HomeMy WebLinkAbout2784 GATEWAY RD; 101; CB081037; Permit07-11-2008
City of Carlsbad
1635 Faraday Av Carlsbad, CA 92008
Commercial/Industrial Permit Permit No CB081037
Building Inspection Request Line (760) 602-2725
Job Address
Permit Type
Parcel No
Valuation
Occupancy Group
Project Title
2784 GATEWAY RD CBAD St 101
Tl Sub Type
2133001200 Lot#
$126,45500 Construction Type
Reference #
BRESSI SPEC SUITE 3,613 SF
SHELL TO OFFICE
COMM
0
5B
Applicant
HALL STEPHEN
PO BOX 388
CARDIFF CA 92007
760-*533-1915
Status
Applied
Entered By
Plan Approved
Issued
Inspect firea
Plan Check#
ISSUED
06/03/2008
KG
07/11/2008
07/11/2008
Owner
KELLY CAPITAL GROUP INC
406 9TH AVE #309
SAN DIEGO CA 92101
Building Permit
Add'l Building Permit Fee
Plan Check
Add'l Plan Check Fee
Plan Check Discount
Strong Motion Fee
Park Fee
LFM Fee
Bridge Fee
BTD #2 Fee
BTD #3 Fee
Renewal Fee
Add'l Renewal Fee
Other Building Fee
Pot Water Con Fee
Meter Size
Add'l Pot Water Con Fee
Reel Water Con Fee
$686 97 Meter Size
$0 00 Add'l Reel Water Con Fee
$446 53 Meter Fee
$0 00 SDCWA Fee
$0 00 CFD Payoff Fee
$2656 PFF (3105540)
$0 00 PFF (4305540)
$000 License Tax (3104193)
$0 00 License Tax (4304193)
$0 00 Traffic Impact Fee (3105541)
$000 Traffic Impact Fee (4305541)
$0 00 PLUMBING TOTAL
$0 00 ELECTRICAL TOTAL
$000 MECHANICAL TOTAL
$7,702 00 Master Drainage Fee
D1 Sewer Fee
$0 00 Redev Parking Fee
$0 00 Additional Fees
HMP Fee
TOTAL PERMIT FEES
$000
$225 00
$7,18800
$000
$2.301 48
$000
$000
$000
$1,620 00
$000
$4800
$12250
$10650
$000
$2,554 20
$000
$000
99
$23,027 74
Total Fees $23,027 74 Total Payments To Date $23,027 74 Balance Due
oU>LDiNG
$0 00
i>U>-L
«/ IIIN STORAGE
ATTACHED
Inspector
FINAL APPROVAL
Date Clearance
NOTICE Please take NOTICE that Approval ol your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively
referred to as 'fees/exactions' You have 90 days from the date this permit was issued to protest imposition of these fees/exactions If you protest them, you must
follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required .nformation with the City Manager for
processing in accordance with Carlsbad Municipal Code Section 3 32 030 Failure to timely follow that procedure will bsr any subsequent legal action to attack
review, set aside, void, or annul their imposition
You are hereby FURTHER NOTIFIED that your nght to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity
changes nor planning zoning grading or other similar application processing or service fees in connection with this project NOR DOES IT APPLY to any
fees/exactions ol which you have previously been given a NOTICE similar to this or as to which the statute of limitations has oreviouslv otherwise exoired
'' City of Cor.sbod
1635 FaradayAve,Carlsbad CA92008
760-602 2717 / 2718 / 2719
Fax 760-602-8558
Building Permit Application
Plan Check N
Est Value
I DESCRIPTION OF WORK Include Sviiare Feet or Affected 4rea(«)
EXISTING USE PROPOSED USE AIR CONDITIONING FIRE SPRINKLERS
APPLICANT NAME
CONTRACTOR BUS NAME
S^U.i
-jksfe/v . 54e- /.TO
PHONE
So — ."Diexo
ZIP
7M2-C*
EMAIL
ARCH/DESIGNER "NAME & ADDRESS STATEUC a "CtASS"TCIIY BUS UC
ir uty itnrflrjrt prior n> in mamtx, ibo rnuirti Itii uplKanl for such permit to lilt a limd luumtnt dial be 11• - ' ' * '' * -• -' " ' ' ' if hr At ilUpd iiuifiion (if nolauon «,ind Praltunu Code) or dot he n cumpt ihtrefrotn, ud the biui
Workers Compensation Declaration /nereoy affirm underpenany of per/ury one of fne Wtowwig dec/arafwns
und will maintain a certificate of consent to self Insure for workers compensation as provided by Section 3700 of the Labor Code for the performance of the work for when this permit is issued
'l have and will maintain workers' compensation as required by Section 3700 of the Labor Code for the performance of the work for which this permil is issued My workers compensation insurance earner and puticy
number are Insurance Co ,-h r^fti IJ^I CLf\ CjgjPAftl 1^"- Policy No AlC6\31»'a'T:O 'Sil EimaftonDate ? A-/2.00*7
This section need not be completed if Ihe permit is for one hundred dollars (SI00] or less
L7~Certiffcate of Exemption I certify thai in the performance of the work for which this permit is issued I shall not employ any person in any manner so as to become subject to the Workers Compensalron Laws of
California WARNING Failure to secure workers compensation coverage Is unlawful, and shall subject an employer to criminal penalbea and civil fines up to one hundred thousand dollars (S100 000) In
addition to the cost of compensation damages aa provided for in Section 3706 of theJjDfiLCode interest and attorney s fees
^ /y ^7 *• *CI^""*N
JBS CONTRACTOR SIGNATURE /^C^~- /^l/l-*^^ ^~ ~^J DATE
I hereby affirm mal / am exempf torn Contractors License Law far fne fcJIomng reason
O I gs owner of the property or my employees with wages as their sole compensation will do the work and the structure is not intended or offered for sate (Sec 7044 Business and Professions Code The Contractor s
License Law does not apply to art owner of property who builds or improves thereon and who does such work himself or through his own employees provided that such impiovements are not intended or oflered for
sale If however Ihe bidding «improvement is sold within one year of completion Ihe owner builder will have Ihe burden of proving thai he did not build or improve for Ihe purpose of sale)
n I as owner of the property am exclusively contracting with licensed contractors to construct Ihe project (Sec 7044 Business and Professions Code The Contractor's license Law does not apply to an owner ot
property who builds or vnproves (hereon and contracts for such projects with contraclor(s) licensed pursuant to the Contractor's License Law)
n lam exempt undet Section Business and Professions Code for this reason
t I personally plan to provide Ihe major labor and malenals lor construction of the proposed property improvement OYes d No
2 I (have / have not) signed an application for a budding permil for the proposed work
3 I have contacted wilh the following person (firm) to provide Ihe proposed construction (include name address / phone / contractors license number)
4 I plan to provide portions of Ihe work but I have hired the following person to coordinate supervise and provide Ihe major work (include name / address /phone / contractors license number)
5 I will provide some of the work but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone / type of work)
.^PROPERTY OWNER SIGNATURE
Is the applicant or future building occupanl required to submit a business plan acutely hazardous malenals registration form or nsk management and prevention program under Sections 25505 25533 or 25534 of the
Presley Tanner Hazardous Substance Account Act' OYes Q No
Is the applicant or future building occupant required to obtam a permrl from Ihe ar poUon control dislnct or air quality management dslncP a Yes a No
Is Ihe facility to be constructed within 1000 feet of Ihe outer boundary ol a school site' a Yes a No
EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT
I hereby affirm tat there is a construction lending agency for the performance of the work ttiis permit rs issued (Sec 3097 (i) toil Code)
| Lender's Name Lender's Address
Icertjryttiatlhavcreadmeapplicatonandstotetnatme^
ErepresertatrveofflBCtyrfCalsbadtoeiteur^ I ALSO AGREE TO SAVE INDErVWFY AND KEEP HARMLESS THE CITY OF CARLSBAD |
OSHA An OSHA permit s required tar excavators over SV deep and cfeirolrta or ccrisSuaiaidstructuns over 3 stones r height
EXRRATION EvBrypermJssuedbyrfer^ld^OfW
180 (lays Inni tie dale ri such penM oX^th; by^ir^ cr/i^
DATE /* Z
City of Carlsbad
Final Building Inspection
Dept. Building Engineering Planning CMWD St Lite <JF]re7
Plan Check #
Permit #
Project Name
Address
Contact Person PAUL
Sewer Dist CA
CB081037
BRESSI SPEC SUITE 3,613 SF
SHELL TO OFFICE
2784 GATEWAY RD #101
Phone 8589670928
Water Dist CA
Date 08/22/2008
Permit Type Tl
Sub Type COMM
Lot
Inspected
By
s\
Is
Inspected
By
Date
Inspected *2_Approved r Disapproved
Inspected
By
Date
Inspected
Date
Inspected
.Approved
. Approved
Disapproved
Disapproved
Comments
Ed Jd wi/
Gf
City of Carlsbad Bldg Inspection Request
For 08/22/2008
Permit* CB081037
Title BRESSI SPEC SUITE 3,613 SF
Description SHELL TO OFFICE
Inspector Assignment PY
2784 GATEWAY RD
101 Lot
Type Tl Sub Type COMM
Job Address
Suite
Location
ONTRACTOR PACIFIC BUILDING GROUP
Owner KELLY CAPITAL GROUP INC
Remarks
Phone 8589670928
Inspector
Total Time
CD Description
19 Final Structural
29 Final Plumbing
39 Final Electrical
49 Final Mechanical
Requested By PAUL
Entered By JANEAN
Comments/Notices/Holds
Associated PCRs/CVs Original PC#
Inspection History
Date Description
08/14/2008 84 Rough Combo PA PY
07/23/2008 14 Frame/Steel/Bolting/Welding PA PY
07/23/2008 16 Insulation AP PY
07/23/2008 17 Interior Lath/Drywall AP PY
07/23/2008 34 Rough Electric PA PY
07/21/2008 14 Frame/Steel/Bolting/Welding PA MC
07/21/2008 34 Rough Electric PA MC
07/17/2008 22 Sewer/Water Service AP PY
07/17/2008 24 Rough/Topout AP PY
07/16/2008 44 Rough/Ducts/Dampers NR PY
Act Insp Comments
T-BAR
GRAB BAR BACKING AT RESTROOMS
LCP BOX & LIGHT CANS @ RESTROOMS
WALLS & LID FRAME @ RM 06-07 ONLY
WALL ELECTRICAL ONLY, NEED LCP INSTALLED
City of Carlsbad Bldg Inspection Request
For 08/14/2008
Permit* CB081037
Title BRESSI SPEC SUITE 3,613 SF
Description SHELL TO OFFICE
Inspector Assignment PY
Sub Type COMM
2784 GATEWAY RD
101 Lot
Type Tl
Job Address
Suite
Location
ONTRACTOR PACIFIC BUILDING GROUP
Owner KELLY CAPITAL GROUP INC
Remarks ceiling inspection
Phone 8589670928
Inspector
Total Time
.£I
Requested By PAUL
Entered By CHRISTINE
CD Description Act Comments
14 Frame/Steel/Boltmg/Weldmg
24 Rough/Topout
34 Rough Electric
44 Rough/Ducts/Dampers
Comments/Notices/Holds
Associated PCRs/CVs Original PC#
Inspection History
Date Description
07/23/2008 14 Frame/Steel/Bolting/Welding
07/23/2008 16 Insulation
07/23/2008 17 Interior Lath/Drywall
07/23/2008 34 Rough Electric
07/21/2008 14 Frame/Steel/Bolting/Weldmg
07/21/2008 34 Rough Electric
07/17/2008 22 Sewer/Water Service
07/17/2008 24 Rough/Topout
07/16/2008 44 Rough/Ducts/Dampers
Act Insp Comments
PA
AP
AP
PA
PA
PA
AP
AP
NR
PY
PY
PY
PY
MC
MC
PY
PY
PY
GRAB BAR BACKING AT RESTROOMS
LCP BOX & LIGHT CANS @ RESTROOMS
WALLS & LID FRAME @ RM 05-07 ONLY
WALL ELECTRICAL ONLY, NEED LCP INSTALLED
EsGii Corporation
In Partnership with government for <Bmkfmg Safety
DATE June 30, 2008
' 'a JUF
JURISDICTION Carlsbad ~O"~PLAN REVIEWER
a FILE
PLAN CHECK NO 08-1037 SET II
PROJECT ADDRESS 2784 Gateway Road
PROJECT NAME Spec Suite
[ | The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes
The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff
The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted fora complete recheck
The check list transmitted herewith is for your information The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck
The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person
The applicant's copy of the check list has been sent to
Esgil Corporation staff did not advise the applicant that the plan check has been completed
Esgil Corporation staff did advise the applicant that the plan check has been completed
Person contacted Stephen Hall Telephone #
Date contacted (by ) Fax #
Mail Telephone Fax In Person
REMARKS OK to issue with the designer signing each Sheet of plans and the accessibility
certification on the Cover Sheet of the plans
[X] REMARKS OK to issue with applicant replacing the "A" Sheet in set I with the "A" Sheets
marked set II Received one set only
By Bryan Zuppiger Enclosures
Esgil Corporation
D GA D MB D EJ D PC 06/23/2008
trnsmtl dot
9320 Chesapeake Drive, Suite 208 * San Diego, California 92123 *• (858)560-1468 4 Fax (858) 560-1576
EsGil Corporation
In (PartnersKip iintK government f or (BuiCfmg Safety
DATE June 12, 2008
JURISDICTION Carlsbad Q PLAN REVIEWERa FILE
PLAN CHECK NO 08-1O37 SET I
PROJECT ADDRESS 2784 Gateway Road
PROJECT NAME Spec Suite
I | The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes
^] The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff
I | The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck
[Xl The check list transmitted herewith is for your information The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck
I | The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person
The applicant's copy of the check list has been sent to
Stephen Hall
P O Box 388
Cardiff, CA 92007
I | Esgil Corporation staff did not advise the applicant that the plan check has been completed
[Xj Esgil Corporation staff did advise the applicant that the plan check has been completed
Person contacted Stephen Hall Telephone # 760 533 1 91 5
Date contacted ^/y ?/^byV/^ ) Fax # 760 943 1 9 1 5
MailK Telephone Fa^ In Person
REMARKS
By Bryan Zuppiger Enclosures
Esgil Corporationn GA n MB n EJ n PC 06/05/2008
trnsmtl dot
9320 Chesapeake Drive, Suite 20S * San Diego, California 92123 4 (858)560-1468 +• Fax (858) 560-1576
Carlsbad OS-1037
June 12,2008
PLAN REVIEW CORRECTION LIST
TENANT IMPROVEMENTS
PLAN CHECK NO O8-1037
OCCUPANCY B
TYPE OF CONSTRUCTION VN?
SPRINKLERS'? yes
DATE PLANS RECEIVED BY
JURISDICTION
DATE INITIAL PLAN REVIEW
COMPLETED June 12, 2008
JURISDICTION Carlsbad
USE office
ACTUAL AREA 3613 fta
OCCUPANT LOAD 36
DATE PLANS RECEIVED BY
ESGIL CORPORATION 06/05/2008
PLAN REVIEWER Bryan Zuppiger
This plan review is limited to the technical requirements contained in the International Building Code,
Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws
regulating energy conservation, noise attenuation and access for the disabled This plan review is
based on regulations enforced by the Building Department You may have other corrections based on
laws and ordinances enforced by the Planning Department, Engineering Department, Fire
Department or other departments Clearance from those departments may be required prior to the
issuance of a building permit
Code sections cited are based on the 2007 CBC that adopts the 2006 IBC
The following items listed need clarification, modification or change All items must be satisfied before
the plans will be in conformance with the cited codes and regulations Per IBC Section 1054 of the
2006 International Building Code, the approval of the plans does not permit the violation of any state,
county or city law
To speed up the recheck process, please note on this list (or a copy) where each correction
item has been addressed, i e.. plan sheet number, specification section, etc. Be sure to
enclose the marked up list when you submit the revised plans
Carlsbad O8-1O37
June 12,20O8
• PLANS
1 Please make all corrections on the original tracings, as requested in the correction list Submit
three sets of plans for commercial/industrial projects (two sets of plans for residential projects)
For expeditious processing, corrected sets can be submitted in one of two ways
a) Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad
Building Department, 1635 Faraday Avenue, Carlsbad, CA 92008, and (760) 602-2700
The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering
and Fire Departments
b) Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320
Chesapeake Drive, Suite 208, San Diego, CA 92123, and (858) 560-1468 Deliver all
remaining sets of plans and calculations/reports directly to the City of Carlsbad Building
Department for routing to their Planning, Engineering and Fire Departments
NOTE Plans that are submitted directly to EsGil Corporation only will not be reviewed by
the City Planning, Engineering and Fire Departments until review by EsGil Corporation is
complete
2 Provide the names, addresses and telephone numbers of the owner and the responsible
design professionals on the Title Sheet CBC Section 106 1 1
3 Provide a section view of all new interior partitions that is referenced to the floor plan Show,
a) Method of attaching top and bottom plates to structure (NOTE Top of partition must be
secured to roof or floor framing, unless suspended ceiling has been designed for
partition lateral load) Please not that the diagonal wall brace spacing can not
exceed 4' on center.
4 Note on plan that suspended ceilings shall comply with ASTM C 635 & ASTM C 636
5 Please note that suspended ceilings in Seismic Design Categories D, E & F per ASCE 7-05
Section 135621 shall have the following,
a) A heavy duty T-bar system shall be used
b) The width of the perimeter supporting closure angle shall be no less than 2" In each
orthogonal horizontal direction one end of the ceiling grid shall be attached to the
closure angle The other end in each horizontal direction shall have a %" clearance from
the wall and shall rest upon and be free to slide on a closure angle
c) For ceiling areas exceeding 2500 ft2 a seismic separation joint or full height partition that
breaks the ceiling up into areas not exceeding 2500 ft2 shall be provided unless
structural analysis performed by an engineer or architect licensed by the State of
California of the ceiling bracing system Please see ASCE 7-05 Section 13 5 6 2 1 (d) for
the analysis criteria
6 The HVAC unit weight(s) exceed 400lbs an analysis of the existing roof framing from an
engineer or architect licensed by the State of California is required ASCE 1314
7 Please sign the accessibility certifications on Sheet AO 1
Carlsbad O8-1O37
June 12,2OO8
The person responsible for their preparation must sign all final sheets of plans (California
Business and Professions Code)
*
Final structural plans, specifications and calculations must be signed and sealed by the
engineer or architect licensed by the State of California who is responsible for their
preparation Please specify the expiration date of license (California Business and Professions
Code)
To speed up the review process, note on this list (or a copy) where each correction item has
been addressed, i e , plan sheet, note or detail number, calculation page, etc
The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive,
Suite 208, San Diego, California 92123, telephone number of 858/560-1468, to perform the
plan review for your project If you have any questions regarding these plan review items,
please contact Bryan Zuppiger at Esgil Corporation Thank you
Carlsbad O8-1O37
June 12, 2O08
VALUATION AND PLAN CHECK FEE
JURISDICTION Carlsbad PLAN CHECK NO O8-1O37
PREPARED BY Bryan Zuppiger DATE June 12, 20O8
BUILDING ADDRESS 2784 Gateway Road
BUILDING OCCUPANCY B TYPE OF CONSTRUCTION VN
BUILDING
PORTION
ti
Air Conditioning
Fire Sprinklers
TOTAL VALUE
Jurisdiction Code
Rlria Permit Fee bv OrHina
AREA
(Sq Ft)
3613
cb
Valuation
Multiplier
3437
By Ordinance
nrp ! ^
Reg
Mod
VALUE ($)
124,179
124,179
$680 25
PlanJTheck Feeby Ordinance
Type of Review \2
D Repetitive Fee
~"!~^~| Repeats
Complete Review
D Other
r-1 Hourly
D Structural Only
Hour*
$442 16
Esgil Plan Review Fee $38094
Comments
macvalue doc
J'City of Carlsbad
Public Works w Eng i neeri n g
BUILDING PLANCHECK CHECKLIST
DATE
BUILDINGADD^ESS
PROJECT DESCRIPTION
ASSESSOR'S PARCEL NUMBER
PLANCHECK NO CBOft
/P/fj
ENGINEERING DEPARTMENT
APPROVAL
The item you have submitted for review has been
approved The approval is based on plans,
information and/or specifications provided in your
submittal therefore any changes to these items after
this date, including field modifications, must be
reviewed by this office to insure continued
conformance with applicable codes Please review
carefully all comments attached, as failure to comply
with instructions in this report can result in
suspension of permit to build
D A Right-of-Way permit is required prior to
construction of the following improvements
EST VALUE
DENIAL
Please seeXthe/attached report of deficiencies
marked with 6^ Make necessary corrections to plans
or specifications for compliance with applicable
codes and standards Submit corrected plans and/or
specifications to this office for review
Date
Date
Date
FOR OFFICIAL USE ONLY
ENGINEERING AUTHORIZATION TO ISSUE BUILDING PERMIT
~^~~ ~ Date =£=
TS
D Dedication Application
D Dedication Checklist
D Improvement Application
D Improvement Checklist
D Neighborhood Improvement Agreement
D Grading Permit Application
D Grading Submittal Checklist
D Right-of-Way Permit Application
rj Right-of-Way Permit Submittal Checklist
and Information Sheet
D Storm water Applicability Checklist
ENGINEERING DEPT CONTACT PERSON
Name JOANNE JUCHNIEWICZ
City of Carlsbad
Address 1635 Faraday Avenue Carlsbad, CA 92008
Phone (760) 602-2775
CFD INFORMATION
Parcel Map No
Lots
Recordation
Carlsbad Tract
Carlsbad CA 9200^-7314 • (76O) 602-2720 • FAX (76O) 602«09<02
RD3
D
BUILDING PLANCHECK CHECKLIST
SITE PLAN
1 Provide a fully dimensioned site plan drawn to scale Show
A North Arrow
B Existing & Proposed Structures
C Existing Street Improvements
D Property Lines
E Easements
Right-of-Way Width & Adjacent Streets
Driveway widths
Existing or proposed sewer lateral
Existing or proposed water service
D D 2 Show on site plan
A Drainage Patterns
1 Building pad surface drainage must maintain a minimum slope of one
percent towards an adjoining street or an approved drainage course
2 ADD THE FOLLOWING NOTE "Finish grade will provide a minimum positive
drainage of 2% to swale 5' away from building "
B Existing & Proposed Slopes and Topography
C Size, type, location, alignment of existing or proposed sewer and water service (s)
that serves the project Each unit requires a separate service, however, second
dwelling units and apartment complexes are an exception
Sewer and water laterals should not be located within proposed driveways, per
standards
3 Include on title sheet
Site address -Stef*>\
ssor's Parcel Number
Legal Description \ S> Ltrlr <4- CT O f ~° 7
For commercial/industrial buildings and tenant improvement projects, include
total building square footage with the square footage for each different use,
existing sewer permits showing square footage of different uses (manufacturing,
warehouse, office, etc) previously approved
EXISTING PERMIT NUMBER DESCRIPTION
F \BUILDING PUkNCHECK CKLST FORM doc
BUILDING PLANCHECK CHECKLIST
3KU DISCRETIONARY APPROVAL COMPLIANCE
D D 4a Project does not comply with the following Engineering Conditions of approval for
Project No
D D CH 4b All conditions are in compliance Date
DEDICATION REQUIREMENTS
D 5 Dedication for all street Rights-of-Way adjacent to the building site and any storm
drain or utility easements on the building site is required for all new buildings and
for remodels with a value at or exceeding $ 17.000 . pursuant to Carlsbad
Municipal Code Section 18 40 030
Dedication required as follows
Dedication required Please have a registered Civil Engineer or Land Surveyor
prepare the appropriate legal description together with an 8 Ya" x 11" plat map and
submit with a title report All easement documents must be approved and signed
by owner(s) prior to issuance of Building Permit Attached please find an
application form and submittal checklist for the dedication process Submit the
completed application form with the required checklist items and fees to the
Engineering Department in person Applications will not be accept by mail or fax
Dedication completed by Date
IMPROVEMENT REQUIREMENTS
LU D D 6a All needed public improvements upon and adjacent to the building site must be '
constructed at time of building construction whenever the value of the
construction exceeds $ 82.000 . pursuant to Carlsbad Municipal Code Section
1840040
Public improvements required as follows
Attached please find an application form and submittal checklist for the public
improvement requirements A registered Civil Engineer must prepare the
appropriate improvement plans and submit them together with the requirements
on the attached checklist to the Engmeenng Department through a separate plan
check process The completed application form and the requirements on the
F (BUILDING PLANCHECK CKLST FORM doc
. ST 2ND 3RD
BUILDING PLANCHECK CHECKLIST
checklist must be submitted in person Applications by mail or fax are not
accepted Improvement plans must be approved, appropriate securities posted
and fees paid prior to issuance of building permit
Improvement Plans signed by Date
D D D 6b Construction of the public improvements may be deferred pursuant to Carlsbad
Municipal Code Section 1840 Please submit a recent property title report or
current grant deed on the property and processing fee of $430 so we may
prepare the necessary Neighborhood Improvement Agreement This agreement
must be signed, notarized and approved by the City prior to issuance of a
Building permit
Future public improvements required as follows
D D D 6c Enclosed please find your Neighborhood Improvement Agreement Please return
agreement signed and notarized to the Engineering Department
Neighborhood Improvement
Agreement completed by
Date
6d No Public Improvements required SPECIAL NOTE Damaged or defective
improvements found adiacent to building site must be repaired to the satisfaction
of the City Inspector prior to occupancy
GRADING PERMIT REQUIREMENTS
The conditions that invoke the need for a grading permit are found in Section
15 16 010 of the Municipal Code
CD D D 7a Inadequate information available on Site Plan to make a determination on grading
requirements Include accurate grading quantities in cubic yards (cut, fill, import,
export and remedial) This information must be included on the plans.
D D D 7b Grading Permit required A separate grading plan prepared by a registered Civil
Engineer must be submitted together with the completed application form
attached NOTE The Grading Permit must be issued and rough grading
approval obtained prior to issuance of a Building Permit
Grading Inspector sign off by Date
D D 7c Graded Pad Certification required (Note Pad certification may be required even
if a grading permit is not required )
F \8UILDING PLANCHECK CKLST FORM doc
BUILDING PLANCHECK CHECKLIST
,ST RD3
D
D
7d No Grading Permit required
7e If grading is not required, write "No Grading" on plot plan
MISCELLANEOUS PERMITS
D 8
D
D D
D D
A RIGHT-OF-WAY PERMIT is required to do work in City Right-of-Way and/or
private work adjacent to the public Right-of-Way Types of work include, but are
not limited to street improvements, tree trimming, driveway construction, tying
into public storm drain, sewer and water utilities
Right-of-Way permit required for _
INDUSTRIAL WASTE PERMIT If your facility is located in the City of Carlsbad
sewer service area, you need to contact the Carlsbad Municipal Water District,
located at 5950 El Cammo Real, Carlsbad, CA 92008 District personnel can
provide forms and assistance, and will check to see if your business enterprise is
on the EWA Exempt List You may telephone (760) 438-2722, extension 7138,
for assistance
Industrial Waste permit accepted by
Date
10 NPDES PERMIT
Complies with the City's requirements of the National Pollutant Discharge
Elimination System (NPDES) permit The applicant shall provide best
management practices to reduce surface pollutants to an acceptable level prior to
discharge to sensitive areas Plans for such improvements shall be approved by
the City Engineer prior to issuance of grading or building permit, whichever
occurs first
10 a STORM WATER COMPLIANCE FORM
Q Requires PSWP (project storm water permit) #
Q Tier I/Tier fl (Requires SWPPP) - Please complete attached forms
.3 Exempt - Please complete attached exemption form
Required fees are attached
'Q No fees required
F \BUILOIN3 PIANCHECK CKLST FORM doc
BUILDING PLANCHECK CHECKLIST
WATER METER REVIEW
12a Domestic (potable) Use
Ensure that the meter proposed by the owner/developer is not oversized
Oversized meters are inaccurate during low-flow conditions If it is oversized, for
the life of the meter, the City will not accurately bill the owner for the water used
• All single family dwelling units received "standard" 1" service with 5/8" service
If owner/developer proposes a size other than the "standard", then
owner/developer must provide potable water demand calculations, which
include total fixture counts and maximum water demand in gallons per minute
(gpm) A typical fixture count and water demand worksheet is attached Once
the gpm is provided, check against the "meter sizing schedule" to verify the
anticipated meter size for the unit
Maximum service and meter size is a 2" service with a 2" meter
If a developer is proposing a meter greater than 2", suggest the installation of
multiple 2" services as needed to provide the anticipated demand (manifolds
are considered on case by case basis to limit multiple trenching into the
street)
Irrigation Use (where recycled water is not available)
All irrigation meters must be sized via irrigation calculations (in gpm) prior to
approval The developer must provide these calculations Please follow these
guidelines
1 If the project is a newer development (newer than 1998), check the recent
improvement plans and observe if the new irrigation service is reflected on
the improvement sheets If so, at the water meter station, the demand in
gpm may be listed there Irrigation services are listed with a circled T,
and potable water is typically a circled "W" The irrigation service should
look like
o^STA1+00 Install 2" service and
5 meter (estimated 100 gpm)
If the improvement plans do not list the irrigation meter and the
service/meter will be installed via another instrument such as the building
plans or grading plans (w/ a right of way permit of course), then the
applicant must provide irrigation calculations for estimated worst-case
irrigation demand (largest zone with the farthest reach) Typically, Larry
Black has already reviewed this if landscape plans have been prepared,
but the applicant must provide the calculations to you for your use Once
you have received a good example of irrigation calculations, keep a set for
your reference In general the calculations will include
Hydraulic grade line
Elevation at point of connection (POC)
Pressure at POC in pounds per square inch (PSI)
Worse case zone (largest, farthest away from valve
Total Sprinkler heads listed (with gpm use per head)
Include a 10% residual pressure at point of connection
F \BUILDING PLANCHECK CKLST FORM HOC
BUILDING PLANCHECK CHECKLIST
3 In general, all major sloped areas of a subdivision/project are to be
irrigated via separate irrigation meters (unless the project is only SFD with
no HOA) As long as the project is located within the City recycled water
service boundary, the City intends on switching these irrigation
services/meters to a new recycled water line in the future
D D 12c Irrigation Use (where recycled water is available)
1 Recycled water meters are sized the same as the irrigation meter above
2 If a project fronts a street with recycled water, then they should be
connecting to this line to irrigate slopes within the development For
subdivisions, this should have been identified, and implemented on the
improvement plans Installing recycled water meters is a benefit for the
applicant since they are exempt from paying the San Diego County Water
Capacity fees However, if they front a street which the recycled water is
there, but is not live (sometimes they are charged with potable water until
recycled water is available), then the applicant must pay the San Diego
Water Capacity Charge If within three years, the recycled water line is
charged with recycled water by CMWD, then the applicant can apply for a
refund to the San Diego County Water Authority (SDCWA) for a refund
However, let the applicant know that we cannot guarantee the refund, and
they must deal with the SDCWA for this
D D D 13 Additional Comments:
F BUILDING PLANCHECK CKLST FORM doc
ENGINEERING DEPARTMENT
FEE CALCULATION WORKSHEET
itimate based on unconfirmed information from applicant
Calculation based on building plancheck plan submittal
3*'*0
&*JUL-
Address
Prepared by rcr
EDU CALCULATIONS: Lis
Types of US£!~ <*V°
Types of Use
APT CALCULATIONS: List
f $&'€^\y»_1eJkr e>*A S\.Types of Use w
Types of Use
Date £//0/d£ Checked byif
it types^md square footages for all uses
-*•<#- fZ*'-t>v-loS JSq Ft /Units
Sq Ft /Units
types and square footages for all uses
~&BJ$T <Kv~ Cfi-^e-S)
Sq Ft /Units
Sq Ft /Units
Date
1
EDU's
EDU's
. ADT's
ADT's
1 ^
Sf
FEES REQUIRED-
WITHIN CFD CITES (no bridge & thoroughfare fee in Dtstnct #1, reduced Traffic Impact Fee)
Ifl PARK-IN-LIEU FEE PARK AREA & #
DNO
FEE/UNIT X NO UNITS =$
TRAFFIC IMPACT FEE
ADT's/UNITS uHt
BRIDGE AND THOROUGHFARE FEE
ADT's/UNITS
) FACILITIES MANAGEMENT FEE
/ UNIT/SO FT
5 SEWER FEE
EDU's 1 . J^\
X FEE/ADT 3O
(DIST #1 DIST #2
X FEE/ADT
ZONE
X FEE/SO FT /UNIT
X FEE/EDU /05>8
r
t
DIST #3 )
=S 0
=$ fflT
* 1 3W6
BENEFIT AREA .
EDU'S / .
/T
6 SEWER LATERAL ($2,500)
7 DRAINAGE FEES PLDA
ACRES
8 POTABLE WATER FEES
UNITS CODE CONNECTION FEEJ_ D/ 770;?
X FEE/EDU.
HIGH.
FEE/AC _
=$=$
/LOW
=$_
METER FEE SDCWA FEE DCWA FEE
F \FEE CALCULATION WORKSHEET doc
1of2
Rev 7/14/00
PLANNING DEPARTMENT
BUILDING PLAN CHECK REVIEW CHECKLIST
Plan Check No CB081Q37 Address 2784 Gateway Rd
Planner Deborah'Milarri Phone (760) 602- 461~9
APN 213-300-12
Type of Project & Use JJ Net Project Density DU/AC
Zoning P-M General Plan PJ Facilities Management Zone 17
CFD (in/out) #_Date of participation Remaining net dev acres
Circle One (For non-residential development Type of land used created by this permit
D
D
DD
D
Legend ^ Item Complete
Environmental Review Required
DATE OF COMPLETION _
Item Incomplete - Needs your action
YES D NO Q TYPE
Compliance with conditions of approval7 If not, state conditions which require action
Conditions of Approval _
YES D NO D TYPE _Discretionary Action Required
APPROVAL/RESO NO DATE
PROJECT NO
OTHER RELATED CASES
Compliance with conditions or approval? If not, state conditions which require action
Conditions of Approval
Coastal Zone Assessment/Compliance
Project site located in Coastal Zone? YES Q NO Q
CA Coastal Commission Authority? YES Q NO Q
If California Coastal Commission Authority Contact them at - 7575 Metropolitan Drive, Suite 103,
San Diego, CA 92108-4402, (619) 767-2370
Determine status (Coastal Permit Required or Exempt)
Habitat Management Plan
Data Entry Completed? YES Q NO D
If property has Habitat Type identified in Table 11 of HMP, complete HMP Permit application and
assess fees in Permits Plus
(A/P/Ds, Activity Maintenance, enter CB#, toolbar, Screens, HMP Fees, Enter Acres of Habitat Type
impacted/taken, UPDATE')
Inclusionary Housing Fee required YES D NO D
(Effective date of Inclusionary Housing Ordinance - May 21,1993 )
Data Entry Completed? YES D NOD
(A/P/Ds, Activity Maintenance, enter CB#, toolbar, Screens, Housing Fees, Construct Housing Y/N,
Enter Fee, UPDATE')
H \ADMIN\Ternplate\Buildmg Plancheck Review Checklist doc Rev 4/08
Site Plan
ODD Provide a fully dimensional site plan drawn to scale Show North arrow, property lines, easements,
existing and proposed structures, streets, existing street improvements, right-of-way width,
dimensional setbacks and existing topographical lines (including all side and rear yard slopes)
Provide legal description of property and assessor's parcel number
an
an
an
an
n n
nn
nn
Policy 44 - Neighborhood Architectural Design Guidelines
1 Applicability YES D NO D
2
. V
Project complies YES D NOQ
Zoning
1 Setbacks
Front
Interior Side
Street Side
Rear
Top of slope
Required.
Required.
Required.
Required
Required.
2 Accessory structure setbacks
Front Required.
Interior Side Required.
Street Side Required.
Rear Required.
Structure separation Required.
3 Lot Coverage Required.
4 Height Required.
Shown.
Shown
Shown.
Shown.
Shown
Shown
. Shown.
. Shown.
Shown.
Shown.
Shown.
Shown
\
5 Parking Spaces Required 81 Shown 81.
(breakdown by uses for commercial and industrial projects required)
Residential Guest Spaces Required Shown
Additional Comments Correction #1 Please show how new roof-mounted equipment will be
screened Include a side elevation with location and height of equipment and a sight line from 500'
feet away that doesn't intersect with the equipment See attached handout for example Correction
#2 Please change the APN to 213-300-12 The one on the plan set is expired
OK TO ISSUE AND ENTERED APPROVAL INTO COMPUTER DATE
H \ADMIN\Template\Building Plancheck Review Checklist doc Rev 4/08
Carlsbad Fire Department
Plan Review Reqint ements Category TI COMM
Date of Report 06-16-2008 Reviewed by
Name HALL STEPHEN
Address
P O BOX 388
CARDIFF CA
92007
Pei mil # CB081037
Job Name BRESSI SPEC SUIT E 3 613 SF
Job Address 2784 GATEWAY RD CBAD St 101
INCOMPLETE The item you have submitted tor review is incomplete At this time, this office cannot
adequately conduct a review to determine compliance with the applicable codes and/oi standards Please review
carefully all comments attached Please resubmit the necessary plans and/or specifications, with changes "clouded"
to this office for review and approval
Conditions
Cond CON0002856
THIS PROJECT HAS BEEN REVIEWED AND APPROVED FOR THE PURPOSES OF ISSUEANCC OF A
BUILDING PERMIT
THIS APPROVAL IS SUBJECT TO FIELD INSPECTIONS. ANY REQUIRED FFSTS, FIRE DEPARTMENT
NO I AT IONS.
CONDITIONS IN CORRESPONDENCE AND COMPIIANCE WFIH ALL APPLICABLE CODES AND
REGULATIONS
THIS APPROVAL SHALL NOT BE HELD TO PERMIT OR APPROVE ANY VIOLATION OF THE LAW
' Entry 06/16/2008 By cwong Action
ACORD- CERTIFICATE OF LIABILITY INSURANCE 3/1/2009 "^SoT
—ODUCER Lockton. Companies LLC L Los Angeles
725 S Figueroa Street 35th Fl
CA License #OF1 5767Los Angeles CA 9001 7(213)689-0065
INSURED pacrfic Building Group
1068619 9752 Aspen Creek Ct Ste 150San Diego CA 92126
i
THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATIONONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATEHOLDER THIS CERTIFICATE DOES NOT AMEND, EXTEND ORALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW
INSURERS AFFORDING COVERAGE
INSURER A Old Republic General Ins Corporation
INSURER B American Guarantee and Liab Ins Co
INSURER C
INSURER D
INSURER E
NAIC#
24139
26247
COVERAGES rAL-BUUl yj INSURERfSl AUTHORIZED REPRESENTATIVE OR PRODUCER AND THE CERTIFICATE HOLDER.
THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED NOTWITHSTANDING
ANY REQUIREMENT TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR
MAY PERTAIN THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS EXCLUSIONS AND CONDITIONS OF SUCH
POLICIES AGGREGATE LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS
INSRLTR
A
A
B
A
ADOLMSKD
X
TYPE OF INSURANCE
GENERAL LIABILITY
x_
x"
COMMERCIAL GENERAL UABILITY
1 CLAIMS MADE [X| OCCUR
$10 000 Deductible
GESTL AGGREGATE UMIT APPLIES PERni — IPRO- I — |POLICY 1 1 JECT 1 [LOG
AU
X
X
X
X
X
OMOBILE LIABILITY
ANY AUTO
ALL OWNED AUTOS
SCHEDULED AUTOS
HIRED AUTOS
NON-OWNED AUTOS
$1 OOOCompDed
$ 1000 Coll Ded
GARAGE LIABILITY
__j ANY AUTO
EXCESS/UMBRELLA UABILITY
X| OCCUR | | CLAIMS MADE
1 1 UMBRELLA
H DEDUCTIBLE LJ FORM
| RETENTION I
WORKERS COMPENSATION AND
EMPLOYERS LIABILITY
ANY PROPHETORIPARTNER/EXECUTrvEOFFICER/MEMBER EXCLUDED?
II ya oncflM under VISPECIAL PROVISIONS Mow JN 0
OTHER
POLICY NUMBER
A1CG36840802
A1CA36840802
NOT APPLICABLE
AUC591 894902
A1CW36840804
POLICY EFFECTIVEDATE(M*WJD/YY)
3/1/2008
3/1/2008
3/1/2008
3/1/2008
POLICY EXPIRATIONDATE (MWDO/YY)
3/1/2009
3/1/2009
3/1/2009
3/1/2009
UMTTS
EACH OCCURRENCE
DAMAGE TO RENTEDPREMISES (Ea ocojrencet
MED EXP (Any one person)
PERSONAL & ADV INJURY
GENERAL AGGREGATE
PRODUCTS COMP/OPAGG
COMBINED SINGLE UMIT
(Ea accident)
BODILY INJURY
(Per person)
BODILY INJURY
(Pfir BoodBfit)
PROPERTY DAMAGE
(Per accident)
AUTO ONLY EA ACCIDENT
OTHER THAN EAACC
AUTO ONLY AGG
EACH OCCURRENCE
AGGREGATE
Vl WCSTATU- I OTH•*• 1 TORY LIMITS 1 6R
E L EACH ACCIDENT
EL DISEASE EA EMPLOYEE
E L DISEASE POLICY LIMIT
* 1 000 000
* 100000
s 5000
* 1 000 000
$ 2000000
» 2000000
* 1 000 000
* xxxxxxx
* xxxxxxx
* xxxxxxx
$ xxxxxxx
i XXXXXXX
j XXXXXXX
j 2000000
j 2000000
j XXXXXXX
$ xxxxxxx
j XXXXXXX
s 1 000 000
j I 000 000
s 1 000 000
DESCRIPTION OF OPERATONS/LOCATIONSfVEHICLES/EXCLUSIONS ADDED BY ENDORSEMENT/SPECIAL PROVISIONS
RE Job# 4-07-OOS6 Callaway Parking Structure 2180 Rutherford Rd Carlsbad CA92130 The City of Carlsbad is an Additional Insured(s) to the extent
provided by the policy language or endorsement issued or approved by the insurance earner
CERTIFICATE HOLDER
3441634
City of Carlsbad
1635 Faraday
Carlsbad CA 92008
I i
ACORD 25 (2001/08)
CANCELLATION [M99628]
SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION
DATE THEREOF THE ISSUING INSURER WILL ENDEAVOR TO MAIL 30 DAYS WRITTEN
NOTICE TO THE CERTIFICATE HOLDER NAMED TO THE LEFT BUT FAILURE TO DO SO SHALL
IMPOSE NO OBLIGATION OR LIABILITY OF ANY KIND UPON THE INSURER, ITS AGENTS OR
REPRESENTATIVES
AUTHORIZED f
ny thit cntifK** comet to « ACORD CORPORATION 1988
DWG 43S-3A
2 OF 8
^?;••
•A--y 1^ -*;3h .e>;
S3 ;
t
•;~ --- ^vjsoww-"-'"" ij
i *t "Mf-< ••»,t j i*.^ 1 '^>-"*, ^,,-u • • :IIIIIIHM 11 ., • /.,
•i
/' i.^-^^,-^.:.. -;|
•>-f> • ("nTT7""" i'
, .. n!
' !•« *i»i •"' il! »'l! »S| -•i '{ B*! rii
.11tii\.--S1! '
'isdi^ULj !I Sl'fei'/Fi r-l;N' S^-'ll-'-
Mi^Sv^^PfX^-- |
Hi fi.'Jsi »;;*••-''
?H'l §S! "'
r i!
Li. r;;.'i,. *t\
l-i;l
:!il..
%t- ^
I i !|f 5%?.,is sii? '-a d
.*:'
i^:RNi i?« V f- O-?.ii! %f ^m^ ^%& »!- >M » ;i i X- - / / \ J; v. ii 5l s* & t!) Mi i II '- §. A ' h .1 5 | J j !J 3
L<F i!- ,g ^ s
=•"• ! !>:« S
?J I:» I"»ljt 3S
^ (>•} ?• ^* s'
I I i S
i.Ai *' ii^s &1 ' r. i ir1
•,-iN li
n
r^-r
09-04-2008
Job Address
Permit Type
Parcel No
Valuation
Reference #
PC#
Project Title
City of Carlsbad
1635 Faraday Av Carlsbad, CA 92008
Plan Check Revision Permit No PCR08090
Building Inspection Request Line (760) 602-2725
2784 GATEWAY RD CBAD St 101
PCR
2133001200 Lot*
$0 00 Construction Type
CB081037
BRESSI SPEC SUITE- MECHANICAL
REVISIONS
0
NEW
Status
Applied
Entered By
Plan Approved
Issued
Inspec* Area
Applicant
CHRIS ANDREWS
STE 902
9474 CHESAPEAKE DR 92123
858 279 4700
Owner
KELLY CAPITAL GROUP INC
406 9TH AVE #309
SAN DIEGO CA 92101
ISSUED
08/22/2008
LSM
09/04/2008
09/04/2008
Plan Check Revision Fee
Additional Fees
$18000
$000
Total Fees $18000 Total Payments To Date $18000 Balance Due $000
Inspector
FINAL APPROVAL
Date Clearance
NOTICE Please take NOTICE trjbf approval of your project includes the Imposition of fees dedications reservations ir other exactions hereafter collectively
referred to as fees/exactions Yeu have 90 days from the date this permit was issued to protest imposition of these fees/exactions If you protest them you must
follow the protest procedures set forth in Government Code Section 66020(a) and file the protest and any other required nformation with the City Manager for
processing in accordance with Carlsbad Municipal Code Section 3 32 030 Failure to timely follow that procedure will bar any subsequent legal action to attack
review set aside void or annul their imposition
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity
changes nor planning zoning grading or other similar application processing or service fees in connection with this prop"! NOR DOES IT APPLY to any
fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired
EsGil Corporation
In Partnership with government for (Bwbfing Safety
DATE August 27, 2008 , _ OAEELJCANT
JURISDICTION Carlsbad a PLAN REVIEWER
a FILE
PLAN CHECK NO O8-1037 REV SET I
PROJECT ADDRESS 2784 Gateway Road
PROJECT NAME Spec Suite
The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes
The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff
The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck
The check list transmitted herewith is for your information The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck
The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person
The applicant's copy of the check list has been sent to
Esgil Corporation staff did not advise the applicant that the plan check has been completed
Esgil Corporation staff did advise the applicant that the plan check has been completed
Person contacted Telephone #
Date contacted (by ) Fax #
Mail Telephone Fax In Person
2<J REMARKS Reviewed Sheets MO 1, MO 4, MO 5, MO 6, M2 1, M2 2 & M5 1 only
By Bryan Zuppiger Enclosures Original Approved Plans
Esgil Corporation
GA D MB D EJ D PC 08/26/2008
trnsmtl dot
9320 Chesapeake Drive, Suite 208 * San Diego, California 92123 ^ (858)560-1468 ^ Fax (858) 560-1576
Carlsbad O8-1O37 REV
August 27, 2O08
VALUATION AND PLAN CHECK FEE
JURISDICTION Carlsbad
PREPARED BY Bryan Zuppiger
BUILDING ADDRESS 2784 Gateway Road
BUILDING OCCUPANCY B
PLAN CHECK NO 08-1037 REV
DATE August 27, 2008
TYPE OF CONSTRUCTION VN
BUILDING
PORTION
ti
Air Conditioning
Fire Sprinklers
TOTAL VALUE
Jurisdiction Code
AREA
( Sq Ft )
revision
cb
Valuation
Multiplier
By Ordinance
Reg
Mod
VALUE ($)
Bldg Permit Fee by Ordinance
Plan Check Fee by Ordinance
Type of Review
I I Repetitive Fee~^n Repeats
$18000
Complete Review
D Other
m Hourly
Structural Only
1 5 Hours *
Esgil Plan Review Fee $144 00
* Based on hourly rate
Comments
macvalue doc
City of Carlsbad
Plan Check Revision No
Project Address £1**+
Building Department
Original Plan Check No Q&OTr
lOi
Address
Business at this address
General Scope of Work
Original plans prepared by an architect or engineer, revisions must be signed & stamped by that person
1 Elements revised
Plans Calculations Soils D Energy D Other
2
Describe revisions m detail
cV*-wv«L u o v V s N*^ o vle. s/2/s*. i «vi /\ I
u>J v, 4-S
mo. 1 rwc).3 mo.«4 ^n «r
pf\O. ix? ^<5?. 1 PO p.^ rw tS" \
3
List page(s) where
each revision is
shown
4
List revised sheets
that replace
existing sheets
5 Does this revision, many way, alter the exterior of the project? Q Yes pel No
O Does this revision add ANY new floor area(s)? Q Yes ^ No
7 Does this revision affect any fire related issues? Q Yes § No
8 Is this a complete set th^f replac^st^origmal permitted set? ffi Yes Q No
163 5 Faraday Avenue Carlsbad CA 92008 Phone 760-602-2717/2718/2719/7541 Fax 760-602-8558
o:*&5 §5 015 |K cc KiiS&lsgiQpsSSoSjCO O CL CO CL IU UJ tZcoa.uiu.iiOI*! &5-TO FROAPPLICANT APPCM
o>
2z<
oLU
LLJ
5
Cfl
L
^O
$^
LU >tr LLIm o:
r
r^
O
(
0°
<0
^
o
€
>
o€
m"
o
^-kt^s
>0
^
—
(0&
A
d
^
^0.
^\^y
*-^i^§\J
|
Q)
)/—*
£^\
0<v
-t'4^p
/
OQo
^N
^