Loading...
HomeMy WebLinkAbout2821 CACATUA ST; ; CB991972; PermitCity of Carlsbad 4 a 10/22/1999 Resident ia I Perm it Permit No:CB991972 Building Inspection Request Line (760) 438-31 01 Job Address: Permit Type: Parcel No: Valuation: Occupancy Group: # Dwelling Units: Bedrooms: Project Title: 2821 CACATUA ST CBAD RESDNTL SubType: RAD 21 53702600 Lot #: 0 $20,482.00 Construction Type: VN 27 Reference #: 0 Structure Type: 0 Bathrooms: 0 RAD 209 SF-2ND STRY ADDITION Applicant: MONTELLO TERRY Status: ISSUED Applied: 05/24/1999 Plan Approved: 10/22/1999 Issued: 10/22/1999 Entered By: JM Inspect Area: Orig PC#: Plan Check#: 5360 201'Z2/W 3001 (11 02 2331 Y gt7 Owner: TRYGSTAD JEAN W C-PRHT 471 5 60TH STREET SAN DIEGO CA 921 15 61 9-229-0642 Building Permit Add'l Building Permit Fee Plan Check Add'l Plan Check Fee Plan Check Discount Strong Motion Fee Park in Lieu Fee Park Fee LFM Fee Bridge Fee Other Bridge Fee BTD #2 Fee BTD #3 Fee Renewal Fee $0.00 Add'l Renewal Fee $0.00 Other Building Fee $0.00 Pot. Water Con. Fee $0.00 Meter Size Add'l Pot. Water Con. Fee $0.00 Recl. Water Con. Fee $0.00 -"=T"~"CTRICAL TOTAL MECHANICAL TOTAL Housing Impact Fee Housing InLieu Fee Master Drainage Fee: Sewer Fee: TOTAL PERMIT FEES $20.00 $0.00 $0.00 $0.00 $0.00 $0.00 $368.27 review, set aside, void, or annul their imposition. CITY OF CARLSBAD 2075 Las Palmas Dr., Carlsbad, CA 92009 (760) 438-1161 APPLICATION CITY OF CARLSBAD BUILDING DEPARTMENT 2075 Las Palmas Dr., Carlsbad CA 92009 (760) 438- 1 16 1 FOR OFFICE USE ONLY EST. VAL. Validated By A/- . Date (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law [Chapter 9, commendina with Section 7000 of Division 3 of the Business and Professions Code1 or that he is exemDt therefrom, and the basis for the alleaed 8 7 31.5 by any applicant for a permit subjects the applicant to a civil penalty of not.more than five hundred dollars IS5001). - 7&0-?W,y Nahd Address City Statelzip Telephone # P. .. License Class City Business License # &'?&&. F&+y O0-I -79) 'hD Pa& CJA w~@Q-kp 2/. < b flIt\C Addre& City Statelzip Telephdhe ' State License # nsation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. &have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My worker's compensa Insurance Company @.laqe (THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS [$lo01 OR LESS) 0 CERTIFICATE OF EXEMPTION: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. WARNING: Failure to secure workers' compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred Expiration Date \ 1 - 23 -09 I hereby affirm that I am exempt from the Contractor's License Law for the following reason: 0 I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044. Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s1 licensed pursuant to the Contractor's License Law). 0 1. 2. 3. 4. number I contractors license number): 5. of work): I am exempt under Section I personally plan to provide the major labor and materials for construction of the proposed property improvement. 0 YES I (have I have not) signed an application for a building permit for the proposed work. I have contracted with the following person (firm) to provide the proposed construction (include name I address I phone number / contractors license number): I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name I address I phone I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name I address I phone number I type Business and Professions Code for this reason: ON0 PROPERTY OWNER SIGNATURE DATE IS SECTION FOR Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? 0 YES 0 NO Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? 0 YES 0 NO Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? 0 YES 0 NO IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. DING AGE I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097(i) Civil Code). LENDER'S NAME LENDER'S ADDRESS I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all City ordinances and State laws relating to building construction. I hereby authorize representatives of the City of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE. INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA An OSHA permit is required for excavations over 5'0" deep and demolition or construction of structures over 3 stories in height. EXPIRATION: Every permit work authorized by such permit is n or abandoned at any time af APPLICANT'S SIGNATURE DATE limitation and become null and void if the building or e date of such permit or if the building or ys (Section 106.4.4 Uniform Building Code). WHITE: File YELLOW: Applicant PINK: Finance FROM : SAF CBNST FW NO. : 7687434118 Oct. 28 1999 09:55FM p5 LO -\+%% I' , City of Carlsbad Bldg Inspection Request For: 4/13/2000 Permit# CB991972 Inspector Assignment: PD Title: RAD 209 SF-2ND STRY ADDITION Description: Type: RESDNTL SubType: RAD Job Address: 2821 CACATUA ST Suite: Lot Location: APPLICANT MONTELLO TERRY Owner: TRYGSTAD JEAN W Remarks: Total Time: CD Description 19 Final Structural 29 Final Plumbing 39 Final Electrical 49 Final Mechanical 0 Phone: 76074341 18 Requested By: STEVE Entered By: CHRISTINE Act Comments I t Associated PCRs Inspection History Date Description 3/9/2000 13 Shear PaneWHD’s 3/9/2000 17 Interior LathlDrywall 3/6/2000 13 Shear PaneMHD’s 2/16/2000 17 Interior LathlDrywall 2/8/2000 13 Shear PanelslHD’s 2/8/2000 44 RoughlDucWDampers 1/24/2000 16 Insulation 1/24/2000 18 Exterior LathlDrywall 1/21/2000 16 Insulation 1/21/2000 18 Exterior LathlDrywall 1/14/2000 34 Rough Electric 12/29/1999 15 Roof/Reroof 12/22/1999 14 Frarne/Steel/BoltingNlding 11/15/1999 11 Ftg/Foundation/Piers 11/12/1999 11 Ftg/Foundation/Piers Act lnsp AP PD AP PD PA PD PA PD PA PD PA PD AP PD AP PD CA PD CA PD PA PD AP PD AP SR AP SR CO SR Comments INTERIOR UPSTAI RS FOR SIDING SUB FLOOR FRAME ONLY ND TO MOVE HD2A &WRAP PLMBING IN FTG. NEED SPECIAL INSPECTION ON DH-5A I CONSTRUCTION INSPECTIONS, INC. SAN DIEGO, CA 92111 TELEPHONE (858) 576-9110 APPROVAL BY CERTIFICATION OF COMPLIANCE: To the best of our knowledge, all Of the reported work, unless otherwise noted, substantially complies with approved pian: specifications and applicable sections of the building codes. This report covers the locations Of the work inspected only and does not constitute engineering opin. ion or project control. EsGil CorDoration In %aTtneTSfiip wit6 ~overnrnent for BuiHing Safety DATE: October 7, 1999 J U Rl SDl CTl ON : Carlsbad REVIEWER PLAN CHECK NO.: 99-1972 SET: I11 PROJECT ADDRESS: 2821 Cacatua St. PROJECT NAME: Room addition for Gene Trygstad residence (SFD) 0 FILE o w 0 0 0 0 w 0 w The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: Esgil Corporation staff did not advise the applicant that the plan check has been completed. Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Telephone #: Date contacted: (by: 1 Fax #: REMARKS: Applicant shall provide a "Special Inspection Program" to the Building Official. Mail Telephone Fax In Person By: Sergio Azuela Enclosures: Esgil Corporation GA MB EJ PC 9/29 trnsmtl .dot 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858) 560-1468 Fax (858) 560-1576 - EsGil - Corporation In Partnership with +jovrrnnrcnt for BuiHing Safety DATE: September 15, 1999 JURISDICTION : Carlsbad PLAN CHECK NO.: 99-1972 P APPLICANT PLAN REVIEWER 0 FILE 6sa SET: I1 PROJECT ADDRESS: 2821 Cacatua St. PROJECT NAME: Room addition for Gene Trygstad residence (SFD) 0 The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. 0 The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. 0 The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. 0 The applicant's copy of the check list is enclosed for the jurisdiction to fowvard to the applicant contact person. The applicant's copy of the check list has been sent to: Terry Montello 4715 60th St., San Diego, CA 921 I5 Esgil Corporation staff did not advise the applicant that the plan check has been completed. 0 Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Telephone #: Date contacted: (by: 1 Fax #: Mail Telephone Fax In Person 0 REMARKS: By: Sergio Azuela Enclosures: Esgil Corporation 0 GA 0 MB 0 EJ 0 PC 917 0 tmsmtl.dot 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858) 560-1468 + Fax (858) 560-1576 Carlsbad 99-1972 I1 September 15, 1999 RECHECK PLAN CORRECTION LIST PROJECT ADDRESS: 2821 Cacatua St. SET: I1 DATE PLAN RECEIVED BY ESGIL CORPORATION: 9R REVIEWED BY: Sercrio Azuela DATE RECHECK COMPLETED: September 15, 1999 FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and disabled access. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department or other departments. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. A. Please make all corrections on the original tracings and submit two new sets of prints to: Esgil Corp. or to the bldg. dept. of the juris. B. To facilitate rechecking, please identify, next to each item, the sheet of the plans upon which each correction on this sheet has been made and return this sheet with the revised plans. C. The following items have not been resolved from the previous plan reviews. The original correction number has been given for your reference. In case you did not keep a copy of the prior correction list, we have enclosed those pages containing the outstanding corrections. Please contact me if you have any questions regarding these items. D. Please indicate here if any changes have been made to the plgns that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located on the plans. Have changes been made not resulting from this list? OYes ONo Carlsbad 99- 1972 I1 September 15, 1999 1. Please make all corrections on the original tracings, as requested in the correction list. Submit three sets of plans for comrnerciaVindustriaI projects (two sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 2075 Las Palmas Drive, Carlsbad, CA 92009, (760) 438-1 161. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring one corrected set of plans and calculationslreports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (619) 560-1 468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. 4. Please revise the Table of REQUIRED SPECIAL INSPECTIONS to include the SOILS COMPLIANCE PRIOR TO FOUNDATION INSPECTION as shown below: 0 REQUIRED SPECIAL INSPECTIONS In addition to the regular inspections, the following checked items will also require Special Inspection in accordance with Sec. 1701 of the Uniform Building Code. ITEM REQUIRED? REMARKS SOILS COMPLIANCE PRIOR TO YES SOILS REPORT EXPANSlON/EPOXY ANCHORS YES SHEETS 3 & 5 FOUNDATION INSPECTION 5. Include the SOILS COMPLIANCE PRIOR TO FOUNDATION INSPECTION in the Special Inspection Program provided. The Building Department will resolve this correction. 13. From the soils report provided: 0 The soils engineer recommended that he/she review the foundation excavations. Note on the foundation plan that "Prior to the contractor requesting a Building Department foundation insphion, the soils engineer shall advise the building official in writing that: a) b) c) The building pad was prepared in accordance with the soils report, The utility trenches have been properly backfilled and compacted, and The foundation excavations, the soils expansive characteristics and bearing capacity conform to the soils report." Carlsbad 99- 1972 I1 September 15, 1999 0 Provide a letter from the soils engineer confirming that the foundation plan, grading plan and specifications have been reviewed and that it has been determined that the recommendations in the soils report are properly incorporated into the construction documents (required by the soil report Page 3)- If you have any questions regarding these plan review items, please contact Sergio Azuela at Esgil Corporation. Thank you. . EsGil Corr>oration In !Partnership with Government for BuiUing Safety DATE: June 8, 1999 JURI SDlCTl ON: Carlsbad PLAN CHECK NO.: 99-1972 a APPLICANT n PLAN REVIEWER 0 FILE SET: I PROJECT ADDRESS: 2821 Cacatua St. PROJECT NAME: Room addition for Gene Trygstad Residence (SFD) 0 0 0 w 0 w w 0 0 The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction’s building codes. The plans transmitted herewith will substantially comply with the jurisdiction’s building codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant’s copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant’s copy of the check list has been sent to: Terry Montello 4715 60th St., San Diego, CA 921 15 Esgil Corporation staff did not advise the applicant that the plan check has been completed. Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Telephone #: Date contacted: (by: 1 Fax #: REMARKS: Mail Telephone Fax In Person By: Sergio Azuela Enclosures: Esgil Corporation GA 0 MB EJ PC 5/27 trnsmtl.dot 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (619) 560-1468 + Fax (619) 560-1576 Carlsbad 99- 1972 June 8, 1999 PLAN REVIEW CORRECTION LIST SINGLE FAMILY DWELLINGS AND DUPLEXES PLAN CHECK NO.: 99-1972 JURISDICTION: Carlsbad PROJECT ADDRESS: 2821 Cacatua St. FLOOR AREA: Dwelling addition 209 SF STORIES: 2 HEIGHT: 28 FT REMARKS: DATE PLANS RECEIVED BY DATE PLANS RECEIVED BY JURISDICTION: 5/24/99 ESGIL CORPORATION: 5/27 DATE INITIAL PLAN REVIEW COMPLETED: June 8, 1999 PLAN REV1 EWER: Sergio Azuela FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinance by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Present California law mandates that residential construction comply with Title 24 and the following model codes: 1994 UBC (effective 12/28/95), 1994 UPC (effective 12/28/95), 1994 UMC (effective 2/23/96) and 1993 NEC (effective 12/28/95). The above regulations apply to residential construction, regardless of the code editions adopted by ordinance. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3, I994 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed up the recheck process, please note on this list (or a copv) where each correction item has been addressed, i.e., plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans. LIST NO. 1, GENERAL SINGLE FAMILY DWELLINGS AND DUPLEXES WITHOUT SUPPLEMENTS (1994 UBC) r3forw.dot Carlsbad 99- 1972 June 8, 1999 PLANS 1. Please make all corrections on the original tracings, as requested in the correction list. Submit three sets of plans for commercial/industriaI projects (two sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 2075 Las Palmas Drive, Carlsbad, CA 92009, (760) 438-1 161. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring one corrected set of plans and calculationsheports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 921 23, (61 9) 560-1 468. Deliver all remaining sets of plans and calculationsheports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. 2. Specify on the Title Sheet of the plans the gross floor area of each element of this project, including dwelling, garage, carport, patio, deck and balcony. Section 106.3.3. 3. Provide a statement on the Title Sheet of the plans that this project shall comply with Title 24 and the I994 UBC, UMC and UPC and the 1993 NEC. 4. On the cover sheet of the plans, specify any items requiring special inspection, in a format similar to that shown below. Section 106.3.2. 0 REQUIRED SPECIAL INSPECTIONS In addition to the regular inspections, the following checked items will also require Special Inspection in accordance with Sec. 1701 of the Uniform Building Code. ITEM REQUIRED? REMARKS SOILS COMPLIANCE PRIOR TO FO U N DATl 0 N INS PECTlO N To be rechecked with soils report * EXPANSIONIEPOXY ANCHORS YES SHEETS 3 & 5 5. When special inspection is required, the architect or engineer of record shall prepare an inspection program which shall be submitted to the building official for approval prior to issuance of the building permit. Please review Section 106.3.5. Please complete the attached form. Carlsbad 99- 1972 June 8, 1999 0 EXITS, STAIRWAYS, AND RAILINGS Since the proposed addition is located on the second floor the existing stairways shall be clearly shown on plans to be in full compliance with the current Code Regulations. Please clearly show on plans full compliance. Full compliance will be rechecked. 6. 7. 8. 9. IO. 11. 12. Required exit doorways shall be not less than 36" in width and not less than 6'8" in height. Section 1004.6. Provide stairway and landing details. Sections 1006.3, 1006.1 5 and 1006.2. a) Maximum rise is 7" and minimum run is 11". When the stairs serves less than IO occupants, or serves an unoccupied roof, rise may be 8" maximum and run 9" minimum. b) Minimum headroom is 6'-8". c) Minimum width is 36". Handrails: a) b) Handrails and extensions shall be 34" to 38" above nosing of treads and be continuous. All stairs shall have handrails terminating in a newel or safety post. Section 1006.9. The handgrip portion of all handrails shall be not less than 1-1/4 inches nor more than 2 inches in cross-sectional dimension. Handrails projecting from walls shall have at least I-1/2 inches between the wall and the handrail. Section 1006.9. ROOFING Specify on the plans the following information for the roof materials, per Section 106.3.3: a) Manufacturer's name. b) Product namelnumber. c) ICBO approval number, or equal. Show attic ventilation. Minimum vent area is 1/150 of attic area (or 1/300 of attic area if at least 50% of the required vent is at least 3 feet above eave vents or cornice vents). Show area required and area provided. Section 1505.3. Note on the plans: corrosion-resistant metal mesh with mesh openings of I /4-inch in dimension." Section 1505.3. "Attic ventilation openings shall be covered with Carlsbad 99- 1972 June 8, 1999 FOUNDATION REQUIREMENTS 13. 14. 15. 16. Provide a copy of the project soil report prepared by a California licensed architect or civil engineer. The report shall include foundation design recommendations based on the engineer's findings and shall comply with UBC Section 1804. 0 FRAMING Show location of attic access with a minimum size of 22"x30", unless the maximum vertical headroom height in the attic is less than 30". Access must be provided to each separated attic area, shall be located in a hallway or other readily accessible location and 30" headroom clearance is required above the opening. Section 1505.1. CARLSBAD S.F.D. & DUPLEX SUPPLEMENT All new residential buildings, including additions, require a soils report. Please submit two copies. Exception: If a room addition is limited to one story and I000 sq. ft. in area, then a soils report is not required. Esgil Corporation will advise the City to place their soils notice stamp on the plans. All structures require a Class A roof covering, except room additions. If a room addition covers all of the existing building (2nd story addition), then the above exception doesn't apply. To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please indicate: Yes 0 No 0 The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 61 9/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Sergio Azuela at Esgil Corporation. Thank you. OCT-13-99 WED 04:49 PM PERMITS IN MOTION SPECIAL INSPECTION PROGRAM 619 229 0642 P. 02 OCT-13-99 WED 10:54 P, 03 PLAN CHECK NUMBER: ....__OWNER’S NAME: I, as the owner, or agent of the owner (contractors may & employ the special Inspector), certify that I, or the architecthnginew of record, will be responslbfe for employing the special inspector&) 88 required by Uniform Building Code (UBC) Section 1701.1 for the construction Signed u(c Secbon 106.3.5. I, as the rtngineor/arChlted of record, certify that I have prepared the following special inspection program as requited by UBC Section 106,3.5 for the construction project located at the site listed above. 4~zYd’ I. List of work‘mquiring special inspection: Soils Compllancc Prior to FoOndatton Inspection Struoturrl Concrete Over 2500 PSI 117 Field Welding a High Strength Bolting U Expansfon/Epoxy Anchors [TI Prestressed Conorete u Structural Masonry Iz] Doslgnor Specifled 2. Narne(s) of indfvidurl(s) Of fiirm($) responsible for the special inspections Iisted above: 3. Dutier of the Special inspectors for the work listed above: Carlsbad 99-1972 June 8,1999 vryrl MU LTI PLI E R Room addition 209 20,482 (City valuation) VALUATION AND PLAN CHECK FEE TOTAL VALUE JURISDICTION: Carlsbad PLAN CHECK NO.: 99-1972 20,482 PREPARED BY: Sergio Azuela DATE: June 8,1999 BUILDING ADDRESS: 2821 Cacatua St. room addition to a SFD BUILDING OCCUPANCY: R-3 & U-1 TYPE OF CONSTRUCTION: VN Air Conditioning Fire Sprinklers 0 I99 0 I99 Type of Review: Complete Review Structural Only 0 Hourly 0 Repetitive Fee Applicable UBC Building Permit Fee UBC Pian Check Fee a Bldg. Permit Fee by ordinance: $ 209.83 Ix] Plan Check Fee by ordinance: $ 136.39 0 Other: Esgil Pian Review Fee: $ 109.11 Comments: Sheet1 of 1 macvalue.doc 5196 ? ( BUILDING PLANCHECK CHECKLIST DATE: 6 /J- 49 PLANCHECK NO.: CB e- /472 BUILDING ADDRESS: zsz I G4ca-h 54. PROJECT DESCRIPTION: if?.YL *cM D FOR OFFICIAL USE ONLY ENGINEERING AUTHORIZATION TO ISSUE BUILDING PERMIT: / By: Date: r 1 ASSESSOR’S PARCEL NUMBER: 2 17- 37 0 * 26 ENGINEERING DEPARTMENT EST. VALUE: APPROVAL The item you have submitted for review has been approved. The approval is based on plans, information and/or specifications provided in your submittal; therefore any changes to these items after this date, including field modifications, must be reviewed by this office to insure continued conformance with applicable codes. Please review carefully all comments attached, as failure to comply with instructions in this report can result in suspension of permit to build. A Right-of-way permit is required prior to construction of the following improvements: DENIAL Please see the attached report of deficiencies marked with 0. Make necessary corrections to plans or specifications for compliance with applicable codes and standards. Submit corrected plans and/or specifications to this office for review. By: Date: By: Date: By: Date: ATTACHMENTS Dedication Application Dedication Checklist ENGINEERING DEPT. CONTACT PERSON Name: David Rick City of Carlsbad Improvement Application Address: 2075 Las Palmas Dr., Carlsbad, CA 92009 Improvement Checklist Phone: 1619) 438-1 161. ext. 4324 Future Improvement Agreement Grading Permit Application Grading Submittal Checklist CFD INFORMATION Parcel Map No: Lots: Right-of-way Permit Application Recordation: Right-of-way Permit Submittal Checklist and Information Sheet Sewer Fee Information Sheet Carlsbad Tract: A-4 c r BUILDING PLANCHECK CHECKLIST DEDICATION REQUl REM ENTS 5. Dedication for all street Rights-of-way adjacent to the building site and any storm drain or utility easements on the building site is required for all new buildings and for remodels with a value at or exceeding $ , pursuant to Carlsbad Municipal Code Section 18.40.030. 3RDJ FfiNDJ CI Dedication required as follows: Dedication required. Please have a registered Civil Engineer or Land Surveyor prepare the appropriate legal description together with an 8 %" x 11" plat map and submit with a title report. All easement documents must be approved and signed by owner(s) prior to issuance of Building Permit. Attached please find an application form and submittal checklist for the dedication process. Submit the completed application form with the required checklist items and fees to the Engineering Department in person. Applications will not be accept by mail or fax. Dedication completed by: Date: IMPROVEMENT REQUIREMENTS Li CI c1 6a. All needed public improvements upon and adjacent to the building site must be constructed at time of building construction whenever the value of the construction exceeds $ Section 18.40.040. , pursuant to Carlsbad Municipal Code Public improvements required as follows: Attached please find an application form and submittal checklist for the public improvement requirements. A registered Civil Engineer must prepare the appropriate improvement plans and submit them together with the requirements on the attached checklist to the Engineering Department through a separate plan check process. The completed application form and the requirements on the checklist must be submitted in person. Applications by mail or fax are not accepted. Improvement plans must be approved, appropriate securities posted and fees paid prior to issuance of building permit. Improvement Plans signed by: Date: 0 CI 6b. Construction of the public improvements may be deferred pursuant to Carlsbad Municipal Code Section 18.40. Please submit a recent property title report or we may prepare the necessary Future Improvement Agreement. This agreement must be signed, notarized and approved by the City prior to issuance of a Building permit. Future public improvements required as follows: current grant deed on the property and processing fee of !$ so 3 \VASPALMAS\SYS\LIBRARY\ENC\WORMDOCS\CHKLS~ui~~ Plsndwck Ckbl BPwO1 Form DR.h Rev. 815187 BUILDING PLANCHECK CHECKLIST 1stJ 2ndJ 3rdJ CI CI 0 9. A SEWER PERMIT is required concurrent with the building permit issuance. The fee is noted in the fees section on the following page. CI CI CI 10. INDUSTRIAL WASTE PERMIT If your facility is located in the City of Carlsbad sewer service area, you need to contact the Carlsbad Municipal Water District, located at 5950 El Camino Real, Carlsbad, CA 92008. District personnel can provide forms and assistance, and will check to see if your business enterprise is on the EWA Exempt List. You may telephone (760) 438-2722, extension 153, for assistance. Industrial Waste permit accepted by: Date: CI D Cl 11. NPDES PERMIT Complies with the City’s requirements of the National Pollutant Discharge Elimination System (NPDES) permit. The applicant shall provide best management practices to reduce surface pollutants to an acceptable level prior to discharge to sensitive areas. Plans for such improvements shall be approved by the City Engineer prior to issuance of grading or building permit, whichever occurs first. 0 CI D 12. Cl Required fees are attached Cl No fees required 0 CI cl 13. Additional Comments: 5 \~SPALMAS\SYS\LIBRR~NG\~RDWOCS~n~S~u~i~ Plancheck Cklrl EPooO1 Fon DR.doc Rev. 913197 PLANNING DEPARTMENT BUILDING PLAN CHECK REVIEW CHECKLIST Plan Check N Address J(fy5Y CHAP, d- Planner Phone (61 9) 438-1 161, extension $39 Type of Project & Use: GFR Net Project Density: DU/AC Zoning: &- General Plan: . QLV/ Facilities Management Zone: & CFD lin/nrrt\ # Date of participation: Remaining net dev acres: APN: u ac5-370-3L Circle One - (For non-residential development: Type of land used created by this permit: 1 Leaend: Item Complete Item Incomplete - Needs your action TYPE Environmental Review Required: YES - NO - DATE OF COMPLETION: Compliance with conditions of approval? If not, state conditions which require action. Conditions of Approval: Discretionary Action Required: APPROVAL/RESO. NO. DATE PROJECT NO. OTHER RELATED CASES: Compliance with conditions or approval? If not, state conditions which require action. Conditions of Approval: TYPE - YES - NO Coastal Zone Assessment/Compliance Project site located in Coastal Zone? YES - NO- CA Coastal Commission Authority? YES - - NO If California Coastal Commission Authority: Contact them at - 31 11 Camino Del Rio North, Suite 200, San Diego CA 92108-1725; (619) 521-8036 Determine status (Coastal Permit Required or Exempt): If NO, complete Coastal Permit Determination Form now. Coastal Permit Determination Form already compieted? YES- NO- Coastal Permit Determination Log #: Follow-Up Actions: 1) Stamp Building Plans as "Exempt" or "Coastal Permit Required" (at minimum Floor Plans). 2) Complete Coastal Permit Determination Log as needed. PR ERRED CONSTRUCTION INSPECTIONS, INC. 488 F RONSON COURT "G" SAN DIEGO, CA 92111 TELEPHONE (858) 576-9110 JOB NO. CERTIFIED INSPECTOR'S WEEKLY REPORT COVERING WORK PERFORMED 0 REINFORCED CONCRETE 0 STRUCT. STEEL ASSEMBLY THE SPECIAL INSPECTOR OF 0 REINFOACED MASONRY 0 DEEP FOUNDATION WHICH REQUIRED APPROVAL BY 0 PRE-STRESSED CONCRETE 0 REINFORCED GYPSUM JOB AWRESS PLAN FILE NUMBER MICHITECT CONSTR. MAT'L. (WE, QRIOE, ETC.) OESW SOURCE OF MFQR STRENQTH DESCRIBE MATZ (MIX DESON. RE-BAR GRADE L WOR.. WELD--. ETC.) GENERAL CONTRACTOR - CERnFlCATlON OF COMPLIANCE: To the best of our knowledge, all of the reported work, Unless othewise noted, substantially complies with approved plan. specifications and applicable sections of the building codes. This report covers the locations of the work inspected only and does not constitute engineering opin ion or project conlrol. -~ - ~. p"" $30 0 0 0 0 0 - lnclusionary Housing Fee required: YES - NO (Effective date of lnclusionary Housing Ordinance - May 21, 1993.) Data Entry Completed? YES - NO- IAPIDs, Activity Maintenance, enter CBX, toolbar, Screens, Housing Fees, Construct Housing YIN, Enter Fee, UPDATE!) Site Plan: 1. Provide a fully dimensional site plan drawn to scale. Show: North arrow, property lines, easements, existing and proposed structures, streets, existing street improvements, right-of-way width, dimensional setbacks and existing topographical lines. 2. Provide legal description of property and assessor's parcel number. Zoning: 1. 2. 3. 4. 5. Setbacks: Front: Interior Side: Street Side: Rear: Required 3 , Shown 35 Required LO ) Shown /o/ lo Shown Required Required &kJ 2 Accessory structure setbacks: Front: Interior Side: Shown Shown Street Side: auired Required aration: Required Shown / I Rear: Shown Shown Lot Coverage: Height: Required - Shown Required bph Shown 72/ 2- 7 Parking: Spaces Required & Shown Guest Spaces Required Shown - Additional Comments OK TO ISSUE AND ENTERED APPROVAL INTO COMPUTER . $.i;h.c DATE 5--7g-i'