HomeMy WebLinkAbout2816 RANCHO COSTERO; ; CB151291; Permit04-28-2015
City of Carlsbad
1635 Faraday Av Carlsbad, CA 92008
Piumbing/Mechanical/Electrical (PME) Permit
Permit No:CB151291
Building Inspection Request Line (760) 602-2725
Job Address:
Permit Type:
Parcel No:
Reference #:
PC #:
Project Title:
2816 RANCHO COSTERO CBAD
PIVIE
2218111300 Lot#:
WHITTON: REPLACE AC & FURNACE
Status:
Applied:
Entered By:
Plan Approved:
Issued:
Inspect Area:
ISSUED
04/28/2015
JIVIA
04/28/2015
04/28/2015
Applicant:
THOMPSON HEATING & AIR
Owner:
WHITTON DAVID A REVOCABLE TRUST 09-04-09
2531 BRADLEY ST
OCEANSIDE CA 92056
760-471-5800
2816 RANCHO COSTERO
CARLSBAD CA 92009
Plumbing Fees
Electrical Fees
Mechanical Fees
Otiier PME Fees
$0.00
$0.00
$160.00
$0.00
TOTAL PERMIT FEES $160.00
Total Fees: $160.00 Total Payments To Date: $160.00 Balance Due: $0.00
Inspector:
FINAL APPROVAL^
Date: ^ • " A Clearance:
NOTICE: Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively
refen-ed to as "fees/exactions." You have 90 days from the date this pennit was issued to protest imposition of these fees/exactions. If you protest them, you must
follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for
processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attacl<,
review, set aside, void, or annul their imposition.
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity
changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any
fees/exactions of which vou have previously been given a NOTICE similar to this, or as to which the statute of limitations has previouslv othen/vise expired.
THE FOLLOWING APPROVALS REQUIRED PRIOR TO PERMIT ISSUANCE: nPLANNING ]ENGINEERING nBUILDING nPIRE nHEALTH nHAZMAT/APCD
C City of
Carlsbad
Building Permit Application
1635 Faraday Ave., Carlsbad, CA 92008
Pti: 760-602-2719 Fax:760-602-8558
email: building@carlsbadca.gov
www.carlsbadca.gov
JOB ADDRESS
Plan Check No. C&lS- |2^l
Est. Value
Plan Ck. Deposit
Date
SUITE«/SPACE*/UNIT*
SWPPP
CT/PROJECT # PHASE # # OF UNITS # BEDROOMS # BATHROOMS TENANT BUSINESS NAME CONSTR. TYPE OCC GROUP
DESCRIPTION OF WORK: Includa Square Feet of Affected AreaTs; J~ ~\
EXISTING USE PROPOSED USE GARAGE (SF) PATIOS (SF) DECKS (SF) FIREPLACE
YESr~l# NOl I
AIR CONDITIONING
YES I I NO I I
FIRE SPRINKLERS
YES I |NO| I
APPLICANT NAME
Primary Contact
PROPERTY OWNER
ADDRESS, ADDRESS , ^
CITY , STATE ZIP CITJf % ' SIATE ZIP
PHONE _ ^ , ^ ^ FAX
CITY . STATE
PHONE I FAX
EMAIL
DESIGN PROFESSIONAL CONTRACTOR BUS. NAME
ADDRESS Z I, ^1 T
CITY ' V / STATE ^ Z|£
ADDRESS
CITY ' V / STATE, - ZIE,
PHQSE , / -y-V I FAX
CITY STATE
PHONE FAX
EMAIL EMAIL
•E LLC.«_ CITY BUS. LIC.#
(Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law (Chapter 9. commending with Section 7000 of Division 3 of the Business and Professions Code) or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500)).
WORKEIRS' COMPENIATION
Worliers' Compensation Declaration: / herefcy affirm under pena//y ol perjury one of the following declarations:
• I liave and will maintain a certificate of consent to self-insure for worlters' compensation as provided by Section 3700 of the Labor Code, for the performance of ttie worit for whicti this permit is issued.
^^Uiave and will maintain workers' compensation, as r^uired by Section 3700 of tlie Labor Code, for the perfomiara^ of the wori( for which this oermit is issueit.Uy worlters' compensation ins/rancafcamer.and policy
number are: Insurance Co A/ 0 T ^ ^ C- Policy No. A'^^-^^'^l C-O / J> Expiration Date 'Z / ^j /
This section need not be completed if the permit is for one hundfed dollars ($100) or less.
I I Certificate of Exemption: I certify that in the performanffi^the worl< for which this pemiit is issued, I shall not employ any person in any manner so as to become subject to the Worlsers' Compensation Laws of
Califomia. 1WARNING: Failure to secure workers^pmpensatlon coverage is unlawful, and shali subject an employer to criminal penalties and civil fines up to one hundred thousand dollars (&100,000), in
addition to the cost of compensation, damjajj^f^rovided for in Section 37()^lsrtheJjrt/or code, interest and attomey's fees. If
CONTRACTOR SIGNATURE 0A5ENT DATE ^1
OMf NK»-BUILDeR OECLARATION
/ hereby affirm that i am exempt from Contractor's License Law for the following reason:
I I I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's
License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for
sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale).
I I I, as owner of the property, am exclusively contracting with licensed contractors to constmct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of
property who builds or improves thereon, and contracts ibr such projects with contractor(s) licensed pursuant to the Contractor's License Law).
I I I am exempt under Section Business and Professions Code for this reason:
1.1 personally plan to provide the major labor and materials for construction of the proposed property improvement. Qves I iNo
2.1 (have / have not) signed an application for a building perniit for the proposed work.
3,1 have contracted with the following person (firm) to provide the proposed constmction (include name address / phone / contractors' license number):
4.1 plan to provide portions of the work, but I have hired the following person to coordinate, supen/ise and provide the major work (include name / address / phone / contractors' license number):
5,1 will provide some of the work, but I have contrxted (hired) the following persons to provide the work indicated (include name / address / phone / type of work):
^eS'pROPERTY OWNER SIGNATURE •AGENT DATE
COMPLETE THIS SECTION FOR NON-RESIDENTIAL BUILDING PERIMITS ONLY
Is the applicant or future building occupant required to submit a business plan, acutely hazanJous materials registration form or risk management and prevention program under Sections 25505,25533 or 25534 of the
Presley-Tanner Hazardous Substance Account Act? 'Ves No
Is the applicant or future buikiing occupant required to obtain a pemiit from the air pollution control district or air quality management district? Yes No
Is the facility to be constmcted within 1,000 feet of the outer boundary of a school site? Yes No
IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF
EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT.
CONSTRUCTION LENDING AGENCY
I hereby affirm that there is a construction lending agency for the performance of the iwork this permit is Issued (Sec. 3097 (i) Civil Code).
Lender's Name Lender's Address
APPLICANT CERTIFICATION
I cerU^ that I have lead the application and state that the ab(m infbnriation is collect and that the infbimation on ft^
I hereby authorize representative of the City of Carlsbad to enter upon the above mentioned property for inspedbn purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HAFiMLESS THE CfTY OF CARLSBAD
AGAINST ALL LIABILmES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT.
OSHA: An OSHA permit is required for excavations over 5'0' deeo#«f demolitbn or constructfon of structures over 3 stories in height.
EXPIF(ATION: Every permit issued by the Building Offidalupdenne provisbns of this Code shall expire by limitatfon and beconne null and void if the buikJing or vwrk authorized by such pemnit is not commenced within
180 days from the date of such permit or if the buil^jDgflftok authorgeiby such permit is suspended or abandoned at any tinne after the vmrk is commenced fo&a period of 1 SQ days (Sectton 106.4.4 Unifomi Building Code).
^APPLICANT'S SIGNATURE DATE
STOP: THIS SECTION NOT REQUIRED FOR BUILDING PERMIT ISSUANCE.
Complete the following ONLY if a Certificate of Occupancy will be requested at final inspection.
Fax (760) 602-8560, Email buildinqtajcailsbadca.qov or Mail the completed form to City of Cartsbad, Building Division 1635 Faraday Avenue, Cartsbad, Califomia 92008.
C0#: (Office Use Only)
CONTACT NAME OCCUPANT NAME
ADDRESS BUILDING ADDRESS
STATE ZIP STATE ZIP
Carlsbad CA
PHONE
OCCUPANT'S BUS. LIC. No.
DELIVERY OPTIONS
PICK UP: CONTACT (Listed above) OCCUPANT (Listed above)
CONTRACTOR (On Pg. 1)
MAIL TO: CONTACT (Listed above) OCCUPANT (Listed above)
CONTRACTOR (On Pg. 1)
MAIL / FAX TO OTHER:
ASSOCIATED CB#-
NO CHANGE IN USE / NO CONSTRUCTION
CHANGE OF USE / NO CONSTRUCTION
jeSAPPLICANT'S SIGNATURE DATE
Inspection List
Permtt#: CB151291 Type: PME WHITTON: REPLACE AC & FURNACE
Date Inspection Item Inspector Act Comments
04/30/2015 43 AirCond/Furnace Set - Rl
04/30/2015 43 AlrCond/Furnace Set PD AP
04/30/2015 49 Final Mechanical - Rl
04/30/2015 49 Final Mechanical PD AP
Friday, May 01, 2015 Page 1 of 1
CERTIFICATE OF VERIFICATION CF3R-MCH-20-H
Duct Leakage Diagnostic Test (Page 1 of 3)
Project Name: Whitton Enforcement Agency:
Carlsbad
City of Permit Number: on site
Dwelling Address: 2816 Rancho Costero City: Carlsbad Zip Code: 92009
A. System Information
01 Space Conditioning System Identification or Name System 2
02 Space Conditioning System Location or Area Served Uptairs
03 Building Type from CF-IR Single family
04 Verified Low Leakage Ducts in Conditioned Space
(VLLDCS) Credit from CFIR?
No, credit is not taken
05 Verified Low Leakage Air Handling Unit Credit from
CFIR?
No, credit is not taken
06 Duct System Compliance Category Alteration
MCH-20cl - Complete Replacement or Altered Duct System
B. Duct Leakage Diagnostic Test
01 Condenser Nominal Cooling Capacity (ton) 2
02 Heating Capacity (kBtu/h) 43
03 Conditioned Floor Area served by this HVAC system (ft2) 1300
04 Duct Leakage Test Condition Test final
05 Duct Leakage Test Method Total leakage
06 Leakage Factor 0.15
07 Air Handling Unit Airflow (AHUAirflow) Determination
Method
Cooling system method
08 Measured AHUAirflow This field or section is not applicable
09 Calculated Target Allowable Duct Leakage Rate (cfm) 120
10 Actual duct leakage rate from leakage test measurement
(cfm)
91
11 Compliance Statement: System passes leakage test
12 Notes:
Registration Number: 215-A0107246A-M2000003A-M20A Registration DateAime: 2015-04-23 16:06:42 HERS Provider: CalCERTS
Report Generated: 2015-04-23 16:06:16 CA Building Energy Efficiency Standards
2013 Residential Compliance
Report Version: 2014-05-08
Schema Version: 0.51SDD
CERTIFICATE OF VERIFICATION CF3R-MCH-20-H
Duct Leakage Diagnostic Test (Page 2 of 3)
C. Additional Requirements for Compliance
01 System was tested in its normal operation condition. No temporary taping allowed.
02
Outside air (OA) ducts for Central Fan Integrated (CFI) ventilation systems, shall not be sealed/taped off during duct leakage
testing. CFI OA ducts that utilize controlled motorized dampers, that open only when OA ventilation is required to meet
ASHRAE Standard 62.2, and close when OA ventilation is not required, may be configured to the closed position during duct
leakage testing.
03 All supply and return register boots were sealed to the drywall.
04 Building cavities were not used as plenums or platform returns in lieu of ducts.
05 If cloth backed tape was used it was covered with Mastic and draw bands.
06 All connection points between the air handler and the supply and return plenums are completely sealed.
07
If the system complies using the Smoke Test method, the smoke test was conducted in accordance with the requirements
of Reference Residential Appendix RA3.1.4.3.6. Systems that comply using smoke test shall not be included in sample
groups for HERS verification compliance.
08 Verification Status: Pass - all applicable requirements are met
09 Correction Notes for this table:
The responsible persons signature on this compliance document affirms that all applicable requirements in this table have
been met unless otherwise noted in the Verification Status and the Corrections Notes in this table.
D. Determination of HERS Verification Compliance
All applicable sections of this document shall Indicate compliance with the specified verification protocol
requirements in order for this Certificate of Verification as a whole to be determined to be in compliance.
01 Complies: All specified verification protocol requirements on this document are met.
Registration Number: 215-A0107246A-M2000003A-M20A Registration Date/Time: 2015-04-23 16:06:42 HERS Provider: CalCERTS
CA Building Energy Efficiency Standards Report Version: 2014-05-08 Report Generated: 2015-04-23 16:06:16
2013 Residential Compliance Schema Version: 0.51SDD
CERTIFICATE OF VERIFICATION CF3R-MCH-20-H
Duct Leakage Diagnostic Test (Page 3 of 3 )
Documentation Author's Declaration Statement
1.1 certify that this Certificate of Verification documentation is accurate and complete.
Documentation Author Nanne:
Jason Solarez
Documentation Author Signature: ^
Company:
Air-Tite Duct Testing
Date Signed:
2015-04-23 16:06:42
Address:
2386 Warmlands Ave
CEA/ HERS Certification Identification (if applicable):
City/State/Zip:
Vista CA 92084
Phone:
760-231-9444
Responsible Person's Declaration statement
1 certify the following under penalty of perjury, under the laws of the State of California:
1. The information provided on this Certificate of Verification is true and correct.
2. lam the certified HERS Rater who performed the verification identified and reported on this Certificate of Verification (responsible rater).
3. The installed features, materials, components, manufactured devices, or system performance diagnostic results that require HERS verification
identified on this Certificate of Verification comply with the applicable requirements in Reference Appendices RA2, RA3, and the requirements
specified on the Certificate of Compliance for the building approved by the enforcement agency.
4. The information reported on applicable sections of the Certificate(s) of Installation (CF2R) signed and submitted by the person(s) responsible for the
construction or installation conforms to the requirements specified on the Certificate(s) of Compliance (CFIR) approved by the enforcement agency.
5. 1 will ensure that a registered copy of this Certificate of Verification shall be posted, or made available with the building permit(s] Issued for the
building, and made available to the enforcement agency for all applicable Inspections. 1 understand that a registered copy of this Certificate of
Verification is required to be included with the documentation the builder provides to the building owner at occupancy.
Builder Or Installer Information As Shown On The Certificate Of Installation
Company Name (Installing Subcontractor, General Contractor, or Builder/Owner):
THOMPSON HEATING AND AIR CONDITIONING
Responsible Builder or Installer Name:
Garett Baird
CSLB License:
974400
HERS Provider Data Registry Information
Sample Group Number (if applicable): Dwelling Test Status in Sample Group (If applicable)
Tested
HERS Rater Information
HERS Rater Company Name:
Air-Tite Duct Testing
Responsible Rater Name:
Jason Solarez
Responsible Rater Signature:
Responsible Rater Certification Number w/ this HERS Provider:
CC2006013
Date Signed:
2015-04-23 16:06:42
Oigitally signed by CalCERTS. Ttiis digital signature is provided in order to secure the content oftliis registered document and in no way implies Registration Provider
responsibility for the accuracy of the information.
Registration Number: 215-A0107246A-M2000003A-M20A
CA Building Energy Efficiency Standards
2013 Residential Compliance
Registration Date/Time: 2015-04-23 16:06:42 HERS Provider: CalCERTS
Report Version: 2014-05-08 Report Generated: 2015-04-23 16:06:16
Schema Version: 0.51SDD
CERTIFICATE OF INSTALLATION CF2R-MCH-01-E
Space Conditioning Systems, Ducts, and Fans (Page 1 of 7)
Project Name: Whitton Enforcement Agency: City of Carlsbad Permit Number: on site
Dwelling Address: 2816 Rancho Costero City: Carlsbad Zip Code: 92009
A. General Information
01 Dwelling Unit Name Whitton 02 Climate Zone 7
03 Dwelling Unit Conditioned Floor Area
(ft2) 3800 04
Number of space conditioning (SC)
systems being altered in this dwelling
unit.
2
05 Certificate of Compliance Type Prescriptive alterations (CFIR-ALT) 06 Method used to calculate HVAC loads NotApplicableEquipmentChangeout
07 Calculated dwelling unit Sensible
Cooling Load (Btuh) This field or section is not applicable 08 Calculated Dwelling Unit Heating Load
(Btuh) This field or section is not applicable
MCH-Olb Prescriptive Alterations - Space Conditioning Systems Ducts and Fans
B. Space Conditioning (SC) System Information
01 02 03 04 OS 06 07 08 09 10
SC System
Identification or
Name
SC System
Location or Area
Served
CFA served
by this SC
System
(ft2)
Is the SC
system a
ducted
system?
Installing a
refrigerant
containing
component?
Installing new SC
system
components?
Installing more
than 40 feet of
ducts?
Installing
entirely
new duct
system?
Installing
entirely new
SC system? Alteration Type
System 1 Downstairs 2500 Yes Yes Yes No No No
Altered space
conditioning
system
System 2 Uptairs 1300 Yes Yes Yes No No No
Altered space
conditioning
system
Registration Number: 215-A0107246A-IV10100002A-0000
CA Building Energy Efficiency Standards - 2013 Residential Compliance
Registration Date/Time: 2015-04-23 17:16:52
Report Version: 2014-05-13
Schema Version; 0.555SDD
HERS Provider: CalCERTS
Report Generated: 2015-04-23 15:15:07
CERTIFICATE OF INSTALLATION CF2R-(VICH-01-E
Space Conditioning Systems, Ducts, and Fans (Page 2 of 7)
C. Space Conditioning (SC) System Alterations Compliance Information
01 02 03 04 05 06 07 08 09 10 11 12 13
System
Identification
or Name
Heating
System Type
Altered
Heating
Component
Heating
Efficiency
Type
Heating
Minimum
Efficiency
Value
Cooling
System Type
Altered
Cooling
Component
Cooling
Efficiency
Type
Cooling
Minimum
Efficiency
Value
Required
Thermostat
Type
New or
Replaced
Duct
Length
New
Duct
R-Value
Central Fan
Integrated
(CFI)
Ventilation
System
Status
System 1 Central gas
furnace
All new
heating
componen
ts
AFUE 0.78 Central
split AC
All new
cooling
components
SEER 13 Setback LTE40Ft R6 Not a CFI
system
System 2 Central gas
furnace
All new
heating
componen
ts
AFUE 0.78 Central
split AC
All new
cooling
components
SEER 13 Setback LTE40Ft R6 Not a CFI
system
D. Installed Heating Equipment information
01 02 03 04 05 06 07
System Identification or
Name Heating Efficiency Type
Heating Efficiency
Value
Heating Unit
Manufacturer
Heating Unit
Model Number
Heating Unit serial
number
Rated Heating Capacity,
Output (BTUH)
System 1 AFUE 0.78 Maytag pgc2tal00cvcl pggl50225653 80000
System 2 AFUE 0.78 Maytag Mgc2sa054c23al mggl50315670 43200
Notes:
Registration Number: 215-A0107246A-M0100002A-0000
CA Building Energy Efficiency Standards - 2013 Residential Compliance
Registration Date/Time: 2015-04-23 17:16:52
Report Version: 2014-05-13
Schema Version: 0.555SDD
HERS Provider: CalCERTS
Report Generated: 2015-04-23 15:15:07
CERTIFICATE OF INSTALLATION CF2R-MCH-01-E
Space Conditioning Systems, Ducts, and Fans (Page 3 of 7 )
E. Installed Cooling Equipment information:
01 02 03 04 05 06 07 08
Condenser or Package Unit
System Identification
or Name
Cooling Efficiency
Type
Cooling Efficiency
Value
Condenser or
Package Unit
Manufacturer
Condenser or
Package Unit
Model Number
Condenser or
Package Unit
Serial Number
System Rated Cooling
Capacity at Design
Conditions (BTUH)
Condenser Rated
Nominal Capacity
(ton)
System 1 SEER 13 Maytag csa4bf060kc csfl40805664 60000 5
System 2 SEER 14 Maytag csa4be024ka csfl50102449 24000 2
Notes:
F. Extension of Existing Duct System, Greater Than 40 Feet
This section does not apply to this project.
G. Installed Duct System information
This section does not apply to this project.
H. Installed Air Filter Device Information
This section does not apply to this project.
I. Air Filter Device Requirements
This section does not apply to this project.
Registration Number: 215-A0107246A-M0100002A-0000
CA Building Energy Efficiency Standards - 2013 Residential Compliance
Registration Date/Time: 2015-04-23 17:16:52
Report Version: 2014-05-13
Schema Version: 0.555SDD
HERS Provider: CalCERTS
Report Generated: 2015-04-23 15:15:07
CERTIFICATE OF INSTALLATION CF2R-MCH-01-E
Space Conditioning Systems, Ducts, and Fans (Page4of 7)
J. HERS Verification Requirements
01 02 03 04 05 06 07 08 09 10
MCH20 MCH21 MCH22 MCH23 MCH25 MCH28
SC System
Identification or
Name
SC System
Location or Area
Served
Exemption
From Duct
Leakage
Requirements
Duct
Leakage
Test
Exemption
from
Minimum
R-Value for
Ducts In
Conditioned
Space
Ducts Located
In Cond Space
Verification
AHU Fan
Efficacy
(W per
cfm)
AHU
Airflow
Rate (cfm
per ton)
Refrigerant
Charge
Return Duct Design
Table 150.0-C or D
System 1 Downstairs
Altered duct
system has
less than 40 ft
of duct in
unconditioned
spaces
No Not
applicable No No No No No
System 2 Uptairs No
exemptions Yes Not
applicable No No No No No
Registration Number: 215-A0107246A-M0100002A-0000
CA Building Energy Efficiency Standards - 2013 Residential Compliance
Registration Date/Time: 2015-04-23 17:16:52
Report Version: 2014-05-13
Schema Version: 0.555SDD
HERS Provider: CalCERTS
Report Generated: 2015-04-23 15:15:07
CERTIFICATE OF INSTALLATION CF2R-MCH-01-E
Space Conditioning Systems, Ducts, and Fans (Page 5 of 7)
K. Space Conditioning Systems, Ducts and Fans Mandatory Requirements and Additional Measures
Note: Additional mandatory requirements from Section 150.0 that are not listed here may be applicable to some systems. These requirements may be applicable to only newly Installed equipment or portions of the
system that are altered. Existing equipment may be exempt from these requirements.
Heating Equipment
01 Equipment Efficiency: All heating equipment must meet the minimum efficiency requirements of Section 110.1 and Section 110.2(a) and the Appliance Efficiency
Regulations.
02 Controls: All unitary heating systems, including heat pumps, must be controlled by a setback thermostat. These thermostats must be capable of allowing the occupant
to program the temperature set points for at least four different periods in 24 hours. See Sections 150.0(i), 110.2(b).
03 Sizing: Heating load calculations must be done on portions of the building served by new heating systems to prevent inadvertent undersizing or oversizing. See sections
150.0(h)l and 2).
04 Furnace Temperature Rise: Central forced-air heating furnace installations must be configured to operate at or below the furnace manufacturer's maximum
inlet-to-outlet temperature rise specification. See Section 150.0(h)4.
05 Standby Losses and Pilot Lights: Fan-type central furnaces may not have a continuously burning pilot light. Section 110.5 and Section 110.2(d).
Cooling Equipment
06 Equipment Efficiency: All cooling equipment must meet the minimum efficiency requirements of Section 110.1 and Section 110.2(a) and the Appliance Efficiency
Regulations.
07 Refrigerant Line Insulation: All refrigerant line insulation in split system air conditioners and heat pumps must meet the R-value and protection requirements of Section
150.0(j)2 and 3, and Section 150.0(m)9.
08 Condensing Unit Location: Condensing units shall not be placed within five (5) feet of a dryer vent outlet. See Section 150.0(h)3A.
09 Sizing: Cooling load calculations must be done on portions of the building served by new cooling systems to prevent inadvertent undersizing or oversizing. See Section
150.0(h)l and 2.
Air Distribution System Ducts, Plenums and Fans
•10 Insulation: In all cases, unless ducts are enclosed entirely in directly conditioned space, the minimum duct insulation value is R-6. Note that higher values may be
required by the prescriptive or performance requirements. See Section 150.0(m)l.
Registration Number: 215-A0107246A-1VI0100002A-0000 Registration Date/Time: 2015-04-23 17:16:52 HERS Provider: CalCERTS
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version: 2014-05-13 Report Generated: 2015-04-23 15:15:07
Schema Version: 0.555SDD
CERTIFICATE OF INSTALLATION CF2R-MCH-01-E
Space Conditioning Systems, Ducts, and Fans (Page 6 of 7 )
K. Space Conditioning Systems, Ducts and Fans Mandatory Requirements and Additional Measures
Note: Additional mandatory requirements from Section 150.0 that are not listed here may be applicable to some systems. These requirements may be applicable to only newly installed equipment or portions of the
system that are altered. Existing equipment may be exempt from these requirements.
11
Connections and Closures; All installed air-distribution system ducts and plenums must be, sealed and insulated to meet the requirements of CMC Sections 601.0,
602.0, 603.0, 604.0, 605.0 and ANSI/SMACNA-006-2006: Supply-air and return-air ducts and plenums must be insulated to a minimum installed level of R-6.0 or
enclosed entirely in directly conditioned space as confirmed through field verification and diagnostic testing in accordance with the requirements of Reference
Residential Appendix RA3.1.4.3.8.
Heat Pump Thermostat
12 A thermostat shall be installed that meets the requirements of Section 110.2(b) and Section 110.2(c).
13 The thermostat shall be installed in accordance with the manufacturers published installation specifications
14 First stage of heating shall be assigned to heat pump heating.
15 Second stage back up heating shall be set to come on only when the indoor set temperature cannot be met.
The responsible person signature on this compliance document affirms that all applicable requirements in this table have been met.
Registration Number: 215-A0107246A-IVI0100002A-0000
CA Building Energy Efficiency Standards - 2013 Residential Compliance
Registration Date/Time: 2015-04-23 17:16:52
Report Version: 2014-05-13
Schema Version: 0.555SDD
HERS Provider: CalCERTS
Report Generated: 2015-04-23 15:15:07
CERTIFICATE OF INSTALLATION CF2R-MCH-01-E
Space Conditioning Systems, Ducts, and Fans (Page 7 of 7 )
Documentation Author's Declaration Statement
1.1 certify that this Certificate of Installation documentation is accurate and complete.
Documentation Author Name:
Baird, Garett
Documentation Author Signature:
^aA£tt uScmd
Company:
THOMPSON HEATING AND AIR CONDITIONING
Signature Date:
2015-04-23 17:16:52
Address:
2531 BRADLEY STREET
CEA/ HERS Certification Identification (if applicable):
Clty/State/Zlp:
OCEANSIDE CA 92056
Phone:
(760) 471-5800
Responsible Person's Declaration statement
1 certify the following under penalty of perjury, under the laws of the State of California:
1. The information provided on this Certificate of Installation is true and correct.
2. 1 am eligible under Division 3 of the Business and Professions Code In the applicable classification to accept responsibility for the system design, construction, or installation of features, materials,
components, or manufactured devices for the scope of work identified on this Certificate of Installation, and attest to the declarations in this statement (responsible builder/installer), otherwise 1 am an
authorized representative of the responsible builder/installer.
3. The constructed or installed features, materials, components or manufactured devices (the installation) identified on this Certificate of Installation conforms to all applicable codes and regulations, and the
installation conforms to the requirements given on the plans and specifications approved by the enforcement agency.
4. 1 reviewed a copy of the Certificate of Compliance approved by the enforcement agency that identifies the specific requirements for the scope of construction or installation identified on this Certificate of
Installation, and 1 have ensured that the requirements that apply to the construction or Installation have been met.
5. 1 will ensure that a registered copy of this Certificate of Installation shall be posted, or made available with the building permlt(s) issued for the building, and made available to the enforcement agency for all
applicable inspections. 1 understand that a registered copy of this Certificate of Installation is required to be Included with the documentation the builder provides to the building owner at occupancy.
Responsible Builder/Installer Name:
Baird, Garett
Responsible Builder/Installer Signature: ^
Company Name: (Installing Subcontractor or General Contractor or Builder/Owner)
THOMPSON HEATING AND AIR CONDITIONING
Position With Company (Title):
Owner
Address:
2531 BRADLEY STREET
CSLB License:
974400
Cltv/State/Zlp:
OCEANSIDE CA 92056
Phone: Date Signed:
(760)471-5800 2015-04-23 17:16:52
Digitally signed by CalCERTS. This digital signature is provided in order to secure the content of this registered document and in no way implies Registration Provider responsibility for the accuracy of the information.
Registration Number: 215-A0107246A-M0100002A-0000
CA Building Energy Efficiency Standards - 2013 Residential Compliance
Registration Date/Time: 2015-04-23 17:16:52
Report Version: 2014-05-13
Schema Version: 0.555SDD
HERS Provider: CalCERTS
Report Generated: 2015-04-23 15:15:07