Loading...
HomeMy WebLinkAbout2780 LOKER AVE W; ; CB931358; PermitB U I L D I N G P E R M I T Permit No: CB931358 Project No: A9301948 Development No: 03/01/94 11:06 1 Page 1 of 1 Job Address: 2780 LOKER AV WEST Permit Type: INDUSTRIAL TENANT IMPROVEMENT Parcel No: 209-081-25-00 Valuation: 15,000 Construction Type: VN Suite: Lot#: Occupancy Group: B2 Reference#: Description: PARTITION WALLS 10' STORAGE Appl/Ownr : LEIGH AEROSYSTEMS 2780 LOKER AVENUE WEST CARLSBAD, CA 92008 *** Fees Required Fees: ~djustments: Total Fees: Fee description Building Permit Plan Check Strong Motion Fee * BUILDING TOTAL Enter "Y" for Plumbi Enter "Y" for Electri Remodel/Alter Per AMP * ELECTRICAL TOTAL Enter 'Y' for Mechanical Install Furn/Ducts/Heat P * MECHANICAL TOTAL 619 CITY OF CARLSBAD Status: Applied: Apr/Issue: Entered By: 930-4060 ISSUED 12/20/93 01/07/94 DC .00 305.00 24.00 *** Ext fee Data 162.00 105.00 3.00 270.00 10.00 25.00 35.00 15.00 9.00 24.00 N y y SP. ~~f ~i~~~1 ~EARANCE _____ 1 2075 Las Palmas Dr., Carlsbad, CA 92009 (619) 438-1161 PLAN CHECK NO. City of Carlsbad Building Department a • 2075 Las Palmas Dr •• carlsbad, CA 92009 (619) 438-1161 F.sT. VAL PLAN CK __ D_EPOSIT ___ ..3_,.. .. -3 ....... ---- VAIJD. BY DC 1. PfiltM.I I IYl4: DATE /,,2, I ,,3D 7 9~ A -U Commercial LI New Bmldmg U Tenant Improvement B -Mlndustrial U New Building lll'Tenant Improvement C -0 Residential Cl Apartment Cl Condo O Single Family Dwelling O Addition/ Alteration 0 Duplex O Demolition D Relocation O Mobile Home O Electrical Cl Plumbing 0 Mechanical Cl Pool Cl Spa Cl Retaining Wall Cl Solar C Other ____ _ 2. PRQJF.Cf INFORMATION FOR OFFICE USE ONLY Address ~'?8 0 Lo/i~,-t_ Afil.C/J,tL~dA1J Buildmg or Smte No. Nearest Cross Street /.4l 9")J ~ A-/-~,, 1J· U LEGAL DESCRIPTION Lot No. sutxhVIs10n Name/Nupber 1 1(.*i:::IJ. ~2. "(Jb lfl4f·t:I ',3o50 0mt No. Phase No. CHECK BEWW IF sOBMll IEb: D 2 Energy Cales a 2 Structural Cales a 2 Soils Report D I Addressed Envelope /!;fl-4/f/~ ,._)4ll5 # OF STORIES / ADDRESS /;CJ, /7'7J' Jf'Jtj_ ?v; tf· NAME Gt:1~D o.v t-, HA,1ll..lS CI1Y R.., >, r_ STATE c4- ADDRESS f, o, 6o Ji f/'5 I ZIP CODE 9-ltJ(; fl DAY TELEPHONE CI1Y STATE ADDRESS ZIP CODE DAY TELEPHONE 6. CDN'tRAciOR NAME t,w r,t,t_ ADDRESS CI1Y STATE ZIP CODE LICENSE C1ASS ADDRESS DAY TELEPHONE STATE UC.# CI1Y BUSINESS UC. # DESIGNER NAME CI1Y OWrt~fJ(/L STATE ZIP CODE DAY TELEPHONE STATE UC. # 1. WOIUMts' WMP£NSA110N Workers' Compensation beclaratton: I hereby affirm that I have a certthcate of consent to self-insure issued by the Director of lndustnal Relations, or a certificate of Workers' Compensation Insurance by an admitted insurer, or an exact copy or duplicate thereof certified by the Director of the insurer thereof filed with the Building Inspection Department (Section 3800, Lab. C). INSURANCE COMPANY POLICY NO. EXPIRATION DATE Certthcate of Exemption: I certify that m the performance of the work for whtch thts penmt ts issued, I shall not employ any person m any manner so as to become subject to the Workers' Compensation Laws of California. SIGNATURE DATE s. oWN"mt-llOIIDER DECi.ARAl1oN Owner-Bm@er Declaration: I hereby afftrm that I am exempt from the Contractor's License Law for the followmg reason: I, as owner of the property or ·my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's Llcense Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale.). Cl I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's Llcense Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). Cl I am exempt under Section ________ Business and Professions Code for this reason: (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law (Chapter 9, commencing with Section 7000 of Division 3 of the Business and Professions Code) or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects a licant to a ivil penalty of not more than five hundred dollars [$500]). SIGNATIJRE f'-DATE / ~ Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? C YES ilt'NO Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? a YES D NO Is the facility to be constructed within l,QOO feet of the outer boundary of a school site? C YES 11:r"'NO IF ANY OF 1lIE ANSWERS ARE YFS, A FINAL CERTIFICATE OF CXDJPANCY MAY NOf BE 1$UED AFTER JULY 1, 1989 UNLF.'iS 1lIE APPUCANT HAS MET OR IS MEETING 1lIE REQUIREMENTS OF nm OFFICE OF EMERGENCY SERVICF.S AND nm AIR POI.LUTION CDNlllOL rnsnucr. 9. wNslR0CuON Lf:NDING AGENCY I hereby afhrm that there ts a construction lending agency for the performance of the work for whtch thts permit ts issued (Sec 3097(1) CtVIl Code). LENDER'S NAME LENDER'S ADDRESS lo. APPIJcAN't cmtlMCA'11oN l certify that l have read the appltcat10n and state that the above mformatton ts correct. [ agree to comply wtth all Ctty ordinances and State laws relating to building construction. I hereby authorize representatives of the City of Carlsbad to enter upon the above mentioned property for inspection purposes. I AISO AGREE 10 SAVE INDEMNIFY AND KEEP HARMI.F.SS 1lIE CTlY OF CARISBAD AGAINSf AIL UABIUTIF.S, JUDGMENTS, CDSTS AND EXPENSES WIIlCH MAY IN ANY WAY ACDUJE AGAINSf SAID CTlY IN CDNSEQUENCE OF 1lIE GRANTING OF 11IlS PERMIT. OSHA: An OSHA permit is required for excavations over 5'0" deep and demolition or construction of structures over 3 stories in height. Expiration. Every permit issued by the Building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 365 days from the date of such permit or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days (Section 303(d) Uniform Building Code). DATE: I J-l'lj 7 APPLICANTS SIGNATU:~ j /fatu; WHITE: File YEU..OW: Applicant PINK: Finance .,, . CITY OF CARLSBAD INSPECTION REQUEST PERMIT# CB931358 FOR 03/~/94 DESCRIPTION: PARTITION WALI.S 10' STORAGE~! TYPE: ITI INSPECTOR AREA TP PLANCK# CB931358 OCC GRP B2 CO~STR. TYPE VN STE: LOT: JOB ADDRESS: 2780 LOKER AV WEST APPLICANT: LEIGH AEROSYSTEMS CONTRACTOR: PHONE: 619 PHONE: 93=1 OWNER: REMARKS: RS/LEE SPECIAL INSTRUCT: TOTAL TIME: --RELATED PERMITS--PERMIT# TYPE AS940008 ASTI PHONE: INSPECTOR-~~'---------- STATUS ISSUED CD LVL DESCRIPTION ACT COMMENTS 19 ST Final Structural $ _________ _ 29 PL Final Plumbing 39 EL Final Electrical 49 ME Final Mechanical 1=------------------------------------------------------------ ***** INSPECTION HISTORY***** DATE 031594 030794 030794 030794 030794 022894 020794 011494 011294 011094 011094 021793 DESCRIPTION Rough/Ducts/Dampers Final Structural Final Plumbing Final Electrical Final Mechanical Final Combo Compliance Investigation Interior Lath/Drywall Interior Lath/Drywall Frame/Steel/Bolting/Welding Rough Electric Final Combo ACT AP co co co co co co AP NR AP AP co INSP TP TP TP TP TP TP TP PD TP TP TP PD COMMENTS DUCTS SUP & RES ND MECH PLANS SEE NOTES T-BAR INSP,C/0 LEFT .• FAX COVER SHEET • No. of Pages (Incl. cover): • Destination FAX Number: TO: FROM: DATE: SUBJECT: 3 278-8539 ATTN: Mike Chris-Air Gene Ward February 28, 1994 Building Inspection Cert. LEIGH Aerosystems Corporation 2780 Loker Avenue West Carlsbad, CA 92008 Tel: (619) 930-4060 FAX: (619) 9304064 Comment the inspector wrote is, "Submit mechanical plan with heating and cooling system for storage rooms# 1,2, and 3, as built for approval. Permit required for mechanical work". These are "storage" rooms and require temperature control for the equipment to be stored. He said just the outlets and ducting plan is required. Mike, this is all we need for a final inspection, so we would appreciate getting this cleared as soon as possible. The following two (2) pages are a rough ceiling plan we used for the sprinklers; perhaps you could use. If you need anything from me, please give me a call. Thanks, 4 /,U,pvC Gene Ward l0'd P90p0[66l9 d~OJ SW31SASO~3~ H8137 6c:01 P66l-Bc-a3~ FINAL BUitDING INSPECTION DEPT: BUILDING ENGINEERING' FIRE PLANNING U/M WATER PLAN CHECK#: CB931358 PERMIT#: CB931358 PROJECT NAME: PARTITION WALLS 10' STORAGE ADDRESS:· 2780 LOKER AV WE~T CONTACT PERSON/PHONE#: MH/GENE/930-4060 SEWER DIST: CA WATER DIST: CA DATE: 02/17/94 PERMIT TYPE: ITI BY: {,,L{l, INSPECTE~ft . ~t~!ECTED: c:;) !cJt-fM<J APPROVED L DISAPPROVED INSPECTED BY: INSPECTED BY: COMMENTS: DATE INSPECTED: DATE INSPECTED: APPROVED DISAPPROVED APPROVED DISAPPROVED DATE: ESGIL CORPORATION 9320 CHESAPEAKE DR., SUITE 208 SAN DIEGO, CA 92123 (619) 560-14-68 LJ APPLICANT JURISDICTION: ~DIC11IOI!> nXiicHECKER PLAN CHECK NO: QFILE COPY QUPS 0DESIGNER PROJECT ADDRESS: ~13D \...o\~L< Q..>.NL, PROJECT NAME: I\ I \ I --'----"--------------'--- D D 0 D The plans transmitted herewith have been corrected where necessary and substantially comply with the .jurisdiction's building codes. · The plans transmitted herewith will substantially-comply with the jurisdic~ion's building codes when minor deficien- cies identified-=-------------are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corp. until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to return to the applicant contact-person. 0 The applicant's copy of the check list has been sent to: IJ Esgil staff did not advise the applicant contact person that plan check has been comnleted. -. O Esgil staff did advise applicant that the plan check has been completed. Person contacted: ------------- Date contacted: _________ Telephone# _______ _ D REMAR~S: --------------------------- By: Q, \' ~{l_d,y<,. .. Enclosures:_~~-o-~-k-______ _ ESGIL CORPORATION '\3- OcM D.~TE: ESGIL CORPORATION 9320 CHESAPEAKE DR., SUITE 208 SAN DIEGO, CA 92123 (619) 560-1468 JURISDICTION: ?LAN CHECK NO: (..b q3_ 13 53 SET: Z PROJECT ADDRESS:_---::~~?~?~o=--~L~o~k~,rt.-.A~v~<...~------- PROJECT NAME: //, /. -----'-------------------- D D D II D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdic~ion's building codes when minor deficien-cies identified _____________ are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check-list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corp. until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to return to the applicant contact person. 9 The applicant's copy of the check list has been sent to: 0¢2,/1 ,.Jd$or, ~o. pc>,c. 3i'-{~ --:Z, s,;=-, C..,, II Esgil staff did not advise the applicant contact person that plan check has been completed. O Esgil staff did advise applicant that -the plan check has been completed. Person contacted: ___________ _ Date contacted: _________ Telephone# _______ _ D REMARKS: --------------------------- By: Al, ~ADr2.~' Enclosures: __ "'-~'-o~~~-'-=------- ESGIL CORPORATION / f). ~ I 0 GA D CM (31>c PLAN CHECK NO.: Co -13 -1358 ( :£) rnsn1cnoN: Ca y f 2 t;,A..d PROJECT DA'.I:A ) OCCUPANCY: 'iG;::,-~ BUil.J)ING USE: _ __,,a .... 1.,.,.,~..:..' ...,4-=-i/...:Y-.A"""""'"'<--= .... · h'-'-"o...,cJ-=~:;;.;..,_=--- TYPE OF CX>NSIRDC'.tIOH:_...,,.,¥'. __ ..;a_a...;.;!'-... '-------- ACIUAL ARF.A: A, )p t;..}:u. ""· ~ ,.__ ALLaiABLE ARF.A: ___ NQ'""""-"CbA::;....a:; .... t'l...i~ .... ,------ S'l'ORIES: _____ 0 ________________ _ BEIGHr: __ 1:a1.,.i..:,.:::=~----------------- SPRDUCLERS: _ _..,,..~~) .... ,_L=------------- OCCOPAHI LOAD:_..,.$ .... 0-_________ _ Date plans received by jurisdiction: Date plans received by Esgil Corporation: Date initial plan check completed: ___ 1 ..... J,+-] _d_l.....,..I ..... :1 ...... 3.....__By:_ .... S-......a .... d=-ve.. _____ _ I Applicant contact person: _ _.;;;;'b=-,.._l .,_I _____ Tel. C, 3o ,.. i..t-oLPD FORE.WRD: .PLF.ASE READ Plan check is limited to technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and i;;tate laws regulating energy conservation, noise attenuation and access for the handicappe~. The plan check is based on regulations enforced by the Building Inspection Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department, Fire Department or other departments. Code sections cited are based on the 1991 UBC. Clearance from those . ·· ... - departments may be required prior to the issuance · .-_. ·: _ R»IARKS: ____________________ _ of a building permit. Ihe circled items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 303(c), 1991 U~iform Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed up the recheck process, note on this list (or a copv) where each correction item has been addressed, i.e., plan sheet, specification, etc. Be sure to enclose the marked up list when vou . submit the revised plans. :NOTE: PAGE HtJmERS ARE HO? Ilf ~ AS PAGES HAVING NO IlE1S NEEDING CORREcrIONS WERE Dll.EIED. LIST NO. 40 TENANT IMPROVEMENT WITHOUT SPECIFIC ENERGY ZONE DATA OR POLICY SUPPLEMENTS, 1991 UBC -··-- .. · .. . .. -· • ··v . --.·.-:-,· 0 I G G )· I I ' )· r· Please make all corrections on the original tracings and submit two new sets of prints, to: Esgil Corporation, 9320 Chesapeake Drive, Suite #208, San Diego, CA 92123, (619) 560-1468. Please make all corrections on the original t~acings and submit two new sets of prints, to: The jurisdiction's building department. Indicate on the Title Sheet of the plans, the name of the legal 9wner and name of person responsible for the preparation of the plans. Section 302(d). Each sheet of the plans must be signed by the person responsible for their preparation, even .though there are no structural changes. Business and Professions Code. Plans and calculations shall be signed by the California state licensed engineer or architect where there are structural changes td existing buildings or structural additions. Please include the California license number, seal, date of license expiration and date plans are signed. Business· and Professions Code. Provide the correct address and suite number of tenant space on the plans. Section 302(d). Provide a note on the site plan indicating the previous use of the tenant space or building being remodeled. Section 302. When the character of the occupancy or use changes within a building, the building must be made to comply with current Building Code requirements for the new occupancy. Please provide complete details to show the building with comply. Section 502. · UBC Section 304 requires the Building Official to determine the total value of all construction work proposed under this permit. Ihe value shall include all finish work, painting, roofing·, electrical, plumbing, heating, air conditioning, elevator, fire extinguishing systems and any other permanent equipment. Please provide a signed copy of the designer's or contractor's construction cost estimate of all work proposed. Provide a plot plan showing the distance from the building to the property lines and the location of tenant space (or remodel) within tlle building. 8/4/92 (::\ On the first sheet of the lans ind · a · Q ype o construction o the exis..t.inwuilding, present and proposed occupancy classifications of the remodel area and the occupant load of the remodel areas and the floor where the f· f· tenant imptovernent is located. Provide a note on the plans indicating if any hazardous materials will be stored and/or used within the building which exceed the quantities listed in UBC Tables 9-A and 9-B. A complete des·cription of the activities ,md processes that will occur in this tenant space should be provided. A listing of all hazardous materials should be included. The materials listing should be stated in a form that would make classification in Tables 9-A and 9-B ~ossible. The building official may require a technical report to identify and develop methods of protection from hazardous materials. Section 901(f). If control areas are used for exceeding the exempt amounts of hazardous materials from Tables 9-A and 9-B, they shall be constructed of not less that required for a one-hour occupancy separation. Section 404. The number of control areas within a building used for retail/wholesale stores shall not exceed two; the number of control areas in buildings with other uses shall not exceed four. Footnote 1, Tables 9-A and 9-B. l/j. The aggregate quantity of any hazardous / materials "in use" and "in storage" shall not · exceed the quantity listed in Tables 9-A and 9-B for "storage". Footnotes 2 and 3, Tables 9-A and 9-B. Q Provide a statement on the Title Sheet .of the ~ 1 plans that this project shall comply with Title 24 and 1991 UBC, UMC and UPC and 1990 NEC. 0 Provide a fully dimensioned floor plan shov~ the size and use of all rooms or areas within . the space being improved or a!tered. Draw the plans to scale and indicate the scale on the plan. Section 302(d). "",z.,O :>f'~'=5..,T-'+) • 1~ Indicate the use of all spaces adjacent to the '/' area being remodeled or improved. r· I· Show any existing fire rated area separation walls, occupancy separation walls, demising walls, shafts OJ;' rated corridors. Identify and provide-construction details for proposed new fire rated walls. Specify on the plans the fire ratings of assemblies to protect penetrations or proposed openings in existing or new fire walls, floor- ceiling assemblies or roof-ceiling assemblies. 2 f· Identify existing walls to be removed, existing walls to remain and proposed new walls. Identify bearing walls, non-bearing walls, and shear walls. Show safety glazing in the following locations, per Section 5406(d): a. Where the nearest edge of glazing is within a 24-inch arc of either side of a door in a closed postion (unless there is an intervening wan between the door .and the glazing .or if the glazing is 5' -011 or b. c. higher above the walking surface). Glazing greater than 9 square feet with the bottom edge less than 1811 above the floor and the top edge greater than 3611 above the floor (unless the glazing is more than 3611 horizontally away from walking surfaces o_r if a complying protective bar is installed) •. Glazing in shower and tub enclosures (including windows· within 5 feet of tub or shower floor), ~ Provide a section view of all new interior \~ partitions. Show: I· G G 1· Type, size and spacing of studs. Indicate gauge for metal studs. Specify manufacturer and approval number or indicate "to be ICBO approved". Method of attaching top and bottom plates to structure. (NOTE: Top of partition must be secured to roof or floor framing, unless suspended ceiling has been designed for partition lateral load). /C,6:, 11t 'Jer ~Iv~ p,,.,, Wall sheathing material and details of attachment (size and spacing of fasteners). Show height of partition and suspended ceiling, and height from floor to roof framing or floor framing. Provide notes and/or details to show that the floor and wall finish in toilet · rooms are surfaced· with a smooth hard non-absorbent material extending five inches up the wall. Similar surfacing shall be provided on the walls from the floor to a height of 4 feet around urinals and within water closet compar_tments. Section Sl0{b). Note on the plans: "All interior finishes must comply w~ Chapter 42 of the UBC". Specify "Class Jp... flame spread rating (minimum) for C:Zc 2: , II Note on plan that suspended ceilings shall COll!PlY with UBC Tables 47-A and 23-P. In buildings having floors and roofs of wood frame construction, other than dwelling or hotel occupancies, draft stop the area between the ceiling and floor above so that no concealed space exceeds 1,000 s.f. and no horizontal dimension exceeds 60 L.F. (if space has sprinklers, then 3,000 s.f. and 100 L.F.). Section 2516(f). 7/8/92 G i I· In buildings having floors and roofs of wood frame construction, other than dwelling or hotel occupancies, draft stop·the area between the ceilin and roof above so a concea e space exceeds 31000 s.f. and no horizontal dimension exceeds 60 L.F. (if space has sprinklers, then 9,000 s.f. and 100 L.F.). Section 2516(f). Storage areas exceeding 1000 sq. ft. in connection 1.:ith wholesale or retail sales shall be separated from t..~e public area by a one-hour occupancy separation. If the entire building has an automatic sprinkler system, then the occupancy separation need not be provided. Section 702(c). An automatic sprinkler system shall be installed in rooms used by the occupants for the consumption of alcohol and in accessory uses· where the total area of such unseparated rooms and assembly uses exceeds 5000 square feet. Section 3802(c). 0oi The tenant space and new and/or existing \Q facilities serving the ~emodeled area must be accessible to and functional for the physically disabled. See the attached G f· correction sheet. Title 24, Part 2. J1~ ,..rr.z a.,l( e.,,_ ,~T,;: c,..l;r,:; & Y<. ~ .<.., Co,. I , The width o the re uire v e si e into which doors swing shall extend 24 inches past the strike edge for exterior doors and 18 inches past the strike edge for interior doors. Section 2-3304, Title 24. ,n e.,t,sJ,'ii C6rr,dtJY Specify leve-type hardware for passage doors on floors accessible to the disabled. Section 2-3304, Title 24 •. If both sexes will be employed and the number of employees exceeds four, provide separate toilet facilities for men and women. If "both sexes will be employed and the total number of employees will not exceed four", and only one restroom is provided, note the words in quotation above on the floor plan. Section 705(c). A -~....,...,...---hour occupancy separation is required between _____ ...,..,_occupancy and the ______ occupancy. Table 5-B. Ducts penetrating occupancy or area separation walls must have fire dampers. Section 4306 (j). . C\ In areas where the occupant load exceeds 3o, \J two exits are required. See._=1;,:,-'",.'-'"'"-'.;>,._ ___ _ Table 33-A. · ?A. Provide an exit analysis plan (may be 8 l/211 x /~ 1111 or any convenient size). ~ Exits should have a minimum separation of on~-V half the maximum overall diagonal dimension of the building or ~ea served. Section 3303(c). ~ '1t !>"8 3 G I· G r· f· G 4/ 0 j· f· ¥· r· The maximum number of required exits and their required separation must be maintained until egress is provided from the structure. Section 3303(a). S....,....."fl 38 Rooms with more than 10 occupants may have~ exit through~ adjoining room. Revise exits to comply. Section 3303(e). Exit signs are required whenever two exits are required. Show ali required exit sign locations. Section 3314 (a). Show that exits are lighted with at least one foot candle at floor level. Section 3313(a). Show the locations of existing exits from the building and show.the path of travel from the ~emodel area to the existing exits. Note on the plans: 11All exits are to be openable from inside without the use of a key or special knowledge". In lieu· of the above, in a Group B occupancy, you may note "Provide a sign on or near the exit doors reading THIS DOOR TO REMAIN UNLOCKED DURING BUSINESS HOURS". This signage is only allowed at the main exit. Section 3304(c). Exit doors. should be a minimum size of 3 feet by 6 feet 8 inches with a mini.mum door swing ~f · 90 degrees. Maxi.mum leaf width is 4 feet. Section 3304(f). Exit doors should swing in the direction of egress when serving an occupant load of 50 or more or when serving any hazardous area. Section 3304{b). Applies to door(s) ___ _ Regardless of occupant load, a floor or landing not more than 1/2 inch below the threshold is required on each side of an exit door used for disabled access (may be 111 maxi.mum where not used for disabled access). Section 3304{i). Doors should not project more than 7 inches into the required corridor width when fully opened, nor more than one-half of the required corridor width when in any position. Section 3305(d). Revolving, sliding and overhead doors are not permitted as exit doors if the occupant load exceeds 9 or the exit door serves a hazardous area. Section 3304(h). Provide panic hardware in Group A,E,H-l,H-2,H-3 and I occupancies. Chapter 33. Double acting doors are not allowed when serving a tributary occupant load of more than 100, or when part of a fire assembly, or part of smoke and draft control assemblies or when equipped with panic hardware. Section 3304(b). 5/28/92 G Corridors must provide continuous protection to the exterior of the building. · Interruptions by an intervening room, is not permitted. Foyers, lobbies or reception rooms constructed as requi-red for corridors are not consJdered intervening rooms. Section 3305. ~sr 5S I Corridors and exterior exit balconies serving 10 or more occupants must be a minimum 44 inches wide and 7 feet high to the lowest I· 0 proje<;tion. Corridors serving less than 50 occupants may be a mini.tr.Jill of 36 inches in width. Section 3305(b). When two exits are required, dead end corridors and exit balconies are limited to 20 feet. Section 3305(e). Corridors serving 30 or more occupants shall have walls and ceilings of one-hour construction. Show compliance or clearly show on plans which of the following exceptions has been satisfied: ./· Corridors greater than .30 feet wide when the occupants have an exit independent from the corridor. 0 !· G I Exterior sides of exterior exit balconies. Corridor walls and ceilings need not be of fire-resistive construction within office spaces having an occupant load of 100 or less when the entire story in which the space is located is equipped with an automatic sprinkler system throughout and smoke detectors are installed within the corridor in accordance with their listing. Within office spaces occupied by a single tenant, partial height partitions which form corridors and which do not exceed 6 feet-in height need not be fire resistive, provided they are constructed in accordance with Section 1705 and are .not more than three fourths of the floor- to-ceiling height. Section 3305 (g). Section 3305(g), Exceptions, cannot be used for non-rated corridors in a fully sprinklered office space if the occupant load in the space exceeds 100. Section 3305{g), Exception 5 does not apply to common corridors where the corridor serves as an exit for non-office areas (manufacturing, warehouse, etc.). Section 3305(g), Exception 5 is applicable only for corridors on one floor; the corridors on the lower level(s) must be rated if these lower corridors have openings into them from other·levels. 4 Section to the Y If non-rated cor~idors are used per 3305(g), Exe. 5, provide a reference corridors on the floor plan, noting: 1. Corridors are non-rated per Section 3305(g), Exception 5. G G 0 f 2·. Smoke detectors shall be maximum 30 1 on center. 3. Power supply shall be dedicated branch circuit. · Circuit disconnecting means shall be accessible only to authorized personnel and shall be clearly marked FIRE ALARM CIRCUIT CONTROL, with a lock-on device. · If a tenant space utilizes Section 3~05(g), Exception 5, then that tenant space shall be separated from adjacent spaces by a demising wall constructed as for a one-hour corridor wall. oJ1'lL / V"-"1!.~o~ Clearly show where the non-rated corridor system terminates and a rated corridor system coimnences. One-hour fire-rated corridors shall have interior door openings protected by tight- fitting smoke and draft control assemblies rated 20 minutes, except openings in interior walls of exterior exit balconies. Doors shall be maintained self·cloi:iing or be automatic- closing by action of a smoke detector per Section 4306(b). Poors shall be gasketed to provide a smoke and draft seal where the door meets the stop on sides and top. Section 3305(h). Total area of all openings, except doors, in any portion of an interior corridor, shall not exceed 25 percent of the area of the corridor wall of the room which it is separating from the corridor.· Such openings shall be protected by fixed glazing listed and labeled for a fire- protection rating of at least 3/4-hour. Section 330S(h). 0 Show rated corridors, lobbies, reception or foyers cross-hatched on the floor plans. ~ Provide a complete architectural section of V the corridor, or exterior exit balcony, showing all fire-resistive materials and details of construction for all floors, walls, ceiling and all penetrations. Section 0 3305(g). Show the location of fire dampers. Provide fire dampers at duct penetrations of fire- rated occupancy and area separations, shafts and corridor ceilings. Combination fire/smoke dampers are required at duct penetrations of rated corridor walls. Section 4306(j). 8/4/92 G I· G If a room with an exhaust fan has a door opening into a rat~d corridor, show how make- up air will be provided to the room. The door cannot be undercut, nor can a louver in the door be provided. Section 3305(h)l. If building exceeds two stories and· has an elevator opening into a rated corridor, show how the smoke and draft control provision of Section 3305(h) will be met. Either provide a separated elevator lobby or a second door at the ele\'atcr entry oeeting the provision. Section 3305(j). If a second door is provided at the elevator entry, note that it will be readily openable from the car side without a key, tool or special knowledge or effort. Section 5106. New provisions in Chapter 43 of the 1991 UBC require special treatment of penetrations at fire-resistive assemblies. Provide typical details on the plans showing how the fire- resistive integrity will be maintained at the f o 11 owing conditions ( Inc 1 u de the manufacturers' names and .ICBO numbers (or equal) for any sealant): A, THROUGH-PENETRATIONS (through the entire assembly): 1. Fire-resistive bearing walls and/or walls requiring protected openings shall have penetrations protected with through- penetration fire stops having an F- rating, I-rating or complying with UBC Standard 43-1, depending on their locations, sizes and combustibility. 2. Fire resistive floor/ceiling assemblies. shall have pen~trations protected with through-penetration fire stops having and F-rating, T-rating or complying ~ith UBC Standard 43-1, depending on their sizes, combustibility and whether the penetrations are in walls above. B. MEMBRANE-PENE'IRATIONS (through only one side of an assembly): . 1. Fire-resistive walls (whether bearing· or not and whether requiring fire protected openings or not) shall have penetrations protected with membrane-penetration fire stops having an F-rating or complying with UBC Standard 43-1, depending on their size and combustibility. Limited steel electrical. outlet boxes (not exceeding 16 sq •. in., nor more than 100 sq. in. for any 100 sq. ft. of wall) require no protection. 2. Fire-resistive ceilings shall have no penetrations, except for noncombustible sprinkler pipes and steel electrical outlet boxes as described above. NOTE: The plans should indicate the various fire-stop ratings · require·d for all penetrations. Provide a note on the plans stating "Penetrations of fire-resistive walls, floor- ceilings and roof-ceilings shall be protected . as required in UBC Sections 4304 and 430511 • 5 I· I· r· G G G Ja. I· ,. f· J'· Provide evidence of Health Department approval (for restaurants or for tenants using X-ray equipment). If nonflammable supply cylinders for medical gas systems are located inside buildings, show how they comply with UBC Section 702(c)4. ELECTRICAL Submit plan showing location of all panels. Submit panels schedules. Submit electrical load calculations Indicate existing main service size. Indicate existing total main service load. Indicate new additional loads. Indicate wiring method, i.e. EMT, metal flex. Show exit signs on the electrical lighting plan(s). As per Section 3313 and 3314 of the 1991 UBC, provide two sources of power to exit signs and exit illumination. Provide receptacle{s) within 25 1 of HVAC units. UMC Section 509. Provide multiple switch lighting controls per Title 24, Part 6. MECIANICAL Provide mechanical ventilation in all rooms capable of supplying a minimum of 5 cubic feet per minute of outside air with a total circulation of not less than 15 cubic feet per minute per occupant. Section 605 and 705, UBC. Provide mechanical plans showing existing and proposed HVAC equipment, ducts and I access to equipment. Detail access and working clearances to HVAC equipment. Detail disposal of main condensate drainage from· air conditioning units. (UMC Section 510} Detail overflow (secondary) co_ndensate discharge from air conditioning units that are in a ceiling space. (UMC Section 1205) Fire rated corridors are not to be used to convey air to or from rooms. UMC Section 1002. PLtlmING Provide gas line plans and calculations, showing pipe lengths and gas demands. UPC Section 1219. 8/4/92 Provide drain, waste and vent plans. Provide water line sizing calculations. UPC Section 1009. G Detail how floor drain trap seal is to be maintained. UPC Section 707 (floor drain trap priming). Show P & T valve on water heater and detail drain line route from P & T valve to the exterior. UPC Section 1007(e) •• Al.=so :;,I-.,,..) c .. .::.c.,>-_, 1 1 ·f· .k t... s~,s '"'" c... s ~"'t, \o..-it. Show 1/411 per 12" s ope on drain and waste lines. UPC Section 407. Provide a drinking fountain at each floor level in assembly occupancies (except drinking and dining establishments). UBC Section 605. Note on the plans that new water closets and associated flushometer valves, if any, shall use no more than 1. 6 gallons per flush and shall meet performance standards established by the American National Standards Institute Standard All2.19.2, and urinals and associated flushometer valves, if any, shall use no more than one gallon per flush and shall meet performance standards established by the American National Standards Institute Standard Al12.19.2. H & S Code, Section 17921.3{b). EHERGI G Provide complete energy design calculations, including all existing design and new energy design for this building. ice: alilc:Wieiil "'" ~acidU'ltial efte~gy dicis;a &beak•ict .Q. For remodels in an existing conditioned space, \J show that the remodeled space will not use more energy than the existing space or show the remodeled space will conform to lates.t energy design standards. . :==:dditional corrections or remarks that follow. Io speed up the recheck process, note on this list (or a copy} whee each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. ,Q Please indicate here if ~y changes have been Q made to the plans that _ are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please check. ____ Yes _____ .No 6 The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 619/560-1468, to perform the.plan check for your project. If you have any questions regarding these plan check items, please contact. _______ _ s~ dr-« at Esgil Corporation .Thank you. Enclosures: 2. ____________________ _ 3. _____________________ _ 8/4/92 7 I· J. The surface of ramps r· resistant. 2-3307{g) shall be slip- I· I· )· j I· I· I· I· A 60" :intermediate landing is required at maximum elevation change of 30'' and 7211 landing at each change of direction (over _30 degrees). 2-3307(d.l) Landings are required at top and bottom . of ramps. 2-3307(d.l) Bottom landing shall be mini.I.r..i:n of 7211 in the direction of travel. Fig. 2-33- llA Top landing shall be 60" x 60" i:;inimum. 2-3307(d.l) h'ben · door swings onto top landing, mini::ru.m depth of landing required is door width plus 4211 • 2-3307(d.l_.) Top landing shall have 6011 .min. width w~en door swings onto the landing, with 2411 on strike side of door at exterior ramp, or 1811 at interior ramp. 2-3307{d.l) Ramp handrails are required on each side of ramp, when slope exceeds l·in 15. 2- 3307(e.l) Ramp handrails shall be continuous, located 30"-3411 in height above ramp surface, with 1211 extensions beyond top and bottom, and the ends returned. 2-3307{e.l) m,i Handrails shall be 1-1/411 to 211 cross / section, spaced minimum of 1-1/211 from wall. 2-3307{e.l) I· A 211 high curb or wheel guide rail centered 311 .:!: 111 above ramp surface is required on both sides where not otherwise bounded by walls when·the ramp exceeds 10 feet in length. 2-3307(h.l) SPECIAL ACCESS LIFIS a. Lifts may be provided between levels, :in lieu of elevator,· when the vertical distance between .. landings, structural elevator, structural design· and safeguards are as allowed by the State of California, Department of Industrial Relation~, Division of Occupational Safety and Health. .2-5107(a) . The lift platform shall be of sufficient si~e to acco1.1modate a wheelchair (30"x48"). 2-5107{a) /· There shall be a level and clear floor area or landing {60"x60") at each level for access to the lift. 2·5107(a) l HAZARDS a. Provide 8011 headroom from .walkway / surface to any overhanging obstruction. 2-3326(b) / • Headroom of maintained for etc. 2-522(f) 80'' minimum shal 1 be walks, corridors, aisles, c/. Protruding objects with leading edges / between 27" and 80" above finished floor shall not protrude more than 411 into walks, corridors, etc. 2-522(f) f Free standing objects mounted on posts between 27" and 80" above the floor may project a caximum of 1211 • 2-522(f) / Abrupt changes in level exceeding 411 adjacent to walks, except between walks and adjacent streets or drives, shall be identified by 611 high .. .-arning curbs above walk surface. 2-3326(a) EN'IRANCES AND CIRCOLATION ()ENTRANCES, DOORS, VESTIBULES AND CORRIDORS (. All primary entrances to buildings shall be accessible to the handicapped. 2-330l(f) !· All required passage doors shall have 3211 clear opening at 90 degrees (3611 door). 2-3304(f) I At least one of a pair of doors shall • meet the minimum 3211 clear entrance width requirement. 2-3304(f) @ Threshold shall be no higher than 1/2" above the floor. Edge to be beveled with a slope no greater than l in 2, if more than 1/411 • 3304{i.l) 0 Exterior level landing may slope up to 1/411 per. foot in any direction for surface drainage. 2-413 · @ Door hardware shall be of the lever or push type, mounted 3011 to 4411 above the floor and be operable with a maximum effort of 8.5 lbs. for exterior doors and 5 lbs. for :interior doors. 2-3304(c), 2- 3304(i.2) W The lower 1011 of the door shall be of smooth, plane surface (no recess or trap) except at automatic and sliding doors. 2-3304(i.3) Building entrance(s) shall be identified by sign with the International Symbol of Accessibility. Show location on plan. The symbol shall be a white figure on blue background. 2-522(b) Y At turnstile, provide an access gate, 3211 clear width opening, within 30 feet of ·turnstile. 2-3304(i.4) I There shall be a clear area on each side of door, 6011 deep :in direction of door swing and 4411 deep in opposite direction of door swing. 2-3304(i.~) 20. BATHING FACILITIES ;l I One such facility shall provided for the public, employees. 2-511.l{a) comply 1,;hen clients or Shower compartment shall be 4211 .,;ide, 4811 deep, with a 3611 wide entrance. 2-511.l(a) Show on the plans that the handicapped bathing facilities shall conform to requirements of Sec. 2-Slla-9, 5-1505 and 5-1506, i.e., folding seat, flexible shower hose, etc. GENERAL REQUim{EXtS 1. DRINKING FOUNTAIN .4.. Drinking fountains shall be within {-alcoves. The alcove shall be not less than 3211 wide by 1811 deep. 2-511.l(c) I c. When the enforcing agency determines that it would create .an unreasonable hardship to locate the water fountain in an alcove, the water .fountain may project into the path of travel, and the path of travel shall be identifiable to the blind as follows: (1.) The surface of the path of travel at the water fountain shall be textured so that it is clearly identifiable by a blind person using a cane. The minimum textured area shall extend from the wall supporting the water fountain to 1 foot beyond the front edge of the water fountain and shall extend 1 foot beyond each side of the water fountain, or (2.) Wing walls shall be provided on each side of the water fountain. The wing walls shall project out from the supporting wall at least as far as the water fountain to within 6 inches of the surface of the ·path of travel. Also, there shall be a. minimum of 32 inches clear between the wing walls. Note on the plans that drinking fountain shall conform to requirements of Sec. 2-511c and 5-1507. 1· PUBLIC TELEPHONE / • Provide space 3011 x 4811 for forward or parallel approach to telephone. 2-511.l(d) 'If. Note on the plans that public telephone / shall· conform to requirements of (::\ Sec. 2-511.l(d_). V, ELECIRlCAL REQUIRoo:NTS 0 15, 20 and 30 amp receptacle outlets shall be installed not less than 1211 above floor. 3-210-50(e) 0 Center of switches shall be located.not less than 3611 ·nor mor·e than 4811 above the floor. 3-380-S(c) / • PLUMBING REQUIREMENTS . / . Where kitchenettes are provided at employee break rooms, conference areas, customer lounges, etc., the faucet controls at kitchen sinks shall be operable with one hand and shall not require tight grasping, pinching or twisting of the ',,,Tist (i .. e., use lever- operated, push-type, etc.). If self- closing valves are used, they shall re1:1ain open for at least 10 seconds. 5-1508 . . GROOP A OCCUPANCY REQUim{EXtS f AUDITORIUMS, ASSEMBLY HALLS, THEATRES, ETC. I Seating and toilet facilities for the handicapped shall be accessible from the main lobby or primary entrance. I ;I. I 2-6ll(b) This structure requires -----,,,---,---- wheelchair seating spaces. In theaters and auditoriums, the seating shall be provided in a variety of locations so as to provided a choice of admission prices. 2-6ll(b) Each wheelchair space shall be 6011 x 3011 and level. 2-611(b) When the seating capacity exceeds 300, the wheelchair spaces shall be in more than one location. 2-611(b) rl. This structure requires ------,,.,,--/ -seats for semi-ambulant persons. Clear ). leg space shall be at least 2411 • 2-6ll(b) Stages, enclosed and unenclosed platforms, orchestra pits, ticket booths, and refreshment sales facilities shall be made accessible. 2-611(b) 2j{: STADIUMS, GRANDSTANDS,. BLEACHERS, PAVILIONS, / GYMNASIUMS This structure requires --------wheelchair seating spaces. In theaters and auditoriums, the seating shall be provided in a variety of locations so as to provided a choice of admission prices. 2-6ll(c) I When the seating capacity exceeds 300, the wheelchair spaces shall be in more than one location. 2-6ll(c) 1~ i. I Ticket booths must be accessible from both sides. 2-611{c) Participation areas such as ball courts., exercise rooms, tracks, and clubrooms must be accessible. 2-6ll(c) Spectator and participant sanitary and locker facilities must conform to the requirements of Chapter 2-5. 2-61l(c) Date 1 )). / ~ l \ ~~ Jurisdiction LA<\::i~N;\ Prepared bys 60-4r~ VALUATION AND PLAN CHECK FEE D :Sldg, Dept. ~sgil PLAN CHECK NO, C .. :t::,q2,-\559 (J:) -BUILDING ADDRESS _,.ci'-l .... :8 ..... 0-.... N....,__,_IL....,,: __ .,, ___ {) __ ,V(._--=--'---------------- APPLI CANT/CONTACT __ '.s;:,-=-----' \ .... \_____ PHONE NO. __ U ____ ~_,.. __ + __ o .... h~Q,.___ BUILDING OCCUPANCY --~P=-~~,4.'--'"--DESIGNER PHONE ------ TYPE OF CONSTRUCTION __ --s:z-=-~-~N-'------CONTRACTOR PHONE ------ BUILDING PORTION BUILDING AREA VALUATION VALUE MULTIPLIER ~. \,· \o) Ob-JS-5o, ("J"'OO -I ' Air Conditionine: Comrner·c.ial @ Residential (cl Res. or Comm. Fire S'Drinklers @ Total Value ~o, znro, ,,-- Building Perm it Fee $ ___________________ $_ .... ;>"""8:-_~~·_,:5,c.i,::O __ Plan Check f'ee $ $ 1'8'4 ,q5 -"----------------------'"---'-.:::-'--.:..:::..-- COM MEN TS ... :----------------------------- SHEET (D OF (D 12/87 :·: . ~ : .. . : •.· .... · -. ··,.:.·--~ .. -:"-.. .. . -.::-::· ; a-_;. __ -: .-· •. /~::::~::/ -.:·· .. : .·• ..... .. ·.-........ ~ . _: .... .- .•;;. :.- PLANNING/ENGINEERING APPROVALS PERMIT NUMBER CB f 7-1 3,S ?DATE __ /.--,?;,._~_;?_o_/2_1/'_3 __ I ADDRESS __ -t::c;),,,,,_7 __ ~_Q __ L_~_~__;_~_/€'..,.___,_4_~_&-_-'-tcPL..C...)Jf'"'-~C'--/ __ RESIDENTIAL RESIDENTIAL ADDITION MINOR ( < $10,000.00) TENANT IMPROVEMENT PLAZA CAMINO REAL VILLAGE FAIRE COMPLETE OFFICE BUILDING · OTHER PLANNER 9):Jc_; DATE lZ / z,.Jr1 TI .,, ENGINEER .~¥ DATE <~ . C:\WP51\FILES\BLDG.FRM Rev 11 /15/90 r, City of Carlsbad . 93230 · Fire Department • Bureau of Prevention Plan Review: Requirements Category: Building Plan Check Date of Report: Monday, January 3, 1994 Reviewed by:~ Contact Name Bill Nelson Address Po Box 3842 ----------------- City, State Rancho Santa Fe CA 92067 Bldg. Dept. No. 93-1358 Planning No. Job Name Pacific Snax ----------------- Job Addre~s _2_7_80_L_o_ke_r _______________ _ Ste. or Bldg. No. ____ _ ~ Approved -The item you have submitted for review has been approved. The approval is based on plans; information and/or specifications provided in your submittal; therefore any changes to these items after this date, including field modifica- tions, must be reviewed by this office ·to insure continued conformance·with applicable codes. Please review carefully all comments attached, as failure to comply with instructions in this report can result in suspension of permit to construct or install improvements. D Disapproved -Please see the attached report of deficiencies. Please make corrections to plans or specifications necessary to indicate compliance with applicable codes and standards. Submit corrected plans and/or specifications to this office for review. For Fire Department Use Only Review 1st_· __ 2nd __ _ 3rd. __ _ Other Agency ID CFD Job# __ 93_2_3_0 __ File# ___ _ 2560 Orion Way • Carlsbad, California 92008 • (619) 931-2121