HomeMy WebLinkAbout2815 ELMWOOD ST; ; CB004606; Permit06/27/2001
Job Address:
Permit Type:
Parcel No:
Valuation:
Occupancy Group:
# Dwelling Units:
Bedrooms:
Project Title:
City of Carlsbad
1635 Faraday Av Carlsbad, CA 92008
Residential Permit Permit No:CB004606
Building Inspection Request Line (760) 602-2725
2815 ELMWOOD ST CBAD
RESDNTL
1562304500
$34,986.00
0
0
Sub Type:
Lot#:
Construction Type:
Reference #:
Structure Type:
Bathrooms:
RAD
0
VN
COURSON RES-357 SF BED ADDITIO
Status:
Applied:
Entered By:
Plan Approved:
Issued:
Inspect Area:
Orig PC#:
Plan Check#:
ISSUED
12/06/2000
RMA
06/27/2001
06/27/2001
Applicant:
GONSALEZ THOMAS L&COURSON KELLY
2815 ELMWOOD ST
CARLSBAD CA 92008
Owner:
GONSALEZ THOMAS L&COURSON KELLY
2815 ELMWOOD ST
CARLSBAD CA 92008
3232 Od/2?/Oi 0002 01
Total Fees: $629.92 Total Payments To Date: $200.09 Balance Due: $429.83
Building Permit
Add'l Building Permit Fee
Plan Check
Add'l Plan Check Fee
Plan Check Discount
Strong Motion Fee
Park in Lieu Fee
Park Fee
LFM Fee
Bridge Fee
Other Bridge Fee
BTD #2 Fee
BTD #3 Fee
Renewal Fee
Add'l Renewal Fee
Other Building Fee
Pot. Water Con. Fee
Meter Size
Add'l Pot. Water Con. Fee
Reel. Water Con. Fee
$307.83 Meter Size
$0.00 Add'l Reel. Water Con. Fee
$200.09 Meter Fee
$0.00 SDCWA Fee
$0.00 CFD Payoff Fee
$3.50 PFF
$0.00 PFF (CFD Fund)
$0.00 License Tax
$0.00 License Tax (CFD Fund)
$0,00 Traffic Impact Fee
$0.00 Traffic Impact (CFD Fund)
$0.00 Sidewalk Fee
$0.00 PLUMBING TOTAL
$0.00 ELECTRICAL TOTAL
$0.00 MECHANICAL TOTAL
$0.00 Housing Impact Fee
$0.00 Housing InLieu Fee
Master Drainage Fee:
$0.00 Sewer Fee:
$0.00 Additional Fees:
TOTAL PERMIT FEES
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$77.00
$20.00
$21.50
$0.00
$0.00
$0.00
$0.00
$0.00
$629.92
Inspecto,Date:Clearance:
NOTICE: Please take NOTICE that approval of your project includes the "Imposition of fees, dedications, reservations, or other exactions hereafter collectively
referred to as lees/exactions.' You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must
follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for
processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack,
review, set aside, void, or annul their imposition.
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capactiy
changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project NOR DOES IT APPLY to any
fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitations has previousjy_otherwise expired.
PERMIT APPLICATION
CITY OF CARLSBAD BUILDING DEPARTMENT
1635 Faraday Ave., Carlsbad, CA 92008
FOR OFFICE USE ON
PLAN CHECK NO.
EST. VAL. .
Plan Ck. Deposit
Validated By
Date
Address (include Bldg/Suite #)Business Name (at this address)
Legal Description Lot No.
Assessor's Parcel # A __ E;
/. \ A A T C ~"7 I
Description of Work I , ' 'f"5*" t ' rf'i^rnaae-^^vA oe^noov^
&^i"'JftB^
Subdivision
.*ting Use
JSO. FT.
**&-*••
Name/Number
#of Stories
,,,:,,4. ,,-,..,,
Ugi*)Nty. 12/ogh**
Proposed Use
# of Bedrooms
ft N0£ ;;, r,o -Total # ofrunits
# of Bathrooms
Name Address State/Zip Telephone # Fax #
' State/Zip Telephone »
State/Zip Telephone #
(Sec. 7031 .5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its
issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law
(Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code] or that he is exempt therefrom, and the basis for the alleged
exemption. Any violation of Section 7031 .5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars 15500]).
Name Address
State License # License Class
Designer Name Address
State License #
City State/Zip Telephone #
City Business License #
City State/Zip Telephone
Workers' Compensation Declaration: I hereby affirm under penalty of perjury one of the following declarations:
Q \ have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance
of the work for which this permit is issued.
Q I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is
issued. My worker's compensation insurance carrier and policy number are:
Insurance Company _ Policy No. _ Expiration Date _
(THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS [$100] OR LESS)
Qjx^CERTIFICATE OF EXEMPTION: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as
to become subject to the Workers' Compensation Laws of California.
WARNING: Failure to secure workers' compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred
thousand dollars {$10p?OOQ}, in addition to the cost of compensation, damages as provided for in Section 3706 of the Labor code, interest and attorney's fees.
SIGNATURE es&ffi ( J^M.X^/V-W^^ _ DATE~~~~
the Labor code, intere
) 2-j Lf / <V ")
I hereby affirm that I am exempt from the Contractor's License Law for the following reason:
O l< as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale
(Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does
such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is
sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale).
fyT as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The
Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed
pursuant to the Contractor's License Law).
Q I am exempt under Section _ Business and Professions Code for this reason:
YES Qflo1 . I personally plan to provide the major labor and materials for construction of the proposed property improvement.
2. \ I (have?) have not) signed an application for a building permit for the proposed work.
3. I have contracted with the following person (firm) to provide the proposed construction (include name / address / phone number / contractors license number):
4. I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone
number / contractors license number): ^ ^ _
5. I will provide some of the work, but liiave contracted (hired) the following persons to provide the work indicated (include name / address / phone number / type
of work}:_ _ J ^^^L ^ _-_ —
£
Is the applicant or future building occupanjjdquired to submit a business plan, acutely hazardous materials registration form or risk management and prevention
program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? Q YES Q NO
Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? O YES Q NO
Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? Q YES Cl NO
IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE
REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT.
I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097(i) Civil Code).
LENDER'S NAME LENDER'S ADDRESS
I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all
City ordinances and State laws relating to building construction. I hereby authorize representatives of the CitV of Carlsbad to enter upon the above mentioned
property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES,
JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT.
OSHA: An OSHA permit is required for excavations over 5'0" deep and demolition or construction of structures over 3 stories in height.
EXPIRATION: Every permit issued by we building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work
authorized by such permit is not commenced withirx180 days from the date of such permit or if the building or work authorized by such permit is suspended or abandoned
at any time after the work is comrpenc«l fw a pgficMl of 180 days (Section 106.4.4 Uniform Building Code).
APPLICANT'S SIGNATURE DATE
WHITE; File YELLOW: Applicant PINK: Finance
City of Carlsbad Bldg Inspection Request
For: 09/27/2002
Permit# CB004606
Title: COURSON RES-357 SF BED ADDITIO
Description:
Inspector Assignment: PS
Type:RESDNTL Subtype: RAD
Job Address: 2815 ELMWOOD ST
Suite: Lot 0
Location:
APPLICANT GONSALEZ THOMAS L&COURSON KELLY
Owner: GONSALEZ THOMAS L&COURSON KELLY
Remarks:
Phone: 7607297758
Inspector:
Total Time:
CD Description
19 Final Structural
29 Final Plumbing
39 Final Electrical
49 Final Mechanical
Requested By: KELLY
Entered By: KAREN
Associated PCRs/CVs
Inspection History
Date Description
08/13/2002 89 Final Combo
01/07/2002 89 Final Combo
09/28/2001 16 Insulation
09/28/2001 17 Interior Lath/Drywall
09/28/2001 18 Exterior Lath/Drywall
09/28/2001 23 Gasn"est/Repairs
09/14/2001 84 Rough Combo
08/09/2001 13 Shear Panels/HD's
08/09/2001 15 Roof/Reroof
07/30/2001 14 Frame/Steel/Bolting/Welding
07/17/2001 11 Ftg/Foundation/Piers
Act
CO
CA
AP
AP
AP RC
WC RC
AP RC
NR RC
AP RC OK TO COVER
PA RC CHECKED UNDERFLOOR CONSTR. OK TO SHEATH FLOOR &
CONTINUE
AP RC OK TO POUR
Insp Comments
PS SEE NOTICE ATTACHED
RC
RC
RC
OK TO WRAP, OK TO INSULATE
City of Carlsbad Bldg Inspection Request
For: 08/13/2002
Permits CB004606
Title: COURSON RES-357 SF BED ADDITIO
Description:
Inspector Assignment: RGB
Sub Type: RAD
2815 ELMWOODST
Lot
Type: RESDNTL
Job Address:
Suite:
Location:
APPLICANT GONSALEZ THOMAS L&COURSON KELLY
Owner: GONSALEZ THOMAS L&COURSON KELLY
Remarks: AM PLEASE
Phone: 7607297758
Inspector:
Total Time:
CD Description
19 Final Structural
29 Final Plumbing
39 Final Electrical
49 Final Mechanical
Requested By: NA
Entered By: CHRISTINE
Associated PCRs/CVs
Date
01/07/2002
09/28/2001
09/28/2001
09/28/2001
09/28/2001
09/14/2001
08/09/2001
08/09/2001
07/30/2001
Inspection History
Description Act Insp Comments
CA RC
AP RC
AP RC
AP RC
WC RC
AP RC OK TO WRAP, OK TO INSULATE
NR RC
AP RC OK TO COVER
PA RC CHECKED UNDERFLOOR CONSTR. OK TO SHEATH FLOOR &
CONTINUE
AP RC OK TO POUR
89 Final Combo
16 Insulation
17 Interior Lath/Drywall
18 Exterior Lath/Drywall
23 Gas/Test/Repairs
84 Rough Combo
13 Shear Panels/HD's
15 Roof/Reroof
14 Frame/Steel/Bolting/Welding
07/17/2001 11 Ftg/Foundation/Piers
CITY OF CARLSBAD
BUILDING DEPARTMENT
NOTICE (760) 602-2700
1635 FARADAY AVENUE
DATE O Z~TIME
PERMIT NO.
FOR INSPECTION CALL (760) 602-2725. RE-INSPECTION FEE DUE? L YES
-ORI^IATION/CONTACT _
PHONE
BUILDING INSPECTOR CODE ENFORCEMENT OFFICER
EsGil Corporation
In Partners/lip with, government for 'Bidding Safety
DATE: March 2O, 2001 Q AEH4CANT
JURISDICTION: Carlsbad Q PLAN REVIEWER
Q FILE
PLAN CHECK NO.: 00-4606 SET: II
PROJECT ADDRESS: 2815 Elmwood St.
PROJECT NAME: Gonsalez / Courson Residence Addition
XI The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes.
The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff.
The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
The check list transmitted herewith is for your information. The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck.
The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
The applicant's copy of the check list has been sent to:
XI Esgil Corporation staff did not advise the applicant that the plan check has been completed.
Esgil Corporation staff did advise the applicant that the plan check has been completed.
Person contacted: Telephone #:
Date contacted: (by: ) Fax #:
Mail Telephone Fax In Person
REMARKS:
By: Bill Elizarraras Enclosures: Title 24 calc's
Esgil Corporation
D GA D MB D EJ D PC 3/13/01 trnsmtl.dot
9320 Chesapeake Drive, Suite 208 4- San Diego, California 92123 4 (858)560-1468 4 Fax (858) 560-1576
EsGil Corporation
In ^Partnership with government for $ui(t(ing Safety
DATE: December 20, 2000 a APPLICANT
JURISDICTION: Carlsbad a PLAN REVIEWER
a FILE
PLAN CHECK NO.: 00-4606 SET: I
PROJECT ADDRESS: 2815 Elmwood St.
PROJECT NAME: Gonsalez / Courson Residence Addition
The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes.
The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff.
The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
XI The check list transmitted herewith is for your information. The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck.
The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
XI The applicant's copy of the check list has been sent to:
Kelly Courson
2815 Elmwood St. Carlsbad, CA. 92008
Esgil Corporation staff did not advise the applicant that the plan check has been completed.
Esgil Corporation staff did advise the applicant that the plan check has been completed.
Person contacted: Kelly Courson (\'u) Telephone #: 760-729-7758
Date contacted: 'tl.2. 'ot (by:^ ) Fax #:
Mail i_-"'Telephone „/ Fax In Person
REMARKS:
By: Bill Elizarraras Enclosures:
Esgil Corporation
D GA D MB [H EJ D PC 12/11/00 trnsmtl.dot
9320 Chesapeake Drive, Suite 208 * San Diego, California 92123 4 (858)560-1468 4- Fax (858) 560-1576
Carlsbad 00-4606
December 20, 2000
PLAN REVIEW CORRECTION LIST
SINGLE FAMILY DWELLINGS AND DUPLEXES
PLAN CHECK NO.: 00-46O6 JURISDICTION: Carlsbad
PROJECT ADDRESS: 2815 Elmwood St.
FLOOR AREA: 357 sqft. Dwelling Add'n STORIES: 1
REMARKS:
DATE PLANS RECEIVED BY
JURISDICTION:
DATE INITIAL PLAN REVIEW
COMPLETED: December 20, 2000
HEIGHT: 18'
DATE PLANS RECEIVED BY
ESGIL CORPORATION: 12/11/00
PLAN REVIEWER: BUI Elizarraras
FOREWORD (PLEASE READ):
This plan review is limited to the technical requirements contained in the Uniform Building Code,
Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws
regulating energy conservation, noise attenuation and access for the disabled. This plan review
is based on regulations enforced by the Building Department. You may have other corrections
based on laws and ordinance by the Planning Department, Engineering Department, Fire
Department or other departments. Clearance from those departments may be required prior to
the issuance of a building permit.
Present California law mandates that residential construction comply with the 1998 edition of
the California Building Code (Title 24), which adopts the following model codes: 1997 UBC,
1997 UPC, 1997 UMC and 1996 NEC (all effective 7/1/99).
The above regulations apply to residential construction, regardless of the code editions adopted
by ordinance.
The following items listed need clarification, modification or change. All items must be satisfied
before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3,
1997 Uniform Building Code, the approval of the plans does not permit the violation of any
state, county or city law.
To speed up the recheck process, please note on this list (or a copy) where each
correction item has been addressed, i.e.. plan sheet number, specification section, etc.
Be sure to enclose the marked up list when you submit the revised plans.
Carlsbad OO-4606
December 20, 2000
• PLANS
1. Please make all corrections on the original tracings, as requested in the
correction list. Submit three sets of plans for commercial/industrial projects (two
sets of plans for residential projects). For expeditious processing, corrected sets
can be submitted in one of two ways:
1. Deliver all corrected sets of plans and calculations/reports directly to the City of
Carlsbad Building Department, 1635 Faraday Ave,, Carlsbad, CA 92008, (760)
602-2700. The City will route the plans to EsGil Corporation and the Carlsbad
Planning, Engineering and Fire Departments.
2. Bring one corrected set of plans and calculations/reports to EsGi! Corporation,
9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468.
Deliver all remaining sets of plans and calculations/reports directly to the City of
Carlsbad Building Department for routing to their Planning, Engineering and Fire
Departments.
NOTE: Plans that are submitted directly to EsGil Corporation only will not be
reviewed by the City Planning, Engineering and Fire Departments until review by
EsGil Corporation is complete.
2. Plans, specifications and calculations shall be signed and sealed by the
California State licensed engineer or architect responsible for their preparation,
for plans deviating from conventional wood frame construction. Specify
expiration date of license. (California Business and Professions Code).
• GENERAL RESIDENTIAL REQUIREMENTS
3. Sleeping rooms shall have a window or exterior door for emergency escape. Sill
height shall not exceed 44" above the floor. Windows must have an openable
area of at least 5.7 square feet with the minimum openable width 20" and the
minimum openable height 24". The emergency door or window shall be
openable from the inside to provide a full, clear opening without the use of
separate tools. Section 310.4. @ Office
• ROOFING
4. Specify roof material and application. Chapter 15.
• FOUNDATION REQUIREMENTS
5. The following footing requirements shall apply in Seismic Zones 3 and 4, per
Section 1806.7:
a) Foundations with stemwalls shall be provided with a minimum of one No.
4 bar at the top of the wall and one No. 4 bar at the bottom of the footing.
Carlsbad 00-4606
December 20, 2000
6. Dimension foundations per U.B.C. Table 18-l-C:
Floors Footing
Supported* Thickness Width Depth Stemwall
1 6" 12" 12" 6"
7. The following anchor bolt requirements shall apply in Seismic Zones 3 and 4, per
Section 1806.6.1:
a) Plate washers (minimum size of 2" x 2" x 3/16") shall be used on each
anchor bolt.
8. Note on plan that hold down anchors must be tied in place prior to foundation
inspection. Section 108.5.2.
9. Show minimum 18" clearance from grade to bottom of floor joists and minimum
12" clearance to bottom of girders. Section 2306.3.
10. Show minimum underfloor ventilation equal to 1 sq. ft. for each 150 sq. ft. of
underfloorarea. Openings shall be as close to corners as practical and shall
provide cross ventilation on at least two approximately opposite sides. Section
2306.7.
• FRAMING
11. Show nailing will be in compliance with Table 23-I1-B-1. (Code Update)
12. Provide calculations for main vertical and horizontal framing members and
footings. Section 106.3.3. (This applies to roof P-LAM Beams)
i
13. Specify new beam size over bathroom area.
14. Show the following on the plans for the required braced wall panels. If the
requirements of braced wall panels in conventional light frame construction are
not possible, provide design calculations from a licensed Engineer or Architect.
a) Show on the plans the location, length and type of braced wall panel as
per UBC Section 2320.11.3 and Table 23-IV-C-1.
i) Braced wall panels shall start at not more than 8' from each end of
a braced wall line.
b) Interior braced wall panels shall extend to the roof or floor diaphragm
level.
c) Show lateral requirements for existing wall common to new Addition and
existing structure.
Carlsbad 00-4606
December 20, 2000
d) Any braced wall panel required by Section 2320.11.3 may be replaced by
an alternate braced wall panel. UBC Section 2320.11.4. For alternate
braced wall panels in one story buildings, show compliance with the
following on the plans:
i) Minimum braced panel length is 2'-8" in width and a maximum
height of 10'-0".
ii) Each braced wall panel is sheathed on at least one face with 3/8"
plywood sheathing nailed with 8d common or galvanized box nails
per23-ll-B-1 and blocked at all plywood edges,
iii) A minimum of two anchor bolts installed in accordance with
Sectionl806.6 between hold down devices,
iv) An approved hold down device fastened to the foundation and
capable of providing an uplift capacity of not less than 1,800
pounds is provided at each panel end.
v) The foundation that supports the braced panels is continuous
across the entire length of the braced wall line and reinforced with
a minimum of one # 4 bar top and bottom.
• ELECTRICAL (NATIONAL ELECTRICAL CODE)
»*.
15. Note on the plans that bathroom receptacle outlets shall be supplied by a
minimum of one 20-ampere branch circuit. Such circuits shall have no other
outlets. This circuit may serve more than one bathroom. NEC Art. 210-52(d).
• MISCELLANEOUS
To speed up the review process, note on this list (or a copy) where each correction item
has been addressed, i.e., plan sheet, note or detail number, calculation page, etc.
Please indicate here if any changes have been made to the plans that are not a result
of corrections from this list. If there are other changes, please briefly describe them and
where they are located in the plans.
• Have changes been made to the plans not resulting from this correction list?
Please indicate:
Yes G No a
The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake
Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to
perform the plan review for your project. If you have any questions regarding these plan
review items, please contact Bill Elizarraras at Esgi! Corporation. Thank you.
Carlsbad 00-4606
December 20, 2000
VALUATION AND PLAN CHECK FEE
JURISDICTION: Carlsbad
PREPARED BY: Bill Elizarraras
BUILDING ADDRESS: 2815 Elmwood St.
PLAN CHECK NO.: 00-4606
DATE: December 20, 2000
BUILDING OCCUPANCY: R3 TYPE OF CONSTRUCTION: VN
BUILDING
PORTION
Dwelling
Air Conditioning
Fire Sprinklers
TOTAL VALUE
Jurisdiction Code
AREA
( Sq. Ft.)
357
cb
Valuation
Multiplier
City Estimate
By Ordinance
i
Bldg. Permit Fee by Ordinance w
Reg.
Mod.
VALUE ($)
34,986
t
34,986
34,986
307.83
Plan Check Fee by Ordinance
Type of Review:
Repetitive Fee
Repeats
Complete Review D Structural Only
D Other
D Hourly
Esgil Plan Review Fee
Comments:
200.09
160.07
Sheet 1 of 1
macvalue.doc
BUILDING PLANCHECK CHECKLIST
DATE:PLANCHECK NO.: CB Qy
BUILDING AcfoR^SS: ___
PROJECT DESCRIPTION:
ASSESSOR'S PARCEL NUMBER: /c5fe -JJ3& *EST. VALUE:
ENGINEERING DEPARTMENT
APPROVAL
The item you have submitted for review has been
approved. The approval is based on plans,
information and/or specifications provided in your
submittal; therefore any changes to these items after
this date, including field modifications, must be
reviewed by this office to insure continued
conformance with applicable codes. Please review
carefully all comments attached, as failure to comply
with instructions in this report can result in
suspension of permit to build.
A Right-of-Way permit is required prior to
construction of the following improvements:
DENIAL
Please seev the, attached report of deficiencies
marked witruS^Make necessary corrections to plans
or specifications for compliance with applicable
codes and standards. Submit corrected plans and/or
specifications to this office for review.
Date:
Date:
Date:By:
By;
FOR OFFICIAL USE
ENGINEERING AUTHORIZATION TOISSUE BUILPING PERMIt;
Date:
Dedication Application
Dedication Checklist
Improvement Application
Improvement Checklist
Future Improvement Agreement
Grading Permit Application
Grading Submittal Checklist
Right-of-Way Permit Application
Right-of-Way Permit Submittal Checklist
and Information Sheet
Sewer Fee Information Sheet
ENGINEERING DEPT. CONTACT PERSON
Name: JOANNE JUCHNIEW1CZ
City of Carlsbad
Address: 1635 Faraday Avenue. Carlsbad, CA 92008
Phone: (760) 602-2775
CFD INFORMATION
Parcel Map No:
Lots:
Recordation:
Carlsbad Tract:
A-4
HAWORCWOCSUXKLSTtBuUIng Plsncheck CWst Font) (GMWrtO.doc
BUILDING PLANCHECK CHECKLIST
D
3RD
D
D
SITE PLAN
1. Provide a fully dimensioned site plan drawn to scale. Show:
F. Right-of-Way Width & Adjacent Streets
G. Driveway widths
H. Existing or proposed sewer lateral
I. Existing or proposed water service
J. Existing or proposed irrigation service
A. North Arrow
B. Existing & Proposed Structures
C. Existing Street Improvements
D. Property Lines
E. Easements
2. Show on site plan:
A. Drainage Patterns
1. Building pad surface drainage must maintain a minimum slope of one
percent towards an adjoining street or an approved drainage course.
2. ADD THE FOLLOWING NOTE: "Finish grade will provide a minimum positive
drainage of 2% to swale 5' away from building."
B. Existing & Proposed Slopes and Topography
C. Size, type, location, alignment of existing or proposed sewer and water service
(s) that serves the project. Each unit requires a separate service, however,
second dwelling units and apartment complexes are an exception.
D. Sewer and water laterals should not be located within proposed driveways, per
standards.
3. Include on title sheet:
A. Site address
B. Assessor's Parcel Number
C. Legal Description
For commercial/industrial buildings and tenant improvement projects, include:
total building square footage with the square footage for each different use,
existing sewer permits showing square footage of different uses (manufacturing,
warehouse, office, etc.) previously approved.
EXISTING PERMIT NUMBER DESCRIPTION
H:\WORCnDOCSO1KLSTBuHlng Plancheck Ctttt Form (Gwwric).doc
ND -ard
BUILDING PLANCHECK CHECKLIST
DISCRETIONARY APPROVAL COMPLIANCE
D 4a. Project does not comply with the following Engineering Conditions of approval for
Project No._ . _
D D D 4b. All conditions are in compliance. Date:
DEDICATION REQUIREMENTS
D D 5. Dedication for all street Rights-of-Way adjacent to the building site and any storm
drain or utility easements on the building site is required for all new buildings and
for remodels with a value at or exceeding $15.000. pursuant to Carlsbad
Municipal Code Section 18.40.030.
Dedication required as follows:
Dedication required. Please have a registered Civil Engineer or Land Surveyor
prepare the appropriate legal description together with an 8 1/z" x 11" plat map
and submit with a title report. All easement documents must be approved and
signed by owner(s) prior to issuance of Building Permit. Attached please find an
application form and submittal checklist for the dedication process. Submit the
completed application form with the required checklist items and fees to the
Engineering Department in person. Applications will not be accept by mail or fax.
Dedication completed by: Date:
IMPROVEMENT REQUIREMENTS
D D D 6a. All needed public improvements upon and adjacent to the building site must be
constructed at time of building construction whenever the value of the
construction exceeds $75.000. pursuant to Carlsbad Municipal Code Section
18.40.040.
Public improvements required as follows: ___
Attached please find an application form and submittal checklist for the public
improvement requirements. A registered Civil Engineer must prepare the
appropriate improvement plans and submit them together with the requirements
on the attached checklist to the Engineering Department through a separate plan
check process. The completed application form and the requirements on the
mWORCnDOCSCHKLST\BuikJing Ptmcheek CUst Frnm [RIDDLE - HARVEY 7-12-OO).doc
A ST o 3fd
D D D
n D-D
D
OD
na
D
n
ana
BUILDING PLAN
checklist must be
accepted. Improvement
and fees paid prior to i
submtted in person. Applications by mail or fax are not
jtans must be approved, appropriate securities posted
issuance of building permit.
Improvement Plans signe
6b. Construction of the public
Municipal Code Section
current grant deed on t
prepare the necessary Ni
must be signed, notarizi
Building permit.
Neighborhood Improvement Agreement will include the following:
6c. Enclosed please find your
agreement signed and no
Neighborhood Improvement Agreement. Please return
arized to the Engineering Department.
Neighborhood Improvement Agreement completed by:
Date:
6d. No Public Improvements
improvements found adiat
of the City Inspector prior
GRADING PERMIT REQUIREMENTS
The conditions that invoke
11.06.030 of the Municipal Coge
7a. Inadequate information av
requirements. Include
7b. Grading Permit required.
Engineer must be subletted
attached. NOTE: The
approval obtained prior to
Grading Inspector sign off
7c. Graded Pad Certification r
if a grading permit is not reuired
H:\WORO\DOCS\CHKLS'nBuIkJlno Plsncfwck CkUl Foon (RIDDLE - HARVEY 7-12-00).doc
;HECK CHECKLIST
by:Date:
improvements may be deferred pursuant to Carlsbad
8.40. Please submit a recent property title report or
e property and processing fee of $280 so we may
ghborhood Improvement Agreement. This agreement
d and approved by the City prior to issuance of a
required. SPECIAL NOTE: Damaged or defective
nt to building site must be repaired to the satisfaction
o occupancy.
he need for a grading permit are found in Section
accurate
ilable on Site Plan to make a determination on grading
grading quantities (cut, fill import, export).
A separate grading plan prepared by a registered Civil
together with the completed application form
uradino. Permit must be issued and rough grading
ssuance of a Building Permit.
by:Date:
quired. (Note: Pad certification may be required even
Rev. aaa/oo
1ST )ND >RD
D 12b.
BUILDING PLANCHECK CHECKLIST
• If owner/developer proposes a size other than the "standard", then
owner/developer must provide potable water demand calculations,
which include total fixture counts and maximum water demand in gallons
per minute (gpm). A typical fixture count and water demand worksheet is
attached. Once the gpm is provided, check against the "meter sizing
schedule" to verify the anticipated meter size for the unit.
• Maximum service and meter size is a 2" service with a 2" meter.
• If a developer is proposing a meter greater than 2", suggest the
installation of multiple 2" services as needed to provide the anticipated
demand, (manifolds are considered on case by case basis to limit
multiple trenching into the street).
Irrigation Use (where recycled water is not available)
All irrigation meters must be sized via irrigation calculations (in gpm) prior
to approval. The developer must provide these calculations. Please follow
these guidelines:
1. tf the project is a newer development (newer than 1998), check the recent
improvement plans and observe if the new irrigation service is reflected on
the improvement sheets. If so, at the water meter station, the demand in
gpm may be listed there. Irrigation services are listed with a circled T,
and potable water is typically a circled "W". The irrigation service should
look like:
STA 1+00 Install 2" service and
2.
1.5: meter (estimated 100 gpm)
If the improvement plans do not list the irrigation meter and the
service/meter will be installed via another instrument such as the building
plans or grading plans (w/ a right of way permit of course), then the
applicant must provide irrigation calculations for estimated worst-case
irrigation demand (largest zone with the farthest reach). Typically, Larry
Black has already reviewed this if landscape plans have been prepared,
but the applicant must provide the calculations to you for your use. Once
you have received a good example of irrigation calculations, keep a set for
your reference. In general the calculations will include:
• Hydraulic grade line
• Elevation at point of connection (POC)
• Pressure at POC in pounds per square inch (PSI)
• Worse case zone (largest, farthest away from valve
• Total Sprinkler heads listed (with gpm use per head)
• Include a 10% residual pressure at point of connection
3. In general, all major sloped areas of a subdivision/project are to be
irrigated via separate irrigation meters (unless the project is only SFD with
no HOA). As long as the project is located within the City recycled water
H:\WORD\DOCS\CHKLSTOuftllng Plsncheck CWsl Fwm (Genoric).doc
A ST pND 3RD
D
BUILDING PLANCHECK CHECKLIST
service boundary, the City intends on switching
services/meters to a new recycled water line in the future.
these irrigation
12c. Irrigation Use (where recycled water is available)
1 . Recycled water meters are sized the same as the irrigation meter above.-
2. If a project fronts a street with recycled water, then they should be
connecting to this line to irrigate slopes within the development. For
subdivisions, this should have been identified, and implemented on the
improvement plans. Installing recycled water meters is a benefit for the
applicant since they are exempt from paying the San Diego County Water
Capacity fees. However, if they front a street which the recycled water is
there, but is not live (sometimes they are charged with potable water until
recycled water is available), then the applicant must pay the San Diego
Water Capacity Charge. If within three years, the recycled water line is
charged with recycled water by CMWD, then the applicant can apply for a
refund to the San Diego County Water Authority (SDCWA) for a refund.
However, let the applicant know that we cannot guarantee the refund, and
they must deal with the SDCWA for this.
13. Additional Comments:
CT
o
PLANNING DEPARTMENT
BUILDING PLAN CHECK REVIEW CHECKLIST
Plan Check No. CB CO Address 32SV5 ST
Planner Greg Fisher
APN: V?le -
Phone (760) 602-4629
Add Net Project Density:.Type of Project & Use:
Zoning: ff — \ General Plan: T2.UV\ Facilities Management Zone:
DU/AC
I
CFD fin/nntl
Circle One
Date of participation:Remaining net dev acres:
{For non-residential development: Type of land used created by
this permit: }
Legend: [XJ Item Complete
Environmental Review Required:
DATE OF COMPLETION:
Item Incomplete - Needs your action
YES NO TYPE
Compliance with conditions of approval? If not, state conditions which require action.
Conditions of Approval:
Discretionary Action Required:
APPROVAL/RESO. NO.
PROJECT NO. ___
YES NO
DATE
TYPE
OTHER RELATED CASES:
Compliance with conditions or approval? If not, state conditions which require action.
Conditions of Approval:
Coastal Zone Assessment/Compliance
Project site located in Coastal Zone? YES _ NO _
CA Coastal Commission Authority? YES _ NO _
If California Coastal Commission Authority: Contact them at - 3111 Camino Del Rio North, Suite
200, San Diego CA 92108-1725; (619) 521-8036
Determine status (Coastal Permit Required or Exempt): _
Coastal Permit Determination Form already completed? YES _ NO _
If NO, complete Coastal Permit Determination Form now.
Coastal Permit Determination Log #: _
Follow -Up Actions:
1) Stamp Building Plans as "Exempt" or "Coastal Permit Required" (at minimum
Floor Plans).
2) Complete Coastal Permit Determination Log as needed.
H:\ADMIN\COUNTER\BldgPlnchkRevChklst
Inclusionary Housing Fee required: YES
(Effective date of Inclusionary Housing Ordinance - May 21, 1993.)
NO
Data Entry Completed? YES NO
(A/P/Ds, Activity Maintenance, enter CB#, toolbar. Screens, Housing Fees, Construct Housing Y/N, Enter Fee, UPDATE!)
Site Plan:
1. Provide a fully dimensional site plan drawn to scale. Show: North arrow,
property lines, easements, existing and proposed structures, streets, existing
street improvements, right-of-way width, dimensional setbacks and existing
topographical lines.
I | 2. Provide legal description of property and assessor's parcel number.
Zoning:
XJ 1. Setbacks:
Front:
^Interior Side:
Street Side:
Rear:
AX~ 2. Accessory structure" *Front:
Interior Side:
Street Side:
Rear:
Structure separation
^y^
\j\l\'\ I 3. Lot Coverage:
Required 5?6'
Required ^ '
Required — -
Required &O f
setbacks:
Required
Required
Required
Required
: Required \Q '
Required 40^
Shown <£? O
Shown <3 '
Shown
Shown 310'
Shown
Shown
Shown
Shown
Shown )0f
) Shown 5v%Vc)
4. Heiqht:Required 3?
5. Parking: Spaces Required
Guest Spaces Required
Additional Comments
Shown
Shown
Shown
> ^
T
OK TO ISSUE AND ENTERED APPROVAL INTO COMPUTER
H:\ADMIN\COUNTER\BldgPlnchkRevChklst
-DATE
D D D
D D
BUILDING PLANCHECK CHECKLIST
7d .No Grading Permit required.
7e. If grading is not required, write "No Grading" on plot plan.
MISCELLANEOUS PERMITS
8. A RIGHT-OF-WAY PERMIT is required to do work in City Right-of-Way and/or
private work adjacent to the public Right-of-Way. Types of work include, but are
not limited to: street improvements, tree trimming, driveway construction, tying
into public storm drain, sewer and water utilities.
Right-of-Way permit required for:
D D
D D
D D
D
9. INDUSTRIAL WASTE PERMIT If your facility is located in the City of Carlsbad
sewer service area, you need to contact the Carlsbad Municipal Water District,
located at 5950 El Camino Real, Carlsbad, CA 92008. District personnel can
provide forms and assistance, and will check to see if your business enterprise is
on the EWA Exempt List. You may telephone (760) 438-2722, extension 7153,
for assistance.
Industrial Waste permit accepted by:
Date:
10. NPDES PERMIT
Complies with the City's requirements of the National Pollutant Discharge
Elimination System (NPDES) permit. The applicant shall provide best
management practices to reduce surface pollutants to an acceptable level prior to
discharge to sensitive areas. Plans for such improvements shall be approved by
the City Engineer prior to issuance of grading or building permit, whichever
occurs first.
11, Q Required fees are attached
Of No fees required
WATER METER REVIEW
12a. Domestic (potable) Use
Ensure that the meter proposed by the owner/developer is not oversized.
Oversized meters are inaccurate during low-flow conditions. If it is oversized, for
the life of the meter, the City will not accurately bill the owner for the water used.
• All single family dwelling units received "standard" 1" service with 5/8" service.
H:\WORO\OOCS\CHKLSnBjMlng Ptonctw* Cktet Form (Generic).**
CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 1 CF-1R
Date..11/22/00 13:46:47
*v5.10********
Project Title COURSON / GONSALEZ
Project Address 2815 ELMWOOD STREE
CARLSBAD
Documentation Author... ROCKY
Salehi & Salehi Inc.
9636 Tierra Grande Street, Ste 206
San Diego, CA 92126
619-549-3680
Climate Zone 07
Compliance Method MICROPAS5 v5.10 for 1998 Standards by Enercomp, Inc.
Building Permit #
Plan ChecK / Date
Field ChecK/ Date
MICROPAS5 V5.10 File-N1122 Wth-CTZ07S92 Program-FORM CF-1R
User#-MP0406 User-Salehi & Salehi Inc. Run-S.F.R.
GENERAL INFORMATION
Conditioned Floor Area 357 sf
Building Type single Family Detached
Construction Type Addition Alone
Building Front Orientation. Front Facing 90 deg (E)
Number of Dwelling Units... 0.1
Number of Stories l
Floor Construction Type,... Raised Floor
Glazing Percentage 36.5 % of floor area
Average Glazing U-value.... O.Jl Btu/hr-sf-F
Average Glazing SHGC 0.47
Average Ceiling Height 9.3 ft
BUILDING SHELI INSULATION
Component
Type
Wall
Roof
FloorExt
Frame
Type
Wood
Wood
Wood
Cavity
R- value
R-13
R-30
R-19
Sheathing
R- value
R-0
R-0
R-0
Total
R-value
R-13
R-30
R-19
Assembly
U-value
0.088
0.035
0.048
Location/Comments
Attic
To Outside
FENESTRATION
Area
Orientation
Window
Window
Window
Window
Window
Window
Window
Window
Window
Window
Skylight
Back
Right
Right
Right
Left
Left
Left
Front
Left
Left
Front
(W)
(N)
(N)
(N)
(S)
(S)
(S)
(SE)
(S)
(SW)
(E)
(Sf)
35
12
16
12
16
7
5
6
10
6
4
.0
.3
.0
.3
.0
.0
.7
.0
.0
.0
.0
U-
Value
0
0
0
0
0
0
0
0
0
0
0
.300
.300
.300
.300
.300
.300
.300
.300
.300
.300
.750
SHGC
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
0.
470
470
470
470
470
470
470
470
470
470
400
Interior
Shading
Standard
Standard
Standard
Standard
Standard
Standard
Standard
Standard
Standard
Standard
None
Exterior
Shading
Standard
Standard
Standard
Standard
Standard
Standard
Standard
Standard
Standard
Standard
None
Over-
hang/
Fins
Q
> LLi«_J KUl if)
U> <?
iS
-
m Oo o