Loading...
HomeMy WebLinkAbout2744 CARLSBAD BLVD; BLDG 10; PC040100; PermitCity of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 10-17-2006 Plan Check Permit No: PC040100 Building Inspection Request Line (760) 602-2725 Job Address: 2744 CARLSBAD BL CBAD Permit Type: PLANCK Status: PENDING Parcel No: 2031722700 Lot#: 0 Applied: 08/24/2004 Valuation; $0.00 Construction Type: Entered By; RMA Reference #: Plan Approved: Issued: Project Title; VILLAGE BY SEA-TYPICAL TENNANT Inspect Area: IMPROVEMENT FOR IDENTICAL! 0 RETAIL SUITES Applicant: Owner: AARON GALAUDET STE 100 539 CARLSBAD VILLAGE DR 92008 760730-3109 Plan Check Fee $0.00 Additional Fees $0.00 Total Fees: $0.00 Total Payments To Date: $143.48 Balance Due: ($143.48) FINAL APPROVAL Inspector: Date: Clearance: NOTICE: Please take NOTICE lhat approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as lees/exactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any tees/exactions of which vou have previously been given a NOT!C_E_similar to this, or asJo which the statute of limitations has previously otherwise expired. PERMIT APPLICATI CITY OF CARLSBAD BUILDING DEPARTMENT 1635 Faraday Ave., Carlsbad, CA 92008 FOR OFFICE USE ONLY PLAN CHECK NO. EST. VAL. Plan Ck. Deposit Validated By „ Date 08/24/04 OQQ2 01 Address {include Bldg/Suite #)Business Name latythis address)CGF 143-48 Legal Description Lot No.Subdivision Name/Number Unit No.Phase No.Total # of units Assessor's Parcel #Existing Use Proposed Use 2. CDNJACT PERSON fif diff Name Address &':\, APPLICANT Q Contractor D Agent for Address City State/Zip Telephone (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law (Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code) or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars [$500]}. Name State License # Address License Class City State/Zip City Business License # Telephone # Designer Name State License # Address City State/Zip Telephone $;JINKERS' COMPENSATION^ -....' • . ..•:'..:. • ' ..'-,-" .-.-.••• . • ' ;:• :•••:•.." - Worjcers' Compensation Declaration: I hereby affirm under penalty of perjury one of the following declarations: 0T I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. n I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My worker's compensation insurance carrier and policy number are: Insurance Company Policy No. Expiration Date (THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS [$100] OR LESS) Q CERTIFICATE OF EXEMPTION: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. WARNING: Failure to secure workers' compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars ($100,000), in addition to the cost of compensation, damages as provided for in Section 3706 of the Labor code, interest and attorney's fees. SIGNATURE DATE 7. OWNER-BUILDER DECLARATION I hereby affirm that I am exempt from the Contractor's License Law for the following reason: n I- as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). Q I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). Q I am exempt under Section Business and Professions Code for this reason: 1. I personally plan to provide the major labor and materials for construction of the proposed property improvement. Q YES QNO 2. 1 (have / have not) signed an application for a building permit for the proposed work. 3. I have contracted with the following person (firm) to provide the proposed construction (include name / address / phone number / contractors license number): 4. I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone number / contractors license number): 5. I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone number / type of work): PROPERTY OWNER SIGNATURE DATE COMPtETE THIS SECTIONFOR NON-HESIOENTIAl, BUILDING PERMITS ONLY Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration former risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? O YES B^rJO Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? O Y£S Q^NO Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? l~l YES Pi NO IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. I hereby affirm that there is a construction lending agency for the performance of the work for which this permit iaiesued (See. 3097{i) Civil Code). --—•••' fiifaLENDER'S LENDER'S ADDRESS I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all City ordinances and State laws relating to building construction. I hereby authorize representatives of the City of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: An OSHA permit is required for excavations over 5'0" deep and demolition or construction of structures over 3 stories in height. EXPIRATION: Every permit issued by the balding Official under/4he provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is not c^mm£Q«&rwith/nXfO/aays from the date of such permit or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commence#iQrj)j|Wiiji^ JSQ^ftys (Section 106.4.4 Uniform Building Code). APPLICANT'S SIGNATURE DATE WHITE: File YELLOW: Applicant PINK: Finance EsGil Corporation In (Partnership with government for Quitting Safety DATE: 11/29/04 Q JURISDICTION: City of Carlsbad Q PKNREVIEWER Q FILE PLAN CHECK NO.: PC04-0100 SET: III PROJECT ADDRESS: 2744 Carlsbad Blvd PROJECT NAME: Village by the Sea - TI The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. X] The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified in the remarks below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: Esgil Corporation staff did not advise the applicant that the plan check has been completed. Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Telephone #: Date contacted: (by: ) Fax #: Mail Telephone Fax In Person X] REMARKS: The applicant did not resubmit complete sets of plans. The applicant shall provide identical the plumbing, electrical and mechanical plans.i\T\ ^i^j^/ By: Doug Moody Enclosures: Esgil Corporation D GA D MB D EJ D PC 11/18/04 trnsmtl.dot 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 * (858)560-1468 + Fax (858) 560-1576 EsGil Corporation In Partnership witR government for (Buidfing Safety DATE: 10/29/04 a APPLICANT JURISDICTION: City of Carlsbad a PLAN REVIEWER a FILE PLAN CHECK NO.: PCO4-0100 SET: II PROJECT ADDRESS: 2744 Carlsbad Blvd PROJECT NAME: Village by the Sea - TI The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. XI The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. XI The applicant's copy of the check list has been sent to: Aaron Galaudel 539 Carlsbad Village Dr Suite 100, Carlsbad, CA 92008 Esgil Corporation staff did not advise the applicant that the plan check has been completed. XI Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Aaron Galaudel Telephone #: 310-345-3621 Date contacted: ^/^i/cY(by^S ) Fax #: 7£ 0-7 SO - 3 I tJQ/ / .^ 'Mail I'Telephone r Fax r In Person REMARKS: By: Doug Moody Enclosures: Esgil Corporation D GA D MB D EJ D PC 10/21/04 trnsmU.dot 9320 Chesapeake Drive, Suite 208 4- San Diego, California 92123 + (858)560-1468 4 Fax (858) 560-1576 City of Carlsbad PCO4-0100 10/29/04 RECHECK PLAN CORRECTION LIST JURISDICTION: City of Carlsbad PLAN CHECK NO.: PC04-0100 PROJECT ADDRESS: 2744 Carlsbad Blvd SET: II DATE PLAN RECEIVED BY DATE RECHECK COMPLETED: ESGIL CORPORATION: 10/21/04 10/29/04 REVIEWED BY: Doug Moody FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and disabled access. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department or other departments. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. A. Please make all corrections on the original tracings and submit three new sets of prints to: ESGIL CORPORATION. B. To facilitate rechecking, please identify, next to each item, the sheet of the plans upon which each correction on this sheet has been made and return this sheet with the revised plans. C. The following items have not been resolved from the previous plan reviews. The original correction number has been given for your reference. In case you did not keep a copy of the prior correction list, we have enclosed those pages containing the outstanding corrections. Please contact me if you have any questions regarding these items. D. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located on the plans. Have changes been made not resulting from this list? QYes QNo City of Carlsbad PC04-0100 10/29/04 These corrections are in response to items not fully addressed or as the result of information provided, the text in bold print indicates the unresolved issue. 2. On the first sheet of the plans indicate: • The total floor area of the remodeled area, The total area of all tenant spaces. 3. Specify on the plans the fire ratings of assemblies to protect penetrations or proposed openings in existing or new fire walls, floor-ceiling assemblies or roof-ceiling assemblies. Unless the penetrations were installed as part of the previous permit complete details are required to be shown for all penetrations which are part of this permit. 9. Please provide details of the duct protection for the penetrations of the 1 hour floor/ceiling and ceiling/roof assemblies. See comment 3. 10. The completed and signed ENV-1, LTG-1, and MECH-1 forms must be imprinted on the plans. The PERF-1 document and the LTG document which are imprinted on the plans must be signed by the document author and principle designer. 19. Show that grab bars comply with the following, per Section 1115B.8: The detail still shows the side grab bar mounted at 36" please correct. a) They shall be securely attached 33" above the floor, and parallel. NOTE: Where a tank-type toilet is used which obstructs placement of the rear grab bar at 33", the rear grab bar only may be installed as high as 36". The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Doug Moody at Esgil Corporation. Thank you. EsGil Corporation In Partnership witfi government for (BuiCding Safety DATE: 9/7/O4 OAEELICANT JURISDICTION: City of Carlsbad a PLAN REVIEWER a FILE PLAN CHECK NO.: PC04-0100 SET: I PROJECT ADDRESS: 2744 Carlsbad Blvd PROJECT NAME: Village by the Sea - TI The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. X] The applicant's copy of the check list has been sent to: Aaron Galaudel 539 Carlsbad Village Dr Suite 100, Carlsbad, CA 92008 Esgil Corporation staff did not advise the applicant that the plan check has been completed. Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Aaron Galaudel Telephone #: 310-345-3621 Date contacted: 1/$/<tf (by:tj£o Fax #: ffiO - *}3c) — 3/Vf^^ I/ ^*LMail--xielephone"-/ Fax^-—In Person REMARKS: By: Doug Moody Enclosures: Esgil Corporation D GA D MB D EJ D PC 8/26/04 trnsmU.dot 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 * (858)560-1468 + Fax (858) 560-1576 City of Carlsbad PC04-0100 9/7/04 PLAN REVIEW CORRECTION LIST TENANT IMPROVEMENTS PLAN CHECK NO.: PCO4-0100 OCCUPANCY: M TYPE OF CONSTRUCTION: V1H ALLOWABLE FLOOR AREA: SPRINKLERS?: Unknown REMARKS: DATE PLANS RECEIVED BY JURISDICTION: 8/24/04 DATE INITIAL PLAN REVIEW COMPLETED: 9/7/04 JURISDICTION: City of Carlsbad USE: Retail ACTUAL AREA: 8350sf STORIES: 1 HEIGHT: OCCUPANT LOAD: 278 DATE PLANS RECEIVED BY ESGIL CORPORATION: 8/26/04 PLAN REVIEWER: Doug Moody FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department, You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Code sections cited are based on the 1997 UBC. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans. TENANT IMPROVEMENTS WITHOUT SPECIFIC ENERGY DATA OR POLICY SUPPLEMENTS (1997UBC)tiforw.dot City of Carlsbad PC04-0100 9/7/04 Please make all corrections on the original tracings, as requested in the correction list. Submit three sets of plans for commercial/industrial projects (two sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. Generally the plans are incomplete and a thorough plan check can not be done, the following list is a general list only and corrections may follow. 1. Provide a statement on the Title Sheet of the plans stating that this project shall comply with the 2001 edition of the California Building Code (Title 24), which adopts the 1997 UBC, 2000 UMC, 2000 UPC and the 1999 NEC. 2. On the first sheet of the plans indicate: • The total floor area of the remodeled area, • Sprinklers: Yes or No 3. Specify on the plans the fire ratings of assemblies to protect penetrations or proposed openings in existing or new fire walls, floor-ceiling assemblies or roof-ceiling assemblies. 4. Please clarify the section view of all new interior partitions. Show: a) Specify manufacturer and approval number or indicate "to be ICBO approved". b) Method of attaching top and bottom plates to structure. (NOTE: Top of partition must be secured to roof or floor framing, unless suspended ceiling has been designed for partition lateral load). c) Show height of partition and suspended ceiling, and height from floor to roof framing or floor framing. 5. Please note on the plans "AC Cable is not allowed in A, B, E, H, and I occupancies. NM cable is restricted (without City approval) to one and two family dwellings. Note on plans that an equipment ground conductor is to be installed in all flexible conduits". 6. Please provide panel schedules, indicate new and existing loads. City of Carlsbad PC04-0100 9/7/04 7. Please provide an electrical single line diagram. Show new or existing distribution equipment, ampere size and AIC rating of distribution equipment, feeder over-current devices size and indicate AIC rating, conduit and conductor size and length, sub-service ampere rating and AIC rating, transformer KVA size and grounding conductor and grounding location. 8. Provide mechanical plans, showing existing and proposed HVAC equipment, ducts and access to equipment. 9. Please provide details of the duct protection for the penetrations of the 1hour floor/ceiling and ceiling/roof assemblies. 10. Provide mechanical ventilation in all rooms, capable of supplying outside air at a minimum rate of 15 cubic feet per minute per occupant. UBC, Section 1202.2.1. 11. Provide complete plumbing plans, including: a) Complete drain, waste and vent plans. b) Provide complete water line sizing calculations, including the water pressure, pressure losses, water demands, and developed pipe lengths. UPC Section 610.0 c) Show water heater size, type and location on plans. UPC, Section 501.0 12. Show 1/4" per 12" slope on drain and waste lines. UPC Section 708.0. 13. Note on the plans that new water closets and associated flushometer valves, if any, shall use no more than 1.6 gallons per flush and shall meet performance standards established by the American National Standards Institute Standard A112.19.2. H & S Code, Section 17921.3(b). 14. Provide complete energy designs for the proposed changes in envelope, lighting, and mechanical systems. Provide the completed ENV-, LTG-, and MECH- forms showing energy compliance. 15. On the plans clearly show the wall and roof insulation locations, thickness, and R-values, as per the energy design. 16. The completed and signed ENV-1, LTG-1, and MECH-1 forms must be imprinted on the plans. 17. When alterations, structural repairs or modifications or additions are made to an existing building, that building, or portion of the building affected, is required to comply with all of the requirements for new buildings, per Section 1134B.2. These requirements apply as follows: a) A primary entrance to the building and the primary path of travel to the altered area, must be shown to comply with all accessibility features. City of Carlsbad PC04-O100 9/7/04 18. Show on the site plan the complying disabled accessible path of travel from the disabled accessible parking spaces to the primary entrance of the tenant space. Please provide detailed plans of the path of travel, indicate slope and width, any pedestrian ramps, curb ramps, walks, handrails, provide dimensioned parking stall details etc. 19. Show that grab bars comply with the following, per Section 1115B.8: a) They shall be securely attached 33" above the floor, and parallel. NOTE: Where a tank-type toilet is used which obstructs placement of the rear grab bar at 33", the rear grab bar only may be installed as high as 36". To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please indicate: Yes Q No Q The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Doug Moody at Esgil Corporation. Thank you. City of Carlsbad PC04-0100 9/7/04 VALUATION AND PLAN CHECK FEE JURISDICTION: City of Carlsbad PREPARED BY: Doug Moody BUILDING ADDRESS: 2744 Carlsbad Blvd PLAN CHECK NO.: PC04-010O DATE: 9/7/04 BUILDING OCCUPANCY: M TYPE OF CONSTRUCTION: V1H BUILDING PORTION Tl Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code AREA ( Sq. Ft.) 8350 cb Valuation Multiplier 30.00 By Ordinance Reg. Mod. VALUE ($) 250,500 250,500 1994 UBC Building Permit Fee 1994 UBC Plan Check Fee Type of Review: O Repetitive Fee Repeats 0 Complete Review D Other r-i Hourly Structural Only Hour Esgll Plan Review Fee $1,011.64 $657.57 $566.52 Comments: Sheet 1 of 1 macvalue.doc PLANNING/ENGINEERING APPROVALS PERMIT NUMBER CB ADDRESS DATE RESIDENTIAL RESIDENTIAL ADDITION MINOR « $1O,OOO.OO) TENANT IMPROVEMENT.1 PLAZA CAMIKQKEAE . : CARLSBAD COMPANY STORES VILLAGE FAIRE COMPLETE OFFICE.BUILDINC OTHER -fu** PLANNER ENGINEER DATE DATE oocs/MlsformyPlannlng Engineering Approvals September 3, 2004 TO: BUILDING DEPARTMENT FROM: Management Analyst, Redevelopment Department LACUNA POINT - PLAN CHECK NO. PC040100. I have reviewed and approved the building plans for the above referenced project. This information has been entered into Permits Plus. If you have any questions, please contact me at x2817. I//- RUE Carlsbad Fire Department 040100 1635 Faraday Ave. Carlsbad, CA 92008 Plan Revjew Requirements Category: Date of Report: Q8/3Q/2004 Fire Prevention (760) 602-4660 Building Plan Reviewed by: Name: Address: City, State: Aaron Gacaudet 539 Carlsbad Village Dr. Suite 1 00 Carlsbad CA 92008 Plan Checker: Job Name: Village by the Sea Job#: 040100 Job Address: 2744 Carlsbad Blvd. D Bldg #: PC040100 Ste. or Bldg. No. Approved The item you have submitted for review has been approved. The approval is based on plans, information and / or specifications provided in your submittal; therefore any changes to these items after this date, including field modifications, must be reviewed by this office to insure continued conformance with applicable codes and standards. Please review carefully all comments attached as failure to comply with instructions in this report can result in suspension of permit to construct or install improvements. Approved Subject to The item you have submitted for review has been approved subject to the attached conditions. The approval is based on plans, information and/or specifications provided in your submittal. Please review carefully all comments attached, as failure to comply with instructions in this report can result in suspension of permit to construct or install improvements. Please resubmit to this office the necessary plans and / or specifications required to indicate compliance with applicable codes and standards. Incomplete The item you have submitted for review is incomplete. At this time, this office cannot adequately conduct a review to determine compliance with the applicable codes and / or standards. Please review carefully all comments attached. Please resubmit the necessary plans and / or specifications to this office for review and approval. Review FD Job # 1 st 2rH 3rri 040100 FDFile# other Agency in Requirements Category:Building Plan Requirement: Pending 05.11 Knox Box Knox Box required when access to or within a structure or an area is unduly difficult because of secured openings or where immediate access is necessary for life saving or fire-fighting purposes. The Fire Department will determine the location for the key box and provide an authorized order form. FIRE shall require the installation of KNOX key boxes in two central locations to serve no more than four units. Please contact this office for ordering information at 760.602.4665. Requirement: Pending 05.16 A/S Design Sprinkler system design shall be in accordance with standards set forth by the National Fire Protection Association and UBC Standards 38-1 and 38-2. Permits are required prior to installation. Plans, specifications and calculations shall be certified by a licensed fire protection engineer or other person deemed competent by the Chief, and submitted in the name of a licensed sprinkler contractor. Warehouse buildings for which no specific use, occupant, product, activity or storage array has been identified, shall be protected by sprinkler system designed to deliver water at the rate of .45 gallons per square foot, throughout a 3000 square foot design area. FIRE shall require plans for the reflected ceiling fire sprinkler installation if not already approved. Requirement: Pending 05.18 Fire Extinguishers Required Provide one 2A10BC fire extinguisher for each 6000 square feet or portion thereof with a travel distance to the nearest extinguisher not to exceed 75 feet of travel. Provide notes on the plans that the extinguisher will be provided. Requirement: Pending 05.22 Exit Door Hardware Exit doors shall be openable from the inside without the use of a key or any special knowledge or effort. Exception: In group B occupancies, key locking hardware may be used on the Main Exit when the main exit consists of a single door or pair of doors if there is a readily visible, durable sign on or adjacent to the door stating, "This door to remain unlocked during business hours." For State Fire Marshal, sign shall read, "This door to remain unlocked whenever the building is occupied." See item 32 for additional exit door hardware requirements. Exit door locks shall be Double cylinder deadbolts. Page 1 08/30/04 ASTASl October 18, 2004 DEVELOPMENT COMPANY, LLC John's Copy City of Carlsbad Dept of Building and Safety Re: PC04-100 Village by the Sea Tl Resubmittal Plan Package Please find enclosed plan check corrections from our submittal dated 9/7/04. Enclosed herewith: 1 set corrected plan submittal (delta 2) 1 set Newton Energy Title 24 Reports 1 set Electrical Plans 1 set Mechanical Plans 1 set Plumbing Plans 1 set City approved Landscape Plan (prior approval) 1 set City approved Improvement Plan (prior approval) Please contact John Simons when you have reviewed the plans and are ready for Permit. If you have any questions, please call our Construction Manager, Larry Lewis at (310)345-3607. Sine Joon Simons Anastasi Development 539 Carlsbad Village Dr., Suite 100, Carlsbad, C A 92008 Tel. (760} 729-6865 -Fax (760) 729-7195 TITLE 24 REPORT Title 24 Report for: Retail Space T. I. @ The Village by the Sea Carlsbad Blvd. Carlsbad, CA Project Designer: Anastasi Development Corporation 1200 Aviation Blvd. #100 Redondo Beach, CA 90278 (310)376-8077 Report Prepared By: Chad Campbell NEWTON ENERGY 24050 Madison Street #209 Torrance, CA 90505 (310)375-2699 Job Number: 4588NR Date: 9/30/2004 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2001 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC (415) 883-5900. EnergyPro 3.1 By EnergySoft Job Number: 4588NR UserNumber: 2100 j1 -<& #. 0 '* flr^-b~$ ;.cs*t *JK~ '»J- ^ !-Jta ^'e ^ 'v Q \; ^. ^ ^ > ^_i- % V 1 f^ J^fU '/v ^- : S ' ' <^: °.?1 1 "j1-V"S? i *^*>v! ^ ^ ' **C «t>:V •* ^'• 0 i ^: i ; 1 1t^ t <• j1 •* VS rr : o^|^M ! -^ ^ ' t,K; ^ _> I 0 Si ^ •P >>;; ' &•N,• "2 r^- ^; t- ^ :2 ^i ^ <*^ ^v^^ ^ 0 9 ," K V' -J-a 7,'3 \ . 41 \>'^ li«L'-t L z<c_ja iii oc I-oLU H £ooc cr