HomeMy WebLinkAbout2751 ASCOT AVE; ; CB062072; Permit07-19-2006
City of Carlsbad
1635 Faraday Av Carlsbad, CA 92008
Patio/Deck Permit Permit No:CB062072
Building Inspection Request Line (760) 602-2725
Job Address:
Permit Type:
Parcel No:
Valuation:
Reference #:
Project Title:
2751 ASCOT AV CBAD
PATIO
2131811400 Lot#: 0
$1,080.00 Construction Type: NEW
CHONG RES-120 SF PATIO COVER
Applicant:
CHONG FAMILY TRUST 05-11-05
2751 ASCOT AVE
CARLSBAD CA 92009
Status: ISSUED
Applied: 07/19/2006
Entered By: RMA
Plan Approved: 07/19/2006
Issued: 07/19/2006
Inspect Area:
Plan Check*:
Owner:
CHONG FAMILY TRUST 05-11-05
2751 ASCOT AVE
CARLSBAD CA 92009
Building Permit
Add'l Building Permit Fee
Plan Check
Add'l Plan Check Fee
Strong Motion Fee
Renewal Fee
Add'l Renewal Fee
Other Building Fee
Additional Fees
TOTAL PERMIT FEES
$23.01
$0.00
$14.96
$0.00
$1.00
$0.00
$0.00
$0.00
$0.00
$38.97
Total Fees:$38.97 Total Payments To Date:$38.97 Balance Due:$0.00
Inspector:
FINAL APPROVAL
Date: fa Clearance:
NOTICE: Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively
referred to as "fees/exactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must
follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for
processing in accordance with Carlsbad Municipal Code Section 3.32.030, Failure to timely follow that procedure will bar any subsequent legal action to attack,
review, set aside, void, or annul their imposition.
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity
changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any
fees/exactions of which you have-previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired.
PERMIT APPLICATION
CITY OF CARLSBAD BUILDING DEPARTMENT
1635 Faraday Ave., Carlsbad, CA 92008
FOR OFFICE USE ONL
PLAN CHECK NO.
EST. VAL.. ;
Plan Ck. Deposit
Validated Bv
4.7r/ ft*e+Jc.Ai/
Address (include BIdg/Suite *)Business Name (at this address)
Legal Description Lot No.Subdivision Name/Number Unit No.Phase No.Total # of units
Assessor's Parcel #Existing Use Proposed Use
(Sec. 7031.6 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to Its
issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law
(Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code] or that he is exempt therefrom, and tha basis for the alleged
exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars 1*60011.
Name
State License #
Address
License Class
City State/Zip
City Business License #
Telephone *
Designer Name
State License #
Address City State/Zip Telephone
Workers' Compensation Declaration: I hereby affirm under penalty of perjury one of the following declarations:
Q I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance
of the work for which this permit is issued.
n I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is
issued. My worker's compensation insurance carrier and policy number are:
Insurance Company Policy No. Expiration Date
(THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS 1*100} OR L£SS>
G CERTIFICATE OF EXEMPTION: I certify that in the performance of the work for which this permit is issued, I shall not employ «ny person in any manner so as
to become subject to the Workers' Compensation Laws of California.
WARNING: Failure to secure workers' compensation coverage Is unlawful, end shaft subject an employer to criminal penalties and dvN fines up to one hundred
thousand dollars ($100,000), In addition to the cost of compensation, damages as provided for in Section 3706 of tha Labor code, interest and attorney's fees.
.SIGNATURE DATE
I hereby affirm that I am exempt from the Contractor's License Law for tha following reason:
P. I, as owner of the property or my employees with wages as their sole compensation, will do tha work and tha structure Es not intended or offered for sale
(Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does
such work himself or through his own employees, provided that such improvements are not Intended or offered for sale. If, however, the building or improvement ia
sold within one year of completion, tha owner-builder will have the burden of proving that he did not build or improve for the purpose of sale),
Q I, aa owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The
Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractors) licensed
pursuant to the Contractor's License Law).
I am exempt under Section Business and Professions Code for this reason:
I pwaonmlly plan to provide the major labor and materials for construction of the proposed property improvement. W YES QNO
I tiave/nave not) signed an application for a building permit for the proposed work.
I hivf contracted with the following person (firm) to provide the proposed construction (include name / address / phone number / contractors license number):
4. I plan to provide pontons of the work, but I twve hired the following person to cooidinata, supervise and provide the major work (Include name I address / phone
number / contractors license number): __
5. I will provide aome of the work, but I have contracted (hired) the following persons to provide the work Indicated {Include name / jddressj phone number / type
of work): . _. „ . /*/•
PROPERTY OWNER SIGNATURE
Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management end prevention
program under Sections 25506, 25533 or 25634 of the Presley-Tanner Hazardous Substance Account Act? D YES Q NO
Is tha applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? D YES D NO
Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? Q YES Q NO
IF ANY OF THE ANSWERS ARE YES. A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE
REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT.
I hereby affirm that there is a construction fending agency for the performance of tha work lot which this permit is issued {Sec. 3097W Civil Code).
LENDER'S NAME LENDER'S ADDRESS
I certify that 1 have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all
City ordinances and State laws relating to building construction. I hereby authorize representatives of the City of Carlsbad to enter upon the above mentioned
property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES
JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT.
OSHA: An OSHA permit is required for excavations over 5'0" deep and demolition or construction of structures over 3 stories in height.
EXPIRATION: Every permit issued by the building Official under the provisions of this Code shall expire by limitation and become nu« and void «the bulldino or work
authorized by such permit is not commenced within 100 days from the date of such permit or if the building or work authorized by such permit is suspended or abandoned
*s£t any time after the work is commenced for a oeriod of 180 daysrfSectipr/l 06.4.4 Uniform Building Code). •*
APPLICANT'S SIGNATURE $-*7M**^~V ^L^V^^ DAJE
City of Carlsbad Bldg Inspection Request
For: 10/11/2006
Permit* CB062072
Title: CHONG RES-120SF FREE STANDING
Description: PATIO COVER
Type: PATIO Sub Type:
Job Address: 2751 ASCOT AV
Suite: Lot 0
Location:
OWNER CHONG FAMILY TRUST 05-11-05
Owner: CHONG FAMILY TRUST 05-11-05
Remarks:
Inspector Assignment: RB
Phone: 7605095900
Inspector:
Total Time:
CD Description
19 Final Structural
Act Comment
Comments/Notices/Hold
Requested By: DAVID
Entered By: CHRISTINE
Associated PCRs/CVs Original PC#
Inspection History
Date Description Act Insp Comments
09/27/2006 11 Ftg/Foundation/Piers AP RB 4 FTGS
. Typical deck
For ledger tounit attachmentsee Section VI,I tern D.
Joists(specify sizeand spacingper Table 1)
Joist
spacing
Posts
(specify size
and spacing)
Post spacing
Continuous
solid btocking
between joists
Girder (specify
size per Table 3)
Footing (specify size and
spacing per Table 4)
Post-to-girder connection
Case I/End condition Case 2/Interior condition
Post cap
instated per
manufacturer's
instaRason
instructions
Lrf.24" maximum Pro vide 4x4
knee brace ortop-to-botiombf ace on theinterior side ofall post-tcnbeam
connections
when postheight exceeds
4--0-
Two V2-0 lag
bolts top and
bottom typical
Post cap
installed per
manufacturer's
instalation
instructions
Minimum Rafter Sizes
Rafter
Span
6
7
8
9
<*V
11
12
13
14
15
16
17
18
19
20
Rafter Spacing - Center to Center (in inches)
12" (5/1 6" ply-
wood sheathing)
2x4
2x4
2x4
2x4
2x6
2x6
.-2x6
2x6
2x6
2x6
2x8
2x8
2x8
2x8
2x8
^y(1/2"ply-
'"wood sheathing)
2x4
2x4
2x4
2_x£_
<T"2x6y
2x6
2x6
2x6
2x6
2x8
2x8
2x8
2x8
2x10
2x10
24" (1/2" ply-
wood sheathing)
2x4
2x4
2x6
2x6
2x6
2x6
2x6
2x8
2x8
2x8
2x8
2x10
2x10
2x10
2x10
32" (5/8" ply-
wood sheathing)
2x4
2x4
2x6
2x6
2x6
2x8
2x8
2x8
2x8
2x10
2x10
2x10
2x10
2x12
2x12
NO GAS LINE MAY BE INSTALLED UNDER ANY PATIO COVER OR DECK
Minimum Beam Sizes
Post
Spacing
4
6
8r$$
12
14
16
18
20
Rafter Span (in feet)
4
4x4
4x4
4x4
4x4
4x6
4x6
4x8
4x8
4x8
6x8
6
4x4
4x4
4x4
4x6
4x6
4x8
4x8
4x8
6x8
4x10
6x8
8
4x4
4x4
4x6
4x6
4x8
4x8
4x8
6x8
4x10
6x8
4x10
6x10
(V4x4
4x4
4x6
4x0)
4x8
4x8
4x10
6x8
4x10
6x8
4x12
6x10
12
4x4
4x4
4x6
4x6
4x8
4x8
6x8
4x10
6x8
4x10
6x10
4x12
6x10
14
4x4
4x4
4x6
4x6
4x8
6x8
4x10
6x8
4x10
6x10
4x12
6x10
4x14
6x12
16
4x4
4x4
4x6
4x8
4x8
6x8
4x10
6x10
4x12
6x10
4x12
6x10
4x14
6x12
18
4x4,,.,*
4x4
4x6
4x8
4x8
6x8
4x10
6x10
4x12
6x10
4x14
6x12
6x12
20
4x4
4x6
4x6
4x8
4x10
6x8
4x10
6x10
4x14
6x10
4x14
6x12
6x14
TYPICAL R-1 PLOT PLAN
SETBACKS FOR R-1 PARCELS
FRONT YARD - 20* from front
property ine
INTERIOR SDE YARD -10% of
lot width up to a maximum of
10-0*1.53
STREET SIDE YARD-10'
REAR YARD - 20% Of tot wklh
upto maximum 01 20 feet (MfrvIO1)
MAX. LOT COVERAGE - 40%
Contact the Planning Depart mart
for Information on comer lots or
lots wth unusual configurations
and for Information on Planned
ComtnunUes, accessory
structures, and-buidng
heights.
The telephone number for the
Planning Department Is
602-4601.
LOT WCTH MEASURED 201
FROM 20-BACK OFFRONT PROPERTY UNE
PROPERTY LJNE
STREET
Minimum Square Footing Sizes (inches)1'2
Post
Spacing
4
6
8
tfoj)
12
14
16
18
20
_Rafter Span (in feet)
6
12
12
12
12
12
12
12
12
14
8
12
12
12
12
12
12
14
14
14
wT2
12
12
&S»
14
14
16
16
12
12
12
12
14
14
16
16
18
18
14
12
12
12
14
16
16
18
. 18
20
16
12
12
14
14
16
18
18
20
20
18
12
12
14
16
18
18
20
20
22
20
12
14
14
16
18
20
20
22
24
1. Assumes 1,000 psf soil bearing capacity
2. The minimum depth for all footings Is 12 inches Into natural grade