HomeMy WebLinkAbout2795 OCEAN ST; ; CB022455; PermitCity of Carlsbad
1635 Faraday Av Carlsbad, CA 92008
11-12-2002 Patio/Deck Permit Permit No: 0B022455
Building Inspection Request Line (760) 602-2725
Job Address: 2795 OCEAN ST CBAD
Permit Type: PATIO Status: ISSUED
Parcel No: 2032350300 Lot #: 0 Applied: 08/23/2002
Valuation: $1,836.00 Construction Type: NEW Entered By: AMA
Reference #: Plan Approved: 11/04/2002
Issued: 11/12/2002
Project Title: BEST WESTERN-REPLACE STAIRS W/ Inspect Area:
144 SF DECK EXTENSION
Applicant: . Owner:
TRAVIS DEAL TOBO INVESTMENTS 0978 i.1/12/02 0002 01 02
2785 ROOSEVELT ST COP
CARLSBAD CA 92008
760 729-2598
Total Fees: $81.14 Total Payments To Date: $0.00 Balance Due: $81.14
81.14
Building Permit
Add'I Building Permit Fee
Plan Check
Add'I Plan Check Fee
Strong Motion Fee
Renewal Fee
Add'I Renewal Fee
Other Building Fee
Additional Fees
TOTAL PERMIT FEES
$36.45
$0.00
$23.69
$0.00
$1.00
$0.00
$0.00
$20.00
$0.00
$81.14
FINAL APPROVAL
Inspector. Date: ________ Clearance:
NOTICE: Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively
referred to as "fees/exactions." You-have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must
follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for
processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack,
review, set aside, void, or annul their imposition.
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity
changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any
fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired.
FOR OFFICE USE ONLY
PERMIT APPLICATION PLAN CHECK NO.f&9 cr55
CITY OF CARLSBAD BUILDING DEPARTMENT
EST. VAL;
1635 Faraday Ave., Carlsbad, CA 92008
Plan Ck Deposit
Validated
Date /9 /o
/A
Address (include Bldg/Suite #) Business Name (at this address)
Legal Description 1 Lot No. Subdivision Name/Number Unit No. Phase No. Total # of units
£OT5 43 14,4S,c4'• 44 -.
Aenr'e Parcel # - Existina Use - . , Proposed Use
7o
Name
(Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its
issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law
thapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code) or that he is exempt therefrom, and the basis for the alleged
exption. Arty piolation pf Section 7031.5 by any applicant for a permit subjects tapplicar)t to a civil penalty o)not more)han five hundred dolIa(4$ 500)).
Name -
Address City State/Zip Telephone V
State License II 77 D fr License Class L? C. 1 City Business License -# _i4i!Zer
Designer Name Address City State/Zip Telephone
State License #
PE I'M
Workers' Compensation Declaration: I hereby affirm under penalty of perjury one of the following declarations:
I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance
of the work for which this permit is issued.
I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is
issued. My worker's compensation insurance carrier and policy number are:
Insurance Company . . .. Policy No. Expiration Date__________________
(THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS 161001 OR LESS)
CERTIFICATE OF EXEMPTION: I certify that in the performance of the work for which this permit is Issued, I shall not employ any person in any manner so as
to become subject to the Workers' Compensation Laws of California.
WARNING: Failur to secure workers' compensation coverage Is unlawful, and shall subject an employer to criminal penalties and. civil fines up to one hundred
thousand dollars $ 0 000). additIon to the coat of compensation, damages as provided for In Section 3706 of the L*or cle, interest and attorney's fees.
SIGNATURE \.. . . . DATE 111!i_/ cxi..
I heieby affirm that I am axe ,d from the Contractor's License Law for the following reason:
I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale
(Sec. 7044, Business and Professions Codi: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does
such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is
sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale).
I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The
Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed
pursuant to the Contractor's License Law). ..
o I am exempt under Section Busiiless and Professions Code for this reason: -
I personally plan to provide the major labor and materials for construction of the proposed property improvement. 0 YES ONO
I (have I have not) signed an application for a building permit for the proposed work.
I have contracted with the following person (firm) to provide the proposed construction (include name / address / phone number / contractors license number):
I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone
number / contractors license number):
S. I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name I address / phone number / type
of work): . .
PROPERTY OWNER SIGNATURE . . DATE
:gmgot
Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention
program under Sections 25505, 25533 or 25534 of the Presley-Tanner HazardoUs Substance Account Act? 0 YES 0 NO
Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? 0 YES 0 NO
Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? 0 YES 0 NO
IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE
REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT.
I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097(i) Civil Code).
LENDER'S NAME LENDER'S ADDRESS_______________________________________________________
wizs my
I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all
City ordinances and State laws relating to building construction. I hereby authorize representatives of the Citi of Carlsbad to enter upon the above mentioned
property- for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES,
JUDGMENTS. COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT.
OSHA: An OSHA permit is required for excavation 0 deep and demolition or construction of structures over 3 stories in height. -
EXPIRATION: Every permit issued by the - I ding icial under the provisions or
nifor
he[ ex by limitation and become null and void if the building or work
authorized by such permiiis not com ced Wi 180 days fro the date of such he d g or ork authorized by such permit is suspended or abandoned
at any time after the work Is corn ced f pen s (Section 106.4.4 g od
PPLICANrSSIGNATURE DATE 22 A-cJ e2-
- • WHITE: File YELLOW: Applicant PINK: Finance
Inspection List
Permit#: CB022455 Type: PATIO BEST WESTERN-REPLACE STAIRS WI
144 SF DECK EXTENSION
Date Inspection Item Inspector Act Comments
02/20/2007 92 Compliance Investigation - RI Send to Code or Just Expire?
02/20/2007 92 Compliance Investigation TP AP finaled w/prev. permit same type work
06/02/2004 19 Final Structural TP CO HANDRAILS
02/18/2004 19 Final Structural TP NR contact person
06/04/2003 19 Final Structural TP CO HANDRAILS, PLANS
02/07/2003 18 Exterior Lath/Drywall TP AP @ STAIRS
•
01/03/2003 13 Shear Panels/HD's TP AP WOOD PLY @ WALL
12/19/2002 14 Frame/Steel/Bolting/Weldin SR AP
12/19/2002 34 Rough Electric SR AP
12/09/2002 11 Ftg/Foundation/Piers SR WC •
12/09/2002 14 Frame/Steel/Bolting/Weldin SR AP FOR FLOOR JOIST AND LEDGER
• ATTACHMENT ONLY
Wednesday, February 21, 2007 Page 1 of 1
'City of Carlsbad Bldg Inspection Request
For: 02/20/2007
Permit# CB022455
Title: BEST WESTERN-REPLACE STAIRS WI
Description: 144 SF DECK EXTENSION
Type: PATIO Sub Type:
Job Address: 2795 OCEAN ST
Suite: Lot 0
Location:
OWNER TOBO INVESTMENTS
Owner: TOBO INVESTMENTS ET AL
Remarks: Send to Code or Just Expire?
Inspector Assignment: TP
Phone-
Inspect:__
Total Time:
CD Description
92 Compliance Investigation
Requested By: CHRISTINE
Entered By: CHRISTINE
Act Comment - i'-i et-'
v1"d
Comments/Notices/Holds
Associated PCRs/CVs Original PC#
Inspection History
Date Description
06/02/2004 19 Final Structural
02/18/2004 19 Final Structural
06/04/2003 19 Final Structural
02/07/2003 18 Exterior Lath/Drywall
01/03/2003 13 Shear Panels/HD's
12/19/2002 14 Frame/Steel/Bolting/Welding
12/19/2002 34 Rough Electric
12/09/2002 11 Ftg/Foundation/Piers
12/09/2002 14 Frame/Steel/Bolting/Welding
Act lnsp Comments
CO TP HANDRAILS
NR TP contact person
CO TP HANDRAILS, PLANS
AP TP @ STAIRS
AP TP WOOD PLY @ WALL
AP SR
AP SR
WC SR
AP SR FOR FLOOR JOIST AND LEDGER ATTACHMENT ONLY
EsGil Corporation
2n fPartners/ip with government for Bui1uing Safety
DATE: 10/31/02 NT
JURISDICTION: City of Carlsbad 0 PLAN REVIEWER
0 FILE
PLAN CHECK NO.: 02-2455 SET: II
PROJECT ADDRESS: 2795 Ocean Street
PROJECT NAME: Beach Terrace Inn Deck Extension
El The plans transmitted herewith have been corrected-where necessary and substantially comply
with the jurisdiction's building codes.
The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff.
El The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
El The check list transmitted herewith is for your information. The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck.
El The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
LI The applicant's copy of the check list has been sent to:
Esgil Corporation staff did not advise the applicant that the plan check has been completed.
El Esgil Corporation staff did advise the applicant that the plan check has been completed.
Person contacted: Telephone #:
Date contacted: (by: ) Fax #:
Mail Telephone Fax In Person
REMARKS: City to field verify that the pa travel from the handicapped parking space to the
remodel area and the bathrooms seM the remodel area comply with all the current disabled
access requirements.
By: David Yao Enclosures:
Esgil Corporation
0 GA D MB EJ 0 PC 10/24 trnsmtl.dot
9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576
I.'
I • EsGil Corporation
In Partnership with government for Bui(iIing Safety
DATE: 9/4/02
JURISDICTION: City of Carlsbad
PLAN CHECK NO.: 02-2455 SET: I
PROJECT ADDRESS: 2795 Ocean Street
PROJECT NAME: Beach Terrace Inn Deck Extension
U JAERLICANT
=-REVIEWER
U FILE
II The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes.
fl The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff.
LI The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
The check list transmitted herewith is for your information. The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck.
The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
The applicant's copy of the check list has been sent to:
Wan Young 840 S. Sierra Solana Beach, CA 92075
LI Esgil Corporation staff did .not advise the applicant. that the plan check has been completed.
Esgil Corporation staff did advise the applicant that the plan check has been completed.
Person contacted: Wan Young 61,H) Telephone #: (858)259-6122
Date contacted: I jCp (o (by: (C, ) Fax #: (858)259-6670
Mail ...—Telephone '-" Fax - In Person
LI REMARKS:
By: David Yao Enclosures:
Esgil Corporation 0 GA 0 MB 0 EJ 0 Pc 8/26 trnsmtl.dot
9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576
City of.Carlsbad 02-2455
9/4/02
4
PLAN REVIEW CORRECTION LIST
COMMERCIAL
PLAN CHECK NO.: 02-2455
OCCUPANCY: R-1
TYPE OF CONSTRUCTION: Ill-N/I
ALLOWABLE FLOOR AREA:?
JURISDICTION: City of Carlsbad
USE: hotel
3. ACTUAL AREA:
STORIES: ?
HEIGHT:
SPRINKLERS?: ?
REMARKS:
DATE PLANS RECEIVED BY
JURISDICTION:
DATE INITIAL PLAN REVIEW
COMPLETED: 9/4/02
FOREWORD (PLEASE READ):
OCCUPANT LOAD:
DATE PLANS RECEIVED BY
ESGIL CORPORATION: 8/26
PLAN REVIEWER: David Yao
This plan review is limited to the technical requirements contained in the Uniform Building Code,
Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws
regulating energy conservation, noise attenuation and access for the disabled. This plan review
is based on regulations enforced by the Building Department. You may have other corrections
based on laws and ordinances enforced by the Planning Department, Engineering Department,
Fire Department or other departments. Clearance from those departments may be required
prior to the issuance of a building permit.
Code sections cited are based on the 1997 UBC.
The following items listed need clarification, modification or change. All items must be satisfied
before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3,
1997 Uniform Building Code, the approval of the plans does not permit the violation of any
state, county or city law.
To speed up the recheck process. please note on this list (or a copy) where each
correction item has been addressed, i.e., plan sheet number, specification section. etc.
Be sure to enclose the marked up list when you submit the revised plans.
City of Carlsbad 02-2455
9/4/02
. GENERAL
Please make all corrections on the original tracings, as requested in the correction
list. Submit three sets of plans for commercial/industrial projects (two sets of plans
for residential projects). For expeditious processing, corrected sets can be
submitted in one of two ways:
1. Deliver all corrected sets of plans and calculations/reports directly to the City of
Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760)
602-2700. The City will route the plans to EsGil Corporation and the Carlsbad
Planning, Engineering and Fire Departments2. Bring one corrected set of plans
and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208,
San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and
calculations/reports directly to the City of Carlsbad Building Department for routing
to their Planning, Engineering and Fire Departments.
NOTE: Plans that are submitted directly to EsGil Corporation only will not be
reviewed by the City Planning, Engineering and Fire Departments until review by
EsGil Corporation is complete.
. PLANS
All sheets of the plans and the first sheet of the calculations are required to be
signed by the California licensed architect or engineer responsible for the plan
preparation. Please include the California license number, seal, date of license
expiration and the date the plans are signed. Business and Professions Code.
Provide a statement on the Title Sheet of the plans that this project shall comply
with the 1998 edition of the California Building Code (Title 24), which adopts the
1997 UBC and the 1996 NEC.
. SITE PLAN
Clearly dimension building setbacks from property lines, street centerlines, and
from all adjacent buildings and structures on the site plan.
Provide a statement on the site plan stating: "All property lines, easements and
buildings, both existing and proposed, are shown on this site plan."
. EXITS
Please show the entire deck level plan to show the stairway is not a required
exit. Is the required exit from the building through the deck than to the stairway?
. ROOFS
Specify on the plans the following information for the roof deck materials, per
Section 106.3.3:
Manufacturer's name.
Product name/number.
City of Carlsbad 02-2455
9/4/02
c) ICBO approval number, or equal.
. MISCELLANEOUS LIFE/SAFETY
7. Guardrails (Section 509.1):
Shall be detailed showing adequacy of connections to resist the horizontal
force prescribed in Table 16-B.
Openings between railings shall be less than 4". The triangular openings
formed by the riser, tread and bottom element of a guardrail at a stair shall
be less than 6".
.. TITLE 24 DISABLED ACCESS
8. Provide notes and details on the plans to show compliance with the enclosed
Disabled Access Review List. Disabled access requirements may be more
restrictive than the UBC.
. STRUCTURAL
9. Specify nail size and spacing for all new roof diaphragms. Indicate required
blocking. Maintain maximum diaphragm dimension ratios. Sections 2315 and
2513.
ADDITIONAL
10. To speed up the review process, note on this list (or a copy) where each
correction item has been addressed, i.e., plan sheet, note or detail number,
calculation page, etc.
11. Please indicate here if any changes have been made to the plans that are not a
result of corrections from this list. If there are other changes, please briefly
describe them and where they are located in the plans.
Have changes .been made to the plans not resulting from this correction list?
Please indicate:
El Yes El No
12. The jurisdiction has contracted with Esgil Corporation located at 9320
ChesapeakeDrive, Suite 208, San Diego, California 92123; telephone number of
858/560-1468, to perform the plan review for your project. If you have any
questions regarding these plan review items, please contact David Yao at Esgil
Corporation. Thank you.
City of Carlsbad 02-2455
9/4/02
DEPARTMENT OF STATE ARCHITECT
TITLE 24 DISABLED. ACCESS REQUIREMENTS
. REMODELS. ADDITIONS AND REPAIRS
When alterations, structural repairs or modifications or additions are made to an
existing building, that building, or portion of the building affected, is required to
comply with all of the requirements for new buildings, per Section 11 3413.2. These
requirements apply as follows:
The area of specific alteration, repair or addjtion must comply as "new"
construction.
A primary entrance to the building and the primary, path of travel to the
altered area, must be shown to comply with all accessibility features.
Existing sanitary facilities that serve the, remodeled area must be shown to
comply with all accessibility features.
Existing drinking fountains (if any) must be shown to comply with all
accessibility features.
Existing public telephones (if any) must be shown to comply with all
accessibility features.
END OF DOCUMENT
City of Carlsbad 02-2455
9/4/02
VALUATION AND PLAN CHECK FEE
JURISDICTION: City of Carlsbad PLAN CHECK NO.: 02-2455
PREPARED BY: David Yao DATE: 9/4/02
BUILDING ADDRESS: 2795 Ocean Street
BUILDING OCCUPANCY: TYPE OF CONSTRUCTION:
BUILDING
PORTION
AREA
(Sq. Ft.)
Valuation
Multiplier
Reg.
Mod.
VALUE ($)
deck per city 1,836
Air Conditioning
Fire Sprinklers
TOTAL VALUE 1,836
-11
Jurisdiction Code Icb IBY Ordinance
Bldg. Permit Fee by Ordinance [j
Plan-Check Fee by Ordinance I
Type of Review: I Complete Review ] Structural Only
0 Other
____________ 0 Repetitive Fee Hourly Hour Repeats *
0
Esgil Plan Review Fee
I $36.451
I $23.691
I $20.41
Comments:
Sheet I of I
macvalue.doc
PLANNING DEPARTMENT
BUILDING PLAN CHECK REVIEW CHECKLIST
'r 01A
Plan Check . CB %q Addressooff q c4.) ~igt
Planner Phone (760) 602-
APN: 0—M op- 126 55W 0040 3
Type of Pr ect & Use: Net Project Density: DU/AC
Zoning: • General Facilities Management Zone:
CFD (in/out) #_Date of participation: Remaining net dev acres:______
Circle One (For non-residential development: Type of land used created by this
permit:______________________________________________
Legend: 0 Item Complete 0 Item Incomplete - Needs your action
Environmental Review Required: YES NO TYPE
DATE OF COMPLETION:
>. .0
d3
C.,
C
0.
Compliance with conditions of approval? If not, state conditions which require action.
Conditions of Approval: __________________________________________
0 Discretionary Action Required: YES _NO TYPE t"!bP_,h1Og
APPROVAL/RESO. NO. DATE
PROJECT NO.
OTHER RELATED CASES:
Compliance with conditions or approval? If not, state conditions which r uire action.
Conditions of Approval:,(/7 _.4,,,f__dq
0 Coastal Zone Assessment/Compliance
4(
Project site located in Coastal Zone? YES NO
CA Coastal Commission Authority? YES_ NO
If California Coastal Commission Authority: Contact them at — 575 Metropolitan Drive, Suite
103, San Diego CA 92108-0,67-2370
Determine status (Coastal Pe r Exempt):
Coastal Permit Determination ompleted? YES NO
If NO, complete Coastal Perm n Form now.
Coastal Permit Determination Log #:
Follow-Up Actions:
Stamp Building Plans as "Exempt" or "Coastal Permit Required" (at minimum Floor Plans).
Complete Coastal Permit Determination Log as needed.
0 0 Inclusionary Housing Fee required: YES NO
(Effective date of inclusionary Housing Ordinance - Ma I, 1993.)
Data Entry Completed? YES - NO
(A/P/Ds, Activity Maintenance, enter C #, toolbar, Screens, Housing Fees, Construct Housing
Y/N, Enter Fee, UPDATE!)
H:\ADMINCOUNTER\BldgPInchkRevChklst Rev 9101
Front: Required Shown
Interior Side: Required Shown
Street Side: Required Shown
Rear: Required Shown
Top of slope: Required Shown
Accessory structure setbacks:
Front: Required Shown
Interior Side: Required Shown
Street Side: Required Shown
Rear: Required Shown
Structure separation: Required Shown
Lot Coverage: Required Shown
Height: Required Shown
1
Parking: Spaces Required Shown
(breakdown by uses for commercial and industrial projects -required)
Residential Guest Spaceequired _____ Shown
Additional Comme
I.
MWO
Site Plan:
'Provide a fully dimensional site plan drawn to scale. Show: North arrow, property lines,
easements, existing and proposed structures, streets, existing street improvements, right-
of-way width, dimensional setbacks and existing topographical lines (including all side and
rear yard slopes). u. Provide legal description of property and assessor's parcel number.
Policy 44 - Neighborhood Architectural Design Guidelines
Applicability: YES NO
Project complies YESNO ... Zoning:
1. Setbacks:
PIP /I
F
I -- -
OK TO SSUE A ___________ ED APPROVAL INTO COMPUTER ,L—'ATE J
H:ADMINCOUNTER\BIdgPInchkRevChkIst
00 L
Rev 9/01
Carlsbad Fire Department 022455
1635 Faraday Ave. Fire Prevention
Carlsbad, CA 92008 (760) 602-4660
Plan Review Requirements Category: Building Plan
Date of Report: 09/04/2002
-
Reviewed by:
. Name: Universal Structure
Address: 840 S. Sierra Avenue
City, State: Solana Beach CA 92075
Plan Checker: Job # 022455
Job Name: Beach Terrace Inn Bldg #:•- CB022455
Job Address: 2795 Ocean Street Ste. or Bldg. No.
, Approved The item you have submitted for review has been approved. The approval is
based on plans, information and / or specifications provided in your submittal;
therefore any changes to these items after this date, including field
modifications, must be reviewed by this office to insure continued conformance
with applicable codes and standards. Please review carefully all comments
attached as failure to comply with instructions in this report can result in
suspension of permit to construct or install improvements.
O Approved The item you have submitted for review has been approved subject to the
Subject to attached conditions. The approval is based on plans, information and/or
specifications provided in your submittal. Please review carefully all comments
attached, as failure to comply with instructions in this report can result in
suspension of permit to construct or install improvements. Please resubmit to
this office the necessary plans and / or specifications required to indicate
compliance with applicable codes and standards.
O Incomplete The item you have submitted for review is incomplete. At this time, this office
cannot adequately conduct a review to determine compliance with the
applicable codes and / or standards. Please review carefully all comments
attached. Please resubmit the necessary plans and / or specifications to this
office for review and approval.
Review 1st 2nd 3rd Other Agency ID
FD Job # 022455 ED File #
Wk
STRUCTURAL CALCULATIONS
For
A Roof Deck Extension
At
Beach Terrace Inn
2775 Ocean St.
TCarlsbidXA92008
Project Designer: Travis Deal
3095 State St., Ste. F
Carlsbad, CA 92008
(760) 729-2598
Project Contractor: Jeff Hensley
Hensley Constructic
(760) 213-4338(M)
Project Engineer: Universal Structures
840 S. Sierra Ave.
Solana Beach, CA 92075
(858) 259-6122, 759-6192(F)
July 31, 2002
\3cae4 Tet-rzce. .
I JTD ).fo. 020e15 I Y
DESIGN CRITERIA
A. Codes & References
1. UBC 1997 Edition
2.. Record Drawings by John P. Landry, Inc., dated March 12, 1980
B. Design Loads:
Roof deck live load: €0 psf.
Wind force: Exposure B, basic wind speed= 70 mph
Seismic force: V=2.5 CaIWfR, Zone 4. Where Ca=0.44, Na=1.0
C. Materials:
Lumber: 2x D.F. #2, 4x D.F.#2 & better or #1 as specified, 6x and 8x D.F. #1-
Manufactured wood joists: TJI or ICBO approved.
Parallam PSL, Fb=2,900 psi, E=2.0.ksi, ICBO #NER 481.
Structural steel shapes & plates: A36.
D. Special inspection: None
aJ Tre I ,V a -otfU I '
project, Ac .
•
!Li 4TwC. ,• .
lI/ p . .
EON. Ra 44
il •• ii ii . . ...II I II II i
.
.
•
ik iuIc
• .•. .
TILI
. o7
G14UT
pLyio i.
"&d oV
2.9
.
. -1
qc 22
"~;.yp. V3oMdd Z. • W :73
-
___-., 4x .&c;). . :
OL- (&O . • •
_____ •
. Al
. . . ., .<. I - ( • ,
aTy
•• I I . .
2 X 1=0 (02))16
- 'I
A4C1 f4 Lcl. i 137•
• .5rA1P WAY (G)
I
•
••
ICE
—It
p)Ov Zci?q- Ar WALL
oEc1'.f') i 1S4LLrJW Tfl-D VICA To MATM
• (
ii •. ii - - r
Y &XI6T4 2O2@ ii..' NEW 5TAII2
P-'P .° Zxtoølb" To
IZ'fl'-t. 5W-i. 'L
I1ISTAL.IJ .JT3-W •
I I -
H-
• c.
Ar4- '' I va
,447: L . . .
• C 7d '45'4I 0
I . .
-
. Z,888c 2
;L)izg6
L
. .
.:. • /s F. I.
4 x: 10.
• .
. . .
IVA
REov xIo-tic,, Rcra FWAW
17E&-C.) .. • • • . • . • . I . ,
..
.,•
TO M ATCH, .'c, . •
. • r • -
-•• -----.• .- . . •• - - - • -
Z7bp,L IV&w4x, .O/- 6xi0 PPE-w -Tb cths PEG-p.
• . . .
. : . •
•
j.. . • : .. .. -. . . - - -
-b