HomeMy WebLinkAbout2821 CACATUA ST; ; CB991972; PermitCity of Carlsbad 4 a 10/22/1999 Resident ia I Perm it Permit No:CB991972
Building Inspection Request Line (760) 438-31 01
Job Address:
Permit Type:
Parcel No:
Valuation:
Occupancy Group:
# Dwelling Units:
Bedrooms: Project Title:
2821 CACATUA ST CBAD
RESDNTL SubType: RAD
21 53702600 Lot #: 0 $20,482.00 Construction Type: VN
27 Reference #:
0 Structure Type:
0 Bathrooms: 0
RAD 209 SF-2ND STRY ADDITION
Applicant:
MONTELLO TERRY
Status: ISSUED
Applied: 05/24/1999
Plan Approved: 10/22/1999
Issued: 10/22/1999
Entered By: JM
Inspect Area:
Orig PC#:
Plan Check#:
5360 201'Z2/W 3001 (11 02 2331 Y gt7 Owner:
TRYGSTAD JEAN W C-PRHT
471 5 60TH STREET
SAN DIEGO CA 921 15
61 9-229-0642
Building Permit
Add'l Building Permit Fee
Plan Check
Add'l Plan Check Fee
Plan Check Discount
Strong Motion Fee
Park in Lieu Fee
Park Fee LFM Fee
Bridge Fee
Other Bridge Fee
BTD #2 Fee
BTD #3 Fee
Renewal Fee $0.00
Add'l Renewal Fee $0.00
Other Building Fee $0.00
Pot. Water Con. Fee $0.00
Meter Size Add'l Pot. Water Con. Fee $0.00
Recl. Water Con. Fee $0.00
-"=T"~"CTRICAL TOTAL
MECHANICAL TOTAL
Housing Impact Fee
Housing InLieu Fee
Master Drainage Fee:
Sewer Fee:
TOTAL PERMIT FEES
$20.00
$0.00
$0.00
$0.00
$0.00
$0.00
$368.27
review, set aside, void, or annul their imposition.
CITY OF CARLSBAD
2075 Las Palmas Dr., Carlsbad, CA 92009 (760) 438-1161
APPLICATION
CITY OF CARLSBAD BUILDING DEPARTMENT
2075 Las Palmas Dr., Carlsbad CA 92009
(760) 438- 1 16 1
FOR OFFICE USE ONLY
EST. VAL.
Validated By A/- .
Date
(Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law
[Chapter 9, commendina with Section 7000 of Division 3 of the Business and Professions Code1 or that he is exemDt therefrom, and the basis for the alleaed
8 7 31.5 by any applicant for a permit subjects the applicant to a civil penalty of not.more than five hundred dollars IS5001). - 7&0-?W,y
Nahd Address City Statelzip Telephone #
P. ..
License Class City Business License # &'?&&. F&+y O0-I -79)
'hD Pa& CJA w~@Q-kp 2/. < b flIt\C
Addre& City Statelzip Telephdhe '
State License #
nsation as provided by Section 3700 of the Labor Code, for the performance
of the work for which this permit is issued.
&have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is
issued. My worker's compensa
Insurance Company @.laqe
(THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS [$lo01 OR LESS)
0 CERTIFICATE OF EXEMPTION: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as
to become subject to the Workers' Compensation Laws of California.
WARNING: Failure to secure workers' compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred
Expiration Date \ 1 - 23 -09
I hereby affirm that I am exempt from the Contractor's License Law for the following reason:
0 I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale
(Sec. 7044. Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does
such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is
sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale).
I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The
Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s1 licensed
pursuant to the Contractor's License Law).
0
1.
2.
3.
4.
number I contractors license number):
5.
of work):
I am exempt under Section
I personally plan to provide the major labor and materials for construction of the proposed property improvement. 0 YES
I (have I have not) signed an application for a building permit for the proposed work.
I have contracted with the following person (firm) to provide the proposed construction (include name I address I phone number / contractors license number):
I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name I address I phone
I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name I address I phone number I type
Business and Professions Code for this reason:
ON0
PROPERTY OWNER SIGNATURE DATE
IS SECTION FOR
Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention
program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? 0 YES 0 NO
Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? 0 YES 0 NO
Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? 0 YES 0 NO
IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE
REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT.
DING AGE
I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097(i) Civil Code).
LENDER'S NAME LENDER'S ADDRESS
I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all
City ordinances and State laws relating to building construction. I hereby authorize representatives of the City of Carlsbad to enter upon the above mentioned
property for inspection purposes. I ALSO AGREE TO SAVE. INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES,
JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT.
OSHA An OSHA permit is required for excavations over 5'0" deep and demolition or construction of structures over 3 stories in height.
EXPIRATION: Every permit
work authorized by such permit is n
or abandoned at any time af
APPLICANT'S SIGNATURE DATE
limitation and become null and void if the building or
e date of such permit or if the building or
ys (Section 106.4.4 Uniform Building Code).
WHITE: File YELLOW: Applicant PINK: Finance
FROM : SAF CBNST FW NO. : 7687434118 Oct. 28 1999 09:55FM p5
LO -\+%%
I'
,
City of Carlsbad Bldg Inspection Request
For: 4/13/2000
Permit# CB991972 Inspector Assignment: PD
Title: RAD 209 SF-2ND STRY ADDITION
Description:
Type: RESDNTL SubType: RAD
Job Address: 2821 CACATUA ST
Suite: Lot
Location:
APPLICANT MONTELLO TERRY
Owner: TRYGSTAD JEAN W
Remarks:
Total Time:
CD Description
19 Final Structural
29 Final Plumbing
39 Final Electrical
49 Final Mechanical
0
Phone: 76074341 18
Requested By: STEVE
Entered By: CHRISTINE
Act Comments
I t
Associated PCRs
Inspection History
Date Description
3/9/2000 13 Shear PaneWHD’s
3/9/2000 17 Interior LathlDrywall
3/6/2000 13 Shear PaneMHD’s
2/16/2000 17 Interior LathlDrywall
2/8/2000 13 Shear PanelslHD’s
2/8/2000 44 RoughlDucWDampers
1/24/2000 16 Insulation
1/24/2000 18 Exterior LathlDrywall
1/21/2000 16 Insulation
1/21/2000 18 Exterior LathlDrywall
1/14/2000 34 Rough Electric
12/29/1999 15 Roof/Reroof
12/22/1999 14 Frarne/Steel/BoltingNlding
11/15/1999 11 Ftg/Foundation/Piers
11/12/1999 11 Ftg/Foundation/Piers
Act lnsp
AP PD
AP PD
PA PD
PA PD
PA PD
PA PD
AP PD
AP PD
CA PD
CA PD
PA PD
AP PD
AP SR
AP SR
CO SR
Comments
INTERIOR
UPSTAI RS
FOR SIDING
SUB FLOOR FRAME ONLY
ND TO MOVE HD2A &WRAP PLMBING IN FTG.
NEED SPECIAL INSPECTION ON DH-5A
I CONSTRUCTION INSPECTIONS, INC.
SAN DIEGO, CA 92111 TELEPHONE (858) 576-9110
APPROVAL BY
CERTIFICATION OF COMPLIANCE: To the best of our knowledge, all Of the reported work, unless otherwise noted, substantially complies with approved pian:
specifications and applicable sections of the building codes. This report covers the locations Of the work inspected only and does not constitute engineering opin.
ion or project control.
EsGil CorDoration
In %aTtneTSfiip wit6 ~overnrnent for BuiHing Safety
DATE: October 7, 1999
J U Rl SDl CTl ON : Carlsbad REVIEWER
PLAN CHECK NO.: 99-1972 SET: I11
PROJECT ADDRESS: 2821 Cacatua St.
PROJECT NAME: Room addition for Gene Trygstad residence (SFD)
0 FILE
o
w
0
0
0
0
w
0
w
The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes.
The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff.
The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
The check list transmitted herewith is for your information. The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck.
The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
The applicant's copy of the check list has been sent to:
Esgil Corporation staff did not advise the applicant that the plan check has been completed.
Esgil Corporation staff did advise the applicant that the plan check has been completed.
Person contacted: Telephone #:
Date contacted: (by: 1 Fax #:
REMARKS: Applicant shall provide a "Special Inspection Program" to the Building Official.
Mail Telephone Fax In Person
By: Sergio Azuela Enclosures:
Esgil Corporation
GA MB EJ PC 9/29 trnsmtl .dot
9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858) 560-1468 Fax (858) 560-1576
- EsGil - Corporation
In Partnership with +jovrrnnrcnt for BuiHing Safety
DATE: September 15, 1999
JURISDICTION : Carlsbad
PLAN CHECK NO.: 99-1972
P APPLICANT
PLAN REVIEWER
0 FILE
6sa
SET: I1
PROJECT ADDRESS: 2821 Cacatua St.
PROJECT NAME: Room addition for Gene Trygstad residence (SFD)
0 The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes.
0 The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff.
0 The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
The check list transmitted herewith is for your information. The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck.
0 The applicant's copy of the check list is enclosed for the jurisdiction to fowvard to the applicant
contact person.
The applicant's copy of the check list has been sent to:
Terry Montello
4715 60th St., San Diego, CA 921 I5
Esgil Corporation staff did not advise the applicant that the plan check has been completed.
0 Esgil Corporation staff did advise the applicant that the plan check has been completed.
Person contacted: Telephone #:
Date contacted: (by: 1 Fax #:
Mail Telephone Fax In Person 0 REMARKS:
By: Sergio Azuela Enclosures:
Esgil Corporation 0 GA 0 MB 0 EJ 0 PC 917
0
tmsmtl.dot
9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858) 560-1468 + Fax (858) 560-1576
Carlsbad 99-1972 I1
September 15, 1999
RECHECK PLAN CORRECTION LIST
PROJECT ADDRESS: 2821 Cacatua St. SET: I1
DATE PLAN RECEIVED BY
ESGIL CORPORATION: 9R
REVIEWED BY: Sercrio Azuela
DATE RECHECK COMPLETED:
September 15, 1999
FOREWORD (PLEASE READ):
This plan review is limited to the technical requirements contained in the Uniform Building Code,
Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws
regulating energy conservation, noise attenuation and disabled access. This plan review is
based on regulations enforced by the Building Department. You may have other corrections
based on laws and ordinances enforced by the Planning Department, Engineering Department
or other departments.
The following items listed need clarification, modification or change. All items must be satisfied
before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3,
1997 Uniform Building Code, the approval of the plans does not permit the violation of any
state, county or city law.
A. Please make all corrections on the original tracings and submit two new sets of prints to:
Esgil Corp. or to the bldg. dept. of the juris.
B. To facilitate rechecking, please identify, next to each item, the sheet of the plans upon
which each correction on this sheet has been made and return this sheet with the
revised plans.
C. The following items have not been resolved from the previous plan reviews. The original
correction number has been given for your reference. In case you did not keep a copy of
the prior correction list, we have enclosed those pages containing the outstanding
corrections. Please contact me if you have any questions regarding these items.
D. Please indicate here if any changes have been made to the plgns that are not a result of
corrections from this list. If there are other changes, please briefly describe them and where
they are located on the plans. Have changes been made not resulting from this list?
OYes ONo
Carlsbad 99- 1972 I1
September 15, 1999
1. Please make all corrections on the original tracings, as requested in the correction
list.
Submit three sets of plans for comrnerciaVindustriaI projects (two sets of plans for
residential projects). For expeditious processing, corrected sets can be submitted
in one of two ways:
1. Deliver all corrected sets of plans and calculations/reports directly to the
City of Carlsbad Building Department, 2075 Las Palmas Drive, Carlsbad, CA
92009, (760) 438-1 161. The City will route the plans to EsGil Corporation and the
Carlsbad Planning, Engineering and Fire Departments.
2. Bring one corrected set of plans and calculationslreports to EsGil
Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (619)
560-1 468. Deliver all remaining sets of plans and calculations/reports directly to
the City of Carlsbad Building Department for routing to their Planning, Engineering
and Fire Departments.
NOTE: Plans that are submitted directly to EsGil Corporation only will not
be reviewed by the City Planning, Engineering and Fire Departments until review
by EsGil Corporation is complete.
4. Please revise the Table of REQUIRED SPECIAL INSPECTIONS to include
the SOILS COMPLIANCE PRIOR TO FOUNDATION INSPECTION as shown
below:
0 REQUIRED SPECIAL INSPECTIONS
In addition to the regular inspections, the following checked items will also require
Special Inspection in accordance with Sec. 1701 of the Uniform Building Code.
ITEM REQUIRED? REMARKS
SOILS COMPLIANCE PRIOR TO YES SOILS REPORT
EXPANSlON/EPOXY ANCHORS YES SHEETS 3 & 5
FOUNDATION INSPECTION
5. Include the SOILS COMPLIANCE PRIOR TO FOUNDATION INSPECTION in
the Special Inspection Program provided. The Building Department will
resolve this correction.
13. From the soils report provided:
0 The soils engineer recommended that he/she review the foundation
excavations. Note on the foundation plan that "Prior to the contractor
requesting a Building Department foundation insphion, the soils
engineer shall advise the building official in writing that:
a)
b)
c)
The building pad was prepared in accordance with the soils report,
The utility trenches have been properly backfilled and compacted,
and
The foundation excavations, the soils expansive characteristics and
bearing capacity conform to the soils report."
Carlsbad 99- 1972 I1
September 15, 1999
0 Provide a letter from the soils engineer confirming that the foundation
plan, grading plan and specifications have been reviewed and that it has
been determined that the recommendations in the soils report are properly
incorporated into the construction documents (required by the soil report
Page 3)-
If you have any questions regarding these plan review items, please contact Sergio
Azuela at Esgil Corporation. Thank you.
.
EsGil Corr>oration
In !Partnership with Government for BuiUing Safety
DATE: June 8, 1999
JURI SDlCTl ON: Carlsbad
PLAN CHECK NO.: 99-1972
a APPLICANT
n PLAN REVIEWER
0 FILE
SET: I
PROJECT ADDRESS: 2821 Cacatua St.
PROJECT NAME: Room addition for Gene Trygstad Residence (SFD)
0
0
0
w
0
w
w
0
0
The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction’s building codes.
The plans transmitted herewith will substantially comply with the jurisdiction’s building codes
when minor deficiencies identified below are resolved and checked by building department staff.
The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
The check list transmitted herewith is for your information. The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck.
The applicant’s copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
The applicant’s copy of the check list has been sent to:
Terry Montello
4715 60th St., San Diego, CA 921 15
Esgil Corporation staff did not advise the applicant that the plan check has been completed.
Esgil Corporation staff did advise the applicant that the plan check has been completed.
Person contacted: Telephone #:
Date contacted: (by: 1 Fax #:
REMARKS:
Mail Telephone Fax In Person
By: Sergio Azuela Enclosures:
Esgil Corporation
GA 0 MB EJ PC 5/27 trnsmtl.dot
9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (619) 560-1468 + Fax (619) 560-1576
Carlsbad 99- 1972
June 8, 1999
PLAN REVIEW CORRECTION LIST
SINGLE FAMILY DWELLINGS AND DUPLEXES
PLAN CHECK NO.: 99-1972 JURISDICTION: Carlsbad
PROJECT ADDRESS: 2821 Cacatua St.
FLOOR AREA: Dwelling addition 209 SF STORIES: 2
HEIGHT: 28 FT
REMARKS:
DATE PLANS RECEIVED BY DATE PLANS RECEIVED BY
JURISDICTION: 5/24/99 ESGIL CORPORATION: 5/27
DATE INITIAL PLAN REVIEW
COMPLETED: June 8, 1999
PLAN REV1 EWER: Sergio Azuela
FOREWORD (PLEASE READ):
This plan review is limited to the technical requirements contained in the Uniform Building Code,
Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws
regulating energy conservation, noise attenuation and access for the disabled. This plan review
is based on regulations enforced by the Building Department. You may have other corrections
based on laws and ordinance by the Planning Department, Engineering Department, Fire
Department or other departments. Clearance from those departments may be required prior to
the issuance of a building permit.
Present California law mandates that residential construction comply with Title 24 and the
following model codes: 1994 UBC (effective 12/28/95), 1994 UPC (effective 12/28/95), 1994
UMC (effective 2/23/96) and 1993 NEC (effective 12/28/95).
The above regulations apply to residential construction, regardless of the code editions adopted
by ordinance.
The following items listed need clarification, modification or change. All items must be satisfied
before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3,
I994 Uniform Building Code, the approval of the plans does not permit the violation of any
state, county or city law.
To speed up the recheck process, please note on this list (or a copv) where each
correction item has been addressed, i.e., plan sheet number, specification section, etc.
Be sure to enclose the marked up list when you submit the revised plans.
LIST NO. 1, GENERAL SINGLE FAMILY DWELLINGS AND DUPLEXES WITHOUT SUPPLEMENTS (1994 UBC) r3forw.dot
Carlsbad 99- 1972
June 8, 1999
PLANS
1. Please make all corrections on the original tracings, as requested in the correction
list.
Submit three sets of plans for commercial/industriaI projects (two sets of plans for
residential projects). For expeditious processing, corrected sets can be submitted
in one of two ways:
1. Deliver all corrected sets of plans and calculations/reports directly to the
City of Carlsbad Building Department, 2075 Las Palmas Drive, Carlsbad, CA
92009, (760) 438-1 161. The City will route the plans to EsGil Corporation and the
Carlsbad Planning, Engineering and Fire Departments.
2. Bring one corrected set of plans and calculationsheports to EsGil
Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 921 23, (61 9)
560-1 468. Deliver all remaining sets of plans and calculationsheports directly to
the City of Carlsbad Building Department for routing to their Planning, Engineering
and Fire Departments.
NOTE: Plans that are submitted directly to EsGil Corporation only will not
be reviewed by the City Planning, Engineering and Fire Departments until review
by EsGil Corporation is complete.
2. Specify on the Title Sheet of the plans the gross floor area of each element of
this project, including dwelling, garage, carport, patio, deck and balcony. Section
106.3.3.
3. Provide a statement on the Title Sheet of the plans that this project shall comply
with Title 24 and the I994 UBC, UMC and UPC and the 1993 NEC.
4. On the cover sheet of the plans, specify any items requiring special inspection, in
a format similar to that shown below. Section 106.3.2.
0 REQUIRED SPECIAL INSPECTIONS
In addition to the regular inspections, the following checked items will also require
Special Inspection in accordance with Sec. 1701 of the Uniform Building Code.
ITEM REQUIRED? REMARKS
SOILS COMPLIANCE PRIOR TO
FO U N DATl 0 N INS PECTlO N
To be rechecked with soils report
* EXPANSIONIEPOXY ANCHORS YES SHEETS 3 & 5
5. When special inspection is required, the architect or engineer of record shall
prepare an inspection program which shall be submitted to the building official for
approval prior to issuance of the building permit. Please review Section
106.3.5. Please complete the attached form.
Carlsbad 99- 1972
June 8, 1999
0 EXITS, STAIRWAYS, AND RAILINGS
Since the proposed addition is located on the second floor the existing
stairways shall be clearly shown on plans to be in full compliance with the
current Code Regulations. Please clearly show on plans full compliance. Full
compliance will be rechecked.
6.
7.
8.
9.
IO.
11.
12.
Required exit doorways shall be not less than 36" in width and not less than 6'8"
in height. Section 1004.6.
Provide stairway and landing details. Sections 1006.3, 1006.1 5 and 1006.2.
a) Maximum rise is 7" and minimum run is 11". When the stairs serves less
than IO occupants, or serves an unoccupied roof, rise may be 8"
maximum and run 9" minimum.
b) Minimum headroom is 6'-8".
c) Minimum width is 36".
Handrails:
a)
b)
Handrails and extensions shall be 34" to 38" above nosing of treads and
be continuous.
All stairs shall have handrails terminating in a newel or safety post.
Section 1006.9.
The handgrip portion of all handrails shall be not less than 1-1/4 inches nor more
than 2 inches in cross-sectional dimension. Handrails projecting from walls shall
have at least I-1/2 inches between the wall and the handrail. Section 1006.9.
ROOFING
Specify on the plans the following information for the roof materials, per Section
106.3.3:
a) Manufacturer's name.
b) Product namelnumber.
c) ICBO approval number, or equal.
Show attic ventilation. Minimum vent area is 1/150 of attic area (or 1/300 of attic
area if at least 50% of the required vent is at least 3 feet above eave vents or
cornice vents). Show area required and area provided. Section 1505.3.
Note on the plans:
corrosion-resistant metal mesh with mesh openings of I /4-inch in dimension."
Section 1505.3.
"Attic ventilation openings shall be covered with
Carlsbad 99- 1972
June 8, 1999
FOUNDATION REQUIREMENTS
13.
14.
15.
16.
Provide a copy of the project soil report prepared by a California licensed
architect or civil engineer. The report shall include foundation design
recommendations based on the engineer's findings and shall comply with UBC
Section 1804.
0 FRAMING
Show location of attic access with a minimum size of 22"x30", unless the
maximum vertical headroom height in the attic is less than 30". Access must be
provided to each separated attic area, shall be located in a hallway or other
readily accessible location and 30" headroom clearance is required above the
opening. Section 1505.1.
CARLSBAD S.F.D. & DUPLEX SUPPLEMENT
All new residential buildings, including additions, require a soils report. Please
submit two copies. Exception: If a room addition is limited to one story and I000
sq. ft. in area, then a soils report is not required. Esgil Corporation will advise the
City to place their soils notice stamp on the plans.
All structures require a Class A roof covering, except room additions. If a room
addition covers all of the existing building (2nd story addition), then the above
exception doesn't apply.
To speed up the review process, note on this list (or a copy) where each correction item
has been addressed, i.e., plan sheet, note or detail number, calculation page, etc.
Please indicate here if any changes have been made to the plans that are not a result
of corrections from this list. If there are other changes, please briefly describe them and
where they are located in the plans.
Have changes been made to the plans not resulting from this correction list? Please
indicate:
Yes 0 No 0
The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake
Drive, Suite 208, San Diego, California 92123; telephone number of 61 9/560-1468, to
perform the plan review for your project. If you have any questions regarding these plan
review items, please contact Sergio Azuela at Esgil Corporation. Thank you.
OCT-13-99 WED 04:49 PM PERMITS IN MOTION
SPECIAL INSPECTION PROGRAM
619 229 0642 P. 02
OCT-13-99 WED 10:54 P, 03
PLAN CHECK NUMBER: ....__OWNER’S NAME:
I, as the owner, or agent of the owner (contractors may & employ the special Inspector), certify that I, or the architecthnginew of record, will be responslbfe for employing the special inspector&) 88 required by Uniform Building Code (UBC) Section 1701.1 for the construction
Signed u(c
Secbon 106.3.5.
I, as the rtngineor/arChlted of record, certify that I have prepared the following special inspection program as requited by UBC Section 106,3.5 for the construction project located at the site listed above.
4~zYd’
I. List of work‘mquiring special inspection:
Soils Compllancc Prior to FoOndatton Inspection Struoturrl Concrete Over 2500 PSI
117 Field Welding a High Strength Bolting U Expansfon/Epoxy Anchors [TI Prestressed Conorete u Structural Masonry Iz] Doslgnor Specifled
2. Narne(s) of indfvidurl(s) Of fiirm($) responsible for the special inspections Iisted above:
3. Dutier of the Special inspectors for the work listed above:
Carlsbad 99-1972
June 8,1999
vryrl
MU LTI PLI E R
Room addition 209 20,482
(City valuation)
VALUATION AND PLAN CHECK FEE
TOTAL VALUE
JURISDICTION: Carlsbad PLAN CHECK NO.: 99-1972
20,482
PREPARED BY: Sergio Azuela DATE: June 8,1999
BUILDING ADDRESS: 2821 Cacatua St. room addition to a SFD
BUILDING OCCUPANCY: R-3 & U-1 TYPE OF CONSTRUCTION: VN
Air Conditioning
Fire Sprinklers
0 I99
0 I99
Type of Review: Complete Review Structural Only 0 Hourly
0 Repetitive Fee Applicable
UBC Building Permit Fee
UBC Pian Check Fee
a Bldg. Permit Fee by ordinance: $ 209.83
Ix] Plan Check Fee by ordinance: $ 136.39
0 Other:
Esgil Pian Review Fee: $ 109.11
Comments:
Sheet1 of 1
macvalue.doc 5196
?
(
BUILDING PLANCHECK CHECKLIST
DATE: 6 /J- 49 PLANCHECK NO.: CB e- /472
BUILDING ADDRESS: zsz I G4ca-h 54.
PROJECT DESCRIPTION: if?.YL *cM
D FOR OFFICIAL USE ONLY
ENGINEERING AUTHORIZATION TO ISSUE BUILDING PERMIT: /
By: Date: r 1
ASSESSOR’S PARCEL NUMBER: 2 17- 37 0 * 26
ENGINEERING DEPARTMENT
EST. VALUE:
APPROVAL
The item you have submitted for review has been
approved. The approval is based on plans,
information and/or specifications provided in your
submittal; therefore any changes to these items after
this date, including field modifications, must be
reviewed by this office to insure continued
conformance with applicable codes. Please review
carefully all comments attached, as failure to comply
with instructions in this report can result in
suspension of permit to build.
A Right-of-way permit is required prior to
construction of the following improvements:
DENIAL
Please see the attached report of deficiencies
marked with 0. Make necessary corrections to plans
or specifications for compliance with applicable
codes and standards. Submit corrected plans and/or
specifications to this office for review.
By: Date:
By: Date:
By: Date:
ATTACHMENTS
Dedication Application
Dedication Checklist
ENGINEERING DEPT. CONTACT PERSON
Name: David Rick
City of Carlsbad
Improvement Application Address: 2075 Las Palmas Dr., Carlsbad, CA 92009
Improvement Checklist Phone: 1619) 438-1 161. ext. 4324
Future Improvement Agreement
Grading Permit Application
Grading Submittal Checklist
CFD INFORMATION
Parcel Map No:
Lots:
Right-of-way Permit Application Recordation:
Right-of-way Permit Submittal Checklist
and Information Sheet
Sewer Fee Information Sheet
Carlsbad Tract:
A-4
c
r BUILDING PLANCHECK CHECKLIST
DEDICATION REQUl REM ENTS
5. Dedication for all street Rights-of-way adjacent to the building site and any storm
drain or utility easements on the building site is required for all new buildings and
for remodels with a value at or exceeding $ , pursuant to Carlsbad
Municipal Code Section 18.40.030.
3RDJ FfiNDJ CI
Dedication required as follows:
Dedication required. Please have a registered Civil Engineer or Land Surveyor prepare the appropriate legal description together with an 8 %" x 11" plat map
and submit with a title report. All easement documents must be approved and signed by owner(s) prior to issuance of Building Permit. Attached please find an application form and submittal checklist for the dedication process. Submit the completed application form with the required checklist items and fees to the
Engineering Department in person. Applications will not be accept by mail or fax.
Dedication completed by: Date:
IMPROVEMENT REQUIREMENTS
Li CI c1 6a. All needed public improvements upon and adjacent to the building site must be constructed at time of building construction whenever the value of the
construction exceeds $ Section 18.40.040. , pursuant to Carlsbad Municipal Code
Public improvements required as follows:
Attached please find an application form and submittal checklist for the public improvement requirements. A registered Civil Engineer must prepare the appropriate improvement plans and submit them together with the requirements on the attached checklist to the Engineering Department through a separate plan check process. The completed application form and the requirements on the checklist must be submitted in person. Applications by mail or fax are not
accepted. Improvement plans must be approved, appropriate securities posted and fees paid prior to issuance of building permit.
Improvement Plans signed by: Date:
0 CI 6b. Construction of the public improvements may be deferred pursuant to Carlsbad
Municipal Code Section 18.40. Please submit a recent property title report or
we may prepare the necessary Future Improvement Agreement. This agreement
must be signed, notarized and approved by the City prior to issuance of a
Building permit.
Future public improvements required as follows:
current grant deed on the property and processing fee of !$ so
3 \VASPALMAS\SYS\LIBRARY\ENC\WORMDOCS\CHKLS~ui~~ Plsndwck Ckbl BPwO1 Form DR.h Rev. 815187
BUILDING PLANCHECK CHECKLIST
1stJ 2ndJ 3rdJ
CI CI 0 9. A SEWER PERMIT is required concurrent with the building permit issuance. The
fee is noted in the fees section on the following page.
CI CI CI 10. INDUSTRIAL WASTE PERMIT If your facility is located in the City of Carlsbad
sewer service area, you need to contact the Carlsbad Municipal Water District,
located at 5950 El Camino Real, Carlsbad, CA 92008. District personnel can
provide forms and assistance, and will check to see if your business enterprise is
on the EWA Exempt List. You may telephone (760) 438-2722, extension 153, for
assistance.
Industrial Waste permit accepted by:
Date:
CI D Cl 11. NPDES PERMIT
Complies with the City’s requirements of the National Pollutant Discharge
Elimination System (NPDES) permit. The applicant shall provide best
management practices to reduce surface pollutants to an acceptable level prior to
discharge to sensitive areas. Plans for such improvements shall be approved by
the City Engineer prior to issuance of grading or building permit, whichever
occurs first.
0 CI D 12. Cl Required fees are attached
Cl No fees required
0 CI cl 13. Additional Comments:
5 \~SPALMAS\SYS\LIBRR~NG\~RDWOCS~n~S~u~i~ Plancheck Cklrl EPooO1 Fon DR.doc
Rev. 913197
PLANNING DEPARTMENT
BUILDING PLAN CHECK REVIEW CHECKLIST
Plan Check N Address J(fy5Y CHAP, d-
Planner Phone (61 9) 438-1 161, extension $39
Type of Project & Use: GFR Net Project Density: DU/AC
Zoning: &- General Plan: . QLV/ Facilities Management Zone: &
CFD lin/nrrt\ # Date of participation: Remaining net dev acres:
APN: u ac5-370-3L
Circle One -
(For non-residential development: Type of land used created by
this permit: 1
Leaend: Item Complete Item Incomplete - Needs your action
TYPE Environmental Review Required: YES - NO -
DATE OF COMPLETION:
Compliance with conditions of approval? If not, state conditions which require action.
Conditions of Approval:
Discretionary Action Required:
APPROVAL/RESO. NO. DATE
PROJECT NO.
OTHER RELATED CASES:
Compliance with conditions or approval? If not, state conditions which require action.
Conditions of Approval:
TYPE - YES - NO
Coastal Zone Assessment/Compliance
Project site located in Coastal Zone? YES - NO-
CA Coastal Commission Authority? YES - - NO
If California Coastal Commission Authority: Contact them at - 31 11 Camino Del Rio North, Suite
200, San Diego CA 92108-1725; (619) 521-8036
Determine status (Coastal Permit Required or Exempt):
If NO, complete Coastal Permit Determination Form now.
Coastal Permit Determination Form already compieted? YES- NO-
Coastal Permit Determination Log #:
Follow-Up Actions:
1) Stamp Building Plans as "Exempt" or "Coastal Permit Required" (at minimum
Floor Plans).
2) Complete Coastal Permit Determination Log as needed.
PR ERRED CONSTRUCTION INSPECTIONS, INC.
488 F RONSON COURT "G"
SAN DIEGO, CA 92111 TELEPHONE (858) 576-9110
JOB NO. CERTIFIED INSPECTOR'S WEEKLY REPORT
COVERING WORK PERFORMED 0 REINFORCED CONCRETE 0 STRUCT. STEEL ASSEMBLY
THE SPECIAL INSPECTOR OF 0 REINFOACED MASONRY 0 DEEP FOUNDATION
WHICH REQUIRED APPROVAL BY 0 PRE-STRESSED CONCRETE 0 REINFORCED GYPSUM
JOB AWRESS PLAN FILE NUMBER
MICHITECT
CONSTR. MAT'L. (WE, QRIOE, ETC.) OESW SOURCE OF MFQR STRENQTH
DESCRIBE MATZ (MIX DESON. RE-BAR GRADE L WOR.. WELD--. ETC.) GENERAL CONTRACTOR -
CERnFlCATlON OF COMPLIANCE: To the best of our knowledge, all of the reported work, Unless othewise noted, substantially complies with approved plan.
specifications and applicable sections of the building codes. This report covers the locations of the work inspected only and does not constitute engineering opin
ion or project conlrol. -~ - ~.
p""
$30
0
0
0
0
0
- lnclusionary Housing Fee required: YES - NO
(Effective date of lnclusionary Housing Ordinance - May 21, 1993.)
Data Entry Completed? YES - NO- IAPIDs, Activity Maintenance, enter CBX, toolbar, Screens, Housing Fees, Construct Housing YIN, Enter Fee, UPDATE!)
Site Plan:
1. Provide a fully dimensional site plan drawn to scale. Show: North arrow,
property lines, easements, existing and proposed structures, streets, existing
street improvements, right-of-way width, dimensional setbacks and existing
topographical lines.
2. Provide legal description of property and assessor's parcel number.
Zoning:
1.
2.
3.
4.
5.
Setbacks:
Front:
Interior Side:
Street Side:
Rear:
Required 3 , Shown 35
Required LO ) Shown /o/
lo
Shown
Required Required &kJ 2
Accessory structure setbacks:
Front:
Interior Side:
Shown
Shown
Street Side: auired
Required
aration: Required Shown
/ I
Rear:
Shown
Shown
Lot Coverage:
Height:
Required - Shown
Required bph Shown 72/
2-
7
Parking: Spaces Required & Shown
Guest Spaces Required Shown -
Additional Comments
OK TO ISSUE AND ENTERED APPROVAL INTO COMPUTER . $.i;h.c DATE 5--7g-i'