Loading...
HomeMy WebLinkAbout2808 ROOSEVELT ST; ; CB901882; PermitBUILDING PERMIT Permit No: CB901882 01/03/91 11:12 Project No: A9002158 Page 1 of 1 Development-No: Job Address: 2808 ROOSEVELT ST Str: Fl: Ste: 01/03fl1 0001. 01 2 Permit Type: COMMERCIAL TENANT IMPROVEMENT c-MT 2258-00 '203-182-04-00 Parcel No: -. Valuation: 9,266 AQ Construction Type: VN . . - Occupancy Group: B2 Class Code: . Status: ISSUED Description: 4528F JAZZERCISE Applied: 12/03/90 ADD SHOWERS, LOCKER, TOILET ROOMS Apr/Issue: 01/03/91. . Validated By: CD Appl/Ownr : ROOSEVELT CENTER CARLSBAD 714 472-2495 23282 MILL CREEK ROAD #220 LAGUNA HILLS, CA 92653 CONTRACTOR : WHITE CONSTRUCTION2 (( /A\ 1-Lic.'SC 452513 619-753-9272 7220 EL CAMTNO,REAL2 CARLSBAD 6A 9Z'öô9\ *** Fees Required / Fes..Cá]J'ected & Credits / .\ \1 J \ Fees: 21, 340 o/ \ \ Adjustments: .' I • TotalCedi-t-s: \ .00 I ) '-•---_• ç-,) \ Total Fees: . I 2,334.00' ------Tota-lPaymentz: 76.00 I :-•----' I --r:2ica4ance Due.: \ 2,258.00 Fee description{ Ext fee Data Build ing Permit : 76.00 Plan Check 117.00 Strong Motion Fee \ f / / . 1.00 Enter. 'Y' to Auto a". Licénse1Tax > \,J / / 324.00 Y Enter Number of EDU's ' 1C>000O 110-100 / MFF .. •\ > 1713 /. -1713.OQ BUILDING'TOTAL .2231.,00 Enter •"Y" for Plumbing Issue Fee/ f i\ \V' / 7.50 Y Eac ) h Plumbing Fixture or Trap f 9.007 2.50 22.50 Each Building Sewer > 1..00 6.50 6.50 Each Water' Heater and/or Vent --------i.00 - 2.50 2.56 * PLUMBING TOTAL - . 39.00 Enter "Y' for Electric Issue Fee > 5.00 .Three Phase Per AMP > .- 60.00 .50 . - 30.00 * ELECTRICAL TOTAL ($10 Minimum) - • 35.00 Enter '1' for Mechanical Issue Fee> . • . 15.00 1 Each Instali/Reloc Appliance Vent > 3.00 4.50 13.50 * MECHANICAL TOTAL '. - . •, . 29.00 PROVAL DATE-2~IJ • , .AJ'ftt 1NS I -. . • * CLEARANCE - . CITY OF CARLSBAD 2075 Las Palmas Dr., Carlsbad CA 92009 (619) 438-1161 11 PERMIT APPLICATION City of Carlsbad Building Department 2075 Las Palmas Dr., Carlsbad, CA 92009 (619) 438-1161 1. PERMIT TYPE I A - [-]COMMERCIAL UNEW $TENANT IMPROVEMENT B []INDUSTRIAL DNEW DTENANT IMPROVEMENT C - DRESIDENTIAL DAPARTMENT OCONDO [-]SINGLE FAMILY DWELLING DADDITION/ALTERATION DDUPLEX DDEMOLITION DRELOCATION DMOOILE HOME DELECTRICAL D PLUMB ING DMECHANICAL DPoOL DSPA DRETAINING WALL DSOLAR DOTHER_______________ EST. VAL PLAN CX DEPOSIT 7 Al VALID. BY DATE ng or Nearest Cross Streets 2 Energy Calcs 112 Structural Calcs 112 Soils Report []1 Addressed Envelope ASSESSOR'S PARCEL 94 EXISTING USE PROPOSED USE BLDG. SO. FTC. # OF STORIES 3. CONTACT PERSON NAME ADDRESS CITY - STATE 4A. ZIP CODE f7e&'Z;~DAY TELEPHONE SIGNATURE APPLICANT 0 CONTRACTOR OYAGiNT FOR CONTRACTOR DOWNER GENT FOR OWNER NAME' Jjj,j/ ADDRESS 4JCl CITY STATE ZIP CODE T€22E7 DAY TELEPHONE PROPERTY OWNER NAME "sJNER DLESSEE DTENANT L—TPI e'c in) CITY STATEC ZIP CODE ThL-L---,77 DAY TELEPHONE CONTRACTOR NAMEfl J7J ADDRESS CITY STATEc ,. ZIP CODE DAY TELEPHONE 1 -7, STATE LIC. LICENSE CLASS CITY BUSINESS LIC. N SIGNATURE TITLE - DATE U'UNeI'Rmc RUUNt5 gç CITY C 6 pL._?22/'7 STATE ZIP CODE DAY TELEPHONE c.'ft i C. WORKERS' COMPENSATION Workers' Compensation Declaration: I hereby affirm that I have a certificate of consent to self-insure issued by the Director of Industrial Relations, or a certificate of Workers' Compensation Insurance by an admitted insurer, or an exact copy or duplicate thereof certified by the Director of the insurer thereof filed with the Building Inspection Department (Section 3800, Lab. Q. INSURANCE COMPANY POLICY NO. EXPIRATION DATE Certificate of Exception: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. SIGNATURE DATE OWNER-BUILDER DECLARATION Owner-Builder Declaration: I hereby affirm that I am exempt from the Contractor's License Law for the following reason: I as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon,, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale.). I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Cede: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) Licensed pursuant to the Contractor's License Law). 0 I am exempt under Section Business and Professions Code for this reason: CSec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law (Chapter 9, commencing with Section 7000 of Division 3 of the Business and Professions Code) or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($5001). SIGNATURE DATE COMPLETE THIS SECTION FOR NON-RESIDENTIAL BUILDING PERMITS ONLY: Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under. Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? DYES ONO Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? DYES ONO Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? DYES DRo IF AllY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED AFTER JULY 1, 1989 UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POtLUTION CONTROL DISTRICT. CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec 3097(i) Civil Code). LENDERS NAME LENDER'S ADDRESS APPLICANT'S SIGNATURE I certify that I have read the application and state that the above information is correct. I agree to comply with all City ordinances and State laws relating to building construction. I hereby authorize representatives of the City of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS. COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. Expiration. Every permit issued by the Building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days (Section 303(d) Uniform Building Code). ICANTS SIGNATURE OWNER []CONTRACTOR []BY PHONE APPROVED BY: DATE: WHITE: File YELLOW: Applicant PINK: Finance SE.WER PERMIT 01/03/91 11:20 Permit No: 5E900163 Page lof I Job Address: 2808 ROOSEVELT ST Permit Type: SEWER - COMMERICAL/INDUSTRIAL 0145 01/03/91 0001 01. 02 Parcel No: 203-182-04-00 c-PRMT 1250.00 Description: JAZZERCISE INC. Status: ISSUED : OFFICE TO SHOWER CONVERSION Applied: 12/06/90 Apr/Issue: 01/03/91 Permitee: ROOSEVELT CENTER CARLS&AD 714 472-2495 Expired: 23282 MILL CREEK ROAD. #220 Prepared By: S.S. LACUNA HILLS, CA 92653 *** Fees Required Fees Collected & Credits Fees: 1,250.0 ' /\ Adjustments: fo9.\\ j.,5redits: .00 Total Fees: .1,250.00' \. Total Payments: 1,250.00 / .Banc'eDu• . .00 Fee description / .S\ - .JJnitsJFee/Unit Ext fee Data ____J---- ------ ------------- Enter Square Footae/L / 800.00\_-l.0. 1.00 Sewer Fee 2 1250.00 SEWER TOTAL ( 1250.00 CITY OF CARLSBAD 2075 Las Palmas Dr., Carlsbad CA 92009 (619) 438-1161 CITY OF CARLSBAD INSPECTION REQUEST _4C PERMIT# CB901882 FOR 02/05/91 INSPECTOR AREA PD DESCRIPTION: 452SF JAZZERCISE PLANCK# CB901882 ADD SHOWERS, LOCKER, TOILET ROOMS 0CC GRP CONSTR. TYPE VN STR: FL: STE: PHONE: 714 472-2495 PHONE: 619-753-9272 PHONE: INSPECTOR TYPE: CTI JOB ADDRESS: 2808 ROOSEVELT ST APPLICANT: ROOSEVELT CENTER CARLSBAD CONTRACTOR: WHITE CONSTRUCTION OWNER: REMARKS: NH/TRAVIS/953-9272 SPECIAL INSTRUCT: TOTAL TIME: --RELATED PERNITS-- PERNIT# TYPE STATUS SE900163 SWCI ISSUED CD LVL DESCRIPTION ACT COMMENTS 19 ST Final Structural 29 PL Final Plumbing 39 EL Final Electrical 49 ME Final Mechanical INSPECTION HISTORY ***** ***** DATE DESCRIPTION ACT INSP COMMENTS 011491 Interior Lath/Drywall AP PD 011191 Interior Lath/Drywall AP PD 010491 Underground/Under Floor PA PD VERIFY 4" 13 PLANNING, ENGINEERING FINAL INSPECTION Date________ Address _ °'" Plan #___________ Type of Construction________________________________________ Person to Contact Ph. No. 2/0/ Remarks: Date _____ Approval - I N S P E C I 0 N R E 0 U E T ESGIL CORPORATION 9320 CHESAPEAKE DR., SUITE 208 SAN DIEGO, CA 92123 (619) 560-1468 O APPLICANT JURISDICTION [j-PLAN CHECKER OFILE COPY []UPS !DESIGNER DATE: JURISDICTION: CIbe PLAN CHECK NO: go- SET: IS PROJECT ADDRESS: 06 ()1; Qe,361SCUIXAL~~rew_ PROJECT NAME: V1 L405;2) tTotLEc \c.. LT The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will si\bstantially comply with the jurisdiction's building codes i when minor deficien- cies identified are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. L...J The plans are being held at Esgil Corp. until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to return to the applicant contact person. EJ The applicant's copy of the check list has-been sent to: Esgil staff did not advise the applicant contact person that plan check has been completed. [J Esgil staff did advise applicant that the plan check has been completed. Person contacted:________________________ Telephone #________________ REMARKS: E- 0 1 A tn-e_ . a-cz 4ke 0 0 rOr. pr- t2#'Or? O- rzs By: Enclosures:____________________ fO ESGIIORPORATION EGA DAA ORN 0DM Date contacted: ESGIL CORPORATION 9320 CHESAPEAKE DR., SUITE 208 SAN DIEGO, CA 92123 (619)560.1468 DATE: JURISDICTION: CARLSBAD PLAN CHECK NO: C70I86 SET: I PROJECT ADDRESS: 209 ooe.,cM- 4r4 9 APPLICANT 4JUR1SD1CT10N 9 PLAN CHECKER 9FILE COPY. []UPS ODESIGNER PROJECT NAME: •11? inc. 1'oe 14 (!.grl±- LcrIbad LTD E] The plans transmitted herewith have been corrected where necessary and substantially, comply with the jurisdiction's building codes. fl The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficien- cies identified are resolved and checked by building department staff. o The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corp. until corrected plans are submitted for recheck. j Theapplicant's copy of the check list is enclosed for the jurisdiction to return to the applicantcontact person. The applicant's copy-of the check list has been 'sent to: 0%4,• CJa5bacA) (k ) oos Esgil staff did not advise the applicant contact person that plan check has been completed. J Esgil staff did advise applicant that the plan check has been completed. Person contacted:________________________ Date contacted: Telephone # 0 REMARKS: JJ B y:kFier £z.pL Enclosures:___________________ ESGIrCc$RPORATION 9 GA 0 AA El RN 0DM 5'R IVRII-71 WOOZINW. W0 imi - ~ Date initial plan check completed: L/i 2/qp By: J PLAN CORRECTION SHM PLAN (K NO.: O- iSeL Date plans received by jurisdiction: JURISDICTION:CARLSBAD Date plans received by Esgil Corporation: Applicant contact person: Tel. -.---- BUILDING USE: __fl# a _pc\4r . _Ov!Xjs oy s64c e CMFZ0REWRD:PLEASEREAD TYPE OF (X)NSTRUCTION: V I.. — Plan check is limited to technical requirements ACTUAL AREA:-45 spr (TI \) contained in the Uniform Building Code, Uniform STORI: Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise plan check is based oil regulations enforced by the Building Inspection Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department, Fire Department or other departments. Code sections cited are based on the 1988 UBC.a -- The circled items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 303(c), 1988 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. addressed, i.e., plan sheet, specification. etc. submit the revised plans. NOTE: PAGE NUMBERS ARE Nor IN SJERCE AS PMSB HAVING NO 1tS NThG (XRRTIONS WERE LIST NO. 56 CARLSBAD TENANT IMPROVEMENT WITHOUT SPECIFIC ENERGY ZONE DATA OR POLICY SUPPLEMENTS, 1988 UBC Please make all corrections on the original tracings and submit two new sets of prints, and any original plan sets that may have been returned to you by the jurisdiction, to: or Esgil Corporation, 9320 Chesapeake Drive, Suite #208, San Diego, CA 92123, (619) 560-1468. Please make all corrections on the original tracings and submit two new sets of prints, and any original plan sets that may have been returned to you by the jurisdiction, to: The jurisdiction's building department. / Indicate on the Title Sheet of the plans, the I name of the legil owner and name of person responsible for the preparation of the plans. Section 302(d). 4. Each sheet of the plans must be signed by the person responsible for their preparation, even though there are no structural changes. Business and Professions Code. Plans and calculations shall be signed by the F California state licensed engineer or architect where there are structural changes to existing buildings or structural additions. Please include the California license number, seal, date of license expiration and date plans are signed. Business and Professions Code. / Provide the correct address and suite number of tenant space on the plans. Section 302(d). Provide a note on the site plan indicating the s' previous use of the tenant space or building being remodeled. Section 302. / When the character of the occupancy or use f changes within a building, the building must be made to comply with current Building Code requirements for the new occupancy. Please provide complete details to show the building with comply. Section 502. / UBC Section 304 requires the Building Official f to determine -. the total value of all construction work proposed undr this permit. On the first sheet of the plans indicate: f Type of construction of the existing building, present and proposed occupancy classifications of the remodel area and the occupant load of the remodel areas and the floor where the tenant improvement is located. Provide a note on the plans indicating if any f hazardous materials will be stored and/or used within the building which exceed the quantities listed in UBC Tables 9-A and 9-B. A complete description of the activities and ( processes that will occur in this tenant space should be provided. A listing of all hazardous materials should be included. The materials listing should be stated in a form that would make classification in Tables 9-A and 9-B possible. The building official may require a technical report to identify and develop methods of protection from hazardous materials. Section 901(f). If control areas are used for exceeding the exempt amounts of hazardous materials from Tables 9-A and 9-B, they shall be constructed of not less that required for a one-hour occupancy separation. Section 404. The number of control areas within a building used for retail/wholesale stores shall not exceed two; the number of control areas in buildings with other uses shall not exceed four. Footnote 1, Tables 9-A and 9-B. The aggregate quantity of any hazardous f materials "in use" and "in storage" shall not exceed the quantity listed in Tables 9-A and 9-B for "storage". Footnotes 2 and 3, Tables 9-A and 9-B. 17. Provide a statement on the Title Sheet of the plans that this project shall comply with Title 24 and 1988 UBC, UMC and UPC and 1987 NEC. Provide a fully dimensioned floor plan showing f the size and use of all rooms or areas within the space being improved or altered. Draw the plans to scale and indicate the scale on the plan. Section 302(d). a value skoll inciuqe all iinisn WOrK, painting, roofing, electrical, plumbing, (19.) heating, air conditioning, elevator, fire extinguishing systems and any other permanent'( equipment. Please provide a signed copy of the designer's or contractor's construction cost estimate of all work proposed. I Provide a plot plan showing the distance from J f the building to the property lines and the J location of tenant space (or remodel) within the building. Vk.ose c\cn?'q ortz,\o, i -\-u 2 0 M Qc Indicate the use of all spaces adjacent to the area being remodeled or improved. Show any existing fire rated area separation walls, occupancy separation walls, demising walls, shafts or rated corridors. Identify and provide construction details for proposed new fire rated walls. Specify on the plans the fire ratings of assemblies to protect proposed openings in existing or new fire walls. 12/29/89 2 71 / Identify existing walls to be removed, existing walls to remain and new walls. proposed j4'. I In buildings having floors and roofs of wood frame construction, other than dwelling or Identify bearing walls, non-bearing walls, and hotel occupancies, draft stop the area between shear walls. the ceiling and floor above so that no concealed space exceeds 1,000 s.f. and no 23. Provide a section view of all new interior horizontal dimension exceeds 60 L.F. (if space epartitions. Show: has sprinklers, then 3,000 s.f. and 100 L.F.). Section 2516(f). Type, size and spacing of studs. Indicate gauge for metal studs. Specify 2/. In buildings having floors and roofs of wood manufacturer and approval number or / frame construction, other than dwelling or indicate "to be ICBO approved", hotel occupancies, draft stop the area between Method of attaching top and bottom plates the ceiling and roof above so that no to structure. (NOTE: Top of partition concealed space exceeds 3,000 s.f. and no must be secured to roof or floor framing, horizontal dimension exceeds 60 L.F. (if space unless suspended ceiling has been designed has sprinklers then 9,000 s.f. and 100 L.F.). for partition lateral load). Section 2516(f 5. Wall sheathing material and details of j attachment (size and spacing of 2. Storage areas exceeding 1000 sq. ft. in fasteners). / connection with wholesale or retail sales Show height of partition and suspended shall be separated from the public area by a ceiling, and height from floor to roof one-hour occupancy separation. If the entire framing or floor framing. building has an automatic sprinkler system, then the occupancy separation need not be 74. Provide notes and/or details to show that the provided. f floor and wall finish in toilet -rooms are surfaced with a smooth hard non-absorbent . An automatic sprinkler system shall be material extending five inches up the wall. I installed in rooms used by the occupants for Similar surfacing shall be provided on the the consumption of alcohol and in accessory walls from the floor to a height of 4 feet uses where the total area of such unseparated around urinals and within water closet rooms and assembly uses exceeds 5000 square compartments. Section 510(b). feet. Section 3802(c). Note on the plans: "All interior finishes must /. The tenant space and new and/or existing comply with Chapter 42 of the UBC". Specify f facilities serving the remodeled area must be "Class flame spread rating (minimum) accessible to and functional for the for - .01 physically disabled. See the attached correction sheet. Title 24, Part 2. 26. / Lateral bracing for suspended ceiling must be provided. (UBC Table 23-P) Where ceiling is 3J. The width of the required level area on the not supporting interior partitions, ceiling I side into which doors swing shall extend 24 bracing shall be provided by four No. 12 gauge inches past the strike edge for exterior doors wires secured to the main runner within 2 and 18 inches past the strike edge for inches of the cross runner intersection and interior doors. Section 2-3304, Title 24. splayed 90 degrees from each other at an angle I not exceeding 45 degrees from the plane of the ). Specify lever-type hardware for passage doors ceiling. A Strut (adequate to resist the on floors accessible to the disabled. Section vertical component from lateral loads) fastened 2-3304, Title 24. to the main runner shall be extended to and fastened to the structural members of the roof j. If both sexes will be employed and the number or floor above. These horizontal restraint f of employees exceeds four, provide separate points shall be placed 12 feet o.c. in both toilet facilities for men and women. If "both directions with the first point within 6 feet sexes will be employed and the total number of of each wall. Attachment of restraint wires to employees will not exceed four", and only one the structure above shall be adequate for the restroom is provided, note the words in load imposed. UBC Standard 47-18. . quotation above on the floor plan. Section 705. In areas where the occupant load exceeds , I two exits are required. See________________ Table 33-A. 2/15/90 3 . Provide an exit analysis plan (may be 8 1/2" x I 11" or any convenient size). J• Exits should have a minimum separation of one-/ half the maximum overall diagonal dimension of the building or area served. Section 3303(c). A. The maximum number of required exits and their f required separation must be maintained until egress is provided from the structure. Section 3303(a). Rooms with more than 10 occupants may have one / exit through one adjoining room. Revise exits to comply. Section 3303(e). 9€. Exit signs are required for exits serving an I occupant load exceeding 49. Show all required exit sign locations. Section 3314(a). 4j. Show that exits are lighted with at least one I foot candle at floor level. Section 3313(a). 46. Show the locations of existing exits from the f building and show the path of travel from the remodel area to the existing exits. 43. Note on the plans: "All exits are to be openable from inside without the use of a key or special knowledge". In lieu of the above, in a Group B occupancy, you may note "Provide a sign on or near the exit doors reading THIS DOOR TO REMAIN UNLOCKED DURING BUSINESS HOURS". This signage is only allowed at the main exit. Section 3304(c). Exit doors should be a minimum size of 3 feet / by 6 feet 8 inches with a minimum door swing of 90 degrees. Maximum leaf width is 4 feet. Section 3304(f). If. Exit doors should swing in the direction of / egress when serving an occupant load of 50 or more or when serving any hazardous area. Section 3303(b). Applies to door(s)_________ 9€. Regardless of occupant load, a floor or landing I not more than 1/2 inch below the threshold is required on each sidà of an exit door used for disabled access (may be 1" maximum where not used for disabled access). Section 3304(i). if. Doors should not project more than 7 inches f into the required corridor width when fully opened, nor more than one-half of the required corridor width when in any position. Section 3305(d). 9€. Revolving, sliding and overhead doors are not / permitted as exit doors if the occupant load exceeds 9 or the exit door serves a hazardous area. Section 3304(h). 41. Exit doors from assembly rooms with 50 or more I occupants shall not be provided with a latch or lock unless it is panic hardware. Section 3318. 5/. Double acting doors are not allowed when / serving a tributary occupant load of more than 100, or when part of a fire assembly, or part of smoke and draft control assemblies or when equipped with panic hardware. Section 3304(b). Corridors must provide continuous protection f to the exterior of the building. Interruptions by an intervening room is not permitted; Foyers, lobbies or reception rooms constructed as required for corridors are not considered intervening rooms. Section 3305. Corridors and exterior exit balconies serving / 10 or more occupants must be a minimum 44 inches wide and 7 feet high to the lowest projection. Corridors serving less than 10 occupants must be a minimum of 36 inches in width. Section 3305(b). When two exits are required, dead end / corridors and exit balconies are limited to 20 feet. Section 3305(e). Corridors serving 30 or more occupants shall I have walls and ceilings of one-hour construction except: Corridors greater than 30 feet wide when the occupants have an exit independent from the corridor. 1. Exterior sides of exterior exit I balconies. Corridor walls and ceilings need not be ( of fire-resistive construction within office spaces having an occupant load of 100 or less when the entire story in which the space is located is equipped with an automatic sprinkler system throughout and smoke detectors are installed within the corridor in accordance with their listing. Section 3305 (g). 1. Section 3305(g), Exception 5, cannot be used I for non-rated corridors in a fully sprinklered office space if the occupant load in the space exceeds 100. Section 3365(g), Exception 5 does not apply to f common corridors where the corridor serves as an exit for non-office areas (manufacturing, warehouse, etc.). 2 /14/90 4 Section 3305(g), Exception 5 is applicable only f . for corridors on one floor.; the corridors on the lower level(s) must be rated if these lower corridors have openings into them from other levels. If non-rated corridors are used per Section f 3305(g), Exc. 5, provide a reference to the corridors on the floor plan, noting: Corridors are non-rated per Section 3305(g), Exception 5. Smoke detection system must be listed by the State Fire Marshall.. and be a supervised low voltage system. Smoke detectors shall be maximum 30' on center. Power supply shall be dedicated branch circuit. Circuit disconnecting means shall be. accessible only to authorized personnel and shall be clearly marked FIRE ALARM CIRCUIT CONTROL, with a lock-on device. If a tenant space utilizes Section 3305(g), f Exception 5, then that tenant space shall be separated from adjacent spaces by a demising wall constructed as for a one-hour corridor wall. Clearly show where the non-rated corridor ( system terminates and a rated corridor system commences. 4/. One-hour fire-rated corridors shall have door openings protected by tight-fitting smoke and draft control assemblies rated 20 minutes, except openings in interior walls of exterior exit balconies. Doors shall be maintained self-closing or be automatic-closing by action of a smoke detector per Section 4306(b). Doors shall be gasketed to provide a smoke and draft seal where the .door meets the stop on sides and top. Section 3305(h). 4/. Show rated corridors, lobbies, reception or foyers cross-hatched on the floor plans. 41. Total area of all openings, except doors, in f any portion of an interior corridor, shall not exceed 25 percent of the area of the corridor wall of the room which it is separating from the corridor. Such openings shall be protected by fixed, approved 1/4 inch thick wired glass installed in steel frames. Section 3305(h). ci. Provide a complete architectural section of f the corridor, or exterior exit balcony, showing all fire-resistive materials and details of construction for all floors, walls, ceiling and all penetrations. Section 3305(g). Show the location of fire dampers. Provide fire dampers at duct penetrations of fire- rated occupancy and area separations, shafts and corridor walls and ceilings. Section 4306(j). (. If a room with an exhaust fan has a door f opening into a rated corridor, show how make- up air will be provided to the room. The door cannot be undercut, nor can a louver in the door be provided. Section 3305(h)1. If building exceeds two stories and has an f elevator opening into a rated corridor, show how the smoke and draft control provision of Section 3305(h) will be met. Either provide a separated elevator lobby or a second door at the elevator entry meeting the provision. 6j. If a second door is provided at the elevator / entry, note that it will be readily openable from the car side without a key, tool or special knowledge or effort. Section 5106. 4/. Provide evidence of Health Department approval / . (for restaurants or for tenants using X-ray ' equipment). i4. When nonflammable supply cylinders for medical gas systems are located inside buildings, they shall be in a separate room or enclosure separated from the rest of the building by not less than one-hour fire-resistive construction. Doors to the room or enclosure shall be self-closing smoke- and draft-control assemblies having a fire-protection rating of not less than one hour. Rooms shall have at least one exterior wall in which there are not less than two vents of not less than 36 square inches in area. One vent shall be within 6 inches of the floor and one shall be within 6 inches of the ceiling. When an exterior wall cannot be provided for the room, automatic sprinklers shall be installed within the room and the room shall be vented to the exterior through ducting contained within a one-hour- rated shaft enclosure. Approved mechanical ventilation shall provide six air changes per hour for the room. Section 702(b)4. 6/13/90 5 ELECTRICAL kceS Submit plan showing location of all panels. Submit panels schedules. Submit electrical load calculations Indicate existing main service size. Indicate existing total main service load. Indicate new additional loads. Indicate wiring method, i.e. EMT, metal flex. Show exit signs on the electrical lighting plan(s). As per Section 3313 and 3314 of the 1988 UBC, provide twósources of power to exit signs and exit illumination. Provide receptacle(s) within 25' of the roof mounted A/C units. UMC Section 509. Provide multiple switch lighting controls per Title 24, 2-5319. Provide an electrical plan for the alarm system showing compliance with criteria described under earlier correction number 54. Provide mechanical ventilation in all rooms capable of supplying a minimum of 5 cubic feet per minute of outside air with a total circulation of not less than 15 cubic feet per minute per occupant. Section 605 and 105,: UBC. Provide mechanical plans showing existing and proposed HVAC equipment, ducts and access to equipment. Detail access and working clearances to HYAC equipment. Cooling coils or cooling units located in attic or furred space, where damage may result from condensate overflow, shall be provided with an additional water tight pan of corrosion resistant material to catch overflow if primary condensate drain becomes clogged. Section 1205, UMC. One-hour corridors shall not be used as an integral part of a duct system. This includes the space above a dropped ceiling within the one-hour corridor. UMC Section 706(b). PUBBThG Provide gas line plans and calculations, showing pipe lengths and gas demands. UPC Section 1219. Provide drain, waste and vent plans. Provide water line sizing calculations. UPC Section 1009. Detail how floor drain trap seal is to be maintained. UPC Section 707 (floor drain trap priming). Show P & T valve on water heater and detail drain line route from P & T valve to the exterior. UPC Section 1007(e). Show 1/4" per 12" slope on drain and waste lines. UPC Section 407. Provide a drinking fountain at each floor level in assembly occupancies (except drinking and dining establishments). UBC Section 605. GY Provide complete energy design calculations, including all existing design and new energy design for this building. See attached non- residential energy design checklist. For remodels in an existing conditioned space, show that the remodeled space will not use more energy than the existing space or show the remodeled space will conform to latest energy design standards. CITY OF CARLSBAD SUPPLEMENT Floor drains must have auto-prime (City Policy). A grease interceptor is required. Show details complying with City Policy 83-34. Roof mounted equipment must be screened and roof penetrations should be minimized (City Policy 80-6). Condensate drains must connect to a wet trap (dry traps are not permitted). (Memo 1/14/83). Show fans are duct type; City Policy does not permit ductless fans. Romex is not permitted in industrial or commercial buildings. (City Policy) No wiring is permitted on the roof of a - building and wiring on the exterior of a building requires approval by the Building Official. (City Policy) All panel boards shall have a minimum 100 amp rating or approved by the Building Official. 4/6/90 6 The minimum rating of a service disconnect is 100 amperes. The minimum size conductor to receptacles and lighting fixtures in commercial and industrial buildings shall be #12 Cu. AC(BX) cable is not allowed in group A, B, E, H and I occupancies. (see Ord. for exception) PascELLANkx)us 07 Please see additional corrections or remarks that follow. 108 To speed up the recheck process, note on this list (or a copy) where each correction item has been addressed, i.e., ..plan sheet, note or detail number, calculation page, etc. 109. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please check. Yes No The following provisions are contained in Title 24, Part 2, California Building Code, as adopted and enforced by the State Fire Marshall. They are provided here as a courtesy to assist designers in developing the project documents. All applicable provisions may not necessarily be included. Please direct any questions regarding interpretations of these provisions to the local Fire Department. Walls of corridors and exterior exit balconies f in Groups A,E,I,R-1 and C Occupancies having an occupant load of more than six persons and in all other occupancies having an occupant load of 30 or more shall be not less than one-hour fire-resistive construction. Section-3305(g)l. Sf4. Where exit signs. are. required by Section / 3314(a), approved and 'listed internally, externally or self-illuminated-low-level exit signs complying with Section 3314 shall be required. The bottom of the sign shall be not less than 6 inches nor more than 8 inches above the floor level. For exit way doors, the sign shall be on the door with the closest edge of the sign with 4 inches of the door frame or adjacent to the door. Such signs shall be of a type which is perceptible to the sense of touch. Section 3314(e). sl. Where exit signs are required by Section f 3314(a), all exit corridors shall be provided with continuous low-level exit path marking. Approved and listed internally or self- illuminated marking shall be installed at floor level or no higher than 8 inches above the floor level. Such marking shall be of a type which is perceptible to the sense of touch. Section 3314(f). Area separation walls shall not be considered f to create separate buildings for the purpose of automatic fire-sprinkler system requirements as set forth in Chapter 38. Section 505(e)6. EXCEPTION: Buildings separated by continuous area separation walls of four-hour fire- resistive construction without openings. Buildings required to have automatic fire- sprinkler protection as set forth in Section 13113 of the Health and Safety Code (homes for children or the aged) are prohibited from using area separation walls in lieu of automatic fire-sprinkler protection. S. In educational occupancies, storage and f janitor closets shall be of one-hour fire- resistive construction with openings protected by assemblies having at least a three-fourths- hour fire-resistive rating. Section 802(c). S/6. Section 1807 should be reviewed for all high- rise buildings. The exception in Section 3318 of the UBC has / been revised so as to allow the omission of panic hardware at the main exit in churches (by using signage), only when the occupant load of the church is less than 300. /8. If emergency warning systems are required, they shall activate a means of warning the hearing impaired. Flashing visual warnings shall have a frequency of not more than 60 flashes per minute. The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 619/560-1468, to perform the plan check for your project. If you have any questions regarding these plan check items, please contact_________________ 5o -Lt,eIa at Esgil Cen Vration Thank you. Enclosures: 2/28/90 7 IGZMTCAL PLAN COMMMON SHEM 3URISDIC'ZIOi: DAlE: '• - F O VOUJZ WA PLAN QmXZ NIPB: C6- fo - PLAN RA! MEAL C] DARRU1 MDRRISON To speed up the recheck process,ñote on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, specification, etc. Be sure to enclose the marked up list when you submit the revised plans. Submit complete electrical plans and specifications. Submit plan showing location of all services. / Submit complete one-line diagram of service and feeders. )i. Indicate the grounding system to be installed for building service. IX Indicate ampere interrupting capacities (AIC) of service and subservice equipment. NEC 230-65/110-9. Indicate sizes of fuses and/or circuit breakers. ,X Indicate fuse symbols to show fault currents are limited to 10,000 amps on branch circuits, i.e. .TJN, LCL. ,8 If fuses are not used to limit fault currents on branch circuits to 10,000 amps, specify method to be used. Submit plan showing location of all switchboards. -. Indicate dimension of switchboards and control panels rated 1200 amperes or more. NEC 110-16(c). Submit plan showing location of all transformers. LZ Indicate the grounding system to be installed for transformers. NC 250- Provide overcurrent protection on the secondaryside of transformers. NEC 240- 21/384-16(d). Submit plan showing location of all panels. Submit panel schedules. )6'Specify conduit and wire sizes. ) Specify aluminum or copper conductors and type of insulation. Show approximate length of feeders. Specify electrode conductor site and type wire. (aluminum or copper) Submit electrical load calculations. )l. Indicate existing main service size. Indicate existing main service load. Indicate new additional loads. .M.".'Indicate wiring method, i.e. EMT, metal flex. Show exit signs on the electrical lighting plan(s). As per Sec. 3313 and 3314 of the 1988 UBC, provide two sources of power to exit signs and exit illumination. ).V. Provide receptacle(s) within 25' of the HVAC A/C units. UMC Section 509. 26(c). 82i. Provide multiple switch lighting controls per CAC, Title 24, 2-5319. c.'Qe. •ZA?1p? -. f - Any questions on electrical please contact the plan checker shown above, at Esgil Corporation at (619)4 /Z 560-1468. Thank you. ELECTRICAL CORRECTIONS ' C.u4T 6.f..5. DAlE D&M I( 7,11119c C.uQc.uEo rrTV ?t..A,i CHL.L* 2"tO-tQS2 AA 0 6 A,O oJO1 1jt'i PLET t TFnC AAS A & t I& (A LLU LAT bf'J . IED Th BAC VIENTEDICbOL ?Rp/IOc. P £-A"Th S4ø,J U,.SiflflcnJEo itR AtA. LOInPL -r LIK t—t, o- I AuO -i-i1r - nPui fLACJ'J AND u ¶A1io frv%D A-r iJAr)-r mrRo/e.- o3 o,ürriôt ot AiA Per LE to ?Aa F Cs-IA OF- C-l3 44r,J Aid, ifi'iOAii J2I c'Jo-r MA 91Af. is Oaiu1 c-% i (J-%A OZ. cc-i E - --GlftodIOE. 1tOr'J if'JC. FrC ICPPU1J13L. LUPPJCIIJ. IF dttDItJ(, Stirs ',pJr\ - £JPLV trflf eci RwAc AfPRtDA £.(4J fl-F -TetJAt3l- %mPD t3T AUL, LDrn&'-i !IJV1I+ -NA-r AfRoAc. _Q eem 1-7 -- AfofUCA'r%o0 AHoJ tomeLIr1T, crn AND CA T%o -ro Corn eL'S wrr41 T* - Mg!J )PA(JC1 Lf'e. CC3. SikW ALL Ji2LED iNJLAThfJ /Au), ArJO Aflot'i5 OfI RANS P6 PEP— CALLU LAMbAJ6 . WcwQ f'tt..S A,JD SIbAJ Te. Rw.iD lUL.ATh CeQ-n turrE o Lb n Pt..i A licE. fjQ.M SII,L Sie 6'sLorO 134 fltA&)c,- AQ PJCA PAL- 1E I(tJI At F 9Ar 2 Aim' 19KIt.oP; UihTirJ( AJO IAVAL MLJ'cf P (LETO APJD SU,rJtSO L. Lo5e ?Aer 3 r6e C. rn A L4 brM'L% A A) . v1 PAL- (N (2. cL /E.LDf. 1:?!9iL,r1R IS Aoh1gcr /ciUiL kEE). T*e Wy? &ILrIk L LA rAt_ ri1 e,16r3 k5 ftpikz4FL DEI1&)- 1DlZ JHU1 i: vrn,ibdt -r2J1rrLJAL t&k(. i s ?o'ostQ LEWfliJ AI 4'FT 'L A&o rnooi.a. t 1A.t, VJI,C... fW.Arr kr PRe1 '7_ Im9RtJ1 A (t-o L-A oQ. ON ?t.APJ,, t..cuJO (X-1X IF i'AQT G4% to t%j 'ACiL&& DJi £,J1AI1O,J L_4 p.hI.tnP JThtrflA1 44AD)l. Ira Jr N CALCJLATIOfJ& / - 1 6.JE.ML fv&c ELUcr uft- 56 C-.LtD ITn PLAO PArE. t.ste- 11 -110 c:Hcw. t') ID Iz- . AAM GAD . P&t. .AãS1. A eJO I ICA 'cbuJ /4' ?i FØT eF DE'A lra t.i,Jiac. soiLmirJ& DE?Ai)r3T APP(ZOVAL OF '/Bfc Fôr Stoft OF ).4' LJ1 A 407 A] Jsj15 Ar Ai..t- ISU(4,. /j ANs 1b HOv) cO -ILtiRL AEA OF /tJT' '5 &Jt To Ti-tRT OF 7. tJt, 1aZ R)i2D. -rci :n ttJD(ECT. v'/AT !LLJ PoUo \)L0 cn .cjc i'ri-i 4. 5cn03 tsOt StJU...O36 EAgThpJ1 DRAIrJA&e TA OA iiJ - s coeoc.. AiJO cJutiPQ..'i SwK,6 AP-g- PenWiggw io ujpicr - 5t( 5uu - buJ £Lf3( wiT1 Ji tjj'yt.3e, 3t tin2Aflot'i VJM-rE Ar,p 1EiuT TPcP6) hP'rzP Hzxti i4i 4.o.Z Pi&VJ oo ti\fl-4 12Af SEALS11) F.LS h144I1;m•t -SFi %4ôiJ .L iici , (-trAc TPP Q4E lifr,eC€i17(2. tT) 1) 4J pPkpT,& e& 1iAP1 D C'P1'&:tJr ii /MITht1 A eDAq jc.E dITI iflOrsi -7DzL6j 0I3C.. 1r1L1 PJI1-bI1J(I CEfl(J1 — IZ S4tu PoJT/ REP1 f& 1PrT i€ -r; P VALY9 - Re .SELT(cr w -i1- ou t. ror diO tc'T'O). I-cs Peadicl-S WccT.a UIJE 6lPJ& (LLt)I iwJ i3nIiiry f50121 MAXInlyrA — Pth.LoRO UrrH A,o nirflLvi fi TO 'M fl. PoJr IrJOtCATIA.)(- r.i m u rJ m f\ S FEE. / L4uJ ti-kS t1Ef tELTCt'l 1211. MoVive cPr' Lima AL(.4.(.Prflt&). i4 AuL. Lx)rLTtfl / ALL L4 41 k.JtD .1,1I4 D L4pJ16 flrEl. IC1 JT1J PlLmQ O t fiL uJrn4 Jfl i.rT '1 F. kAs ..S ELJi LE. / O PCViL VW< flDi(jyy o1e Sii2..tiic V2or1 - J,m-ri kriO 13L)ILDtPJCi. C%LsRt t w AEf -, A /5I9. c* CoABU1O Aie.. ?e. cno ro -L .Ji14 CrIrUJ r! SbL iJ JThR. I+tArR- WIU... TE ?QAaEn 1t E6'rr I6M% £. -Th thmft'1 WrrH JtAL- eflcJ '5o4CA) Ij Z-i (-./ fIgAntA w.) Awn tiTh?Q QfArgni e-4. 4ouJ6 5MAVL, - uA1-4 %Jc'Itht?UFrL- (oArrQ.oL, V n)(JN1 \/AW. -m LMLT I C-tZ.Rfl)fZ 1 ?t c-i-'ot °oci - 2 5IL) uJiTp APP ir t.. P2JO oJ.ueAMi LoeO €AkDbtJI'J OF -1--- kJO fl1t,JtrvJfl'% tJUm2..14 FPL%LI1 UI2O AND ____ ThLiJ AIA.. Ø%QL'O CA.EANDOT6. I Date K1/I2/f0 Jurisdiction CARLSBAD Prepared byt Bldg. Dept. VALUATION AND PLAN CHECK FEE • Esgi]. PLAN CHECK NO. TO 100 BUILDING ADDRESS _O9 o 'eIJ APPLICANT/CONTACT -I-. -'--- PHONE NO. - BUILDING OCCUPANCY ._B- DESIGNER PHONE_____________ TYPE OF CONSTRUCTION. V 4 CONTRACTOR PHONE___________ BUILDING PORTION BUILDING AREA VALUATION MULTIPLIER VALUE ' 4GZ I2O- 9 Air_Conditioninz Commercial .•. Residential Res. or Comm. Fire_Sorinklers Total Value Building Permit Fee S_ - Plan Check Fee S . $ O ' p - COMMENTS? . . SHEET I OF______ - . .. . . . I2IR7 [Z E:] F_~ 2. BUILDING PLANCHECK ENGINEERING CHECKLIST DATE: A NC qQ PLANCHECK NO.0 tRck7_. COMPLETE - 9. M ITEM INCOMPLETE EEDS YOUR ACTION 123 S R T D D C C C H H H E E E ~f 0H aô RF'FLT ar ITEM SELECTED AP''.1. 203—%82_-04 PROJECT ID:__________________________ LEGAL REQUIREMENTS Site Plan 1. Provide a fully dimensioned site plan drawn to scale. Show: north arrow, property lines, easements, existing and proposed structures, streets, existing street improvements, right-of-way width and dimension setbacks. Show on site plan: Finish floor elevations, pad elevations, elevations of finish grade adjacent to building, existing topographical lines, existing and proposed slopes, driveway with percent (%) grade and drainage patterns. Provide legal description and Assessors Parcel Number. Discretionary Approval Compliance EZO 0 4. No Discretionary approvals were required. EJ E 5. Project complies with all Engineering Conditions of Approval for Project No.________________ 6. Project does not comply with the following Engineering Conditions of Approval for Project No.___________________ Conditions complied with by: Date: Field Review NJL E E 7. Field review completed. No issues raised. 8. Field review completed. The following issues or discrepancies with the site plan were found: D El D A. Site lacks adequate public improvements El E B. Existing drainage improvements not shown or in conflict with site plan. El E E C. Site is served by overhead power lines. FRNOOlO.DH REV. 11/27/90 000 D. Grading is required to access site, create pad or provide for ultimate street improvement. E E E. Site access visibility problems exist. Provide onsite turnaround or engineered solution to problem. El E:1 El F. Other:___________________________________________ Dedication Requirements 9. No dedication required. E E 10. Dedication required. Please have a registered Civil Engineer or Land Surveyor prepare the appropriate legal description together with an 8½" x 11" plat map and submit with a title report and the required processing fee. All easement documents must be approved and signed by owner(s) prior to issuance of Building Permit. The description of the dedication is as follows:___________________________ Dedication completed, Date By: Impro~emenquirements E . p improvements required. SPECIAL NOTE: Damaged or defective improvements found adjacent to building site must be repaired to the satisfaction of the City inspector prior to occupancy. F-10012. Public improvements required. This project requires construction of public improvements pursuant to Section 18.40 of the City Code. Please have a registered Civil Engineer prepare appropriate improvement plans and submit for separate plancheck process through the Engineering Department. Improvement plans must be approved, appropriate securities posted and fees paid prior to issuance of permit. The required improvements are:______ Improvement plans signed, Date: by: FRN001O.DH REV. 11/27/90 13. Improvements are required. Construction of the public V improvements may be deferred in accordance with Section 18.40 of the City Code. Please submit a letter requesting deferral of the required improvements together with a recent title report on the property and the appropriate processing fee so we may prepare the necessary Future Improvement Agreement. The Future Improvement Agreement must be signed, notarized and approved by the City prior to issuance of a Building Permit. Future Improvement Agreement completed, Date:____________ By:_____________________ El El El 13a. Inadequate information available on site plan to make a determination on grading requirements. Please provide more detailed proposed and existing elevations and contours. Include accurate estimates of the grading quantities (cut, fill, import, export). El 14. No grading required as determined by the information provided on the site plan. El El El 15. Grading Permit required. A separate grading plan prepared by a registered Civil Engineer must be submitted for separate plan check and approval through the Engineering Department. NOTE: The Grading Permit must be issued and grading substantially complete and found acceptable to the City Inspector prior to issuance of Building Permits. Grading Inspector sign off. Date: by: Miscellaneous Permits El El 16. Right-of-Way Permit not required. El El El 17. Right-of-Way Permit required. A separate Right-of-Way Permit issued by the Engineering Department is required for the following: E El El 18. Sewer Permit is not required. 21 00 19. Sewer Permit is required. A sewer Permit is required concurrent with Building Permit issuance. The fee required is noted below in the fees section. El El 20. Industrial Waste Permit is not required. FRN0010.DH REV. 11/27/90 [I tJ/fl 23. [I tJ/,q 24. ON/A ON/A 0 N/A 28. Im 21. Industrial Waste Permit is required. Applicant must complete Industrial Waste Permit Application Form and submit for City approval prior to issuance of a Building Permits. Permits must be issued prior to occupancy. Industrial Waster Permit accepted - Date: By: Fees Reauired O t1/A 27. Park-in-Lieu Fee Quadrant: Fee per Unit:______________ Total Fees:- Traffic Impact Fee Fee Per Unit: Total Fee: Bridge and Thorough fare Fee Fee Per Unit: Total Fee: Public Facilities Fee required. Facilities Management Fee Zone: Fee: Sewer Fees Permit No.SEqOC'lo EDU's I Fee: 1250. ________________ Sewer Lateral Required: Fee:______________ 0 29. REMARKS:________________________________________ ENGINEERING AUTHORIZATION TO ISSUE PERMIT BY: s.cHErEw. DATE: Cr FC FRN001O.DH REV. 11/27/90 PLANNING CHECKLIST Plan Check No:fO- /Y9 7-Address 29'017 PpEI'J 53-. APN: 20 ?- /t"-o f Planner Phone 438-1161 (Name) Type of Project and Use Zone ____ Facilities Management Zone - - - (5 (5 (5 Legend >. >. >. 21' Item Complete Uuu u 4' 0 Item Incomplete - Needs your action C AP U C a. 1, 2, 3 Number in circle indicates plancheck number where deficiency w a s identified Qlblll Environmental Review Required: YES - NO 'TYPE rid DATE OF COMPLETION: Compliance with conditions of approval? If not, state conditions which require action. Conditions of Approval Discretionary Action Required: YES - NO TYPE APPROVAL/RESO. NO. DATE: PROJECT Nd. OTHER RELATED,CASES: • - •;,. Compliance with conditions of approval? If not, state conditions which require action. Conditions of Approval Coastal: YES - NO L DATE OF APPROVAL: Compliance with conditions of approval? If not, state conditions which 'require action. Conditions of Approval Landscape Plan Required: YES ___ NO / See attached submittal requirements for landscape plans Site Plan: Providea fully dimensioned site plan drawn to scale. Show: North arrow, property lines, easements, existing and proposed structures, streets, existing Street improvements, right-of-way width and dimensioned setbacks. /1 0' 0 Show on Site Plan: Finish floor elevations, elevations of finish grade adjacent to building, existing topographici lines, existing and proposed slopes and driveway. ZtIO Provide legal description of property. Provide assessor's parcel number. Zoning: 1iii 1. Setbacks: Front: Required Shown- Int. Side: Required Shown Street Side: Required Shown Rear: Required Shown C; KC,1 0 fr'4 2. Lot coverage: Required Shown FIWk 3. Height: Required Shown 0 0 /itfr 4. Parking: Spaces Required Shown Guest Spaces Required Shown C2'i'0"0 Additional Comments <b',' 191A ç ru4, 4J t'o A - 1f Li ,,Jc.,. OK TO ISSUE DATE ii 2.1-11 C: Data Enfry PLNCK.FRM 2560 ORION WAY Citp of ftar1bab CARLSBAD, CA 92008 TELEPHONE FIRE DEPARTMENT (619) 931-2121 PLAN CHECK REPORT PAGE 1 OF DISAPPROVED PLAN CHECK# PROJECT(JAZZe/eJ5F T&)c. ADDRESS lt,0 707 kaxIvEcr ARCHITECT OAh/L1 &iiJ/,A'O(n,P ADDRESS 'tiJ A i/b,4PHONE '/1JO3 OWNER ________________________ADDRESS—)-12,K2 AhUe r,4"S OCCUPANCY ____________ CONST. VA! TOTAL SQ. FT. STORIES SPRINKLERED 'TENANT IMP. APPROVAL OF PLANS IS PREDICATED ON CONFORMING TO THE FOLLOWING CONDITIONS AND/OR MAKING THE FOLLOWING CORRECTIONS: PLANS, SPECIFICATIONS, AND PERMITS Provide one copy of: floor plan(s); site plan; sheets Provide two site plans showing the location of all existing fire hydrants within 200 feet of the project. Provide specifications for the following: Permits are required for the installation of all fire protection systems (sprinklers, stand pipes, dry chemical, halon, COa, alarms, hydrants). Plan must be approved by the fire department prior to installation. The business owner shall complete a building information letter and return it to the fire department. FIRE PROTECTION SYSTEMS AND EQUIPMENT The following fire protection systems are required: O Automatic fire sprinklers (Design Criteria: Dry Chemical, Halon, CO2 (Location: O Stand Pipes (Type: 0 Fire Alarm (Type/Location: Fire Extinguisher Requirements: EIOne 2A rated ABC extinguisher for eachj22/ sq. ft. or portion thereof with a travel distance to the nearest extinguisher not to exceed 75 feet of travel. 0 An extinguisher w ith a minimum rating of ________ to be located: 0 Other: 8. Additional fire hydrant(s) shall be piovided -/ EXITS .A.... 9. Exit doors shall be openable from the inside without the use of a key or any special knowledge or effort. _10. A sign stating, "This door to remain unlocked during business hours" shall be placed above the main exit and doors EXIT signs (6" x 3/4" letters) shall be placed over all required exis and directional signs located as necessary to clearly indicate the location of exit doors. GENERAL Storage, dispensing or use of any flammable or combustible liquids, flammable liquids, flammable gases and hazardous chemicals shall comply with Uniform Fire Code. Building(s) not approved for high piled combustible stock. Storage in closely packed piles shall not exceed 15 feet in height, 12 feet on pallets or in racks and 6 feet for tires, plastics and some flammable liquids. If high stock pil- ing is to be done, comply with Uniform Fire Code, Article 81. _14. Additional Requirements. .S!51 Aij,rc cJS qcXDOc 15. Comply with regulations on attached sheet(s). Plan Examiner _c7'z4A(. I k Date Report mailed to architect ( J Met with Attach to Plans COMMERCIAL/INDUSTRIAL APPLICATION FORM FOR INDUSTRIAL WASTE DISCHARGE PERMIT - CITY OF CARLSBAD APPLICATION: NEW_____________ (CHECK ONE) REVISED K BY: Signature of City Representative BUILDING P.C. APPLICATION NO.: INDUSTRIAL CLASS: 3 i DATE: APPLICATION FOR FOR INDUSTRIAL WASTE DISCHARGE PERMIT GENERAL: SITE APPLICANT: JJZ'4' ILk2" ADDRESS:_____________________ TYPE OF BUSINESS:t-t"'p7 &-fI'vV'IP? T'U-'V f/A1_4T,e 7 APPLICANT'S ADDRESS: _22' P7a9 >/t,r ';1- WASTES AND PROCESSING: (Check where applicable) ;91 Domestic Waste Only f-f Industrial Waste fl Industrial Waste NOT Discharged to Sewer Discharged to Sewer GENERAL DESCRIPTION OF WASTE (Chemical and Physical Characteristics of proposed waste):______________________________________________________ M.1r97ncV 4 ta GENERAL DESCRIPTION OF PROCESS (If Applicable):_________________________ WASTES TO-BE DISCHARGED TO SEWER: WASTE: TREATED: QUANTITY: AVERAGE GPO (Check One) UNTREATED: - (Daily) MAXIMUM GPD (Gallons Per Day) APPLICANT OR REPRESENTATIVE OF FIRM: 2LflL1"( 'P1ikJ (Print) - TITLE: 1_ J49? £k11 14" SIGNATURE: fr_2SL1Ué3 /5r_O2ATE: 1/-