HomeMy WebLinkAbout2788 James Dr; ; CBR2018-1303; PermitPrint Date: 01/28/2020
Job Address:
Permit Type:
Parcel No:
Valuation:
Occupancy Group:
# Dwelling Units:
Bedrooms:
Project Title:
2788 James Dr
BLDG-Residential
1561424900
$22,374.00
Residential Permit
Work Class: Addition
Lot#:
Reference #:
Construction Type:
Bathrooms:
Orig. Plan Check#:
Plan Check #:
Description: RAMIREZ: 132 SF ADDITION (BAR & BATH)
Applicant:
SAMUEL WRIGHT
2911 State St, A
CARLSBAD, CA 92008-2338
760-213-1460
BUILDING PERMIT FEE ($2000+)
BUILDING PLAN CHECK FEE (BLDG)
Owner:
TRUST RAMIREZ FAMILY TRUST
2788 James Dr
CARLSBAD, CA 92008
ELECTRICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL
GREEN BUILDING STANDARDS PLAN CHECK & INSPECTION
MECHANICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL
PLUMBING BLDG RESIDENTIAL NEW/ADDITION/REMODEL
SB1473 GREEN BUILDING STATE STANDARDS FEE
STRONG MOTION-RESIDENTIAL
SWPPP INSPECTION FEE TIER 1-Medium BLDG
SWPPP PLAN REVIEW FEE TIER 1-MEDIUM
Total Fees: $988.37 Total Payments To Date: $988.37
("atyof
Carlsbad
Permit No: CBR2018-1303
Status:
Applied:
Issued:
Permit
Finaled:
Closed -Finaled
06/01/2018
07/03/2018
Inspector: TFraz
Final
Inspection: 1/28/2020 3:10:56PM
Balance Due: $0.00
$230.27
$161.19
$41.00
$170.00
$39.00
$49.00
$1.00
$2.91
$238.00
$56.00
Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter
collectively referred to as "fees/exaction." You have 90 days from the date this permit was issued to protest imposition of these
fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the
protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section
3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their
imposition.
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection
fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this
project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the
statute of limitation has previously otherwise expired.
1635 Faraday Avenue, Carlsbad, CA 92008-7314 I 760-602-2700 \ 760-602-8560 f I www.carlsbadca.gov
,..
('Cityof
Carlsbad
JOB ADDRESS
'2.
CT/PROJECT#
Building Permit Application
1635 Faraday Ave., carlsbad, CA 92008
Ph: 780-80247:1.9 Fax: 760-602-8558
email: buildlng@carlsbadca.gov
www.carlsbadca.gov
Est. Value
Plan Ck. Deposit
Date
SUITE#/SPACE#/UNIT#
PHASE # # OF UNITS # BEDROOMS # BATHROOMS TENANT BUSINESS NMIE
DESCRIPTION OF WORK: Include Square Feet Of Affected Area(s)
1.L-
p. .._. C \(p\. \_1
EXISTING USE GARAGE (SF) PATIOS (SF)
ADDRESS
~ -C \l ,-, 'T•t'C..-"-~ •
PHONE
EMAIL
CONTRACTOR eus. NAME
ADDRESS ADDRESS
CITY STATE CITY STATE
PHONE FAX PHONE FAX
EMAIL EMAIL
STATE UC.# STATE UC.# CLASS
CONSTR. lYPE OCC. GROUP
CllYBUS. UC.#
FIRE SPRINKLER~
YES □ No,tl
(Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the l)rovisions of the Contractor's license Law !Chapter 9, oommending with Section 7000 of Division 3 of the Business and Professions Code) or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars {$500)).
WORKERS' COMPENSATION
Workers' Compensation Declaration: I hereby alfrrm under penally of petjufy one of the fallowing declarations:
D I have and will maintain a certificate of consent lo self-insure for wol1ws' compensation as provided by Section 3700 of Ille Labor Code, for the performance of the work for which lhis permit is issued.
D I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for lhe perlom1ance of lhe work for which this permtt is issued. My workers' compensation insuraoc:e carrier and poicy
number are: Insurance Co. _____________________ Poley No. ______________ Expiration Date _________ _
This seclion need not be completed if the pem1it is for one hundred dollars ($100) or less. D Certificate of Exemp1ion: I certify that in the performance of the work for which lhis permit is issued, I shall not employ any person in any manner so as to become subject to lhe Workers· Compensation Laws of
California. WARNING; Failure to secure workers' compensation coverage is unlawful, and shall subjectan employer to criminal penalties and civil fines up 10 one hundred thousand dollars (&100,000), in
addition to lhe cost of compensation, damages as provided for in Section 3706 Ol lhe Labor code, interesl and attorney's fees.
,85 CONTRACTOR SIGNATURE □AGENT DATE
OWNER-BUILDER DECLARATION
I here~ affirm that I am exempt from Contractor's License Law f(){ lhe following reason:
D I, as owner of the property or my employees wtth wages as their sole compensation, will do the work cmd the structure is not inlended or offered for sale (Sec. 7044, Business and Professions Code; The Contractor's
License Law does not apply to an owner of property who builds or improves thereon, and who does such work himsett or lhrough his own employees, provided that such i~rovements are not i ntencled or offered !or
sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving Iha! he did no! buikl or improve for the purpose of sale).
D I, as owner of the property, am exclusively contracting with icensed contractors lo CO!IStrucl the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does no! apply to an owner of
property who builds or improves thereon, and contracts for such projects with contracior(s) licensed pursuant to the Contractor's License Law).
□ I am exempt under Section _______ Business and Professions Code for this reason:
1. I personally plan lo provide lhe major labor and materia1s for construction of the proposed property improvement □ Yes □ No
2. I (have I have not) signed an application for a buildirg permtt for lhe proposed work.
3. I have contracted with the following person (flm1) to provide the proposed construc~oo (include name address I phone I contractors' license number):
4. I plan to provide portions of the work, but I have hi e following person to coordinate, supervise and provide the major work (include name I ada-ess I phone I contractors' license number):
(hired) the folio · ns to proVide lhe work indicated {include name I ad<nss I phone I type of work):
./1:5 PROPERTY OWNER SIGNATURE DATE
Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk managemenl and prevention program under Sections 25505, 25533 or 25534 of the
Presley-Tanner Hazardous Substance Account Act? □ Yes □ No
Is the applicant or future building occupant required to obtain a permit from the air JX)llution control district or air Quality management district? □ Yes □ No
Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? □ Yes D No
IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF
EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT.
1 certify that I have re11d the application and state that the above Information ls correct and that the infonnation on the plans Is accurate. I agree to comply v.ith all City ordinances and State lav,s relating lo building construction.
I hereby aulhorize represenlative of the City of Cansbad to enter upon the aoove mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY ANO KEEP HARMLESS THE CITY OF CARLSBAD
AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ~y WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT.
OSHA M OSHA pennit is required for excavations over 5'0' deep and demolition or construction of structures over 3 stories in height.
EXPIRATION: Every pennit issued by the Building Official under the provisions o is Code shall expire by limitation and become null and void 11 the 001lding or mrk aulhorized by sud1 pc,nnit is no\ commenced v.ithin
180 days from the date of such pennit or if the building or authorized by pe · suspended or abandoned at anytime after the mrk is commenced for a penod of 180days (Seeton 1C6.4.4 Uniform El.Jilding Code).
_.l!5 APPLICANT'S SIGNATURE DATE ' • , /
PERMIT INSPECTION HISTORY REPORT (CBR2018-1303)
Permit Type: BLDG-Residential Application Date: 06/01/2018 Owner:
Work Class: Addition Issue Date: 07/03/2018 Subdivision:
Status: Closed -Finaled Expiration Date: 04/07/2020 Address:
IVR Number: 11701
Scheduled Actual Date Start Date Inspection Type Inspection No. Inspection Status Primary Inspector
01/28/2020 01/28/2020 BLDG-Final
Inspection
January 28, 2020
117594-2020
Checklist Item
BLDG-Plumbing Final
BLDG-Mechanical Final
BLDG-Structural Final
BLDG-Electrical Final
Passed Tony Alvarado
COMMENTS
TRUST RAMIREZ FAMILY TRUST
CARLSBAD TCT#98-16
2788 James Dr
Carlsbad, CA 92008-1953
Reinspection Complete
Passed
Yes
Yes
Yes
Yes
Complete
Page 3 of3
PERMIT INSPECTION HISTORY REPORT (CBR2018-1303)
Permit Type: BLDG-Residential Application Date: 06/01/2018 Owner:
Work Class: Addition Issue Date: 07/03/2018 Subdivision:
Status: Closed -Finaled Expiration Date: 04/07/2020 Address:
IVR Number: 11701
Scheduled Actual Date Start Date Inspection Type Inspection No. Inspection Status Primary Inspector
07/3012019 07/30/2019 BLDG-27 Shower 099025-2019
Pan/Tubs
Checklist Item
BLDG-Building Deficiency
BLDG-83 Roof
Sheating, Exterior
Shear (13, 15)
099026-2019
Passed
COMMENTS
Passed
Checklist Item COMMENTS
BLDG-Building Deficiency Not ready
BLDG-13 Shear Panels-HD (ok
to wrap)
BLDG-13 Shear Panels-HD (ok
to wrap)
Michael Collins
Michael Collins
BLDG-15 Roof See card for minor pick up
Sheathing-Reroof
BLDG-15 Roof
Sheathing-Reroof
BLDG-84 Rough 099024-2019 Failed Michael Collins
Combo( 14,24,34,44)
Checklist Item COMMENTS
BLDG-Building Deficiency Not ready.
BLDG-Building Deficiency Not ready
BLDG-14 Prelim wall only at Line 2. Ok to re-install
Frame-Steel-Bolting-Welding shear.
(Decks)
09/09/2019 09/09/2019 BLDG-16 Insulation 103428-2019
Checklist Item
BLDG-Building Deficiency
BLDG-18 Exterior 103429-2019
Lath/Drywall
Checklist Item
BLDG-Building Deficiency
BLDG-84 Rough 103427-2019
Combo(14,24,34,44)
Checklist Item
BLDG-Building Deficiency
BLDG-Building Deficiency
10/10/2019 10/10/2019 BLDG-17 Interior
Lath/Drywall
107153-2019
January 28, 2020
Passed
COMMENTS
Passed
COMMENTS
Passed
COMMENTS
Passed
Chris Renfro
Chris Renfro
Chris Renfro
Tony Alvarado
TRUST RAMIREZ FAMILY TRUST
CARLSBAD TCT#98-16
2788 James Dr
Carlsbad, CA 92008-1953
Reinspection Complete
Passed
Yes
Passed
No
No
Yes
Yes
No
Reinspection
Passed
No
No
Yes
Passed
Yes
Passed
Yes
Passed
Yes
Yes
Complete
Complete
Complete
Complete
Complete
Complete
Complete
Page 2 of 3
PERMIT INSPECTION HISTORY REPORT (CBR2018-1303)
Permit Type: BLDG-Residential Application Date: 06/01/2018 Owner: TRUST RAMIREZ FAMILY TRUST
Work Class: Addition Issue Date: 07/03/2018 Subdivision: CARLSBAD TCT#98-16
Status: Closed -Finaled Expiration Date: 04/07/2020 Address: 2788 James Dr
IVR Number: 11701 Carlsbad, CA 92008-1953
Scheduled Actual Inspection Type Inspection No. Inspection Status Primary Inspector Reinspection Complete Date Start Date
07/24/2018 07/24/2018 BLDG-SW-Pre-Con 064736-2018 Passed Tim Frazee Complete
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
12/20/2018 12/20/2018 BLDG-21 079299-2018 Passed Tim Frazee Complete
Underground/Unde
rfloor Plumbing
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
01/08/2019 01/07/2019 BLOG-11 080584-2019 Passed Tim Frazee Complete
F oundation/Ftg/Pier
s (Rebar)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Rebar for footings and SOG OK Yes
BLDG-12 080585-2019 Passed Tim Frazee Complete
Steel/Bond Beam
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
06/21/2019 06/21/2019 BLOG-83 Roof 095317-2019 Failed Michael Collins Reinspection Complete
Sheating, Exterior
Shear(13,15)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Not ready No
BLDG-13 Shear Panels-HD (ok No
to wrap)
BLDG-15 Roof No
Sheathing-Reroof
BLDG-84 Rough 095316-2019 Failed Michael Collins Reinspection Complete
Combo(14,24,34,44)
Checklist ltem COMMENTS Passed
BLDG-Building Deficiency Not ready No
07/03/2019 07/03/2019 BLDG-84 Rough 096250-2019 Partial Pass Michael Collins Reinspection Incomplete
Combo(14,24,34,44)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Not ready No
BLDG-14 Prelim wall only at Line 2. Ok to re-install Yes
Frame-Steel-Bolting-Welding shear.
(Decks)
January 28, 2020 Page 1 of 3
DATE: June 27, 2018
JURISDICTION: Carlsbad
PLAN CHECK#.: CBR2018-1303
PROJECTADDRESS: 2788JamesDr
✓• EsG1I
A SAfEt,w1l\ Company
SET: II
PROJECT NAME: Addition for Ramirez Residence
□ APPLICANT
□ JURIS.
~ The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes.
D The plans transmitted herewith will substantially comply with the jurisdiction's
codes when minor deficiencies identified below are resolved and checked by building
department staff.
0 The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
D The check list transmitted herewith is for your information. The plans are being held at EsGil
until corrected plans are submitted for recheck.
0 The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
0 The applicant's copy of the check list has been sent to:
~ EsGil staff did not advise the applicant that the plan check has been completed.
D EsGil staff did advise the applicant that the plan check has been completed.
Person contacte1/:
Date contacted: (byrt0) )
Mail Telephone Fax ln~n
0 REMARKS:
By: Abe Doliente
EsGil
6/21/18
Telephone#:
Email:
Enclosures:
9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576
DATE: June 12, 2018
JURISDICTION: Carlsbad
PLAN CHECK#.: CBR2018-l303
PROJECT ADDRESS: 2788 James Dr
✓• EsG1I
SET:I
PROJECT NAME: Addition for Ramirez Residence
□ APPLICANT
□ JURIS.
D The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes.
D The plans transmitted herewith will substantially comply with the jurisdiction's
codes when minor deficiencies identified below are resolved and checked by building
department staff.
D The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
~ The check list transmitted herewith is for your information. The plans are being held at Es Gil
until corrected plans are submitted for recheck.
D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
~ The applicant's copy of the check list has been sent to:
Sam Wright
D EsGil staff did not advise the applicant that the plan check has been completed.
~ EsGil staff did advise the applicant that the plan check has been completed.
Person contacted: Sam Wright Telephone#: 760-213-1460
Date contacted: \e/r-Z-(b~ Email: wrighthaus@roadrunner.com ???
Mail ~.,_Telephone Fax In Person
0 REM KS:
By: Abe Doliente
EsGil
6/5/18
Enclosures:
9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax (858) 560-1576
Carlsbad CBR2018-1303
June 12, 2018
PLAN REVIEW CORRECTION LIST
SINGLE FAMILY DWELLINGS AND DUPLEXES
PLAN CHECK#.: CBR2018-1303
PROJECT ADDRESS: 2788 James Dr
FLOOR AREA: Addition -132 SF
REMARKS:
DATE PLANS RECEIVED BY
JURISDICTION:
DATE INITIAL PLAN REVIEW
COMPLETED: June 12,2018
FOREWORD (PLEASE READ):
JURISDICTION: Carlsbad
STORIES:
HEIGHT:
DATE PLANS RECEIVED BY
ESGIL CORPORATION: 6/5/18
PLAN REVIEWER: Abe Doliente
This plan review is limited to the technical requirements contained in the California version of
the International Residential Code, International Building Code, Uniform Plumbing Code,
Uniform Mechanical Code, National Electrical Code and state laws regulating energy
conservation, noise attenuation and access for the disabled. This plan review is based on
regulations enforced by the Building Department. You may have other corrections based on
laws and ordinance by the Planning Department, Engineering Department, Fire Department or
other departments. Clearance from those departments may be required prior to the issuance of
a building permit.
Present California law mandates that construction comply with the 2016 edition of the California
Code of Regulations (Title 24), which adopts the following model codes: 2015 IRC, 2015 IBC,
2015 UPC, 2015 UMC and 2014 NEC.
The above regulations apply, regardless of the code editions adopted by ordinance.
The following items listed need clarification, modification or change. All items must be satisfied
before the plans will be in conformance with the cited codes and regulations. Per Sec. 105.4 of
the 2015 International Building Code, the approval of the plans does not permit the violation of
any state, county or city law.
To speed up the recheck process, please note on this list (or a copy) where each
correction item has been addressed, i.e., plan sheet number, specification section, etc.
Be sure to enclose the marked up list when you submit the revised plans.
Carlsbad CBR2018-1303
June 12, 2018
Please make all corrections, as requested in the correction list. Submit FOUR new
complete sets of plans for commercial/industrial projects (THREE sets of plans for
residential projects). For expeditious processing, corrected sets can be submitted in one
of two ways:
1. Deliver all corrected sets of plans and calculations/reports directly to the City of
Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-
2700. The City will route the plans to EsGil and the Carlsbad Planning, Engineering and
Fire Departments.
2. Bring TWO corrected set of plans and calculations/reports to EsGil, 9320 Chesapeake
Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of
plans and calculations/reports directly to the City of Carlsbad Building Department for
routing to their Planning, Engineering and Fire Departments.
NOTE: Plans that are submitted directly to EsGil only will not be reviewed by the City
Planning, Engineering and Fire Departments until review by EsGil is complete.
PLANS
1. All sheets of plans must be signed by the person responsible for their
preparation. The structural portions signed and sealed by the California state
licensed engineer or architect responsible for their preparation, along with
structural calculations. (California Business and Professions Code). Signatures
will be verified before the plans are approved.
ROOFS/DECKS/BALCONIES
2. Show the required ventilation for attics {or enclosed rafter spaces formed where
ceilings are applied directly to the underside of roof rafters). The minimum vent
area is 1/150 of attic area (or 1/300 of attic area if at least 40% (but not more
than 50%) of the required vent is located no more than 3' below the ridge). Show
on the plans the area required and area provided. Section R806.
3. Where eave vents are installed, insulation shall not block the free flow of air. A
minimum of 1" of air space shall be provided between the insulation and the roof
sheathing. To accommodate the thickness of insulation plus the required 1"
clearance, member sizes may have to be increased for rafter-ceiling joists.
Section R806.3.
4. Note on the plans: "Attic ventilation openings shall be covered with
corrosion-resistant metal mesh with 1/16" minimum to¼" maximum openings.
Section R806.1.
FOUNDATION REQUIREMENTS
5. Include the City's soil stamp on the plans upon approval. This is not a correction
item.
Carlsbad CBR2018-1303
June 12, 2018
RESIDENTIAL GREEN BUILDING STANDARDS
In addition to the notes already shown on the plans, please note the following:
6. Note on the plans that prior to final inspection the licensed contractor, architect
or engineer in responsible charge of the overall construction must provide to the
building department official written verification that all applicable provisions
from the Green Building Standards Code have been implemented as part of the
construction. CGC 102.3.
ENERGY CONSERVATION
7. When replacing or modifying the mechanical system: If applicable
o If more than 40' of new ductwork is installed in unconditioned space, HERS
inspection is required for both existing and new duct sealing.
o Replacement of mechanical equipment (air handler, condensing unit of an air
conditioner or heat pump, cooling or heating coil, or the furnace heat
exchanger) requires HERS inspection.
o Note: The CF1 R-AL T-HVAC form may be submitted at the final inspection, it
is not required at initial plan submittal.
MISCELLANEOUS
To speed up the review process, note on this list (or a copy) where each correction item
has been addressed, i.e., plan sheet, note or detail number, calculation page, etc.
Please indicate here if any changes have been made to the plans that are not a result
of corrections from this list. If there are other changes, please briefly describe them
and where they are located in the plans.
• Have changes been made to the plans not resulting from this correction list?
Please indicate:
Yes □ No □
The jurisdiction has contracted with EsGil, located at 9320 Chesapeake Drive, Suite
208, San Diego, California 92123; telephone number of 858/560-1468, to perform the
plan review for your project. If you have any questions regarding these plan review
items, please contact Abe Doliente at EsGil. Thank you.
Carlsbad CBR2018-1303
June 12, 2018
[DO NOT PAY -THIS IS NOT AN INVOICE]
VALUATION AND PLAN CHECK FEE
JURISDICTION: Carlsbad
PREPARED BY: Abe Doliente
BUILDING ADDRESS: 2788 James Dr
BUILDING OCCUPANCY: R3/U
BUILDING AREA Valuation
PORTION ( Sq. Ft.) Multiplier
Addition 132 169.50
Air Conditioning
Fire Sprinklers
TOTAL VALUE
Jurisdiction Code cb By Ordinance
1997 UB~~uildi~g-~ermit_F_:~-~--•]
Type of Review:
D Repetitive Fee ~J Repeats
Comments:
Complete Review
D Other
□ Hourly
EsGil Fee
PLAN CHECK#.: CBR2018-1303
DATE: June 12, 2018
Reg. VALUE ($)
Mod.
22,374
22,374
D Structural Only
$131.041
Sheet 1 of 1
«,
~ CITY OF
CARLSBAD
PLANNING DIVISION
BUILDING PLAN CHECK
APPROVAL
P-29
DATE: 6/4/18 PROJECT NAME: ADDITION PROJECT ID:
Development Services
Planning Division
1635 Faraday Avenue
(760) 602-4610
www.carlsbadca.e:ov
JUN 1 8 2018
PLAN CHECK NO: CBR2O18-1303 SET#: ADDRESS: 2788 JAMES dRll )SN,F CARLSBAD
BUILDING DIVISION
0 This plan check review is complete and has been CONDITIONALLY APPROVED by
t he PLANNING Division. / t!!.. /4 4-i .. v ?(p • t • •00
By: GINA RUIZ !>.. _.... t...(j r "',, I 4-~ t 7
A Final Inspection by the PLANNING Division is required □ Yes [8:1 No
You may also have corrections from one or more of the divisions listed below. Approval
from these divisions may be required prior to the issuance of a building permit.
Resubmitted plans should include corrections from all divisions.
D This plan check review is NOT COMPLETE. Items missing or incorrect are listed on
the attached checklist. Please resubmit amended plans as required.
Plan Check Comments have been sent to: WRIGHTHAUS@ROADRUNNER.COM
For questions or clarifications on the attached checkllst please contact the following reviewer as marked:
PLANNING ENGINEERING FIRE PREVENTION
76~2-4610 760-602-2750 760-602-4665
□ Sarah Cluff □ 760-602-4619
t_.\~ Sarah.Cluff~!.i;!rls!2i;!dca.gov
~ Gina Ruiz □ <
760-602-4675 \..,.'> '/" . ./ Glni;!.Rulz~i;;arl~bs1dci;!.gov ,./'
□ Hector Salgado □ □ 760-602-4624
H~ctor .Si;! lgado~Cs! rlsbi;!dca.gov
Remarks: AREA TABULATION TABLE NEEDS TO BE REVISED TO REFLECT
CORRECT INFORMATION. (CAN BE HANDWRITTEN ON THE PLANS)
/~~I!.-,-. -,-..,._Cb"->'-,-. 1'\ ~'-' 0 ~
~1£..\J,~ ~o {
• -I ''-' ,.
STORM WATER POLLUTION PREVENTION NOTES
1. ALL NECESSARY EQUIPMENT AND MATERIALS SHALL BE
AVAILABLE ON SITE TO FACILITATE RAPID INSTALLATION
OF EROSION AND SEDIMENT CONTROL BMPs WHEN RAIN
IS EMINENT.
2. THE OWNER/CONTRACTOR SHALL RESTORE ALL EROSION
CONTROL DEVICES TO WORKING ORDER TO THE SATISFACTION
OF THE CITY INSPECTOR AFTER EACH RUN-OFF PRODUCING
RAINFALL.
3. THE OWNER/CONTRACTOR SHALL INSTALL ADDITIONAL EROSION
CONTROL MEASURES AS MAY BE REQUIRED BY THE CITY
INSPECTOR DUE TO INCOMPLETE GRADING OPERATIONS OR
UNFORESEEN CIRCUMSTANCES WHICH MAY ARISE.
4. ALL REMOVABLE PROTECTIVE DEVICES SHALL BE IN PLACE
AT THE END OF EACH WORKING DAY WHEN THE FIVE (5)
DAY RAIN PROBABILITY FORECAST EXCEEDS FORTY PECENT
( 40%). SILT AND OTHER DEBRIS SHALL BE REMOVED AFTER
EACH RAINFALL.
5. ALL GRAVEL BAGS SHALL CONTAIN 3/4 INCH MINIMUM
AGGREGATE.
6. ADEQUATE EROSION AND SEDIMENT CONTROL AND PERIMETER
PROTECTION BEST MANAGEMENT PRACTICE MEASURES MUST
BE INSTALLED AND MAINTAINED.
7. THE CITY INSPECTOR SHALL HAVE THE AUTHORITY TO ALTER
THIS PLAN DURING OR BEFORE CONSTRUCTION AS NEEDED
TO ENSURE COMPLIANCE WITH CITY STORM WATER QUALITY
REGULATIONS.
OWNER'S CERTIFICATE:
I UNDERSTAND AND ACKNOWLEDGE THAT I MUST: (1) IMPLEMENT
BEST MANAGEMENT PRACTICES (BMPS) DURING CONSTRUCTION
ACTIVlTIES TO lHE MAXIMUM EXTENT PRACTICABLE TO AVOID
THE MOBILIZATION OF POLLUTANTS SUCH AS SEDIMENT AND TO
AVOID THE EXPOSURE OF STORM WATER TO CONSTRUCTION
RELATED POLLUTANTS; AND (2) ADHERE TO, AND AT ALL TIMES,
COMPLY WITH THIS CITY APPROVED TIER 1 CONSTRUCTION SWPPP
THROUGHOUT lHE DURATION OF THE CONSlRUCTlON ACTIVITIES
UNTIL lHE CONSTRUCTION WORK IS COMPLETE AND APPROVED
BY THE CITY OF CARLSBAD.
S ~bf'J
E-29
STORM WATER COMPLIANCE FORM
TIER 1 CONSTRUCTION SWPPP
BEST MANAGEMENT PRACTICES (BMP) SELECTION TABLE
Erosion Control Sediment Control BMPs Tracking Non-Stom, Water Wafi.e Management and Materials
BMPs Control BMPs Management BMPs Pollution Control BMPs
C: ...., C: C: 0 ...... 0 .!2 :;:; C: C: "O :;:; ..... en 0 (I) -0 (I) -0 U) C: 0 0 C: C: en E C: E C: -0 -::, ::, 0 '5 ·;:: c.. 0 0 0 E (I) ... ... :;::; ... ·:5 (I)
:::E -0 U) 0, '----C: '->, 01
C: (I) ... .E (I) c Cl) U) U) !r! ·;:: O'" ... 0 C: c,, Oo c.. (I) ·c: C: (I) C: ... w -~ 0 Best Management Practice* ,;.:! .5 0 ID 0.. L.. 0 Q) 0 ... (!) Q) C: :;:;
rn 3= (I) i-= (I) 0 C: (.) (I) -(I) 0 ....., .c C: E (I) 0, ·a c: (.) ... U) -o rn ~ -0 a} (I) :::E C: Q) C: (BMP) Description ➔ (I) I,) (I) V) -~ (I) 1!! C'> ID 0, C: C: 0 => g;! ...., Q)
Q} "'5 ~Q> ...... 0 0 3: C: ... 0 ~~ -0 >, o rn c:: c:: 0 ~ E ~ I,) 0 0 ID (11 ·-O'> Cl,-00 0, (I) Cl) ::::!: Cl c> Cl C: C: E ~ 0 (.) (I) :§ :g, 15 = Q} ~ 0 -N (I) C'):,;:; (I) .__ 31: Q) X Q.) E :rl I,) .!!£ a. a. e (I) 0 Q.) LL. E ~ 1 ..... ::::, ..a = ~ =3= ._•-c:O ::0 ... 0 ·;:: ~ O'I --0 .c C: 0 ... Q) ::, -0 ·-v Q) -·-... 0 (.Jc:: (I) L (I) (.J ---0 C
0 0 -·-a. '6 (I) (I) Q) 0 C
.._....., .0 ... .0 0 ...... I,) i; 8 ·-0 ...., ~ C: LO 0 ..... 0 00 C 0\ .s 0 0 0 -.c (I) -0 0 = C: II) ~ 0 ... v5 (I) .c .0 ... ~o 0 -... VJ C: 31:C::: 0 ~o o-0 ..... a. 0 0 0
(!) WCl m (f) (.) ii: (!) (/)> (f) (f) 0.. (/)~ a..o a. ::::E (/j ::t: (f) ViU (/) :::i,
CASQA Desig1ation ➔ r---00 .... --t' Ii') tO r--co 0 N l'0 r--co .... N t'1 ...t-LO m 'T .... I") .... .... .-
I I I I I I I I I I I . I I I I I I I I I I I
(..) u (.) (.) w w w w w w w w ~ ~ en (/) (/) (J) ::::E ::::E j ::::E i Construction Activity w w w w (J) (f) en (I) (I) (/) (f) (I) z z: z: z 31: 31: 31:
It. Gradino/Soil Disturbance
y Trenchina/Excavation ·
StockoiHna
Drillina /Borina
Concrete/Asphalt Sawcutting
'I Concrete Flatwork
Pavina
X. Conduit/Pipe Installation
i Stucco7Mortor Work
Waste Disoosal
Staaina/Lav Dawn Area
Eouioment Maintenance and Fuelina
Hazardous Substance Use/Storaqe
Dew□terina
Site Access Across Dirt
Other (list):
Instructions:
1. Check the box to the left of all applicable construction activity (first column) expected to occur during construction.
2. Located along the top of the BMP Table is a list of BMP's with it's corresponding California Stormwoter Quality Association (CASQA) designation number. Choose one
or more BMPs you intend to use during construction from the list. Check the box where the chosen octivity row intersects with the BMP column.
3. Refer to the CASQA construction handbook for information and details of the chosen BMPs and how to apply them to the project.
PROJECT INFORMATION
Site Address: -z..., e B ~\!';s {ZIL-
Assessor's Parcel Number: I 5~ / lf L 4-'1 Dr)
Emergency C~ct: -~ ~ 1
Nome: ::..:, t.A,,-::,,ry /lt?vVt.' ll.Ji;;,L-,,
24 Hour Phone~ b / y-'f?,.,/..,. DBQ'],
Construction Threat to Storm Water Quality
(Check Box)
0 MEDIUM
(I) ....,
C/1 0 31:...,
C: UJ (I) ::::, E 0 Cl) 1:! O'I c,0 N C: 00 :r: :::E
<.P I
:::E 3::
Q.) ....,
U) 0...., 3::c: Q.)
(I) E _..., Q.) ~ 0,
I,) 0 c:: C: oo U:::E
<JO I i
Page 1 of 1 REV 11/17