HomeMy WebLinkAbout2815 ELMWOOD ST; ; CB970819; PermitBUILDING
05/02/97 10:54
Page 1 of 1
job Address: 2815 ELMWOOD ST
Permit Type: RESIDENTAL ADD/ALT
Parcel No: 156-230-45-00
Valuation: 12,690
Occupancy Group: ^^r, «oc crDescription: RAD KITCHEN ENLARGE 135 SF
PERMIT
Suite:
Lot#:
Reference^:
Permit No: CB970819
Project No: A9701062
Development No:
4634 05/02/97 0001 01
Construction Type:
02
„„,NEW
Status: ISSUED
Applied: 04/08/97
05/02/97
JM
Apr/Issue
Entered By
Appl/Ownr
*
***
GONSALEZ, TOM
2815 ELMWOOD STREET
CARLSBAD, CA 92008
Fees Required ***
619 729-7758
es Collected & Credits
Fees :
Adjustments:
Total Fees:
Fee description
Building Permit
Plan Check
Strong Motion Fee
Other
* BUILDING TOTAL
259
it
* * *
.00
94. 00
165.00
Ext fee Data
144.00
94 . 00
1.00
20.00 ELECT
259.00
PPROVAL
CLEARANCE.
CITY OF CARLSBAD
2075 Las MUMS Dr., OuHbft, CA 92009 (619) 438-1161
PERMIT APPLICATION
CITY OF CARLSBAD BUILDING DEPARTMENT
2075 Las Palmas Dr., Carlsbad CA 92009
(760)438-1161
FOR OFFICE USE ONLY
PLAN CHECK
EST. VAL.
Plan Ck. Deposit
Validated By
Date
Address (include Bldg/Suite #)Business Name (at this address)
Legal Description ubdivision Name/Number Unit No.Phase No.Total # of units
Assessor's Parcel #Existing Use /Proposed Use
Description of Work SO. FT.#of Stories # of Bedrooms # of Bathrooms
Name Address City
for Owner' •
State/Zip Telephone #Fax #
City State/Zip Telephone #
City State/Zip Telephone #
(Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its
issuance, also requires the applicant for such permit to file a signed statement that tie is licensed pursuant to the provisions of the Contractor's License Law
(Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code] or that he is exempt therefrom, and the basis for the alleged
exemption. Any violation of Section 7031,5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars [$500]).
Name Address
State License # License Class
Designer Name Address
State License #
City State/Zip Telephone #
City Business License #
City State/Zip Telephone
Workers' Compensation Declaration: I hereby affirm under penalty of perjury one of the following declarations:
Q I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance
of the work for which this permit is issued.
Q I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is
issued. My worker's compensation insurance carrier and policy number are:
Insurance Company _ Policy No. _ Expiration Date _
(THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS [$100] OR LESS)
rj CERTIFICATE OF EXEMPTION: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as
to become subject to the Workers' Compensation Laws of California.
WARNING: Failure to secure workers' compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred
thousand dollars ($100,000), in addition to the cost of compensation, damages as provided for in Section 3706 of the Labor code, interest and attorney's fees.
SIGNATURE _ _ DATE _
I hereby affirm that I am exempt from the Contractor's License Law for the following reason:
n I. as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale
(Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does
such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is
sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale).
St I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The
Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractors} licensed
pursuant to the Contractor's License Law).
O I am exempt under Section _ Business and Professions Code for this reason:
( 1 . I personally plan to provide the major labor and materials for construction of the proposed property improvement. f~) YES C]NO
r 2. I (have / have not) signed an application for a building permit for the proposed work.
V 3. I have contracted with the following person (firm) to provide the proposed construction (include name / address / phone number / contractors license number):
T* 4. I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone
number / contractors license number): _
~y 5. I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone number / type
of work):
PROPERTY OWNER SIGNATURE
Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention
program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? fj YES Q NO
Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? Q YES
Is the facility to be constructed within 1 ,000 feet of the outer boundary of a school site? QJ YES Q NO
IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE
REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT.
NO
I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097(i) Civil Code).
LENDER'S NAME LENDER'S ADDRESS
I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all
City ordinances and State laws relating to building construction. I hereby authorize representatives of the City of Carlsbad to enter upon the above mentioned
property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES,
JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT.
OSHA: An OSHA permit is required for excavations over 5'0" deep and demolition or construction of structures over 3 stories in height.
EXPIRATION: Every permit issued by the Building Official under the provisions of this Code shall expire by limitation and become null and void if the building or
work authorized by such permit is not commenced within 365 days from the date of such permit or if the building or work authorized by such permit is suspended
or abandoned at any time after the? work is commenced for a period-qf 180 days (Section 106.4.4 Uniform Building Code).
APPLICANT'S SIGNATURE fyQjLJ. *tUA*4. *-^ J DATE if— *5 ~ M ~)
WHITE: File YELLOW: Applicant PINK: Finance
CITY OF CARLSBAD
INSPECTION REQUEST
PERMIT* CB970819 FOR 12/08/97
DESCRIPTION: RAD KITCHEN ENLARGE 135 SF
TYPE: RAD
JOB ADDRESS: 2815 ELMWOOD ST
APPLICANT: GONSALEZ, TOM
CONTRACTOR:
OWNER:
REMARKS: C/729-7758
SPECIAL INSTRUCT:
PHONE:
PHONE:
PHONE:
INSPECTOR AREA PD
PLANCK* CB970819
OCC GRP
CONSTR. TYPE NEW
STE: LOT:
619 729-7758
INSPECTO
TOTAL TIME:
CD LVL DESCRIPTION
19„ ST Final Structural
ACT COMMENTS
***** INSPECTION HISTORY *****
DATE DESCRIPTION
093097 Final Combo
070797 Drywall/Ext Lath/Gas Test
070297 Interior Lath/Drywall
070297 Gas/Test/Repairs
070197 Interior Lath/Drywall
062597 Insulation
062097 Frame/Steel/Bolting/Welding
062097 Rough/Topout
062097 Rough Electric
050697 Ftg/Foundation/Piers
ACT
CA
AP
CO
CO
NR
AP
AP
AP
AP
AP
INSP
PD
PD
DC
DC
DC
DC
DC
DC
DC
DC
COMMENTS
NOBODY HOME
NOBODY HOME
NO ONE AT UNIT 12:45
EsGil Corporation
$rofessionaC<p[an Review 'Engineers
DATE: 4/29/97 a ^APPLICANT
_
JURISDICTION: Carlsbad G PLAN REVIEWER
a FILE
PLAN CHECK NO.: 97-819 SET: II
PROJECT ADDRESS: 2815 Elmwood St.
PROJECT NAME: Residential Kitchen Enlargement
H The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes.
The plans transmitted herewith will substantially comply with the jurisdiction's XAAAIX*A** codes
when minor deficiencies identified below are resolved and checked by building department staff.
The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
The check list transmitted herewith is for your information. The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck.
The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
The applicant's copy of the check list has been sent to:
Esgil Corporation staff did not advise the applicant that the plan check has been completed.
Esgil Corporation staff did advise the applicant that the plan check has been completed.
Person contacted: Telephone #:
Date contacted: (by: ) Fax #:
Mail Telephone Fax In Person
REMARKS: City to field verify that the window area for the new and existing kitchen will
provide 1/10 of the floor area in light, 1/2 openable for ventilation.
By: Chuck Mendenhall Enclosures:
Esgil Corporation
D GA D CM D EJ D PC 4/22/97 tmsmtl.dot
9320 Chesapeake Drive, Suite 208 * San Diego, California 92123 •* (619)560-1468 + Fax (619) 560-1576
EsGll Corporation
Professional $'tan {Review Engineers
DATE: 4/17/97 O£EEUQANT
EfjURlS/)
JURISDICTION: Carlsbad CTPCArTREVIEWER
Q FILE
PLAN CHECK NO.: 97-819 SET: I
PROJECT ADDRESS: 2815 Elmwood St
PROJECT NAME: Residential Kitchen Enlargement
The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's *********** codes.
The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
The remarks below are transmitted herewith for your information. The plans are being held at
Esgil Corporation until corrected plans are submitted for recheck. Submit 3 sets of plans to the
city or submit 2 sets of plans to the city and one set directly to EsGil Corp. for recheck
The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
The applicant's copy of the check list has been sent to:
Thomas Gonzales
2815 Elmwood St., Carlsbad, CA 92008
Esgil Corporation staff did not advise the applicant (except by mail) that the plan check has been
completed.
Esgil Corporation staff did advise the applicant that the plan check has been completed.
REMARKS: 1. Note on the plans that smoke detectors will be provided inside all existing bed rms
and hall serving the bed rms, UBC 310.9.1.2. 2. Show or note on the plans that a min. 18"X24"
crawl space will be provided. 3. The anchor bolts must be a min of 10" long to achieve a min. of
7" embedment. 4. Foundation stem wall must be a min. of 6" wide. 5. Show on the plan that
exterior grade is a min. of 6" below the bottom plate. 6. Provide a floor plan of the existing
dining rm, and kitchen to show how the required natural light and ventilation is provided. Specify
the size and type of windows and doors in the kitchen extension and the existing kitchen/dining
rm. 7. Provide energy documentation to show compliance with the state energy standards.
Complete the attached energy form CF-1R, sign and attach it to the plans. 8. Show on the plans
the roof, wall and floor insulation. Also, note that the new window must be dual glazed.
By: Chuck Mendenhall Enclosures: CF-ifc < fcuEeoy S-nai
Esgil Corporation 4/10/97
9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (619)560-1468 * Fax (619) 560-1576
VALUATION AND PLAN CHECK FEE
JURISDICTION: Carlsbad
PREPARED BY: CM
BUILDING ADDRESS: 2815 Elmwood St
BUILDING OCCUPANCY: R3
PLAN CHECK NO.: 97-819
DATE: 4/18/97
TYPE OF CONSTRUCTION: VN
BUILDING PORTION I BUILDING AREA
I (ft-2)
addition
Air Conditioning
Fire Sprinklers
TOTAL VALUE
133
VALUATION I VALUE
MULTIPLIER I ($)
94 12502
12502
• 1991 UBC Building Permit Fee D Bldg. Permit Fee by ordinance: $ 144.00
• 1991 UBC Plan Check Fee D Plan Check Fee by ordinance: $ 93.60
Type of Review: • Complete Review Q Structural Only C3 Hourly
D Repetitive Fee Applicable n Other:
Esgil Plan Review Fee: $ 74.88
Comments:
Sheet 1 of 1
macvalue.doc 5196
City of Carlsbad
Engineering Department
DATE:4—1 S-
BUILDING PLANCHECK CHECKLIST
PLANCHECK NO.:
BUILDING ADDRESS:
PROJECT DESCRIPTION:
ASSESSOR'S PARCEL NUMBER:
ENGINEERING DEPARTMENT
APPROVAL
The item you have submitted for review has been
approved. The approval is based on plans,
information and/or specifications provided in your
submittal; therefore any changes to these items after
this date, including field modifications, must be
reviewed by this office to insure continued
conformance with applicable codes. Please review
carefully all comments attached, as failure to comply
with instructions in this report can result in
suspension of permit to build.
A Right-of-Way permit is required prior to
construction of the following improvements:
DENIAL
Please seAthe attached report of deficiencies
marked wijMx Make necessary corrections to plans
or specifications for compliance with applicable
codes and standards. Submit corrected plans and/or
specifications to this office for review.
By:
By:
Date:
Date:
FOR OFFICIAL USE ONLY
ENGINEERING AUTHORIZATION TO ISSUE BUILDING PERMIT:
Date:
ATTACHMENTS
Dedication Application
Dedication Checklist
Improvement Application
Improvement Checklist
Future Improvement Agreement
Grading Permit Application
Grading Submittal Checklist
Right-of-Way Permit Application
Right-of-Way Permit Submittal Checklist
and Information Sheet
Sewer Fee Information Sheet
\<LMMlma»\5VS\LIBRAR>TENQVWORDCQCS«a<KLS-nBiilldinn Pton^pck Ckbl BPOQ01 Form MM doc
ENGINEERING DEPT. CONTACT PERSON
Name: Michele Masterson
City of Carlsbad
Address: 2075 Las Palmas Dr.. Carlsbad, CA 92009
Phone: (619)438-1161, ext. 4315
A-4
Rev. 1 Las Palmas Dr. • Carlsbad, CA 92OO9-1576 • (619) 438-1161 • FAX (619) 438-O894
BUILDING PLANCHECK CHECKLIST
SITE PLAN
1. Provide a fully dimensioned site plan drawn to scale. Show:
A. North Arrow D. Property Lines
B. Existing & Proposed Structures E. Easements
C. Existing Street Improvements F. Right-of-Way Width & Adjacent Streets
G. Driveway widths
jtterns
1. Building padsurface drainage must maintain a minimum slope of one
percent towards an adjoining street or an approved drainage course.
2. ADD THE FOLLOWING NOTE: "Finish grade will provide a minimum positive
drainage of 2% to swale 5' away from building."
B. Existing & Proposed Slopes and Topography
Q 3. Include oh title sheet:
A. Site address
B. Assessor's Parcel Number
C. Legal Description
For commercial/industrial buildings and tenant improvement projects, include:
total building square footage with the square footage for each different use,
existing sewer permits showing square footage of different uses (manufacturing,
warehouse, office, etc.) previously approved.
EXISTING PERMIT NUMBER DESCRIPTION
DISCRETIONARY APPROVAL COMPLIANCE
Q D 5. Project does not comply with the following Engineering Conditions of approval for
Project No.
Q Q 6. All conditions are in compliance. Date:
\yj!p»l™sUys\UBRARr£NQ\WORIMXx;SlCHKLST«uidlog PtancTieck Cklst BPOQ01 Form MM.docRev.
BUILDING PLANCHECK CHECKLIST
DEDICATION REQUIREMENTS
7. Dedication for all street Rights-of-Way adjacent to the building site and any storm
drain or utility easements on the building site is required for all new buildings and
for remodels with a value at or exceeding $ , pursuant to Carlsbad
Municipal Code Section 18.40.030.
Dedication required as follows:
Dedication required. Please have a registered Civil Engineer or Land Surveyor
prepare the appropriate legal description together with an 8 14" x 11" plat map
and submit with a title report. All easement documents must be approved and
signed by owner(s) prior to issuance of Building Permit. Attached please find an
application form and submittal checklist for the dedication process. Submit the
completed application form with the required checklist items and fees to the
Engineering Department in person. Applications will not be accept by mail or fax.
Dedication completed by: Date:
IMPROVEMENT REQUIREMENTS
rj Q Q 8a. All needed public improvements upon and adjacent to the building site must be
constructed at time of building construction whenever the value of the
construction exceeds $ , pursuant to Carlsbad Municipal Code
Section 18.40.040.
Public improvements required as follows:
Attached please find an application form and submittal checklist for the public
improvement requirements. A registered Civil Engineer must prepare the
appropriate improvement plans and submit them together with the requirements
on the attached checklist to the Engineering Department through a separate plan
check process. The completed application form and the requirements on the
checklist must be submitted in person. Applications by mail or fax are not
accepted. Improvement plans must be approved, appropriate securities posted
and fees paid prior to issuance of building permit.
Improvement Plans signed by; Date:
Q Q Q 8b. Construction of the public improvements may be deferred pursuant to Carlsbad
Municipal Code Section 18.40. Please submit a recent property title report or
current grant deed on the property and processing fee of $ so
we may prepare the necessary Future Improvement Agreement. This agreement
must be signed, notarized and approved by the City prior to issuance of a
Building permit.
Future public improvements required as follows:
\\L«Spalmia\ays4.1BRARY\eNO\WORD\DOC&CHKLSTeu»itti9 Punched! CkM BP0001 Form MM.dOc
Rev. 12/28/98
BUILDING PLANCHECK CHECKLIST
A st/ ond/
G G
G Q
8c. Enclosed please find your Future Improvement Agreement,
agreement signed and notarized to the Engineering Department.
Future Improvement Agreement completed by:
Date:
Please return
8d. No Public Improvements required. SPECIAL NOTE: Damaged or defective
improvements found adjacent to building site must be repaired to the satisfaction
of the City Inspector prior to occupancy.
Q Q Q
Q Q Q
GRADING PERMIT REQUIREMENTS
The conditions that invoke the need for a grading permit are found in Section
1 1 .06.030 of the Municipal Code.
9a. Inadequate information available on Site Plan to make a determination on grading
requirements. Include accurate grading quantities (cut, fill import, export).
9b. Grading Permit required. A separate grading plan prepared by a registered Civil
Engineer must be submitted together with the completed application form
attached. NOTE: The Grading Permit must be issued and rough grading
approval obtained prior to issuance of a Building Permit.
Grading Inspector sign off by:Date:
G G
G Q
G
9c. Graded Pad Certification required. (Note: Pad certification may be required even
if a grading permit is not required.)
9d. No Grading Permit required.
MISCELLANEOUS PERMITS
10. A RIGHT-OF-WAY PERMIT is required to do work in City Right-of-Way and/or
private work adjacent to the public Right-of-Way. Types of work include, but are
not limited to: street improvements, tree trimming, driveway construction, tieing
into public storm drain, sewer and water utilities.
Right-of-Way permit required for:
V\Laipalmas\iyi\LlBRARY>£Na\VVDRO>DOCS\CHKLS'neuWlng Plincheck CMsl BP0001 Form MM.Ooc
Rev. 12K6HB
BUILDING PLANCHECK CHECKLIST
•i st/ ond/ V^
Q Q Q 11. A SEWER PERMIT is required concurrent with the building permit issuance. The
fee is noted in the fees section on the following page.
Q Q Q 12. INDUSTRIAL WASTE PERMIT is required. Applicant must complete Industrial
Waste Permit Application Form and submit for City approval prior to issuance of a
Permit.
Industrial Waste permit accepted by:
Date:
Q Q Q 13. NPDES PERMIT
Complies with the City's requirements of the National Pollutant Discharge
Elimination System (NPDES) permit. The applicant shall provide best
management practices to reduce surface pollutants to an acceptable level prior to
discharge to sensitive areas. Plans for such improvements shall be approved by
the City Engineer prior to issuance of grading or building permit, whichever
occurs first.
Q Q 14. Q Required fees are attached
QH^o fees required
Q Q Q 15. Additional Comments:
\\Uspalmu\sy«\LIBRARY>ENO\WORD\OOCS>CHKLST\Bulldk« Ptoncheck Ckfet BP0001 Form MM,doc
Rev. 12/26/96
o o
n
n n
PLANNING DEPARTMENT
BUILDING PLAN CHECK REVIEW CHECKLIST
Plan Check No. CB
Planner Gre9 Fisner
APN: Vl'
Address
Phone {61 9) 438-1 1 61 , extension 4328
Type of Project and Use:
Zone: V-^( Facilities Management Zone:
CFD (in/cffjtT>
CircleKOrre (|f property in, complete SPECIAL TAX CALCULATION WORKSHEET provided by Building
Department.)
Legend
X] Item Complete
Item Incomplete - Needs your action
Environmental Review Required: YES
DATE OF COMPLETION:
TYPE
Compliance with conditions of approval? If not, state conditions which require action.
Conditions of Approval
Discretionary Action Required:
APPROVAL/RESO. NO.
PROJECT NO.
YES NO
DATE
TYPE
OTHER RELATED CASES:
Compliance with conditions or approval? If not, state conditions which require action.
Conditions of Approval
Coastal Zone Assessment/Compliance
Project site located in Coastal Zone? YES NO
NOCarlsbad Permit Authority or CA Coastal Commission Authority? YES
If California Coastal Commission Authority: Contact thenr at - 3111 Camino Del Rio North, Suite
200, San Diego CA 92108-1725; (619) 521-8-36
Determine status (Coastal Permit Required of Exempt):
Coastal Permit Determination Form already completed? YES NO
If NO, complete Coastal Permit Determination/orm now.
Coastal Permit Determination Log #:
Follow-Up Actions:
1) Stamp Building Plans as "|&empt" or "Coastal Permit Required" (at minimum
Floor Plans).
2) Complete Coastal Perm/t Determination Log as needed.
CD D Inclusionary Housing Fee required: YES
S.D D
an
a a
ana
NO
(Effective date of Inclusionary Housing Ordinance - May 21, 1993.)
Date Entry Completed? YES
Site Plan:
1. Provide a fully dimensional site plan drawn to scale. Show: North arrow,
property lines, easements, existing and proposed structures, streets, existing
street improvements, right-of-way width, dimensional setbacks and existing
topographical lines.
CD CD 2- Provide legal description of property and assessor's parcel number.
D D
Zoning:
1. Setbacks:
Front:
Int. Side:
Street Side:
Rear:
2. Accessory Structure
Front:
Int. Side:
Street Side:
Rear:
^
3. Lot Coverage:
Required ' O
Required /O
Required
Required "*T^?^
Setbacks:
Required
Required ^ — -""
Required^^
Becjtilred
^
- _, t-^-tdtfnRequired — ~ ' >u
Shown ^
Shown //
Shown —
Shown ^7 2o*
^Sbewrr— -
Shown
Shown
Shown
Shown ' fba
D 4. Height:Required L~ 7^Shown
— -J5. Parking: Spaces Required C
Guest Spaces Required ~
^ Shown ^ —
Shown
Additional Comments
OK TO ISSUE AND ENTERED APPROVAL INTO COMPUTER DATE
JM Engineering Group
Structural Consultants
(619)746-1913
STRUCTURAL CALCULATIONS
PROJECT:ROOF BEAM DESIGN
ADDITION
2815 ELM WOOD STREET
CARLSBAD, CA
CLIENT:THOMAS GONSALEZ
KELLY COURSON
JOB NO:97009
DATE:APRIL 2, 1997
PREPARED BY: JESSE D. MOORE
DESIGN CRITERIA
(REFERENCE: 1994 UNIFORM BUILDING CODE)
ROOF DEAD LOAD:
COMPOSITION ROOFING 3.5 PSF
REROOF 2.0 PSF
1/2" PLYWOOD SHTHG 1.5 PSF
ROOF FRAMING 2.5 PSF
INSULATION 1.0 PSF
1/2" DRYWALL CEILING 2.5 PSF
MISCELLANEOUS 1.0 PSF
TOTAL ROOF DEAD LOAD 13 PSF
ROOF LIVE LOAD = 16 PSF
TIMBER JOIST & RAFTER DESIGN
rb1
nccTftu ftATAucaiuN UA i A —
Timber Section
Depth
....Width
Le: Unsupp
Fb- Allow
Fv- Allow
Elastic Mod.
Load Duration Factor
Stress Ratio
rrUTrir TAUl*cn i CK ornn
Span Length
Uniform Dl
LL
Mmax a Cntr
X-Dist
- BClPTTfMJCKCnl.1 tUN 9
Left: Dead Load
Live Load
Right: Dead Load
Live Load
Fb.. Allow
Fb.. Actual
Fv.. Allow
Fv.. Actual
rtPTl Pmnucucri-cu i i UNO
Center... Dead Load
X-Dist
DL Ratio
Live Load
X-Dist
LL Ratio
Total Defl
X-Dist
Ratio
in
in
ft
psi
psi
ksi
-»
ft
ptf
plf
k-in
ft
#
#
#
#
psi
psi
psi
psi
in
ft
in
ft
in
ft
addition
97009
rb1
11 •
4X8
7.25
3.50
0.00
1050.00
95.00
1600.00
1.25
0.90
-n^-
11.50
90.00
92.00
36.10
5.75
517.50
529.00
517.50
529.00
1312.5
1177.5
118.75
55.26
-0.199
5.75
693
-0.204
5.75
678
-0.403
5.75
343
4-21-97
Attn: Chuck Mendenhall
Re: plan check no 97-819
Please find the corrections you required for the Gonzales-Courson kitchen enlargement on
the following pages:
remark no.
1
2
3
4
5
6
7
page no.
3
3
5
5
7
3
9+10
5
Thanks,
ArtSault (760)729-1859
p.s.- sorry about the hand drawn plans. The Gonzales' are close personal friends and I am
trying to save them some money.
REMARKS
D... ^^'
4,
Floor
/
\o-
* 5
tu'ftk
SO ".0 .O
M
•V
o *
o "•' c{-• <. <r-
o
COo
ro
fO
Ou
1
w
o
0
j*.
^ !<•Q ^
\A\
'Ai ,PW 0 'C.ro i
^ 0.
-^ ^
^icv\ ' '-XN* <T -i
•**^"^N^ -.^* „
CO ^^J ^
0 ^V 1A
t*
o
^ -MI *.*
r\ ^l \_*^ vylVj^
1 Uto^ vr ^
~-\c:• o
3 c
c u
'M
S^0 £r£
f
•talN
(a? is . , . r t\N
^\\\\\\\\\\\^^
vlSi)
xl
Uj
0^
_1
^ f-
a
o
The land referred to in this Report is situated in the State of California, County of
San Diego, and is descriised as-follows:
THE SOUTHERLY 100.00 FEET OF THAT PORTION OF THE NORTHWEST QUARTER OF SECTION 6,
TOWNSHIP 12 SOUTH, RANGE 4 WEST, SAN BERNARDINO BASE AND MERIDIAN, IN THE CITY OF
CARLSBAD, COUNTY OF SAN DIEGO, -STATE OF CALIFORNIA, ACCORDING TO UNITED STATES
GOVERNMENT SURVEY APPROVED, OCTOBER 25, 1875, BOUNDED BY A LINE DESCRIBED AS FOLLOWS,
TO WIT:
CCM^ENCING AT THE NORTHWEST CORNER OF SAID SECTION 6; THENCE AI£NG THE NORTHERLY
BOUNDARY LINE OF SAID SECTION 6, SOUTH 89°59100" EAST, A DISTANCE OF 2430.77 FEET TO
THE POINT OF BEGINNING; THENCE CCNTINUIN3 AI£NG SAID SECTION LINE, SOUTH 89°59'00"
EAST, A DISTANCE OF 147.02 FEET TO A POINT, SAID POINT BEIKC ALSO THE NORTHWEST CORNER
OF TRACT 121 OF CARLSBAD IANDS, AS SHOWN CN MAP 1661, CN FILE IN THE OFFICE OF THE
COUNTY RECORDER OF SAN DIEGO COUNTY; THENCE SOUTH 00°55'00" EAST AI£N3 THE WESTERLY
BOUNDARY LINE OF TRACT 121, CARLSBAD IANDS AND ALSO ALCNG THE WESTERLY LINE OF TRACT
119 OF CARLSBAD IANDS, AS SHOWN CN MAP NO. 1661 CN FILE IN THE OFFICE OF THE COUNTY
RECORDER OF SAN DIEQO COJNTY, A DISTANCE OF 332.73 FEET TO A POINT; THENCE SOUTH
89051'35" WEST, A DISTANCE OF 147.01 FEET TO A POINT; THENCE NORTH 00°55'00" WEST, A
DISTANCE OF 333.46 FEET TO THE POINT OF BEGINNING.
ENERGY REQUIREMENTS FOR RESIDENTIAL ROOM ADDITIONS - CLIMATE ZONE 7
Floor Area of Room Addition
COMPONENT
INSULATION
Ceiling
Wall
Floor
<100 ft:
R-19
R-13
R-13
GLA2ING (FENESTRATION)
U-Value1 0.75
% of added floor area ^50 sq. ft
SHADING
THERMAL MASS
n/a
n/a
Note 45SPACE HEATING
(no electric allowed)
If Gas, efficiency=
If Heat Pump:
Split System, efficiency=
Single Package System, eff.=
SPACE COOLING Note5
If Split System, eff.=
If Single Package, eff.=
WATER HEATING Note
100-499 ft:
R-30
R-13
R-19
0.75
20% + Removed2
.663
Req.4
78%AFUE5
6.8HSPF5
6.6HSPF5
10.0SEER3
9.7SEER5
Note6
500-999 ft2
R-30
R-13
R-19
0.75
20% + Removed2
.663
Req.4
78%AFUE5
6.8HSPF5
6.6HSPF5
10.0SEER5
9.7SEER5
Note6
>1000 ft:
R-30
R-13
R-19
0.75
20%
,663
Req.4
78%AFUES
6.8HSPF5
6.6HSPF3
10.0SEER3
9.7SEER5
Note6
1. Please note that some metal-frame windows may not satisfy the U-value requirement of
0.75. For additions and alterations only, dual glazed "greenhouse" windows and
skylights may be assumed to meet this requirement.
2. 20% of added floor area plus the area of any glazing removed because of the addition.
3. A coefficient of 0.66 will be assumed to be provided when dual glazing is used.
4. If the addition will be on top of existing construction, and:
(a) If the addition has conditioned area below all portions, then no thermal mass is
required.
(b) If the addition will be over non-conditioned area (partially or wholly) in a building
mostly of raised-floor construction (after the addition), then thermal mass is required
in the addition (equal to 5% of the area of the addition that is over non-conditioned
space). This may be provided by showing a 2" concrete slab at hearths, countertops,
etc. '
(c)If the addition will be over non-conditioned area in a building mostly of slab-on-
grade construction (after the addition) , then no thermal mass is required.
If the addition will be at the ground floor, and:
(a) If the addition will be in a building mostly of raised-floor construction (after the
addition) , then thermal mass is required in the addition (equal to 5% of the added
conditioned footprint area) . This may be provided by showing a 2" concrete slab at
hearths, countertops, etc.
(b) If the addition will be in a building mostly of slab-on-grade construction (after
the addition) , then thermal mass is required in the addition (equal to 20% of the added
conditioned slab-on-grade floor area). This may be provided by covering a portion of
the slab-on-grade with tile, wood, etc.
5. If the existing system will be utilized (if no additional systems are needed to provide
UBC heating requirements), there are no special requirents, other than mandatory
insulation for any extended ducts, etc.
6. If the total number of water heaters increases in the residence, then calculations must
be submitted to show that the entire existing-plus-addition system meets the water
heating energy budget.
ui or -1 n
S -
:7roj»cl Title Dal*
HVAC SYSTEMS
Note: Input hydronic or combined hydronic data under Water Heating Systems, except Design Heating Load,
Distribution
Heating Equipment Minimum Type and Duct or
Type (furnace, heat Efficiency Location Piping Thermostat
pump, etc.) (AFUE/HSPF) (duc^/anic. sic.) R-Value Type
Heat Pump
Configuration
(solft or package)
•V.
Cooling Equipment Minimum
Type {air conditioner, Efficiency
heat pump, evap. cooling) (SEER)
Duct
Location
(atfc.
Duct Thermostat
Type
WATER HEATING SYSTEMS
Configuration
(solit orpackaae)
Water Healer
Type
Distribution
Tvpe
Energy External
Rated Tank Factor or Tank
Number Input (kW Capacity Recovery Standby1 Insulation
in System or Btu/hr) (gallons) Efficiency Loss f%) R-Value
o 1. For small gas storage (rated inputs 75.000 6tu/hr),j^*ctrtc resistance and heat pump water heaters, list Energy Facsr.
For large gas storage water htatera (rated input 2 /=,000 Btu/hr), list Rated Input. Recovery Efficiency and Star.eby Less.
For Instantaneous gas water heaters, list Raied Input and Recovery Efficiency.
SPECIAL FEATURES/REMARKS (Add extra sheets if necessary)
COMPLIANCE STATEMENT
This certificate of compliance lists the building features arid performance specifications needed !o comply witfi Title 24, Farts 1 and 6. of
the California Code of Regulations, and the adminislrativs regulations to implement them. This certificate has been signed by the
individual with overall design responsibility. When this certificate of compliance is submitted for a single building plan to be built in rr.LiJpi
orientations, any shading feature that is varied is indicted in the Special Features/Remarks section.
Or Owner (per Business & Professions Code)
Title/Firm:
Address:
Telephone:
Lie. 9:
(signature)
Enforcement Agency
Name:
Title:
Agency: JJ
Telephone:
(date)
Documentation Author
Name:
Ti tie/Firm:
Address:
Telephone:
(signature)(date)
(signature/stamp)
Compliance Forms
(date)
January 1, 1995
Certificate of Compliance: nesiaenuai i 01
Project Addreu
Documentation Author
Compliance Method (Package, Point System or Computer)
Telephone
#7Climate Zone
Dtle
Building Permit*
Plan Check/Date
Field Check/Date
Enforcement Agency Usa Only
GENERAL INFORMATION
Total Conditioned Floor Area:
Building Type:
(check one or rr.ore)
Front Orientation;
y? Single Familyf Mufti-Family
Addition
Existing-
North / East / Sculh / West / All Orientations
(Input orientation in decrees and cirde one.)
Number of Dwelling Unfts:
Floor Constnjction Type:SlabC? Raised Flog (circle one or both)
BUILDING SHELL INSULATION
Construction
Component Insulation Assembly Location/Comments
Type R-Value U-Value fanic. to garage, typical, etc.)
Wai! >€
Wall
Roof ~"j£
Roof
Floor
Floor..-. £
Slab Edge ....
TT—~i
FENESTRATION
Fenestration Area
Orientation (sf)
Shading Devices
Fenestration
U-Value
Interior .
(roller blind, etc.)
Exterior
[shadescreen, etc.)
ytiang Framing Type
frr.e'ial/woodvinyl)
Front (U)
Front (\fj)
Left ( )
Left ( )
Rear ( )
Rear ( )
Right ( )
Right ( )
Skylight
Skylight
THERMAL MASS
Type/Covering
(slab/exposed, tile, eic.)
Area Thickness
(sf) (inches) Location/Description (kitchen, bath, etc.)
Forms January 1. 1995