HomeMy WebLinkAbout2840 LOKER AV EAST; ; CB013625; Permit12-31-2001
City of Carlsbad
1635 Faraday Av Carlsbad, CA 92008
Commercial/Industrial Permit Permit No: CB013625
Building Inspection Request Line (760) 602-2725
Job Address
Permit Type
Parcel No
Valuation
Occupancy Group
Project Title
12/17/2001
2840 LOKER AV EAST CBAD
Tl Sub Type INDUST
2090820800 Lot # 0
$10,00000 Construction Type NEW
Reference #
SELTZER CHEMICAL- RACK SYSTEM
Applicant
HALL STEVE
210
777SHWY101
SOLANA BEACH CA 92075
858-481-4141
Status
Applied
Entered By
Issued
Inspect Area
Owner
FENTON H G CO
7588 METROPOLITAN DR
SAN DIEGO CA 92108
ISSUED
11/21/2001
JM
Plan Approved
12/20/2001
7880 12/31/01 0002 01 02
CGP 101-59
Total Fees $16659 Total Payments To Date „ $65 00 Balance Due $101 59
Building Permit
Add! Building Permit Fee
Plan Check
Add'l Plan Check Fee
Plan Check Discount
Strong Motion Fee
Park Fee
LFM Fee
Bridge Fee
BTD #2 Fee
BTD #3 Fee
Renewal Fee
Add'l Renewal Fee
Other Building Fee
Pot Water Con Fee
Meter Size
Add'l Pot Water Con Fee
Reel Water Con Fee
, $99 69 Meter Size
/ $0 00 • Add'l Reel Water Con Fee
' ' $64 80 Meter Fee
$000 SDCWAFee'i •
$0 00 CFD Payoff Fee
$2 10 -PFF
$0 00 PFF (CFD Fund)
$0 00 License Tax
$0 00 License Tax (CFD Fund)
$0 00 Traffic Impact Fee
$0 00 - Traffic Impact (CFD Fund)
$0 00 PLUMBING TOTAL
$0 00 ELECTRICAL TOTAL
- $0 00 MECHANICAL TOTAL
$0 00 Master Drainage Fee
Sewer Fee
$0 00 Redev Parking Fee
$0 00 Additional Fees
TOTAL PERMIT FEES
$000
$000
$000
$000
$000
$000
$000
$000
$000
$000
$000
$000
$000
$000
$000
$000
$000
$16659
FINAL APPROVAL
Inspector Date # <L.Clearance
NOTICE Please lake NOTICE that approval of your prefect includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively
referred to as 'lees/exactions" You have 90 days from the date this permit was issued to protest imposition of these fees/exactions If you protest them, you must
follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for
processing in accordance with Carlsbad Municipal Code Section 3 32 030 Failure to timely follow that procedure will bar any subsequent legal action to attack,
review, set aside, void, or annul their imposition
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capactiy
changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project NOR DOES IT APPLY to any
fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired
J
PERMIT APPLICATION
CITY OF CARLSBAD BUILDING DEPARTMENT
1635 Faraday Ave , Carlsbad, CA 92008
FOR OFFICE USE ONL
PLAN CHECK
EST VAL
Plan Ck Deposit*
Validated By. /
fex
// /
Date
Address (include Bldg/Suite #)Business Name (at this address)
Legal Description Lot No Subdivision Name/Number Unii,No Phase No Total * of units
01 <P
Assessor's Parcel #Existing Use
JMA
Proposed Use 65-00
of SQ FT #of Stones edrooms
Name Address City State/Zip Telephone #
is SfcoNTRA!cfonT;coMi^
(Sec 7031 5 Business and Professions Code Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure prior to its
issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor s License Law
[Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Codel or that he is exempt therefrom, and the basis for the alleged
exemption Any violation of Section 7031 5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars [5500])
.»•.. J-
City State/Zip
City Business License #
Workers' Compensation Declaration I hereby affirm under penalty of perjury one of the following declarations
Q~~ I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance
of the work for which this permit is issued
(31 I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is
issued My worker's compensation insurance carrier and policy number are
Insurance Company 5T/jy_Tt= Ce?f>"i0<&^j$A.Tct V //H^n/frf^ctg A>'<£Policy No 3.JJXT -O^ - 6<^gQ"1^5 Expiration Date \ I ^ |QrX-j'
(THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS [S1001 OR LESS)
Q CERTIFICATE OF EXEMPTION I certify that in the performance of the work for which this permit is issued I shall not employ any person in any manner so as
to become subject to the Workers' Compensation Laws of California
WARNING Failure to secure workers compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred
thousand dollars ($100 QOOf, tn additfSi to in* cost of compensation damages as provided for in Section 3703 of the Labor code interest and attorneys fees
DATE \£.\*(]o\
~»-™*TywT«'-TiT»«p*j.;.li— •<?•*««•—<F™*'*,
i<-,^BL ™L i'i s Hi. MblL *L
hereby affirm that I am exempt from the Contractor s License Law for the following reason
Q I, as owner of the property or my employees with wages as their sole compensation, will tio the work and the structure is not intended or offered for sale
(Sec 7044, Business and Professions Code The Contractor's License Law does not apply to an Owner of property who builds or improves thereon and who does
such work himself or through his own employees, provided that such improvements are not intended or offered for sate If, however, the building or improvement is
sold within one year of completion, the owner-builder will have the burden of proving that he did ntjt build or improve for the purpose of sale)
Q 1, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec 7044, Business and Professions Code The
Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed
pursuant to the Contractor's License Law)
0 I am exempt under Section Business and Professions Code for this reason
1 I personally plan to provide the major labor and materials for construction of the proposed property improvement Q YES QNO
2 1 (have / have not) signed an application for a building permit for the proposed work
3 I have contracted with the following person (firm) to provide the proposed construction (include name / address / phone number / contractors license number)
4 I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone
number / contractors license number)
5 I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone number / type
of work)
PROPERTY OWNER SIGNATURE
fCOMRLETE fTHJS
DATE
Bufi5iNoreRfififsoH^^
Is the applicant or future building occupant required to submit a business plan acutely hazardous materials registration form or risk management and prevention
program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? Q YES D NO
Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district7 d YES Q NO
Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? O ^ES Q NO
IF ANY OF THE ANSWERS ARE YES A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE
REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT
[aTfcoNsTRucrTaTil^^
I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec 3097(0 Civil Code)
LENDER'S NAME LENDER'S ADDRESS ^
r: ~"f MHiT "*«r if^g"r"pTp^^^ w" •;""" "' -i'• M ' r r** w K""r.|f *" ".•'»•*&• *?" •rear'jr' '"'ft"f "Trrmr|r?r|fft!i^g"iJ'*^^mJi: - ;•«'-;*' \rn--> • *•,> •«• -f',^^rO^STCST^^'K «l. V^uTtZu Ml,sh)W&£*j4JllUi'Sl&iiAj;luijlii^inaiElkite!',/jLLV-f'.^«
I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate I agree to comply with all
City ordinances and State laws relating to building construction I hereby authorize representatives of the CilV of Carlsbad to enter upon the above mentioned
property for inspection purposes I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES,
JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT
OSHA An OSHA permit is required for excavations over 5'0" deep and demolition or construction of structures over 3 stones in height
EXPIRATION Every permit issued by the building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work
authorized by such permit is not commenced within 180 days from the date of such permit or if the building or work authorized by such permit is suspended or abandoned
at any time alter the work is corrtrrienced for a period ot 180 days (Section 106 4 4 Uniform Building Code)
APPLICANT'S SIGNATURr Imp- tW <2GLfc2£&~. /^ti^ft^W . . DATE C\
WHITE File YELLOW Applicant PINK Finance
City of Carlsbad Bldg Inspection Request
For 01/14/2002
Permit# CB013625
Title SELTZER CHEMICAL- RACK SYSTEM
Description
Inspector Assignment
2840 LOKER AV EAST
Lot 0
Type Tl
Job Address
Suite
Location
APPLICANT HALL STEVE
Owner FENTON H G CO
Remarks PALLET RACKS
Sub Type INDUST
Phone 8582072877
Inspector
Total Time
CD Description Act Comments
14 Frame/Steel/Bolting/Welding
Requested By TOM
Entered By KAREN
Date
Associated PCRs
PCR01044 ISSUED
PCR99204 ISSUED
Inspection History
Description Act Insp Comments
EsGil Corporation
In 'Partnership with government for
DATE 12/14/O1
JURISDICTION Carlsbad a PLAN REVIEWER
a FILE
PLAN CHECK NO 01-3625 SET II
PROJECT ADDRESS 2840 Loker Ave. East
PROJECT NAME Storage Racks for Seltzer Chemical
The. plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes
X] The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff
The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck
The check list transmitted herewith is for your information The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck
The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person
The applicant's copy of the check list has been sent to
X] Esgil Corporation staff did not advise the applicant that the plan check has been completed
] Esgil Corporation staff did advise the applicant that the plan check has been completed
Person contacted Telephone #
Date contacted (by ) f , Fax #
Mail Telephone Fax In Person r /^
X] REMARKS 1 City to field verify that the pafe-of travel from the handicapped parking space to
the rack area and the bathroom serving the rack area comply with all the current disabled
access requirements 2 Fire Departme/ri approval is required
By David Yao .; Enclosures
Esgil Corporation
D GA ID MB D EJ D PC 12/7 trnsmtldot
9320 Chesapeake Drive, Suite 208 * San Diego, California 92123 + (858)560-1468 * Fax (858) 560-1576
EsGil Corporation
In 'Partnership with Qove.Tnme.nt for $wO(ing Safety
DATE 12/4/01
JURISDICTION Carlsbad a PLAN REVIEWER
a FILE
PLAN CHECK NO 01-3625. SET I
PROJECT ADDRESS 2840 Loker Ave. East
PROJECT NAME Storage Racks for Seltzer Chemical
The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes
The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff
The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck
X] The check list transmitted herewith is for your information The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck
The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person
X] The applicant's copy of the check list has been sent to
Steve Hall 777S Hwy 101, Solana Beach, CA
Esgil Corporation staff did not advise the applicant that the plan check has been completed
X] Esgil Corporation staff did advise the applicant that the plan check has been completed
Person contacted Steve Hall LlVA Telephone # (858)481-4141
Date contacted p(u( (by 13 ) Fax # (858)481-8034
Mailx Telephone Fax— In Person
REMARKS
By David Yao Enclosures
Esgil Corporation
D GA D MB D EJ D PC H/26 trnsmtldot
9320 Chesapeake Drive, Suite 208 * San Diego, California 92123 4 (858)560-1468 4 Fax (858) 560-1576
•-* Carlsbad 01-3625
12/4/01
GENERAL PLAN CORRECTION LIST
JURISDICTION Carlsbad PLAN CHECK NO O1-3625
PROJECT ADDRESS 2840 Loker Ave. East
DATE PLAN RECEIVED BY DATE REVIEW COMPLETED
ESGIL CORPORATION 11/26 12/4/01
REVIEWED BY David Yao
FOREWORD (PLEASE READ):
This plan review is limited to the technical requirements contained in the Uniform Building Code,
Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws
regulating energy conservation, noise attenuation and disabled access This plan review is
based on regulations enforced by the Building Department You may have other corrections
based on laws and ordinances enforced by the Planning Department, Engineering Department
or other departments
The following items listed need clarification, modification or change All items must be satisfied
before the plans will be in conformance with the cited codes and regulations Per Sec 106 4 3,
1997 Uniform Building Code, the approval of the plans does not permit the violation of any
state; county or city law
Please make all corrections on the original tracings, as requested in the correction fist
Submit three sets of plans for commercial/industrial projects (two sets of plans for
residential projects) For expeditious processing, corrected sets can be submitted in one of
two ways
1 Deliver all corrected sets of plans and calculations/reports directly to the City of
Carlsbad Building Department, 1635 Faraday Ave , Carlsbad, CA 92008, (760) 602-2700
The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering
and Fire Departments
2 Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320
Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468 Deliver all
remaining sets of plans and calculations/reports directly to the City of Carlsbad Building
Department for routing to their Planning, Engineering and Fire Departments
NOTE Plans that are submitted directly to EsGil Corporation only will not be reviewed by
the City Planning, Engineering and Fire Departments until review by EsGil Corporation is
complete
• To facilitate rechecking, please identify, next to each item, the sheet of the plans upon
which each correction on this sheet has been made and return this sheet with the
revised plans
Carlsbad 01-3625
12/4/01
• Please indicate here if any changes have been made to the plans that are not a result of
corrections from this list If there are other changes, please briefly describe them and where
they are located on the plans Have changes been made not resulting from this list?
Q Yes a No
1J Carlsbad O1-3625
12/4/01
1 Provide a rack layout plan showing the location of all racks (Please specify on the plan
which one is type palter? Which one is mterlake?)
2 Only the storage racks are included in this plan review
3 Provide a statement on the Title Sheet of the plans that this project shall comply with
Title 24
4 City to field verify that the path of travel from the handicapped parking space to the rack
area and the bathrooms serving the rack area comply with all the current disabled
access requirements
5 Obtain Fire Department approval for groups F, M and S occupancy storage per UBC
Sections 306 8, 309 8 and 311 8
6 Indicate the clearance from the new racks to the existing building walls and building
columns
7 Note on the plans that the rack design loads will be posted per Section 2222 5
8 Provide forklift protection per Section 2222 5(or check the exception)
9 The calculation provided is for interlake rack only Please provide additional calculation
to show the palter rack is adequate to support the proper load
Recheck the "pallet" racks as follows:
10 Recheck all connections on sheet 01-1557A, 01-1557B as follows
a) The rivet bearing capacity is only dtFu = 0 406(0 0747)65 = 2 kips
b) Provide calculations for all beam to bracket weld capacities per Section 2330
(allowable weld stress is the member thickness times 26 ksi times 1 33, or the
weld stress, whichever is lower)
c) Check the bracket maximum weak axis moment
11 Provide calculations for the column weak axis bending plus axial for transverse seismic
loading The axial load is the maximum compression load at the base from vertical plus
seismic overturning The column moment will probably be maximum for the lateral load
from the base plate to the first diagonal brace (not only to the first horizontal member)
12 The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake
Drive, Suite 208, San Diego, California 92123, telephone number of 619/560-1468, to
perform the plan review for your project If you have any questions regarding these plan
review items, please contact David Yao at Esgil Corporation Thank you
Carlsbad 01-3625
12/4/01
VALUATION AND PLAN CHECK FEE
PLAN CHECK NO 01-3625
DATE 12/4/01
JURISDICTION Carlsbad
PREPARED BY David Yao
BUILDING ADDRESS 2840 Loker Ave. East
BUILDING OCCUPANCY TYPE OF CONSTRUCTION
BUILDING
PORTION
storage racks
Air Conditioning
Fire Sprinklers
TOTAL VALUE
Jurisdiction Code
AREA
( Sq Ft )
cb
Bldg Permit Fee by Ordinance "V
Valuation
Multiplier
By Ordinance
Reg
Mod
per city
VALUE ($)
10,000
10,000
$99.69
Plan Check Fee by Ordinance
Type of Review
Repetitive Fee
~T] Repeats
Complete Review
D Other
D Hourly
Structural Only
Hour
Esgil Plan Review Fee
Comments
$6480
$55.83
Sheet 1 of 1
macvalue doc
PLANNING/ENGINEERING APPROVALS
PERMIT NUMBER CB
ADDRESS Laker
DATE!of
RESIDENTIAL
RESIDENTIAL ADDITION MINOR
« $10,000.00)
TENANT IMPROVEMENT
PLAZA CAMINO REAL
CARLSBAD COMPANY STORES
VILLAGE FAIRE
COMPLETE OFFICE BUILDING
OTHER Pa lief"
PLANNER
ENGINEER
DATE
DATE
Docs/Misforms/Plannmg Engineering Approvals
Carlsbad Fire Department 013619
1635 Faraday Ave
Carlsbad, CA 92008
Plan Review Requirements Category:
Date of Report 12/12/2001
Fire Prevention
(760) 602-4660
Building Plan
Reviewed by 0
Name
Address
Jack Smyer Architect
731 S Highway 101 Suite 1L
City, State Solana Beach CA 92075
Plan Checker
Job Name Christ Presbyterian
Job# 013619
Job Address 7807 Centella Street
Bldg# CB013619
Ste orBldg No
r-7] Approved The item you have submitted for review has been approved The approval is
based on plans, information and / or specifications provided in your submittal,
therefore any changes to these items after this date, including field
modifications, must be reviewed by this office to insure continued conformance
with applicable codes and standards Please review carefully all comments
attached as failure to comply with instructions in this report can result in
suspension of permit to construct or install improvements
LJ Approved
Subject to
The item you have submitted for review has been approved subject to the
attached conditions The approval is based on plans, information and/or
specifications provided in your submittal Please review carefully all comments
attached, as failure to comply with instructions in this report can result in
suspension of permit to construct or install improvements Please resubmit to
this office the necessary plans and / or specifications required to indicate
compliance with applicable codes and standards
U Incomplete The item you have submitted for review is incomplete At this time, this office
cannot adequately conduct a review to determine compliance with the
applicable codes and / or standards Please review carefully all comments
attached Please resubmit the necessary plans and / or specifications to this
office for review and approval
Review
FD Job #
1 fit ?nd 3""^
013619 FDFile#
Other Aaency ID
aunaay, uectsmcet ju, *uw i
IftOMDOG
INSTALLATIONS
29303 WESTWIND DP • LAKE ELSINORE. CA 92330
PH (P09) 4W1.&92S •
December 30, 2001
To \Vhom it May Concern,
I, Tino Metzger, authorize Tom Woertz to act as my agent for the purpose of pulling
permits for Seltzer Chemical at 2840 Loker Avenue in Carlsbad, CA
Tino Mctzgcr
Owner
Irondog Installations
RECEIVED TIME DEC 5 56PM PRINT TIME DEC 30 5 58PM
, uecemoer JUP HO
PO BOX 420807. SAN FRANCISCO, CA 94142-0807
COMPENSATION
INSURANCE
FUND
r
CERTIFICATE OF
. BOX
EXPIRES -^
UNIT 002?7Vj
L
This Is to certify that we have issued a valid Workers' Compensation insurance policy in a form approved by the California
Insurance Commissioner to the employer named below far the policy period Indicated
This policy is not BuOject to cancellation by the Fund except upon ten days' advance written notice to the employer
We will also give you TEN days advance notice should this policy be cancelled prior to its normal expiration
This certificate of Insurance la not an insurance policy and does not amend, extend or alter the coverage afforded by the
policies listed herein _ Notwithstanding any requirement, ^erm, or condition of any contractor other document with
respect to which"this'certificate of'Insurance may "be tesited'or may pertam,"th«» insurants'afforded*by ths policies
described herein 1$ subject to all the Jen^a,iexctu3toYi'$'andconsfetiao& of Buch,po1icies '; -" ";& • • - 4
AUTHORIZED
rj (
r
tPOWOOh iMSTALt Aa^fr.S
2VSOJ3 WL^fUllyU D« "
L-^Xt Cl.'^NO1^ C1 92330
THIS DOCUMENT HAS A BLUE PATTERNED BACKGROUND ?(W [«FV, y-
RECEIVED TIME: DEC 5 TIME DEC 30 5 53PrT
Carlsbad Fire Department 013625
1635 Faraday Ave
Carlsbad, CA 92008
Plan Review Requirements Category:
Date of Report 12/12/2001
Building Plan
Reviewed by
Fire Prevention
(760) 602-4660
d.
Name
Address
CHAPO & HALL ARCH
777SHWY101
City, State SOLANA BEACH CA 92015
Plan Checker
Job Name Seltzer Chemical
Job# 013625
Job Address 2840 Loker Avenue East
Bldg# CB013625
Ste orBldg No
Approved The item you have submitted for review has been approved The approval is
based on plans, information and / or specifications provided in your submittal,
therefore any changes to these items after this date, including field
modifications, must be reviewed by this office to insure continued conformance
with applicable codes and standards Please review carefully all comments
attached as failure to comply with instructions in this report can result in
suspension of permit to construct or install improvements
LJ Approved
Subject to
The item you have submitted for review has been approved subject to the
attached conditions The approval is based on plans, information and/or
specifications provided in your submittal Please review carefully all comments
attached, as failure to comply with instructions in this report can result in
suspension of permit to construct or install improvements Please resubmit to
this office the necessary plans and / or specifications required to indicate
compliance with applicable codes and standards
LJ Incomplete The item you have submitted for review is incomplete At this time, this office
cannot adequately conduct a review to determine compliance with the
applicable codes and / or standards Please review carefully all comments
attached Please resubmit the necessary plans and / or specifications to this
office for review and approval
Review
FD Job #
1ct ?nr1 3rd
013625 FDFile#
Othfir Agency ID
MATERIAL HANDLING
EST 1985
SEIZMIC
ENGINEERING
RACKS
DRIVE^RACKS
&ANTILE^?ER RACKS
MEZZANINES
CONVEYORS
CAROUSELS
STEEL SHELVING
MOVABLE SHELVING
STORAGE TANKS
MODULAR OFFICES
GONDOLAS
BOOKSTACKS
CITY APPROVALS
STATE APPROVALS
PERMITTING SERVICES
PRODUCT TESTING
FIELD INSPECTION
S PEDAL FABRICATION
ALASKA
ARIZONA
CALIFORNIA
COLORADO
DAHO
MISSOURI
NEVADA
NEW MEXICO
OREGON
PENNSYLVANIA
UTAH
WASHINGTON
SEISMIC ANALYSIS
OF STORAGE RACKS FOR
SELTZER CHEMICAL
2840 LOKER AVE. EAST
CARLSBAD, CA.
#01-1557
161 ATLANTIC STREET • POMONA • CA 91768 • TEL (909)869-0989 FAX- (909)869-0981
SEIZMIC PROJECT.
FOR
SELTZER CHEMICAL
HAWTHORNE LIFT
SHEET NO OF.15
MATERIAL HANDLING ENGINEERING
TEL. (909)869-0989 » FAX (909J869-0981
161 ATLANTIC STREET • POMONA • CA 91768
CALCULATED BY_BOBS.DATE.10-04-01
TABLE OF CONTENTS
DESCRIPTION
COVER SHEET
TABLE OF CONTENTS
SCOPE
PARAMETERS
CONFIGURATIONS
COMPONENTS & SPECS.
LOADS AND DISTRIBUTION
LONGITUDINAL ANALYSIS
COLUMN
BEAM
BEAM TO COLUMN
BRACING
OVERTURNING
BASE PLATE
SLAB & SOIL
PAGE #
1
2
2
3
4 -4
5- 6
7
8
9
10
11
12
13
14
15
SCOPE:
THIS ANALYSIS OF THE STORAGE SYSTEM IS TO DETERMINE ITS COMPLIANCE WITH
THE APPROPRIATE BUILDING CODES WITH RESPECT TO STATIC AND SEISMIC FORCES.
THE STORAGE RACKS ARE PREFABRICATED AND ARE TO BE FIELD ASSEMBLED ONLY,
WITHOUT-ANY FIELD WELDING.
SEIZMIC PROJECT.
FOR
SELTZER CHEMICAL
HAWTHORNE LIFT
SHEET NO.OF.15
MATERIAL HANDLING ENGINEERING
TEL. (909)869-0989 • FAX. (909)869-0981
161 ATLANTIC STREET • POMONA • CA 91 768
CALCULATED BY.BOBS.DATE 10-04-01
PARAMETERS.
STORAGE RACKS CONSIST OF SEVERAL BAYS, INTERCONNECTED IN ONE OR BOTH
DIRECTIONS WITH THE COLUMNS OF THE VERTICAL FRAMES BEING COMMON BETWEEN
ANY ADJACENT BAYS
THE ANALYSIS WILL FOCUS ON A TRIBUTARY BAY TO BE ANALYZED IN BOTH
LONGITUDINAL AND TRANSVERSE DIRECTION
STABILITY LONGITUDINALLY IS DEPENDANT ON BEAM TO COLUMN MOMENT,
WHILE THE BRACING ACT TRANSVERSELY
1 COLUMN
2 BEAM
3 BEAM TO COLUMN
4. BASE PLATE
5 HORIZONTAL BRACING
6. DIAGONAL BRACING
7 BACK CONNECTOR
TRIBUTARY AREA
TRANSVERSE
LONGITUDINAL
TOP VIEW
SEIZMIC PROJECT SELTZER CHEMICAL
FOR HAWTHORNE LIFT
SHEET N0._OF.15
MATERIAL HANDLING ENGINEERING
TEL (909)869-0989 • FAX (909)869-0981
161 ATLANTIC STREET • POMONA • CA 91 768
CALCULATED BY BOBS. nATE 1Q-Q4-Q1
CONFIGURATIONS
TYPE PALTIER
60
180"60
60"
2,400 Ib
2,400 Ib
2,400 Ib
60"
60"
50"
94"44'^ 44"
TYPE INTERLAKE
2,400lb
60"62"
2,400 Ib
180"60'52"
3,400 Ib
60"52"
94"
SEIZMIC PROJECT.
FOR
SELTZER CHEMICAL
HAWTHORNE LIFT
SHEET NO OF.
MATERIAL HANDLING ENGINEERING
TEL: (909)869-0989 • FAX" (909)869-0981
161 ATLANTIC STREET • POMONA • CA 91768
CALCULATED BY_BOBS.DATE.10-04-01
TYPE PALTIER
SPECIFICATION
- MAIN STEEL , 55000 PSI
- BASE PLATE STEEL 36000 PSI
- ANCHOR - WEDGE TYPE 1 /Z x 3-1 /2
-FLOOR SLAB 5" X ZOOO PSI. REINFORCED 180"
- SOIL BEARING PRESSURE 1000 PSF
- SEISMIC ZONE 4.
- TYPE = INTERCONNECTED UNITS
2,400 Ib 269#342#
•
1*
6
;0" „6
~7
r
t —
>"
b[J"
•\
3
-
2,400 Ib
^
2,400 Ib
1
• n AH
i
6
179#
/
6
89#
5
f—
)"
)"
r
P"
y —
'
\\/
/
/
/
f. /I /I »
221•i ii E
1 V
,
SECTION AXIAL FORCE MOMENfr
lu= 94"
BEAM MOMENT
1 3,720 Ib. 7,812 in Ib. q
Z 2,480 Ib 6,735 in Ib *'
3 1,240 Ib - 4,041 in Ib V^"i
273 in.lb <-std.conn
388 in Ib. <-std conn.
020 in Ib <-std conn
TYPE PALTIER DESIGN LOAD « 2400#
BASE PLATE
V
6X6X.375
Mbase = 7812 in Ib.
OVERTURNING
V
ANCHOR STRESS = 0 09
# OF ANCHORS = 2
V
COLUMN
COLUMN
3X3X1 4GA(DX)
STRESS =0 65
MA)
BRACING
HORIZONTAL ^/
1-1/2X1X16GA
STRESS = 0 14
DIAGONAL
1-1/2X1X16G
STRESS = 0.4
BEAM
V3-1/2 x 2-3/4 x 14 ga
; LOAD/LEVEL = 4,457 Ib
BEAM IS O.K.
SLAB & SOIL
A V VA PUNCT. STRESS = 0 62
3 BENDING STRESS =0 61
SEIZMIC PROJECT.
FOR
SELTZER CHEMICAL
HAWTHORNE LIFT
SHEET NO OF.15
MATERIAL HANDLING ENGINEERING
TEL: (909)869-0989 • FAX" (909)869-0981
161 ATLANTIC STREET • POMONA • CA 91768
CALCULATED BY.BOBS.DATE.10-04-01
TYPE INTERLAKE
SPECIFICATION
- MAIN STEEL 55000 PSI
- BASE PLATE STEEL 36000 PSI
- ANCHOR - WEDGE TYPE 1/2 x 3-1 /Z
- FLOOR SLAB 5" X 2000 PSI REINFORCED 1 80"
- SOIL BEARING PRESSURE 1000 PSF
- SEISMIC ZONE 4
- TYPE = INTERCONNECTED UNITS.
2,400 Ib 269#342#
u
6
so- 6
)"
c —
)"
f,
60"I [f f
3
2,400 Ib
2
2,400 Ib
1
f n <t»
•"•••""•^
6
179#
5
89#
5
/
2"
)"
£
2"
f
///
\
' A A"
221— .^
1 1'
t
SECTION AXIAL FORCE MOMENT
lu= 94"
BEAM MOMENT
1 3,720 Ib. 7,812 m.lb
2 2,480 Ib. 6,735 m.lb
3 1,240 Ib. 4,041 m.lb
9,273 in
7,388 in
4,020 in
Ib <-std conn
Ib <-std.conn.
Ib. <-std.conn.
TYPE INTERLAKE DESIGN LOAD - 2400#
BASE PLATE
V
6X6X.375
Mbase = 7812 in Ib
OVERTURNING
ANCHOR STRESS = 0 09
# OF ANCHORS = 2
V
COLUMN
COLUMN
3X3X1 3GA(LU75)
STRESS =0.52
BEAM
V
3-21/32x2-3/4xl4GA/384H
MAX LOAD/LEVEL - 3 ,69 5 Ib.
BEAM IS O.K
BRACING
HORIZONTAL ^/
1 1/2 X 1-1/2 X 14 GA
STRESS = 0.10
DIAGONAL ^/
1 1/2 X 1-1/2 X 14 GA
STRESS = 0 28
SLAB & SOIL
V
PUNCT STRESS = 0 62
BENDING STRESS =0.61
SEIZMIC PROJECT.
FOR
SELTZER CHEMICAL
HAWTHORNE LIFT
SHEET N0._OF_15
MATERIAL HANDLING ENGINEERING
TEL. (909)869-0989 • FAX. (909)869-0981
161 ATLANTIC STREET • POMONA • CA 91 768
CALCULATED RY BOBS. n&TF 1Q-Q4-Q1
LOADS & DISTRIBUTION :TYPE INTERLAKE
1 ~ LIVE LOAD PER SHELF = Wll = 2,400 Ib
(BASED ON CLIENT SUPPLIED DATA)
DEAD LOAD PER SHELF = Wdl = 80 Ib
TOTAL LOAD PER FRAME = ' 7,440 Ibi' i
SEISMIC SHEAR BASED ON SECTION 1630.2.1 OF THE 1997 UBC
WHERE
^ V = ((2.5 x Ca x I) / R) x Wtotal '
Wtotal = (Wll/2 + Wdl) x n
n = # of shelves
Seismic Zone = 4
Ca== 0.44
R(long) = 5.6
R(trans) = 4.4
LQNGITUDIAL DIRECTION
= 1
Soil Coef. = Sd
Na= 1.0
Nv= 1.0
2,400 Ib 269#
n
6
JO" .D
6
0"
3"
:
3"
r*
3
2,400 Ib
2
2,400 Ib
' O 1"
• m
179#
89#
r
lu= 94"
342#
Vlong = (2.5 x 0.44 x 1 )/(5.6) x W) / 1.4
539 Ib w/ working stress reduction
Fi == VWhi / 2Wh
TRANSVERSE DIRECTION """•
Vtrans = (2.5 x 0.44 x 1 )/(4.4) x W / 1.4 s
= 686 Ib w/ working stre_ss reduction
52"
k—
Fi = VWhi / 2Wh 44"
228#
114#
SEIZMIC PROJECT.
FOR
SELTZER CHEMICAL
HAWTHORNE LIFT
SHEET NO.8 OF.15
MATERIAL HANDLING ENGINEERING
TEL. (909)869-0989 • FAX: (909)869-0981
161 ATLANTIC STREET • POMONA • CA 91768
CALCULATED BY BOBS.DATE 10-04-01
LONGITUDINAL ANALYSIS :TYPE INTERLAKE
THE ANALYSIS IS BASED ON THE PORTAL METHOD, WITH THE POINT OF CONTRA FLEXURE OF THE
COLUMNS ASSUMED AT MID-HEIGHT BETWEEN BEAMS, EXCEPT FOR THE LOWEST PORTION, WHERE
THE BASE PLATE PROVIDES ONLY PARTIAL FIXITY, THE CONTRA FLEXURE IS ASSUMED TO OCCUR
CLOSER TO THE BASE (OR AT THE BASE FOR PINNED CONDITION, WHERE THE BASE PLATE CANNOT
CARRY MOMENT),
Vlong = 2 * Vcol =
Vcof =
F 1 = 45 Ib.
F 2 = 90 Ib.
F3= 135lb.
539 Ib.
269 Ib.
EZ T
60 in.
60 in
I
b= 58 in
Beam toCol Conn
Col to slab
BASE PROVIDE PARTIAL FIXITY. SEE BASE PLATE SHT.
Mbase = 7812 in.lb.
Mupper + Mlower = Mconn'R' + Mconn'L'
Mconn'R' = Mconn'L1
Mconn * 2 = Mupper + Mlower
Mconn = [Mupper + Mlower]/2
Mupper
RESULTING FORCES ON COLUMN
SECTION
1
2
3
AXIAL LOAD
3720
2480
1240
MOMENT
7812
6734
4040
Mconn
9273
7387
SEIZMIC
• MATERIAL HANDLING ENGINEERING
TEL- (909)869-0989 • FAX- (909)869-0981
161 ATLANTIC STREET • POMONA • CA 91 768
PROJECT,
FOR
SELTZER CHEMICAL
HAWTHORNE LIFT
SHEET NO OF.15
CALCULATED BY.BOBS.DATE 10-04-01
COLUMN ANALYSIS :TYPE INTERLAKE
COLUMN IS ANALYZED PER AISI COLD-FORMED STEEL DESIGN MANUAL
Pmax - 3,720 Ib. Mmax = 7,812 m.lb.
Kxlx/rx = 1.2 * 59 / 1.229 = 57.6 <- GOVERNS
Ky!y/ry= 8*52/1.08= 38.5
Cc = (2TiA2E/Fy)A.5
= 102.0
SINCE Kl/r <= Cc,
Fa - .522Fy - [(kl/rfrFy)/1494]A2
= 24,212 psi.
fa = Pmax/Area
= 4,739 psi.
f b - Mmax/Sx
= 9,516 psi.
fa/Fa =0.20 >.15
F'e = 12TrA2E/23(Kxlx/rx)A2
F'e « 44,997 psi
Fb = .6*Fy = 33,000 psi.
Cm*fb/Fb[1-fa/F'e] =
COMBINED STRESS = 0.52
A
B
SECTION PROPERTIES
A=s» B = 3"
C= 75" D = 0"
E = 0" Wt. = 2 664#
tl = 09" t2 = 0"
Area = 785"A2
lx = l.lZ1nA4 ly- 917"M
Sx= 821"A3 Sy= 584"A3
rx = 1 229" ry= 1 08"
60"
59"
52"
52"
Front View Side View
PROJECT
FOR
SHEET NO.
SELTZER CHEMICAL
HAWTHORNE LIFT
OF 15
MATERIAL HANDLING ENGINEERING
TEL (909) 869-0989 • FAX (909) 869-0981
161 AUANTIC AVENUE- POMONA- CA91768
CALCULATED BY BOBS DATE 12/6/01
COLUMN ANALYSIS f3X3X1 3RA^ FXPOSFD POST P.HFCK
ANALYZED PER DIV VII, CHAP 22 OF THE 1 997 UBC SECTION PROPERTIES BASED ON THE EFFECTIVE SECTION
P= 3.720 LB _, *
M= 0 1N-LB A
1 KxLx/rx - 1 2*59 IN/1 229 IN ff ' ' " f f
= 57 6 <=== (Kl/r)max '•
KyLy/ry = 0 8*52 IN/1 08 IN ; t
OOC • ' •— Jo 5 ^- , +
AXIAL
Fe= nA2E/(KL/r)maxA2 (EQ C4 1 -1 )
= 87 7 KSI ;
Fy/2= 27 5 KSI (^3
SINCE, Fe > Fy/2
THEN, Fn= Fy(1-Fy/4Fe) (EQ C4-3)
f*1 i 1
1
1
B
,-^Jj r
= 55 KSI*[1-55 KSI/(4*87 7 KSI)] SECTION PROPERTIES
= 46.4 KSI
Pn= Aeff*Fn (EQ C4-2)
= 36,408 LB
f)c= 1 92
Pa= Pn/fic (EQC4-1)
= 36408 LB/1 92
- 18,963 LB
P/Pa= 0 20 > 0 1 5
FLEXURE
CHECK P/Pa + (Cmx*Mx)/(Max*j/x) < 1 33 (EQ C5-1)
P/Pao + Mx/Max < 1 33 (EQ C5-2)
Pno= Ae*Fy
= 0 785 INA2 *55000 PSI
= 43,1 75 LB
Pao= Pno/Oc
= 431 75 LB/1 92
= 22,487 LB
Myield=My= Sx*Fy
= 0 821 INA3 * 55000 PSI
= 45,155IN-LB
Max= My/Of
= 45155IN-LB/1.67
= 27,039 IN-LB
A= 3.0 IN
B= 3.0 IN
C= 0.75 IN
t = 0.0897 IN
Aeff = 0 785 INA2
lx= 1 121 INA4
Sx = 0.821 INA3
rx= 1 229 IN
ly = 0917 INA4
Sy = 0 584 INA3
ry = 1 080 IN
Kx= 1.2
Lx = 59.0 IN
Ky = 0 80
Ly = 52 0 IN
Fy= 55 KSI
E= 29,500 KSI
Of= 1 67
Cmx= 1.0
Cb= 1 0
Pcr= nA2EI/(KL)maxA2 u\= {1/[1-(Oc*P/Pcr)]}A-l
= nA2*29500 KSI/(1 2*59 IN)A2 = {1/[1-(1. 92*3720
= 65,112LB =0.89
THUS,
(3720 LB/1 8963 LB) + (1*0 IN-LB)/(27039 IN-LB*0 89) = 0 20 < 1
(3720 LB/22487 LB) + (0 IN-LB/27039 IN-LB) = 017 < 1
SINCE COLUMN IS LESS THAN HALF STRESSED,
IT IS OK FOR COLLISION LOADS (PER SECTION 2222 5)
LB/G5112 LB)]}A-i
0, OK (EQC5-1)
0, OK (EQ C5-2)
PROJECT
FOR
SHEET NO.
SELTZER CHEMICAL
HAWTHORNE LIFT
OF 15
MATERIAL HANDLING ENGINEERING
TEL (909) 869-0989 - FAX (909) 869-0981
161 ATLANTIC AVENUE- POMONA- CA 91768
CALCULATED BY BOBS.DATE 12/6/01
COLUMN ANALYSIS (3X3X130^ DOWN AISI F 1 OARS
ANALYZED PER
p_
M-
KxLx/rx —
KyLy/ry =
AXIAL
Fe=
=
Fy/2=
SINCE, Fe
THEN, Fn=
11 ' — ••'"•' — ...«•• • • » f _...._ — — _
DIV VII, CHAP 22 OF THE 1 997 UBC SECTION PROPERTIES BASED ON THE EFFECTIVE SECTION
3,720 LB
7,81 2 IN-LB ' |— i- — ' *
1 2*59 IN/1 773 IN v t i r r r
57 6 <=== (Kl/r)max
08*52 IN/1 .08 IN t
38 5 ._ -«
nA2E/(KL/r)maxA2 ' (EQ C4 1 -1 )
87 7 KSI
27.5 KSI IJ^
>Fy/2
Fy(1-Fy/4Fe) (EQ. C4-3)
A *-l^
'; J,
B
•
*J v
= 55 KSI*[1-5S KSI/(4*87 7 KSI)J SECTION PROPERTIES
=
Pn=
=
nc=
1
Pa=
=
=
P/Pa=
FLEXURE
CHECK-
Pno=
=
=
Pao=
=
=
Myteid=My=
=
=
46 4 KSI
Aeff*Fn (EQ C4-2)
36,408 LB
1 92
Pn/Oc (EQC4-1)
36408 LB/1. 92
1 8,963 LB
0.20 > 0 1 5
P/Pa + (Cmx*Mx)/(Max*//x) < 1 33 (EQ C5-1)
P/Pao + Mx/Max < 1 33 (EQ C5-2)
Ae*Fy
0.785 IN^2 *55000 PSI
43,1 75 LB
Pno/Oc
431 75 LB/1 92
22,487 LB
Sx*Fy
0.821 INA3 * 55000 PSI
45,155 IN-LB
A= 3 0 IN
B= 3 0 IN
C= 0 75 IN
t = 0.0897 IN
Aeff = 0.785 1NA2
lx= 1 121 INA4
Sx= 0821 IN A3
rx = 1 229 IN
Iv = 0 917 INA4ijr \J %j I I n i T^
Sy = 0 584 INA3
ry = 1.080 IN
Kx= 1 2
Lx = 59 0 IN
Ky - 0 80
Ly = 52 0 IN
Fy= 55 KSI
E= 29,500 KSI
Qf= 1 67
Cmx= 1 0
THUS,
Max= My/Of
= 45155 IN-LB/1 67
= 27,039 IN-LB
Pcr= nA2EI/(KL)maxA2 ^
= nA2*29500 KSI/(1 2*59 IN)*2
= 65,112 LB
(3720 LB/18963 LB) + (1*7812 IN-LB)/(27039 IN-LB*0 89)
! (3720 LB/22487 LB) + (7812 IN-LB/27039 IN-LB)
Cb= 1.0
{1/[1-(O.c*P/Pcr)]}A-1
{1/[1-(1.92*3720 LB/65112 LB)]}A-l
089
052 <1 33, OK (EQC5-1)
045 < 1 33, OK (EQC5-2)
PROJECT
FOR
SHEET NO.
SELTZER CHEMICAL
HAWTHORNE LIFT
OF 15
MATERIAL HANDLING ENGINEERING
TEL (909) 869-0989 - FAX (909) 869-0981
161 ATLANTIC AVENUE- POMONA- CA 91768
CALCULATED BY BOBS DATE 12/6/01
COLUMN ANALYSIS (3X3X13GA) CROSS AISLE LOADS
ANALYZED PER DIV VH, CHAP 22 OF THE 1997 UBC SECTION PROPERTIES BASED ON THE EFFECTIVE SECTION
Pstatic= 3,720 LB
Pseismic= 110399IN-LB/44IN
= 2,509 LB
Ptotal= 6,229 LB
My= V*h
= 686 LB * 7 IN
= 4,802 IN-LB
KxLx/rx = 1 2*59 IN/1 229 IN
Pcol
= 576
KyLy/ry = 0 8*52 IN/1 08 IN
= 385
<=== (Kl/r)max
SIDE ELEVATION
AXIAL
SINCE,
THEN.
Fe= nA2E/(KL/r)maxA2
= 87.7 KSI
Fy/2= 27 5 KS!
Fe > Fy/2
Fn= Fy(1-Fy/4Fe)
= 55 KSI*[1-55 KSI/(4*87 7 KSI)]
= 46 4 KSI
Pn= Aeff*Fn
= 36,408 LB
Oc= 1 92
Pa= Pn/nc
= 36408 LB/1 92
= 18,963 LB
P/Pa= 033 > 015
FLEXURE
CHECK P/Pa + (Cmx*Mx)/(Max*j/x) < 1 33
P/Pao + Mx/Max < 1 33
Pno= Ae*Fy
- 0.785 INA2 *55000 PSI
= 43,175 LB
Pao= Pno/Oc
= 43175 LB/1.92
= 22,487 LB
Myield=My= Sy*Fy
= 0.584 INA3 * 55000 PSI
= 45,1 55 IN-LB
Max= My/Of
= 45155IN-LB/1 67
= 27,039 IN-LB
Pcr= nA2El/(KL)maxA2
= TiA2*29500 KSI/0 2*59 IN)A2
= 65,112 LB
(EQC41-1)
(EQ C4-3)
(EQ C4-2)
(EQC4-1)
(EQC5-1)
(EQ C5-2)
V= 686 LB
Mseismic= 110,399 IN-LB
h= 7 IN
DEPTH= 44 IN
SECTION PROPERTIES
A= 3.0 IN
B= 3.0 IN
C= 0 75 IN
t = 0 0897 IN
Aeff = 0 785 INA2
lx= 1 121 INA4
Sx = 0821 INA3
rx = 1 229 IN
ly = 0.917 INA4
Sy = 0 584 INA3
ry = 1 080 IN
Kx- 1.2
Lx = 59 0 IN
Ky = 0 80
Ly = 52 0 IN
Fy= 55 KSI
E= 29,500 KSI
Df= 1 67
Cmx= 1 0
Cb= 1 0
ux= {1/[1-(Oc*P/Pcr)]}A-l
1 92*6229 LB/65112 LB)]!A-1
THUS, = 0 82
(6229 LB/18963 LB) + (1*4802 IN-LB)/(27039 IN-LB*0.82) = 0.55 < 1 33, OK
(6229 LB/22487 LB) + (4802 IN-LB/27039 iN-LB) = 0 45 < 1 33, OK
(EQC5-1)
(EQ C5-2)
SEIZMIC PROJECT.
FOR
SELTZER CHEMICAL
HAWTHORNE LIFT
SHEET NO 10A OF.15
MATERIAL HANDLING ENGINEERING
TEL. (909)869-0989 • FAX: (909)869-0981
161 ATLANTIC STREET • POMONA • CA 91 768
CALCULATED BY_BOBS.DATE.10-04-01
BEAM ANALYSIS :TYPE INTERLAKE
BEAM TO COLUMN CONNECTIONS PROVIDE ADEQUATE MOMENT CAPACFTY TO STABL1ZE THE SYSTEM,
ALTHOUGH IT DOES NOT PROVIDE 100% FIXITY THUS, THE BEAMS WILL BE ANALYSED ASSUMING
THEY HAVE PINNED ENDS. FOR THE COMPUTATION OF BEAM TO COL MOMENT CAPACITY, THE
PARTIAL FIXITY OF THE BEAM,(ASSUMED AT AN ARBITRARY 25% OF THE FIXED END MOMENT OR
Z,000 in.lb WHICH EVER IS SMALLER) WILL BE ADDED.
. 275"
r-1.75"— |
t = 0747 in
11 625"
1
Sx = 0 740 in AS
lx= 1.441 in.M
I act - 94.0 in.
I max = [1950 + 1200(M1/M2)]b/Fy
SINCE Ml/M2 = 1-0
lmax = 3150*b/Fy = 158 in.
SINCE imax > lact Fb = ,60Fy = 33,000 psi.
MAXIMUM STATIC LOAD PER LEVEL DEPENDS ON 3.655"
1) BENDING CAPACITY
M = Sx* Fb = w|A2/8
= 24420m.lb.
CAPACITY = 2(8*M/I) = 3694lb.
2) MAXIMUM ALLOWABLE DEFLECTION (L/1 80)
A= 5w|A4/384EI
CAPACITY = 2[(384EI)/(5*180*1A2)] = 4105lb.
MAXIMUM STATIC LOAD PER LEVEL IS 3,695 Ib.
ALLOWABLE AND ACTUAL BENDING MOMENT AT EACH LEVEL
Mstatic = wlA2/8 - LIVE LOAD*L/(2*8) Mallow(static) = Sx * Fb
Mimpact = 1 1 25*Mstatic Mallow(seismic) = 1.33 * Sx * Fb
Mseismic = Mconn (SEE LONG. ANALYSIS)
LEVEL Mstatic Mimpact Mallow Mseismic Mallow RESULT
ii25Mstatic (static) (seismic)
1 14100 15862 24420 9273 32559 GOOD
2 14100 15862 24420 7387 32559 GOOD
3 14100 15862 24420 4020 32559 GOOD
PROJECT
FOR
SHEET NO.
SELTZER CHEMICAL
HAWTHORNE LIFT
OF 15
MATERIAL HANDLING ENGINEERING
TEL (909)869-0989 • FAX (909) 869-0981
161 ATLANTIC AVENUE- POMONA- CA91768
CALCULATED BY BOBS DATE 12/6/01
STEP BEAM WELD SECTION PROPERTIES & CAPACITIES
SCOPE-
DETERMINE THE EFFECTIVE SE(
BELOW THE EFFECT OF THE R
~~ ~ *~ ~~ ~\iii
i mm
:riON PROPERTIES OF THE MEMBER WELD SHOWN
OUNDED CORNERS ARE TAKEN INTO ACCOUNT1 1 h h
TYPE "A" WELD TYPE "B" WELD TYPE "C" WELD TYPE "D" WELD
BEAM ft WF| n INFO
tweld*= 01 25 IN
C WELD TYPE ^
TYPE "A" WELD *V
\L — — • __ — _Jy
A
WELD SECTION PROPERTIES
0-125 INCH THICK, TYPE "A"
AREA- 0711 INA2 N
Sx= 0 33 IN A3
WELD
FOMENT CAPACITY= 9,278 IN-LB -1
EFFECTIVE SECTION PROPERTY FOR WELD
ELEMENT | WIDTH
— t— -j- E— |
1
t
f
\ '•
CG ; F I
Y-BAR
i \
* — B •-
HEIGHT | Y-BAR ELEM | AREA | Y-BAR | 1 |
1 0 0000 IN 0 0000 IN 0 0000 IN 0 0000 (NA2 0 0000 JNA4
2 0 1 250 IN 3 6550 IN 1 8275 IN 0 4569 INA2 0 5471 INA4
3 0 0000 IN 0 0000 IN 0.0000 IN 0.0000 INA2 0 0000 INA4
4 00000 IN 00000 IN 0 0000 IN 0 0000 IN*2 0 0000 INA4
5 0 0000 IN 0 0000 IN 0 0000 IN 0 0000 INA2 0 0000 INA4
6 0 1 250 IN 2 0300 IN 1 01 50 IN 0.2538 INA2 0 1 564 INA4
£AREA= 071 06 IN A2
y bar= 1 537 IN
lx= 0 7035 INA4
WELD MOMF.NT CAPACITY UNDER SEISMIC LOADING
CAPACTTY= 0 3 * Fu * Sx-weld * 1 33
= 03* 70000 PSI * 0 332 INA3 * 1 .33
= 9,278 IN-LB
PROJECT
FOR
SHEET NO.
SELTZER CHEMICAL
HAWTHORNE LIFT
11 OF 15
MATERIAL HANDLING ENGINEERING
TEL (909)869-0989 • FAX (909)869-0981
161 ATLANTIC AVENUE- POMONA- CA 91768
CALCULATED BY BOBS DATE 12/6/01
BEAM TO COLUMN ANALYSIS: INTERLAKE STANDARDH 3GA COLUMNS
Mconn max= Mconn- seismic + Mend
= |9,273 IN-LB 1
CONNECTION CAPACITY DEPENDS ON THE FOLLOWING PARAMETERS
1) SHEAR CAPACITY OF STUDS
STUD DIAMETER= 7/16 IN
Fy- 55,000 PSI
Pmax-shear= 0 4 * Fy * Area
= 04* 55000 PSI * (0 4375 IN)A2 * n/4
= 3,307.3 LB
2) BEARING CAPACITY ON COLUMN
Fu= 65,000 PSI
Pmax-brg= Bearing Area * Fbeanng
= (05* thickness) * (1 0 * Fu)
= (05* 0.0897 IN) * (1 0 *65000 PSI)
= 2,925 00 LB < 3307 3 LB
3) MOMENT CAPACITY OF BRACKET
Mconn
Mcap= Sbracket * Fbending
= 011 INA3 * 0.66 * Fy
= 3,993 IN-LB
C= Mcap/0.75 = 1.11 * PI
THUS, P1= 1.20*Mcap
= 4,792 IN-LB > 3307 3 LB
THUS, GOVERNING VALUE IS THE MIN VALUE OF PI,
P1-eff= 2,925 LB
Mconn-allow= P1*4 5 IN + P2*0 5 IN
= 455*P1-eff * 1 33
= 17,745 IN-LB > Mconn max, OK
3"
t=7 go
<- 1-5/8"
Mupper
Mconn
7)
V
Mlower
C= PI + P2
= P1+P1*(05/4.5)
= 1 11*P1
Sbracket= 0110 INA3
PROJECT.
FOR
SELTZER CHEMICAL
HAWTHORNE LIFT
SHEET NO 12 OF.15
MATERIAL HANDLING ENGINEERING
TEL: (909)869-0989 • FAX" (909)869-0981
161 ATLANTIC STREET • POMONA • CA 91 768
CALCULATED BY.BOBS.DATE_10-04-01
TRANSVERSE ANALYSIS : BRACING :TYPE INTERLAKE
IT IS ASSUMED THAT THE LOWER PANEL RESISTS THE FRAME SHEAR IN TENSION AND
COMPRESSION IF HORIZONTAL AND DIAGONAL MEMBERS ARE THE SAME, ANALYSIS WILL BE DONE
ON THE DIAGONAL MEMBER AS IT WILL GOVERN.
DIAGONAL BRACING : COMPRESSION MEMBER
L diag. = [(L-6)A2+(D-2*Bcol)A2]A.5
= 59.6
Vdiag =Vtrans * Ldiag. / D
= 929#
kl/rmin = [ 1 * 59.6] 7.495
= 120.5
Fa=[12nA2E]/[23(kl/r)A2]
= 10278 psi.
fa/Fa =Vdiag/(Area*Fa)
= 0.28
Dh= 59,6"
D= 44"
L= 52"
DIAGONAL AND
HORIZONTAL BRACING
W
H
Area= 325 "A2
rmm= 495 "
t= 0747 "
W- 1 5 "
H« 1 5 "
PROJECT,
FOR
SELTZER CHEMICAL
HAWTHORNE LIFT
SHEET NO 13 OF.15
MATERIAL HANDLING ENGINEERING
TEL. (909)869-0989 • FAX- (909)869-0981
161 ATLANTIC STREET • POMONA • CA 91 768
CALCULATED BY_BOBS.DATE.10-04-01
OVERTURNING :TYPE INTERLAKE
ANALYSIS OF OVERTURNING WILL BE BASED ON SECTION 222$ 7.1 OF THE 199?-Uniform Building
Coda - ,
FULLY LOADED
TOTAL SHEAR = 685 Ib.
~ '' Mot = Vtrans * ht * 1.15
, =685*160*1.15
= 110399 in.Ib.
Mst = Z(Wp+ 85wDL) * d/2
= ( 7200-K85 * 240) * 44/2
= 158400 in.Ib.
Puphft =1(Mot- Mst)/d
Puplift <= 0 NO UPLIFT
342#
62
52
TOP SHELF LOADED
SHEAR =228 !b.
Mot =Vtop*h * 1.15
= 228* 180* 1.15
= 47314 in.ib.
Mst - (Wp+wDL) * d/2
= ( 2400+.85 * 240) * 44/2
= 52800 in.Ib.
Puphft = 1(Mot- Mst)/d
Pupiift <= 0 NO UPLIFT
USE 2 ea. 1/2 x 3-1/2 MIN. EMBED. ANCHOR.
CAPACITY OF 1 /2 x 3-1 /2 = 875 Ib. PULLOUT & 1 840 Ib. SHEAR
COMBINED STRESS1 = 0 / 1750 + 342 / 3680 = 0.09
COMBINED STRESS2 = 0 / 1750 + 114 / 3680 = 0.03
44"-,
228#
1 14#
SEIZMIC PROJECT.,
FOR
SELTZER CHEMICAL
HAWTHORNE LIFT
SHEET NO 14 OF.15
MATERIAL HANDLING ENGINEERING
TEL: {909)869-0989 • FAX. (909)869-0981
181 ATLANTIC STREET • POMONA • CA 91768
CALCULATED BY_BOBS.DATE.10-04-01
BASE PLATE .TYPE INTERLAKE
BASE PLATE WILL BE ANALYZED WITH THE RECTANGULAR STRESS RESULTING FROM THE VERTICAL
LOAD P, COMBINED WITH THE TRIANGULAR STRESSES RESULTING FROM THE MOMENT Mb (IF ANY)
THERE ARE 3 CRITERIA IN DETERMINING Mb. THEY ARE 1) MOMENT CAPACITY OF THE BASE PLATE,
Z) MOMENT CAPACITY OF THE ANCHOR BOLTS, AND 3) Vh/Z (FULL FIXITY) Mb IS THE SMALLEST
VALUE OBTAINED FROM THE 3 CRITERIA ABOVE.
Pcol = 3720lb.
Mb- 7812 in.lb.
= 6 in.D = 6 in.
b«3 in.
t = .375 in
bl = 1.5 in.
P/A - Pcol/(D*B) = 103.3 psi.
M/S = Mb/((D*BA2)/6) = 217.0 psi.
fb2 = 2b/B*fb = 108.5 psi.
fbl =fb-fb2 - 108,5 psi.
Mbase = wb1 A2/2 = b!A2/2[ fa + fbl + .67fb2]
Mbase = 319 7 in ib.
Sbase = 1*tA2/6 = 0 0234 in.^3
Fbase = .75Fy * 1.33 - 36000 psi.
f b/Fb = Mbase/(Sbase*Fbase) = .37
ANCHOR TENSION
T*d2=[Mbase- Pcoi*b/2]
T = Mbase/d2 - Pco!*b/2d2
T = 637 Ib.
fb fbl
1/
T
Mbasef
dl I.id 9
_X"
Pcolr
T^x.
Mbase
^ b *r
- .rt3i.\ -a
d2
dl
dl
SEIZMIC PROJECT.
FOR
SELTZER CHEMICAL
HAWTHORNE LIFT
SHEET N0._15 OF.15
MATERIAL HANDLING ENGINEERING
TEL: (909)869-0989 • FAX" (909)869-0981
161 ATLANTIC STREET • POMONA • CA 91 768
CALCULATED BY.BOBS.DATE.10-04-01
SLAB AND SOIL .TYPE INTERLAKE
THE SLAB IS CHECKED FOR PUNCTURE STRESS IF NO PUNCTURE OCCURS, IT WILL BE ASSUMED TO
DISTRIBUTE THE LOAD OVER A LARGER AREA OF SOIL AND HENCE, WILL ACT AS A FOOTING
(a) PUNCTURE
Pmax
Pmax
Fpunct = 2*sqrt(f c)
Apunct - [(w+t/2)+(d+t/2)]*2*t
fv/Fv = Pmax/(Apunct*Fpunct)
1.4 DEAD LOAD + 1.7 LIVE LOAD
1.4*Pcol + 1.7 *(Mot/d)
9,473 Ib.
89.4 psi.
170.0 in.A2
0.62
(b) SLAB TENSION
Asoil = Pmax/(1.33 * fsoil) = 7.10 ft.A2
= 1,023in.A2
L = sqrt(Asoil) = 32.0 in.
B = sqrt(w*d) + t - 11.0 in.
b = (L-B)/2= 10.5 in.
Mconc = wbA2/2 = (1.33*fsoil*bA2)/(144*2)
= 509.8 m.lb.
Scone = 1*tA2/6 = 4.17 in AS
Fconc = 50 *sqrt(fc) » 201.25 psi.
f b/Fb = Mconc/(Sconc*Fconc) = 0.61
L
BASE PLATE
w = 6 in.
d = 6 in.
CONCRETE
t = 5 in.
f'c = 2000 psi.
SOIL
fs= 1000 psf.
• b ,
', - - '..^/>'/, 'f ' ',.„-
< R
t
,
/
I ' T "-L1. ' f
~ , S^ **f *• *i1 !
* ,A/
CJ
SELTZER CHEMICALS INC.: 2840 Loker Avenue/Suite 150, Carlsbad CA
UNIFORM/CALIFORNIA CODES ANALYSIS - ADDENDUM
Seltzer Chemicals Inc.
2840 Loker Avenue/Suite 150 - Carlsbad CA
Technical Report Addendum
Uniform/California Codes Analysis
Revised Storage Conditions - Room 129
Code Requirements & Conditions
19 November 2000
Prepared by
V Enksen-Rattan Associates Inc
4719 Palm Avenue
La Mesa, California 91941
Telephone 619 466 6285
FAX 619 466 6233
EMAIL Ma ryRattan@thecode resource com
This report is the property of Enksen-Rattan Associates Inc and was prepared exclusively for use by Seltzer Chemicals Inc [SCI]
for the operations described in this report Copies of this report retained by SCI shall be utilized only by SCI for occupancy
classification and the Uniform/California Code conditions addressed in this report
This report shall not be used for the purpose of construction for this project or any other project or for any other purpose
SELTZER CHEMICALS INC.: 2840 Loker Avenue/Suite 150, Carlsbad CA
UNIFORM/CALIFORNIA CODES ANALYSIS - ADDENDUM
OVERVIEW
Enksen-Rattan Associates Inc prepared this report for the exclusive use of Seltzer Chemicals Inc [SCI],
with the report prepared as an addendum to the 10-23-00 Technical Report prepared for SCI's operations
located in Suite 150 at 2840 Loker Avenue in Carlsbad, California This report addresses modifications to
warehouse storage conditions and operations [Room 129/Shippmg & Receiving] based on applicable
1997/1998 Uniform/California Code requirements and conditions Final plans and completed details for
SCI's revised warehouse storage operations will be determined based on the information provided in this
report
Seltzer Chemicals Inc is a manufacture of all-natural nutritional health and food supplements The
changes in Room 129 involve increasing rack storage height from 12' to 20' above the finished floor for
Class I-IV Commodities and use of a battery-powered industrial truck [forklift] and battery-charging
operations
Hazardous materials Control Area conditions for SCI's portion of the building will not impacted by the
change in storage conditions as the materials that will be stored are not regulated through the Codes by
amount [unlimited Exempt Amount] in a fully sprinklered building
Existing conditions within Room 129 will not have to be changed, provided the following conditions are in
place and maintained
* The fire sprinkler design conditions for Room 129 identified in the 10-23-00 Technical
Report are in place
+ There is either no shelving in the racks, or only open metal mesh/grated shelving is used
in the racks in accordance with the conditions indicated in Table 2 OB
* Aisles >/=8* are provided between racks
» High Hazard Commodities packaging materials [plastics] are not stored in racks and are
not stored higher tan 5 5' above the finished floor
The report is organized as follows
4Ni", Section
1 0
20
Table 2 OA
Table 2 OB
r»l ' F'.^ fs>^"C' -lA i 1 Subject ' "- , J * J ','' , „.« . f " , :;.
Scope
Room 129 - Modifications to Storage Conditions & Operations
Room 129 Storage Conditions & Operations - Modifications
Code Requirements & Conditions
Page(s)^
1
2-6
3-4
5-6
Plans associated with SCI's operations will be provided separately through Chapo & Hall Architects, with
final plans and completed details for SCI's operations will be determined based on the information
provided in this report Review of such plans for the conditions and requirements addressed herein is
outside the scope of this report
SELTZER CHEMICALS INC.: 2840 Loker Avenue/Suite 150, Carlsbad CA
UNIFORM/CALIFORNIA CODES ANALYSIS - ADDENDUM
INFORMATION
Questions concerning Seltzer Chemicals Inc operations should be directed to
Seltzer Chemicals Inc
Clyde Seltzer - Chief Engineer
5927 Geiger Court
Carlsbad, California 92008-7305
Telephone 760 438 0089
FAX 760 438 0336
EMAIL clyed@seltzerchemicals com
Questions concerning tenant improvement plans and documentation for this project should be directed to
Chapo & Hall Architects
Stephen Hall
777 South Highway 101 -Suite 210
Solana Beach, California 92075
Telephone 858 481 4141
FAX 858 481 8034
EMAIL chaphall@pacbell net
Questions concerning this report should be directed to
VEnksen-Rattan Associates Inc
Mary Enksen-Rattan
4719 Palm Avenue
La Mesa, California 91941
Telephone 619 466 6285
FAX 619 466 6233
EMAIL MaryRattan@thecoderesource com
Discrepancies between this report and actual plan and field conditions are the sole responsibility of Seltzer
Chemicals Inc
SELTZER CHEMICALS INC.: 2840 Loker Avenue/Suite 150, Carlsbad CA
UNIFORM/CALIFORNIA CODES ANALYSIS - ADDENDUM
TECHNICAL REPORT ADDENDUM
REVISED STORAGE CONDITIONS - ROOM 129
CODE REQUIREMENTS & CONDITIONS
1.0 Scope
Enksen-Rattan Associates Inc prepared this report for the exclusive use of Seltzer Chemicals Inc [SCI],
with the report prepared as an addendum to the 10-23-00 Technical Report prepared for SCi's operations
located in Suite 150 at 2840 Loker Avenue in Carlsbad, California This report addresses modifications to
warehouse storage conditions and operations [Room 129/Shipping & Receiving] based on applicable
1997/1998 Uniform/California Code requirements and conditions Final plans and completed details for
SCI's revised warehouse storage operations will be determined based on the information provided in this
report \
Seltzer Chemicals Inc is a manufacture of all-natural nutritional health and food supplements The
changes in Room 129 involve increasing rack storage height from 12' to 20' above the finished floor for
Class I-IV Commodities and use of a battery-powered industrial truck [forklift] and battery-charging
operations
The changes in storage conditions and operations and applicable Code requirements and conditions are
addressed in Section 20 Refer to the 10-23-00 Technical Report for existing site, building, site and
operational conditions
Plans associated with changes in Room 129 will be provided separately through Chapo & Hall Architects
Review of such plans for the conditions and requirements addressed herein is outside the scope of this
report v
[NOTE The room names and locations addressed in this report are based on architectural floor plans
dated 11 October 2000 provided by Chapo & Hall Architects ]
This report is the property of Enksen-Rattan Associates Inc and was prepared exclusively for use by Seltzer Chemicals Inc [SCI]
for the operations described in this report Copies of this report retained by SCI shall be utilized only by SCI for occupancy
classification and the Uniform/California Code conditions addressed in this report
This report shall not be used for the purpose of construction for this project or any other project or for any other purpose
I
T Enksen-Rattan Associates Inc Technical Report Addendum - Revised Storage Conditions - Room 129
4719 Palm Avenue, La Mesa CA 91941 Code Requirements & Conditions- 11/19/01 -Page 1 of 6
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
SELTZER CHEMICALS INC.: 2840 Loker Avenue/Suite 150, Carlsbad CA
UNIFORM/CALIFORNIA CODES ANALYSIS - ADDENDUM
2.0 Room 129 - Modifications to Storage Conditions and Operations
Changes to existing storage conditions and operations are described in Table 2 OA on pages 3 & 4 The
major storage change involves rack storage of Class I-IV commodities to 20' above the finished floor,
whereas storage to only 12' above the finished floor was indicated in the 10-23-00 Technical Report The
only operational change involves the use of a battery-powered industrial forklift, including battery-charging
operations, within the storage area
Hazardous materials Control Area conditions for SCI's portion of the building will not impacted by the
change in storage conditions as the materials that will be stored are not regulated through the Codes by
amount [unlimited Exempt Amount] in a fully sprmklered building
Applicable Code conditions and requirements are addressed in Table 2 OB on pages 5 & 6 Existing
conditions within Room 129 will not have to be changed, provided the following conditions are in place and
maintained
* The fire sprinkler design conditions for Room 129 identified in the 10-23-00 Technical Report
are in place
» There is either no shelving in the racks, or only open metal mesh/grated shelving is used in
the racks tn accordance with the conditions indicated in Table 2 OB
* Aisles >/=8' are provided between racks
* High Hazard Commodities packaging materials [plastics] are not stored in racks and are not
stored higher tan 5 5' above the finished floor
TEnksen-Rattan Associates inc Technical Report Addendum - Revised Storage Conditions - Room 129
47-19 Palm Avenue La Mesa CA 91941 Code Requirements & Conditions- 11/19/01 - Page 2 of 6
SELTZER CHEMICALS INC.: 2840 Loker Avenue/Suite 150, Carlsbad CA
UNIFORM/CALIFORNIA CODES ANALYSIS - ADDENDUM
Table 2.0A- Room 129 Storage Conditions & Operations - Modifications
Occupancy SCI Conditions
S-1
Storage
New Conditions/
Changes from
10-23-00
Technical
Report
» Rack Storage/
Class I-IV
Commodities
To 20'above
finished floor -
previously
indicated as
</=l2'
• High Hazard
Commodities/
Plastic
Packaging
Materials
Storage on
shelves & floor
only to </=5 5'
above finished
floor -
previously
indicated as
stored at lowest
rack level
• Raw Materials [Production Materials]
• Raw materials will consist of pre-weighed [pre-batched] and pre-mixed products in
containers received from the SCI's existing Geiger Court warehouse facility
• The raw materials will be delivered to the receiving area'
• Container types in which raw materials will be received may involve any or all of the
following
* Cardboard & fiberboard drums & containers
* Metal drums & containers
* Plastic drums & containers [Group C Plastics]
* Bagged materials in paper & plastic
• Raw materials will be all natural products, consisting primarily of fruit, vegetable and plant
granulated solids, with a texture and consistency similar to that of salt & sugar, with one [1]
liquid raw material [Class IU-B Combustible Liquid - >/=260oC/500oF flashpoint]
» The raw materials [including packaging] will be a Class III Commodity, with most classified
as "nonhazardous" and a few classified as Irritants
• Raw materials will be stored in individual drums [40-100 gallon containers], individual
packages, palletized and non-palletized in the receiving area
• There will be no encapsulated storage conditions
• Storage will involve a combination of rack and floor storage
• Rack Storage
* Single & double-row racks
* Racks will be metal with open shelving, with storage at <A=20' above finished floor
* Racks wiil be seismically braced/anchored
* >/=8' mam aisles
• Floor Storage Floor storage will be at </=6' above finished floor
• Raw materials will be manually transported on drum or pallet carts or hand-earned from the
receiving area to the production areas
• Packaging Materials
• Packaging materials used to package the finished product for shipping will be received and
stored in the receiving area
• Packaging materials will consist of card boa rd/fiberboard cartons/boxes, plastic liners,
cellophane & fiber tape and paper
• Packaging materials will involve a combination of Class 111, IV and V-High Hazard
commodities
• Class l-IV Commodity cartoned and palletized packaging materials will be stored either in
racks or on the floor, with racks and storage conditions as described above for Raw
Materials
• Class V Commodity cartooned and palletized packaging materials will be stored either on
shelves or on the floor at <5 5' above the finished floor These materials will not be stored in
racks
• Pallets
• Pallet storage may involve a combination of metal, wood and nonexpanded polyethylene
pallets
• Idle pallets will be stored on the floor, to a height of <6', with </=4 stacks of pallets per pallet
pile If multiple pallet piles are needed, they will be separated from each other by either a
clear space >/=8' or >/=25' from other storage in the area
• Finished Products
• Finished products may be stored in the shipping area
• Finished products will be nonhazardous or exempted consumer products [UFC/CFC Table
8001 15-B/Footnote 7 and UBC/CFC Table 3-E/Footnote 9}
• Container types in for raw materials will be plastic lined cardboard boxes or fiberboard drums
[Class Ml Commodities]
• Storage conditions will be the same as described Raw Materials
• There will be no encapsulated storage conditions
y Enksen-Rattan Associates Inc
4719 Palm Avenue La Mesa Cft 91941
Technical Report Addendum - Revised Storage Conditions - Room 129
Code Requirements & Conditions - 11/19/01 - Page 3 of 6
SELTZER CHEMICALS INC.: 2840 Loker Avenue/Suite 150, Carlsbad CA
UNIFORM/CALIFORNIA CODES ANALYSIS - ADDENDUM
Table 2.0A - Room 129 Storage Conditions & Operations - Modifications [continued]
Occupancy SCI Conditions
S-1
Forkhft & Battery
Charging
Operations
New Condition -
not indicated in
10-23-00
Technical
Report
*One [1] battery-powered industrial truck [forklift] will be used and parked in Room 129
*One [1] battery-charging unit will be located in Room 129
S-1 - AH
Operations
Existing
Conditions or
No Change to
Existing
Conditions
* Room Configuration
• Room 129 Area </=10,800 sf
• Ceiling Height >/=24'
* Hazardous Materials
• Both raw materials and finished products will be classified as one [1] of the following, with all
such hazard classifications not regulated in the Codes by amounts [unlimited Exempt
Amount]
* Combustible Liquid III-B
* Combustible Liquid III-B & Irritant
* Irritant
* Nonhazardous
• Eriksen-Rattan Associates Inc
4719 Palm Avenue La Mesa CA 91941
Technical Report Addendum - Revised Storage Conditions - Room 129
Code Requirements & Conditions - 11/19/01 -Page 4 of 6
SELTZER CHEMICALS INC.: 2840 Loker Avenue/Suite 150, Carlsbad CA
UNIFORM/CALIFORNIA CODES ANALYSIS - ADDENDUM
Table 2.0B - Code Requirements & Conditions
Requirements & Conditions Code Reference
Draft Curtains Not applicable to SCI conditions for the following reasons
+ High-piled combustible storage for Class l-IV commodities only
» Nonpublic accessible storage area
» Storage area <12.0QO sf
UFC/CFC Table 81-A
Smoke & Heat Venting Not applicable to SCI conditions for the following reasons
» High-piled combustiple storage for Class l-IV commodities only
+ Nonpublic accessible storage area
» Storage area <12,OOJLsj
UFC/CFC Table 81-A
Small Hose Valves & Stations Not applicable to SCI conditions for the following
reasons
» High-piled combustible storage for Class l-IV commodities only
• Nonpublic accessible storage area
• Storage area <12.0QO sf
UFC/CFC Table 81-A
Fire Department Access Doors Not applicable to SCI conditions for the following
reasons
* High-piled combustible storage for Class l-)V commodities only
* Nonpublic accessible storage area
Storage area <12,000 sf
NOTE Existing exterior access door
UFC/CFC Table 81-A
Aisles
» Floor Storage Same as SCI conditions - >/=44"
* Rack Storage Same as SCI conditions -- >/=8'
* Shelf Storage Same as SCI conditions - >/=44"
* Dead-Ends </=20"
UFC/CFC Table 81-A
Racks - Shelving Either no shelving or open metal mesh or grated shelving as follows
+ Metal mesh or grated shelves
* Uniform openings </=6" apart
• Openings^cgmpnsin9^>/=50% of overall shelf area
UFC/CFC 8104 2 3
Racks - Flue Spaces
» Single Row Racks
• Transverse 3"
• Longitudinal Not Required
* Double Row Racks
• Transverse 3" or 6"
• Longitudinal Not Required
UFC/CFC Table 8104 3-A
Fire Sprinkler System Design Same as the conditions indicated in the 10-23-00
Technical Report
• Minimum Ceiling/Roof System Design [Should be same as existing conditions
based on City of Carlsbad Fire Department requirements - design based on flexibility
for changes in existing storage conditions ]
• Density >/=0 45 gpm
• Design Area >/=3,000 sf
• Sprinklers
* Type 286oF/high temperature Standard, large or extra large orifice heads are
acceptable
* Spacing </=100sf
# In-Rack Sprinklers Not required - either no shelving or open mesh shelving as
described above
» Hose Stream Allowance >/=500 gpm
» Water Supply Duration >/=2 hours
UBC/CBC Chapter 9
[904 2]
UBC/CBC Std 9-1 [NFPA
13]
UFC/CFC 1003
UFC/CFC Std 81-1 &81-2
City of Carlsbad Fire
Department Requirements
y Enksen-Rattan Associates Inc
4719 Palm Avenue, La Mesa CA 91941
Technical Report Addendum - Revised Storage Conditions - Room 129
Code Requirements & Conditions - 11/19/01 - Page 5 of 6
SELTZER CHEMICALS INC.: 2840 Loker Avenue/Suite 150, Carlsbad CA
UNIFORM/CALIFORNIA CODES ANALYSIS - ADDENDUM
Table 2.0B - Code Requirements & Conditions [continued]
Requirements & Conditions Code Reference
Powered Industrial Trucks & Battery Charging Operations
* Parking >/=5' from storage
# Repairs Outside building or in a location approved by the Fire Department
» Charging Operations >/=20' from storage
• Ventilation No special ventilation conditions required to maintain flammable vapors @
</=2% from battery charging operations, as explained below
• Number of Battery Cells </=18
• Battery Amp Hours </=840
• Flammable Gas Generation Per Hour
* Total <13 cf flammable gas generation per hour
* Calculation
• Gas Evolution per Hour Per Cell 0 0008 cf/cell/hr [per OSHA]
• Charging Current 5% of amp hour capacity during overcharge period
• Batteries @ 840 Amp Hours <13 cf
* 18 cells
* 18 x 0 0008 x 840 = <13 cf flammable gas generation per hour
• Room/Area Volume >216,000 cf [10,800 sf room x >20' roof/ceiling]
• Air Changes to Maintain <l=2% Flammable Gas Concentration
* Air Changes Required 1 air change every 18 hours - volume of space and general
area ventilation conditions [see Item 6] where trucks will be located will maintain
flammable gas concentration @ <2%
* Calculation
. • [216,000 cf]x[0 02/13 cf per hour] x 60 minutes = 19,440 minutes
• 1 air change every 19.440 minutes = 1 air change every 13 5 days
UFC/CFC 1108
UFC/CFC8001 11 8
OSHA
CFR 1910 178
CFR 1926403
^ Enksen-Rattan Associates Inc
4719 Palm Avenue, La Mesa CA 91941
Technical Report Addendum - Revised Storage Conditions - Room 129
Code Requirements & Conditions- 11/19/01 - Page 6of 6
(D HIO H
h- «« >a w
^> o
o <-1 OI1
8^o
« ¥-.M LLI
m LLI
O W
UJ>LU
h-co
h- -JCO -JD <a Iz