HomeMy WebLinkAbout2817 AVENIDA VALERA; ; CB920865; PermitI BUILDING PERMIT Permit No: CB920865 08/25/92 10:45 Project No: A9201925 Page I *of 1 Development No: Job 'Address: 2817 AVENIDA VALERA Suite: Permit Type: SINGLE FAMILY DWLNG - DETACHED Parcel No: 216-460-25-00 Lot#: 129 Valuation: 212,693 Construction Type: VN poi5 08/25/?2 oooi 01 02 Occupancy Group: R3/M1 Reference#: 92-636 st&WT IS*~W*~~ Description: 2365 SF.+ 661 SF GARAGE PLAN 4 Applied: 08/24/92 : PHASE 1 Apr/Issue: 08/25/92 Validated By: MDP Appl/Ownr : FIELDSTONE/LA COSTA ASSOC. 619 546-8226 5465 MOREHOUSE DRIVE #250 SAN DIEGO, CA 92121 *** Fees Reauired *** *** Fees Collected & Credits *** Fees : 13,137. Adjustments: Total Fees: 13,13 350.00 12,787.00 it Ext fee Data ------------------ Fee description .................... Building Permit Plan Check Strong Motion Fee or manually enter Enter F.M.F./G.M.F Enter "Y" to Autoc Enter "Y" to Autoc, Enter "Y" to 'Autoc * BUILDING TOTAL Enter "Y" for Plumb Each Plumbing Fixtu Each Building Sewer Each Water Heater and/or V ~ Gas Piping System Each Vacuum Breaker * PLUMBING TOTAL Enter "Y" for Electric Issue Fee > Single Phase Per AMP > * ELECTRICAL TOTAL Enter 'Y' for Mechanical Issue Fee> Install Furn/Ducts > Each Install/Reloc Appliance Vent > Each Hood/Fireplace > * MECHANICAL TOTAL 0 0 0 0 1 9.00 4 4.50 1 6.50 0 125 .25 1035.00 673.00 21.00 2200.00 3871.00 Y 3573.00 362.00 Y 408.00 530.00 Y 12983.00 7.50 Y 40.00 6.50 2.50 2.50 5.00 64.00 10.00 Y 31.25 41.00 15.00 Y 9.00 18.00 6.50 49.00 310.00 06 CITY OF CARLSBAD 2075 Las Palmas Dr., Carlsbad, CA 92009 (619) 438-1161 FINAL BUILDING INSPECTION DEPT: BUILDING *'ENGINEERING FIRE PLANNING U/M WATER PLAN CHECK#: CB920865 PERMIT#: CB920865 PROJECT NAME: 2638 SF + 661 SF GARAGE PLAN 4 PHASE 1 DATE: 04/28/93 PERMIT TYPE: SFD ADDRESS: 2817 AVENIDA VALERA CONTACT PERSON/PHONE#: ALLISON @ FIELDSTONE/438-0468 SEWER DIST: LC WATER DIST: CA ?h?,J APPROVED L&?] APPROVED DATE INSPECTED: INSPECTED DATE BY: INSPECTED: INSPECTED BY: DATE INSPECTED: 5/7 193 APPROVED - DISAPPROVED - DISAPPROVED DISAPPROVED - Y L FINAL BUILDING INSPECTION DEPT: BUILDING ENGINEERING FIRE * U/M LAN CHECK#: CB920854 NIT# : CB920854 rdOJECT NAME: 2391 SF + 628 SF GARAGE 43 SF DECK PHASE 1 PLAN 3 ADDRESS: 2817 VISTA MARIANA CONTACT PERSON/PHONE#: ALLISON @ FIELDSTONE/438-0468 SEWER DIST: LC WATER DIST: CA WATER DATE: 04/28/93 PERMIT TYPE: SFD '. 124 INSPECTED: 1 DISAPPROVED - V INSPECTED DATE BY: INSPECTED DATE BY: INSPECTED,: APPROVED - DISAPPROVED - INSPECTED DATE BY: INSPECTED: APPROVED DISAPPROVED - . FINAL BUILDING INSPECTION DEPT: BUILDING ENGINEERING FIRE PLANNING U/M PLAN CHECK#: CB920865 PERMIT#: CB920865 PROJECT NAME: 2638 SF + 661 SF GARAGE PLAN 4 PHASE 1 ADDRESS: 2817 AVENIDA VALERA WATER DATE : PERMIT 04/28/93 TYPE: SFD CONTACT PERSON/PHONE#: ALLISON @ FIELDSTONE/438-0468 SEWER DIST: LC WATER DIST: CA BY: INSPECTED: APPROVED DISAPPROVED - FINAL BUILDING INSPECTION DEPT: BUILDING ENGINEERING FIRE PLANNING U/M ' WATER PLAN CHECK#: CB920865 PERMIT#: CB920865 PROJECT NAME: 2638 SF + 661 SF GARAGE PLAN 4 PHASE 1 DATE: 04/28/93 PERMIT TYPE: SFD ADDRESS: 2817 AVENIDA VALERA CONTACT PERSON/PHONE#: ALLISON @ FIELDSTONE/438-0468 SEWER DIST: LC WATER DIST: CA DATE INSPECTED: *-a63 APPROVED - / DISAPPROVED - INSPECTED BY: INSPECTED DATE BY: INSPECTED : APPROVED DISAPPROVED - INSPECTED DATE BY: INSPECTED: APPROVED - DISAPPROVED - c FINAL BUILDING INSPECTION RFrcl\mn ADD 3 q iQQq .I DEPT: BUILDING ENGINEERING 2 FIRE PLANNING U/M WATER PLAN CHECK#: CB920865 DATE: 04/28/93 PERMIT#: CB920865 PERMIT TYPE: SFD PROJECT NAME: 2638 SF + 661 SF GARAGE PLAN 4 PHASE 1 ADDRESS: 2817 AVENIDA VALERA CONTACT PERSON/PHONE#: ALLISON @ FIELDSTONE/438-0468 SEWER DIST: LC WATER DIST: CA INSPECTED DATE BY: e.%&& INSPECTED : 7,/,23/9, APPROVED & DISAPPROVED - INSPECTED DATE BY: INSPECTED: APPROVED - DISAPPROVED - INSPECTED DATE BY: INSPECTED : APPROVED - DISAPPROVED - CITY OF CARLSBAD INSPECTION REQUEST d * PERMIT# CB920865 FOR 05/10/93 INSPECTOR AREA PY DESCRIPTION: 2638 SF + 661 SF GARAGE PLAN 4 PLANCK# CB920865 TYPE: SFD CONSTR. TYPE VN JOB ADDRESS: 2817 AVENIDA VALERA STE: LOT: 129 APPLICANT: FIELDSTONE/LA COSTA ASSOC. PHONE: 619 546-8226 PHASE 1 OCC GRP R3/H1 CONTRACTOR: PHONE: OWNER: PHONE: REMARKS : BJN/ALLISON/4 3 8-04 68 INSPECTOR SPECIAL INSTRUCT: TOTAL TIME: CD LVL DESCRIPTION ACT COMMENTS 19 ST 29 PL 39 EL 49 ME -- -- -- DATE 030893 030493 030493 022493 022293 021793 021093 020993 020893 020393 020293 010593 101692 100592 Final Structural Final Plumbing Final Electrical Final Mechanical ***** INSPECTION HISTORY ***** DESCRIPTION Gas/Test/Repairs Exterior Lath/Drywall Interior Lath/Drywall Insulation Rough Combo Rough Combo Rough/Topout Rough/Topout Rough/Topout Shear Panels/HD's Shear Panels/HD's Roof /Reroof Ftg/Foundation/Piers Underground/Under Floor ACT INSP COMMENTS AP PY AP PY AP PY AP PY AP PY co PY AP PY NR PY NR PY NS PY AP PY AP MP AP MP AP HP EXT ONLY OK TO WRAP . CITY OF CARLSBAD NOTICE BUILDING DEPARTMENT - 438-3550 2075 LAS PALMAS DRIVE PERMIT NO. I -A i Li I FOR INSPECTION CALL 436-3101. RE-INSPECIION FEE DUE? 0 YES ... . .. . .. __ . . . .. . . ___ -. . .. .. . __ C)N!JFtI Ct? l.l?r! ,- r 1 .!n?,ll FAIRWAYS - PHASE I -__._.__I_ --~ .- ~~~~I*;I~~,I.~A**~ ,{I ,t'~ .r.a.fir I. ' ,) !-.~sir;~~ <?~?F:IG t: 017 MFGI4. NELSON & SLO9N CONCRETE ___ L2500 _____ DESCPIRF. .,!A 7':. I*.*!" c-5, 1s''. DC-AIR GRACF b UCGD.. <VVCLD-WOD. ElC.1 7895 Convoy Court San Diego, California 921 1 I PROFESSIONAL REGISTERED INSPECTIONS, INC. Phone 292-06' ._____ AWCIJITECT BERKUS GROUP JEM 111 EWGIttEER GEYERAL CONTRACTOR FIELDSTONE COMPANY CONTR. DOING REPORTED WORK 1/2" @, 7 STRAND, 270 KSI CABLE, MIX #6525, MUELLER LEWIS CONCRETE LAB. RECEIVING h TESTING CONSTR. MAT.:. SAhlPLES GAUGE #C826, GAUGE dC8105 INSP'N. DATE - P.R.I., INC. ---.---I- -- . - - - L3CATIONS OF WORK INSPECTED. TEST SAMPLES TAKEN, WORK REJECTED. JOB PROBLEMS. PROGRESS, REMARKS. ETC. IYCLLJDES lNFORh4ATlON ABOIJT -AMOUNTS OF MATERIAL PLACED OR VIORK PERFORMED: NUh4EER. TYPE. b IDE'I7.'IO'S. Or TEST 5AMPI.FS TAKEN. STRIJCT. CO'INECTIONS IWELDSVADE, H.T. BOLTS TOROUEDI CHECKEO; ETC. The post tension concrete work requiring special inspection was, to the best of my knowledge, in conformance with the approved plans and specifications and the applicable workmanship provisions Lot i12 i13 84 f5 11 6 i/ 7 il 8 i/ 9 810 ill 1 812 #13 #14 #15 #16 #17 of the Uniform Building Code, #3 thru 11. 3203 Sitio Rosalia 3207 Sitio Rosalia 3212 Sitio Rosalia 3208 Sitio Rosalia 3204 Sitio Rosalia 2808 Avenida Valera 2810 Avenida Valera 2812 Avenida Valera 2814 Avenida Valera 2816 Avenida Valera 2818 Avenida Valera 2820 Avenida Valera 2822 Avenida Valera 2826 Avenida Valera 2828 Avenida Valera 2830 Avenida Valera CB920-840 CB920-848 CB920-855 CB 9 20-85 9 CB920-849 CB920-841 CB9 20-83 6 CB9 20- 8 60 CB920-850 CB920-86 1 CB920-843 CB920-837 CB920-862 CB920-85 1 CB 9 20-8 63 CB920-864 1988 Edition. Inspection reports Lot 8109 2825 Vista Mariana CB920-839 #llO 2823 Vista Mariana CB920-866 8111 2821 Vista Mariana CB920-844 8112 2817 Vista Mariana CB920-854 f113 2815 Vista Mariana CB920-834 8114 2811 Vista Mariana CB920-857 #115 2809 Vista Mariana CB920-846 8116 2807 Vista Mariana CB920-858 #117 2805 Vista Mariana CB920-835 f118 2803 Vista Mariana CB920-847 8126 2811 Avenida Valera CB920-845 #127 2813 Avenida Valera CB920-853 t128 2815 Avenida Valera CB920-838 ,8129 "2817 Avenida Valera CB920-865 8130 2819 Avenida Valera CB920-852 28 Day Compression test that did not reach the required PSI Lot 83 - 2940 - 45 Days t6 - 2970 - 60 Days Remaining lots did meet required PSI. //r 284s. . DALE REGLI REGISTERED INSPFC -3F 4/12/93 280 DATE OF REPOWT 7cZ 5-E" .:-.,,SF 7895 Convoy Court PROFESSIONAL REGISTERED INSPECTIONS. INC. San Diego, California 92111 , Phone 292-066 FOR WEEK 0 ENDINQ ON .... flk!~..~~ ............. ~ ld INSPECTORS WEEKLY REPORT -#- 7 I FORCED GYPSUM 0 OTHER RLMARUS, ETC. E. C IDENT. NO’S. 1 SIGNAT~I(’&~F REGJS+ERED INSPECTOR . 1,’ DATE OF REPORT REGISTER NUMBER . . ... PROFESSIONAL REGISTEREI! INSPECTIONS, INC. 7895 Convoy Court #lS Ssn Diego, Ca. 92111 JQB NQ.: 401 1 **/O ............................................................................. .JOB A@DRESS: P.VENIE.4 VALEFA ARCHITECT: LriRIMAR & i3.A.SE JOB NAME: FAIRWAY 5 ENGINEER: JEM 111 PLAN FILE: INSPECTIQN REPQRT INSPECT@R : 11/09/92? : 280 @ATE REGISTER 1) .. .. PROFESSIONAL REGISTER INSPECTIONS, INC, 7895 Convoy Court #l5 San Diego, Ca. 92111 JOB NO.: 4911 JOB: FAT RWAY S ADD RE SS : 2017 AVENIDA VALERA OWNER: F I E L D S TON E CON PAN Y CONTRACTOR: MUELLER LEWIS CONCRETE CLIENT: MUELLER LEWIS CQNCRETE ENGINEER: JEM 111 ARCHITECT: BERKUS GROUP BLDG AUTH: CITY OF CARLSBAD INSPECTOR : JEFFREY GAY LER PERMIT NO,: CB92-0865 PLAN FILE: FIELD SAMPLE OF: CQNCRETE LOCATION @F SPECIMEN IN *JOB OR STRUCTURE: LOT +%*$F’ MIX NO.: 6525 MADE BY: JEFFREY GAYLER PROPORTIONS: SLUMP: 5 ” ADMIXTURE: DATE UADE: 10/21/92 TYPE OF CEMENT: I1 DATE RECEIVE@: 10/22/92 CONC. SUPP,LIER: NELSON & SLOAN SOURCE OF ROCK: TICKET NO.: r, 04.3 5 3 INSPECTOR SIGN: LABORATORY TEST DATA 7 DAYS lQ @AYS 28 DAYS 20 DAYS SPECIMEN MARKINGS: 92854 92055 92058 DATE TESTED: 10/31 11/18 11/18 AREA-SQ.IN.: 28 28 28.28 28.28 ULTIMATE LOAD-LBS: 58500 UNIT STRESS-LBS: e : 2070 a b SPECIFIED STRENGTH AT 28 @AYS-PSI: DISTRIBUTION: MUELLER LEWIS CONCRETE FIELOSTONE COMPANY CITY OF CARLSBAO JEM 111 2500 FOUNDATION OBSERVATION REPORT FOUNDATION LOCATION (if not entire building) 0 ADDITIONAL OBSERVATION REQUIRED PERMIT NO.: PLAN FILE NO.: I I SuBsTAKllAL CONFORMANCE a PURPOSE OF OBSERVATION: Ei ,p 0 0 Verify soil conditions exposed are similar to those anticipated. Verify footing excavations extend to minimum depth recommended in soil report. Verify foundation reinforcement complies with minimum recommended in soil report. Verify slab reinforcement, sand bedding and moisture barrier comply with minimum recommended in soil report. - 0 Other: a ;, _' f /> f :-/I jdl, I' I' /- 0 APPLICABLE SOIL REPORT: TITLE: j 0 SOIL REPORT RECOMMENDATIONS BASED ON *, / &,.. 7 /,, ry ; .'CB /d,,d- I i./I (3 f DA~: T~.~ 24, OL v @ Expansion Condition; 0 VERY LOW 0 LOW KMJ3DIUM "IGH 0 VERY HIGH B FillGeometry 0 Other: Footing Depth: B 12I"Es jX18INcHEs 024I"ES OTHER: Footing Reinforcement: 0 NO. 4 T&B 0 ZN0.4 T&B 0 NO5 T&B OTHER: 9T Interior Slab Reinforcement: 0 6x610/10 0 6x66/6 0 NO. 3 Q 24 INCHES ' 0 No. 3 Q 18 INCHES Slab Bedding Material and Thickness: Foundation Width: If yes, identify and describe: 0 MINIMUM FOUNDATION RECOMMENDATION Vapor Barrier: 0 FOUNDATION PLAN REVIEWED: YES0 NOW 0 OB ERVATIONS: dsubstantial cOnsOrmance with Soil Report (see "Purpose of Observation"). 0 Substantial conhnance with Foundation Plans. 0 COMMENTS: NOTE: IT IS ASSUMED THAT ALL FOOTLNG EXCAVATIONS WILL BE CLEANED OF LOOSE MATERIAL PRIOR TO PLACING CONCRETE AND THAT THE SOIL M0IS"RE CONTENT WILL BE? MAINTAINED. __ FIELD COPIES To GEOCON M-AT%VE PROFESSIONAL REGISTER INSPECTIONS, INC, 7895 Convoy Court #I5 San Diego, Ca. 92111 JOB NO.: 4911 JOB: ADDRESS : OWNER: CLIENT: ARCHITECT : INSPECTOR: FIELD SAMPLE OF: FAIRWAYS 28 17 AVENIQA YALERA FIELESTCINE COMPANY CONTRACTOR: MVELLER LEWIS CONCRETE MUELLER LEWIS CONCRETE ENGINEER: JEM I11 EERKUS GROUP BLDG AUTH: CITY !2F CARLSBAD *JEFFREV GAYLER PERMIT NO.: CB92-0865 PLAN FILE: CCINCRETE MIX N9.Z 6525 PROPORTIONS: ADMIXTURE: TYPE OF CEMENT: I1 LOCATION OF SPECIMEN IN JOB OR STRUCTURE: LOT XI29 UADE BY: JEFFREY GAYLER SLUMP: 5 I' DATE MADE: 10/2 1/92 DATE RECEIVED: 10/22/92 CONC. SUPRLIER: NELSON & SLOAN SOURCE OF ROCK: TICKET NO.: 4 04 3 5 3 INSPECTOR SIGN: LABORATORV TEST DATA 7 DAYS 10 DAYS 28 @AYS 28 RAYS SPECIMEN MARKINGS: 92854 92855 92856 @ATE TESTED: 10/3 1 11/18 11/18 AREA-SQ.IN.: 28 L 28 28 28 28.28 ULTIMATE LOAD-LBS: UNIT STRESS-LBS: 0 SPECIFIED STRENGTH AT 28 DAYS-PSI: DISTRIBUTION: MMELLER LEWIS CONCRETE FIELOSTQNE COMPANY JEM I11 CITY OF CARLSBAO 58500 83000 81500 : 2070 : 2940 : 2880 2500 ENGINEER