conduits". Please correct the plans note 3 on sheet 4 indicates the use of BX cable a type of AC cable that is not permitted in The City of Carlsbad. 10. Please show mechanical exhaust ventilation will be provided as shown in Table 4 4 of the UMC. Please revise the mechanical plans and the electrical plans to show and specify the exhaust fan. II. Please indicate the water connections to the pedicure chairs to be equipped with approved reduced pressure back-flow prevention. Please revise the plans to show both the hot and cold water supply line to be protected by reduced pressure backflow prevention. 12. Hot water supplied to a public use lavatory or any bathtub is limited to a maximum temperature potential of 120 degrees. Detail how this temperature limitation is achieved. Note: The water heater thermostat may not be used for compliance with this Code section. UPC 413.1 & UPC 414. Please show on the water line plans and indicate in the plumbing schedule the method for temperature limitation. 14. Please have the document author and the principle designer of the LTG-1-C form sign the imprinted document. The signed LTG forms must be imprinted on the plans City of Carlsbad 09-1594 1O/21/09 15. Provide automatic shut off controls for lighting as por Title 2<\, Part 6, Section 131(d). Please revise the electrical plans to be consistent with the LTG documents and show the automatic controls listed in the mandatory automatic controls portion of the form. 16. Please complete the LTG 1 C part 2 of 4 mandatory automatic controls portion of the LTG 1 C forms. See comment above. 17. Please have the principle designer check the appropriate box(s) and complete the Statement of Complianco System Acceptance section of tho LTG-1-C part 4 oH documents. Please indicate the equipment requiring testing and the person responsible for providing the required forms to the Building Inspector prior to final. To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please indicate: Yes a No a The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Doug Moody at Esgil Corporation. Thank you. EsGil Corporation In Partnership with government for (BuiCcfing Safety DATE: 1O/6/09 OAEguCANT JURISDICTION: City of Carlsbad OPEANREVIEWER a FILE PLAN CHECK NO.: 09-1594 SET: I PROJECT ADDRESS: 2744 Carlsbad Blvd Suite 104- 1O6 PROJECT NAME: Ava-Jade Salon & Day Spa - TI The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. XI The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. X3 The applicant's copy of the check list has been sent to: Chris Meyers 22240 Monte Vista, Vista, CA 92084 Esgil Corporation staff did not advise the applicant that the plan check has been completed. XJ Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Chris Meyers Telephone #: 760-419-0766 Date contacted :/Y^/4f(by4^3 Fax #: ^Mail y/Telephone\/ Fax In Person REMARKS: Cfo n'S 4 f^^+Q CO X- By: Doug Moody Enclosures: EsGil Corporationn GA n EJ n PC 9/29/09 9320 Chesapeake Drive, Suite 208 +• San Diego, California 92123 4 (858)560-1468 *• Fax (858) 560-1576 City of Carlsbad 09-1594 1O/6/09 PLAN REVIEW CORRECTION LIST TENANT IMPROVEMENTS PLAN CHECK NO.: 09-1594 OCCUPANCY: B TYPE OF CONSTRUCTION: Unknown ALLOWABLE FLOOR AREA: SPRINKLERS?: YES REMARKS: DATE PLANS RECEIVED BY JURISDICTION: 9/28/09 DATE INITIAL PLAN REVIEW COMPLETED: 10/6/09 JURISDICTION: City of Carlsbad USE: Salon ACTUAL AREA: 1590sf STORIES: 1 HEIGHT: OCCUPANT LOAD: 17 DATE PLANS RECEIVED BY ESGIL CORPORATION: 9/29/09 PLAN REVIEWER: Doug Moody FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the International Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Code sections cited are based on the 2007 CBC, which adopts the 2006 IBC. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 105.4 of the 2006 International Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans. City of Carlsbad 09-1594 1O/6/O9 Please make all corrections on the original tracings, as requested in the correction list. Submit three sets of plans for commercial/industrial projects (two sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. 1. Each sheet of the plans must be signed by the person responsible for their preparation, even though there are no structural changes. Business and Professions Code. 2. Provide a Building Code Data Legend on the Title Sheet. Include the following code information for each building proposed: * Type of Construction * Floor Area * Occupant Load 3. Provide a section view of all new interior partitions. Show: a) Method of attaching top plates to structure. Please clarify the lateral bracing of wall type 3 and wall type 2 (for wall type 2 how will a hinged conditioned be prevented). 4. Please provide a reflective ceiling plan. 5. Please provide the installation and listing information for the pedicure chairs. 6. Please note in the general wiring notes on the plans "AC Cable is not allowed in A, B, E, H, F, M, S and I occupancies. NM cable is restricted (without City approval) to one and two family dwellings. Note on plans that an equipment ground conductor is to be installed in all flexible conduits". 7. Please revise the electrical plans to show the dedicated receptacles for the pedicure chairs to be GFCI protected. 8. Please indicate if the mechanical system will be altered. If so please provide complete plans. Please provide the required MECH forms to show energy compliance. The MECH forms shall be signed and imprinted to the plans. City of Carlsbad 09-1594 10/6/09 9. When new rooms or spaces are constructed and the existing mechanical system is not to be altered other than relocation of existing duct work; please note or show mechanical ventilation will be provided capable of supplying the minimum rate of outside air required per minute per occupant as shown in Table 4-1 of the UMC. 10. Please show mechanical exhaust ventilation will be provided as shown in Table 4-4 of the UMC. 11. Please indicate the water connections to the pedicure chairs to be equipped with approved reduced pressure back-flow prevention. 12. Hot water supplied to a public use lavatory or any bathtub is limited to a maximum temperature potential of 120 degrees. Detail how this temperature limitation is achieved. Note: The water heater thermostat may not be used for compliance with this Code section. UPC 413.1 & UPC 414. 13. Provide a note on the plans: In showers and tub-shower combinations, control valves must be pressure balanced or thermostatic mixing valves. UPC Section 420.0. 14. Please have the document author and the principle designer of the LTG-1-C form sign the imprinted document. 15. Provide automatic shut-off controls for lighting as per Title 24, Part 6, Section 131 (d). 16. Please complete the LTG-1-C part 2 of 4 mandatory automatic controls portion of the LTG-1-C forms. 17. Please have the principle designer check the appropriate box(s) and complete the Statement of Compliance System Acceptance section of the LTG-1-C part 4 of 4 documents. 18. Please provide the required LTG-5-C form. Note : When alterations, structural repairs or modifications or additions are made to an existing building, that building, or portion of the building affected, is required to comply with all of the requirements for new buildings, per Section 1134B.2. These requirements apply as follows: a) Existing sanitary facilities that serve the remodeled area must be shown to comply with all accessibility features. 19. It is unclear from the plans if the restrooms servicing the tenant improvement are disabled accessible, please provide a dimensioned restroom plans showing the restroom to be accessible compliant. City of Carlsbad 09-1594 10/6/09 20. Please revise the plans to show a disabled accessible transaction counter located at a section of the main counter that is at least 36" long and no more than 28" to 34" high (flip-up or folding counters are only permitted in existing buildings when a finding of unreasonable hardship is found by the building Official). Section 1122B.5. 21. Show a level area, or landing for the doors to the utility and facial skin care rooms , per Section 1133B.2.4.2: a) >60" in the direction of door swing. 22. Please provide a door schedule; indicate the type of hardware and reference the doors on the floor plan. 23. Please revise the plans to show the sink in the utility room to provide the following: a) A clear floor space at least 30"x 48" shall be provided for forward approach. b) The clear space shall extend a maximum of 19" underneath the sink. c) The accessible sink shall be a maximum of 6 W deep. d) The sink shall be mounted with the counter or rim no higher than 34" e) Knee clearance that is at least 27" high, 30" side and 19" underneath the sink shall be provided. f) Hot water and drain shall be insulated. g) There shall be no sharp or abrasive surfaces under sinks. 24. If showers are proposed, show or note compliance with the following requirements, per Section 1115B.4.4: a) Size and Clearance. Accessible showers shall comply with one of the following: i) Roll-in shower 60 inches minimum in width between wall surfaces and 30 inches in depth with a full opening width on the long side. Shower compartment size and clear floor space shall comply with Figure 11B-2A. ii) Alternate roll-in shower 60 inches minimum in width between the wall surfaces and 36 inches in depth with an entrance opening width of 36 inches minimum. Shower compartment size and clear floor space shall comply with Figure 11B-2B. iii) Alternate roll-in shower 60 inches minimum in width between the wall surfaces and 36 inches in depth as long as the entrance opening width is a minimum of 36 inches. Shower compartment size and clear floor space shall comply with Figure 11B-2C. b) Threshold in roll-in type showers shall be 1/2 inch in high maximum and shall comply with Section 1124B.2. City of Carlsbad 09-1594 10/6/09 c) Orientation. Where within the same functional area, two or more accessible showers are provided, there shall be at least one shower constructed opposite hand from the other or others (i.e., one left-hand control versus right-hand control). d) Water controls shall be of a single-lever design, operable with one hand, and shall not require grasping, pinching or twisting of the wrist. The center line of the controls shall be located at 40 inches above the shower floor. i) Controls in a 60-inch minimum by 30-inch minimum shall be located on the back wall of the compartment adjacent to the seat and the centerline of the controls shall be within a range of no less than 19 inches and no more than 27 inches from the seat wall as shown in Figure 11B-2A. ii) Controls in a 60-inch minimum by 36-inch minimum alternate roll-in shower shall be located on the side wall of the compartment adjacent to the seat and the centerline of the controls shall be within a range of no less than 19 inches and no more than 27 inches from the seat wall as shown in Figure 11B-2B. iii) Controls in a 60-inch minimum by 36-inch minimum alternate roll-in shower with optional enclosure shall be located on the back wall of the compartment adjacent to the seat and the centerline of the controls shall be within a range of no less than 19 inches and no more than 27 inches from the seat wall as shown in Figure 11B-2C. e) A flexible hand-held shower unit is required with at least a hose 60 inches long that can be both used as a fixed shower head and hand held. This unit shall be mounted such that the top of the mounting bracket is a maximum of 48 inches above the shower floor. i) The hand held sprayer unit a 60-inch minimum by 30-inch minimum shall be located on the back wall of the compartment adjacent to the seat and the centerline of the controls shall be within a range of no less than 19 inches and no more than 27 inches from the seat wall as shown in Figure 11B-2A ii) The hand held sprayer unit in a 60-inch minimum by 36-inch minimum alternate roll-in shower shall be located on the side wall of the compartment adjacent to the seat and the centerline of the controls shall be within a range of no less than 19 inches and no more than 27 inches from the seat wall as shown in Figure 11B-2B. iii) The hand held sprayer unit in a 60-inch minimum by 36-inch minimum alternate roll-in shower with optional enclosure shall be located on the back wall of the compartment adjacent to the seat and the centerline of the controls shall be within a range of no less than 19 inches and no more than 27 inches from the seat wall as shown in Figure 11B-2C. f) Two wall-mounted heads may be installed in lieu of the hand-held unit in areas subject to excessive vandalism. (Except within guest room and suites City of Carlsbad 09-1594 10/6/09 of hotels, motels and similar transient lodging establishments) Each shower head shall be installed so that it can be operated independently of the other and shall have swivel angle adjustments both vertically and horizontally. One head shall be located at a height of 48 inches above the floor. g) The floor slope shall be a maximum of 2% in any direction. Where drains are provided, the grate shall have openings % inch maximum and located flush with the floor surface. h) Indicate on the plans a folding seat, located on the wall adjacent to the controls, 18" above the floor and shall not extend more than Q inches from the wall. The seat dimensions and mounting position shall comply with Figures 11B-2A, 11B-2B, 11B-2C. i) Grab bars complying with Section 1115B.4.4.8 shall be located: i) On walls adjacent to and opposite the seat, ii) Mounted >33" but <36" above the shower floor. iii) Grab bars shall not extend into that portion of the wall over the seat. See Figures 11B-2A, 11B-2B, 11B-2C j) The soap dish when provided shall be located on the control wall <40" above the shower floor and within reach limits from the seat. Section 1115B.4.4.9. k) Enclosures when provided for shower compartments shall not obstruct controls or obstruct transfer from wheelchairs onto the shower seat. To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please indicate: Yes a No a The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Doug Moody at Esgil Corporation. Thank you. City of Carlsbad 09-1594 10/6/09 [DO NOT PAY-THIS IS NOT AN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION: City of Carlsbad PLAN CHECK NO.: O9-1594 PREPARED BY: Doug Moody DATE: 10/6/09 BUILDING ADDRESS: 2744 Carlsbad Blvd Suite 104-106 BUILDING OCCUPANCY: B TYPE OF CONSTRUCTION: Unknown BUILDING PORTION Tl Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code AREA (Sq. Ft.) 1590 cb Valuation Multiplier 34.37 By Ordinance Reg. Mod. VALUE ($) 54,648 54,648 $441.18 Plan Check Fee by Ordinance Type of Review: [2 I I Repetitive FeeRepeats Complete Review D Other t—I Hourly EsGil Fee Structural Only Hr. $286.77 $247.06 Comments: Sheet 1 of 1 macvalue.doc + PLANNING/ENGINEERING APPROVALS PERMIT NUMBER CB ADDRESS DATE A 0 RESIDENTIAL TENANT IMPROVEMENT RESIDENTIAL ADDITION MINOR (<$17,000.00) PLAZA CAMINO REAL CARLSBAD COMPANY STORES VILLAGE FAIRE COMPLETE OFFICE BUILDING OTHER PLANNER ENGINEER DATE DATE Docs/Misforms/Planning Engineering Approvals ! s a s 0 D 0 S C Cmm Q- Q_ Q. D D D D D D D EH CH CH REDEVELOPMENT DEPARTMENT BUILDING PLAN CHECK REVIEW CHECKLIST Plan Check No. CB Planner )/£ APN: Address Sii_V/V Phone (760) 434- T.uType of Project & Use: Zoning: W f^- General Plan: W CFD (in/out) #_Date of participation: Net Project Density:DU/AC Facilities Management Zone: Remaining net dev acres: Circle One (For non-residential development: Type of land used created by this permit: ) Legend: 1X1 Item Complete Environmental Review Required: DATE OF COMPLETION: Item incomplete - Needs your action YES NOY* TYPE Compliance with conditions of approval? If not, state conditions which require action. Conditions of Approval: Discretionary Action Required: APPROVAL/RESO. NO. PROJECT NO. YES NO TYPE DATE OTHER RELATED CASES: Compliance with conditions or approval? If not, state conditions which require action. Conditions of Approval: N0 Coastal Zone Assessment/Compliance Project site located in Coastal Zone?YES_ CA Coastal Commission Authority? YES_ If California Coastal Commission Authority: Contact them at - 7575 Metropolitan Drive, Suite 103, San Diego CA 92108-4402; (619) 767-2370 Determine status (Coastal Permit Required or Exempt): Habitat Management Plan Data Entry Completed? YES NO V. If property has Habitat Type identified in Table 11 of HMP, complete HMP Permit application and assess fees in Permits Plus (A/P/Ds, Activity Maintenance, enter CB#, toolbar, Screens, HMP Fees, Enter Acres of Habitat Type impacted/taken, UPDATE!) Inclusionary Housing Fee required:YES NO (Effective date of Inclusionary Housing Ordinance - May 21, 1993.) Data Entry Completed? YES NO (A/P/Ds, Activity Maintenance, enter CB#, toolbar, Screens, Housing Fees, Construct Housing Y/N, Enter Fee, UPDATE!) H:\ADMIN\COUNTER\BldgPlnchkRevChklst Rev 3/06 Site Plan: I I I I Provide a fully dimensional site plan drawn to scale. Show: North arrow, property lines, easements, existing and proposed structures, streets, existing street improvements, right-of- way width, dimensional setbacks and existing topographical lines (including all side and rear yard slopes). Provide legal description of property and assessor's parcel number. HDD CD CD a n n HDD HDD Q D D Policy 44 - Neighborhood Architectural Design Guidelines 1. Applicability: YES NO 2. Project complies YES NO Zoning: ^1 }&, 1. Setbacks: Front: Interior Side: Street Side: Rear: Top of slope: Required Required Required Required Required 2. Accessory structure setbacks: Front: Interior Side: Street Side: Rear: Structure separation: 3. Lot Coverage: 4. Height: 5. Parking: Required Required Spaces Required Shown Shown Shown Shown Shown Required Required Required Required Required Shown Shown Shown Shown Shown Shown Shown Shown (breakdown by uses for commercial and industrial projects required) Residential Guest Spaces Required Shown Additional Comments B\fti,f>i^L P»9T£.o OK TO ISSUE AND ENTERED APPROVAL INTO COMPUTER H:\ADMIN\COUNTER\BldgPlnchkRevChklst DATE Rev 3/06 September 29, 2009 TO: BUILDING DEPARTMENT FROM: Assistant Planner, Redevelopment Department CB091594 I have reviewed the building plans for the above referenced project. The Housing and Redevelopment Department supports the tenant improvements for a new salon at 2744 Carlsbad Blvd., Ste. 104 & 106. This information was entered into Permits Plus on September 29, 2009. If you have any questions, please contact me at x2813. AUSTIN SILVA Carlsbad Fire Department Plan Review Requirements Category: TI, COMM Date of Report: 10-21 -2009 Reviewed by: 7X~ Name: HUNT KENNETH Address: 2744 CARLSBAD BLVD CARLSBAD CA ^ £A 92008 Permit #: CB091594 Job Name: JADE SALON- 1590 SF SALON TO Job Address: 2744 CARLSBAD BL CBAD St: 106 lt!view is incomplete. Alibis time, this office cannot adequately conduct a review tr> ^^t(arrpi'im uniinill'llii ili Hi \[\[\Y\\ ilil ..... li iniTnhMh»i«|jJiiiii n carefully all commenJ^fcaCffeaPlease resubmit the necessary plans and/or specifications, with changes~"cT&oded ' ' , to this office fo^^view and approval. Conditions: Cond: CON0003691 [MET] ***Approval with Conditions*** *** Add the following to nots on first page*** 1. Add CFC, 2007 to General Notes section. 2. "(If required) Complete plans and specifications for fire alarm systems, fire extinguishing systems, including automatic sprinklers and wet and dry standpipes; inert/halocarbon systems and other special types of automatic fire protection systems and appurtenances thereto shall be submitted to Carlsbad Fire Department for review and approval PRIOR to installation. (CFC 901.2)" Entry: 10/21/2009 By: cwong Action: AP SAN DIEGO REGIONAL HAZARDOUS MATERIALS QUESTIONNAIRE OFFICE USE ONLY UPFP# HV# BP DATE Business Name Business Contact Telephone # Project Address City Zip Code APN# Mailing Address City State Zip Code Plan File# Project Contact Telephone # Oft) 77s- The following questions represent the facility's activities, NOT the specific project description. PART I: FIRE DEPARTMENT - HAZARDOUS MATERIALS DIVISION: OCCUPANCY CLASSIFICATION: Indicate by circling the item, whether your business will use, process, or store any of the following hazardous materials. If any of the items are circled, applicant must contact the Fire Protection Agency with jurisdiction prior to plan submittal. 5. Organic Peroxides 9. 6. Oxidizers 10. 7. Pyrophorics 11. 8. Unstable Reactives 12. 1. Explosive or Blasting Agents 2. Compressed Gases 3. Flammable/Combustible Liquids 4. Flammable Solids Water Reactives Cryogenics Highly Toxic or Toxic Materials Radioactives 13. Corrosives 14. Other Health Hazards 15. None of These. PART II: SAN DIEGO COUNTY DEPARTMENT OF ENVIRONMENTAL HEALTH - HAZARDOUS MATERIALS DIVISIONS (HMD): If the answer to any of the questions is yes, applicant must contact the County of San Diego Hazardous Materials Division, 1255 Imperial Avenue, 3™ floor, San Diego, CA 92101. Call (619) 338-2222 prior to the issuance of a building permit. FEES ARE YES 1. D2. n 3. D 4. D5. ne. n REQUIRED. Expected Date of Occupancy: / / NO B. Is your business listed on the reverse side of this form? (check all that apply). HL Will your business dispose of Hazardous Substances or Medical Waste in any amount? fjfl Will your business store or handle Hazardous Substances in quantities equal to or greater than 55 gallons, 500 pounds, 200 cubic feet, or carcinogens/reproductive toxins in any quantity? tWill your business use an existing or install an underground storage tank? Will your business store or handle Regulated Substances (CalARP)? Will your business use or install a Hazardous Waste Tank System (Title 22, Article 10)? D CalARP Exempt Date Initials D CalARP Required Date Initials D CalARP Complete Date Initials PART III: SAN DIEGO COUNTY AIR POLLUTION CONTROL DISTRICT: If the answer to any of the questions below is yes, applicant must contact the Air Pollution Control District (APCD), 10124 Old Grove Road, San Diego, CA 92131-1649, telephone (858) 586-2600 prior to the issuance of a building or demolition permit. Note: if the answer to questions 3 or 4 is yes, applicant must also submit an asbestos notification form to the APCD at least 10 working days prior to commencing demolition or renovation, except clenioljliorLor renovation of residential structures of four units or less. Contact the APCD for more information. 1. YES D 2. D 3. 4. Dn NO B 0. Will the subject facility or construction activities include operations or equipment that emit or are capable of emitting an air contaminant? (See the APCD factsheet at http://www.sdapcd.org/info/facls/permits.pdf, and the list of typical equipment requiring an APCD permit on the reverse side of this from. Contact APCD if you have any questions). (ANSWER ONLY IF QUESTION 1 IS YES) Will the subject facility be located within 1,000 feet of the outer boundary of a school (K through 12)? (Public and private schools may be found after search of the California School Directory at http://www.cde.ca.gov/re/sd/: or contact the appropriate school district). Will there be renovation that involves handling of any friable asbestos materials, or disturbing any material that contains non-friable asbestos? Will there be demolition involving the removal of a load supporting structural member? Briefly describe business activities:Briefly describe proposed project: I declare under penalty of perjury that to the best of my knowledge and belief thajesp made.herein are true and correct. Name of owner or Authorized Agent Signature of Owner or Authorized Agent 10 I Date FOR OFFICIAL USE ONLY:FIRE DEPARTMENT OCCUPANCY CLASSIFICATION:, BY:DATE: EXEMPT OR NO FURTHER INFORMATION REQUIRED COUNTY-HMD APCD RELEASED FOR BUILDING PERMIT BUT NOT FOR OCCUPANCY COUNTY-HMD APCD RELEASED FOR OCCUPANCY COUNTY-HMD APCD HM-9171 (04/07)County of San Diego- DBH - Hazardous Materials Division