Loading...
HomeMy WebLinkAbout2805 ROOSEVELT ST; ; 86-30; PermitI hereby affirm that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license is in full force and effect, Lic, No __________________ Class 'I hereby affirm that I am exempt from the Contrac- tors License Law for the following reason (See, 7031.5 Business and Professions Code: Any City or county which me-'quires a permit to Construct, alter, improve, demolish, or repair any structure, prior toils issuance also requires the ap- plicant tsr Such permit to tile a signed statement that he is licensed pursuant to the provisions 01 the Contractor's - License Law (Chapter 9 commencing with Section 7000 of Division 301 the Business and Professions Code) or that is ex- empt therefrom and the basis ten the alleged exemption. Any violation of Section 7031.5 by an applicant for a permit sub- jects the applicant to civil penalty 01 not more than tine hun- dred dollars ($500). . - C I, as owner 01 the properly, or my employees with wages as their sole compensation, will do the work, and the struc- ture is not intended or offered for sale (Soc. 7044. Business and Professions Code: The Contractors License Law does not apply to an owner of property who builds or improves thereon and who does such work himself or through his own employees, provided that such improvements are not intend- 0d or olfered for sale. If, however, the building or improve- ment is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or im- prove fur the purpose 01 sale). I, as owner 01 the properly, am exclusively contracting with licensed contractors to construct the project (Sec. 7044. Business and Professions Code: The Contractor's License Law dons not apply loan owner of properly who builds or im- proves thur005, and who contracts lot each projects with a contractor(s) license pursuant to the Contractors License Law). - O Ass homeowner lam improving my home, and the follow- ing conditions exist: I. The work is being performed prior to solo. . 2. I have lined in my home for twelve months prior to completion 01 this work. 0- 3. I have out claimed this exemption during the last three years. El lam exempt under Sec. ________________ . B & P.C. for this reason 0 111CF RAI I PAINT PN AM V L PRFt4t I1APfl APPLICANT TO FILL IN II'FORMATION WITHIN SHADED AREA AND DECLARATIONS. CARLSBAD BUILDING DEPARTMENT - APPLICATION & PERMIT' Carlsbad, California 92008-1989 (619) 438-5525 V. ST JOB ADDRESS . A D! NEAREST CROSS ST. I DATE OF APPLIC TION 9 E# - VALUATION PERMIT NUMBER Pt9D ZONi LO C CONTRACTO S PHONE C ]OCTOR BLOCK ' I0B0l VISION ; fl~SSESSOR OWNER' AM 73 OWNER 2ob%g( '•c•i' - . _______ __________________ __________________ OWNERS PHONE _______ ;7\ J CONTRACTOR'S ADDRESS LICENSE . PLAN I.D. # -WILDING SO. FOOTAGE ' __ _________________ Dr' 5S'77 OWNER'S MAILING ADDRESS DESIGNER DESIGNERS PHONE 8yIPTIONOF WORK . . DESIGNER'S ADDRESS LICENSE NO. ,'I'9B6B86 53 .., 0 \_!.IT •"D 7 - - ' NO - - - - F/P F LR ELEV. I. 0CC GP STORIES YO NO ___ NG SPACE RES UNITS GRADING PERMIT ISSUED I REDEVELOPMENT I I TYPE 0CC LOAD FIRE SPR CENSUS TRACT '713 GP LAND 1,!ARKU USE I AREA I I CONST - 0 N 0 V 0 No - YO N[3 Not Valid Unl s Machine Certified - CITY. PLUMBING PERMIT - ISSUE 7 -- QTY. MECHANICAL PERMIT - ISSUE 3 -- SUMMARY/ACCOUNT NUMBER ' — EACH FIXTURE TRAP . . . It? -, INSTALL FURN. DUCTS UP TO 100.000 BTU BUILDING PERMIT - 001-810-00-00-8220 21 EACHBUILDINGSEWER OVER 100,00Q . SIGN PERMIT 001-810-00-00-8221 EACHWATERHEATERAND/OR VENT BOILER/COMPRESSOR UP T0,,M'" PLAN CHECK 001-810-00-00-8806 EACH GAS SYSTEM 1 104 OUTLETS 80 1 LE R/MPRESSO2$IP , TOTAL PLUMBING 001-810-00-00-8222 ' EACH GAS SYSTEM 5 OR MO RE METAL FIREPLACE ELECTRICAL - 001-810-00-00-8223 3 — EACH 1NS1A1.. ALTER, REPAIRWATER PIPE VENT FAN S LEDUCT MECHANICAL 001-810-00-00-8224 EACH VACUUM BREAKER _ MECH AUST -HOOD/DUCTS MOBILEHOME 001-810-00-00-8225 WATER SOFTNER - CATION OF EA FURNACE/HEATER MOBILEHOME_PARK_INSP ' EACH ROOF DRAIN (INSIDE) ' - * : SOLAR 001-810-00-00-8226 _____ - TOTAL MECHANICAL - . STRONG MOTION 880-519-92-33 70 - TOTAL PLUMBING - FIRE SPRINKLERS 001-810-00-00-8227 PUBLIC FACILITIES FEE 332-810-00-00-8930 QTY. ELECTRICAL PERMIT - ISSUE . QTY. SOLAR -ISSUE NEW CONST EA AMPSWTIBKR , - ' COLLECTORS - SCHOOL FEE - DISTRICT 1 PH 3 PH ' STORAGE TANKS - Carlsbad EXIST BLDG EA AMP/SWT/BKR ROCK STORAGE - - Encinitas 1 PH 3 PH . . PUMP - San Dieguilo REMOOEL:ALTER PER CIRCUIT 2......._ PLAN CHECK FEE - San Marcos - TEMP POLE 200 AMS OVER 200 AMPS '. - - I , LICENSE TAX 001-810-00-00-8162 TEMP OCCUPANCY (30 DAYS) J - MFF 880-519-92-57 . - - - CREDIT DEPOSIT I 4 \f'- TOTAL ELECTRICAL T TOTAL, SOLAR 1 TOTAL FEES PAYABLE Zo I HAVE CAREFULLY EXAMINED THE COMPLETED "APPLICATION AND PERMIT" AND DO HEREBY Expiration. Every permit issued bythe Building Official under the provisions of this * AN OSHA PERMIT IS REQUIRED FOR EXCAVATIONS OVER CERTIFY UNDER PENALTY OF PERJURY THAT ALL INFORMATION HEREON INCLUDING THE I Code shall expire by limitation and become null and void, It the building or work 5'0- DEEP AND DEMOLITION OR CONSTRUCTION OF I authorized by such permit is not commenced within 180 days from the date of such DECLARATIONS ARE TRUE AND CORRECT AND I FURTHER CERTIFY AND AGREE IF A PERMIT IS I permit, or if ih.'uifding Or work a fhOrized by such- permit is suspended or STRUCTURES OVER 3 STORIES IN HEIGHT ISSUED: TO COMPLY WITH ALL CITY, COUNTY AND STATE LAWS GOVERNING BUILDING CON' I abandoned )al'n,/Iir'after the won is commenced for a eriod of 180 days STRUCTION. WHETHER SPECIFIED HEREIN OR NOT. I ALSO AGREE TO SAVE INDEMNIFY AND OWNER CONTRACTOR 0 APPRO VD BY KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES. JUDGMENTS, COSTS AND WHICH WAY ACCRUE AGAINST SAID CITY IN CONSEOUCNCE OF THE EXPENSES MAY IN ANY GRANTING OF THIS PERMIT. BY PHONE ('3 ,I VA Cl thereby affirm that I have a certificate of consent to aell.insure. or certificate 01 Workers* Compensation In. - surance. or a certified copy thereof (Sec. 3800. Labor Code) POLICY NO. C COMPANY Copy is flied with the city Certified copy is hereby furnished CERTIFICATE OF EXEMPTION FROM WORKERS' COMPENSATION INSURANCE (This section need not be completed lithe permit is br one hundred dollars (5100) or less) I certify' 'hat in the performance of the work for which this permit in innued. I shalt not employ any person in any manner so auto become subject to the Workers' Compen. nation Laws of California. NOTICE TO APPLICANT: II. atler making this Certificate of Exemption, you should become subject to the Workers' Compensation provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked, - r 0 I hereby affirm that there In a construction lending fall agency for the performance of the work for which this per. 0 mit is issued (Sec. 3097. Civil Cede) z W Lender's Name_________________________________ _J Lenders Address FIELD INSPECTION RECORD REQUIRED SPECIAL INSPECTIONS REQ IF INSPECTORS INSPECTION CHECKED APPROVAL DATE SOILS COMPLIANCE PRIOR TO FOUNDATION INSP STRUCTURAL CONCRETE OVER 2000 PSI PRESTRESSED CONCRETE POST TENSIONED CONCRETE FIELD WELDING HIGH STRENGTH BOLf S SPECIAL MASON- PILES CAISSONS INSPECTOR'S N . : -.... k - •" ;. -' 1 !' H 4, TYPE i DATE INSPECTOR BUILDING FOUNDATION REINFORCED STEEL MASONRY GUN ITE OR GROUT SUB FRAME 0 FLOOR 0 CEILLING SHEATHING 0 ROOF 0 S1EAR FRAME EXTERIOR LATH INSULATION INTERIOR LATH & DRYWALL PLUMBING O SEWER AND BL/CO 0 PL/CO - I - UNDERGROUND DWASTE Di WATER TOP OUT DWASTE DVIATER TUB AND SHOWER PAN GAS TEST O WATER HEATER 0 SOLAR WTER ELECTRICAL O ELECTRIC UNDERGROUND 0 UFFER ROUGH ELECTRIC .' o ELECTRIC SERVICE 0 TEMPORARY O BONDING 0 POOL MECHANICAL O DUCT & PLEM., 0 REF. PIPIJG HEAT - AIR COND. SYSTEMS VENTILATING SYSTEMS H.. . -. CALL FOR FINAL INSPECTION WHEN ALL APPROPRIATE ITEMS ABOVE HAVE BEEN APPROVED FINAL PLUMBING ELECTRICAL MECHANICAL GAS BUILDING SPECIAL CONDITIONS FINAL BUILDING INSPECTION PLAN CHECK NUMBER: 2805 RoOBQVOlt DATE: 4-9-86 PROJECT NAME: Convert hbhk store to tearoom 2805 Roosuv1t ADDRESS: PROJECT NO.: UNIT NUMBER: _________________ PHASE NO.: TYPE OF UNIT: T. 1.NUMBER OF UNITS: CONTACT PERSON: Peter CONTACT TELEPHONE: 129-61UG BY: _______________________ INSPECTED: ____________ APPROVED DISAPPROVED INSPECTED DATE INSPECTED DATE BY: INSPECTED: ____________ APPROVED ______ DISAPPROVED INSPECTED DATE BY: ________________________ INSPECTED: ____________ APPROVED. ______ DISAPPROVED COMMENTS: . . . Rev. 1186 WHITE: Suspense GREEN: Engineering CANARY: Utilities PINK: Planning Fi ESGIL CORPORATION 9320 CHESAPEAKE DR.. SUITE 208 SAN I)IEGO, CA 92123 (6W) 560-1468 DATE: 1 i16 DAPPLICANT JURISDICTION JURISDICTION: Ciic.L, i3eD PLAN CHECKER 0 FILE COPY PLAN CHECK NO: DS 0 DESIGNER PROJECT ADDRESS: PROJECT NAME: The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficien- cies identified are resolved and checked by building departnient staff. The plans transmitted herewith have significant deficiencies identified on. the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is the jurisdiction's copy for your information. The plans are being held at un Esgil Corp. until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to return to the applicant contact person. The applicant's copy of the check list has been sent to:- 7-9 R L S /.-3 Ct). ?2CCV Esgil staff did not advise the applicant contact person that plan check has been completed. I Esgil staff did advise applicant that the plan check has been completed. Person contacted: Date contacted: Telephone # REMARKS: BY: 1-1(36 lHii ENCL:_______________ ESGIL CORPORATION JURISDICTION OF T0:FEiE1 'O/3'-) ( I APPLICANT COPY 2ROc Cs -47 37 ( I JURISDICTION C)t,-ip c-J.. ( I PLAN CHECKER COPY r ' ESGIL FILE COPY TENANT IMPROVEMENT & INTERIOR ALTERATION CORRECTION SHEET Plan Check Number 30 Site Address _7C(€t'EL7_Sr Owner /9 7 ( k10i3 (/ Building Code Applicable 1982tJ.B.C. Occupant Load Stories____________________ Previous Proposed Proposed Occupancy Occupancy _____Use lEA /2c7'-j Type of Construction A/Sprinklers: Yes Allowable Floor Area Actual____________________ Basis for Area Increase_________________________________________ - J. Remarks Date Plan Submitted:to Jurisdiction- to Esgil I-? Date Initial Plan Check Completed (__2-_'C By 14R97 ZX./E1J7 Applicant Contact Person P&T&/CO/Tel. 7Z/'- FOREWORD: PLEASE READ I. This plan check is limited to technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and State laws regulating energy conservation, noise attenuation and access for the handicapped. The plan check is based on regulations enforced by the Building Inspection Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department or other departments. For information regarding those departments, please contact those departments. The items listed below require plan clarification, modification or change. All items have to be satisfied before the plans will be in conformance with the cited codes and regulations. Per Section 303(c), 1982 Uniform Building Code, the approval of the plans does not permit the violation of any State, County or City law. () Please submit two sets of corrected plans and enclose a copy of this list with your notes indicating where corrections were made i.e., sheet, detail, etc ...return corrected plans and documents ONLY to the locations checked below: Esgil Corporation at 9320 Chesapeake Dr., Suite 268, San Diego, CA, 92123 Telephone (619) 560-1468 0 Jurisdiction Building Department - - 10/22/85 C5) The responsible designer is required to sign ' each flgt_of the plans. A State-licensed Architect or Engineer is required where there are structural changes to an existing building or a structural addition. (Business and Professions Code) V Provide the correct address and suite number of tenant space on the plans. Section 302 Provide a note on the plan indicating the previous use of the tenant space or building being remodeled. Section 302 When the character of the occupancy or use changes within a building,the building must be made to comply with current Building Code requirements for the new occupancy. Please provide complete details to show the building will comply. Section 502 09 UBC Section 304 requires the Building Official to determine the total value of all construction work proposed under this permit. The value shall in- clude all finish work, painting, roofing, electrical, plumbing, heating, air conditioning, elevator, fire extinguishing systems and any other permanent equipment. Please provide a signed copy of the designer's or contractor's construction cost estimate of all work proposed. Provide a plot plan showing the distances from the building to the property lines and the location of tenant space (or remodel) within the building. On the first sheet of the plans indicate: Type of construction of the existing building, present and proposed occupancy classifications of the remodel area and the occupant load of the remodel areas and total building area. Specify on the plan title sheet the Building Code Edition used for the design of the proposed work. Provide a plan showing the size and use of all rooms or ireas within the space being improved or altered. Draw the plan to scale and indicate the scale on the plan. Indicate the use of all spaces adjacent to the area being remodeled or improved. Show any existing fire rated area separation walls, occupancy separation walls, shafts or rated corridors. Identify and provide con- struction details for proposed new fire rated walls. Specify on the plans the fire ratings of / assemblies to protect proposed openings in existing or new fire walls. Identify existing walls to be removed, existing walls to remain and proposed new walls. Identify bearing walls, non-bearing walls, and shear walls. (3. ceALc.i /o&fTIFI C.A) qo-qa tWOfl.- /c1WS 77-/& L/M'rS OF THE_ ..JOI3 cOL'ee&D tc/JDE' 'i/-H i7FiLft(tr ,rf'L'cMyIoI\J. Provide a section view of all new interior partitions. Show: Type, size and spacing of studs. Indicate gauge for metal studs. Specify manufacturer and approval number or indicate "to be ICBO approved". Method of attaching top and bottom plates to structure. (NOTE: Top or partition must be secured to roof or floor framing, unless suspended ceiling has been designed for partition lateral load.) Wall sheathing material and details of attachment. (Size and spacing of fasteners). Height of partition and suspended ceiling. Provide notes and/or details to show that the floor and wall finish in toilet rooms are surfaced with a smooth hard non-absorbent material extending five inches up the wall. Similar surfacing shall be provided on the walls from the floor to a height of 4 feet around urinals and within water closet compartments. Note on the plan: "All interior finishes must comply with Chapter 42 of the rJBC". Specify "class flame spread rating (minimum) for Lateral bracing for suspended ceiling must be provided. (UBC Table 23-J Where ceiling loads are less than 5 PSF and not supporting interior partitions, ceiling bracing shall be provided by four No. 12 gauge wires secured to the main runner within 2 inches of the cross runner intersection and splayed 900 from each other at an angle not exceeding 45° from the plane of the ceiling. These horizontal restraint points shall be placed 12 feet o.c. in both directions with the first point within 4 feet of each wall. Attach- ment of restraint wires to the structure above shall be adequate for the load imposed.. 2,2< Draft stop and suspended ceiling in wood frame floor / construction every 1,000 sq. ft. and in attics of combustible construction every 3,000 sq. ft. The maximum distance allowed between draft stops is 60 feet. Section 2516(f) The tenant space and new and/or existing facilities / serving the remodeled area must be accessible to and functional for the physically handicapped. See the attached correction sheet. Title 24, Part 2 Show the exit sign locations; show any required directional -exit signs. Section 3314 Rooms with more than 10 occupants may have one exit through one adjoining room. Revise exits to comply. Section 3303(e) )i. Two complying exits are required from Exits must be, and maintain, a distance apart of at least 1/2 the maximum diagonal dimension of the area served by the exits. Section 3303 3/ Assembly rooms with more than 50 occupants shall not have a lock or latch on exit doors unless they are equipped with panic hardware. Section 3318. (D8- Note on the plans: "All exits are to be openable from inside without use of a key or special know- ledge". Section 3304(c). Or NOTE: "Provide a sign on or near the exit doors reading: THIS DOOR TO REMAIN UNLOCKED DURING BUSINESS HOURS", and meet all other criteria of Section 3304(c) 1. (2, Required exit doorways shall be not less than 36 inches in width and not less than 6 feet - 8 inches in height. Section 3304(e) Exit doors shall swing in the direction of exit travel (occupant load exceeds 50). Section 3304(b). 3/ Show the locations of existing exits from the build- ing and show the path of travel from the remodel area to the existing exits. corridors must provide continuous protection to the exterior of the building. Interruptions by inter- vening room is not permitted. Foyers, lobbies or reception rooms constructed as required for corridors are not considered intervening rooms. DcOiz c3I2E. 7HE Et/Y Pee`), Show exit corridors as 44 inches wide minimum. Dead- end corridors are limited to 20 feet when more than one exit is required from the corridor. Section 3305 Provide one-hour construction details for ( all corridor walls and ceilings serving an occupant load of 30 or more. Identify all rated corridors. Walls of reception rooms and lobbies which are included within pro- tected corridors must have walls and ceil- ings constructed as required for corridors. Protect all interior openings in corridor walls and ceilings. Door and frame must be labeled 20-minute smoke and draft control assembly with self-closers or automatic closers with smoke detectors. Section 3305(h). Glazing must be 1/4 inch-thick wired glass installed in steel frames and cannot exceed 25 percent of the common wall area. Section 3305(h)2. Show the location of fire dampers. Provide fire dampers at duct penetrations of fire-rated occupancy and area separations, shafts and corridor walls and ceilings. Section 4306(j) 37X' Provide mechanical ventilation in all rooms capable ( of supplying a minimum of 5 cubic feet per minute of outside air with a total circulation of not less than 15 cubic feet per minute per occupant. Section 605 and 705 3,/ If the tenant improvement area will not have a / comfort heating or cooling system consuming more than 5 BTU per hour per square foot, note on the plan "Tenant Improvement area is not heated or cooled more than 5 BTU per hour per square foot and is exempt from Energy Conservation Regulations". If the tenant improvement area will have a comfort heating or cooling system consuming more than 5 BTU per hour per square foot, note on the plan "Tenant Improvement must comply with Energy Conservation Regulations". If the tenant improvement area must comply with the energy conservation regulations and the exist- ing building was originally constructed in com- pliance with the energy conservation regulations, provide two copies of the original Energy Com- pliance Documentation forms. If the tenant improvement area must comply with the Energy Conservation Regulations and the exist- ing building was not originally constructed in compliance with the Energy Conservation Regulations, address the appropriate items that will follow. If HVAC is to be installed, provide two sets of energy conservation compliance forms 1, 2, 3, 4, and 6. Title 24 Section 2-5312. If HVAC is to be installed, provide two sets of HVAC plans. Title 24 Section 2-5306. 41. If lighting is to be installed, provide two sets of energy conservation compliance form 5. Title 24 Sections 2-5343 & 2-5344. If HVAC is to be installed, incorporate in the plans or specifications, the attached "Title 24 Mandatory Requirements". If HVAC is to be installed, the required energy documentation required to show compliance with the energy conservation requirements, is required to be signed by the California licensed person responsible for its preparation. Title 20 Section 1403(a)l. If HVAC is to be installed, recent charges in the regulations required specific signed construction compliance statements be filed with the Building Department prior to use or occupancy of the im- proved area. Incorporate in the plans or specifications the attached "Title 24-Construction Compliance Statement Requirements". 41 Structural design calculations are required to show code compliance if any of the following conditions exist. Section 302(b): Alteration of existing vertical or horizontal load carrying structure. Increase in live or dead loads on floors or roof. Other______________________________________ ELECTRICAL 48. Submit complete one-line diagram of service and feeders; show conduit and wire sizes; specify aluminum or copper conductors and type of insulation. Indicate sizes of fuses and/or circuit breakers. 49. Submit electrical load calculations and/or panel schedules. 50. Indicate ampere interrupting capacities (AIC) of service and subservice equipment. NEC 230-98/110-9. 51. Add note to plans indicating: All package A/C units shall be labeled by a recognized electrical testing agency. All light fixtures installed in suspended ceil- ings shall be secured to the main and/or cross runners with seismic clips unless installed in accordance with other approved engineering. All circuit breaker switched 120 VAC light circuits, must use only type "SWD" circuit breakers. NEC-110--3b 52. Indicate (a) existing building load, (b) added building load per item 49, and (c) size of existing service when new service is not required. () LaA/?..-' SE)e. &i d ... (A- :.),frfd4J /':..- ,.• .5• '!,$,) Sa,3,t.1, r CLW/7c&7Z 2-TC/C.3L f,9,4j 9•A?) 2pEa, fIc4 T/O'J. Plan File No.____________ Jurisdiction C43'9L Project Address ,E)OcEL&T T. Date I - 2-t REMODEL OR TENANT IMPROVEMENT BUILDING CODE INFORMATION In order, to complete a plan review of a remodel or tenant improvement within an existing building it is necessary that the information in Items 1-9 be provided or the approved plans be provided for the exist- ing building. & Circle the existing type of construction for this building: I, II-FR., II-lhr., II-N, III-lhr., Ill-N, IV, V-lhr., V-N Does this building have fire sprinklers throughout? Yes No Does the proposed project create a change in use or occupancy classification? Yes No Describe the previous use of the project area Describe the proposed use of the project area CA Existing Building Area Improvement Area___________ How many stories are in this building?___________________________ What story is the improvement on?______________________________ C6) Does this project involve alterations to: Existing fire walls Yes No Existing floor or roof loads Yes No Existing building structure Yes No Existing HVAC equipment Yes No Existing electrical service loads Yes No What is the approximate date that construction of the existing building was completed?__________________________________________ ENERGY CONSERVATION Which of the following were checked and approved for Title 24 Energy Conservation at the time the original building • was approved: Building envelope Yes No • HVAC equipment Yes No Area lighting Yes No Water heating • Yes No Will the proposed project significantly alter any element that was approved?Yes, No HANDICAPPED ACCESS FACILITIES Which of the following has been approved for compliance with the handicapped access standards of Title 24, CAC: Parking & access to the building Yes No Building entrance doors Yes No • Building stairs & elevators Yes No Existing public restrooms Yes No Date________________ Information provided by: Bldg. Dept. verification of information by: 102385 • • DOCUMENTATION OF UNREASONABLE HARDSHIP Job Address Plan File No.________________________ Owner Date It is requested that the above named project be granted an exception from the requirements of the State of California Title 24 accessibility, as specifically noted below: I. EXCEPTIONS REQUESTED ESTIMATED COST OF ITEMS TO BE EXCEPTED The cost of all construction without excepted items, is____________________________________ The impact on financial feasibility of the project, if the requested exception is not approved is The facility is used by the general public for the purpose of______________________________ The exceptions being requested will not penalize handicapped accessibility as equivalent facilities are available as follows: (Complete if over $62,000 value in No. 2 above)_________ Exceptions requested, and data provided, by: NAME ADDRESS SIGNATURE TELEPHONE Department Use Only Findings and Decision of the Enforcing Official: Signature of Enforcing Official Date HA-I 102385 TITLE 24 MANDATORY REQUIREMENTS (To be noted on plans or specifications) HVAC Controls Sec. 2-5315. (a) Each HVAC system shall: Be equipped with at least one automatic device for reducing HVAC energy use during periods of nonuse or alternate uses of the building spaces or zones served by the system; Be able to maintain space temperature set points from 55°F to 85°F. Two or more replaceable fixed set-point devices shall be permitted if installed so as to maintain space temperature set points in the zone that they control; Be able to provide sequential temperature control of heating and cooling capacity in each zone, if both heating and cooling are provided; Provide a range of temperatures up to 10°F in which no heating or cooling is provided to the space, if the HVAC system has both heating and cooling capability; Be able to terminate all heating at 70°F or less; and Be able to terminate all cooling at 78°F or more. EXCEPTION: Multiple zone HVAC sytems requiring concurrent operation of independent heating and cooling systems need not comply with Section 2-5315(a) 4, 2-5315 (a)5, and 2-5315(a)6. (b) Zoning. Each zone shall be provided with at least one of the devices specified in subsection (a) to control the HVAC system which serves the zone. Each floor of a building with conditioned space shall contain at least one zone. Ventilation Systems Sec. 2-5316 On mechanical ventilation supply and, exhaust systems capable of moving more than 5,000 cfm of air, auto- matic dampers interlocked and closed on fan shut- down shall be provided. On gravity ventilating systems, either automatic or readily accessible manually operated dampers in all openings to the outside, other than combustion air openings,-shall be provided. Doors and Windows Section 2-5317. (a) Doors and windows between conditioned and uncon- ditionéd spaces, such as garages and closets for central forced air gas furnaces using outside air for combustion, shall be designed to limit air leakage into or from the building envelope. Control Devices for Indoor Lighting Sec. 2-5319. Controls for lighting loads within the building envelope shall meet each of the following re- quirements. Each area enclosed by ceiling-height partitions shall have independent control of the lighting within that area. Each area enclosed by ceiling-height partitions shall have at least one readily accessible manually operated switching device to control lighting within the area. For lighting controls, "readily accessible" means located so that a person using the device can see the controlled lights or the area being lit. Switching devices in addition to, but not instead of, the required readily accessible manually operated switching devices shall also be permitted. The general lighting of any area 100 square feet or larger in which the connected lighting load equals or exceeds 1.0 watt per square foot throughout the entire area shall be controlled so that the load may be reduced by at least one-half while maintain- ing a reasonably uniform level of illumination throughout the area. Readily accessible switches, that control each luminaire in a space with more than one luminaire, or that control each lamp in a space independently meet the requirements of this section. In all areas where effective use may be made of natural light, lighting circuiting shall be arranged so that units, in all portions of the area where natural light is available at the same time, are switched independently of the remainder of the area. Occupant Operating and Maintenance Information to be Provided by Builder The builder shall provide the building" owner, manager, and the original occupants a list of the heating, cooling, water heating, and lighting systems and features, materials, components, and mechanical devices conservation or solar devices installed in the building, and instructions on how to use them efficiently. The instructions shall be con- sistent with specifications set forth by the Executive Director. Water Heaters and Plumbing Fixtures Water heaters, showerheads, lavatory faucets and sink faucets must be certified by the California Energy Commission (Excluding: waterheaters of the non-storage electric type and lavatories in public facilities having devices that limit the flow of hot water or have self-closing faucets or having devices that limit the outlet temperature to a maximum of 110°F) Section 2-5314, Table 2-53G. TITLE 24 CONSTRUCTION COMPLIANCE STATEMENT REQUIREMENTS (To be noted on plans or specifications) CONSTRUCTION COMPLIANCE (a) Prior to occupancy of the building, the person responsible for the construction or installation shall provide the building department a signed statement, showing the building permit number, and listing all the manufactured devices in- stalled, including the name of the manufacturer, model number date of manufacture, manufacturer's stated efficiency, including the source cooling power index, source heating power index and fan performance index of each HVAC system. In lieu of the list reference may be made to the plans and specifications, if all the above in- formation was contained in the plans and soecifications. Each document shall be signed by the person re- sponsible for its preparation. The signer shall be a civil engineer, mechanical engineer, electrical engineer, architect, building designer, general building contractor, or specialty con- tractor, licensed or registered to practice by the State of California; cr shall be the building owner if he or she is allowed by law to prepare the document. If more than one person has responsibility for building design or construc- tion, each person may prepare and sign the document or documents applicable to that portion of the design or construction for which the person, was responsible; or the person with chief responsibility for design or construction may prepare and sign the document for the entire design or construction. INSULATION CERTIFICATION Prior to occupancy the insulation installer shall post in a conspicuous location in the build- ing, a signed certificate containing the build- ing permit number and stating the insulation was installed in accordance with the approved plans and specifications. The certificate should also show the manufacturer's name, material identifi- cation, "R" value and, for blown insulation, the minimum weight per square foot consistent with manufacturer's design data. H S Datei_____ Prepared byt /:1.,3c Jurisdiction CAl(_Sf,q/D - Bldg. Dept. VALUATION AND PLA N CHECK FEE Q Esgi]. PLAN CHECK NO. BUILDING ADDRESS zsoc kC.0S .JE- APPLICANT/CONTACT (7E/ fUO- PHONE NO. 79- 71L4 , BUILDING OCCUPANCY - 2 DESIGNER PHONE_____________ TYPE OF CONSTRUCTION CONTRACTOR PHONE___________ BUILDING PORTION BUILDING AREA - VALUATION MULTIPLIER VALUE TT .i. íe C-i 7-,,-t ' 11. U A rf Ok] 61 006 Air ConditioninE Commercial Residential Res. or Comm. Fire _Sprinklers Total Value I /0(000 1 Fee Adjusted To Reflect DEnergy Regulations (Fee x 1.1) 0 Handicapped Regulations (Fee x 1.065) Building Permit Fee $ Plan Check Fee $ $ _ , 3' COMMENTS: S 8/4/82 CITY OF CARLSBAD - AGENDA BILL AB#_________ TITLE: DEPT. HD._____ MTG.________ CITY AllY_____ DEPT._BLD CITY MGR._____ RECOMMENDED ACTION: We ask the City Council to approve the decision of the Building Official as expressed on the attached DOCUMENTATION OF UNREASONABLE HARDSHIP which is Exhibit 1. ITEM EXPLANATION: Peter Norby, Danish Bakery, i.s proposing to expand the use of his bakery to an adjoining suite and establish, a tea room where his products will be served. There is a small existing bathroom accessible to employees only. The Building Official has determined that it would constitute an unreasonable hardship to require the bathroom be made accessible to the handicapped. . The Disabled Access Regulations require this,decision be ratified by the Appeals Board which is the City Council. stipulated by Ordinance 8100. The Building Official.proposes to grant an unreasonable hardship because the bathroom exists, is used only by employees and would cost one third of the total cost of the improvements. FISCAL IMPACT The cost, of creating access and providinga bathroom for the handicapped would be $5000. EXHIBITS: Documentation of Unreasonable Hardship Definition of Unreasonable Hardship Excerpt from regulations concerning Unreasonable Hardship z 0 -J C.) z 0 0 DOCUMENTATION OF UNREASONABLE HARDSHIP Job Address 2815 RooseVelt St" Plan File • 86-30 Owner Peter Norby Date 2/18/86 It is requested that the above named project be granted an exception from the requirements of the State of California Title 24 accessibility, as specifically noted below: V I. EXCEPTIONS; REQUESTED ESTIMATED COST OF ITEMS TO BE EXCEPTED Handicap Bath in existing building V $ 5000 The cost of all construction without excepted items, is $10,000 The impact on financial feasibility of the project, if the requested exception is not approved is The project would not be built. The facility is.used by the general public for the purpose ofused by employees only. The exceptions being requested will not penalize hanicaoed accessibility as equivalent facilities are available as follows: N/A LESS THAN $62,75100 S Exceptions requested, and data provided, by: PETER NORBY Peter Norby NAME 2451 BuenaVista Circle Carlsbad, Calif Department Use Only Findings and Decision of the Enforcing Official: The cost of providing a handicap bathroom is one-third of the total..cost of construction. The tea room cannot be created if this is required. The bathroom is accessible only tn mpinyoc There thre employees on each shift in the bakery. MARTIN ORENYAK - 2/18/86 gnature of Enforcing Off I lal Date #i 0. ,.•._I EXHIBITS 2 and 3 EXCERPTS FROM TITLE 24, DISABLED ACCESS REGULATIONS Equivalent facilitation is the most common exception to the specifications of the regulations. As noted above, hardship is based on the monetary burden of compliance unless the word "cost" includes opportunity costs. No facilitation required if the following conditions are met. Legal or physical constraints cause unreasonable hardship to providing and facilitation. The decision of the building official is ratified at a hearing in the - appeals process. (c) Unreasonable Hardship: An unreasonable hardship exists when the enforcing agency finds •that compliance with the building standard would make the specific work of the project affected by the building standard unfeasible, based upon an overall evaluation of the following factors: The cost of providing access. The cost of all construction contemplated. The impact of proposed improvements on financial feasibility of the project. The nature of the accessibility which would be gained or lost. The nature of the use of the facility under construction and its availability to handicapped persons. The details of any finding of unreasonable hardship shall be recorded and entered in the files of the enforcing agency. W Sec. 2-424. Walk. Walk is a surfaced pedestrian way not located contiguous to a street used by the public. (See definition for ''Sidewalk''.) Wheelchair. Wheelchair is a chair mounted on wheels to be propelled by its occupant manually or with the aid of electric power, of a size and configuration conforming to the recognized standard models of the trade. Wheelchair Occupant or Wheelchair User. Wheelchair occupant or wheelchair user is an individual who, due to a physical impairment or disability, utilizes a wheelchair for mobility. -19- PLAN CHECK NUMBER " -2 ADDRESS DATE______________ PLANNING: TYPE OF STRUCTURE - ZONE:_______________ SCHOOL FEES: SAN DIEGUITO ENCINITAS____________________ L&J CARLSBAD % COVERAGE________________________________ BUILDING HEIGHT_________________________ FENCES/WALLS________________________________ TWO CAR GARAGE SAN MARCOS_____________________ REQUIRED SETBACKS______________ FRONT SI 0 REDEVELOPMENT APPROVAL REQUIRED: cr ww F LANDSCAPE PLAN COMMENTS:_______ ENVIRONMENTAL REQUIRED: ADDITIONAL COMMENTS: I / OK TO ISS DATE:OK TO FINAL: DATE:_____________ ENGINEERING LEGAL DESCRIPTION VERIFIED? A.P.N. CHECKED?— P.F.F. PARK IN LIEU R.O.W: IMPROVEMENTS: E. D. V . ii SEWER: LATERAL: DRIVEWAY: GRADING PERMIT: —1w I I- DRAINAGE: (ñ EASEMENTS: COMMENTS . • • LAJ A=lj 71 OK TO ISSUE: • DATE/ • * ENGINEERING INSPECTION REQUIRED: • _ PUBLIC WORKS INSPECTOR: • FINAL OK: DATE: '* IF THIS ITEM IS NOT CHECKED, BUILDING DEPARTMENT WILL MAKE ALL INSPECTIONS (DRIVEWAYS, CURB CUT, DRAINAGE, ETC.) 1200 ELM AVENUE CARLSBAD, CA 92008-1989 TELEPHONE (619) 438-5523 Citp of Car1tiab FIRE DEPARTMENT PLAN CHECK REPORT PAGE 1 OF _L APPROVED DISAPPROVED PLAN CHECK# — 'O PROJECT 1'#JANt F.a-,'r ADDRESS gaôc c'I4— I ARCHITECT Ati.'ac ADDRESS 7/2 c PHONE OWNER ___________________________ ADDRESS 1' (IA. PHONE 71q-44cf OCCUPANCY R CONST. ___________ TOTAL SQ. FT. ___________ STORIES 0 SPRINKLERED IETENANTIMP. APPROVAL OF PLANS IS PREDICATED ON CONFORMING TO THE FOLLOWING CONDITIONS AND/OR MAKING THE FOLLOWING CORRECTIONS: PLANS, SPECIFICATIONS, AND PERMITS Provide one copy of: floor plan(s); site plan; sheets Provide two site plans showing the location of all existing fire hydrants within 200 feet of the project. 3. Provide specifications for the following: Permits are required for the installation of all fire protection systems (sprinklers, stand pipes, dry chemical, halon, COa, alarms, hydrants). Plan must be approved by the fire department prior to installation. The business owner shall complete a building information letter and return it to the fire department. FIRE PROTECTION SYSTEMS AND EQUIPMENT --7 The following fire protection systems are required: Automatic fire sprinklers (Design Criteria: O Dry Chemical, Halon, CO2 (Location: Stand Pipes (Type: Fire Alarm (Type/Location: Fire Extinguisher Requirements: aOne 2A rated ABC extinguisher for each ('O sq. ft. or portion thereof with a travel distance to the nearest extinguisher not to exceed 75 feet of travel. An extinguisher with a minimum rating of ________ to be located: Other: 8. Additional fire hydrant(s) shall be provided EXITS ......... 9. Exit doors shall be openable from the inside without the use of a key or any special knowledge or effort. .......!.10. A sign stating, "This door to remain unlocked during business hours" shall be placed above the main exit and doors i/(mi . ncsIJ d df .......L..ii. EXIT signs (6" x 3/4" letters) shall be placed over all required exilts and directional signs located as necessary to clearly indicate the location of exit doors. GENERAL ..12. Storage, dispensing or use of any flammable or combustible liquids, flammable liquids, flammable gases and hazardous chemicals shall comply with Uniform Fire Code. _13. Building(s) not approved for high piled combustible stock. Storage in closely packed piles shall not exceed 15 feet in height, 12 feet on pallets or in racks and 6 feet for tires, plastics and some flammable liquids. If high stock pil- ing is to be done, comply with Uniform Fire Code, Article 81. 14. Additional Requirements. _15. Comply with regulations on attached sheet(s) Plan Examiner Date - Report mailed to architect _______ Met with Attach to Plans