HomeMy WebLinkAbout2747 LLAMA CT; ; 85-517; Permiti hereby affirm that I am licensed under
provisions of Chapter 9 (commencing with
Section 7000) of Division 3 of the Business
and Professions Code, and my license is in
full force and effect.
Lic No.________________ Class
I hereby affirm that I am exempt from the Contrac-
tots License Law for the following reason (Sec. 7031.5
Business and Professions Code: Any city or, county which re-
quires a permit to construct, alter, improve, demolish, or
repair any structure, prior toils issuance also requires the ap-
plicant for such permit to file a signed statement that he is
-licensed pursuant to the provisions of the Contractors
License Law (Chapter 9 commencing with Section 7000 of
Division 3 of the Business and Professions Code) or that is ex-
empt therefrom and the basis for the alleged edemption. Any
violation of Section 7031 .5 by an applicant for a permit sub-
jects the applicant to a civil penalty of not more than five hun-
dred dollars ($500).
O I, as owner of the property, or my employees with wages
as their sole compensation, will do the work, and the struc-
ture is not intended or uttered for sale (Soc. 7044, Business
and Professions Code: The Contractor's License Law does
not apply to an owner of property who builds or improves
thereon and who does such work himself or through his awn
employees, provided that such improvements are not intend-
ed or offered for sale. If, however, the building or improve-
ment is sold within one year of completion, the owner-builder
will have the burden of proving that he did not build or im-
prove for the purpose of sale).
D I, as owner of the property, am exclusively contracting
with licensed contractors to construct the project (Sec. 7044.
Business and Professions Code: The Contractor's License
Law dues not apply to an owner 01 property who builds or im-
proves thereon, and who contracts for each projects with a
contractor(s) license pursuant to the Contractors License Law).
As a homeowner lam improving my home, and the follow-
ing conditions exist:
t. The work is being performed prior to sale.
I have lived in my home for twelve months
prior to completion of this work,
I have not claimed this exemption during the
last three years.
lam exempt under Sec. __________________ , B& P.C.
for this reason 16
LI I hereby affirm that t have a certilicrconsem o
self.insure. or a Certiticate of Workers' v.
surance. or a certified cvyy thereof (Sec.e)
POLICY NO.
COMPANY
LI Copy is filed with the city
LI Certified copy is hereby furnished
CERTIFICATE OF EXEMPTION FROM
WORKERS COMPENSATION INSURANCE
This section need not be completed if the permit
is for one hundred dollars ($100) or less)
LI I certify that in the performance of the work for which
his permit is issued. I shall not employ any person in any
manner so as to become subject lathe Workers' Compen-
sation Laws of California,
NOTICE TO APPLICANT: It, after making this Certificate
of Exemption, you should became subject to the Workers'
Compensation provisions 01 the Labor Code, you must
forthwith comply with Such provisions or this permit shall
be deemed revoked.
LI I hereby affirm that there is a construction lending
agency for the performance of the work for which this per-
mit is issued (Sec. 3097, Civil Code)
Lender's Name
Lender's Address
0
0 4
I.— z 0 Ut—
cc 'U
a -J
m
Ui z
0
4 U) z 'U
0.
0 C)
Ir
(I)
'U
cc
USE BALL POINT PEN ONLY & PRESS HARD APPLICANT TO FILL IN INFORMATION WITHIN SHADED AREA AND DECLARATIONS.
CARLSBAD BUILDING DEPARTMENT
Carlsbad, California 92008-1989 (619) 438-5525 APPLICATION PERMIT
JOB ADDRESS AU, ST.RD. NEAREST CROSS ST.
714 L.- Q--:t-,
DATE OF APPLICATION DUSINES Lf NSE 41 VALUATION
ZONE
PERMIT NUMBER
S _S1,7 LOT
6,2471
BLOCK 'SUBDIVISION
L,C.14
A SESSOR PA CE NO, FCONTRACTOR CONT ACTORS PHONE
OWNER'S NAME OWNER'SPHONE
RDPhSS $ PLAN t0:
0 4 8 XIR 0 9 _414,
BUILDING SO.
ZTAGE
A OWNER'S MAILING ADDRESS
\_ o
DESIGNER DESIGNERS PHONE
Not Valid Unless Machine Certified -
O E SriO OF BO R
D F I GN ER S ADDRESS LICENSE NO
- '
F/P FLRELEV.
vD NO
NO
STORIES
OCCGP
R:5,--j
I EDU
\
CENSUS TRACT
-
G LAO USE
-
PARKING SPACE
(r) (.,
RES UNITS GRADING PERMIT ISSUED
5 0 N 0
REDEVELOPMENT
AREA
Y LI N
TYPE
CONST
\7 %J
0CC LOAO FIRE SPR
Y 0 ND
QTY. PLUMBING PERMIT - ISSUE QTY. MECHANICAL PERMIT - ISSUE SUMMARY/ACCOUNTUMBER
EACH FIXTURE TRAP(— -D 50 44.__- ......L. INSTALL FURN. DUCTS UP TO 100,000 BTU 4 - BUILDING PERMIT 001-810-0l-O
— (,5 5
EACH BUILDING SEWER ,5 - OVER 100,000 BTU SIGN PERMIT 001-810-0-1
EACH WATER HEATER AND/OR VENT .57 BOILER/COMPRESSOR UP TO 3 HP PLAN CHECK 0Qrj1O-O-6
EACH GAS SYSTEM 1 TO 4 OUTLETS BOILER/COMPRESSOR 3.15 HP TOTAL PLUMBING 0010-03-2 (DiO
EACH GAS SYSTEMS OR MORE - METAL FIREPLACE
- --
- ELECTRICAL oo'TiO-O -3
EACH INSTAL., ALTER, REPAIR WATER PIPE -
-
VENT FAN SINGLE DUCT MECHANICAL I1 O010-0
EACH VACUUM BREAKER MECH EXHAUST - HOOD/DUCTS , MOBILEHOME r4 0O10-04waO825
WATER SOFtr''ER - , - RCATION OF EA FURNACE/HEATER MOBILEHOME PARK INS LaJ 0
EACH ROOF DRAIN (INSIDE - ' L1s..- ca- -
- SOLAR 010-00-6
- TOT L MECHANICAL
7 -
STRONG MOTION 88093 I / TOTAL PLUMBING I - FIRE SPRINKLERS 001-810-00-00-7
QTY. ELECTRICAL PERMIT - ISSUE - QT'L SOLAR - ISSUE PUBLIC FACILITIES FEE 332-810-O0-0O-0
NEW CONST EA AMP/SWTiBKR 77. SZ COLLECTORS - SCHOOL FEE - DISTRICT
1 PH 3 PH , STORAGE TANKS - Carlsbad -
EXIST BLUG,E.AAMPISWT/BKR ROCK STORAGE - Encinitas
1 PH-.. , , \ 3 PH - PUMP San DieguitS
REM OOEL.ALTER PER CIRCUIT - PLAN CHECK FEE - San Marcos
TEMP POLE 200 AMPS -
OVER 200 AMPS' - - LICENSE TAX 001-810-00-00-8162
TEMP OCCUPANCY 130 DAYS) - MFF 880-519-92-57
CREDIT DEPOSIT (&)
TOTAL ELECTRICAL
7-
4 -
TOTAL SOLAR TOTAL FEES PAYABLE
—
I HAVE CAREFULLY EXAMINED THE COMPLETED APPLICATION AND PERMIT AND DO HEREBY Expiration, Every permit issued by the Building Official Under the provisions of this * AN OSHA PERMIT IS REQUIRED FOR EXCAVATIONS OVER C de shall epire CERTIFY UNDER PENALTY OF PERJURY THAT ALL INFORMATION HEREON INCLUDING THE 0 auothorized by such not commenced
limitation and become rti If tIe 50" DEEP AND DEMOLITION OR CONSTRUCTION OF within 180 days from the date of such
DECLARATIONS ARE TRUE AND CORRECT AND I FURTHER CERTIFY AND AGREE IF A PERMIT IS permit, or II the building or work authorized by such permit is suspended or STRUCTURES OVER 3 STORIES IN HEIGHT
ISSUED: TO COMPLY WITH ALL CITY, COUNTY AND STATE LAWS GOVERNING BUILDING CON- abandoned at any time after the work is commenced for a period 01180 days.
STRUCTION, WHETHER SPECIFIED HEREIN OR NOT I ALSO AGREE TO SAVE INDEMNI
KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS COSTS APPLNT'y3NATURE
- 0 RD CONTRACTO A PROVED BY , DATE
EXPENSES-WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF HE BY PHONE It I1/gc
TYPE DATE INSPECTOR
BUILDING
FOUNDATION
REINFORCED STEEL
MASONRY
GUNITE OR GROUT
SUB FRAME LII FLOOR LII CEILING
SHEATHING D ROOF E SHEAR 9/2(/t
FRAME 4ftcL/h7i
EXTERIOR LATH
INSULATION
INTERIOR LATH & DRYWALL _______
PLUMBING
LII SEWER AND BL/CO LII P./CO
UNDERGROUND fl WASTE LI WATER i/i/ic
TOP OUT LI WASTE El WATER
TUB AND SHOWER PAN
GAS TEST
LI WATER HEATER LI SOLAR WATER
ELECTRICAL
LI ELECTRIC UNDERGROUND LIPUFtER
ROUGH ELECTRIC I 4/2.c-/frl
1111 ELECTRIC SERVICE LI TEMPcR/b
U BONDING LI POOL
MECHANICAL
LI DUCT & PLEM., LI REF. PIPING
HEAT - AIR COND. SYSTEMS
VENTILATING SYSTEMS I
CALL FOR FINAL INSPECTiON WHEN ALL APPROPRIATE ITEMS ABOVE HA %(E BEEN APPROVED -
FINAL
PLUMBING
ELECTRICAL
MECHANICAL I
GAS -
BUILDING
SPECIAL CONDITIONS
FIELD INSPECTION RECORD
REQUIRED SPECIAL INSPECTIONS INSPECTORS NOTES
-
. INSPECTION REO IF
CHECKED
INSPECTORS
APPROVAL DATE
SOILS COMPLIANCE
PRIOR TO
FOUNDATION INSP
STRUCTURAL CONCRETE
OVER 2000 PSI -
PRESTRESSED
CONCRETE
POST TENSIONED
CONCRETE
FIELD WEL-DING
HIGH STRENGTH
BOLTS
SPECIAL MASONR .
PILES CAISSONS
FINAL BUILDING INSPECTION
85-517 10-23-86
PLAN CHECK NUMBER: DATE:
S PROJECT NAME:
2747 Llama Ct. ADDRESS:
PROJECT NO.: UNIT NUMBER: PHASE NO.:
SFD 1
TYPE OF UNIT: NUMBER OF UNITS:
Sorkin CONTACTPERSON:___________________________________________________________________________
587-6700
CONTACT TELEPHONE:__________________________________________________________________
all depts
INSPECTED
lre4e,~-44
DATE 4 /2 BY: INSPECTED: APPROVED DISAPPROVED
INSPECTED DATE
BY: ________________________ INSPECTED: APPROVED DISAPPROVED
INSPECTED DATE
BY: ________________________ INSPECTED: APPROVED DISAPPROVED
COMMENTS:
Rev. 1/86 WHITE: Suspense R jig/' CANARY: Utilities PINK: Planning GOLD: Fire
13
FINAL BUILDING INSPECTION
85-517 10-23-86
PLAN CHECK NUMBER: DATE:
PROJECT NAME:
2747 Llama Ct.
ADDRESS:
PROJECT NO.: UNIT NUMBER: _________________ PHASE NO.:
SFD 1
TYPE OF UNIT: _____________________________ NUMBER OF UNITS:
Sorkin
CONTACT PERSON:
587-6700
CONTACT TELEPHONE:_____________________________________________________________________
all depts
____________________ APPROVED _____
INSPECTED /3 C- DATE /
BY: _________________________ INSPECTED: ______ 791SAPPROVED
INSPECTED DATE
________________________ APPROVED ______ DISAPPROVED BY: ________________________ INSPECTED: ______
INSPECTED DATE
BY: ________________________ INSPECTED: ____________ APPROVED ______ DISAPPROVED
Rev. 1/86 WHITE: Suspense GREEN: Engineering CANARY: Utilit1K: Planning LID: Fire
FINAL BUILDING I
5) 7
TE:
35-
Ii
10-23-36
PLAN CHECK NUMBER:
PROJECT NAME: /
7 2747 Llama Ct.
ADDRESS:
-._----- (
PROJECT NO.: \J R: PHASE NO.:
TYPE OF UNIT: NUMBER OF UNITS:
Sorkin CONTACT PERSON:
537-6700
CONTACT TELEPHONE:
all depts
INSPECTED DATE
BY: INSPECTED: APPROVED DISAPPROVED
INSPECTED DATE
BY: INSPECTED: APPROVED ______ DISAPPROVED
INSPECTED DATE
BY: INSPECTED: APPROVED DISAPPROVED
Costa Rea' MunictOal Wptcr flstrct DEC 1 11986 logo. xb~ COMMENTS: Engineering Department
11O
11ev. lThb WHII : Suspense (iHEtN: hngineering CANARY: Utilities PINK: Planning GOLD: Fire
FINAL BUILDING INSPECTION
PLAN CHECK NUMBER:
85-517
DATE:
10-23-86
PROJECT NAME:
ADDRESS:
2747 Llama Ct.
PROJECT NO.: UNIT NUMBER: PHASE NO.: -
SFD 1
TYPE OF UNIT: NUMBER OF UNITS:
Sorkin
CONTACT PERSON:
587-6700
CONTACT TELEPHONE:
all depts
INSPECTED DATE 'A PPROV DISAPPROVED BY: INSPECTED: _________________________ ____ /_ ______
INSPECTED DATE
BY: INSPECTED: APPROVED DISAPPROVED
INSPECTED DATE
BY: ________________________ INSPECTED: ____________ APPROVED ______ DISAPPROVED
COMMENTS:
s're-7
.sr LT5. o7-
Rev 1186 WHITE Suspense GREEN Engine e UesK Planning GOLD Fire
ESGIL CORPORATION
9320 CHESAPEAKE DR.. SUITE 208
SAN DIEGO, CA 92123
(619) 560.1468
*APPLICANT []JURISDICTION []PLAN CHECKER
0 FILE COPY
o UPS
O DESIGNER
DATE: Noume-E. //9i
JURISDICTION:
PLAN CHECK NO:
PROJECT ADDRESS: 21t/' LLI4me4 c.7
PROJECT NAME: ~, f.
The plans transmitted herewith have been corrected where
necessary and substantially comply with the jurisdiction's
building codes.
The plans transmitted herewith will substantially comply
D with the jurisdiction's building codes when minor deficien-
cies identified - are resolved and
checked by building department staff.
The plans transmitted herewith have significant deficiencies
identified on the enclosed check list and should be corrected
and resubmitted for a complete recheck.
The check list transmitted herewith is the jurisdiction's
copy for your information. The plans are being held at
Esgil Corp. until corrected plans are submitted for recheck.
The applicant's copy of the check list is enclosed for the
jurisdiction to return to the applicant contact person.
The applicant's copy of the check list has been sent to:
Esgil staff did not advise the applicant contact person that
plan check has been completed.
Esgil staff did advise applicant that the plan check has
been completed. Person contacted:
Date contacted: Telephone #57199
REMARKS:—
BY: (7&J_te_,) ENCL:
ESGIL CORPORATION
/1-V
U
S
I
ESGIL CORPORATION
9320 CHESAPEAKE DR., SUITE 208
SAN DIEGO, CA 92 123
(619)560-1468
DATE: £7cx5E_c22,/95 []APPLICANT
JURISDICTION
JURISDICTION: []PLAN CHECKER
PLAN CHECK NO: DUPS
[]DESIGNER
PROJECT ADDRESS: '7Y7 LY271 c.T
PROJECT NAME: . ) 0.
The plans transmitted herewith have been corrected where
necessary and substantially comply with the jurisdiction's
building codes.
The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor
identified
deficien-
cies ),&J T.)te are resolved and
checked by building department staff.
The plans transmitted herewith have significant deficiencies
identified on the enclosed check list and should be corrected and resubmitted for a complete recheck.
The check list transmitted herewith is the jurisdiction's
fl copy for your information. The plans are being held at
Esgil Corp. until corrected plans are submitted for recheck.
fl The applicant's copy of the check list is enclosed for the
jurisdiction to return to the applicant contact person.
The applicant's copy of the check list has been sent to:
Esgil staff did not advise the applicant contact person that
plan check has been completed.
Esgil staff did advise applicant that the plan check has
been completed. Person contacted:
Date contacted: Telephone
#___________________
REMARKS:
BY: ENCL:NDR)( D?/t ESGIL CORPORATION -
LJt. io/i & mfrA)L) .A1E7?
4__lJ'' fj
ô r,oJS Fop—
-r E -ro s L4) Pz,(t/,&J
L6N7W 7b iE 7'i9) R cUR// THE
__
Yfl/ SR ___
. PEOUiOE iq E L/7p le- ,C QU7T OJ7+ L.JA-CL 7-me
IpjI MIL_V OOf. ,-LSo 4AJ OLr /5 A) D AJYH iJF--ST
ôP- El2oP j&Jr 77) T/E TV49.
II)OT6 DIJ THE 7j7LE ir T1IE ,2i/cE)r/s -PPUTG.e
• dt-S
rle
'iSi2 /) i-H/s kjc -oP cc'
,J,Jcg.
£.. NorC M PLftt) cL,4.C. , Tc IE i21 0.
,1'JOTE AS ) P?M T Pouz- fP kS
,4S PEFiP EAPERI,
,iMr pyfrpmLs LI&.EV I1O CP/*i., _JoUrfr
___ T7C/ ifr1QttTh ) 1) •ikc A,
ESGIL CORPORATION
9320 CHESAPEAKE DR., SUITE 208
SAN DIEGO, CA 92123
(619) 560-1468
DATE: O.
JURISDICTION:
PLAN CHECK NO:
PROJECT ADDRESS: C, 7J2 LL-y?14
0 APPLICANT
JURISDICTION
PLAN CHECKER []FILE COPY
O UPS
O DESIGNER
PROJECT NAME:
The plans transmitted herewith have been corrected where
necessary and substantially comply with the jurisdiction's
building codes.
The plans transmitted herewith will substantially comply
D with the jurisdiction's building codes when minor deficien-
cies identified - are resolved and
checked by building department staff.
The plans transmitted herewith have significant deficiencies
identified on the enclosed check list and should be corrected
and resubmitted for a complete recheck.
The check list transmitted herewith is the jurisdiction's
copy for your information. The plans are being held at
Esgil Corp. until corrected plans are submitted for recheck.
I'
The applicant's copy of the check list is enclosed for the
jurisdiction to return to the applicant contact person.
The applicant's copy of the check list has been sent to:
am Esgil staff did not advise the applicant contact person that
plan check has been completed.
Esgil staff did advise applicant that the plan check has
been completed. Person contacted:
Date contacted: Telephone #__________________
REMARKS:
BY:. 1JJ,_ ENCL: /thiJOhiL 19T
ESGIL CORPORATION
bJe iUS1 S Ptc&
iac' sros
25-.5/7
o APPLICANT COPY
O CITY COPY
CD PLAN CHECKER COPY
Citp of Carfi5bab
JuRzsorcrroN: 0
PROJECT AODRESS&7L/9 4i.A
TO:
PLAN CORRECTION SRET
SINCLZ FAMILY AND DUPLEX DW!LLIS
Plan Check No.T5i 7
Data plans received by jurisdiction /
Bate plans received by plan checker______________
Data initial plan check ccs.pl.ted.>5)'_JLQ
FOREWORD: PLEASE RE" TeL (619) 560-1462)
Plan check is limited to technical requirements
contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating Sfle9y Conservation, noise attenuation and access for the handicapped. the plan check is based on regulations unforced by the Building Inapiction Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department
or other departments.
The items circled below need clarification,
modification or change. ALL circled items have to be satisfied before the plans will be in
conformance with the cited codes and regulations. Per Sec. 303 (c), 9-Uniform Building Code. the approval of the plans does not permit the violation of any state, county or city law. P1rit)S Lij ID THE
PLANS
Please sake all corrections on the original tracings and submit two new sets of prints,
and any original plan sets that may have been returned to you by the jurisdiction.
to: OEPV.
To facilitate rechecking, please identify, next to each circled item. the sheet of
the plans upon which each correction on this sheet has been made and return this
Check sheet with the revised plane.
Indicate on plans the name of the legal
owner and name of person responsible for
the preparation jt the plans. Sec. 302(b)
Submit fully dimensioned plot plan drawn
to scale showing location sirs, and use of all existing and proposed structures on the lot. Identify property lines and
Show tot dimensions and alt easements. Show location of all cut or fill slopes and approximate finish floor elevations
for all structures and show elevations at
all corners. Sec. 302(b)7.
7'. Indicate distance from center-line of street or alley to property line and distance from
curh to property line. Sec. 302(b)7
Plans, specifications and calculations shalt be signed by a California State licensed engineer as architect. (California
Business and Professions Code)
0. F!RR PRO1CCTIO
Walls closer than 3 feet to property lines shall be one-hour fire-rated construction, have no openings, and shall have 30 inch parapets when the building floor area exceeds 1.000 square feet on any floor. (Table 5-A
Sec. 1709(a)
1. Projections, including eaves, may not extend more than 12 inches into the 3 foot setback from the property line. Sec. 1710 and
Sec. 504(b)
14. Projections, including eaves, shall be one-hour fire-resistive construction, heavy
timber or of non-combustible material if
they project into the 3' setback area Zr the property line. Sec. 1710
I' Show location of porm.inentl wj;ed smoke
detector. Sec. 1210 .sE , f(WD.
C. ROOM SIZES, tICRt', vvrrrr.A?IoNs AND CLAZINC
One room must contain a minimum of 150 square feet of superficial floor area. Sac. 1207(b)
¼. Habitable rooms, other than kitchens, shall contain at least 70 square feet of floor
area. Sec. 1207(b)
Window area must be at least 1/10 of the floor area and a minimum of 10 square feet per Sec. 1207(a). Appears to be deficient
in
2/. Openable window area must be 1/20 of the floor ares and a minimum of S square feet. In bathrooms, laundry rooms and similar rooms. Minimum is 1.5 sq.ft. (Sec.1203(a)
34. One-half of all required window area must be openable in
Provide mechanical ventilation capable of providing five air changes per hour in bathrooms, water closet compartments, laundry rooms and similar rooms if required windows are not provided. Sec. l205Iah (T>*C.I#O
No habitable room. other than a kitchen,
shall be less than 7'0' in any dimension. Sec. 1207(C)
Show that ceiling height for habitable
r2s4in,ua of 76. Sec. t37(a)
Show ceiling height for laundry room!,
hallway!, corridors, and bathrooms is a
minimum of 7'0'. Sec. 1207(a)
34. Provide 30' clear-width for water closet
compartments and 24" clearance in front
of water closet. Sec. 1711(b)
No cooking room shall be used for sleeping
purposes, unless complying as an efficiency
living unit. Sec. 1208
h . Specify safety glazing for glazing in hazardous
I locations such as glass doors, glazing
adjacent to such doors and glazing adjacent
to walking surfaces. Sec. 5406
tj Glazing in shower and tub enclosures
(i.ncLud.ng w.ndows) shall e tempered,
laminated or approved plastic.
Sec. 1711 (f)(g)WJWJDDk.)T
3h. Sleeping rooms shall have a window or
exterior door for emergency exit. Sill
height shall not exceed 44 above the floor.
The window must have an openable area of
at least 5.7 square feet with the minimum
openable width 20' and the minimum openable
height 24. Sec. 1204
Eaves and cornices may not project into
a required yard more than 2 inches for each
foot of yard width if required windows
open into the yard. Sec. 1206(d)
4 . A mezzanine is an intermediate floor and
may not have a floor area exceeding 33 1/3
percent of the total floor area in the room
below, and the mezzanine floor must have
a clear height of 7 feet, above and below, and
must have 65% of the long side open to the
room below.
4j. The loft you show does not comply as a
/ mezzanine floor and is, by Building Code
definition, a story____________________________
D. EXITS, STAIRWAYS, AND RAILINGS
Floors above the second story shall have
not less than 2 exits. Sec. 3302(a)
Required exit doorways shall be not less
than 36" in width and not less than 6'-8"
in height, and shall be capable of Opening
at least 90 degrees. Sec. 3303(e)
4,A. Provide 36" high protective railing for
porches, balconies, and open sides of landings.
Maximum opening between railings shall be
less than ?'.i"Sec. 1716
48.' Show how guardrail connection details are
adequate to support 20 pounds per lineal
foot at a right angle to the top rail.
Table 23-9
Provide stairway and landing details.
Sec. 3305(b) & (c)
Maximum rise 8" and minimum run is 9".
Minimum head room is 61 -6.
C. Minimum width is 30".
Mandrails shall satisfy the following:
Provide handrail for stairways over 30"
high when serving a single dwelling.
Title 24, Sec. T25-22(b)
Handrail shall be 30" to 34" above the
nosing of treads. Sec. 3305(j)
Handrail projecting from a well shall
have a space not less than 1 1/2" between
the wall and the handrail.
The hand_grip portion of handrail shall
be not less than 1 1/4' nor more than
2 "-Mn cross-sectional -dimension.
Sac. 3305(j) (see attached(
Every stairway landing shall have a dimension,
measured in the direction of travel, at
least equal to the stairway width.
Sec. 3305(g(
A door may open over a stairway landing
provided the door, in any position, does
not reduce the clear area of the landing,
in the direction of stairway travel, to
less than one-half the required width of
the stairway. Sec. 3305(g)
A door may open inward at the top step of
a stairway provided the top step is not
more than 7 1/2' lower than the floor level.
Sec. 3303(i(2
54 Provide details of winding stairway.
3 ( Minimum tread is 6 inches at any point
and minimum 9 inches at a point 12 inches
from the side of the stairway.
Maximum rise is 9 inches.
Minimum width is 30 inches. Sec. 3305(d)
I (see attached)
js. Provide spiral stairway details:
Minimum run is 7 1/2 inches at a point
from where the tread is the narrowest.
Maximum rise is 9 1/2 inches.
C. Minimum headroom is 6 feet 6 inches.
Sec. 3305(f)
(see attached)
sft . Sprial stairways may not be used for required
exits when the area served is greater than
400 sq. ft. Sec. 3305(f)
/7. Spiral stairways must have a clear walking
space of 26 inches between the column and
handrail. Sec. 3305(f)
Provide t.C.8.O. Reasearch Report and Number
for metal stairway, or submit plans and
calculations and approved fabricator
registered with the Building Department
or note that the stairway fabrication shall
be done under special inspection per the
approved fabrication plans. Sec. 306(a)43
and Sec. 306(f)
4. tri buildings over 2 stories in height, provide
3/4 hour fire-rated assemblies for all
openings in the exterior wall below or within
10 feet horizontally of an exterior stair-
way. An exit balcony with 2 separated
stairways is exempt. Sac. 3305
6h. Exterior stairways shall not project into
the 3 foot setback from the property lines.
Sec. 3305(n)
/3.
l4.
l6.
The walls and soffits of the enclosed zseable
space under interior stairs shall be protected
on the enclosed side as required for one-hour
fire-resistive construction. Sec. 3305(m)
62..Minimum construction specifications shall
be made a part of the approved plans.
(See attached)
B. ROOFING
7 . Specify roof pitch.
Roof pitch is not adequate for roof type
specified. Specify minimum pitch of__________
74. Specify roof material and application.
Specify I.C.3.0. approval number for roof
materials not covered in USC.
7/4. Specify roof slope for drainage or design
to support accumulated water. Sec. 3207(a)
7 . Show roof drains and overflows. Sec. 3207(a)
76 provide skylight details to show compliance
with Sections 3401 and 5207 or provide ECSO
approval number.
7. Provide plastic roof panel details to show
I compliance with Section 5206 or provide
ICBO number.
76. Show attic ventilation. Minimum vent area
is 1/150 of attic area or 1/300 of attica
area if at least 50% of the required vent
is at least 3 feet above ceiling joists.
Sec. 3205(c)
H. MASONRY
Provide fireplace construction details or
note construction to be per attached fireplace
standard drawing. Sec. 3707
'6. Show veneer support and connections comply
with Sec. 3002. 4.5,6, and Sec. 2516(a)
regarding ties and #9 wire in horizontal
joints or note construction to be per attached
sheets 30-1 or 30-2.
Show height and construction details of
all masonry walls. Chapter 24
6. Note that cleanout openings shall be provided
at the bottom of all cells to be grout filled
over 4' in a single pour. Cleanout shall
be sealed before grouting, after inspection.
Sec. 2415
Show floor and roof connections to masonry
walls. Connection shall resist 200 pounds
per lineal foot or the actual design load,
whichever is greater. Sec. 2310
Provide material specifications for mortar,
grout, masonry and reinforcing steel.
/ Sec. 2403
(3. Show how masonry house walls retaining earth
are to be waterproofed. Provide detail.
,4. Note that special inspection of the masonry
will be required for___________________________
C. GARAGE AND CARPORTS
ifb.Caraqe requires one-hour fire protection
on the garage side of walls and ceilings
common to the dwelling. Table 5-B Sec.503(b)
101 All elements supporting floor above garage
to have one-hour fire-resistive protection
on the garage side. Sec. 503. Beams and
posts, not within the wall or ceiling con-
struction, must comply with USC. Table 43-A,
or be minimum 6" dimension beam and minimum
by Dos.
102 Show 1. 3/8' solid core self-closing door
for openings between garage and dwelling.
Sec. 503(d)
Garages are not permitted to open into
a room used for sleeping purposes. Sec. 1104
Openings between carport and residence
require self-closing doors and stationary
windows. Sec. 1214
Show garage framing section, size of header
over garage opening, lateral cross bracing
at plate line and method of bracing garage
.taLi. Chapter 23
NOTI Minimum plywood diaphragm ratio is
112 to 1 or 2'8'. Table 24-1
Doors between dwellings and attached garages
may swing in either direction provided
the difference in floor elevation between
the dwelling and garage does not exceed
7 1/2 inches and provided the door is not
used as the primary means of egress from
the. building.
If the difference in floor elevation exceeds
7 1/2 inches, or if the door is used as
the primary means of egress from the building,
additional steps or landing must be provided
in accordance with stairway requirements,
and the door must not suing over the depressed
level. (see 3303(i)2 and 3305 (g).
Provide 18 raised platforms for any FAtS,
water heater, or any other device which
may generate a flame or spark. LTEY.NlFF%TEE.
Note that continuous fire wall protection
shall be installed behind raised platform(s)
prior to framing platform.
H. FOUNDATION REQUIRB?ENTS
11 Note an plans that'A soils engineer shall
evaluate any unanticipated uncompacted fill
or expansive soil or other soil problems
disclosed during construction'. Sec.306(a)12.
Submit soils classification determination
by a licensed engineer or architect based
on observation, tests, borings, or excavations,
and containing comments on the degree of
expansiveness, compressibility and bearing
value. Sec. 2905
121 Note on the plan the soils classification,
whether or not the soil is expansive, and
note the allowable bearing value. Sec. 2905
122 The foundation plan does not comply with
the soil report recnjwendation for this
projectf75.Th C
EY rfle0e e%PA,04F. S&PtRArE ARIE
LiS Pnm J,11 -f Pr&s.. 'n Y,'(doji G
Provide notes on the foundation plan
the soils report recommendations for foundations.
slab and building pad preparation.
114. Note on the foundation plan that 'Prior
to the Contractor requesting a Building
Department foundation inspection, the
soils engineer shall advise the Building
Official in writing that:
the building pad was prepared in accor-
dance with the soils report:
the utility trenches have been properly
backfilled and compacted, and:
the foundation excavations, formin'
and reinforcement comply with the soils
report and approved plan.'
1/25. Provide spread footings for concentrated
loads designed for 1,000 PS? soil bearing
or per bearing value as determined by
an engineer or architect. Chapter 29
l6. Show height of all foundation walls. Chapter 23
L7. Show height of retained earth on all foundation
walls. Chapter 23
IfD. Show distance of foundation to edge of
cut or fill slopes and show steepness and
heights of cuts and fills. Chapter 29
1/9. Note on plans that wood shall be 6" above
finish grade. Sec. 2417(c) 7,
130 Note on glans that surface water will drain
away from building and show drainage pattern
and Xey elevations. Sec. 2905(f) rrO.€D.
111. Dimension foundation per Table
TABLE NO. 29.A-FOUNDATIONS FOR STUD BEARING
WALLS-MINIMUM REQUIREMENTS
DEPTH OF FOUNDATION WIDTH THICKNESS BELOW NUMBER THICKNESS OF OF OF NATURAL OF FOUNDATION WALL FOOTING FOOTING SURFACE STORIES (Inches) (Inches) (Inches) OF GROUND AND FINISH UNIT GRADE coicacit MASONRY (inches)
1 6 6 12 6
2 8 8 13 7 18
3 10 10 18 8 24
NOTES:
Where unusual conditioni or frost conditions are found, footings and foundations shall be as required in Section 2907 (a).
The ground under the floor may be excavated to the elevation of the top of the looting.
IP 2. Show foundation sills to be pressure treated,
or equal. Sec. 2517(c) 3.
13. Show foundation bolt size and spacing.
Sec. 2907(e)
134 Specify size, ICB0 number and manufacturer
of power driven pins. Show edge and end
distance and spacing. Sec. 306(f)
1/5. Show size, imbedment and Location of hold
down anchors on foundation plan. Sec. 2312(f)
1/36. Note on plan that hold down anchors must
be tied in place prior to foundation inspection.
Sec. 2312(f)
1/37. Show adequate footings under all sheer
walls. Sec. 2311(e)
Show stepped footings for slopes steeper
than 1:10. Sec. 2907(c)
1/39. Show minimum 18" clearance from grade to
bottom of floor joists and minimum 12"
clearance to bottom of girders. Sec. 2517
110. Show pier size, spacing and depth into
undisturbed soil. Table 29-A
141. Show minimum under floor access of 18"x 24".
Sec. 2517
112. Show minimum under floor ventilation equal
to 1 1/2 sq. ft. for each 25 lineal feet
of exterior foundation with openings as
close to corners as practicable to provide
cross ventilation on at least two approximate-
ly opposite sides. Sec. 2517
I. FRAMING
lfo. Show all joists, rafters, beams, and posts
2" to 4 thick to be No. 2 Grade Douglas
Fir-Larch or better. All posts and beams
5" and thicker shall be No. I Grade Douglas
Fir-Larch or better. (Table 25-A-I)
I/I. Show wall bracing. Every exterior wood
Stud wall and main cross partition shall
be braced at each end and at least every
25 feet of length with 1x4 diagonal
let-in brace or equivalent. Sec. 218(g)S
1%'2. Note cross bridging or blocking. Floor
joists and rafters more than 12" in depth
and spanning more than 8 feet shall be
supported laterally by bridging at intervals
not exceeding 8 feet. Sec. 2506(g)
113. Show blocking at ends and at supports / of floor joists, and for rafters at exterior
walls. Sec. 2506(g)
l4. Show solid blocking at ridge line and
at exterior walls on trussed roofs.
Sec. 2506(g)
us. Show double joists. Floor joists shall
I be doubled under bearing partitions running
parallel with the joists. Sec. 2518(d) 5
1/66. Show rafter ties. Rafter ties shall be
spaced not more than 4 feet on center where rafters and ceiling joists are not
parallel. Sec. 2518(h)
167. Show rafter purlin braces to be not less
than 45 degrees to the horizontal.
Sec. 2518(h) 5rrlci4eo,
Show 1/2" minimum clearance between top
plate of interior partitions and bottom
chord of trusses. (To ensure loading
will be as designed.)
Show double top plate with minimum 48"
lap splice. Sec. 2518(g)4
1/0. Show nailing will be in compliance with
Table 25-P.
1. Provide fire stops between stories, between
top story and roof space, at ceilings
and floor levels in interior and exterior
walls, in mansard roof or eyebrow so no
concealed or furred space is greater than
10 horizontally or vertically, between
stair stringers at top and bottom and
between studs along and in line with
stair run adjoining stud walls and partitions,
at perimeter of sliding door pockets,
between chimney and wood frame using metal
or incombustibles for the fire stop and
at other places that could afford passage
of flame. Sec. 2517(f)
112. Show stud size and spacing. Maximum allow-
able stud heights: 2"x4"9 16" is 14';
3"x4"&2x6"9 16'o.c. is 20'. Sec. 2518(g)2
173 Note an A.I.T.C. Certificate of Compliance
Ear glued laminated wood members shall
be given to the Building Inspector prior
to erection. Sec. 306(f)
l4. Detail all post to beam and post to footing
connections. Sec. 2517(c) 4
1/5. Specify nail size and spacing for all
shear walls, floor and roof diaphragms.
Indicate required blocking. Maintain
maximum diaphragm dimension ratios.
(Tables l,J,K).
1h6. Show 3"x4" or 2"x6" studs in first story
of three story building. Sec. 2518(f)
117. Provide truss details and truss calculations.
1 8. Provide roof framing plan. Sec. 302(a)7
179 Provide framing sections through: .SE.-rso.J-
p\jp /)
Section 302(a) 7 frrc-.
Specify all header sizes for opening over
4' wide. Sec. 2518(g) 7
ltl. Provide calculations for_____________________
Section 302(a) 7
l2. In areas subject to water splash and in
exterior locations, wood columns and posts
shall be supported by piers projecting
at least 2" above the finished grade and
shall bear on a metal base plate or treated
wood unless the columns or posts are foun-
dation grade redwood or cedar. Sec. 2517(c)4
18/3. Show location of attic access with minimun
size 22" x 30". Sec. 3205
Show draft separation for attic areas
in eXCeSS of 3.000 sq.ft. Sec. 3205
Show draft Scoaration. for space between
dropped ceilings and floor above in excess
of 1.000 sq.ft. Sec. 2517
Specify plywood grade and panel indenti-
fication index. Table 25-J
117. When roof pitch is less than 3:12, design
ridge as a seam. Sec. 2518 (h)
Wood shear walls shall not be used to
resist horizontal forces contributed by
masonry in buildings over one story in
height. Sec. 2516(b)
Gypsum lath and plaster, gypsum sheathing
board and gypsum wallboard shall not be
used in vertical diaphragms to resist
forces imposed by masonry or concrete
construction. Table 47-1
1910. If cripple wall studs are less than 14',
framing shall be solid blocking. Sec.2518(9)6
11. Cripple wall studs exceeding 4 feet in
height shall be 3 inch by 4 inch or 2
inches by 6 inches when supporting 2 stories.
Sec. 2518(g)6
l2. Show plywood sheathing over exposed eaves, I or other weather exposed areas, is exterior
grade. Sec. 2517(g) 3
Show a weep screed at the foundation plate I line on all exterior stud walls to be
stuccoed. Sec. 4706(e)
Provide an approved waterproof building
paper under wood siding. Sec. 1701(a)
Specify an approved flashing for exterior
openings and parapet walls. Sec. 3208
Show corridor width to be minimum 36'.
Sec. 3304(b)
Specify truss layout for 30" x 30" attic
access.
Ridges, hips, and valleys shall be at
least one size larger than supported
rafters. Sec. 2518(h) 3
1/99. Provide metal straps across ridge beam and rafters.
J. MECHANICAL
All heating, ventilating, and cooling systems
and appliances shall comply with the Uniform
M chanical Code.
200 Show the size_ location andtype of all
heating and cooling appliances or 5y5tam5.
2l. Show source of combustion air for furnace
will comply with Chaper 6, U.M.C.
22. Every dwelling unit shall be provided with
heating facilities capable of maintain-
ing a room temperature of 70° F. at 3
feet above the floor in all habitable
rooms. Show basis for compliance. (JBC
Sec. 1211
J03. Show minimum 30" deep unobstructed working
space in front of furnace.
Note on plans,clearances to be per manufac-
turers listing. Sec. 704 JMC
Furnace shall not be installed under any
stairway. Sec. 704 (iNC
Furnace shall not be installed in any
bedroom, bathroom, closet, or in confined
space with access only through such room,
unless specified as direct vent appliance,
enclosed furnace or electric heating appliance
Sec. 704 (iNC
2/7. Show ICSO approval for prefab fireplace
and provide approved installation instructions
at job site.
28. Show access to the attic or under floor
furnace to be minimum 30 inches by 30
inches. Sec. 708 i 709 (iNC
2p9. Note that passageway to the attic furnace I shall be unobstructed and have continuous
solid flooring not Less than 24 inches
wide. Sec 708 (iNC
2/1 0. Show permanent electrical outlet and
lighting fi.'ctura controlled by a switch
for the attic furnace. Sec. 708 (INC
21. Show details to comply with Section 709
- for furnace under the floor, Section 708
for attic furnace, or Section 710 for
roof or outside furnace.
2/12. Note on plan, gas vents and non-combustible
piping passing through three floors or
less shall be effectively draft stopped
at each floor or ceiling. ),IBC Sec. 1706(a)6
K. ELECTRICAL (National Electrical Code)
All wiring shall comply with the National Electrical
5e.
221 Note on the plan the amperage of electrical
service.
22. If the electrical installation is more
than 200 amperes, show panel location
and provide a single line diagram and
load calculations including:
Wiring method employed.
Sizes of all conductors, switches,
circuit breakers, fuses, and conduits.
C. Approximate length of service feeders.
Provide plot plan showing services,
all panel locations, circuit arrangement
and load distribution on panel busses.
Provide typical panel schedule(s).
223 Dwellings require minimum 100 amp service.
Show location of all electrical receptacles.
225. Electrical receptacle locations and/or
spacing is not adequate in JOA)L1f. keom,
JJuIAX'R-)I
1
F
Al At least one receptacle shall be
outdoors, in basements and attached garages,
other than laundry outlets. Art. 210-25(b)
227 Show minimum dwelling lighting (NEC
0 Art. 210-26(a) and GEM'S in 0ar50e, baths and outdoors. NEC Art. 210-8(a),
228 Note "UFER" ground to be provided (NEC).
Art. 250-81
L. PLUMBING (Uniform Plumbing Code)
All plumbing shall comply with the (Jnifrom
Plumbing Code.
26. Show water heater size, type and
location on plans.
247. Show method of providing combustion air
to fuel burning water heater. Sec. 1307
2/38. Fuel combustion water heater shall not be
installed in bath or bedroom or in a closet
opening into bath or bedroom. Sec. 1309
39. Provide adequate barrier to protect water
heater from vehicle damage. Sec. 13'lO
240 Show T and P valve on water heater and
show route of discharge line to exterior
Sec. 1007(e)
242 Provide dryer vent to outside. (INC
Sec. 1903
2/3. Note on the plan that hose bibbs and lawn
sprinkler systems shall have approved
backflow prevention devices. Sec. 1003
3/44. Shower stall shall accomodato a
and have a minimum floor area of 900 sq.in. (iPC 909(d)
MOCSE :NSUE.X?tCN (OUPtZXE$
show lst3l.113 of duplex onmicn 'Party,w3tls
and oor. .iLircz 4ssumciLds to cntve
Sound rn.jnI.s1LOI1 .:ss T) racing
in 44111 Ot 1(1 dectulos and an 1nIpaCt
Cnoul%tiott CIASS Ci.l ricing on elour.
ceiling of ia 2ecits.. Title 23
Show now p.net3t.0n of 4aseacLies for
piping. electrical, devices. recessed
5antuSs. soffits. or heating
or e*flau5C ducts shaLl be seated. Lined.
or insulated to maintain required sound
trsnsaiaston racing. Title 25
2. Provide insulation in wL1i and ceiiinq
to aenieve SIC of 30 between garage and
Living area if garage use ix not controlled
by resident TItle 25.
U. IERC'f COIlSERVATTONt Pleas. Read
New State Mandated Regulations
(Calif. Adman. Cod.) became effective June 16, 1983 and require that the design satisfy one of the alternative energy packages (see attached package. A. 8, C. 1, 2, 3, 4 and AS 163). The law also requires that many mandatory cons.rvation items be sat4fi.d.
is in Zone 7 Copies of the Residential Energy
Conservation Manual may be obtained from: Publications Unit, California
Energy Commission. 1111 Mow. Ave. ?-50. Sacramento, California 95825. (Tel. (916) 920-6216)). California Building
Officials also maintain a telephone
hotline between 10:00 A.M. and Noon and 1:00 P.M. to 4:00 P.M. at (916) 456-3823.
272 Show on the title sheet of the plans. the alternative energy package that was selected i.e. A. B, C. 1, 2. 3. 4, or AS 163 to show compliance, and provide calculations and other data.
appropriate to
24. The responsible designer should sign a statement, on the plan title sheet. The design submitted substantially conforms to the Energy Regulations for Residential Buildings..
274 Show the •R value for the walls and ceiling and related areas.
27 Note that the insulation used shall
comply with California Quality Standards.
27 Note the insulation installer shall pest a signed certificate, in a conspicious
place in the building. stating the insulation complies with Title 24, Chapter
2-53 and Title 20, Chapter 2. Subchapter 4, Article 3.
27/7. Note doors and windows, including skylights. between conditioned and non-conditioned space shall be fully weatherstripped.
2/I8. Note on the framing plan that weather-stripping, caulking or sealants must be used to limit filtration in the building envelope at the following location.: Exterior joints around windows and door
frames; between wall sole plates and floors, and u..twwen exterior waii paneis; penetrations in walls, ceilings, and
floors for plumbing, electricity, and gas lines: openings in attic floors;
and 311 other openings in the building envelopu.
27(9. Note that doors and windows to be certified
and laeeled as complying with the Energy Regulations.
j0. Note fans exhausting air to have back f
draft dampers.
21. Not, at the exterior wall fireplace I Pir.plac. to have minimum six square inches of outside air: to have glass or metal door covering the entire opening
of the firebox; to have tight-fitting damper with readily accessible control and should not have a continuous burning
pilot light'.
82. Note ducts shall comply with Chapter 10.
1976 (INC and shall be tightly sealed with mastic or tape.
Note at the water heater location'voter
heater to have wrap of R-12 external
insulation.
Note, where water heater is in unconditioned I space, the first five feet of outlet pipe to have R-3 wrap.
245. Note all circulating hot water pipes I in unconditioned spaces shall be insulated. 2p6. Note that all gas fired heating and I cooling appliances, showers and faucets shall comply with the Energy Efficiency Standards.
7. Show, at bath and kitchen, that the general lighting shall have an efficiency
of not less than 25 lumens per watt i.e. florescent.
S. Note that heating or cooling systems I (except fleet pumps) shall have an automatic thermostat with mechanism which can be
manually programmed to automatically
set back the thermostat set points for at least two periods within 24 hours.
28 . Show the size, type and location of
the space heating (or cooling) system
S
and provide energy calculations if the output BTU/Hr. exceeds 45,000 33(2/Mr. output.
290 Show make and modal for PASi and mat.X beater are on State approved list.
2L. Outdoor poets eitn fossil fuel heaters I require pool covers as well as ocfler energy saving devices sucn as time clocks. etc. .20-L406
2.:. MI5CLLANZOUS
Show a minimum 2 air space and flashing I between planter and building walls.
Sec. 2517(e)
Specify material to be used under the
shower tile. Sec. 1707(a)
313. Specify lath and plaster to comply with
Chapter 47, USC,
304 Two 3/4 copper pipes must be installed
from water heater location to convenient
Location of future solar panels (City Ord.)
305 Provide sleeves (roof jacks) in roof for
two future 3/4 copper pipes to cunvertient
location of future solar panels (City Ord.)
06 Note that solar water aiping is to be insulated
in areas that are not heated or cooled. (City Ord.)
0 Building plans are substantially correct and complete.
By:
Date:
Building plans would be substantially correct and complete is minor corrections are made
at counter.
By:_
Date:
Building plans require mayor corrections and complete plan recheck, by plan check engineer, is required.
By: E)LE,cj LAJI5t..ke.
Date:
If you have any question, regarding
this plan check, please callcILEEAI_liJM..kE,2.
at
We would also be pleased to meet with you, at no charge, if additional assistance is needed.
I3 L.dHEJ Roonis usr /( LC4Tb iJ ArAJ
&±PJEL, A Smrm Cii. JAV )7fr1-' LOCA 2)
fl-fe jli D,RFCTL'1 AA AIJE ri gi9. ___
3. PiOu o ro L n u A mv rzôpi ,WJA!e,vT 70 6eplapnp7 &3
Pñ-) 7Z T/ L/'VO T THE
3. 7/4-E ,000k g-rAPIP. AA 13 1T LI,41jE -t1;,yfpn4l 4'2e/../ij
h '#7.
(C..o&-r) TIc'iEs pp 60AASTie ucTJO& T O. LJ1VftzN1 TEAJD THE
DT f 7 PoAJ T1AJ b
IO PRo ooE eosrn)E hiJC'E AtJkV 1HE UiiJ w,77t,1 T/C/I
i- iST 5 /A) J4O A I 10,92TA-(.- O1$Tk1vC.E OF
JLL€2 PLE.4SE cLP'RU' Tfrt PURL IJ wrfr* xV k/CE. thZfrC-E ,4eP4Q.s To 6
Jo? IA) IErn7-?t,E F!AJC tF5€C 2 577(h): 57-1ZU7 fliLST WoTX(ff
8" /A) LAJe,T,- 'A,ULi53 /7 15 2,4€.1FY ML 151-L4T
L%) Powo urTI,qr/,jJ YH,T £,2JA)G. StPPfT ',•je
Aire APP.A 7frikT /)A 014L 7) 1POT A,E ,4JO
.4) L oi WITH &,4,2,A)d, FOoyij 65
DInIIAJSI 3 &c op /tE 0O7/AJ.s SI U)JO/ frQ,V
)4)WA) OAJ rAi/âL)
Tfl Xfr7,J 41
frI1XtJk) ."AJ C. S1T /t /JT AC?L
TH £i Y jA YYI S P 0, wt) ')A)6 ic :5'
7'Atj') tfro.
1'L/Lky f'FeoV1 A)OPiAJ?A)C, Tb / &Pr,Le llrvp m4yvuv
tS' jeyEEO o 'rL.rs.
c2L Pcu,oc EA)e.v C',4L.c!.. !0k- 77-,s Si)JCf QR
ti 1i 4 IJE. Or- -T,~4r, ATTAcf P,/A-c.es.
F4W4 OR '-,IA) ,stoi OAJ sr. . ,i'jr 'u -u'io PtaivliE,
A)0r n) T/1 TITLE SMeer 77l)r mes4 PLA/J S )wi.4' L'Jl7-, 7hE
fiRUç I99i#, i97Oi- ft'JO I/,UEc
Q CITY OF CARLSBAD
Table 7. Alternative Component Packages, Climate Zone 7
C
Building Measure
Package Designation
--- - - L L 1 L J
INSULATION R-VALUE MINIMUM
Ceiling 19 30 19 30 30 30 19 30 19 30 19
Wall 11 11 11 11 11 11 11 11 11 11 11
heavy" Wall 2.5 2.5 2.5 NA NA 2.5 2.5 2.5 2.5 2.5 2.5
"Light Mass" Wall 4.0 3.5 3.5 NA NA NA NA NA NA NA NA
Slab Floor Perimeter NR 7 NR NB. NA NR NB. MR NR 7 NR
Raised Floor 11 11 11 NA 19 NR NR 19 19 11 11
rric3 NB. NB. MR REQ REQ REQ NB. REQ MR NB. NB.
GLAZING
Maximum U-Value 1.1 .65 1.1 .65 .65 .65 1.1 .65 1.1 .65 .65
Maximum Total Area % NB. 14 14 20 20 20 24 20 24 MR NR
Maximum Total Nonsouth
Area /Z 9.6 NA NA NA NA MR NB. NB. NB. 8.4 9.6
Minimum Total South
Area % 6.4 MR MR NB. NR NR MR MR NB. 5.6 6.4
SHADING COEFFICIENT
South-facing Glazing MR NB. NB. MR NB. NB. NB. MR NB. NB. MR
West-facing Glazing MR MR MR .36 .36 MR MR NB. NB. NB. NB.
North-facing Glazing NB. MR NB. NB. NB. MR NB. MR MR NB. NB.
East-facing Glazing NB. MR NB. MR MR MR MR NB. NB. NB. NB.
LHERMAL MASS EQUIVALENT
.X Slab Floor Exposed8 50 MR MR 25 5 25 25 20 15 NB. 50
:NFILTRATI0N CONTROL
Continuous Barrier NR MR MR MR NB. NB. MR NB. MR NB. NB.
lectrjcal Outlet Plate NR NR MR NB. NB. NB. MR NB. NB. NR NB.
Caskets
Lir-To-Air Heat Exchanger NB. MR NB. NB. NB. MR NB. NB. MR NB. NB.
PACE HEATING SYSTEM
Gas Furnace Seasonal
Efficiency Z MIN MIN HIM HIM HIM HIM HIM HIM HIM
Heat Pump ACOP 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5
Electric Resistance" NO NO NO NO NO NO NO NO NO YES YES
PACE COOLING SYSTEM
A/C or Heat Pump SEER
ATER HEATING SYSTEM
Gas, Heat Pump or Solar
with Any Backup REQ REQ REQ REQ REQ REQ REQ REQ
Solar with Gas Backup I REQ REQ REQ
Appendix B
3-9
C-70 ACP
.••••
Table 17. Notes for Tables 1 through 16, Page 1 of 4
LEGEND: NR Not required, N/A - Not applicable, REQ - Required,
MIN - Minimum efficiencies required by Section 2-5306 of the
regulation. NO - Heating system type not allowed, YES Heating
system type allowed.
3. Whenever an attic is required, it must cover at least three-quarters
(3/4) of the ceiling area over conditioned space and be vented.
In alternative component packages which require thermal mass (other than
Package A), the specified percentage of mass must be directly exposed to
the conditioned space. To determine the floor area directly exposed to
the conditioned space. To determine the floor area, count only the first
floor in conditioned areas. Uncarpeted first floor areas, such as
linoleum or tiled entry ways, kitchens, bathrooms, and utility closets
may all be counted towards this requirement.
Thermal mass required for Packages E,1,2,3 and 4 must be either
equivalent to a slab floor covering one-fourth (25 percent) of the floor
area with a thickness of at least 2 inches and a volumetric heat capacity
of 28 Etu/ft3 °F (see below for surface area of materials examples) or
provide the minimum total mass capacity listed in Table 17 of Appendix A
(use the Point System to calculate the mass for other materials).
Climate Slab
4' brick
exposed
Concrete block 90pcf
block density,
Concrete block 140 pcf
block density, solid
Zone Floor Z one side grouted grouted
411 611 40. 6"
15 21 18 17 14 13
20 28 24 22 18 18
7 25 35 30 28 23 22
11. For Packages 5 and 6 electric resistance and radiant heating systems
shall have two or more separately controlled zones in each dwelling
unit.
D ate z 9-o?5' Jurisdiction dfigL6,6 ,ai9
Prepared by
£ W,4LIV- VALUATION AND PLAN CHECK FEE
Bldg. Dept.
Esgil
PLAN CHECK No._g5---57'7
BUILDING ADDRESS 'J 47 LL,4ym4 r
APPLICANT/CONTACT ; PHONE NO. 5ê1-1 -06 Z5-
BUILDING OCCUPANCY DESIGNER PHONE
TYPE OF CONSTRUCTION V-hi CONTRACTOR PHONE V8/-T,',
BUILDING PORTION BUILDING AREA VALUATION
MULTIPLIER
VALUE
- -
Air Conditioninz
Commercial
- Residential
Res. or Comm.
-Fire Sprinklers
Total Value
Fee Adjusted To Reflect DEnergy Regulations (Fee x 1.1)
0 Handicapped Regulations (Fee x 1.065)
Building Permit Fee $
Plan Check Fee $ $
COMMENTS:
8/4/82
PLAN CHECK t4uMBER-Si) ADDRESS X)17 2J#wii4 Q.IF DM _21
PLANNING: TYPE OF STRUCTURE c ZONE: -
SCHOOL FEES: SAN DIEGUITO ENCINITAS_____________________
NUMBER OF UNITS CARLSBAD SAN MARCOS____________________
REQUIRED SETBACKS
BUILDING HEIGHT / FRONT_______________________
FENCES/WALLS SIDE 0
TWO CAR GARAGE REAR________________________ LiJ
LW CC1ENTS:____________________________________________________________________
vi
REDEVELOPMENT AOVAL REQUIRED:__________________________________________________
'I I W L.J
' ' LANDSCAPE PLAN CO?iENTS:______________________________________________________
EnvInc?:;ENTAL REQUIRED:
ADDITIONAL COMETS:
OK TO ISSUE: DATE: OK TO FINAL: DATE:_________
ENGINEEtING LEGAL DESCRIPTION VERIFIED? V' A.P.N. CHECKED?±
15
PARK IN LIEU _JN __________________________________
_
_
R.O.W:$\A IMPROVEMENTS:
E.D.U: LCiio oiZ
SEWER: LC
LATERAL: J461-0 ni;:
,
DRIVEWAY:e h,'1 icw5
GRADING PERMIT:
ORAINAGE: ç)
EASEMENTS: 10 ) MOD I T I ONAL COMMENTS:. 9159; AEA ft7-7~1
OK TO ISSUE: DATE: 1/0 20
* ENGINEERING INSPECTION REQUIRED:______________________________________________
PUBLIC WORKS INSPECTOR:_______________________________________________________
FINAL OK: DATE:
* IF THIS ITEM IS NOT CHECKED, BUILDING DEPARTMENT WILL MAKE ALL INSPECTIONS
(DRIVEWAYS, CURB CUT, DRAINAGE, ETC.)
"a
110G. NO.
SAN MAR(D9 UNIFIED SCHWL DISTRICT
PROJECT SERVICE AVAILABILITY LETTER
APPLICANT:
Address:
Phone No. -
'\7c?
Phone Nd____________
Address:_______________________________
QJECr DESCRIPTION Project Address/thcat ion fl CTS
olect Name:
oject located on
Assessors Parcel No.(s):
Attach legal description
if necessary)
Tract No.
(check one or more)
[Ii Minor Subdivision (TPM)
17 Major Subdivision (TM)
Assessor's Parcel Numbers
3.
=1A I AiIiiii 4.1 ===
Housing Type No. of D.U. 's No. of Bedrooms
Single Family I
tiple Fami
Mobilehcme Units
Owner/applicant agrees to reconfirm this project with the issuing school district every 6 months
unless such action is not required by the district. District Phone619-744-4776
Owner/applicant understand that the certification for school service contained in this Project
Service Availability Letter is no longer effective if the project is disapproved or if the con-
ditional project approval (subd ision, nermit, or other conditional use processes) expires.
The information I have prov r ec
.
APPLICANT's SIGNATURE i Date
SAN (X UN I L DISTRICT
CERTIFICATION OF SCHOOL AVAILABILITY OR NON-AVAILABILITY
Date: MD (I III DAY [I YR Ib!51
City of Carlsbad
FROM: School District San Marcos Unified Grades Served: K-12
School services and facilities are committed for this project. Services will be available
concurrent with project need based on a secured agreement with the developer which has
adequate financing and clear intent. The termination date of the document is:
See attached copy.
The undersigned school district hereby certifies that it will be able to provide adequate
school services and facilities to the above described project concurrently with the need of
such project. Owner/applicant has paid the required developers fee.
The undersigned school district hereby certifies that it will not be able to provide adequate
school services and facilities to the above described project concurrently with the need of
such project because
DISTRICT REPRESENTATIVFIS SIGNATURE (21ACAtV11" ___ Date 11/18/85
TITLE Facilities Planning Phone 7444776
WHITE-CIVIC ENTITY YELLOW-DISTRICT PINK-OWNER/APPLICANT
San Marcos Unified Schoot District.
270 San Marcos Blvd, San Marcos, California 92069-2797 619-744-4776
November 18, 1985
MFMflRANflIIM flF A(PFFMFNT
REFERENCE: 215-420-13
2747 Llama Ct
We, the owner or agent for the owner of the above-reference property,
hereby agree to pay$2,758.00 as a fee-which will satisfy the
requirements for school facilities dedication- of land and fees. In
exchange for this fee, the District will execute the availability form
for the above-reference property.
Sun State Homes $2,758.00
NAME AMOUNT RECEtVED
12760 High Bluff Dr, Ste 370 5/j,
STREET By IV
San Diego, CA 92130 November 18, 1985
CITY DATE
TELEPHONE
LEUCADIA COUNTY WATER DISTRICT
APPLICATION FOR SEWER SERVICE
Owner's Name Mr & Mrs Mike Grubic
Mailing Address 2645 Abedu
Carlsbad, Calif 92008
Service Address: Llama Ct
Tract Description: -lot 627 La Costa Meadows #4
Assessor's Parcel No. 215-420-13
Phone No.
Type of Building s.f. No. Units 1 Connection Fee $600.00
Lateral Size: 4" 6" - 8" Saddle - Easement Connection pre-pd 200.00
Extra Footage: @ $________ Extra Depth: @ $
Lateral Fee
Amount Rec'd $.tVDO.0 Prorated Sewer Ck. No/Cash Service Fee Date ____
Rec'd By Total $tCxcC
The application must be signed by the owner (or his authorized representative) of
the property to be served. The total charges must be paid to the District at the
time the application is submitted.
If a service lateral is required, it will be installed by the Leucadia County Water
District. The service lateral is that part of the sewer system that extends from
the main collection line in the street (or easement) to the point in the street (at
or near the applicant's property line) where the service lateral is connected to
the applicant's building sewer. The applicant is responsible for the construction,
at the applicant's expense, of the sewer pipeline (building sewer) from the appli-
cant's plumbing to the point in the street (or easement) where a connection is made
to the service lateral.
The connection of the applicant's building sewer to the service lateral shall be
made by the applicant at his expense. The connection must be made in conformity
with the District's specifications, rules and regulations; and IT MUST BE INSPECTED
AND APPROVED BY THE DISTRICT BEFORE THE SEWER SYSTEM MAY BE USED BY THE APPLICANT.
THE APPLICANT, OR HIS AUTHORIZED REPRESENTATIVE, MUST NOTIFY THE DISTRICT AT THE
TIME INSPECTION IS DESIRED. ANY CONNECTION MADE TO THE SERVICE LATERAL OR COLLEC-
TION LINE WITHOUT PRIOR APPROVAL AND INSPECTION BY THE DISTRICT WILL BE CONSIDERED
INVALID AND WILL NOT BE ACKNOWLEDGED.
The prorated sewer service fee is based upon the date the District estimates that
service will begin and covers the balance of the fiscal year. There will be no
additional fee or refund if service actually commences on a different date. For
succeeding fiscal years, the sewer service fee will be collected on the tax roll
in the same manner as property taxes.
The undersigned hereby agrees that the above information given is correct and agrees
to the conditions as stated.
V
o; '
Owner S ,nature Date Account No.