Loading...
HomeMy WebLinkAbout2751 ASCOT AVE; ; CB062072; Permit07-19-2006 City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Patio/Deck Permit Permit No:CB062072 Building Inspection Request Line (760) 602-2725 Job Address: Permit Type: Parcel No: Valuation: Reference #: Project Title: 2751 ASCOT AV CBAD PATIO 2131811400 Lot#: 0 $1,080.00 Construction Type: NEW CHONG RES-120 SF PATIO COVER Applicant: CHONG FAMILY TRUST 05-11-05 2751 ASCOT AVE CARLSBAD CA 92009 Status: ISSUED Applied: 07/19/2006 Entered By: RMA Plan Approved: 07/19/2006 Issued: 07/19/2006 Inspect Area: Plan Check*: Owner: CHONG FAMILY TRUST 05-11-05 2751 ASCOT AVE CARLSBAD CA 92009 Building Permit Add'l Building Permit Fee Plan Check Add'l Plan Check Fee Strong Motion Fee Renewal Fee Add'l Renewal Fee Other Building Fee Additional Fees TOTAL PERMIT FEES $23.01 $0.00 $14.96 $0.00 $1.00 $0.00 $0.00 $0.00 $0.00 $38.97 Total Fees:$38.97 Total Payments To Date:$38.97 Balance Due:$0.00 Inspector: FINAL APPROVAL Date: fa Clearance: NOTICE: Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030, Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which you have-previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired. PERMIT APPLICATION CITY OF CARLSBAD BUILDING DEPARTMENT 1635 Faraday Ave., Carlsbad, CA 92008 FOR OFFICE USE ONL PLAN CHECK NO. EST. VAL.. ; Plan Ck. Deposit Validated Bv 4.7r/ ft*e+Jc.Ai/ Address (include BIdg/Suite *)Business Name (at this address) Legal Description Lot No.Subdivision Name/Number Unit No.Phase No.Total # of units Assessor's Parcel #Existing Use Proposed Use (Sec. 7031.6 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to Its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law (Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code] or that he is exempt therefrom, and tha basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars 1*60011. Name State License # Address License Class City State/Zip City Business License # Telephone * Designer Name State License # Address City State/Zip Telephone Workers' Compensation Declaration: I hereby affirm under penalty of perjury one of the following declarations: Q I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. n I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My worker's compensation insurance carrier and policy number are: Insurance Company Policy No. Expiration Date (THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS 1*100} OR L£SS> G CERTIFICATE OF EXEMPTION: I certify that in the performance of the work for which this permit is issued, I shall not employ «ny person in any manner so as to become subject to the Workers' Compensation Laws of California. WARNING: Failure to secure workers' compensation coverage Is unlawful, end shaft subject an employer to criminal penalties and dvN fines up to one hundred thousand dollars ($100,000), In addition to the cost of compensation, damages as provided for in Section 3706 of tha Labor code, interest and attorney's fees. .SIGNATURE DATE I hereby affirm that I am exempt from the Contractor's License Law for tha following reason: P. I, as owner of the property or my employees with wages as their sole compensation, will do tha work and tha structure Es not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not Intended or offered for sale. If, however, the building or improvement ia sold within one year of completion, tha owner-builder will have the burden of proving that he did not build or improve for the purpose of sale), Q I, aa owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractors) licensed pursuant to the Contractor's License Law). I am exempt under Section Business and Professions Code for this reason: I pwaonmlly plan to provide the major labor and materials for construction of the proposed property improvement. W YES QNO I tiave/nave not) signed an application for a building permit for the proposed work. I hivf contracted with the following person (firm) to provide the proposed construction (include name / address / phone number / contractors license number): 4. I plan to provide pontons of the work, but I twve hired the following person to cooidinata, supervise and provide the major work (Include name I address / phone number / contractors license number): __ 5. I will provide aome of the work, but I have contracted (hired) the following persons to provide the work Indicated {Include name / jddressj phone number / type of work): . _. „ . /*/• PROPERTY OWNER SIGNATURE Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management end prevention program under Sections 25506, 25533 or 25634 of the Presley-Tanner Hazardous Substance Account Act? D YES Q NO Is tha applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? D YES D NO Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? Q YES Q NO IF ANY OF THE ANSWERS ARE YES. A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. I hereby affirm that there is a construction fending agency for the performance of tha work lot which this permit is issued {Sec. 3097W Civil Code). LENDER'S NAME LENDER'S ADDRESS I certify that 1 have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all City ordinances and State laws relating to building construction. I hereby authorize representatives of the City of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: An OSHA permit is required for excavations over 5'0" deep and demolition or construction of structures over 3 stories in height. EXPIRATION: Every permit issued by the building Official under the provisions of this Code shall expire by limitation and become nu« and void «the bulldino or work authorized by such permit is not commenced within 100 days from the date of such permit or if the building or work authorized by such permit is suspended or abandoned *s£t any time after the work is commenced for a oeriod of 180 daysrfSectipr/l 06.4.4 Uniform Building Code). •* APPLICANT'S SIGNATURE $-*7M**^~V ^L^V^^ DAJE City of Carlsbad Bldg Inspection Request For: 10/11/2006 Permit* CB062072 Title: CHONG RES-120SF FREE STANDING Description: PATIO COVER Type: PATIO Sub Type: Job Address: 2751 ASCOT AV Suite: Lot 0 Location: OWNER CHONG FAMILY TRUST 05-11-05 Owner: CHONG FAMILY TRUST 05-11-05 Remarks: Inspector Assignment: RB Phone: 7605095900 Inspector: Total Time: CD Description 19 Final Structural Act Comment Comments/Notices/Hold Requested By: DAVID Entered By: CHRISTINE Associated PCRs/CVs Original PC# Inspection History Date Description Act Insp Comments 09/27/2006 11 Ftg/Foundation/Piers AP RB 4 FTGS . Typical deck For ledger tounit attachmentsee Section VI,I tern D. Joists(specify sizeand spacingper Table 1) Joist spacing Posts (specify size and spacing) Post spacing Continuous solid btocking between joists Girder (specify size per Table 3) Footing (specify size and spacing per Table 4) Post-to-girder connection Case I/End condition Case 2/Interior condition Post cap instated per manufacturer's instaRason instructions Lrf.24" maximum Pro vide 4x4 knee brace ortop-to-botiombf ace on theinterior side ofall post-tcnbeam connections when postheight exceeds 4--0- Two V2-0 lag bolts top and bottom typical Post cap installed per manufacturer's instalation instructions Minimum Rafter Sizes Rafter Span 6 7 8 9 <*V 11 12 13 14 15 16 17 18 19 20 Rafter Spacing - Center to Center (in inches) 12" (5/1 6" ply- wood sheathing) 2x4 2x4 2x4 2x4 2x6 2x6 .-2x6 2x6 2x6 2x6 2x8 2x8 2x8 2x8 2x8 ^y(1/2"ply- '"wood sheathing) 2x4 2x4 2x4 2_x£_ <T"2x6y 2x6 2x6 2x6 2x6 2x8 2x8 2x8 2x8 2x10 2x10 24" (1/2" ply- wood sheathing) 2x4 2x4 2x6 2x6 2x6 2x6 2x6 2x8 2x8 2x8 2x8 2x10 2x10 2x10 2x10 32" (5/8" ply- wood sheathing) 2x4 2x4 2x6 2x6 2x6 2x8 2x8 2x8 2x8 2x10 2x10 2x10 2x10 2x12 2x12 NO GAS LINE MAY BE INSTALLED UNDER ANY PATIO COVER OR DECK Minimum Beam Sizes Post Spacing 4 6 8r$$ 12 14 16 18 20 Rafter Span (in feet) 4 4x4 4x4 4x4 4x4 4x6 4x6 4x8 4x8 4x8 6x8 6 4x4 4x4 4x4 4x6 4x6 4x8 4x8 4x8 6x8 4x10 6x8 8 4x4 4x4 4x6 4x6 4x8 4x8 4x8 6x8 4x10 6x8 4x10 6x10 (V4x4 4x4 4x6 4x0) 4x8 4x8 4x10 6x8 4x10 6x8 4x12 6x10 12 4x4 4x4 4x6 4x6 4x8 4x8 6x8 4x10 6x8 4x10 6x10 4x12 6x10 14 4x4 4x4 4x6 4x6 4x8 6x8 4x10 6x8 4x10 6x10 4x12 6x10 4x14 6x12 16 4x4 4x4 4x6 4x8 4x8 6x8 4x10 6x10 4x12 6x10 4x12 6x10 4x14 6x12 18 4x4,,.,* 4x4 4x6 4x8 4x8 6x8 4x10 6x10 4x12 6x10 4x14 6x12 6x12 20 4x4 4x6 4x6 4x8 4x10 6x8 4x10 6x10 4x14 6x10 4x14 6x12 6x14 TYPICAL R-1 PLOT PLAN SETBACKS FOR R-1 PARCELS FRONT YARD - 20* from front property ine INTERIOR SDE YARD -10% of lot width up to a maximum of 10-0*1.53 STREET SIDE YARD-10' REAR YARD - 20% Of tot wklh upto maximum 01 20 feet (MfrvIO1) MAX. LOT COVERAGE - 40% Contact the Planning Depart mart for Information on comer lots or lots wth unusual configurations and for Information on Planned ComtnunUes, accessory structures, and-buidng heights. The telephone number for the Planning Department Is 602-4601. LOT WCTH MEASURED 201 FROM 20-BACK OFFRONT PROPERTY UNE PROPERTY LJNE STREET Minimum Square Footing Sizes (inches)1'2 Post Spacing 4 6 8 tfoj) 12 14 16 18 20 _Rafter Span (in feet) 6 12 12 12 12 12 12 12 12 14 8 12 12 12 12 12 12 14 14 14 wT2 12 12 &S» 14 14 16 16 12 12 12 12 14 14 16 16 18 18 14 12 12 12 14 16 16 18 . 18 20 16 12 12 14 14 16 18 18 20 20 18 12 12 14 16 18 18 20 20 22 20 12 14 14 16 18 20 20 22 24 1. Assumes 1,000 psf soil bearing capacity 2. The minimum depth for all footings Is 12 inches Into natural grade