HomeMy WebLinkAbout2811 AVENIDA VALERA; ; CB920844; Permit08/25/32 10
Page 1 of Jog Address
Permit Type
BUILDING PERXIT
: 44
1
: 2811 AVENIDA VALERA Suite:
: SINGLE FAMILY DWLNG - DETACHED
Parcel No: 216-460-25-00 Lot#: 126
I Valuation: 158,770
Construction Type: VN
Occupancy Group: Rs'/Ml Reference#: 92-636
Description: 2006 SF.+ 406 SF GARAGE PLAN 1
: PHASE 1
Permit No:
Project Nct :
Development No:
9010 U8mm Oo010~
Status:
AppSTWT
Apr/Icc ,,ue :
Validated By:
Appl/Ownr : FIELDSTONE/LA COSTA ASSOC. 619 546-8226
5465 MOREHOUSE DRIVE #250
SAN DIEGO, CA 92121
k*x Fees Required *** *** Fees Collected & Credits
* PLUMBING TOTAL
Enter "Y" for Electric Issue Fee >
Single Phase Per AMP > * ELECTRICAL TOTAL
Enter 'Y' for Mechanical Issue Fee>
Install Furn/Ducts >
Each Install/Reloc Appliance Vent > Each Hood/Fireplace > * MECHANICAL TOTAL
0
0
0
0
1 9.00
4 4.50
1 6.50
0
125 .25
.oo
350.00
12,787.00
Ext fee ----______--
1035.00 673.00
21.00
2200.00
3871.00 Y
3573.00
362.00 Y
408.00
530.00 Y
12983.00
7.50 Y
40.00
6.50
2.53
2.50
5.00
64.00
10.00 Y
31.25
41.00
15.00 Y
9.00
18.00
6.50
49.00
310.00 06
--
t: a --
INSP.
CLEA
I
CITY OF CARLSBAD
2075 Las Palmas Dr., Carlsbad, CA 92009 (619) 438-1161
FINAL BUILDING INSPECTION
DEPT: BUILDING ENGINEERING FIRE PLANNING U/M WATER
PLAN CHECK#: CB920844 PERMIT#: CB920844 PROJECT NAME: 2006 SF + 406 SF GARAGE PLAN 1 PHASE 1
DATE : PERMIT 04/ 2 8/9 3 TYPE: SFD
ADDRESS: 2811 AVENIDA VALERA
CONTACT PERSON/PHONE#: ALLISON @ FIELDSTONE/438-0468 SEWER DIST: LC WATER DIST: CA
DATE
INSPECTED: 4@mm
INSPECTED DATE
BY : INSPECTED :
INSPECTED DATE
BY : INSPECTED :
APPROVED
APPROVED
APPROVED
DISAPPROVED
DISAPPROVED
DISAPPROVED
FINAL BUILDING INSPECTION
DEPT: BUILDING EPJGINEERING , FIRE PLANNING U/M
PLAN CHECK#: CB920844
PERMIT#: CB920844
PROJECT NAME: 2006 SF + 406 SF GARAGE PLAN 1
PHASE 1
WATER
DATE: 04/28/93
PERMIT TYPE: SFD
ADDRESS: 2811 AVENIDA VALERA
CONTACT PERSON/PHONE#: ALLISON @ FIELDSTONE/438-0468
SEWER DIST: LC WATER DIST: CA
DATE
INSPECTED: ?/q> APPROVED - DISAPPROVED k
INSPECTED
INSPECTED: q?]93 APPROVED DISAPPROVED -
INSPECTED DATE
BY: INSPECTED: APPROVED - DISAPPROVED -
FINAL BUILDING INSPECTION
DEPT: BUILDING ENGINEERING FIRE PLANNING U/M . WATER
PLAN CHECK#: CB920844 PERMIT#: CB920844 PROJECT NAME: 2006 SF + 406 SF GARAGE PLAN 1
PHASE 1
DATE: 04/28/93 PERMIT TYPE: SFD
ADDRESS: 2811 AVENIDA VALERA
CONTACT PERSON/PHONE#: ALLISON @ FIELDSTONE/438-0468 SEWER DIST: LC WATER DIST: CA
DATE
BY: INSPECTED: (-/?fg-c APPROVED I/ DISAPPROVED -
i
INSPECTED DATE BY: INSPECTED: APPROVED - DISAPPROVED -
INSPECTED DATE BY: INSPECTED: APPROVED - DISAPPROVED -
FINAL BUILDING INSPECTION
DEPT: BUILDING ENGINEERING FIRE . U/M
PLAN CHECK#: CB920844
f4’RMIT# : CB920844
L-AOJECT NAME: 2006 SF + 406 SF GARAGE PLAN 1
PHASE 1
ADDRESS: 2811 AVENIDA VALERA
CONTACT PERSON/PHONE#: ALLISON @ SEWER DIST: LC WATER DIST:
WATER
DATE: 04/28/93
PERMIT TYPE: SFD
FIELDSTONE/438-0468
CA
/
INSPECTED:
DATE
3 APPROVED - J DISAPPROVED - q)Jc INSPECTED
BY :
INSPECTED DATE
BY: INSPECTED : APPROVED - DISAPPROVED -
INSPECTED DATE
BY: INSPECTED: APPROVED - DISAPPROVED -
r c
FINAL BUILDING INSPECTION
DEPT: BUILDING ENGINEERING FIRE PLANNING U/M
PLAN CHECK#: CB920844 PERMIT#: CB920844 PROJECT NAME: 2006 SF + 406 SF GARAGE PLAN 1 PHASE 1
ADDRESS: 2811 AVENIDA VALERA
CONTACT PERSON/PHONE#: ALLISON @ FIELDSTONE/438-0468 SEWER DIST: LC WATER DIST: CA
WATER
DATE: 04/28/93
PERMIT TYPE: SFD
INSPECTED DATE
BY: INSPECTED : APPROVED - DISAPPROVED -
7
9 CITY OF CARLSBAD
INSPECTION REQUEST
PERMIT# CB920844 FOR 05/10/93 INSPECTOR AREA PY
DESCRIPTION: 2006 SF + 406 SF GARAGE PLAN 1 PLANCKf CB920844
PHASE 1 TYPE: SFD JOB ADDRESS: 2811 AVENIDA VALERA APPLICANT: FIELDSTONE/LA COSTA ASSOC.
CONTRACTOR: OWNER:
REMARKS : BJN/ALLISON/Q 3 8 -04 68
SPECIAL INSTRUCT:
TOTAL TIME:
CD LVL DESCRIPTION ACT
19 ST Final Structural A 29 PL Final Plumbing 39 EL Final Electrical 49 ME Final Mechanical
.DATE 031793 031593 031193 031193 031093 031093 030893 030893 030193 022393 021893 021193 020393 020293 012893 012893 012893 012693 010593 101992 092192
OCC GRP R3/M1
CONSTR. TYPE VN
STE : LOT: 126 PHONE: 619 546-8226
PHONE:
PHONE: A) m INSPECTOR
COMMENTS
***** INSPECTION HISTORY *****
DESCRIPTION Gas/Test/Repairs Gas/Test/Repairs
Interior Lath/Drywall Gas/Test/Repairs Interior Lath/Drywall Gas/Test/Repairs Exterior Lath/Drywall Interior Lath/Drywall Insulation Rough Combo Rough Combo Rough/Topout Shear Panels/HD's Shear Panels/HD's Roof/Reroof Rough/Topout Insulation Roof/Reroof Roof/Reroof Ftg/Foundation/Piers
Underground/Under Floor
ACT INSP COMMENTS
AP PY NR PY CA PY
CA PY
AP PY NR PY
AP PY
AP PY AP PY co PY NR PY AP PY
NS PY AP PY co PY co PY AP PY NS PY AP MP AP MP
NRMP
DRAFT STOP @ FIREPLACE
EXT SHEAR ONLY OK TO WRAP
LEAK AT BATHRWH
438-3550
A
CITY OF CARLSBAD * *NOTICE
BUILDING DEPARTMENT 2075 LAS PALMAS DRIVE
i
FOR INSPECTION CALL 438-3101. RE-INSPECTION FEE DUE? YES
1. PHONE
~ CODEENFORCEMENTOFFICER
C9';FRINY &'f>Wb' PERF,7RUFCt
ryIlIrH nFQt!lEJFD APPPC JAL PY
TME SFFCIAI. ItJSPE'_T"" C'F
' FIELDSTONE COMPANY
row^^. DOING REPOR~EO WOPK 1/2" 8, 7 STRAND, 270 KSI CABLE, MIX #6525,
GLLJE - LAM. FABRICI)F:O% QEINFOPCED CONCRETE STRUCT. STEEL ASSEMBLY x PPE-5TRFSSEC CONCRETE REINFORCED GYPSUM OTHER
r) F I N C 9PC F D MASON &7 Y PILE DRIVING
MUELLER.LEWIS CONCRETE
LAB. RECEIVING & TESTING CONSTR. &,!AT':. SAC!OLE~
GAUGE 6C826, GAUGE NC8105
INSP'N.
DATE -
_.
I P.R.I., INC. ---- -.
C9CATIONS OF WORK INSPECTED. TEST SAMPLES TAKEN, WORK REJECTED, JOB PROBLEMS. PROGRESS. REMARKS, ETC.
t*ICL'>@ES l>JFORhlA rlOI4 AROLJ r - AEAOI.JNTf OF MITERIAL FLACEO OR YIORV PERFORhlED: PJUIABER. TYPE. 6 IDE'I 7.*10'5.
qT TFST SL~IP!.C~ TnrFrl. 51 RbJCT. C@*I~IECTlONS I'NF.L.CS *.lbPF. L4.T. BOLTS TORQUED! CHECKECI: ETC.
The post tension concrete work requiring special inspection was,
to the best of my knowledge, in conformance with the approved
plans and specifications and the applicable workmanship provisions
Lot -12
13
# 4
#5
#6
t7
#8
# 9
# 10
111
112
#13
514
815
#16
#17
of the Uniform Building Code,
13 thru 11.
3203 Sitio Rosalia
3207 Sitio Rosalia
3212 Sitio Rosalia
3208 Sitio Rosalia
3204 Sitio Rosalia
2808 Avenida Valera
2810 Avenida Valera
2812 Avenida Valera
2814 Avenida Valera
2816 Avenida Valera
2818 Avenida Valera
2820 Avenida Valera
2822 Avenida Valera
2826 Avenida Valera
2828 Avenida Valera
2830 Avenida Valera
CB920-840
CB920-848
CB920-855
CB920-859
CB920-849
CB920-841
CB920-836
CB920-860
CB9 20-850
CB9 2 0- 8 6 1
CB920-843
CB920-837
CB920-862
CB920-851
CB920-863
CB920-864
1988 Edition. Inspection reports
Lot #lo9
PllO
ill1
#112
1113
8114
#llS
5116
#117 #118
..a .R+M
#127
5128
#129
6130
2825 Vista Mariana CB920-839
2823 Vista Mariana CB920-866
2821 Vista Mariana CB920-844
2817 Vista Mariana CB920-854
2815 Vista Mariana CB920-834
2811 Vista Mariana CB920-857
2809 Vista Mariana CB920-846
2807 Vista Mariana CB920-858
2805 Vista Mariana CB920-835
2803 Vista Mariana CB920-847
2811 Avenida Valera CB920-845
2813 Avenida Valera CB920-853
2815 Avenida Valera CB920-838
2817 Avenida Valera CB920-865
2819 Avenida Valera CB920-852
28 Day Compression test that did not reach the required PSI
Lot #3 - 2940 - 45 Days
16 - 2970 - 60 Days
Remaining lots did meet required PSI. /H Z#Q&.
DALE REGLI
REGISTERE0 'NSDFC -3F
4/12/93 280
DATE OF REPORT :E; <-E? .;....s<
PROFESSIONAL REGISTER INSPECTIONS, INC,
7895 Convoy Court #15
San Diego, Ca. 92111 -JOB NO.: 491 1
JOB: FAIRWAYS
ADDRESS: 2811 AVENI@A VAtERA
OWNER: FIELOSTONE COMPANY CONTRACTOR: MUELLEI? LEWIS CQNCRETE
CLIENT: MUELLER LEWIS CQNCRETE ENGINEER : JEM I11
ARCHITECT: BERKUS GROUP BLDG AUTH:. CITY OF CARLSBAO
INSPECTOR: .JEFFREY GAYLER PERMIT NO.: CB92-084.5 PLAN FILE:
FIELD
SAMPLE OF: CONCRETE
LOCATION OF SPECIMEN
IN JOB OR STRUCTURE: LOT ti26
MIX NO.: 6525 MADE BY: JEFFREY GAYLER
PROPORTIONS: SLUMP: 5 "
ADMIXTURE: DATE MADE: 1 0/ 19/92
TYPE OF CEMENT: I1 DATE RECEIVED: 10/22/92
CONC. SUPP,LIER: NELSON & SLOAN SOURCE OF ROCK:
TICKET NO.: 403901 INSPECTOR SIGN:
LABORATORY TEST DATA
7 @AYS 10 DAYS 28 DAYS 28 DAYS
SPECIMEN MARKINGS: 928 14 92% 15 92816
DATE TESTED: 10/29 11/16 11/16
ULTIMATE LOAD-LBS: 57000
v UNIT STRESS-LBS: t 2030
SPECIFIED STRENGTH
AT 28 DAYS-PSI:
D I STR IB UTION : M II E L L E R L E W I S C ON C R E T E
F I E L D S 7 ON E C OM PAN Y
JEM I11
CITY OF CARLSBAO
.
2500
. .
ENGINEER
7895 Convoy Court San Diego, California 9211 1 PROFESSIONAL REGISTERED INSPECTIONS, I INC. -- ~ Phone 292-066
INSPECTORS WEEKLY REPORT +d I NO.+r// I ENDING FOR WEEK ON .. L~~...z..z.............. 192
I
COVERING WORK PERFORMED 3 REINFORCED CONCRETE 0 STRUCT. STEEL ASSEMBLY 0 GLUE - LAM. FABRICATION
wnicn REoUiREo APPROVAL BY ~PRE-STRESSED CONCRETE 0 REINFORCED GYPSUM 0 OTHER
TnE SPECIAL INSPECTOR OF u REINFORCEO MASONRY 0 PILE DRIVING ....................................................
JOB ADDRSJJ
OWNER OR PROJECT NAME
LAD. RECEIVlN&b 1-EJTINQ CONSTR. MAT'L. SAMPLES I /
~~
INSP'N. LOCATIONS OF WORK INSPECTED. TEST SAMPLES TAKEN. WORK REJECTED, JOB PROBLEMS, PROGRESS: REMARKS ETC.
DATE INCLUDES INFORMATION ABOUT - AMOUNTS OF MATERIAL PLACE0 OR WORK PLRCORMLO: NUMBER. TYPE. b lDLNT.NO*S.
OF TLST SAMPLES TAKEN: STRUCT. CONNeCTlONS (WELDS MADE. H.T. BOLTS TOROULD) CW(ECKL0: ETC.
DATE OF REPORT REGISTER NUMB'TR - I ..
PROFESSIONAL REGISTERED INSPECTIONS, INC.
7895 Convoy Court tl5
San Diego, Ca. 92111 JOB NO,: 491 1
J08 ADDRESS: AYENIDA YALERA ARCHITECT: LQRIMAR & CASE
.............................................................................
JOB NAME: FAIRWAYS ENGINEER: JEM I11
BL@G AUTH: CITY QF CARLS5.A.E GEN CONTRACTOR: FIELESTONE CQMPANV
CONSTR. MAT'L: FQST TENSIQN STRESSING CONTRACTOR: Jaw, STEEL
PLAN FILE:
@ESCRIBE MAT'L: 1/2" I?IP.., 270 KSI CABLES, QNIT #C826
INSPECTION REPORT
: 11/06 Witnessed the stressing of post tension cables in slab on grade
for lots #126 thru 139, Gbcet-ved stressing pressure and verified
elon(3ation achieved. WorBk was perfor.med in accordance with the
appvoved plans anc! 5peci.f ications,
Lot 0126 281 1 Avenida Valera CB92-081.15
#127 2813 Avenida Valet-a C592-0853
#128 2815 Avenida Valera C892-9838
#129 2817 .4venide Valera CB92-0865
#I30 2819 Avonida Valer'a CB92-0852
: [?ALE REGL? S!!PERVISOR
INSPECTOR
2 11/09/92 : 280
DATE REGISTER #
INCOBPOBATED
FOUNDATION OBSERVATION REPORT
FOUNDATION LOCATION (if not entire building)
0 ADDITIONAL OBSERVATION REQUIRED PERMIT NO.: PLAN FILE NO.: I I I& SUBSTANTIAL CONFORMANCE
~~ 0 PURPOSE OF OBSERVATION El Verify soil conditions exposed are similar to those anticipated. 7 Verify footing excavations extend to minimum depth recommended in soil report.
0 Verify foundation reinforcement complies with minimum recommended in soil report.
0 Verify slab reinforcement, sand bedding and moisture barrier comply with minimum
recommended in soil report. -
I */ f :, ,f. &l, 0 Other: I, ,. 1 J,.,I
!'a ' ' /
7.. P- 0 APPLICABLE SOIL REPORT: TITLE: - ,2 ,' / ud ,,- ; , , ,,r- R,/IJh+ 2
0 SOIL REPORT RECOMMENDATIONS BASED ON
rcI L.) I DA~: 7-d 24, OL
W
Expansion Condition; 0 VERY LOW 0 LOW EMEDIUM aHIGH 0 VERY HIGH B FillGeometry
0 Other:
FootingDepth: E712lNc~E.S ~XUINCHES O%INCHES OTHER: Footing Reinforcement: 0 NO. 4 T&B 0 ZN0.4 T&B 0 N0.5 T&B OTHER 9F
Interior Slab Reinforcement: 0 ~10/10 0 W/6 0 NO. 3 @ 24 INCHES ' 0 No. 3 @ is INCHES Slab Bedding Material and Thickness: Foundation Width:
If yes, identify and descrik
Auhtantial mniimmce with ail Report (see n-ose of Otxwrvation").
0 Substantial codmnancc with Foundation Plans.
0 MINIMUM FOUNDATION RECOMMENDATION
Vapor Barrier:
0 FOUNDATION PLAN REVIEWED: YES0 NO g,
0 OB ERVATIONS:
0 Other:
0 COMMENTS:
PROFESSIONAL REGISTER INSPECTIONS, INC,
7895 Convoy Court #lS
San Diego, Ca. 92111 JOB NO. : 491 1
JOB: FAIRWAYS
ADDRESS : 28 11 AVENIDA V.4LEP.A
OWNER: FIELOSTONE COMPANY CONTRACTOR: MUELLEE LEWIS CONCRETE
CLIENT: MUELLEF! LEWIS CQNCEETE ENGINEER: JEM 111:
ARCHITECT: BERKUS GROUP
INSPECTOR: JEFFREY GAYLER
FIELD
SAMPLE OF: CONCRETE
MIX NO.: 6525
PROPORTIONS:
ADMIXTURE:
TYPE OF CEMENT: I1
CONC. SUPPLIER: NELSON & SLQAN
TICKET NO.: 40390 1
8LDG AUTH: CITY OF CARLSBAO
PERMIT NO,: C892-0845 PLAN FILE:
LOCATION OF SPECIMEN
IN JOB OR STRUCTURE: LOT #126
MADE BY: 3EFFREY GAYLER
SLUMP: 5 "
DATE MADE: 1 0/ 19/92
DATE RECEIVED: 10/22/92
SOURCE OF ROCK:
INSPECTOR SIGN:
LABGRATORV TEST DATA
7 DAYS 18 DAYS 28 DAYS 28 DAYS
SPECIMEN MARKINGS:
DATE TESTED:
AREA-SQsIN.:
ULTIMATE LUAD-LBS:
UNIT STRESS-LBS:
SPECIFIED STRENGTH
AT 28 DAYS-PSI:
.
DISTRIBUTION: MQELLER LEWIS CQNCRETE
FIELOSTONE COMPANY
CITV OF CARLSGAD
JEM I11
928 14 928 15 928 16
1 0/29 11/16 11/16
28.28 20.28 28.28
57000 75500 76500
: 2030 : 2670 : 27 1.0
2500
ENGINEER