Loading...
HomeMy WebLinkAbout2789 CREST DR; ; CB050841; Permitix \\<n 05-16-2005 Job Address: Permit Type: Parcel No: Valuation: Occupancy Group: # Dwelling Units: Bedrooms: Project Title: Applicant: DAVE STOCKEY City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Residential Permit Permit No: CB050841 Building Inspection Request Line (760) 602-2725 2789 CREST DR CBAD RESDNTL Sub Type: 1561524000 Lot#: $48,400.00 Construction Type: Reference #: 0 Structure Type: 0 Bathrooms: BERNARD RES-440SF DETACHED STUDIO/DEN RAD 0 NEW 4260 LINDA VISTA DR 92028 (760)728-6221 Status: Applied: Entered By: Plan Approved: Issued: Inspect Area: Orig PC#: Plan Check*: ISSUED 03/16/2005 LSM 05/16/2005 05/16/2005 Owner: BERNARD WILLIAM K&SUSAN E FAMILY TRUST 2789 CREST DR CARLSBAD CA 92008 Building Permit Add'l Building Permit Fee Plan Check Add'l Plan Check Fee Plan Check Discount Strong Motion Fee Park in Lieu Fee Park Fee LFM Fee Bridge Fee Other Bridge Fee BTD #2 Fee BTD #3 Fee Renewal Fee Add'l Renewal Fee Other Building Fee Pot. Water Con. Fee Meter Size Add'l Pot. Water Con. Fee Reel. Water Con. Fee $348.63 Meter Size $0.00 Add'l Red. Water Con. Fee $226.61 Meter Fee $0.00 SDCWA Fee $0.00 CFD Payoff Fee $4.84 PFF $0.00 PFF (CFD Fund) $0.00 License Tax $0.00 License Tax (CFD Fund) $0.00 Traffic Impact Fee $0.00 Traffic Impact (CFD Fund) $0.00 Sidewalk Fee $0.00 PLUMBING TOTAL $0.00 ELECTRICAL TOTAL $0.00 MECHANICAL TOTAL $0.00 Housing Impact Fee $0.00 Housing InLieu Fee Housing Credit Fee $0.00 Master Drainage Fee $0.00 Sewer Fee Additional Fees TOTAL PERMIT FEES $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $55.00 $20.00 $30.50 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $685.58 Total Fees:$685.58 Total Payments To Date:$226.61 Balance Due:$458.97 IN STORAGE ATTACHED 8349 05/16/05 0002 Oi 02 COP 458-97 Inspector:Clearance: NOTICE: Please take NflTlCE^hat approval of your project includes the "Imposition'' of fees, dedications, reservations, or other exactions hereafter collectively referred to as lees/exactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water end sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which vou have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired, CITY OF CARLSBAD BUILDING DEPARTMENT 1635 Faraday Ave., Carlsbad, CA 92008 FOR OFFICE USE ONLY PLAN CHECK NO. EST. VAL. Plan Ck. Deposit^ Validated By Date 3//fe»/QS . 6? I Business Name (at this address) Legal Description Lot No.Subdivision Name/Number Unit No.Phase No.Total # of units Assessor's Parcel #Existing Use 05 0002 01 02 Name ' Address City State/Zip Telephone # 5. CONTRACTOR - COMPANY NAME (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law [Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code] or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars l$500l). Name State License # Address License Class City State/Zip City Business License # Telephone # Designer Name State License # Address ft*w*>i;^i'"^r^" '- ^<:^rrr;.;"":i°'° ••••^•'•'^ ••.••.>.' -.:^"^-Hi;-''1- ;'-;^-K n ; ' r"fcJHvllp^rm^^" ^4^-"^' -'^' *' "'•':~''-'~ : '':';';^I-h:;: : :~v'';->''^>;:°:':":'i: City State/Zip 'pS;;;r'- r.M\ \?\f.:^:. Telephone "M r: ;i 1 i* J- J-">:":1; -»>:': •:•'. ™-.,;:; •<i-!<i:i- *•(„$ '•'•"''.;'•'• Workers' Compensation Declaration: I hereby affirm under penalty of perjury one of the following declarations: n I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. n I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My worker's compensation insurance carrier and policy number are: Insurance Company Policy No. Expiration Date (THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS [$100] OR LESS) D CERTIFICATE OF EXEMPTION: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. WARNING: Failure to secure workers' compensation coverage is unlawful, and shaH subject an employer to criminal penalties and civil fines up to one hundred thousand dollars ($100,000), in addition to the cost of compensation, damages as provided for in Section 3706 of the Labor code, interest and attorney's fees. SIGNATURE DATE I hereby affirm that I am exempt from the Contractor's License Law for the following reason: Q I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). Q I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). O I am exempt under Section Business and Professions Code for this reason: 1. I personally plan to provide the major labor and materials for construction of the proposed property improvement. Q YES QNO 2. t JWayfr^nave not) signed an application for a building permit for the proposed work. 3. I have contracted with the following person (firm) to provide the proposed construction (include name / address / phone number / contractors license number): 4. I plan to provide portions of the work, b.ut I have hired the followJng person to coordinate, supervise and provide the major work (include name / address / phonerk, but I ~7 •fc i£*Vg«"fc /<Mfnumber / contractors license number): 5. I will provide some of the work, but I have contracted (hired) t*e following persons to provide the work indicated (include name / address / phone number / type of work): DATEPROPERTY OWNER Is the applicant or future building occ\afa6t regaled to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections J(5505, 25£33 or >^534 of the Presley-Tanner Hazardous Substance Account Act? D YES Q NO Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? O YES Q NO Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? Q YES Q NO IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. AGENCY I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097(i) Civil Code). LENDER'S NAME LENDER'S ADDRESS I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all City ordinances and State laws relating to building construction. I hereby authorize representatives of the City of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: An OS HA permit is required for excavations over 5'0" deep and demolition or construction of structures over 3 stories in height. EXPIRATION: Every permit issued by the building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is not comme^a d within 180 days from the date of such permit or if the building or work authorized by such permit is suspended or abandoned a perjerfDj 180 days (Sectiop, 106.4.4 Uniform Building JJode). hte ILDATE /' at any lime alter the work is commencei \K-APPL1CANT'S SIGNATURE : Applicant City of Carlsbad Bldg Inspection Request For: 08/30/2005 Permit* CB050841 Title: BERNARD RES-440SF DETACHED Description: STUDIO/DEN Inspector Assignment: PS Type: RESDNTL Sub Type: RAD Job Address: 2789 CREST DR Suite: Lot 0 Location: APPLICANT DAVESTOCKEY Owner: BERNARD WILLIAM K&SUSAN E FAMILY TRUST 01-21-98 Remarks: Phone: 7602128177? Inspector: Total Time: CD Description 19 Final Structural 29 Final Plumbing 39 Final Electrical 49 Final Mechanical Requested By: SUE Entered By: CHRISTINE mment Associated PCRs/CVs Inspection History Date Description 08/23/2005 17 Interior Lath/Drywall 08/23/2005 89 Final Combo 07/25/2005 84 Rough Combo 07/20/2005 14 Frame/Steel/Bolting/Welding 07/20/2005 24 Rough/Topout 07/20/2005 34 Rough Electric 07/20/2005 44 Rough/Ducts/Dampers 07/11/2005 22 Sewer/Water Service 07/11/2005 23 Gas/Test/Repairs 07/11/2005 24 Rough/Topout 07/11/2005 31 Underground/Conduit-Wiring 07/11/2005 34 Rough Electric 06/24/2005 13 Shear Panels/HD's 06/17/2005 14 Frame/Steel/Bolting/Welding 06/17/2005 15 Roof/Reroof 05/20/2005 81 Underground Combo Act Insp Comments AP JM WALLS ONLY WC JM AP PS PA PS OK TO INSULATE CO PS NEED TEST PA PS WC PS AP PS AP PS WC PS AP PS WC PS AP PY WC PS AP PS AP PS EsGil Corporation In Partners/Up reitfi government for Quitting Safety DATE: 5/16/05 JURISDICTION: Carlsbad PLAN CHECK NO.: 05-0841 SET: H PROJECT ADDRESS: 2789 Crest Dr. PROJECT NAME: Residential Studio for Bernard Q APPLICANT Q JURIS. Q PLAN REVIEWER Q FILE The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. EH The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: Esgil Corporation staff did not advise the applicant that the plan check has been completed. Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Owner Phoned In Telephone #: owner Date contacted: 5/16/05 (by: CM) Fax #: Mail Telephone Fax In Perj {Zs^/jr ttached must be reviewed and approved by the city staff• REMARKS: The items lisle prior to permit issuance.' By: Chuck Mendenhall Esgil Corporation D GA D MB D EJ D PC Enclosures: Phone In & FAX In trnsmtl.dot 9320 Chesapeake Drive, Suite 208 4 San Diego, California 92123 + (858)560-1468 * Fax (858) 560-1576 Carlsbad 05-O841 5/16/05 "he instantaneous WH may not be located inside a cabinet or closet. These devices require free moving air surrounding the equipment to dissipate the heat. If you choose to leave the WH below the cabinet provide the manufacturers cut sheet for the device to show that it haj9 been approved for the proposed location. The electrical sub-panel may not be located in the closet as shown. LS The panel requires 30" deep clearance in front of the panel for a height of 6'-3" per the NEC. EsGil Corporation In yartnersfUp wtitfi government for lluiCtfinjj Safety DATE: 5/2/05 O&EEUQANT JURISDICTION: Carlsbad a PLAN REVIEWER a FILE PLAN CHECK NO.: 05-0841 SET: H PROJECT ADDRESS: 2789 Crest Dr. PROJECT NAME: Residential Studio for Bernard The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: Dave Stockey Designs 4260 Linda Vista Dr., Fallbrook, CA 92028 Esgil Corporation staff did not advise the applicant that the plan check has been completed. Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: pave Stockey Telephone #: (760) 728-6221 Date contacted:^ LHQb (by*^0) Fax #: Mail ^Telephone v^ Fax In Person REMARKS: By: Chuck Mendenhall Enclosures: Esgil Corporation D GA D MB D EJ D PC 4/25/05 tmsmtl.dot 9320 Chesapeake Drive, Suite 208 * San Diego, California 92123 * (858)560-1468 + Fax (858)560-1576 Carlsbad 05-0841 5/2/05 • Please make all corrections on the original tracings, as requested in the correction list. Submit three sets of plans for commercial/industrial projects (two sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92009, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. NOTE: The items listed below are from the previous correction list. These remaining items have not been adequately addressed. The numbers of the items are from the previous check list and may not necessarily be in sequence. The notes in bold are current. 3. The instantaneous gas water heater may not be located in a closet that opens into a sleeping room. The Studio is considered a dwelling unit. The water heater is not permitted in the cloths closet. The instantaneous WH may not be located inside a cabinet. These devices require free moving air surrounding the equipment to dissipate the heat. If you choose to leave the WH below the cabinet provide the manufacturers cut sheet for the device to show that it has been approved for the proposed location. 4. The composition shingles may not be installed on roof pitch less than 2:12 per UBC Table 15-B-1. The plans show you are intending to install the shingled on a 1.5:12 slope. The plans now show tile roof with BU roof. The design calc's were for composition shingles. Revise the design to include the weight of the tile and specify the manufacturer and ICBO approval number for the tile roof covering. • ELECTRICAL 8. Show on the plans the location of the subpanel serving this studio. Note that the subpanel will have a main disconnect for the building. The electrical subpanel may not be located in the closet as shown. The Carlsbad O5-0841 5/2/05 panel requires 30" deep clearance in front of the panel for a height of 6'-3"pertheNEC. To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Chuck Mendenhall at Esgil Corporation. Thank you. EsGil Corporation In <Partntrs/iip -nntfi (fovernmtnt for Quitting Safety DATE: 3/28/05 Q APPLICANT q^TDfiis^ JURISDICTION: Carlsbad a PTO Q FILE PLAN CHECK NO.: 05-0841 SET: I PROJECT ADDRESS: 2789 Crest Dr. PROJECT NAME: Residential Studio for Bernard The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: Dave Stockey Designs 4260 Linda Vista Dr., Fallbrook, CA 92028 Esgil Corporation staff did not advise the applicant that the plan check has been completed. Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Dave Stockey Telephone #: (760) 728-6221 Date contacted:&/WoS (by: £X) Fax #: -G221-/ Mail ^Telephone ^ Fax ^In Person REMARKS: By: Chuck Mendenhall Enclosures: Esgil Corporation D GA D MB n EJ PI PC 3/21/05 tmsmtl.** 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 4 (858)560-1468 4 Fax (858) 560-1576 Carlsbad O5-0841 3/28/05 PLAN REVIEW CORRECTION LIST SINGLE FAMILY DWELLINGS AND DUPLEXES PLAN CHECK NO.: O5-0841 JURISDICTION: Carlsbad PROJECT ADDRESS: 2789 Crest Dr. FLOOR AREA: 440 REMARKS: DATE PLANS RECEIVED BY JURISDICTION: DATE INITIAL PLAN REVIEW COMPLETED: 3/28/05 STORIES: one HEIGHT: lift DATE PLANS RECEIVED BY ESGIL CORPORATION: 3/21/05 PLAN REVIEWER: Chuck Mendenhall FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinance by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Present California law mandates that residential construction comply with the 2001 edition of the California Building Code (Title 24), which adopts the following model codes: 1997 UBC, 2000 UPC, 2000 UMC and 1999 NEC (all effective 11/1/02). The above regulations apply to residential construction, regardless of the code editions adopted by ordinance. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans. Carlsbad 05-0841 3/28/05 • Please make all corrections on the original tracings, as requested in the correction list. Submit three sets of plans for commercial/industrial projects (two sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92009, (760) 602- 2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. 1. Plans & specifications shall be signed and sealed by the California state licensed engineer or architect responsible for their preparation, for plans deviating from conventional wood frame construction. Specify expiration date of license. (California Business and Professions Code). 2. The studio is considered a dwelling unit. Provide a smoke detector within the Studio. 3. The instantaneous gas water heater may not be located in a closet that opens into a sleeping room. The Studio is considered a dwelling unit. The water heater is not permitted in the cloths closet. 4. The composition shingles may not be installed on roof pitch less than 2:12 per UBC Table 15-B-1. The plans show you are intending to install the shingled on a 1.5:12 slope. 5. Note on the foundation plan that a soil stamp from the City is required on the foundation plan prior to permit issuance in order to eliminate the need for a soil report per the City policy.. Carlsbad has ruled that a stand-alone accessory dwelling unit, if under 1000 square feet, may also qualify for this exception. 6. The energy form CF-1 r on sheet 1 must be signed by the owners and the energy designer, Ron Moore. 7. Specify on the window and door schedule the type of window glazing to show compliance with the energy design. ELECTRICAL 8. Show on the plans the location of the subpanel serving this studio. Note that the subpanel will have a main disconnect for the building. Carlsbad 05-0841 3/28/O5 9. Note on the plans that the subpanel serving the studio will be equipped with separate UFER ground and cold water pipe bond. To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Chuck Mendenhall at Esgil Corporation. Thank you. Carlsbad O5-O841 3/28/05 VALUATION AND PLAN CHECK FEE JURISDICTION: Carlsbad PLAN CHECK NO.: 05-0841 PREPARED BY: Chuck Mendenhall DATE: 3/28/05 BUILDING ADDRESS: 2789 Crest Dr. BUILDING OCCUPANCY: R3 TYPE OF CONSTRUCTION: VN BUILDING PORTION Studio Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code AREA (Sq.Ft.) 440 cb Valuation Multiplier City Est By Ordinance Reg. Mod. VALUE ($) 48,400 48,400 $348.63 Plan Check Fee by Ordinance Type of Review: Repetitive FeeRepeats Complete Review D Other -1 Hourly Structural Only Hour* Esgll Plan Review Fee $226.61 $195.23 Comments: Sheet 1 of 1 macvalue.doc City of Carlsbad Public Works - Engineering BUILDING PLANCHECK CHECKLIST DATE: BUILDING ADDRESS: _ PROJECT DESCRIPTION: ASSESSOR'S PARCEL NUMBER: PLANCHECK NO.: CB ENGINEERING DEPARTMENT APPROVAL EST VALUE: DENIAL The item you have submitted for review has been approved. The approval is based on plans, information and/or specifications provided in your submittal; therefore any changes to these items after this date, including field modifications, must be reviewed by this office to insure continued conformance with applicable codes. Please review carefully all comments attached, as failure to comply with instructions in this report can result in suspension of permit to build. D A Right-of-Way permit is required prior to construction of the following improvements: Please se»—the attached report of deficiencies marked With D-Maxe necessary corrections to plans or specmeatlGhs for compliance with applicable codes and standards. Submit corrected plans and/or specifications to this office for review. By: By: Date: Date: Date: FOR OFFICIAL USE ONLY ENGINEERING AUTHORIZATION TO ISSUE BUILDING PERMIT: By:Date: ATTACHMENTS D Dedication Application D Dedication Checklist D Improvement Application D Improvement Checklist D Future Improvement Agreement D Grading Permit Application D Grading Submittal Checklist D Right-of-Way Permit Application [J Right-of-Way Permit Submittal Checklist and Information Sheet U Sewer Fee Information Sheet ENGINEERING DEPT. CONTACT PERSON Name: TANIYA BARROWS City of Carlsbad Address: 1635 Faraday Avenue, Carlsbad, CA 92QQ8 Phone: (760) 602-2773 CFD INFORMATION Parcel Map No: Lots: Recordation: Carlsbad Tract: 1635 Faraday Avenue • Carlsbad, CA 92008-7314 • (76O) 6O2-272O • FAX (76O) 6O2-8562 REBUILDING PLANCHECK CKLST FORM -doc ,. R«v. 7/14/00 BUILDING PLANCHECK CHECKLIST SITE PLAN 1s7/ 2ND 3RD D D 1 • Provide a fully dimensioned site plan drawn to scale. Show: North Arrow F. Right-of-Way Width & Adjacent Streets Existing & Proposed Structures G. Driveway widths Existing Street Improvements H. Existing or proposed sewer lateral Property Lines I. Existing or proposed water service Easements J. Existing or proposed irrigation service Show on site plan: Drainage Patterns 1. Building pad surface drainage must maintain a minimum slope of one percent towards an adjoining street or an approved drainage course. 2. ADD THE FOLLOWING NOTE: "Finish grade will provide a minimum positive drainage of 2% to swale 5' away from building." B. Existing & Proposed Slopes and Topography C. Size, type, location, alignment of existing or proposed sewer and water service (s) that serves the project. Each unit requires a separate service, however, second dwelling units and apartment complexes are an exception. D. Sewer and water laterals should not be located within proposed driveways, per standards. [3 3. Include on title sheet: A. Site address B. Assessor's Parcel Number C. Legal Description For commercial/industrial buildings and tenant improvement projects, include: total building square footage with the square footage for each different use, existing sewer permits showing square footage of different uses (manufacturing, warehouse, office, etc.) previously approved. EXISTING PERMIT NUMBER DESCRIPTION F:«UILDINO PLANCHECK CKLST FORM Joe BUILDING PLANCHECK CHECKLIST 1s7 2ND 3RD DISCRETIONARY APPROVAL COMPLIANCE D D D 4a. Project does not comply with the following Engineering Conditions of approval for Project No. D D D 4b. All conditions are in compliance. Date: DEDICATION REQUIREMENTS PJ D D 5. Dedication for all street Rights-of-Way adjacent to the building site and any storm drain or utility easements on the building site is required for all new buildings and for remodels with a value at or exceeding $ 15.000 . pursuant to Carlsbad Municipal Code Section 18.40.030. Dedication required as follows: . Dedication required. Please have a registered Civil Engineer or Land Surveyor prepare the appropriate legal description together with an 8 14" x 11" plat map and 3 submit with a title report. All easement documents must be approved and signed by owner(s) prior to issuance of Building Permit. Attached please find an application form and submittal checklist for the dedication process. Submit the completed application form with the required checklist items and fees to the Engineering Department in person. Applications will not be accept by mail or fax. Dedication completed by: Date: IMPROVEMENT REQUIREMENTS D D D 6a. All needed public improvements upon and adjacent to the building site must be constructed at time of building construction whenever the value of the construction exceeds $ 75.000 . pursuant to Carlsbad Municipal Code Section 18.40.040. Public improvements required as follows: Attached please find an application form and submittal checklist for the public improvement requirements. A registered Civil Engineer must prepare the appropriate improvement plans and submit them together with the requirements on the attached checklist to the Engineering Department through a separate plan check process. The completed application form and the requirements on the F:«UILOIHO PLANCHECK CKLBT FORM.doc RD BUILDING PLANCHECK CHECKLIST checklist must be submitted in person. Applications by mail or fax are not accepted. Improvement plans must be approved, appropriate securities posted and fees paid prior to issuance of building permit. Improvement Plans signed by; Date: D D D 6b. Construction of the public improvements may be deferred pursuant to Carlsbad Municipal Code Section 18.40. Please submit a recent property title report or current grant deed on the property and processing fee of $360 so we may prepare the necessary Neighborhood Improvement Agreement. This agreement must be signed, notarized and approved by the City prior to issuance of a Building permit. Future public improvements required as follows: D D D 6c. Enclosed please find your Neighborhood Improvement Agreement. Please return agreement signed and notarized to the Engineering Department. Neighborhood Improvement Agreement completed by: Date: D 6d. No Public Improvements required. SPECIAL NOTE: Damaged or defective improvements found adjacent to building site must be repaired to the satisfaction of the Citv Inspector prior to occupancy. GRADING PERMIT REQUIREMENTS The conditions that invoke the need for a grading permit are found in Section 11.06.030 of the Municipal Code. D 7a. Inadequate information available on Site Plan to make a determination on grading requirements. Include accurate grading quantities (cut, fill import, export). D D D 7b. Grading Permit required. A separate grading plan prepared by a registered Civil Engineer must be submitted together with the completed application form attached. NOTE: The Grading Permit must be issued and rough grading approval obtained prior to issuance of a Building Permit. Grading Inspector sign off by: Date: D D D 7c. Graded Pad Certification required. (Note: Pad certification may be required even if a grading permit is not required.) REBUILDING PLANCHECK CKLST FORM.doc BUILDING PLANCHECK CHECKLIST ' *f £_xD Ed JZI 7d .No Grading Permit required. D 7e. If grading is not required, write "No Grading" on plot plan. MISCELLANEOUS PERMITS D D D 8. A RIGHT-OF-WAY PERMIT is required to do work in City Right-of-Way and/or private work adjacent to the public Right-of-Way. Types of work include, but are not limited to: street improvements, tree trimming, driveway construction, tying into public storm drain, sewer and water utilities. Right-of-Way permit required for: O D D 9. INDUSTRIAL WASTE PERMIT If your facility is located in the City of Carlsbad sewer service area, you need to contact the Carlsbad Municipal Water District, located at 5950 El Camino Real, Carlsbad, CA 92008. District personnel can provide forms and assistance, and will check to see if your business enterprise is on the EWA Exempt List. You may telephone (760) 438-2722, extension 7153, for assistance. Industrial Waste permit accepted by: Date: ODD 10.NPDES PERMIT Complies with the City's requirements of the National Pollutant Discharge Elimination System (NPDES) permit. The applicant shall provide best management practices to reduce surface pollutants to an acceptable level prior to discharge to sensitive areas. Plans for such improvements shall be approved by the City Engineer prior to issuance of grading or building permit, whichever occurs first. D D 11. D Required fees are attached required WATER METER REVIEW D D D 12a. Domestic (potable) Use Ensure that the meter proposed by the owner/developer is not oversized. Oversized meters are inaccurate during low-flow conditions. If it is oversized, for the life of the meter, the City will not accurately bill the owner for the water used. • All single family dwelling units received "standard" 1" service with 5/8" service. FMWUXNG PLANCHECK CKLST FORM.** BUILDING PLANCHECK CHECKLIST iST ,ND ,RD • If owner/developer proposes a size other than the "standard", then owner/developer must provide potable water demand calculations, which include total fixture counts and maximum water demand in gallons per minute (gpm). A typical fixture count and water demand worksheet is attached. Once the gpm is provided, check against the "meter sizing schedule" to verify the anticipated meter size for the unit. • Maximum service and meter size is a 2" service with a 2" meter. • If a developer is proposing a meter greater than 2", suggest the installation of multiple 2" services as needed to provide the anticipated demand, (manifolds are considered on case by case basis to limit multiple trenching into the street). 12b. Irrigation Use (where recycled water is not available) All irrigation meters must be sized via irrigation calculations (in gpm) prior to approval. The developer must provide these calculations. Please follow these guidelines: 1. If the project is a newer development (newer than 1998), check the recent improvement plans and observe if the new irrigation service is reflected on the improvement sheets. If so, at the water meter station, the demand in gpm may be listed there. Irrigation services are listed with a circled "I", and potable water is typically a circled "W. The irrigation service should look like: STA1+00 Install 2" service and 2. 3. 1.5: meter (estimated 100 gpm) If the improvement plans do not list the irrigation meter and the service/meter will be installed via another instrument such as the building plans or grading plans (w/ a right of way permit of course), then the applicant must provide irrigation calculations for estimated worst-case irrigation demand (largest zone with the farthest reach). Typically, Larry Black has already reviewed this if landscape plans have been prepared, but the applicant must provide the calculations to you for your use. Once you have received a good example of irrigation calculations, keep a set for your reference, in general the calculations will include: • Hydraulic grade line • Elevation at point of connection (POC) • Pressure at POC in pounds per square inch (PSI) • Worse case zone (largest, farthest away from valve • Total Sprinkler heads listed (with gpm use per head) • Include a 10% residual pressure at point of connection In general, all major sloped areas of a subdivision/project are to be irrigated via separate irrigation meters (unless the project is only SFD with no HOA). As long as the project is located within the City recycled water FiWUILCMNQ PLANCHECK CKLST FORM.doc BUILDING PLANCHECK CHECKLIST 1s1 2ND 3RD service boundary, the City intends on switching these irrigation services/meters to a new recycled water line in the future. D D D 12c. Irrigation Use (where recycled water is available) 1. Recycled water meters are sized the same as the irrigation meter above. 2. If a project fronts a street with recycled water, then they should be connecting to this line to irrigate slopes within the development. For subdivisions, this should have been identified, and implemented on the improvement plans. Installing recycled water meters is a benefit for the applicant since they are exempt from paying the San Diego County Water Capacity fees. However, if they front a street which the recycled water is there, but is not live (sometimes they are charged with potable water until recycled water is available), then the applicant must pay the San Diego Water Capacity Charge. If within three years, the recycled water line is charged with recycled water by CMWD, then the applicant can apply for a refund to the San Diego County Water Authority (SDCWA) for a refund. However, let the applicant know that we cannot guarantee the refund, and they must deal with the SDCWA for this. ODD 13. Additional Comments: F:18UILCMNO PLANCHECK CKLST FORM.doc k fe £• £• £ess PLANNING DEPARTMENT BUILDING PLAN CHECK REVIEW CHECKLIST Plan Check rio.£B Planner APN: _ Address Phone (760) 602- Net Project Density: CFD (in/owJDate of participation; Facilities Management Zone: Remaining net dev acresC Circle One (For non-residential development: Type of land used created by this permit . ! _—'. ) III Leoend:^ B Item Complete D "em Incomplete - Needs your action Ki rn f-j Environmental Review Required: YES NO Jff_ TYPE _^ ; DATE OF COMPLETION: . Compliance with conditions of approval? If not, state conditions which require action. Conditions of Approval: IB D D Discretionary Action Required: APPROVAURESO. NO. PROJECT NO. YES NO 2L.TYPE OTHER RELATED CASES: Compliance with conditions or approval? If not, state conditions which require action. Conditions of Approval: „ : — Q . Coastal Zone Assessment/Compliance Project site located in Coastal Zone? YES NO CA Coastal Commission Authority? YES NO ^_ If California Coastal Commission Authority: Contact them at- 7575 Metropolitan Drive, Suite 103, San Diego CA 92108-4402; (619) 767-2370 Determine status (Coastal Permit Required or Exempt): ' *. Coastal Permit Determination Form already completed? YES NC^\ . if NO, complete Coastal Permit Determination Form now. Coastal Permit Determination Log #: _ Follow-Up Actions: Stamp Building Plans as "Exempt" or "Coastal Permit Required" (at minimum Floor Plans). Complete Coastal Permit Determination Log as needed. D 2) [] Inclusionary Housing Fee required: YES NO (Effective date of Inclusionary Housing Ordinance - May 2T/1993.) Data Entry Completed? YES NO (A/P/Ds. Activity Maintenance, enter CB#, toolbar, Screens, Housing Fees, Construct Housing Y/N( Enter Fee, UPDATEI) Site Plan: H:\ADMII^eOUNTEF^BWgPlnchkRevChkl8t FtovWDV FROM :STQCKEY FAX NO. :7607286224 MIKE SURPREIWHT * flSSO Fax,1-619-531 0759 May. 13 2005 11:13AM P2 May 10 2006 00: Won HIU1/UU1 MIKE 8URPRENANT ft ASSOCIATES Coarattiuf Structural E&glaeen M*y06,2005 Chuck Mendeaholl ElgB Corporation 9320 CbawpMbi Dz. Stc. 208 San Dlcgo.CA 92123 Project/No.: Bernard Accessory Unit / 05042 2789 Crwt Drive Catlpbad, California In accordance with your rapcitt we hive icriemreJ die mod recent ntuctund drawings uid out donga calculation* for du AbovW nfttaooBd project SpeoflctJQy, we were ttked to wrlcw the documents with leaped to the propcwed roofing fiftiuh. The aoffoal calculations wen buad on A compoiira roofing 6nish (ut weight = S.Optf), however, we undeatand tttt tho owner would prefiez to uu caocxatB die fitfih (e*t weight - 10.0 piQ. Bftsed upon A review of out docunusoti foe thix ptoj«ct, we have determined tiitt the origfaul Taetiecl Mud kteol-kMd ctlcuUrions, and die •tnictiml monberf, zenuio adequtt* For the concrete die roofing finish (10.0 pif max)- We lealue that there may be tome itetni of latttett to you lhac have not been diicusied in thii letter. Therefore, we enooucago you to call with my additional queuioat you ramy have. ReipectfuUy MikeS 338 18th Mfoat tea Dlafo. CriUbnfe OaiOl Tri.(610) BflLOTUS FROM :STQCKEY FAX NO. : 7607286224 May. 13 2005 11:12PM PI FAX 4260 CINt»A VISTA I £f NS, I ktC. TO: N 2^4^- -TS INCLUDING COVER,: -> t+4*4f MIKE SURPRENANT & ASSOCIATES Consulting Structural Engineers STRUCTURAL CALCULATIONS Project: Bernard Accessory Unit San Diego, California Prepared for: Dave Stockey Designs 4260 Linda Vista Drive Fallbrook, California 92028 Project No.: 05042 Date: March 9,2005 335 15th Street San Diego, California 92101 Tel. (619) 531.0757- Pax. (619) 531.0758 , ft f\ .H. *"~ ^\ f-J>l I \QJ&> O^ O1S?4] JOB MIKESURPRENANT / & ASSOCIATES SHECTNO — OF- Consulting Structural Engineers CALCULATED BY Ju^. DATE. CHECKED BY DATE. SCALE TABLE OF CONTENTS L PROJECT SCOPE 2. DESIGN CRITERIA SUMMARY. PAGE 2 3. DESIGNLOADS Z. 4. VERTICAL ANALYSIS: A. HORIZONTAL MEMBER DESIGN (BEAMS, HEADERS, JOISTS, ETC.) §_ B. VERTICAL MEMBER DESIGN (COLUMNS, STUDS, ETC.) ^_ 5. LATERAL ANALYSIS: A. SEISMIC /WIND LOADS fc_ B. LATERAL LOAD DISTRIBUTION - C. LATERAL LOAD-RESISTING DESIGN: I. SHEARWALL DESIGN _?-& H. CANTILEVERED STEEL COLUMN ELEMENTS " IH. STEEL MOMENT FRAMES _ - D. REDUNDANCY FACTOR VERIFICATION _ 3 6. FOUNDATION DESIGN: A. CONTINUOUS FOOTINGS A*// B. SPREAD FOOTINGS ft C. RETAINING WALLS _ ^ D. SPECIAL SYSTEMS , . ^ I. GRADE BEAMS _ H. DEEPENED PIERS *" 7. SCHEDULES./5 A. SHEARWALL SCHEDULE ................................................................... _H B. HOLD DOWN SCHEDULE ................................................................... /* C. SIMPSON STRONGWALL SCHEDULE D. SPREAD FOOTING SCHEDULE ........................................................... IT JOB™ MIKE SURPRENANT SHEETNO ~_ OF—Lj. & ASSOCIATES CALCULATED BY — DATE Consulting Structural Engineers CHECKED BY __ DATE SCALE PROJECT SCOPE Provide vertical & lateral load calculations for a proposed 420 sq. ft. one-story Accessory Unit to be constructed in San Diego, California. Residence to be constructed utilizing primarily wood-frame construction. Roof framing to consist of conventional "stick-frame", and the foundation system to consist of a conventional concrete slab-on-grade with deepened perimeter footings. A soils report was not provided for this project. Therefore, the foundation design will be based on the minimum soil bearing capacity as specified in the current version of the Uniform Building Code (UBC). Mike Surprenant & Associates makes no representations concerning the suitability of the soils and/or minimum soil values allowed by the UBC. These calculations have been prepared for the exclusive use of Mr. Dave Stockey and his design consultants for the specific site listed above. Should modifications be made to the project subsequent to the preparation of these calculations, Mike Surprenant & Associates should be notified to review the modifications with respect to the recommendations/conclusions provided herein, to determine if any additional calculations and/or recommendations are necessary. Our professional services have been performed, our findings obtained, and our recommendations prepared in accordance with generally accepted engineering principles and practices. PRODUCT 207 'iBfaair1 MIKE SURPRENANT ir \1T & ASSOCIATES 1^1 \sSg. Consulting Structural Engineers SWFPT Wn r.4ir.ui4TFpRV rnf=rKPn RV ST.AI P ? o, H HATP RATF GOVERNING CODE: CONCRETE: MASONRY: MORTAR: GROUT: REINFORCING STEEL: STRUCTURAL STEEL: WELDING: SAWN LUMBER: MOISTS: MICROLLAMS/ PARALLAMS/ TIMBERSTRAND GLULAMS: SOIL: DESIGN CRITERIA SUMMARY 2001 C.B.C. f c = 2500 PSI, NO SPECIAL INSPECTION REQ'D, (U.N.O.) ASTM C90, f m = 1500 PSI, NO SPECIAL INSPECTION REQ'D, (U.N.O.) ASTM C270, f c = 1800 PSI, TYPE S ASTM C476, f c = 2000 PSI ASTM A615, Fy = 40 KSI FOR #3 AND SMALLER ASTM A615, Fy = 60 KSI FOR #4 AND LARGER (U.N.O.) ASTM A992, Fy = 50 KSI (ALL 'W SHAPES, ONLY) ASTM A36, Fy = 36 KSI (STRUCTURAL PLATES, ANGLES, CHANNELS) ASTM A500, GRADE B, Fy = 46 KSI (STRUCTURAL TUBES-HSS) ASTM A53, GRADE B, Fy = 35 KSI (STRUCTURAL PIPES) E70-T6-TYP. FOR STRUCTURAL STEEL E90 SERIES FOR A615 GRADE 60 REINFORCING BARS DOUG FIR LARCH, ALLOWABLE UNIT STRESSES PER 1997 UBC. TrusJoist MacMillan - ICBO PFC-4354 (TJI & TJI/PRO MEMBERS) TrusJoist MacMillan - ICBO PFC-4354 - (LVL/PSL/LSL MEMBERS) DOUGLAS FIR OR DOUGLAS FIR/HEM GRADE 24F-V4 (SIMPLE SPANS) GRADE 24F-V8 (CANTILEVERS) Q^EXEXISTING NATURAL SOIL VALUES PER UBC TABLE 18-I-A SOIL CLASSIFICATION - % SOILS REPORT BY: DATED: ALLOWABLE BEARING PRESSURE ACTIVE SOIL PRESSURE (CANTILEVER) ACTIVE SOIL PRESSURE (RESTRAINED) PASSIVE SOIL PRESSURE COEFFICIENT OF FRICTION /OOP _PSF _PCF _PCF PCF MIKE SURPRENANT & ASSOCIATES Consulting Structural Engineers JOB. SHEET NO., CALCULATED BY_ CHECKED BY SCALE DATE. DATE. DESIGN LOADS ROOF DEAD LOAD: ROOFING MATERIAL SHEATHING RAFTERS/CJ. (or) TRUSSES .... INSULATION DRYWALL OTHER (ELEC, MEOL, MISC.) TOTAL DEAD LOAD: LIVE LOAD: TOTAL LOAD: MATERIAL: SLOPE: PSF FLOOR DECK FLOOR /' /JL MATERIAL: DEAD LOAD: FLOORING FINISH PSF PSF LT. WEIGHT CONCRETE ( in.) SHEATHING 2.0 2.0 JOISTS 3.5 3.5 DRYWALL 2.5 2.5 OTHER (ELEC., MECH., MISC.) 3.0 3.0 TOTAL DEAD LOAD: .0 PSF .0 PSF LIVE LOAD: .0 PSF .0 PSF TOTAL LOAD: .0 PSF .0 PSF EXTERIOR WALL FINISH: TJWtv* STUDS 1.0 PSF 1.0 PSF DRYWALL 2.5 2.5 INSULATION 1.5 1.5 EXTERIOR FINISH Jo.O .0 OTHER 1.0 1.0 TOTAL LOAD: /to .0 PSF .0 PSF INTERIOR WALL STUDS 1.0 PSF DRYWALL 5.0 OTHER U TOTAL LOAD: PRODUCT 207 MIKE SURPRENANT & ASSOCIATES Consulting Structural Engineers JOB. SHEET NO—OF. CALCULATED BY_ CHECKED BY SCALE . DATE. DATE. LEVEL: Td MEMBERS: h LABEL: /^H B^ UNIFORM LOAD d POINT LOAD (CEf D CUSTOM LOADIN p „ Pi = USE: iM* ALT: HORIZONTAL MEMBER DESIGN <CfW\$ SPAN= \l£ FT. •JTF,RET>) r-- - - U (SKfa DIAGRAM) * ) ~* 3TO^W" S R, - 2ZH> Ibs VMAX = * Ibs MMAX= ^Ot» ft-Ibs GRADE: PTlK- C: » GRADE: C: *i ss E = A»«»D ksi IREO'D = 1* f in4 LABEL: D UNIFORM LOAD D POINT LOAD (CEh D CUSTOM LOADIN Pi =p _. USE: ALT: SPAN= FT. ITERED) Rr= Ibs VMAX = Ibs MHAX= ft-lbs GRADE: C: GRADE: C: ^ RB » Ibs E = ksi IREO'D = in4 LABEL: D UNIFORM LOAD D POINT LOAD (CBN D CUSTOM LOADIN Wi- W2 = P2 = USE: ALT: SPAN= FT. ITERED) f R,= Ibs VMAX = Ibs MMAX= ft-Ibs GRADE: C: GRADE: C: s Rp = Ibs E = ksi IREO'D = in4 PRODUCT 207 <UjW^ MIKE SURPRENANT Ji \ 1 & ASSOCIATES r^*i ygh-L. Consulting Structural Engineers'%.-.• r \ i fiHPFTMCl C.U.CAH ATED BY r.UFC.K FO BY SPJVLP & HP ^1 HATP OATE AREA: Seismic: V = (Z5GJ/R)Wt - (Governs) Seismic Zone Soil Profile = I =1.0 (Standard Occupancy) R =_^I_ Wt = Total Seismic Dead Load BASE SHEAR: V = Jk/8fe_W( (ASDLoad) (Assume p = 1.0, Verification to Follow) LATERAL ANALYSIS / DESIGN (SEISMIC / WIND LOADS) Wind: P = CeCqq,I Method_JV_ h-~a U»<=> ft Exposure "& Basic Wind Speed - UBC Table 16-G . UBC Table 16-H psf = U- T mph Cq = Iw = 1.0 (Non-Essential Facility) 0*01 *LBS Exterior Wall Weight =, debt» Ir/ LBS Interior Wall Weight Total Weight (Tributary to Diaphragm) -. FLOOR WEIGHT Diaphragm =. = x/i. Exterior Wall Weight =. Interior Wall Weight = . Total Weight (Tributary to Diaphragm) = FLOOR WEIGHT: Diaphragm = Exterior Wall Weight = Interior Wall Weight = . Total Weight (Tributary to Diaphragm) = TOTAL DEAD LOAD, Wt = BASE SHEAR, V = fl./fffr Wt = UNIT SHEAR, v = V /Area (Applies to single level structures only) =, _LBS _LBS _LBS .LBS .LBS .LBS .LBS .LBS .LBS .LBS .LBS PSF DD If on DD D tfDD fcfnn JSTDD 1. Provide a fully dimensional site plan drawn to scale. Show:. North arrow, property lines, easements, existing and proposed structures, streets, existing street improvements, right-of-way width, dimensional setbacks and existing topographical lines (including all side and rear yard slopes). 2. Provide legal description of property and assessor's parcel number. Policy 44 - Neighborhood Architectu 1. Applicability: YES _ NO. 2. Project complies YES _ _NO_ Design Guidelines Zoning: -\. Setbacks: Front: . Interior Side: Street Side: . Rear Top of slope: 2. Accessory structure set! Front: Interior Side: Street Side: Rear: Structure separation: 3. Lot Coverage: Required Required Required Required Required _ Dacks: Required Required , Required Required Required Required Shown Shown Shown Shown Shown . ... ifl Shown ^ - Shown 7/2 Shown Tjp Shown jO Shown ^IfO ^Shown Xt-— 4?/o*y/5o 21 -T 4. Height Required Spaces Required, Shown Shown5. Parking: (breakdown by uses for commercial and industrial projects required) Residential Guest Spaces Required. ; Shown only ctiHuii* web OKTO ISSUE AND ENTERED APPROVAL INTO COMPUTER ^ H^ADMlN\COUNTCB«ldgPlnchkA«vChk)M // .enoM&i (w^efwk d*e*s-fee MIKE SURPRENANT & ASSOCIATES Consulting Structural Engineers ' ' DATE. DATE. SHEARWALL DESIGN / Storv Shearwalls ff'b Direction Unit Lateral Load, v = / /~Gridline / in )(I*K) Tributarv Area (This Level): V «-/VW>/ ~ Lateral Load (This Level): "~ Lateral Load (Level Above): ShearwalKs) Length. L = Unit Wall Shear, v = F,/L = /M olf Shearwall Type: (If Overturning: L = ft. Uplift = Holdown Anchor Type: i — i Cridline (V JfVJ \ Tributary Area (This Level): V/t/l 7*^7* Lateral Load (This Level): Lateral Load (Level Above): ShearwalH s) Length. L = Unit Wall Shear, v = F,/L = IW plf Shearwall Type: \ * f Overturning: L = ft. Uplift = Holdown Anchor Type: i — i Cridline , „ Tributarv Area fThis Level): Lateral Load (This Level): Lateral Load (Level Above): ShearwalKs) Length. L = Unit Wall Shear, v = Fr/L = plf Shearwall Tvpe: < t Overturning: L = ft. Uplift = Holdown Anchor Type: i — i Total Load (All Levels). F. =5,0ft. * Okav bv Inspection Lbs . Total Load (All Levels). F, =^,oft. Okav bv Inspection Lbs Total Load (All Levels). F. = ft. Okay by Inspection Lbs £-QJ» DSf 2/O sq. ft. /Jflf Lbs *" Lbs //B*I Lbs 2/ 1> sq. ft. J/W Lbs " Lbs Hit Lbs sq.ft. Lbs Lbs Lbs PRODUCT 207 MIKE SURPRENANT &ASSOaATES Consulting Structural Engineers JOB. SHEET NO.. CALCULATED BY_ CHECKED BY SCALE DATE. DATE. / Storv Shearwalls C "M)irection Unit Lateral Load, v = 5w ^ osf Gridline '^ Pi tfva \ Tributary Area (This Level): I '* /I T'O^ * Lateral Load fThis Level): Lateral Load (Level Above): Shearwallfs) Length. L = Unit Wall Shear, v = FJL = z**7- plf ( L*< Shearwall Type: \3y Overturning; L= A' ft. Uplift = WW W )•" Holdown AnchorType: rrn i, Ittl ?Tr/MD A s~Gridline U f n ]f „ . Tributary Area (This Level): V K'/V MO/» Lateral Load (This Level): Lateral Load (Level Above): Shearwallfs) Length. L = Unit Wall Shear, v = F,/L = 23* plf / 1 <3 Shearwall Type: \^/ Overturning: L = && ft.uplift = (z/ro) c^)-v Holdown Anchor Type: r7~\ \ Gridline Tributary Area ("This Level): Lateral Load (This Level): Lateral Load (Level Above): Shearwallfs) Length. L = Unit Wall Shear, v = F,/L = plf Shearwall Type: ( t Overturning: L = ft. Uplift = Holdown Anchor Type: i — i 2/0 sa.ft. IIW Lbs *" Lbs Total Load f All Levels). F, = /ftf Lbs 7X> ft. Ot^r 1 '•**') v 3&2, W/f * Okav bv Inspection &TM Lbs * 2K> sq.ft. /I for Lbs - Lbs Total Load f All Levels). FT= //#? Lbs ^"«O ft. rr»»"- \ ^v*** Okay by Inspection I'W-' Lbs sq.ft. Lbs Lbs Total Load (All Levels). F, = Lbs ft. Okay by Inspection Lbs PRODUCT Z07 JOS , MIKESURPRENANT Q n SHEET NO. L_ OF I _\_& ASSOCIATES Consulting Structural Engineers CALCULATED BY DATE. CHECKED BY DATE. SCALE REDUNDANCY FACTOR CALCULATION (UBC 1630.1.1) FLEXIBLE DIAPHRAGM WITH WOOD STRUCTURAL PANEL SHEARWALLS Vmax = /I/I Lbs (Total lateral load at Gridline f*~ ") lw = '* ft (Total Sum of Lengths of Shearwalls at Gridline) F = ^W Lbs (Story Shear) AB = T^O sq.ft. (Ground Floor Area of Structure) CALCULATIONS: *max rrmax 2-Q = 7- qtrito = ^- > O OKAY PROOUCT207 MIKE SURPRJENANT & ASSOCIATES Consulting Structural Engineers JOB, SHEET NO.. CALCULATED BY_ CHECKED BY SCALE DATE. DATE- FOUNDATION DESIGN ALLOWABLE APPLIED LOADS Allowable Soil Bearing Pressure (ASBP) =psf (Per Design Criteria) CONTINUOUS FOOTINGS |wB MARK: CF-1 Ftg. Width (b) = A° ft. WALLOW = ASBP (b) = Depth of Ftg. (h) =ft. USE: Ms" WIDEx_&, MDEEP. WITH #TOP & BOTTOM MARK: CF-2 Ftg. Width (b) = _.ft. Depth of Ftg. (h) =.ft. _plf USE:WIDEx DEEP. WITH #TOP & BOTTOM WMAX @ Gridline tir WMAX @ Gridline WMAX @ Gridline WMAX @ Gridline USE: CF- L USE: CF- USE: CF- USE: CF- D PRODUCTZ07 MIKE SURPRENANT & ASSOCIATES Consulting Structural Engineers JOB. SHEET NO.\1 CALCULATED BY_ CHECKED BY SCALE DATE. DATE. CONTINUOUS FOOTINGS - MAX POST LOADS MARK: CF-1 PMAX = ASBP(bX2h) =_ MARK: £££ PMAX = ASBP(b)(2h) =. 2h (ft.) h(ft.) 2ooo LBS. LBS. D PRODUCT 207 MIKE SURPRENANT & ASSOCIATES Consulting Structural Engineers JOB. SHEET NO..n CALCULATED BY. CHECKED BY SCALE DATE. DATE. SPREAD FOOTINGS - MAX. ALLOWABLE CONCENTRATED LOADS PMAX bflU PMAX = ASBP (b)2 =LBS. h(ft.) USE: 24" SQUARE x fa " DEEP WITH (2) # 4 EACH WAY @ BOTTOM MARK: P-2 PMAX = ASBP (b)2 =LBS USE: 30" SQUARE x J V " DEEP WITH (3) # 4 EACH WAY @ BOTTOM MARK: P-3 PMAX =ASBP(b)2 = USE: 36" SQUARE x )\. " DEEP WITH (4) # 4 EACH WAY @ BOTTOM MARK:M =ASBP(b)2 =LBS. USE: 42" SQUARE x /«, " DEEP WITH (5) # 4 EACH WAY @ BOTTOM PMAX =ASBP(b)2 =LBS. USE: 48" SQUARE x / V " DEEP WITH (6) # 4 EACH WAY @ BOTTOM D PRODUCT 207 JOB. MIKESURPRENANT « ,-j & ASSOCIATES SHEET N0 Consulting Structural Engineers CALCULATED BY DATE. CHECKED BY DATE. SCALE SCHEDULES MIKE SURPRENANT & ASSOCIATES Consulting Structural Engineers JOB. SHEET NO.. CALCULATED BY. CHECKED BY SCALE A_OP \1 DATE. DATE. a>sS* o § <$>. u tg ® MIKESURPRENANT & ASSOCIATES Consulting Structural Engineers JOB. SHEET NO.. CALCULATED BY- CHECKED BY SCALE DATE. DATE. HOLD-DOWN SCHEDULE ri 4x POST W MSTC40 FLR-To-FLR HOLD-DOWN 4x POST W MSTC52 FLR-To-FLR HOLD-DOWN 4x POST W/ MSTC66 FLR-To-FLR HOLD-DOWN 4x POST W/ MSTC7B aR-To-FLR HOLD-DOWN 4x POST W CMST14 FLR-To-FLR HOLD-DOWN (341 END LENGTH * (74) 16d TO EA. POST) 4x POST W/ CMSTI2 FLR-To-FLR HOLD-DOWN (45' END LENGTH * (\00) 16d TO EA. POST) 4x POST W/ STHD8 HOLD-DOWN 4x POST W STHD10 HOLD-DOWN 4x POST W/ STHD14 HOLD-DOWN 4x POST W/ PHD2 ON SSTBI6 A.B. 4x POST W/ PHD5 ON SSTB24 A.B. 4x POST W/ PHD6 ON SSTB28 A.B. 4x POST W PHD8 ON SSTB2& A.B. 4x POST W HD8A ON SSTB28 A.B. 4x POST W/ HDIOA ON SSTB26 A.B. 4x POST W/ HDI4A ON SSTB34 A.B. NOTES: 0 HOLD DOWN ANCHORS MUST BE TIED IN PLACE PRIOR TO FOUNDATION INSPECTION. 2) DEEPEN FOOTINGS TO PROVIDE 3' M1N. CONCRETE COVER WHERE MOLD DOWN ANCHORS ARE LONGER THAN THE FTG DEPTH. 3; USE CRJ; OPTION ON STHD HOLD-DOWNS FOR RAISED WOODSUB-FLOOR CONDITION. REV. JAN. 2001 PRODUCT 207 MIKE SURPREN ANT & ASSOCIATES Consulting Structural Engineers JOB, SHEET NO. CALCULATED BY_ CHECKED BY SCALE OF DATE. DATE. SIMPSON STRONGWALL R=V. 6EP. A SW6xt-4HD SUJIfexl-fcHD 5UHfex8-4WD SUJ22x1-4 6002x1-6 8052x8-4 t-l 30122x8-6 6UJI8x8 6U!24x8 5082x8 N 50)18x9 60)24x9 80B2x9 SUM8x9 80124x10 60)32x10 V 60)48x10 OJ 50C4xl2x6 6082x12x6 SIMPSON STRONSUJALL FOOTNOTES: 'APPLY ICBO ' FFC-W8& FOR SINGLE FOUR APPLICATIONS, USE 35TB2S MOLPOlW ANCHOR BOLTS WD W x G1 fMHJ MUDSILL 4NCHOR&. Efl^^ PLACE ALL ANCHORS USING A &TBONSUWLL TEMPLATE APPROPRIATE FOR THE APPLICATION AND LENSTH OF IIWU. FOR EXTERIOR APPLICATIONS, USE W TYPE TEMPLATES FOR INTERIOR ApaiCATIONS, USE 'SIUTI1 TYPE TEMPLATES FOR PANEL FORM APPLICATIONS, USE 'SUflPF TYPE TEMPLATES USE ALL PROVIDED HARDWARE FOR ANCHORAGE TO FOWDATION. USE PROVIDED SCREWS AND SUM <F PROVIDED; FOR CONNECTION TO DEL TOP PLATE FOR GARAGE PORTALS, CONNECT 4X12 fMNJMEADER AT TOP CF IU4LL WTH PROVIDED SCREWS, PROVIDED T1ST1 STRAP WITH < W) &d COMMONS, AND PANEL EXTENSION WITH I0d COMMONS * 3' o/c. fVERTJ * 4' o/c. ^HORIZJ NO HOLES, NOTCHES, CUTS, OR OTHER MODF1CATICN8 SHALL BE MADE TO THE 5TRONGUWLL N ANY CASE EXCEPT AS PERMITTED SY SIMPSON STRONG-TIE, frC. AND ICBO REPORT. -ff DENOTES RAISED FLOOR OPTICN Or &TRONGUWLL PLEASE MAKE NOTE OF THIS IUHEN ORDERING MATERIALS. ALL -RF MODEL STROMGWALLS SHALL USE A SIMPSON TIP 1/6-1' fNOT SUPPLIED; AT EACH HOLDOUN ANCHOR PRODUCT 307 MIKE SURPRENANT & ASSOCIATES Consulting Structural Engineers JOB. SHEET NO.. CALCULATED BY. CHECKED BY SCALE DATE. DATE. SPREAD FOOTING SCHEDULE SYMBOL <&><s><s><s> <8> SIZE AND REINFORCEMENT (fc -2,500 pal 4 fy&0kii; 24" SQUARE X /t- " 30" SQUARE X /i- " 36" SQUARE X J2/ 42" SQUARE X /^ ' 4&1 SQUARE X ^ ' DEEP W (2) DEEP W/ ("3; DEEP W/ (4) DEEP W/ (5J DEEP W/ C6; * A EACH WAT * 4 EACH WAT » 4 EACH WAY * 4 EACH WAY # 4 EACH WAY Title BERNARD STUDIO Date. .03/10/05 08:28:46 Project Address 2789 CREST DRIVE ******* CARLSBAD, CA *v6.01* I I Documentation Author... RON MOORE ******* | Building Permit # I Ron Moore Title 24 Energy Calcs. I . I 4152 Chasin Street I Plan Check / Date I Oceanside, CA 92056 I I 760-806-1026 I Field Check/ Date I Climate Zone 07 Compliance Method MICROPAS6 v6.01 for 2001 Standards by Enercomp, Inc. I MICROPAS6 v6.01 File-BERNARD Wth-CTZ07S92 Program-FORM CF-1R I I User#-MPl315 User-Ron Moore Title 24 Energy Run-BERNARD I GENERAL INFORMATION Conditioned Floor Area 440 sf Building Type Single Family Detached Construction Type New Building Front Orientation. Front Facing 323 deg (NW) Number of Dwelling Units... 1 Number of Stories 1 Floor Construction Type.... Slab On Grade Glazing Percentage 34 % of floor area Average Glazing U-factor.., 0.57 Btu/hr-sf-F Average Glazing SHGC 0.66 Average Ceiling Height 9.5 ft BUILDING SHELL INSULATION Component Frame Cavity Sheathing Total Assembly Type Type R-value R-value R-value U-factor Location/Comments Wall Wood R-13 R-0 R-13 0.088 R-13 BATT Roof Wood R-ll R-19 R-30 0.031 Vented/R-30BAT Roof Wood R-19 R-0 R-19 0.051 Unvented/R-19 SlabEdge None R-0 R-0 F2=0.720 To Outside FENESTRATION Over- I Area U- Exterior hang/ * Orientation (sf) Factor SHGC Shading Fins Location/Comments Wind Front (NW) 9.0 0.600 0.670 Standard Yes DUAL Vinyl/Wood Door Front (NW) 66.6 0.550 0.650 Standard Yes DUAL Vin./Wd. Dr. Wind Front (NW) 13.5 0.600 0.670 Standard Yes DUAL Vinyl/Wood Wind Back (SE) 12.0 0.600 0.670 Standard Yes DUAL Vinyl/Wood Door Back (SE) 16.6 0.550 0.650 Standard Yes DUAL Vin./Wd. Dr. Wind Right (SW) 16.0 0.600 0.670 Standard None DUAL Vinyl/Wood Wind Back (S) 8.0 0.600 0.670 Standard None DUAL Vinyl/Wood Wind Right (W) 8.0 0.600 0.670 Standard None DUAL Vinyl/Wood £