Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
2753 JEFFERSON ST; ; CB063330; Permit
01-02-2008 Job Address Permit Type Parcel No Valuation Occupancy Group Project Title City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Commercial/Industrial Permit Permit No Building Inspection Request Line (760) 602-2725 CB063330 2753 JEFFERSON ST CBAD COMMIND Sub Type COMM 2031101400 Lot# 0 $424 033 00 Construction Type NEW Reference # CB054002 TUSCANY OFFICE BLDG 3093 SF OFFICE 3800 SF GARAGE 893SF BALCONY Applicant DALY WILLIAM V&ROSA C P O BOX 260 CARLSBAD CA 92018 Status Applied Plan Approved Issued Inspect Area Plan Check# TTTZTOOOe Entered By KG Owner DALY WILLIAM V&ROSA C P 0 BOX 260 CARLSBAD CA 92018 Building Permit Add I Building Permit Fee Plan Check Add I Plan Check Fee Plan Check Discount Strong Motion Fee Park Fee LFM Fee Bridge Fee BTD #2 Fee BTD #3 Fee Renewal Fee Add I Renewal Fee Other Building Fee Pot Water Con Fee Meter Size Add I Pot Water Con Fee Reel Water Con Fee $1 547 56 Meter Size $0 00 Add I Reel Water Con Fee $1 005 91 Meter Fee $0 00 SDCWA Fee $0 00 CFD Payoff Fee $8905 PFF (3105540) $0 00 PFF (4305540) $000 License Tax (3104193) $0 00 License Tax (4304193) $000 Traffic Impact Fee (3105541) $0 00 Traffic Impact Fee (4305541) $0 00 PLUMBING TOTAL $0 00 ELECTRICAL TOTAL $0 00 MECHANICAL TOTAL $15 254 00 Master Drainage Fee D1 Sewer Fee $0 00 Redev Parking Fee $0 00 Additional Fees HMP Fee TOTAL PERMIT FEES $000 $440 00 $1380200 $000 $771740 $712375 $000 $000 $1 450 80 $1 339 20 $21000 $31000 $131 50 $469 82 $1 800 84 $22 480 00 $574 00 $000 $75 745 83 Total Fees $75 745 83 Total Payments To Date $448 95 Balance Due $75 296 88 Inspector FINAL APPROVAL Date Clearance NOTICE Please take NOTICE that approval of your project includes the Imposition of fees dedications reservations or other exactions hereafter collectively referred to as fees/exactions You have 90 days from the date this permit was issued to protest imposition of these fees/exactions If you protest them you must follow the protest procedures set forth in Government Code Section 66020(a) and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3 32 030 Failure to timely follow that procedure will bar any subsequent legal action to attack review set aside void or annul their imposition You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes nor planning zoning grading or other similar application processing or service fees in connection with this project NOR DOES IT APPLY to any fees/exactions of which you have Previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise exwred PERMIT APPLICATION CITY OF CARLSBAD BUILDING DEPARTMENT 1635 Faraday Ave Carlsbad CA 92008 FT PROJECT INFORMATION Si: FOR OFFICE USE ONLY PLAN CHECK NO EST VAL ; Plan Ck Deposit Validated By , Date H f 2 > Address (include BIdg/Suite #)Business Name (at this address) Legal Description Lot No Subdivision Name/Number Unit No 1T2/Z. Phase No Total # of units 1 UP} Assessor's Parcel #Existing Use Proposed Use Description of Work SQ FT # of Stones # of Bedrooms * of Bathrooms 0°>3 S3= OPf\C^A Q°[ ^CONTACTP^SONlrflfe^t frorh fe:frllcant) Name Address City State/Zip \3 APPU gaAtZ-Tr 5 Telephone #Fax* APPLICANT D Contractor D Agent for Contractor D Owner €8?.£ ls/6,1 IS/ YT/>5 Agent for Owner Name Address City State/Zip Telephone # [4 PROPERTY OWNER Name Address City State/Zip Telephone # CONTRACTOR COMPANY NAME (Sec 70315 Business and Professions Code Any City or County which requires a permit to construct after improve demolish or repair any structure prior to its issuance also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law [Chapter 9 commending with Section 7000 of Division 3 of the Business and Professions Code] or that he is exempt therefrom and the basis for the alleged exemption Any violation of Section 7031 5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars [$500]) Name State License # Designer Name State License # Address License Class Address City City State/Zip Ctrv Business License # State/Zip Telephone # Telephone # )6 WORKERS COMPENSATION Workers Compensation Declaration I hereby affirm under penalty of perjury one of the following declarations O I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code for the performance of the work for which this permit is issued O I have and will maintain worker's compensation as required by Section 3700 of the labor Code for the performance of the work for which this permit is issued My worker's compensation insurance earner and policy number are Insurance Company. Policy No Expiration Date (THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS {$100] OR LESS) O CERTIFICATE OF EXEMPTION I certify that in the performance of the work for which this permit is issued I shall not employ any person in any manner so as to become subject to the Workers Compensation Laws of California WARNING Failure to secure workers compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars<$100 000) In addition to the cost of compensation damages are provided for in Section 3706 of the Labor Code, Merest and attorney's fee SIGNATURED DATE I hereby affirm that I am exempt from the Contractor's License Law for the following reason 0 I as owner of the property or my employees with wages as their sole compensation will d the work and the structure is not intended or offered for sale (Sec. 7044 Business and Professions Code The Contractor's License Law does not apply to an owner of property who builds or improves thereon and who does such work himself or through his own employees provided that such improvements are not intended or offered for sale If however the building or improvement is sold within one year of completion the owner builder will have the burden of proving that he did not build or improve for the purpose of sale) ^f\ I as owner of the property am exclusively contracting with licensed contractors to construct the project (Sec 7044 Business and Professions Code The Contractor's License Law does not apply to an owner of property who builds or improves thereon and contracts for such projects with contraotor(s) licensed pursuant to the Contractor's License Law) D I am exempt under Section Business and Professions Code for this reason 1 [89|:B0^ally P18"to Provide the major labor and materials for construction of the proposed property improvement D YES jjf NO 2 luhavwhave not) signed an application for a building permit for the proposed work 3 I hare contracted with the following person (firm) to provide the proposed construction (include name / address / phone number / contractors license number) 4. S -TAJ) I plan to provide portioi portions of the work, but I have hired the following person to coordinate supervise and provide the major work (include name / address / phone number / tontractors license number) I will provide some of the work, but I have contracted (hji /typeofwprfc)ifwprfc) PROPERTY OWNER SIGNATURE WHITE Fite YELLOW Applicant PINK. Finance PERMIT APPLICATION CITY OF CARLSBAD BUILDING DEPARTMENT 1635 Faraday Ave Carlsbad CA 92008 Page 2 of 2 [COMPLETE THIS SECTION FOR NON-RESIDENTIAL BUILDING PERMITS ONLY Is the applicant or future building occupant required to submit a business plan acutely hazardous materials registration for or nsk management and prevention program under Sections 25505 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? DYES D NO Is the applicant or future building occupant required to obtain a permit from the air pollution control distnct or air quality management distnct? D YES D NO Is the faalrty to be constructed within 1000 feet of the outer boundary of a school site? D YES D NO IF ANY OF THE ANSWERS ARE YES A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT J8~~CbNSTRUCTION LENDING AGENCY ~ [ I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec 3097(1) Civil Code) LENDERS NAME LENDERS ADDRESS 19 APPLICANT CERTIFICATION I certify that I nave read the application and state that the above information is correct and that the information on the plans is accurate I agree to comply with all City ordinances and State laws relating to building construction I hereby authorize representatives of the City of Carlsbad to enter upon the above mentioned property for inspection purposes I ALSO AGREE TO SAVE INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES JUDGEMENTS COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT OSHA An OSHA permit is required for excavations of 5 0* deep and demolition or construction of structures over 3 stones in height EXPIRATION Every permit issued by the building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such-permit or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced fora period of 180 days [Section 1064 4 Uniform Building Code) APPLICANTS SIGNATURE . < c vv^_^ VV-- DATE K/10/o WHITE File YELLOW Applicant PINK Finance City of Carlsbad Bu i Iding Department SEPTEMBER 4, 2007 BART SMITH 682 2ND ST ENCINITAS CA 92024 RE APPLICATION DATE 11/21/2006 PLAN CHECKS CB063330 ADDRESS 2753 JEFFERSON ST EXPIRATION DATE 11/21/2007 PERMIT TYPE COMMIND DESCRIPTION TUSCANY OFFICE BLDG 3093 SF OFFICE 3800 SF GARAGE You applied to have your plans checked on the date noted above To date, the related building permit has not been obtained The original plan review application will expire as no building permit has been issued Plans submitted and not retrieved from the building department prior to the plan check expiration date noted above will be destroyed The provisions of sections 304 (d) of the Uniform Building Code state "Section 304 9d) Expiration of Plan Review Applications for which no permit is issued within one year following the date of application shall expire by limitation and plans and other data submitted for review may thereafter be returned to the applicant or destroyed by the Building Official In order to renew action on an application after expiration, the applicant shall resubmit plans and pay a new plan review fee ' In order to provide better service, please indicate your handling choice for the plans originally submitted and return this letter to the Building Department Project Abandoned -1 will pick up the plans within 10 days Project Abandoned - Plans may be destroyed If you have any questions please contact the Building Department at (760) 602 2719 Building Department 1635 Faraday Avenue • Carlsbad CA 92008 • (760) 602 4660 • FAX (760) 602 8561 City of Carlsbad Building Department September 5, 2006 BART SMITH 682 2ND ST ENCINITASCA 92024 RE APPLICATION DATE 11/17/2005 PLAN CHECK # CB054002 ADDRESS 2753 JEFFERSON ST EXPIRATION DATE 11/17/2006 PERMIT TYPE COMMIND DESCRIPTION TUSCANY OFFICE BLDG - 3093SF OFFICE 3800SF GARAGE You applied to have your plans checked on the date noted above To date the related building permit has not been obtained The original plan review application will expire as no building permit has been issued Plans submitted and not retrieved from the building department prior to the plan check expiration date noted above will be destroyed The provisions of sections 304 (d) of the Uniform Building Code state Section 304 9d) Expiration of Plan Review Applications for which no permit is issued within one year following the date of application shall expire by limitation and plans and other data submitted for review may thereafter be returned to the applicant or destroyed by the Building Official In order to renew action on an application after expiration the applicant shall resubmit plans and pay a new plan review fee In order to provide better service please indicate your handling choice for the plans originally submitted and return this letter to the Building Department Project Abandoned -1 will pick up the plans within 10 days Project Abandoned - Plans may be destroyed If you have any questions please contact the Building Department at (760) 602 2719 Building Department 1635 Faraday Avenue • Carlsbad CA 920O8 7314 • (760) 6O2 270O Building Counter • (760) 602 2719 • FAX (760) 602 8558 EsGil Corporation In Partnership with government for 'Building Safety DATE September 11, 2006 Q APPLICANT -Q^JURIS JURISDICTION Carlsbad a PLAN REVIEWER a FILE PLAN CHECK NO 05-4002 SET III PROJECT ADDRESS 2753 Jefferson St PROJECT NAME Tuscany Office Suites XI The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction s building codes The plans transmitted herewith will substantially comply with the jurisdiction s building codes when minor deficiencies identified below are resolved and checked by building department staff [ | The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck The check list transmitted herewith is for your information The plans are being held at Esgil Corporation until corrected plans are submitted for recheck The applicant s copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person The applicant s copy of the check list has been sent to XI Esgil Corporation staff did not advise the applicant that the plan check has been completed Esgil Corporation staff did advise the applicant that the plan check has been completed Person contacted Telephone # Date contacted (by ) Fax # Mail Telephone Fax In Person REMARKS The floor areas reported on sheet A 1 now include the garage By Kurt Culver Enclosures Esgil Corporation D GA D MB D EJ D PC 9/6/06 trnsmtldot 9320 Chesapeake Drive Suite 208 * San Diego California 92123 *• (858)560 1468 4 Fax (858) 560 1576 EsGil Corporation In Partnership with government for 'Bmld.vng Safety DATE June 13, 2006 ^JURISDICTION Carlsbad a PLAN REVIEWER a FILE PLAN CHECK NO 05-4002 SET II PROJECT ADDRESS 2753 Jefferson St PROJECT NAME Tuscany Office Suites I | The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction s building codes The plans transmitted herewith will substantially comply with the jurisdiction s building codes when minor deficiencies identified below are resolved and checked by building department staff The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck The check list transmitted herewith is for your information The plans are being held at Esgil Corporation until corrected plans are submitted for recheck The applicant s copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person 1X1 The applicant s copy of the check list has been sent to Bart Smith 682 2nd St Encmitas CA 92024 Esgil Corporation staff did not advise the applicant that the plan check has been completed XI Esgil Corporation staff did advise the applicant that the plan check has been completed Person contacted Bart Smith Telephone # (760) 753 2464 Date contacted (£>\\^[o(p (by (c*-)- Fax # 0600 Mail Telephone Fax^ In Person REMARKS By Kurt Culver Enclosures Esgil Corporation D GA D MB E] EJ D PC 6/6/06 trnsmtldot 9320 Chesapeake Drive Suite 208 + San Diego California 92123 + (858)5601468 * Fax (858) 560 1576 Carlsbad 05-4002 June 13, 2006 RECHECK PLAN CORRECTION LIST JURISDICTION Carlsbad PROJECT ADDRESS 2753 Jefferson St DATE PLAN RECEIVED BY ESGIL CORPORATION 6/6/06 REVIEWED BY Kurt Culver PLAN CHECK NO 05-4002 SET II DATE RECHECK COMPLETED June 13, 2006 FOREWORD (PLEASE READ) This plan review is limited to the technical requirements contained in the Uniform Building Code Uniform Plumbing Code Uniform Mechanical Code National Electrical Code and state laws regulating energy conservation noise attenuation and disabled access This plan review is based on regulations enforced by the Building Department You may have other corrections based on laws and ordinances enforced by the Planning Department Engineering Department or other departments The following items listed need clarification modification or change All items must be satisfied before the plans will be in conformance with the cited codes and regulations Per Sec 106 4 3 1997 Uniform Building Code the approval of the plans does not permit the violation of any state county or city law A To facilitate recheckmg, please identify, next to each item, the sheet of the plans upon which each correction on this sheet has been made and return this sheet with the revised plans B The following items have not been resolved from the previous plan reviews The original correction number has been given for your reference In case you did not keep a copy of the prior correction list we have enclosed those pages containing the outstanding corrections Please contact me if you have any questions regarding these items C Please indicate here if any changes have been made to the plans that are not a result of corrections from this list If there are other changes please briefly describe them and where they are located on the plans Have changes been made not resulting from this list9 QYes QNo Carlsbad 05-4002 June 13, 2006 • GENERAL 1 Please make all corrections on the original tracings as requested in the correction list Submit three sets of plans for commercial/industrial projects (two sets of plans for residential projects) For expeditious processing corrected sets can be submitted in one of two ways 1 Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department 1635 Faraday Ave Carlsbad CA 92008 (760)6022700 The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments 2 Bring one corrected set of plans and calculations/reports to EsGil Corporation 9320 Chesapeake Drive Suite 208 San Diego CA 92123 (858)560-1468 Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning Engineering and Fire Departments 2 When special inspection is required the architect or engineer of record shall prepare an inspection program which shall be submitted to the building official for approval prior to issuance of the building permit Please review Section 106 3 5 Please complete the City of carisbad form TO THE LIST OF ITEMS ON THE LIST PLEASE INCLUDE SPRAY ON FIREPROOFING PLANS 3 All sheets of the plans and the first sheet of the calculations are required to be signed by the California licensed architect or engineer responsible for the plan preparation Please include the California license number seal date of license expiration and the date the plans are signed Business and Professions Code THIS WILL BE VERIFIED WITH THE FINAL PLANS 4 Please revise the Project Data to include the occupancy classification of the garage Also report the garage floor area along with the total building floor area Further change the NEC edition to 2002 WE WILL ADVISE CITY STAFF OF THE AREAS LOCATION ON PROPERTY 5 The exterior walls less than 20 feet to a property line shall be 1 hour fire rated construction Section 503 a) Ploaso provide a logond on tho floor piano to chow which walls will be rated (and roforonce a detail to show how) b) Additionally provide special detailing to show how the moment frame columns will be protected FOR THE W SHAPED COLUMNS PLEASE PROVIDE DETAILING TO SHOW HOW 1 HOUR PROTECTION WILL BE PROVIDED 6 Exterior walls shall have a 30 inch parapet when less than 10 feet to a property line The uppermost 18 of such parapets shall be noncombustible (see exceptions Section 709 4) A ON SHEET M 2 PLEASE SHOW ALL THE REQUIRED FIRE DAMPERS AT THE CEILING B ON SHEET A 5 THE S VENTS CANNOT OCCUR WITHIN 10 OF THE PROPERTY LINE 7 The exterior wall shall have protected openings (3/4 hour) when closer than 10 feet to a property line or an assumed property line Section 503 d) Further see the mechanical penetrations on sheet M 2 ON SHEET M 2 PLEASE SPECIFY FIRE DAMPERS FOR THE LOUVERS IN THE EXTERIOR WALL Carlsbad 05-4002 June 13, 2006 CORRIDORS (At the second floor) 1 6 Corridors shall have interior door openings protected by tight fitting smoke and draft control assemblies rated 20 minutes Doors shall be maintained self closing or be automatic closing by action of a smoke detector per Section 713 2 Doors shall be gasketed to provide a smoke and draft seal where the door meets the stop on sides and top Section 1004 34321 DOOR EISA 20 MINUTE ASSEMBLY BUT THE SCHEDULE SHOWS THAT THIS DOOR WILL BE TYPE C WHICH IS A FRENCH DOOR PLEASE JUSTIFY HAVING SO MUCH GLASS IN A 20-MINUTE DOOR ADDITIONAL To speed up the review process note on this list (or a copy) where each correction item has been addressed i e plan sheet note or detail number calculation page etc Please indicate here if any changes have been made to the plans that are not a result of corrections from this list If there are other changes please briefly describe them and where they are located in the plans Have changes been made to the plans not resulting from this correction list7 Please indicate a Yes Q No The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive Suite 208 San Diego California 92123 telephone number of 858/560 1468 to perform the plan review for your project If you have any questions regarding these plan review items please contact Kurt Culver at Esgil Corporation Thank you EsGil Corporation In Partnership imth government for Quilting Safety DATE December 5, 2005 O_AEEUCANT JURISDICTION Carlsbad a PLAN REVIEWER a FILE PLAN CHECK NO 05-4002 SET I PROJECT ADDRESS 2753 Jefferson St PROJECT NAME Tuscany Office Suites I | The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction s building codes I | The plans transmitted herewith will substantially comply with the jurisdiction s building codes when minor deficiencies identified below are resolved and checked by building department staff I | The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck 1X1 The check list transmitted herewith is for your information The plans are being held at Esgil Corporation until corrected plans are submitted for recheck The applicant s copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person The applicant s copy of the check list has been sent to Bart Smith 682 2nd St Encmitas CA 92024 [~| Esgil Corporation staff did not advise the applicant that the plan check has been completed 1X1 Esgil Corporation staff did advise the applicant that the plan check has been completed Person contacted Bart Smith Telephone # (760) 753 2464 Date contacted (2.| (p fftt, (by \fld-) Fax # 0600 Mail Telephone Vx/Fax u/fn Person REMARKS By Kurt Culver Enclosures Esgil Corporation D GA D MB El EJ D PC 11/21/05 trnsmtldot 9320 Chesapeake Drive Suite 208 4 San Diego California 92123 * (858)560 1468 + Fax (858) 560 1576 Carlsbad O5-4002 December 5, 2005 PLAN REVIEW CORRECTION LIST COMMERCIAL PLAN CHECK NO 05-4002 OCCUPANCY B/S-3 TYPE OF CONSTRUCTION V-N ALLOWABLE FLOOR AREA OK SPRINKLERS'? Yes REMARKS DATE PLANS RECEIVED BY JURISDICTION 11/17/05 DATE INITIAL PLAN REVIEW COMPLETED December 5, 2005 JURISDICTION Carlsbad USE Office/Parking ACTUAL AREA 6893 STORIES 2 HEIGHT 30 OCCUPANT LOAD 45 DATE PLANS RECEIVED BY ESGIL CORPORATION 11/21/05 PLAN REVIEWER Kurt Culver FOREWORD (PLEASE READ) This plan review is limited to the technical requirements contained in the Uniform Building Code Uniform Plumbing Code Uniform Mechanical Code National Electrical Code and state laws regulating energy conservation noise attenuation and access for the disabled This plan review is based on regulations enforced by the Building Department You may have other corrections based on laws and ordinances enforced by the Planning Department Engineering Department Fire Department or other departments Clearance from those departments may be required prior to the issuance of a building permit Code sections cited are based on the 1997 UBC The following items listed need clarification modification or change All items must be satisfied before the plans will be in conformance with the cited codes and regulations Per Sec 106 4 3 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state county or city law To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i e. plan sheet number, specification section, etc Be sure to enclose the marked up list when you submit the revised plans Carlsbad 05-4002 December 5, 2005 • GENERAL 1 Please make all corrections on the original tracings as requested in the correction list Submit three sets of plans for commercial/industrial projects (two sets of plans for residential projects) For expeditious processing corrected sets can be submitted in one of two ways 1 Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave Carlsbad, CA 92008 (760) 602 2700 The City will route the plans to EsGil Corporation and the Carlsbad Planning Engineering and Fire Departments 2 Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive Suite 208 San Diego CA 92123 (858)5601468 Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning Engineering and Fire Departments 2 When special inspection is required the architect or engineer of record shall prepare an inspection program which shall be submitted to the building official for approval prior to issuance of the building permit Please review Section 106 3 5 Please complete the attached City of Carlsbad form • PLANS 3 All sheets of the plans and the first sheet of the calculations are required to be signed by the California licensed architect or engineer responsible for the plan preparation Please include the California license number, seal, date of license expiration and the date the plans are signed Business and Professions Code 4 Please revise the Project Data to include the occupancy classification of the garage Also report the garage floor area along with the total building floor area Further change the NEC edition to 2002 • LOCATION ON PROPERTY 5 The exterior walls less than 20 feet to a property line shall be 1 hour fire rated construction Section 503 a) Please provide a legend on the floor plans to show which walls will be rated (and reference a detail to show how) b) Additionally provide special detailing to show how the moment frame columns will be protected 6 Exterior walls shall have a 30 inch parapet when less than 10 feet to a property line The uppermost 18 of such parapets shall be noncombustible (see exceptions Section 709 4) Carlsbad O5-4002 December 5, 2005 7 The exterior wall shall have protected openings (3/4 hour) when closer than 10 feet to a property line or an assumed property line Section 503 a) Please specify in the door schedule the hourly rating for the doors b) Additionally, see all the windows at the second floor' c) Additionally, an opening is formed at the gates which provide access to the Waste area Provide protected doors there d) Further, see the mechanical penetrations on sheet M-2 8 Combustible projections located where openings are required to be protected shall be heavy timber or one-hour construction Section 705 9 Projections may not extend more than 12 inches into areas where openings are not allowed Section 503 2 1 • OCCUPANCY SEPARATION 10 A 1-hour occupancy separation is required between the S-3 occupancy and the B occupancy Table 3 B Section 302 2 Please detail the required construction a) Also maintain the occupancy separation along the side of the stair facing the garage (on sheet A 3 by Suite 1) 11 Provide 1 hour fire-resistive door assemblies in the 1-hour occupancy separation Section 302 3 Not 45 minute 12 Structural members supporting an occupancy separation must have the same fire resistive rating as the separation Section 302 2 13 Structural members such as beams supporting more than one floor or roof must be individually fire protected (Section 704 2 6) Detail required protection 14 Detail column fire protection and specify column impact protection in garage areas per Section 704 2 5 As a minimum show a 22 ga steel jacket around each column to a height of 3 feet above the ground for impact protection • CORRIDORS (At the second floor) 15 Detail on the plans the fire resistive construction for the corridor system 16 Corridors shall have interior door openings protected by tight fitting smoke and draft control assemblies rated 20 minutes Doors shall be maintained self closing or be automatic closing by action of a smoke detector per Section 713 2 Doors shall be gasketed to provide a smoke and draft seal where the door meets the stop on sides and top Section 1004 34321 17 The total area of windows in any portion of an interior corridor shall not exceed 25 percent of the area of a common wall with any room Such openings shall be protected by fixed glazing listed and labeled for a fire protection rating of at least 3/4 hour Section 1004 3 4 3 2 2 Carlsbad 05-4002 December 5, 2005 • GLASS AND GLAZING 18 Glazing in the following locations should be of safety glazing material in accordance with Section 2406 4 (see exceptions) a) Fixed or operable panels adjacent to a door where the nearest exposed edge of the glazing is within a 24-inch arc of either vertical edge of the door in a closed position and where the bottom exposed edge of the glazing is less than 60 inches above the walking surface b) Walls enclosing stairway landings or within 5 feet of the bottom and top of stairways where the bottom edge of the glass is less than 60 inches above a walking surface • ROOFS 19 Specify on the plans the following information for the roof materials per Section 10633 a) Manufacturers name b) Product name/number c) ICBO approval number or equal 20 Specify minimum 1/4 inch per foot slope for decks and balconies Section 14023 21 Show location of attic access with a minimum size of 22 x30" unless the maximum vertical headroom height in the attic is less than 30 " Access must be provided to each separated attic area shall be located in a hallway or other readily accessible location and 30 headroom clearance is required above the opening Section 1505 1 • MISCELLANEOUS LIFE/SAFETY 22 Guardrails (Section 509 1) a) Shall have a height of 42 b) Shall be detailed showing adequacy of connections to resist the horizontal force prescribed in Table 16 B c) Openings between railings shall be less than 4 The triangular openings formed by the riser tread and bottom element of a guardrail at a stair shall be less than 6' • TITLE 24 DISABLED ACCESS 23 Provide notes and details on the plans to show compliance with the enclosed Disabled Access Review List Disabled access requirements may be more restrictive than the UBC Carlsbad 05-4002 December 5, 2005 FOUNDATION 24 Provide a copy of the project soil report prepared by a California licensed architect or civil engineer The report shall include foundation design recommendations based on the engineer's findings and shall comply with UBC Section 1804 We only received a 3/12/04 letter (and it s missing sheets following the liquefaction discussion) 25 Provide a letter from the soils engineer confirming that the foundation plan grading plan and specifications have been reviewed and that it has been determined that the recommendations in the soil report are properly incorporated into the plans (when required by the soil report) 26 Specify on the foundation plan or structural specifications sheet the soil classification the soils expansion index and the design bearing capacity of the foundation Section 106 3 3 27 Note on plans that surface water will dram away from building and show drainage pattern Section 1804 7 28 On sheet S2 0 the pad footing below the reaction of FB24 must be shifted over a few feet so that it lines up with the other pad footing • STRUCTURAL 29 Provide minimum structural specifications on the plans to show that all structural materials will comply with the design calculations and building code requirements 30 Please provide evidence that the engineer of record (or architect) has reviewed the truss calculation package prepared by others (i e a review stamp on the truss calculations or a letter) Section 106 3 4 1 31 Which pages in the lateral calculations address chord forces9 32 Please provide a detail reference on the plans to show the connection of FB4 to FB7A etc 33 The framing calculations used the allowable stresses from the 2001 NDS (170 psi for shear etc) The 2001 CBC did not adopt that addition so please revise throughout Carlsbad 05-4002 December 5, 2OO5 • ADDITIONAL 34 Specify on the plans the following information for the fireplace(s) per Section 10633 a) Manufacturer s name b) Model name/number c) ICBO approval number or equal d) Show height of chimney above roof per ICBO approval or UBC Table 31 -B e) Note on the plans that approved spark arrestors shall be installed on all chimneys UBC Section 3102 3 8 35 Please justify the shroud mentioned in Note 77 on sheet A 6 Unless specifically allowed by the manufacturer of the chimney it must be removed 36 There are boxed notes on sheet A 3, but no schedule was provided to explain them 37 On sheet A 4 why does the stair handrail stop halfway down the flight near Suite 4? 38 Most of the Keynotes on sheet A-8 don t match up properly with the locations that they re referenced Please revise throughout Because of this a review of this sheet has not begun More time will be needed 39 Please clarify 1/A 40 Please see the following sheet for MEP corrections 41 To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i e plan sheet, note or detail number, calculation page etc 42 Please indicate here if any changes have been made to the plans that are not a result of corrections from this list If there are other changes please briefly describe them and where they are located in the plans Have changes been made to the plans not resulting from this correction list? Please indicate Q Yes Q No 43 The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive Suite 208 San Diego California 92123 telephone number of 858/560 1468, to perform the plan review for your project If you have any questions regarding these plan review items please contact Kurt Culver at Esgil Corporation Thank you Carlsbad 05-4002 December 5, 20O5 ELECTRICAL, ENERGY, PLUMBING, and MECHANICAL CORRECTIONS PLAN REVIEWER Eric Jensen 1 The licensed designer must sign the approved set of the plans ELECTRICAL (2002 NATIONAL ELECTRICAL CODE) 2 Provide a detail for the area that the building service is located The detail to include area dimensions utilities (gas meters) outside air duct equipment dimensions NEMA 3 enclosure layout (If it has doors be sure to show arrangement and width of doors) and the clearance between the 6 property line wall and the enclosure door locked in the fully open position 3 The elevator machine room convenience receptacles must be GFCI protected PLUMBING (2000 UNIFORM PLUMBING CODE) 4 Large instantaneous water heaters are specified (For a lavatory9) Provide complete installation instructions including locations access, and combustion air (Maintenance of envelope) MECHANICAL (2000 UNIFORM MECHANICAL CODE) 5 Check with the State Agency (Elevator Safety Unit 1 (916) 263 2830) to see if ductwork is allowed to be installed in the elevator machinery room 6 Trace the occupancy separation from the parking garage to the roof with the garage exhaust fan system Provide dampers shafts rated construction and rated doors where necessary Note If you have any questions regarding this Electrical Plumbing Mechanical and Energy plan review list please contact Eric Jensen at (858) 560-1468 To speed the review process note on this list (or a copy) where the corrected items have been addressed on the plans Carlsbad 05-4002 December 5, 2005 DISABLED ACCESS REVIEW LIST DEPARTMENT OF STATE ARCHITECT TITLE 24 The following disabled access items are taken from the 2001 edition of California Building Code, Title 24 Per Section 1011711 all publicly and privately funded public accommodations and commercial facilities shall be accessible to persons with disabilities NOTE All Figures and Tables referenced in this checklist are printed in the California Building Code Title 24 ACCESSIBLE PARKING 1 Show that all vertical entrances to and vertical clearances within parking structures have a vertical clearance of >8 -2 where required for access to accessible parking spaces per Section 1130B DOORS Show that the minimum strike edge distances are provided at the level area on the side to which a door (or a gate) swings per Section 1133B 243 a) >24 at exterior conditions SHOW THIS FOR THE BALCONY DOORS AT THE UPPER LEVEL b) Also specify on the plans the threshold height at those doors • SIGNAGE Per Section 1003 2861 tactile exit signs shall be required at the following locations a) Wherever basic UBC provisions require exit signs from a room or area to a corridor or hallway The tactile exit sign shall have the words EXIT ROUTE b) Each grade level exit door The tactile exit sign shall have the word EXIT c) Each exit door that leads directly to a grade level exterior exit by means of a stairway or ramp The tactile exit sign shall have the following words as appropriate i) EXIT STAIR DOWN End Carlsbad 05-4002 December 5, 2005 City of Carlsbad Building Department BUILDING DEPARTMENT NOTICE OF REQUIREMENT FOR SPECIAL INSPECTION Do Not Remove From Plans Plan Check No 05-4002 Job Address or Legal Description 2753 Jefferson St Owner Address You are hereby notified that in addition to the inspection of construction provided by the Building Department an approved Registered Special Inspector is required to provide continuous inspection during the performance of the phases of construction indicated on the reverse side of this sheet The Registered Special Inspector shall be approved by the City of Carlsbad Building Department prior to the issuance of the building permit Special Inspectors having a current certification from the City of San Diego Los Angeles or ICBO are approved as Special Inspectors for the type of construction for which they are certified The inspections by a Special Inspector do not change the requirements for inspections by personnel of the City of Carlsbad building department The inspections by a Special Inspector are in addition to the inspections normally required by the County Building Code The Special Inspector is not authorized to inspect and approve any work other than that for which he/she is specifically assigned to inspect The Special Inspector is not authorized to accept alternate materials structural changes or any requests for plan changes The Special Inspector is required to submit written reports to the City of Carlsbad building department of all work that he/she inspected and approved The final inspection approval will not be given until all Special Inspection reports have been received and approved by the City of Carlsbad building department Please submit the names of the inspectors who will perform the special inspections on each of the items indicated on the reverse side of this sheet (over) Carlsbad O5-4OO2 Decembers 20O5 SPECIAL INSPECTION PROGRAM ADDRESS OR LEGAL DESCRIPTION PLAN CHECK NUMBER OWNERS NAME I as the owner, or agent of the owner (contractors may not employ the special inspector) certify that I or the architect/engineer of record will be responsible for employing the special mspector(s) as required by Uniform Building Code (UBC) Section 1701 1 for the construction project located at the site listed above UBC Section 106 3 5 S'gned I as the engineer/architect of record certify that I have prepared the following special inspection, prognm as required by UBC Section 106 3 5 for the construction project located at the site listed above Signed 1 List of work requiring special inspection QLSolls Compliance Prior to Foundation Inspection [^Structural Concrete Over 2500 PSI Q Prestressed Concrete Qstructural Masonry f/TDesianer Specified /r^f^t^T f!:/2.tfm& /* J0T 2 Name(s) of >nHividual(s) or firm(s) responsible for the special inspections listed above B C Field Welding High Strength Bolting G/Expansion/Epoxy Anchors [vf Sprayed-On Fireproofing 1-1 Other 3 Duties of the special inspectors for the work listed above A. B C Special inspectors shall check in with the City and present th&r credentials tot approval onorto beginning work on the job site. Carlsbad 05-40O2 December 5, 20O5 VALUATION AND PLAN CHECK FEE JURISDICTION Carlsbad PREPARED BY Kurt Culver BUILDING ADDRESS 2753 Jefferson St BUILDING OCCUPANCY B/S-3 PLAN CHECK NO 05-4002 DATE December 5, 2005 TYPE OF CONSTRUCTION V-N BUILDING PORTION Office Garage Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code AREA (Sq Ft) 3093 3800 3093 6893 cb Valuation Multiplier 7538 3769 466 288 By Ordinance Reg Mod VALUE ($) 233150 143222 14413 19852 410,638 Bldg Permit Fee by Ordinance Plan Check Fee by Ordinance Type of Review I I Repetitive Fee Repeats Complete Review D Other i—I Hourly Structural Only Hour* Esgil Plan Review Fee $1,50444 $977 89 $842 49 Comments Sheet 1 of 1 macvalue doc City of Carlsbad &7S3 DATE BUILDING ADDRESS PROJECT DESCRIPTION ASSESSOR S PARCEL NUMBER W6;r;kis! BUILDING PLANCHECK CHECKLIST PLANCHECK NO |E'ih'ig in c e r i n g ^- ^ <&'* - 1)0 -fy (/EST VALUE ^ ENGINEERING DEPARTMENT APPROVAL The item you have submitted for review has been approved The approval is based on plans information and/or specifications provided in your submittal therefore any changes to these items after this date including field modifications must be reviewed by this office to insure continued conformance with applicable codes Please review carefully all comments attached as failure to comply with instructions in this report can result in suspension of permit to build D A Right of Way permit is required prior to construction of the following improvements DENIAL Please see._the attached report of deficiencies marked with D/ Make necessary corrections to plans or specifications for compliance with applicable codes and standards Submit corrected plans and/or specifications to this office for review By s^ / FOR OFFICIAL USE ONLY . Ejm^iNEERJNeTAUTHORIZATION TO ISSUE BUILDING PERMI] />*r^i/i^< .^/Date ATTACHMENTS D Dedication Application D Dedication Checklist HI Improvement Application D Improvement Checklist D Neighborhood Improvement Agreement D Grading Permit Application D Grading Submittal Checklist ED Right of Way Permit Application [] Right of Way Permit Submittal Checklist and Information Sheet ENGINEERING DEPT CONTACT PERSON Name _ Taniya Barrows _ City of Carlsbad Address 1635 Faraday Avenue Carlsbad CA 92008 Phone (760) 602 2773 _ CFD INFORMATION Parcel Map No Lots Recordation Carlsbad Tract A4 Carlsbad CA 920081-7314 • (76O) 6O2 2720 • FAX (760) BUILDING PLANCHECK CHECKLIST SITE £b f £- VlC/'\ ^-"vf" ~ J - ~ ~ . I PLAN - fo^d,1** qia«i a^ ?!^?lMr,?k«$ ptri!£?tmtg »f ^s,W Provide a fully dimensioned site plan drawn to scale Show v I«' I North Arrow Existing & Proposed Structures Existing Street Improvements Property Lines (show all dimensions) Easements 2 Show on site plan - F G H I Right-of-Way Width & Adjacent Streets Driveway widths Existing or proposed sewer lateral Existing or proposed water service Existing or proposed irrigation service A Drainage Patterns 1 Building pad surface drainage must maintain a minimum slope of one percent towards an adjoining street or an approved drainage course 2 ADD THE FOLLOWING NOTE Finish grade will provide a minimum positive drainage of 2% to swale 5 away from building B Existing & Proposed Slopes and Topography C Size type location alignment of existing or proposed sewer and water service (s) that serves the project Each unit requires a separate service however second dwelling units and apartment complexes are an exception D Sewer and water laterals should not be located within proposed driveways per standards 3 Include on title sheet A Site address B Assessor s Parcel Number C Legal Description For commercial/industrial buildings and tenant improvement projects include total building square footage with the square footage for each different use existing sewer permits showing square footage of different uses (manufacturing warehouse office etc) previously approved EXISTING PERMIT NUMBER DESCRIPTION Show all existing use of SF and new proposed use of SF Example Tenant Improvement for 3500 SF of warehouse to 3500 SF of office F \BUILDING PLANCHECK CKLST FORM doc iST iND BUILDING PLANCHECK CHECKLIST DISCRETIONARY APPROVAL COMPLIANCE 4a Project does not comply with the following Engineering Conditions of approval for Project No Gaodi-^Qns uj i M Y>e sAO.r D 4b All conditions are in compliance Date D D D DEDICATION REQUIREMENTS 5 Dedication for all street Rights-of-Way adjacent to the building site and any storm dram or utility easements on the building site is required for all new buildings and for remodels with a value at or exceeding $ 16.330 pursuant to Carlsbad Municipal Code Section 18 40 030 Dedication required as follows Dedication required Please have a registered Civil Engineer or Land Surveyor prepare the appropriate legal description together with an 8 % x 11 plat map and submit with a title report All easement documents must be approved and signed by owner(s) prior to issuance of Building Permit Attached please find an application form and submittal checklist for the dedication process Submit the completed application form with the required checklist items and fees to the Engineering Department in person Applications will not be accept by mail or fax Dedication completed by Date D D IMPROVEMENT REQUIREMENTS 6a All needed public improvements upon and adjacent to the building site must be constructed at time of building construction whenever the value of the construction exceeds $ 81.650 pursuant to Carlsbad Municipal Code Section 1840040 Public improvements required as follows Attached please find an application form and submittal checklist for the public improvement requirements A registered Civil Engineer must prepare the appropriate improvement plans and submit them together with the requirements on the attached checklist to the Engineering Department through a separate plan check process The completed application form and the requirements on the F BUILDING PLANCHECK CKLST FORM d BUILDING PLANCHECK CHECKLIST ,ST ,ND •vRD D D D D checklist must be submitted in person Applications by mail or fax are not accepted Improvement plans must be approved appropriate securities posted and fees paid prior to issuance of building permit Improvement Plans signed by Date 6b Construction of the public improvements may be deferred pursuant to Carlsbad Municipal Code Section 1840 Please submit a recent property title report or current grant deed on the property and processing fee of $ 400 00 so we may prepare the necessary Neighborhood Improvement Agreement This agreement must be signed notarized and approved by the City prior to issuance of a Building permit Future public improvements required as follows D 6c Enclosed please find your Neighborhood Improvement Agreement Please return agreement signed and notarized to the Engineering Department Neighborhood Improvement Agreement completed by Date 6d No Public Improvements required SPECIAL NOTE Damaged or defective improvements found adiacent to building site must be repaired to the satisfaction of the City Inspector prior to occupancy D D GRADING PERMIT REQUIREMENTS The conditions that invoke the need for a grading permit are found in Section 15J6 060 of the Municipal Code Inadequate information available on Site Plan to make a determination on grading requirements Include accurate grading quantities in cubic yards (cut fill import export and remedial) This information must be included on the plans / Grading Permit required A separate grading plan prepared by a registered Civil Engineer must be submitted together with the completed application form attached NOTE The Grading Permit must be issued and rough grading approval obtained prior to issuance of a Building Permit Grading Inspector sign off by Date 7c Partial Site Release from Engineering Inspector F BUILDING PLANCH6CK CKLST FORM d ST 1 D D D 2n ND RD3 D D D D D D BUILDING PLANCHECK CHECKLIST 7d Graded Pad Certification required (Note Pad certification may be required even if a grading permit is not required ) 7e No Grading Permit required 7f If grading is not required write No Grading on plot plan MISCELLANEOUS PERMITS 8 A RIGHT OF WAY PERMIT is required to do work in City Right-of-Way and/or private work adjacent to the public Right-of-Way Types of work include but are not limited to street improvements tree trimming driveway construction tying into public storm dram sewer and water utilities Right of Way permit required for D 9 INDUSTRIAL WASTE PERMIT If your facility is located in the City of Carlsbad sewer service area you need to contact the Carlsbad Municipal Water District, located at 5950 El Cammo Real Carlsbad CA 92008 District personnel can provide forms and assistance and will check to see if your business enterprise is on the EWA Exempt List You may telephone (760) 438 2722 extension 7153 for assistance Industrial Waste permit accepted by Date D D NPDES PERMIT 10a Storm Water Requirements Applicability Checklist Completed 10b Priority Determination and Compliance Priority Project a Subject to Standard Permanent Storm Water BMPs a Exempt 11 FEES a) Required fees are attached ~ a No fees required WATER METER REVIEW 10 > 12a Domestic (potable) Use Ensure that the meter proposed by the owner/developer is not oversized Oversized meters are inaccurate during low flow conditions If it is oversized for the life of the meter the City will not accurately bill the owner for the water used • All single family dwelling units received standard 1 service with 5/8 service F BUILDING PLANCHECK CKLST FORM d ,ST ,ND ,RD D D 12b BUILDING PLANCHECK CHECKLIST • If owner/developer proposes a size other than the standard then owner/developer must provide potable water demand calculations, which include total fixture counts and maximum water demand in gallons per minute (gpm) A typical fixture count and water demand worksheet is attached Once the gpm is provided check against the meter sizing schedule to verify the anticipated meter size for the unit • Maximum service and meter size is a 2 service with a 2 meter • If a developer is proposing a meter greater than 2 suggest the installation of multiple 2 services as needed to provide the anticipated demand (manifolds are considered on case by case basis to limit multiple trenching into the street) Irrigation Use (where recycled water is not available) All irrigation meters must be sized via irrigation calculations (in gpm) prior to approval The developer must provide these calculations Please follow these guidelines 1 If the project is a newer development (newer than 1998) check the recent improvement plans and observe if the new irrigation service is reflected on the improvement sheets If so at the water meter station the demand in gpm may be listed there Irrigation services are listed with a circled I and potable water is typically a circled W The irrigation service should look like STA1+00 Install 2 service and 5 meter (estimated 100 gpm) If the improvement plans do not list the irrigation meter and the service/meter will be installed via another instrument such as the building plans or grading plans (w/ a right of way permit of course) then the applicant must provide irrigation calculations for estimated worst case irrigation demand (largest zone with the farthest reach) Typically Larry Black has already reviewed this if landscape plans have been prepared but the applicant must provide the calculations to you for your use Once you have received a good example of irrigation calculations keep a set for your reference In general the calculations will include • Hydraulic grade line • Elevation at point of connection (POC) • Pressure at POC in pounds per square inch (PSI) • Worse case zone (largest farthest away from valve • Total Sprinkler heads listed (with gpm use per head) • Include a 10% residual pressure at point of connection In general all major sloped areas of a subdivision/project are to be irrigated via separate irrigation meters (unless the project is only SFD with no HOA) As long as the project is located within the City recycled water F BUILDING PLANCHECK CKLST FORM doc ,ST •>RD D D BUILDING PLANCHECK CHECKLIST service boundary the City intends on switching services/meters to a new recycled water line in the future 12c Irrigation Use (where recycled water is available) these irrigation 1 Recycled water meters are sized the same as the irrigation meter above 2 If a project fronts a street with recycled water then they should be connecting to this line to irrigate slopes within the development For subdivisions this should have been identified and implemented on the improvement plans Installing recycled water meters is a benefit for the applicant since they are exempt from paying the San Diego County Water Capacity fees However if they front a street which the recycled water is there but is not live (sometimes they are charged with potable water until recycled water is available) then the applicant must pay the San Diego Water Capacity Charge If within three years the recycled water line is charged with recycled water by CMWD then the applicant can apply for a refund to the San Diego County Water Authority (SDCWA) for a refund However let the applicant know that we cannot guarantee the refund and they must deal with the SDCWA for this Additional Comments F \BUILDING PLANCHECK CKLST FORM d D D ENGINEERING DEPARTMENT FEE CALCULATION WORKSHEET Estimate based on unconfirmed information from applicant Calculation based on building olancheck plan submittal Address Bldg Permit No Prepared EDUCA Types of Types of APT CAL Types of Types of by /L LCULATIONS Use /V7r Use ^ 17 Date List types 7ou .CULATIONS List Use CTBto Use 6?/j ands S S types and sc S S & q q q ]U q q 3//Dfc>Checked by jare footages for all uses Ft /Units ^>t>3 ~3 Ft are Ft Ft /Units EDU Date /<~TT- EDUs footages for all uses /Units 23Z^ ^> /Units ADTs ^ ~l— ADTs FEES REQUIRED WITHIN CFD D YES (no bridge & thoroughfare fee in District #1 reduced Traffic Impact Fee)DNO D 1 PARK IN LIEU FEE FEE/UNIT PARK AREA & # X NO UNITS D 2 TRAFFIC IMPACT FEE ADTs/UNITS D 3 BRIDGE AND THOROUGHFARE FEE (DIST #1 ADTs/UNITS D 4 FACILITIES MANAGEMENT FEE UNIT/SO FT D 5 SEWER FEE EDUs BENEFIT AREA EDUs D 6 SEWER LATERAL ($2 500) D 7 DRAINAGE FEES PLDA ACRES D 8 POTABL 1 of 2 F \FEE CALCULATION WORKSHEET doc Rev 7/14/00 ENGINEERING DEPARTMENT FEE CALCULATION WORKSHEET D 9 RECLAIMED WATER FEES UNITS CODE CONNECTION FEE METER FEE TOTAL OF ABOVE FEES* $ *NOTE This calculation sheet is NOT a complete list of all fees which may be due Dedications and Improvements may also be required with Building Permits \> V ' 2 of 2 F \FEE CALCULATION WORKSHEET doc Rev 7/14/00 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 DESIGN REVIEW BOARD RESOLUTION NO 298 A RESOLUTION OF THE DESIGN REVIEW BOARD OF THE CITY OF CARLSBAD, CALIFORNIA RECOMMENDING APPROVAL OF MAJOR REDEVELOPMENT PERMIT NUMBER RP 04-12, INCLUDING PARTICIPATION IN THE PARKING IN LIEU FEE PROGRAM FOR A MAXIMUM OF TWO PARKING SPACES, FOR THE CONSTRUCTION OF A 3 093 SQUARE FOOT COMMERCIAL OFFICE BUILDING ON PROPERTY LOCATED AT 2753 JEFFERSON STREET IN LAND USE DISTRICT 7 OF THE CARLSBAD VILLAGE REDEVELOPMENT AREA AND IN LOCAL FACILITIES MANAGEMENT ZONE 1 CASE NAME TUSCANY OFFICE SUITES APN 203-110 14 CASE NO RP04 12 WHEREAS, Bart M Smith, Applicant has filed a verified application with the Redevelopment Agency of the City of Carlsbad regarding property owned by Bill Daly, Owner , described as Assessor Parcel Number 203-110-14, and more thoroughly described in Attachment A (the Property*) and WHEREAS said application constitutes a request for a Major Redevelopment Permit as 1 shown on Exhibits "A-H" dated April 18, 2005, on file in the Housing and Redevelopment Department "Tuscany Office Suites RP 04-12" as provided by Chapter 21 35 080 of the Carlsbad Municipal Code, and WHEREAS the Design Review Board did on the 18th day of April 2005 hold a duly noticed public hearing as prescribed by law to consider said request and WHEREAS at said public hearing, upon hearing and considering all testimony and arguments if any of persons desiring to be heard said Board considered all factors relating to "Tuscany Office Suites RP 04-12" NOW THEREFORE BE IT HEREBY RESOLVED by the Design Review Board as follows A That the foregoing recitations are true and correct 8 10 11 12 ia 28 General 7 1 Prior to hauling dirt or construction materials to or from any proposed construction site within this project, Developer shall apply for and obtain approval from the City Engineer for the proposed haul route 9 2 Prior to occupancy Developer shall install ram gutters to convey roof drainage to an existing residential use ENGINEERING CONDITIONS Note Unless specifically stated in the condition all of the following conditions upon the approval of this proposed redevelopment must be met prior to approval of a building or grading permit whichever occurs first approved drainage course or street to the satisfaction of the City Engineer Fees/Agreements Developer shall cause property owner to execute and submit to the City Engineer for recorjdation the City s standard form Drainage Hold Harmless Agreement regarding ^drainage across the adjacent property 14 Pnor to approval of any grading or building permits for this project Developer shall cause Owner to give written consent to the City Engineer to the annexation of the area shown within the boundaries of the property into the existing City of Carlsbad Street Lighting and Landscaping District No 1 and/or to the formation or annexation into an additional Street Lighting and Landscaping District Said written consent shall be on a form provided by the City Engineer Grading 16 17 18 19 S" Based upon a review of the proposed grading shown on the site plan a grading permit for ' this project is required Developer shall apply for and obtain a grading permit from the 21 " 22 23 . Elimination System (NPDES) permit Developer shall provide improvements constructed pursuant to best management practices as referenced in the "California Storm Water Best Management Practices Handbook" to reduce surface pollutants to an acceptable level prior to discharge to sensitive areas Plans for such improvements shall be submitted to and subject to the approval of the City Engineer Said plans shall include but not be City Engineer prior to issuance of a building permit for the project ^Dedications/Improvements Developer shall comply with the Citys requirements of the National Pollutant Discharge 25 26.. limited to notifying prospective owners and tenants of the following 27 DRBRESONO 298 7- 1 2 3 4 5 6 7 8 9 10 12 13 14 15 16 17 18 19 23 X 24 25 26 27 28 All owners and tenants shall coordinate efforts to establish or work with established disposal programs to remove and properly dispose of toxic and hazardous waste products Toxic chemicals or hydrocarbon compounds such as gasoline motor oil antifreeze, solvents, paints, paint thmners, wood preservatives and other such fluids shall not be discharged into any street public or private, or into storm dram or storm water conveyance systems Use and disposal of pesticides fungicides herbicides, insecticides fertilizers and other such chemical treatments shall meet ederal State, County and City requirements as prescribed in their respective containers anagement Practices shall be used to eliminate or reduce surface pollutants planning any changes to the landscaping and surface improvements Pnor to building permit or grading permit issuance whichever occurs first Developer shall have design, apply for and obtain approval of the City Engineer for the structural section for the access aisles with a traffic index of 5 0 in accordance with City Standards due to truck access through the parking area and/or aisles with an ADT greater than 500 The structural pavement design of the aisle ways shall be submitted together with required R value soil test information and approved by the City Engineer as part of the building or grading plan review whichever occurs first Special Conditions The Average Daily Trips (ADT) and floor area contained in the staff report and shown on the site plan are for planning purposes only Developer shall pay traffic impact and sewer impact fees based on Section 18 42 and Section 13 10 of the City of Carlsbad Municipal Code, respectively rlsbad Municipal Water Distnct The final approved site plan shall be revised to show the fire service pipe to be 6 inches in diameter In addition, the double detector check valve shall be located on private property as required per City Standard W-22 fO Pnor to approval of improvement plans or final map Developer shall meet with the Fire Marshal to determine if fire protection measures (fire flows fire hydrant locations building sprinklers) are required to serve the project Fire hydrants if proposed shall be considered public improvements and shall be served by public water mains to the sfaction of the Distnct Engineer Pnor to issuance of building permits Developer shall pay all fees deposits, and charges for connection to public facilities Developer shall pay the San Diego County Water Authonty capacity charge(s) pnor to issuance of Building Permits DRBRESONO 298 8- 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 12 Developer shall install potable water services and meters at a location approved by the District Engineer The locations of said services shall be reflected on public irovement plans The Developer shall install sewer laterals and clean-outs at a location approved by the District Engineer The locations of sewer laterals shall be reflected on public improvement plans The Developer shall design and construct public water, sewer, and recycled water facilities substantially as shown on the Site Plan to the satisfaction of the District Engineer Proposed public facilities shall be reflected on public improvement plans This project is approved upon the express condition that building permits will not be issued for the development of the subject property, unless the District Engineer has determined that adequate water and sewer facilities are available at the time of occupancy STANDARD CODE REMINDERS The project is subject to all applicable provisions of local ordinances, including but not limited to the following code requirements 1 Developer shall pay the citywide Public Facilities Fee imposed by City Council Policy #17, the License Tax on new construction imposed by Carlsbad Municipal Code Section 5 09 030, and CFD #1 special tax (if applicable) subject to any credits authorized by Carlsbad Municipal Code Section 5 09 040 Developer shall also pay any applicable Local Facilities Management Plan fee for Zone 1, pursuant to Chapter 21 90 All such taxes/fees shall be paid at issuance of building permit If the taxes/fees and not paid this approval will not be consistent with the General Plan and shall become void 2 The Developer shall pay a landscape plan check and inspection fee as required by Section 20 08 050 of the Carlsbad Municipal Code General 3 This approval shall become null and void if building permits are not issued for this project within 18 months from the date of final project approval 4 Approval of this request shall not excuse compliance with all applicable sections of the Zoning Ordinance and all other applicable City ordinances in effect at time of building permit issuance, except as otherwise specifically provided herein 5 The project shall comply with the latest non residential disabled access requirements pursuant to Title 24 of the State Building Code Engineering 6 Developer shall exercise special care during the construction phase of this project to DRBRESONO298 9- prevent offsite siltation Planting and erosion control shall be provided in accordance 2 with Carlsbad Municipal Code Chapter 1516 (the Grading Ordinance) to the satisfaction of the City Engineer 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 DRBRESONO 298 10- 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 NOTICE Please take NOTICE that approval of your project includes the "imposition of fees dedications, reservations, or other exactions hereafter collectively referred to for convenience as "fees/exactions " You have 90 days from the date of final approval to protest imposition of these fees/exactions If you protest them, you must follow the protest procedure set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3 32 030 Failure to timely follow that procedure will bar any subsequent legal action to attack, review set aside void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity charges, nor planning, zoning, grading or other similar application processing or service fees in connection with this project, NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired. PASSED, APPROVED, AND ADOPTED at a regular meeting of the Design Review Board of the City of Carlsbad, California, held on the 18* day of April 2005 by the following vote to wit AYES NOES ABSENT ABSTAIN HEINEMAN, BAKER, LAWSON AND MARQUEZ NONE NONE NONE COURTNEY HEJNJMANLCH)kffiJ?ERSON DESIGN REVIEW BOARD ATTEST DEBBIE FOUNTAIN HOUSING AND REDEVELOPMENT DIRECTOR DRBRESONO 298 11- MAR-06-2007 TUE 07 25 AM ENGINSPECTION FAX 7604384178 PROJECT INSPECTOR, PROJECT |[ CITY OF CARLSBAD GRADING INSPECTION CHECKLIST FOR PARTIAL SITE RELEASE DATE.7 .GRADING PERMIT NQ.£>Po LOTS REQUESTED FOR RELEASE N/A = NOT APPLICABLE 1* COMPLETE 0 = Incomplete, or unacceptable Site access to requested lots adequate and logically grouped Site erosion control measures adequate Overall site adequate for health safety and welfare of public Letter from Owner/Dev requesting partial release of specific lots pads orbldg 8%" x 11" site plan (attachment) showing requested lots submitted Compaction report from soils engineer submitted (If soils report has been submitted with a previous partial release a letter from soils engineer referencing the soils report and identifying specific lots for release shall accompany subsequent partial releases) EOW certification of work done with finish pad elevations of specific lots to be released Letter must state lot (s) is graded to within a tenth (1) of the approved grading plan Geologic engineer's letter if unusual geologic or subsurface conditions exist Fully functional fire hydrants within 500 feet of building combustibles and an ail weather roads access to site is required •—L^-partal release of grading for the above stated lots is approved for the purpose of building ^ permit issuance Issuance of building permits is still subject to all normal Cfty requirements required pursuant to the building permit process 1st s ^~ ,- — ,-~" — " ^ _**•" i* ^ ^ ?nd -- ^— — - ' -Partial permit » 1 2 3 4 5 6 7 8 9 rele ISSl D Partial release of the site is denied for the following reasons Project Inspector Date Manager Date File Edit View Image Go To Favorites Help JSearch }, Favorites ©' s^ •* O u fi 5] & Address €(http //docweb/idmws/doccontentdlPlibrary=Car|sbadADocman&id=003968462 1 Link.. <fidWhoYaGonnaCall «fiAM Best Home Page The Insurance Infoimation Source .fl An notation Test OfJ for Help press Fl .'&&£ti& lj^>oa^S^^|'^S3>f ••<'.'/'''1<'"»*-<s<#*, 1 UNLESS NOTED OTHERWISE PRIVATE STORU DRAIN i SOW WALL PVC (SDP-35 WN) 9 \X UN SLOPE SO 9 SITES. DUE TO EXISTING GRADES AND SOIL ENGINEER RECOUi 1 CONCRETE SIDEWALKS SHALL NOT BE LESS THAN 4 CLEAN SAND WTH A UWUW REINFORCEMENT OF S»6_ mE UESH MINTS AND REINFORCEMENTS PER SOI E 4 BOUNDARY INFORUATW CALCULATED PER UAP NO SURVEY NO. 9217 AND GRANT DEED RECORDED tO/1/ NO 2003-1207338, OF OR 5 SEE SHEET 3 AND 4 FOR EROSION CONTROL UEASl CONSTRUCTION BEST MANAGEMENT PRACTICES. S PRIVATE STORU DRAIN DRAINAGE SWALES, AND 8V MAINTAINED BY THE PROPERTY OWER 7 A PRELMNARY TITLE REPORT PREPARED BY FIRST INSURANCE COMPANY AS ORDER NO D/V-IW2320, Di 2005, WAS PROmD BY THE OWR AND REVIEWED EASEMENTS. NO EASEMENTS HOT REVEALED BY SAID 8. ALL ROOF PRAINiW& SHALL BC TO J£fFffR$0tf STREET D 9 X9 PRIVATE CATCH BASIN iTH ATRIUU GRATE APPROVED EQUAL Unknown Zone November 13 2007 TO Building Department FROM Assistant Planner Housing and Redevelopment Tuscany Suites Office Building - RP04 12 (Plan Check No CB06330) I have completed the second plan check for the above referenced project The Housing and Redevelopment Commission approved this project on June 14 2005 The applicant has met all conditions and the Housing and Redevelopment department can support the issuance of the building permit for the above referenced project AUSTIN SILVA C Bart Smith Architect D D D D PLANNING DEPARTMENT BUILDING PLAN CHECK REVIEW CHECKLIST Plan Check No CB Planner CLIFF JONES APN Address Phone (760) 434-2813 Type of Project & Use Zoning S/1-|iUfitl7)General Plan CFD (in/out) #_Date of participation -^IfllY QtflCJ Wet Project Density DU/AC V Facilities Management Zone \_ Remaining net dev acres Circle One (For non residential development Type of land used created by this permit ) Legend ^ Item Complete CD Item Incomplete Needs your action Environmental Review Required YES NO ~^ TYPE DATE OF COMPLETION Compliance with conditions of approval7 If not state conditions which require action Conditions of Approval S £•£ Discretionary Action Required APPROVAL/RESO NO P?-g # 7^8 PROJECT NO YES "><^ NO DATE TYPE fej7 /DM OTHER RELATED CASES Compliance with conditions or approval7 If not state conditions which require action Conditions of Approval its) D NOX Coastal Zone Assessment/Compliance Project site located in Coastal Zone7 YES_ CA Coastal Commission Authority7 YES_ If California Coastal Commission Authority Contact them at - 7575 Metropolitan Drive Suite 103 San Diego CA 921084402 (619)7672370 Determine status (Coastal Permit Required or Exempt) Coastal Permit Determination Form already completed7 YES_ If NO complete Coastal Permit Determination Form now Coastal Permit Determination Log # D D Follow Up Actions 1) Stamp Building Plans as Exempt or Coastal Permit Required (at minimum Floor Plans) 2) Complete Coastal Permit Determination Log as needed Inclusionary Housing Fee required YES NO X, (Effective date of Inclusionary Housing Ordinance May 21 1993) Data Entry Completed7 YES NO (A/P/Ds Activity Maintenance enter CB# toolbar Screens Housing Fees Construct Housing Y/N Enter Fee UPDATE') H \ADMIN\COUNTER\BldgPlnchkRevChklst Rev 9/01 CD Site Plan * 1 Provide a fully dimensional site plan drawn to scale Show North arrow prope^y lines easements existing and proposed structures streets existing street improvements right of way width dimensional setbacks and existing topographical lines (including all side and rear yard slopes) 2 Provide legal description of property and assessor s parcel number ^ D D D D n n n n Policy 44 - Neighborhood Architectural Design Guidelines n n n n n n n D 1 AppliCc 2 Project Zoning 1 Setbac Front Interior Street Rear Top of 2 Access Front Interior Street i Rear Structu jbihty YES >£ complies YES ^ ks Side Side slope NO - NO Required ' Required Required Required Required r- :> Shown S C^ Shown 6> C, Shown £, £> Shown £> ±/J\ Shown ory structure setbacks Required K)/A Shown NJ/A Side Bide re separation Required Required Required ^ Required Shown Shown , Shown " ~ Shown \/ 3 Lot Coverage 4 Height 5 Parking Required Required Spaces Required Shown Shown Shown 72-'/' (breakdown by uses for commercial and industrial projects required) Residential Guest Spaces Required (Q Shown Additional Comments AVI (A - L ttca.C& "S 4-U/J- jp^rh^p •oy 4-W f tflrt - OK TO ISSUE AND ENTERED APPROVAL INTO COMPUTER DATE H \ADMIN\COUNTER\BldgPlnchkRevChklst Rev 9/01 Septembers 2006 TO Building Department FROM Cliff Jones Housing and Redevelopment Tuscany Suites Office Building - RP04-12 (Plan Check No CB054002) I have completed the second plan check for the above referenced project The Housing and Redevelopment Commission approved this project on June 14 2005 The following conditions of approval must be satisfied prior to the issuance of the building permit 1 Prior to issuance of the building permit the Developer shall enter into a Parking In-Lieu Fee Participation Agreement and pay the established Parking In-Lieu Fee for two (2) parking spaces The fee shall be the sum total of the fee per parking space in effect at the time of the building permit issuance times the number of parking spaces needed to satisfy the project s parking requirement (2 spaces total) The current fee is $11 240 per space Roxanne Muhlmeister in the City of Carlsbad Finance Department will collect the fee Please contact Roxanne with any questions that you may have regarding payment at 760-602-2475 CLIFF JONES C Bart Smith Architect June8 2006 TO Building Department FROM Cliff Jones Housing and Redevelopment Tuscany Suites Office Building - RP04-12 (Plan Check No CB054002) I have completed the second plan check for the above referenced project The Housing and Redevelopment Commission approved this project on June 14 2005 The following conditions of approval must be satisfied prior to the issuance of the building permit 1 The Developer shall obtain Planning Director approval of a Final Landscape and Irrigation Plan showing conformance with the approved Preliminary Landscape Plan and the Citys Landscape Manual The Developer shall construct and install all landscaping as shown on the approved Final Plans and maintain all landscaping in a healthy and thriving condition free from weeds trash and debris 2 Prior to issuance of the building permit the Developer shall enter into a Parking In-Lieu Fee Participation Agreement and pay the established Parking In-Lieu Fee for two (2) parking spaces The fee shall be the sum total of the fee per parking space in effect at the time of the building permit issuance times the number of parking spaces needed to satisfy the project s parking requirement (2 spaces total) Additionally applicant needs to make a note on the plans that signage needs to be provided identifying the compact parking spaces CLIFF JONES C Bart M Smith Applicant Carlsbad F.re Department Plan Review Requirements Category COMMIND , INDUST Date of Report 06 06 2006 Reviewed by Name Address Permit # CB054002 Job Name TUSCANY OFFICE BLDG 3093 SF Job Address 2753 JEFFERSON ST CBAD The item you have submitted for review is incomplete At this time, this office cannot adequately conduct a review to determine compliance with the applicable codes and/or standards Please review carefully all comments attached Please resubmit the necessary plans and/or specifications with changes "clouded" to this office for review and approval Conditions Cond CON0000953 Show building location for street address on page A 7 Note on plans that sprinkler riser room will be labeled location of fire extinguishers on plans Fire extinguishers shall be type 2A 10BC and spaced at maximum 75 ft intervals S 3 occupancy classification on plans on plans that sprinkler waterflow will be monitored exit signs and battenes will have an exterior rating ^ Knox box will be located at the front of the building Entry 11/28/2005 By pp Action CO Cond COM [MET] ^PPROVED^THIS PROJECT HAS BEEN REVIEWED AND APPK^ LLI I1 TO THE PURPOSES OF ISSUANCE OF BUILDING PERMIT THIS APPROVAL IS SUBJECT TO FIELD INSPECTION AND REQUIRED TEST, NOTATIONS HEREON, CONDITIONS IN CORRESPONDENCE AND CONFORMANCE WITH ALL APPLICABLE REGULATIONS THIS APPROVAL SHALL NOT BE HELD TO PERMIT OR APPROVE THE VIOLATION OF ANY LAW Carlsbad Fire Department Plan Review Requirements Category COMMIND , INDUS! Date of Report 11 28 2005 Reviewed by Name SMITH BART Address 682 2ND ST ENCINITAS CA 92024 Permit # CB054002 Job Name TUSCANY OFFICE BLDG 3093 SF Job Address 2753 JEFFERSON ST CBAD INCOMPLETE The item you have submitted for review is incomplete At this time this office cannot adequately conduct a review to determine compliance with the applicable codes and/or standards Please review carefully all comments attached Please resubmit the necessary plans and/or specifications with changes "clouded" to this office for review and approval Conditions Cond CON0000953 1 Show building location for street address on page A 7 2 Note on plans that sprinkler riser room will be labeled 3 Show location of fire extinguishers on plans Fire extinguishers shall be type 2 A 10BC and spaced at maximum 75 ft intervals 4 Show S-3 occupancy classification on plans 5 Note on plans that sprinkler waterflow will be monitored 6 Exterior exit signs and batteries will have an exterior rating 7 Knox box will be located at the front of the building Entry 11/28/2005 By pp Action CO GORDON ENGINEERING GROUP INC January 23 2006 Mr BartM Smith AIA DZN Partners 628 Second Street Encmitas CA 92024 Project Tuscany Office Suites - Plan Check Number 05 4002 Job Number 12000 We have completed our review for substantial conformance of the Tuscany Office Suites roof truss calculations package prepared by Stone Truss Company Please keep in mind our review is for substantial conformance to the project documents and truss design and truss to truss connection design remains the responsibility of the truss designer The truss calculation package appears to be in substantial conformance with the project documents with the exception of the following items • Trusses B B1 B2 B3 B4 and BB will be three point bearing The interior bearing point will be at the wall between Suite 4 and the walkway/breezeway Please reference the legend showing bearing and non bearing walls on Sheet S213 for clarification SI Z Please have the truss designer revise the truss calculation package for the items noted above It is not necessary for the revised truss calculations to be re submitted to Gordon Engineering Group Inc If you have any questions please do not hesitate to contact us (760) 787 0506 Sincerely GORDON ENGINEERING GROUP INC X Signature Alexander Gordon P E President Date 26163 MAT LIN ROAD RAMONA CA 92O65 PH 76O 787 O5O6 10F 1 City of Carlsbad • uilding Department CERTIFICATE OF COMPLIANCE PAYMENT OF SCHOOL FEES OR OTHER MITIGATION This form must be completed by the City the applicant and the appropriate school districts and returned to the City prior to issuing a building permit The City will not issue any building permit without a completed school fee form Project Name Building Permit Plan Check Number Project Address APN Project Applicant (Owner Name) Project Description Building Type Residential Second Dwelling Unit Residential Additions \ Commercial/Industrial City Certification of Applicant Information Tuscany Office Building CB063330 2753 Jefferson St 203-110-14-00 Bill Daly 2 story office building COMM New Dwelling Unit(s) Square Feet of Living Area in New Dwelling Square Feet of Living Area in SOU Net Square Feet New Area 3093 Square Feet Floor Area Date 5I? I0-7 SCHOOL DISTRICTS WITHIN THE CITY OF CARLSBAD Carlsbad Unified School District 6225 El Cammo Real Carlsbad CA 92009 (331 5000) Vista Unified School District 1234 Arcadia Drive Vista CA 92083 (7262170) San Marcos Unified School District 215MataWay San Marcos CA 92069 (290 2649) Contact Nancy Dolce (By Appt Only) Encmitas Union School District 101 South Rancho Santa Fe Rd Encmitas CA 92024 (944 4300 ext 166) San Dieguito Union High School District 710 Encmitas Blvd Encmitas CA 92024 (753 6491) Certification of Applicant/Owners The person executing this declaration ( Owner1) certifies under penalty of perjury that (1) the information provided above is correct and true to the best of the Owner's knowledge and that the Owner will file an amended certification of payment and pay the additional fee if Owner requests an increase in the number of dwelling units or square footage after the building permit is issued or if the initial determination of units or square footage is found to be incorrect and that (2) the Owner is the owner/developer of the above described project(s) or that the person executing this declaration is authorized to sign on behalf of the Owner Signature Date Revised 3/30/2006 SCHOOL DISTRICT SCHOOL FEE CERTIFICATION (To be completed by the school distnct(s))************************************************* THIS FORM INDICATES THAT THE SCHOOL DISTRICT REQUIREMENTS FOR THE PROJECT HAVE BEEN OR WILL BE SATISFIED SCHOOL DISTRICT The undersigned being duly authorized by the applicable School District certifies that the developer builder or owner has satisfied the obligation for school facilities This is to certify that the applicant listed on page 1 has paid all amounts or completed other applicable school mitigation determined by the School District The City may issue building permits for this project SIGNATURE OF AUTHORIZED SCHOOL DISTRICT OFFICIAL TITLE NAME OF SCHOOL DISTRICT DATE PHONE NUMBER Revised 3/30/2006 Rpr 24 06 05 37p Bart M Smith (760] 753-0600 p 1 Oty of Carlsbad Plumbing Electrical - Mechanical Worksheet Project Address 2753 JEFFERSON ST Permit No CBo5too2 Questions below refer to work being done for this permit only Plumbine « Number of new or relocated fixtures traps or floor drains? * New building sewer line? » Number of roof drains? * Install/alter water line? * Number of water heaters? ^TMlKLB&S * Number of hose bibs? * Gas piping system - * Number of new or relocated gas outlets * New water meter - Yes * No _ Yes «/ No Install / No of Potable Irrigation Repair Size E/ectnca/ » Number of new panels or subpanels? Size of New Service Size* Single Phase D * Three Phase pj. * Three Phase-480 * Remodel (relocate existing outlets/switches or add outlets/switches Mechanical » Number of furnaces A/C or heat pumps? * Number of fireplaces? * Number of exhaust fans? (5 PATH •*• \ * Number of exhaust hoods? * Number of boilers or compressors? * New or relocated duct work? Number of amperes Number of amperes N umber of amperes Yes _ No AP-6A 0 Number of HP? Yes No BEFORE THE PERMIT CAN BE FEE'D OUT THIS FORM NEEDS TO BE RETURNED TO THE BUILDING DEPARTMENT - FAX NUMBER (760) 602-8558 S ol/>in o>>o if» ~