Loading...
HomeMy WebLinkAbout2795 OCEAN ST; ; CB022455; PermitCity of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 11-12-2002 Patio/Deck Permit Permit No: 0B022455 Building Inspection Request Line (760) 602-2725 Job Address: 2795 OCEAN ST CBAD Permit Type: PATIO Status: ISSUED Parcel No: 2032350300 Lot #: 0 Applied: 08/23/2002 Valuation: $1,836.00 Construction Type: NEW Entered By: AMA Reference #: Plan Approved: 11/04/2002 Issued: 11/12/2002 Project Title: BEST WESTERN-REPLACE STAIRS W/ Inspect Area: 144 SF DECK EXTENSION Applicant: . Owner: TRAVIS DEAL TOBO INVESTMENTS 0978 i.1/12/02 0002 01 02 2785 ROOSEVELT ST COP CARLSBAD CA 92008 760 729-2598 Total Fees: $81.14 Total Payments To Date: $0.00 Balance Due: $81.14 81.14 Building Permit Add'I Building Permit Fee Plan Check Add'I Plan Check Fee Strong Motion Fee Renewal Fee Add'I Renewal Fee Other Building Fee Additional Fees TOTAL PERMIT FEES $36.45 $0.00 $23.69 $0.00 $1.00 $0.00 $0.00 $20.00 $0.00 $81.14 FINAL APPROVAL Inspector. Date: ________ Clearance: NOTICE: Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exactions." You-have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired. FOR OFFICE USE ONLY PERMIT APPLICATION PLAN CHECK NO.f&9 cr55 CITY OF CARLSBAD BUILDING DEPARTMENT EST. VAL; 1635 Faraday Ave., Carlsbad, CA 92008 Plan Ck Deposit Validated Date /9 /o /A Address (include Bldg/Suite #) Business Name (at this address) Legal Description 1 Lot No. Subdivision Name/Number Unit No. Phase No. Total # of units £OT5 43 14,4S,c4'• 44 -. Aenr'e Parcel # - Existina Use - . , Proposed Use 7o Name (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law thapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code) or that he is exempt therefrom, and the basis for the alleged exption. Arty piolation pf Section 7031.5 by any applicant for a permit subjects tapplicar)t to a civil penalty o)not more)han five hundred dolIa(4$ 500)). Name - Address City State/Zip Telephone V State License II 77 D fr License Class L? C. 1 City Business License -# _i4i!Zer Designer Name Address City State/Zip Telephone State License # PE I'M Workers' Compensation Declaration: I hereby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My worker's compensation insurance carrier and policy number are: Insurance Company . . .. Policy No. Expiration Date__________________ (THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS 161001 OR LESS) CERTIFICATE OF EXEMPTION: I certify that in the performance of the work for which this permit is Issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. WARNING: Failur to secure workers' compensation coverage Is unlawful, and shall subject an employer to criminal penalties and. civil fines up to one hundred thousand dollars $ 0 000). additIon to the coat of compensation, damages as provided for In Section 3706 of the L*or cle, interest and attorney's fees. SIGNATURE \.. . . . DATE 111!i_/ cxi.. I heieby affirm that I am axe ,d from the Contractor's License Law for the following reason: I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Codi: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). .. o I am exempt under Section Busiiless and Professions Code for this reason: - I personally plan to provide the major labor and materials for construction of the proposed property improvement. 0 YES ONO I (have I have not) signed an application for a building permit for the proposed work. I have contracted with the following person (firm) to provide the proposed construction (include name / address / phone number / contractors license number): I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone number / contractors license number): S. I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name I address / phone number / type of work): . . PROPERTY OWNER SIGNATURE . . DATE :gmgot Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner HazardoUs Substance Account Act? 0 YES 0 NO Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? 0 YES 0 NO Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? 0 YES 0 NO IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097(i) Civil Code). LENDER'S NAME LENDER'S ADDRESS_______________________________________________________ wizs my I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all City ordinances and State laws relating to building construction. I hereby authorize representatives of the Citi of Carlsbad to enter upon the above mentioned property- for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS. COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: An OSHA permit is required for excavation 0 deep and demolition or construction of structures over 3 stories in height. - EXPIRATION: Every permit issued by the - I ding icial under the provisions or nifor he[ ex by limitation and become null and void if the building or work authorized by such permiiis not com ced Wi 180 days fro the date of such he d g or ork authorized by such permit is suspended or abandoned at any time after the work Is corn ced f pen s (Section 106.4.4 g od PPLICANrSSIGNATURE DATE 22 A-cJ e2- - • WHITE: File YELLOW: Applicant PINK: Finance Inspection List Permit#: CB022455 Type: PATIO BEST WESTERN-REPLACE STAIRS WI 144 SF DECK EXTENSION Date Inspection Item Inspector Act Comments 02/20/2007 92 Compliance Investigation - RI Send to Code or Just Expire? 02/20/2007 92 Compliance Investigation TP AP finaled w/prev. permit same type work 06/02/2004 19 Final Structural TP CO HANDRAILS 02/18/2004 19 Final Structural TP NR contact person 06/04/2003 19 Final Structural TP CO HANDRAILS, PLANS 02/07/2003 18 Exterior Lath/Drywall TP AP @ STAIRS • 01/03/2003 13 Shear Panels/HD's TP AP WOOD PLY @ WALL 12/19/2002 14 Frame/Steel/Bolting/Weldin SR AP 12/19/2002 34 Rough Electric SR AP 12/09/2002 11 Ftg/Foundation/Piers SR WC • 12/09/2002 14 Frame/Steel/Bolting/Weldin SR AP FOR FLOOR JOIST AND LEDGER • ATTACHMENT ONLY Wednesday, February 21, 2007 Page 1 of 1 'City of Carlsbad Bldg Inspection Request For: 02/20/2007 Permit# CB022455 Title: BEST WESTERN-REPLACE STAIRS WI Description: 144 SF DECK EXTENSION Type: PATIO Sub Type: Job Address: 2795 OCEAN ST Suite: Lot 0 Location: OWNER TOBO INVESTMENTS Owner: TOBO INVESTMENTS ET AL Remarks: Send to Code or Just Expire? Inspector Assignment: TP Phone- Inspect:__ Total Time: CD Description 92 Compliance Investigation Requested By: CHRISTINE Entered By: CHRISTINE Act Comment - i'-i et-' v1"d Comments/Notices/Holds Associated PCRs/CVs Original PC# Inspection History Date Description 06/02/2004 19 Final Structural 02/18/2004 19 Final Structural 06/04/2003 19 Final Structural 02/07/2003 18 Exterior Lath/Drywall 01/03/2003 13 Shear Panels/HD's 12/19/2002 14 Frame/Steel/Bolting/Welding 12/19/2002 34 Rough Electric 12/09/2002 11 Ftg/Foundation/Piers 12/09/2002 14 Frame/Steel/Bolting/Welding Act lnsp Comments CO TP HANDRAILS NR TP contact person CO TP HANDRAILS, PLANS AP TP @ STAIRS AP TP WOOD PLY @ WALL AP SR AP SR WC SR AP SR FOR FLOOR JOIST AND LEDGER ATTACHMENT ONLY EsGil Corporation 2n fPartners/ip with government for Bui1uing Safety DATE: 10/31/02 NT JURISDICTION: City of Carlsbad 0 PLAN REVIEWER 0 FILE PLAN CHECK NO.: 02-2455 SET: II PROJECT ADDRESS: 2795 Ocean Street PROJECT NAME: Beach Terrace Inn Deck Extension El The plans transmitted herewith have been corrected-where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. El The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. El The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. El The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. LI The applicant's copy of the check list has been sent to: Esgil Corporation staff did not advise the applicant that the plan check has been completed. El Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Telephone #: Date contacted: (by: ) Fax #: Mail Telephone Fax In Person REMARKS: City to field verify that the pa travel from the handicapped parking space to the remodel area and the bathrooms seM the remodel area comply with all the current disabled access requirements. By: David Yao Enclosures: Esgil Corporation 0 GA D MB EJ 0 PC 10/24 trnsmtl.dot 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576 I.' I • EsGil Corporation In Partnership with government for Bui(iIing Safety DATE: 9/4/02 JURISDICTION: City of Carlsbad PLAN CHECK NO.: 02-2455 SET: I PROJECT ADDRESS: 2795 Ocean Street PROJECT NAME: Beach Terrace Inn Deck Extension U JAERLICANT =-REVIEWER U FILE II The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. fl The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. LI The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: Wan Young 840 S. Sierra Solana Beach, CA 92075 LI Esgil Corporation staff did .not advise the applicant. that the plan check has been completed. Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Wan Young 61,H) Telephone #: (858)259-6122 Date contacted: I jCp (o (by: (C, ) Fax #: (858)259-6670 Mail ...—Telephone '-" Fax - In Person LI REMARKS: By: David Yao Enclosures: Esgil Corporation 0 GA 0 MB 0 EJ 0 Pc 8/26 trnsmtl.dot 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576 City of.Carlsbad 02-2455 9/4/02 4 PLAN REVIEW CORRECTION LIST COMMERCIAL PLAN CHECK NO.: 02-2455 OCCUPANCY: R-1 TYPE OF CONSTRUCTION: Ill-N/I ALLOWABLE FLOOR AREA:? JURISDICTION: City of Carlsbad USE: hotel 3. ACTUAL AREA: STORIES: ? HEIGHT: SPRINKLERS?: ? REMARKS: DATE PLANS RECEIVED BY JURISDICTION: DATE INITIAL PLAN REVIEW COMPLETED: 9/4/02 FOREWORD (PLEASE READ): OCCUPANT LOAD: DATE PLANS RECEIVED BY ESGIL CORPORATION: 8/26 PLAN REVIEWER: David Yao This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Code sections cited are based on the 1997 UBC. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed up the recheck process. please note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet number, specification section. etc. Be sure to enclose the marked up list when you submit the revised plans. City of Carlsbad 02-2455 9/4/02 . GENERAL Please make all corrections on the original tracings, as requested in the correction list. Submit three sets of plans for commercial/industrial projects (two sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments2. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. . PLANS All sheets of the plans and the first sheet of the calculations are required to be signed by the California licensed architect or engineer responsible for the plan preparation. Please include the California license number, seal, date of license expiration and the date the plans are signed. Business and Professions Code. Provide a statement on the Title Sheet of the plans that this project shall comply with the 1998 edition of the California Building Code (Title 24), which adopts the 1997 UBC and the 1996 NEC. . SITE PLAN Clearly dimension building setbacks from property lines, street centerlines, and from all adjacent buildings and structures on the site plan. Provide a statement on the site plan stating: "All property lines, easements and buildings, both existing and proposed, are shown on this site plan." . EXITS Please show the entire deck level plan to show the stairway is not a required exit. Is the required exit from the building through the deck than to the stairway? . ROOFS Specify on the plans the following information for the roof deck materials, per Section 106.3.3: Manufacturer's name. Product name/number. City of Carlsbad 02-2455 9/4/02 c) ICBO approval number, or equal. . MISCELLANEOUS LIFE/SAFETY 7. Guardrails (Section 509.1): Shall be detailed showing adequacy of connections to resist the horizontal force prescribed in Table 16-B. Openings between railings shall be less than 4". The triangular openings formed by the riser, tread and bottom element of a guardrail at a stair shall be less than 6". .. TITLE 24 DISABLED ACCESS 8. Provide notes and details on the plans to show compliance with the enclosed Disabled Access Review List. Disabled access requirements may be more restrictive than the UBC. . STRUCTURAL 9. Specify nail size and spacing for all new roof diaphragms. Indicate required blocking. Maintain maximum diaphragm dimension ratios. Sections 2315 and 2513. ADDITIONAL 10. To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. 11. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. Have changes .been made to the plans not resulting from this correction list? Please indicate: El Yes El No 12. The jurisdiction has contracted with Esgil Corporation located at 9320 ChesapeakeDrive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact David Yao at Esgil Corporation. Thank you. City of Carlsbad 02-2455 9/4/02 DEPARTMENT OF STATE ARCHITECT TITLE 24 DISABLED. ACCESS REQUIREMENTS . REMODELS. ADDITIONS AND REPAIRS When alterations, structural repairs or modifications or additions are made to an existing building, that building, or portion of the building affected, is required to comply with all of the requirements for new buildings, per Section 11 3413.2. These requirements apply as follows: The area of specific alteration, repair or addjtion must comply as "new" construction. A primary entrance to the building and the primary, path of travel to the altered area, must be shown to comply with all accessibility features. Existing sanitary facilities that serve the, remodeled area must be shown to comply with all accessibility features. Existing drinking fountains (if any) must be shown to comply with all accessibility features. Existing public telephones (if any) must be shown to comply with all accessibility features. END OF DOCUMENT City of Carlsbad 02-2455 9/4/02 VALUATION AND PLAN CHECK FEE JURISDICTION: City of Carlsbad PLAN CHECK NO.: 02-2455 PREPARED BY: David Yao DATE: 9/4/02 BUILDING ADDRESS: 2795 Ocean Street BUILDING OCCUPANCY: TYPE OF CONSTRUCTION: BUILDING PORTION AREA (Sq. Ft.) Valuation Multiplier Reg. Mod. VALUE ($) deck per city 1,836 Air Conditioning Fire Sprinklers TOTAL VALUE 1,836 -11 Jurisdiction Code Icb IBY Ordinance Bldg. Permit Fee by Ordinance [j Plan-Check Fee by Ordinance I Type of Review: I Complete Review ] Structural Only 0 Other ____________ 0 Repetitive Fee Hourly Hour Repeats * 0 Esgil Plan Review Fee I $36.451 I $23.691 I $20.41 Comments: Sheet I of I macvalue.doc PLANNING DEPARTMENT BUILDING PLAN CHECK REVIEW CHECKLIST 'r 01A Plan Check . CB %q Addressooff q c4.) ~igt Planner Phone (760) 602- APN: 0—M op- 126 55W 0040 3 Type of Pr ect & Use: Net Project Density: DU/AC Zoning: • General Facilities Management Zone: CFD (in/out) #_Date of participation: Remaining net dev acres:______ Circle One (For non-residential development: Type of land used created by this permit:______________________________________________ Legend: 0 Item Complete 0 Item Incomplete - Needs your action Environmental Review Required: YES NO TYPE DATE OF COMPLETION: >. .0 d3 C., C 0. Compliance with conditions of approval? If not, state conditions which require action. Conditions of Approval: __________________________________________ 0 Discretionary Action Required: YES _NO TYPE t"!bP_,h1Og APPROVAL/RESO. NO. DATE PROJECT NO. OTHER RELATED CASES: Compliance with conditions or approval? If not, state conditions which r uire action. Conditions of Approval:,(/7 _.4,,,f__dq 0 Coastal Zone Assessment/Compliance 4( Project site located in Coastal Zone? YES NO CA Coastal Commission Authority? YES_ NO If California Coastal Commission Authority: Contact them at — 575 Metropolitan Drive, Suite 103, San Diego CA 92108-0,67-2370 Determine status (Coastal Pe r Exempt): Coastal Permit Determination ompleted? YES NO If NO, complete Coastal Perm n Form now. Coastal Permit Determination Log #: Follow-Up Actions: Stamp Building Plans as "Exempt" or "Coastal Permit Required" (at minimum Floor Plans). Complete Coastal Permit Determination Log as needed. 0 0 Inclusionary Housing Fee required: YES NO (Effective date of inclusionary Housing Ordinance - Ma I, 1993.) Data Entry Completed? YES - NO (A/P/Ds, Activity Maintenance, enter C #, toolbar, Screens, Housing Fees, Construct Housing Y/N, Enter Fee, UPDATE!) H:\ADMINCOUNTER\BldgPInchkRevChklst Rev 9101 Front: Required Shown Interior Side: Required Shown Street Side: Required Shown Rear: Required Shown Top of slope: Required Shown Accessory structure setbacks: Front: Required Shown Interior Side: Required Shown Street Side: Required Shown Rear: Required Shown Structure separation: Required Shown Lot Coverage: Required Shown Height: Required Shown 1 Parking: Spaces Required Shown (breakdown by uses for commercial and industrial projects -required) Residential Guest Spaceequired _____ Shown Additional Comme I. MWO Site Plan: 'Provide a fully dimensional site plan drawn to scale. Show: North arrow, property lines, easements, existing and proposed structures, streets, existing street improvements, right- of-way width, dimensional setbacks and existing topographical lines (including all side and rear yard slopes). u. Provide legal description of property and assessor's parcel number. Policy 44 - Neighborhood Architectural Design Guidelines Applicability: YES NO Project complies YESNO ... Zoning: 1. Setbacks: PIP /I F I -- - OK TO SSUE A ___________ ED APPROVAL INTO COMPUTER ,L—'ATE J H:ADMINCOUNTER\BIdgPInchkRevChkIst 00 L Rev 9/01 Carlsbad Fire Department 022455 1635 Faraday Ave. Fire Prevention Carlsbad, CA 92008 (760) 602-4660 Plan Review Requirements Category: Building Plan Date of Report: 09/04/2002 - Reviewed by: . Name: Universal Structure Address: 840 S. Sierra Avenue City, State: Solana Beach CA 92075 Plan Checker: Job # 022455 Job Name: Beach Terrace Inn Bldg #:•- CB022455 Job Address: 2795 Ocean Street Ste. or Bldg. No. , Approved The item you have submitted for review has been approved. The approval is based on plans, information and / or specifications provided in your submittal; therefore any changes to these items after this date, including field modifications, must be reviewed by this office to insure continued conformance with applicable codes and standards. Please review carefully all comments attached as failure to comply with instructions in this report can result in suspension of permit to construct or install improvements. O Approved The item you have submitted for review has been approved subject to the Subject to attached conditions. The approval is based on plans, information and/or specifications provided in your submittal. Please review carefully all comments attached, as failure to comply with instructions in this report can result in suspension of permit to construct or install improvements. Please resubmit to this office the necessary plans and / or specifications required to indicate compliance with applicable codes and standards. O Incomplete The item you have submitted for review is incomplete. At this time, this office cannot adequately conduct a review to determine compliance with the applicable codes and / or standards. Please review carefully all comments attached. Please resubmit the necessary plans and / or specifications to this office for review and approval. Review 1st 2nd 3rd Other Agency ID FD Job # 022455 ED File # Wk STRUCTURAL CALCULATIONS For A Roof Deck Extension At Beach Terrace Inn 2775 Ocean St. TCarlsbidXA92008 Project Designer: Travis Deal 3095 State St., Ste. F Carlsbad, CA 92008 (760) 729-2598 Project Contractor: Jeff Hensley Hensley Constructic (760) 213-4338(M) Project Engineer: Universal Structures 840 S. Sierra Ave. Solana Beach, CA 92075 (858) 259-6122, 759-6192(F) July 31, 2002 \3cae4 Tet-rzce. . I JTD ).fo. 020e15 I Y DESIGN CRITERIA A. Codes & References 1. UBC 1997 Edition 2.. Record Drawings by John P. Landry, Inc., dated March 12, 1980 B. Design Loads: Roof deck live load: €0 psf. Wind force: Exposure B, basic wind speed= 70 mph Seismic force: V=2.5 CaIWfR, Zone 4. Where Ca=0.44, Na=1.0 C. Materials: Lumber: 2x D.F. #2, 4x D.F.#2 & better or #1 as specified, 6x and 8x D.F. #1- Manufactured wood joists: TJI or ICBO approved. Parallam PSL, Fb=2,900 psi, E=2.0.ksi, ICBO #NER 481. Structural steel shapes & plates: A36. D. Special inspection: None aJ Tre I ,V a -otfU I ' project, Ac . • !Li 4TwC. ,• . lI/ p . . EON. Ra 44 il •• ii ii . . ...II I II II i . . • ik iuIc • .•. . TILI . o7 G14UT pLyio i. "&d oV 2.9 . . -1 qc 22 "~;.yp. V3oMdd Z. • W :73 - ___-., 4x .&c;). . : OL- (&O . • • _____ • . Al . . . ., .<. I - ( • , aTy •• I I . . 2 X 1=0 (02))16 - 'I A4C1 f4 Lcl. i 137• • .5rA1P WAY (G) I • •• ICE —It p)Ov Zci?q- Ar WALL oEc1'.f') i 1S4LLrJW Tfl-D VICA To MATM • ( ii •. ii - - r Y &XI6T4 2O2@ ii..' NEW 5TAII2 P-'P .° Zxtoølb" To IZ'fl'-t. 5W-i. 'L I1ISTAL.IJ .JT3-W • I I - H- • c. Ar4- '' I va ,447: L . . . • C 7d '45'4I 0 I . . - . Z,888c 2 ;L)izg6 L . . .:. • /s F. I. 4 x: 10. • . . . . IVA REov xIo-tic,, Rcra FWAW 17E&-C.) .. • • • . • . • . I . , .. .,• TO M ATCH, .'c, . • . • r • - -•• -----.• .- . . •• - - - • - Z7bp,L IV&w4x, .O/- 6xi0 PPE-w -Tb cths PEG-p. • . . . . : . • • j.. . • : .. .. -. . . - - - -b