Loading...
HomeMy WebLinkAbout2840 CACATUA ST; ; 77-7943; PermitMODEL N?. BUILDING PERMIT APPLICATION City of CARLSBAD, CALIFORNIA 92008 Phone 729-1181 Permit No. 77 7943 I’ $9 -- SESsblM+** 5 * - * Applicant to complete numbered spaces only. JOB ADDR E55 PARCEL NUMBER 6 U SROi L DI N 6 NO. BORMS 4 8 Class of work: dNEW 0 ADDITION 0 ALTERATION 0 REPAIR 0 MOVE 0 REMOVE 9 Describe work: 10 Change of use from Change of use to 11 Valuation of work: $ 7.st 70 st, r .- SPECIAL CONDITIONS: SEPARATE PERMITS ARE REQUIRED FOR ELECTRICALJPLUMB- ING, HEATING, VENTILATING OR AIR CONDITIONING. TlON AUTHORIZED IS NOT COMMENCED WITHIN 120 DAYS,OR IF CONSTRUCTION OR WORK IS SUSPENDED OR ABANDONED FOR A MENCED. THIS PERMIT BECOMES NULL AND VOID IF WORK OR CONST-RUC- PERIOD OF 120 DAYS AT ANY TIME AFTER WORK IS COM- SIGNATURE OF CONTRACTOR on AUTHORIZED AGENT (DATE) SIGNATURE OF OWNER (IF OWNER BUILDER1 (DATE) * No. of Size of Bldg. (Total) Sq. F&% I Stories Occ. Load Dwelling Units PLANNING DEPT. SOIL REPORT ENGINEERING DEPT. I I I WATER DEPT. I I I r, WHEN PROPERLY VALIDATED (IN THIS SPACE) THIS IS YOUR PERMIT PLAN CHECK VALIDATION CK. M.O. CASH PERMIT VALIDATION CK. M.O. CASH TOTAL FEES r 7 3-79 43 tNSPECTION RECORD -, I DATE I REMARKS 1 INSPECTOR FOUNDATIONS: SET BACK I I I TRENCH I REINFORCING FOUNDATION WALL & ..lP*-r..*C. -C.fi*r...II TIME: INSPECTOR PERMIT NO. OWNER BUILDING 0 FOUNDATION 0 REINFORCING STEEL 0 MASONRY 0 GROUT - GUNlTE 0 FLOOR AND CEILING FRAME c] SHEATHING 0 FRAME 0 EXTERIOR LATH 0 INSULATION 0 INTERIORLATH OR DRYWALL ?d FINAL 0 UNDERGROUND PLUMBING 0 UNDERGROUND WATER - READ 0 ROUGH PLUMBING In 0 0 0 0 0 0 YF TOP OUT PLUMBING SEWER AND PL/CO TUB OR SHOWER PAN GAS TEST E L ECT R IC A L 0 TEMPORARY SERVICE 0 ELECTRIC UNDERGROUND 0 ROUGH ELECTRIC 0 POOL BONDING 0 ELECTRIC SERVICE 0 CEILING HEAT c3. G.F.I. 0 SMOKE DETECTOR 0 FINAL I MISCELLANEOUS WATER HEATER FINAL OR INSPECTION: 0 0 A.M. 0 P.M. 0 PLENUM AND DUCTS 0 COMBUSTION AIR 0 PATIO 0 SIGN 0 GRADING 0 DRIVEWAY 0 CONDITIONED AIR SYST 0 REFER PIPING 0 FINAL I WEDNESDAY THURSDAY 3 'EMS 0 FRIDAY SPECIAL INSTRUCTIONS Y PERSON TAKING REPORT REQUESTED BY PLUMBING PERMIT APPLICATION APPLICATION AND KNOW THE SAME TO BE TRUE AN0 CORRECT. ALL PROVISIONS OF LAWS AND ORDINANCES GOVERNING THIS TYPE OF WORK WILL BE COMPLIED WITH WHETHER SPECIFIED HEREIN OR NOT THE GRANTING OF A PERMIT DOES NOT PRESUME TO GIVk AUTHORITY TO VIOLATE OR CANCEL THE PROVISIONS OF ANY OTHER STATE OR LOCAL LAW REGULATING CONSTRUCTION OR THE PERFORMANCE OF CONSTRUCTION. City of CARLSBAD, CALIFORNIA 92008 Phone 729-1181 bplicant to complete numbered spaces only. Perm it No. 7 7-4iiYJp I JOS ADOILIS WATER PIPING L TREATING EQUIP. WASTE INTERCEPTOR VACUUM BREAKERS LAWN SPRINKLER SYSTEM . COMP ENS A T ION IN S.J 4R Rpe WAIL ADDICSS I 18 Chef work: HNEW AOOlTlON 0 ALTERATION 0 REPAIR I 8 Oacribrwork: PERMIT FEES I PERIOD OF 120 DAYS AT ANY TIME AFTER WORK IS COM- I 1 SLOPSINK Ill I 4. I ,434 - GAS SYSTEMS: NO. OUTLETS , CESSPOOL 1 XPTiC TANK & PIT ROOF DRAINS PLAN CHECK VALIDATION CK. M.O. CASH PERMIT VALIDATION CK. M.O. . CASH ., 3 ......... .. i ............ ..+ ..... INSPECTOR ELECTRICAL PERMIT APPLICATION LOT NO. BLK. I E::k. TRACT (OSEE ATTACHED SHEET) ENGINEER MAIL ADDRESS PHONE LICENSE NO. b BRANCH TES?C COMPENSATION INS CARRIER * clisllan eo, ,4 7 f- USE OF BUILDING ’rjkyl;leFsmily~ I Class of work: a NEW 0 ADDITION ALTERATION 0 REPAIR I Dewibework: nrwwd wf~ins c PERMIT-= PECIAL CONDITIONS: I P WPLICATION ACCEPTEO BY I PUNS CHECKED BY I APPROVED/O@ISUANCE BV NOTICE THIS PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUC- TION AUTHORIZED IS NOT COMMENCED WITHIN 120 DAYS,OR IF CONSTRUCTION OR WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 120 DAYS AT ANY TIME AFTER WORK IS COM MENCED. i ‘4, /..*/ “-7- -. -4 SIGNATURE OF CONTRACTOR OR AUTHORIZED AGENT (DATE) SIGNATURE OF OWNER (IF OWNER BUILDER) (DATE) SWIMMING POOL WIRING, NO INCREASE IN SERVICE NEW CONSTRUCTION, FOR EACH AMPERES OF MAIN SERVICE, SWITCH, FUSE OR BREAKER NEW SERVICE ON EXISTING BLDG. FOR EA. AMPERE OF INCREASE IN MAIN SERVICE. SWITCH. FUSE OR BREAKER REMODEL, ALTERATION, NO CHANGE IN SERVICE, FOR EA. AMPERE OF IN CR EASE TEMP. SERVICE UP TO AND INCLUD- ING 200 AMP. TEMP. SERVICE OVER 200 AMP. PER 100 ISSUANCE FEE TOTAL FEES 100 - Each - 25 I WHEN PROPERLY VALIDATED (IN THIS SPACE) THIS IS YOUR PERMIT PLAN CHECK VALIDATION CK. M.O. CASU PERMIT VALIDATION CK. M.O. CASU INSPECTOR MECHANICAL PERMIT APPLlC4&ltOM--- * :. ~ ..,rd,,g Permit No. 75% City of CARLSBAD, CALIFORNIA 92008 Phone 7 29-1 181 Applicant to complete numbered spaces only, r Jon ADDR Ess /41 I LOT NO. DLU LCCAL 1 DCSCR. TRACT (OSEE ATTACMED SHEET1 - CONTRACTOR_ I MAIL ADD ESS - PHONE CITY LIC. NO. STATE LIC. NO. * SPECIAL CONDITIONS: -, LICENSE NO. Typeof Fuel: Oil 0 Nat. Gas Cr"LPG. 0 PERMIT FEES No. Type of Equipment Fee Air Cod. Units-H.P. Ea. $1 Refrberation Units-H.P. Ea. 4 5 LICENSE NO. CN C IN EER MAIL AODRESS PYONE WQYT MAIL ADDRESS IRhNCN 18 Class of work: WW 0 ADDITION 0 ALTERATION 0 REPAIR ~ 9 Describe work: I I I Boilers-H.P. Ea. II Gas Fired A.C. Units-Tonnage Ea. Gravitv Svstems-B.T.U. M Ea. I Forced Air Systems-B.T.U. M Ea. APPLICATION ACCEPTED BY PLANS CHECKED EV APPROVED FOR ISSUANCE 8V c .. Floor F urnaces-B.T.U. M I I Wall Heaters43.T.U. M ;? M ,,wr. NOTICE Unit He6ten-B.T.U. THIS PERMIT BECOMES NULL AND VOID IF WORK OR CONSTRUC- TlON AUTHORIZED IS NOT COMMENCED WITHIN 120DAYS.OR IF CONSTRUCTION OR WORK IS SUSPENDED OR ABANDONED FOR A PERIOD OF 120 DAYS AT ANY TIME AFTER WORK IS COM- Ventilation Fan Evaporative Coolers Clothes Dryers ' MENCED. I I RanaeHood II I Air Handling Unit- C.F.M. I I I Incinerator I I I I I I I I I J I I I I I TOTAL FEES WHEN PROPERLY VALIDATED (IN THIS SPACE) THIS IS YOUR PERMIT PLAN CHECK VALIDATION CK. M.O. cnsH PERMIT VALIDATION CK. M.O. CASH INSPECTOR CORRECTION LIST CITY OF CARLSBAD BUILDING DEPARTMENT SINGLE FAMILY AND MULTIPLE FAMILY RESIDENTIAL PLAN / f ..- (714) 729-1181 *WARNING: PLAN CHECK FEES: Where no action is taken by the applicant in 120 days, and no building permit is .y: Job Address: 2 e40 (!?Amha Owner Contractor: \ Engineer Occupancy . Type of Construction Valuation Basic allowable bldg. area Jst Floor 2nd Floor Allowable Increase Due to REQUIRED PL \ 3. Floor Plan 8. Roof Plan 4. General Framing 9. Index Sheet 5. Foundation Details TO THE APPLICANT A. Correct Plans where corrections has been circled. Flag Corrections. B. Incomplete, Indefinite or Faded Drawings or Calcu- lations not acceptable. C. Required Engineer’s or Surveyor’s Calculations or Plans shall be signed in ink. D. Reverse Plans may not be used. Provide correct Plot Plan, Foundation Plan, Floor Plan and Elevations. E. The approval of plans and specifications does not permit the violation of any section of the Building Code‘or other City, County or State Law. 4th Floor 24. Indicate clearance from grade to bottom of floor joists ow pier size, spacing and depth, into undisturbed and girders. e girder size, spacing and direction. all conditions of soils report on plans. positive drainage away from footings on site n. 5” fall in 6 feet. 29. Specify minimum 18” x 24” access opening. 30. Where expansive soils exist, planters adjacent to found- ations are not recommended. 31. Specify underfloor ventilation equal to 2 square feet for each 25 lineal feet of foundation plus one opening within 3’ of each corner. 32. Step footings when slope exceeds 1 : 10. FRAMING 33. Provide typical framing details. 34. Specify all lumber grades. 35. Specify fire blocking at floor, ceiling cove and mid- height of walls over 10’ in height. 36. Show diagonal bracing at each corner and every 25 feet of wall. 38. Show size, direction and spacing of floor joists in 39. Double floor joists or GENERAL 1. Submit fully dimensioned Plot Plan, drawn to scale, 37. Clarify bracing of wall. are overspanned. including all easements on property. 2. Show all existing and proposed buildings on Plot Plan. 3. Show correct legal description on Plan. 4. Show all Off Site Improvements, Driveway Approach, beam under parallel partitions. Light Standards, Fire Hydrants, Water Meters, Sub size for openings over 4’. Show double Structures, Trees, etc. ceiling joists and rafters are spacing and direction. rect Lot Dimensions. w existing and finish contour lines.& icate all grading to be done. icate Elevations of Garage Floor, and Street and eY - ‘ . )’Wk+hA -td 4’0.C. 44. Show purlins on edge and indicate size. Same size as rafters minimum. 10Undicate-Centerline and Edge Profile of Driveway. 11. Slope of driveway not to exceed 15%. isposal of surface water& l3aSan Diego County Health Dept. approval required. 13bShow all requirements for handicapped. U.B.C. 13cL.C.W.D. sew < receipt required. 13dCoastal approval letter required. 14. Carry water from Section 1711. under sidewalk through curb into street with cast iron pipe. 15. Provide engineering calculations for ovide engineer’s moisture report. ading permit required. 18. Fire Dept. approval required. 19. Specify concrete mix @ 2000 P.S.I. minimum. 20. Dimension footing sizes and clearance from grade. 21. Show depth of footings below natural or undisturbed 22. Indicate pressure treated foundation still, or equal. 23. Show foundation bolt size, spacing and penetration grade. into concrete. %” x 17” for masonry. 45. Brace roof framing to partitions. 46. Indicate solid sheathing and 2 x 6 or 3 x 4 studs on first floor of three story construction. 3 47. Show section through 48. Show planter box details and water proofing, Sec. 51. Provide typical chimney details. 52. Specify 2” minimum clearance between chimney and 53. Specify post protection when bearing on concrete. 54. Provide parapet details. 56. Specify inspection class 58. Provide drip screed 2” below mud sill. 59. Indicate how required structural and fire resistive integrity will be maintained. Where penetration will - be made for electrical, mechanical, plumbing and communications conduits, pipes and similar systems. Section 301 D. 2517 C7. framing. required for 60. Clarify dimensions at 61. Show window type, sizes and locations. 62. Light and/or ventilation inadequate in (1/10 floor area - 12 square feet min. except bath- room), 1 **NOTE IN MARGIN WHERE CORRECTIONS HAVE BEEN MADE 53. Provide, vertical clearance and * horizontal clearance from range top to combustibles. 54. Indicate attic scuttle (22” x 30” min.) 55. Provide draft separation for attic area in excess of 2500 sq. ft. 66. Separate area between dropped ceiling and floor above to 1000 sq. ft. max. 67. Specify stall shower min. width 30” minimum floor area 900 sq. inches. 68. Specify wall finish in shower area not to be adversely affected by moisture to 6‘ above the floor, and provide shatterproof doors. 69. Water closet area minimum width to be 30”. 70. Show material to be used under tile. 71. Openings closer than 72. Show ceiling height. 73. Show lateral cross bracing at garage plate line. 74. Show bedroom window as exit, section 1304. to property line shall be of hour construction. ELEVATIONS 75. Indicate attic ventilation per section 3205 (c). 76. Show all eave overhangs and construction details. 77. Dimension chimney height above roof. (2’0” above 78. Indicate finish and natural grade to property line. 79. Show exterior wall finishes. 80. Indicate 15# felt or equal on exterior walls. roof withing 10’0’’). ROOF 81. Note roof pitch. 82. Indicate roofing material length & weather exposure 83. Show type, size and spacing of roof sheathing. 84. Fire retardant roof required due to location in on wood shingles. fire zone. GARAGES 86. Garages not permitted to open into sleeping room. 87. Provide separation on all walls 88. Specify door/window opening and ceilings adjacent to living quarters. from garageharport into STAIRWAYS AND EXITS 90. Provide handrails as required in Section 3305 (i). 92. Provide 93. Indicate maximum rise and minimum 95. Provide balcony railing at 42” minimum height. 36” 96. Provide intermediate rails @ 9” O.C. or equivalent 97. Indicate 6’ 6” minimum headroom clearance above 98. Show stairway construction details. hour walls for stairwell. run on stair. O.K. for single family units. for open type balcony & stair rails. stairway. 100. Occupant load requires exits 101. Provide lights over stairways and public corridors. 102. Show change in floor level at doors 1” rnax. Sec. 330311. 102aShow handrail extending 6” beyond the top & bottom risers & terminating in a post or safety terminal Sec. 3305 (i). from PLUMBING 103. Indicate location of water heater. 104. Show temperature and pressure relief valves on water heaters with discharge lines to outside. Sec. 1007. 105. Water heater not to be located in bathroom or under stairway or landing. 106. Provide square inches of ventilation at top and bottom of water heater. 107. Show water heater on 18 inch platform. 110. Indicate material to be used and location of sewer (If V.C.P. use flexible compression joints only.) 111. Show two way clean out in yard box with 5’ of build- line. ing. ELECTRICAL 112. Provide minimum 100 Amp. service. Condos require 113. Show meter and panel location. 113aShow fire warnings systems centered over stairs. 100 Amp. panel for each unit. Section 1310. MECHANICAL 114. Indicate furnace size, locations & registers and return air. (Size) 115. Indicate heating equipment in accordance with chapter 7 of Uniform Housing Code. 116. Specify heating, air conditioning and ventilating equipment. Installations to comply with the uniform mechanical code. A. Access F. Ducts B. Location G. Ladder & Light C. Combustion Air H. Engineer’s D. Venting Calcs for E. Return Air Roof Loads 117. Indicate location & type of fire dampers. ELECTRIC 1975 N.E.C. 1. Ground-fault protection required for outdoor and 2. At least one receptical shall be installed outdoors bathroom receptacles 210-8. garages. 210-25b electric as shown on floor plan. Underground service is required. Show on plans. MISCELLANEOUS ITEMS 1,Bored holes and notching, show details as per Section . Ft. areas of the follow 74703 4” insulation in walls (R-11) exterior doors weatherstriped the following note on plans: These plans comply with the requirements of the California noise insulation standards. SIGNED DATE TITLE F. Show details of party wall and floor system and S.T.C. or I.C.C. rating of each. 4. Have designer sign and date plans. CHECKED (DATE) RECHECKED (DATE) THE FOREGOING CORRECTIONS HAVE BEEN MADE AND ARE UNDERSTOOD BY THE UNDERSIGNED: OWNER - OR HIS AUTHORIZED AGENT \- B B - > UILDTNG UILDING INTERDEPARTMENTAL INFORMATION SHEET DEPARTMENT ADDRESS: PLANNING DEPARTMENT ZONE LOT SIZE /P 1717 LOT WIDTH ff UNITS ALLOWED / UNITS PROVIDED PARKING SPACES REQUIRED % COVERAGE ALLOWED BUILDING HEIGHT ALLOWED PROVIDED I PROVIDED 3 ---c FRONT SETBACK: ALLOWED PROVIDED INTRUSIONS 7 '$fy$()( LANDSCAPE & IRRIGATION PLAN SIDE SETBACK: REAR SVTBACK: 1 COMMENTS: ENFIRONMENTAL PROTECTION REQ: -r n A OK TO FINAL f&!L DATE &/-?e FIRE DEPARTMENT . SPRIIiKLING SYSTEM FIRE PROTECTION EQUIP. FIRE ALARMS EXITS & * FIRE HYDRANTS LOCATION ADDITIONAL COMMENTS OK TO ISSUE: DATE OK TO FINAL DATE r ALPHA LABORATORIES, .INC. SOIL & FOUNDATION ENGINEE-RING ' PROJELT NC): V~O~J- - 16 Nov. 1977 DA? E : TO : Euqene Smith 3519 Catal ina Carlsbad, Cal if. 92008 Gent 1 emen : Ttlis is to report the results of observations and soil tests ;.crfor;r;r,d cn 15 Nov. 1977 at 2840 Cacatua, La Costadal if. Lot 495_Meado3S-.#3__ .? - for the Durpose of determining the rroisture wntent in the exst.';-; 12 :,oi .> includd on the su:ject sitc. Field explorations were made tc retrieve soil sarrples in t.he centpr o? !-be building pad. Test. pits were dug tct a d+th of at least 3 fett belw finisii grade and molsture samnles were Gbtained at intermcdiats ieveis. \.;e fnund he! field caisture to be 24 % A wxirnum dry density deterninzticn was perfcrrxd in accordance ::itti ASTb1 P!35? to ascertain the optimun: moisture content of the subject coi I. The .rca:tirnuz density was found to be - 114.5 Lbs. Cu. Ft. at 16.2 2 gigi:,Lure. In conclusion we find the field moisture exceeds the optimum by -7t least 7% - percent which meets the minixurn requirements for presaturation of expansive soils. If you have any questions, please do not hesitate to contact this office. The opportunity to be of service is sincerely appreciated. Respectfully submitted, ALPHA LABORATORIES, INC. t cc: (I) Submitted- 7895 Convoy Court - San Diego - California 92111 - 7141292-0660 LEUCADIA COUNTY WATER DISTRICT POST OFFICE BOX 2397 LEUCADIA. CALIFORNIA 92024 753-01SS June 20, 1977 Mr. Michael Enken 540 Saxony Road Encinitas, CA 92024 .. Dear Applicant: adopted Resolution No. 542 which provided for the expiration of sewer permits after 30 days if a building permit had not been obtained. On March 24, 1977 the Board of Directors of Leucadia County Water District Therefore, your sewer permit No. 6764 dated 5/18/77 for property located at ' 2840 Cacatua Street has expired and the permit is hereby cancelled. to be held on-: may reapply far a sewer service permit at the District office, At that time it will be necessary for you to pay the applicable connection fee. The connection fee will be refunded to you at the Board ineeting July 12, 1977' I . If it is your intention to pursue a building permit for this property you I If you have any questions regarding this matter please contact me. Yours very truly, 1 EUCADIA COUNTY WATER DI STRI CT- . CC: City of Carlsbad .. . t. v Joan R, Geisefhart .: RECEIVED JUN 2 2 1977 CITY OF CARLSBAD J Building Dc>ar:ment LEUCADIA COUNTY WATER DISTRICT APPLICATION FOR SEWER SERVICE Owner's Name: Eugene M. Smith Phone No. 729-4332 Mailing Address: 3519 Catalina Carlsbad, CA 92008 Trnct Description: La Costa Meadows Unit #3 Lot 495 Type of Building: Single Family No. Units Connection Charge $600.00 Lateral Size: 4" 6" 8" Saddle: - Extra footage: @$ Easement Connection Extra depth: @$ t Amount Rec'd $ 600 .oo J HOW Paid cash Date Paid 6/33/77 Lateral Charge Total $600.00 The application must be signed by the owner (or his authorized representative) of the property to be served. application is submitted. The total charges must be paid to the District at the time the If a service lateral is required, it will be installed by the Leucadia County Water District. The service lateral is that part of the sewer system that extends from the main collection line in the street (or easement) to the point in the street (at or near the applicant's property line) where the service lateral is connected to the applicant's building sewer. The applicanb. is responsible for the construction, at the applicant,s expense, of the sewer pipeline (building sewer) from the applicant's plumbing to the point in the street (or easement) where a connection is made to the service lateral. The connection of the applicant's building sewer to the service lateral shall be made by the applicant at his expense. District's specifications, rules and regulations; and IT MUST BE INSPECTED AND APPROVED BY THE DISTRICT BEFORE THE SEWER SYSTEM MAY BE USED BY THE APPLICANT. THE APPLICANT, OR HIS AUTHORIZED REPRESENTATIVE, MUST NOTIFY THE DISTRICT AT THE TIME INSPECTION IS DESIRED. ANY CONNECTION MADE TO THE SERVICE LATERAL OR COLLECTION LINE WITHOUT PRIOR APPROVAL AND INSPECTION BY THE DISTRICT WILL BE CONSIDERED INVALID AND WILL NOT BE ACKNOWLEDGED. The connection must be made in conformity with the After connection is complete, the property described above is subject to a monthly sewer service charge, billed bi-monthly in advance. The rate will be governed by the use of the property, single family, multiple dwelling or commercial.. Non-payment of the sewer service charge is subject to a 5% penalty per month, plus disconnection if necessary. The undersigned hereby agrees that the above information given is correct and agrees to . 6/23/77 7623 Date Account No. CITY OF CARLSBAD BUILDING DEPARTMENT (714) 729-1 181 CERTI FlCATlON I certify that in the performance of the work for which this permit is issued I shall not employ any person in any manner so as to become subject to the workers’ compensation laws of California. If, after making this certificate, I become subject to the workers’ compensation pro- visions of the California Labor Code, I will forthwith comply with Section 3700 of the Labor Code, I understand that if I fail to comply with the workers‘ compensation laws, this permit shall be deemed revoked. I further certify that if I should contract or subcontract with any person, including any firm or company, to do all or part of the work for which this permit is issued, I shall assure compliance by that contractor or subcontractor with Section 3800 of the California Labor Code. SIGNE PRINT NAME AND TITLE: JOB ADDRESS:^& DATED: ?