HomeMy WebLinkAbout2808 CACATUA ST; ; CB071875; Permit09-20-2007
Job Address
Permit Type
Parcel No
Valuation
Occupancy Group
# Dwelling Units
Bedrooms
Project Title
Applicant
RDA DESIGNS
City of Carlsbad
1635 Faraday Av Carlsbad, CA 92008
Residential Permit Permit No CB071875
Building Inspection Request Line (760) 602-2725
2808 CACATUA ST CBAD
RESDNTL Sub Type RAD
2153700200 Lot# 0
$22,082 00 Construction Type NEW
Reference #
0 Structure Type
0 Bathrooms 0
MALLOY RESIDENCE
181 SF ADDITION, ENTRY & DINING ROOM
Status
Applied
Entered By
Plan Approved
Issued
Inspect Area
Ong PC#
Plan Check#
ISSUED
07/13/2007
MDP
09/20/2007
09/20/2007
Owner
MALLOY BRIAN&MARY
PO BOX 40
CARLSBAD CA 92018
760 729-8099
428 LAVENTURE
MTVERNON WA 98273
Building Permit
Add'l Building Permit Fee
Plan Check
Add'l Plan Check Fee
Plan Check Discount
Strong Motion Fee
Park in Lieu Fee
Park Fee
LFM Fee
Bridge Fee
Other Bridge Fee
BTD #2 Fee
BID #3 Fee
Renewal Fee
Add'l Renewal Fee
Other Building Fee
HMP Fee
Pot Water Con Fee
Meter Size
Add'l Pot Water Con Fee
Reel Water Con Fee
$19979 Meter Size
$0 00 Add'l Reel Water Con Fee
$12986 Meter Fee
$0 00 SDCWA Fee
$0 00 CFD Payoff Fee
$221 PFF (3105540)
$0 00 PFF (4305540)
$000 License Tax (3104193)
$000 License Tax (4304193)
$000 Traffic Impact Fee (3105541)
$0 00 Traffic Impact Fee (4305541)
$0 00 Sidewalk Fee
$0 00 PLUMBING TOTAL
$0 00 ELECTRICAL TOTAL
$0 00 MECHANICAL TOTAL
$0 00 Housing Impact Fee
$0 00 Housing InLieu Fee
$0 00 Housing Credit Fee
Master Drainage Fee
$0 00 Sewer Fee
$0 00 Additional Fees
TOTAL PERMIT FEES
$000
$000
$000
$000
$000
$000
$000
$000
$000
$000
$000
$000
$2000
$000
$000
$000
$000
$000
$000
$000
$351 86
Total Fees $351 86 Total Payments To Date $351 86 Balance Due.$000
BULLDING PLANS
__^/_ IN STORAGE
ATTACHED
Inspector I7K FINAL APPROVAL
Date Clearance
NOTICE Please take NOTICE that approval of your project includes the Imposition ojfees, dedications reservations or other exactions hereafter collectively
referred to as 'fees/exactions ' You have 90 days from the date this permit was issued to protest imposition of these fees/exactions If you protest them, you must
follow the protest procedures set forth in Government Code Section 66020(a) and file the protest and any other required information with the City Manager for
processing in accordance with Carlsbad Municipal Code Section 3 32 030 Failure to timely follow that procedure will bar any subsequent legal action to attack,
review set aside void or annul their imposition
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity
changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project NOR DOES IT APPLY to any
fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired
City of Carlsbad
1635 Faraday Ave , Carlsbad, CA 92008
760-602-2717 / 2718 / 2719
Fax 760-602-8558
Building Permit Application
Plan Check No.•l&"7
Est. Value
Plan Ck. Deposit
Date n
CT/PROJECT #LOT ft PHASE # OF UNITS ft BEDROOMS
SUITE#/SPACE#/UNIT#
# BATHROOMS TENANT BUSINESS NAME
SPRINKLERS~f
S D NOV
(Sec 70315 Business and Professions Code Any City or County which requires a permit to construct, alter improve demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is
licensed pursuant to the provisions of the Contractor s License Law {Chapter 9 commending with Section 7000 of Division 3 of the Business and Professions Code} or that he is exempt therefrom and the basis for the alleged exemption Any violation ofSection 70315 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars {$500})
Workers' Compensation Declaration / hereby affirm under penalty of perjury one of the following declarations
I have and will maintain a certificate of consent to self insure for workers' compensation as provided by Section 3700 of the Labor Code for the performance of the work for which this permit is issued
I have and will maintain workers' compensation as required by Section 3700 of the Labor Code for the performance of the work for which this permit is issued My workers' compensation insurance carrier and policy '
number are Insurance Co _ Policy No _ Expiration Date _
• This section need not be completed if the permit is for one hundred dollars ($100) or less
J Certificate of Exemption I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of
\ California WARNING Failure to secure workers' compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars (&100.000), in
\ addition to the cost of compensation, damages as provided for in Section 3706 of the Labor code, interest and attorney's fees <
CONTRACTOR SIGNATURE DATE
,;/•.;<*:
/ hereby affirm that I am exempt from Contractor s License Law for the following reason
O I as owner of the property or my employees with wages as their sole compensation will do the work and the structure is not intended or offered for sale (Sec 7044 Business and Professions Code The Contractor s
License Law does not apply to an owner of property who builds or improves thereon and who does such work himself or through his own employees, provided that such improvements are not intended or offered for
sale If however the building or improvement is sold within one year of completion the owner builder will have the burden of proving that he did not build or improve for the purpose of sale)
jtr I as owner of the property am exclusively contracting with licensed contractors to construct the project (Sec 7044, Business and Professions Code The Contractor s License Law does not apply to an owner of
property who builds or improves thereon and contracts for such projects with contractor(s) licensed pursuant to the Contractor s License Law)
: D I am exempt under Section....Business and Professions Code for this reason
\|
1 I personally plan to provide the major labor and materials for construction of the proposed property improvement n Yes D No
2 I (have / have not) signed an application for a building permit for the proposed work
3 I have contracted with the following person (firm) to provide the proposed construction (include name address / phone / contractors license number)
4 I plan to provide portions of the work but I have hired the following person to coordinate supervise and provide the major work (include name / address /phone / contractors' license number)
5 I will provide some of the work but I have contracted (hired) the following persons to provide the work indicated (include name / address /phone / type of work)
>£fpROPERTY OWNER SIGNATURE DATE
Is the applicant or future building occupant required to submit a business plan acutely hazardous materials registration form or risk management and prevention program under Sections 25505,25533 or 25534 of the
Presley Tanner Hazardous Substance Account Act' DYes D No
Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district' n Yes Q No
Is the facility to be constructed within 1 000 feet of the outer boundary of a school site' D Yes D No
IF ANY OF THE ANSWERS ARE YES,
EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT
joffaj^g ^ ^ v:,;;!.-,-
I hereby affirm that there is a construction lending agency for the performance of the work this permit is issued (Sec 3097 (i) Civil Code)
Lender's Name Lender's Address
• IrerofythatlhavereadmeapplirauonandstateuiattheabovemfonriatonB I agree tocomplywithallCityordinancesand State lawsrelatingtobuildingconstrurjdon
J hereby authonze representative of the City of Carlsbad to enter upon the above mentioned property for inspection purposes I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD
AGAINST ALL LIABILITIES, JUDGMENTS COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT
OSHA An OSHA permit is required for excavations over 5 0' deep and demolition or construction ofslructures over 3 stones in height
| EXPIRATION Every permit issued by the Building Official under the provisions of this Cdbe sha Wireb^fhitatjon and become null and void if the building or work authonzed by such permit is not commenced within
i 180 days from ffie date of such permit or ifJieJiiJdffl^QLMirJi^uSiorEed by sudj pe^nrj is su?fflnde/ror abandoned at any time after the work is commenced for a penod of 180 days (Section 106 4 4 Uniform Building Code)
^APPLICANT'S SIGNATURE * /^\S^&*2fr£/ J/ fat ^^ DATE
City of Carlsbad Bldg Inspection Request
For 03/31/2009
Permit* CB071875
Title MALLOY RESIDENCE
Description 181 SF ADDITION, ENTRY & DINING ROOM
Inspector Assignment PY
2808 CACATUA ST
Lot
Type RESDNTL
Job Address
Suite
Location
APPLICANT RDA DESIGNS
Owner MALLOY BRIAN&MARY
Remarks
Sub Type RAD
Phone 7604975271
Inspector
Total Time
CD Description
19 Final Structural
29 Final Plumbing
39 Final Electrical
49 Final Mechanical
Requested By BRIAN
Entered By KATHY
Act Comments
Comments/Notices/Holds
Date
02/26/2009
02/12/2009
05/01/2008
04/24/2008
04/22/2008
04/22/2008
04/16/2008
04/16/2008
03/26/2008
10/03/2007
10/03/2007
Associated PCRs/CVs Original PC#
CV020271 CLOSED BIZ LICENSE - MONK,
CV060413 CLOSED Z- HOME BASED HI// NO LICENSE,
PCR08038 ISSUED MALLOY RES-FRAMING REVISIONS, TO WALL/ROOF
Inspection History
Description
89 Final Combo
89 Final Combo
17 Interior Lath/Drywall
16 Insulation
23 Gas/Test/Repairs
31 Underground/Conduit-Wiring
13 Shear Panels/HD's
14 Frame/Steel/Bolting/Welding
14 Frame/Steel/Boltmg/Welding
62 Steel/Bond Beam
66 Grout
Act
CO
NR
AP
AP
AP
WC
AP
AP
CO
WC
AP
Insp Comments
PY SMOKE ALARMS @ ALL BEDROOMS
PY
PY
JM
JM FIREPLACE
JM
PY
PY
PY
PY
PY
NEED SHEAR INSPECTION
EsGil Corporation
In <Partnersnip witfi government for <3uihfing Safety
DATE August 20, 2007 a APPLICANT
JURISDICTION City of Carlsbad a PLAN REVIEWER
a FILE
PLAN CHECK NO CB071875 SET II
PROJECT ADDRESS 2808 Cacatua St.
PROJECT NAME Addition for the Malloy Residence
XI The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes
The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff
The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck
The check list transmitted herewith is for your information The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck
The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person
The applicant's copy of the check list has been sent to
X3 Esgil Corporation staff did not advise the applicant that the plan check has been completed
_J Esgil Corporation staff did advise the applicant that the plan check has been completed
Person contacted Telephone #
Date contacted (by ) Fax #
Mail Telephone Fax In Person
X] REMARKS Please have the designer sign all sheets of the plans ^
By Steve Sanders Enclosures
Esgil Corporation
D GA D MB D EJ D PC 8/13/07
9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 *• (858)560-1468 4 Fax (858) 560-1576
EsGii Corporation
In Partners/tip with government for Quitting Safety
DATE July 23, 20O7 O-AREUCANT
JURISDICTION City of Carlsbad a PLAN REVIEWER
a FILE
PLAN CHECK NO CBO71875 SET I
PROJECT ADDRESS 2808 Cacatua St.
PROJECT NAME Addition for the Malloy Residence
The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes
The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff
The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck
2S| The check list transmitted herewith is for your information The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck
The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person
1X1 The applicant's copy of the check list has been sent to
Ron Alvarez
PO Box 40 Carlsbad, CA 92018
Esgil Corporation staff did not advise the applicant that the plan check has been completed
2<J Esgil Corporation staff did advise the applicant that the plan check has been completed
Person contacted Ron Alvarez (\f M) Telephone # (760) 729-8099
Date contacted 7/21^/07 (by «^_) Fax # None Provided
Mail ^xTelephone^/ Fax In Person
REMARKS
By Steve Sanders Enclosures
Esgil Corporation
D GA D MB D EJ D PC 7/16/07
9320 Chesapeake Drive, Suite 208 ^ San Diego, California 92123 * (858)560-1468 ^ Fax (858) 560-1576
City of Carlsbad CB071875
July 23, 2OO7
PLAN REVIEW CORRECTION LIST
SINGLE FAMILY DWELLINGS AND DUPLEXES
PLAN CHECK NO CB071875 JURISDICTION City of Carlsbad
PROJECT ADDRESS 2808 Cacatua St.
FLOOR AREA Addition 181 sq ft
REMARKS
DATE PLANS RECEIVED BY
JURISDICTION 7/13/07
DATE INITIAL PLAN REVIEW
COMPLETED July 23, 2007
STORIES 2
HEIGHT 24'-6" (existing)
DATE PLANS RECEIVED BY
ESGIL CORPORATION 7/16/07
PLAN REVIEWER Steve Sanders
FOREWORD (PLEASE READ):
This plan review is limited to the technical requirements contained in the Uniform Building Code,
Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws
regulating energy conservation, noise attenuation and access for the disabled This plan review
is based on regulations enforced by the Building Department You may have other corrections
based on laws and ordinance by the Planning Department, Engineering Department, Fire
Department or other departments Clearance from those departments may be required prior to
the issuance of a building permit
Present California law mandates that residential construction comply with the 2001 edition of
the California Building Code (Title 24), which adopts the following model codes 1997 UBC,
2000 UPC, 2000 UMC and 2002 NEC
The above regulations apply to residential construction, regardless of the code editions adopted
by ordinance
The following items listed need clarification, modification or change All items must be satisfied
before the plans will be in conformance with the cited codes and regulations Per Sec 106 4 3,
1997 Uniform Building Code, the approval of the plans does not permit the violation of any
state, county or city law
To speed up the recheck process, please note on this list (or a copy) where each
correction item has been addressed, i.e.. plan sheet number, specification section, etc.
Be sure to enclose the marked up list when you submit the revised plans.
City of Carlsbad CBO71875
July 23, 20O7
Please make all corrections, as requested in the correction list Submit three new
complete sets of plans for commercial/industrial projects (two sets of plans for
residential projects) For expeditious processing, corrected sets can be submitted
in one of two ways
1 Deliver all corrected sets of plans and calculations/reports directly to the City of
Carlsbad Building Department, 1635 Faraday Ave , Carlsbad, CA 92008, (760)
602-2700 The City will route the plans to EsGil Corporation and the Carlsbad
Planning, Engineering and Fire Departments
2 Bring one corrected set of plans and calculations/reports to EsGil Corporation,
9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468
Deliver all remaining sets of plans and calculations/reports directly to the City of
Carlsbad Building Department for routing to their Planning, Engineering and Fire
Departments
NOTE Plans that are submitted directly to EsGil Corporation only will not be
reviewed by the City Planning, Engineering and Fire Departments until review by
EsGil Corporation is complete
1 All sheets of plans must be signed by the person responsible for their
preparation (California Business and Professions Code)
2 Provide a statement on the Title Sheet of the plans stating that this project shall
comply with the 2001 editions of the California Building/Plumbing/Mechanical
Codes and the 2004 edition of the California Electrical Code, which adopt the
1997 UBC, 2000 UMC, 2000 UPC and the 2002 NEC Please expand the
Codes shown on sheet A-1 to reference these codes.
3 Window area must be at least 1 /10 of the floor area
Openable window area in habitable rooms must be 1/20 of the floor area
Section 1203 3 Please show that the existing living room combined with
the proposed retreat meet the above requirements for natural light and
ventilation.
4 Note on plans that surface water will dram away from building and show drainage
pattern Section 1804 7
City of Carlsbad CBO71875
July 23, 2007
5 Specify on the plans the following information for the fireplace(s), per Section
10633
a) Manufacturer's name
b) Model name/number
c) ICBO approval number, or equal
d) Show height of chimney above roof per ICBO approval or UBC Table
31-B
e) Note on the plans that approved spark arresters shall be installed on all
chimneys UBC, Section 3102 3 8
Please clarify if the proposed fireplace is a manufactured or masonry
fireplace. If the fireplace is manufactured, please provide the above
information on the plans. If it is a masonry fireplace please provide on the
plans construction details.
6 The regulations require a properly completed and properly signed Form CF-1R
(4 pages) to be either imprinted on the plans, taped to the plans or "sticky
backed" on the plans, to allow the building inspector to readily compare the
actual construction with the requirements of the approved energy design
7 Show on the plans compliance with the residential energy lighting requirements
(Mandatory requirement)
a) Outdoor lighting fixtures are required to be high efficacy or controlled by a
combination photocontrol/motion sensor
To speed up the review process, note on this list (or a copy) where each
correction item has been addressed, i e , plan sheet, note or detail number,
calculation page, etc
Please indicate here if any changes have been made to the plans that are not a
result of corrections from this list If there are other changes, please briefly
describe them and where they are located in the plans
« Have changes been made to the plans not resulting from this
correction list? Please indicate
Yes Q No Q
The jurisdiction has contracted with Esgil Corporation located at 9320
Chesapeake Drive, Suite 208, San Diego, California 92123, telephone number of
858/560-1468, to perform the plan review for your project If you have any
questions regarding these plan review items, please contact Steve Sanders at
Esgil Corporation Thank you
City of Carlsbad CBO71875
July 23, 2007
VALUATION AND PLAN CHECK FEE
JURISDICTION City of Carlsbad
PREPARED BY Steve Sanders
BUILDING ADDRESS 2808 Cacatua St.
PLAN CHECK NO CB071875
DATE July 23, 2007
BUILDING OCCUPANCY R-3 TYPE OF CONSTRUCTION VN
BUILDING
PORTION
Addition
Air Conditioning
Fire Sprinklers
TOTAL VALUE
Jurisdiction Code
AREA
(Sq Ft)
181
cb
Valuation
Multiplier
121 94
By Ordinance
Reg
Mod
VALUE ($)
22,071
22,071
$19979
Plan Check Fee by Ordinance
Type of Review
_T~l Repetitive FeeRepeatsI
0 Complete Review
D Other
r—i Hourly
Structural Only
Hour
Esgil Plan Review Fee
Comments
$12986
$111 88
Sheet 1 of 1
macvalue doc
PLANNING/ENGINEERING APPROVALS
PERMIT NUMBER CB
ADDRESS
DATE
RESIDENTIAL TENANT IMPROVEMENT
RESIDENTIAL ADDITIO
« $10,000.00)
OTHER
PLAZA CAMINO REAL
CARLSBAD COMPANY STORES
VILLAGE FAIRE
COMPLETE OFFICE BUILDING
PLANNER
ENGINEER
DATE
DATE
Docs/Misforms/Plannmg Engineering Approvals
<U 0) <U
§ § §
Ci
£
o oc c
Q_ Q_ o.
PLANNING DEPARTMENT
BUILDING PLAN CHECK REVIEW CHECKLIST
Plan Check No CB071875
Planner
APN 215-370-02-00
Address 2808 Cacatua St
Deborah Milam Phone (760)602-4619
Type of Project & Use
Zoning K" I General Plan fUj^
CFD (in/out) #_Date of participation
Net Project Density DU/AC
. Facilities Management Zone 6_
Remaining net dev acres
Circle One
(For non-residential development Type of land used created by this
permit )
Legend Item Complete
Environmental Review Required
DATE OF COMPLETION
Item Incomplete - Needs your action
YES NO A TYPE
Compliance with conditions of approval9 If not, state conditions which require action
Conditions of Approval
Discretionary Action Required.
APPROVAL/RESO NO
PROJECT NO
YES NO TYPE
DATE
OTHER RELATED CASES
Compliance with conditions or approval9 If not, state conditions which require action
Conditions of Approval
D
izfn n
Coastal Zone Assessment/Compliance
Project site located in Coastal Zone7 YES_
CA Coastal Commission Authority9 YES_NO
If California Coastal Commission Authority Contact them at - 7575 Metropolitan Drive, Suite 103,
San Diego CA 92108-4402, (619) 767-2370
Determine status (Coastal Permit Required or Exempt)
Habitat Management Plan
Data Entry Completed9 YES NO
If property has Habitat Type identified in Table 11 of HMP, complete HMP Permit application and
assess fees in Permits Plus
(A/P/Ds, Activity Maintenance, enter CB#, toolbar, Screens, HMP Fees, Enter Acres of Habitat Type
impacted/taken, UPDATE')
D D Inclusionary Housing Fee required YES NO ¥~
(Effective date of Inclusionary Housing Ordinance - May 21, 1993 )
Data Entry Completed9 YES NO
(A/P/Ds', Activity Maintenance, enter CB#, toolbar, Screens, Housing Fees, Construct Housing Y/N,
Enter Fee, UPDATE')
H \ADMIN\COUNTER\BldgPlnchkRevChklst Rev 3/06
Q
Site Plan
Provide a fully dimensional site plan drawn to scale Show North arrow, property lines, easements,
existing and proposed structures, streets, existing street improvements, right-of-way width,
dimensional setbacks and existing topographical lines (including all side and rear yard slopes)
Provide legal description of property and assessor's parcel number
Policy 44 - Neighborhood Architectural Design Guidelines
1 Applicability YES _ NO_
2 Project complies YES _ NO_
n
n
n n
n n
n n
Zoning
1 Setbacks
Front
Interior Side
Street Side
Rear
Top of slope
2 Accessory structure setbacks
Front
Interior Side
Street Side
Rear
Structure separation
3 Lot Coverage
Required £~V
Required £"'
Required 5'
Required /O'
Required
:ks AJft
Required
Required
Required
Required
Required
Required <C ^
Shown
Shown
Shown
Shown
Shown
Shown
Shown
Shown
Shown
Shown
fO'/« Shown
Ib H
7' 7 *
-?'?"
IS' I"
[H'/o
4 Height Required
Spaces Required
Shown
Shown
/Oft-
5 Parking
(breakdown by uses for commercial and industrial projects required)
Residential Guest Spaces Required Shown
Additional Comments
OK TO ISSUE AND ENTERED APPROVAL INTO COMPUTER DATE
H \ADMIN\COUNTER\BldgPlnchkRevChklst Rev 3/06
CERTIFICATE OF COMPLIANCE: RESIDENTIAL (Page 1 of 5)CF-1R
Project •V Building Permit #
Plan Check / Date
Documentation Author
Compliance Method (Prescriptive)
Telephone
*Field Check / Date
Climate Zone
^Enforcement Agency Use Only
Alternative Component Package Method" (check one)D (Alternative)
Package C and Package D choices require HERS rater field verification and/or diagnostic testing (see CF-1R page 3)
For Package D Alternative see Appendix B Table 151 -C Footnotes 8-14 in the Residential Compliance Manual (RCM)
GENERAL INFORMATION ,
Total Conditioned Floor Area (CFA) /& I ft2
Average Ceiling Height
Check Applicable Boxes
ft
Building Type- (check one or more) Single Family Multifamily /\ Addition Alteration
(If adding fenestration fill-out WS-4R, Fenestration Maximum Allowed Area Worksheet and see Section 832
for Additions and 83.3 for Alterations in the RCM )
Maximum Allowed Total Fenestration Area
Maximum Allowed West Facing Fenestration Area
Number of Stories / Number of Duelling Units
Floor Construction Type SI
Front Orientation /&?£? North /
ft2 (from WS-4R)
from True North and circle one)
D RADIANT BARRIER (check box if required in climate zones 2.4.
'(circle one or both)
West All Orientations (input front orientation in degrees
OPAQUE SURFACES INCLUDING OPAQUE DOORS
Component
Type (Wall,
Roof, Floor,
Slab Edge,
Doors)pzase-
WAf^S-
C&/UM&
Frame
Type
(Wood or
Metal)
W&&*
wz&e?
we&P*
Cavity
Insulation
R-Value
£-/<?
&-/£>
/Z~3&
Continuous
Insulation
R-Value
Assembly U-
factor (for wood,
metal frame and
mass
assemblies) '
Joint
Appendix
IV
Reference
RoofRadiant
Barrier
Installed2
Yes or No
Location
Comments
(attic, garage,
typical, etc.)
&&..S/&-
—*•
Ar77<2*
1) See Joint Appendix IV in Section IV 2, IV 3, and IV.4, which is the basis for the U-factor criterion U-factors can not exceed
prescriptive value to show equivalence to R-values
2) This column is for the Inspector to verify installation of roof radiant barrier
Residential Compliance Forms December 2005
CERTIFICATE OF COMPLIANCE: RESIDENTIAL (Page 2 of 5)CF-1R
Project Title Date
FENESJRATION PRODUCTS - U-FACTOR AND SHGC
S CETpENESTRATlON MAXIMUM ALLOWED AREA WORKSHEET WS-4R - must be included for New
Construction, Additions, and Alterations
Fenestration
#/Type/Pos (Front,
Left, Rear, Right,
Skylight)
/^7C^?V7"~
Orien-
tation,
N, S, E, W1
-^
Area
(ft2)
<&£
U-factor2
.-^
U-factor
Source3 SHGC4
.<he?
SHGC
Source5
Exterior
Shading/Overhangs6 7
v'boxifWS-SRis
included
D
O
D
D
D
D
D
1) Skylights are now included in West-facing fenestration area if the skylights are tilted to the west or tilted in any direction when
the pitch is less than 112 See §151(f)3C and in Section 323 of the Residential Manual
2) Enter values in this column from either NFRC Certified Label or from Standards Default Table 116-A
3) Indicate source either from NFRC or Table 116-A,
4) Enter values in this column from NFRC or from Standards Default Table 116B or adjusted SHGC from WS-3R
5) Indicate source either from NFRC, Table 116B or WS-3R
6) Shading Devices are defined in Table 3-3 in the Residential Manual and see WS-3R to calculate Exterior Shading devices.
7) See Section 3 2 4 in the Residential Manual
HVAC SYSTEMS
Heating Equipment
Type and Capacity
(furnace, heat pump, boiler etc )
>=i^C^?^^.
(&X/&r7A4Sr?
Minimum
Efficiency
(AFUEorHSPF)
Distribution
Type and Location
(ducts, attic, etc )
Duct or Piping
R-Value
Thermostat
Type
Configuration
(split or package)
Cooling Equipment
Type and Capacity
(A/C, heat pump, evap
cooling)
/V/S¥
Minimum
Efficiency
(SEER or
HER)
Distribution
Type and Location
(duels, attic etc )
Duct or Piping
R-Value
Thermostat
Type
Configuration
(split or package)
Residential Compliance Forms December 2005
CERTIFICATE OF COMPLIANCE: RESIDENTIAL (Page 3 of 5) CF-1R
Project Title Date
SEALED DUCTS and TXVs (or Alternative Measures'}
A signed CF-4R Form must be provided to the building department for each home for which the following are required
D Sealed Ducts (all climate zones) (Installer testing and certification and HERS rater field verification required)
D TXVs, readily accessible (climate zones 2 and 8-15 only)
(Installer testing and certification and HERS Rater field verification required)
D Refrigerant Charge (climate zones 2 ^nd 8-15 only) (Installer testing and certification and HERS Rater field
verification required)
OR
Alternative to Sealed Ducts and Refrigerant Charge /TXVs (See Package D Alternative Package Features for
Project Climate Zone in the RM Appendix B Table 151-C, Footnotes 7-14
OR
D No ducts installed.
New ducts from existing space conditioning equipment, not exceeding 40ft in length
For additions and alterations, duct systems that are not documented to have been previously sealed as confirmed
through field verification and diagnostic testing in accordance with procedures in the Residential ACM Manual
Duct systems with more than 40 linear feet in unconditioned spaces shall meet the requirements of Section 150(m)
and duct insulation requirements of Package D ______
WATER HEATING SYSTEMS
Check box if system meets criteria of a "Standard" system Standard system is one gas-fired water heater per dwelling
unit If the water heater is a storage type, 50 gallons is the maximum capacity and recirculation system is not allowed
D Check box when using Preapproved Alternative Water Heating table, Table 5-4 in Chapter 5 in the Residential
Manual No water heating calculations are required, and the system complies automatically
D
Check box if system does not meet criteria of "Standard" system, and does not comply with the Preapproved
Alternative Water Heating table In this case, the Performance Method must be used and must be included in the
submittal.
D | Check box to verify that a time control is required for a recirculating system pump for a system serving multiple units
Systems serving single dwelling units (See KM Table 5-4, Alternative Water Heating Systems for recirculation requirements)
Water Heater
Type/Fuel Type
£%?f7* (&A&)
f&X/'&r/H&r ~)
Distribution
Type
Number
in System
Rated
Input1
(kWor
Btu/hr)
Tank
Capacity
(gallons)
&£?
Energy
Factor' or
Thermal
Efficiency
Standby'
Loss (%)
Tank
External
Insulation
R-Value
/£"/%-
System serving multiple dwelling units (See Residential Manual Section 533)
Water Heater
Type
Distribution
Type
Number
in System
Rated
Input'
(kWor
Btu/hr)
Tank
Capacity
(gallons)
Energy
Factor1 or
Thermal
Efficiency
Standby1
Loss (%)
Tank
External
Insulation
R-Value
1) For small gas storage water heaters (rated inputs of less than or equal to 75 000 Btu/hr) electric resistance, and heat pump water heaters, list
Energy Factor For large gas storage water heaters (rated input of greater than 75 000 Btu/hr), list Rated Input, Recovery Efficiency. Thermal
Efficiency and Standby Loss For instantaneous gas water heaters list Rated Input and Thermal Efficiencies
Pipe Insulation (kitchen lines > 3/4 inches) All hot water pipes from the heating source to the kitchen fixtures
that are % inches or greater in diameter shall be thermally insulated as specified by Section 150 (j) 2 A or 150 0) 2 B
Residential Compliance Forms December 2005
CERTIFICATE OF COMPLIANCE: RESIDENTIAL (Page 5 of 5) CF-1R
ProjK1T""
Special Remarks
COMPLIANCE STATEMENT
This certificate of compliance lists the building features and specifications needed to comply with Title 24,
Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them This
certificate has been signed by the individual with overall design responsibility The undersigned recognizes that
compliance using duct design, duct sealing, verification of refrigerant charge and TXVs, insulation installation
quality, and building envelope sealing require installer testing and certification and field verification by an
approved HERS rater.
Designer or Owner (per Business and Professions Code) Documentation Author
Title/Firm
Address _
?£?. &&X -ft?
Telephone/^, )
License #License # (if applicable)
(signature)(date) (signature)(date)
Enforcement Agency
Name
Title
Agency
Telephone
(signature / stamp)(date)
Comments
Residential Compliance Forms December 2005
MANDATORY MEASURES SUMMARY: RESIDENTIAL (Paee i of 2) MF-1R
Project Title
Note Low-rise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used More
stringent compliance requirements from the Certificate of Compliance supersede the items marked with an asterisk (*) below When this
checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component
performance specifications for the mandatorj measures whether they are shown elsewhere in the documents or on this checklist onl>
Instructions Check or initial applicable boxes or check NA if not applicable and included with the permit application
documentation -
DESCRIPTION
Building Envelope Measures:
* §)50(a) Minimum R-19 in wood frame ceiling insulation or equivalent U-factor in metal frame ceiling
§150fb1 Loose fill insulation manufacturer's labeled R- Value
* f 150(c) Minimum R-13 wall insulation in wood framed walls or equivalent U-factor in metal frame walls (does not apply
to exterior mass walls)
* §150(d) Minimum R-13 raised floor insulation in framed floors or equivalent U-factor
NA
S
D
*(
D
D
Designer
' f
, rf
n .
*,&
Enforce
-meitt•/
n
n
n
a
§150(e) Installation of Fireplaces, Decorative Gas Appliances and Gas Logs
1 Masonry and factory-built fireplaces have ^
a. closeable metal or glass door covering the entire opening of the firebox
b outside air intake with damper and control, flue damper and control
2 No continuous burning gas pilot lights allowed.
§150(f) Air retarding wrap installed to comply with §151 meets requirements specified in the ACM Residential Manual
§ I 50(g) Vapor barriers mandatory in Cl imate Zones 1 4 and 1 6 only
§150(1) Slab edge insulation - water absorption rate for the insulation material alone without facings no greater than 0 3%
water vapor permeance rate no greater than 2 0 perm/inch
§118 Insulation specified or installed meets insulation installation quality standards Indicate type and include CF-6R
Form.
BT
<
*&
tf
sT
, D
D
, D
I D
, n
D
D
D
D
a
a
a
n
a
§!16-§117 Fenestration Products, Exterior Doors, and Infiltration/Exfiltration Controls ^
1 Doors and windows between conditioned and unconditioned spaces designed to limit air leakage
2 Fenestration products (except field-fabricated) have label with certified U-factor, certified Solar Heat Gam
Coefficient (SHGC), and infiltration certification
3 Exterior doors and windows weather-stripped, all joints and penetrations caulked and sealed
D
D
D
Space Conditioning, Water Heating and Plumbing System Measures:
§ 1 1 0-§ 1 1 3 HVAC equipment, water heaters, showerheads and faucets certified by the Energy Commission
§ 15000 Heating and/or cooling loads calculated in accordance with ASHRAE SMACNAorACCA
§150(i) Setback thermostat on all applicable heating and/or cooling systems
<
<
Ef
HC,
*,
ET
a
D
a
»
n
. D
n
a
a
D
§150(j) Water system pipe and tank insulation and cooling systems line insulation. f
1 Storage gas water heaters rated with an Energy Factor less than 0 58 must be externally wrapped with insulation
having an installed thermal resistance of R-12 or greater
2 Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-l 2 external insulation or
R- 1 6 internal insulation and indicated on the exterior of the tank showing the R-value.
st
D
3 The following piping is insulated according to Table 150-A/B or Equation 150-A Insulation Thickness m
1 First 5 feet of hot and cold water pipes closest to water heater tank, non-recirculatmg systems, and entire length
of recirculatmg sections of hot water pipes shall be insulated to Table 150B
2 Cooling system piping (suction, chilled water, or bnne lines), piping insulated between heating source and
indirect hot water tank shall be insulated to Table 1 50-B and Equation 1 50-A
4 Steam bydromc heaung systems or hot water s\stems>15psi, meet requirements ofTable 123-A
tf
&
&
n/a
a
a
D
a
a
a
a
Residential Compliance Forms December 2005
MANDATORY MEASURES SUMMARY: RESIDENTIAL (Page 2 of 2) MF-1R
DESCRIPTION
Space Conditioning, Water Heating and Plumbing System Measures: (continued)
5 Insulation must be protected from damage including that due to sunlight, moisture equipment maintenance, and wind
6 Insulation for chilled water piping and refrigerant suction piping includes a vapor reiardant or is enclosed entirely m
conditioned space
7 Solar water-heating systems/collectors are certified by the Solar Rating and Certification Corporation
NA
V
D
^d
Designer
' >>
B'
0
n
Enforce-
ment
•n
D
n
• §150(m) Ducts and Fans
1 AJlductsaru)p!enurr^instaJled,sealedand msulatedtomeettherequirernentoftheCMCSectionseOl, 602,603.604,605
and Standard 6-5, supply-air and return-air ducts and plenums are insulated to a minimum installed level of R-4.2 or enclosed
entirely in conditioned space Openings shall be sealed with mastic tape or other duct-closure system that meets the
applicable requirements of UL 181, UL 1 81 A, or UL 1 81B or aerosol sealant that meets the requirements of UL 723 If
mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used.
2 Building cavities support platforms for air handlers and plenums defined or constructed with materials other than
sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air Building cavities and
support platforms may contain ducts Ducts installed in cavities and support platforms shall not be compressed to cause
reductions in the cross-sectional area of the ducts
3 Joints and seams of duct systems and their components shall not be sealed with cloth back rubber adhesive duct tapes
unless such tape is used in combination with mastic and draw bands
4 Exhaust fan systems have back draft or automatic dampers
5 Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated
dampers
6 Protection of Insulation Insulation shall be protected from damage including that due to sunlight, moisture equipment
maintenance, and wind Cellular foam insulation shall be protected as above or painted with a coating that is water
retardant and provides shielding from solar radiation that can cause degradation of the material
7 Flexible ducts cannot have porous inner cores
/
/
/
*,B1.s/1
J
/
&
n
n
D
D
n
n
D
n
n
n
D
n
n
D
§114 Pool and Spa Heating Systems and Equipment t
\ A thermal efficiency that complies with the Appliance Efficiency Regulations, on-off switch mounted outside of the
heater, weatherproof operating instructions, no electric resistance heating and no pilot light.
2 System is installed with
a. at least 36" of pipe between filter and heater for future solar heating
b cover for outdoor pools or outdoor spas
3 Pool system has directional inlets and a circulation pump time switch
§115 Gas fired fan-type central furnaces, pool heaters, spa heaters or household cooking appliances nave no continuously
burning pilot light (Exception Non-electncal cooking appliances with pilot < 150 Btu/hr)
§ 1 1 8(1) Cool Roof material meets specified criteria
&n n
A
&,
*tsr
*,5T
n
Dn
n
D
n
D
D
n
n
Residential Lighting Measures:
§150(k)l HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID contain only high efficacy lamps as
outlined in Table 1 50-C, and do not contain a medium screw base socket (E24/E26) Ballast for lamps 1 3 watts or greater
are electronic and have an output frequency no less than 20 kHz
§1 50(k)I HIGH EFFICACY LUMINAIRES - OUTDOOR HID contain only high efficacy lamps as outlined in Table
1 50-C, lummaire has factory installed HID ballast
§150(k)2 Permanently installed luminaires in kitchens shall be high efficacy lummaires Up to 50 percent of the wattage as
determined m § 130 (c) of permanently installed lummaires in kitchens may be in luminaires that are not high efficacy
luminaires, provided that these luminaires are controlled by switches separate from those controlling the high efficacy
luminaires
§150(k)3 Permanently installed luminaires in bathrooms, garages laundry rooms and utility rooms shall be high efficacy
luminaires OR are controlled by an occupant sensor(s) certified to comply with Section 1 19(d) that does not turn on
automatically or have an always on option
§ 1 50004 Permanently installed luminaires located other than m kitchens, bathrooms, garages, laundry rooms, and utility
rooms shall be high efficacy lummaires (except closets less than 70ft2) OR are controlled by a dimmer switch OR are
controlled by an occupant sensor that complies with Section 1 19(d) that does not turn on automatically or have an always
on option
§150(k)5 Lummaires that are recessed into insulated ceilings are approved for zero clearance insulation cover (1C) and are
certified airtight to ASTM E283 and labeled as air tight (AT) to less than 2 0 CFM at 75 Pascals
§1 50(k)6 Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on
the same lot shall be high efficacy luminaires (not including lighting around swimming pools/water features or other
Article 680 locations) OR are controlled bv occupant sensors with integral photo control certified to comply with Section
119(d)
§ 1 50(k)7 Lighting for parking lots for 8 or more vehicles shall have lighting that complies with Sec 1 30, 1 32, and 147
Lighting for parking garages for & or more vehicles shall have lighting that complies with Sec 130, 131 , and 146
§150008 Permanently installed lighting in the enclosed, non-dwelling spaces of low-rise residential buildings with four or
more dwelling units shall be high efficacv luminaires OR are controlled by occupant sensorfs) certified to comply with
Section 119(d)
D
j
sf
D
E/
D
D
J/
ti
^
. «
n
J
D
J
Ef
D
D
D
D
n
n
D
a
D
n
n
n
Residential Compliance Forms December 2005
FENESTRATION - MAXIMUM ALLOWED AREA WORKSHEET WS-4R
Project Title
FENESTRATION PRODUCTS - NEW CONSTRUCTION- NEW BUILDINGS
Use this table for new building construction to account for total building % of fenestration
A
#AType/Pos
(Front, Left,
Rear, Right,
- Skylight)
B
Orientation
North
South
East
West
Totals
C
Total
Fenestration,
West Facing
Areafft2)
D
Total Fenestration for
N, S, E Orientations
-—Area (ft2)
E
CFA (ft2) -
F
Total Percent of
West Facing
Fenestration1
(C/E)xlOO%~-
G
Total % of
Fenestration2
Including West
-(D/E)xlOO% + F
1) If west facing area exceeds 5% of CFA in climate zones 2,4, and 7-15, the performance approach must be used.
2) If total percent of fenestration exceeds 20% including West facing orientations then performance approach must be used West facing area includes
skylights tilted to the west or tilted in any direction when the pitch is less than 1 12 for Package D only
FENESTRATION PRODUCTS - NEW CONSTRUCTION- ADDITIONS
DLess than 100 ft2. D Less than or Equal to 1000 ft2. D Greater 1000 ft2
A
#/Type/Pos
(Front, Left,
Rear, Right,
Skylight)
f&f*/7~sasiAcz,
B
Orienta-
tion
North
South
East
West"
C
Proposed
Addition's
CFA1 2 3
D
Proposed
Addition's
Fenestration
Area (ft2)4
4&^
2&.*>
E
Fenestration
Area Removed to
make way for
Addition (ft2)2
&£?•Z~£?
F
Total Area
Added
Fenestration2
(D-E)
7&4&&
Total
G
Total % of West Facing
Fenestration2
(G/C) x 100%
H
Total % of
Fenestra-
tion2-3 4
(F/C) x 100%
1) Additions <100 sf are allowed to install up to 50ft2 of fenestration and are exempt from the 5% west facing and 20% maximum total area
limits and shall meet the U-factor and SHGC requirements of Package D See Table 8-2 in the Residential Manual Note Leave columns E, F,
G,H, and I blank
2) Additions <1,000 ft2, the maximum net allowed fenestration is 20% and may be increased additionally to by the amount of glazing removed in
the wall that separates the addition from the existing house However, the total West facing fenestration can not exceed 5% of the proposed
addition's CFA including skylights orientated in any direction and tilted with a pitch of < 1 12 Column G can not exceed 5% and Column H can
not exceed 20%
3) Additions > 1,000 ft2, must meet Package D requirements See Table 8-2 and Table 151-C in Appendix B of the RM or use Performance Approach
4) The 5%west orientation restrictions are only for Climate zones 2, 4, and 7-15, for Climate Zones 2,4 and 7-15 enter zero (0) in column E
FENESTRATION PRODUCTS: ALTERATIONS
Use this table for alterations to an existing building where fenestrations products (windows) are being removed and/or added
A
Existing
CFA
(ft2)
B
Existing
Orientation
North
South
East
West
Total
C
Existing
Area
(ft2)
D
Removed
Orientation
North
South
East
West
Total
E
Removed
Area
(02)
F
Proposed
Installed
Orientation
North
South
East
West
Total
G
Proposed
Installed
New Area
(02)
H
Total Net
Fenestration
(ft2)
(C-E+G)
I
Total % of
Fenestra-tion1 2
(H/A)xlOO%
Max of 20%
1) When 50 ft or more of fenestration area is added to an existing building, then the fenestration must meet the requirements of Package D
2) The area requirement for the total fenestration area for the whole building, including the added fenestration, must not exceed 20%.
Otherwise, the Performance Approach must be used See Section 8 3 3 in the RM for further details
Residential Compliance Forms December 2005
8troV)<<O LU Q°a>- to»fiz Q§Q° 3CM co b £LU Q L£'.. Q^n ,S§fe§1"S N.r\o:!W LUs55-8£orau.<ie*
u
0
«
0
to
r
0
U
IL
(§)
O
j
0
J
5&
r-
Q
0
0
I
li)
3
<
S
_o_8
04-15-2008
City of Carlsbad
1635 Faraday Av Carlsbad, CA 92008
Plan Check Revision Permit No PCR08038
Building Inspection Request Line (760) 602-2725
Job Address 2808 CACATUA ST CBAD
Permit Type PCR
Parcel No 2153700200 Lol#
Valuation $0 00 Construction Type
Reference* CB071875
Project Title MALLOY RES-FRAMING REVISIONS
TO WALL/ROOF
0
NEW
Applicant
RON ALVAREZ
P O BOX 40
CARLSBAD CA 92018
760 525 1659
Status
Applied
Entered By
Plan Approved
Issued
Inspect Area
Owner
MALLOY BRIAN&MARY
428 LAVENTURE
MT VERNON WA 98273
ISSUED
04/03/2008
LSM
04/15/2008
04/15/2008
Plan Check Revision Fee
Additional Fees
$12000
$000
Total Fees $120 00 Total Payments To Date $12000 Balance Due $000
Inspector
FINAL APPROVAL
Date Clearance
NOTICE Please take NOTICE that approval of your project includes the Imposition of fees, dedications, reservations, cr other exactions hereafter collectively
referred to as "fees/exactions" You have 90 days from the date this permit was issued to protest imposition of these feeb/exactions If you protest them, you must
follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required 'nformation with the City Manager for
processing in accordance with Carlsbad Municipal Code Section 3 32 030 Failure to timely follow that procedure will ba any subsequent legal action to attack,
review set aside, void, or annul their imposition
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity
changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project NOR DOES IT APPLY to any
fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired
City of Carlsbad
Building Department
Plan Check Revision No
Project Address
Contact
£^0%% Original Plan Check No
Date J
Fax
TLfLZT-
APN
Business at this address
General Scope of Work
Original plans prepared by an architect or engineer, revisions must be signed & stamped by that person
1 Elements revised
Plans Calculations Soils O Energy Other_
2
Describe revisions in detail
^tfr* ^-Z- f=#A*1*tf£>? A£%?t77&A^
WAt^/ /Z>f^ fT^diti M/ '£*7
/ *
3
List page(s) where
each revision is
shown
^-^L
-^-c£
4
List revised sheets
that replace
existing sheets
<^^ -*2/i?J
^-^
5 Does this revision, many way, alter the exterior of the project? Q Yes ^f No
6 Does this revision add ANY new floor area(s)? Q Yes ^ No
T Does this revision affect any fire related issues? Q Yes 0" No
8 Is this a completeseLttiatxeplaces the ong>/ali5ermitted set? Q Yes J^ No
^Signature
1635 Faraday Carlsbad, CA 92008 Ph/ne 760-6^2-2717/2718/2719/ 2721 Fax 760-602-8558
City of Carlsbad 07-1875(PCR08-38)
0^4/11/2008
\ EsGil Corporation
\_ In Partners Kip witfi. government for (Buifding Safety
DATE O4/ 11/2008 qjNPPI [CANT
JURISDICTION City of Carlsbad "D-Pt«rTT?EVIEWER
Q FILE
PLAN CHECK NO 07-1875(PCR08-38) SET I
PROJECT ADDRESS 2808 Cacatua Street
PROJECT NAME Malloy addition (Revision 1)
The plans transmitted herewith have been corrected where necessary and substantially
comply with the jurisdiction's building codes
XI The plans transmitted herewith will substantially comply with the jurisdiction's building
codes when minor deficiencies identified below are resolved and checked by building
department staff
The plans transmitted herewith have significant deficiencies identified on the enclosed
check list and should be corrected and resubmitted for a complete recheck
The check list transmitted herewith is for your information The plans are being held at
Esgil Corporation until corrected plans are submitted for recheck
The applicant's copy of the check list is enclosed for the jurisdiction to forward to the
applicant contact person
The applicant's copy of the check list has been sent to
XI Esgil Corporation staff did not advise the applicant that the plan check has been
completed
Esgil Corporation staff did advise the applicant that the plan check has been completed
X] REMARKS Please transfer redlme on S-2 to City set
By Aaron Goodman Enclosures
Esgil Corporation
D GA D MB D EJ D PC 04/07/2008
Cfcy of Carlsbad 07-1875(PCR08-38)
04/11/2008
VALUATION AND PLAN CHECK FEE
JURISDICTION City of Carlsbad
38)
PREPARED BY Aaron Goodman
BUILDING ADDRESS 2808 Cacatua Street
PLAN CHECK NO 07-1875(PCR08-
DATE 04/11/2008
BUILDING OCCUPANCY R-3 TYPE OF CONSTRUCTION V-N
BUILDING
PORTION
Beam revision
Air Conditioning
Fire Sprinklers
TOTAL VALUE
Jurisdiction Code
AREA
( Sq Ft )
cb
Rldn Pprmit FPP h\/ Drrlmanro V
Valuation
Multiplier
By Ordinance
Reg
Mod
VALUE (S)
Plan Check Fee by Ordinance , ^1
Type of Review D Complete Review
Q Other
r—i Hourly
$12000
Structural Only
Fee
•vTi Repeats
* Based on hourly rate
Comments
1 Hour*
Esgil Plan Review Fee $9600
Sheet 1 of 1
macvalue doc
o H S ^°> o§F so> o oS m WmIs