HomeMy WebLinkAbout2830 CAZADERO DR; ; CB072573; Permit08-14-2008
Job Address
Permit Type
Parcel No
Valuation
Occupancy Group
# Dwelling Units
Bedrooms
Project Title
City of Carlsbad
1635 Faraday Av Carlsbad, CA 92008
Residential Permit Permit No CB072573
Building Inspection Request Line (760) 602-2725
2830 CAZADERO DR CBAD
RESDNTL Sub Type RAD
2153204000 Lot# 0
$0 00 Construction Type NEW
Reference #
0 Structure Type
0 Bathrooms 0
ZEZELJ RES- CONVERT SFD TO
CARE FACILITY NON AMBULATORY.6 OR LESS
Status
Applied
Entered By
Plan Approved
Issued
Inspect Area
Ong PC#
Plan Check*
2007
LSM
Applicant
ZEZELJ FAMILY TRUST 01-30-04
2807LUCIERNAGAST
CARLSBAD CA 92009
Owner
ZEZELJ FAMILY TRUST 01-30-04
2807 LUCIERNAGA SI
CARLSBAD CA 92009
Building Permit
Add'l Building Permit Fee
Plan Check
Add'l Plan Check Fee
Plan Check Discount
Strong Motion Fee
Park in Lieu Fee
Park Fee
LFM Fee
Bridge Fee
Other Bridge Fee
BTD #2 Fee
BTD #3 Fee
Renewal Fee
Add'l Renewal Fee
Other Building Fee
HMP Fee
Pot Water Con Fee
Meter Size
Add'l Pot Water Con Fee
Reel Water Con Fee
$0 00 Meter Size
$0 00 Add'l Reel Water Con Fee
$0 00 Meter Fee
$360 00 SDCWA Fee
$0 00 CFD Payoff Fee
$100 PFF (3105540)
$0 00 PFF (4305540)
$000 License Tax (3104193)
$000 License Tax (4304193)
$000 Traffic Impact Fee (3105541)
$0 00 Traffic Impact Fee (4305541)
$0 00 Sidewalk Fee
$0 00 PLUMBING TOTAL
$0 00 ELECTRICAL TO! AL
$0 00 MECHANICAL TOTAL
$0 00 Housing Impact Fee
$0 00 Housing InLieu Fee
$0 00 Housing Credit Fee
Master Drainage Fee
$0 00 Sewer Fee
$0 00 Additional Fees
TOTAL PERMIT FEES
$000
$000
$000
$000
$000
$000
$000
$000
$000
$000
$000
$000
$000
$000
$000
$000
$000
$000
$000
$000
$361 00
Total Fees $361 00 Total Payments To Date $0 00 Balance Due $361 00
Inspector
FINAL APPROVAL
Date Clearance
NOTICE Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively
referred to as "fees/exactions" You have 90 days from the date this permit was issued to protest imposition of these fees/exactions If you protest them, you must
follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for
processing in accordance with Carlsbad Municipal Code Section 3 32 030 Failure to timely follow that procedure will bar any subsequent legal action to attack,
review, set aside, void, or annul their imposition
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity
changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project NOR DOES IT APPLY to any
fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired
City of Carlsbad
1635 Faraday Ave , Carlsbad, CA 92008
760-602-2717/2718/2719
Fax 760-602-8558
Building Permit Application
Plan Check No.
Est. Value
Plan Ck. Deposit
Date (0/5/0*7
SUITE#/SPACE#/UNIT#
# BATHROOMS ['TENANT BUSINESS NAME
(Sec 70315 Business and Professions Code Any City or County which requires a permit to construct, alter improve demolish or repair any structure prior to its issuance also requires the applicant for such permit to file a signed statement that he islicensed pursuant to the provisions of the Contractor s License Law (Chapter 9 commending with Section 7000 of Division 3 of the Business and Professions Code) or that he is exempt therefrom and the basis for the alleged exemption Any violation ofSection 70315 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars {J500})
Workers' Compensation Declaration / hereby affirm under penalty of perjury one of the following declarations
O I have and will maintain a certificate of consent to self insure for workers compensation as provided by Section 3700 of the Labor Code for the performance of the work for which this permit is issued
LTI I have and will maintain workers' compensation as required by Section 3700 of the Labor Code for the performance of the work for which this permit is issued My workers compensation insurance carrier and policy
number are Insurance Co Policy No Expiration Date
This section need not be completed if the permit is for one hundred dollars ($100) or less
LTI Certificate of Exemption I certify that in the performance of the work for which this permit is issued I shall not employ any person in any manner so as to become subject to the Workers Compensation Laws of
California WARNING Failure to secure workers' compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars (&100.000), in
addition to the cost of compensation, damages as provided for in Section 3706 of the Labor code, interest and attorney's fees
VST CONTRACTOR SIGNATURE Q(jl/A/t!%- &C< L 0 T.DATE /Q 'if-
/ hereby affirm that I am exempt from Contractor s License Law for the following reason
n I as owner of the property or my employees with wages as their sole compensation will do the work and the structure is not intended or offered for sale (Sec 7044 Business and Professions Code The Contractor s
License Law does not apply to an owner of property who builds or improves thereon and who does such work himself or through his own employees provided that such improvements are not intended or offered for
sale If however the building or improvement is sold within one year of completion the owner builder will have the burden of proving that he did not build or improve for the purpose of sale)
n I as owner of the property am exclusively contracting with licensed contractors to construct the project (Sec 7044 Business and Professions Code The Contractor s License Law does not apply to an owner of
property who builds or improves thereon and contracts for such projects with contractor(s) licensed pursuant to the Contractor s License Law)
O I am exempt under Section Business and Professions Code for this reason
1 I personally plan to provide the major labor and materials for construction of the proposed property improvement Cl Yes CI No /•"
2 I (have / have not) signed an application for a building permit for the proposed work
3 I have contracted with the following person (firm) to provide the proposed construction (include name address / phone / contractors license number)
4 I plan to provide portions of the work but I have hired the following person to coordinate supervise and provide the major work (include name / address / phone / contractors license number)
5 I will provide some of the work but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone / type of work)
I ^PROPERTY OWNER SIGNATURE DATE 200*7
Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505 25533 or 25534 of the
Presley Tanner Hazardous Substance Account Act7 D Yes i^Jo
Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district' d Yes
Is the facility to be constructed wilhm 1 000 feet of the outer boundary of a school site7 O Yes d No
IF ANY OF THE ANSWERS ARE YES, /
EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT
I hereby affirm that there is a construction lending agency for the performance of the work this permit is issued (Sec 3097 i'i) Civil Code)
Lender s Name Lender's Address
1
| I certify that I have read the application and state thatthe above information iscorrect and that the information on the plans is accurate I agree tocomply with all Cityordinancesand State laws relating to building construction i
Uiereby authorize representative of the City of Carlsbad to enter upon the above mentioned property for inspection purposes I ALSO AGREE TO SAVE INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD
AGAINST ALL LIABILITIES, JUDGMENTS. COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT
OSHA An OSHA permit is required for excavations over 5 0 deep and demolition or construction of structures over 3 stones in height
EXPIRATION Every permit issued by the Building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authonzed by such permit is not commenced within
180 days from the date of such perniit or if the building or work authonzed by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days (Section 106 4 4 Uniform Building Code)
^APPLICANT'S SIGNATURE ^-^sTg^^^ ] "5 •) DATE /Q -^ /* -
I
City of Carlsbad
Bui ding Department
August 6, 2008
MIKE ZEZEU
2807 LUCIERNAGA ST
CARLSBAD CA 92009
RE
APPLICATION DATE
PLAN CHECK #
ADDRESS
EXPIRATION DATE
PERMIT TYPE
DESCRIPTION
10/05/2007
CB072573
2830 CAZADERO DR
10/04/2008
RES
CONVERT SFD TO RESIDENTIAL CARE FAC
You applied to have your plans checked on the date noted above To date, the related building
permit has not been obtained The original plan review application will expire as no building
permit has been issued
Plans submitted and not retrieved from the building department prior to the plan check
expiration date noted above will be destroyed
The provisions of sections 304 (d) of the Uniform Building Code state
"Section 304 9d) Expiration of Plan Review
Applications for which no permit is issued within one year following the date of
application shall expire by limitation, and plans and other data submitted for review
may thereafter be returned to the applicant or destroyed by the Building Official
In order to renew action on an application after expiration, the applicant shall resubmit
plans and pay a new plan review fee "
In order to provide better service, please indicate your handling choice for the plans originally
submitted and return this letter to the Building Department
Project Abandoned -1 will pick up the plans within 10 days
Project Abandoned - Plans may be destroyed
If you have any questions, please contact the Building Department at (760) 602-2719
Building Department
CC
1635 Faraday Avenue • Carlsbad, CA 92008-7314 • (760) 602-2700
Building Counter • (760) 6O2-2719 • FAX ('760) 602-8558
EsGil Corporation
In (Partnership with government forQuitting Safety
DATE 01/07/2008 a APPLICANT
"JURIS
JURISDICTION City of Carlsbad
a FILE
PLAN CHECK NO O7-2573 SET II
PROJECT ADDRESS 2830 Cazadero Dr
PROJECT NAME 2832 Cazadero Dr Change of Occupancy R-3 to R-
The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes
The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff
The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck
XI The check list transmitted herewith is for your information The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck
The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person
The applicant's copy of the check list has been sent to
2807 Luciernaga St, Carlsbad, CA 92009
Esgil Corporation staff did not advise the applicant that the plan check has been completed
XI Esgil Corporation staff did advise the applicant that the plan check has been completed
Person contacted MikaZerzelj Telephone* (760)803-8188
Date contacted / 17(0°(b\/M£) Fax # 760-438-4838
Mail y Telephone Fax \/\n Person
REMARKS
By Aaron Goodman Enclosures
EsGil Corporation
D GA D MB D EJ D PC 12/28/2007
9320 Chesapeake Drive, Suite 208 * San Diego, California 92123 4 (858)560-1468 *• Fax (858) 560-1576
"City of Carlsbad O7-2573
01/07/2008
PLAN REVIEW CORRECTION LIST
TENANT IMPROVEMENTS
PLAN CHECK NO 07-2573
OCCUPANCY R-
TYPE OF CONSTRUCTION V-N
ALLOWABLE FLOOR AREA
SPRINKLERS'? No
REMARKS
DATE PLANS RECEIVED BY
JURISDICTION 10/5/07
DATE INITIAL PLAN REVIEW
COMPLETED 01/07/2008
JURISDICTION City of Carlsbad
USE Non-ambulatory Residence
ACTUAL AREA sf
STORIES 1
HEIGHT
OCCUPANT LOAD
DATE PLANS RECEIVED BY
ESGIL CORPORATION 12/28/2007
PLAN REVIEWER Aaron Goodman
FOREWORD (PLEASE READ):
This plan review is limited to the technical requirements contained in the Uniform Building Code,
Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws
regulating energy conservation, noise attenuation and access for the disabled This plan review
is based on regulations enforced by the Building Department You may have other corrections
based on laws and ordinances enforced by the Planning Department, Engineering Department,
Fire Department or other departments Clearance from those departments may be required
prior to the issuance of a building permit
Code sections cited are based on the 2001 CBC, which adopts the 1997 UBC
The following items listed need clarification, modification or change All items must be satisfied
before the plans will be in conformance with the cited codes and regulations Per Sec 106 4 3,
1997 Uniform Building Code, the approval of the plans does not permit the violation of any state,
county or city law
To speed up the recheck process, please note on this list (or a copy) where each
correction item has been addressed, i e., plan sheet number, specification section, etc.
Be sure to enclose the marked up list when you submit the revised plans.
TENANT IMPROVEMENTS WITHOUT SPECIFIC ENERGY DATA OR POLICY SUPPLEMENTS (1997UBC)tiforw dot
' City of Carlsbad O7-2573
O1/07/2OO8
Important Notice Regarding the 2007 CBC
If you are an architect, engineer, designer or contractor that performs work within
the State of California, please be advised that a new building code will take effect
on January 1, 2008 The new building code is based on the 2006 International
Building Code (IBC) and it is significantly different than the Uniform Building
Code (UBC)
All plan review applications submitted after December 31. 2007 will be required
to comply with the new code
The 2007 CBC is currently available for purchase directly from the International
Code Council, at www iccsafe org
Please make all corrections on the original tracings, as requested in the
correction list Submit three sets of plans for commercial/industrial projects
(two sets of plans for residential projects) For expeditious processing,
corrected sets can be submitted in one of two ways
1 Deliver all corrected sets of plans and calculations/reports directly to the
City of Carlsbad Building Department, 1635 Faiaday Ave , Carlsbad, CA
92008, (760) 602-2700 The City will route the plans to EsGil Corporation
and the Carlsbad Planning, Engineering and Fire Departments
2 Bring one corrected set of plans and calculations/reports to EsGil
Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123,
(858) 560-1468 Deliver all remaining sets of plans and calculations/reports
directly to the City of Carlsbad Building Department for routing to their
Planning, Engineering and Fire Departments
NOTE Plans that are submitted directly to EsGil Corporation only will not
be reviewed by the City Planning, Engineering and Fire Departments until
review by EsGil Corporation is complete
This review is for the change of occupancy from an R-3 to an R-2 1 1 the
building addition was reviewed under 07-0898 Changes to the building
structural as a result of this review will require Further structural review
1. Clearly define the use of each area of this building. The application
says that a portion, if not all, of this building which appears now to
be two dwelling units will be an adult care facility. Clearly show the
area of the adult care facility. If a portion of this building is not part
of the adult care facility, clearly show what the use of such areas
shall be.
When the character of the occupancy or use changes within a building,
the building must be made to comply with current Building Code
requirements for the new occupancy Please provide complete details to
show the building will comply Section 3405
' 'City of Carlsbad O7-2573
O1/07/2008
On the title sheet:
a) Specify the Group of Occupancy, Unit 1
b) Specify the Group of Occupancy, Unit 2
Provide the square footage of the adult care area(s), Unit 1
c) Provide the square footage of the adult care area(s), Unit 2
d) Provide the occupant load, per sleeping room, of the adult care
area(s), Unit 1
e) Provide the occupant load, per sleeping room, of the adult care
area(s), Unit 2
f) Provide the square footage of the areas not included in the adult
care facility, Unit 1
g) Provide the square footage of the areas not included in the adult
care facility, Unit 2
Show the location of the "Pull Station" on the plans.
In addition to the smoke detector required by section 310 9 Group R
Division 2 1 1 occupancies shall be provided with at least one manual pull
station at a location approved by the authority having jurisdiction Such
pull station shall actuate a distinctive fire alarm signal which shall be
audible through out the facility Section 310 10 2 See also 310.10
exception 2a.
!
To speed up the review process, note on this list (or a copy) where each
correction item has been addressed, i e , plan sheet, note or detail
number, calculation page, etc
Please indicate here if any changes have been made to the plans that are
not a result of corrections from this list If there are other changes, please
briefly describe them and where they are located in the plans
Have changes been made to the plans not resulting from this correction
list? Please indicate
Yes Q No a
The jurisdiction has contracted with Esgil Corporation located at 9320
Chesapeake Drive, Suite 208, San Diego, California 92123, telephone
number of 858/560-1468, to perform the plan review for your project If
you have any questions regarding these plan review items, please contact
Aaron Goodman at Esgil Corporation Thank you
EsGil Corporation
In (PartnersHip -with government for (Building Safety
DATE 10/16/07 LLAPPJUCANT
JURISDICTION City of Carlsbad Q PLAN REVIEWER
a FILE
PLAN CHECK NO 07-2573 SET I
PROJECT ADDRESS 2830 Cazadero Dr
PROJECT NAME 2832 Cazadero Dr Change of Occupancy R-3 to R-2.1.1
The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes
The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff
The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck
XI The check list transmitted herewith is for your information The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck
The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person
XI The applicant's copy of the check list has been sent to
Mike Zerzelj
2807 Luciernaga St, Carlsbad, CA 92009
Esgil Corporation staff did not advise the applicant that the plan check has been completed
XI Esgil Corporation staff did advise the applicant that the plan check has been completed
Person contacted Mike Zerzelj Telephone # (760) 803-8188
Date contacted Wf7/t>7 (by^#9 Fax # 760-438-4838
Mail Telephone \/ Fax /In Person
REMARKS
By Doug Moody Enclosures
Esgil Corporation
D GA D MB D EJ D PC 10/8/07
9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858)560-1468 •* Fax (858) 560-1576
City of Carlsbad 07-2573
10/16/07
PLAN REVIEW CORRECTION LIST
TENANT IMPROVEMENTS
PLAN CHECK NO 07-2573
OCCUPANCY R-2 1 1
TYPE OF CONSTRUCTION VN
ALLOWABLE FLOOR AREA
SPRINKLERS'? No
REMARKS
DATE PLANS RECEIVED BY
JURISDICTION 10/5/07
DATE INITIAL PLAN REVIEW
COMPLETED 10/16/07
JURISDICTION City of Carlsbad
USE Non-ambulatory Residence
ACTUAL AREA 1221sf
STORIES 1
HEIGHT
OCCUPANT LOAD 6
DATE PLANS RECEIVED BY
ESGIL CORPORATION 10/8/07
PLAN REVIEWER Doug Moody
FOREWORD (PLEASE READ):
This plan review is limited to the technical requirements contained in the Uniform Building Code,
Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws
regulating energy conservation, noise attenuation and access for the disabled This plan review
is based on regulations enforced by the Building Department You may have other corrections
based on laws and ordinances enforced by the Planning Department, Engineering Department,
Fire Department or other departments Clearance from those departments may be required
prior to the issuance of a building permit
Code sections cited are based on the 2001 CBC, which adopts the 1997 UBC
The following items listed need clarification, modification or change All items must be satisfied
before the plans will be in conformance with the cited codes and regulations Per Sec 106 4 3,
1997 Uniform Building Code, the approval of the plans does not permit the violation of any
state, county or city law
To speed up the recheck process, please note on this list (or a copy) where each
correction item has been addressed, i.e , plan sheet number, specification section, etc
Be sure to enclose the marked up list when you submit the revised plans.
TENANT IMPROVEMENTS WITHOUT SPECIFIC ENERGY DATA OR POLICY SUPPLEMENTS (1997UBC)tiforw dot
City of Carlsbad O7-2573
10/16/07
Important Notice Regarding the 2007 CBC
If you are an architect, engineer, designer or contractor that performs work within the
State of California, please be advised that a new building code will take effect on
January 1, 2008 The new building code is based on the 2006 International Building
Code (IBC) and it is significantly different than the Uniform Building Code (UBC)
All plan review applications submitted after December 31, 2007 will be required to
comply with the new code
The 2007 CBC is currently available for purchase directly from the International Code
Council, at www iccsafe org
Please make all corrections on the original tracings, as requested in the correction
list Submit three sets of plans for commercial/industrial projects (two sets of plans
for residential projects) For expeditious processing, corrected sets can be
submitted in one of two ways
1 Deliver all corrected sets of plans and calculations/reports directly to the City of
Carlsbad Building Department, 1635 Faraday Ave , Carlsbad, CA 92008, (760)
602-2700 The City will route the plans to EsGil Corporation and the Carlsbad
Planning, Engineering and Fire Departments
2 Bring one corrected set of plans and calculations/reports to EsGil Corporation,
9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468
Deliver all remaining sets of plans and calculations/reports directly to the City of
Carlsbad Building Department for routing to then Planning, Engineering and Fire
Departments
NOTE Plans that are submitted directly to EsGil Corporation only will not be
reviewed by the City Planning, Engineering and Fire Departments until review by
EsGil Corporation is complete
This review is for the change of occupancy from an R-3 to an R-2 1 1 the
building addition was reviewed under 07-0898 Changes to the building structural
as a result of this review will require further structural review
1 When the character of the occupancy or use changes within a building, the
building must be made to comply with current Building Code requirements for the
new occupancy Please provide complete details to show the building will
comply Section 3405
2 In addition to the smoke detector required by section 310 9 Group R Division
2 1 1 occupancies shall be provided with at least one manual pull station at a
location approved by the authority having jurisdiction Such pull station shall
actuate a distinctive fire alarm signal which shall be audible through out the
facility Section 310 102
3 Fully accessible rooms shall incorporate the requirements, together with their
sanitary facilities as per the following items and Table 11B-3 Accessible suites of
'City of Carlsbad O7-2573
10/16/07
rooms shall be dispersed among the various classes to provide a range of options
regarding room size, cost, amenities and number of beds All rooms shall comply
with section 1111B 4 5 for hearing impaired guests
a) 1 for each 25 rooms up to 100
b) In addition to rooms required above, the same number of rooms shall be
provided with the following features
i) Auxiliary visual alarms in compliance with section 1111B 4 5 1
n) Visual Notification Devices to alert the room occupants of incoming
telephone calls and a door knock or bell These devices shall not be
connected to auxiliary signal appliances
in) Permanently installed phones shall have volume controls and an
accessible electrical outlet within A8" to allow the use of a text phone
4 Accessible rooms with roll-in showers shall be provided as follows
a) 1 for between 51 and 100 rooms
5 Accessible sleeping rooms shall provide 36" clear width maneuvering space along
both sides of a bed, or between two beds
6 Public rooms and common use areas shall be made accessible as required by
other sections Section 1111B 2
7 Bathrooms in the accessible rooms shall comply with the following
a) Doors shall not swing into the required clear floor space for any fixture
b) There must be a minimum clear floor space of 30" by 60" The clear floor
spaces at fixtures and controls, accessible route and turning space may
overlap
c) Water closets must comply with sections 1115B and 1502 0 of the
California Plumbing Code This will require the following clearance
i) >60" diameter (or the T-shaped space from Figure 11B-12
d) Doors are not permitted to encroach into this space by more than 12
inches
e) Show that the water closet is located in a space, per Section 1115B7 2,
which provides
i) A minimum side clearance of either
a) >28" from a fixture
b) >32" from a wall on one side
n) >48" clear space in front of the water closet
f) Lavatories and mirrors shall comply with sections 1115B 9 and 1504 0 of
the California Plumbing Code
g) If tubs or showers are provided, at least one shall be accessible in
compliance with section 1115B 6 1 and 1506 0 of the California Plumbing
Code for tubs or 1115B 6 2 and 1505 0 for showers
' City of Carlsbad O7-2573
1O/16/O7
8 Bathrooms in all remaining units shall comply with the following
a) All bathroom fixtures shall be in a location that allows a person using a
wheelchair measuring 30 " by 48" to touch the wheelchair to any lavatory,
urinal, water closet, tub, sauna, shower stall and any other similar sanitary
installation if provided
b) All bathroom entrance doors shall have a clear opening width of 32" and
shall be either sliding doors or shall be hung to swing in the direction of
egress from the bathroom
When alterations, structural repairs or modifications or additions are made to an
existing building, that building, or portion of the building affected, is required to
comply with all of the requirements for new buildings, per Section 1134B 2 These
requirements apply as follows
a) A primary entrance to the building and the primary path of travel to the
altered area, must be shown to comply with all accessibility features
To speed up the review process, note on this list (or a copy) where each
correction item has been addressed, i e , plan sheet, note or detail number,
calculation page, etc
Please indicate here if any changes have been made to the plans that are not a
result of corrections from this list If there are other changes, please briefly
describe them and where they are located in the plans
Have changes been made to the plans not resulting from this correction list?
Please indicate
Yes Q No a
The jurisdiction has contracted with Esgil Corporation located at 9320
Chesapeake Drive, Suite 208, San Diego, Calilornia 92123, telephone number of
858/560-1468, to perform the plan review for your project If you have any
questions regarding these plan review items, please contact Doug Moody at
Esgil Corporation Thank you
City of Carlsbad 07-2573
10/16/O7
VALUATION AND PLAN CHECK FEE
JURISDICTION City of Carlsbad
PREPARED BY Doug Moody
BUILDING ADDRESS 2830 Cazadero Dr
BUILDING OCCUPANCY R-2.1 1
PLAN CHECK NO O7-2573
DATE 10/16/07
TYPE OF CONSTRUCTION VN
BUILDING
PORTION
R-3 to R-2 1 1
Air Conditioning
Fire Sprinklers
TOTAL VALUE
Jurisdiction Code
AREA
(Sq Ft)
cb
Rlrfn Pormif- PPP hw Hrrfm^nro ^T
Valuation
Multiplier
By Ordinance
Reg
Mod
VALUE ($)
Plan Check Fee by Ordinance $360 00
Type of Review
l~l Repetitive Fee
Repeats
D Complete Review
D Other
r-i Hourly
Structural Only
31 Hours
Esgil Plan Review Fee $288 00
* Based on hourly rate
Comments
Sheet 1 of 1
macvalue doc
City of Carlsbad
a^ ffBI^^WV^PMH^VWM^HH^^HBi^lP^VBHHMimHIIi^HH^HBBBB
/o/-!>~7o7DATE
BUILDINGAdDRESS _
PROJECT DESCRIPTION
ASSESSOR'S PARCEL NUMBER =P- /('
Public Wbrks: -1 Engineering
BUILDING PLANCHECK CHECKLIST
PLANCHECK NO CB fi 7
ENGINEERING DEPARTMENT
APPROVAL
The item you have submitted for review has been
approved The approval is based on plans,
information and/or specifications provided in your
submittal, therefore any changes to these items after
this date, including field modifications, must be
reviewed by this office to insure continued
conformance with applicable codes Please review
carefully all comments attached, as failure to comply
with instructions in this report can result in
suspension of permit to build
D A Right-of-Way permit is required prior to
construction of the following improvements
EST VALUE
DENIAL
Please see the attached report of deficiencies
marked with D Make necessary corrections to plans
or specifications for compliance with applicable
codes and standards Submit corrected plans and/or
specifications to this office for review Only the
applicable sheets have been sent
By
By
By
Date
Date
Date
By
FOR OFFICIAL USE ONLY
TO ISSUE BUILDING PERMIT
Date
X" /f
A 107
ATTACHMENTS
D Dedication Application/Checklist
r~i"-1 Improvement Application
U Improvement Checklist
D Neighborhood Improvement Agreement
[] Grading Submittal Checklist
D Right-of-Way Permit Application
D Right-of-Way Permit Submittal Checklist
and Information Sheet
LJ Storm Water Applicability Checklist
ENGINEERING DEPT CONTACT PERSON
Name KATHLEEN M FARMER
City of Carlsbad
Address 1635 Faraday Avenue, Carlsbad, CA 92008
Phone (760) 602-2741
NOTE- If there are retaining walls
associated with your project, please check
with the Building Department if these walls
need to be pulled by separate RETAINING
WALL PERMIT
1635 Faraday Avenue • Carlsbad, CA 92OO£?-7314 • (760) 602-2720 • FAX (760) 6O2-8562 ®
BUILDING PLANCHECK CHECKLIST
RD
./n D 3
D
n n
SITE PLAN
1 Provide a fully dimensioned site plan drawn to scale Show
A North Arrow
ETE-xisting & Proposed Structures
C-^Existmg Street Improvements
D Property Lines (show all dimensions)
E/1Easements / J
H
J3ight-of-Way Width & Adjacent Streets
Driveway widths
.
Existing or proposed sewer lateral
Existing or proposed water service
xistmg or proposed irrigation service
2 Show on site plan
A Drainage Patterns
1 Building pad surface drainage must maintain a minimum slope of one
percent towards an adjoining street or an approved drainage course
2 ADD THE FOLLOWING NOTE "Finish grade will provide a minimum positive
drainage of 2% to swale 5' away from building "
B Existing & Proposed Slopes and Topography
C Size, type, location, alignment of existing or proposed sewer and water service (s)
that serves the project Each unit requires a separate service, however, second
dwelling units and apartment complexes are an exception
D Sewer and water laterals should not be located within proposed driveways, per
standards
3 Include on title sheet
A Site address
B Assessor's Parcel Number
C Legal Description
For commercial/industrial buildings and tenant improvement projects, include
total building square footage with the square footage for each different use,
existing sewer permits showing square footage of different uses (manufacturing,
warehouse, office, etc ) previously approved
EXISTING PERMIT NUMBER DESCRIPTION
Show all existing use of SF and new proposed use of SF.
Example:
Tenant Improvement for 3500 SF of warehouse to 3500 SF of office.
BUILDING PLANCHECK CHECKLIST
1ST 2NU 3KU DISCRETIONARY APPROVAL COMPLIANCE
D D D 4a Project does not comply with the following Engineering Conditions of approval for
Project No
4b All conditions are in compliance Date
DEDICATION REQUIREMENTS
EH D CD 5 Dedication for all street Rights-of-Way adjacent to the building site and any storm
dram or utility easements on the building site is required for all new buildings and
for remodels with a value at or exceeding $ 17.000 . pursuant to Carlsbad
Municipal Code Section 18 40 030
Dedication required as follows
Dedication required Please have a registered Civil Engineer or Land Surveyor
prepare the appropriate legal description together with an 8 Yz" x 11" plat map and
submit with a title report All easement documents must be approved and signed
by owner(s) prior to issuance of Building Permit Attached please find an
application form and submittal checklist for the dedication process Submit the
completed application form with the required checklist items and fees to the
Engineering Department in person Applications will not be accept by mail or fax
Dedication completed by Date
IMPROVEMENT REQUIREMENTS
CI 6a All needed public improvements upon and adjacent to the building site must be
constructed at time of building construction whenever the value of the
construction exceeds $ 82.000 . pursuant to Carlsbad Municipal Code Section
1840040
Public improvements required as follows
Attached please find an application form and submittal checklist for the public
improvement requirements A registered Civil Engineer must prepare the
appropriate improvement plans and submit them together with the requirements
on the attached checklist to the Engineering Department through a separate plan
check process The completed application form and the requirements on the
BUILDING PLANCHECK CHECKLIST
3RD
CD checklist must be submitted in person Applications by mail or fax are not
accepted Improvement plans must be approved, appropriate securities posted
and fees paid prior to issuance of building permit
Improvement Plans signed by __ Date _
D 6b Construction of the public improvements may be deferred pursuant to Carlsbad
Municipal Code Section 1840 Please submit a recent property title report or
current grant deed on the property and processing fee of $ 430 00 so we may
prepare the necessary Neighborhood Improvement Agreement This agreement
must be signed, notarized and approved by the City prior to issuance of a
Building permit
Future public improvements required as follows
EH CD 6c Enclosed please find your Neighborhood Improvement Agreement Please return
agreement signed and notarized to the Engineering Department
Neighborhood Improvement Agreement completed by
Date
D CH D 6d No Public Improvements required SPECIAL NOTE Damaged or defective
improvements found adiacent to building site must be repaired to the satisfaction
of the City Inspector prior to occupancy
GRADING PERMIT REQUIREMENTS
The conditions that invoke the need for a grading permit are found in Section
11 06 030 of the Municipal Code
n 7a Inadequate information available on Site Plan to make a determination on grading
requirements Include accurate grading quantities in cubic yards (cut, fill import,
export and remedial) This information must be included on the plans.
CD 7b Grading Permit required A separate grading plan prepared by a registered Civil
Engineer must be submitted together with the completed application form
attached NOTE The Grading Permit must be issued and rough grading
approval obtained prior to issuance of a Building Permit
Grading Inspector sign off by Date
7c Graded Pad Certification required (Note Pad certification may be required even
if a grading permit is not required )
ST1
D
D
•>ND
n D
•,RD
D D
BUILDING PLANCHECK CHECKLIST
7d No Grading Permit required
7e If grading is not required, write "No Grading" on plot plan
MISCELLANEOUS PERMITS
8 A RIGHT-OF-WAY PERMIT is required to do work in City Right-of-Way and/or
private work adjacent to the public Right-of-Way Types of work include, but are
not limited to street improvements, tree trimming, driveway construction, tying
into public storm drain, sewer and water utilities
Right-of-Way permit required for
G D 9 INDUSTRIAL WASTE PERMIT If your facility is located in the City of Carlsbad
sewer service area, you need to contact the Carlsbad Municipal Water District,
located at 5950 El Camino Real, Carlsbad, CA 92008 District personnel can
provide forms and assistance, and will check to see if your business enterprise is
on the EWA Exempt List You may telephone (760) 438-2722, extension 7153,
for assistance
Industrial Waste permit accepted by
Date
NPDES PERMIT
D D D 10a Storm Water Requirements Applicability Checklist Completed
D O D 10b Priority Determination and compliance
D Priority Project
D Subject to Standard Permanent Stoim Water BMP's
D Exempt
STORM WATER APPLICABILITY CHECKLIST
D D D 10c Q Requires PSWP (Project Storm Water Permit) #_
Q Not required
Required fees are attached
No fees required
WATER METER REVIEW
.. ST 2ND 3RD
D D D 12a Domestic (potable) Use
Ensure that the meter proposed by the owner/developer is not oversized
Oversized meters are inaccurate during low-flow conditions If it is oversized,
for the life of the meter, the City will not accurately bill the owner for the water
used
• All single family dwelling units received "standard" 1" service with 5/8" service
• owner/developer proposes a size other than the "standard", then
owner/developer must provide potable water demand calculations, which
include total fixture counts and maximum water demand in gallons per minute
(gpm) A typical fixture count and water demand worksheet is attached Once
the gpm is provided, check against the "meter sizing schedule" to verify the
anticipated meter size for the unit
• Maximum service and meter size is a 2" service with a 2" meter
Q |~] CD 12b Irrigation Use (where recycled water is not available)
All irrigation meters must be sized via irrigation calculations (in gpm) prior to
approval The developer must provide these calculations Please follow
these guidelines
If the project is a newer development (newer than 1998), check the recent
improvement plans and observe if the new irrigation service is reflected on the
improvement sheets If so, at the water meter station, the demand in gpm
may be listed there Irrigation services are listed with a circled "I", and potable
water is typically a circled "W"
1 If the improvement plans do not list the irrigation meter and the
service/meter will be installed via another instrument such as the building
plans or grading plans (w/ a right of way permit of course), then the
applicant must provide irrigation calculations for estimated worst-case
irrigation demand (largest zone with the farthest reach) Typically, Larry
Black has already reviewed this if landscape plans have been prepared,
but the applicant must provide the calculations to you for your use Once
you have received a good example of irrigation calculations, keep a set for
your reference In general the calculations will include
• Hydraulic grade line
• Elevation at point of connection (POC)
• Pressure at POC in pounds per square inch (PSI)
• Worse case zone (laigest, farthest away from valve
• Total Sprinkler heads listed (with gpm use per head)
• Include a 10% residual pressure at point of connection
2 In general, all major sloped areas of a subdivision/project are to be
irrigated via separate irrigation meters (unless the project is only SFD with
no HOA) As long as the project is located within the City recycled water
BUILDING PLANCHECK CHECKLIST
A ST oND oRD\ £. O
service boundary, the City intends on switching these irrigation
services/meters to a new recycled water line in the future
CD CD CD 12c Irrigation Use (where recycled water is available)
1 Recycled water meters are sized the same as the irrigation meter above
2 If a project fronts a street with recycled water, then they should be
connecting to this line to irrigate slopes within the development For
subdivisions, this should have been identified, and implemented on the
improvement plans Installing recycled water meters is a benefit for the
applicant since they are exempt from paying the San Diego County Water
Capacity fees However, if they front a street which the recycled water is
there, but is not live (sometimes they are charged with potable water until
recycled water is available), then the applicant must pay the San Diego
Water Capacity Charge If within three years, the recycled water line is
charged with recycled water by CMWD, then the applicant can apply for a
refund to the San Diego County Water Authority (SDCWA) for a refund
However, let the applicant know that we cannot guarantee the refund, and
they must deal with the SDCWA for this
D CD CD 13 Additional Comments:
D
D
ENGINEERING DEPARTMENT
FEE CALCULATION WORKSHEET
Estimate based on unconfirmed information from applicant
Calculation based on building plancheck plan submittal
Address Bldg Permit No
Prepared by Date Checked by Date
EDU CALCULATIONS List types and square footages for all uses
Types of Use Sq Ft /Units
Types of Use Sq Ft /Units
APT CALCULATIONS List types and square footages for all uses
Types of Use Sq Ft /Units
Types of Use Sq Ft /Units
EDU's
EDU's
ADT's
ADT's
FEES REQUIRED
WITHIN CFD D YES (no bridge & thoroughfare fee in District #1, reduced Traffic Impact Fee) D NO
D 1 PARK-IN-LIEU FEE
FEE/UNIT
PARK AREA & #
X NO UNITS = $
D 2 TRAFFIC IMPACT FEE
ADT's/UNITS
D 3 BRIDGE AND THOROl
ADT's/UNITS
D 4 FACILITIES MANAGE
UNIT/SO FT
D 5 SEWER FEE
EDU's
FEE/ADT = $
JGHFARE FEE
VIENT FEE
(DIST
X
ZONE
X
#1 DIST #2
FEE/ADT
FEE/SO FT /UNIT
DIST #3 )
-$
-$
BENEFIT AREA
EDU's
FEE/EDU
FEE/EDU
D 6 SEWER LATERAL ($2,500)
D 7 DRAINAGE FEES PLDA
ACRES
D 8 POTABLE WATER FEES
UNITS CODE CONNECTION FEE
= $_
= $_
= $
HIGH /LOW
FEE/AC = $
METER FEE SDCWA FEE IRRIGATION
Word\Docs\Mlsforms\Fee Calculation Worksheet
1 Of 2
PLANNING/ENGINEERING APPROVALS
PERMIT NUMBER CfiOl DATE 10
ADDRESS
RESIDENTIAL TENANT IMPROVEMENT
RESIDENTIAL ADDITION MINOR
« $10,000.00)
PLAZA CAMINO REAL
CARLSBAD COMPANY STORES
VILLAGE FAIRE
COMPLETE OFFICE BUILDING
PLANNER
ENGINEER DATE
Oocs/Mbforms/Piannina Engineenng Approvals
Carlsbad Fire Department
Plan Review Requirements Category RESDNTL , RAD
Date of Report 12-26-2007 Reviewed by
D
Name
Address
ZEZELJ FAMILY TRUST 0 1 -30-04
2807 LUCIERNAGA ST
CARLSBAD CA92009
Permit # CB072573
Job Name ZEZELJ RES- CONVERT SFD TO
Job Address 2830 CAZADERO DR CBAD
» **> ^&D& DEPT COPY
Conditions:
Cond CON0002421
[MET]
1 Egress plan shall be subletted showing path of travel to public way Include material and
slope
2 Egress doors directly to exterior shall swing in the direction of travel
3 Sheet 1 - Scope of work shall reflect actual work to be done on current permit
4 Sleeping rooms shall have smoke detectors within as well as in hallways leading to sleeping
rooms
Entry 11/02/2007 By cwong Action CO Entry 12/26/2007 By cwong Action AP
Cond CON0002506
rS.taTioli^d-Bell-sh^
r-DepaftmenP All devices shall be Califroma State Fire Marshal approved The wiring shall be in
accordance with the National electric Code The fire alarm, when initiated, shall provide a
distinctive tone that shall be audible throughout the facility An electrical permit may be
required for the installation of this device The power supply shall be wired on a circuit that
cannot be interrupted by a disconnecting switch (e g , a wall switch) It is preferrable that the
circuit that the manual pull is wired to also serve other c ommonly used appliances in the
residence The manual pulls need not be interconnected to any other fire alarm device,
eleftromcally supervised, or provided with emergency power CBC 310 102, CFC 1006 2923
Entry 12/26/2007 By cwong Action AP
Cond CON0002508
THIS PROJECT HAS BEEN REVIEWED AND APPROVED FOR THE PURPOSES OF ISSUEANCE OF A
BUILDING PERMIT
THIS APPROVAL IS SUBJECT TO FIELD INSPECTIONS, ANY REQUIRED TESTS, FIRE DEPARTMENT
NOTATIONS,
CONDITIONS IN CORRESPONDENCE AND COMPLIANCE WITH ALL APPLICABLE CODES AND
REGULATIONS
THIS APPROVAL SHALL NOT BE HELD TO PERMIT OR APPROVE ANY VIOLATION OF THE LAW
Entry 12/26/2007 By cwong Action AP
Carlsbad Fire Department
Plan Review Requirements Category RESDNTL , RAD
Date of Report 11-02-2007 Reviewed by ( '
Name ZEZELJ FAMILY TRUST 01-30-04
Address
2807 LUCIERNAGA ST
CARLSBAD CA
92009
Permit # CB072573
Job Name ZEZELJ RES- CONVERT SFD TO
Job Address 2830 CAZADERO DR CBAD
BLDG. DEPT COPY
INCOMPLETE The item you have submitted for review is incomplete At this time, this office cannot
adequately conduct a review to determine compliance with the applicable codes and/or standards Please review
carefully all comments attached Please resubmit the necessary plans and/or specifications, with changes "clouded",
to this office for review and approval :
Conditions:
Cond CON0002421
[NOT MET]
1 Egress plan shall be subletted showing path of travel to public way Include material and
slope
2 Egress doors directly to exterior shall swing in the direction of travel
3 Sheet 1 - Scope of work shall reflect actual work to be done on currem permit
4 Sleeping rooms shall have smoke detectors within as well as in hallways leading to sleeping
rooms
Entry 11/02/2007 By cwong Action CO
Carlsbad Fire Department
Plan Review Requirements Category RESDNTL , RAD
Date of Report 11-01 -2007 Reviewed by
Name ZEZELJ FAMILY TRUST 01-30-04 "
Address
2807 LUCIERNAGA ST
CARLSBAD CA
92009 BLDG. DEPT COPY
Permit # CB072573
Job Name ZEZELJ RES- CONVERT SFD TO
Job Address 2830 CAZADERO DR CBAD
INCOMPLETE The item you have submitted for review is incomplete At this time, this office cannot
adequately conduct a review to determine compliance with the applicable codes and/or standards Please review
carefully all comments attached Please resubmit the necessary plans ami/or specifications, with changes "clouded",
to this office for review and approval
Conditions:
Cond CON0002412
[NOT MET]
1 Egress plan shall be submitted showing path of travel to public way Include material
2 All path of egress doors shall swing in the direction of travel Exterior egress path material
and slope shall be specified
3 Sheet 1 - Scope of work shall reflect actual work to be done on currenl permit
Entry 11/01/2007 By cwong Action CO
LU
01
COCOLU
Ct
O
<D
cc
Q- <
§£DBu to m
Q I- 2 .< o: < r<y^<
3>OQ
LU
m LU < LJo N o a
J
4
i
Ji-pK.a. QL!
t£.K oe
' 2 «ar iS 5 tf
-Jiialf £<n a. uj £ x x o 2
OQ!
sP
^
- ILI
0
.
ro O^-»<r
o Q
j
r
eta.u.<
§
E$
<o p a co CL
J
QI2
S.
•-*,
7
-
£
«I
•^
^ V>0 (.^o