Loading...
HomeMy WebLinkAbout2815 ELMWOOD ST; ; CB992396; Permit08-21-2006 Job Address: Permit Type: Parcel No: Valuation: Occupancy Group: # Dwelling Units: Bedrooms: Project Title: City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Residential Permit Permit No:CB992396 Building Inspection Request Line (760) 602-2725 2815 ELMWOOD ST CBAD RESDNTL 1562304500 $171,892.00 27 0 0 GONSALEZ/COURSON ADDITION 1 ST & 2ND STORY ADDITION 1754SF Sub Type: Lot#: Construction Type: Reference #: Structure Type: Bathrooms: RAD 0 VN Applicant: PLATO CARPADAKIS 3169 CHELSEA PARK CR SPRING VALLEY CA 91978 619-670-0895 Status: Applied: Entered By: Plan Approved: Issued: Inspect Area: Orig PC#: Plan Checktt: ABANDOND 06/29/1999 DT 12/06/1999 Owner: GONSALEZ THOMAS L&COURSON KELLY 2815ELMWOODST CARLSBAD CA 92008 Building Permit Add'l Building Permit Fee Plan Check Add') Plan Check Fee Plan Check Discount Strong Motion Fee Park in Lieu Fee Park Fee LFM Fee Bridge Fee Other Bridge Fee BTD #2 Fee BTD #3 Fee Renewal Fee Add'l Renewal Fee Other Building Fee HMP Fee Pot. Water Con. Fee Meter Size Add'l Pot. Water Con. Fee Reel. Water Con. Fee $873.08 Meter Size ($873.08) Add'l Reel. Water Con. Fee $567.50 Meter Fee $0.00 SDCWA Fee $0.00 CFD Payoff Fee $0.00 PFF (3105540} $0.00 PFF (4305540) $0.00 License Tax (3104193) $0.00 License Tax (4304193) $0.00 Traffic Impact Fee (3105541) $0.00 Traffic Impact Fee {4305541) $0.00 Sidewalk Fee $0.00 PLUMBING TOTAL $0.00 ELECTRICAL TOTAL $0.00 MECHANICAL TOTAL $0.00 Housing Impact Fee ?? Housing InLieu Fee $0.00 Housing Credit Fee Master Drainage Fee $0.00 Sewer Fee $0.00 Additional Fees TOTAL PERMIT FEES $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $567.50 Total Fees:$567.50 Total Payments To Date:$567.50 Balance Due:$0.00 Inspector: FINAL APPROVAL Date:Clearance: NOTICE: Please take NOTICE that approval of your project includes the "Imposition* of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired. . PERMIT APPLICATIONCITY OF CARLSBAD BUILDING DEPARTMENT2075 Las Palmas Dr., Carlsbad CA 92009(760)438-1161 FOR OFFICE USE ONLYPLAN CHECKEST. VAL.Plan Ck. DepositValidated ByDateAddress (include BIdg/Suite Business Name (at this 06/29/99 0001 01 02Phase NCrPKtfhotal # of unHST-50Legal Description Lot No.Subdivision Name/Number Unit No.Assessor's Parcel #<$Y Af&fa Existing Use Proposed UseDescription of Work SO. FT.#of Stories # of Bedrooms # of Bathrooms (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law [Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code] or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars [45001). Name Address State License # License Class City State/Zip Telephone # City Business License # Designer Name Address State License # 6. i ;;WORKER'S1 ;qOHJPENSAtlO'N^£::: •> .. '•; ••.•"•.. '*•.>.-.•< '-'= -, ,'.: : '.}" City State/Zip Telephone Workers' Compensation Declaration: I hereby affirm under penalty of perjury one of the following declarations: n I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. Q I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My worker's compensation insurance carrier and policy number are: Insurance Company _ Policy No. _ Expiration Date _ (THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS [$1001 OR LESS) Q CERTIFICATE OF EXEMPTION: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. WARNING: Failure to secure workers' compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars ($100,000), in addition to the cost of compensation, damages as provided for in Section 3706 of the Labor code, interest and attorney's fees. SIGNATURE DATE I hereby affirm that I am exempt from the Contractor's License Law for the following reason: D I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). JO***!, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). O I am exempt under Section _ Business and Professions Code for this reason: 1 . I personally plan to provide the major labor and materials for construction of the proposed property improvement. Q YES 2. I (Have)/ have not) signed an application for a building permit for the proposed work. 3. I have contracted with the following person (firm) to provide the proposed construction (include name / address / phone number / contractors license number): 4. I plan to provide portions of the work, but 1 have hired the following person to coordinate, supervise and provide the major work (include name / address / phone number / contractors license number): 5. I will provide some of the work, but \ have contracted (hired) the following persons to provide the work indicated (include name / address / phone number / type of work): PROPERTY OWNER SIGNATURE Is the applicant or future building acc\ip_ai\t/equired to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? Q YES C! NO Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? O YES Q NO Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? Q YES Q NO IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT.ta:;n$p$^ ..=• . /^^T-^V^:- ;.--.• . • •. / .-= -,: . >.- ••• / , •••; . .-.•• •:r.vtyv I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3Q97(i) Civil Code). LENDER'S NAME LENDER'S ADDRESS I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate, I agree to comply with all City ordinances and State laws relating to building construction. I hereby authorize representatives of the CitV of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: An OSHA permit is required for excavations over 5'0" deep and demolition or construction of structures over 3 stories in height. EXPIRATION: Every permit issued by the ByUd>Fi!? Off icial under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is not co^RmftrfcHtfwithinyjeffdays from the date of such permit or if the buitding or work authorized by such permit is suspended or abandoned at any time after the woj]p>^$nvfiencejHprj^period o^^TBQxIays (Section 106.4.4 Uniform Building Code). • APPLICANT'S SIGNATURE DATE MITE: File YELLOW: Applicant PINK: Finance EsGil Corporation In Partners/lip with, government for Quitting Safety DATE: 11/29/99 QAPPa^ANT JURISDICTION: Carlsbad a PLAN REVIEWER a FILE PLAN CHECK NO.: 99-2396 SET: IV PROJECT ADDRESS: 2815 Elmwood St. PROJECT NAME: Courson-Gonsalez Residential Addition The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: Esgil Corporation staff did not advise the applicant (except by mail) that the plan check has been completed. Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Telephone #: Date contacted: (by: ) Fax #: Mail Telephone Fax In Person REMARKSrA. Special iiispectteFHs^Qq^Hred for the epoxy set hold dowfl-keJte-tfHhgrexrsting^^^™ i i i I W •*+ foundation ThP-architect or Anrjinp^i1 nfimmtshall prepare an inspection prngrnrii wliiHi si i nil In* submitted to tho building official-for approval prtorto issuance of tho building PGM nit. Please review Section 106.3.5. Please complete the attached form. B. The attached sheets 11,17 & S-1 must be incorporated into the city set of plans By: Chuck Mendenhall Enclosures: Esgil Corporation D GA n MB D EJ D PC 11/16/99 tmsmtl.dot SPECIAL INSPECTION PROGRAM ADDRESS OR LEGAL DESCRIPTION: PLAN CHECK NUMBER: OWNER'S NAME: I, as the owner, or agent of the owner (contractors may not employ the special inspector), certify that I, or the architect/engineer of record, will be responsible for employing the special inspector(s) as required by Uniform Building Code (UBC) Section 1701.1 for the construction project located at the site listed above. UBC Section 106,3.5. Signed I, as the engineer/architect of record, certify that I have prepared the following special inspection program as required by UBC Section 106.3.5 for the construction project located at the site listed above. EngineerVArchftael's SealBwe Signed 1. List of work requiring special inspection: Q Soils Compliance Prior to Foundation Inspection Q Field Welding n Structural Concrete Over 2500 PSI O High Strength Bolting Q Prestressed Concrete Q Expansion/Epoxy Anchors Q Structural Masonry Q] Sprayed-On Fireproofing Q] Designer Specified G Other 2. Name(s) of individual(s) or firm(s) responsible for the special inspections listed above: A. B. C. 3. Duties of the special inspectors for the work listed above: A. B. C. Special inspectors shall check in with the City and present their credentials for approval prior to beginning work on the job site. EsGil Corporation In fartwrsfiip with Qovtrnmtnt for 'BuiOfing Safety DATE: 11/4/99 Q APPLjCANT JURISDICTION: Carlsbad Q PLAN REVIEWER a FILE PLAN CHECK NO.: 99-2396 SET: III PROJECT ADDRESS: 2815 Elmwood St. PROJECT NAME: Courson-Gonsalez Residential Addition The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: Plato Carpadakis 3169 Chelea Park Circle, Spring valley, CA 91976 Esgil Corporation staff did not advise the applicant (except by mail) that the plan check has been completed. Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Telephone #: Date contacted: (by: ) Fax #: Mail Telephone Fax In Person REMARKS: By: Chuck Mendenhall Enclosures: .,, Esgil Corporation D GA D MB n EJ n PC 10/28/99 tmsmtwot 9320 Chesapeake Drive, Suite 208 4 San Diego, California 92123 4 (858)560-1468 4 Fax (858) 560-1576 Carlsbad 99-2396 11/4/99 NOTE: The items listed below have not been adequately addressed. I hope you don't intend to further delay this project by attempting to respond to the remaining items as "overkill" and questioning the professional judgement of the soil engineer. This evasion of the issues by name calling and conjecture does nothing to further your clients desire to secure a building permit. • PLANS 1. Please make all corrections on the original tracings, as requested in the correction list. Submit three sets of plans for commercial/industrial projects (two sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 2075 Las Palmas Drive, Carlsbad, CA 92009, (760) 438-1161. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. 2. Special inspection is required for the epoxy set hold down bolts in the existing foundation. The architect or engineer of record shall prepare an inspection program which shall be submitted to the building official for approval prior to issuance of the building permit. Please review Section 106.3.5. Please complete the attached form. The city does have a copy of the Special inspection Program on file but it has not been completed. The company that will be performing the inspections must be listed prior to issuance of the building permit. • FOUNDATION REQUIREMENTS 11. In accordance with Carlsbad policy provide a copy of the project soil report prepared by a California licensed architect or civil engineer. The report shall include foundation design recommendations based on the engineer's findings and shall comply with UBC Section 1804. The soil report has * now been provided but the following items are required by the report: Carlsbad 99-2396 11/4/99 A. The soils engineer recommended that he/she review the foundation excavations. Note on the foundation plan that "Prior to the contractor requesting a Building Department foundation inspection, the soils engineer shall advise the building official in writing that: • The building pad was prepared in accordance with the soils report, • The utility trenches have been properly backfilled and compacted, and • The foundation excavations, the soils expansive characteristics and bearing capacity conform to the soils report." B. Provide a letter from the soils engineer confirming that the foundation plan, grading plan and specifications have been reviewed and that it has been determined that the recommendations in the soils report are properly incorporated into the construction documents (required by the soil report). C. The footings must be at least 18" into competent terrace deposits. The foundation details on sheet S1 show the footings to be max of 12" deep. SHEET 11 OF THE PLANS HAS BEEN CHANGED TO INDICATE THE 18" DEEP FOOTINGS BUT THE DETAILS ON SHEET 17 OF THE PLANS. To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Chuck Mendenhall at Esgil Corporation. Thank you. EsGil Corporation In yartneTsfiip with government for 'BuiUing Safety DATE: 10/5/99 Q APPLICANT Jl JURISDICTION: Carlsbad a~PLSFJ"REVlEWER a FILE PLAN CHECK NO.: 99-2396 SET: II PROJECT ADDRESS: 2815 Elmwood St. PROJECT NAME: Courson-Gonsalez Residential Addition The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: Plato Carpadakis 3169 Chelea Park Circle, Spring valley, CA 91976 Esgil Corporation staff did not advise the applicant (except by mail) that the plan check has been completed. Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Telephone #: Date contacted: (by: ) Fax #: Mail Telephone Fax In Person REMARKS: By: Chuck Mendenhall Enclosures: Esgil Corporation GA MB EJ PC 9/27/99 trnsmtl.dot 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 4 (858)560-1468 4 Fax (858) 560-1576 Carlsbad 99-2396 10/5/99 NOTE: The item numbers listed below refer to the items from the previous list. These remaining items have not been adequately addresses. The note in bold a the end of each item is to emphasize the remaining problem. • PLANS 1. Please make all corrections on the original tracings, as requested in the correction list. Submit three sets of plans for commercial/industrial projects (two sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 2075 Las Palmas Drive, Carlsbad, CA 92009, (760) 438-1161. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. 2. Special inspection is required for the epoxy set hold down bolts in the existing foundation. The architect or engineer of record shall prepare an inspection program which shall be submitted to the building official for approval prior to issuance of the building permit. Please review Section 106.3.5. Please complete the attached form. Special inspection program form was not provided. • FOUNDATION REQUIREMENTS 11. In accordance with Carlsbad policy provide a copy of the project soil report prepared by a California licensed architect or civil engineer. The report shall include foundation design recommendations based on the engineer's findings and shall comply with UBC Section 1804. The soil report has now been provided but the following items are required by the report: A. The soils engineer recommended that he/she review the foundation excavations. Note on the foundation plan that "Prior to the contractor requesting a Building Department foundation inspection, the soils engineer shall advise the building official in writing that: • The building pad was prepared in accordance with the soils report, Carlsbad 99-2396 10/5/99 • The utility trenches have been properly backfilled and compacted, and • The foundation excavations, the soils expansive characteristics and bearing capacity conform to the soils report." B. Provide a letter from the soils engineer confirming that the foundation plan, grading plan and specifications have been reviewed and that it has been determined that the recommendations in the soils report are properly incorporated into the construction documents (required by the soil report). C. The footings must be at least 18" into competent terrace deposits. The foundation details on sheet S1 show the footings to be max of 12" deep. • ENERGY CONSERVATION 22. All energy items shown on the plans must be in agreement with the information shown on the properly completed Form CF-IR. The energy design does not include a new or additional water heater. The plans show a proposed additional WH in the new garage. THE RESPONSE INDICATES THAT 12 ON S1 ONLY REFERS TO AN ADDITIONAL WH IF NECESSARY. THE PLANS SHOW A SHADED WH IMPLYING THAT AN ADDITIONAL WH IS ACCEPTABLE. THIS IS NOT THE CASE. THE ENERGY DESIGN DOES NOT INCLUDE A NEW WATER HEATER. DELETE THIS NOTE AND DETAIL FROM THE PLANS OR PROVIDE REVISED ENERGY DESIGN. To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please indicate: Yes Q No a The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Chuck Mendenhall at Esgil Corporation. Thank you. Carlsbad 99-2396 10/5/99 SPECIAL INSPECTION PROGRAM ADDRESS OR LEGAL DESCRIPTION: PLAN CHECK NUMBER: OWNER'S NAME: I, as the owner, or agent of the owner (contractors may not employ the special inspector), certify that I, or the architect/engineer of record, will be responsible for employing the special inspector(s) as required by Uniform Building Code (UBC) Section 1701.1 for the construction project located at the site listed above. UBC Section 106.3.5. Signed I, as the engineer/architect of record, certify that I have prepared the following special inspection program as required by UBC Section 106.3.5 for the construction project located at the site listed above. EnglneerVArcWect'a Seal & Signature Signed 1. List of work requiring special inspection: Q Soils Compliance Prior to Foundation Inspection O Field Welding n Structural Concrete Over 2500 PSI n High Strength Bolting G Prestressed Concrete Q Expansion/Epoxy Anchors Q Structural Masonry Q Sprayed-On Fireproofing Q| Designer Specified Q Other 2. Name(s) of individual(s) or firm(s) responsible for the special inspections listed above: A. B. C. 3. Duties of the special inspectors for the work listed above: A. B. C. EsGil Corporation In ^Partners/lip vJitfi. government for ftuihting Safety DATE: 7 V 15/99 JURISDICTION: Carlsbad Q PLAN REVIEWER Q FILE PLAN CHECK NO.: 99-2396 SET: I PROJECT ADDRESS: 2815 Elmwood St. PROJECT NAME: Courson-Gonsalez Residential Addition The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: Plato Carpadakis 3169 Chelea Park Circle, Spring valley, CA 91976 Esgil Corporation staff did not advise the applicant (except by mail) that the plan check has been completed. Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Telephone #: Date contacted: (by: ) Fax #: Mail Telephone Fax In Person REMARKS: By: Chuck Mendenhall Enclosures: Esgil Corporation D GA D MB D EJ D PC 7/1/99 tmsmldot 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858)560-1468 •* Fax (858) 560-1576 Carlsbad 99-2396 7/15/99 PLAN REVIEW CORRECTION LIST SINGLE FAMILY DWELLINGS AND DUPLEXES PLAN CHECK NO.: 99-2396 JURISDICTION: Carlsbad PROJECT ADDRESS: 2815 Elmwood St. FLOOR AREA: 1754 New REMARKS: DATE PLANS RECEIVED BY JURISDICTION: DATE INITIAL PLAN REVIEW COMPLETED: 7/15/99 STORIES: two HEIGHT: 23 ft approx per UBC DATE PLANS RECEIVED BY ESGIL CORPORATION: 7/1/99 PLAN REVIEWER: Chuck Mendenhall FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinance by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Present California law mandates that residential construction comply with Title 24 and the following model codes: 1994 UBC (effective 12/28/95), 1994 UPC (effective 12/28/95), 1994 UMC (effective 2/23/96) and 1993 NEC (effective 12/28/95). The above regulations apply to residential construction, regardless of the code editions adopted by ordinance. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3, 1994 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans. Carlsbad 99-2396 7/15/99 • PLANS 1. Please make all corrections on the original tracings, as requested in the correction list. Submit three sets of plans for commercial/industrial projects (two sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 2075 Las Palmas Drive, Carlsbad, CA 92009, (760) 438-1161. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. 2. Special inspection is required for the epoxy set hold down bolts in the existing foundation. The architect or engineer of record shall prepare an inspection program which shall be submitted to the building official for approval prior to issuance of the building permit. Please review Section 106.3.5. Please complete the attached form. • GENERAL RESIDENTIAL REQUIREMENTS 3. Glazing in the following locations should be of safely glazing material in accordance with Section 2406.4 A. window 16 at the stair enclosure B. Windows 11 & 12 at the master tub. C. Window 8 within 24" of the sliding glass door at the Master Sitting Rm • EXITS, STAIRWAYS, AND RAILINGS 4. Guardrails (Section 509.1): a) Openings between railings shall be less than 4". See the rail above the Living Rm shown in section A/9. It appears that the rail above the stem wall has openings greater than 4". 5. The handgrip portion of all handrails shall be not less than 1-1/4 inches nor more than 2 inches in cross-sectional dimension. Handrails projecting from walls shall have at least 1-1/2 inches between the wall and the handrail. Section 1006.9. See section A/10. Carlsbad 99-2396 7/15/99 15. Design and detail on the plans the second floor support for beam R-2 (4x10) over the Guest Bed Rm closet. The plans do not show support for the post supporting this beam. 16. Detail on the plans the connection of the second floor Cs strap hold downs to the beam or joists below. Detail the connection of these beams or joists to the post support to resist the uplift forces. • MECHANICAL (UNIFORM MECHANICAL CODE) 17. Show the size, location and type of the new heating and cooling appliances or systems. 18. Show source of combustion air to furnace, per Chapter 7, UMC. 19. Show access to the attic containing equipment to be minimum 30 inches by 30 inches. The opening may be 22 inches by 30 inches if the equipment can be removed through such opening. Section 319.3, UMC. 20. Note that passageway to the attic furnace shall be unobstructed and have continuous solid flooring not less than 24 inches wide, not more than 20 feet in length through the attic. Section 319.4, UMC. • ELECTRICAL (NATIONAL ELECTRICAL CODE) 21. Show on the plan the existing or new amperage of the electrical service, the location of the service panel and the location of any sub-panels. If service is over 200 amps, submit single line diagram, panel schedule and load calculations. • ENERGY CONSERVATION 22. All energy items shown on the plans must be in agreement with the information shown on the properly completed Form CF-IR. The energy design does not include a new or additional water heater. The plans show a proposed additional WH in the new garage. 23. Show on the plans the make, model, type and efficiency of the space heating (or cooling) system. • CARLSBAD S.F.P. & DUPLEX SUPPLEMENT 24. All structures require a Class A roof covering, except room additions. If a room addition covers all of the existing building (2nd story addition), then the above exception doesn't apply. Carlsbad 99-2396 7/15/99 SPECIAL INSPECTION PROGRAM ADDRESS OR LEGAL DESCRIPTION:ce PLAN CHECK NUMBER:OWNER'S NAME: 79&**A-£ '• as the owner, or agent of the owner (contractors may not employ the special inspector), certify that I, or the architect/engineer of record, will be responsible for employing the special inspector(s) as required by Uniform Building Code (UBC) Section 1701.1 for the construction project located atthje site listed above. UBC Section 106.3.5. Signe.AA/W I, as the engine'er/arfcbntect of record, certify that I have prepared the following special inspection program as required by UBC Section 106.3.5 for the construction project located at the site listed above. Enginear't/AirNlMft Seal & Signature Here Signed 1. List of work requiring special inspection: Q Soils Compliance Prior to Foundation inspection Q Field Welding D Structural Concrete Over 2500 PSI iHign Stren9tn Bolting O Prestressed Concrete f_ g)Expansion/Epoxy Anchors n Structural Masonry ^-^^"_T Sprayed-On Fireproofing Q Designer Specified Q Other 2. Name(s) of individual(s) or firm(s) responsible for the special inspections listed above: A J & * A.^^^ m^^^L-^rkA -J^-^^*^^^ 1 ^^* m^* * — — . -^ ^ ^ - ^^ i-T—_•* * ^ -A 9 B. c. 3. Duties of the special inspectors for the work listed above: A. B. C. Special inspectors shall check in with the City and present their credentials for approval prior to beginning work on the job site. Carlsbad 99-2396 7/15/99 VALUATION AND PLAN CHECK FEE JURISDICTION: Carlsbad PREPARED BY: Chuck Mendenhall BUILDING ADDRESS: 2815 Elmwood St. BUILDING OCCUPANCY: R3/U1 PLAN CHECK NO.: 99-2396 DATE: 7/15/99 TYPE OF CONSTRUCTION: VN BUILDING PORTION Dwelling Garage Air Conditioning Fire Sprinklers TOTAL VALUE BUILDING AREA (ft.2) 1754 608 VALUATION MULTIPLIER City Est City Est VALUE ($) 171,892 n 199 UBC Building Permit Fee • Bldg. Permit Fee by ordinance: $ 873.07 D 199 UBC Plan Check Fee • Plan Check Fee by ordinance: $ 567.49 Type of Review: Q Complete Review Q Structural Only Q Hourly Q Repetitive Fee Applicable Q Other: Esgil Plan Review Fee: $ 453.99 Comments: Sheet 1 of 1 macvalue.doc 5196 City of Carlsbad Engineering Department DATE: BUILDING PLANCHECK CHECKLIST PLANCHECK NO.: CB BUILDING ADDRESS: _ PROJECT DESCRIPTION: ASSESSOR'S PARCEL NUMBER: ff-ftV ENGINEERING DEPARTMENT APPROVAL The item you have submitted for review has been approved. The approval is based on plans, information and/or specifications provided in your submittal; therefore any changes to these items after this date, including field modifications, must be reviewed by this office to insure continued conformance with applicable codes. Please review carefully all comments attached, as failure to comply with instructions in this report can result in suspension of permit to build. LA Right-of-Way permit is required prior to construction of the following improvements: EST. VALUE: DENIAL Please see ,the.attached report of deficiencies marked with^Br'^ake necessary corrections to plans or specifications for compliance with applicable codes and standards. Submit corrected plans and/or specifications to this office for review. Date: T By: FOR OFFICIAL USE ONLY ENGINEERING AUTHORIZATION TO ISSUE BUILDING PERMIT: Date: D D n n ATTACHMENTS Dedication Application Dedication Checklist Improvement Application Improvement Checklist Future Improvement Agreement Grading Permit Application Grading Submittal Checklist Right-of-Way Permit Application Right-of-Way Permit Submittal Checklist and Information Sheet Sewer Fee Information Sheet ENGINEERING DEPT. CONTACT PERSON Name: JOANNE JUCHNIEWICZ City of Carlsbad Address: 2075 Las Palmas Dr., Carlsbad, CA 92009 Phone: (619)438-1161, ext. 4510 CFD INFORMATION Parcel Map No: Lots: Recordation: Carlsbad Tract: A-4 . CA 92OO9-^576 • (76O) 438-1161 • FAX (76O) BUILDING PLANCHECK CHECKLIST SITE PLAN 1. Provide a fully dimensioned site plan drawn to scale. Show: North Arrow D. Property Lines Existing & Proposed Structures E. Easements listing Street Improvements F. Right-of-Way Width & Adjacent Streets G. Driveway widths Q 2. Show on site plan: A. Drainage Patterns 1. Building pad surface drainage must maintain a minimum slope of one percent towards an adjoining street or an approved drainage course. 2. ADD THE FOLLOWING NOTE: "Finish grade will provide a minimum positive drainage of 2% to swale 5' away from building." B. Existing & Proposed Slopes and Topography H 3. Include on title sheet: A. Site address B. Assessor's Parcel Number C. Legal Description For commercial/industrial buildings and tenant improvement projects, include: total building square footage with the square footage for each different use, existing sewer permits showing square footage of different uses (manufacturing, warehouse, office, etc.) previously approved. EXISTING PERMIT NUMBER DESCRIPTION DISCRETIONARY APPROVAL COMPLIANCE Q Q 4a. Project does not comply with the following Engineering Conditions of approval for Project No. Q Q 4b. All conditions are in compliance. Date: H \WORD\DOCS\CHKLSTiBuikling Planchecfc CKlsl BP0001 Fomi JJ.doc BUILDING PLANCHECK CHECKLIST DEDICATION REQUIREMENTS 5. Dedication for all street Rights-of-Way adjacent to the building site and any storm drain or utility easements on the building site is required for all new buildings and for remodels with a value at or exceeding $ , pursuant to Carlsbad Municipal Code Section 18.40.030. Dedication required as follows: Dedication required. Please have a registered Civil Engineer or Land Surveyor prepare the appropriate legal description together with an 8 Vz" x 11" plat map and submit with a title report. All easement documents must be approved and signed by owner(s) prior to issuance of Building Permit. Attached please find an application form and submittal checklist for the dedication process. Submit the completed application form with the required checklist items and fees to the Engineering Department in person. Applications will not be accept by mail or fax. Dedication completed by:Date: IMPROVEMENT REQUIREMENTS 6a. All needed public improvements upon and adjacent to the building site must be constructed at time of building construction whenever the value of the construction exceeds $ ^O gt?o pursuant to Carlsbad Municipal Code Section 18.40.040. ^ Public improvements required as follows: Attached please find an application form and submittal checklist for the public improvement requirements. A registered Civil Engineer must prepare the appropriate improvement plans and submit them together with the requirements on the attached checklist to the Engineering Department through a separate plan check process. The completed application form and the requirements on the checklist must be submitted in person. Applications by mail or fax are not accepted. Improvement plans must be approved, appropriate securities posted and fees paid prior to issuance of building permit. Improvement Plans signed by:Date: 6b. Construction of the public improvements may be deferred pursuant to Carlsbad Municipal Code Section 18.40. Please submit a recent property title report or current grant deed on the property and processing fee of $ tZL&Q^* so we may prepare the necessary Future Improvement Agreement. This agreement must be signed, notarized and approved by the City prior to issuance of a Building permit. Future public improvements required as follows: H:\WORD\DOCS\CHKLST\fluiMina PlanOieck Cklsl BP0001 Form JJ.doc BUILDING PLANCHECK CHECKLIST •i st^ ond^ QftJ^ Q Q Q 6c. Enclosed please find your Future Improvement Agreement. Please return agreement signed and notarized to the Engineering Department. Future Improvement Agreement completed by: Date: Q Q a 6d. No Public Improvements required. SPECIAL NOTE: Damaged or defective improvements found adjacent to building site must be repaired to the satisfaction of the City Inspector prior to occupancy. GRADING PERMIT REQUIREMENTS The conditions that invoke the need for a grading permit are found in Section 11.06.030 of the Municipal Code. Q Q Q 7a. Inadequate information available on Site Plan to make a determination on grading requirements. Include accurate grading quantities (cut, fill import, export). Q Q Q 7b. Grading Permit required. A separate grading plan prepared by a registered Civil Engineer must be submitted together with the completed application form attached. NOTE: The Grading Permit must be issued and rough grading approval obtained prior to issuance of a Building Permit. Grading Inspector sign off by: Date: Q Q 7c. Graded Pad Certification required. (Note: Pad certification may be required even if a grading permit is not required.) Q Q 7d.No Grading Permit required. Q Q 7e.lf grading is not required, write "No Grading" on plot plan. MISCELLANEOUS PERMITS Q 8. A RIGHT-OF-WAY PERMIT is required to do work in City Right-of-Way and/or private work adjacent to the public Right-of-Way. Types of work include, but are not limited to: street improvements, free trimming, driveway construction, tieing into public storm drain, sewer and water utilities. Right-of-Way permit required for: BUILDING PLANCHECK CHECKLIST HAWORD\DOCS\CHKLST^Buikling Plancheck Cklst BP0001 Form JJ.doc t PLANNING DEPARTMENT BUILDING PLAN CHECK REVIEW CHECKLIST Address Planner APN: Phone (619) 438-1 1 61 , extension I \ Type of Project & Use:_ Zoning: r* General Plan: Project Density:.DU/AC Facilities Management Zone: CFD fin/nut) Circle One .Date of participation:Remaining net dev acres: (For non-residential development: Type of land used created by this permit: ) Legend:Item Complete Environmental Review Required: DATE OF COMPLETION: YES Item Incomplete - Needs your action NO TYPE Compliance with conditions of approval? If not, state conditions which require action. Conditions of Approval: Discretionary Action Required: APPROVAL/RESO, NO. PROJECT NO. YES NO TYPE DATE OTHER RELATED CASES: Compliance with conditions or approval? If not, state conditions which require action. Conditions of Approval: Coastal Zone Assessment/Compliance XProject site locateoin Coastal Zone? CA Coastal Commissl&n Authority? YES If California Coastal Commission Authority: Contact them at - 3111 C 200, San Diego CA 92108-17^; (619) 521-8036 Determine status (Coastal Perrhjt Required or Eyerrtpt): Coastal Permit Determination FornXalreadV^completed? YESv- Form now. rI 6t>el Rio North, Suite <r<tfe*/J If NO, complete Coastal Permit Determine Coastal Permit Determinatiqp^tog #:f Follow-Up Actions^ 1) StampBdNding Plans as "Exempt" or "Coas\^[ Permit Required" (at minimum FloprTlans). 2) .Complete Coastal Permit Determination Log as neei Carlsbad 99-2396 7/15/99 6. Stairway within the garage adjacent to the entry and landing must be a min of 36" wide. Sections 1006.3,1006.15 and 1006.2. • ROOFING 7. Specify new roof material and application. Chapter 15. 8. Specify on the plans the following information for the roof materials, per Section 106.3.3: • Manufacturer's name. • Product name/number. • ICBO approval number, or equal. 9. Show attic ventilation. Minimum vent area is 1/150 of attic area (or 1/300 of attic area if at least 50% of the required vent is at least 3 feet above eave vents or cornice vents). Show area required and area provided. Section 1505.3. • GARAGE AND CARPORTS 10. New part of garage requires one-hour fire protection on the garage side of walls and ceiling common to the dwelling. Table 3-B, Section 302.4. I could not locate the required fire protection adjacent to the Entry and along the breezeway. • FOUNDATION REQUIREMENTS 11. In accordance with Carlsbad policy provide a copy of the project soil report prepared by a California licensed architect or civil engineer. The report shall include foundation design recommendations based on the engineer's findings and shall comply with UBC Section 1804. 12. Hold downs are required by the design engineer, note on plan that hold down anchors must be tied in place prior to foundation inspection. Section 108.5.2. 13. Include in the foundation design the continuous footing supporting the concentrated cantilever load from beam FB-3 that has a reaction of 4845 Ibs • FRAMING 14. Per UBC Section 2343.6, provide the following note on the plans if trusses are used: "Each truss shall be legibty branded, marked or otherwise have permanently affixed thereto the following information located within 2 feet of the center of the span on the face of the bottom chord: • Identity of the company manufacturing the truss. • The design load. • The spacing of the trusses." ord/G Q 9. A SEWER PERMIT is required concurrent with the building permit issuance. The fee is noted in the fees section on the following page. Q 10. INDUSTRIAL WASTE PERMIT If your facility is located in the City of Carlsbad sewer service area, you need to contact the Carlsbad Municipal Water District, located at 5950 El Camino Real, Carlsbad, CA 92008. District personnel can provide forms and assistance, and will check to see if your business enterprise is on the EWA Exempt List. You may telephone (760) 438-2722, extension 153, for assistance. Industrial Waste permit accepted by: Date: Q 11.NPDES PERMIT Complies with the City's requirements of the National Pollutant Discharge Elimination System (NPDES) permit. The applicant shall provide best management practices to reduce surface pollutants to an acceptable level prior to discharge to sensitive areas. Plans for such improvements shall be approved by the City Engineer prior to issuance of grading or building permit, whichever occurs first. Q Q 12. Q Required fees are attached Q^No fees required Q a a 13. Additional Comments: H:\WORD\DOCS\CHKLSTiSuiMing PlanchecK ClUsl BP0001 Fofm JJ.doc D Inclusionary Housing Fee required: YES NO (Effective date of Inclusionary Housing Ordinance - May 21, 1993.) Data Entry Completed? YES NO (A/P/Ds, Activity Maintenance, enter CB#, toolbar. Screens, Housing Fees, Construct Housing Y/N, Enter Fee, UPDATE!) Site Plan: 1. Provide a fully dimensional site plan drawn to scale. Show: North arrow, property lines, easements, existing and proposed structures, streets, existing street improvements, right-of-way width, dimensional setbacks and existing topographical lines. 2. Provide legal description of property and assessor's parcel number. Zoning: 1. Setbacks: Front: Interior Side: Street Side: Rear: Required Required Required Required Shown Shown Shown Shown .'V i 2. Accessory structure setbacks: Front: Requirej Interior Side: Street Side: ^^^^ Required Rear: ^^ Required Structtffe separation: Required 3. Lot Coverage:Required Shown Shown Shown Shown Shown Shown 4. Height:Required Shown 5. Parking: Spaces Required Guest Spaces Required Additional Comments_ Shown Shown OK TO ISSUE AND ENTERED APPROVAL INTO COMPUTER November 19, 1999 Mr. Michael Holzmiller Planning Director Carlsbad Planning Department 2075 Las Palmas Drive Carlsbad, CA 92009-1576 Re: PF#CB 992396 Residential addition - 2815 Elmwood St. Dear. Mr. Holzmiller: In accordance with para. 21.10.040 (A) (2) (side yards), I respectfully request that the north side yard of this proposed project be reduced to nine (9) feet since the South and opposite side yards is already eleven (11) feet. In addition, the existing adjacent residences to the north and south are already 12 ft. & 16 ft. respectively. This would appear to be adequate separations after completion of the project. I thank you in advance for your consideration and hopeful approval. Sincerely, Kelly Courson 2815 Elmwood St. Carlsbad, CA 92008 (760) 729-7758 with 11ISOP? VTIU tl TIDCI UAtt TK it ran Kin tun m •MB.I •inm tm «vi.1 Lift or TVCT lit «rLI ii nc iirrict « ID •H, i iinm of iii.« M I # " ^ j^ ^n^ V \jf / ^ v *g / 5\ 3 ' I 5 S 1 ^ 'o ' fe < ;" i "V • i" ' h tit ""h'"nrT 1 • •s \V ' . MEW \\ I ^...•\T . /["}"» s. -2,5 /-* - - - i ' V ' (T v ^s i \ 1 \ ~ : V.\ \ N \VA - ^*"~ lOO.OO' MOKTH \ o' i-201 O fcXKT^ -.'-. f. -\ -\ ' ]X;T )\\ fJ;/ I , I/ "\ 1 '• ' \. i SITE PLAKJ c -) EXPRESS LIMITATION OF LIABILITY: permitted by law, Design to Owner for any and all expenses or damages whats in anyway related to this Contract from any cause o not limited to Designer's omissions, strict liabili breach of warranty shall received by Designer's or Services. er's total liability injuries, claims, losses oever arising out of or project or to the original r causes including, but negligence , errors , ty, breach of contract or not exceed the total compensation iginal contract for Basic , / ,\ 1) The Contractor iluwork and Omtr ilutUttnclti. Z) All calttloM »nd4riw1nfl> and/or mtlon btfori prKii 3) Thi appropriate ciIn th« *na to b* 4) Ownar th*ll not fr of thli prejact oaccordanc* with t t) Should tha contraawar* of any faul•rrori, aHblgultlfor which proportnanof to tha OHprojact In ordtr 61 All wortuaanthlp,raqulroBanti of tapplied or conitrttandardi of tha 7) Dlawniloni, locatvarUtad with arcappropriate. B) Uhtr* no construeth* datifli tnall 9) Notes and detail*notei ind dttalltpr««d«nc« o»ar i 10) All twlcal detal 11) Ho p1p«t or duct iUtlcd for that p 12) All Contractors irovlewtd and-undiraa>111arUy with,accoapllih and ctJ*ct to th* coup) 13) Substitutions toetc. cither in quttnt thereof Mythe Owfer. 14) All KITCHEN APFU 15} The entire habit* with gti-f Ircd tocontroh, ttc. th•anlikt awaner tx GENERAL H Q/l . Thi« pro]e TOUB OAT IONS F/l Wood shall 1 F/2 Surface watt F/3 Where hold < in plac* p* F/4 where Ht f provide a 1' vail. F/S Provide Hln bolt*. 6 f<. ' one bolt lo. T/6 Foundation* or equal. FRAMING FR/1 Where Glued certificate shall be glv to inatallat FR/2 All WtATBER- realstive b( cover! no Bticflashed In > proof . FB/3 Where trum branded . mat •ffixftd thei within 2 fe< of th* bott< a- Identil b- the dei c- the tpi FR/* NAILING will FIRE PROTECTI FP/1 Permanently hai-lrnr, shall Kenneth H. Barrett OWL ENGINEER, CE-14659 P. 0. Box 12695 El Cajon, CA 92022 (619) 442-5864 4/1? 2} A} o/ 6) /i-f- Of- -- X 3 /: - 9' XM -® ' O Structural Consulta /O Kenneth H. Barrett CIVIL ENGINEER, CE-14659 P. 0. Box 12695 El Cajon, CA 92022 (619) 442-5864 ft! "7<i ,// 3.02/2* 2029 /-f - 5 ' 4* <+ * 1 Of - 6 0 -f £ 0 Structural Consultant Kenneth H. Barrett CML ENGINEER, CE-14659 P. 0. Box 12695 Et Cajon, CA 92022 (619) 442-5864 /..IS 7-- /to* W',*> .- 9 - & <L- 10 - $.(, p* 3/20 /) 3) 0 0/u /T SO I 7 X-//- t structural Consultant n' t 0 f A Kenneth H. Barrett C/V/L ENGINEER, CE-14659 P. 0. Box 12695 El Cajon, CA 92022 (619) 442-5864 AS -7' Cttt-1.fr # - "7 Structural Consultant Kenneth H. Barrett CIVIL ENGINEER, CE-14659 P. 0. Box 12695 El Cajon, CA 92022 - /f 4-6 1 s) 4 i 7 7^ <? ' Structural Consultant 7) A &M|S f 4' II +O 3560 C) •7 Kenneth H. Barrett CIVIL ENGINEER, CE-14659 P. 0. Box 12695 El Cajon, CA 92022 (619) 442-5864 Af Z(.l f<*/fe*,g3* w. 301 $J 4 * 1- Of 2 Structural Consultant 9.5 727 Kenneth H. Barren CIVIL ENGINEER, CE-14659 P. O. Box 12695 El Cajon, CA 92022 (619) 442-5864 t/L* 34/2 oa 3 ^ ^ ^ /35 Structural Consultant - Q ' 2 0 f~ 2*lt*2()f Kenneth H. barren CIVIL ENGINEER, CE-14659 P. 0. Box 12695 El Cajon, CA 92022 (619) 442-5864 P* StSO IMZft //f 257* J3//5-9 -5' I-A; 356(5 * 461* if -5 '- * I Of Structural Consultant Kennein ti. barren CIVIL ENGINEER, CE-14659 P. 0. Box 12695 El Cajon, CA 92022 442-5864 £-3235 & L 6 - c- tf/2 - 310 flf - 7 J 125 " /iz B'tf 03 f IB- E c' V-$ I - /2" — a t\ X 4 ' . 2. Structural Consultant Kenneth H. Barrett CIVIL ENGINEER, CE-14659 P. O. Box 12695 El Cajon, CA 92022 (619)442-5864 * 4 J i 2,52 y -- £f-Btf^A . /J"^ /5 tul&f- /8 " Structural Consultant I'll, Kenneth H. Barrett CIVIL ENGINEER, CE-14659 P. 0. Box 12695 El Cajon, CA 92022 (619) 442-5864 3co * 2/5 -11 24332. 14- * -^ 4I3CZ Structural Consultant ' v^/X ZS.C* "- 41. f- - /a) 0 Kenneth H. Barrett CIVIL ENGINEER, CE-14659 P. O. Box 12695 El Cajon, CA 92022 (619) 442-5864 * $562 f * K*Z o T Jr ^3£9) ^ 2^3/4^.^* f- fan- A7 57 . f* (/ft? .„ Structural Consultant (619)442-5864 \ / r) L+J£ (& d Si^i/ tifftt //n Kenneth H. Barrett , . CIVIL ENGINEER, CE-14659 > 'L' P. O. Box 12695 El Cajon, CA 92022 a. / 07*- . ZZj-td v PL If Structural Consultant nit- . * )<fl Kenneth H. Barrett CIVIL ENGINEER, CE-14659 P. 0. Box 12695 El Cajon, CA 92022 /S-32J 5 (619)442-5864 , _ „ c b'$'<77 (f) ///t/fr (fj J t •i 25 in*. 4-* fr~ / 1 u- 7/3 " Structural Consultant Kenneth H. Barrett CIVIL ENGINEER, CE-14659 P. 0. Box 12695 El Cajon, CA 92022 (619) 442-5864 3) »' y ' V til 04-' MO 4- ^* Structural Consultant ( 104-1 HSf Kenneth H. Barrett CIVIL ENGINEER, CE- 14659 P. 0. Box 12695 El Cajon, CA 92022 (619)442-5864 f * 4*1 2'6 35 •3-39 5) 1)02/4--27^ 0 ' yf* 40/Wf <?/«-Ci /Q<l Structural Consultant A /* - h; fr^y - - A; Kenneth H. Barren CIVIL ENGINEER, CE-14659 P. O. Box 12695 El Cajon, CA 92022 (619) 442-5864 lo /fl5 ,-l*)2A 3 • A''3 « /US/" S'y./'.«/g - ,d;, >A/ */ 6 4 3 s: ^ Structural Consultant ALL SCHEDULE 3/8" PLY, CDX 24/0, ^blocked all edges, 8d common nails, 12" o/c field nailing. - 6" edge nailing — 4" " 3\- 3" " " . 4\- 2" " " ., w/ 3x4 studs at adjoining panel edges... Studs @ 16" o/c 260# / Lt 380# / l.f. 490# / l.f. 640# / If. Studs @ 24" o/c 220# / l.f. 320# / l.f. 410# / l.f. 530# / l.f. 3/8" PLY, STRUCT I, 24/0, blocked all edges 8d common, nails, 12" o/c field nailing. 5\- 4" edge nailing. '6\- 3" " 7\- 2" " 430# / If. 550# / l.f. 730# / l.f. 360# / l.f. 460# / l.f. 610# / l.f. 15/32" PLY, STRUCT I1((24/0, blocked all edges lOd common nails, 12" o/c field nailing. 8\- 2" edge nailing ANCHOR BOLTS 2" plates 3" plates 4" plates 1/2" x 10" 5/8" x 10" 3/4" x 10" 5/8" x 12" 3/4" x 12" 5/8" x 12" 3/4" x 12" Perpendicular to grain 300# 360# 420# 460# 590# 700# 870# 870# / l.f. Parallel to grain 640# 640# 960# 1343# 1609# 1490# SHEAR TRANSFER PLATES ( S.T.P. ) PANEL UPLIFT TIE Model No. A35 A35F LTP4 Type of Construction s HI ID Direction of Uiad Fl F2 G J . H G J H Allowable Loads Floor (100) 450 515 500 265 440 515 515 515 Root (125) 450 645 500 265 440 645 645 645 LTP4 A35F A35 LTP4 INSTALLED OVER PLYWOOD SHEATHING. —i TYPICAL A35F INSTALLATION A35 TYPICAL CS INSTALLATION AS FLOOR-TO- FLOOR TIE (CMST REQUIRES MINIMUM 2-2x STUDS) CS16 ON 2x_ MST ON 4x_ (or DBL. 2x_) 1. Allowable loads are for one anchor When anchors are installed on each side of the joist, the minimum joist thickness is 3 inches. 2. Roof loads are 135% of floor loads unless limited by other criteria. Floor loads may be adjusted for other load durations according to the code, provided they do not exceed those in the roof column. 3. Some illistrations show connections that could cause cross-grain tension or bending of the wood during loading if not reinforced sufficeatly In this case, mechanical reinforcement should be considered. 4. G direction only : A35I and LTP4 can be installed over 3/B" plywood with Bd x 1 1/2" nails and achieve .72% of the listed load, or over 1/2" and achieve .64% of the listed load, 8d commons will achieve 100% load ICBO # 5279 Allowable Tension and Shear Loads for Threaded Rod Anchors Sh4 . On (W »4 '-4 '* v. % 1 Drill B*DU W '4 H V, '4 1 iVk Ulnlnum Embrt.Dtpth W IV, 3Vb 2% 4V. afc 5 3»A 6V« 3'A 7V* 4'A 9 Spuing (In.) 6% 6'*7Vfc 7Vi 6V4 BV4 12 12 13^ 13V. 1SV4 15V, £dgtout <*>4 S'/4 5'A 6* B*7'4 7'.* 10Vfc 1014 MS 11 S 1314 13'4 Avg Tarn ton Load fceMM P»l 1900 10200 7216 17700 6780 26720 15456 42100 19112 49160 20076 60060 AUombtt) TMuton Load! (KM) BUM] on Bond Strength r(*2MOp*l 475 2550 1605 4425 1695 66BO 3665 10525 47BO 12290 5020 15015 t'c>400aptl 475 2570 1805 4600 1695 8050 3865 10620 47 bO 13720 5020 16255 Bu«lon ' " SlMl Strength AM7 (SA£101I) 2105 2105 3750 3750 5875 5875 6460 6460 11500 11500 15025 15025 A193CRB7 (SAE414Q) 4535 4535 8080 aoao 12660 12660 18230 18230 24785 24785 32380 32380 FiSJ (A3045S) 30AS 3005 5495 5495 8610 8610 14585 14585 19630 19830 29905 29905 AUowtbtoShMrLMdi(U») BmdonSiMlSlnogttir^awop.1 A»r SAE 1011) —108S —1930 —3025 —4360 — 5925 —7740 A1i3 GR 87 (SAE 41 40) _ 2340 —4160_ 6520 — 9400 — 12770 — 16680 F5«3 (A3MSS)_ 1590 —2830 — 4435 —7515_ 10215 — 13345 Allowable Tension and Shear Loads for ASTM A615 Grade 40 and 60 Rebar DOM) Sat (to\ •4 15 • 6 •7~^ IB Drill Bit Oil W S v» '*1 IVfc Uinlmuffl EmbML topth (to.) 4V4 5 6»/4 7V. 9 Spicing W 7'4 av* 12 13*A 15V, EdBiout CM 6H 7'^ 10% 11»A 13 '4 Avg, UO TtuUn LMdrc»2(wp*l 16480 24600 38360 47760 60600 AUowaMi.TffntlMi LMdi (IU) Bw*i on Bond Strength r(.!w»p«i 4120 6150 9595 11940 15150 f(.4«»p«l 4580 6510 10125 11940 15150 AllMMbfeTmloflMdstMUlM^BucdonSlMl Strength (Ito) ASTUMISGnfeW ft i!OMp»l 4000 6200 8800 12000 15800 Altowtbta Tmikm «nd ShMfLtMitrBwMlon StMlSlnngth(IU) ASTUAfilSGftcttiar(22wgp.i 4800 7440 10560 14400 18960 Bolts in Concrete Masonry Units studOl«<mo Drill Dl« (in.) Mln. Embed. (In.) Edge Distance (In.) End Dieunot (In.) Allowable Lo»de '•* Ob») Tenalon Shoar Grout tilled CMU— Anchor !n»UII*d through tec* *h«ll V.V4 5 4 4V. Allowable Short Term Load (133) 1940 2585 2460 3280 Grout tilled CMU— Anchor instated In call opening V.V4 1 5 3 3^ Allowable Short Term Load (133) 3140 4185 2360 3175 Hollow CMU— Anchor InsUllwJ through vlnghi l»c» «h«ll Screen Tube required V.'4 5 4 4% Mttwabia Short Term Load {133) 220 295 675 900 1. Valim lor 6" and 8" wido Gradi N. TyiM II, UflWwstflM, nwdium or normal weight CMU accoiding to ASTM CM and UBC stambrd 2H. Gnxitad units lulty groutad with coursi Qfout conlonnlng to ASTM C476 wttn a minimum tompnsslirt st/mgtli ol 2000 psi. 2. EmbMtmtM Aeplh i» maasuied Irom U» outsida ol the block law Allowable Tension Loads (or Threaded Rod In Concrete Foundation Stemwall Comer Installation stud Dla. V. % Drill Bit Dla. v« 1 Mia Embed. D*pu\ 10 15 Mln. Wall Thtekneaa 6 8 Mln. Edge Dl*L 1V4 1V4 Uln. EndDiM. 5 5 Altowabl*Tenalon Load* f'c«2000p«l 5750 8400 , Allowable Short Term Tenaton toad !'• -2000 paJ 7665 11200 bctor ol 4) or steel sttwgti •xcaedlll'F. tw oblakw) by Bow JntarpcUtkn. 4. rx earthquake, jxwcted tw ahaw toads do not 6K»ed ha 5ieals(rBnBihl«ASTMA307»¥«adfl(lrrjd. 5. Altowafite bad bawd on bond, areogih may be Jnl0rpoUledlorconcfflleco(npressiv«strengihs twhwen 2000 psi and 4000 psL 6. Shear MMcitv lor rf^ftf « bnitAd 10 rho afiowablft *l»p| Mrwvrltv Edge and end dlstanca* for thraadad rod In concrete foundation ttamwall corner Inatallatlon Kenneth H. Barrett CIVIL ENGINEER, CE-14659 P. 0. Box 12695 El Cajon, CA 92022 (619) 442-5864 *- 5-5? 7-5V*/ 33 -* tot * '- ft A/ *&) <^- 7/^ / ~r -/ CCS y> r i. * 7 ^- J .£6 "c" ,1 s/ /-? (— / 'L 36.} I Structural Consultant * Ct '=• 3; Z>^= ="=•? S I" » ?iils I *"IH-|^ = I li If lifa-l5?i«>? = i^l 1.2 i ^ = ~i-~l flr^l! >i §> — £ c s E"*: IT E - — :>S B ^ -5 s' - —<!'> S-S 1-1 — ^ ^ = i2 £ ••* c-"1 ^. si«!is.|§'il 7 - =• ? a- S = §.*.' ' ? C s £. S S R' £ BJ B H Hn o n n r a rH- B H-< » <o o. a 13 13 1Jtt 0) 01 a 13 •8 •? 9» M» O'O H- W• 9 Ho IQ n. n • 1C O Z a 5 V = CS — B tJ M'LQB) fU Wrr . •<« —0)D - ITnWT3 30 n(t D H-t)T! l-rt->0 H-p ED 0 IT n top-D.0 U= 13 1nan110ill U OIII OH-lfl03 5 (U o rr to noH-S^ 3 •a i- MOBSU = (T — (D *-• WUJ °"1, i-hU 0 ai» ta ••*. •w^ -jioLj-jo . .,1 A1 ' '& ^53??T^ p5| .' "Sn t--jU 10 i —«x»-oi?\r — OKJO-^O. H- W~t 3^j -j \& Q to H. PO M •& O 1> S»J tf=] B£So voM n't-1 WWi-'M itkUJ' cowl •^WSui on nwioM PM WCOM "fMQ W)-'HSJ| ~ KSStr!\D LH i/i M> | oUi£(i £000!UlUiSf !&. wit w-Ju>-O>-i m o &%-KR *-* H*x* o i*i M nl/H/il^ U1U W Ln infopOR !??? 7 2 = 935UtffUIss^iiMi-X 5 ± ~ fi-o 1C - 21 z'fTS fliill'ill!"'"' Hi' B"9^ssO3s1^*55iT:='?'2. 5s * 5 o i- o r- Ot <' 01 <O. (* O. 4 o *• ^ b b b b •a -a TJ TJU> Ul UI (ff n c-o -i -o — co<» 3 3n to a. 8 « 8 isa i£^ '2gS H O3 O 2n ^oK)00 <M "Qn) C = «CD iH H 0, 0 UA(0 t! ID jj 0at i*jivon •H ftCDC •o ao ITJ nj £N ^•oI) HI (Ifc acn o TJ-H tO W-U V C4-1 O M ffl-H 0<H AJ aP--HUJEQ OE O.1 at— v>, • jjman H = 3 M o £a » CU ft ft 0, > a p UH B £ | 1 •= i I y * 3 S ? plT^J yiiJ^- tJ = 'I = 2 g e .a " .' T C8a|||'£«hSst' E_= T; C 8*S^E:til s^| &| = S? &•< g, g ^ B a ^::".. x^1 i^< -5 = -° .sip y o » ^ .;? - •=•-rfS^-gS-Sn-^Shi.a ialilllSPIl UJ a: UJea i = 2. COAST GEOTECHNICAL CONSULTING ENGINEERS AND GEOLOGISTS August 23, 1999 Kelly Courson 2815 Elmwood Street Carlsbad, CA 92008 Subject: LIMITED GEOTECHNICAL INVESTIGATION Proposed Residential Additions 2815 Elmwood Street Carlsbad, California Dear Ms. Courson: In response to your request and in accordance with our Proposal and Agreement dated June 10, 1999, we have performed a preliminary geotechnical investigation on the subject site for the proposed additions. The findings of the investigation, laboratory test results and recommendations for foundation design are presented in this report. From a geotechnical point of view, it is our opinion that the site is suitable for the proposed development, provided the recommendations in this report are implemented during the design and construction phases. If you have any questions, please do not hesitate to contact us at (858) 755-8622. This opportunity to be of service is appreciated. Respectfully submitte COAST GEOTECHNI Mark Burwell, C.E.G. Engineering Geologist Vithaya Singhanet, P Geotechnical Engineer 779 ACADEMY DRIVE • SOLANA BEACH • CALIFORNIA 92075 (619) 755-8622 • FAX (619) 755-9126 LIMITED GEOTECHNICAL INVESTIGATION Proposed Residential Additions 2815 Elmwood Street Carlsbad, California Prepared For: Kelly Courson 2815 Elmwood Street Carlsbad, CA 92008 August 23, 1999 W.O. P-300069 Prepared By: COAST GEOTECHNICAL 779 Academy Drive Solana Beach, California 92075 TABLE OF CONTENTS VICINITY MAP INTRODUCTION 5 SITE CONDITIONS 5 PROPOSED DEVELOPMENT 6 SITE INVESTIGATION 6 LABORATORY TESTING 6 GEOTECHNICAL CONDITIONS 7 CONCLUSIONS 11 RECOMMENDATIONS 12 A. GENERAL 12 B. FOUNDATIONS 12 C. SLABS ON GRADE (INTERIOR AND EXTERIOR) 13 D. SETTLEMENT CHARACTERISTICS 14 E. SEISMIC CONSIDERATIONS 14 F. RETAINING WALLS 15 G. DRAINAGE 15 H. UTILITY TRENCH 16 I. GEOTECHNICAL OBSERVATIONS 16 J. PLAN REVIEW 17 LIMITATIONS 17 REFERENCES 19 APPENDICES APPENDIX A LABORATORY TEST RESULTS BORING LOGS TEST PIT LOGS SITE PLAN APPENDIX B REGIONAL FAULT MAP EARTHQUAKE FAULT ANALYSIS COAST GEOTECHNICAL P-300069 VICINITY MAP SCALE: 1:8,000 Coast Geotechnical August 23, 1999 W.O. P-300069 Page 5 INTRODUCTION This report presents the results of our geotechnical engineering investigation on the subject property. The purpose of this study is to evaluate the nature and characteristics of the surficial deposits underlying the property and their influence on the construction of the proposed residential additions. SITE CONDITIONS The subject property is located south of Buena Vista Way, along the west side of Elmwood Street, in the city of Carlsbad. The site includes a single-family residence and a detached garage situated on a rectangular lot. The property descends to the west at a gentle grade of approximately 4.0 to 5-0 percent, however, the placement of minor fill has resulted in a relatively level front yard area. The existing residential structure is supported on stem wall footings with raised wood floors. A previous addition along the northwest portion of the structure is supported on continuous wall footings with a slab on grade floor. Vegetation consists of residential landscaping including grass, plants and trees. An asphaltic concrete driveway is located along the southeastern portion of the lot and a concrete slab is present along the northern residential foundation. Roof drainage is partially collected along the front of the residence by a gutter. However, most of the site drainage is generally directed to the west. Coast Geotechnical August 23, 1999 W.O. P-3O0069 Page 6 PROPOSED DEVELOPMENT Preliminary plans for the additions were prepared by Plato Carpadakis, Designer. The project includes a second-story addition over the residence, small single-story additions along the front (eastern) and northern sides of the residence, and a new garage in the southeastern portion of the lot. SITE INVESTIGATION Two 3.5 inch diameter exploratory borings (B-l and B-2) were drilled on the site to a maximum depth of 9-0 feet. Two borings B-1A and B-2A encountered asphaltic concrete at shallow depths of 0.5 feet and 1.0 feet, respectively. Two test pits were excavated adjacent to the foundation to evaluate footing embedment and the characteristics of the supporting soils. Earth materials encountered were visually classified and logged by our field geologist. Relatively undisturbed and bulk samples of earth materials were obtained at selected intervals. Samples were obtained by driving a thin walled steel sampler into the desired strata, where possible. The samples are retained in brass rings of 2.5 inches outside diameter and 1.0 inches in height. The central portion of the sample is retained in close fitting, waterproof containers and transported to our laboratory for testing and analysis. LABORATORY TESTING Classification The field classification was verified through laboratory examination, in accordance with Coast Geotechnical August 23, 1999 W.O. P-300069 Page 7 the Unified Soil Classification System. The final classification is shown on the enclosed Exploratory Logs. Moisture/Density The field moisture content and dry unit weight were determined for each of the undisturbed soil samples. This information is useful in providing a gross picture of the soil consistency or variation among exploratory excavations. The dry unit weight was determined in pounds per cubic foot. The field moisture content was determined as a percentage of the dry unit weight. Both are shown on the enclosed Appendix "A". Maximum Dry Density/Optimum Moisture Content The maximum dry density and optimum moisture content were determined for selected samples of earth materials taken from the site. The laboratory standard tests were in accordance with ASTM D-1557-91. The results of the tests are presented in Appendix "A". GEOTECHNICAL CONDITIONS The subject property is underlain at relatively shallow depths by Pleistocene terrace deposits. The terrace deposits are underlain at depth by Eocene-age sedimentary rocks which have commonly been designated as the Santiago Formation on published geologic maps. The terrace deposits are overlain, in part, by locally derived fill material and soil. A brief description of the earth materials encountered on the site is discussed below. Coast Geotechnical August 23, 1999 W.O. P-300O69 Page 8 Artificial Fill/Soil OJndifferentiated) Based on Boring No. 1 and Test Pit No. 1, approximately 2.0 to 2.5 feet of fill/soil is present in the front yard area of the residential structure. It should be noted that approximately 0.5 to 1.0 feet of fill is present over asphaltic concrete in the vicinity of Boring Nos. 1A and 2A. The fill is generally composed of silty and fine-grained sand in a loose condition. In the vicinity of Test Pit No. 2 (rear yard area), approximately 0.5 feet of brown silty sand was encountered. The soil appears to thicken to the west to approximately 1.25 feet in the vicinity of Boring No. 2. Terrace Deposits Underlying the surficial materials, Pleistocene-age terrace deposits are present. The sedimentary unit is composed of dry tan sand in the upper 1.0 foot but grades to reddish brown, fine and medium-grained, slightly clayey sand with depth. The terrace deposits are dense and generally considered flat-lying. Expansive Soil Based on our experience in. the area and previous laboratory testing of selected samples, the fill materials and terrace deposits reflect an expansion potential in the low range. Coast Geotechnical August 23, 1999 W.O. P-300069 Page 9 Existing Footings Two test pits were excavated along the east (front) and west (rear) sides of the exterior stem wall foundation The base of the eastern wall footing is founded approximately 21 inches below the exterior grade. The base of the western wall footing is founded approximately 6.0 inches, below the exterior grade. The base of the footings, where observed, penetrate the surficial deposits but are resting along the top of the terrace deposits contact. Ground Water No evidence of high ground water conditions were observed. However, perched water conditions can develop in the front yard area adjacent to the foundation due to pervious fill materials underlain by dense terrace deposits. These seepage problems most often result from drainage alterations, landscaping and over-irrigation. In the event that seepage or saturated ground does occur, it has been our experience that they are most effectively handled on an individual basis. Tectonic Setting The site is located within the seismically active southern California region which is generally characterized by northwest trending Quaternary-age fault zones. Several of these fault zones and fault segments are classified as active by the California Division of Mines and Geology (Alquist-Priolo Earthquake Fault Zoning Act). Coast Geotechnical August 23, 1999 W.O. P-30O069 Page 10 Based on a review of published geologic maps, no known faults transverse the site. A steeply dipping short fault segment has been mapped approximately */2 mile northeast of the site. This northeast trending fault is exposed in the Eocene-age rocks of the Santiago Formation but not in the overlying Pleistocene terrace deposits and is presumably inactive. The nearest active fault is the offshore Rose Canyon Fault Zone located approximately 5.0 miles west of the site. It should be noted that the Rose Canyon Fault is not a continuous, well-defined feature but rather a zone of right stepping en echelon faults. The complex series of faults has been referred to as the Offshore Zone of Deformation (Woodward- Clyde, 1979) and is not fully understood. Several studies suggest that the Newport- Inglewood and the Rose Canyon faults are a continuous zone of en echelon faults (Treiman, 1984). Further studies along the complex offshore zone of faulting may indicate a potentially greater seismic risk than current data suggests. Other faults which could affect the site include the Coronado Bank, Elsinore, San Jacinto and San Andreas Faults. The proximity of major faults to the site and site parameters are shown on the enclosed Earthquake Fault Analysis. Liquefaction Potential Liquefaction is a process by which a sand mass loses its shearing strength completely and flows. The temporary transformation of the material into a fluid mass is often associated with ground motion resulting from an earthquake. Coast Geotechnical August 23, 1999 W.O. P-300069 Page 11 Owing to the moderately dense to dense nature of the underlying sedimentary deposits and the anticipated depth to ground water, the potential for seismically induced liquefaction and soil instability is considered low. CONCLUSIONS 1) From a geotechnical viewpoint the exterior footing, where exposed, is not suitable for the support of additional loads. Where increases in loading due to the second story addition occur, the existing footing should be underpinned with a new continuous wall footing or new loads transferred to column pads as recommended by the project structural engineer. 2) Interior footing embedment is not known and should be evaluated during the construction phase where additional loads are anticipated. 3) All new footings should be founded the designed depth into the underlying competent terrace deposits. 4) Existing fill and soil deposits should be removed and replaced as compacted fill in areas of proposed slabs on grade. Additional recommendations may be necessary during construction, in this regard. Coast Geotechnical August 23, 1999 W.O. P-300069 Page 12 RECOMMENDATIONS General Site exploration suggests that the perimeter continuous stem wall footing is founded approximately 6.0 inches to 21 inches below grade along the exterior foundation line. However, the base of the footings are resting along the top of the terrace deposits. From a geotechnical viewpoint, the embedment depth is not adequate to support a second story addition or additional loads. Interior footing embedment is not known and should be evaluated during the construction phase if additional loads are anticipated. Where fill deposits are encountered, additional depth of footing excavations will be required. Additional recommendations will be provided during construction, in this regard. Foundations The following parameters may be used in the design of new foundations and underpins, New underpinned footings or column pads for the proposed two-story addition should be founded a minimum of 18 inches below the existing footing and into competent terrace deposits. All proposed residential footings should extend a minimum of 18 inches into competent terrace deposits for single or two-story additions. New continuous footings designed as underpins may be constructed in alternate sections. However, undermining of the existing footing should not exceed 4.0 to 5.0 lateral feet as recommended by the project structural engineer for each alternate underpinned section Coast Geotechnical August 23, 1999 W.O. P-300069 Page 13 constructed. If the existing footing is undermined for greater than 5.0 lateral feet, the existing footing should be shored or supported as recommended by the project structural engineer. Footings founded into competent terrace deposits, as recommended above, may be designed for a bearing value of 1500 pounds per square foot. Footings should be reinforced with steel as recommended by the project structural engineer. The bearing value indicated above is for the total dead and frequently applied live loads. This value may be increased by 33 percent for short durations of loading, including the effects of wind and seismic forces. Resistance to lateral load may be provided by friction acting at the base of foundations and by passive earth pressure. A coefficient of friction of 0.35 may be used with dead- load forces. A passive earth pressure of 250 pounds per square foot, per foot of depth of terrace deposits penetrated to a maximum of 1500 pounds may be used. Slabs on Grade (Interior and Exterior^ Slabs on grade should be a minimum of 4.0 inches thick and reinforced in both directions with No. 3 bars placed 18 inches on center in both directions. The slab should be underlain by a minimum 2.0-inch sand blanket. Where moisture sensitive floors are used, a minimum 6.0-mil Visqueen or equivalent moisture barrier should be placed over Coast Geotechnical August 23, 1999 W.O. P-300069 Page 14 the sand blanket and covered by an additional two inches of sand. Slabs including exterior concrete flatwork should be reinforced as indicated above and provided with saw cuts/expansion joints, as recommended by the project structural engineer. All slabs should be cast over dense compacted subgrades. Settlement Characteristics Settlement of footings founded into competent terrace deposits, as recommended, is expected to be minimal. However, as existing footings are repositioned on new footings, due to imposed loads, some degree of stucco cracking may occur. This is not foundation settlement, but rather adjustment of existing footings onto new footings. Total and differential settlement is expected to be on the order of 1/4 inch and 1/4 inch, respectively. It should also be noted that long term secondary settlement due to irrigation and loads imposed by structures is anticipated to be 1/4 inch. Seismic Considerations Although the likelihood of ground rupture on the site is remote, the property will be exposed to moderate to high levels of ground motion resulting from the release of energy should an earthquake occur along the numerous known and unknown faults in the region. Coast Geotechnical August 23, 1999 W.O. P-300069 Page 15 The Rose Canyon/Newport-Inglewood Fault Zone, as previously described, is the nearest known active fault complex and is considered the design earthquake for the site. A maximum probable event along the offshore segment of the Rose Canyon/Newport- Inglewood Fault is expected to produce a peak bedrock horizontal acceleration of 0.35g and a repeatable ground acceleration of 0.23g- Retaining Walls Cantilever walls (yielding) retaining nonexpansive granular soils may be designed for an active-equivalent fluid pressure of 35 pounds per cubic foot. Restrained walls (nonyielding) should be designed for an "at-rest" equivalent fluid pressure of 58 pounds per cubic foot. Wall footings should be designed in accordance with the foundation design recommendations. All retaining walls should be provided with an adequate back drainage system. It is suggested that prefabricated drainage composites such as Miradrain 6000 be considered for this project. The soil parameters assume a granular non- expansive backfill compacted to a minimum of 90 percent of the laboratory maximum dry density. Drainage Specific drainage patterns should be recommended by the project designer. However, in general, pad water should be directed away from foundations and around the structure to the street. Roof water should be collected and conducted to the street or suitable Coast Geotechnical August 23, 1999 W.O. P-300069 Page 16 discharge location, via non-erodible devices. Pad water should not be allowed to pond. Vegetation adjacent to foundations should be avoided. If vegetation in these areas is desired, sealed planter boxes or drought resistant plants should be considered. Other alternatives may be available, however, the intent is to reduce moisture from migrating into foundation subsoils. Irrigation should be limited to that amount necessary to sustain plant life. All drainage systems should be inspected and cleaned annually, prior to winter rains. Utility Trench We recommend that all utilities be bedded in clean sand to at least one foot above the top of the conduit. The bedding should be flooded in place to fill all the voids around the conduit. Imported or on-site granular material compacted to at least 90 percent relative compaction may be utilized for backfill above the bedding. The invert of subsurface utility excavations paralleling footings should be located above the zone of influence of these adjacent footings. This zone of influence is defined as the area below a 45 degree plane projected down from the nearest bottom edge of an adjacent footing. This can be accomplished by either deepening the footing, raising the invert elevation of the utility, or moving the utility or the footing away from one another. Geotechnical Observations Structural footing excavations should be observed by a representative of this firm, prior Coast Geotechnical August 23, 1999 W.O. P-300069 Page 17 to the placement of steel or forms. Additional depth may be required. All remedial grading should be observed and tested by a representative of the geotechnical engineer. Plan Review A copy of the final plans should be submitted to this office for review prior to the initiation of construction. Additional recommendations may be necessary at that time. LIMITATIONS This report is presented with the provision that it is the responsibility of the owner or the owner's representative to bring the information and recommendations given herein to the attention of the project's architects and/or engineers so that they may be incorporated into plans. If conditions encountered during construction appear to differ from those described in this report, our office should be notified so that we may consider whether modifications are needed. No responsibility for construction compliance with design concepts, specifications or recommendations given in this report is assumed unless on-site review is performed during the course of construction. The subsurface conditions, excavation characteristics and geologic structure described herein are based on individual exploratory excavations made on the subject property. The subsurface conditions, excavation characteristics and geologic structure discussed Coast Geotechnical August 23, 1999 W.O. P-300069 Page 18 should in no way be construed to reflect any variations which may occur among the exploratory excavations. Please note that fluctuations in the level of ground water may occur due to variations in rainfall, temperature and other factors not evident at the time measurements were made and reported herein. Coast Geotechnical assumes no responsibility for variations which may occur across the site. The conclusions and recommendations of this report apply as of the current date. In time, however, changes can occur on a property whether caused by acts of man or nature on this or adjoining properties. Additionally, changes in professional standards may be brought about by legislation or the expansion of knowledge. Consequently, the conclusions and recommendations of this report may be rendered wholly or partially invalid by events beyond our control. This report is therefore subject to review and should not be relied upon after the passage of two years. The professional judgments presented herein are founded partly on our assessment of the technical data gathered, partly on our understanding of the proposed construction and partly on our general experience in the geotechnical field. Our engineering work and the judgments given meet present professional standards. However, in no respect do we guarantee the outcome of the project. Coast Geotechnical August 23, 1999 W.O. P-3O0069 Page 19 REFERENCES 1. Coast Geotechnical, 1997, Preliminary Geotechnical Investigation, Two Continuous Vacant Lots, Terminus of Cynthia Lane, Carlsbad, California. 2. Hays, Walter W., 1980, Procedures for Estimating Earthquake Ground Motions, Geological Survey Professional Paper 1114, 77 pages. 3- Seed, H.B., and Idriss, I.M., 1970, A Simplified Procedure for Evaluating Soil Liquefaction Potential: Earthquake Engineering Research Center. 4. Treiman, J.A, 1984, The Rose Canyon Fault Zone, A Review and Analysis, California Division of Mines and Geology. 5. Weber, F,H. Jr., 1983, Recent Slope Failures, Ancient Landslides and Related Geology of the North-Central Coastal Area, San Diego County, California: California Division of Mines and Geology, Open-File Report 82-12IA. MAPS/AERIAL PHOTOGRAPHS 1. Aerial Photograph, 1982, Foto-Map D-7, Scale 1"=2000'. 2. California Division of Mines and Geology, 1994, Fault Activity Map of California, Scale 1"=750,000'. 3. Carpadakis, P., 1999, Site Plan, 2nd Story Addition for Kelly Courson and Thomas Gonsalez, Scale: 1"=20'. 4. Geologic Map of the Oceanside, San Luis Rey and San Marcos 7.5' Quadrangles, 1996, DMG Open File Report 96-02. APPENDIX A LABORATORY TEST RESULTS TABLE I Maximum Dry Density and Optimum Moisture Content (Laboratory Standard ASTM D-1557-91) Sample Location B-l 1' -4 Max. Dry Density (pcf) 128.2 Opt imum Moisture Content 10.6 TABLE II Field Dry Density and Moisture Content Sample Location B-l B-l B-l B-l 1.2 2.5 5.0 7.0 B-2 @ 2.51 B-2 @ 3.5' B-2 @ 5.0' B-2 @ 8.5' TP-1 @ 1.75' TP-2 @ 0.5' Field Dry Density (pcf) 90.2 114.2 115.1 116.8 114.8 113.1 115.2 Sample Disturbed 104.4 108.2 Field Moisture Content (%) 4.3 3.4 4.5 6.9 4 .8 5.1 8.1 8.4 3.9 3.8 P-300069 LOG OF EXPLORATORY BORING NO. 1 DRILL RIG: PORTABLE BUCKET AUGER PROJECT NO. P-300069 BORING DIAMETER: 3.5" DATE DRILLED: 07-22-99 SURFACE ELEV.: 146' LOGGED BY: MB DRY DENSITY (pcf)90.2 114.2 115.1 116.8 g OO 1 4.3 3.4 4.5 6.9 SUBSURFACE WATERNO GROUND WATER OBSERVEDSAMPLE1 1 DEPTH /ELEVATION*•ONS0.00 — 145.00 — 1.00 — 144.00 — 2.00 — 143.00 — 3.00 — 142.00 — 4.00 — 141.00 — 5.00 — 140.00 — 6.00 — 139.00 — 7.00 '— 138.00 8.00 — 137.00 GRAPHIC LOG!S* ,ii .ii &KOTM IS1 Iffl l« I $1 H inHI S ffl Nm (11fflmiti HPHi"VIiIi $w Si18 9.00 PAGE 1 OF 1 ]j| im'Sl!BJfflSSiiiW i i!W( I HIM Svtfmmw UNvwv1m If I WTO ™tffiKutnraimnS5;•;•;«a«iWH Peowp™y mil uSun Bw KSi K?<nw SOIL CLASS. (USCS)SM SM GEOLOGIC DESCRIPTION FILL/SOIL, Undifferentiated (af/Qs): Brn. silty sand, dry, loose, cone, debris, roots TERRACE DEPOSITS (Qt): Tan, silty, fine and med. -grained sand, dry, dense From 3.5', Reddish brn. fine and med. -grained sand, slightly clayey END OF BORING @9' COAST GEOTECHNICAL LOG OF EXPLORATORY BORING NO. 2 DRILL RIG: PORTABLE BUCKET AUGER PROJECT NO. P-300069 BORING DIAMETER: 3.5" DATE DRILLED: 07-22-99 SURFACE ELEV.: 143' (approx.) LOGGED BY: MB DRY DENSITY (pcf)114.8 113.1 115.2 2 ou 4.8 5.1 8.1 8.4 SUBSURFACE WATERNO GROUND WATER OBSERVEDSAMPLE1 1 DEPTH /ELEVATION«<*)S— 0.00 142.00 - — 1.00 = 141.00 , 2.00 P^ 140.00 — 3.00 — 139.00 4.00 — 138.00 __ 5.00 = 137.00 — 6.00 = 136.00 — 7.00 = 135.00 — 8.00 — 134.00 GRAPHIC LOG:H=I ijjiijj njjrjj UwTVUIwWuu<iiVH ul3 ii %™isiSI w1nIM S H( 1iiiCfiimiasw ftiKi ™ 1fflAftISwSHiUlpapi; in 9.00 PAGE 1 OF 1 MMmanHMfPHHttlAlO ESinuii«XB 1 1 I i I ™ imm iliplffi iam wituunmEIIHDSBBmWffSmnunMU hnnn 1m mMU Pivnvm»^S1HW P ftffiDfflMBuywi 1HS 1 1ISL'J! lii SOIL CLASS. (USCS)SM SM GEOLOGIC DESCRIPTION SOIL (Qs): Bra. silty sand, dry, loose, roots TERRACE DEPOSITS (Qt): Tan, silty, fine and med.-grained sand, dry, dense From 2.5', Reddish brn. fine and med.-grained sand, slightly clayey END OF BORING® 9' COAST GEOTECHNICAL LOG OF TEST PIT NO. 1 DRY DENSITY (pcf)104.4 £MOISTURE CONTENT3.9 SUBSURFACE WATERSAMPLE•g DEPTH /ELEVATION80.00 145.00 1.00 — 144.00 2.00 GRAPHIC LOG!!=!!=!•SI 9f fft *|!==!i=r i: sc :i: • MftBHOBttX SOIL CLASS. (USCS)SM SM PROJECT NO. P-300069 DATE EXCAVATED\ 07-22-99 SURFACE ELEV.: 146'(approx.) LOGGED BY: MB DESCRIPTION FILL/SOIL, Undifferentiated (af/Qs): Brn. silty sand, dry, loose, cone. debris, roots TERRACE DEPOSITS (Qt): Tan, silty, fine and med-grained sand, dry, dense TEST PIT SKETCH i1 l . *»• \ •'- ' I. / f'v " I . . /1 11 1 \. / SHEET 1 OF 1 COAST GEOTECHNICAL LOG OF TEST PIT NO. 2 Q I Ou 1 Iw a 1 144.00 O & c/i CJ PROJECT NO. P-300069 DATE EXCAVATED: 07-22-99 SURFACE ELEV.: 144'(approx.) LOGGED BY: MB DESCRIPTION 108.2 3.8 0,00 SM SOIL (Qs): Brn. silty sand, dry, loose, roots SM TERRACE DEPOSITS (Qt): Tan, silty, fine and med.-grained sand, dry, dense 143.00 1.00 142.00 2,00 TEST PIT SKETCH ' * / ? '-/— \Qt / SHEET I OF I COAST GEOTECHNICAL LEGEND BORING LOCATION (approi.) BJ TEST PIT LOCATION (approx.)COAST GEOTECHNICAL P-300069 SITE PLAN SCALE: 1"=20' APPENDIX B - DATE: Thursday, August 19, 1999 ************************************* * * * EQFAULT * * * * Ver. 2.20 * * * * * ************************************* (Estimation of Peak Horizontal Acceleration From Digitized California Faults) SEARCH PERFORMED FOR: COURSON JOB NUMBER: P-300069 JOB NAME: P-300069 SITE COORDINATES: LATITUDE: 33.1682 N LONGITUDE: 117.3405 W SEARCH RADIUS: 60 mi ATTENUATION RELATION: 2) Campbell & Bozorgnia (1994) Horiz. - Soft Rock UNCERTAINTY (M=Mean, S=Mean+l-Sigma): S SCOND: 0 COMPUTE PEAK HORIZONTAL ACCELERATION FAULT-DATA FILE USED: CDMGSCE.DAT SOURCE OF DEPTH VALUES (A=Attenuation File, F=Fault Data File): A DETERMINISTIC SITE PARAMETERS Page ABBREVIATED FAULT NAME SAN JACINTO-COYOTE CREEK SAN JACINTO-ANZA SAN JACINTO-SAN JACINTO VA SAN JACINTO-SAN BERNARDINO ELSINORE-COYOTE MOUNTAIN ELSINORE-JULIAN ELSINORE-TEMECULA ELSINORE-GLEN IVY WHITTIER CHINO-CENTRAL AVE . (Elsino EARTHQUAKE VALLEY CORONADO BANK NEWPORT- INGLEWOOD (Offshor ROSE CANYON NEWPORT- INGLEWOOD (L.A.Bas PALOS VERDES COMPTON THRUST ELYS IAN PARK THRUST DISTANCE mi (km) 52 ( 84) 46 ( 74) 46 ( 75) 59 ( 94) 58 ( 94) 24 ( 38) 23 ( 38) 33 ( 53) 50 ( 81) 47 ( 76) 44 ( 71) 22 ( 35) 5 ( 8) 5 ( 9) 45 ( 73) 36 ( 57) 55 ( 88) 57 ( 92) MAX. C MAX. CRED. MAG. 6.80 7.20 6.90 6.70 6.80 7.10 6.80 6.80 6.80 6.70 6.50 7.40 6.90 6.90 6.90 7.10 6.80 6.70 :REDIBLI PEAK SITE ACC. g 0.048 0.083 0.063 0.037 0.041 0.177 0.146 0.095 0.051 0.051 0.048 0.240 0.622 0.610 0.065 0.109 0.065 0.056 3 EVENT SITE INTENS MM VI VII VI V V VIII VIII VII VI VI VI IX X X VI VII VI VI MAX. 1 MAX. PROB. MAG. 6.20 6.90 6.80 6.70 6.20 6.40 6.30 6.30 5.90 5.50 5.70 6.30 5.80 5.70 5.60 6.20 5.80 5.80 DROBABLI PEAK SITE ACC. g 0.028 0.064 0.057 0.037 0.024 0.106 0.099 0.062 0.023 0.020 0.023 0.112 0.346 0.308 0.020 0.050 0.029 0.027 3 EVENT SITE INTENS MM V VI VI V IV VII VII VI IV IV IV VII IX IX IV VI V V -END OF SEARCH- 18 FAULTS FOUND WITHIN THE SPECIFIED SEARCH RADIUS. THE NEWPORT-INGLEWOOD (Offshore) FAULT IS CLOSEST TO THE SITE. IT IS ABOUT 5.2 MILES AWAY. LARGEST MAXIMUM-CREDIBLE SITE ACCELERATION: 0.622 g LARGEST MAXIMUM-PROBABLE SITE ACCELERATION: 0.346 g !^lkW,i4 CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 1 CF-1R Date 05/05/99Project Title COURSON / GONSALEZ Project Address ELM WOOD STREET ******* CARLSBAD *v4.50* Documentation Author... ROCKY ******* Salehi & Salehi Inc. 9636 Tierra Grande Street, Ste 205 San Diego, CA 92126 619-549-3680 Climate Zone 07 Compliance Method MICROPAS4 v4.50 for 1995 Standards by Enercomp, Inc. Building Permit # Plan Check / Date Field Check/ Date MICROPAS4 v4.50 File-M506 Wth-CTZ07S92 Program-FORM CF-1R User#-MP0406 User-Salehi & Salehi Inc. Run-S.F.R. GENERAL INFORMATION Conditioned Floor Area Building Type Construction Type Building Front Orientation. Number of Dwelling Units... Number of Stories Floor Construction Type.... Glazing Percentage Average Glazing U-value.... 1754 sf Single Family Detached Addition Alone Front Facing 90 deg (E) .53 2 Raised Floor 20.5 % of floor area 1.1 Btu/hr-sf-F BUILDING SHELL INSULATION Component Frame Type Type Wall Wood Roof Wood FloorExt Wood Orientation Window Window Window Window Window Window Window Window Window Window Window Window Window Window Window Window Window Window Front Front Front Front Front Front Back Back Back Back Back Back Right Right Right Right Right Right (E) (E) (E) (E) (E) (E) (W) (W) (W) (W) (W) (W) (N) (N) (N) (N) (N) (N) Cavity Sheathing Insul Assembly R-value R-value R-value U-value Location/Comments R-13 R-0 R-13 0 R-30.75 R-0 R-30.75 0 R-30 R-0 R-30 0 FENESTRATION Area (sf) 13.3 46.5 15.0 8.1 12.0 24.5 16.0 40.0 8.2 17.5 6.1 24.0 5.7 12.0 20.0 8.2 9.0 4.5 u- Value 1. 1. 1. 1. 1. 1. 1. 1. 1. 1. 1. 1. 1. 1. 1. 1. 1. 1. 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 110 # of Interior Pan- Shadinq/ es 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Description Drapes Drapes Drapes Drapes Drapes Drapes Drapes Drapes Drapes Drapes Drapes Drapes Drapes Drapes Drapes Drapes Drapes Drapes .Std .Std .Std .Std .Std .Std .Std .Std .Std .Std .Std .Std .Std .Std .Std .Std .Std .Std .089 FRONT, LEFT .036 Attic .034 BACK, RIGHT Over- Exterior hang/ Framing Shading None None None None None None None None None None None None None None None None None None Fins Type Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Vinyl Vinyl Vinyl Vinyl Vinyl Vinyl Vinyl Vinyl Vinyl Vinyl Vinyl Vinyl Vinyl Vinyl Vinyl Vinyl Vinyl Vinyl ESGIL Fax:18585601576 Nov 4 '99 12=56 P.01 EsGil Corporation In Partners/ity n/ttfi government for {Bui&fing Safety FAX TRANSMITTAL Date:.92- / Time Sent; 12-1*55 To: Phone #: Fax#; Number of Pages Being Transmitted: O (Including Fax Transmittal) From:(.( Hard Copy Mailed? YES Q NO Remarks: 4\l' T c 9320 Chesapeake Drive, Sulie 208 * San Diego, California 92123'+ (858)560-1468 4- Fax (858) 560-1576 ESGIL Fax=18585601576 Nov 4 '99 12=56 P. 02 PLATO CARPADAKIS Memo to PlanchecKer.. Chuck Mendftttha.ll DESIGN CONSULTANT October 25 1999 Esgil Plancheck 8'99-2396 There ar« apparently some things you do not know about this project '. which are material to its progress and completion. The Soils Engineering firm (who I will never use or recommend again) was retained by. the Owner thinking that the soils work would affect the construction in a logical, beneficial and professional manner* What .the Owner ultimately got for her $2500 was a report containing what I believe to be some useless geological history, borings and excavations made in places where no new construction is proposed, and recommendations of such over-kill design that it will most likely cost the Owner thousands ,! of extra, dollars to implement them for no commensurate valid reasons. !l • '.; . EXAMPLE: On- the north side of the building the 12" wide continuous footing monolithically cast with a floor slab as recoramended by the soils report would, by.my estimate, weiah approximately 450 #/l.f,: all to support the exterior 8 ft high stud wall and 2% ft of light roof structure all weighing around 120 #/l.f. -or- less than one third of the proposed footing weight. If this is not over-kill, I don't know what else to call it. There are other glaring examples of his conservative recommendations which I brought to his attention in a phone call 2 months ago after receipt of this' report. I asked him to review some of these apparent discrepancies but he seemed un-interested in pursuing the matter or meeting with me. He was busy with other projects, and his report had been prepared, published, distributed and FULLY PAID FOR. He said that if the structural engineer on the project was satisfied with the foundation drawinas then he should accept liability for the project. As it happens, the engineer of record for this project is Mr. Kenneth ; Barrett, c.E. who has seen both the soils report and the plans. He also agreed with me that these recommendations are indeed a case of "overkill" and need not be implemented; especially for a residence which was built almost 40 years ago. Thus* his signature and stamp or professional liability are on the drawings and calculations as currently completed. If you intend to delay this project even further by pursuing this matter : to absurdity, then I suggest you urge the soils engineer to step up to : : the plate and sign his name to the drawings as the new engineer of ; record- But if not. then leave the drawings as currently changed on sheets 11, 17 and S-l? and let the Owner get on Wath 2nd story addition. It is not likely that this soils engineer can be expected to cooperate any further on this project. I Thank Plato Carp Consultant 3169 Chelsea Park Circle * Spring Valley, CA 91978 - PH (619) 670-0895 • FAX (619) 477-3669 ESGIL Fax: 18585601576 Nov 4 '99 12=57 P. 03 PLATO CARPADAKIS RESPONSE TO ESGIL COMMENTS - SET II- Plan Check No. 99-2396 PIAMS - item B A "Special inspection program " form has been filled1 out'/, signed by the project engineer of record and submitted to teheCarlsba<3 Building Dep't together with the initial corrections when /they were done -and- the second set of drawings was sent to "Esgil"- The rodket.scientists at the counter apparently did not include this form in| their transfer of drawings to Esgil, If this form is so important to you, please call the.building dep't and ask them about it. - It is probably laying somewhere in their files. FOUNDATION REQUIREMENTS - item 11, A & B Don't ask the Owner or Contractor to provide any letter or any other report(s) in writina from the Soils Engineer since it is not in their power to force him to write such letters/reports if he chooses not to do so. You are asking for something that is unlikely to be accomplished if the engineer is unwilling to cooperate. There is already a project engineer who has' accepted liability for the project. item 11, C This note has already been added to sht-11 See foundation notes The details on sheet S-l show the footing to be 12" min, deep and not 12" max. item 22 Note - 12 on sht-1 and all reference to an additional water heater have been deleted solely for planchecker's.benefit 3169 Chelsea Park Circle - Spring Valley, CA 91978 - PH {€19)670-0895 . FAX (619) 477-3669