HomeMy WebLinkAbout2793 LOKER AVE W; ; CB940130; Permit• B U I L D I N G P E R M I T Permit No: CB940130 Project No: A9400189 Development No: 03/08/94 11:32 Page 1 of 1 1 Job Address: 2793 LOKER AV WEST Suite: Permit Type: INDUSTRIAL TENANT IMPROVEMENT Parcel No: 209-081-15-00 Lot#: Valuation: 25,770 Construction Type: VN Occupancy Group: B2 Reference#: Status: ISSUED 02/04/94 03/08/94 DC 'Description: REMODEL EXISTING OFFICE Applied: Appl/Ownr: CHARTER GOLF, INC. 2791 LOKER AV WEST CARLSBAD, CA 92008 *** Fees Required Fees: Adjustments: Total Fees: Fee description Building Permit Plan Check Strong Motion Fee * BUILDING TOTAL Enter "Y" for Plumbi Each Plumbing fixture Each Install/Repair W * PLUMBING TOTAL Enter "Y" for Electric Remodel/Alter Per AMP * ELECTRICAL TOTAL Enter 'Y' for Mechanical Issu Install Furn/Ducts/Heat Pumps Each Exhaust Fan * MECHANICAL TOTAL 619 > 1 Apr/Issue: Entered By: 438-6610 .oo 168.00 364.00 *** Ext fee Data 9.00 6.50 259.00 168.00 5.00 432.00 20.00 Y 7.00 7.00 34.00 10.00 Y 25.00 35.00 15.00 Y 9.00 6.50 31.00 EXPIRED PERMIT PERMIT HAS EXPlRED IN ACCORDANCE WITH U.8.C SECTION 303 {d) OATE----SIGNATURE------ CITY OF CARLSBAD 2075 Las Palmas Dr., Carlsbad, CA 92()()1) (619) 438-1161 r-.v~ tL\3 L\ ~ ~IJCATION PIAN CHECK NO. City of Carlsbad Building Departllll!l'lt 2075 Las Palmas Dr •• carlsbad, CA 92009 (619) 438-1161 a V ESf. VAL _____ ~_~....__, ___ /r-r-;,';.,..0:,,---_ PLAN CK DEPOSIT /6, fr VMJD. BY ,l,<=., __ -,1;._.....-_ __ _ 1. PERMI I l'YPE DATE _____ _.,?~4~'1G"'~--9Jc;..;~::;~- A -0 Commercial O New BuiJdmg ~l'enant Improvement B -D Industrial D New Building D Tenant Improvement C -0 Residential O Apartment O Condo O Single Family Dwelling O Addition/ Alteration 0 Duplex O Demolition O Relocation O Mobile Home O Electrical O Plumbing 0 Mechanical O Pool [] Spa O Retaining Wall [] Solar O Other ____ _ 2. PROJF.Cf INFORMATION FOR OFFICE USE ONLY Address 12-trl5 Loki.it: A-V£... w=-ng or Suite No. r 12 ~L o . . 2., CHECK B£Ww IF SOBMI I 1 fo: D 2 Energy Cales D 2 Structural Cales D 2 Soils Report D I Addressed Envelope PROPOSJID USE CF:'.Ftte SQ. FT. f:r~8 # OF STORIES '2,. 3. WN IAC'I 7 N (If dmerent from applicant) NAME ADDRESS ~"( ~~ UEJJTO \PL.. • iJ:.. 7 So 5. i,1J6p?~Ne .. ~ STATE cA NAME C H-A-.1'Ef2. 6:otR I"'"". ZIPCODE"f21'2 f DAYTELEPHONE 4$2.r 3/ 8 8 ADDREss 27'f/ L~ Ave. We;T cnYCAr2.v;&A,o STATE CA ZIP CODE f:J 200 8 DAY TELEPHONE 4 3 ij , fd/i, / 0 6. CDN'l'RAciuk NAME CITY STATE ADDRESS ZIP CODE DAY TELEPHONE STATE IJC. # IJCENSE CIASS CITY BUSINESS IJC. # oEstGNERNAME ">MliM C.0.t'~~oREss ~Af"\E As Af.()ut..A>Jr CllY ~x~ ZIP CODE DAY TELEPHONE STATE IJC. # c 1 \ 7D I 1. WORkt:RS' WMPENSA:IION Workers' Compensation Deciaratlon: I hereby afhrm that I have a cert1hcate of consent to self-msure issued by the Director of tndustnal Relations, or a certificate of Workers' Compensation Insurance by an admitted insurer, or an exact copy or duplicate thereof certified by the Director of the insurer thereof filed with the Building Inspection Department (Section 3800, Lab. C). INSURANCE COMPANY POIJCY NO. EXPIRATION DATE Ceruhcate of Exemption: I certify that m the performance of the work for which this permit 1s issued, I shall not employ any person many manner so as to become subject to the Workers' Compensation Laws of California. SIGNATURE DATE A. oWNmt-DOIIDER OECl.ARA'fioN bwner-Bmider beclaralion: I hereby afhrm that I am exempt from the Contractor's Llcense Law for the foliowmg reason: D I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale.). [] I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). D I am exempt under Section ________ Business and Professions Code for this reason: (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law (Chapter 9, commencing with Section 7000 of Division 3 of the Business and Professions Code) or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500]). SIGNATURE DATE COMPLETE ruts SECilON FOR NON-RESIDEN'MAL eotIDING PERMITS ONLY: Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? 0 YES ONO Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? DYES D NO Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? 0 YES ONO IF ANY OF TIIEANSWERS ARE YES. A FINAL CERTIFICATE OFOCDJPANCY MAYNOI' BE ISSUED AFTER JULY 1, 1989 UNLESS TIIEAPPUCANT HAS MET OR IS MEETING TIIE RF.QUIREMENTS OF TIIE OFFICE OF EMERGENCY SERVICES AND TIIE AIR POlllTllON CDNTilOL DISIRICT. 9. WNSIRUCIION LENDING AGENCY I hereby afhrm that there 1s a construcuon lendmg agency for the performance of the work for which this permit 1s issued (Sec 3097(1) bvu Code). LENDER'S NAME LENDER'S ADDRESS to. APPIJCANT crut:tiPICA1ioN I certify that I have read the apphcauon and state that the above mtormatlon 1s correct. l agree to comply with all City ordmances and State laws relating to building construction. I hereby authorize representatives of the City of Carlsbad to enter upon the above mentioned property for inspection purposes. I AlSO AGREE 1U SAVE INDEMNIFY AND KEEP HARMLF.<iS TIIE crIY OF CARLSBAD AGAINST AIL UABIIJTIFS. JUDGMENTS, CDSTS AND EXPENSES WIDCH MAY IN ANY WAY .Aa:RUE AGAINST SAID crIY IN CDNSF.QUENCE OF TIIE GRANTING OF TIIlS PERMIT. OSHA: An OSHA permit is required for excavations over 5'0" deep and demolition or construction of structures over 3 stories in height. Expiration. Every permit issued by the Building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 365 days from the date of such permit or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days (Section 30~~:~ni~7;,dq4:e). I WHITE: File YELLOW: Applicant PINK: Finance PERMIT# CB940130 DESCRIPTION: REMODEL EXISTING TYPE: ITI CITY OF CARLSBAD INSPECTION REQUEST FOR 07/21/94 OFFICE INSPECTOR AREA PD PLANCK# CB940130 OCC GRP B2 CONSTR. TYPE VN JOB ADDRESS: 2793 APPLICANT: CHARTER LOKER AV WEST GOLF, INC. STE: LOT: ·coNTRACTOR: OWNER: REMARKS: MW SPECIAL INSTRUCT: TOTAL TIME: --RELATED PERMITS--PERMIT# CB881304 SE910108 AS920053 AS920080 CB921272 SE930008 FA930021 AS930079 TYPE PLUM swow ASTI ASC ITI swow FALARM ASTI ::~::~ 6#J/iil9 438-6~610~ PHONE: < INSPECT ~ ' STATUS EXPIRED ISSUED ISSUED ISSUED ISSUED ISSUED ISSUED ISSUED CD 44 LVL DESCRIPTION ACT COMMENTS ME Rough/Ducts/Dampers 612_ _____ _ -------------------- ---------------------------------------- ***** INSPECTION HISTORY***** DATE 071594 071394 060994 060894 042294 041194 040894 040894 040894 040794 032594 032594 031194 030994 030994 DESCRIPTION Interior Lath/Drywall Frame/Steel/Bolting/Welding Interior Lath/Drywall Frame/Steel/Bolting/Welding Rough Combo Interior Lath/Drywall Interior Lath/Drywall Frame/Steel/Bolting/Welding Rough Electric Frame/Steel/Bolting/Welding Frame/Steel/Bolting/Welding AirCond/Furnace Set Interior Lath/Drywall Frame/Steel/Bolting/Welding Rough Electric ACT AP PA PA PA AP AP AP AP AP AP AP AP AP AP AP INSP PD PD PD PD PD PD PD PD PD PD PD PD PD PD PD COMMENTS CEILING CEILING AT LUNCH ROOM WALLS 12/13/94 INSPECTION HISTORY LISTING FOR PERMIT# CB940130 DATE INSPECTION TYPE INSP ACT COMMENTS 07/21/94 Rough/Ducts/Dampers RI RI MW 07/21/94 Rough/Ducts/Dampers PD co 07/15/94 Interior Lath/Drywall RI RI MW 07/15/94 Interior Lath/Drywall PD AP 07 /13/94 Frame/Steel/Bolting/We! RI RI MW/743-6610 07/13/94 Frame/Steel/Bolting/We! PD PA 06/09/94 Interior Lath/Drywall RI RI BJN/ 06/09/94 Interior Lath/Drywall PD PA 06/08/94 Frame/Steel/Bolting/We! RI RI BJN/CLIFF/438-6610 06/08/94 Frame/Steel/Bolting/We! PD PA 04/22/94 Rough/Ducts/Dampers RI RI MH/743-6610 04/22/94 Rough Combo PD AP CEILING 04/11/94 Interior Lath/Drywall PD AP 04/11/94 Exterior Lath/Drywall RI RI BJN/ 04/08/94 Frame/Steel/Bolting/We! RI RI MH 04/08/94 Frame/Steel/Bolting/We! PD AP 04/08/94 Interior Lath/Drywall PD AP 04/08/94 Exterior Lath/Drywall PD WC 04/08/94 Rough Electric RI RI MH 04/08/94 Rough Electric PD AP 04/07/94 Frame/Steel/Bolting/We! RI RI MH/CLIFF/743-6610 04/07 /94 Frame/Steel/Bolting/Wel PD AP 03/25/94 Frame/Steel/Bolting/Wel RI RI MH/CLIFF/438-6610 03/25/94 Frame/Steel/Bolting/We! PD AP CEILING AT LUNCH ROOM 03/25/94 AirCond/Furnace Set RI RI MH/CLIFF/438-6610 03/25/94 Aircond/Furnace set PD .AP 03/11/94 Interior Lath/Drywall RI RI MH/438-6610 03/11/94 Interior Lath/Drywall PD AP 03/09/94 Frame/Steel/Bolting/Wel RI RI MH/438-6610 03/09/94 Frame/Steel/Bolting/Wel PD AP WALLS 03/09/94 Rough Electric PD AP tJ I~~ J 7 HIT <RETURN> TO CONTINUE ... . . DATE: ESGIL CORPORATION 3 -3 9320 CHESAPEAKE DR., SUITE 208 SAN DIEGO, CA 92123 (619) 560-14-68 JURISDICTION: PLAN CHECK NO: Cf 1/ -/ 3 O SET: _:zz:: CFILE COPY OU?S QD:SSIG~ER C,J;,r S 7" PROJECT ADDRESS:_~.:z-'-~7_9'-"'..;3..__ __ L~o-"-~-<_~_1t.. __ A_.~u ........ u __ _ PROJECT NAME: CHA/? re ;-t a 6 l. r-_ __,;~...;;._-'------------------- D D 0 The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdictio~'s building codes. The plans transmitted herewith will substantially comply with the jurisdic~ion's building codes when minor deficien- cies identified-----------...,...,,--.--are resolved and checked by buil~ing department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewitb is for your information. The plans are being held at Esgil Corp. until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to return to the applicant contact person. o--The applicant·• s-· copy· of the check list has been' sent to:.:. ·· · O Esgil staff did not advise the applicant contact person that plan check has been completed. ~ Esgil staff did advise applicant that the plan check has been completed. Person contacted: /..,t,f.,t.Y kt..oHe4- Date contacted : __ -3 __ -_3....._---'9'-o/'~----Telephone i ~Ac..k -/Al D REMARKS: -------------------------- By,-1&3 E.S(;IL CORPORATION Enclosures: ---------- 0GA Oct-1 OPc r DATE: ESGIL CORPORATION 9320 CHESAPEAKE DR., SUITE 208 SAN DIEGO, CA 92123 (619) 56CH4-68 ::-? _ Q, I JURISDICTION: CARLSBAD --PLAN CHECK NO: SET: k PROJECT ADDRESS: 2 7 7..3 PROJECT NAME: {' J-t A/'?. 7 a~ t. o '< ~ 1-Av u ~~ s 7 Coe..~ D D D - The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficien- cies identified · are resolved and checked by building department staff. . . The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corp. until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the ·_ jurisdiction to return to the app~icant·contact person. Ej The apP,licant's copy c;;f th~-check list has been sent to: LAAA.y /-{1..01-1,::t S 3S.S Ht;?14 So~A<fN 7tJ A .. ~_75'o SA'-J /.J,6~o e,,. 9 2 I z I ________ .;..._ ____ ;....;.... ______________________ ._ ... Iii Esgil staff did not advise the applicant contact person that plan check has been completed. O Esgil staff did advise applicant that the plan check has been completed. Person contacted: L.111, ~ ~..,, i< <-6 ~/4. Date contacted: _________ Telephone # '-/S' ~ -31 BB D REMARKS: _________________________ _ By: d:t.d",J /JdM!.JiL Enclosures: -----------ESGIL CORPORATION UGA [g CM-~PC / PI.AH raECI: NO. :, __ Cj,____,_3/_-""-/..,.3"'-0 ____ _ Date plans received by jurisdiction: JURISDIC'ITOR:__,;CARLSBAD===<------------- Date plans received by Esgil Corporation: 2-? -'7'-1' S ... A A._,~. ; '?"o /i. Jt:-,..,,.o Date w,, r, ,...., ;;; initial plan check completed: 9 ZIZ/ OCCIIPABCY:. ___ __.,<3'-""'------'-2_...__ ____ _ BOll1>ING USE: _______________ _ ffPE OF CX>NS'IRDC'ITOR: ___ :g:c;;;_...aAJ~------- ACl'UAL AREA: ________________ _ ALUJWAm.E AREA: ____________ _ SIORIES: ___ __._V_"'-'-"'-..;..0 _______ _ BEitm: __________________ _ SPRIIOCLERS: ___ ....:.~_(S".;_..~ _____ _ OCCIIPARr LOAD: ______________ _ REMARltS: __________________ _ ... 2..;...--...af3 ___ -_c;;_..;..."T ___ By: Applicant contact person: Tel. Plan check is limited to technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the handicapped. The plan check is based on regulations enforced by the Building Inspection Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department, Fire Department or other departments. Code sections cited are based on the 1991 UBC. The circled· items listed _ need c_larification,_ modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 3O3(c), 1991 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed up the recheck process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, specification, etc. Be sure to enclose the marked up list when you submit the revised plans. LIST NO. 41 CARLSBAD TENANT IMPROVDlENT WITHOUT SPECIFIC ENERGY ZONE DATA OR POLICY SUPPLDIENTS, 1991 UBC / / / I / I· Please make all corrections on the original tracings and submit two new sets of prints, to: Esgil Corporation, 9320 Chesapeake Drive, Suite ~208, San Diego, CA 92123, {619) 560-1468. Please make all corrections on the original tracings and submit two new sets of prints, to: The jurisdiction's building department. Indicate on the Title Sheet of the plans, the name of the legal owner and name of person responsible for the preparation of the plans. Section 302(d). Each sheet of the plans must be signed by the person responsible for their preparation, even though there are no structural changes. Business and Professions Code. Plans and calculations shall be signed by the California state licensed engineer or architect where there are structural changes to existing buildings or structural additions. Please include the California license number, seal, date of license expiration and date plans are signed. Business and Professions Code. Provide the correct address and suite number of tenant space on the plans. Section 302(d). Provide a note on the site plan indicating the previous use of the tenant space or building being remodeled. Section 302. When the character of the occupancy or use changes within a building, the building must be made to comply with current Building Code requirements for the new occupancy. Please provide complete details to show the building with comply. Section 502. --.. .. . -. - UBC Section 304 require!j: the Building Official to determine the .total value of all construction work proposed under this permit. The value shall include -all finish work, painting; roofing, electrical, plumbing, heating, air conditioning, elevator, fire extinguishing systems and any other permanent equipment. Please provide a signed copy of the designer's or contractor's construction cost estimate of all work proposed. Provide a plot plan showing the distance from the building to the property lines and the location of tenant space (or remodel) within the building. 8/1./92 ~- y. ~- y'- 1'· ,11· On the first sheet of the plans indicate: Type of construction of the existing building, present and proposed occupancy classifications of the remodel area a..'!d the occupant lead of the remodel areas and the floor \,;here the tenant improvement is located. Provide a note on the plans indicating if any hazardous materials will be stored and/or used within the building ...,hich exceed the quantities listed in UBC Tables 9-A and 9-B. A complete description of the activities 1md processes that -..,ill occur in this tenant space should be provided. A listing of all hazardous materials should be included. The materials listing should be stated in a fom that would make classification in Tables 9-A and 9-B ;-ossible. The building official may require a technical report to identify and develop methods of protection from hazardous materials. Section 90l(f). If control areas are used for exceeding the exempt amounts of hazardous materials from Tables 9-A and 9-B, they shall be constructed of not less that required for a one-hour occupancy separation. Section 404. The number of control areas within a building used for retail/wholesale stores shall not exceed two; the number of control areas in buildings with other uses shall not exceed four. Footnote l, Tables 9-A and 9-B. The aggregate quantity of any hazardous materials "in use" and "in storage" shall not exceed the quantity listed in Tables 9-A and 9-B for "storage". Footnotes 2 and 3, Tables 9-A and 9-B. Provide a statement on the Title Sheet of the plans that this project shall comply with. Title 24 and 1991 UBC, UMC and UPC and 1990 NEC. Provide a fully dimensioned floor plan showing the size and use of all rooms or areas within the space being improved or altered. Draw the plans to scale and indicate the scale on the plan. Section 302(d). Indicate the use of all spaces adjacent to the area being remodeled or improved. Show any existing fire rated area separation walls, occupancy separation walls, demising walls, shafts or rated corridors. Identify and provide construction details for proposed new fire rated walls. Specify on the plans the fire ratings of assemblies to protect penetrations or proposed openings in existing or new fire walls, floor- ceiling assemblies or roof-ceiling assemblies. /Jo-r 2 ' /iz:) Identify existing walls to be removed, ~ existing walls to recain and proposed new /6- walls. Identify bearing ,.,.alls, non-bearing walls, and shear walls. Show safety glazing in the following locations, per Section 5406(d): a. Where the nearest edge of glazing is within a 24-inch arc of either side of a door in a closed postion (unless there is an intervening wall between the door and the glazing or if the glazing is 5' -0" or higher above the walking surface). b. Glazing greater than 9 square feet with the bottom edge less than 1811 above the floor and the top edge greater than 36" above the floor (unless tJie gla.zing is more than 3611 horizontally away from walking surfaces or if a complying protective bar is installed). c. Glazing in sho,,er and tub enclosures (including windo..,·s within 5 feet of tub or shower floor). Provide a section view of all new interior partitions. Show: (a) {b) (c) (d) Iype, size and spacing of studs. Indicate gauge for metal studs. Specify manufacturer and approval number or indicate "to be ICBO approved". Method of attaching top and bottom plates to structure. {NOIE: Top of partition must be secured to roof or floor framing, unless suspended ceiling has been designed for partition lateral load). Wall sheathing material and details of attachment (size and spacing of fasteners). Show height of partition and suspended ceiling, and height from floor to roof framing or floor framing. Provide notes and/or details to show that the floor and ,.,all finish in toilet rooms are surfaced with a smooth hard non-absorbent material extending five inches up the wall. Similar surfacing shall be provided on the walls from the floor to a height of 4 feet around urinals and within water closet compartments. Section SlO(b). Note on the plans: "All interior finishes must comply with Oiapter 42 of the UBC". Specify "Class ____ flame spread rating· (minimum) for ____________ 11 Note on plan that suspended ceilings shall comply with UBC Iables 47-A and 23-P. In buildings having floors and roofs of wood frame construction, . other than dwelling or hotel occupancies, draft stop the area between the ceiling and floor above so that no concealed space exceeds 1,000 s.f. and no horizontal dimension exceeds 60 L.F. (if space has sprinklers, then 3,000 s.f. and 100 L.F.). Section 2516(£). 7/8/92 / 3/· ~- In buildings having floors and roofs of wood frame construction, other than dwelling or hotel occupancies, draft stop the area between the ceiling and roof above so that no concealed space exceeds 3,000 s.f. and no horizontal dimension exceeds 60 L.F. (if space has sprinklers, then 9,000 s.f. and 100 L.F.). Section 2516(f). Storage areas exceeding 1000 sq. ft. in connection with wholesale or retail sales shall be separated from t..1-ie public area by a one-hour occupancy separation. If the entire building has an automatic sprinkler system, then the occupancy separation need not be provided. Section 702(c). An automatic sprinkler system shall be installed in rooms used by the occupants for the consumption of alcohol and in accessory uses where the total area of such unseparated rooms and assembly uses exceeds 5000 square feet. Section 3802(c). The tenant space and new and/or existing facilities serving the remodeled area must be accessible to and functional for the physically disabled. See the attached correction sheet. Title 24, Part 2. " ''/' ~.-.., p C,.t. "f't$,c_ ~U/1. MIN ,O..'-S Ine width of the required level area on the side into which doors swing shall extend 24 inches past the strike edge for exterior doors and 18 inches past the strike edge for interior doors. Section 2-3304, Title 24. Specify lever-type hardware for passage doors on floors accessible to the disabled. Section 2-3304, Title 24. If both sexes will be employed and the number of employees exceeds four, provide separate toilet facilities for men and women. If "both sexes will be employed and the total number of employees will not exceed four", and only one restroom is provided, note the words in quotation above on the floor plan. Section 705(c). A _.,........,....,... __ -hour occupancy separation is required between. _____ ....,,,,....:occupancy and the _____ occupancy. Table 5-B. Ducts penetrating occupancy or area separation walls must have fire dampers. Section 4306 (j). ~ In areas where the occupant load exceeds __ , two exits are required. See J.,-..:,e;,r .Qoc- Iable 33-A. Provide an exit analysis plan (may be 8 l/2" x 11" or any convenient size). Exits should have a minimum separation of one- half the maximum overall diagonal dimension of the building or area served. Section 3303(c). 3 42. I· The maximum number of required exits and their required separation nn.ist be maintained Wltil egress is provided from the structure. Section 3303{a). Rooms with more than 10 occupants may have£!!.!! exit through£!!.!! adjoining room. Revise exits to comply. Section 3303(e). Exit signs are required whenever two exits are required. Show all required exit sign locations. Section 3314 (a). Show that exits are lighted with at least one foot candle at floor level. Section 3313(a). Show the locations of existing exits from the building and show the path of travel from the remodel area to the existing exits. Note on the plans: "All exits are to be openable from inside without the use of a key or special k.nO\.'ledge". In lieu of the above, in a Group B occupancy, you may note "Provide a sign on or near the exit doors reading I'rlIS DOOR TO REMAIN UNLOCKED DURING BUSINESS HOURS". This signage is only allowed at the~ exit. Section 3304(c). Exit doors should be a minimum size of 3 feet by 6 feet 8 inches with a minimum door swing of 90 degrees. Maximum leaf width is 4 feet. Section 3304(f) • (f ,ct S l I' .-J ~ P • Exit doors should swing in the direction of egress when serving an occupant load of SO or more or when serving any hazardous area. Section 3304(b). Applies to door(s) ___ _ L UAJ e,,-, ~ 00""' . ' Regardless of occupant load, a floor or landing not more than l/2 inch below the threshold is required on each side of an exit door used for disabled access (may be 111 maximum where not used for disabled access). Section 3304(i). Doors should not project more than 7 inches into the required corridor width when fully opened, nor more than one-half of the required. corridor width when in any position. Section 3305(d). Revolving, sliding and overhead -doors are not permitted as exit doors if the occupant load exceeds 9 or the exit door serves a hazardous area. Section 3304(h). ~ Provide panic hardware in Group A,E,H-l,H-2,H-3 \.J and I occupancies. Chapter 33. /· Double acting doors are not allowed when serving a tributary occupant load of more than 100, or when part of a fire assembly, or part of smoke and draft control assemblies or when equipped with panic hardware. Section 3304(b). 5/28/92 fu\ Corridors nn.ist provide continuous protection C:;,J to the exterior of the building. Interruptions by an intervening room is not permitted. Foyers, lobbies or reception rooms constructed as required for corridors are not considered intervening rooms. Section 3305. r-Corridors and exterior exit balconies serving 10 or core occupa."lts must be a minimum 44 inches \.'ide and 7 feet high to the lo;.·est projection. Corridors serving less than 50 occupants may be a minimum of 36 inches in width. Section 3305(b). @ When two exits are required, dead end corridors and exit balconies are limited to 20 feet. Section 3305(e). Corridors serving 30 or more occupants shall have \.'alls and ceilings of one-hour construction. Show compliance or clearly show on plans which of the following exceptions has been satisfied: a. Corridors greater than 30 feet wide when the occupants have an exit independent from the corridor. b. Exterior sides of exterior exit balconies. c. Corridor walls and ceilings need not be of fire-resistive construction within office spaces having an occupant load of 100 or less when the entire story in which the space is located is equipped with an automatic sprinkler system throughout and smoke detectors are installed within the corridor in accordance with their listing. d. Within office spaces occupied by a single tenant, partial height partitions which form corridors and which do not exceed 6 feet in height need not be fire resistive, provided they are constructed in accordance with Section 1705 and are not more than three fourths of the floor- to-ceiling height. Section 3305 (g). _ si Section 330S(g), Exception 5, cannot be used 7-· for non-rated corridors in a fully sprinklered office space if the occupant load in the space exceeds 100. ~ Section 3305(g), Exception 5 does not apply to l7 common corridors where the corridor serves as an exit for non-office areas (manufacturing, warehouse, etc.). /· Section 330S(g), Exception 5 is applicable only for corridors on one floor; the corridors on the lower level(s) must be rated if these lower corridors have openings into them from other levels. 4 • I ··. L./, / If n~n-rated corridors are used per /•/ · 330S(g), Exe. 5, provide a reference corridors on the floor plan, noting: Section to the 1. Corridors are non-rated per Section 3305(g), Exception S. 2. Smoke detectors shall be maxinn.un 30 1 on center. 3. Po...,er supply shall be dedicated branch circuit. Circuit disconnecting means shall be accessible only to authorized personnel and shall be clearly marked FIRE ALAR."! CIRCUIT CONTROL, 1.-ith a lock-on device. G lf a tenant space utilizes Section 3305(g), {J Exception 5, then that· tenant space shall be separated from adjacent ·. spaces by a demising .,.-all constructed as for a· one-hour corridor .,.-all. ~Clearly sho-w ...,here the non-rated corridor lo/ system te:nninates and a rated corridor system comences. t 67. f· One-hour fire-rated corridors shall have interior door openings protected by tight- fitting smoke and draft control assemblies rated 20 minutes, except openings in interior walls of exterior exit balconies. Doors shall be maintained self-closing or be automatic- closing by action of a smoke detector per Section 4306(b). Doors shall be gasketed to provide a smoke and draft seal where the door meets the stop· on sides and top. Section 3305(h). Iotal area of all openings, except doors, in any portion of an interior corridor, shall not exceed 25 percent of the area of the corridor wall of the room which it is separating from the corridor. Such openings shall be protected by fixed glazing listed and labeled for a fire- protection rating of at least 3/4-hour. Section 3305(h). Show rated corridors, lobbies, reception or foyers cross-hatched on the floor plans. Provide a complete architectural section of the corridor, or exterior exit balcony, showing all fire-resistive materials and details of construction for all floors, walls, ce i 1 ing and all penetrations. Section 3305(g). Show the location of fire dampers. Provide fire dampers at duct penetrations of fire- rated occupancy and area separations, shafts and corridor ceilings. Combination fire/smoke dampers are required at duct penetrations of rated corridor walls. Section 4306(j). 8/4/92 .~ If a room with an exhaust fan has a door (_::;,I opening into a rated corridor, show how make- up air ...,ill be provided to the room. The door cannot be undercut, nor can a louver in the door be provided. Section 3305(h)l. ;1.. ;/. /· If building exceeds two stories and has an elevator opening into a rated corridor, show how the smoke and draft control provision of Section 3305(h) will be met. Either provide a separated elevator lobby or a second door at the elevator entry meeting the provision. Section 3305(j). If a second door is provided at the ele,,ator entry, note that it will be readily openable from the car side without a key, tool or special knowledge or effort. Section 5106. New provisions in Chapter 43 of the 1991 UBC require special treatment of penetrations at fire-resistive assemblies. Provide typical details on the plans showing how the fire- resistive integrity will be maintained at the following conditions (Include the manufacturers I names and ICBO numbers (or equal) for any sealant): A. IHROUGH-PENEIRAIIONS (through the entire ·assembly): 1. Fire-resistive bearing walls and/or walls requiring protected openings shall have penetrations protected with through- penetration fire stops having an F- rating, I-rating or complying with UBC Standard 43-1, depending on their locations, sizes and combustibility. 2. Fire resistive floor/ceiling assemblies shall have penetrations protected with through-penetration fire stops having and F-rating, T-rating or complying ~ith UBC Standard 43-1, depending on their sizes, combustibility and whether the penetrations are in walls above. B. MEMBRANE-PENEIRAIIONS (through only one side of an assembly): l. Fire-resistive walls (whether bearing or not and whether requiring fire protected openings or not) shall have penetrations protected with membrane-penetration fire stops having an F-rating or . complying. with UBC Standard 43-1, depending on their size and combustibility. L:ilnited steel electrical outlet boxes . (not exceeding 16 sq. in., nor more than 100 sq. in. for any 100 sq. ft. of wall) require no protection. 2. Fire-resistive ceilings shall have no penetrations, except for noncombustible sprinkler pipes and steel electrical outlet boxes as described above. NOTE: The plans should indicate the various fire-stop ratings required for all penetrations. Provi4e a note on the plans stating "Penetrations of fire-resistive \.alls, floor- ceilings and roof-ceilings shall be protected as required in UBC Sections 4304 and 430511 • f I- Provide evidence of Health Department approval (for restaurants or for tenants using X-ray equipment}. If nonflamcable supply cylinders for medical gas systems are located inside buildings, show how they comply ~ith UBC Section 702(c)4. ELECTRic.AL Sub~it plan sho~ing location of all panels. Wt Tl-! i >J ~ E.IJ......~:LE.::, f¼c :.A Submit panels schedules. Submit electrical load calculations Indicate existing main service size. Indicate existing total rr~in service load. Indicate new additional loads. Indicate wiring cethod, i.e. :E:IT, metal flex. She-.: exit signs en the electrical lighting pla..~(s). As per Section 3313 and 3314 of the 1991 UBC, provide two sources of power to exit signs and exit illumination. Provide receptacle(s} •,.ithin 25' units. UMC Section 509. of H\'AC ~ Provide multiple switch lighting controls per \.:'.;I Title 24, Part 6. Provide mechanical ventilation in all rooms capable of supplying a minimum of 5 cubic feet per minute of outside air with a total circulation of not less than 15 cubic feet per minute per occupant. Section 605 and 705, UBC. Provide mechanical plans showing existing and proposed HVAC equipment, ducts and access to equipment. Detail access and "Working clearances to HVAC equipment. Detail disposal of main condensate drainage from air conditioning-units. (UMC Section 510) Detail overflow (secondary) condensate discharge from air conditioning units that are in a ceiling space. (UMC Section 1205) Fire rated corridors are not to be used to convey air to or from rooms. UMC Section 1002. 6/25/93 0) ~-I /· / Provide gas line plans and calculations, sho.,,ing pipe lengths and gas demands. UPC Section 1219. Provide drain, ,,.-aste and vent plans. Provide ,.,ater line sizing calculations. UPC Section 1009. Detail how floor drain trap seal is to be naintained. UPC Section 707 (floor drain trap priming). Show P & I valve on .,,.-ater heater and detail drain line route from P & I valve to the exterior. UPC Section 1007(e). Show 1/4" per 12" slope on drain and ,.-aste lines. UPC Section 407. ?roYide a drinking fountain at each floor level in assembly occupancies (except drinking a."'ld dining establishments). UBC Section 605. ~ote on the plans that new water closets and associated flushometer ,·alves, if any, shall use no core than 1. 6 gallons per flush and shall meet performance standards established by the American National Standards Institute Standard All2.l9.2, and urinals and associated flushometer valves, if any, shall use no more than one gallon per flush and shall meet performance standards established by the American National Standards Institute Standard All2.l9.2. H & S Code, Section l792l.3(b). ~ C"\oro,.-ide complete energy design calculations, l:7including all existing design and new energy design for this building. See attached non- residential energy design checklist. r· For remodels in an existing conditioned space, sho\ol that the remodeled space will not use more energy than the existing space or show the remodeled space will conform to latest energy design standards. Roof mou."'lted equipment tJUSt be screened and roof penetrations should be minimized (City Policy 80-6). No wiring is permitted on the roof of a building and wiring on the exterior of a building requires approval by the Building Official. (City Policy} 6 f· All roof-mounted equipment shall be concealed from viev. Provide structural detailing for the screening. KISCE[.LIJGIXJS ~ 1 dd" . 1 / 105J P ease see a 1t1ona corrections or remarks \,_./ th.at follov. (1~ To speed up the recheck process, n_ote _on this ::.::.? list (or a copy) .,here each correction item has been addressed, i.e., plan sheet, note or detail nUlllber, calculation page, etc. (167.) Please indicate here if any chariges have been , _ __,/ made to the plans th.at are not a result of corrections from this list. If there are other changes, please briefly describe them and ~here they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please check. ___ Yes ____ .No !he jurisdiction has contracted ...,ith Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 619/560-1468, to perform the plan check for your project. If you have any questions regarding these plan check items, please contact ________ _ C, c. t.r"lJ AhA M tZ/c.. at Esgil Corporation Thank you. Enclosures: l. _______________ _ 2. _______________ _ 3. _______________ _ 6/25/93 HAN~ r-:-A-~u,e..u..J~ A~t.r4 /vor ~ow~ OMJ S#aa-7 ..,,-:- N~~if &.-t.. ~ r.3c. Sac.'1',o•.J 3.~o-"s < (?J Ex,,!> s~"I..'-4'0/" ..t'A S ~ --CH rl "1.t ~ 1,.,,, S 7" o~ 4, cJ' ,4,r 6"4S WA If (.f Ho e.t S<:I) @? e"~,4,t. '-;,-' s;,(04.J /?&t.oC'4-'?U:>? L,, ,_, -r'" h 1' r1.u!d"5 A AJ ,0 (: )'IS ,,.,,.Jy _i,c,,_,,7 ,.e:-,),c.,-'-'~rS ,' ~171"1 A.JU ~tf'4--,-JSu, @ S H0'4.) /?<.Frf)t.tl ~lI,q L),14 .,,, 1 r Co...J.,,~O'-.s rcu« t..,,1-1.,. 6,..,.",e~,. /1cfLOC'44aa Q~ ~ /'\.J '/H~ ,04:y4,r A~tfl4-S. ([j]) S,.-1oc...) ,41A.7of"'1114""?'1c... S,-.,uro,f'~ ~04..1 "1'Ao~s ~,r_ /?t.reoc.,"14'?'t>~ L , c; rl .,,. · 6 x.J' ~ ~ es 17-, '-cf' ~ 't S cf"c.1'rc, -u 131 ld) @ /?Aou1d~ A'a:v,54:~ d"~<r"r.,- L) a~/ ei 4 ;-;, ,,,. ~ t1: ~-u r; t.{ ~ "''-J -· (f:N 1/at.,e,Pd" (NefW IOoo,t )j AAJtf7 . ,4-AJ 't"" C.ff 4-IV ~ er s / ~ L /t:t,., .,., ~ o 1<. Ma e..rl .14 '<.) , C--'4-'-@ ~ ru,•"t ,Ct. er"'?'c.t:':(2 A N lf1 s/ t; "161::) ~v-1. L-r~-1 ;4,_," Hua~-/ /f;-,,er-i s ~"~, /3u /'4"1 tl'1vv,e ~ e, A.J ,r;..ta A 4 ,u~, 7 A. B. DISABLED ACCESS REQUIREl-11':ITTS FOR REMODELS (including alterations, structural repairs, additions, tenant improvements and occupancy changes) GENERAL Full access 1. Path (a) (b) (c) (d) (e) (f) compliance is required for remodels including: of travel to remodeled area. Parking Walks Hazards Curb Ramps Ramps Elevators 2. Primary entrance to remodeled area. (a) Entrances (b) Exit Doors 3. Sanitary facilities serving remodeled area. 4. Drinking fountains and telephones serving remodeled area. REMODELS LESS TIIAN $75,187 When remodels are valued at less than $75,187 access compliance may be limited to the specific area being remodeled when an unreasonable hardship is determined by the enforcing agency. 1. Staff determination of unreasonable hardship shall be made on Form IICA-1, which shall be filed in the project file. 2. When the required work outside of the remodeled area (1.a through l.f above) exceeds 10% of the cost of the work to be done in U10 remodeled area, an unreasonable hardship shall be found to exist (criteria is staff guideline). 3. The unreasonable hardship finding may be by observation when obvious. Form HCA-1 should describe the obvious. c. D. REMODELS $75 1 187 AND IIIGIIER When remodels are valued over $75,187 and specific access requirements cannot be met: 1. The law allows equivalent facilities to be accepted if strict compliance wiU1 the regulations would create an unreasonable hardship. 2. Access cannot be waived unless U1ere are physical or legal barriers that prevent providing either full access compliance or equivalent facilitation compliance. When both access and equivalent facilitation are waived by the enforcement official, ratification is required by an Appeals Board. MULTI-FI.OOR REMODELS: Exceptions and exemptions 1. Provisions for Upper and Lower floors: TI1e Health and Safety Code Section 19955.5 says Uaat, "In privately- funded multi-storied passenger vehicle service stations, shopping centers, offices of physicians and surgeons, and office buildings, subject to this code, floors or levels above and below U1e first floor or ground level are exempt from these requirements if a ramp or elevator is not available to provide public access to such floors or levels." 2. Health and Safety Code Section 19956 says Uaat, "In privately-funded multi-storied buildings, floors or levels above the first floor or ground level are exempt from these requirements if a reasonable portion of all facilities and accoDIJIOdations nonn.-il ly sou1:ht and used by the public in such a building arc accessible lo mid usable by disabled persons." D:\general\disabled.req f;; i,:[: ] ,-~ i'{i ,,:., ~; t ' t: r F ,-n f p f ;; tl TITLE 24 HANDICAPPED ACCESS CORRECTION LIST Jurisdiction ------------------ Plan Check No. ------------ References to section numbers l.'ith prefix "2" are (California Building Code). Prefix "3" is for Part 3 Part 5 (California Plumbing Code). to Title 24, California Code of Regulations, Part 2 (California Electrical Code). Prefix "5" is for Exemptions cla:iJ:led for any item shall be requested in ...,riting and shall include all data needed to determine "unreasonable hardship" as described in Sect.ion 2-422. SITE DEVELOPMENT 1. HAh"DICAPPED PARKING SPACES a. Provide._,... ___ .handicapped spaces. 2-7102(b) b. Space shall be so located that handicapped persons are not compelled to wheel or 'lo/alk behind parked cars other than his/her own. 2-7102(c) c. Parking space shall be a minimum of 9 ft.xl8 ft. with adjacent marked 5 ft. loading zone. Double space shall be 23 ft. 'ldde. Where a single space is provided, the loading/unloading zone shall be on the passenger side of the vehicle. 2-7102(c). d. Maximum slope of parking surface in any direction shall not exceed 1/411 per foot. 2-7102(e). e. Parking space(s) shall be identified with the International Symbol of Accessibility on reflectorized sign affixed to post or wall, and ~ duplicated on parking surface (symbol to be 36"x3611 and painted at the back of the parking stall). 2-7102(£) f. Entrance to parking area ( or at each stall) -~11 have a sign stating that unauthorized vehicle(s) parking in handicapped space(s) may be subject to tow-away. 2-7102(£) g. If covered parking is provided, then a reasonable portion of· the total number of stalls reserved for the disabled shall also be covered. 2-7102(a) h. Entrances to and vertical clearances within accessible levels of parking structures shall be 8 ft. 2 in. to any structural member, duct or pipe. 2-7102(g) 2. CURB RAMPS a. Curb ramps shall pedestrian path 7103(a)) be located wherever crosses curb. (2- b. Curb ramp shall be 4811 min. width (2- 7103{b)) with maximum slope of 1 in 12. 2-7103(d) .. c. A level 48" min. depth landing is required at top of curb ramps over entire curb ramp width. 2·7103{d) d. If no landing is provided, the slope of flared sides shall not exceed l in 12. 2-7103(d) e. Surface is to be slip contra.sting finish side...,alk. 2-7103(f) resistant and a from adjacent f. Border markings shall be 12" "'ide of l/4"xl/411 grooves, 3/411 apart, located at top and sides. 2-7103(h) 3. WALKS a. Site development and grading shall be designed to provide access to primary entrances and access to normal paths of travel and where necessary to provide access shall incorporate pedestrian ramps, curb ramps, etc. 2-710l(a) b. Walks sloping greater than 5% (1 in 20) must comply with ramp requirements of Sec. 2-3307. 2-3325(c) c. ~alk width shall be 4811 minimum, and shall have slip-resistant surfaces. 2-3325(a) d. Dle maximum cross slope shall not exceed 1/411 per foot. 2-3325(a)3 e. Gratings possible. are not 2·332S(b) allowed whenever f. At each gate or door a 60"x6011 level area is required when the gate swings toward the walk. 2-332S(e) g. A 48"x44" deep level area is required when the gate swings away from the walk. 2-3325(e) h. A 2411 clear space is required at strike side of gate or door. 2-332S(e) 4. PEDESTRIAN RAMPS a. A path of travel ~ith a slope greater than l in 20 shall be considered a ramp. 2-3307(a) b. The maximum slope shall be 1 in 12. 2·3307(c.l) c. The width shall be 48" minimum. A minimum width of 60" is required where a ramp serves as a primary entrance to buildings having an occupant load of 300 or more. Group R Occupancies may.be 3611 when the occupant load is ~O or less. 2- 3307(b.l) d. The surface of ramps shall be slip- resistant. 2-3307(g) e. A 60" intermediate landing is required at ma.ximu:n elevation change of 3011 and 7211 landing at each change of direction (over 30 degrees). 2-3307(d.l) f. Landings are required at top and bottom of ramps. 2-3307(d.l) g. Bottom landing shall be i:;inil:n.lm of 72" in the direction of travel. Fig. 2-33- llA h. Top landing shall be 60" x 60" ciini.Izr.J.::1. 2-3307(d.l) i. When· door swings onto top landing, minil:lum depth of landing required is door width plus 4211 • 2-3307(d.l.) j. Top landing shall have 0011 min. width when door swings onto the landing, with 2411 on strike side of door at exterior ramp, or 1811 at interior ramp. 2-3307(d.l) k." Ramp handrails are required on each side of ramp, when slope exceeds l in 15. 2- 3307(e.l) 1. Ramp handrails shall be continuous, located 30"-3411 in height above r.u.ip surface, with 1211 extensions beyond top and bottom, and the ends retw:ned. 2-3307{e.l) m. Handrails shall be l-l/411 to 211 cross section, spaced minimum of l-l/2" from wall. 2-3307(e.l) n. A 211 high curb or wheel guide rail centered 311 ± 111 above ramp surface is . required on both sides where not otherwise bounded by walls when the ramp exceeds 10 feet in length. 2-3307{h.1) 5. SPECIAL ACCESS LIFIS a. Lifts may be provided between levels, in lieu of elevator, when the vertical distance between landings, structural elevator, structural design and safeguards are as allowed by the State of California, Department of Industrial Relations, Division of Occupational Safety and Health. 2-5107(a) . b. 'Die lift platform shall be of sufficient size to accommodate a wheelchair (30"x48"). 2-5107(a) c. 'Dlere shall be a level and clear floor area or landing (60"x60") at each level for access to the lift. 2-5107(a) 6. HAZARDS a. Provide 80" headroom from walkway surface to any overhanging obstruction. 2-3326{b) 7. b. Headroom of maintained for etc. 2-522(f) 8611• minimum shall be walks, corridors, aisles, c. ProtI"l.lding objects ...,ith leading edges bet...,een 27" and 80" above finished floor shall not protrude more tha..'l 4" into walks, corridors, etc. 2-522(f) d. Free standing objects mounted on posts bet...,een 27" and 80" above the floor r.ay project a maximum of 1211 • 2-522(f) e. Abrupt · changes in level exceeding 411 adjacent to walks, except between walY.s and adjacent streets or drives, sh.all be identified by 611 high ..,.arning curbs above ~alk surface. 2-3326(a) ENTRANCES, DOORS, VESIIBULES AND CORRIOORS a. All primary entrances to buildings shall be accessible to tlle handicapped. 2-3301{f) b. All required pass.age doors shall have 32" clear opening at 90 degrees (3611 door~. 2-3304(£) c. At least one of a pair of doors shall meet the minimum 3211 clear entrance width requirement. 2-3304(f) d. Threshold shall be no higher than 1/211 above the floor. Edge to be beveled with a slope no greater than 1 in 2, if more than 1/4". 3304(i.l) e. Exterior level landing may slope up to 1/4" per. foot in any direction for surface drainage. 2-413 f. Door hardware shall be of the lever or push type, mounted 3011 to 4411 above the floor and be operable with· a maximum effort of 8.5 lbs. for exterior doors and S lbs. for interior doors. 2-3304{c), 2· ~304(i.2) g. 'Die lower 1011 of the door shall be of smooth, plane surface (no recess or trap) except at automatic and sliding doors. 2-3304{i.3) h. Building entrance(s) shall be identified by sign with tlle International Symbol of Accessibility. Show location on plan. The symbol shall be a white figure on blue background. 2-522(b) i. At turnstile, provide an access gate, 32" clear width opening, within 30 feet of turnstile. 2-3304(i.4) ~ere shall be a clear area on each side (\.::1/o"i door, 60" deep in direction of door swing and 4411 deep in opposite direction of door swing. 2-3304{i.l) /{Do,,,__ '# / 0 C. I Date, 1/8/ <? f Jurisdiction CARLSBAD Pre}?ared by 1 () t-1%A.J VALUATION AND PLAN CHECK FEE a Bldg. Dept. D Esgil PLAN CHECK NO. 9tt-/3 0 BUILDING ADDRESS ~ 7 q -:3 LOK C;!__ lJ15 .5 7 APPLICANT/CONTACT J. A ,e ,t Y I< '-t>-'-''4-PHONE NO. 'r S' Z -,3 1 S S BUILDING OCCUPANCY A-Z.. DESIGNER PHONE ------TYPE OF CONSTRUCTION l/-..-u CONTRACTOR PHONE ----- 3UILDING PORTION BUILDING AREA VALUATION VALUE MULTIPLIER · i"?e,,.JNCi't c; ct _c., .,.-,....,,,,,,, -rec!J {! 0~ ~ 2577° I I .. Air Conditionin~ Commercial . @ - Residential (a ' Res. or Comm. Fire S"Orinklers @ Total Value I z5, 77t?> Building Perm it fee $ __________________ $.,____. __ ~.;;...::.5...::8:::...!,....:5"=..::..o_· Plan Check re e S $ / G 8 , c> 3 ___;=---------------------=---~~:::...::--==-- c OH Hf: NT S:..: ---------------------------- SHEET __ OF 1'/R7 ... -~ :, PLANNING/ENGINEERING APPROVALS .,, ' PERMIT NUMBER CB 9' Lf" -/3~ DATE __ ,;;f,,"--'t:ff,+-1/2-L-f1<£"-------- ADDREss_ ...... d ____ 7_1_J_L_/l_e,e __ ;J_~_-__ M_· 'f,,_~_r _____ _ RESIDENTIAL RESIDENTIAL ADDITION MINOR ( < $10,000.00) PLAZA CAMINO REAL VILLAGE FAIRE COMPLETE OFFICE BUILDING OTHER~-~~ . µ~r~ PLANNER ------------------DATE _____________ _ ENGINEER -·-Ao.__;~:....=.._...;...;:. =---¥=----,f"~---DATE ~ ff/ C :\ WPS 1 \FILES\BLDG .FRM Rev 11 /15/90 \ N II II II .. .. .. • • • ·~ Q Q Q I t PLANNING OiECKUST Plan Check No. C/4--/ "{JO Address 27'/j lok.Rr f)v-e . Planner DAVID RICK (Name) Phone 438-1161 ext. 4328 ------ APN: JC>f,. O?f i -J< -----~--------------------- Type of Project and Use RefVle>ck. I Offtc.R.. 4---67' Zone ~ Facilities Management Zone 5' CFO (in( t # J crr (It p-r-op ..... e"'""'rty,---,-m,_c_om--,pl.--et·e SPECIAL TAX CALCULATION ~ I .t ~ ~ -N -,:,/. ,:,/. "" "" II II I ~ ; ,:,/. "" II WORKSHEET provided by Building Department.) Legend [2) Item Complete .c: ..c: ..c: u u C.l C i i • ---G. G. G. U2I Item Incomplete -Needs your action 1, 2, 3 Number in circle indicates plancheck number where deficiency was identified Environmental Review Required: YES DATE OF COMPLETION: NO~lYPE __ _ Compliance with conditions of approval? If not, state conditions which require action. Conditions of Approval ______________________ _ i D D Discretionmy Action Required: YES _ NO L lYPE __ _ APPROVAl./RESO. NO. ___ DATE: _____ _ PROJECT NO. ___ _ OTHER RELATED CASES: ____________________ _ Compliance with conditions of approval? If not, state conditions which require action. Conditions of Approval ______________________ _ d D D c.alifomia Coastal C.Omrniwon Permit Required: YES -NO ./ DATE OF APPROVAL: San Diego Coast District, 3111 Camino Del Rio North, Suite 200, San Diego, CA. 92108-1725 (619) 521-8036 Compliance with conditions of approval? If not, state conditions which require action. Conditions of Approval ______________________ _ ~ D D Inclusionary Housing Fee required: YES _ NO _/ (Effective date of Inclusionary Housing Ordinance -May 21, 1993.) rioo CYDD i'oo crbo cloo (rt] D ODD Site Plan: Zoning: 1. 2. 1. 2. 3. 4. Provide a fully dimensioned site plan drawn to scale. Show: North arrow, property lines, easements, existing and proposed structures, streets, existing street improvements, right-of-way width, dimensioned setbacks and existing topographical lines. Provide legal description of property, and assessor's parcel number. Setbacks: Front: Required Shown Int. Side: Required Shown Street Side: Required Shown Rear: Required Shown Lot coverage: Required Shown Height: Required Shown Parking: Spaces Required ';I a'-1 Shown qz_ Guest Spaces Required Shown Additional Comments ________________________ _ OK TO ISSUE AND ENTERED APPROVAL INTO COMPUTER p;; l---.!., DATE z/1jrq 7 PLNCK.FRM City of Carlsbad 94026 Fire Depanment • Bureau of Prevention Plan Review: Requirements Category: Building Plan Check Date of Report: Tuesday, February 15, 1994 Contact Job Name Name Address City, State Charter Golf Job Address 2793 Loker Ave. Larry Kloha 5355 Mira Sorrento Pl Ste 750 San Diego CA 92121 Planning No. ~ Reviewed by:_~=r--+------- Ste. or Bldg. No. ____ _ -.,.. The item you have submitted for review has been approved. The approval is based on plans; information and/or specifications provided in your submittal; therefore any changes to these items after this date, including field modifica- tions, must be reviewed by this office to insure continued conformance with applicable codes. Please review carefully all comments attached, as failure to comply with instructions in this report can result in suspension of permit to construct or install improvements. D Disapproved -Please see the attached report of deficiencies. Please make corrections to plans or specifications necessary to indicate compliance with applicable codes and standards. Submit corrected plans and/or specifications to this office for review. For Fire Department Use Only Review 1st. __ _ 2nd'-----3rd. __ _ Other Agency ID CFD Job# __ 94_0;;,_2_6 __ File# ___ _ 2560 Orion Way • Carlsbad, California 92008 • (619) 931-2121 ~ERTIFICATE ·oF COMP:~IANCE . ,_::.-:: . .' .... · . ···Part 1 ot 3.; ._.: .. :JVU;Cft-1 PROJECT NAME C Ol-F PRINCIPAL DESIGNER· MECHANICAL BUILDING TYPE IZ] PHASE OF CONSTRUCTION D METHOD OF MECHANICAL ~ COMPLIANCE TELEPHONE BUILDING CONDITIONED FLOOR AREA 5 8 NONRESIDENTIAL D HIGH RISE RESIDENTIAL NEW CONSTRUCTION D ADDITION PRESCRIPTIVE D PERFORMANCE DATE z-z ~ - · Building Permit# Checked by/Date Enforcement Agency lm D HOTEL/MOTEL GUEST ROOM 1ZJ_ ALTERATION PROOF OF ENI/ELOPE COMPLIANCE ~ PREVIOUS ENVELOPE PERMIT D ENVELOPE COMPLIANCE ATTACHED This Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations. This certificate applies only to building mechanical requirements. The Principal Mechanical Designer hereby certifies that the proposed building design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other. calculations submitted with this permit application. The proposed building has been designed to meet the mechanical r' -, ,;-1ments containe<: ir. sections 110 through 115, 120 through 124, 140 thro~gh 142, 144 and 145. Please check one: fZ] I hereby affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code to sign this document as the person responsible for its preparation; and that I am a civil engineer, mechanical engineer, or architect. D I affirm that I am eligible under the exemption to Division 3 of the Business and Professions Code by Section 5537 .2 of the Business and Professions Code to sign this document as the person responsible for its preparation; and that I am a licensed contractor preparing documents for work that I have contracted to perform. O I affirm that I am eligible under the exemption to Division 3 of the Business and Professions Code by Section ___ _ of the _______________ Code to sign this document as the person responsible for its preparation; and for the following reason: ___________________________ _ PRINCIPAL MECHANICAL DESIGNER· NAME {tOBEf?.r' sco MECHANICAL MANDATORY MEASURES· ' " · · · · . . • Indicate location on plans of Note Block for Mandatory Measures INSTRUCTIONS TO APPLICANT·, ·· -.·.,,: ·: ·.:1_-.~;,-_: ... ;.: . ,. . ·.:· . ·,<· "-·, :_ .... ,. .. · · · · · '.· .· . · . For detailed instructions on the use of this and all Energy Efficiency Standards compliance forms, please refer to the Nonresidential · ·anual published by the California Energy Commission. NiECH-1: Required on plans for all submittals. Parts 2 & 3 may be incorporated in schedules on plans. MECH-2: Required for all submittals; choose appropriate version depending on method of mechanical compliance. MECH-3 and MECH-4: Required for alt subrnittals. Nonrosid&ntiaJ Comp/ianC6 Form Docember 1991 MECHANICAL.VENTILATION·. ·;,i . . . . . MECH.-4 PROJECT NAME c_ F SYSTEM NAME ,~T' ~ 7: µI:> fl I NOTE: Provide one copy of this fomi for each mechanical system. DATE z-z.s, ( MECHANICALVENTILATION:· '_, -·., ·:,, .J;, .. ,'/:~:::.-_-•.• ..., ··· .. ":,· · .. · • .:· · [E] [I] QJ AREA BASIS OCCUPANCY BASIS REO'D. VAV MINIMUM CFM COND. MIN. NO, MIN. 0.A. DESIGN LARGEST DESIGN SPACE CFM AREA CFM PER SF OF CFM (MAX. OF SUPPLY MIN, MIN. NO. { 2 ? 4 S" (SF) (BXC) PEOPLE JEX 15) DORF) CFM czq1 0.{C::: /t<J /0 150 ISO eoo ~f;., ~~-4 hO /;JO 100() l33. I 200 l4' Z/0 Z/0 l q .s:o 2180 32 '7 zz_ -:s~o 330 l 'JSO /bCj 0 ,v zs1 ' 7 25< zss-I q50 TOTALS (FOR MECH-2) b ] Minimum Ventilation Rate per Section 2-5321, Table~/ -F Based on Expected Number of Occupants or at least 50% of Chapter 33 UBC Occupant Density. Must be greater than or equal to G, or use Transfer Air. CFM CFM . If zone reheat or reoool is used. I must be less than or equal to H X 0.3, or less than or equal to B X 0.4, or less than or equal to 300 CFM. whichever is larger, Must b8 less than or equal to I (it applicable), but no less than G, unless Transfer Air (K) is used. Musi be greater than or equal to (G • H). and, for VAV. greater than or equal to (G -J), AC?~ 014 ,t <50 {00 2(1) 33.0 270 Nonresidential Compliance FOfTTI 09c6mb9f 1991 ; ' -, ' i --- 1 -- I ,, - o: --- I ,I ----- 'I----,~ \ -·-·. ;'\ --~ . ... ----· . I j ~i1::~ r~·-·· I·.-:,~-- I -. -t .. I~- ,f!-. ii?. . _;_ -..... t '"?~:-~ ~n C 'It ',.v· \ • I I . \ I ,. -, , \ I AREA OF TENANT . IMP-ROVEMENT-----. -•·· --... \ .,,_.·. -0 71 . A/•-0 \ r 12'·£1' CLR ~I 14'-6' 12'-,Z,' .. I i:i N'ILL ~ ~ HITM HALL TYFE 'A' -eee LEGEt- -® UJAl-1 - t "' 12'-11!)' Q I j 4&'-11!)' -· I :,:. l i'A/-1,c, I • t.\AitowAi.c ~- YINOING l MACHJND, 1---~ I I Gou..,. L_ ~ rr=--=--=--=--=--=--=- I 11 11 11 11 11 • I I I I I I I I I I I I I I I I I I ------- L _______ _ ~---r---1 -€ B U I L D I N G 07/12/94 10:49 ' Page 1 of 1 Job Address: 2793 LOKER AV WEST Permit Type: PLAN CHECK REVISION Parcel No: 209-081-15-00 1 Valuation: O Construction Type: VN P E R M I T Suite: Lot#: PCR No: PCR94024 Project No: A9400189 Development No: n34 01112194 0001 01 C-PRMT 02 218-00 Occupancy Group: B2 Reference#: 94-130 Status: ISSUED 06/20/94 07/12/94 DC Description: MOVE PARTITION WALLS/LAYOUT Appl/Ownr: PARKER, ANN 9455 RIDGEHAVEN COURT #160 SAN DIEGO, CA 9212 *** Fees Required Fees: Adjustments: Total Fees: Fee description Plan Check Revision 619 Applied: Apr/Issue: Entered By: 268-8998 .00 .00 218.00 *** Ext fee Data 218.00 Fl NAL APPROVAL ~NSP. ___ DATE ___ , CLEARANCE ______ , CITY OF CARLSBAD 2075 Las Palmas Dr., Carlsbad, CA 92009 (619) 438-1161 I I I PERMIT APPUCATION City of carlsbad Building Department 2075 Las Palmas Dr., carlsbad, CA 92009 (619) 438-1161 PIANCHECKNo.rC,C-/3 0 ~ EST. VAL__________ ~ V i. P£ltMl't TIPE PIAN CK DEPOSIT _______ _ VAIID.BY ------------DATE From Llst 1 (see back) give code of Permit-Type: ___________ _ For Residential Projects Only: From Llst 2 (see back) give Code of Structure-Type: ____________________ _ Net Loss/Gain of Dwelling Units _________________ _ 2. PROJF.C'f INFORMATION rl!lla ,.u!!::::v . .,,.,. ::,or.· ·~· '-ciLe12. Nearest Cr Street FOR OFFICE USE ONLY Bmlding or Suite No . Dt:2tVE. ~ 0AO, cA LEGAL DESCRIPTION Lot No. Subd1V1s1on Name/Number Omt No. Phase No. cA£cR BEillW IF sOBMil'IEb: CJ 2 Energy Cales a 2 Structural Cales a 2 Soils Report CJ 1 Addressed Envelope CITI STATE ZIP CODE DAY TELEPHONE s. PROPERTI oWNER NAME (last name first) ADDRESS CITI STATE ZIP CODE DAY TELEPHONE 6. CDNTRACl'oll NAME (last name first) ADDRESS CITI STATE STATE UC.# ZIP CODE IJCENSE CIASS DAY TELEPHONE CITI BUSINESS LIC. # DESIGNER NAME (last name hrst) ADDREss CITI STATE ZIP CODE DAY TELEPHONE STATE LIC. # 1. WoRl<Elts' CDMPENSA'iioN Workers' Compensation Declarat1on: I hereby affirm that I have a ceruficate of consent to self-insure issued by the D1rector of Industnal Relations, or a certificate of Workers' Compensation Insurance by an admitted insurer, or an exact copy or duplicate thereof certified by the Director of the insurer thereof filed with the Building Inspection Department (Section 3800, Lab. C). INSURANCE COMPANY POLICY NO. EXPIRATION DATE Ceruficate of Exemption: I certify that in the performance of the work for wfoch tfos permit 1s issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. SIGNATURE DATE A. oWN£lt-DOiIDER bECI..AltA1iON Owner-Builder Declaration: I hereby amrm ffiat I am exempt from the Contractor's license Law for ffie following reason: CJ I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale.). CJ I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). [J I am exempt under Section _______ Business and Professions Code for this reason: (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law (Chapter 9, commencing with Section 7000 of Division 3 of the Business and Professions Code) or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500]). SIGNATIJRE DATE COMPLETE IBIS SEc'i1oN FOR NON-RESIDENTIAL sOIIDING PERMITS ONLY: Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? DYES CJ NO Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? DYES [J NO Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? DYES [J NO IF ANY OF nm ANSWERS ARE YFS, A FINAL CERTIFICATE OF OCilJPANCY MAY NOT BE~ AFTER JULY 1, 1989 ~ nm APPIJCANT HAS MET OR IS MEETING nm REQUIREMENTS OF nm omCE OF EMERGENCY SERVICES AND nm AIR POU.lJTION OON1ROL DISilUCT. 9. WNSlkUCfioN l.£NDING AGENCY I hereby affirm that there is a construction lendmg agency for the performance of the work for wfoch ffiis permit 1s issued (sec 3097(1) C1VJI Code). LENDER'S NAME LENDER'S ADDRESS to. APPUCAN I CERIIFICA:IIDN I certify that I have read ffie apphcat1on and state that the above mformat1on 1s correct. I agree to comply with all City ordinances and State laws relating to building construction. I hereby authorize representatives of the City of Carlsbad to enter upon the above mentioned property for inspection purposes. I AISO AGREE 'IO SAVE INDEMNIFY AND KEEP HARMLFSS nm crIY OF CARISBAD AGAINST AIL IJAB~ JUDGMENTS, CDSTS AND EXPENSES WlllCH MAY IN ANY WAY ACCRUE AGAINST SAID crIY IN OONSF.QUENCE OF nm GRANTING OF TIIIS PERMIT. OSHA: An OSHA permit is required for excavations over 5'0" deep and demolition or construction of structures over 3 stories in height. Expiration. Every permit issued by the Building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such it is not commenced within 365 days from the date of such permit or if the building or work authorized by Sl.lch permit is suspended or aband t any time er e work is commenced for a period of 180 days (Section 303(d) Uniform Building Code). APPLICANT'S SIGNATURE DATE: 0 . . DATE: ESGIL CORPORATION 7-7 9320 CHESA_PBAKB DR., SUITE 208 SAN DIEGO, CA 92123 (619) 560-1468 JURISDICTION: QAPPLICANT ~JURISDICTION D PLAN CHECKER OFILE COPY OUPS ODESIGNER PLAN CHECK NO: tf~~l 3 O IPcv SET: PROJECT ADDRESS: :Z. 7 '? .3 L. tJ k.. ~ llf... A var t..Jas., PROJECT NAME : __ .;:C.::;...:...1-1=---A-_i<_r_~_-'C. ___ G;;;;;ai...;o ___ '-_':=----r_--=I:;;;_._ D The plans transmitted herewith have been corrected where necessary and substantially comply with the .jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdic"':ipn's building codes when minor deficien- cies identified-,---=---------,,-------are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. 0 The check list transmitted herewitb is for your information. The plans are being held at Esgil Corp. until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to return to the applicant contact person. O The applicant's copy of the check list has been sent to: O Esgil staff did not advise the applicant contact person that plan check has been completed. ~ Esgil staff did advise applicant that tbe plan check has been completed. Person contacted: ~AJ~ .,-.OA-"'l<4'S,. Date contacted: . ?-7-9r,t Telephone i ~All.I<::.-/,v f'fJ REMARKS : /4,v t1 C ;us 7,,.,.., 17 CI y y g/;:JARov1.::-KJ Pc Au , By:· (1., qlf.) Aa&~ e,I;::_ Enclosures: ESGIL CORPORATION -------------- 0GA OcM 0PC DATE: ESGIL CORPORATION 9320 CHESAPEAKE DR., SUITE 208 SAN DIEGO, CA 92123 (619) 560-1468 ~ -28-9'1 JURISDICTION: LJ APPLICANT .JURISDICTION D PLAN CHECKER QFILE COPY QUPS ODESIGNER PLAN CHECK NO: 9t.t-/ 30 /?cZt.J I SET: :r PROJECT ADDRESS: .<? 9 3 L._ 0l(C <. Avu C-c.) e:r ~ r PROJECT NAME: (; H A-r?. 7' cI I< Co1.r-rr D D D D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdic~ion's building codes when minor deficien- cies identified _____________ are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corp. until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to return to the applicant contact person. ~ The applicant's copy of the check list has been sent to: &~Kf.E~ , AN~ 9 'IS S /<tJOc. r.: µAt/trll.) C'-r. #/~CJ D ) 7Z/Z. 3 Esgil staff did not advise the applicant contact person that plan check has been completed. ~ Esgil staff did advise applicant that the plan check has been completed. Person contacted: Al\,.) A...J PA" ,t .c; 11.. Date contacted: 1 b,_g __ __..,,..,g*'-1=, =L..---- ~ REMARKS: 4 e, 4,q~~ 't' /{t. OH14 /I= 2$0 SAAJ t:>~ c.z (; o } Telephone # ~ (p 8 -S 9 '7 8 dGJ}---630 3 $35$ H,te4 Sa,?1t ~~.,.o A (:.A 9 21 Z-/ By: ~,_<.e,0 //oA-,t£te_ Enclosures: -----------ESGIL CORPORATION ~GA DCM 0PC JURISDICTION: (;4-~t. SA$ 4#'0 Date plans received by plan checker: <::,/-:zt /9"'9 PLAN CHECK NO.: 9'.'(-/30 l<ctv Date plan recheck completed: ~-284-tay: C1-e.r-o /-11(:JJ,4-,.::,t_ PROJECT ADDRESS: ;? 7 9 3 J... 0 I<. c.! ;( A cJ ,J e,._) a-!So -r TO: AAJN -~A"f,t C[,t, •' q rs-:r ~' ..-0<; st '-114-t/~'V e.,. '#" /Go RECHECK PLAN CORRECTION SHEET FOREWORD: PLEASE READ Plan check is limited to technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and disabled access. The plan check is based on regulations enforced by the Building Inspection Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department or other departments. The items shown below need clarification, modification or change. All items have to be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 3O3(c), of the Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. A. 0 Please make all corrections on the original tracings and submit two new sets of prints, and any original plan sets that may have been returned to yoy by the jurisdiction, to: /ES.(; IL k(J,1,'(J, 9320 cH~sA-!Ce~'<er ·a" ~ Ze>B / The following items have not been resolved from previous plan reviews. The original correction number has been given for your reference. In case you did not keep a copy of the prior correction list, we have enclosed those pages containing the still outstanding corrections. Please contact me if you have any questions regarding these items. O,i.!Cc> {:.,4 tf 'Z I Z.3 0 Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located on the plans. (D To facilitate rechecking, please identify, next to each item, the sheet of the plans upon which each correction on this sheet has been made and return this check sheet with the revised plans. A t.c.. {i) C<-CArl.'-~ SMo....J IJA 'f"t. I"?' d~ c(A LI~,-, -r / ,\)..., ,$4c..r,o#J 13 I (CJ Have changes been made to the plans not resulting from this correction list? Please check. _____ Yes _______ No 8 /J~oi.J1;a. ~v,~t.C'° /--1,zc,-.-f'~ ) t£',c.r.e-r14, A(.. P"A-rJs .S,c:.~~"""' 4r' /w1t$t!l-'fl4..u1a'4e.. £,o,;,..uc.fa:cc A~i-, Form No. RPCS.4129O JORISDICIIOR:. _ __;;;;~..;...;.-~_c.._S___.,<'.3,_14_~ _____ _ nm:: ~ -z. 8 -9 y, f§ GLEN ADAKEK PLAR QIECICER: D PLAR ama: IDIBER:_.....:9_'-f_-_l_3_o __ ~_~_v __ .Z- D---- (qJ '°~~1/1 ~~ -r-t.AJ" I" 0 __, ,()1.. (.:f"'f' ,£" A/eSc.J1Str1t:1 /,)_" 4,v ~ .s,,c.-,' 0 r.. l / 'L) C.. /.J.1.rc.. l,.v On/<. /AA.) IOI£ IO 7urf /44,u C. ,_,, cI ,,. I<: 11~ 9 L/-/3D ' '"/Met' Ar.:J,u A'u l//<:.10 ~ ~ .s '-IOc.,..> lt,AJ 0 Wo~,~ /AJ A,,tr'4 s /H,4-r A;?~ /(..Jd'""~ .,,,p O O ,._., S u A.) ,,Or.CIC. /~/',; ~~K.Ml .,-~C::. cZA.SC" C! 0 --, ,,o '-(.(" 7 c.C / AL) Oc.> '/~ ci /!-)1... 41U S S HO (c.) I ..t.J c; -r'"Ho '1o r'~t-C:. C!.. D ,::I &£ OF ~Olt. I< ~ #'{_ -r*' µ1;;, ~t..:?""n evr, 7', A /) "_.. ~i. ~ ?a- ,L?t.. '4v Crlc~1e ,~,,(..(._. Ac.e ,CJc,A,J if WHc.Gl'J AA ... J ,; A/(_ t£ l1t..~-4rl, r~ YD C,(._ ti ;4-t.l (£ /J,u,.,J (') t.A. c$ S 7 r O "U S A ,1_ " I,{ ..,. -,-fa-I I' "--,L)'-~"'-J {!_ t-f er,(!_ ,e .,.,q_~;tJSC {!-4-t-l.- (? '-,r--.. _} /-l/J,4,,-.,,,~1::- r bate: 0-27-9'1' Prepared~: Jurisdiction: 0 Bldg. Dept. D Esgil {/1. C[y ,/d.rl_,4,..,,.,e',t_ VALUATION AND PLAN CHECK FEE PLAN CHECK NO. e/j 9'-/-/30 /?~i.J BUILDING ADDREss ::I 7c; .3 L.. o,-,~~ Ave lc..Jt£s7 APPLICANT /CONTACT A, .. .n) PA~/(t,;V(__ BUILDING OCCUPANCY A:r z. TYPE OF CONSTRUCTION VA.) BUILDING PORTION I BUILDING AREA 2Hrt /<cet.1, @ '°.C.~A Air Conditioning Commercial Residential Res. or Comm. Fire Sprinklers Total Value PHONE NO . __ ~_G______,9~-.....,,8:e......,;,_9'....:..9....:;g;,___ DESIGNER PHONE _______ _ CONTRACTOR PHONE ______ _ I VALUATION : MULTIPLIER I VALUE I 87,15 17'/. 30 , -ao I , lJ (:HtJ'CC;:-t.!'~ .<l'l,87 @ @ @ Building Permit Fee $ ______________ _x.. _____ _ Plan Check Fee $ ________________ __,,S'--~-/_.;.7._,-=8;:...Z'--- COMMENTS: __________________________ _ c:\generel\valuetn.~ht SHEET ___ OF __ 3/94 • •• · City of Carlsbad Fire Department 94026 Bureau of Prevention • Plan Review: Requirements Category: Building Plan Check Date of Report: Friday, July a, 1994 Contact Name Address City, State Larry Kloha Reviewed by: __ pty--t-+-~-· -=---- 5355 Mira Sorrento Pl Ste 750 San Diego CA 92121 Bldg. Dept. No. _9 4_-_1_3_0 ___ _ Planning No. Job Name Charter Golf ----------------- Job Address 2793 Loker Ave. Ste. or Bldg. No. ____ _ igi Approved -The item you have submitted for review has been approved. The approval is based on plans; information and/or specifications provided in your submittal; therefore any changes to these items after this date, including field modifica- tions, must be reviewed by this office to insure continued conformance with applicable codes. Please review carefully all comments attached, as failure to comply with instructions in this report can result in suspension of permit to construct or install improvements. D Disapproved -Please see the attached report of deficiencies. Please make corrections to plans or specifications necessary to indicate compliance with applicable codes and standards. Submit corrected plans and/or specifications to this office for review. For Fire Department Use Only Review 1st. __ _ 2nd. __ _ 3rd __ _ Other Agency ID CFDJob# __ 94_0_2_6 __ File# ___ _ 2560 Orion Way • Carlsbad, California 92008 • (619) 931-2121