HomeMy WebLinkAbout2787 JAMES DR; ; CB154544; PermitCity of Carlsbad
1635 Faraday Av Carlsbad, CA 92008
10-03-2016 Residential Permit Permit No: CB154544
Building Inspection Request Line (760) 602-2725
Job Address: 2787 JAMES DR CBAD
Permit Type:
Parcel No:
Valuation:
Occupancy Group:
# Dwelling Units:
Bedrooms:
RESDNTL
1561425800
$453,945.00
1
4
Sub Type: SFD
Lot#: 2
Constuction Type: 5B
Reference#: MS130002
Structure Type: SFD
Bathrooms: 4.5
Status: ISSUED
Applied: 12/22/2015
Entered By: JMA
Plan Approved: 10/03/2016
Issued: 10/03/2016
Inspect Area:
Project Title:
Orig PC #: PC 150070
PACIFIC LEGACY:,2, 927 SF LIV
Plan Check #:
563 SF GARAGE,313 SF PATIO(S) / 313 SF DECKS
Applicant:
ALVIN WASHINGTON
STE 400
16870 W BERNARDO DR
SAN DIEGO CA 92127-1678
760-809-8732
Building Permit
Add'I Building Permit Fee
Plan Check
Add'I Plan Check Fee
Plan Check Discount
Strong Motion Fee
Park in Lieu Fee
Park Fee
LFM Fee
Bridge Fee
Other Bridge Fee
BTD #2 Fee
BTD #3 Fee
Renewal Fee
Add'I Renewal Fee
Other Building Fee
HMP Fee
Pot. Water Con. Fee
Meter Size
Add'I Pot. Water Con. Fee
Reel. Water Con. Fee
Green Bldg Stands (SB1473) Fee
Green Bldg Stands Plan Chk Fee
$1,882.76
$0.00
$1,317.93
$0.00
$0.00
$59.01
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$3,934.00
FS1
$0.00
$0.00
$19.00
$0.00
Total Fees : $32,766.79 Total Payments to Date:
Inspector:
Owner:
PACIFIC LEGACY HOMES, INC
STE 400
16870 W BERNARDO DR
SAN DIEGO CA 92127-1678
858-756-1191
Meter Size
Add'I Reel. Water Con. Fee
Meter Fee
SDCWA Fee
CFO Payoff Fee
PFF (3105540)
PFF (4305540)
License Tax (3104193)
License Tax (4304193)
Traffic Impact Fee (3105541)
Traffic Impact Fee (4305541)
Sidewalk Fee
PLUMBING TOTAL
ELECTRICAL TOTAL
MECHANICAL TOTAL
Housing Impact Fee
Housing lnlieu Fee
Housing Credit Fee
Master Drainage Fee
Sewer Fee
Additional Fees
Fire Sprinkler Fees
Fire Expedited PC Fees
TOTAL PERMIT FEES
$32,766.79 Balance Due:
Clearance:
FS1
$0.00
$356.00
$4,800.00
$0.00
$8,261 .80
$7,626.28
$0.00
$0.00
$3,160.00
$0.00
$0.00
$106.00
$89.00
$1 11.01
$0.00
$0.00
$0.00
$0.00
$881 .00
$163,00
$0.00
$0.00
$32,766.79
$0.00
NOTICE: Please take l\011CE that approval r:/ your prtject irdudes the "lrrpa;ition" a fees, dedications, reservations, or otrer exactions hereafter rolectively
referred to as 'foes/exactions." You rave 00 days fran the date this [.X'll'Trit W£ issued to prctest irrµ,sitia, r:/ these fees/exactions. If you prdest them, you rrust
fdlONthe prdest p-oceclJres set forth in C?cNernrrent Cede Section 60020(a), and file the r:,rotest and any ctrer requred infooration wth the Qty~ for
p-oo:lSSing in acrordm:e wth Caistoo M.nidpal Cede Sectim 3.32.030. Failure to tirrely fdlON that p-cx:edure wll oor any sul:x5eqJent legal oction to attad<,
review, set aside, vcid, or ainul their irrpa;ition.
You ere rerecy FURTI-ER l\011FIED that %JI' right to rrotest the SfX')dfied fees/exactions DJES NOT APFl Y to water and seM;r <XXY'€dion fees and ~ty
changes, nor plaining, zorvng, gacing or otrer sinilar appicatia, p-oo:lSSing or servire fees in cmnectim wth ths prtject. !'\CB DJES IT APFl Y to any
fees'exa:::tions a Wlich · si ·1ar to this or as to · the statute r:/ linitations has ·ous1 otrerwse e ·
Print Date: 08/09/2018
Job Address:
Permit Type:
Parcel No:
Valuation:
Occupancy Group:
# Dwelling Units:
Bedrooms:
Project Title:
1600 Buena Vista Wy
LOE-Migrated
1561424000
$ 0.00
KING PROPERTY
Permit
Work Class: LD E-M igrated
Lot#:
Reference #: DEV13013
Construction Type
Bathrooms:
Orig. Plan Check#:
Plan Check#:
Description: SWP PP -KING PROPERTY-BUENA VISTA CLNY
Applicant:
BOB SUKUP
4322 Sea Bright Pl
Carlsbad, CA 92008-3650
760-720-0098
FEE
Total Fees:
Owner:
PACIFIC LEGACY HOMES INC
16870 W Bernardo Dr, Ste 400
SAN DIEGO, CA 92127
858-756-1191
Total Payments To Date :
Land Development Engineering Division
(city of
Carlsbad
Permit No: SW160234
Status:
Applied:
Issued:
Permit
Fina led:
Inspector:
Final
Inspection:
Closed -Finaled
05/17/2016
10/03/2016
08/09/2018
AMOUNT
Balance Due:
1635 Faraday Avenue, Ca rlsbad CA 92008-7314 I 760-602-2700 I 760-602-8560 f I www.carlsbadca.gov
: ~. I ' '
. PERMIT INSPECTION HISTORY REPORT (CB154544)
Perrrnt Type:
Work Clctss.
Status:
Scheduled
Date
BLDG-Residential Application Date: 12/22/2015
Single Family Detached Issue Date: 10/03/2016
Closed -Finaled Expiration Date: 02/26/2018
IVR Number: 711392
Actual
Start Date Inspection Type Inspection No. Inspection Status
Checklist Item
BLDG-Building Deficiency
BLDG-Building Deficiency
BLDG-Plumbing Final
BLDG-Mechanical Final
BLDG-Structural Final
BLDG-Electrical Final
BLDG-Electrical Final
BLDG-Mechanical Final
BLDG-Building Deficiency
COMMENTS
Need CMI sign off
Need CMI sign off
September 29, 2017
Owner:
Subdivision:
Address:
Primary Inspector
INACTIVE PACIFIC LEGACY
HOMES
2787 James Dr
Carlsbad, CA
Reinspection
Passed
Yes
No
Yes
Yes
Yes
Yes
No
No
No
Complete
Page 5 of 5
Permit Typo BLDG-Residential Application Dato· 12/22/2015 Owner: INACTIVE PACIFIC LEGACY
HOMES
Work Class: Single Family Detached Issue Dato: 10/03/2016 Subdivision:
Status: Closed -Finaled Expiration Date· 02/26/2018 Address· 2787 James Dr
Carlsbad, CA
IVR Number: 711392
Scheduled Actual
Date Start Date Inspection Type Inspection No. Inspection Status Primary Inspector Re inspection Complete
------
Checklist Item COMMENTS Passod
BLDG-Building Deficiency No
BLDG-Plumbing Final No
BLDG-Mechanical Final No
BLDG-Structural Final No
BLDG-Electrical Final No
09/18/2017 09/18/2017 BLDG-Final 034909-2017 Failed Michael Collins Reinspection Complete
Inspection
Checklist Item COMMENTS Passed
BLDG-Building Deficiency No
BLDG-Mechanical Final Need CMI sign off No
BLDG-Electrical Final No
09/26/2017 09/26/2017 BLDG-Final 035844-2017 Failed Michael Collins Reinspection Complete
Inspection
Checklist Item COM~ NTS Passed
BLDG-Building Deficiency Need CMI sign off No
BLDG-Building Deficiency No
BLDG-Mechanical Final Need CMI sign off No
BLDG-Electrical Final No
09/27/2017 09/27/2017 BLDG-Final 036002-2017 Cancelled Michael Collins Reinspection Complete
Inspection
Checklist Item COMMENTS Passed
BLDG-Building Defiaency Need CMI sign off No
BLDG-Mechanical Final Need CMI sign off No
BLDG-Electrical Final No
BLDG-Building Deficiency No
09/28/2017 09/28/2017 BLDG-Final 036187-2017 Failed Michael Collins Reinspection Complete
Inspection
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Need CMI sign off No
BLDG-Mechanical Final Need CMI sign off No
BLDG-Electncal Final No
BLDG-Building Deficiency No
09/2912017 09/29/2017 BLDG-Final 036341-2017 Passed Michael Collins Complete
Inspection
September 29, 2017 Page 4 of 5
PERMIT INSPECTION HISTORY REPORT (CB154544)
Porm,t Type: BLDG-Residential Application Date: 12/22/2015 Owner: INACTIVE PACIFIC LEGACY
HOMES
Work Class. Single Family Detached Issue Date: 10/03/2016 Subdivision:
Status; Closed -Finaled Expiration Date: 02/26/2018 Address: 2787 James Dr
Carlsbad, CA
IVR Number: 711 392
Scheduled Actual
Date Start Date Inspection Type Inspection No. Inspection Status Primary Inspector Reinspection Complete
08/0312017 08/03/2017 BLDG-23 030560-2017 Passed Michael Collins Complete
Gas/TesURepairs
Checklist Item COMMENTS Passed
BLDG-Building Deficiency No
08114/2017 08/14/2017 BLDG-Electric Meter 031619-2017 Passed Michael Collins Complete
Release
Checklist Item COMMENTS Passed
BLDG-Building Deficiency EMR emailed to SDGE. Yes
08125/2017 08/2512017 BLDG-Final 032833-2017 Cancelled Andy Krogh Reinspection Complete
Inspection
Checkltst Item COMMENTS Passed
BLDG-Building Deficiency No
BLDG-Plumbing Final No
BLDG-Mechanical Final No
BLDG-Structural Final No
BLDG-Electrical Final No
08130/2017 08/30/2017 BLDG-24 033261-2017 Partial Pass Michael Collins Reinspectlon Incomplete
Rough/Topout
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Partial final pre lim, gas release emailed to No
SDGE.
BLDG-44 033262-2017 Partial Pass Michael Collins Reinspection Incomplete
Rough/Ducts/Dampe
rs
Checklist Item COMMENTS Passed
BLDG-Building Deficiency . Pre lim final, gas release emailed to SDGE. Yes
09/06/2017 09/06/2017 BLDG-Final 033781-2017 Failed Michael Collins Reinspection Complete
Inspection
Checklist Item COMMENTS Passed
BLDG-Building Deficiency No
BLDG-Plumbing Final No
BLDG-Mechanical Final No
BLDG-Structural Final No
BLDG-Electrical Final No
09/07/2017 09/07/2017 BLDG-Final 033974-2017 Failed Michael Collins Reinspection Complete
Inspection
September 29, 2017 Page 3 of 5
' PERMIT INSPECTION HISTORY REPORT (CB154544)
Permit Type: BLDG-Residential Application Date 12/22/2015 Owner: INACTIVE PACIFIC LEGACY
HOMES
Work Class: Single Family Detached Issue Date· 10/03/2016 Subdivision:
Status: Closed -Finaled Expiration Date: 02/26/2018 Address: 2787 James Dr
Carlsbad, CA
IVR Number: 711392 -
Scheduled Actual
Date Start Date Inspection Type Inspection No. Inspection Status Primary Inspector Reinspection Complete
Checklist Item COMMENTS Passed
BLDG-Building Deficiency No
BLDG-14 No
Frame-Steel-Bolting-Welding
(Decks)
BLDG-24 Rough-Topout No
BLDG-34 Rough Electrical No
BLDG-44 No
Rough-Ducts-Dampers
05/19/2017 05/17/2017 BLDG-84 Rough 023590-2017 Cancelled Paul York Reinspection Complete
Combo(14,24,34,44)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency No
BLDG-14 No
Frame-Steel-Bolting-Welding
(Decks)
BLDG-24 Rough-Topout No
BLDG-34 Rough Electrical No
BLDG-44 No
Rough-Ducts-Dampers
05/25/2017 05/25/2017 BLDG-84 Rough 024466-2017 Passed Michael Collins Complete
Combo(14,24,34,44)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Minor pick up. Yes
BLDG-14 Yes
Frame-Steel-Bolting-Welding
(Decks)
BLDG-24 Rough-Topout Yes
BLDG-34 Rough Electrical Yes
BLDG-44 Yes
Rough-Ducts-Dampers
05/31/2017 05/31/2017 BLDG-16 Insulation 024903-2017 Passed Michael Collins Complete
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
06/09/2017 06/09/2017 BLDG-17 Interior 025834-2017 Passed Michael Collins Complete
Lath/Drywall
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Shower/tub lath only Yes
06/13/2017 06/13/2017 BLDG-18 Exterior 026026-2017 Passed Michael Collins Complete
Lath/Drywall
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-Building Deficiency Exterior shear, see card No
September 29, 2017 Page 2 of 5
' '
PERMIT INSPECTION HISTORY REPORT (CB154544)
Permit Typo: BLDG-Residential Application Date: 12/22/2015 Owner: INACTIVE PACIFIC LEGACY
HOMES
Work Class. Single Family Detached Issue Date: 10/03/2016 Subdiv1s1on"
Status. Closed -Finaled Expiration Date: 02/26/2018 Address: 2787 James Dr
Carlsbad, CA
IVR Number: 711392
Scheduled Actual
Date Start Date Inspection Type Inspection No, Inspection Status Primary Inspector Reinspection Complete
12/14/2016 12/14/2016 BLDG-14 005650-2016 Partial Pass Michael Collins Reinspectlon Incomplete
Frame/Steel/Bolting/
Welding (Decks)
NOTES Created By TEXT Created Date
Michael Collins Pre lim. 12/14/2016
03/01/2017 03/01/2017 BLDG-13 Shear 015054-2017 Partial Pass Paul Burnette Reinspeclion Incomplete
Panels/HD (ok to
wrap)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency No
03/09/2017 03/09/2017 BLDG-14 016096-2017 Passed Michael Collins Complete
Frame/Steel/Bolting/
Welding (Decks)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Prehm deck sheathing. Yes
NOTES Created By TEXT Created Date
Michael Collins Pre ltm 12/14/2016
03/22/2017 03122/2017 BLDG-13 Shear 017230-2017 Passed Michael Collins Complete
Panels/HD (ok to
wrap)
Checklist Item COMMENTS Passed
BLDG-Bu1ld1ng Deficiency Waste to POC, Bldg supply, meter to bldg Yes
03/2812017 03/28/2017 BLDG-15 017948-2017 Passed Michael Collins Complete
Roof/ReRoof (Patio)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
04/1812017 04/18/2017 BLDG-18 Exterior 020343-2017 Failed Michael Collins Reinspection Complete
Lath/Drywall
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Exterior shear. see card No
0510112017 05101/2017 BLDG-13 Shear 021698-2017 Passed Michael Collins Complete
Panels/HO (ok to
wrap)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
05/12/201 7 05/12/2017 BLDG-84 Rough 023264-2017 Failed Michael Collins Relnspection Complete
Combo( 14,24,34,44)
September 29, 2017 Page 1 of 5
Inspection History:
10/31/2016: 11-BLDG-Ftg/Foundation/Piers Approval Completed By MC;
10/31/2016: 31-BLDG-Underground/Conduit-Wiring Approval Completed By MC UFER
• .
. ,i~~\
~ CITY o,
CB154544 2787 JAMES DR
CARLSBAD
Building Division INSPECTION RECORD PACIFIC LEGACY:,2, 927 SF LIV
563 SF GARAGE,313 SF PATIO(S) / 313 SF DECKS
RESDNTL SFD
0 INSPECTION RECORD CARD WITH APPROVED Lot# 2 ALVIN WASHI NGTON
PLANS MUST BE KEPT ON THE JOB
0 CALL BEFORE 3:30 pm FOR NEXT WORK DAY INSPECTION
0 FOR BUILDING INSPECTION CALL: 760-602-2725
OR GO TO: www.Carlsbadca.gov/Buifding AND CLICK ON
~Request Inspection"
DATE:
Required Prior to Requesting Building Final If Checked YES
Planning/Landscape 760-944-8463 Allow 48 hours
CM&I (Engineering lnspectfons) 76()-438-3891 Call before 2 pm
Fire Prevention 760-602-4660 Allow 48 hours
Inspector
#31
REINFORCED STEEL #34
#66 MASONRY PRE GROUT #33
□GROUT □ WALL DRAINS #35
#10 TILT PANELS
#11 POUR STRIPS
#11 COLUMN FOOTINGS
#14 SUBFRAME O FLOOR O CEILING
#15 ROOF SHEATHING #43
#13 EXT. SHEAR PAN ELS #49
#16 INSULATION
#18 EXTERIOR LATH #81
#17 INTERIOR LATH & DRYWALL #82
#51 POOL EXCA/STEEL/BOND/FENCE #83 ROOF SH EATING, EXT SHEAR (13,15)
#55 PREP LASTER/FINAL #84 FRAME ROUGH COMBO (14,24,34,44)
T-Bar (14,24,34,44) '
FINAL OCCUPANCY (19,29,39,49)
TOP OUT □ WASTE D WTR A/S UNDERGROUND VISUAL
#27 TUB & SHOWER PAN A/S UNDERGROUND HYDRO
#23 S TEST O GAS PIPING A/S UNDERGROUND FLUSH
#25 WATER HEATER A/S OVERHEAD VISUAL
#28 SOLAR WATER A/S OVERHEAD HYDROSTATIC
A/SFINAL
F/A ROUGH-IN
F/AFINAL
FOLLOW UP INSPECTION AXED EXTINGUISHING SYSTEM ROUGH-IN
#605 NOTICE TO CLEAN FIXED EXTING SYSTEM HYDROSTATIC TEST
#607 WRITTEN WARNING AXED EXTINGUISHING SYSTEM ANAL
#609 NOTICE OF VIOLATION MEDICAL GAS PRESSURE TEST
#610 VERBAL WARNING MEDICAL GAS FINAL
REV10/2012 SEE BACK FOR SPECIAL NOTES
, ;.
Section 5416. Health and Safety Code, State of California
(a) There shall be not less than pne water closet for each 20 employees or fractional part thereof working at a
construction job site. The water closet shall consist of a patented chemical type toilet.
(b) For the purpose of this section the term construction site shall mean the location on which actual construction of a
building is in progress.
(c) A violation of this section shall constitute a misdemeanor.
All construction or work for which a permit is required shall be subject to inspection and all such construction or work
shall remain accessible and exposed for inspection purposes until approved by the inspector. Work shall not be done
beyond the point indicated in each successive inspection without first obtaining the approval of the inspector.
t
GeoTek, Inc.
CLIENT:
PROJECT:
WORK IN PROGRESS ( ) GRADING
( ) STREET: SG __ B __ AC __
( ) SIDEWALK: SG __ B __
EQUIPMENT:
TEST RESULTS
TEST LOCATION NO.
\_
" ""' "--~
"' "
.. -
sY: /,. M f1 e t-r A-1... :::..r-.
PRINT NAME
COPIES TO: OFFICE CLIENT/REP
FOREMAN:
Lb1111 t Ju
Field Observation Report
WO:.,'$ ../qJ t"' I-..
DATE: ~ / l-f / / l
DAY: Mk,w TH F s s
HOURS: 7 ,J
) UTILITY B/F: S __ W __ JT __ SD__ OTHER __ _
( ) CURB & GUTTER: SG __ B
) WALL '54, FOUNDATION OTHER ________ _
ELEV/ MOISTURE DRY SOIL TEST
DEPTH CONTENT DENSITY TYPE MAX D TYPE REL COMP
' "" " " /l
" /f/ 1/ ,
'°1 I'' I
AGENCY CONTRACTOR FIELD FILE
(WHITE)___ (YELLOW) __ _ (PINK) __ _ (GOLDENROD) __ _ (GREEN) __ _
ATTACH ADDITIONAL SHEETS AS NEEDED. THIS IS SHEET OF
(
(._ City of
Carlsbad
CIRCUIT CARD
B-36
Developtr nt f:._ 1.,1 , ~
Building Division
1635 Faraday Avenue
760-602-2719
www.carlsbadca.gov
TIIIS CARD '-fl;ST BE FILLED Ollf ANO AVAILABLE AT THE SERVICE EO UlPMENT FOR THE ROt.;GJI INSPECTION
Address: '2'1 S-1 4A•{t°~ D(2, Pennit Number: a L~i1. ~.LL,,1
Owner: I Phone:
Contractor.e,< /I t "'c-(' Cl,:-C ;-/' ·c I Phone:Gf'5'-.\ 7 7-25?C.'?
Area in Sq. Ft. '3 (2J-
PA:-;''.L. •i..oC/ U2 cc,c) A.IC. n, 'J-1..r n VOLTS I 0 i WIRE
LOCATION CKT BKR WIRE MISC REC REC LTG MISC WIRE BKR CKT LOCATION
SIZE SIZE TYPE SIZE TYPE SIZE ~.-, 1 J.n l'L C-'-I I t 1-C 2o 2 !t.#Ud,,£,V /
t sf c.,.,,c/ 3 •1,.-., 1 7 r 3 I t L c.. -lo 4 ~ vr,...lrv-2-
/F,5 5 'J .r, '?_ ('_ { 1 I <-1 C ( (-6 5t "k.>1,/ e V
{) I t/!. /i J 4fi. lfr 7 ,.., /? (' I I;, '7 /y C. ( ,;-8 pc/ k!_1,, 1, I I-¼
e,....;n 9 ? /\ I I C-I (., L I '1 C n-10 /~f.{Lpt 'L
nt'n,•;, f 11 ') /. ,1 / '-I 2.. q /y c.: /, 12 MS 6,,f l, .,,. -J! .. -13 ?,n rz_ (_ l/ .x s-I 'l c:.. /J 14 f,1 ~ /x:('!l,,r,
i:::x (..!/:=T 15 ,,, , 1 I L (" 6 5 fS /'{ C (J 16 iJ(ui.1 it?.~
IJI
Jlr liY'"/' 17 0 ID C I 7 7 iL{ C /j 18 ()o{ (L,,-,i ('.,,. "'
(_" I 19 0 l e) C ) if I / / \-( C IS-20 c._f Pc•ce
81'~ ? 1:'1/ 1~ I 21 ?/_ '-C I > " /'-( c.. /J 22 J
{ I ( -l 23 / .)17 (,, c.. ' I '-I i.'/ C /J 24 JG•r._'4• tQ,
( 11'\ I ,,., t1 25 11. /1J ~ I ') c; IV C: ii\ 26 /'. -'il ~-a.I lvt
( II ['--<-I )U (0 c.. ' ·3 / r-28 ,.. 12 v 27 /Y C Lryc-... r ""'1 -r.
( lr-✓Jr 29 ·21 ~ c."' , 30
{ r l,,,, ... c:.,r 31 [71/U ~ C I 32
~ lbJ C;:,J 33 ,7 I d-. C I 34
35 !JU 6 r. I 36 r J11 e /1
°h:l V 37 I< ;y C I 38
&,t1,, I l 39 Z.o (l, l.. ·, 40
,vis !J .1r ii. 41 i , J (L (' 1 42
MAIN: 0 'k.rj; C/ AMP BRK/FUSE O MLO Computed Load L v-:-Ct L AMPS
I See Calculation Worl<sheet on back BUS: •'L2 5 AMP Branch circuits required: Service entrance or feeder conductors: ~
A) Size: No. lf 8) Type: CU O AL
A) Lighting Circuits 220-3(b), 4(d)
B) Two Small Appliance Circuits 210-11(e)
C) Insulation: D) Conduit Size: __ C) Laundry Circuit 220-16(b)
Service ground/bond:
B) Type: E1'cu □ AL
D) Central Heating Equipment 422-12
A) Size: No. '/ E) Bathroom 210-52(d)
C) Clamp location(s):
:2ruFER 250 -50(c) Remarks:
~aterPipe 250 -104
2t:und Rod 250-52
"t,O)
GFCI locaUons 210 -8, 680 -70:
~lchen
I certify that all terminations have been torqued in accordance with manufacturers
~throom(s) instructions and that the worl shown on this circuit card represents the full 9Xtent of
Garage(s) □Hydromassage Tub the work performed ~ar t~rrrt
GK5utdoors 0 0 Owner I · Ci• ·'C e (...-C(.E
AF~tected Gire. 21 O -12 □Contractor t:::Y)[~'2.5 .. e:'/dt ✓• ·c
Bedroom(s} 0 Signed b / /7/ Date ~ =--r;, tl I V /Ln/1 ..,,, · , ·7
l ~
B-36 Page 1 of 2 Rev. 03/09
1.
SINGLE FAMILY DWELLING
ELECTRICAL SERVICE LOAD CALCULATION
As an alternative method, the STANDARD METHOD
found in ARTICLE 220 of the National Electric Code, may be used
GENERA!, LIGHTING LOADS
Dwelling.) ,f-,2 1/ sq. ft. x 3 VA= 220-3(a) /_0,J} L VA
Small appliance loads -220-16(a) 1500 VA x Z: circuits= Jo c? o VA
Laundry load -220-16(b) 1500 VA x -.:..:::... ____ circuits = j c> c, CJ VA / 1 General Lighting Total b)7 L VA
2. COOKING EQUIPMENT LOADS -Nameplate Value
Range ______ VA=
Cooktop Cr 45 VA=
Oven (s) fi1:po VA=
____ VA
-=-___ VA
Ji:ooo VA
Cooking Equipment Total
3. ELECTRIC DRYER 220-18 (Nameplate, 5000 VA minimum)
Dryer Total 5:<J d (3 Dryer J<A'.?0 VA=
4. FIXED APPLIANCE LOADS 230-30 (b) (3)
Dishwasher =
Disposal=
Compactor=
Water Heater =
Hydromassage Bathtub =
Microwave Oven =
/J?O VA
/7 oo VA
~---VA Yoo VA
____ VA
/D2c VA
/?c.JU VA
VA
-Boilt•in vacoum -Jd=-f c~r C.h.qr§e =
5. OPTIONAL SUBTOTAL (Add all of the above totals)
?o oc:> VA
Fixed Appliance Total I 2-r-0 0 VA
____ VA
6. APPLYING DEMAND FACTORS -TABLE 220-30
First 10,000 VA x 100% = 10,000VA
Optional Subtotal (from line 5) { Remaining 3 Z 'S 7'2... VA x 40%= I 1-l..t<t, t VA
J I
7. HEATING OR AC LOAD -TABLE 220-30 t'i_ tcoo Larger of the Heating or AC Load = VA I
8. OPTIONAL LOADS TOTAL (Add totals from lines 6 and 7) = . 51. 2__</_J,. <y VA
I
9. MINIMUM SERVICE SIZE = Optional Loads Total = (_s-S; C::> 1...Ampere
240 Volt
(Please put total on front of card under Computed Load)
October 24, 2016
Building Inspector
City of Carlsbad
Building Inspection
1635 Faraday Avenue
Carlsbad, CA 92008
~
PACIFIC LEGACY
HO M ES
RE: Buena Vista Colony -2787 James Drive, Building Permit
Dear Building Inspection,
The construction survey staking was completed by Torgersen Surveying, Inc. on October 3, 2016. The
construction survey staking included the building corners. I have reviewed the staking information and
foundation formwork layout. The building is located per the site plan and the survey stakes set by
Torgersen Surveying, Inc.
Please let us know if you have any questions or need anything else. Thank you in advance.
Sincerely,
PACIFIC LEGACY HOMES, INC.
/4/LP~
Michael Graham, PE
President
16870 W. BERNARDO DRIVE, SU ITE 400 SAN DIEGO, CALIFORNIA 92127T 858.756.1191