HomeMy WebLinkAbout2744 CARLSBAD BLVD; 100; CB100319; Permit04-15-2010 City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Commercial/Industrial Permit Permit No: CB100319 Building Inspection Request Line (760) 602-2725 Job Address: Permit Type: Parcel No: Valuation: Occupancy Group: Project Title: Applicant: 2744 CARLSBAD BL CBAD St: 100 Tl Sub Type: COMM 2031722701 Lot #: 0 Status: $73,565.00 Construction Type: 5A Applied: Reference #: Entered By: IT'S A GRIND - COMBINE SUITES Plan Approved: 100 & 102 (PREVIOUSLY DONE AS A SPEC SUIT)TO BECOME Issued: Inspect Area: Plan Check#: Owner: ISSUED 02/23/2010 RMA 04/15/2010 04/15/2010 DROGO DEVELOPMENT DBA IT'S A GRIND STE 200 2744 CARLSBAD BLVD 92008 310593-3534 ANASTASI DEVELOPEMENT CO, LLC 1200 AVIATION BL #203 REDONDO BEACH 90278 Building Permit Add'l Building Permit Fee Plan Check Add'l Plan Check Fee Plan Check Discount Strong Motion Fee Park Fee LFM Fee Bridge Fee BTD #2 Fee BTD #3 Fee Renewal Fee Add'l Renewal Fee Other Building Fee Pot. Water Con. Fee Meter Size Add'l Pot. Water Con. Fee Reel. Water Con. Fee Green Bldg Stands (SB1473) Fee Fire Expedited Plan Review $527.63 $0.00 $342.96 $0.00 $0.00 $15.45 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $1.00 7? Meter Size Add'l Reel. Water Con. Fee Meter Fee SDCWA Fee CFD Payoff Fee PFF (3105540) PFF (4305540) License Tax (3104193) License Tax (4304193) Traffic Impact Fee (3105541) Traffic Impact Fee (4305541) PLUMBING TOTAL ELECTRICAL TOTAL MECHANICAL TOTAL Master Drainage Fee Sewer Fee Redev Parking Fee Additional Fees HMP Fee TOTAL PERMIT FEES $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $55.00 $35.00 $30.50 $0.00 $0.00 $0.00 $272.50 $1,280.04 Total Fees:$1,280.04 Total Payments To Date:M 'W,Balance Due:$0.00 Inspector: FINAL APPROVAL Date: 7'/£ ' /D Clearance: NOTICE: Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired. 04-07-2010 City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Commercial/Industrial Permit Permit No: CB060369 Building Inspection Request Line (760) 602-2725 Job Address: Permit Type: Parcel No: Valuation: Occupancy Group: Project Title: 2744 CARLSBAD BL CBAD St: 102 Tl Sub Type: 2031722701 Lot#: $29,225.00 Construction Type: Reference #: ANASTASI 835 SF SHELL TO RETAIL, SPEC SUITE COMM 0 NEW Applicant: LAUGHLIN GREG 3210 HARDING ST CARLSBAD CA 92008 Status: Applied: Entered By: Plan Approved: Issued: Inspect Area: Plan Check*: FINAL 02/14/2006 MDP 05/10/2006 05/10/2006 PY Owner: ANASTASI DEVELOPMENT 511TORRANCEBLVD REDENDO BEACH CA 92008 Building Permit Add'l Building Permit Fee Plan Check Add'l Plan Check Fee Plan Check Discount Strong Motion Fee Park Fee LFM Fee Bridge Fee BTD #2 Fee BTD #3 Fee Renewal Fee Add'l Renewal Fee Other Building Fee Pot. Water Con. Fee Meter Size Add'l Pot. Water Con. Fee Reel. Water Con. Fee Green Bldg Stands (SB1473) Fee Fire Expedited Plan Review $242.99 Meter Size $0.00 Add'l Reel. Water Con. Fee $157.94 Meter Fee $0.00 SDCWA Fee $0.00 CFD Payoff Fee $6.14 PFF (3105540) $0.00 PFF (4305540) $0.00 License Tax (3104193) $0.00 License Tax (4304193) $0.00 Traffic Impact Fee (3105541) $0.00 Traffic Impact Fee (4305541) $0.00 PLUMBING TOTAL $0.00 ELECTRICAL TOTAL $0.00 MECHANICAL TOTAL $0.00 Master Drainage Fee Sewer Fee $0.00 Redev Parking Fee $0.00 Additional Fees ?? HMP Fee ?? TOTAL PERMIT FEES $0.00 $0.00 $0.00 $0.00 $531.90 $490.98 $0.00 $0.00 $0.00 $0.00 $48.00 $35.00 $30.50 $0.00 $0.00 $0.00 $0.00 $1,543.45 Total Fees:$1,543.45 Total Payments To Date:$1,543.45 Balance Due:$0.00 Inspector: FINAL APPROVAL Date:Clearance: NOTICE: Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired. CITY OF CARLSBAD Building Permit Application 1635 Faraday Ave., Carlsbad, CA 92008 760-602-2717 / 2718 / 2719 Fax: 760-602-8558 www.carlsbadca.eov CONTACT NAME'ftf Different Fom Applicant) (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law (Chapter 9, commending with Section 7000 of Division 3 of theBusiness and Professions Code) or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for? " —••-'--*-" '•-—* —civil penalty of not more than five hundred dollars ($500)).or a permit subjects the applicant to a Workers' Compensation Declaration: / hereby affirm under penalty of perjury one of the following declarations: CJ I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. L~l I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Insurance Co. ^>T~tyl^t£ ^LTVv><^ _ Policy No. ^y>»,c3 _ Expiration Date This section need not be completed if the permit is for one hundred dollars ($100) or less. O Certificate of Exemption: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. WARNING: Failure to secure workers' compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars (&100.000), in addition to the cost of compensation, damages as provided for in Section 3706 of the Labor code, interest and attorney's fees. J&£ CONTRACTOR SIGNATURE [~| AGENT DATE / hereby affirm that I am exempt from Contractor's License Law for the following reason: O I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder mil have the burden of proving that he did not build or improve for the purpose of sale). n I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractors) licensed pursuant to the Contractor's License Law). D I am exempt under Section Business and Professions Code for this reason: 1.1 personally plan to provide the major labor and materials for construction of the proposed property improvement, rj Yes D No 2.1 (have / have not) signed an application for a building permit for the proposed work. 3.1 have contracted with the following person (firm) to provide the proposed construction (include name address / phone / contractors' license number): 4.1 plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone / contractors' license number): 5.1 will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone / type of work): vfifpROPERTY OWNER SIGNATURE DAGENT DATE Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505,25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? O Yes O No Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? CD Yes O No Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? a Yes d No IF ANY OF THE ANSWERS ARE YES, / EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. I hereby affirm that there is a construction lending agency for the performance of the work this permit is issued (Sec. 3097 (i) Civil Code). Lender's Name Lender's Address I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all City ordinances and State laws relating to building construction. I hereby authorize representative of the City of Cartebad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: An OSHA permit is required for excavations over 5'0" deep and demolition or construction of structures over 3 stories in height. EXPIRATION: E 180 days from the date of such permit orjfjjS! buidinr^ufumtV authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days (Section 106.4.4 Uniform Building Code). .-^APPLICANT'S SIGNATUR DATE CITY OF CARLSBAD UNSCHEDULED BUILDING INSPECTIONINSP B EJ4 DeveloDment Services Building Division 1635 Faraday Avenue DATE: PERMIT #:I oo 51 JOB ADDRESS: DESCRIPTION: INSPECTOR: CONTACT: PHONE #: /PC) CODE DESCRIPTION ACT COMMENTS Bldg Inspection Form Page 1 of 1 Rev. 06/09 EsGil Corporation In (Partnership with government for <Buifd~ing Safety DATE: 4/6/10 a APPLICANT a JURIS. JURISDICTION: City of Carlsbad a PLAN REVIEWER a FILE PLAN CHECK NO.: 10-0319 SET: III PROJECT ADDRESS: 2744 Carlsbad Blvd Suite 100 PROJECT NAME: It's a Grind - TI The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. A] The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: XI Esgil Corporation staff did not advise the applicant that the plan check has been completed. Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Telephone #: Date contacted: (by: ) Fax #: Mail Telephone Fax In Person XI REMARKS: Applicant approved to hand carry plans back to the City. Note: The following items are deferred items: dryer, water heater, and fireplace flue and this stipulation added to the City set of plans Title Sheet. Additionally the City set should have the following sheets already slip- sheeted: A0.1, A6.4, P1, and P2 (or at the City). By: Eric Jensen Enclosures: EsGil Corporation D GA D EJ D PC 4/6/OTC 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858)560-1468 4 Fax (858) 560-1576 EsGil Corporation In Partnership with government for (Buiftfing Safety DATE: 4/2/10 a APPLICANT JURISDICTION: City of Carlsbad a PLAN REVIEWER a FILE PLAN CHECK NO.: 10-0319 SET: II PROJECT ADDRESS: 2744 Carlsbad Blvd Suite 100 PROJECT NAME: It's a Grind - TI The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. XI The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. XI The applicant's copy of the check list has been sent to: Sam Drogo 2744 Carlsbad Blvd Suite 200, Carlsbad, CA 92008 E-mail: drgo@msn.com Esgil Corporation staff did not advise the applicant that the plan check has been completed. XI Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Sam Drogo Telephone #: 310-593-3534 Date contacted: f I zJ/o (by: (^ ) Fax #: 760-720-0597 £ Mail--^ Telephone Fax^ In Person REMARKS: By: Doug Moody Enclosures: EsGil Corporationn GA n EJ n PC 4/1/10 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 * (858)560-1468 + Fax (858) 560-1576 City of Carlsbad 1O-0319 4/2/10 Please make all corrections on the original tracings, as requested in the correction list. Submit three sets of plans for commercial/industrial projects (two sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. These corrections are in response to items not fully addressed or as the result of information provided, the text in bold print indicates the unresolved issue. 1. Provide a Building Code Data Legend on the Title Sheet. Include the following code information for each building proposed: » Occupancy Classification(s) A2 Per Will Foss deferred to City. * Occupant Load to be 58 4. Each door in a means of egress from an occupancy of Group A having an occupant load of 50 or more shall not be provided with a latch or lock unless it is panic hardware. Section 1008.1.9. Per Will Foss deferred to City. 6. Please provide the listing and installation information for the new fire place. Please provide complete plans and details to the flue termination and the required clearances. Please clarify the plans it appears this is a multistory building with a 1 hour floor/ceiling assembly? Please provide a section and elevation showing the required clearance per the manufacturer's recommendations to the overhang, opening to the residential units, show the outside air duct to extend to the exterior etc. 7. Provide complete plumbing plans, including: a) Complete drain, waste and vent plans. Please clarify the fixture schedule it appears a clothes washer is to be installed (sanitary plan note 1). Please provide the manufacturer's specifications and installation recommendations. b) Provide gas line plans and calculations, showing pipe lengths and gas demands. City of Carlsbad 10-0319 4/2/10 8. Provide separate restroom facilities for each sex as per UPC, Section 412.1. Per Will Foss deferred to City 9. Provide the following information concerning the water heater: • Show water heater size, type and location on plans. UPC 501.0 Please provide the water heater specification to show it to be a direct vent water heater and show the venting and combustion air requirements. • Provide combustion air design: Show opening sizes and routing of ducts. UPC 507.0. No information provided. • Detail the water heater vent installation: Size, routing, slope, and termination location (Minimum 8' from vertical surfaces). UPC 510.0 Please clarify the plans it appears the water heater exhaust is connected to the restroom exhaust fan duct? Please provide evidence (copy of the original City approved construction documents for the duct installation) showing the ducting to be rated, installed and terminated in compliance with requirements for a water heater. To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please indicate: Yes Q No a The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Doug Moody at Esgil Corporation. Thank you. EsGil Corporation In (Partnership with government for Quitting Safety DATE: 3/4/10 JURISDICTION: City of Carlsbad a PLAN REVIEWER a FILE PLAN CHECK NO.: 1O-O319 SET: I PROJECT ADDRESS: 2744 Carlsbad Blvd Suite 100 PROJECT NAME: It's a Grind - TI The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: Sam Drogo 2744 Carlsbad Blvd Suite 200, Carlsbad, CA 92008 E-mail: drqo@msn.com Esgil Corporation staff did not advise the applicant that the plan check has been completed. XJ Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Sam Drogo Telephone #: 310-593-3534 Date contacted: 3/V If* (by: f- ) Fax #: 760-720-0597 ^Ma\\ ^Telephone ^ Fax In Person REMARKS: By: Doug Moody Enclosures: EsGil Corporation D GA D EJ D PC 2/25/10 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858)560-1468 + Fax (858) 560-1576 City of Carlsbad 3/4/1O 10-0319 PLAN REVIEW CORRECTION LIST TENANT IMPROVEMENTS PLAN CHECK NO.: 10-0319 OCCUPANCY: A2 TYPE OF CONSTRUCTION: VA ALLOWABLE FLOOR AREA: SPRINKLERS?: YES REMARKS: DATE PLANS RECEIVED BY JURISDICTION: 2/23/10 DATE INITIAL PLAN REVIEW COMPLETED: 3/4/10 JURISDICTION: City of Carlsbad USE: Restaurant ACTUAL AREA: 1580 STORIES: 1 HEIGHT: OCCUPANT LOAD: 58 DATE PLANS RECEIVED BY ESGIL CORPORATION: 2/25/10 PLAN REVIEWER: Doug Moody FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the International Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Code sections cited are based on the 2007 CBC, which adopts the 2006 IBC. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 105.4 of the 2006 International Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e.. plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans. City of Carlsbad 10-0319 3/4/1O Please make all corrections on the original tracings, as requested in the correction list. Submit three sets of plans for commercial/industrial projects (two sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. 1. Provide evidence of Health Department approval (for restaurants), where regulated by the local Health Department. 2. Provide a Building Code Data Legend on the Title Sheet. Include the following code information for each building proposed: • Occupancy Classification(s) A2 • Occupant Load to be 58 3. Please provide notes on the plans to show the suspended ceilings in Seismic Design Categories D, E & F comply with ASCE 7-05 Section 13.5.6.2.1 as follows: a) All ceilings shall use a Heavy Duty T-bar grid system. b) The width of the perimeter supporting closure angle shall be not less than 2 inches. c) In each orthogonal horizontal direction, one end of the ceiling grid shall be attached to the closure angle. d) The other end in each horizontal direction shall have a %" clearance from the wall and shall rest upon and be free to slide on a closure angle or a listed assembly. e) Ceilings without rigid bracing must have 2" oversize trim rings for sprinklers and other ceiling penetrations. 4. Each door in a means of egress from an occupancy of Group A having an occupant load of 50 or more shall not be provided with a latch or lock unless it is panic hardware. Section 1008.1.9. 5. Elevation changes less than 12" in the means of egress shall be made by slope surfaces. Sloped surfaces greater than 1 unit vertical in 20 units horizontal shall comply as ramps. Please revise the plans to show the step in the seating area and in the service area to be ramps. Section 1003.5. City of Carlsbad 1O-0319 3/4/10 6. Please provide the listing and installation information for the new fire place. Please provide complete plans and details to the flue termination and the required clearances. Please clarify the plans it appears this is a multistory building with a 1 hour floor/ceiling assembly? 7. Provide complete plumbing plans, including: a) Complete drain, waste and vent plans. b) Provide complete water line sizing plans and calculations, including the water pressure, pressure losses, water demands, and developed pipe lengths. UPC Section 610.0 c) Provide gas line plans and calculations, showing pipe lengths and gas demands. 8. Provide separate restroom facilities for each sex as per UPC, Section 412.1. 9. Provide the following information concerning the water heater: • Show water heater size, type and location on plans. UPC 501.0 • Show that water heater is adequately braced to resist seismic forces. Provide two straps. One strap at top 1/3 of the tank and one strap at bottom 1/3 of the tank. UPC 508.2 • Show P & T valve on water heater and detail the drain routing to the exterior. It may not be installed upwards from the valve. UPC 506.2/608.3 • Provide combustion air design: Show opening sizes and routing of ducts. UPC 507.0 • Detail the water heater vent installation: Size, routing, slope, and termination location (Minimum 8' from vertical surfaces). UPC 510.0 • An expansion tank or other approved device is required if system pressure relief is not available due to the installation of backflow devices or certain pressure regulators. Please address. UPC 608.3 10. Please indicate if the mechanical system will be altered. If so please provide complete plans. Please provide the required MECH forms to show energy compliance. The MECH forms shall be signed and imprinted to the plans. 11. Provide mechanical plans, showing existing and proposed HVAC equipment, ducts and access to equipment. 12. Please provide panel schedules, indicate new and existing loads. 13. Please indicate on the plans the location of the electrical panel and detail the required working clearance. 14. Please note in the general wiring notes on the plans "AC Cable is not allowed in A, B, E, H, F, M, S and I occupancies. NM cable is restricted (without City City of Carlsbad 1O-0319 3/4/10 approval) to one and two family dwellings. Note on plans that an equipment ground conductor is to be installed in all flexible conduits". 15. Please imprint on the plans the energy documentation provided. 16. Please complete the LTG-1-C part 2 of 3 mandatory automatic controls portion of the LTG-1-C forms. 17. Please provide the required LTG-9-C form for the track lighting. 18. The allowable slope for an accessible ramp is ^1:12 (8.33%), per Section 1133B.5.3. Please clarify the plans the notes indicate the elevation change to be 6 %" yet the ramp is only 48" in length resulting in a ramp of 14%. Section 1133B.5.1. 19. Show handrails at each side of ramp(s) which are shown to be >1:20 (5%) in slope, per Section 1133B.5.5. 20. Show that handrails are >1 %" but ^114" in any cross sectional dimension. Additionally, show that the handrails are placed a >11/2M from any wall, per Section 1133B.5.5. 21. Show or note that handrails meet the following requirements, per Section 1133B.5.5: a) Are continuous. b) Are to be located >34" but ^38" above the ramp surface. c) Extend >12" beyond both the top and bottom landings. d) Ends are to be returned. 22. Floors of a given story shall be a common level throughout, or shall be connected by pedestrian ramps, elevators or lifts (no steps). Section 1120B.1. 23. It appears from the plans if the restrooms servicing the tenant improvement are not disabled accessible, please provide a dimensioned restroom plans showing the restroom to be accessible compliant. 24. Show that the water closet is located in a space, per Section 1115B.3.2.3, which provides: a) A clear space in front of the water closet measuring 60" wide by 48" in front. Section 1115B.4.1.2. The depth shown will not provide the required 48". To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. City of Carlsbad 10-0319 3/4/10 Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please indicate: Yes a No a The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Doug Moody at Esgil Corporation. Thank you. City of Carlsbad 1O-O319 3/4/10 [DO NOT PAY- THIS IS NOT AN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION: City of Carlsbad PLAN CHECK NO.: 10-0319 PREPARED BY: Doug Moody DATE: 3/4/10 BUILDING ADDRESS: 2744 Carlsbad Blvd Suite 100 BUILDING OCCUPANCY: A2 TYPE OF CONSTRUCTION: VA BUILDING PORTION Tl Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code AREA ( Sq. Ft.) 1580 cb Valuation Multiplier 46.56 By Ordinance Reg. Mod. VALUE ($) 73,565 73,565 Bldg. Permit Fee by Ordinance Plan Check Fee by Ordinance Type of Review: I ] Repetitive FeeRepeats 0 Complete Review D Other i—j Hourly EsGil Fee Structural Only Hr. @ $527.63 $342.96 $295.47 Comments: Sheet 1 of 1 macvalue.doc + PLANNING/ENGINEERING APPROVALS PERMIT NUMBER CB ADDRESS DATE RESIDENTIAL RESIDENTIAL ADDITION MINOR (<$17,000.00) TENANT IMPROVEMENT PLAZA CAMINO REAL CARLSBAD COMPANY STORES VILLAGE FAIRE COMPLETE OFFICE BUILDING OTHER PLANNER ENGINEER -fr DATE DATE C 66 3 o/O / Docs/Misforms/Planning Engineering Approvals February 25, 2010 TO: BUILDING DEPARTMENT FROM: Assistant Planner, Redevelopment Department CB100319 I have reviewed the building plans for the above referenced project. The Housing and Redevelopment Department supports issuing the building permit for the tenant improvement at 2744 Carlsbad Blvd, Ste. 100. This information was entered into Permits Plus on February 25, 2010. If you have any questions, please contact me at x2813. AUSTIN SILVA £ S £ £• Z5 a _ O. Q- Q. n n n n n REDEVELOPMENT DEPARTMENT BUILDING PLAN CHECK REVIEW CHECKLIST Plan Check No. CB Planner fl. Sil» APN: Address Phone (760) 434- Type of Project & Use: TJ- Zoning: VP- General Plan:_ CFD (in/out) #_Date of participation: Circle One Net Project Density:,DP/AC \/_Facilities Management Zone: Remaining net dev acres: (For non-residential development: Type of land used created by this permit: _ ) Legend: [XI Item Complete I I Item Incomplete - Needs your action Environmental Review Required: YES _ NCT>C TYPE _ DATE OF COMPLETION: _ Compliance with conditions of approval? If not, state conditions which require action. Conditions of Approval: Discretionary Action Required: APPROVAL/PESO. NO. PROJECT NO. YES NO TYPE DATE OTHER RELATED CASES: Compliance with conditions or approval? If not, state conditions which require action. Conditions of Approval: Coastal Zone Assessment/Compliance Project site located in Coastal Zone?YESJX_ CA Coastal Commission Authority? YES NO If California Coastal Commission Authority: Contact them at - 7575 Metropolitan Drive, Suite 103, San Diego CA 92108-4402; (619) 767-2370 Determine status (Coastal Permit Required or Exempt): NO-X Habitat Management Plan Data Entry Completed? YES _ If property has Habitat Type identified in Table 11 of HMP, complete HMP Permit application and assess fees in Permits Plus (A/P/Ds, Activity Maintenance, enter CB#, toolbar, Screens, HMP Fees, Enter Acres of Habitat Type impacted/taken, UPDATE!) I I I I Inclusionary Housing Fee required: YES _ (Effective date of Inclusionary Housing Ordinance - May 21, 1993.) Data Entry Completed? YES NO (A/P/Ds, Activity Maintenance, enter CB#, toolbar, Screens, Housing Fees, Construct Housing Y/N, Enter Fee, UPDATE!) H:\ADMIN\COUNTER\BldgPlnchkRevChklst Rev 3/06 Site Plan: |~1 Provide a fully dimensional site plan drawn to scale. Show: North arrow, property lines, easements, existing and proposed structures, streets, existing street improvements, right-of- way width, dimensional setbacks and existing topographical lines (including all side and rear yard slopes). Provide legal description of property and assessor's parcel number. D Policy 44 - Neighborhood Architectural Design Guidelines D D 1 • Applicability: YES _ NO _ D D 2. Project complies YES _ NO _ ann Zoning: n n n n n n 1.Setbacks: Front: Interior Side: Street Side: Rear: Top of slope: Required Required Required Required Required 2. Accessory structure setbacks: Front: Interior Side: Street Side: Rear: Structure separation: 3. Lot Coverage: 4. Height: 5. Parking: Required Required Spaces Required Shown Shown Shown Shown Shown Required Required Required Required Required Shown Shown Shown Shown Shown Shown Shown Shown (breakdown by uses for commercial and industrial projects required) Residential Guest Spaces Required Shown r« /Additional Comments 'To OK TO ISSUE AND ENTERED APPROVAL INTO COMPUTER H:\ADMIN\COUNTER\BldgPlnchkRevChklst DATE Rev 3/06 BLDG. DEPT COPYCarlsbad Fire Department Plan Review Requirements Category: TI , COMM Date of Report: 04-08-2010 Reviewed by Name: DROGO DEVELOPMENT DBA IT'S A GRIND Address: STE 200 2744 CARLSBAD BLVD CARLSBAD CA 92008 Permit #:CB 1003 19 Job Name: IT'S A GRIND - COMBINE SUITES Job Address: 2744 CARLSBAD BL CBAD St: 100 cannot adequately conduct a n uij^n.UM'li'rr'i'iiiiiK ri'in|V1ltii>fN»i^,iJjjJhi .ijijilii .ihli codes and/or standards.~Please review carefully all cormjj^tts'attached. Please resubmit the necessaiy^IaTTS^ad/OT^specifications, with changes "clouded", to this office/fl$r review and approval. Conditions: Cond:CON0003911 [NOT MET] INSTRUCTIONS " This plan review has been conducted in order to verify conformance to minimum requirements of codes adopted by the Carlsbad Fire Department. " The items below require correction, clarification or additional information before this plan check can be approved for permit issuance. " Corrections or modifications to the plans must be clouded and provided with numbered deltas and revision dates along with a descriptive narrative of corrections addressing all comments. " Please direct any questions regarding this review to: Daryl Kit James (760) 724-7001 or kitfire@sbcglobal.net " Corrected plans and descriptive narrative to be submitted to: Daryl K. James & Associates, Inc. 205 Colina Terrace Vista, CA 92084 CORRECTIONS AO.l General Information Scope of Work " Provide the scope of work on this sheet Project Information Edition Separate Permit Sheet Index General Notes Denote number of stories Provide Sprinkler Classification of Occupancy in accordance with NFPA 13 Chapter 5 2002 Justify the deferral of all drawings other than sprinkler system. See Sheet E3 for comments Water heater detail is typically provided on Plumbing Sheets. Add sheet numbers to sheet electrical sheet descriptions. Stamp & sign electrical sheets. Notel 1. Provide fire extinguisher rating. Note 13. Add: NFPA 13 2002 Edition NFPA 72 2002 Edition Revise all references from UBC to CFC and ICBO to ICC. Page: 2 of 2 A2.1 Floor Plan " Title all notes either above the notes or under the notes, i.e. GENERAL NOTES appears above notes, FIREPLACE NOTES appears below notes. Door Notes Note 2. Revise to 34" minimum and 48" maximum Provide suite address specifications. Key Notes " Note 12. This note in not required where all doors are operable without the use of a key, special knowledge or effort. See Door Note 2. Typical Wall Construction " Note 5. Denote location(s) of penetrations. Provide and reference penetration details including fire proofing materials tested in accordance with ASTM E 814 or UL 1479. Floor Plan Provide egress analysis for all areas in accordance with CBC Section 1004. Compute the number of occupants at the rate of one occupant per unit of area as prescribed in CBC Table 1004.1.1. Determine the use based on a listed use that most resembles the proposed use. Provide seating layout. " Denote type and height of fire extinguisher in accordance with NFPA 10 requirements and denote location. Show on interior elevation sheet Wall Types " Provide listed design numbers for rated walls or reference CBC Table 720 item number. Coordinate with A6.3 Detail 7. Fireplace Notes " Note 1. Provide complete plans and manufacturer's cut sheets " Note 3. Revise reference UBC to CBC. Include roof penetration detail in accordance with the CBC and CMC " Provide drawings and details which specify compliance with CMC Chapter 9 including section references and/or ICC-ES Evaluation Report if available. A2.3 Ceiling Plan/Mechanical Duct Layout " Denote location of emergency lighting and reference Sheet E3. " Detail 4. Provide current Seismic T-Bar Ceiling System Report (ICC-ES) in accordance with CBC Sections 803.9.1.1 and 803.9.1.2 for fire-resistance-rated construction. " Provide Ceiling Legend as referenced the following note pertaining to interior materials located just above Detail 4. All Sheets " Provide notes only applicable to this project. A6.3 Architectural Details " Detail 7 references detail 13 on A.2.1. Detail 13 is not denoted on A2.1. " Provide water heater detail not provided. " Detail 16. Denote materials used, referencing the requirements of the CBC & CMC. E3 Lighting Fixture Floor Plan " Denote locations of emergency lighting. Determine method if lighting exit signs. Entry: 03/16/2010 By: DJ./CW Action: CO Cond: CON0003953 [NOT MET] CORRECTIONS A6.3 Architectural Details Fireplace detail 16 on Sheet A6.3 should denote actual clearances, etc. that is provided within the manufacturer's specs and/or CMC. The actual cut sheet showing the detail should be submitted with the plans. I could not locate UL# 307B in the PDF. If this cannot be verified, remove it from the Fireplace Notes. RECOMMENDED FOR APPROVAL Entry: 04/03/2010 By: JJK/cw Action: CO Cond: CON0003954 [MET] **APPROVED: THIS PROJECT HAS BEEN REVIEWED AND APPROVED FOR THE PURPOSES OF ISSUEANCE OF A BUILDING PERMIT. THIS APPROVAL IS SUBJECT TO FIELD INSPECTIONS, ANY REQUIRED TESTS, FIRE DEPARTMENT NOTATIONS, CONDITIONS IN CORRESPONDENCE AND COMPLIANCE WITH ALL APPLICABLE CODES AND REGULATIONS. THIS APPROVAL SHALL NOT BE HELD TO PERMIT OR APPROVE ANY VIOLATION OF THE LAW. Entry: 04/08/2010 By: JJK/cw Action: AP CORRECTION LIST #2 Page: 1 of 2 Daryl K. James & Associates, Inc. 205 Colina Terrace Vista, CA 92084 T. (760) 724-7001 Email: kitfire@sbcglobal.net Checked by: Daryl Kit James :e: April 3 2010 .DEPT COPY APPLICANT: Sam Drogo PROJECT NAME: It's A Grind Coffee House PROJECT DESCRIPTION: CB100319 1529 SF Tl JURISDICTION: Carlsbad Fire Department PROJECT ADDRESS: 2744 Carlsbad Blvd. Ste 100 INSTRUCTIONS • This plan review has been conducted in order to verify conformance to minimum requirements of codes adopted by the Carlsbad Fire Department. • The items below require correction, clarification or additional information before this plan check can be approved for permit issuance. • Corrections or modifications to the plans must be clouded and provided with numbered deltas and revision dates along with a descriptive narrative of corrections addressing all comments. • Please direct any questions regarding this review to: Daryl Kit James (760) 724-7001 or kitfire@sbcglobal.net • Corrected plans and descriptive narrative to be submitted to: Daryl K. James & Associates, Inc. 205 Colina Terrace Vista, CA 92084 CORRECTIONS A6.3 Architectural Details I Fireplace detail 16 on Sheet A6.3 should denote actual clearances, etc. that is provided within the manufacturer's specs and/or CMC. The actual cut sheet showing the detail should be submitted with the plans. I could not locate Ul# 307B in the PDF. If this cannot be verified, remove it from the Fireplace Notes. RECOMMENDED FOR APPROVAL BUILDING ENERGY ANALYSIS REPORT PROJECT: It's A Grind 2744 Carlsbad Blvd. Carlsbad, CA 92008 Project Designer: Ron Witteveen, AIA Architect 20032 E. Santiago Canyon Road Orange, CA 92869 (714)516-1511 Report Prepared by: Scott Davenport Linwood Engineering Associates 151 Kalmus Dr. Suite B-200 Costa Mesa, CA 92626 (805)441-8699 Job Number: 10001 Date: 3/21/2010 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2008 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC-www.energysoft.com. EnergyPro 5.0 by Energy Soft User Number: 5863 RunCode: 2010-03-21 T16:16:3 10:10001 TABLE OF CONTENTS Cover Page 1 Table of Contents 2 Nonresidential Performance Title 24 Forms 3 Form LTG-MM Lighting Mandatory Measures 11 Form MECH-MM Mechanical Mandatory Measures 12 EnergyPro 5.0 by EnergySoft job Number: ID: 10001 User Number 5863 PERFORMANCE CERTIFICATE OF COMPLIANCE (Part 1 of 3)PERF-1C Project Name It's A Grind Date 3/21/2010 Project Address 2744 Carlsbad Blvd.Carlsbad Climate Zone CA Climate Zone 07 Total Cond. Floor Area 1,500 Addition Floor Area 1,500 GENERAL INFORMATION Building Type:E Nonresidential D D Relocatable - indicate D High-Rise Residential D specific climate zone D Hotel/Motel Guest Room all climates Phase of Construction: D New Construction D Addition 0 Alteration STATEMENT OF COMPLIANCE This certificate of compliance lists the building features and specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations. This certificate applies only to a Building using the performance compliance approach. The documentation author hereby certifies that the documentation is accurate and complete. Documentation Author Name Scott Davenport Signature ComPany Linwood Engineering Associates Date 3/21/2010 Address 151 Kalmus Dr. Suite 6-200 Phone (805) 441-8699 City/State/Zip Cosfg Mesg_ CA g2626 The Principal Designer hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application. The proposed building has been designed to meet the energy efficiency requirements contained in sections 110, 116 through 118, and 140 through 149 of Title 24, Part 6. Please check one: ENV. LTG. MECH. D D D I hereby affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code to sign this document as the person responsible for its preparation; and that I am licensed in the State of California as a civil engineer, mechanical engineer, electrical engineer, or I am a licensed architect. I affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code by section 5537.2 or 6737.3 to sign this document as the person responsible for its preparation; and that I am a licensed contractor performing this work. I affirm that I am eligible under Division 3 of the Business and Professions Code to sign this document because it pertains to a structure or type of work described as exempt pursuant to Business and Professions Code Sections 5537, 5538 and 6737.1. Principal Envelope Designer Name Signature Company Envelope Compliance Not In The Scope Of This Document Date Address License # City/State/Zip Phone Principal Mechanical Designer Name Signature Company Mechanical Compliance Not In the Scope Of This Submittal Date Address License # City/State/Zip Principal Lighting Designer Name Scoff Davenport Signature Company Address 151 Kalmus Dr. Suite B-200 City/State/Zip Cosfg Mesa_ CA g2626 Phone (805; 441-8699 INSTRUCTIONS TO APPLICANT COMPLIANCE & WORKSHEETS (check box if worksheets are included) D ENV-1C Certificate of Compliance. Required on plans. Q MECH-1C 0 LTG-1C Certificate of Compliance. Required on plans. Q MECH-2C 0 LTG-2C Lighting Controls Credit Worksheet. D MECH-3C D LTG-3C Indoor Lighting Power Allowance. D MECH-5C Certificate of Compliance. Required on plans. Air/Water Side/Service Hot Water & Pool Requirements. Mechanical Ventilation and Reheat. Mechanical Equipment Details. EnergyPro 5.0 by EnergySoft User Number: 5863 RunCode: 2010-03-21T16:16:36 ID: 10001 Page 3 of 12 PERFORMANCE CERTIFICATE OF COMPLIANCE (Part 2 of 3) PERF-1 C Project Name It's A Grind Date 3/21/2010 ANNUAL TDV ENERGY USE SUMMARY (kBtu/sqft-yr) Standard Proposed Compliance Energy Component Design Design Margin Space Heating Space Cooling Indoor Fans Heat Rejection Pumps & Misc. Domestic Hot Water Lighting \ Receptacle Process Process Lighting TOTALS Percent better than Standard 0.40 0.40 96.07 795.79 58.02 58.02 0.00 0.00 0.00 0.00 28.32 28.32 20.76 779.32 58.32 58.32 0.00 0.00 0.00 0.00 (61.28 460.17 0.00 0.28 0.00 0.00 0.00 0.00 0.84 0.00 0.00 7.72 0.2 % ( 0.2% excluding process) BUILDING COMPLIES GENERAL INFORMATION Building Orientation (N) o Number of Stories 7 Number of Systems 2 Number of Zones 2 deg Conditioned Floor Area 1500 sqft. Unconditioned Floor Area o sqft. Conditioned Footprint Area o Sqft. Natural Gas Available On Site Yes Orientation Gross Area Front Elevation Left Elevation Rear Elevation Right Elevation Total Roof (N) 0 (E) 0 (S) 486 (W) 270 756 0 Standard Lighting Power Density Prescriptive Envelope TDV Energy 1.397 W/sqft. 76,254 Glazing Area Glazing Ratio sqft. sqft. sqft. sqft. sqft. sqft. o sqft. 0.0% o sqft. 0.0% 345 Sqft. 77.0% 738 sqft. 57.7% 483 Sqft. 63.9% o sqft. 0.0% Proposed 1397 W/sqft. 23,546 Remarks: EnemvPro 5.0 by EneravSoft User Number: 5863 RunCode: 2010-03-21T16:16:3 10:10001 Paae4of12 PERFORMANCE CERTIFICATE OF COMPLIANCE (Part 3 of 3)PERF-1C Project Name Ifs A Grind Date 3/21/2010 ZONE INFORMATION System Name Zone Name Occupancy Type Floor Area Inst. LPD (W/sf)1 Ctrl. Credits (W/sf)2 Allowed LPD Area (W/sf)3 Tailored (W/sf)4 Proc. Loads (W/sf) (E)AC Coffee Store Retail Sales, Wholesale 1,195 1.608 0.040 Support Areas Corridor/Restroom/Support 305 0.905 0.181 Notes:!. See LTG-1C (items marked with asterisk, see LTG-1-C by others) 2. See LTG-2C 3. See LTG-3C (by others) 4. See LTG-4C Items above require special documentation EXCEPTIONAL CONDITIONS COMPLIANCE CHECKLIST The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justifications, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. The DHW System A 0 Smith Water Products BTF-80 is a non-NAECA large storage gas water heater. Verify DHW details. The exceptional features listed in this performance approach application have specifically been reviewed. Adequate written justification and documentation for their use have been provided by the applicant. Authorized Signature or Stamp Energy Pro 5.0 by Energy Son User Number: 5863 RunCode: 2010-03-21716:16:36 ID: 10001 Page 5 of 12 CERTIFICATE OF COMPLIANCE (Part 1 of 3) LTG-1 C Project Name Date It's A Grind 3/21/2010 INDOOR LIGHTING SCHEDULE and FIELD INSPECTION ENERGY CHECKLIST Installation Certificate, LTG-1 - INST (Retain a copy and verify form is completed and signed.) Certificate of Acceptance, LTG-2A (Retain a copy and verify form is completed and signed.) Field Inspector D Field Inspector D A separate Lighting Schedule Must Be Filled Out for Conditioned and Unconditioned Spaces Installed Lighting Power listed on this Lighting Schedule is only for: m CONDITIONED SPACE D UNCONDITIONED SPACE m The actual indoor lighting power listed below includes all installed permanent and portable lighting systems in accordance ^ with§146(a). Only for offices: Up to the first 0.2 watts per square foot of portable lighting shall not be required to be included in the 0 calculation of actual indoor lighting power density in accordance with the Exception to §146(a). All portable lighting in excess of 0.2 watts per square foot is totaled below. A None or Item Tag Luminaire (Type, Lamps, Ballasts) B Complete Luminaire Description' (i.e, 3 lamp fluorescent troffer, F32T8, one dimmable electronic ballasts) (1) 26w Compact Fluorescent Triple 4 Pin Elec 25w Low Voltage Halogen 20w Low Voltage Halogen 35w Low Voltage Halogen (2) 4 ft Fluorescent T8 Energy Savings Elec (2) 2ft Fluorescent T8 Rapid Start Installed Watts C Special FeaturesD D n n n n n n n n n n n n n n n n n n D Watts perLuminaire26 25 20 35 54 34 E How wattage Was determined CEC Default From NA8 m m 0 m m 0 n n n n n n n n n n n n n n 0) o •D £o =6 $2o «*>o0 O< H n n n n n n n n n n n n n n n n n n n n F Number ofLuminaires28 3 24 19 4 1 Installed Watts Page Total: Building total number of pages: Installed Watts Building Total (Sum of all pages) Enter into LTG-1 C Page 4 of 4 G GT X -o 0<D —=3^ H 728 75 480 665 216 34 2,198 H Field Inspector2 in %Q. D D D n n n n D n n n n D D D n n n n n £ n n n n n n n n n n D n n n n n n n n n 2,198 1. Wattage shall be determined according to Section 130 (d and e). Wattage shall be rating of light fixture, not rating of bulb. 2 . If Fail then describe on Page 2 of the Inspection Checklist Form and take appropriate action to correct. Verify building plans if necessary. EnergyPro 5.0 by EnergySoft User Number: 5863 RunCode: 2010-03-21 T16:16:3\ ID: 10001 Page 6 of 12 CERTIFICATE OF COMPLIANCE (Part 2 of 3)LTG-1C Project Name Ifs A Grind Date 3/21/2010 INDOOR LIGHTING SCHEDULE and FIELD INSPECTION ENERGY CHECKLIST Fill in controls for all spaces: a) area controls, b) multi-level controls, c) manual daylighting controls for daylit areas > 250 ft2, automatic daylighting controls for daylit areas > 2,500 ft2, d) shut-off controls, e) display lighting controls, f) tailored lighting controls - general lighting controlled separately from display, ornamental and display case lighting and g) demand responsive automatic controls for retail stores > 50,000 ft2, in accordance with Section 131. MANDATORY LIGHTING CONTROLS- FIELD INSPECTION ENERGY CHECKLIST Field Inspector Type/ Description Number of Units Location in Building Special Features Pass Fail n n n "* °\JL n n n n n n n n n n n n n n n n n n n SPECIAL FEATURES INSPECTION CHECKLIST (See Page 2 of 4 of LTG-1C) The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the special justification and documentation submitted. Field Inspector's Notes or Discrepancies: Energy Pro 5.0 by EnergySoft User Number: 5863 RunCode: 2010-03-21T16:16:3 ID: 10001 Page 7 of 12 CERTIFICATE OF COMPLIANCE Project Name ft 's A Grind (Part 3 of 3) LTG-1C Date 3/21/2010 CONDITIONED AND UNCONDITIONED SPACE LIGHTING MUST NOT BE COMBINED FOR COMPLIANCE Indoor Lighting Power for Conditioned Spaces Indoor Lighting Power for Unconditioned Spaces Installed Lighting (from Conditioned LTG-1C, Page 2) Lighting Control Credit Conditioned Spaces (from LTG-2C) Adjusted Installed Lighting Power Complies if Installed £ Allowed Allowed Lighting Power Conditioned Spaces (from LTQ-3C or PERF-1) Watts Watts Installed Lighting Q ' (from Unconditioned LTG-1C, Page 2) 103 Lighting Control Credit . Q Unconditioned Spaces (from LTG-2C) „ OQ(. Adjusted Installed ,, *'uyo Lighting Power t Complies if Installed ^ Allowed £ Allowed Lighting Power 2'095 Unconditioned Spaces (from LTG-3C) Required Acceptance Tests Designer: This form is to be used by the designer and attached to the plans. Listed below is the acceptance test for the Lighting system, LTG-2A. The designer is required to check the acceptance tests and list all control devices serving the building or space shall be certified as meeting the Acceptance Requirements for Code Compliance. If all the lighting system or control of a certain type requires a test, list the different lighting and the number of systems. The NA7 Section in the Appendix of the Nonresidential Reference Appendices Manual describes the test. Since this form will be part of the plans, completion of this section will allow the responsible party to budget for the scope of work appropriately. Forms can be grouped by type of Luminaire controlled. Enforcement Agency: Systems Acceptance. Before Occupancy Permit is granted for a newly constructed building or space or when ever new lighting system with controls is installed in the building or space shall be certified as meeting the Acceptance Requirements. The LTG-2A form is not considered a complete form and is not to be accepted by the enforcement agency unless the boxes are checked and/or filled and signed. In addition, a Certificate of Acceptance forms shall be submitted to the enforcement agency that certifies plans, specifications, installation certificates, and operating and maintenance information meet the requirements of §1 0-103(b) of Title 24 Part 6. The field inspector must receive the properly filled out and signed forms before the building can receive final occupancy. A copy of the LTG-2A for each different lighting luminaire control(s) must be provided to the owner of the building for their records. Luminaires Controlled Equipment Requiring Testing Window Daylighting Dimming - Manual Dimming - Manual Occ Sensor- <= 250 sqft Occ Sensor- <= 250 sqft Occ Sensor- <= 250 sqft Occ Sensor- <= 250 sqft Description (1) 26w Compact Fluorescent Triple 4 20w Low Voltage Halogen 20w Low Voltage Halogen (1) 26w Compact Fluorescent Triple 4 (2) 4 ft Fluorescent T8 Energy Saving: (2) 2ft Fluorescent T8 Rapid Start (2) 4 ft Fluorescent T8 Energy Saving: EnergyPro 5. 0 by EnergySofi User Number: 5863 Number of Luminaire controls 19 10 14 1 3 1 1 Location Sales/Seating 101 Sales/Seating 101 Drink Service 102 Restroom 105 Drink Prep 103 Drink Prep 103 Storage 104 LTG-2A Controls and Sensors and Automatic Daylighting Controls Acceptance 0 0 ia 0 El m m n n n n n n n n n RunCode: 2010-03-21T16:16:3 ID: 10001 Page 8 of 12 LIGHTING CONTROLS CREDIT WORKSHEET (Part 1 of 2) LTG-2C Project Name Date It's A Grind 3/21/2010 POWER ADJUSTMENT FACTORS (PAF) FOR NON-DAYLIGHT CONTROLS A Separate PAF Worksheet Must Be Filled Out for Conditioned and Unconditioned Spaces. Control Credits listed on this schedule are only for: S CONDITIONED SPACES D UNCONDITIONED SPACES A Room # Zone ID Areas Sa/es/Seaf/ng 101 Drink Service 102 Restroom 105 Drink Prep 103 Drink Prep 103 Storage 104 B Lighting Control Description1 Dimming - Manual Dimming - Manual Occ Sensor- <= 250 sqft Occ Sensor- <= 250 sqft Occ Sensor- <= 250 sqft Occ Sensor - <= 250 sqft C Plan Reference D Room Area (ft2) 840 355 45 150 150 110 E Watts of Control Lighting 200 280 26 162 34 54 F Power Adjustments Factor2 0.10 0.10 0.20 0.20 0.20 0.20 PAGE TOTAL Note: Conditioned and Unconditioned Space shall be separately totaled Building total of non-daylight control credit watts for all pages of LTG-2C Page 1 of 2 Enter building total of all daylight controls credit watts from LTG-2C Page 2 of 2 BUILDING TOTAL OF ALL CONTROL CREDIT WATTS (FOR BOTH NON-DAYLIGHT AND DAYLIGHT CONTROL CREDITS) Enter in LTG-1C; Page 4: Lighting Control Credit as appropriate for CONDITIONED or UNCONDITIONED Spaces G Control Credit Watts (ExF) 20 28 5 32 7 11 103 103 1 . Description shall be consistent with Type of Control defined in Table 146-C 2. Power Adjustment Factor taken from Table 146-C EnergyPro 5.0 by EnergySoft User Number: 5863 RunCode: 2010-03-21T16:16:3( ID: 10001 Page9of12 | LIGHTING CONTROLS CREDIT WORKSHEET (Part 2 of 2) LTG-2C 1Date3/21/2010IProject NameIt's A Grind| POWER ADJUSTMENT FACTORS (PAF) FOR DAYLIGHT CONTROLSAF Worksheet Must Be Filled Out for Conditioned and Unconditioned Spaces. Daylight Control Credits listed on this schedule are only for:ONED SPACES D UNCONDITIONED SPACES |IA Separate PEZl CONDITI^ -3 - I O LL UJ O 0 OQ < o ~ en —i= T3 4=i ~3cz CD nj x<gos^ COih5* -1— 1 f 1 £tl5 H- "OO 05 d) W gi j££5° = c\T~~ a i^! "'£%£]33*!0Q 5"s'" t^S LD£ Tj- 1 .01 J£c/> oLi-Type DaylightControlled 1El only one= CO>, 03J£ •;CO < = .S-o |!|> Q CC >o = C0) O 5§ UJ •P- £<M .51 CO•>, ®£< moss Q. ^Q> DC }||3P!S /jBpuooos }]|8P!S AjBLUUd lll^S *9 CO Igs £r3< o oo 0 O)S «5 0> O OOO O Oso o n Q n 1 Sales/Seating 1Cn n n n a n n n n n D n n D n n n n n D n n n n n n n n n n D n n n n n n n n PAGE TOTALCM "o CM CD DlCC Q. 0 CM 6 "o CO CD OJ CO Q. "o CD_Q E3-z.Building total for daylight control credit watts for all pages of LTG-2C; Page 2 of 2Enter in bottom of LTG-2C; Page 1 of 2 for building total of all daylight controls credit from LTG-2C; Page 2 of 2Conditioned and UnconditionedSpaces shall be separately totaledt daylight areas are controlled together, the PAF is determined based on the secondary sidelit effective aperture for both the primary and secondary sidelit daylightnee to Section 131(c)windows or skylights determined in accordance with Section 146(a)2Ei Skylit Area determined in accordance with Section 1 46(a)2E(iii)rdance with Section 146(a)2Ein accordance with Table 146-Celit and secondary sideliis determined in accordaighting transmittance of:y, Well Cavity Ratio, antrture determined in acccment Factor determined" Issl-s^ ~pls i :!•> ^ '-a | ^sTKl^I 2= CO Q > 5 LU O. ff . .1- ca CM co •* in CD CNT~ "5o V- 8.£ ^~ooo Q *tot- U3p *-CMs§ •JS51 C")gVO cS-Q 1 !1 *o IO1 1LU LINE VOLTAGE TRACK LIGHTING WORKSHEET (Page 1 of 2) LTG-5C Project Name:It's A Grind Date: 03/21/10 SD METHOD 1 -VOLT-AMPERE (VA) RATING OF THE BRANCH CIRCUIT(S) D This is the only option available for determining wattage of line-voltage busway and track rated for more than 20 amperes D One of four options available for determining wattage of line-voltage busway and track rated for 20 amperes or less A BRANCH CIRCUIT NAME OR ID TOTAL: Enter total on the bottom of LTG-5C Page 2 of 2 B VOLT-AMPERE (VA) RATING OF THE BRANCH CIRCUIT ^ D METHOD 2 - USE THE HIGHER OF: 45 WATTS / LINEAR FOOT OF TRACK- OR TOTAL RATED WATTAGE OF ALL LUMINAIRES D One of four options available for determining wattage of line-voltage busway and track rated for 20 amperes or less A TRACK* OR NAME B LINEAR FEET OF TRACK C (W/LF) 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 D BxC (W) E TOTAL RATED WATTAGE OF ALL LUMINAIRES TOTAL Enter total on the bottom of LTG-5C Page 2 of 2 F LARGER OF (D or E) 2008 Nonresidential Compliance Form August 2009 LINE VOLTAGE TRACK LIGHTING WORKSHEET (Page 2 of 2) LTG-5C Project Name:It's A Grind Date: 03/21/10 S m METHOD 3 - USE THE HIGHER OF: 12.5 WATTS / LINEAR FOOT OF TRACK - OR VA RATING OF INTEGRAL CURRENT LIMITER D One of four options available for determining wattage of line-voltage busway and track rated for 20 amperes or less. D Only integral current Hmiters which are certified to the Energy Commission use this method. A Track or Name # #1 thru #12; typical for all 12. B Linear Feet of Track 1.5' C (W/LF) 12.5 12.5 12.5 12.5 12.5 12.5 D BxC (W) 18.75W E VA Rating of Integral Current Limiter 40.0W \ \ / 40.0WX12 TOTAL: Enter total on the bottom of this page F Larger of (Dor E) 480W r 480W D METHOD 4 - DEDICATED TRACK LIGHTING OVERCURRENT PROTECTION PANEL D One of four options available for determining wattage of line-voltage busway and track rated for 20 amperes or less D Overcurrent protection panel is listed as defined in §101 in accordance with §130(d)3B(iv)a. D Overcurrent protection panel is used only with track lighting in accordance with §l30(d)3B(iv)b. D Overcurrent protection panel is permanently installed in an electrical equipment room or permanently installed adjacent to the lighting panel board providing supplementary Overcurrent protection for the track lighting circuits served by the supplementary Overcurrent protection panel in accordance -with §l3Q(d)3B(iv)c. D Overcurrent protection panel is prominently labeled in accordance with §130(d)3B(iv)d. OVERCURRENT PROTECTION PANEL A NAME OR ID B Voltage of the Branch Circuit C Complete list of Amperage Rating for Each Device Installed in the Panel D Sum of the Ampere Rating of all Devices TOTAL: Enter total on the bottom of this page E Sum of the Ampere Ratings of all of the Devices Times The Branch Circuit Voltage (BxD) D TOTALS OF ALL METHODS USED TO DETERMINE THE WATTAGE OF LINE-VOLTAGE TRACK AND PLUG-IN BUSWAY ENTER TOTAL FROM METHOD 1 ENTER TOTAL FROM METHOD 2 ENTER TOTAL FROM METHOD 3 ENTER TOTAL FROM METHOD 4 TOTAL TRACK / BUSWAY WATTAGE: 480W 480W 2008 Nonresidential Compliance Form August 2009 LIGHTING MANDATORY MEASURES: NONRESIDENTIAL LTG-MM Project Name Ifs A Grind Date 3/21/2010 Indoor Lighting Measures: §131 (d): Shut-off Controls For every floor, all interior lighting systems shall be equipped with a separate automatic control to shut off the lighting. 1. This automatic control shall meet the requirements of Section 119 and may be an occupancy sensor, automatic time switch, or other device capable of automatically shutting off the lighting. 2.Override for Building Lighting Shut-off: The automatic building shut-off system is provided with a manual, accessible override switch in sight of the lights. The area of override is not to exceed 5,000 square feet. §119(h):Automatic Control Devices Certified: All automatic control devices specified are certified, all alternate equipment shall be certified and installed as directed by the manufacturer. §111:Fluorescent Ballast and Luminaires Certified: All fluorescent fixtures specified for the project are certified and listed in the Directory. All installed fixtures shall be certified. Tandem Wiring for One and Three Lamp Fluorescent Fixtures: All one and three lamp fluorescent fixtures are tandem §132: wired with two lamp ballasts where required by Standards Section 132; or all one and three lamp fluorescent fixtures are specified with electronic high-frequency ballasts and are exempt from tandem wiring requirements. §131 (a): individual Room/Area Controls: Each room and area in this building is equipped with a separate switch or occupancy sensor device for each area with floor-to-ceiling walls. Uniform Reduction for Individual Rooms: All rooms and areas greater than 100 square feet and more than 0.8 watts §131 (b): per square foot of lighting load shall be controlled with bi-level switching for uniform reduction of lighting within the room. §131(c): Daylight Area Control: All rooms with windows and skylights that are greater than 250 square feet and that allow for the effective use of daylight in the area shall have 50% of the lamps in each daylit area controlled by a separate switch; or the effective use of daylight cannot be accomplished because the windows are continuously shaded by a building on the adjacent lot. Diagram of shading during different times of the year is included on plans. §131 (c): Display Lighting. Display lighting shall be separately switched on circuits that are 20 amps or less.6. Outdoor Lighting Measures: §130(c)1: Mandatory lighting power determination for medium base sockets without permanently installed ballasts §132{a):All permanently installed luminaires with lamps rated over 100 Watts either have a lamp efficacy of at least 60 lumens per Watt or are controlled by a motion sensor. §132(b):All Luminaires with lamps rated greater than 175 Watts in hardscape area, including parking lots, building entrances, canopies, and all outdoor sales areas meet the Cutoff Requirements. §132(c)1: All permanently installed outdoor lighting meets the control requirements listed. §132(c):Building facades, parking lots, garages, canopies, and outdoor sales areas meet the Multi-Level Lighting Requirements listed. znergyPro 5.0 by EnergySoft User Number: 5863 Run Code; 2010-03-21716:16:36 ID: 10001 Page 11 of 12 MECHANICAL MANDATORY MEASURES: NONRESIDENTIAL MECH-MM Project Name It's A Grind Date 3/21/2010 Equipment and System Efficiencies §111:Any appliance for which there is a California standard established in the Appliance Efficiency Regulations will comply with the applicable standard. §115(a): Fan type central furnaces shall not have a pilot light. §123:Piping, except that conveying fluids at temperatures between 60 and 105 degrees Fahrenheit, or within HVAC equipment, shall be insulated in accordance with Standards Section 123. §124:Air handling duct systems shall be installed and insulated in compliance with Sections 601, 602, 603, 604, and 605 of the CMC Standards. Controls §122(e): Each space conditioning system shall be installed with one of the following: 1 A. Each space conditioning system serving building types such as offices and manufacturing facilities (and all others not explicitly exempt from the requirements of Section 112 (d)) shall be installed with an automatic time switch with an accessible manual override that allows operation of the system during off-hours for up to 4 hours. The time switch shall be capable of programming different schedules for weekdays and weekends and have program backup capabilities that prevent the loss of the device's program and time setting for at least 10 hours if power is interrupted; or 1B. An occupancy sensor to control the operating period of the system; or 1C. A 4-hour timer that can be manually operated to control the operating period of the system. 2.Each space conditioning system shall be installed with controls that temporarily restart and temporarily operate the system as required to maintain a setback heating and/or a setup cooling thermostat setpoint. §122(g): Each space conditioning system serving multiple zones with a combined conditioned floor area more than 25,000 square feet shall be provided with isolation zones. Each zone: shall not exceed 25,000 square feet; shall be provided with isolation devices, such as valves or dampers that allow the supply of heating or cooling to be setback or shut off independently of other isolation areas; and shall be controlled by a time control device as described above. §122(c):Thermostats shall have numeric setpoints in degrees Fahrenheit (F) and adjustable setpoint stops accessible only to authorized personnel. §122(b):Heat pumps shall be installed with controls to prevent electric resistance supplementary heater operation when the heating load can be met by the heat pump alone Each space conditioning system shall be controlled by an individual thermostat that responds to temperature within the zone. Where used to control heating, the control shall be adjustable down to 55 degrees F or lower. For cooling, the §122(a&b): control shall be adjustable up to 85 degrees F or higher. Where used for both heating and cooling, the control shall be capable of providing a deadband of at least 5 degrees F within which the supply of heating and cooling is shut off or reduced to a minimum. Ventilation §121 (e):Controls shall be provided to allow outside air dampers or devices to be operated at the ventilation rates as specified on these plans. §122(f):All gravity ventilating systems shall be provided with automatic or readily accessible manually operated dampers in all openings to the outside, except for combustion air openings. Ventilation System Acceptance. Before an occupancy permit is granted for a newly constructed building or space, or a §121 (f): new ventilating system serving a building or space is operated for normal use, all ventilation systems serving the building or space shall be certified as meeting the Acceptance Requirements for Code Compliance Service Water Heating Systems §113(c)Installation 3. Temperature controls for public lavatories. The controls shall limit the outlet Temperature to 110° F. _ Circulating service water-heating systems shall have a control capable of automatically turning off the circulating pump when hot water is not required. Energy Pro 5.0 by Energy Son User Number: 5863 RunCode: 2010-03-21716:16:36 ID: 10001 Page 12 of 12 CO > 0 TOo Q. a~n—i;o~oj§i|i ^ 33 00 ~ CO-gJdcoS.2:OH73>IB!zUJzwmwgooo-o 'II^^SSo§g£?Q•jSSgwHogom«£*< vHQ5mo55^ol!>^0o^zz^Sz5 _' > Xi ^ O ^o^lfs !5 rn m ^ r-em^^^P !5 rn m r|.^rri-(>;=> 5o o C<r '^ooU!^-. <-• slllig-rn^OgyX c/) ;fc O ^Ris??^ S35SS3mioS 2 m z o I,-,?-o§°ir^Ss-S>5>^5I1«sllsgrfir-^z S?°§§ 8 ID > -n Vi "DCm-D3j! -TiKsgis aW0_(33 3 l°ow -H C~ ^H O i CONSTRUCTION BEGUN AFTEF THE PUNS WERE APPROVEC\NS WILL BE VOIDED AND NEWED FOR APPROVAL.TJ - -*3i^§(/3 S m 5^cnmm 73 |o ?Y, MID AND FINAL INSPIII! Ho 2 2 •Pjj CDi V)2 01 a -< T3 ^O H 0 m _2 O OUNTY OF SAN DIEGDEPARTMENT OFIVIRONMENTAL HEALPLAN CHECKH OI CARLSBAD BLVD. -Ct a a a n ri a D E a WALK n I IT SAN DIEGO REGIONAL HAZARDOUS MATERIALS QUESTIONNAIRE OFFICE USE ONLY UPFP# HV# BP DATE / Business Name *> A Business Contact Telephone # Project Address City State Zip Code APN# Mailing Address City State Zip Code Plan File# Project Contact Telephone #r The following questions represent the facility's activities, NOT the specific project description. PART I: FIRE DEPARTMENT- HAZARDOUS MATERIALS DIVISION: OCCUPANCY CLASSIFICATION: Indicate by circling the item, whether your business will use, process, or store any of the following hazardous materials. If any of the items are circled, applicant must contact the Fire Protection Agency with jurisdiction prior to plan submittal. 5. Organic Peroxides 9. 6. Oxidizers 10. 7. Pyrophorics 11. 8. Unstable Reactives 12. 1. Explosive or Blasting Agents 2. Compressed Gases 3. Flammable/Combustible Liquids 4. Flammable Solids Water Reactives Cryogenics Highly Toxic or Toxic Materials Radioactives 13. Corrosives 14. Other Health Hazards None of These. PART II: SAN DIEGO COUNTY DEPARTMENT OF ENVIRONMENTAL HEALTH - HAZARDOUS MATERIALS DIVISIONS (HMD): If the answer to any of the questions is yes, applicant must contact the County of San Diego Hazardous Materials Division, 1255 Imperial Avenue, 3'" floor, San Diego, CA 92101. Call (619) 338-2222 prior to the issuance of a building permit. FEES ARE YES 1. D 2. D 3. D 4. D 5. D 6. D REQUIRED. Expected Date of Occupancy: "5 / / / /O NO B> [3 0 B E P- Is your business listed on the reverse side of this form? (check all that apply). Will your business dispose of Hazardous Substances or Medical Waste in any amount? Will your business store or handle Hazardous Substances in quantities equal to or greater than 55 gallons, 500 pounds, 200 cubic feet, or carcinogens/reproductive toxins in any quantity? Will your business use an existing or install an underground storage tank? Will your business store or handle Regulated Substances (CalARP)? Will your business use or install a Hazardous Waste Tank System (Title 22, Article 10)? D CalARP Exempt / Date Initials D CalARP Required / Date Initials CH CalARP Complete / Date Initials PART III: SAN DIEGO COUNTY AIR POLLUTION CONTROL DISTRICT: If the answer to any of the questions below is yes, applicant must contact the Air Pollution Control District (APCD), 10124 Old Grove Road, San Diego, CA 92131-1649, telephone (858) 586-2600 prior to the issuance of a building or demolition permit. Note: if the answer to questions 3 or 4 is yes, applicant must also submit an asbestos notification form to the APCD at least 10 working days prior to commencing demolition or renovation, except demolition or renovation of residential structures of four units or less. Contact the APCD for more information. 1. YES D NO Will the subject facility or construction activities include operations or equipment that emit or are capable of emitting an air contaminant? (See the ' APCD factsheet at http://www.sdapcd.org/info/facts/perrnits.pdf, and the list of typical equipment requiring an APCD permit on the reverse side of this from. Contact APCD if you have any questions). 2. D D (ANSWER ONLY IF QUESTION 1 IS YES) Will the subject facility be located within 1,000 feet of the outer boundary of a school (K through 12)? (Public and private schools may be found after search of the California School Directory at http://www.cde.ca.gov/re/sd/: or contact the appropriate school district). fj S Will there be renovation that involves handling of any friable asbestos materials, or disturbing any material that contains non-friable asbestos? C] Pj-' Will there be demolition involving the removal of a load supporting structural member? 3. 4. Briefly describe business activities:Briefly describe proposed project: -TO: -n=> A I declare under pgnaJlv_ofperjury that to the best of my knowledge and belief the responses made herein are true and correct. Nawfi'ol'btvner'or' Authonzed'AgerT Signature of Owner or Authorized Agent Date FOR OFFICIAL USE ONLY:FIRE DEPARTMENT OCCUPANCY CLASSIFICATION:, BY:DATE: EXEMPT OR NO FURTHER INFORMATION REQUIRED COUNTY-HMD APCD RELEASED FOR BUILDING PERMIT BUT NOT FOR OCCUPANCY COUNTY-HMD APCD RELEASED FOR OCCUPANCY COUNTY-HMD APCD HM-9171 (04/07)County of San Diego - DEH - Hazardous Materials Division iFireplaces I 1833 Diamond St. San Marcos, CA 92078 760/ 752-7789 FAX 760/752-7781 July 14, 2010 Drogo Development Inc. Dba It's A 6rind 2744 Carlsbad Blvd. #200 Carlsbad, Ca. 92008 Re: Fireplace Install Model #Inf inity by Heat n Glo Location: 2744 Carlsbad Blvd, Suite #100 To Whom It May Concern: On July 8, 2010, our NFI certified technicians, Chris Parisi NFI ID # 138921, and Scott Clemence NFI ID # 112644, completed the fireplace install in accordance with the guidelines established in the installation manual as written by Heat n Glo. Written documentation and pictures of the installation have been reviewed by Janie S. Patterson, (Responsible Managing Officer) RMO for our corporation - Fireplaces Plus Inc, which holds contractor's specialty license # 811295. Should you have any further questions regarding this matter, please do not hesitate to contact our office. We thank-you for yo r business, Sales Coordinator Check a License or Home Improvement Salesperson (HIS) Registration - Contractors Stat. Department of Consumer Affairs **** - Contractors State License feoard Contractor's License Detail - License # 811043 ^» DISCLAIMER: A license status check provides information taken from the CSLB license database. Before relying on this information, you should be aware of the following limitations. ••» CSLB complaint disclosure is restricted by law (B&P 7124,6). If this entity is subject to public complaint disclosure, a link for complaint disclosure will appear below. Click on the link or button to obtain complaint and/or legal action information. ;* Per B&P 7071.17, only construction related civil judgments reported to the CSLB are disclosed. ••» Arbitrations are not listed unless the contractor fails to comply with the terms of the arbitration. ••>>> Due to workload, there may be relevant information that has not yet been entered onto the Board's license database. License Number: Business Information: Entity: Issue Date: Expire Date: License Status: Classifications: 811043 Extract Date: 02/23/2010 DROGO DEVELOPMENT INC 2744 CARLSBAD BLVD #200 CARLSBAD, CA 92008 Business Phone Number: (760) 720-0597 Corporation 07/26/2002 07/31/2010 This license is current and active. All information below should be reviewed. CLASS DESCRIPTION GENERAL BUILDING CQNIRACTQB Bonding: CONTRACTOR'S BOND This license filed Contractor's Bond number SC6053500 in the amount of $12,500 with the bonding company AMERICAN.CONTRACTORS-.INDEMNITY COMPANY. Effective Date: 03/02/2009 Contractor's Bonding History BOND OF QUALIFYING INDIVIDUAL 1. The Responsible Managing Officer (RMO) SAMUEL DROGO certified that he/she owns 10 percent or more of the voting stock/equity of the corporation. A bond of qualifying individual is not required. Effective Date: 07/26/2002 This license has workers compensation insurance with the SIAIE CQMPEMSAIION INSURANCE.FUND Workers1 Compensation: Policy Number: 509-0002321 Effective Date: 01/01/2010 Expire Date: 01/01/2011 WojJsejsLCgjTipensaJig.ri.History Personnel listed on this license (current or disassociated) are listed on other licenses. Personnel List I Other Licenses Conditions of Use | Privacy Policy Copyright © 2010 State of California https://www2.cslb.ca.gov/OnlineServices/CheckLicense/LicenseDetail.asp 02/23/2010 •^ IF ^> z1 >s t S S I! ft 'I 0 \ V ?i IV3 -^ D< —^, ^}?f Al J OJU ^D \^ Cv c <=^ 9 ">118 •ft fl