Loading...
HomeMy WebLinkAbout2819 LOKER AVE E; ; CB021383; Permit07-02-2002 i I { ' ! ) City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Commercial/Industrial Permit Permit No: Building Inspection Request Line (760) 602-2725 CB021383 Job Address: 2819 LOKER AV EAST CBAD Permit Type: Tl Sub Type: Parcel No: 2090830700 Lot#: Valuation: $53,760.00 Construction Type: Occupancy Group: Reference #: Project Title: ACUSHNET COMPANY-Tl 1792 SF COMM 0 NEW Status: Applied: Entered By: Plan Approved: Issued: Inspect Area: ISSUED 05/07/2002 JM 07/02/2002 07/02/2002 Applicant: Owner: DBML INC 814 DODSWORTH COVINA CA 91724 616 966-8666 Total Fees: Building Permit $2,560.61 Add'I Building Permit Fee Plan Check Add'I Plan Check Fee Plan Check Discount Strong Motion Fee Park Fee LFM Fee Bridge Fee BTD #2 Fee BTD #3 Fee Renewal Fee Add'I Renewal Fee Other Building Fee Pot. Water Con. Fee Meter Size Add'I Pot. Water Con. Fee Reel. Water Con. Fee 0536 07/02/02 0002 01 02 Total Payments To Date: $240.15 Balance Due: $2,320.46 $369.46 $0.00 $240.15 $0.00 $0.00 $11.29 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 Meter Size Add'I Reel. Water Con. Fee Meter Fee SDCWAFee CFO Payoff Fee PFF PFF (CFO Fund) License Tax License Tax (CFO Fund) Traffic Impact Fee Traffic Impact (CFO Fund) PLUMBING TOTAL ELECTRICAL TOTAL MECHANICAL TOTAL Master Drainage Fee Sewer Fee Redev Parking Fee Additional Fees TOTAL PERMIT FEES $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $562.00 $0.00 $0.00 $20.00 $24.00 $0.00 $1,333.71 $0.00 $0.00 $2,560.61 Clearance: ------ NOTICE: Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your rightto protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which ou have reviousl been iven a NOTICE similar to this or as to which the statute of limitations has reviousl otherwise ex ired. 2320~46 J~b405 PERMIT APPLICATION CITY OF CAl3-LSBAD BUILDING DEPARTMENT 1635 Faraday~.,_ Carl~~d, CA 92008 ~ Plan Ck. Depos._.it.-='i>-----"""-''"""'--"-:-"~ Validated By__.._,_ ...... _,_ __ __,,,....,...,... _ _,_ Date ___________ '--"'-4---=--- Address (include Bldg/Suite #) Business Name (at this address) Legal Description Total # of units Assessor's Parcel # Existing Use SQ. FT. /77'/4 #of Stories I lfi,~CW,07/02 000t fllBathr~~s CGP 240-15 State/Zip Telephone# Fax# i?;; . \o1. ~) q \ob-~(o(ob Telephone# , ', ' ' , ~, Name Address City State/Zip Telephone# [5 ... QQ,t,IJRJ.\PJQ.B:;wo_MJ?,~J\IY'i'iiAME, ... , ..•. "'~ . ,,· ... ., .... · ... ·• (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law [Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code) or that he is exempt therefrom, and the basis for the alleged exem tion. Any violation of Section 7031.5 b any applicant for a permit subjects the ap licant to a civil penalty of not more than five hundred dollars [$5001). D G --. o 0 \.o v, na , 3 1 to<o-.,,Cdo'=, Name State License # _i'--'· ,_YJ-"--'VJ'-'f.,_t\__.-:\---'· ,___ Address License Class ---={3~-_\ _____ _ City State/Zip Telephone# City Business License # ) 2 QCf3 C, °I e)C Designer Name Address State License# _________ _ ,9, .. WPf!.~E.1\$~ C,Qr;;:PEN1ATJ9N .·, . . . , :_ ~. ~.. '" . . ... City State/Zip Telephone _I i"2-oe:J_ 3 Workers' Compensation Declaration: I hereby affirm under penalty of perjury one of the following declarations: D I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 1911 I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is irs'ued. My worker's cor;rp~nsation insur:iyarrier and policy number are: I I Insurance Company Sto.·\-e F\J n~ Policy No. 0 'I I, -11)/~f-IJ hxpiration Date \ _ \ _ o 3 ' (THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS ($1001 OR LESS) D CERTIFICATE OF EXEMPTION: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. WARNING: Failure ecure workers' compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred 100, 001 • t..o:HMlm!ilei:l!Sation, damages as provided for in Section 3706 of the Labor code, interest and attorney's fees. SIGNATURE:_i~~~~~~_::,,;:~~~~:::::=::::=::::____________ DATE 4....._I:., -~ ~ :i.::: :.o:wmta:,»y1.(og13.0,~Q.~~A11or,1:' . . . .. ... , . I hereby affirm that I am exempt from the Contractor's License Law for the following reason: D I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). D I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). D I am exempt under Section ______ Business and Professions Code for this reason: 1. I personally plan to provide the major labor and materials for construction of the proposed property improvement. D YES ONO 2. I (have / have not) signed an application for a building permit for the proposed work. 3. I have contracted with the following person (firm) to provide the proposed construction (include name / address / phone number / contractors license number): 4. I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone number/ contractors license number): _____________________________________________ _ 5. I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone number / type of work): _______________________________________________________ _ PROPERTY OWNER SIGNATURE _____________________ _ DATE -----------)qqlytfi,L$,:_e;il;Hl!i '$;9TiQiY, FQflfiQN!:R~SIP/flY:TfAL 'B!Jll:,DiN~ <PE!\Mll:$J>NL'( · . Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? D YES ~ NO Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? D YES JG NO Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? 0 YES ~ NO IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. ~J:::Zqg-Jl~Jfl\lCTlc;>N:t,.f;!:,!p!N<? Aq'EN-:CY ··::~.: .: . : : ' •:.:::. ', ' '"' .: .... ' I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097(i) Civil Code). LENDER'S NAME _____________ _ ~-Al'f~,lCA.1'\l'.tC;RJIF,~c~;nqrii: : .•... :,., 'i,, ,·, ... I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all City ordinances and State laws relating to building construction. I hereby authorize representatives of the Cit\,' of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: An OSHA permit is required for excavations over 5'0" deep and demolition or construction of structures over 3 stories in height. EXPIRATION: Every permit issued by the building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is not com ed within 180 days from the date of such permit or if the building or work authorized by such permit is suspended or abandoned at any time after the work is comm ced or a ~eriod of 180 days (Section 106.4.4 Uniform Building Code). APPLICANT'S SIGNATURE _JL._,,L.'...!~~::::-::::::::>~/j~__!'L...p·:=:•-~=:::::::__ ______ _ DATE s-C::, .... IJ- WHITE: File YELLOW: Applicant PINK: Finance F-r~[§lfilg~ City of Carlsbad Bldg Inspection Request------ For: 08/28/2002 Permit# CB021383 Title: ACUSHNET COMPANY-Tl 1792 SF Description: Type: Tl Sub Type: COMM Job Address: 2819 LOKER AV EAST Suite: Lot O Location: APPLICANT DBML INC Owner: Remarks: OR SCOTT ROBBINS 818-612-7046 Total Time: CD Description Act Comments 19 Final Structural ( 29 Final Plumbing 39 Final Electrical 49 Final Mechanical -- Associated PCRs/CVs PCR00045 ISSUED PCR01155 ISSUED PCR99120 EXPIRED PCR99295 ISSUED lnsQection History: Date Description Act lnsp Comments 08/14/2002 84 Rough Combo AP PD CEILING 07/25/2002 14 Frame/Steel/Bolting/Welding AP PD 07/25/2002 17 Interior Lath/Drywall AP PD 07/25/2002 34 Rough Electric AP PD WALLS Inspector Assignment: PD --- Phone: 8186127045 lnspe#L Requested By: DAVE MENTALE Entered By: GIOVANNA EsGi I Corporation 'l.n Partnersfiip witfi (jovemmentfor '13uifaing Safetg DATE: June 26, 2002 JURISDICTION: Carlsbad PLAN CHECK NO.: 02-1383 PROJECT ADDRESS: 28,19 Loker Ave East PROJECT NAME: Acushnet -TI SET:11+ D~ANT ~ D PLAN REVIEWER D FILE D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. • The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified in the attached list are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. D The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. D The applicant's copy of the check list has been sent to: Dave Minto P.O. Box 5096, Covina, CA 91723 • Esgil Corporation staff did not advise the applicant that the plan check has been completed. D Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Dave Minto Telephone#: 626-966-8666 Date contacted: (by: ) Fax#: Mail Telephone Fax In Person D REMARKS: By: Bryan Zuppiger Enclosures: Esgil Corporation D GA D MB D EJ D PC LOG trnsmtl.dot 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858) 560-1468 + Fax (858) 560-1576 1. Applicant to provide a statement on the Title Sheet of the plans stating that this project shall comply with the 1998 edition of the California Building Code (Title 24 ), which adopts the 1997 UBC, UMC and UPC and the 1996 NEC. JUN.25.2002 11:13AM DBMC, Inc. General Building Contractors June 25, 2002 AT1N: Bryan Zuppiger JURISDICTION: City of Carlsbad PLAN CHECK NUMBER: 02-1383 PROJECT ADDRESS: 2819 Loker Ave. East PROJECT NAME: Acushnet N0.126 P.3 As per our discussion on June 24, 2002, we are providing the following information for your review. The HV AC, both new and existing will be running off the same panel, OPlD. EXISTING: 2 Ton unit fed from OPlD Spaces 022 & 023 20 Amp each. NEW: 2 Ton Unit fed from OPlD Spaces 026 & 027 20 Amp each. Panel OPlD is a 120v, 240v single phas~ panel. Disconnect at new unit is to be a 30 amp, MCAis 16.4 x 125%=20.5 amp necessary Conductor is #8 copper stranded with #12 Ground Length of run from Breaker, 100' Thank you, !J~d."J~~ David B. Minto PO Box 5096, 814 Dodsworth.Ave. Covina, CA 91723 (626) 966-8666 Office (626) 915-3746 FAX JUN.25.2002 11:14AM NO.126 P.4 _,..,.. _____ .,. __ ··------·-- E 't, .. EsGil Corporation 'l,n Partnersliip witli qovemment for '.Builaing Safety DATE: June 21, 2002 JURISDICTION: City of Carlsbad PLAN CHECK NO.: 02-1383 PROJECT ADDRESS: 2819 Loker Ave East PROJECT NAME: Acushnet -TI SET:11 (J,,,-A12-~ANT ~ D PLAN REVIEWER D FILE D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. D The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. IZ] The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. IZ] The applicant's copy of the check list has been sent to: Dave Minto P.O. Box 5096, Covina, CA 91723 D Esgil Corporation staff did not advise the applicant that the plan check has been completed. IZ] Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Dave Minto (-J· ~~ Telephone#: 626-966-8666 Date contacted: (e; f 2-1 l c 2 (by: Ce:-.. ) Fax #: Mail .....-'Telephone ..,....... Fax In Person D REMARKS: By: Bryan Zuppiger Esgil Corporation D GA D MB D EJ D PC Enclosures: 6/14/02 trnsmtl.dot 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858) 560-1468 + Fax (858) 560-1576 City of Carlsbad 02-1383 June 21, 2002 RECHECK PLAN CORRECTION LIST JURISDICTION: City of Carlsbad PROJECT ADDRESS: 2819 Loker Ave East DATE PLAN RECEIVED BY ESGIL CORPORATION: 6/14/02 REVIEWED BY: Bryan Zuppiger FOREWORD (PLEASE READ): PLAN CHECK NO.: 02-1383 SET: II DATE RECHECK COMPLETED: June 21, 2002 This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and disabled access. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department or other departments. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. A. Please make all corrections on the original tracings and submit two new sets of prints to: ESGIL CORPORATION. B. To facilitate rechecking, please identify, next to each item, the sheet of the plans upon which each correction on this sheet has been made and return this sheet with the revised plans. C. The following items have not been resolved from the previous plan reviews. The original correction number has been given for your reference. In case you did not keep a copy of the prior correction list, we have enclosed those pages containing the outstanding corrections. Please contact me if you have any questions regarding these items. D. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located on the plans. Have changes been made not resulting from this list? DYes DNo City of Carlsbad 02-1383 June 21, 2002 Please make all corrections on the original tracings, as requested in the correction list. Submit three sets of plans for commercial/industrial projects (two sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of pians and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. NOTE: The items listed below refer to the item numbers from previous list. These remaining items have not been adequately addressed. The notes in bold at the end of or contained within each item are to emphasize the remaining problem. 2. Provide a statement on the Title Sheet of the plans stating that this project shall comply with the 1998 edition of the California Building Code (Title 24 ), which adopts the 1997 UBC, UMC and UPC and the 1996 NEC. Unable to find on plans. 9. Please provide electrical load calculations. No response to correction. 10. Please provide panel schedules, indicate new and existing loads. No response to correction. 11. Please note on the plans "AC Cable is not allowed. NM cable is restricted (without City approval) to one and two family dwellings. Note on plans that an equipment ground conductor is to be installed in all flexible conduits". Per City of Carlsbad. No response to correction. 13. Please indicate on the plans the circuits feeding the new HVAC equipment. No response to correction. 15. Provide multiple switch lighting controls per Title 24, Part 6. No response to correction. 19. When alterations, structural repairs or modifications or additions are made to an existing building, that building, or portion of the building affected, is required to comply with all of the requirements for new buildings, per Section 1134B.2. No response to correction.These requirements apply as follows: a) The area of specific alteration, repair or addition must comply as "new" construction. b) A primary entrance to the building and the primary path of travel to the altered area, must be shown to comply with all accessibility features. City of Carlsbad 02-1383 June 21, 2002 c) Existing sanitary facilities that serve the remodeled area must be shown to comply with all accessibility features. 20. It is unclear from the plans if the restroom servicing the tenant improvement are disabled accessible, please provide a dimensioned restroom plans showing the restroom to be accessible compliant. No response to correction. 21. Show on the site plan the complying disabled accessible path of travel from the disabled accessible parking spaces to the primary entrance of the tenant space. No response to correction. To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Bryan Zuppiger at Esgil Corporation. Thank you. ,1, EsGil Corporation In Partnership with Government for Building Safety DATE: 5/20/02 JURISDICTION: City of Carlsbad PLAN CHECK NO.: 02-1383 PROJECT ADDRESS: 2819 Loker Ave East PROJECT NAME: Acushnet -TI SET:I D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. D The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. tz:I The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. tz:I The applicant's copy of the check list has been sent to: Dave Minto P.O. Box 5096, Covina, CA 91723 D Esgil Corporation staff did not advise the applicant that the plan check has been completed. tz:I Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Dave Minto Telephone#: 626-966-8666 Datecontacted:5/:2°/D.l(by: /CA) Fax #:(CPzc.)g,s.J1'f~- MaiL--,Telephone~ Fax / In Person D REMARKS: By: Doug Moody Esgil Corporation D GA D MB D EJ D PC Enclosures: 5/9/02 trnsmtl.dot 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858) 560-1468 + Fax (858) 560-1576 City of Carlsbad 02-1383 5/20/02 PLAN REVIEW CORRECTION LIST TENANT IMPROVEMENTS PLAN CHECK NO.: 02-1383 OCCUPANCY: B/Fl TYPE OF CONSTRUCTION: Unknown ALLOWABLE FLOOR AREA: SPRINKLERS?: Unknown REMARKS: DATE PLANS RECEIVED BY JURISDICTION: 5/7/02 DATE INITIAL PLAN REVIEW COMPLETED: 5/20/02 FOREWORD (PLEASE READ): JURISDICTION: City of Carlsbad USE: Office ACTUAL AREA: 1801 sf STORIES: 1 HEIGHT: OCCUPANT LOAD: 18 DATE PLANS RECEIVED BY ESGIL CORPORATION: 5/9/02 PLAN REVIEWER: Doug Moody This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Code sections cited are based on the 1997 UBC. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans. T_ENANT IMPROVEMENTS WITHOUT SPECIFIC ENERGY DATA OR POLICY SUPPLEMENTS (1997UBC) tiforw.dot City of Carlsbad 02-1383 5/20/02 Please make all corrections on the original tracings, as requested in the correction list. Submit three sets of plans for commercial/industrial projects (two sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. Generally the plans are incomplete and a thorough plan check can not be done, the following list is a general list only and corrections may follow. 1. Each sheet of the plans must be signed by the person responsible for their preparation, even though there are no structural changes. Business and Professions Code. 2. Provide a statement on the Title Sheet of the plans stating that this project shall comply with the 1998 edition of the California Building Code (Title 24 ), which adopts the 1997 USC, UMC and UPC and the 1996 NEC. 3. On the first sheet of the plans indicate: • The floor area of the remodeled area, • Type of construction of the existing building, • Sprinklers: Yes or No • Present and proposed occupancy classifications of the remodel area, • The occupant load of the remodel area(s). 4. Provide· a note on the site plan indicating the previous use of the tenant space or building being remodeled. Section 106.3.3. 5. Identify existing walls to be removed, existing walls to remain and proposed new walls. Identify bearing walls, non-bearing walls, and shear walls. 6. Please revise the section view of all new interior partitions. Show: a) Type, size and spacing of studs. Indicate gauge for metal studs. Specify manufacturer and approval number or indicate "to be ICBO approved". b) Method of attaching top and bottom plates to structure. Indicate the type, size and gauge of studs used for lateral bracing. City of Carlsbad 02-1383 5/20/02 c) d) Wall sheathing material and details of attachment (size and spacing of fasteners). Show height of partition and suspended ceiling, and height from floor to roof framing or floor framing. 7. Note on plan that suspended ceilings shall comply with UBC Tables 25-A, 16-0 and 16-B. 8. Specify lever-type hardware for passage doors on floors accessible to the disabled. Title 24. 9. Please provide electrical load calculations. 10. Please provide panel schedules, indicate new and existing loads. 11. Please note on the plans "AC Cable is not allowed. NM cable is restricted (without City approval) to one and two family dwellings. Note on plans that an equipment ground conductor is to be installed in all flexible conduits". Per City of Carlsbad. 12. Please attach the City of Carlsbad Policies and Procedures for Roof Mounted Equipment to the plans. 13. Please indicate on the plans the circuits feeding the new HVAC equipment. 14. Please revise the plans to show a GFCI protected service receptacle with 25' of the new HP-1. 15. Provide multiple switch lighting controls per Title 24; Part 6. 16. The completed and signed ENV-1, L TG-1, and MECH-1 forms must be imprinted on the plans. 17. On the plans clearly show the wall and roof insulation locations, thickness, and · R-values, as per the energy design. 18. Please complete the mandatory measure checklists imprinted on the plans. 19. When alterations, structural repairs or modifications or additions are made to an existing building, that building, or portion of the building affected, is required to comply with all of the requirements for new buildings, per Section 1134B.2. These requirements apply as follows: a) The area of specific alteration, repair or addition must comply as "new" construction. b) A primary entrance to the building and the primary path of travel to the altered area, must be shown to comply with all accessibility features. City of Carlsbad 02-1383 5/20/02 c) Existing sanitary facilities that seNe the remodeled area must be shown to comply with all accessibility features. 20. It is unclear from the plans if the restroom seNicing the tenant improvement are disabled accessible, please provide a dimensioned restroom plans showing the restroom to be accessible compliant. 21. Show on the site plan the complying disabled accessible path of travel from the disabled accessible parking spaces to the primary entrance of the tenant space. To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. . Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please indicate: Yes D No D The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Doug Moody at Esgil Corporation. Thank you. CITY OF CARLSBAD POLICIES AND PROCEDURE · :UMBER: 80-6 SUBJECT: ROOF MOUNTED EQUIPMENT EFFECTIVE: 5/1 /92 SECTION: BUILDING DEPARTMENT SUPERSEDES: 80-6(9/10/80) 80-6(5/01 /81 l PURPOSE: PROVIDE INSTALLATION STANDARDS FOR ALL ROOF MOUNTEDP EQUIPMENT AND PENETRATIONS ON COMMERCIAL AND INDUSTRIAL BUILDINGS. INTENT: POLICY: A. Maintain roof integrity. B. Prevent hazardous condition to firemen who must fight fire on the roof. C. Provide an installation that is aesthetically sensitive to the building and the adjoining properties. 1. All equipment shall be concealed from view and the design* shall meet the approval of the Planning Department. 2. All equipment shall be ·specifically designed and approved for exterior use and shall be approved by the City of Carlsbad Building Department. 3. All roof mounted equipment shall be on a platform which shall be an integral part of the roof--flashed and waterproofed. When a screen is· approved, it. shall have as few roof connections as possible and be structurally adequate. 4. All electrica[, plumbing, mechanical duct work and related piping shall be inside the building and r;iot on the roof. All connections related to equipment shall be made in the same roof opening on the platform or have the prior approval from the building official. 5. Sewer vents shall be brought to one main vent below the roof and have one penetration where restrooms or other plumbing fixtures are back to back or in the general proximity. Air exhaust fans and other equipment shall be within the building and use the same roof opening where restrooms and other equip.ment are back to back or in g~neral prox,imity. 6. Existing buildings and equipment, remodel or replacement, shall meet .thE}_-C?bove regulations or shall have the prior approval from _the building official. 7. Where new equipment is installed, unused or abahdoned equipment, including all roof mounted piping, electr_ic-al, mechanical, duct, ~n.d oth~r related appurtenances shall be removed from roof and unused openings properly sealed -to maintain roof integrity. · · *The architect should, through design, conceal the heating/ AC unit ~nd other equipment whether they are pn the roof or elsewhere. · initiated By: C City of Carlsbad 02-1383 5/20/02 VALUATION AND PLAN CHECK FEE JURISDICTION: City of Carlsbad PREPARED BY: Doug Moody PLAN CHECK NO.: 02-1383 DATE: 5/20/02 BUILDING ADDRESS: 2819 Loker Ave East BUILDING OCCUPANCY: B/Fl TYPE OF CONSTRUCTION: Unknown BUILDING AREA Valuation Reg. VALUE PORTION ( Sq. Ft.) Multiplier Mod. Tl 1801 City Valuation . Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code cb By Ordinance 1994 UBC Building Permit Fee I • I 1994 UBC Plan Check Fee I • I Type of Review: 0 Complete Review D Structural Only D Repetitive Fee =8 Repeats Comments: D Other D . Hourly .,__ ____ I Hour* Esgil Plan Review Fee ($) 53,760 53,760 $360.461 $234.301 $201.861 Sheet 1 of 1 macvalue.doc V Ocwe.-M ~vv-l-o City of Carlsbad •@O 1 ,a;:z., k:t-+11-#i U· 1 • 1144 a I U·J BUILDING PLANCHECK CHECKLIST I DATE: PLANCHECK NO.: BUILDING ADDRESS: ' ~{9 LAk..e..r Ave . ~~J-· CB 0:J-(3£:3 PROJECT DESCRIPTION: ASSESSOR'S PARCEL NUMBER: ,, EST. VALUE: 53 7 ~ t) i ENGINEERING DEPARTMENT APPROVAL DENIAL The item you have submitted for review has been approved. The approval is based on plans, information and/or specifications provided in your submittal; therefore any changes to these items after this date, including field modifications, must be reviewed by this office to insure continued conformance with applicable codes. Please review carefully all comments attached, as failure to comply with instructions in this report can result in suspension of permit to build. D A Right-of-Way permit is required prior to construction of the following improvements: Please se /t attached report of deficiencies marked · D.iake necessary corrections to plans or spe 1fi ation for compliance with applicable codes a st ards. Submit corrected plans and/or specifications to this office for review. By: Date: By: Date: ORIZATION TO ISSUE BUILDING PERMIT: By: D Dedication Application D Dedication Checklist D Improvement Application D Improvement Checklist D Future Improvement Agreement D Grading Permit Application D Grading Submittal Checklist D Right-of-Way Permit Application D Right-of-Way Permit Submittal Checklist and Information Sheet D Sewer Fee Information Sheet Date: 7~tf)--- Name: ENGINEERING DEPT. CONTACT PERSON Karen ~ City of Carlsbad Address: 1635 Faraday Avenue, Carlsbad, CA 92008 Phone: (760) 602-2775 CFO INFORMATION Parcel Map No: Lots: Recordation: Carlsbad Tract: H:1Deve10Jiln6a.lii;Jmasao~citiltstlllliilllilifi:l'1.tl'!chGaislsla.ad, CA 920081-7314 • (760) 602-2720 • FAX (760) 602.£5.oa * C, I D D BUILDING PLANCHECK CHECKLIST SITE PLAN 1. Provide a f1:1_lly dimensioned site pl?n ~r wn to scale. Show: North Arrow . Right-of-Way Width & Adjacent Streets xisting & Proposed Structures . Driveway widths It;( xisting Street Improvements ?.5 Existing or proposed sewer lateral . ;;;, Property Lines )( Existing or proposed water service )?. Easements / Existing or proposed irrigation .service 2. Show on site plan: If Drainage Patterns / .. 1. Building pad surface drainage must maintain a minimum slope of one percent towards an adjoining street or an approved drainage course. 2. ADD THE FOLLOWING NOTE: "Finish grade will provide a minimum positive drainage of 2% to swale 5' away from building." Jtf Existing & Proposed Slopes and Topography Y. Size, type, location, alignment of existing or proposed sewer and water service {s) that serves the project. Each unit requires a separate service, however, _ recond dwelling units and apartment complexes are an exception. !;Y. Sewer and water laterals should not be located within proposed driveways, per standards. 3. Include on title sheet: ~" Site address ~ Assessor's Parcel Number ~ Legal Description For commercial/industrial buildings and tenant improvement projects, include: total building square footage with the square footage for each different use, existing sewer permits showing square footage of different uses (manufacturing, warehouse, office, etc.) previously approved. EXISTING PERMIT NUMBER DESCRIPTION H:IWORD\DOCS\CHKLSnBulldlng Plancheck Cklst Fann (Generlc).doc 2 Rev. 7/14/00 __ _j ______ _ D D D D D D D D D BUILDING PLANCHECK CHECKLIST DISCRETIONARY APPROVAL COMPLIANCE 4a. Project does not comply with the following Engineering Conditions of approval for Project No .. _______________________ _ 4b. All conditions are in compliance. Date: _________ _ DEDICATION REQUIREMENTS 5. Dedication for all street Rights-of-Way adjacent to the building site and any storm drain or utility easements on the building site is required for all new buildings and for remodels with a value at or exceeding $15,000, pursuant to Carlsbad Municipal Code Section 18.40.030. Dedication required as follows: ________________ _ Dedication required. Please have a registered Civil Engineer or Land Surveyor prepare the appropriate legal description together with an 8 ½" x 11" plat map and submit with a title report. All ·easement documents must be approved and signed by owner(s) prior to issuance of Building Permit. Attached please find an application form and submittal checklist for the dedication process. Submit the completed application form with the required checklist items and fees to the Engineering Department in person. Applications will not be accept by mail or fax. Dedication completed by:____________ Date: ___ _ IMPROVEMENT REQUIREMENTS 6a. All needed public improvements upon and adjacent to the building site must be constructed at time of building construction whenever the value of the construction exceeds $75,000, pursuant to Carlsbad Municipal Code Section 18.40.040. Public improvements required as follows: ____________ _ Attached please find an application form and submittal checklist for the public improvement requirements. A registered Civil Engineer must prepare the appropriate improv~ment plan~ and submit them together with the requirements on the attached checklist to the Engineering Department through a separate plan check process. The completed application form and the requirements on the H:\WORDIOOCSICHKLSnBudding Plancheck Cklst Fann (RIDDLE· HARVEY 7-12-00).doc 3 Rev. 12126/86 D D D D D D D D D D D D D D D D D BUILDING PLANCHECK CHECKLIST checklist must be submitted in person. Applications by mail or fax are not accepted. Improvement plans must be approved, appropriate securities posted and fees paid prior to issuance of building permit. Improvement Plans signed by: _________ _ Date: ----- 6b. Construction of the public improvements may be deferred pursuant to Carlsbad Municipal Code Section 18.40. Please submit a recent property title report or current grant deed on the property and processing fee of $31 O so we may prepare the necessary Future Improvement Agreement. This agreement must be signed, notarized and approved by the City prior to issuance of a Building permit. Future public improvements required as follows: 6c. Enclosed please find your Future Improvement Agreement. Please return agreement signed and notarized to the Engineering Department. Future Improvement Agreement completed by: Date: 6d. No Public Improvements required. SPECIAL NOTE: Damaged or defective improvements found adjacent to building site must be repaired to the satisfaction of the City Inspector prior to occupancy. GRADING PERMIT REQUIREMENTS The conditions that invoke the need for a grading permit are found in Section 11.06.030 of the Municipal Code. 7a. Inadequate information available on Site Plan to make a determination on grading requirements. Include accurate grading quantities (cut, fill import, export). 7b. Grading Permit required. A separate grading plan prepared by a registered Civil Engineer must be submitted together with the completed application form attached. NOTE: The Grading Permit must be issued and rough grading approval obtained prior to issuance of a Building Permit. Grading· Inspector sign off by: Date: ---------- 7c. Graded Pad Certification required. (Note: Pad certification may be required even if a grading permit is not required.) H:IWORD\OOCS\CHKLSnBu11dmg Plancheck Cklst Form (Generic 7-14-00).doc 4 Rev. 7/14/00 D D D D r)I ,~ D D BUILDING PLANCHECK CHECKLIST 7d .No Grading Permit required. 7e. If grading is not required, write "No Grading" on plot plan. MISCELLANEOUS PERMITS 8. A RIGHT-OF-WAY PERMIT is required to do work in City Right-of-Way and/or private work adjacent to the public Right-of-Way. Types of work include, but are not limited to: street improvements, tree trimming, driveway construction, tying into public storm drain, sewer and water utilities. Right-of-Way permit required for: 9. INDUSTRIAL WASTE PERMIT If your facility is located in the City of Carlsqad sewer service area, you need to contact the Carlsbad Municipal Water District, located at 5950 El Camino Real, Carlsbad, CA 92008. District personnel can provide forms and assistance, and will check to see if your business enterprise is on the EWA Exempt List. You may telephone (760) 438-2722, extension 7153, for assistance. Industrial Waste permit accepted by: Date: 10. NPDES PERMIT Complies with the City's requirements of the National Pollutant Discharge Elimination System (NPDES) permit. The applicant shall provide best management practices to reduce surface pollutants to an acceptable level prior to discharge to sensitive areas. Plans for such improvements shall be approved by the City Engineer prior to issuance of grading or building permit, whichever occurs first. 11. J,< Required fees are attached -TB~ la ~o fees required WATER METER REVIEW 12a. Domestic (potable) Use Ensure that the meter proposed by the owner/developer is not oversized. Oversized meters are inaccurate during low-flow conditions. If it is oversized, for the life of the meter, the City will not accurately bill the owner for the water used. • All single family dwelling units received "standard" 1" service with 5/8" service. H:\WORDIDOCSICHKLS1'8ulldlng Plancheck Cklst Form (Generic).doc 5 Rev. 7114100 1ST D D D ,-J/ /Jr- BUILDING PLANCHECK CHECKLIST • If owner/developer proposes a size other than the "standard", then owner/developer must provide potable water demand calculations, which include total fixture counts and maximum water demand in gallons per minute {gpm). A typical fixture count and water demand worksheet is attached. Once the gpm is provided, check against the "meter sizing schedule" to verify the anticipated meter size for the unit. • Maximum service and meter size is a 2" service with a 2" meter. • If a developer is proposing a meter greater than 2", suggest the installation of multiple 2" services as needed to provide the anticipated demand. {manifolds are considered on case by case basis to limit multiple trenching into the street). 12b. Irrigation Use {where recycled water is not available) . All irrigation meters must be sized via irrigation calculations {in gpm) prior to approval. The developer must provide these calculations. Please follow these guidelines: 1. If the project is a newer development {newer than 1998), check the recent improvement plans and observe if the new irrigation service is reflected on the improvement sheets. If so, at the water meter station, the demand in gpm may be listed there. Irrigation services are listed with a circled "I", and potable water is typically a circled "W". The irrigation service should look like: STA 1+00 Install 2" service and 1.5: meter (estimated 100 gpm) 2. If the improvement plans do not list the irrigation meter and the service/meter will be installed via another instrument such as the building plans or grading plans (w/ a right of way permit of course), then the applicant must provide irrigation calculations for estimated worst-case irrigation demand (largest zone with the farthest reach). Typically, Larry Black has already reviewed this if landscape plans have been prepared, but the applicant must provide the calculations to you for your use. Once you have received a good example of irrigation calculations, keep a set for your reference. In general the calculations will include: • Hydraulic grade line • Elevation at point of connection (POC) • Pressure at POC in pounds per square inch (PSI) • Worse case zone (largest, farthest away from valve • Total Sprinkler heads listed (with gpm use per head) • Include a 10% residual pressure at point of conne9tion 3. In general, all major sloped areas of a subdivision/project are to be irrigated via separate irrigation meters (unless the project is only SFD with no HOA). As long as the project is located within the City recycled water H:\WORD\DOCSICHKLSnBulldlllg Plancllecf< Cklsl Form (GenerlcJ.doc 6 Rev. 7114/00 !r D D D DD BUILDING PLANCHECK CHECKLIST service boundary, the City intends on switching these irrigation services/meters to a new recycled water line in the future. 12c. Irrigation Use (where recycled water is available) 1. Recycled water meters are sized the same as the irrigation meter above. 2. If a project fronts a street with recycled water, then they should be connecting to this line to irrigate slopes within the development. For subdivisions, this should have been identified, and implemented on the improvement plans. Installing recycled water meters is a benefit for the applicant since they are exempt from paying the San Diego County Water Capacity fees. However, if they front a street which the recycled water is there, but is not live (sometimes they are charged with potable water until recycled water is available), then the applicant must pay _the San Diego Water Capacity Charge. If within three years, the recycled water line is charged with recycled water by CMWD, then the applicant can apply for a refund to the San Diego County Water Authority (SDCWA) for a refund. However, let the applicant know that we cannot guarantee the refund, and they must deal with the SDCWA for this. . H:IWORDIOOCS\CHKLST\Buildlng Piancheck Cl<lst Fonn (Generlc).doc 7 Rev. 7/14/00 ENGINEERING DEPARTMENT FEE CALCULATION WORKSHEET D Estimate based on unconfirmed information from applicant. X_ Calculation based on building plancheck plan submittal. Address: ;).!RLCJ UJ k~ Av,~ t_ • Bldg. Permit No. Ct& 0 d--~9!-3 Prepared by: 1~ Date: tc/-tf<fl--c:Fiecked by:--'-----Date: r I ----- EDU CALCULATIONS: List types and square footages for all uses. Types of Use: ~ Sq. Ft./Units: _______ EDU's: __ .;__,_u_· 3 __ Types of Use: _______ Sq. Ft/Units: EDU's: _____ _ ADT CALCULATIONS: List types and square footages for all uses. /)~ ~;:;_ .. Types of Use: vz;p= Sq. Ft./Units: _______ ADT's: _...;;c.,,.;..;:._, __ _ Types of Use: _______ Sq. Ft./Units: ADT's: _____ _ FEES REQUIRED: WITHIN CFO: ~~ES (no bridge & thoroughfare fee in District #1, reduced Traffic Impact Fee) D NO D 1. PARK-IN-LIEU FEE PARK AREA & #: __ _ FEE/UNIT:,____ X . NO. UNITS: __ _ M2. TRAFFIC IMPACT FEE p ADT's/UNITS: dd X FEE/ADT: $ =$. ____ _ =$-=-S--_l.P._,,;J__ /i7). BRIDGE AND THOROUGHFARE FEE (DIST. #1 v7 DIST. #2 __ DIST.#3 __ ) y ADT's/UNITS:.____ X FEE/ADT: -=e-· I' D 4. FACILITIES MANAGEMENT FEE ZONE: __ _ UNIT/SQ.FT.: ___ _ m5. SEWER FEE lV EDU's: ; &3 BENEFIT AREA: G, EDU's: ,{p'3 D 6. SEWER LATERAL ($2,500) D 7. DRAINAGE FEES PLDA. __ _ ACRES: ____ _ D 8. POTABLE WATER FEES X FEE/SQ.FT./UNIT: __ _ X X FEE/EDU: ~CJ/ 7' FEE/EDU: qg HIGH ___ /LOW __ X FEE/AC:, __ _ UNITS CODE CONNECTION FEE METER FEE SDCWAFEE 1 of 2 F:IFEE CALCULATION WORKSHEET.doc =$ ,_0- =$ __ -e---=--- =$ I , ;;. 11 ~ 1 7 1 =$ lei~ 7cf" =$, ___ _ =$__, ___ _ IRRIGATION Rev. 7/14/00 ENGINEERING DEPARTMENT FEE CALCULATION WORKSHEET D 9. RECLAIMED WATER FEES UNITS CODE CONNECTION FEE METER FEE II \.~ 71 TOTAL OF ABOVE FEES*:$ -tJ I~ ~ I ---i1"--------=--- *NOTE: This calculation sheet-is NOT a complete list of all fees which may be due. Dedications and Improvements may also be required with Building Permits. ~·-· 2 of 2 F:\FEE CALCULATION WORKSHEET.doc Rev. 7 /14/00 . · /rf)F ... ~ ' . 1,1q2 _:;-/j()(} ""-l~ A .~o .. ~ I'. 1 °!'l ~ f c!UJ ~ I ~· . I . • ~ . . . . )( 5- ·1.r- · .. ~?/\. /,7 Ci':J _; I ra-zJ· . :::.-, 1 ( '1 19 )-. ~ 57)7)() ::_ . ~ 3l, . I. ·-·~~ . :tt{?$ ' ' ~ ~ ~ ~ I\ -'\ ) "' 2 2 "* "' "' Cl 0 0 J J -::; --::s 1i' >, >, .a .a ~ N O') 'It 'It -"' -"' -"' 0 " " Cl) Q) Q) .c .c .c (.) (.) (.) C: C: C: .!!l "' "' a.. a: a: @DD PLANNING DEPARTMENT BUILDING PLAN CHECK REVIEW CHECKLIST Plan Check No. CB Oz.-I> {33 Address 2-6/ ct W/!d:JL At/t:r §ti ST Planner __ V-=---=a'-'-n-=LC4y-'--'n=c..c..:h ________ _ Phone (760) 602-4613 APN: ____________________________ _ Type of Project & Use: /JJl)uf c z;r;.: Net Project Density:_~.A4-=r--1/A-~_~D~U~/A---=C- Zoning: {? .;i;: General Plan: p.:z= Facilities Management Zone: __ .r __ _ CFO li_nfnV).).....# -Date of participation: Remaining net dev acres: --- C1rc1~ ---- (For non-residential development: Type of land used created by this permit: __ ~ _________________ ) Legend: ~ Item Complete ([J) Item Incomplete -Needs your action Environmental Review Required: YES NO .X: TYPE ---- DATE OF COMPLETION: -------- Compliance with conditions of approval? If not, state conditions which require action. Conditions of Approval: 'KJ D D Discretionary Action Required: YES __ NO J(__ TYPE ___ _ APPROVAL/RESO. NO. _____ DATE ___ _ PROJECT NO. --------- 0 THE R RELATED CASES: __________________ _ Compliance with conditions or approval? If not, state conditions which require action. Conditions of Approval: ------------------------ ,3J_ D D Coastal Zone Assessment/Compliance Project site located in Coastal Zone? YES NO A-- CA Coastal Commission Authority? YES NO If California Coastal Commission Authority: Contact them at -7575 Metropolitan Drive, Suite 103, San Diego CA 92108-4402; (619) 767-2370 Determine status (Coastal Permit Required or Exempt): Coastal Permit Determination Form already completed? YES NO If NO, complete Coastal Permit Determination Form now. Coastal Permit Determination Log #: Follow-Up Actions: 1) Stamp Building Plans as JI Exempt" or JI Coastal Permit Required" (at minimum Floor Plans) .. 2) Complete Coastal Permit Determination Log as needed. H:\ADMIN\COUNTER\BldgPlnchkRevChklst ~DD lnclusionary Housing Fee required: YES __ NO¼_ (Effective date of lnclusionary Housing Ordinance -May 21, 1993.) Data Entry Completed? YES __ NO __ (A/P/Ds, Activity Maintenance, enter CB#, tool bar, Screens, Housing Fees, Construct Housing Y /N, Enter Fee, UPDATE!) Site Plan: D D D 1. Provide a fully dimensional site plan drawn to scale. Show: North arrow, property lines, easements, existing and proposed structures, streets,· existing street improvements, right-of-way width, dimensional setbacks and existing topographical lines (including all side and rear yard slopes). )61 D D 2. Provide legal description of property and assessor's parcel number. Zoning: ~DD 1 . Setbacks: ~(()~ Front: Required Shown / II Interior Side: Required Shown v~y II-' op; Street Side: Required Shown Rear: Required Shown Top of slope: Required Shown ,Qg_ D D 2. Accessory structure setbacks: Front: Required ------r---Shown ------1 n t er i or Side: Required ------Shown ------Street Side: Required ------Shown ------Rear: Required --'------Shown ------- Structure separation: Required ---------Shown ------ @ D D 3. Lot Coverage: Required /~IL wc:>l> <;. JJ//4--Shown . ------ D D D 4. Height: Required ------Shown ------ 5. Parking: Spaces Required ~ .S-0 --=--=::--'----Shown ) .CS (breakdown by uses for commercial and industrial projects required) Residential Guest Spaces Required ______ Shown _____ _ Additional Comments r74f::laSS' f'A;vtD4L Altn,-1't.8t oF /JAf2.lu,.o6 .t:/JAc..BS. btibA1JJ,,¢(b Bv: /#tr CHfiPlvf:T 1/J 't.w1t-1::,1.A16 t/J'tr A¢ #ot= f:'/JAcJJ5. />Mtbr:JD. r PU:JArrr-.>'kot:J cow /JUA~ w 1"11-f ~toW/f a,, ?T/V 6 A/2.&4-~ 1!U§'N 1::5/fJ, , C¥="' got) ~t:Jr90 ~~"&tu 1116-J}C-UJru ~PW HPJV ~a wPth'"'nJb r1(:?C;(A,,J/L/Jt-0(52µ/j)N~T""" W/t.L 'fs&r .Sc_MWSJ) / -'f) c:,,J 'l-,4A/:I (!$ 0f.l.1TlP • OK TO ISS E AND ENTERED APPROVAL INTO COMPUTER (/.{K,vj__ DATE 7-l--0'2.... /JO C/-lkovcr 'f-t.l @.,I) .. H :\ADMI N\CO U NTER\BldgPlnchkRevChklst ~~~~~ ,~ ... ~ ,/ ·,: '.:: ; . ~:t~ i l:XIStlNG ADDED TOTAL 2W -2 + 25 44 8 ..... ~ ·=:;;.-....: ............. -===::;::-... .., ........... :f······.:,. •••• , ....... -:.·· ...... -:;,, ............. .:. ...... -:.'$,·::.:. ••• : ................ -:f·:, ••• :,.; ........... -:.·· ...... : •• • •.••.•••.• ·:······· .................. .:-···'-..:: ............. -: ... .$ ................... .:.··} ................... -:f: F~ FiEGlJl~T& l:Xl&TINGr TENANT U5E AREA FA~INGr Gff=ICE ll)OO 5.F. 4 WARl:I-IOUSE 2l)1b SJ=. 21 MANUFACTURING ~ ~ 5UB-TOTAL5 22,11b 5.1=. 25 ·········· ....••... •.-.; ... ·····••········ ........ ., ............................... ················ .. _. .................... -:················· ........... ················-........... ·-··· ••••••••• •• -::, ..................... •••• •••• ••••• ••• ·····:···· •• •••• •••• .. =::;,::=--.· ···::_ •• ••• ···.{· ...... • -:- TITLEl&T USE A~A f'AFc!<.ING Cff=ICE i8,e'O.:! ~t= 112. WAREI-OJSE: l., !>9S J!t J:. '-I , MANIJFAc~ "TS,441 &J=. I ca~-·~- eue-totAL& 32..~ TOTAL PAA1KI~ fiEQUlfED 3;.s-0 TOT AL PARKING PROVIDED *SOK I NOTe: ! tENANT SPACe WA5 ~YfOUSL Y A MANUFACTIJRJNG r '. FACILfTY FOR C~fUM GRA~ICS INC. ,,~ ,,>"-<", .... ,, .. r '''·'-··.w"''\., .... ,", .. ,,:·,.·, .......... ,,.§.'-:,,, .... w·,··'·\,.,. .. _,,,.,,,,,_..", .. ,,'''-.,,,.,, .. ,.f'-.,.,,",., .... •'1.:, •• w ... •'' •. •'\'-.."W·<:·''.f,.,,_.",.,,<• '.•._. ,.,,· J f I l' L ck. e.r ,4 v ~ £ d s <t- c_o,. l1b6& c.A- ,/ p L 60. C k .t::J:. 0 d-,... \ .3 u ·~ Carlsbad Fire Department 021383 1635 Faraday Ave. Carlsbad, CA 92008 Plan Review Requirements Category: Building Plan Reviewed by: Fire Prevention -t.,. (760) 602-4660 Date of Report: _0_51_09_12_0_0_2 _______ _ Name: / DAVE MINTO Address: PO Box 5096 City, State: Covina CA 91723 Plan Checker: Job#: 021383 ------- Job Name: Acushnet Bldg #: ------------------=-- Job Address: 2819 Loker Ste. or Bldg. No. [g] Approved D Approved Subject to D Incomplete Review FD Job# The item you have submitted for review has been approved. The approval is based on plans, information and / or specifications provided in your submittal; therefore any changes to these items after this date, including field modifications, must be reviewed by this office to insure continued conformance with applicable codes and standards. Please review carefully all comments attached as failure to comply with instructions in this report can result in suspension of permit to construct or install improvements. The item you have submitted for review has been approved subject to the attached conditions. The approval is based on plans, information and/or specifications provided in your submittal. Please review carefully all comments attached, as failure to comply with instructions in this report can result in suspension of permit to construct or install improvements. Please resubmit to this office the necessary plans and / or specifications required to indicate compliance with applicable codes and standards. The item you have submitted for review is incomplete. At this time, this office cannot adequately conduct a review to determine compliance with the applicable codes and / or standards. Please review carefully all comments attached. Please resubmit the necessary plans and/ or specifications to this office for review and approval. 1st 021383 2nd FD File# 3rd Other Agency ID ~ ~ ' ~ ~- ~ ~ t \J\. . rt ,. ~ rb _"It ;~ -~ ~ _.) ~ f', n-, tt '\ POOR QUALITY ORIGINAL S .. . " ,, ... . , ~ ,· . ,' :, ... •. . . . .•··. ~ . ~ ,... 0 :c I ·Z -I ~,,l\ ""'" I\ o•c ·i~ -:\-1 'fll\l• . -< I' I 6 I ~ .. ~ I ~,-. , I . ·--.... .. . ~ . WALL FRAMING DETAIL .. .. . . ,· . 0 01 5. (1) LAYER I/ '2.." TYPE "Xw GYP. BO. ,1 6. 3-5/e-X 25.,GA. AT. 24"' o.c. q2---r-c.t?..o· A--,-,-N,v-~«._ 7. FINISH PER NOTES ON PLi?\NS. 8. 1/4" DIA, SHOT PINS AT 32-. .. O,C. AND 12 ... FROM-ENDS, OPENINGS. 9. BOTTOM TRACK - 10.RUBBER TOP-SET BASE 11.EXIST. CONC. SLAB 13.OIAG. BRACE STUDS AT 48"O.C. ALTERNATE DIRECTION -TYP. C.M.C.= CHICAGO METALLIC CORP • I: \) ---. ~ .... ~-=,,==-·--.:. -" ·-· \.. .J n~ ,., .....___ ,; ~ s ':,. "~ ,. lt 0 I ---it) -• - \,.) q_ A ~ ~ 0 tq I I 0 N !:! • r·~. ) ~ • ·,j' L..., ~ I." • -- -• - lt en I .-cc '-- I· . ,,/ ,,/ ,,/' o;.., I ;-.. . ./" ./ 0 ~ .- .Y' / ,,/ 0 IC '7 r,o_g • ..O-.Ol ' .o-6 'b C) I b N / 15 ,/" -u: Ill w w / A: u /" -,-:-, --~. tt. l!il I' ... b w 0 ....... ... I / / /" U') I 1:--::-·-"."""'f'" 1 ~/ · 200 ... 20.0 'd 9t,ltS't6929t:Ol \t=, " 0 ~ ,.. ~ ' I t t I I I I ; ~----~ r--t---1>~tt--+--_L ___ x ·--· -----·-----J.-'1.'L.1,,:·i-+---1 r--H~I\ -+--1-J~ --. ···--jr---fHI><,>< -+---1 ., , 1J \. ---... -t-f1~--1 -~ i 'I i ~ • .. r--1----1-----l--~-+---·r----1---- ,. TITLE 24 REPORT Title 24 Report for: Acushnet Company-Warranty Repair/Eng. Lab 2819 Loker Avenue East Carlsbad, CA 92008 Project Designer: Report Prepared By: Steve Balderrama, CEPE Stueven Engineering Consultants 425 W. 5th Ave. Suite 103 Escondido, CA 92025 (760) 735-8577 Job Number: Date: 05/24/2002 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2001 Building Energy Efficiency Standards. This program developed by EnergySoft, LLC (415) 883-5900. EnergyPro 3.1 By EnergySoft Job Number: User Number: 3429 Cover Page Table of Contents TABLE OF CONTENTS Nonresidential Performance Title 24 Forms Form ENV-MM Envelope Mandatory Measures Form L TG-MM Lighting Mandatory Measures Form MECH-MM Mechanical Mandatory Measures EnergyPro 3.1 By EnergySoft Job Number: 1 2 3 13 14 15 User Number: 3429 IPERFORMANCE CERTIFICATE OF COMPLIANCE Part 1 of 3 PERF-11 PROJECT NAME DATE Acushnet Company -Warrantv Reoair/Ena. Lab 05/24/2002 PROJECT ADDRESS 2819 Loker Avenue East Carlsbad PRINCIPAL DESIGNER -ENVELOPE TELEPHONE Building Permit # DOCUMENTATION AUTHOR TELEPHONE Stueven Enqineerinq Consultants (760) 735-8577 Checked by/Date Enforcement Agency Use GENERAL INFORMATION DATE OF PLANS !BUILDING CONDITIONED FLOOR AREA I CLIMATE ZONE 7 1,850 Sq.Ft. BUILDING TYPE [X] NONRESIDENTIAL D HIGH RISE RESIDENTIAL D HOTEUMOTEL GUEST ROOM PHASE OF CONSTRUCTION D NEW CONSTRUCTION D ADDITION [Zj ALTERATION D EXISTING + ADDITION STATEMENT OF COMPLIANCE This Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6, of the State Building Code. This certificate applies only to a Build in , he performance compliance approach. DOCUMENTATION AUTHOR SIG TU DA E Steve Balderrama CEPE · ---------S U d'L The Principal Designers hereby certify that the proposed building design represented in the construction documents and modelled for this permit application are consistent with all other forms and worksheets, specifications, and other calculations submitted with this permit application. The proposed building as designed meets the energy efficiency requirements of the State Building Code, Title 24, Part 6. ENV. L TG. MECH. D D D D D D D 1. I hereby affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code to sign this document as the person responsible for its preparation; and that I am licensed as a civil engineer, mechanical engineer, electrical engineer or architect. D 2. I affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code Section 5537.2 or 6737.3 to sign this document as the person responsible for its preparation; and that I am a licensed contractor preparing documents for work that I have contracted to perform. 3. I affirm that I am eligible under Division 3 of the Business and Professions Code to sign this document because it pertains to a structure or type of work described as exempt pusuant to Business and Professions Code Sections 5537, 5538, and 6737.1. (These sections of the Business and Professions Code ae printed in full in the Nonresidential Manual.) ENVELOPE COMPLIANCE Indicate location on plans of Note Block for Mandatory Measures f-....-----------------------l Requi d Forms ENV-1 PRINCIPAL ENVELOPE DESIGNER· NAME LIGHTING COMPLIANCE PRINCIPAL LIGHTING DESIGNER -NAME MECHANICAL COMPLIANCE PRINCIPAL MECHANICAL DESIGNER -NAME Southcoast Heatin & Air Conditionin EnergyPro 3.1 By EnergySoft User Number: 3429 UC. NO. DATE DATE MECH-2 MECH-3 Run Code: 1022258908 Job Number: Page:3 of 16 I PERFORMANCE CERTIFICATE OF COMPLIANCE Part 2 of 3 PERF-11 DATE 05/24/2002 ANNUAL SOURCE ENERGY USE SUMMARY kBtu/saft-vr) Standard Proposed Compliance ENERGY COMPONENT Design Design Margin iffsiir,~i.g~,--:~ '.:--:~:-:-·-:~.-:a:P&g<i!;~.,: .·: ,,,, .N,., l Space Heating 0.00 Space Cooling 26.11 Indoor Fans 12.49 Heat Rejection 0.00 Pumps & Misc. 0.00 Domestic Hot Water 0.00 Lighting 44.11 Receptacle 16.86 Process 0.00 TOTALS: 99.57 GENERAL INFORMATION Building Orientation Number of Stories Number of Systems Number of Zones f' 0.16 -0.16 1'! -~poe& HelllJng: ,, ,,Sp~Coolms,1, ,. .. , 18.16 7.95 ! -- 15.41 -2.92 Indoor Fans, ; 0.00 0.00 Hoa.t ReJecllOn 0.00 0.00 ; Pt.lmp$'&'M~ 0.00 0.00 DHW ' - 30.16 13.95 lJghl!og ' 16.86 0.00 ! , Recept~e , ; 0.00 0.00 : Pr~ss : •-;.:.;t-.;::::--., • 0 10 ' 80.76 18.81 ______ ..........._,,,_,.,.,., -· -~_,,,,,.,,_ BUILDING COMPLIES 1------~<N_o_rt_h~)O_d_lea= Conditioned Floor Area 1 Unconditioned Floor Area f----------1 ,___ _______ _,2 Conditioned Footprint Area 3 .. ,··1, ,, ... kBIU/sqft-yr .. 3!)' 1,850 sqft 1,000 sqft. 1,850 sqfl ' ,: ' ~ '! ,, A ' ~J ,, id . ! ;~ ! d /:•; "I i ! 'ij l .. 40 \ __.,_..,,,,.,,,,... ___ ,,_ -1 Orientation Gross Area Glazing Area Glazing Ratio Remarks: Front Elevation Left Elevation Rear Elevation Right Elevation Roof Total Lighting Power Density Prescriptive Env. Heat Loss Prescriptive Env. Heat Gain (North (East (South (West I Standard ~W/~ft 0 sqft. 0 sqft. 0 sqft. 0 sqft. 0 sqft. 0 sqft. 0 sqft. 0 sqft. 0 sqft. 0 sqft. oJsqft. J olsqft. Proposed ~W/sqft I Run Initiation Time: 05/24/02 09:48:28 Run Code: 1022258908 0.0% 0.0% 0.0% 0.0% 0.0% I 0.0%1 I I EnergyPro 3.1 By EnergySoft User Number: 3429 Job Number: Page:4 of 16 I IPERFORMANCE CERTIFICATE OF COMPLIANCE Part 3 of 3 PERF-11 PROJECT NAME 'DATE Acushnet Company -Warranty Repair/EnQ. Lab 05/24/2002 ZONE INFORMATION Floor Inst. Port. Ctrl. Tailored Proc. Area LPD LPD Credits LPD Loads System Name Zone Name Occupancy Type (sqft.) (W/sf)1 (W/sf)1 (W/sf)2 (W/sf)3 (W/sf) HP-1 HP-1 Precision Industrial 950 1.762 0.000 Existing Heat Pump Existing Heat Pump Precision Industrial 900 0.240 0.000 Warehouse Unconditioned 1,000 0.000 0.000 Notes: 1. See L TG-1 (items marked with asterisk, see L TG-2 by others) 2. See LTG-3 3. See LTG-4 Items above require special documentation EXCEPTIONAL CONDITIONS COMPLIANCE CHECKLIST The local enforcement agency should pay special attention to the items specified in this checklist. These items require special written justification and documentation, and special verification to be used with the performance approach. The local enforcement agency determines the adequacy of the justification, and may reject a building or design that otherwise complies based on the adequacy of the soecial iustificati and documentation submitted. Plan Field The Room "Warehouse" has a Heating Indoor Design Temperature of 50 deorees F. The Room "Warehouse" has a Cooling Indoor Desion Temperature of 95 deorees F. The exceptional features listed in this performance approach application have specifically been reviewed. Adequate written justification and documentation for their use have been provided by the applicant. Authorized Signature or Stamp ________________ _ Run Initiation Time: 05/24/02 09:48:28 Run Code: 1022258908 EnergyPro 3.1 By EnergySoft User Number: 3429 Job Number: Page:5 of 16 on !ENVELOPE COMPLIANCE SUMMARY Performance ENV-1f 'PROJECT NAME DATE I Acushnet Company -Warranty Repair/EnQ. Lab 05/24/2002 OPAQUE SURFACES Solar Surface Framing Act. Gains # Type Type Area U-Fac. Azm. Tilt Y/N Form 3 Reference Location / Comments 1 Demisina Metal 846 0.189 0 90 X R-11 Metal Stud Wall HP-1 <faces Warehouse) 2 Demisina Metal 810 0.189 0 90 X R-11 Metal Stud Wall Existina Heat Pumo <faces Warehouse) FENESTRATION SURFACES Site Assembled Glazing D Check box if Building is >= 100,000 sqft of CFA and >= 10,000 sqft vertical glazing then NFRC Cert1ficat1on Is required. Follow NFRC 100-SB Procedures and submit NFRC Label Certificate Form # Type Area U-Fac. Act. Azm. SHGC Glazing Type Location / Comments EXTERIOR SHADING Window Overhang Left Fin Right Fin # Exterior Shade Type SHGC Hgt. Wd. Len. Hat. LExt.RExt. Dist. Len. Hat. Dist. Len. Hat. Run Initiation Time: n5/24/02 n9:48:28 R11n r:nrlo: 1022258908 EnergyPro 3.1 By EnergySoft User Number: 3429 Job Number: Page:6 of 16 ILIGHTING COMPLIANCE SUMMARY PROJECT NAME Acushnet Com an !INSTALLED LIGHTING SCHEDULE LUMINAIRE Code DESCRIPTION (1) 8w Fluorescent Preheat T5 (3) 4 ft Fluorescent TB Elec Lighting Schedule on Plans Shows Exterior Lighting Meets D Efficacy and Control Requirement of§130(c) D Control Requirements of§131(f) !MANDATORY AUTOMATIC CONTROLS LAMPS TYPE DESCRIPTION ll=RT5 F32T8 # 1 '.! Part 1 of 2 L TG-11 DATE 05/24/2002 BALLASTS Luminaire Watts I (Lamp + Ballast Total Per Lamp DESCRIPTION # # Watts Watts 8 Maanetic Standard 1.n 18 12.n 216 32 Electronic 1.( 18 a-:in Subtotal from this Page Total Portable Lighting (From L TG-1) Less Control Credit Watts (From L TG-3) Adjusted Actual Watts 1 674 1,8901 1,8901 al al 1,8901 CONTROL LOCATION CONTROL CONTROL TYPE NOTE TO (Room#) IDENTIFICATION (Auto Time Switch, Exterior, etc.) SPACE CONTROLLED FIELD !CONTROLS FOR CREDIT CONTROL LOCATION CONTROL CONTROL TYPE LUMIN11IRES r-nNTROLLED NOTE TO (Room # or Dwg. #) IDENTIFICATION (Occupant, Daylight, Dimming, etc.) TYPE # OF LUMINAIRES FIELD NOTES TO FIELD -For Buildina Deoartment Use Onlv Run Initiation Time: 05/24/02 09:48:28 Run Code: 1022258908 EnergyPro 3.1 By EnergySoft User Number: 3429 Job Number: Page:7 of 16 ILIGHTING COMPLIANCE SUMMARY Part 2 of 2 L TG-11 PROJECT NAME DATE Acushnet Com 05/24/2002 !TABLE 1A -PORTABLE LIGHTING NOT SHOWN ON PLANS FOR OFFICE AREAS >250 SQUARE FEET ROOM# DEFAULT AREA TOTAL WATTS ORZONEID lW/saft) {SF) CBXC) TOTAL 0 0 ITABLE 1B -PORTABLE LIGHTING SHOWN ON PLANS FOR OFFICE AREAS >250 SQUARE FEET ROOM# ONEID ORZ PORTABLE LIGHTING Description LUMIN. TASK # OF WATTS PER AREA FIXT FIXTURE (SF) #OF TASK AREAS TOTAL 0 @] TOTAL TOTAL AREA (SF) WATTS X X (D E) (C E) 0 0 iTABLE 1C -PLANS SHOW PORTABLE LIGHTING IS NOT REQUIRED FOR OFFICE AREAS> 250 SQUARE FEET ROOM# TOTAL AREA ORZONEID (SF) Designer needs to provide detailed documentation that the lightin ;i level provided by the overhead lighting meets the needs of the space. The details include luminaire types, CU, and mounting locations relative to work areas. TOTAL 0 IBUILDING SUMMARY -PORTABLE LIGHTING I TOTAL AREA (SF} TOTAL WATTS BUILDING SUMMARY (FROM TABLES 1A+1B+1C) (FROM TABLES 1A+1B} BUILDING TOTAL 0 0 I Run Initiation Time: 05/24/02 09:48:28 Run Code: 1022258908 I EnergyPro 3.1 By EnergySoft User Number: 3429 Job Number: Page:8 of 16 !CERTIFICATE OF COMPLIANCE Performance MECH-11 PROJECT NAME DATE Acushnet Com 05/24/2002 !SYSTEM FEATURES MECHANICAL SYSTEMS !SYSTEM NAME HP-1 Existing Heat Pump NOTE TO FIELD TIME CONTROL Programmable Switch Programmable Switch SETBACK CONTROL No Setback Reouired No Setback Reauired ISOLATION ZONES n/a n/a HEAT PUMP THERMOSTAT? Yes Yes ELECTRIC HEAT? 0.0kW 0.0kW FAN CONTROL Constant Volume Constant Volume VAV MINIMUM POSITION CONTROL? No No SIMULTANEOUS HEAT/COOL? No No HEATING SUPPLY RESET Constant Temo Constant Temo COOLING SUPPLY RESET Constant Temp Constant Temp HEAT REJECTION CONTROL n/a n/a VENTILATION Air Balance Air Balance OUTDOOR DAMPER CONTROL Auto Auto ECONOMIZER TYPE No Economizer No Economizer DESIGN 0.A. CFM CMECH-3, COLUMN I 143 cfm 135 cfm HEATING EQUIPMENT TYPE Heat Pumo Heat Pumo HEATING EQUIPMENT EFFICIENCY 7.10 HSPF 6.90 HSPF COOLING EQUIPMENT TYPE Packaaed DX Packaaed DX COOLING EQUIPMENT EFFICIENCY 12.0 SEER/ 10.4 EER 12.0 SEER/ 10.2 EER MAKE AND MODEL NUMBER CARRIER 50JX024 CARRIER 50HX024 PIPE INSULATION REQUIRED? Yes Yes PIPE/DUCT INSULATION PROTECTED? Yes Yes HEATING DUCT LOCATION R-VALUE Ducts in Attic 4.2 Ducts in Attic 4.2 COOLING DUCT LOCATIOII R-VALUE Ducts in Attic 4.2 Ducts in Attic 4.2 VERIFIED SEALED DUCTS IN CEILING/ROOF SPACE No No CODE TABLES: Enter code from table below into columns above. HEAT PUMP THERMOSTAT? TIME CONTROL SETBACK CTRL. ISOLATION ZONES FAN CONTROL ELECTRIC HEAT? S: Prog. Switch H: Heating Enter Number of I: Inlet Vanes 0: Occupancy C:Cooling Isolation Zones. P: Variable Pitch VAV MINIMUM POSITION CONTROL? Sensor B: Both V:VFD SIMULTANEOUS HEAT/ COOL? Y:Yes M: Manual Timer O: Other C: Curve N:No HEAT AND COOL SUPPLY RESET? VENTILATION OUTDOOR DAMPER ECONOMIZER O.A. CFM HIGH EFFICIENCY? B: Air Balance A: Auto A:Air Enter Outdoor Air C: Outside Air Cert. G: Gravity W: Water CFM. PIPE INSULATION REQUIRED? M: Out. Air Measure N: Not Required Note: This shall be nc PIPE/DUCT INSULATION PROTECTED? D: Demand Control EC: Economizer less than Col. H on N: Natural Control See Section MECH-3. SEALED DUCTS IN CEILING/ROOF SPACE!? 144(e)3 !NOTES TO FIELD -For Building Department Use Only Run Initiation Time: 05/24/02 09:48:28 Run Code: 1022258908 EnergyPro 3.1 By EnergySoft User Number: 3429 Job Number: Page:9 of 16 !MECHANICAL EQUIPMENT SUMMARY Part 1 of 2 MECH-21 !PROJECT NAME , Acushnet Comoanv -Warrantv Reoair/Ena. Lab IDAT1)5/24/2002 I CHILLER AND TOWER SUMMARY PUMPS Tot. Motor Drive Pump Equipment Name Equipment Type Qty. Efficiency Tons Qty GPM BHP Eff. Eff. Control DHW I BOILER SUMMARY Energy Factor Standby TANK INSUL. Rated Vol. or Recovery Loss or Ext. System Name System Type Distribution Type Qt} Input (Gals.) Efficiency Pilot R-Val. CENTRAL SYSTEM RATINGS HEATING COOLING Aux. Svstem Name SvstemTvoe Qtv. Outout kW Eff. Outout Sensible Efficiency Economizer Type CARRIER 50JX024 Packaged DX 1 23,200 0.0 7.10HSPF 23,200 16,24( 12.0 SEER/ 10.4 EER No Economizer CARRIER 50HX024 Packaged DX 1 23,200 0.0 6.90HSPF 23,200 16,24C 12.0 SEER/ 10.2 EER No Economizer CENTRAL SYSTEM FAN SUMMARY .SIIDPLYFAN RETURN FAN Motor Drive Motor Drive System Name FanTYoe Motor Location CFM BHP Eff. Eff. CFM BHP Eff. Eff. CARRIER 50JX024 Constant Volume Blow-Through 800 0.33 77.0% 100.0% none CARRIER 50HX024 Constant Volume Blow-Through 800 0.33 77.0% 100.0% none Run Initiation Time: 05/24/02 09:48:28 Run Code: 1022258908 EnergyPro 3.1 By EnergySoft User Number: 3429 Job Number: Page:10 of 16 IMECHANICAL EQUIPMENT SUMMARY Part 2 of 2 MECH-2f PROJECT NAME I DAT1)5/24/2002 Acushnet Comoanv -Warrantv Reoair/Ena. Lab ZONE TERMINAL SUMMARY VAV TERMINAL BOX TERMINAL FAN BASEBOARD Min. CFM Reheat Coil MotoI Drive Zon"' Name Svstem Tvoe Qtv. Ratio Tvoe DeltaT CFM BHP Eff. Eff. Type Output EXHAUST FAN SUMMARY 1-XHAl1 SI t-AN ,a •LIA L·--i CAM Motor Drive Motor Drive Room Name Qty, CFM BHP Eff. Eff. Room Name Qtv. CFM BHP Eff. Eff. Run Initiation Time: 05/24/02 09:48:28 Run Code: 1022258908 EnergyPro 3.1 Bv EnergySoft User Number: 3429 Job Number: Page:11 of16 IMECHANICAL VENTILATION PROJECT NAME Acushnet Com IMECHANICAL VENTILATION AREA BASIS OCCUPANCY BASIS REQ'D COND. MIN. NO. CFM MIN. O.A. ZONE/SYSTEM AREA CFM CFM OF PER CFM (MAX OF (SF) PER SF (BxC) PEOPLE PERSON (ExF) DORG) HP-1 950 0.15 142 142 HP-1 Total 142 Existing Heat Pump 900 0.15 135 135 Existing Heat Pump Total 135 Minimum Ventilation Rate per Section 121, Table 1-F. Based on Expected Number of Occupants or at least 50% of Chapter 10 1997 UBC Occupant Density. MECH-31 DATE 05/24/2002 w -DESIGN OUTDOOF VAV TRANS AIR MIN. FER CFM RATIO AIR - 143 - 143 - 135 ,___ 135 ,___ - - - - ,----- ,----- ,----- - - ,----- ,----- ,___ -- - - ,____ ,____ ,____ - - -- - m Must be greater than or equal to H, or use Transfer Air. Design Outdoor Air includes ventilation from Supply Air System & Room Exhaust Fans. Must be greater than or equal to (H minus I), and, for VAV, greater than or equal to (H-J). EnergyPro 3.1 By EnergySoft User Number: 3429 Job Number: Page:12 of 16 !ENVELOPE MANDATORY MEASURES ENV-MMI DATE 05/24/2002 DESCRIPTION Designer Enforcement D § 118(a) Installed Insulating Material shall have been certified by the manufacturer to comply with the California Quality Standards for insulating material, Title 20, Chapter 4, Article 3. D § 118(c) All Insulating Materials shall be installed in compliance with the flame spread rating and smoke density requirements of Sections 2602 and 707 of Title 24, Part 2. D § 117(a) All Exterior Joints and openings in the building that are observable sources of air leakage shall be caulked, gasketed, weatherstripped or otherwise sealed. D §116(b) Site Constructed Doors, Windows and Skylights shall be caulked between the unit and the building, and shall be weatherstripped_ (except for unframed glass doors and fire doors). D § 116(a)1 Manufactured Doors and Windows installed shall have air infiltration rates not exceeding those shown in Table Number 1-E. of the Standards. Manufactured fenestration products must be labeled for LI-value according to NFRC procedures. D § 118(e) Demising Walls in Nonresidential Buildings: The opaque portions of framed demising walls in nonresidential buildings shall have insulation with an installed R-value of no less than R-11 between framing members. EnergyPro 3.1 By EnergySoft User Number: 3429 Job Number: Page:13 of16 !LIGHTING MANDATORY MEASURES LTG-MMI PROJECT NAME DATE Acushnet Com -Warrant 05/24/2002 DESCRIPTION Designer Enforcement D § 131 (d)1 For every floor, all interior lighting systems shall be equipped with a separate automatic control to shut off the lighting. This automatic control shall meet the requirements of Section 119 and may be an occupancy sensor, automatic time switch, or other device capable of automatically shutting off the lighting. D § 131(d)2 Override for Building Lighting Shut-off: The automatic building shut-off system is provided with a manual, accessible override switch in sight of the lights. The area of override is not to exceed 5,000 square feet. D § 119(h) Automatic Control Devices Certified: All automatic control devices specified are certified, all alternate equipment shall be certified and installed as directed by the manufacturer. D § 111 Fluorescent Ballast and Luminaires Certified: All fluorescent fixtures specified for the project are certified and listed in the Directory. All installed fixtures shall be certified. D § 132 Tandem Wiring for One and Three Lamp Fluorescent Fixtures: All one and three lamp fluorescent fixtures are tandem wired with two lamp ballasts where required by Standards Section 132; or all one and three lamp fluorescent fixtures are specified with electronic high-frequency ballasts and are exempt from tandem wiring requirements. D § 131(a) Individual Room/Area Controls: Each room and area in this building is equipped with a separate switch or occupancy sensor device for each area with floor-to-ceiling walls. D § 131(b) Uniform Reduction for Individual Rooms: All rooms and areas greater than 100 square feet and more than 0.8 watts per square foot of lighting load shall be controlled with bi-level switching for uniform reduction of lighting within the room. D § 131(c) Daylight Area Control: All rooms with windows and skylights that are greater than 250 square feet and that allow for the effective use of daylight in the area shall have 50% of the lamps in each day lit area controlled by a separate switch; or the effective use of daylight cannot be accomplished because the windows are continuously shaded by a building on the adjacent lot. Diagram of shading during different times of the year is included on plans. D § 131(f) Control of Exterior Lights: Exterior mounted fixtures served from the electrical panel inside the building are controlled with a directional photo cell control on the roof and a corresponding relay in the electrical panel, or uses an astronomical time clock. D § 131(e) Display Lighting. Display lighting shall be separately switched on circuits that are 20 amps or less. D § 130(c) Efficacy of Exterior Lights: Exterior mounted fixtures with lamps over 100 Watts served from the electrical panel inside the building have a source efficacy of at least 60 lumens per Watt, or are controlled by a motion sensor. EnergyPro 3.1 By EnergySoft User Number: 3429 Job Number: Page:14 of 16 !MECHANICAL MANDATORY MEASURES Part 1 of 2 MECH-MMj PROJECT NAME DATE Acushnet Com -Warrant 05/24/2002 DESCRIPTION Designer Enforcement Equipment and Systems Efficiencies D §111 Any appliance for which there is a California standard established in the Appliance Efficiency Regulations will comply with the applicable standard. D § 115(a) Fan type central furnaces shall not have a pilot light. ~ § 123 Piping, except that conveying fluids at temperatures between 60 and 105 degrees Fahrenheit, or within HVAC equipment, shall be insulated in accordance with Standards Section 123. ~ § 124 Air handling duct systems shall be installed and insulated in compliance with Sections 601, 603 and 604 of the Uniform Mechanical Code. Controls § 122(e) Each space conditioning system shall be installed with one of'the following: lKl § 122(e)1A Each space conditioning system serving building types such as offices and manufacturing facilities (and all others not explicitly exempt from the requirements of Section 112 (d)) shall be installed with an automatic time switch with an accessible manual override that allows operation of the system during off-hours for up to 4 hours. The time switch shall be capable of programming different schedules for weekdays and weekends; incorporate an automatic holiday "shut- off'' feature that turns off all loads for at least 24 hours, then resumes the normally scheduled operation; and has program backup capabilities that prevent the loss of the device's program and time setting for at least 10 hours if power is interrupted; or D § 122(e)1 B An occupancy sensor to control the operating period of the system; or D § 122(e)1 C A 4-hour timer that can be manually operated to control the operating period of the system. D § 122(e)2 Each space conditioning system shall be installed with controls that temporarily restart and temporarily operate the system as required to maintain a setback heating and/or a setup cooling thermostat setpoint. D § 122(g) Each space conditioning system serving multiple zones with a combined conditioned floor area more than 25,000 square feet shall be provided with isolation zones. Each zone: shall not exceed 25,000 square feet; shall be provided with isolation devices, such as valves or dampers, that allow the supply of heating or cooling to be setback or shut off independently of other isolation areas; and shall be controlled by a time control device as described above. D § 122(a&b) Each space conditioning system shall be controlled by an individual thermostat that responds to temperature within the zone. Where used to control heating, the control shall be adjustable down to 55 degrees F or lower. For cooling, the control shall be adjustable up to 85 degrees F or higher. Where used for both heating and cooling, the control shall be capable of providing a deadband of at least 5 degrees F within which the supply of heating and cooling is shut off or reduced to a minimum. D § 122(c) Thermostats shall have numeric setpoints in degrees Fahrenheit (F) and adjustable ~ setpoint stops accessible only to authorized personnel. § 112(b) Heat pumps shall be installed with controls to prevent electric resistance supplementary heater operation when the heating load can be met by the heat pump alone. EnergyPro 3.1 By EnergySoft User Number: 3429 Job Number: Page:15 of 16 . . !MECHANICAL MANDATORY MEASURES Part 2 of 2 MECH-MM I PROJECT NAME DATE Acushnet Com -Warrant 05/24/2002 Description Designer Enforcement Ventilation ~ § 121(e) Controls shall be provided to allow outside air dampers or devices to be operated at the ventilation rates as specified on these plans. D § 122(f) Gravity or automatic dampers interlocked and closed on fan shutdown shall be provided on the outside air intakes and discharges of all space conditioning and exhaust systems. D § 122(f) All gravity ventilating systems shall be provided with automatic or readily accessible manually operated dampers in all openings to the outside, except for combustion air openings. D § 121(f)1 Air Balancing: The system shall be balanced in accordance with the National Environmental Balancing Bureau (NEBB) Procedural Standards (1983), or Associated Air Balance Council (AABC) National Standards (1989); or D § 121(f)2 Outside Air Certification: The system shall provide the minimum outside air as shown on the mechanical drawings, and shall be measured and certified by the installing licensed C-20 mechanical contractor and certified by (1) the design mechanical engineer, (2) the installing licenced C-20 mechanical contractor, or (3) the person with overall responsibility for the design of the ventilation system; or D § 121(f)3 Outside Air Measurement: The system shall be equipped with a calibrated local or remote device capable of measuring the quantity of outside air on a continuous basis and displaying that quantity on a readily accessible display divice; or D § 121(f)4 Another method approved by the Commission. Service Water Heating Systems D § 113(b)2 If a circulating hot water system is installed, it shall have a control capable of automatically turning off the circulating pump(s) when hot water is not required. D § 113(b)3B Lavatories in restrooms of public facilities shall be equipped with controls to limit the outlet temperature to 110 degrees F. D § 113(b)3C Lavatories in restrooms of public facilities shall be equipped with one of the following: Outlet devices that limit the flow of hot water to a maximum of 0.5 gallons per minute. Foot actuated control valves, and outlet devices that limit the flow of hot water to a maximum of 0.75 gallons per minute. Proximity sensor actuated control valves, and outlet devices that limit the flow of hot . water to a maximum of 0. 75 gallons per minute. Self-closing valves, and outlet devices that limit the flow of hot water to a maximum of 2.5 gallons per minute, and 0.25 gallons/cycle ( circulating system). Self-closing valves, and outlet devices that limit the flow of hot water to a maximum of 2.5 gallons per minute, and 0.50 gallons/cycle (non-circulating system). Self-closing valves, and outlet devices that limit the flow of hot water to a maximum of 2.5 gallons per minute, and 0.75 gallons/cycle (foot switches and proximity sensor controls). EnergyPro 3.1 By EnergySoft User Number: 3429 Job Number: Page:16 of 16 _) 08021383 2819LOKERAVEASTCBAD ACUSHNET COMPANY :Tl 1792SF Tl COMM Lot#: DBML INC c;/1f6v 5 -;;M~o-:J-, n. u~ Br/,!£ b fiJ c...Lfv} . ~ S--2-B-oz 6-2-1--02 ~-e-f;C. t;;.5 ~ (... Lh--J ,(, L~ fL'½> b ( c: 7M ul,-~ tufa . i-/.Ml}.e-~ ~ s: -() (5 Tl'.,_, 0~ 71/4 ~ c.A-.-, IMUllNG • 'I :;;1 ;;;::::: PLANNINl3 -/ ""',q'.:'¼;=~Z-::::.::.::_::: ENGINEERINl3 FIRE APPR/FORM HEALTH DEPT :::::::::= HAZ MAT/ AIR QI/AL OTHER SEWER D18111 TO FROM 8U>8 GRADINGLEnEII · r~·r--=-CFDFORM PE & M WORKSIIEE1' BLDG FEES COMPI.El'E ·" LEGEND SCOPE OF WORK 1. COMPLETE DRYWALL ON EXISTING STEEL STUD WALLS 2. RELOCATE DOUBLE DOORS 3. BUILD TIN CAN DIVIDER WALL, INSULATE, DRYWALL AND TAPE -J ,x-'I/ 4. REMOVE NON USED AIR HANDLING UNIT AND REPLACE WITH 2 TON HV AC UNIT ON EXISTING CURB. USING EXISTING PENETRATIONS DUCT TO NEW WORK AREA (SEE MECHANICAL). 5. RE-DUCT EXISITNG HV AC UNIT IN NEW WORK AREA 6. INSTALL NEWT-BAR CEILING WITH CEILING INSULATION R-1.f I 3 7. DROP EXISTING AND PROVIDE NEW, FIRE SPRINKLERS TO NEW ELEVATIONS. 8. INST ALL NEW FLOUR.ES CENT LIGHTING 9. PROVIDE WALL OUTLETS WITH NEW CIRCUITS (2) AND DATA CONDUITS 10. FINJSH FLOORS TO BE COMMERCIAL GLUE DOWN CARPETS SPEC'S 1. ALL WALL INSULATION TO BER-ii 13 / 2. ALL CEILING INSULATION TO BER-~ 1.1/' 3. LIGHTING TO BE 277 VOLT / 4. ELECTRJC CIRCUITS TO BE 20 AMP-yJo/ 5. GYPSUM TO BE 5/8" --\ 'f:i '' / ., -· l ) 0 .--7 PRODUCTION · i I I I I I I QA lc::rPAP t-P~A --~ARKIN.G SUMMARY: I . . STD. CCMPACT I-IC TOTAL EXISTING 2W 6 ADDED -2 • 25 0 TOTAL 44 8 F~ REGlUIRB1ENTS EXISTING ~T U5E $UB-TOTAL5 T:TLE16T USE e!JB-TOTAl..5 -r-orAL FAFiKI~ REQJIRED 70T AL PM;K!~ PROVIDED 1'iOTE: AREA l,'?)00 of. 21,11., &F. 0 22,11E> 5F. 4 21 (l) 25 AREA FAf.KJN:'.; ~S,cJo3 :i:: 112 2. 3,!..-9 ~ ·' r ~ 'f 15,441 SF. I '?) i 1B-IANT SPACE W.AS F'REVIOU5LY A MANUFACruRJ-t', FACILITY FOR Cl-lRCMIUM 6R.AA-IIC5 INC . .? '"' ~· ",' I SERVER RM. PRODUCTION PUTTERS 0 COMPANY STORE GYM 0 ENGINEERING AND REPAIR OFFICE 'fOTAL SQUARE FOOTAGE 1,792 _·:i.:,.-~.--~J-.'L t,,r-~p :)p;1nklz:..J v'\--c ~ c.•·~', f'v-c.f'C >, A --r-- ~~!t:!:!~ ea;lsbad Tract 74-21, in the City of Carlsbad, County of San Diego State of Diego County, AprJl;. ~?2 ~:;:f:;~~!{~; ~~!:~:;;of ~e County Record~r of San 1997 as Document No. 1997-0074335 of Official: R rds mpliance recorded February 19, eco . Assessor's Parcel No: 209-083-16 .... . ·:~ . ~i ,, ... ,. . , LUNCH ROOM CEILINGS@ 9" . -----·· ·------------------·· ............................................................ , ' I ; \ ···---··-------------·-····· .. ······································ ----------······-·-------················· ·--------···· .0 : PRODUCTION GRINDING ---··.·-:::-·:_-:;--. . ,·.:.. .. :;-:· -,· -.. :_:_:.~~:;.-_;: :~.-. ,. ------ ---~-. -... .0 ELEC. PHONE r-------- MAINT./ENG./FAC./ SAFETY STORAGE \ .o : ........ ! :z: I ::e i ... > "" Q >-z <( (L 2 0 0 1-w z I Cf) ::) 0 <{ l- '-L_ f;..-I c..c.. -. .... -:-....:. .., .... .... .., -...... 0 .... .=i >< - C, ""' -x . ;;: C, 0 ..::~ IJ ._ !_i~~ __ _ ._ ... I ~10F -----------------------------'------=-