HomeMy WebLinkAbout2746 LOKER AVE W; ; CB041510; PermitCity of Carlsbad
1635 Faraday Av Carlsbad, CA 92008
Commercial/Industrial Permit Permit No:
Building Inspection Request Line (760) 602-2725
CB041510
Job Address: 2746 LOKER AV WEST CBAD
Permit Type:
Parcel No:
Valuation:
Occupancy Group:
Project Title:
Tl Sub Type:
2090810700 Lot#:
$1,600.00 Construction Type:
Reference #:
MO-BIO LABS-INSTALL ELECTRIC
DOOR HARDWARE
INDUST
0
NEW
Status:
Applied:
Entered By:
Plan Approved:
Issued:
Inspect Area:
Plan Check#:
ISSUED
05/05/2004
KMT
06/23/2004
06/23/2004
Applicant: Owner:
JMG SECURITY
17150 NEWHOPE
SUITE 109
92008
800-900-4564 EXT.316
Buildin·g Permit
Add'I Building Permit Fee
Plan Check
Add'I Plan Check Fee
Plan Check Discount
Strong Motion Fee
Park Fee
LFM Fee
Bridge Fee
STD #2 Fee
STD #3 Fee
Renewal Fee
Add'I Renewal Fee
Other Building Fee
Pot. Water Con. Fee
Meter Size ·
Add'I Pot. Water Con. Fee
Reel. Water· Con. Fee
Total Fees: $72.83
$31.41
$0.00
$20.42
$0.00
$0.00
$1.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
CANYON RIDGE BUSINESS PARK LL C
4510 EXECUTIVE DR PLAZA 5
SAN DIEGO CA 92121
Meter Size
Add'I Reel. Water Con. Fee
Meter Fee
SDCWAFee
CFO Payoff Fee
PFF
PFF (CFO Fund)
License Tax
License Tax (CFO Fund)
Traffic Impact Fee
Traffic Impact (CFO Fund)
PLUMBING TOTAL
ELECTRICAL TOTAL
MECHANICAL TOTAL
Master Drainage Fee
Sewer Fee
Redev Parking Fee
Additional Fees
TOTAL PERMIT FEES
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$20.00
$0.00
$0.00
$0.00
$0.00
$0.00
$72.83
Total Payments To Date: $0.00 Balance Due: $72.83
5028 06/23/04 0002 01 02
C:GP 72,,83
DA\t,Jq/(Jcj CLEARANCE
SIGNA;;;r-r: ::, ----
FOR OFFICE USE ONLY
PERMIT APPLJCATION PLAN CHEC[t, No.C.,OOL{ 1510
EST. VAL. /,~ CITY OF CARLSBAD BUILDING DEPARTMENT
1635 Faraday Ave., Carlsbad, CA 92008 Plan Ck. Deposit ~,....,...e:;._-~----
Valida:i Bt
Date 5. 5i DY
Legal Description Lot No. Subdivision Name/Number Unit No. Phase No. Total # of units
7,5t0 ¢1 tlreP
#of Stories # of Bathrooms
Telephone # Fax#
·-".c:-----·,"_:--': ·.:· m\ke...··-----·
, . ?,_Oc...: lffbi/ 3U
City State/Zip Telephone #
fJ-7-'1t_c_ L~tJi: . ft/4~--·----ile_ • .i.s4/· -?:J.ri'c-J t?:i.jj i<t ~~ ~ ~ 'tt I --
Name Address City S.tate/Zip Telephone#
~!?;, -<fON'fMQTQB.· GQMJ18NYJI.IAM,;.-. · ·., · , ----~·.:::" -_ .... -· -· ,,
(Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its
issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law
[Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code] or that he is exempt therefrom, and the basis for the alleged
exemption. Any violation of Section 7031.5 by any applicant r a permit subjects the applicant to a civil pen It of et more than fiv hundr,ed dollars [$50~1.J;,
0 ~ t,1 qQ;J-tf-~
Designer Name Address City State/Zip Telephone
State License # _________ _
;_~, WQF,t!{EF,tS'. QOr,'IPEN,SATJON : . , . , . " , . -. -',, ~ ,-· -'"' ...
Workers' Compensation Declaration: I hereby affirm under penalty of perjury one of the following declarations:
9,--I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance
of the work for which this permit is issued. 9'--I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is
issued. My worker's c mRensation insurance carrier and polic~ber are: ,.,-, \\L l
Insurance Company 1S""f'""' C -Policy No. C. ;.J... d q O O 3 ? f ::::sJ__ Expiration Date er_/_ 0 lf
(THIS SECTION NEED NOT BE COMPLETED IF THE PER IT IS FOR ONE HUNDRED DOLLARS ($100) OR LESS}
0 CERTIFICATE OF EXEMPTION: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as
to become subject to the Workers' Compensation Laws of California.
WARNING: Failure to s ure workers' compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred
thousand dollars($ 00), in ad • 10n to cost sation, damages as provided for in Section 3706 of the La7de, inte:~ and attorney's fees.
SIGNATURE_--;,:(&-Jr,,c....:,"""""+-~'7"°'""""'---4--'------------DATE 6,p-:-o?..2i?,_t-2~
;7,·-:_Q\ll/f!f,:~-!1lLD.lllQEC.tAfl)\T _ .. _ .. ._·_· .. ,._,_. " .. , ..... .'.;,'.., · -_· __ ,:.:,,, ,. , -
I hereby affirm that I am exempt f om the Contractor's License Law for the following reason:
0 I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale
(Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does
such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is
sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale).
0 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The
Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed
pursuant to the Contractor's License Law).
0 I am exempt under Section ______ Business and Professions Code for this reason:
1. I personally plan to provide the major labor and materials for construction of the proposed property improvement. 0 YES ONO
2. I (have / have not) signed an application for a building permit for the proposed work.
3. I have contracted with the following person (firm) to provide the proposed construction (include name / address / phone number / contractors license number):
4. I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone
number/ contractors license number): _____________________________________________ _
5. I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone number / type of work): _______________________________________________________ _
DATE -----------
Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention
program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? 0 YES O NO
ls the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? 0 YES O NO
ls the facility to be constructed within 1,000 feet of the outer boundary of a school site? 0 YES O NO
IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE
REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT.
fS<: ;,,&Q.N$TR~~tlO,fifet,tQ!ijG)[~l:J'tCX .: .. -.. -.. :<.:. ... s ,-. ; -~-, ., •• --.. ~-'-~'.:.:. . .'-• .':-... :. ·::~:' '; __ ,:· :,, ,:_-,·:,_:: ·_-_-,,_-_ ~-_,,,, -. : :: _; _:;~--
1 hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097(i) Civil Code).
LENDER'S ADDRESS LENDER'S NAME _____________ _ ----------------------------!~. . -A!:'P.!;JQJ.\NI: Cl:R1'!1:IPAJ!QNi: .. : : -·· '._,,, -, , r--. < ;
I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all
City ordinances and State laws relating to building construction. I hereby authorize representatives of the Cit~ of Carlsbad to enter upon the above mentioned
property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES,
JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT.
OSHA: An OSHA permit is required for excavations over 5'0" deep and demolition or construction of structures over 3 stories in height.
EXPIRATION: Every permit issued by the building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work
authorized by such permit is not comm need within 180 da s from e date of such permit or if the building or work authorized by such permit is suspended or abandoned
at any time after the work is co~ ed to.1: a period o Oday S ion 10 niform Building Code). , /"_/:.
APPLICANT'S SIGNATURE ~ DATE if"/570£;' 7 IY
PINK: Finance
\\~ 1 fG
City of Carlsbad Bldg Inspection Request
For: 12/08/2004
Permit# CB041510
Title: MO-BIO LABS-INST ALL ELECTRIC
Description: DOOR HARDWARE
Type: Tl
Job Address:
Sub Type: INDUST
2746 LOKER AV WEST
Suite:
Location:
APPLICANT JMG SECURITY
Owner:
Lot 0
Remarks: ELECT DR HARDWARE FOR FINAL
Total Time:
CD Description ]J;E_Commenl
19 Final Structural
T
~
29 Final Plumbing ftd2--39 Finai Electrical
49 Final Mechanical
Associated PCRs/CVs
Inspector Assignment: PC ---
Phone: 7604978820
Inspector: f7C/
Requested By: MIKE
Entered By: KAREN
PCR03229 ISSUED CARLSBAD OAKS BLDG C; Q.C. CORRECTIONS & ROOF FRAMING REV
PCR03245 ISSUED CARLSBAD OAKS BLDG C; REV JAMB REIFORCEMENT
Date Description
11/23/2004 35 Fixtures
Inspection History
Act lnsp Comments
CA PC
CIIY DI Carlsbad
· Final Building Inspection
Dept: Building Engineering Planning CMWD St Lite fire
Plan Check #:
Permit#:
Project Name:
CB041510
MO-BIO LABS-INSTALL ELECTRIC
DOOR HARDWARE
Address: 2746 LOKER AV WEST
Contact Person: MIKE Phone: 7604978820
SewerDi!?t: CA Water Dist: CA
Date: 12/08/2004
Permit Type: Tl
Sub Type: INDUST
Lot: 0
..........................................................................................................................................................
:;pectet? zJ;t/~ Date ;J/"-r 3jb_r_ Approved: Inspected: ~ Disapproved: __
Inspected Date
By: Inspected: Approved: Disapproved: __
Inspected Date
By: Inspected: Approved: Disapproved: __ ...........................................................................................................................................................
Comments: -------------------------------
•
DATE: May 11, 2004
JURISDICTION: Carlsbad
PLAN CHECK NO.: 04-1510
I
EsGil Corporation
In Partnersliip witli (jovemment for 'BuiCaing Safety
SET:I
PROJECT ADDRESS: 2746 Loker Ave. West
PROJECT NAME: Electronic Door Hardware
_9-AeeL!QANT
/~
D PLAN REVIEWER
D FILE
cg] The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes.
D The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff.
D The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
D The check list transmitted herewith is for your information. The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck.
D The applicant's copy of the check list is enclosed for the jurfsdiction to forward to the applicant
contact person.
D The applicant's copy of the .check list has been sent to:
IZJ Esgil Corporation staff did not advise the applicant that the plan check has been completed.
D Esgil Corporation staff did advise the applicant that the plan check has been completed.
Person contacted: Telephone#:
Date contacted: (by: ) Fax#:
Mail Telephone Fax In Person
D REMARKS:
By: Kurt Culver Enclosures:
Esgil Corporation
D GA D MB D EJ 0 PC 5/6/04 tmsmtl.dot
9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858) 560-1468 + Fax (858) 560-1576
Carlsbad 04-1510
May 11, 2004
iVALUATION AND PLAN CHECK FEE
JURISDICTION: Carlsbad PLAN CHECK NO.: 04-1510
PREPARED BY: Kurt Culver DATE: May 11, 2004
BUILDING ADDRESS: 2746 Loker Ave. West
BUILDING OCCUPANCY: B TYPE OF CONSTRUCTION: V-N
BUILDING AREA Valuation Reg. VALUE
PORTION (Sq.Ft.) Multiplier Mod.
Door Hdwe.
Air Conditioning
Fire Sprinklers
TOTAL VALUE
Jurisdiction Code cb By Ordinance
Bldg. Permit Fee by Ordinance j ..-1
Plan Check Fee by Ordinance J ... j
Type of Review: 0 Complete Review D Structural Only
D Repetitive Fee CG Repeats
Comments:
D Other
D Hourly I Hour *
Esgil Plan Review Fee
($)
1,600
1,600
$33.09j
$21.51 I
$18.531
Sheet 1 of 1
macvalue.doc
Carlsbad Fire Department 041510
1635 Faraday,Ave.
Carlsbad, CA 92008
Plan Review Requirements Category:
Fire Prevention
(760) 602-4660
Date of Report: _06_1_01_12_0_0_4 _______ _
Building Plan
Reviewed by:
Name: JMG Security Systems
Address: 17150 Newhope St Ste 109
City, State: Fountain Valley CA 92708
Plan Checker: Job#: 041510 -------
Job Name: Mo-Bio Labs Bldg#: CB041510 ------------------
Job Address: 2746 Loker Ave. w Ste. or Bldg. No.
~ Approved
D Approved
Subject to
D Incomplete
Review
FD Job#
The item you have submitted for review has been approved. The approval is
based on plans, information and/ or specifications provided in your submittal;
therefore any changes to these items after this date, including field
modifications, must be reviewed by this office to insure continued conformance
with applicable codes and standards. Please review carefully all comments
attached as failure to comply with instructions in this report can result in
suspension of permit to construct or install improvements.
The item you have submitted for review has been approved subject to the
attached conditions. The approval is based on plans, information and/or
specifications provided in your submittal. Please review carefully all comments
attached, as failure to comply with instructions in this report can result in
suspension of permit to construct or install improvements. Please resubmit to
this office the necessary plans and / or specifications required to indicate
compliance with applicable codes and standards.
The item you have submitted for review is incomplete. At this time, this office
cannot adequately conduct a review to determine compliance with the
applicable codes and / or standards. Please review carefully all comments
attached. Please resubmit the necessary plans and / or specifications to this
office for review and approval.
1st
041510
2nd
FD File#
3rd Other Agency ID
, .~ ,~ • Burglar Alarm • Fire Alarm • CCTV • Access Control
SECURITY SYSTEMS I I I I I I I I ·
Securing Southern California
May 3, 2004
City of Carlsbad
1535 Faraday Ave.
Carlsbad,CA.92008
RE: Door Hardware·submittal Package
MO-BIO LABORATORIES
2746 LOKER AVE. EAST
CARLSBAD, CA. 92008
Enclosed are hardware specifications for the installation of a card access control system
for the company listed above.
The door hardware is as follows:
• Door # 1 -Main lobby entry double door Adams Rite 8600 series with no delayed
egress these are mechanical/electric panic devices
• Power -Adams Rite PS-I power supply 12/24 VDC 1 AMP with no battery
backup.
Please contact Mike Tremblay JMG Security 17150 New hope Street # 109 Fountain
Valley, CA. 92708 with any questions at (760) 497-8820.
Thank you.
TEL: (714) 545-8882 • FAX: (714) 545-0352 • 17150 Newhope St., Suite 109 • Fountain Valley, CA 92708
Alarm License AC03759 • Contractor's License No. 575070 C Bo .., I S' to
JMs-o ti1dvailable
foli' a Mirdlpanel
door design
CERTIFICATIONS:
@Life-Safety Listing
ANSI/BHMAA156.3 Grade 1
California State Fire Marshall
New York City MEA *
•consult tactory for specific number
~ ADAMS RITE
~ MANUFACTURING CO.
Narrow Stile
Concealed Vertical
Rod Exit Device
For Aluminum Doors
8600 Series
LIFE-SAFETY
0
Features:
V Patented top latching
mechanism inter!ocks door
to frame
TTop and bottom adjustable
steel rods
w Pushbar anodized or dad, not
plated, in a variety of finishes
v Easy to install
Y Clean, unobtrusive design
'W Strong, durable construction
for a high level of security
260 Santa Fe Street
Pomona, California 917 67
/800) 872-3267 Fax:/800) 232-7329
www.adamsrite.com
ED-6
;"."•
,,
ADAMS RITE MANUFACTURING· CO·.
1 AMP Ll·N:EAR POWER SU'PPL Y
MODE.L PS-1 PART No. 29-0615
POWER SU·PPL Y INSTRUCTION MANUAL
DOCUMEN·T NUM:BER 80-01-80-288
I PHYSICAL FEATURES J I POWER SUPPL y DESCRIPTION
SCREW
DOWN COVER ,
0
12" l
I '7
OPTIONAL STANDBY BATTERIES
POWER SUPPLY BOARD FEATURES
I GENERAL SPECIFICATIONS
ELECTRICAL SPECIFICATIONS
INPUT POWER: 110 VAC, 60 Hz, 600 mA
OUTPUT VOLTAGE: Filtered, Regulated
13.8 VDC or 27.6 VDC
(Field Jumper Selectable)
MAX OUTPUT CURRENT: 1 AMP
CHARGING CIRCUIT: Built-in, standard.
CHARGING TIME: Approx. 48 Hours from discharge.
PRIMARY FUSE: 800 mA, 5 x 20mm
BATTERY FUSE: 2 AMP, 5 x 20mm
TYPICAL AMBIENT OPERA TING
TEMPERATURE: 72 F, 20 C
SECONDARY PROTECTION: Voltage regulator
has inherent overload protection and will
shutdown in the event of overheating.
This power supply is a field selectable 12 / 24 voe regulated
power supply. When backup batteries are supplied, the unit
serves as an uninterruptable power supply, maintaining output
power during power outages. With line power applied, a LED on
the power supply circuit board will be illuminated. This LED
Indicates that output power Is present at both the output and the
standby battery terminals. When batteries used and no line power
is present, the LED will also be illuminated, indicating that battery
voltage is present at the output. The unit has an automatic
charging circuit that will maintain battery charge.
MECHANICAL SPECIFICATIONS
ENCLOSURE: 12 "x 12 x 4" Steel NEMA Grade 1
with conduit knockouts and hinged
cover with lockdown screws.
WEIGHT (POWER SUPPLY): 8.0 lbs, 3.6 kg.
WEIGHT (EACH BATTERY): Approx 4 lbs, 1.8 kg.
INPUT TERMINALS: Barrier strip with (2) #6
screw terminals.
OUTPUT TERMINALS: Barrier strip with
(4) #6 screw terminals and
(4) quick connect terminals.
OPTIONS AVAILABLE
Standby Battery
Cable Kit
Enclosure Cover Key Lock
A/C Power Line Chord, 6 focit
THIS POWER SUPPLY IS INTENDED FOR USE IN A CONTROLLED ENVIRONMENT. Pg. 1
TEST INSTALLATION
STEP 5: With line power present, the LB)on the power supply circuit board should illuninate. This
indicates that low voltage pow er is present on terrrinal block 2 (TB2), terninals 1 and 4.
Locking systemshould operate according to selected system wiring diagram
If problems occur, check the "POWER SUPPLY TROUBLESHOOTING" section, page 6.
f STANDBY POV\ER OPTIONS
Standby batteries are supplied and packaged separately.
For 12 volt operation, one or two batteries rray be used.
For 24 volt operation, two batteries in series are required.
Since rrany electrorragnetic locks draw twice as rruch
current in 12 volt operation as corrpared to 24 volt
operation, we recommend using two parallel batteries in
the 12 volt operating nnde. This will provide suitable
backup tirre during power failure.
(1) Standby Battery (12 V 4Ah rechargeable
sealed lead acid.}
(1) Battery Cable Kit (12 or 24 volt installation)
I INSTALLATION: STANDBY -BATTERIES
STEP6: Turn off 110 VACline power to the power supply.
4 AMP/HOUR OUTPUT
STANDBY SYSTEM CURRENT TIME DRAW (AMP.Sf HOURS {12 OR 24 VOL ")
3 1.00
6 .50
8 .45
12 .33
18 .22
24 .16
36 .11
48 .09
STEP 7: Set batteries upright in bottom of pow er supply enclosure.
STEPS: Using the cable kit, ensure that the ccxrect wiring configuration is used for the selected
output voltage set in step 2.
B+ I ~B-1=~ I ~rr m,e-1=~ I
· \MiffE 1:.1 V\4-fffE l ~ l
I I
V\4-fffE BLK
I I __ ,..._;
BLK l l ....,_ ............ 1. •• + -+ -+ -: + -: I I I I I I
BATT1 BATT2 BATT1 : BATT2: I I -·-······
CAUTION: Rerrenber to observe the battery polarity! lrrproper battery connection
could cause personal injury or darrage to pow er supply corrponents.
BATTERY TESTS
SECOND OPTIONlt.
EWTERYTO
INCREASE TO 121/
8,l!f,OlJTPUT
With 110 VAC line voltage applied, the power supply recharging circuit can be checked for
proper operation. Using a voltrreter, rreasure the output voltage at the battery quick connect
terninals. 1\/eter reading, without batteries connected should be:
Approx. 13.8 VDC for 12 Volt operation
Approx. 27.6 VDC for 24 Volt operation
THIS SECTION CONTINUED ON NEXT PAGE Pg.4
]
LOCK SYSTEM WRING DIJ>GRAMS
FAIL-SECURE LOCKS
(OPEN CONTROL CONTJ!CTS)
FIGURE A
+ 1---0-...-0---1
AGURE~-= ---B==-d
FIGUREE CDIIID.1
+ 1---~o-----r--i
* SIN3LELOO<
*SIN3I..Ero-J:Jm..
* OJntrol wired along lock power fine -
Least arrount of conductas in wire run.
*SII\G..ELOO<
.. SIN3..Ero-J:Jm..
• Bach carponentwired
back to power supply-
provides a commn JUnction box for convenient hook-up and troul:ieshooling.
* IXU!LELOO< CR M.L llA.ESII\G..E LOO<S
* SII\G..Ero-J:Jm..
* Locks wired in parallel in vicinity ri locks.
* IXU!LELOO<CR M.L 11A..ESIN3I..E LOO<S
• SIN3I..Ea:Nl'R:l.
• Separate wire runs for
each lock-reduces vdtaoo crop and wire size for bngwireruns.
* M.L llR.ESII\G..ELOO<S
* Individual contrd for
each lock.
MONITORING SYSTl:M WRING
RGUREF .OOORSTATUS
+ l--1t-0-'l'l---r-.
RGUREG
,. '
, '
IXXRCHN
L
LOCKSTATUS
+ 1------0---0----r-:-.
AGUREH
DOOR & LOCK STATUS + 1----0---0----r-,
3 4
1. OOORQ.008:>&L<Xl®
2 OOORO'Ellffil.N..OO<ID
3. OOORSTAlUSS'MTO-l
4.LOO<STAlUSS'MTO-l
FAIL-SAFE LOCKS
(Cl.OSEDCONTROLCONTICTS)
FIGURE!
FIGUREJ
AGUREK
FIGUREL
FIGUREM
<Xl'IIRJ.1 + 1---0--"1>----r:-,
AGUREN
FIGUREO
IW\SlER
ro,nm_
<Xl'IIRJ.1
a=ur Cmtrol Switch for
sirrultaneous release of two
locks w~ "release delay''.
• SII\G..ELQCK
• S11\G..ECDIITRQ
*Q,ntrolwiredalong lock power line -
Least annunt of conductcrs in wire run.
*SN3LELOO<
• SN3LE<XNTRCl.
• B3ch carponent wired
back to power supply-
provides a comron )Unction box for
convenient hook-up and troul:ies~ling.
* ro.BLELOO< CR M.lllA..ESIN3I..E LOO<S
• SII\G..E<XNTRCl.
* Locks wired in parallel in vicinity of locks.
* ro.BLELOO< CR
M.l Tlf!.ESII\G..E LOO<S
* Sll\G..Ero-J:Jm..
• Separate wire runs for
each lock-reduces volta!:le crop and wire
size for bng wire runs.
• M.J.. TIA.ESIN3I..ELOO<S
• lncfJVidual contrd for
each lock.
* Ml. llA..ESII\G..ELOO<S
* Individual contrd for each .lock with II/aster O:>ntrol for both locks .• Mly be rraster errergency switch,
fire pans, etc.
O:casiofl!=lllY., two rragnelic locks released bv one contact will exhibit a
delay in the release
of one of the locks. If
this condtion is
()El[ceived as a Problem a a=ur switch should
be used to elirrinate
the delay.