HomeMy WebLinkAbout2815 ELMWOOD ST; ; CB020999; Permit10-22-2002
Job Address:
Permit Type:
Parcel No:
Valuation:
Occupancy Group:
# Dwelling Units:
Bedrooms:
Project Title:
City of Carlsbad
1635 Faraday Av Carlsbad, CA 92008
Residential Permit Permit No: CB020999
Building Inspection Request Line (760) 602-2725
2815 ELMWOOD ST CBAD
RESDNTL Sub Type: RAD
1562304500 Lot#: 0
$46,350.00 Construction Type: NEW
Reference #:
0 Structure Type:
0 Bathrooms: 0
GONZALES RES/450 SF-FOYER, HAL
LIVING ROOM & BEDROOM- ENLARGING
Status:
Applied:
Entered By:
Plan Approved:
Issued:
Inspect Area:
Orig PC#:
Plan Check#:
ABANDOND
04/02/2002
CB
Applicant:
GONSALEZ THOMAS L&COURSON KELLY
2815 ELMWOOD ST
CARLSBAD CA 92008
729-7758
Owner:
GONSALEZ THOMAS L&COURSON KELLY
2815 ELMWOOD ST
CARLSBAD CA 92008
Total Fees:$561.52 Total Payments To Date:$219.38 Balance Due:$342.14
Building Permit
Add'l Building Permit Fee
Plan Check
Add'l Plan Check Fee
Plan Check Discount
Strong Motion Fee
Park in Lieu Fee
Park Fee
LFM Fee
Bridge Fee
Other Bridge Fee
BTD #2 Fee
BTD #3 Fee
Renewal Fee
Add'l Renewal Fee
Other Building Fee
Pot. Water Con. Fee
Meter Size
Add1) Pot. Water Con. Fee
Reel. Water Con. Fee
$337.51 Meter Size
$0.00 Add'l Reel. Water Con. Fee
$219.38 Meter Fee
$0.00 SDCWA Fee
$0.00 CFD Payoff Fee
$4.63 PFF
$0.00 PFF (CFD Fund)
$0.00 License Tax
$0.00 License Tax (CFD Fund)
$0.00 Traffic Impact Fee
$0.00 Traffic Impact (CFD Fund)
$0.00 Sidewalk Fee
$0.00 PLUMBING TOTAL
$0.00 ELECTRICAL TOTAL
$0.00 MECHANICAL TOTAL
$0.00 Housing Impact Fee
$0.00 Housing InLieu Fee
Master Drainage Fee
$0.00 Sewer Fee
$0.00 Additional Fees
TOTAL PERMIT FEES
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$561.52
Inspector:
FINAL APPROVAL
Date:Clearance:
NOTICE: Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively
referred to as "fees/exactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must
follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for
processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack,
review, set aside, void, or annul their imposition.
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity
changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any
fees/exactions of whicrLVQu have previously been given a NOTICE similar to this, or as lo which the statuteofllimitations has oreviouslv otherwise expired.
PERMIT APPLICATION
CITY OF CARLSBAD BUILDING DEPARTMENT
1635 Faraday Ave., Carlsbad, CA 92008
FOR OFFICE USE ONLY
PLAN CHECK
EST. VAL.
Plan Ck. Deposit
Validated By £
Date
SC.Business Name (at this address)
Legal Description Lot No.Subdivision Name/Number UnjtjNft. -., ....Phase No,,. - .-, Total # qtunits
Assessor's Parcel #
Name Address City State/Zip Telephone #
IfpiMlrt^^ ;.; :".:I-• :- '-'":••- x:-.-= , -:;\-:~.:i:":..»•-\': .:,;;.-.. :.::M:,-.;;:: '^^<: -^i;;;...,.^ = M,: .-.
(Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its
issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law
[Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code] or that he is exempt therefrom, and the basis for the alleged
exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars [$500]).
Name
State License #
Designer Name
State License #
Address
License Class
Address
City State/Zip
City Business License #
City State/Zip
Telephone #
Telephone
WORKERS'COMPENSATION
Workers' Compensation Declaration: I hereby affirm under penalty of perjury one of the following declarations:
Q I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance
of the work for which this permit is issued.
PI I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is
issued, My worker's compensation insurance carrier and policy number are:
Insurance Company Policy No. Expiration Date
(THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS [$100] OR LESS)
Q CERTIFICATE OF EXEMPTION: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as
to become subject to the Workers' Compensation Laws of California.
WARNING: Failure to secure workers' compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred
thousand dollars ($100,000), in addition to the cost of compensation, damages as provided for in Section 3706 of the Labor code, interest and attorney's fees.
SIGNATUREDATE
iBUItMR DEGLAfiATIOM
I hereby affirm that I am exempt from the Contractor's License Law for the following reason:
Q I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale
(Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does
such work himself or through his own employees, provided that such improvements are not intended or offered for sale, If, however, the building or improvement is
sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale).
\ST I. as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The
Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed
pursuant to the Contractor's License Law).
Q I am exempt under Section Business and Professions Code for this reason:
1. I personally plan to provide the major labor and materials for construction of the proposed property improvement. Q YES [~|NO
2. I (have / have not) signed an application for a building permit for the proposed work.
3. I have contracted with the following person (firm) to provide the proposed construction (include name / address / phone number / contractors license number):
4. I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone
number / contractors license number):
5. I will provide some of the work, but I rj^ve contracted (hired) the following persons to provide the work indicated (include name / address / phone number / type
of work):
PROPERTY OWNER SIGNATU,^ ^ DATE
COMPLETE THIS SECTION FOR A*/vVf5/D£*77i£ BUILDING PERMITS ONL1,
Is the applicant or future building ocdupary reguired to submit a business plan, acutely hazardous materials registration form or risk management and prevention
program under Sections 25505, 25533 or WS34 of the Presley-Tanner Hazardous SubstanceT^ccaunt Act? D YES Q NO
Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? O YES Q NO
Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? Q YES Q NO
IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE
REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT.
#I;;f?CQI^^ :"••''•:••••; ' :<* ' •' ' : ' ' - - ;
I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097(i) Civil Code).
LENDER'S NAME LENDER'S ADDRESS
City ordinances and State laws relating to building construction. I hereby authorize representatives of the CitV of Carlsbad to enter upon the above mentioned
property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES,
JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT.
OSHA: An OSHA permit is required for excavations over 5'0" deep and demolition or construction of structures over 3 stories in height.
EXPIRATION: Every permit issued by tha'building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work
authorized by such permit is not co/ma^lced within 1 SOdSQb from the date of such permit or/ff>e building or work authorized by sujbh perrr/ is suspended or abandoned
at any time after the work is comgjprfogd fjif7a£)eriod r/f 1^0 days^Sectjon 106.4.4 Uniforrr/gilding Coc
APPLICANT'S SIGNATURE
WHITE: File YELLOW: Applicant PINK: Fina
m
\
11
EsGil Corporation
In "Partnership ivitfr government for 'SuiCding Safety
DATE: 04/11/02
JURIS:
JURISDICTION: Carlsbad cTpLANREVlEWER
Q FILE
PLAN CHECK NO.: 02-999 SET: I
PROJECT ADDRESS: 2815 Elmwood Street
PROJECT NAME: Room Addition/Entry for Gonsalez Residence
The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes.
The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff.
The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
The check list transmitted herewith is for your information. The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck.
The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
The applicant's copy of the check list has been sent to:
Tom & Kelly Gonsalez
2815 Elmwood Street Carlsbad, Ca. 92008
Esgil Corporation staff did not advise the applicant that the plan check has been completed.
XI Esgil Corporation staff did advise the applicant that the plan check has been completed.
Person contacted: Tom-& Kelly Gonsalez Telephone #: (760) 729-7758
Date contacted: Hi/Jo 2. (by: ^- ) Fax #: (760) 730-9696
Mail '-""Telephone---' Fax"-"" In Person
REMARKS:
By: Ray Fuller Enclosures:
Esgil Corporation
D GA n MB D EJ PC 04/04/02 tmsmtWot
9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 •* (858)560-1468 + Fax (858) 560-1576
Carlsbad 02-999
04/11/02
PLAN REVIEW CORRECTION LIST
SINGLE FAMILY DWELLINGS AND DUPLEXES
PLAN CHECK NO.: 02-999 JURISDICTION: Carlsbad
PROJECT ADDRESS: 2815 Elmwood Street
FLOOR AREA:
Additions 450
Trellis 161
Entry 68
REMARKS:
DATE PLANS RECEIVED BY
JURISDICTION: 04/02/02
DATE INITIAL PLAN REVIEW
COMPLETED: 04/11/O2
STORIES: 1
HEIGHT: 13 ft per UBC
DATE PLANS RECEIVED BY
ESGIL CORPORATION: 04/04/02
PLAN REVIEWER: Ray Fuller
FOREWORD (PLEASE READ):
This plan review is limited to the technical requirements contained in the Uniform Building Code,
Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws
regulating energy conservation, noise attenuation and access for the disabled. This plan review
is based on regulations enforced by the'Building Department. You may have other corrections
based on laws and ordinance by the Planning Department, Engineering Department, Fire
Department or other departments. Clearance from those departments may be required prior to
the issuance of a building permit.
Present California law mandates that residential construction comply with the 1998 edition of
the California Building Code (Title 24), which adopts the following model codes: 1997 UBC,
1997 UPC, 1997 UMC and 1996 NEC (all effective 7/1/99).
The above regulations apply to residential construction, regardless of the code editions adopted
by ordinance.
The following items listed need clarification, modification or change. All items must be satisfied
before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3,
1997 Uniform Building Code, the approval of the plans does not permit the violation of any
state, county or city law.
To speed up the recheck process, please note on this list (or a copy) where each
correction item has been addressed, i.e., plan sheet number, specification section, etc.
Be sure to enclose the marked up list when you submit the revised plans.
Carlsbad 02-999
04/11/02
• PLANS
1. Please make all corrections on the original tracings, as requested in the correction
list.
Submit three sets of plans for commercial/industrial projects (two sets of plans for
residential projects). For expeditious processing, corrected sets can be submitted
in one of two ways:
1. Deliver all corrected sets pf plans and calculations/reports directly to the
City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92009,
(760) 602-2700. The City will route the plans to EsGil Corporation and the
Carlsbad Planning, Engineering and Fire Departments.
2. Bring one corrected set of plans and calculations/reports to EsGil
Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858)
560-1468. Deliver all remaining sets of plans and calculations/reports directly to
the City of Carlsbad Building Department for routing to their Planning, Engineering
and Fire Departments.
NOTE: Plans that are submitted directly to EsGil Corporation only will not
be reviewed by the City Planning, Engineering and Fire Departments until review
by EsGil Corporation is complete.
2. Specify on the Title Sheet of the plans the gross floor area of each element of
this project, including proposed trellis and entry. Section 106.3.3.
3. Electrical notes on sheet 1 should be updated to 96 coded i.e. notes E/ 3 thru
E/5 are referencing 93 code ( E/4 should state all kitchen counter outlets are now
to be GFCl protected).
4. Show or note that battery operated smoke detectors are required at all existing
bedrooms and hallways leading to'existing bedrooms .
5. Window D at entry on sheet 2 is to be tempered as within 24" of door. The door
size was not specified at this location and note or shown on the plans that the
maximum drop is 1 inch for the out swinging door shown. Section 1003.3.1.6
6. Show or note that existing garage has 5/8X protection where in common with
entry now. Show or note that existing door is a fire rated door and self closing.
7. The glass sliding door is not showing a landing ( minimum 36" in width) at
exterior of door. Allowed a 8" drop maximum but then a landing should be
provided equal to door width.
8. There is what appears to be a note in ink at den stating that window adjacent to
planter is to be relocated. Please specify size of new header if this is the case.
9. Show fireplace termination to be2 ft higher than any point within 10 ft on sheet 3.
Carlsbad 02-999
04/11/02
10. On sheet 5 could not locate detail S1/5 as referenced at entry .
11. Minimum length of shear panel is 2'8" for a maximum height of 10 ft to be
conventional. 2'6" is shown at entry area.
12. The 2'6" and 3'4" shear panels shown at entry on sheet 5 have side lights shown
on sheet E ?
13. The anchor bolt spacing noted on sheet 5 are referencing W bolts thru out.
14. Detail and reference the hold down bolts required i.e. retro fit hold downs to
have detail reference to appropriate locations showing all thread size, depth of
embedment and epoxy type. Detail 9/9 is stating hold down bolt per spec's but
could not locate where this was noted. Could specify SSTB 20's .
15. Could not read some of the length of shear panels on sheet 5 i.e. just before the
curved wall on sheet 5.
16. Specify how obtaining the radius for curved plates show for this area i.e. is the
sill plate cut from pressure treated %" or 1 1/8 " plywood or from dimensioned
lumber.
17. Appears that retro fit hold downs will be required at existing foundations. Note on
cover sheet special inspection required for epoxy anchors and complete
attached form.
18. Minimum slope for "flat roofs" is Vi" per foot or must design for pondage. 1/8" is
noted on roof framing plan.
19. Note on the plan that all roofing is to be Class A minimum per City policy.
20. The length's of the beams should be noted on the plans i.e. BM 1 so can verify
the back span and over turning effects of these beams.
21. Details on sheet 7 should reflect edge or boundary nailing of the roof diaphragm
to blocks . A-35 spacing should be noted.
22. Details shown on sheet 8 again should reflect edge nailing to roof rafters and
could not locate how these members are attached to the top plates i.e. A-35
spacing.
23. Section A/8 should reflect how wood is being protected i.e. 26 galv. metal. Note
that any existing foundation vents to be will be replaced.
Carlsbad 02-999
04/11/02
24. The removal of existing wall at living room wall and replacing with PLM beam
with various point loads is not conventional framing. The vertical loads to include
loads on foundation and the lateral loads need to be reviewed by licensed
architect and engineer and calculations provided to show that the proposed
vertical and lateral load path in conjunction with the existing loads are adequate
25. Should provide a GFCI outlet at the exterior if none are existing.
26. The window schedule shall clearly describe the required U-factor and solar heat
gain coefficient (SHGC) values and demonstrate compliance with the Title 24
energy calculations.
27. All sheets of the latest CF-1R form must be imprinted onto the plans (sheets 1 of
3, 2 of 3 and 3 of 3 must be included).
28. Note on the plans: "The manufactured windows shall have a label attached
certified by the National Fenestration Rating Council (NFRC) and showing
compliance with the energy calculations."
• To speed up the review process, note on this list (or a copy) where each correction
item has been addressed, i.e., plan sheet, note or detail number, calculation page,
etc.
• Please indicate here if any changes have been made to the plans that are not a
result of corrections from this list. If there are other changes, please briefly describe
them and where they are located in the plans.
• Have changes been made to the plans not resulting from this correction list?
Please indicate:
Yes Q No Q
The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake
Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468,
to perform the plan review for your project. If you have any questions regarding
these plan review items, please contact Ray Fuller at Esgil Corporation. Thank
you.
Carlsbad 02-999
04/11/O2
City of Carlsbad
Building Department
BUILDING DEPARTMENT
NOTICE OF REQUIREMENT FOR SPECIAL INSPECTION
Do Not Remove From Plans
Plan Check No. O2-999
Job Address or Legal Description 2815 Elm wood Street
Owner Address
You are hereby notified that in addition to the inspection of construction provided by the
Building Department, an approved Registered Special Inspector is required to provide continuous
inspection during the performance of the phases of construction indicated on the reverse side of
this sheet.
The Registered Special Inspector shall be approved by the City of Carlsbad Building
Department prior to the issuance of the building permit. Special Inspectors having a
current certification from the City of San Diego, Los Angeles, or ICBO are approved as
Special Inspectors for the type of construction'for which they are certified.
The inspections by a Special Inspector do not change the requirements for inspections by
personnel of the City of Carlsbad building department. The inspections by a Special
Inspector are in addition to the inspections normally required by the County Building
Code.
The Special Inspector is not authorized to inspect and approve any work other than that for which
he/she is specifically assigned to inspect. The Special Inspector is not authorized to accept
alternate materials, structural changes, or any requests for plan changes. The Special Inspector is
required to submit written reports to the City of Carlsbad building department of all work that
he/she inspected and approved. The final inspection approval will not be given until all Special
Inspection reports have been received and approved by the City of Carlsbad building department.
Please submit the names of the inspectors who will perform the special inspections on each of the
items indicated on the reverse side of this sheet.
(over)
Carlsbad O2-999
04/11/02
SPECIAL INSPECTION PROGRAM
ADDRESS OR LEGAL DESCRIPTION:
PLAN CHECK NUMBER: OWNER'S NAME:
I, as the owner, or agent of the owner (contractors may not employ the special inspector),
certify that I, or the architect/engineer of record, will be responsible for employing the special
inspector(s) as required by Uniform Building Code (UBC) Section 1701.1 for the construction
project located at the site listed above. UBC Section 106.3.5.
Signed
I, as the engineer/architect of record, certify that I have prepared the following special inspection
program as required by UBC Section 106.3.5 for the construction project located at the site listed above.
englnwr-«/ArchJt»cl'» S*al
& Signature Htri
Signed
1. List of work requiring special inspection:
Q Soils Compliance Prior to Foundation Inspection Q Field Welding
O Structural Concrete Over 2500 PSI Q High Strength Bolting
Q Prestressed Concrete £] Expansion/Epoxy Anchors
Q Structural Masonry \ Q Sprayed-On Fireproofing
Q Designer Specified Q Other
2. Name(s) of individual(s) or firm(s) responsible for the special inspections listed
above:
A.
B.
C.
3. Duties of the special inspectors for the work listed above:
A.
B.
C.
Special inspectors shall check in with the City and present their credentials for approval prior to beginning work on the job site.
Carlsbad 02-999
04/11/02
VALUATION AND PLAN CHECK FEE
JURISDICTION: Carlsbad PLAN CHECK NO.: 02-999
PREPARED BY: Ray Fuller DATE: 04/11/02
BUILDING ADDRESS: 2815 Elmwood Street
BUILDING OCCUPANCY: R3 TYPE OF CONSTRUCTION: VN
BUILDING
PORTION
Addition
Trellis
Entry
Air Conditioning
Fire Sprinklers
TOTAL VALUE
Jurisdiction Code
AREA
( Sq. Ft.)
450
161
68
CB
^
Valuation
Multiplier
Per City Est.
By Ordinance
Reg.
Mod.
VALUE ($)
46,350
46,350
$337.51
Type of Review:
Repetitive Fee
Repeats
Complete Review
D Other
i—, Hourly
Structural Only
Hour
Esgil Plan Review Fee
$219.38
$189.01
Comments:
Sheet 1 of 1
macvalue.doc
PLANNING/ENGINEERING APPROVALS
PERMIT NUMBER CB DATE
ADDRESS
RESIDENTIAL ADDITION MINOR
(< $10,000.00)
TENANT IMPROVEMENT
PLAZA CAMINO REAL
CARLSBAD COMPANY STORES
VILLAGE FAIRE
COMPLETE OFFICE BUILDING
OTHER
PLANNER DATE
ENGINEER DATE
Docs/Misfonms/Plannlng Engineering Approvals
PLANNING DEPARTMENT
BUILDING PLAN CHECK REVIEW CHECKLIST
Plan Check No. CB
Planner C~* fc
APN:
Address
Phone (760) 602-
Type of Project & Use:_
Zoning: I^( General Pian:_
CFD (in/out) #_Date of participation:
Net Project Density:.DU/AC
Facilities Management Zone: /
Remaining net dev acres:
Circle One {For non-residential development: Type of land used created by this
permit: )
D D
D
Legend: JAl Item Complete
Environmental Review Required:
DATE OF COMPLETION:
Item Incomplete - Needs your action
YES NO TYPE
Compliance with conditions of approval? If not, state conditions which require action.
Conditions of Approval:
Discretionary Action Required:
APPROVAL/RESO. NO.
PROJECT NO.
YES NO TYPE
DATE
OTHER RELATED CASES:
Compliance with conditions or approval? If not, state conditions which require action.
Conditions of Approval:
I I Coastal Zone Assessment/Compliance
Project site located in Coastal Zone? Y
CA Coastal Commission Authority?ES
If California Coastal Commissiprr Authority: Contact them at - 7575 Metropolitan Drive, Suite
103, San Diego CA 921004402; (619} 767-2370
Determine status (Coastal Permit Required or Exempt):
Coastal Permit Detemiination Form already completed? YES NO
If NO, complete/Coastal Permit Determination Form now.
Coastal Permit Determination Log #:
D D
Folioi Actions:
1) /Stamp Building Plans as "Exempt" or "Coastal Permit Required" (at minimum Floor Plans).
2} Complete Coastal Permit Determination Log as needed.
Inclusionary Housing Fee required:YES NO
(Effective date of Inclusionary Housing Ordinance - May 21, 1993.]
Data Entry Completed? YES NO
(A/P/Ds, Activity Maintenance, enter CB#, toolbar, Screens, Housing Fees, Construct Housing
Y/N, Enter Fee, UPDATE!)
H:\ADMIN\COUNTER\BldgPlnchkRevChklst Rev 9/01
n
nn
sran
n
n n
] n
n n n
Site Plan:
1. Provide a fully dimensional site plan drawn to scale. Show: North arrow, property lines,
easements, existing and proposed structures, streets, existing street improvements, right-
of-way width, dimensional setbacks and existing topographical lines (including all side and
rear yard slopes}.
2. Provide legal description of property and assessor's parcel number.
Policy 44 - Neighborhood Architectural Design Guidelines
1. Applicability: YES NO_V.
2. Project complies YES NO/
Zoning:
1. Setbacks:
Front:
Interior Side:
Street Side:
Rear:
Top of slope:
Required
Required
Required
Required
Required
^mf V
fzy^j)
CH CU CH 2. Accessory structure setbacks:
Front:
Interior Side:
Street Si
Shown
'"'hairrtn 7 J /^JIU VVl \ //____
Shown —•
Shown 2
Shown ,
fucture separation
3. Lot Coverage:
4. Height:
Required
Required
Required
Required
Required
V" 0
Shown
Shown
Shown
Shown
Shown
Shown
Shown
/.
(
n n n
5. Parking:Spaces Required Shown
(breakdown by uses for commercial and industrial projects required)
Residential Guest Spaces Required Shown
Additional Comments
OK TO ISSUE AND ENTERED APPROVAL INTO COMPUTER
H:\ADMlN\COUNTERNBldgPlnchkRevChklst Rev 9/01
1RTIFICATE OF COMPLIANCE: RESIDENTIAL Page 1 CF-1R
Date.,11/13/01 15:53:30*******
*v6.01********
•oject Title COURSON / GONSALEZ
-oject Address 2815 ELMWOOD STREET
CARLSBAD
icumentation Author... ROCKY
Salehi & Salehi Inc.
9636 Tierra Grande Street, Ste 206
San Diego, CA 92126
858-549-3680
.imate Zone 07
impliance Method MICROPAS6 v6.01 for 2001 Standards by Enercotnp, Inc.
Building Permit #
Plan Check / Date
Field Check/ Date
MICROPAS6 V6.01 File-01108 Wth-CTZ07S92 Program-FORM CF-1R
User#-MP0406 User-Salehi & Salehi Inc. Run-S.F.R.
GENERAL INFORMATION
Conditioned Floor Area 449 sf
Building Type Single Family Detached
Construction Type Addition Alone
Building Front Orientation. Front Facing 90 deg (E)
Number of Dwelling Units... 0.18
Number of Stories 1
Floor Construction Type.... Slab On Grade
Glazing Percentage 41.4 % of floor area
Average Glazing U-factor... 0.3 Btu/hr-sf-F
Average Glazing SHGC 0.47
Average Ceiling Height 9.8 ft
BUILDING SHELL INSULATION
xnponent
Type
ill
30f
LabEdge
Frame
Type
Wood
Wood
None
Cavity
R-value
R-13
R-30
R-0
Sheathing
R-value
R-0
R-0
R-0
Total
R-value
R-13
R-30
Assembly
U-factor
0.088
0.036
F2=0.760
Location/Comments
FENESTRATION
3rientation
Window
tfindow
Window
Window
Window
Window
Window
Front
Front
Front
Front
Back
Right
Left
(E)
(E)
(E)
(E)
(W)
(N)
(S)
Area
(sf)
40
26
40
10
15
40
15
.0
.0
.0
.0
.0
.0
.0
u-
Factor
0
0
0
0
0
0
0
.300
.300
.300
.300
.300
.300
.300
SHGC
0
0
0
0
0
0
0
.470
.470
.470
.470
.470
.470
.470
Interior
Shading
Standard
Standard
Standard
Standard
Standard
Standard
Standard
Exterior
Shading
Standard
Standard
Standard
Standard
Standard
Standard
Standard
Over-
hang/
Fins
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Type Exposed
THERMAL MASS
Area Thickness
(sf) (in) Location/Comments
SlabOnGrade
SlabOnGrade
No
Yes
219 3.5 Covered
138 3.5 ENTRY/HALL
— : LA -*- ^ 1 -i- ^
^?S op N p r^
^< r& N ^ ^r- ;- v>> M/ r" s-i i*<>l^ Sv ^7x ^
t fN ^ ^— L A ipi ^ 3\ti Vi o o .
r~--.
^ m1 ' h
^ ^^ 1-
0 Sa niS en
D
—i
oo
CO
>TJ
S>N a
THOMAS L&OO
^COOz^
c£2<og
^^gu) > <B
TI r^ Sn mgco
EmS
I5ELMWS/450 SFS. BEDRCOOD ST CBAC=-FOYER, H^DOM- ENLAFQi-
O
^r^.
r\j
CT
f
Ito