HomeMy WebLinkAbout2805 ROOSEVELT ST; ; 86-30; PermitI hereby affirm that I am licensed under
provisions of Chapter 9 (commencing with
Section 7000) of Division 3 of the Business
and Professions Code, and my license is in
full force and effect,
Lic, No __________________ Class
'I hereby affirm that I am exempt from the Contrac-
tors License Law for the following reason (See, 7031.5 Business and Professions Code: Any City or county which me-'quires a permit to Construct, alter, improve, demolish, or
repair any structure, prior toils issuance also requires the ap-
plicant tsr Such permit to tile a signed statement that he is
licensed pursuant to the provisions 01 the Contractor's - License Law (Chapter 9 commencing with Section 7000 of
Division 301 the Business and Professions Code) or that is ex-
empt therefrom and the basis ten the alleged exemption. Any
violation of Section 7031.5 by an applicant for a permit sub-
jects the applicant to civil penalty 01 not more than tine hun-
dred dollars ($500). . -
C I, as owner 01 the properly, or my employees with wages
as their sole compensation, will do the work, and the struc-
ture is not intended or offered for sale (Soc. 7044. Business
and Professions Code: The Contractors License Law does not apply to an owner of property who builds or improves
thereon and who does such work himself or through his own employees, provided that such improvements are not intend-
0d or olfered for sale. If, however, the building or improve-
ment is sold within one year of completion, the owner-builder
will have the burden of proving that he did not build or im-
prove fur the purpose 01 sale).
I, as owner 01 the properly, am exclusively contracting
with licensed contractors to construct the project (Sec. 7044.
Business and Professions Code: The Contractor's License
Law dons not apply loan owner of properly who builds or im-
proves thur005, and who contracts lot each projects with a contractor(s) license pursuant to the Contractors License Law).
-
O Ass homeowner lam improving my home, and the follow- ing conditions exist:
I. The work is being performed prior to solo.
. 2. I have lined in my home for twelve months
prior to completion 01 this work. 0-
3. I have out claimed this exemption during the last three years.
El lam exempt under Sec. ________________ . B & P.C.
for this reason
0
111CF RAI I PAINT PN AM V L PRFt4t I1APfl APPLICANT TO FILL IN II'FORMATION WITHIN SHADED AREA AND DECLARATIONS.
CARLSBAD BUILDING DEPARTMENT
- APPLICATION & PERMIT' Carlsbad, California 92008-1989 (619) 438-5525
V. ST JOB ADDRESS
.
A D! NEAREST CROSS ST. I DATE OF APPLIC TION 9 E# - VALUATION PERMIT NUMBER
Pt9D
ZONi LO C CONTRACTO S PHONE C ]OCTOR BLOCK ' I0B0l VISION ; fl~SSESSOR
OWNER' AM 73 OWNER
2ob%g( '•c•i' -
.
_______ __________________ __________________ OWNERS PHONE _______ ;7\
J
CONTRACTOR'S ADDRESS LICENSE . PLAN I.D. # -WILDING SO. FOOTAGE
' __ _________________ Dr' 5S'77 OWNER'S MAILING ADDRESS
DESIGNER DESIGNERS PHONE
8yIPTIONOF WORK .
. DESIGNER'S ADDRESS LICENSE NO.
,'I'9B6B86 53
.., 0 \_!.IT •"D 7
- - ' NO - - - - F/P F LR ELEV.
I.
0CC GP
STORIES
YO NO ___
NG SPACE RES UNITS GRADING PERMIT ISSUED I REDEVELOPMENT I I TYPE 0CC LOAD FIRE SPR CENSUS TRACT '713 GP LAND 1,!ARKU USE
I AREA I I CONST
- 0 N 0 V 0 No -
YO N[3 Not Valid Unl s Machine Certified
-
CITY. PLUMBING PERMIT - ISSUE 7 --
QTY. MECHANICAL PERMIT - ISSUE 3 -- SUMMARY/ACCOUNT NUMBER
' — EACH FIXTURE TRAP . . . It? -, INSTALL FURN. DUCTS UP TO 100.000 BTU BUILDING PERMIT - 001-810-00-00-8220
21 EACHBUILDINGSEWER OVER 100,00Q . SIGN PERMIT 001-810-00-00-8221
EACHWATERHEATERAND/OR VENT BOILER/COMPRESSOR UP T0,,M'" PLAN CHECK 001-810-00-00-8806
EACH GAS SYSTEM 1 104 OUTLETS 80 1 LE
R/MPRESSO2$IP
, TOTAL PLUMBING 001-810-00-00-8222 '
EACH GAS SYSTEM 5 OR MO RE METAL FIREPLACE ELECTRICAL - 001-810-00-00-8223 3 —
EACH 1NS1A1.. ALTER, REPAIRWATER PIPE VENT FAN S LEDUCT MECHANICAL 001-810-00-00-8224
EACH VACUUM BREAKER _ MECH AUST -HOOD/DUCTS MOBILEHOME 001-810-00-00-8225
WATER SOFTNER
-
CATION OF EA FURNACE/HEATER MOBILEHOME_PARK_INSP
' EACH ROOF DRAIN (INSIDE) ' - * : SOLAR 001-810-00-00-8226 _____
- TOTAL MECHANICAL -
.
STRONG MOTION 880-519-92-33 70
- TOTAL PLUMBING - FIRE SPRINKLERS 001-810-00-00-8227
PUBLIC FACILITIES FEE 332-810-00-00-8930 QTY. ELECTRICAL PERMIT - ISSUE . QTY. SOLAR -ISSUE
NEW CONST EA AMPSWTIBKR , - ' COLLECTORS - SCHOOL FEE - DISTRICT
1 PH 3 PH ' STORAGE TANKS - Carlsbad
EXIST BLDG EA AMP/SWT/BKR ROCK STORAGE - - Encinitas
1 PH 3 PH . . PUMP - San Dieguilo
REMOOEL:ALTER PER CIRCUIT 2......._ PLAN CHECK FEE - San Marcos -
TEMP POLE 200 AMS
OVER 200 AMPS '. - - I , LICENSE TAX 001-810-00-00-8162
TEMP OCCUPANCY (30 DAYS)
J
- MFF 880-519-92-57
. - - - CREDIT DEPOSIT I 4 \f'-
TOTAL ELECTRICAL T TOTAL, SOLAR
1
TOTAL FEES PAYABLE Zo
I HAVE CAREFULLY EXAMINED THE COMPLETED "APPLICATION AND PERMIT" AND DO HEREBY Expiration. Every permit issued bythe Building Official under the provisions of this * AN OSHA PERMIT IS REQUIRED FOR EXCAVATIONS OVER
CERTIFY UNDER PENALTY OF PERJURY THAT ALL INFORMATION HEREON INCLUDING THE I Code shall expire by limitation and become null and void, It the building or work 5'0- DEEP AND DEMOLITION OR CONSTRUCTION OF I authorized by such permit is not commenced within 180 days from the date of such DECLARATIONS ARE TRUE AND CORRECT AND I FURTHER CERTIFY AND AGREE IF A PERMIT IS I permit, or if ih.'uifding Or work a fhOrized by such- permit is suspended or STRUCTURES OVER 3 STORIES IN HEIGHT
ISSUED: TO COMPLY WITH ALL CITY, COUNTY AND STATE LAWS GOVERNING BUILDING CON' I abandoned )al'n,/Iir'after the won is commenced for a eriod of 180 days
STRUCTION. WHETHER SPECIFIED HEREIN OR NOT. I ALSO AGREE TO SAVE INDEMNIFY AND OWNER CONTRACTOR 0 APPRO VD BY KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES. JUDGMENTS, COSTS AND
WHICH WAY ACCRUE AGAINST SAID CITY IN CONSEOUCNCE OF THE EXPENSES MAY IN ANY
GRANTING OF THIS PERMIT. BY PHONE ('3 ,I
VA
Cl thereby affirm that I have a certificate of consent to
aell.insure. or certificate 01 Workers* Compensation In.
- surance. or a certified copy thereof (Sec. 3800. Labor Code)
POLICY NO.
C COMPANY
Copy is flied with the city
Certified copy is hereby furnished
CERTIFICATE OF EXEMPTION FROM
WORKERS' COMPENSATION INSURANCE
(This section need not be completed lithe permit
is br one hundred dollars (5100) or less)
I certify' 'hat in the performance of the work for which
this permit in innued. I shalt not employ any person in any
manner so auto become subject to the Workers' Compen.
nation Laws of California.
NOTICE TO APPLICANT: II. atler making this Certificate
of Exemption, you should become subject to the Workers'
Compensation provisions of the Labor Code, you must
forthwith comply with such provisions or this permit shall
be deemed revoked, -
r 0 I hereby affirm that there In a construction lending
fall agency for the performance of the work for which this per.
0 mit is issued (Sec. 3097. Civil Cede) z W Lender's Name_________________________________ _J
Lenders Address
FIELD INSPECTION RECORD
REQUIRED SPECIAL INSPECTIONS
REQ IF INSPECTORS INSPECTION CHECKED APPROVAL DATE
SOILS COMPLIANCE
PRIOR TO
FOUNDATION INSP
STRUCTURAL CONCRETE
OVER 2000 PSI
PRESTRESSED
CONCRETE
POST TENSIONED
CONCRETE
FIELD WELDING
HIGH STRENGTH
BOLf S
SPECIAL MASON-
PILES CAISSONS
INSPECTOR'S N
. : -....
k - •" ;. -'
1 !'
H
4,
TYPE i DATE INSPECTOR
BUILDING
FOUNDATION
REINFORCED STEEL
MASONRY
GUN ITE OR GROUT
SUB FRAME 0 FLOOR 0 CEILLING
SHEATHING 0 ROOF 0 S1EAR
FRAME
EXTERIOR LATH
INSULATION
INTERIOR LATH & DRYWALL
PLUMBING
O SEWER AND BL/CO 0 PL/CO
- I -
UNDERGROUND DWASTE Di WATER
TOP OUT DWASTE DVIATER
TUB AND SHOWER PAN
GAS TEST
O WATER HEATER 0 SOLAR WTER
ELECTRICAL
O ELECTRIC UNDERGROUND 0 UFFER
ROUGH ELECTRIC .'
o ELECTRIC SERVICE 0 TEMPORARY
O BONDING 0 POOL
MECHANICAL
O DUCT & PLEM., 0 REF. PIPIJG
HEAT - AIR COND. SYSTEMS
VENTILATING SYSTEMS H.. . -.
CALL FOR FINAL INSPECTION WHEN ALL APPROPRIATE ITEMS ABOVE HAVE BEEN APPROVED
FINAL
PLUMBING
ELECTRICAL
MECHANICAL
GAS
BUILDING
SPECIAL CONDITIONS
FINAL BUILDING INSPECTION
PLAN CHECK NUMBER: 2805 RoOBQVOlt DATE: 4-9-86
PROJECT NAME: Convert hbhk store to tearoom
2805 Roosuv1t
ADDRESS:
PROJECT NO.: UNIT NUMBER: _________________ PHASE NO.:
TYPE OF UNIT: T. 1.NUMBER OF UNITS:
CONTACT PERSON: Peter
CONTACT TELEPHONE: 129-61UG
BY: _______________________ INSPECTED: ____________ APPROVED DISAPPROVED
INSPECTED DATE
INSPECTED DATE
BY: INSPECTED: ____________ APPROVED ______ DISAPPROVED
INSPECTED DATE
BY: ________________________ INSPECTED: ____________ APPROVED. ______ DISAPPROVED
COMMENTS: . . .
Rev. 1186 WHITE: Suspense GREEN: Engineering CANARY: Utilities PINK: Planning Fi
ESGIL CORPORATION
9320 CHESAPEAKE DR.. SUITE 208
SAN I)IEGO, CA 92123
(6W) 560-1468
DATE: 1 i16 DAPPLICANT
JURISDICTION
JURISDICTION: Ciic.L, i3eD PLAN CHECKER
0 FILE COPY
PLAN CHECK NO: DS
0 DESIGNER
PROJECT ADDRESS:
PROJECT NAME:
The plans transmitted herewith have been corrected where
necessary and substantially comply with the jurisdiction's
building codes.
The plans transmitted herewith will substantially comply
with the jurisdiction's building codes when minor deficien-
cies identified are resolved and
checked by building departnient staff.
The plans transmitted herewith have significant deficiencies
identified on. the enclosed check list and should be corrected
and resubmitted for a complete recheck.
The check list transmitted herewith is the jurisdiction's
copy for your information. The plans are being held at un Esgil Corp. until corrected plans are submitted for recheck.
D The applicant's copy of the check list is enclosed for the
jurisdiction to return to the applicant contact person.
The applicant's copy of the check list has been sent to:-
7-9 R L S /.-3 Ct). ?2CCV
Esgil staff did not advise the applicant contact person that
plan check has been completed.
I Esgil staff did advise applicant that the plan check has
been completed. Person contacted:
Date contacted: Telephone #
REMARKS:
BY: 1-1(36 lHii ENCL:_______________ ESGIL CORPORATION
JURISDICTION OF
T0:FEiE1 'O/3'-) ( I APPLICANT COPY
2ROc Cs -47 37 ( I JURISDICTION
C)t,-ip c-J.. ( I PLAN CHECKER COPY
r ' ESGIL FILE COPY
TENANT IMPROVEMENT & INTERIOR ALTERATION CORRECTION SHEET
Plan Check Number 30
Site Address _7C(€t'EL7_Sr
Owner /9 7 ( k10i3 (/
Building Code Applicable 1982tJ.B.C.
Occupant Load Stories____________________
Previous Proposed Proposed Occupancy Occupancy _____Use lEA /2c7'-j
Type of Construction A/Sprinklers: Yes
Allowable Floor Area Actual____________________
Basis for Area Increase_________________________________________
-
J. Remarks
Date Plan Submitted:to Jurisdiction- to Esgil I-?
Date Initial Plan Check Completed (__2-_'C By 14R97 ZX./E1J7
Applicant Contact Person P&T&/CO/Tel. 7Z/'-
FOREWORD: PLEASE READ
I. This plan check is limited to technical requirements contained in the Uniform
Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National
Electrical Code and State laws regulating energy conservation, noise attenuation
and access for the handicapped. The plan check is based on regulations enforced
by the Building Inspection Department.
You may have other corrections based on laws and ordinances enforced by the
Planning Department, Engineering Department or other departments. For
information regarding those departments, please contact those departments.
The items listed below require plan clarification, modification or change.
All items have to be satisfied before the plans will be in conformance with the
cited codes and regulations. Per Section 303(c), 1982 Uniform Building Code,
the approval of the plans does not permit the violation of any State, County
or City law.
() Please submit two sets of corrected plans and enclose a copy of this list with your
notes indicating where corrections were made i.e., sheet, detail, etc ...return corrected
plans and documents ONLY to the locations checked below:
Esgil Corporation at 9320 Chesapeake Dr., Suite 268, San Diego, CA, 92123
Telephone (619) 560-1468
0 Jurisdiction Building Department
-
- 10/22/85
C5) The responsible designer is required to sign
'
each
flgt_of the plans. A State-licensed Architect or
Engineer is required where there are structural
changes to an existing building or a structural
addition. (Business and Professions Code)
V Provide the correct address and suite number of
tenant space on the plans. Section 302
Provide a note on the plan indicating the previous
use of the tenant space or building being remodeled.
Section 302
When the character of the occupancy or use changes
within a building,the building must be made to
comply with current Building Code requirements for
the new occupancy. Please provide complete details
to show the building will comply. Section 502
09 UBC Section 304 requires the Building Official to
determine the total value of all construction work
proposed under this permit. The value shall in-
clude all finish work, painting, roofing, electrical,
plumbing, heating, air conditioning, elevator,
fire extinguishing systems and any other permanent
equipment. Please provide a signed copy of the
designer's or contractor's construction cost
estimate of all work proposed.
Provide a plot plan showing the distances from
the building to the property lines and the
location of tenant space (or remodel) within
the building.
On the first sheet of the plans indicate: Type of
construction of the existing building, present and
proposed occupancy classifications of the remodel
area and the occupant load of the remodel areas
and total building area.
Specify on the plan title sheet the Building Code
Edition used for the design of the proposed work.
Provide a plan showing the size and use of all rooms or ireas within the
space being improved or altered. Draw the plan to
scale and indicate the scale on the plan.
Indicate the use of all spaces adjacent to the
area being remodeled or improved.
Show any existing fire rated area separation
walls, occupancy separation walls, shafts or
rated corridors. Identify and provide con-
struction details for proposed new fire
rated walls.
Specify on the plans the fire ratings of / assemblies to protect proposed openings in
existing or new fire walls.
Identify existing walls to be removed, existing
walls to remain and proposed new walls.
Identify bearing walls, non-bearing walls, and
shear walls.
(3. ceALc.i /o&fTIFI C.A) qo-qa tWOfl.- /c1WS
77-/& L/M'rS OF THE_ ..JOI3 cOL'ee&D tc/JDE' 'i/-H
i7FiLft(tr ,rf'L'cMyIoI\J.
Provide a section view of all new interior
partitions. Show:
Type, size and spacing of studs.
Indicate gauge for metal studs.
Specify manufacturer and approval
number or indicate "to be ICBO
approved".
Method of attaching top and bottom
plates to structure. (NOTE: Top or
partition must be secured to roof
or floor framing, unless suspended
ceiling has been designed for
partition lateral load.)
Wall sheathing material and details
of attachment. (Size and spacing
of fasteners).
Height of partition and suspended
ceiling.
Provide notes and/or details to show that the
floor and wall finish in toilet rooms are
surfaced with a smooth hard non-absorbent material
extending five inches up the wall. Similar
surfacing shall be provided on the walls from
the floor to a height of 4 feet around urinals
and within water closet compartments.
Note on the plan: "All interior finishes
must comply with Chapter 42 of the rJBC".
Specify "class flame spread rating
(minimum) for
Lateral bracing for suspended ceiling must be provided.
(UBC Table 23-J Where ceiling loads are less than 5
PSF and not supporting interior partitions, ceiling
bracing shall be provided by four No. 12 gauge wires
secured to the main runner within 2 inches of the
cross runner intersection and splayed 900 from each
other at an angle not exceeding 45° from the plane
of the ceiling. These horizontal restraint points
shall be placed 12 feet o.c. in both directions with
the first point within 4 feet of each wall. Attach-
ment of restraint wires to the structure above shall
be adequate for the load imposed..
2,2< Draft stop and suspended ceiling in wood frame floor
/ construction every 1,000 sq. ft. and in attics of
combustible construction every 3,000 sq. ft. The
maximum distance allowed between draft stops is 60
feet. Section 2516(f)
The tenant space and new and/or existing facilities
/ serving the remodeled area must be accessible to
and functional for the physically handicapped. See the
attached correction sheet. Title 24, Part 2
Show the exit sign locations; show any required
directional -exit signs. Section 3314
Rooms with more than 10 occupants may have one exit
through one adjoining room. Revise exits to comply.
Section 3303(e)
)i. Two complying exits are required from
Exits must be, and maintain, a distance apart of at
least 1/2 the maximum diagonal dimension of the area
served by the exits. Section 3303
3/ Assembly rooms with more than 50 occupants shall
not have a lock or latch on exit doors unless they
are equipped with panic hardware. Section 3318.
(D8- Note on the plans: "All exits are to be openable
from inside without use of a key or special know-
ledge". Section 3304(c). Or NOTE: "Provide a
sign on or near the exit doors reading: THIS DOOR
TO REMAIN UNLOCKED DURING BUSINESS HOURS", and meet
all other criteria of Section 3304(c) 1.
(2, Required exit doorways shall be not less than 36
inches in width and not less than 6 feet - 8 inches
in height. Section 3304(e)
Exit doors shall swing in the direction of exit
travel (occupant load exceeds 50). Section 3304(b).
3/ Show the locations of existing exits from the build-
ing and show the path of travel from the remodel
area to the existing exits.
corridors must provide continuous protection to the
exterior of the building. Interruptions by inter-
vening room is not permitted. Foyers, lobbies or
reception rooms constructed as required for corridors
are not considered intervening rooms.
DcOiz c3I2E. 7HE Et/Y Pee`),
Show exit corridors as 44 inches wide minimum. Dead-
end corridors are limited to 20 feet when more than
one exit is required from the corridor. Section 3305
Provide one-hour construction details for
( all corridor walls and ceilings serving an
occupant load of 30 or more. Identify all
rated corridors. Walls of reception rooms
and lobbies which are included within pro-
tected corridors must have walls and ceil-
ings constructed as required for corridors.
Protect all interior openings in corridor
walls and ceilings. Door and frame must be
labeled 20-minute smoke and draft control
assembly with self-closers or automatic
closers with smoke detectors. Section
3305(h). Glazing must be 1/4 inch-thick
wired glass installed in steel frames and
cannot exceed 25 percent of the common
wall area. Section 3305(h)2.
Show the location of fire dampers. Provide fire
dampers at duct penetrations of fire-rated occupancy
and area separations, shafts and corridor walls
and ceilings. Section 4306(j)
37X' Provide mechanical ventilation in all rooms capable
( of supplying a minimum of 5 cubic feet per minute
of outside air with a total circulation of not less
than 15 cubic feet per minute per occupant.
Section 605 and 705
3,/ If the tenant improvement area will not have a
/ comfort heating or cooling system consuming more
than 5 BTU per hour per square foot, note on the
plan "Tenant Improvement area is not heated or
cooled more than 5 BTU per hour per square foot and is
exempt from Energy Conservation Regulations".
If the tenant improvement area will have a
comfort heating or cooling system consuming
more than 5 BTU per hour per square foot, note
on the plan "Tenant Improvement must comply with
Energy Conservation Regulations".
If the tenant improvement area must comply with
the energy conservation regulations and the exist-
ing building was originally constructed in com-
pliance with the energy conservation regulations,
provide two copies of the original Energy Com-
pliance Documentation forms.
If the tenant improvement area must comply with
the Energy Conservation Regulations and the exist-
ing building was not originally constructed in
compliance with the Energy Conservation Regulations,
address the appropriate items that will follow.
If HVAC is to be installed, provide two sets of
energy conservation compliance forms 1, 2, 3, 4,
and 6. Title 24 Section 2-5312.
If HVAC is to be installed, provide two sets of
HVAC plans. Title 24 Section 2-5306.
41. If lighting is to be installed, provide two sets
of energy conservation compliance form 5.
Title 24 Sections 2-5343 & 2-5344.
If HVAC is to be installed, incorporate in the
plans or specifications, the attached "Title
24 Mandatory Requirements".
If HVAC is to be installed, the required energy
documentation required to show compliance with the
energy conservation requirements, is required
to be signed by the California licensed person
responsible for its preparation. Title 20
Section 1403(a)l.
If HVAC is to be installed, recent charges in the
regulations required specific signed construction
compliance statements be filed with the Building
Department prior to use or occupancy of the im-
proved area. Incorporate in the plans or
specifications the attached "Title 24-Construction
Compliance Statement Requirements".
41 Structural design calculations are required to
show code compliance if any of the following
conditions exist. Section 302(b):
Alteration of existing vertical or horizontal
load carrying structure.
Increase in live or dead loads on floors or
roof.
Other______________________________________
ELECTRICAL
48. Submit complete one-line diagram of service and
feeders; show conduit and wire sizes; specify
aluminum or copper conductors and type of insulation.
Indicate sizes of fuses and/or circuit breakers.
49. Submit electrical load calculations and/or panel
schedules.
50. Indicate ampere interrupting capacities (AIC) of
service and subservice equipment. NEC 230-98/110-9.
51. Add note to plans indicating:
All package A/C units shall be labeled by a
recognized electrical testing agency.
All light fixtures installed in suspended ceil-
ings shall be secured to the main and/or cross
runners with seismic clips unless installed in
accordance with other approved engineering.
All circuit breaker switched 120 VAC light
circuits, must use only type "SWD" circuit breakers.
NEC-110--3b
52. Indicate (a) existing building load, (b) added
building load per item 49, and (c) size of existing
service when new service is not required.
() LaA/?..-' SE)e. &i
d
... (A- :.),frfd4J
/':..- ,.• .5• '!,$,)
Sa,3,t.1, r CLW/7c&7Z 2-TC/C.3L f,9,4j 9•A?) 2pEa, fIc4
T/O'J.
Plan File No.____________ Jurisdiction C43'9L
Project Address ,E)OcEL&T T. Date I - 2-t
REMODEL OR TENANT IMPROVEMENT BUILDING CODE INFORMATION
In order, to complete a plan review of a remodel or tenant improvement
within an existing building it is necessary that the information in
Items 1-9 be provided or the approved plans be provided for the exist-
ing building.
& Circle the existing type of construction for this building:
I, II-FR., II-lhr., II-N, III-lhr., Ill-N, IV, V-lhr., V-N
Does this building have fire sprinklers throughout?
Yes No
Does the proposed project create a change in use or occupancy
classification?
Yes No
Describe the previous use of the project area
Describe the proposed use of the project area
CA Existing Building Area Improvement Area___________
How many stories are in this building?___________________________
What story is the improvement on?______________________________
C6) Does this project involve alterations to:
Existing fire walls Yes No
Existing floor or roof loads Yes No Existing building structure Yes No Existing HVAC equipment Yes No Existing electrical service loads Yes No
What is the approximate date that construction of the existing
building was completed?__________________________________________
ENERGY CONSERVATION
Which of the following were checked and approved for Title 24 Energy Conservation at the time the original building • was approved:
Building envelope Yes No • HVAC equipment Yes No Area lighting Yes No Water heating • Yes No
Will the proposed project significantly alter any element that was approved?Yes, No
HANDICAPPED ACCESS FACILITIES
Which of the following has been approved for compliance with
the handicapped access standards of Title 24, CAC:
Parking & access to the building Yes No Building entrance doors Yes No • Building stairs & elevators Yes No Existing public restrooms Yes No
Date________________ Information provided by:
Bldg. Dept. verification of information by:
102385 • •
DOCUMENTATION OF UNREASONABLE HARDSHIP
Job Address Plan File No.________________________
Owner Date
It is requested that the above named project be granted an exception from the requirements of
the State of California Title 24 accessibility, as specifically noted below:
I. EXCEPTIONS REQUESTED ESTIMATED COST OF ITEMS TO BE EXCEPTED
The cost of all construction without excepted items, is____________________________________
The impact on financial feasibility of the project, if the requested exception is not approved
is
The facility is used by the general public for the purpose of______________________________
The exceptions being requested will not penalize handicapped accessibility as equivalent
facilities are available as follows: (Complete if over $62,000 value in No. 2 above)_________
Exceptions requested, and data provided, by:
NAME
ADDRESS
SIGNATURE TELEPHONE
Department Use Only
Findings and Decision of the Enforcing Official:
Signature of Enforcing Official Date
HA-I 102385
TITLE 24 MANDATORY REQUIREMENTS
(To be noted on plans or specifications)
HVAC Controls
Sec. 2-5315.
(a) Each HVAC system shall:
Be equipped with at least one automatic device
for reducing HVAC energy use during periods of
nonuse or alternate uses of the building spaces
or zones served by the system;
Be able to maintain space temperature set points
from 55°F to 85°F. Two or more replaceable
fixed set-point devices shall be permitted if
installed so as to maintain space temperature
set points in the zone that they control;
Be able to provide sequential temperature
control of heating and cooling capacity in each
zone, if both heating and cooling are provided;
Provide a range of temperatures up to 10°F in
which no heating or cooling is provided to the
space, if the HVAC system has both heating and
cooling capability;
Be able to terminate all heating at 70°F or less;
and
Be able to terminate all cooling at 78°F or more.
EXCEPTION: Multiple zone HVAC sytems requiring
concurrent operation of independent heating and
cooling systems need not comply with Section
2-5315(a) 4, 2-5315 (a)5, and 2-5315(a)6.
(b) Zoning. Each zone shall be provided with at least
one of the devices specified in subsection (a) to
control the HVAC system which serves the zone. Each
floor of a building with conditioned space shall
contain at least one zone.
Ventilation Systems
Sec. 2-5316
On mechanical ventilation supply and, exhaust systems
capable of moving more than 5,000 cfm of air, auto-
matic dampers interlocked and closed on fan shut-
down shall be provided. On gravity ventilating
systems, either automatic or readily accessible
manually operated dampers in all openings to the
outside, other than combustion air openings,-shall
be provided.
Doors and Windows
Section 2-5317.
(a) Doors and windows between conditioned and uncon-
ditionéd spaces, such as garages and closets for
central forced air gas furnaces using outside air
for combustion, shall be designed to limit air
leakage into or from the building envelope.
Control Devices for Indoor Lighting
Sec. 2-5319. Controls for lighting loads within the
building envelope shall meet each of the following re-
quirements.
Each area enclosed by ceiling-height partitions
shall have independent control of the lighting
within that area.
Each area enclosed by ceiling-height partitions
shall have at least one readily accessible
manually operated switching device to control
lighting within the area. For lighting controls,
"readily accessible" means located so that a
person using the device can see the controlled
lights or the area being lit. Switching devices
in addition to, but not instead of, the required
readily accessible manually operated switching
devices shall also be permitted.
The general lighting of any area 100 square feet or
larger in which the connected lighting load equals
or exceeds 1.0 watt per square foot throughout the
entire area shall be controlled so that the load
may be reduced by at least one-half while maintain-
ing a reasonably uniform level of illumination
throughout the area. Readily accessible switches,
that control each luminaire in a space with more
than one luminaire, or that control each lamp in
a space independently meet the requirements of
this section.
In all areas where effective use may be made of
natural light, lighting circuiting shall be
arranged so that units, in all portions of the
area where natural light is available at the same
time, are switched independently of the remainder
of the area.
Occupant Operating and Maintenance Information to be
Provided by Builder
The builder shall provide the building" owner, manager,
and the original occupants a list of the heating,
cooling, water heating, and lighting systems
and features, materials, components, and mechanical
devices conservation or solar devices installed in
the building, and instructions on how to use
them efficiently. The instructions shall be con-
sistent with specifications set forth by the
Executive Director.
Water Heaters and Plumbing Fixtures
Water heaters, showerheads, lavatory faucets and
sink faucets must be certified by the California
Energy Commission (Excluding: waterheaters of the
non-storage electric type and lavatories in public
facilities having devices that limit the flow of
hot water or have self-closing faucets or having devices
that limit the outlet temperature to a maximum of
110°F) Section 2-5314, Table 2-53G.
TITLE 24 CONSTRUCTION COMPLIANCE STATEMENT REQUIREMENTS
(To be noted on plans or specifications)
CONSTRUCTION COMPLIANCE
(a) Prior to occupancy of the building, the person
responsible for the construction or installation
shall provide the building department a signed
statement, showing the building permit number,
and listing all the manufactured devices in-
stalled, including the name of the manufacturer,
model number date of manufacture, manufacturer's
stated efficiency, including the source cooling
power index, source heating power index and
fan performance index of each HVAC system. In
lieu of the list reference may be made to the
plans and specifications, if all the above in-
formation was contained in the plans and
soecifications.
Each document shall be signed by the person re-
sponsible for its preparation. The signer shall
be a civil engineer, mechanical engineer,
electrical engineer, architect, building designer,
general building contractor, or specialty con-
tractor, licensed or registered to practice by
the State of California; cr shall be the building
owner if he or she is allowed by law to prepare
the document. If more than one person has
responsibility for building design or construc-
tion, each person may prepare and sign the
document or documents applicable to that portion
of the design or construction for which the
person, was responsible; or the person with chief
responsibility for design or construction may
prepare and sign the document for the entire
design or construction.
INSULATION CERTIFICATION
Prior to occupancy the insulation installer
shall post in a conspicuous location in the build-
ing, a signed certificate containing the build-
ing permit number and stating the insulation was
installed in accordance with the approved plans
and specifications. The certificate should also
show the manufacturer's name, material identifi-
cation, "R" value and, for blown insulation, the
minimum weight per square foot consistent with
manufacturer's design data.
H
S
Datei_____
Prepared byt
/:1.,3c
Jurisdiction CAl(_Sf,q/D -
Bldg. Dept.
VALUATION AND PLA N CHECK FEE Q Esgi].
PLAN CHECK NO.
BUILDING ADDRESS zsoc kC.0S .JE-
APPLICANT/CONTACT (7E/ fUO- PHONE NO. 79- 71L4 ,
BUILDING OCCUPANCY -
2 DESIGNER PHONE_____________
TYPE OF CONSTRUCTION CONTRACTOR PHONE___________
BUILDING PORTION BUILDING AREA
-
VALUATION
MULTIPLIER
VALUE
TT .i. íe C-i 7-,,-t ' 11. U A rf Ok] 61 006
Air ConditioninE
Commercial
Residential
Res. or Comm.
Fire _Sprinklers
Total Value
I /0(000
1
Fee Adjusted To Reflect DEnergy Regulations (Fee x 1.1)
0 Handicapped Regulations (Fee x 1.065)
Building Permit Fee $
Plan Check Fee $ $ _ , 3'
COMMENTS:
S
8/4/82
CITY OF CARLSBAD - AGENDA BILL
AB#_________ TITLE: DEPT. HD._____
MTG.________ CITY AllY_____
DEPT._BLD CITY MGR._____
RECOMMENDED ACTION:
We ask the City Council to approve the decision of the Building Official as
expressed on the attached DOCUMENTATION OF UNREASONABLE HARDSHIP which is Exhibit 1.
ITEM EXPLANATION:
Peter Norby, Danish Bakery, i.s proposing to expand the use of his bakery to an
adjoining suite and establish, a tea room where his products will be served. There
is a small existing bathroom accessible to employees only. The Building Official
has determined that it would constitute an unreasonable hardship to require the
bathroom be made accessible to the handicapped. . The Disabled Access Regulations
require this,decision be ratified by the Appeals Board which is the City Council.
stipulated by Ordinance 8100.
The Building Official.proposes to grant an unreasonable hardship because the bathroom
exists, is used only by employees and would cost one third of the total cost of
the improvements.
FISCAL IMPACT
The cost, of creating access and providinga bathroom for the handicapped would
be $5000.
EXHIBITS:
Documentation of Unreasonable Hardship
Definition of Unreasonable Hardship
Excerpt from regulations concerning Unreasonable Hardship
z 0
-J
C.) z
0 0
DOCUMENTATION OF UNREASONABLE HARDSHIP
Job Address 2815 RooseVelt St" Plan File •
86-30
Owner Peter Norby Date 2/18/86
It is requested that the above named project be granted an exception from the requirements of
the State of California Title 24 accessibility, as specifically noted below: V
I. EXCEPTIONS; REQUESTED ESTIMATED COST OF ITEMS TO BE EXCEPTED
Handicap Bath in existing building
V $ 5000
The cost of all construction without excepted items, is $10,000
The impact on financial feasibility of the project, if the requested exception is not approved
is The project would not be built.
The facility is.used by the general public for the purpose ofused by employees only.
The exceptions being requested will not penalize hanicaoed accessibility as equivalent
facilities are available as follows: N/A LESS THAN $62,75100
S
Exceptions requested, and data provided, by: PETER NORBY
Peter Norby
NAME
2451 BuenaVista Circle Carlsbad, Calif
Department Use Only
Findings and Decision of the Enforcing Official:
The cost of providing a handicap bathroom is one-third of the total..cost of construction.
The tea room cannot be created if this is required. The bathroom is accessible only
tn mpinyoc There thre employees on each shift in the bakery.
MARTIN ORENYAK - 2/18/86
gnature of Enforcing Off I lal Date
#i 0. ,.•._I
EXHIBITS 2 and 3
EXCERPTS FROM TITLE 24, DISABLED ACCESS REGULATIONS
Equivalent facilitation is the most common exception to the specifications
of the regulations. As noted above, hardship is based on the monetary burden
of compliance unless the word "cost" includes opportunity costs.
No facilitation required if the following conditions are met.
Legal or physical constraints cause unreasonable hardship to providing
and facilitation.
The decision of the building official is ratified at a hearing in the
- appeals process.
(c) Unreasonable Hardship: An unreasonable hardship exists when the enforcing agency finds •that compliance with the building
standard would make the specific work of the project affected by the
building standard unfeasible, based upon an overall evaluation of
the following factors:
The cost of providing access.
The cost of all construction contemplated.
The impact of proposed improvements on financial feasibility
of the project.
The nature of the accessibility which would be gained or lost.
The nature of the use of the facility under construction and
its availability to handicapped persons.
The details of any finding of unreasonable hardship shall be recorded
and entered in the files of the enforcing agency.
W
Sec. 2-424.
Walk. Walk is a surfaced pedestrian way not located contiguous
to a street used by the public. (See definition for ''Sidewalk''.)
Wheelchair. Wheelchair is a chair mounted on wheels to be
propelled by its occupant manually or with the aid of electric
power, of a size and configuration conforming to the recognized
standard models of the trade.
Wheelchair Occupant or Wheelchair User. Wheelchair occupant or
wheelchair user is an individual who, due to a physical impairment
or disability, utilizes a wheelchair for mobility.
-19-
PLAN CHECK NUMBER " -2 ADDRESS DATE______________
PLANNING: TYPE OF STRUCTURE - ZONE:_______________
SCHOOL FEES: SAN DIEGUITO
ENCINITAS____________________
L&J
CARLSBAD
% COVERAGE________________________________
BUILDING HEIGHT_________________________
FENCES/WALLS________________________________
TWO CAR GARAGE
SAN MARCOS_____________________
REQUIRED SETBACKS______________
FRONT
SI
0 REDEVELOPMENT APPROVAL REQUIRED:
cr
ww F LANDSCAPE PLAN COMMENTS:_______
ENVIRONMENTAL REQUIRED:
ADDITIONAL COMMENTS: I /
OK TO ISS DATE:OK TO FINAL: DATE:_____________
ENGINEERING LEGAL DESCRIPTION VERIFIED? A.P.N. CHECKED?—
P.F.F. PARK IN LIEU
R.O.W: IMPROVEMENTS:
E. D. V . ii
SEWER:
LATERAL: DRIVEWAY:
GRADING PERMIT:
—1w I I- DRAINAGE:
(ñ EASEMENTS: COMMENTS .
• •
LAJ
A=lj 71
OK TO ISSUE: • DATE/ •
* ENGINEERING INSPECTION REQUIRED: •
_
PUBLIC WORKS INSPECTOR:
•
FINAL OK: DATE:
'* IF THIS ITEM IS NOT CHECKED, BUILDING DEPARTMENT WILL MAKE ALL INSPECTIONS
(DRIVEWAYS, CURB CUT, DRAINAGE, ETC.)
1200 ELM AVENUE
CARLSBAD, CA 92008-1989
TELEPHONE
(619) 438-5523
Citp of Car1tiab
FIRE DEPARTMENT
PLAN CHECK REPORT
PAGE 1 OF _L
APPROVED
DISAPPROVED
PLAN CHECK#
— 'O
PROJECT 1'#JANt F.a-,'r ADDRESS gaôc c'I4—
I
ARCHITECT Ati.'ac ADDRESS 7/2 c PHONE
OWNER ___________________________ ADDRESS 1' (IA. PHONE 71q-44cf
OCCUPANCY R CONST. ___________ TOTAL SQ. FT. ___________ STORIES
0 SPRINKLERED IETENANTIMP.
APPROVAL OF PLANS IS PREDICATED ON CONFORMING
TO THE FOLLOWING CONDITIONS AND/OR MAKING
THE FOLLOWING CORRECTIONS:
PLANS, SPECIFICATIONS, AND PERMITS
Provide one copy of: floor plan(s); site plan; sheets
Provide two site plans showing the location of all existing fire hydrants within 200 feet of the project.
3. Provide specifications for the following:
Permits are required for the installation of all fire protection systems (sprinklers, stand pipes, dry chemical, halon,
COa, alarms, hydrants). Plan must be approved by the fire department prior to installation.
The business owner shall complete a building information letter and return it to the fire department.
FIRE PROTECTION SYSTEMS AND EQUIPMENT
--7
The following fire protection systems are required:
Automatic fire sprinklers (Design Criteria:
O Dry Chemical, Halon, CO2 (Location:
Stand Pipes (Type:
Fire Alarm (Type/Location:
Fire Extinguisher Requirements:
aOne 2A rated ABC extinguisher for each ('O sq. ft. or portion thereof with a travel distance to the nearest
extinguisher not to exceed 75 feet of travel.
An extinguisher with a minimum rating of ________ to be located:
Other:
8. Additional fire hydrant(s) shall be provided
EXITS
......... 9. Exit doors shall be openable from the inside without the use of a key or any special knowledge or effort.
.......!.10. A sign stating, "This door to remain unlocked during business hours" shall be placed above the main exit and
doors i/(mi . ncsIJ d df
.......L..ii. EXIT signs (6" x 3/4" letters) shall be placed over all required exilts and directional signs located as necessary to
clearly indicate the location of exit doors.
GENERAL
..12. Storage, dispensing or use of any flammable or combustible liquids, flammable liquids, flammable gases and
hazardous chemicals shall comply with Uniform Fire Code.
_13. Building(s) not approved for high piled combustible stock. Storage in closely packed piles shall not exceed 15 feet
in height, 12 feet on pallets or in racks and 6 feet for tires, plastics and some flammable liquids. If high stock pil-
ing is to be done, comply with Uniform Fire Code, Article 81.
14. Additional Requirements.
_15. Comply with regulations on attached sheet(s)
Plan Examiner Date
-
Report mailed to architect _______ Met with Attach to Plans