Loading...
HomeMy WebLinkAbout2816 RANCHO COSTERO; ; CB151291; Permit04-28-2015 City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Piumbing/Mechanical/Electrical (PME) Permit Permit No:CB151291 Building Inspection Request Line (760) 602-2725 Job Address: Permit Type: Parcel No: Reference #: PC #: Project Title: 2816 RANCHO COSTERO CBAD PIVIE 2218111300 Lot#: WHITTON: REPLACE AC & FURNACE Status: Applied: Entered By: Plan Approved: Issued: Inspect Area: ISSUED 04/28/2015 JIVIA 04/28/2015 04/28/2015 Applicant: THOMPSON HEATING & AIR Owner: WHITTON DAVID A REVOCABLE TRUST 09-04-09 2531 BRADLEY ST OCEANSIDE CA 92056 760-471-5800 2816 RANCHO COSTERO CARLSBAD CA 92009 Plumbing Fees Electrical Fees Mechanical Fees Otiier PME Fees $0.00 $0.00 $160.00 $0.00 TOTAL PERMIT FEES $160.00 Total Fees: $160.00 Total Payments To Date: $160.00 Balance Due: $0.00 Inspector: FINAL APPROVAL^ Date: ^ • " A Clearance: NOTICE: Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively refen-ed to as "fees/exactions." You have 90 days from the date this pennit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attacl<, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which vou have previously been given a NOTICE similar to this, or as to which the statute of limitations has previouslv othen/vise expired. THE FOLLOWING APPROVALS REQUIRED PRIOR TO PERMIT ISSUANCE: nPLANNING ]ENGINEERING nBUILDING nPIRE nHEALTH nHAZMAT/APCD C City of Carlsbad Building Permit Application 1635 Faraday Ave., Carlsbad, CA 92008 Pti: 760-602-2719 Fax:760-602-8558 email: building@carlsbadca.gov www.carlsbadca.gov JOB ADDRESS Plan Check No. C&lS- |2^l Est. Value Plan Ck. Deposit Date SUITE«/SPACE*/UNIT* SWPPP CT/PROJECT # PHASE # # OF UNITS # BEDROOMS # BATHROOMS TENANT BUSINESS NAME CONSTR. TYPE OCC GROUP DESCRIPTION OF WORK: Includa Square Feet of Affected AreaTs; J~ ~\ EXISTING USE PROPOSED USE GARAGE (SF) PATIOS (SF) DECKS (SF) FIREPLACE YESr~l# NOl I AIR CONDITIONING YES I I NO I I FIRE SPRINKLERS YES I |NO| I APPLICANT NAME Primary Contact PROPERTY OWNER ADDRESS, ADDRESS , ^ CITY , STATE ZIP CITJf % ' SIATE ZIP PHONE _ ^ , ^ ^ FAX CITY . STATE PHONE I FAX EMAIL DESIGN PROFESSIONAL CONTRACTOR BUS. NAME ADDRESS Z I, ^1 T CITY ' V / STATE ^ Z|£ ADDRESS CITY ' V / STATE, - ZIE, PHQSE , / -y-V I FAX CITY STATE PHONE FAX EMAIL EMAIL •E LLC.«_ CITY BUS. LIC.# (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law (Chapter 9. commending with Section 7000 of Division 3 of the Business and Professions Code) or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500)). WORKEIRS' COMPENIATION Worliers' Compensation Declaration: / herefcy affirm under pena//y ol perjury one of the following declarations: • I liave and will maintain a certificate of consent to self-insure for worlters' compensation as provided by Section 3700 of the Labor Code, for the performance of ttie worit for whicti this permit is issued. ^^Uiave and will maintain workers' compensation, as r^uired by Section 3700 of tlie Labor Code, for the perfomiara^ of the wori( for which this oermit is issueit.Uy worlters' compensation ins/rancafcamer.and policy number are: Insurance Co A/ 0 T ^ ^ C- Policy No. A'^^-^^'^l C-O / J> Expiration Date 'Z / ^j / This section need not be completed if the permit is for one hundfed dollars ($100) or less. I I Certificate of Exemption: I certify that in the performanffi^the worl< for which this pemiit is issued, I shall not employ any person in any manner so as to become subject to the Worlsers' Compensation Laws of Califomia. 1WARNING: Failure to secure workers^pmpensatlon coverage is unlawful, and shali subject an employer to criminal penalties and civil fines up to one hundred thousand dollars (&100,000), in addition to the cost of compensation, damjajj^f^rovided for in Section 37()^lsrtheJjrt/or code, interest and attomey's fees. If CONTRACTOR SIGNATURE 0A5ENT DATE ^1 OMf NK»-BUILDeR OECLARATION / hereby affirm that i am exempt from Contractor's License Law for the following reason: I I I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). I I I, as owner of the property, am exclusively contracting with licensed contractors to constmct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts ibr such projects with contractor(s) licensed pursuant to the Contractor's License Law). I I I am exempt under Section Business and Professions Code for this reason: 1.1 personally plan to provide the major labor and materials for construction of the proposed property improvement. Qves I iNo 2.1 (have / have not) signed an application for a building perniit for the proposed work. 3,1 have contracted with the following person (firm) to provide the proposed constmction (include name address / phone / contractors' license number): 4.1 plan to provide portions of the work, but I have hired the following person to coordinate, supen/ise and provide the major work (include name / address / phone / contractors' license number): 5,1 will provide some of the work, but I have contrxted (hired) the following persons to provide the work indicated (include name / address / phone / type of work): ^eS'pROPERTY OWNER SIGNATURE •AGENT DATE COMPLETE THIS SECTION FOR NON-RESIDENTIAL BUILDING PERIMITS ONLY Is the applicant or future building occupant required to submit a business plan, acutely hazanJous materials registration form or risk management and prevention program under Sections 25505,25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? 'Ves No Is the applicant or future buikiing occupant required to obtain a pemiit from the air pollution control district or air quality management district? Yes No Is the facility to be constmcted within 1,000 feet of the outer boundary of a school site? Yes No IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance of the iwork this permit is Issued (Sec. 3097 (i) Civil Code). Lender's Name Lender's Address APPLICANT CERTIFICATION I cerU^ that I have lead the application and state that the ab(m infbnriation is collect and that the infbimation on ft^ I hereby authorize representative of the City of Carlsbad to enter upon the above mentioned property for inspedbn purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HAFiMLESS THE CfTY OF CARLSBAD AGAINST ALL LIABILmES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: An OSHA permit is required for excavations over 5'0' deeo#«f demolitbn or constructfon of structures over 3 stories in height. EXPIF(ATION: Every permit issued by the Building Offidalupdenne provisbns of this Code shall expire by limitatfon and beconne null and void if the buikJing or vwrk authorized by such pemnit is not commenced within 180 days from the date of such permit or if the buil^jDgflftok authorgeiby such permit is suspended or abandoned at any tinne after the vmrk is commenced fo&a period of 1 SQ days (Sectton 106.4.4 Unifomi Building Code). ^APPLICANT'S SIGNATURE DATE STOP: THIS SECTION NOT REQUIRED FOR BUILDING PERMIT ISSUANCE. Complete the following ONLY if a Certificate of Occupancy will be requested at final inspection. Fax (760) 602-8560, Email buildinqtajcailsbadca.qov or Mail the completed form to City of Cartsbad, Building Division 1635 Faraday Avenue, Cartsbad, Califomia 92008. C0#: (Office Use Only) CONTACT NAME OCCUPANT NAME ADDRESS BUILDING ADDRESS STATE ZIP STATE ZIP Carlsbad CA PHONE OCCUPANT'S BUS. LIC. No. DELIVERY OPTIONS PICK UP: CONTACT (Listed above) OCCUPANT (Listed above) CONTRACTOR (On Pg. 1) MAIL TO: CONTACT (Listed above) OCCUPANT (Listed above) CONTRACTOR (On Pg. 1) MAIL / FAX TO OTHER: ASSOCIATED CB#- NO CHANGE IN USE / NO CONSTRUCTION CHANGE OF USE / NO CONSTRUCTION jeSAPPLICANT'S SIGNATURE DATE Inspection List Permtt#: CB151291 Type: PME WHITTON: REPLACE AC & FURNACE Date Inspection Item Inspector Act Comments 04/30/2015 43 AirCond/Furnace Set - Rl 04/30/2015 43 AlrCond/Furnace Set PD AP 04/30/2015 49 Final Mechanical - Rl 04/30/2015 49 Final Mechanical PD AP Friday, May 01, 2015 Page 1 of 1 CERTIFICATE OF VERIFICATION CF3R-MCH-20-H Duct Leakage Diagnostic Test (Page 1 of 3) Project Name: Whitton Enforcement Agency: Carlsbad City of Permit Number: on site Dwelling Address: 2816 Rancho Costero City: Carlsbad Zip Code: 92009 A. System Information 01 Space Conditioning System Identification or Name System 2 02 Space Conditioning System Location or Area Served Uptairs 03 Building Type from CF-IR Single family 04 Verified Low Leakage Ducts in Conditioned Space (VLLDCS) Credit from CFIR? No, credit is not taken 05 Verified Low Leakage Air Handling Unit Credit from CFIR? No, credit is not taken 06 Duct System Compliance Category Alteration MCH-20cl - Complete Replacement or Altered Duct System B. Duct Leakage Diagnostic Test 01 Condenser Nominal Cooling Capacity (ton) 2 02 Heating Capacity (kBtu/h) 43 03 Conditioned Floor Area served by this HVAC system (ft2) 1300 04 Duct Leakage Test Condition Test final 05 Duct Leakage Test Method Total leakage 06 Leakage Factor 0.15 07 Air Handling Unit Airflow (AHUAirflow) Determination Method Cooling system method 08 Measured AHUAirflow This field or section is not applicable 09 Calculated Target Allowable Duct Leakage Rate (cfm) 120 10 Actual duct leakage rate from leakage test measurement (cfm) 91 11 Compliance Statement: System passes leakage test 12 Notes: Registration Number: 215-A0107246A-M2000003A-M20A Registration DateAime: 2015-04-23 16:06:42 HERS Provider: CalCERTS Report Generated: 2015-04-23 16:06:16 CA Building Energy Efficiency Standards 2013 Residential Compliance Report Version: 2014-05-08 Schema Version: 0.51SDD CERTIFICATE OF VERIFICATION CF3R-MCH-20-H Duct Leakage Diagnostic Test (Page 2 of 3) C. Additional Requirements for Compliance 01 System was tested in its normal operation condition. No temporary taping allowed. 02 Outside air (OA) ducts for Central Fan Integrated (CFI) ventilation systems, shall not be sealed/taped off during duct leakage testing. CFI OA ducts that utilize controlled motorized dampers, that open only when OA ventilation is required to meet ASHRAE Standard 62.2, and close when OA ventilation is not required, may be configured to the closed position during duct leakage testing. 03 All supply and return register boots were sealed to the drywall. 04 Building cavities were not used as plenums or platform returns in lieu of ducts. 05 If cloth backed tape was used it was covered with Mastic and draw bands. 06 All connection points between the air handler and the supply and return plenums are completely sealed. 07 If the system complies using the Smoke Test method, the smoke test was conducted in accordance with the requirements of Reference Residential Appendix RA3.1.4.3.6. Systems that comply using smoke test shall not be included in sample groups for HERS verification compliance. 08 Verification Status: Pass - all applicable requirements are met 09 Correction Notes for this table: The responsible persons signature on this compliance document affirms that all applicable requirements in this table have been met unless otherwise noted in the Verification Status and the Corrections Notes in this table. D. Determination of HERS Verification Compliance All applicable sections of this document shall Indicate compliance with the specified verification protocol requirements in order for this Certificate of Verification as a whole to be determined to be in compliance. 01 Complies: All specified verification protocol requirements on this document are met. Registration Number: 215-A0107246A-M2000003A-M20A Registration Date/Time: 2015-04-23 16:06:42 HERS Provider: CalCERTS CA Building Energy Efficiency Standards Report Version: 2014-05-08 Report Generated: 2015-04-23 16:06:16 2013 Residential Compliance Schema Version: 0.51SDD CERTIFICATE OF VERIFICATION CF3R-MCH-20-H Duct Leakage Diagnostic Test (Page 3 of 3 ) Documentation Author's Declaration Statement 1.1 certify that this Certificate of Verification documentation is accurate and complete. Documentation Author Nanne: Jason Solarez Documentation Author Signature: ^ Company: Air-Tite Duct Testing Date Signed: 2015-04-23 16:06:42 Address: 2386 Warmlands Ave CEA/ HERS Certification Identification (if applicable): City/State/Zip: Vista CA 92084 Phone: 760-231-9444 Responsible Person's Declaration statement 1 certify the following under penalty of perjury, under the laws of the State of California: 1. The information provided on this Certificate of Verification is true and correct. 2. lam the certified HERS Rater who performed the verification identified and reported on this Certificate of Verification (responsible rater). 3. The installed features, materials, components, manufactured devices, or system performance diagnostic results that require HERS verification identified on this Certificate of Verification comply with the applicable requirements in Reference Appendices RA2, RA3, and the requirements specified on the Certificate of Compliance for the building approved by the enforcement agency. 4. The information reported on applicable sections of the Certificate(s) of Installation (CF2R) signed and submitted by the person(s) responsible for the construction or installation conforms to the requirements specified on the Certificate(s) of Compliance (CFIR) approved by the enforcement agency. 5. 1 will ensure that a registered copy of this Certificate of Verification shall be posted, or made available with the building permit(s] Issued for the building, and made available to the enforcement agency for all applicable Inspections. 1 understand that a registered copy of this Certificate of Verification is required to be included with the documentation the builder provides to the building owner at occupancy. Builder Or Installer Information As Shown On The Certificate Of Installation Company Name (Installing Subcontractor, General Contractor, or Builder/Owner): THOMPSON HEATING AND AIR CONDITIONING Responsible Builder or Installer Name: Garett Baird CSLB License: 974400 HERS Provider Data Registry Information Sample Group Number (if applicable): Dwelling Test Status in Sample Group (If applicable) Tested HERS Rater Information HERS Rater Company Name: Air-Tite Duct Testing Responsible Rater Name: Jason Solarez Responsible Rater Signature: Responsible Rater Certification Number w/ this HERS Provider: CC2006013 Date Signed: 2015-04-23 16:06:42 Oigitally signed by CalCERTS. Ttiis digital signature is provided in order to secure the content oftliis registered document and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 215-A0107246A-M2000003A-M20A CA Building Energy Efficiency Standards 2013 Residential Compliance Registration Date/Time: 2015-04-23 16:06:42 HERS Provider: CalCERTS Report Version: 2014-05-08 Report Generated: 2015-04-23 16:06:16 Schema Version: 0.51SDD CERTIFICATE OF INSTALLATION CF2R-MCH-01-E Space Conditioning Systems, Ducts, and Fans (Page 1 of 7) Project Name: Whitton Enforcement Agency: City of Carlsbad Permit Number: on site Dwelling Address: 2816 Rancho Costero City: Carlsbad Zip Code: 92009 A. General Information 01 Dwelling Unit Name Whitton 02 Climate Zone 7 03 Dwelling Unit Conditioned Floor Area (ft2) 3800 04 Number of space conditioning (SC) systems being altered in this dwelling unit. 2 05 Certificate of Compliance Type Prescriptive alterations (CFIR-ALT) 06 Method used to calculate HVAC loads NotApplicableEquipmentChangeout 07 Calculated dwelling unit Sensible Cooling Load (Btuh) This field or section is not applicable 08 Calculated Dwelling Unit Heating Load (Btuh) This field or section is not applicable MCH-Olb Prescriptive Alterations - Space Conditioning Systems Ducts and Fans B. Space Conditioning (SC) System Information 01 02 03 04 OS 06 07 08 09 10 SC System Identification or Name SC System Location or Area Served CFA served by this SC System (ft2) Is the SC system a ducted system? Installing a refrigerant containing component? Installing new SC system components? Installing more than 40 feet of ducts? Installing entirely new duct system? Installing entirely new SC system? Alteration Type System 1 Downstairs 2500 Yes Yes Yes No No No Altered space conditioning system System 2 Uptairs 1300 Yes Yes Yes No No No Altered space conditioning system Registration Number: 215-A0107246A-IV10100002A-0000 CA Building Energy Efficiency Standards - 2013 Residential Compliance Registration Date/Time: 2015-04-23 17:16:52 Report Version: 2014-05-13 Schema Version; 0.555SDD HERS Provider: CalCERTS Report Generated: 2015-04-23 15:15:07 CERTIFICATE OF INSTALLATION CF2R-(VICH-01-E Space Conditioning Systems, Ducts, and Fans (Page 2 of 7) C. Space Conditioning (SC) System Alterations Compliance Information 01 02 03 04 05 06 07 08 09 10 11 12 13 System Identification or Name Heating System Type Altered Heating Component Heating Efficiency Type Heating Minimum Efficiency Value Cooling System Type Altered Cooling Component Cooling Efficiency Type Cooling Minimum Efficiency Value Required Thermostat Type New or Replaced Duct Length New Duct R-Value Central Fan Integrated (CFI) Ventilation System Status System 1 Central gas furnace All new heating componen ts AFUE 0.78 Central split AC All new cooling components SEER 13 Setback LTE40Ft R6 Not a CFI system System 2 Central gas furnace All new heating componen ts AFUE 0.78 Central split AC All new cooling components SEER 13 Setback LTE40Ft R6 Not a CFI system D. Installed Heating Equipment information 01 02 03 04 05 06 07 System Identification or Name Heating Efficiency Type Heating Efficiency Value Heating Unit Manufacturer Heating Unit Model Number Heating Unit serial number Rated Heating Capacity, Output (BTUH) System 1 AFUE 0.78 Maytag pgc2tal00cvcl pggl50225653 80000 System 2 AFUE 0.78 Maytag Mgc2sa054c23al mggl50315670 43200 Notes: Registration Number: 215-A0107246A-M0100002A-0000 CA Building Energy Efficiency Standards - 2013 Residential Compliance Registration Date/Time: 2015-04-23 17:16:52 Report Version: 2014-05-13 Schema Version: 0.555SDD HERS Provider: CalCERTS Report Generated: 2015-04-23 15:15:07 CERTIFICATE OF INSTALLATION CF2R-MCH-01-E Space Conditioning Systems, Ducts, and Fans (Page 3 of 7 ) E. Installed Cooling Equipment information: 01 02 03 04 05 06 07 08 Condenser or Package Unit System Identification or Name Cooling Efficiency Type Cooling Efficiency Value Condenser or Package Unit Manufacturer Condenser or Package Unit Model Number Condenser or Package Unit Serial Number System Rated Cooling Capacity at Design Conditions (BTUH) Condenser Rated Nominal Capacity (ton) System 1 SEER 13 Maytag csa4bf060kc csfl40805664 60000 5 System 2 SEER 14 Maytag csa4be024ka csfl50102449 24000 2 Notes: F. Extension of Existing Duct System, Greater Than 40 Feet This section does not apply to this project. G. Installed Duct System information This section does not apply to this project. H. Installed Air Filter Device Information This section does not apply to this project. I. Air Filter Device Requirements This section does not apply to this project. Registration Number: 215-A0107246A-M0100002A-0000 CA Building Energy Efficiency Standards - 2013 Residential Compliance Registration Date/Time: 2015-04-23 17:16:52 Report Version: 2014-05-13 Schema Version: 0.555SDD HERS Provider: CalCERTS Report Generated: 2015-04-23 15:15:07 CERTIFICATE OF INSTALLATION CF2R-MCH-01-E Space Conditioning Systems, Ducts, and Fans (Page4of 7) J. HERS Verification Requirements 01 02 03 04 05 06 07 08 09 10 MCH20 MCH21 MCH22 MCH23 MCH25 MCH28 SC System Identification or Name SC System Location or Area Served Exemption From Duct Leakage Requirements Duct Leakage Test Exemption from Minimum R-Value for Ducts In Conditioned Space Ducts Located In Cond Space Verification AHU Fan Efficacy (W per cfm) AHU Airflow Rate (cfm per ton) Refrigerant Charge Return Duct Design Table 150.0-C or D System 1 Downstairs Altered duct system has less than 40 ft of duct in unconditioned spaces No Not applicable No No No No No System 2 Uptairs No exemptions Yes Not applicable No No No No No Registration Number: 215-A0107246A-M0100002A-0000 CA Building Energy Efficiency Standards - 2013 Residential Compliance Registration Date/Time: 2015-04-23 17:16:52 Report Version: 2014-05-13 Schema Version: 0.555SDD HERS Provider: CalCERTS Report Generated: 2015-04-23 15:15:07 CERTIFICATE OF INSTALLATION CF2R-MCH-01-E Space Conditioning Systems, Ducts, and Fans (Page 5 of 7) K. Space Conditioning Systems, Ducts and Fans Mandatory Requirements and Additional Measures Note: Additional mandatory requirements from Section 150.0 that are not listed here may be applicable to some systems. These requirements may be applicable to only newly Installed equipment or portions of the system that are altered. Existing equipment may be exempt from these requirements. Heating Equipment 01 Equipment Efficiency: All heating equipment must meet the minimum efficiency requirements of Section 110.1 and Section 110.2(a) and the Appliance Efficiency Regulations. 02 Controls: All unitary heating systems, including heat pumps, must be controlled by a setback thermostat. These thermostats must be capable of allowing the occupant to program the temperature set points for at least four different periods in 24 hours. See Sections 150.0(i), 110.2(b). 03 Sizing: Heating load calculations must be done on portions of the building served by new heating systems to prevent inadvertent undersizing or oversizing. See sections 150.0(h)l and 2). 04 Furnace Temperature Rise: Central forced-air heating furnace installations must be configured to operate at or below the furnace manufacturer's maximum inlet-to-outlet temperature rise specification. See Section 150.0(h)4. 05 Standby Losses and Pilot Lights: Fan-type central furnaces may not have a continuously burning pilot light. Section 110.5 and Section 110.2(d). Cooling Equipment 06 Equipment Efficiency: All cooling equipment must meet the minimum efficiency requirements of Section 110.1 and Section 110.2(a) and the Appliance Efficiency Regulations. 07 Refrigerant Line Insulation: All refrigerant line insulation in split system air conditioners and heat pumps must meet the R-value and protection requirements of Section 150.0(j)2 and 3, and Section 150.0(m)9. 08 Condensing Unit Location: Condensing units shall not be placed within five (5) feet of a dryer vent outlet. See Section 150.0(h)3A. 09 Sizing: Cooling load calculations must be done on portions of the building served by new cooling systems to prevent inadvertent undersizing or oversizing. See Section 150.0(h)l and 2. Air Distribution System Ducts, Plenums and Fans •10 Insulation: In all cases, unless ducts are enclosed entirely in directly conditioned space, the minimum duct insulation value is R-6. Note that higher values may be required by the prescriptive or performance requirements. See Section 150.0(m)l. Registration Number: 215-A0107246A-1VI0100002A-0000 Registration Date/Time: 2015-04-23 17:16:52 HERS Provider: CalCERTS CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version: 2014-05-13 Report Generated: 2015-04-23 15:15:07 Schema Version: 0.555SDD CERTIFICATE OF INSTALLATION CF2R-MCH-01-E Space Conditioning Systems, Ducts, and Fans (Page 6 of 7 ) K. Space Conditioning Systems, Ducts and Fans Mandatory Requirements and Additional Measures Note: Additional mandatory requirements from Section 150.0 that are not listed here may be applicable to some systems. These requirements may be applicable to only newly installed equipment or portions of the system that are altered. Existing equipment may be exempt from these requirements. 11 Connections and Closures; All installed air-distribution system ducts and plenums must be, sealed and insulated to meet the requirements of CMC Sections 601.0, 602.0, 603.0, 604.0, 605.0 and ANSI/SMACNA-006-2006: Supply-air and return-air ducts and plenums must be insulated to a minimum installed level of R-6.0 or enclosed entirely in directly conditioned space as confirmed through field verification and diagnostic testing in accordance with the requirements of Reference Residential Appendix RA3.1.4.3.8. Heat Pump Thermostat 12 A thermostat shall be installed that meets the requirements of Section 110.2(b) and Section 110.2(c). 13 The thermostat shall be installed in accordance with the manufacturers published installation specifications 14 First stage of heating shall be assigned to heat pump heating. 15 Second stage back up heating shall be set to come on only when the indoor set temperature cannot be met. The responsible person signature on this compliance document affirms that all applicable requirements in this table have been met. Registration Number: 215-A0107246A-IVI0100002A-0000 CA Building Energy Efficiency Standards - 2013 Residential Compliance Registration Date/Time: 2015-04-23 17:16:52 Report Version: 2014-05-13 Schema Version: 0.555SDD HERS Provider: CalCERTS Report Generated: 2015-04-23 15:15:07 CERTIFICATE OF INSTALLATION CF2R-MCH-01-E Space Conditioning Systems, Ducts, and Fans (Page 7 of 7 ) Documentation Author's Declaration Statement 1.1 certify that this Certificate of Installation documentation is accurate and complete. Documentation Author Name: Baird, Garett Documentation Author Signature: ^aA£tt uScmd Company: THOMPSON HEATING AND AIR CONDITIONING Signature Date: 2015-04-23 17:16:52 Address: 2531 BRADLEY STREET CEA/ HERS Certification Identification (if applicable): Clty/State/Zlp: OCEANSIDE CA 92056 Phone: (760) 471-5800 Responsible Person's Declaration statement 1 certify the following under penalty of perjury, under the laws of the State of California: 1. The information provided on this Certificate of Installation is true and correct. 2. 1 am eligible under Division 3 of the Business and Professions Code In the applicable classification to accept responsibility for the system design, construction, or installation of features, materials, components, or manufactured devices for the scope of work identified on this Certificate of Installation, and attest to the declarations in this statement (responsible builder/installer), otherwise 1 am an authorized representative of the responsible builder/installer. 3. The constructed or installed features, materials, components or manufactured devices (the installation) identified on this Certificate of Installation conforms to all applicable codes and regulations, and the installation conforms to the requirements given on the plans and specifications approved by the enforcement agency. 4. 1 reviewed a copy of the Certificate of Compliance approved by the enforcement agency that identifies the specific requirements for the scope of construction or installation identified on this Certificate of Installation, and 1 have ensured that the requirements that apply to the construction or Installation have been met. 5. 1 will ensure that a registered copy of this Certificate of Installation shall be posted, or made available with the building permlt(s) issued for the building, and made available to the enforcement agency for all applicable inspections. 1 understand that a registered copy of this Certificate of Installation is required to be Included with the documentation the builder provides to the building owner at occupancy. Responsible Builder/Installer Name: Baird, Garett Responsible Builder/Installer Signature: ^ Company Name: (Installing Subcontractor or General Contractor or Builder/Owner) THOMPSON HEATING AND AIR CONDITIONING Position With Company (Title): Owner Address: 2531 BRADLEY STREET CSLB License: 974400 Cltv/State/Zlp: OCEANSIDE CA 92056 Phone: Date Signed: (760)471-5800 2015-04-23 17:16:52 Digitally signed by CalCERTS. This digital signature is provided in order to secure the content of this registered document and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 215-A0107246A-M0100002A-0000 CA Building Energy Efficiency Standards - 2013 Residential Compliance Registration Date/Time: 2015-04-23 17:16:52 Report Version: 2014-05-13 Schema Version: 0.555SDD HERS Provider: CalCERTS Report Generated: 2015-04-23 15:15:07