HomeMy WebLinkAbout2760 GATEWAY RD; ; CB130377; Permit05-23-2013 City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Commercial/Industrial Permit Permit No Building Inspection Request Line (760) 602-2725 CB130377 Job Address Permit Type Parcel No Valuation Occupancy Group Project Title 2760 GATEWAY RD CBAD Tl Sub Type COMM 2133000100 Lot# 0 $23,980 00 Construction Type NEW Reference # TORREY PINES BANK- 646 SF REMODEL BANK TO BANK Status Applied Entered By Plan Approved Issued Inspect Area Plan Check # ISSUED 02/14/2013 SKS 05/23/2013 05/23/2013 Applicant ANNE SNEED ARCHITECTURAL INTERIORS Owner TORREY PINES BANK 4757 SUN VALLEY RD DEL MAR CA 92014 858-356-9212 12220 EL CAMINO REAL SAN DIEGO CA 92130 Building Permit $264 07 Meter Size Add'l Building Permit Fee $0 00 Add'l Reel Water Con Fee $0 00 Plan Check $184 85 Meter Fee $0 00 Add'l Building Permit Fee $0 00 SDCWA Fee $0 00 Plan Check Discount $0 00 CFD Payoff Fee $0 00 Strong Motion Fee $5 04 PFF (3105540) $0 00 Park Fee $0 00 PFF (4305540) $0 00 LFM Fee $0 00 License Tax (3104193) $0 00 Bndge Fee $0 00 License Tax (4304193) $0 00 BTD #2 Fee $0 00 Traffic Impact Fee (3105541) $0 00 BTD #3 Fee $0 00 Traffic Impact Fee (4305541) $0 00 Renewal Fee $0 00 PLUMBING TOTAL $0 00 Add'l Renewal Fee $0 00 ELECTRICAL TOTAL $41 00 Other Building Fee $0 00 MECHANICAL TOTAL $0 00 Pot Water Con Fee $0 00 Master Drainage Fee $0 00 Meter Size Sewer Fee $0 00 Add'l Pot Water Con Fee $0 00 Redev Parking Fee $0 00 Red Water Con Fee $0 00 Additional Fees $0 00 Green BIdg Stands (SB1473) Fee $1 00 HMP Fee 9? Fire Expedidted Plan Review $0 00 Green BIdg Standards Plan Chk 99 TOTAL PERMIT FEES $495 96 Total Fees $495 96 Total Payments To Date $495 96 Balance Due-$0 00 Inspector FINAL APPROVAL Date -OL Clearance NOTICE Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exactions" You have 90 days from the date this permit was issued to protest imposition of these fees/exactions If you protest them, you must follow the protest procedures set forth in Government Code Section 56020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3 32 030 Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project NOR DOES IT APPLY to any fees/exactions of which vou have previously been given a NOTICE similar to this, or as to which the statute of limitations tias previously othenwise expired THE FOLLOWING APPROVALS REQUIRED PRIOR TO PERMrr ISSUANCE LAWWING }<dNGINE£RING "^H^l HIDING IRE DHEALTH jHAZMAT/APCO CITY OF CARLSBAD Building Permit Application 1635 Faraday Ave , Carlsbad, CA 92008 Ph 760-602-2719 Fax 760-602-8558 email building@carlsbadca gov www carlsbadca gov Plan CheckNo.(^(33 (^OS^H Est. Value ^ 3, ^ Plan Ck. Deposit / Sj^ Date ('^(f:^ jswPPP ^^'---^ SUITE»/SPACE#/UNrr« IVS -OS -00 • CT/PRCUECT« LOT* PHASt # OF UNfTS # BEDROOMS # BATHROOMS TENANT BUSINESS NAME CONSTR TVPE OCC GROUP DESCRIPTION OF WORK Include Square Feet of Aftecteil Area(s) ' ' I ' EXISTING USE , . , PROPOSED USE . , GARAGE (SF) PATIOS (SF) 3ECKS ISr) FIREPLACE AIR CONDITIONING FIRE SPRINKLERS VEsOs N(^_YES^NOn YESriNOf^ ADDRESS crrv ' , . STATE/ ZIP _ . , crrv STATE ZIP AX * PHONE FAX EMAIL PROPERty'OWNER NAME ADDRESS CriY STATE ZIP CITY _ V-.^ STATE A ' ZIP A " irt PHONE F AX EMAIL ARCtVDESIGNER NAME & ADDRESS STATE LIC # CLASS ^ CITY BUS Lies . ^ /3 lZOO(bZ^ (Sec 70315 Business t., . —, -j ..... ., r- , >. applicant for such pemiit to file a signed statement that he is licensed pursuant to the provisions of the Contractor s Uc Business and Professions Code) or that he is exempt therefrom, and the basis for the alleged exemption Any violation c civil penalty of not more than five hundred dollars fSSOO)) Its issuance aiso requires tne h Section 7000 of Division 3 of the 3 permit subjects the applicant to a WoHiere' Compensation Declaration / nereby sBm under pensHy ol perjury one of the tollomng declsralicns Bl have and will maintain a certificate of consent to self-insure lor wotters compensalion as provided Ijy Sednn 3700 of Ihe Labor Code, lor Ihe performance of Ihe woitc for whicn this pemiil is issued I have and will maintain workers' compensation as neouired bv Section 3700 of the Labor Code lor Ihe peitottnance of Ihe woi* for which this geriral is issued My workers' compensabon insurance earner and policy number are i,i..,r.n., Tl^VO-V'^i^ WOf '^ - p<*cyNo Jt/& ^ 3 & % ^ ExplratonDate ^-O?' 7^0) Bsection need not be completed il the permit is for one hundred dollars {S100) or less Certificate of Exemption I certify thai in Ihe perfonnance of the work for which Ihis pemiit is issued, I shall nol employ any person in any manner so as to became subject b the Workers' Compensalon Laws o( California WARNING Failure to secure workers'compensation cwera^s unlawful, and shall subject an employer to criminal penalties and chrll fines up to one hundred thousand dollars {&1OO,O00), in addition to the cost of compensation, damages as pnwided loOi<^MIaamOi of the Labor code, interest and attorney's fees jfif CONTRACTOR SIGNATURE ^jU C(M /y^^//w\/ • AGENT DATE /• 2' 0 ) S, / hereby sfflrm (fiat / sm exempi fom ConSaofors License Law for (fie tallamng reason. I I I, as owner of the pmoecty ot ray employees with wages as their sole compensalon will do the work and the stmcture is not Intended or offered for sale (Sec 7044, Business and Professions Coie The Contractor's License Law does nol apply lo an owner o( property who builds or Imp.oves thereon and who does such worit himself or through his own employees, provided that such improvements are nol intended or offered for sale If howeve., Ihe buioing or imp.'ovemenl is sold within one year of completion Ihe owner-builder will have the burden of proving that he did not build or improve for the purpose of sale) I I I as owner of the property, am exdusnrely contracting wilh licensed contradore to constnid the project (Sea 7044, Business and Professions Oxie The Contractor s License Law does nol apply to an owner of property who builds or improves ftereon, and contracts for such (sojeds with conlrador(s) licensed pursuant to the Conlrador's License Law). I ) I am exempt under Section Business and Professions Code for this reason 1 I personally plan to provide the major labor and matenals for conslnjction of (he proposed p'opeityimprovemenL f~TYes I Ko 2 I (have / have not) sgned an application for a building perniit for Ihe proposed work. 3 I have contracted with the following person (firm) to provide the proposed constmction (mdude name address / phone / contractors license number) 4 I plan lo provide portions of Ihe work, but I have hired Ihe following person to coordinate, supervise and provide the major work (indude name / address / phone / contradots license number) 5 I 'fl! provide some of the work, bul I have contracted (hired) the folowing persons to p,-ovid6 the work indicated (indude name / address / phone / type of work) ^gS'PROPERTY OWNER SIGNATURE •AGENT DATE Is Ihe applicant or fuhiie building occupant required to submit a business olaivacutely hazardous matenals registration form or nsk manEgement and prevention program under Sections 25505,25533 or 25534 of the Piesley-Tanner Hazardous Substance Account AcP Yes ^ Is the applicani or fuluns building occupant required lo obtain a perniit from the air pollution control distnct or air qua|i^ management distnd' Yes /ra Islhefacility to be constructed within 1,000 feet ot Ihe outer boundary of a school site'' Yes Aid v_/ IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT I hereby afRrm that there is a Lender's Name N j jmstruction lending agency for the performance of the work this pemiit is issued (Sec 3097 (i) Civil Code) Lender's Address Iceftifythatlhaveieadtheapplicabonandsfateffiatfheaboveinfbnnationisooiiedandtliattheinfbtiiiabonontheplans^ lagieetocomply with allO^onlinancesand State laws telatingtobuildingconstruction I hereby authonze representative of the City of Carlsbad ID enter upon the above mentioned pnsperty for inspection purposes I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CAFiLSBAD AGAINST ALL UABIUTIES, JUDGMENTS, COSTS ANO EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GFiANTING OF THIS PERMIT CSaiA. An OSHA perm* B required ^ excavatais over Sff de^ and danditon rss constmction of stnictures over 3 stones in heighL EXFf^ATICMJ Every p»mt issued by the BuMing OffcalAJitffijihe provisiCBis of this Ctode shall expire by limitation and tjecome null and vod if the tulding or work authonzed t)y sudi pemiit is not commenced wthn IS) days tam Ihe dale of such permit or if thebuMin^ttfwMk fHifm^ by such pemiit is suspended or abandoned at any time after the work is commenced for a penod of 180 days (Section 106 4 4 Uniform Building Code) >€!f APPLICANT'S SIGNATURE DATE STOP: THIS SECTION NOT REQUIRED FOR BUILDING PERMIT ISSUANCE. Complete the following ONLY if a Certificate of Occupancy will be requested at final inspection. CEBTIFICATE OF OCCUPANCY f C o m m e r c i a I Pro/ects Only) Fax (760) 602-8560, Email buildingtScarlsbadca gov or Mail the completed forni to City of Carlsbad, Building Division 1635 Faraday Avenue, Carisbad, California 92008 00#: (Office Use Only) CONTACT NAME OCCUPANT NAME , . . . / 1II.D>ING ADDRESS' ~ STATE BUILDINl ZIP CITY STATE I ZIP Carlsbad CA PHONE FAX EMAIL OCCUPANT'S BUS LIC No imJVBIYOPnO PICKUP. CO|\rrACT(Usted above)' OCCUPANT (Usted above) CONTFJACTOR (On Pg 1) MAIL TO OgljTAfrTfi ijjffid ahru^ OCCUPAI>tT (Listed above) CONTRACTOR (On Pg 1) ASSOCIATED CB#~ IVIAIL/FAX TO OTHER NO CHANGE IN USE / NO CONSTRUCTION CHANGE OF USE / NO CONSTRUCTION DATE Inspection List Permits CB130377 Type Tl Date Inspection Item 01/22/2014 89 Final Combo 01/22/2014 89 Final Combo 12/12/2013 89 Final Combo 10/11/2013 85 T-Bar 10/03/2013 17 Intenor Lath/Drywall 10/02/2013 17 Interior Lath/Drywall 10/01/2013 17 Interior Lath/Drywall 10/01/2013 84 Rough Combo 09/25/2013 84 Rough Combo 09/05/2013 14 Frame/Steel/Bolting/Weldin 09/05/2013 34 Rough Electnc COMM Inspector Act Rl MC MC PY MC MC MC MC MC MC MC Fl CA AP AP AP PA AP PA CO PA TORREY PINES BANK- 646 SF REMODEL BANK TO BANK Comments AM PLS - COF PER CONTRACTOR HARD LID AT TUNNEL WALLS ONLY HARD LID PER REVISED PLAN WALLS ONLY NOT PER PLAN WALLS ONLY Wednesday, January 22, 2014 Page 1 of 1 0 INSPECTIOM RECORD CARD WITH APPROVED PLANS MUST BE KEPT OW THE JOB 0 CALL BEFORE 3:30 pm FOR NEXT WORK DAY INSPECTION 0 FOR BUILDING INSPECTION CALL: 760-602-2725 OR GO TO: www.CarlsbaiJca.qov/Biuilding AND CLICK ON "Request Insfsesjtion'^ / / \ Oc DATE: €8130377 2760 GATEWAY RD TORREY PINES BANK- 646 SF REMODEL BANK TO BANK Tl COMM Lot# ANNE SNEED ARCHITECTURAL INTERIORS NO YES Required Prior to Requesting Building Final If Checked YES Date Inspector Notes 7^ Lancfscape 760-944-8463 Allow 48 hours _/ CM&I (Engineering Inspections) 760-438-3891 Call before 2 pm v Fire Prevention 760-602-4660 Allow 48 hours Type of inspection Type of Inspection ^mmmmmmssmm Date Inspector Date Inspector #11 FOUNDATION #31 • ELECTRIC UNDERGROUND • UFER #12 REINFORCED STEEL > #34 ROUGH ELECTRIC IfiAiA^' e>iipf oS»/e>^/f3 Mo #66 MASONRY PRE GROUT #33 • ELECTRIC SERVICE DTEMPORARV • GROUT • WALL DRAINS #35 PHOTO VOLTAIC. • #10 TILT PANELS . ' #39 FINAL #11 POUR STRIPS #11 COLUMN FOOTINGS #41 UNDERGROUND DWTS& PIPING #14 SUBFRAME • FLOOR DCEIUNG #44 DDUCTSt PLENUM D REF PIPING < #15 ROOFSHEATHING #43 HEAT-AIR COND. SYSTEMS #13 EXT SHEAR PANELS #49 FINAL #16 INSULATION - #18 EXreR'ORLATH #81 UNDERGROUND (ll,12,2i;31) - #17 INTERIOR LATH & DRYWALL He #82 DRYWALL,EXT LftTH, GAS TES (17,18,23^ #51 POOLEXCA/STEEL/BOND/FENCE #83 ROOFSHEATIN^, EXT SHEAR (13,15) - J #55 PREPLASTER #84 FRAME ROUGH COMBO (1.4,24,34,44) J b/e>i( 13. #19 FINAL #89 nNAL0CCUPANCY{19,29,39,49) U L Date inspector #22 • SEWER &BL/CO • PL/GO Date Inspector #21 UNDERGROUND OWASTE • WTR #24 TOP OUT • WASTE DWTR A/S UNDERGROUND VISUAL #27 TUB & SHOWER PAN A/SUNDERGROUND HYDRO #23 • GAS TEST • GAS PIPING , A/SUNDERGROUND FLUSH i #25 WATER HEATER i f^jf/l A/S OVERHEAD VISUAL #28 SOLAR WATER ^ X A/S OVERHEAD HYDROSTATIC #29 FINALfn* ni-piz /i5Xir P A/S FINAL F/AROUGH-JN #600 PHE-CONSTRUCTION IWEEnNG F/A FINAL #603 FOLLOW UP INSPECTION FIXED EXnNGUISHING SYSTEM ROUGH-IN #605 NOTICE TO CLEAN FDCED EXriNG SYSTEM HYDROSTATIC TEST #507 WRIHEN WARNING FDCED EXTINGUISHING SYSTEM HNAL #609 NOTICE OF VIOUTION MEDICAL GAS PRESSURETEST #610 VERBALWARNING MEDICAL GAS FINAL - REV 10/2012 •SEE BACK FOR SPECIAL NOTES Section 5416. Health and Safety Code, State of California (a) There shall be not less than one water closet for each 20 employees or fractional part thereof working at a construction job site The water closet shall consist of a patented chemical type toilet (b) For thG purpose of this section the term construction site shall mean the location on which actual construction of a building is in progress (c) A violation of this section shall constitute a misdemeanor All construction or work for which a permit is required shall be subject to inspection and all such construction or work shall remain accessible and exposed for inspection purposes until approved by the inspector Work shall not be done beyond the point indicated in each successive inspection without first obtaining the approval of the inspector DATE ADDITIONAL NOTES w t f -To -e^tr^n of iftc^ FtA(lL6i^£r> trt.©o& . / y 1 9 ^11 2 K-UK 1 ^ 7^ ^ Fiee^' Bv:ti- -^Oo>vA uuo^ JL^;k. V^AXse^-er^Mr^^ Carlsbad 13-0377 i 5/20/13 EsGil Corporation In Partnership witH government for (BuiCding Safety DATE 5/20/13 • APPLICANT Ef JURIS JURISDICTION Carlsbad • PLAN REVIEWER • FILE PLAN CHECK NO 13-0377 SET III PROJECT ADDRESS 2760 Gateway Rd PROJECT NAME Torrey Pines Bank, Training Rm and Storage Rm Tl ^ The plans transmitted herewith have been corrected where necessary and substantially comply with the junsdiction's building codes I I The plans transmitted herewith will substantially comply with the junsdiction's codes when minor deficiencies identified below are resolved and checked by building department staff I I The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck I I The check list transmitted herewith is for your information The plans are being held at Esgil Corporation until corrected plans are submitted for recheck I I The applicant's copy of the check list is enclosed for the junsdiction to forward to the applicant contact person I I The applicant's copy of the check list has been sent to XI EsGil Corporation staff did not advise the applicant that the plan check has been completed I I EsGil Corporation staff did advise the applicant that the plan check has been completed Person contacted Telephone # Date contacted (by ) Email Fax # Mail Telephone Fax In Person • REMARKS By Chuck Mendenhall Enclosures EsGil Corporation • GA • EJ • PC 5/13/13 EsGil Corporation In Partnership with government for (BuiCrfing Safety DATE 5/6/13 • APPLICANT J^URIS JURISDICTION Carlsbad • PLAN REVIEWER • FILE PLAN CHECK NO 13-0377 SET II PROJECT ADDRESS 2760 Gateway Rd PROJECT NAME Torrey Pines Bank, Training Rm and Storage Rm Tl I I The plans transmitted herewith have been corrected where necessary and substantially comply with the junsdiction's codes I I The plans transmitted herewith will substantially comply with the junsdiction's codes when minor deficiencies identified below are resolved and checked by building department staff I I The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck ^ The check list transmitted herewith is for your information The plans are being held at Esgil Corporation until corrected plans are submitted for recheck I I The applicant's copy of the check list is enclosed for the junsdiction to forward to the applicant contact person XI The applicant's copy of the check list has been sent to Anne Sneed Architecture, Att'n Anne Sneed 4757 Sun Valley Rd , Del Mar, CA 92014 I I EsGil Corporation staff did not advise the applicant that the plan check has been completed IX EsGil Corporation staff did advise the applicant that the plan check has been completed Person contacted Anne Sneed Telephone # (858) 356-9212 Date contacted C 11/ (by Email Cyndi@annesneed com Fax # ,^^<^|ail^ vyelephone Fax In Person • REMARKS By Chuck Mendenhall Enclosures EsGil Corporation • GA • EJ • PC 4/29/13 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576 Carlsbad 13-0377 5/6/13 Please make all corrections, as requested in the correction list Submit FOUR new complete sets of plans for commercial/industnal projects (THREE sets of plans for residential projects) For expeditious processing, corrected sets can be submitted in one of two ways 1 Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave , Carlsbad, CA 92008, (760) 602-2700 The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineenng and Fire Departments 2 Bnng one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468 Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineenng and Fire Departments NOTE Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineenng and Fire Departments until review by EsGil Corporation is complete NOTE: The items listed below are from the previous correction list. These remaining items have not been adequately addressed. The numbers of the items are from the previous check list and may not necessarily be in sequence. The notes in bold font caps and underlined are current. Corridors shall have fire partition walls and ceiling of one-hour construction when required by Table 1018 1 Show the locations of the rated corndors on the plans or clearly show compliance with an applicable exception from Section 1018 1 Provide a details section of the corridor walls and ceiling to show the required 1 HR protection. YOU HAVE SHOWN THE LOCATION OF THE FIRE RATED CORRIDOR. THE PARTITION LEGEND ON SHEET A4.01 REFERS TO 1 HR WALL CONSTRUCTION. REFERENCE ON THE LEGEND ON SHEET A4.01 THE WALL CONSTRUCTION DETAIL THAT APPLIES ON SHEET A9.01. Corndors shall have intenor door openings protected by tight-fitting smoke and draft control assemblies rated 20 minutes Doors shall be maintained self-closing or be automatic - closing by action of a smoke detector per Section 715 4 8 Doors shall be gasketed to provide a smoke and draft seal where the door meets the stop on sides and top Section 715 DOORS 100 & 103 LISTED ON SHEET A10.01 AS 20 MIN. MUST ALSO. BE SELF CLOSING. THE HARDWARE SCHEDULE DOES NOT INDICATE "SELF CLSING" DEVICE FOR THESE DOORS. Duct penetrations (or air transfer openings) of fire-rated corridor construction shall have fire and smoke dampers per Sections 716 Show on the plans the locatin of ducts and registers within the corridor and lobby. Clearly note on the plans these are to be equipped with smoke/ fire dampers. SHEET M0.1 SHOWS THE DUCTS PENETRATING THE WALLS OF THE CORRIDOR TO BE EQUIPPED WITH SFD ( DAMPERS ). THIS WOULD LEAD ME TO BELIEVE THAT THE DUCTS AND REGISTERS INSIDE THE CORRIDOR ARE BELOW THE 1 HR RATED CEILING. THE FIRE RATED TUNNEL DETAIL 11/A9.01 WOULD LEAD ME TO BELIVE THE DUCTS ARE ABOVE THE 1 HR CEILING SO THE SFD MUST BE LOCATED IN THE CEILING REGISTERS. PLEASE CLARIFY YOUR INTENT. Carlsbad 13-0377 5/6/13 7 Provide a complete architectural section of the corndor, showing all fire-resistive matenals and details of construction for the fire partition walls and roof/ceilings and all penetrations Section 107 2 See Section 709 4 CLARIFY WHICH WALL AND CEILING DETAILS SHOWN ON SHEET A9.01 APPLY WITHIN THE FIRE RATED CORRIDOR. MISCELLANEOUS 9 Wall elevations A & B on sheet A8 01 show the top of the walls consist of window panels Expand detail B on sheet A9 01 to show how you intend to resist out-of-plane loads where the glass panels meet the stud wall construction This applies to both the top and bottom of the windows shown in B on sheet A9 01 THIS CORRECTION STILL APPLIES. THE WALL ELEVATIONS SHOWN ON SHEET A8.01 SHOWS WINDOWS WITHIN THE NEW PARTITION WALLS. I PRESUME THAT DETAIL 5/A9.01 APPLIES TO THESE WALLS. HOW DO YOU PROVIDE OUT-OF-PLANE LATERAL SUPPORT @ TOP AND BOTTOM OF THE WINDOW? END OF CODE RECHECK To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i e , plan sheet, note or detail number, calculation page, etc The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123, telephone number of 858/560-1468, to perform the plan review for your project If you have any questions regarding these plan review items, please contact Chuck Mendenhall at Esgil Corporation Thank you EsGil Corporation In (Partnership wtth government for (Building Safety DATE 2/27/13 • APPLICANT JURIS JURISDICTION Carlsbad • PLAN REVIEWER • FILE PLAN CHECK NO 13-0377 SET I PROJECT ADDRESS 2760 Gateway Rd PROJECT NAME Torrey Pines Bank, Training Rm and Storage Rm Tl I I The plans transmitted herewith have been corrected where necessary and substantially comply with the junsdiction's codes I I The plans transmitted herewith will substantially comply with the junsdiction's codes when minor deficiencies identified below are resolved and checked by building department staff I I The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck X The check list transmitted herewith is for your information The plans are being held at Esgil Corporation until corrected plans are submitted for recheck I I The applicant's copy of the check list is enclosed for the junsdiction to forward to the applicant contact person X The applicant's copy of the check list has been sent to Anne Sneed Architecture, Att'n Anne Sneed 4757 Sun Valley Rd , Del Mar, CA 92014 I I EsGil Corporation staff did not advise the applicant that the plan check has been completed IX EsGil Corporation staff did advise the applicant that the plan check has been completed Person contacted Anne Sneed Telephone # (858) 356-9212 Date contacted T'l'^-^ (by VV^) Email Cyndi@annesneed com Fax # V^WIail "telephone Fax In Person • REMARKS By Chuck Mendenhall Enclosures EsGil Corporation • GA • EJ • PC 2/19/13 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576 Carlsbad 13-0377 2/27/13 PLAN REVIEW CORRECTION LIST TENANT IMPROVEMENTS PLAN CHECK NO 13-0377 JURISDICTION Carlsbad OCCUPANCY B USE bank TYPE OF CONSTRUCTION VB ACTUAL AREA 650 Tl Only ALLOWABLE FLOOR AREA No change STORIES 1 HEIGHT no change SPRINKLERS'? NO OCCUPANT LOAD 150 REMARKS DATE PLANS RECEIVED BY JURISDICTION DATE PLANS RECEIVED BY ESGIL CORPORATION 2/19/13 DATE INITIAL PLAN REVIEW COMPLETED 2/27/13 PLAN REVIEWER Chuck Mendenhall FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the California version of the International Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electncal Code and state laws regulating energy conservation, noise attenuation and access for the disabled This plan review is based on regulations enforced by the Building Department You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineenng Department, Fire Department or other departments Clearance from those departments may be required prior to the issuance of a building permit Code sections cited are based on the 2010 CBC, which adopts the 2009 IBC The following items listed need clanfication, modification or change All items must be satisfied before the plans will be in conformance with the cited codes and regulations Per Sec 105 4 of the 2009 International Building Code, the approval of the plans does not permit the violation of any state, county or city law To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e.. plan sheet number, specification section, etc. Be sure to enclose the marked up list when vou submit the revised plans. Carlsbad 13-0377 2/27/13 Please make all corrections, as requested in the correction list Submit FOUR new complete sets of plans for commercial/industnal projects (THREE sets of plans for residential projects) For expeditious processing, corrected sets can be submitted in one of two ways 1 Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave , Carlsbad, CA 92008, (760) 602-2700 The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineenng and Fire Departments 2 Bnng one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468 Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineenng and Fire Departments NOTE Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineenng and Fire Departments until review by EsGil Corporation is complete The exit plan on sheet A3 01 shows two exits but the number of exits summary on the same page indicates 2 exits required, 3 exits provided Provide consistent plans and notes NOTE The building information found on sheet A1 01 indicates the bidg does not have a fire spnnkler system The tenant improvement will now create an exit corndor The following Corndors shall have fire partition walls and ceiling of one-hour construction when required by Table 1018 1 Show the locations of the rated corndors on the plans or clearly show compliance with an applicable exception from Section 1018 1 Provide a details section of the corridor walls and ceiling to show the required 1 HR protection Fire-resistance rated exit corndors shall not be interrupted by intervening rooms Foyers, lobbies or reception rooms constructed as for corndors shall not be construed as intervening rooms Section 1018 6 The existing Open office , lobby area is an extension of the fire rated corridor. Detai on the plans the construction of the walls and ceiling of the lobby to comply as part of the 1 HR corridor Corndors shall have intenor door openings protected by tight-fitting smoke and draft control assemblies rated 20 minutes Doors shall be maintained self-closing or be automatic closing by action of a smoke detector per Section 715 4 8 Doors shall be gasketed to provide a smoke and draft seal where the door meets the stop on sides and top Section 715 This applies to existing doors and new doors within the newly created corridor. Windows in the walls of fire-rated intenor corndor walls (Section 715 5) The following applies to all existing and new windows located within the corridor • Such openings shall be protected by glazing listed and labeled for a fire-protection rating of at least 3/4-hour (or Vi-inch thick wired glass in steel frames) • The maximum width or height of such windows shall not exceed 54 inches, and the maximum area may not exceed 1,296 square inches • The total area of such windows shall not exceed 25% of the area of a common wall with any room Section 715 5 8 2 Carlsbad 13-0377 2/27/13 6 Duct penetrations (or air transfer openings) of fire-rated corndor construction shall have fire and smoke dampers per Sections 716 Show on the plans the locatin of ducts and registers within the corridor and lobby. Cllearly note on the plans these are to be equipped with smoke/ fire dampers. 7 Provide a complete architectural section of the corndor, showing all fire-resistive matenals and details of construction for the fire partition walls and roof/ceilings and all penetrations Section 107 2 See Section 709 4 8 When two exits are required, dead end corridors are limited to 20 feet Section 1018 4 The new corndor will create a dead end corridor in excess of 20ft at the existing rest rooms • MISCELLANEOUS 9 Wall elevations A & B on sheet A8 01 show the top of the walls consist of window panels Expand detail B on sheet A9 01 to show how you intend to resist out-of-plane loads where the glass panels meet the stud wall construction This applies to both the top and bottom of the windows shown in B on sheet A9 01 10 Revise and clean up the suspended ceiling notes found on sheet A9 02 to comply with the current code as listed below Detail 5/A9 02 is completely not legible Detail 3 / A9 02 refers to the UBC and UBC Standards which are no longer applicable provide notes on the plans to show the suspended ceilings in Seismic Design Categories D, E & F comply with ASCE 7- 05 Section 13 5 6 2 1 as follows • All ceilings shall use a Heavy Duty T-bar grid system • The width of the penmeter supporting closure angle shall be not less than 2 inches • In each orthogonal horizontal direction, one end of the ceiling gnd shall be attached to the closure angle • The other end in each horizontal direction shall have a ^/4" clearance from the wall and shall rest upon and be free to slide on a closure angle or a listed assembly END OF CODE REVIEW To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i e , plan sheet, note or detail number, calculation page, etc The junsdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123, telephone number of 858/560-1468, to perform the plan review for your project If you have any questions regarding these plan review items, please contact Chuck Mendenhall at Esgil Corporation Thank you Carlsbad 13-0377 2/27/13 [DO NOT PAY- THIS IS NOT AN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION Carlsbad PLAN CHECK NO 13-0377 PREPARED BY Chuck Mendenhall DATE 2/27/13 BUILDING ADDRESS 2760 Gateway Rd BUILDING OCCUPANCY B TYPE OF CONSTRUCTION VB BUILDING PORTION AREA ( Sq Ft) Valuation Multiplier Reg Mod VALUE ($) Tl 650 City est 23,980 Air Conditioning Fire Spnnklers TOTAL VALUE 23,980 Junsdiction Code cb By Ordinance Hdg Permit Fee by Oidinance ^ Plan Check Fee by Ordinance Type of Review 0 Complete Review [^Repetitive Fee ^ Repeats • Other l_l Hourly EsGil Fee • Structural Only Hr @ $264 07 $171.65 $147 88 Comments Sheet 1 of 1 macvalue doc + ^ CITY OF CARLSBAD BUILDING PLANCHECK CHECKLIST QUICK-CHECK/APPROVAL Development Services Land Development Engineering 1635 Faraday Avenue 760-602-2750 www carlsbadca gov ENGINEERING Plan Check for CB13-377 Date 02/28/13 Project Address 2760 GATEWAY APN Project Description BANK TO BANK Valuation $23,980 ENGINEERING Contact Kathleen Lawrence Phone 760-602-2741 Email kathleen,lawrence@carlsbadca.gov Fax 760-602-1052 RESIDENTIAL INTERIOR LZl TENANT IMPROVEMENT LJ RESIDENTIAL ADDITION MINOR INTERIOR ONLY (<$20,000.00) CI CARLSBAD PREMIER OUTLETS • PLAZA CAMINO REAL • COMPLETE OFFICE BUILDING • OTHER: CELL ANTENNAS OFFICIAL USE ONLY ENGINEERING AUTHORIZATION TO ISSUE BUILDING PERMIT BY- KATHLEEN LAWRENCE REMARKS NO ADDITIONAL ENG. FEES DATE 02/28/13 1 Notification of Engineering APPROVAL has been sent to via EMAIL on 02/28/13 E-36 Page 1 of 1 REV 4/30/11 ^ CITY OF PLAN CHECK Community & Economic ^ CITY OF REVIEW Development Department 1635 Faraday Avenue CARLSBAD TRANSMITTAL Carlsbad CA 92008 www carlsbadca gov DATE:02/28/13 PROJECT NAME: TORREY PINES BANK PLAN CHECK NO: 1 SET#: 1 ADDRESS: 2760 GATEWAY VALUATION: $23,980 PROJECT ID: CB13-377 APN: /] This plan check review is complete and has been APPROVED by the ENGINEERING • Division. By: KATHLEEN LAWRENCE 02/28/13 A Final Inspection by the Division is required L jYes bdNo " j This plan check review is NOT COMPLETE. Items missing or incorrect are listed on - -I the attached checklist. Please resubmit amended plans as required. Plan Check Comments have been sent to: CYNDI@ANNESNEED COM You may also have corrections from one or more of the divisions listed below. Approval from these divisions may be required prior to the issuance of a building permit. Resubmitted plans should include corrections from all divisions. For questions or clanfications on the attached checklist please contact the following reviewer as marked v;:^£ilRE PRg^EI^TSl^i^^fl ; 1 Chris Sexton ' * 760-602-4624 Chris Sexton@carlsbadca gov [7/1 Kathleen Lawrence LXJ 760-602-2741 Kathleen Lawrence@carlsbadca gov r 1 Greg Ryan • J 760-602-4663 Gregorv Rvan@carlsbadca gov 1 1 Gina Ruiz '—' 760-602-4675 Gina Ruiz@carlsbadca gov ~! Linda Ontiveros L^.J 760-602-2773 Linda Ontiveros@carlsbadca gov 1 Cindy Wong '--^ 760-602-4662 Cynthia WongOcarlsbadca gov j— "| 1 I j j 1 Dominic Fieri 1 i 760-602-4664 Dominic Fieri@carlsbadca gov Remarks: -•^ CITY OF CARLSBA PLANNING DIVISION BUILDING PLAN CHECK APPROVAL P-29 Development Services Planning Division 1635 Faraday Avenue (760) 602-4610 www carlsbadca gov DATE: 2/20/13 PROJECT NAIVIE: T.I. PROJECT ID: PLAN CHECK NO: CB130377 SET#: ADDRESS: 2760 GATEWAY RD APN: ^ This plan check review is complete and has been APPROVED by the PLANNING Division. By: GINA RUIZ A Final Inspection by the PLANNING Division is required • Yes ^ No Vou may also have corrections from one or more of the divisions listed below. Approval from these divisions may be required prior to the issuance of a building permit. Resubmitted plans should include corrections from all divisions. This plan check review is NOT COMPLETE. Items missing or incorrect are listed on the attached checklist. Please resubmit amended plans as required. Plan Check APPROVAL has been sent to: CYNDI@ANNESNEED.COM For questions or clarifications on the attached checklist please contact the following reviewer as marked PLANNING , - 760-602-4610 ENGINEERING 760-602-2750' FIRE PREVENTION 760-602-4665 1 1 Chns Sexton 760-602-4624 Chris Sexton@carlsbadca gov 1 1 Kathleen Lawrence 760-602-2741 Kathleen Lawrence@carlsbadca gov Greg Ryan 760-602-4663 Gregory Rvan@carlsbadca gov 1 1 Gina Ruiz 760-602-4675 Gina RuizOcarlsbadca gov 1 1 Linda Ontiveros 760-602-2773 Linda Ontiveros@carlsbadca gov Cindy Wong 760-602-4662 Cynthia Wong@carlsbadca gov • 1 i Dominic Fieri 760-602-4664 Dommic FieriOcarlsbadca gov Remarks: ORG. BLDG PERMIT APPROVED UNDER CB054205 <!«> ^ CITY OF PLAN CHECK REVIEW TRANSMITTAL unity & Economic Development Department 1635 Faraday Avenue Carlsbad CA 92008 www carlsbadca gov DATE: 2-26-13 PROJECT NAIVIE: Torrey Pines Bank PROJECT ID: cbl30377 PLAN CHECK NO: CB130377 SET#: I ADDRESS: 2760 Gateway Rd APN: • This plan check review is complete and has been APPROVED by the Fire Division. By: D. Fieri A Final Inspection by the Fire Division is required |^ Yes • No This plan check review is NOT COMPLETE. Items missing or incorrect are listed on the attached checklist. Please resubmit amended plans as required. Plan Check Comments have been sent to: you may also have corrections from one or more of the divisions Usted below. Approval from these divisions may be required prior to the issuance of a building permit. Resubmitted plans should include corrections from all divisions. For questions or clarifications on the attached checklist please contact the following reviewer as marked PLANNING 760-602-4610 ENGINEERING 760-602-2750 FIRE PREVENTION 760-602-4665 1 1 Chris Sexton 760-602-4624 Chns Sexton@carlsbadca gov 1 1 Kathleen Lawrence 760-602-2741 Kathleen LawrenceOcarlsbadca gov Q Greg Ryan 760-602-4663 Gregory Rvan@carlsbadca gov 1 1 Gina Ruiz 760-602-4675 Gma Ruiz@carlsbadca gov 1 1 Linda Ontiveros 760-602-2773 Linda Ontiveros@car!sbadca gov 1 1 Cindy Wong 760-602-4662 Cvnthia WongOcarlsbadca gov • • X Dominic Fieri 760-602-4664 Dommic Fieri@carlsbadca ^ov Remarks: Carlsbad Fire Department BLDG. DEPT COPY Plan Review Requirements Category Tl, COMM Date of Report 02-26-2013 Reviewed by Name ANNE SNEED ARCHITECTURAL INTERIORS Address 4757 SUN VALLEY RD DEL MAR CA 92014 Permit # CB130377 Job Name TORREY PINES BANK- 646 SF Job Address 2760 GATEWAY RD CBAD —INCOftlPLETE The itiMii )ou have jubmittod for roviow lo inoomploto At tliio timo, tlua UAILL Ldimot " adoquatoly conduct a review lu dt^tiMimiic complmnoG with the applicable codes a»d/oi' atawdarda Pleaae ravrnw • oorofully all oommonta attaoliud Pkaae roaubniit tlio woec^jai'ji plana aiid;^ui ipLtifiLaliuiis, willi Lluiigbs "lluudud", •it(j this uffigi9 for rovio¥r and appiu ^ al • Cuud CON0006104 [MET] THIS PROJECT HAS BEEN REVIEWED AND APPROVED FOR THE PURPOSES OF ISSUANCE OF BUILDING PERMIT THIS APPROVAL IS SUBJECT TO FIELD INSPECTION AND REQUIRED TEST, NOTATIONS HEREON, CONDITIONS IN CORRESPONDENCE AND CONFORMANCE WITH ALL APPLICABLE REGULATIONS THIS APPROVAL SHALL NOT BE HELD TO PERMIT OR APPROVE THE VIOLATION OF ANY LAW Entry 02/26/2013 By df Action AP INDUSTRIAL WASTEWATER DISCHARGE PER' SCREEMiNG SURVEY Business Name'"|{)' Street Address Email Address PLEASE CHECK HERE IF YOUR BUSINESS IS EXEMPT (ON REVERSE SIDE CHECK TYPE OF BUSINESS) Check all below that are present at your facility Acid Cleaning Ink Manufactunng Nutntional Supplement/ Assembly Laboratory Vitamin Manufactunng Automotive Repair Machining/Milling Painting/Finishing Battery Manufacturing Manufactunng Paint Manufactunng Biofuel Manufacturing Membrane Manufactunng Personal Care Products Biotech Laboratory (i e water filter membranes) Manufactunng Bulk Chemical Storage Metal Casting / Forming Pesticide Manufactunng / Car Wash Metal Fabncation Packaging Chemical Manufacturing Metal Finishing Pharmaceutical Manufacturing Chemical Purification Electroplating (including precursors) Dry Cleaning Electroiess plating Porcelain Enameling Electncal Component Anodizing Power Generation Manufacturing Coating (i e phosphating) Pnnt Shop Fertilizer Manufacturing Chemical Etching / Milling Research and Development Film/X-ray Processing Printed Circuit Board Rubber Manufacturing Food Processing Manufactunng Semiconductor Manufactunng Glass Manufacturing Metal Powders Forming Soap / Detergent Manufactunng Industrial Laundry Waste Treatment/Storage SIC Code(s) (If known) Brief descnption of business activities (Production / Manufacturing Operations) ^/Jilfij^ Descnption of operations generating wastewater (discharged to sewer, hauled or evaporated) Estimated volume of industnal wastewater to be discharged (gal / day) List hazardous wastes generated (type/volume) hj I ^ Date operation began/or will begin at this location Have you applied for a Wastewater Discharge Permit from the Enema Wastewater Authority? Yes ^9) if yes, when Site Contact Signature ENCINAW Title Phone No iORITY, 6200 Avenida Enemas Carisbad, CA 92011 (760)438-3941 FAX (760)476-9852 SAN DIEGO REGIONAL HAZARDOUS MATERIALS QUESTIONNAIRE OFFICE USE ONLY UPFP# H\m BP DATE / / '•^fSS-'i^^ Wrb ?MHLV^ ''moo'] Mailing Address . I ^ ^, City ' . State Zip CJode Plan File* The following questions represent the facility's activities, NOT the specific project descnption PART I FIRE DEPARTMENT - HAZARDOUS MATERIALS DIVISION OCCUPANCY CLASSIFICATION Indicate by circling the item, whether your business will use, process, or store any of the following hazardous matenals If any of the items are circled, applicant must contact the Fire giofection Agency with junsdiction pnor to plan submittal Facility's Square Footage (including proposed project) '^'^•'XJi-\ Occupancy Rating jp> 1 Explosive or Blasting Agents 5 Organic Peroxides 9 Water Reactives 13 Corrosives 2 Compressed Gases 6 Oxidizers 10 Cryogenics 14 Other Health Hazards 3 Flammable/Combustible Liquids 7 Pyrophoncs 11 Highly Toxic or Toxic Matenals 15 None of These 4 Flammable Solids 8 Unstable Reactives 12 Radioactives PART II SAN DIEGO COUNTY DEPARTMENT OF ENVIRONMENTAL HEALTH - HAZARDOUS MATERIALS DIVISIONS (HMP) If the answer to any of the questions is yes, applicant must contact the County of San Diego Hazardous Materials Division, 5500 Overland Ave , Suite 110, San Diego, CA 92123 Call (858) 505-6700 pnor to the issuance of a building permit Project Completion Date / \ ^? Expected Date of Occupancy 0^/ \^ / FEES ARE REQUIRED • CalARP Exempt Date Initials • CalARP Required I Date Initials • CalARP Complete I Date Initials YES NO ~ (for new construction or remodeling projects) • -Is your business listed on the reverse side of this form'' (check all that apply) D ^•QL. Will your business dispose of Hazardous Substances or Medical Waste in any amount"? • "^->Will your business store or handle Hazardous Substances in quantities equal to or greater than 55 gallons, 500 pounds 200 cubic feet, or carcinogens/reproductive toxins in any quantity'' • Will your business use an existing or install an underground storage tank'' • ^rAwill your business store or handle Regulated Substances (CalARP)'' • •Q'-J^/ill your business use or install a Hazardous Waste Tank System (Title 22, Article 10)'' • ^Cj/Vill your business store petroleum in tanks or containers at your facility with a total storage capacity equal to or greater than 1,320 gallons'' (California's Aboveground Petroleum Storage Act) PART 111 SAN DIEGO COUNTY AIR POLLUTION CONTROL DISTRICT If the answer to any of the questions below is yes, applicant must contact the Air Pollution Control District (APCD), 10124 Old Grove Road, San Diego, CA 92131-1649, telephone (858) 586-2600 pnor to the issuance of a building or demolition permit Note if the answer to questions 4 or 5 is yes, applicant must also submit an asbestos notification fonn to the APCD at least 10 working days pnor to tannmenang demolition or renovation, except demolition or renovation of residential structures of four units or less Contact the APCD for more information YES NO 1 D subject facility or construction activities include operations or equipment that emit or are capable of emitting an air contaminanf (See the APCD factsheet at htto //wvwv sdaocd oro/info/facts/permits odf, and the list of typical equipment requinng an APCD permit on the reverse side of this from Contact APCD if you have any questions) 2 • (ANSWER ONLY IF QUESTION 1 IS YES) Will the subject facility be located within 1,000 feet of the outer boundary of a school (K through 12)'' •"^^ (Search the California School Directory at http //www cde ca oov/re/sd/ for public and private schools or contact the appropnate school distnct) 3 D Has a survey been performed to determine the presence of Asbestos Containing Matenals'' 4 • >0^Will there be renovation that involves handling of any fnable asbestos matenals, or disturbing any matenal that contains non-fnable asbestos'' 5 • ^3-—Will there be demolition involving the removal of a load supporting structural member'' Bnefly descnbe business activities Bnefly descnbe proposed project perjury that to the best of my knowledge and belli m are true and correct Name of Owner or Authonzed Agent Date FIRE DEPARTMENT OCCUPANCY CLASSIFICATION . BY FOR OFFICIAL USE ONLY DATE EXEMPT OR NO FURTHER INFORMATION REQUIRED RELEASED FOR BUILDING PERMIT BUT NOT FOR OCCUPANCY RELEASED FOR OCCUPANCY COUNTY-HMD* APCD COUNTY-HMD APCD COUNTY-HMD APCD *A stamp in this box onlv exempts businesses from completing or updating a Hazardous Matenals Business Plan Other permitting requirements may still apply HM-9171 (02/11) County of San Diego - DEH - Hazardous Matenals Division « ^ CITY OF CARLSBAD PLUMBING, ELECTRICAL, MECHANICAL WORKSHEET B-18 Development Services Building Division 1635 Faraday Avenue 760-602-2719 www carlsbadca gov Project Address. Qj/ssiH-^A-^^^^ Permit No.: Information provided below refers to work bemg done on the above mentioned permit only This form must be completed end returned fo the Building Division before the permit con be issued. Building Dept. Foot (760) 602-8558 Number of new or relocated fixtures, traps, or floor drains New building sewer line' Ves_ Number of new roof drains' Install/alter water line' Number of new water heaters' Number of new, relocated or replaced gas outlets' Number of new hose bibs? No «^ 4/0 ~0 " '0 Residential Permits: New/expanded service Number of new amps- Minor Remodel only Ves No Commercial/Industrial: Tenant Improvement- Number of exIsUng amps inrjolvedm tfiis project- Number of new amps involved in this proiect: New Construction: Amps per Panel. Single Phase Number of new amperes_ Three Phase Number of new amperes_ Three Phase 480 Number of new amperes_ Number of new fumaces, A/C, or heat pumps? New or relocated duct wort?? Ve$_ Number of new fireplaces' Number of new exhaust fans' Relocate/install vent? , Number of new exhaust hoods' No iy - o ^ Number of new boilers or compressors? .r:. Number of HP 'A B-18 Page 1 of 1 Rev 03/09 CB130377 2760 GATEWAY RD TORREY PINES BANK- 646 SF RF MODEL BANK TO BANK hl^ill?>- OayA^OL -f^fs6.^i^ /^/ryllL <^(S^/^ • cv Final Imp AppfOVed Date By BUILDING Oth/QJCflr. PLANNING ^/^// 3 &< ENGINEERING FIRE Expedite? DP AFS Checked by HazMat APCD Health Forms/Fees Sent Reed Due? By Encina Y N Fire Y N HazHealthAPCD Y N PE&M Y N School Y N Sewer Y N Stormwater — Y N Special Inspection Y N CFD y N LandUse Density ImpArea FY Annex Factor PFF Y N Comments Date Date Date Date Building Planning Engineenng Fire Need? • Done • Done • Done • Done • Done SW • Issued