Loading...
HomeMy WebLinkAbout2841 LOKER AVE E; ; CB070976; PermitCity of Carlsbad , ffJJ-• 1635 Faraday Av Carlsbad, CA 92008 05-17-2007 Commercial/Industrial Permit Permit No: CB070976 Building Inspection Request Line (760) 602-2725 Job Address: Permit Type: Parcel No: Valuation: Occupancy Group: Project Title: Applicant: 2841 LOKER AV EAST CBAD Tl Sub Type: 2090831300 Lot#: $66,600.00 Construction Type: SAFTETY SYRINGES STORAGE RACKS Reference #: INDUST 0 NEW· Owner: Status: Applied: Entered By: Plan Approved: Issued: Inspect Area: Plan Check#: ISSUED 04/11/2007 MOP 05/17/2007 05/17/2007 LITTLE SCOTT SINGER IRVING&RUTH LIVING TRUST A 06-30-86 3725 NOBEL CT MIRA LOMA CA 92010 Building Permit Add'I Building Permit Fee Plan Check Add'I Plan Check Fee Plan Check Discount Strong Motion Fee Park Fee LFM Fee Bridge Fee BTD #2 Fee BTD #3 Fee Renewal Fee Add'I Renewal Fee Other Building Fee Pot. Water Con. Fee Meter Size Add'I Pot. Water Con. Fee Reel. Water Con. Fee · $419.51 $0.00 $272.68 $0.00 $0.00 $13.99 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 15250 VENTURA BLVD #1014 SHERMAN OAKS CA 91403 Meter Size Add'I Reel. Water Con. Fee Meter Fee SDCWA Fee CFO Payoff Fee PFF (3105540) PFF ( 4305540) License Tax (3104193) License Tax (4304193) Traffic Impact Fee (3105541) Traffic Impact Fee (4305541) PLUMBING TOTAL ELECTRICAL TOTAL MECHANICAL TOTAL Master Drainage Fee Sewer Fee Redev Parking Fee Additional Fees HMP Fee TOTAL PERMIT FEES Total Fees: $706.18 Total Payments To Date: $706.18 Balance Due: $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 ?? $706.18 $0.00 1:_~~~~~~NS _ATTACHED 5c.tJ..n~e.,,o FINAL APPROVAL Inspector: Date: 9--(/ -0? Clearance: NOTICE: Please take NOTICE that approval of your project includes the 'Imposition' of fees, dedications, reservations, or other exactions hereafter collectively referred to as 'foes/exactions." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which vou have oreviouslv been aiven a NOTICE similar to this ar as to which the statute of limitations has areviouslv otherwise exaired. · , ., PERMiT 'APPLICATION' CITY OF CARLSBAD BUILDING DEPARTMENT 1635 Faraday Ave., Carlsbad CA 92008 Legal Description Lot No. Subdivision Name/Number Name ~3. Name Unit No. Workers' Com·pensatlon Declaration: i hereby affirm under"penaliy of perjury one of tlie fallowing declarat,on·s: FOR OFFICQ'J. ;NEflC::, PLAN cHEcK t-}O-G607oq--:z.<t:t, EST. VAL. {t){o~ U)(:)() ti, \. Plan Ck. Deposit ________ _ Valid;:1ted By \ f Date \.( " \ '-6'27 Phase No. Total # of units # of Bathrooms Fax# D I have and will maintain a certificate of consent to self-insure for work.era' compensation as provided by Section 3700 of the Labor Code, for the performance of the work. ich this permit is issued. I have and will maintain worker's compensation, as required by Section 3700 of the labor Code, for the performance of the work for which this permit is issued. My rk r'scompensatio\t'jl)_su~_nceca'5"_an~licynumberare: ,.,~ Q\·\\• ,1 ~ Insurance C(?mpanv '9KG\jfll Jff ~ a-:(", Policy No'\JJ '::;:':-,L ~J::t'+\\?-'n;S)\~iration Date O O \ 0 '-6 (THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS [$100) OR LESS) D CERTIFICATE OF EXEMPTION: I certify that in the perf work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the WARNING: Failure dollars($100,000), and shall subject an employer to criminal penalties and civll fines lded for in Section 3706 of the Labor Code, interest and atto~ ~ • ______________ ,e;_ ___________________ DATE __ Y_-r ._ ..... --,,,,._.~-+-- I hereby affirm that I am exem from the Contiactor's-Lfcerise Law for the following'reason: D I, as owner of the property or my employees with wages as their sole compensation, will d the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). D I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed purauant to the Contractor's License Law). D I am exempt under Section ________ Business and Professions Code for this reason: 1. I personally plan to provide the major labor and materials for construction of the proposed property improvement. D YES D NO 2. I (have/have not) signed an application for a building permit for the proposed work. 3. I have contracted with the following peraon (firm) to provide the proposed construction (include name/ address I phone number I contractors license number): 4. I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name/ address/ phone number/ /ontractorslicensenumber): -------------------------------------------5. I will provide some of the work, but I have contracted (hired) the following peraons to provide the work indicated (include name I address I phone number/ type of work): PROPERTY OWNER SIGNATURE ___________________________ DATE __________ _ WHITE: File YELLOW: Applicant PINK: Finance , PERMIT APPLICATION , . . . CITY OF CARLSBAD BUILDING DEPARTMENT 1635 Faraday Ave., Carlsbad CA 92008 Page 2 of 2 ;COMPLETETHISSEC110NFORN0N-RESIDEN11AL.BUILDING·PERMITSONLY ·---~---... --.. ---.. . .. ........ , . -. ... -.. Is the apJlllcant or future building occupant r'Ei'quired to submit ·a business· pla:i, acutely hazardous materials registration for or risk inanagemen( and preventionprogram under· Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? D YES D NO Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? D YES D NO Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? D YES D NO IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. ,8. CONSTRUCTION I.ENDING AGEN<;Y . -•m --.. -..... -.. .. .. . ., ---• .. • .. --· · ··.. .. -... -.. • - ·1 iiereby affirm ifuit'there is' a construction lendiniiagency for the peifoimance of.the work for which thii;' permit is i~ued (Sec. 3097(1) Civii Code) .. LENDER'S NAME _________________ _ LENDER'S ADDRESS __________________ _ WHITE: File YELLOW: Applicant PINK: Finance City of Carlsbad Bldg Inspection Request For: 09/10/2007 Permit# CB070976 Inspector Assignment: RB Title: SAFTETY SYRINGES Description: STORAGE RACKS . Type:TI Sub Type: INDUST Job Address: 2841 LOKER AV EAST Suite: Lot: 0 --- Phone: 7608227847 Location: Inspector: ---- OWNER SINGER IRVING&RUTH LIVING TRUST A 06-30-86 Owner: SINGER IRVING&RUTH LIVING TRUST A 06-30-86 Remarks: Total Time: Requested By: TOM Entered By: JANEAN CD Description Act Comments 19 Final Structural il Etr-e.: t74S ·------------ ~ff#'e.,/1 ~ ·---------------------~----- .... ---·-. -~--------·-------------------------------- Comments/Notices/Holds Associated PCRs/CVs Original PC# CV060210 CLOSED 0-EXPIRED BIZ LICENSE; Inspection History Date Description Act lnsp Comments 06/05/2007 14 Frame/Steel/Bolting/Welding CO RB SEE NOTICE 06/04/2007 14 Frame/Steel/Bolting/Welding CA RB EsGil Corporation In <Partnersliip witli government for (}Jui[aing Safety DATE: 5/10/07 J ~T JURISDICTION: City of Carlsbad PLAN CHECK NO.: 070976 SET: II D PLAN REVIEWER D FILE PROJECT ADDRESS: 2841 Loker Ave. East PROJECT NAME: Storage Racks for Safety Syringes D D D D D ~ D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building.codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: Esgil Corporation staff did not advise the applicant that the plan check has been completed. Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Telephone#: Date contactedl· · (by: ) Fax#: Mail Telepho Fax In Person / fl tJv,-i--- REMARKS:\1\ ire Department approval is required.@city fo field verify that the path of travel from the ha~capped parking space to the rack area and the bathrooms serving the rack area comply with all the current disabled access requirements. By: David Yao Enclosures: Esgil Corporation 0 GA D MB D EJ D PC 5/3 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858) 560-1468 + Fax (858) 560-1576 L EsGil Corporation In (J!artners.i.ip wit.i. qovernment for <Bui[aing Safety DATE: 4/24/07 CJ PPLICANT RIS. JURISDICTION: City of Carlsbad PLAN CHECK NO.: 070976 SET:I CJ PLAN REVIEWER CJ FILE PROJECT ADDRESS: 2841 Loker Ave. East PROJECT NAME: Storage Racks for Safety Syringes D D D D D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: Scott Little 3725 Nobel Ct. Mira Loma, CA 91752 Esgil Corporation staff did not advise the applicant that the plan check has been completed. Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: S~o Little Date contacted: Lf6 /'.'d'I (by: fbi' Mail TelephonJ ax .A"Person REMARKS: By: David Yao Esgil Corporation D GA D MB D EJ D PC Telephone#: 951-727-0477 Fax #: f J1-7a1.,,. ()l/ lflf Enclosures: 4/16 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858) 560-1468 + Fax (858) 560-1576 l City of Carlsbad 070976 4/24/07 · GENERAL PLAN CORRECTION LIST JURISDICTION: City of Carlsbad PROJECT ADDRESS: 2841 Loker Ave. East DATE PLAN RECEIVED BY ESGIL CORPORATION: 4/16 REVIEWED BY: David Yao FOREWORD (PLEASE READ): PLAN CHECK NO.: 070976 DATE REVIEW COMPLETED: 4/24/07 This plan review is limited to the technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and disabled access. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department or other departments. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3, 1997 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. • To facilitate rechecking, please identify, next to each item, the sheet of the plans upon which each correction on this sheet has been made and return this sheet with the revised plans. • Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located on the plans. Have changes been made not resulting from this list? D Yes D No City of Carlsbad 070976 4/24/07 Please make all corrections, as requested in the correction list. Submit three new complete sets of plans for commercial/industrial projects (two sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. 1. Provide a rack layout plan showing the location of all racks.(a. The new 3 deep racks at bottom of the sheet did not specify what type rack are these? Please add the information on the plan. b. The elevation did not show which one is european pallet. (at bottom of the sheet?) 2. Only the storage racks are included in this plan review 3. Provide a statement on the Title Sheet of the plans that this project shall comply with Title 24. 4. Provide a note on the plans indicating if any hazardous materials will be stored and/or used within the building which exceed the quantities listed in UBC Tables 3-D and 3-E. 5. The tenant space and new and/or existing facilities serving the remodeled area must be accessible to and functional for the physically disabled. Show a path of travel from the handicapped parking space to the rack area and the bathrooms serving the rack area comply with all the current disabled access requirements. Title 24, Part 2. 6. Obtain Fire Department approval for groups F, Mand S occupancy storage per UBC Sections 306.8, 309.8 and 311.8. 7. Indicate the clearance from the new racks to the existing building walls and building columns. 8. Provide forklift protection per Section 2222.5.(or check the exception) 9. Sheet 21.2 of the calculation shows the type D & G exterior requires 3.5x2.75 beam. Sheet SCE1 of 1 of the plan shows C3x3.5 beam. Conservative? 10. Sheet 31 and 32 of the calculation shows the base plate for the European rack is 8x8x.375. The plan shows 8x5x.375 plate only for this project. Please check. City of Carlsbad 070976 4/24/07 . Recheck the "pallet" racks as follows: 11. Recheck all connections on sheet SCE1 as follows: a) The rivet bearing capacity is only dtFu = 0.406(0.0747)65 = 2 kips. b) Provide calculations for all beam to bracket weld capacities per Section 2330 (allowable weld stress is the member thickness times 26 ksi times 1.33, or the weld stress, whichever is lower). c) Check the bracket maximum weak axis moment. 12. Provide calculations for the column weak axis bending plus axial for transverse seismic loading. The axial load is the maximum compression load at the base from vertical plus seismic overturning. The column moment will probably be maximum for the lateral load from the base plate to the first diagonal brace (not only to the first horizontal member). 13. The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact David Yao at Esgil Corporation. Thank you. €, SafetySyringes, lnC: Safety Syringes, Inc. 2875 Loker Avelllle East. Carlsbad CA. 92010 voice.760.918.9908 fax. 760.918.0565 April 11, 2007 To: City of Carlsbad 1635 Faraday Ave. Carlsbad, CA 92008 Re: Letter of intent-High piled combustible storage information The facility will be used for storage of plastic ·syringe assembly material in cardboard boxes, including plastic casings, metal springs, and seals. The total percentage of plastics will be approx. 60% stored in cardboard boxes non-encapsulated, which will be stored with the remainder of material in racks on non-encapsulated wooden pallets. Thank you for your assistance. PLANNING/ENGINEERING APPROVALS PERMIT NUMBER C. i3 07-97/.o DATE t..i-1,-0, ADDRESS a '841 Loke"Y" Gweoue.. RESIDENTIAL (r'ENANT IMPROVEM~~ RESIDENTIAL ADDITION MINOR PLAZA CAMINO REAL (<$10,000.00) CARLSBAD COMPANY STORES POOL/ SPA VILLAGE FAIRE . . . . RETAINING WALL COMPLETE OFFICE BUILDING OTHER. _________________ _ PLANNER_.'r ___ rn ........ n=--J..Jl.A=---6---DATE LJ-17-07 ENGINEER ________ _ DATE __ _ ... Carlsbad ;F'ire. Department I '> I I BUILDING DEPT. COPY Plan Review Requirements Category: TI , INDUST Reviewed by: __ 4 __ 4_, ~-Date of Report: 05-15-2007 Naine: Address: Permit#: CB070976 Job Naine: SAFTETY SYRINGES Job Address: 2841 LOKER AV EAST CBAD ~M~=~~e.m:¥fl1i=llllve submitted for review is incomplete. At this time, this office cannot adequately conduct a review to determine compliance with the applicable codes and/or standards. Please review carefully all comments attached. Please resubmit the necessary plans and/or specifications, with changes "clouded", to this office for review and approval. Conditions: Cond: CON000203 8 Eil T@:Pfvffl'f'_f'Pfovide an automatic fire sprinkler system. Said system shall be installed in th_e proposed rack system. Cond: CON0002039 [NOT MET] To determine the acceptability of the proposed use CFD shall require the owner or the person in possession or control of the building or premises to provide, without charge to the jurisdiction, a technical opinion and report. The opinion and report shall be prepared by a qualified engineer, specialist, laboratory or fire-safety specialty organization acceptable to the chief and the owner and shall analyze the fire-safety properties of the design, operation or use of the building or premises and thereon, to recommend necessary changes thereon, to recommend necessary changes. Cond: BP022 ~fB,~at~ith Articles 1 and 81 of the California Fire Code for high-piled combustible storage. High piled combustible storage is storage of combustible materials of more than 500 square feet where materials are stored over 12 feet in height from the floor to the top of the storage. For certain high-hazard commodities, storage height over 6 feet ~vill require a permit from the fire department. Entry: 04/24/2007 By: GR Cond: CON000207 4 [MET] Action: CO Entry: 05/15/2007 By: GR Action: AP ,, ' . *if.~ THIS PROJECT HAS BEEN REVIEWED AND APPROVED FOR THE PURPOSES OF ISSUANCE OF BUILDING 'PERMIT. ' THIS APPROVAL IS SUBJECT TO FIELD INSPECTION AND REQUIRED TEST, NOTATIONS HEREON, CONDITIONS IN CORRESPONDENCE AND CONFORMANCE WITH ALL APPLICABLE REGULATIONS. THIS APPROVAL SHALL NOT BE HELD TO PERMIT OR APPROVE THE VIOLATION OF ANY LAW. Entry: 05/14/2007 By: GR Action: AP ,_ . C~~lsµad jfire. Department Plan Review Requirements Category: TI, INDUST Date of Report: 04-24-2007 Name: Address: Permit#: CB070976 Job Name: SAFTETY SYRINGES Job Address: 2841 LOKER AV EAST CBAD BUILDING DEPT • COPY Reviewed by: ___,__I/_~_ INCOMPLETE The item you have submitted for review is incomplete. At this time, this office cannot adequately conduct a review to determine compliance with the applicable codes and/or standards. Please review carefully all comments attached. Please resubmit the necessary plans and/or specifications, with changes "clouded", to this office for review and approval. Conditions: Cond: CON0002038 [NOT MET] Provide an automatic fire sprinkler system. Said system shall be installed in the proposed rack system. Cond: CON0002039 [NO:r MET] To determine the acceptability of the proposed use CPD shall require the owner or the person in possession or control of the building or premises to provide, without charge to the jurisdiction, a technical opinion and report. The opinion and report shall be prepared by a qualified engineer, specialist, laboratory or fire-safety specialty organization acceptable to the chief and the owner and shall analyze the fire-safety properties of the design, operation or use of the building or premises and thereon, to recommend necessary changes thereon, to recommend necessary changes. Cond: BP022 [NOT MET] Comply with Articles 1 and 81 of the California Fire Code for high-piled combustible storage. High piled combustible storage is storage of combustible materials of more than 500 square feet where materials are stored over 12 feet in height from the floor to the top of the storage. For certain high-hazard commodities, storage height over 6 feet will require a permit from the fire department. Entry: 04/24/2007 By: GR Action: CO· ,. ' s~~t~ra~ . ' l, ts ngineering 1729 S. Douglass RD, Ste B Anaheim, CA 92806 Tel: 714.456.0056 Fax: 714A56.0066 Project: SAFETY SYRINGES Project#: G-032807-2 Date: 04/27/07 STRUCTURAL REQUIREMENTS: 2841 LOKER AVE. EAST CARLSBAD,CA.92010 Project #: 70976 Plan Review Responses 8. PLEASE SEE REVISED CALCULATIONS WHERE COLUMNS HAVE BEEN FOR ADEQUACY WITHOUT THE USE OF POST PROTECTORS PER SECTION 2222.5 OF THE CBC. SEE CALC. PAGE 7.2. 9. PLEASE SEE REVISED CALCULATION PAGE 21.2 WHERE THE BEAM HAS BEEN CORRECTED TO THE STRUCTURAL C3 X 3.5# BEAM AS REQUIRED. 10. PLEASE NOTE THAT THE EUROPEAN EXTERIOR BASE PLATE SHOULD BE AN 811 x 5" BASE AS SHOWN ON THE DETAILS, PLEASE SEE REVISED CALCULATION PAGES 31 & 32 FOR CORRECTED BASE PLATE. 11. PLEASE Sl;E REVISED CONNECTION ANALYSIS FOR REVISION OF ANALYSIS AS REQUIRED. SEE CALC. PAGE 9. 12. PLEASE SEE REVISED CALCULATIONS WHERE COLUMN HAS BEEN CHECKED FOR WEAK AXIS BENDING PLUS AXIAL FOR TRANSVERSE SEISMIC LOADING. SEE CALC. PAGE 7.3. PLEASE FEEL FREE TO CALL WITH ANY QUESTIONS YOU MAY HAVE REGARDING THE ABOVE MATTERS. ., tructural I I ng1neer1ng 1200 N. Jefferson St., Suite F Anaheim, CA 92807 Tel: 714.632.7330 Fax: 714.632.7763 e-mail: mail@sceinc.net Prc?)ect Name : SAFETY SYRINGES Prqject Number: G-032807-2 Date: 04/27/07 Street Address : 2841 LOKER AVE. EAST City/State : CARLSBAD, CA. 92010 Scope of Work: STOR,A,GE RACKS APR 2 7 2001 , Structural · Concepts ~./J Engineering ~ 1729 -S. Douglass l<d. Ste B Anaheim. CA .92806 Tel: 714.456.0056 Fax: 714.456.0066 By: BOB Project: SAFETY SYl<INGES. INC. TABLE OF CONTENTS 1itle Page .. .............................................................................................................. 1 Table of Contents..................................................................................................... 2 Design Data and Definition of Components ............................................................ 3 Critical Configuration .................................................. ............................................ 4 Seismic Loads ............................................................ ·............................................. 5 to 6 Column.................................................................................................................... 7 Beam and Connector ............................................................................................... 8 to 9 Bracing.................................................................................................................... 10 Anchors ......................................................................... ·---······--················· Base Plate ............................................................................................................... . Slab on Grade ......................................................................................................... . Pushback Rack Analysis ......................................................................................... . 11 12 13 14 to '3 "2..- TYPE A SR-SAFETY SYRINGES Page Z.,..-of ~ 1-- Project i:t: G-032807-2 4/2/2007 Structural · C~nc~pts ~ Engineering ·-1729 S. Douglass Rd, Ste B Anaheim, CA 92806 Tel: 714.456.0056 Fax: 714.456.0066 By: BOB Project: SAFETY SYRINGES, INC. Project l:I: G-0321307-2 Design Data 1) The analyses conforms to the requirements of the 2001 CBC, utilizing division X of chapter 22 and section 1630.2 2) Transverse braced frame steel conforms to ASTM A570, Gr.SO, with minimum strength, Fy=S0 ksi Longitudinal frame beam and connector steel conforms to ASTM A570, Gr.SO, with minimum yield, Fy=S0 ksi All other steel conforms to ASTM A36, Gr. 36 with minimum yield, Fy= 36 ksi 3) Anchor bolts shall be provided by installer per ICBO reference on plans and calculations herein. Installer must provide any special inspection as. called out on plans or calculations, or as required by the ICBO report indicated herein. 4) All welds shall conform to AWS procedures, utilizing E70xx electrodes or similar. All such welds shal! be performed in shop, with no field welding allowed other than those supervised by a licensed deputy inspector. 5) The slab on grade is 5" thick with minimum 2000 psi compressive strength. Soil bearing capacity is 1000 psf. Definition of Comnonents t= 1--}-- Frame Height ~= A ;-4 Beam Product . ~ .. - Beam Length Front View: Down Aisle (Longitudinal) Frame Column =~ Beam to Column Connector Base Plate and Anchors ~::~ Section A: Cross Aisle (Transverse ) Frame Horizontal Brace Diagonal Brace The components herein are designed within the guidelines of the 2001 CBC and with due regard to established industry standards set forth by the Rack Manufacturer's Institute. Building official .must approve final submitted design. TYPE A SR-SAFETY SYRINGES "'1/2/2007 S-i-ructural ·C;nc~p-ts ~ Engineering . -~ 1729 S. Douglass Rd. Ste B Anaheim. CA 92B06 Tel: 714.456.0056 Fax: 714.456.0066 By: BOB Project: SAFETY SYRINGES. INC. Project :ii: G-032807-2 Configuration & Summary: TYPE A SINGLE ROW T 96" 180" t 84" J ~ ' Seismic Zone # Bm Lvls 4(Na=1.0) 2 Tlong=0.27 sec/ Tshort=0.15 sec Component Column Fy=50 ksi Column Backer None Beam Fy=50 ksi Beam Connector · Fy=50.ksi Brace-Horizontal Fy=50 ksi Brace-Diagonal Fy=50ksi Base Plate Fy=36 ksi Anchor 2 per Base Slab Level I Load ~er Level BeamSpcg 1 2,000 lb 84.0in 2 96.0in Notes TYPE A SR-SAFETY SYRINGES 180" 108" .f'-42" -,.j Frame Depth!Frame Height! # Diagonals Beam Length I Frame Type 42in I 180.0 in I 3 108in I Single Row Description STRESS LMT LM20/3x3xl 4ga P=2075 lb, M=l2231 in-lb 0.52-0K None None N/A LMT LBF404/4"deepx2.75"x0.075" Lu=108in I capacity:43371b/pr 0.46-0K Lvl 1: 3 pin OK I Mconn=10913 in-lb I Mcap=l6922 in-lb 0.64-0K lMf 1-1/2x1-1/4x14ga 0.14-0K lMf 1-1/2x1-1/4x14ga 0.45-0K 8x5x0.375 I Fixity= 0 in-lb 0.19-0K 0.5" x 3.375" fmbed RAMSET REDHEAD 1RUBOL T ICBO ESR 2251 No Inspection (T =955 lb) 0.07-0K 5" thk x 2000 psi slab. 1000 psf Soil Bearing Pressure Brace 56.0 in 56.0 in 56.0in Total: I Story Force I Story Force Transv Longit. 2361b 961b 5051b 2061b 741 lb 3021b Paqe c( of ~ 2.- Column f Axrat 2,075 lb 1,038 lb 0.29-0K Column I Conn. Beam Moment Moment Connector 12,231 "# 10,913 "# 3 pin OK 4,942 "# 4,798 "# 3pin OK 4/2/2007 Structural ·c;nc~pts ~-/J Engineering ·--~ 1729 S. Douglass Rd, Ste B Anaheim, CA 92806 Tel: 714.456.0056 Fax: 714.456.0066 By: BOB Project: SAFETY SYRINGES. INC. Seismic Forces Configuration: TYPE A SINGLE ROW Lateral analysis is performed with regard to sections 2228.5.2 and 1630.2 of the 2001 CBC Base shear is highest of: 1) Cv*I*W/(R*T*1.4) (EQ 304) <= 2.5*(a*I*W/(R*1.4) (Eq 30-5) 2) 0.ll*ca*I*W/1.4 (Eq 30·6) 3) 0.8*Z*Nv*I*W/(R*1.4) (Eq 30-7) 4) 1.5%*(DL+LL) (Sec 2228.3.2) Transverse {Cross Aisle) Seismic Load T = Ct*{H)°-75 = VEQ 30-4= 0.693 VEQ3Q-6= 0.035 . Base Shear Coeff= 0.1786 Level 1 2 LL 2,000 lb 2,000 lb Longitudinal (Downaisle) Seismic Load T=(Ct)*hA0.75= 0.27 sec VEQ 30-4= 0.302 VEQ 30-6= 0.035 Base Shear Coeff= 0.1403 Level 1 2 LL 2,000 lb 2,000 lb TYPE A SR.-SAFETY SYRINGES 0.15 sec Ct-transv= 0.020 <= VEQ3o-s= 0.1786 V222s.3.2.= 0.015 VEQ3o-7= 0.033 n-transv= 1 Vtransv= Base Shear Coeff * (ZDL + :ELL/n-transv) = 0.1786 * (150 lb + 4000 lb/1) = 741fb LL/{n-transv) DL 2,000 lb 75 lb 2,000 lb 75 lb 4,000 lb 1501b hi 84in 180in W=4150lb Ct-long= 0.035 <= VEQ3o-s= 0.1403 V222s.J.2.= 0.015 wi*hi 174,300 373,500 547,800 Vlong= Base Shear Coeff * (:EDL + :ELL/n-long) = 0.1403 * (150 lb + 4000 lb/2) LL/(n-long 1,000 lb 1,000 lb 2000 lb = 3021b DL 75lb 751b 1501b hi 84in 180in W=2150 lb Page 7.--of j i,. wi*hi 90,300 193,500 283800 Project j:;: G-032807-2 I= 1.0 Seismic Zone 4, Z= 0.4 ca= o.44 Na= 1.0 Cv= 0.64 Nv= 1.0 (Transverse) R= 4.4 R Fi*hi 235.8 lb 505.2 lb 19,807-# 90,936-# 741 lb (Longitudinal ) R= 5.6 n-long= 2 R 96.1 lb 205.9 lb 3021b 1=110,743 4/2/2007 Structural ·c~nc~pts ~/J Engineering -~ 1729 S. Douglass Rd, Ste B Anaheim, CA .92806 Tel: 714.456.0056 Fax: 714.456.0066 By: BOB Project: SAFETY SYRINGES, INC. Downaisle Seismic Loads Configuration: 1YPE A SINGLE ROW Determine the story moments by applying portal analysis. The base plate is assumed to provide no fixity. Seismic Story Forces Vlong= 302 lb Typical fume macle Ttibutaryatea oftwocolumns of,ackti-amc X,.-----Vcol=Vlong/2= 151 lb Fl= 96Ib. F2= 206 lb F3= 0 lb ~ ~ ~ f ~ Seismic Story Moments Mbase-max= O in-lb <=== Default capacity Mbase-v= (Vcol*hleff)/2 .... ________ ,,, Conceptual System h1-eff= h1 -beam clip height/2 = 81 in = 6,116 in-lb <=== Moment going to base Mbase-eff= Minimum of Mbase-max and Mbase-v = O in-lb M 1-1= [Vcol * h1eff]-Mbase-eff = (151 lb * 81 in)-0 in-lJ:> = 12,231 in-lb M 2-2= [Vcol-(F1)/2] * h2 = [151 lb -103 lb]*96 in/2 = 4,942 in-lb Project~: G-032807-2 h2 h1 h1eff 11 Mseis= (Mupper+MIOWer)/2 Mseis(l-1)= (12231 in-lb+ 4942 in-lb)/2 = 8,586 in-lb Mseis(2-2)= (4942 in-lb+ o in-lb)/2 = 2,471 in-lb Beam to Column Elevation LEVEL 1 2 hi 8410 96in TYPE A SR-SAFETY SYRINGES Axial Load 2,075 lb 1,038 lb Summary of Forces Column Moment Mseismic Mend-fixity Mconn Beam Connector 12,231 in-lb 8,586 in-lb 2,327 in-lb 10,913 in-lb 3 pin OK 4,942 in-lb 2,471 in-lb 2,327 in-lb 4,798 in-lb 3pin OK Page (r of 3 1,..--4/2/2007 Structural ·c;nc~pts ~..;j Engineering -~ 1729 S. Douglass Rd, Ste B Anaheim, CA 92806 Tel: 714.456.0056 Fax: 714.456.0066 By: BOB Project: SAFETY SYRINGES, INC. Project#: G-O328O7-2 Column Configuration: TYPE A SINGLE ROW Conforms to the requirements of Chapter CS of the 1996 AISI Cold Formed Steel Design Manual for combined bending and axial loads. Section Properties Section: lMT LM20/3x3x14ga Kx= 1.2 y----+----y 3,000 in Aeff = 0.643 inA 2 Ix= 1.130 inA4 Sx = 0.753 inA3 rx = 1.326 in .Qf= 1.67 E= 29,500 ksi Iy = 0.749 inA4 Sy = 0.493 inA 3 ry = 1.080 in Fy= 50 ksi Cmx= 0.85 Lx = 84.0 in Ky= 1.0 Ly= 56.0 in Cb= 1.0 l 0.075 in _J_ ~0.75in Loads Axial=P= 2,075 lb Moment=Mx= 12,231 in-lb (Column stresses @ Level 1) Axial Analysis Kxl.x/rx = 1.2*84"/1.326" = 76.0 Fe= nA2E/(Kl/r)maxA2 = 50.4ksi Pn= Aeff*Fn = 24,1741b P/Pa= 0.16 Bending Analysis > 0.15 KyLy/ry = 1 *56"/1.08" = 51.9 Fy/2= 25.0 ksi Qc= 1.92 Check: P/Pa + (Cmx*Mx)/(Max*µx) !> 1.33 P/Pao + Mx/Max !> 1.33 Pno= Ae*Fy Pao= Pno/Qc Fe> Fy/2 Fn= Fy(l-Fy/4Fe) = 50 ksi*[l-50 ksi/(4*50.4 ksi)] = 37.6ksi Pa= Pn/Qc = 24174 lb/1.92 = 12,590 lb Myie!d=My= Sx*Fy = 0,643 jnA2 *50000 psi = 32,150 lb = 32150lb/1.92 = 16,745 lb = 0.753 inA3 * 50000 psi = 37,650 in-lb Max= My/.Qf = 37650 in-lb/1.67 = 22,545 in-lb µx= {1/[1-(Qc*P/Pcr)]}A-1 = {1/[1-(1.92*2075 lb/32380 lb)J}A-1 = 0.88 Combined Stresses Per= nA2EI/(KL)maxA2 = nA2*29500 ksi/(1.2*84 in)A2 = 32,380 lb (2075 lb/12590 lb)+ (0.85*12231 in-lb)/(22545 in-lb*0.88) = (2075 lb/16745 lb)+ {12231 in-lb/22545 in-lb)= 0.69 0.67 < 1.33, OK < 1.33, OK lYPE A SR-SAFElY SYRINGES (EQ CS-1) (EQ CS-2) 4/2)2007 St~tu.ra~ , . VonEts ~--4 ngineering • ~ 1729 S. Douglass Rd, Ste B Anaheim, CA 92806 Tel: 714.456.0056 Fax: 714.456.0066 By: BOBS. Project: SAFETY SYRINGES INC. Project#: G-032807-2 Column-Exposed Post Check Conforms to the requirements of Chapter CS of the 1996 AISI Cold Formed Steel Design Manual for combined bending and axial loads. Check post protector requirement of 2001 CBC Sec 2222.5 Section Properties Loads Section: 3x3x14 ga Aeff = 0.643 inA2 Ix= 1.130 inA4 Sx = 0.753 inA3 rx= 1.326 in Qf= 1.67 E= 29,500 ksi Axial=P= 2,.075 lb Axial Analysis Kxlx/rx = 1.7*84"/1.326" = 107.7 Fe= n"'2E/(KL/r)max"2 = 25.lksi Pn= Aeff*Fn = 16,142 lb P/Pa= 0.25 Bending Analysis Iy = 0.749 in"'4 Sy= 0.493 in"'3 ry= 1.080 in Fy= 50 ksi Cmx= 0.85 width= 3.000 in depthl= 3.000 in thickl= 0.075 in Moment=Mx= 0 in-lb > 0.15 Kyly/ry = 1*56"/1.08" = 51.9 Fy/2= 25.0 ksi Qc= 1.92 Check: P/Pa + (Cmx*Mx)/(Max*µx) :$ 1.33 P/Pao + Mx/Max $ 1.33 Pno= Ae*Fy Pao= Pno/Qc = 0.643 in"2 *50000 psi = 32,150 lb = 321501b/l.92 = 16,745 lb Kx = 1.7 Lx= 84.0 in Ky= 1.0 Ly= 56.0 in Cb= 1.0 Fe> Fy/2 Fn= Fy(1-Fy/4Fe) = 50 ksi*[l-50 ksi/(4*25.1 ksi)] = 25.1 ksi Pa= Pn/Qc = 16142 lb/1.92 = 8,407 lb Myield=My= Sx*Fy = 0.753 in"3 * 50000 psi = 37,650 in-lb Max= My/Qf Per= n"2EI/(KL)max"'2 = 37650 in-lb/1.67 = 22,545 in-lb µx= {1/[1-(Qc*P/Pcr)]}"-1 = {1/[1-(1.92*2075 lb/16134 lb)]}"-1 = 0.75 -Combined Stresses = n"2*29500 ksi/(1.7*84 in)"'2 = 16,134 lb (2075 lb/8407 lb) + (0.85*0 in-lb)/(22545 in-lb*0.75) = (2075 lbf16745 lb) + (0 in-lb/22545 in-lb) = 0.25 0.12 < 50%, OK per sec. 2222.5 No Post Protector Required <1ge ... 7 o . l_ St~tu~al_ . . Vonj:;ts -~ ngineering ~ 1725 S. Douglass Rd, Ste D Anaheim, CA 92806 Tel: 714.456.0056 Fax: 714.456.0066 By: BOBS. Project: SAFETY SYRINGES Project#: G.{)32807-2 umn Conforms to the requirements of Chapter CS of the 1996 AISI Cold Formed Steel Design Manual for combined bending and axial loads. Section Properties Loads Section: 3x3x14 ga Aeff = 0.643 in"2 Ix= 1.130 in"4 Sx = 0.753 in"3 rx = 1.326 in Qf= 1.67 E= 29,500 ksi Cb= 1.0 Kx = 1.7 Ky= 1.0 Movt= 127,354 in-lb Frame Depth= 42 in Seismic Axial=Pv= Movt/d = 3,032 lb -Axial Analysis KxLx/rx = 1.7*84"/1.326" = 107.7 Fe= n"2E/(KL/r)maxA2 = 25.lksi Pn= Aeff*Fn = 16,1421b P/Pa= 0.61 Bending Analysis > 0.15 Iy = 0.749 in,,..4 Sy = 0.493 in" 3 ry = 1.080 in Fy= 55 ksi Cmx= 0.85 width= 3.000 in depthl= 3.000 in thickl= 0.090 in Lx= 84.0 in Ly= 56.0 in t--3.0" --t T 3.0" 14ga l t---t--0.75" V -.. Ttansvetse Elevation Static Axial=Ps= 2,075 lb Ptotal=P= 5,107 fb V= 741 lb h= 6 in Kyly/ry = 1*56"/1.08" = 51.9 Fy/2= 27.5 ksi Qc= 1.92 Moment=My= V*h Fe< Fy/2 Fn= Fe = 4,446 in-lb = nA2E/(KL/r)maxA2 = 25.1 ksi Pa= Pn/Qc = 16142 lb/l.92 = 8,4071b Check: P/Pa + (Cmy*My)/(May*µy) :f 1.33 P/Pao + My/May :f 1.33 Pno= Ae*Fy Pao= Pno/Qc Myield=My= Sy*Fy h = 0.643 inA2 *55000 psi = 35,365 lb = 353651b/1.92 = 18,419 lb = 0.493 jnA3 * 55000 psi = 27,115 in-lb May= My/Qf = 27115 in-lb/1.67 = 16,237 in-lb µx= {1/[1-(Qc*P/Pcr)]},,..-1 = {1/[1-(1.92*5107 lb/16134 lb)J}A-1 = 0.39 Combined Stresses Per= n"2EI/(KL)maxA2 = nA2*29500 ksi/(1.7*84 in)A2 = 16,134 lb (5107 lb/8407 lb)+ (0.85*4446 in-lb)/(16237 in-lb*0.39) = (5107 lb/18419 lb)+ (4446 in-lb/16237 in-lb)= 1.20 0.55 < 1.33, OK < 1.33, OK Page 7,, of -~ '2- (EQ C5-1) (EQ C5-2) Structural ·Concepts· ~;j Engineering -~ 1729 S. Douglass Rd, Ste B Anaheim, CA .92806 Tel: 714.456.0056 Fax: 714.456.0066 By. BOB Prqject: SAFETY SY!<INGES, INC. Project l:i: G-032807-2 Beam Configuration: TYPE A SINGLE ROW The beam to column connection is assumed to provide partial end fixity for the beam frame. The end moment calculated herein is added to the lateral force force portal moment when analyzing the connection capacity. Designed per section 2228 of the 2001 CBC The impact ioad on the beam is addressed by including the impact Factor r.a" in the determination of the beam center bending stress. Section Properties Beam Member= LMf LBF404/4"deepx2.75"x0.075" Beam at Level= 1 Beam Type= Formed Ix= 2.050 inA4 Sx= 0.948 inA3 Length=L= 108.0 in LU= 108.0 in Beam Weight= 4.0 lb/ft Thickness= 0.075 in Beam Shape= Step t--2.750 inl . tt.875in 1-T ,.,oo,, 4.000in -1- Impact Factor (a)=f1-(25%/2)]= 0.875 l 0.075in ~ Loads % End Rxity= 25 % 0 = 0.25 Mcenter= B*(wL A2f8) = 0.832*(wL A2/8) Mends= 0*Mmax(fixed ends) = (wL A2/12)*0.25 = 0.0208*WL A2 Fb= 0.6 * Fy = 30,000 psi Coeff B= 0.104/0.125 = 0.832 Mcenter= Mcenter(simple ends) -0*Mcenter(fixed ends) = wL "2/8 -(0.25 * wL "2/12) = wLA2/8 -wLA2/48 = 0.104*wLA2 Fy= 50,000 psi Fb-eff= 30,000 psi Live Load/Pair= 2,000 lb Dead Load/Pair= ( 4 lb/ft) * 2 * 108 in/12 = 721b Dist Load=w= 9.6 lb/in Bendin Mcenter= 0.104 * wL"2 = 11,636 in-lb M= 11,636 in-lb fb= (M/Sx)/a = 14,028 psi Bending Capcity= 4,337.lb/pair Deflection Defl-allow=L/ 180 Mends= 0.0208*wL"2 = 2,327 in-lb fb/Fb= 14028 psi/30000 psi 0.47 <= 1.0, OK <=== Critical Defl= B * [5wL A4/(384*E*Ix)J = 0,600 in = [5*9.6 lb/in*(108 in)"4/(384*29.5x10"6 psi * 2.05 in"4)J*0.832 0.234in Deflection Capacity= 5,241 lb/Pair Allowable load per beam pair= 4,337 lb TYPE A SR-SAFETY SYRINGES Page Y of ?:, ')...- <= 0.6 in, OK 4/2/2007 Structural c:; . ~ ts ' ' ~-ngineering ~ ~729 S. Douglass Rd. Ste B Anaheim, CA 92B06 Tel: 714.456.0056 Fax: 714.456.0066 By: BOB Project: SAFETY SYRINGES, INC. 3 Pin Beam to Column Connection TYPE A SINGLE ROW Mconn max= 10,913 in-lb Load at level 1 Connector Type= 3 Pin Shear Capacity of Pin Pin Diam= 0.44 in · Fy= 50,000 psi Ashear= (0.438 in)"2 * Pi/4 = 0.1507 in"2 Pshear= 0.4 * fy * Ashear = 0.4 * 50000 psi* 0.1507in"2 = 3,014 fb Bearing Capacity of Pin Per thei996 A1SI Cold Formed steel Manual, Sec E3.3: tcol= 0.075 in Omega= 2.22 Fu= 65,000 psi a= 2.22 Pbealing= alpha * Fu * diam * tcol/Omega = 2.22 * 65000 psi * 0.438 in * 0.075 in/2.22 = 2,135 lb < 3014 lb Moment capacity of Bracket Edge Distance=E= 1.00 in Pin Spacing= 2.0 in C= Pl+P2+P3 tclip= 0.18 in = Pl +Pl *(2.5"/4.5")+Pl *(0.5"/4.5") = 1.667 * Pl Mcap= Sclip * Fbending = 0.127 in"3 * 0.66 * Fy = 4,191 in-lb Pclip= Mcap/(1.667 * d) C*d= Mcap = 1.667 = 4191 in-lb/(1.667 * 0.5 in) = 5,028 lb Thus, Pl= 2,135 lb Mconn-allow= [Pl *4.5"+P1 *(2.5"/4.5")*2.5"+Pl *(0.5" /4.5")*0.5"]*1.33 = 2135 LB*[4.5"+(2.5"/4.5")*2.5"+ (0.5"/4.5")*0.5"]*1.33 = 16,922 in-lb > Mconn max, OK TYPE A SR-SAFETY SYRINGES Page 1, of ) 2--- Fy= 50,000 psi Sclip= 0.127 in"3 d= E/2 = 0.50 in Project i=I': G-032807-2 4/2/2007 Structural ·ca.nc~pts ~/J Engineering --~ 1729 S. Douglass Rd, Ste B Anaheim, CA 92806 Tef: 714.456.0056 Fax: 714.456.0066 By: BOB Pr,aject: SAFETY SYRINGES. INC. Transverse Brace Configuration: lYPE A SINGLE ROW Section Properties Diagonal Member= LMT 1-1/2x1-1/4x14ga Area= 0.278 inA 2 r min= 0.405 in Horizontal Member= LMT 1-1/2x1-1/4x14ga r-1.sooin4 Fy= 50,000 psi K= 1.0 Qc= 1.92 ··RT 0.075 in ro in Area= 0.278 inA2 r min= 0.405 in Fy= 50,000 psi K= 1.0 Frame Dimensions Diagonal Member Bottom Panel Height=H= 56.0 in Frame Depth=D= 42.0 in Column Width=B= 3.0 in V=Vtransv= 741 Jb Ldiag= [(D-B*2)A2 + (H-6n)A2]A1/2 = 61.6 in Pmax= V*(ldiag/D) = 1,087 lb Pn= AREA*Fn =-0.278 inA2 * 12585 psi = 3,499 lb Pallow= Pnf .Q = 3499 lb /1.92 = 1,8221b aear Depth=D-B*2= 36.o in XBrace= NO SINCE Fe<Fy/2, (kl/r)= (k * Ldiag)/r min = (1 x 61.6 in /0.405 in ) = 152.1 in Fe= piA2*E/(kf/r)A2 = 12,585 psi Fn= Fe = 12,585 psi Check End Weld Lweld= 2.5 in Fu= 65 ksi tmin= 0.075 in Project #: G-032807-2 -, l=======l l Typical Panel Configuration Weld capacity= 0.75 * tmin * L * Fu * 1.33/2,5 fa/Fa= 0.60 Horizontal brace Pmax=V= 741 lb (kl/r)= (k * l.horiz)/r min = (1 x 42 in) /0.405 in = 103.7 in SINCE Fe>Fy/2, Fn=Fy*(1-fy/4fe) = 26,916 psi fa/Fa= 0.19 1YPE A SR-SAFETY SYRINGES <= 1.33 OK <= 1.33 OK Fe= piA2*E/(kf/f)A2 = 27,075 psi Pn= AREA*Fn = 0.278in"2*26916 psi = 7,483 lb Page /0 of ,!> '2,..---- 4,875 lb OK Fy/2= 25,000 psi Pallow= Pn/Qc = 7483 lb /1.92 = 3,897 lb 4/2/2007 S-i-ructural Ca~ceots ~~ Engineering _ ~ 1729 S. Douglass Rd. Ste B Anaheim. CA 92806 Tel: 714.456.0056 Fax: 714.456.0066 By: BOB Project: SAFETY SYRINGES, INC. Project#: G-032807-2 Anchors Configuration: TYPE A SINGLE ROW Check overturning per section 2228.7.1 of the 2001 CBC Loads Vtrans=V= 741 lb Dl../Frame= 150 lb U/Frame= 4,ooo lb Wst=(0.9*DL+U/n)total= 4,135 lb . LL@ TOP= 2,000 lb DL/Lvl= 75 lb Frame Depth,;,D= 42.0 in Htop-lvl= 180.0 in # Levels= 2 n-transv= 1 DL *0.90= 68 lb # Anchors/Base= 2 n= 1 T Lateral Ovt Forces=E(Fi*hi)= 110,743 in-lb Fully Loaded rack SIDE ELEVATION Vtrans= 741 lb Movt= I(R*hi)*l.15 Mst= Wst. * D/2 T = (Movt-Mst)/D = 110743in-lb * 1.15 = 127,354 in-lb = 4135 lb* 42 in/2 = 86,835 in-lb = (127354 in-lb -86835 in-lb)/42 in = 9651b Top Level Loaded Only Critical Level= 2 Anchor Vtop= 2.S*ca*I(DL +LL@top/n-transv)/(R*l.4) = 0.1786 * (75 lb+ 2000 lb/1) = 371 lb Mst= 0.9*(DL-total + Lltop/n) *D/2 = (2000 tb/1 + 67.5 lb*2) * 42 in/2 = 44,835 in-lb Hgt @ Lvl 2= 180.0 in Movt= Vtop*Htop*l.15 = 370.595 lb* 180 in* 1.15 = 76,713 in-lb T= (Movt-Mst)/D = (76713 in-lb-44835 in-lb)/42 in = 7591b Check (2) 0.5" x 3.375" Embed RAMSET REDHEAD TRUBOLT anchor(s) per base plate. Special inspection is not provided per ICBO ESR 2251. Fully Loaded: Top Level Loaded: Pullout capacity=Tcap= 1,935 lb Shear capacity=Vcap= 2,965 lb Tcap*Phi*S= 2,574 lb Vcap*Phi*S= 3,943 lb L.A. City Jurisdiction? NO Phi= 1.33 Spacing Coeff=S= 1.0 (483 lb/2574 lb)l'l.66 + (185 lb/3943 lb)Al.66 = (380 fb/2574 lb)Al.66 + (93 lb/3943 Jb)Al.65 = 1YPE A SR-SAFETY SYRINGES Page ( / of ~ 2..---- 0.07 0.04 <= 1.0 OK <= 1.0 OK 4/2/2007 Structural ·ca.nc~pts ~,;;;? Engineering ~ 1729 S. Douglass Rd, Ste B Anaheim. CA 92806 Tel: 714.456.0056 Fax: 714.456.0066 By; BOB Project: SAFETY SYRINGES, INC. Base Plate Configuration: TYPE A SINGLE ROW Section Baseplate= 8 x 5 x 0.375 Eff Wiclth=W = 8.00 in Eff Depth=D = 5.00 in Column Wiclth=b = 3.00 in Column Depth=dc = 3.00 in L = 2.50 in Plate Thickness=t = 0.375 in Down Aisle Loads P = 2,075 lb Axial stress=fa = P/A = P/(D*W) = 52 psi a= 3.00 in Anchor c.c. =2*a=d = 6.00 in N=# Anchor/Base= 2 Fy = 36,000 psi Mbase=Mb = 0 in-lb Ml= wLA2/2= fa*LA2/2 = 162 in-lb MomentStress=fb = M/S = 6*Mb/f(D*BA2] = 0.0 psi Moment Stress=fb2 = 2 * fb * L/W = 0.0 psi Moment Stress=fbl = fb-fb2 = 0.0 psi M3 = (1/2)*fb2*L *(2/3)*L = (1/3)*fb2*L A2 = o in-lb S-plate = (l)(tA2)/6 = 0.023 inA3/in fb/Fb =; Mtotal/[(S-plate)(Fb)] = 0.19 OK Tanchor = (Mb-(P*0.9)(a))/[(d)*N/2] = -934 lb No Tension TYPE A SR-5AFl:1Y SYRINGES M2= fbl*LA2)/2 = O in-lb Mtotal = Ml+M2+M3 = 162 in-lb/in Fb = 0.75*Fy*1.33 = 35,910 psi Tallow= 1,164 lb Page / l, of .3 v Project#: G-032807-2 . Downaisle Elevation OK 4/2/2007 Structural ·C;ncepts ~ Engineering ·· 172.9 S. Douglass Rd, Ste B Anaheim, CA .92806 Tel: 714.456.0056 Fax: 714.456.0066 By: BOB Project: SAFETY SYRINGES. INC. Project#: G-032807-2 Slab on Grade Configuration: TYPE A SINGLE ROW The slab is designed per UBC 1922 to carry the puncture stress of the post as wen as the upward soil reaction from the soil . j..-c y L SLAB ELEVATION Base Plate B= 8.00 in D= 5.00 in Load Case 1: Product + Seismic Product DL= 75 lb Product LL= 2,-000 lb Puncture !Section 1922.5, Eqtn 22-9 width=a= 3.00 in depth=b= 3.00 in ... ·.·.·.·.·.·.~··· . . . • • • • . . • . . . slab ~-... -.. .. . . . .. . . . . . . . . r: . . . . . . . . . . . : . f ____ a __ 7 ___ ! . : .. ••• 1 [J 1 ••• -:-: 1 o.-: b e •••• .. • .. • t I .... • • ·:·:-:-: : .cross: • • ----·c ----J ·Aisle . .. . ..... . .D . . ·.··r · · · · · · · · · · · ·1····· ·· •••• •• !i)· •• ••••• ·• B • •• ·•• •• ....... . • • • : -: -: • : • : -: • • • • • : Down Aisle · · Baseplate Plan View Concrete fc= 2,000 psi tslab=t= 5.0 in phi=0= 0.65 Soil fsoil= 1,000 psf Movt= 127,354 in-lb Frame depth= 42.0 in eff. baseplate width=c= 8.00 in eff. baseplate depth=e= 5.00 in P-seismic=E= (Movt/Frame depth)*l.4 = 4,2451b Pse=DL+LL+E/1.4= 5,107 lb (Strength Design Loads) Pu= 1.1 *(1.2PDL + 1.0PLL + 1.0*E) (Sec 1612.2.1, EQ 12-5) Fpunct= 2.66*phi*sqrt(fc) = 6,969 lb = 77.3 psi Apunct= [(c+t)+(e+t)]*2*t fv/Fv= Pu/(Apunct*Fpunct) = 230.0 jnA2 = 0.39 < 1.33 OK Slab Bending !Per UBC 1922.7.2. Asoil= {Pse*144)/(fsoil) L= (Asoil)"0.5 y= (c*e)A0.5 + t*2 = 735 inA2 = 27.11 in = 16.3 in x= (L-y)/2 M= w*xA2/2 S-slab= l*t"2/6 = 5.4in = (fsoil*x"2)/(144*2) = 4.17in"3 Fb= S*(phi)*(fc)"0.5/1.4 = 101.0 in-lb fb/Fb= M/(S-slab*Fb) = 104.0 psi (Sec 1922.5.1) = 0.233 < 1.33,OK Load Case 2: Static Loads PDL= 751b PLL= 2,000 lb Ps= DL+LL = 2 075 lb , Puncture !Section 1922.5, Eqtn 22-9 Pu= 1.4*PDL + 1.7*PLL (Sec 1909.2.1, EQ 9-1) Fpunct= 2.66*phi*sqrt(fc) = 3,505 lb = 77.3 psi Apunct= [(c+t)+(e+t)]*2*t fv/Fv= Pu/(Apunct*Fpunct) = 230 inA2 = 0.20 < 1.0OK Slab Bending !Per UBC 1922.7.2 Asoil= (Ps*144)/(fsoil) L= (Asoil)"0.5 y= (c*e)"0.5 + t*2 = 299 jnA2 = 17.29 in = 16.3 in X= (L-y)/2 M= w*x"2/2 S-slab= l*t"2/6 = 0.5in = (fsoil*x"2)/(144*2) = 4.17 in"3 Fb= S*(phi)*(fc)"0.5/1.7 = 0.8in-lb fb/Fb= M/(S-slab*Fb) = 85.0 psi (Sec 1922.5.1) = 0.002 < 1.0,OK TYPE A SR-SAFETY SYRINGES Page (j of ,.3 2,---4/2/2007 Structural . C~nc~~s . ~~ Engineering • -~ 1200 N. Jefferson Ste. Ste F Anaheim, CA 92807 Tel: 714.632.7330 Fax: 714.632.7763 PUSHBACK RACK ANALYSIS Structurai ·c~nc~pts ~ Engineering ··· · 1729 S_ Douglass Rd, Ste B Anaheim, CA 92806 Tel: 714.456.0056 Fax: 714.456.0066 By: 808 Project: SAFETY SYRINGES, INC. Project :ii: G-032807-2 Design Data 1) The analyses conforms to the requirements of the 2001 CBC, utilizing division X of chapter 22 and section 1630.2 2)Transverse brac-ed frame steel conforms to ASTM A570, Gr.50, with minimum strength, Fy=50 ksi Longitudinal frame beam and connector steel conforms to ASTM A570, Gr.SD, with minimum yield, Fy=SO ksi All other steel conforms to ASTM A36, Gr. 36 with minimum yield, Fy= 36 ksi 3) Anchor bolts shall be provided by installer per ICBO reference on plans and calculations herein. Instai!cr rnus: provide any special inspection as called out on plans or calculations, or as required by the ICBO report indicated herein. 4) All welos shall conform t;o AWS pro;;w1_1~, 1).ti!izlng E70l()( !?,lt;!ctrQ,:i~ or ~imil;:;;r, A!I. :;;._1c.h w,;;[(i:; ;;i'i;:;;ll bi:: i)i;:ifc;;rmE(i in.shop, with rio field welding 2ll0wed other than those supervised by a licensed deputy inspector, 5) The slab on grade is 5" thick with minimum 2000 psi compressive strength. Soil bearing capacity is 1000 psf. A-~ Column ,-,I / Beam +1 n _ .. / 1 n n ! -M , ll d _ _l I F~; 1 Ji-~ ~ ! [l1:', ,I __.. Oe:.7:11 L.U [Q;Llffii: Connector :=r~ff~t=-~1'1·.·-·.·.1 ..... , r ~·/,.;_-; Heigm: 1. __ • 1 • t-·-~.~-~ tse3m 1 j' 1' . ' • • • • • • J Spacing r--1 Bc:5,:-Fiat;;; .=inri , m,ccc j , . • • . , , / I L II [ · · ' · ' · · -j f · -: · · · ' · IJ /; {, j j 1i 1 i' "·""'o--e }-,y1 I I I j ·~ r 1 .,., .. , h r, i ~1-1· l'I Beani Ill 1 I , -,;::;f-----{:,,.,l I ,, i j jj Lc:rigti", JU___J_il i j'i V 1i I t .~ ~· ~ ~ -= ~1 !l C Front View: Down Aisle (Lonoitur:fo"1an Frarne Height Horizontai Diagonal Brace jli 1! ll ~-t... .. .,,--, .:-.,..,.-.-.~~:-,i.,--7"',ts 1--i~~-c ... {n ~rc.i Qcc1,"1r1orj 0\AJH,.hin tho autrlolhJµ~ r~f tho ?rtni ,(61~i'f~ ~';'·vi :\;HJt}-\ n, 1P 11 :; -; :;.,..._,. -:.... ........ ,; ,-1r._.,;: 1'"--: P t ~I ......,t~ 1 U ,_ ~...111'::f 1~~ ;r•,n~. Hl ~ ~ -.M ~~,._H~ .~...,t -'-1', 4..: 1"'--~"VV J.. ~_,.,._ -;..;:_; j~ ~'.' ~..._-,; 1 ~~-t,..,.. ~a! _______ _i .i..---L-L.i--L-....J ;_....i. ___ ._ ____ ,L __ _.J ___ _; ___ .._ ,c __ J..L L __ .•. ..;, __ !') __ ;_ :nA ____ ,C_--1.. _______ 1_ -;-__ ..i..:!.i.---.i....- iii IJ Building official rnust ctpprovc find/ ~..:.ubu1i j,_ -( ,_ :._ . !.,_;: .. =========-=---= -~·o,-~·--~--·-····· -.-: -,=-··----~----·---· .•• ,--:: ------,: ,,., ~I ii Structural Co~ce~s ~-/J Engineering -~ 1729 S. Douglass Rd. Ste B Anaheim. CA 92806 Tel: 714.456.0056 Fax: 714.456.0066 By: BOB Project: SAFETY SYRINGES, INC. Project#: G-032807-2 Configuration & Summary: TYPE D&.G PUSHBACK EXTERIOR T 86" 180" t 180" 88" I -_, . ~-r--100" ---~ Seismic Zone #BmLvls 4 (Na=1.0) 2 Tiong=0.26 sec/ Tshort=0.15 sec Component Column Fy=S0 ksi Column Backer None Beam Fy=50 ksi Beam Connector Fy=50 ksi Brace-Holizontal Fy=S0 ksi Brace-Diagonal Fy=50ksi Base-Plate Fy=36 ksi Anchor 2 oerBase Slab Level ,P~el BeamSpcg 1 1,600 lb 88.0in 2 1,600 lb 86.0in Frame Depth! Frame Height/ # Diagonals Beam Length I Frame Type 38in I 180.0 in I 3 108in I Intrconnected Description LMT LM20/3x3x14ga P=1675 lb, M=10455 in-lb None None Struc C3x.3.5 w/(2) front to back brace(s) Lu=35.6 in I Capacity: 36301b/pr Lvl 1: 3 pin OK I Mconf!=8492 in-lb I Mcap=16922 in-lb LMT 1-1/2x1-1/4x14ga LMT 1-1/2xl-1/4x14ga 8x5x0.375 I Rxity= o in-lb 0.5" x 3.375" Embed RAMSET REDHEAD TRUBOL T ICBO ESR 2251 No Inspection (T =O lb) 5" thk x 2000 psi slab. 1000 psf Soil Bearing Pressure Brace 56.0in 56.0in 56.0in I Story Force f Story Force Transv Longit. 1051b 831b 2081b 1631b Total: 313 lb 246 lb Column f Axial 1,675 lb 8381b Column I Conn. Moment Moment 10,455 "# 8,492 "# 3,513 "# 3,265 "# STRESS 0.42-OK N/A 0.44-OK 0.5-OK 0.05-OK 0.19-OK 0.16-OK 0-OK 0.17-OK Beam Connector 3 pin OK 3pin OK I REAR EXTERIOR BEAMS CONSIST OF LBF354 BEAM, SAME LOADS, SEE CALCS FOR ANALYSIS. -----~ Notes TYPE D¢G ext-SAFETY SYRINGES Page / {,, of ·3, '1--4/2/2007 j S-i-ruc-rural Co~ce~-i-s ~;;j Englneering . -~ 1729 S. Douglass. l<d. Ste B Anaheim. CA 92806 Tel: 714.456.0056 Fax: 714.456.0066 By: BOB Project: SAFETY SYRINGES. INC. Project#: G-032807-2 Configuration & Summary: TYPE D&.G PUSHBACK INTERIOR * Seismic Zone 4{Na=1.0) Tiong=0.26 sec / Tshort=0.15 sec Cc-rr-.po;;ent Co!umn Column Backer Beam Beam Connector Braes-Horizontal --. , ... r,;·;•r<T' ,111.,_,,,_, S!ab 1 ' T 86" 180" t 88" J T V 56" + \ 80" 56'' t \ V 56" l-- ~r I ~ --r--11s" ---~ ,fe3s" -,.J # Bmlvts Frame DepthJFrame Height! # Diagonals Beam Length I Frame Type 2 38 in I 180.0 in I 3 118in I Intrconnected Description l STRESS Fy=50 ksi LMT LM20/3x3x14ga P=3275 lb, M=11975 in-lb I 0.63-OK None None None ! N/A Fy=50 ksi Li'vlT LBF454/4.5"deepx2.75"x0.075" Lu=1:t8 in ! Capacity: 4605 lb/pr l 0.69-OK P-;=50 ksi Lvl 1: 3 ptn OK I Mconn=12.574 in-lb I 1J1cap=1692.2 u1-1b ! U.74-'0K ry=50-kst LMT 1-1/2x1-1/4xJ4ga l CL1-0K -.. . ' --Q .. _jn-Or-.. Fv=-3-5 ksi Fndty= 8000 in-!b 0.74-0K r';:ao,e ( 7 ot 3 't. 41!.!cJJUI ----4-~½_-~ 172.9 S. poua\a5s f-211_ St.a .B Anaheim, CA .92806 Te~: ~/14.456.0056 Fax: 7i4.456.0066 , .. .-., ., ... ,.,,,.,. , ...... ,.,,,., Larerai anaiysis ls perrormed wfrh regard to sections 2228.5.2 and 1630.2 ofrhe 2001 CBC. Bese shear is highest of: 1) Cv*I*\A//(R~T*l.4) (EQ 30-4) <= 2.5*Ca*I*\AJ/{R*1.4) (Eq 30-5) ··n n 1 ·nkr-::.*TiK\/il/1 ,.t.1 1.:::.~ '2f'l ... t:\ VfQ30-7:::::. G.GJ:i 11-trCiiSV..,:;; 2 v1:rattsw:,; Base. Sfrt,-1n· Cneff ~-(>:D-L + >:f C/t·1-tnH1~v} = 0-1"186"' !i50 lh 4-6400 !hf:11 I= 1.0 CV.; G.64 _____ L_-e_VP=J __ ~ _____ LL ____ ~-~ Ll/{n-tra~sy) ~y-DL -=~-~--h_i ~-----·-'ll=*=h=i ~=~--~-F_i _______ fi_J*_·h_.i _ ___,, 1 3f200 ib 11600 lh 75 Jt, 88 fn 1471-400 200 .. 9 ib 17,579-# 3,200 lb LL ---------------~-~------.. 1 3,200 lb 7 1.700 lh 1/iOO lh 3 ~00 lb 150lb ::: 0.1403 ,r (15u II:;+ G400 tt,/ :') 751h 15Dlb BB in 17-4in W=3350 ib 438,650 i47140C ;,g1.4so 438,850 5981b (LongiturJinal ) R==-5.6 117.1 lh 47Ulb .-.. , ~~. u · .... -- :Z:=86,775 ~ -~ ;I uC:L,d ~: ·~ \....#oncepts -' -C:nglneerlng 172.9 S~ Doug\ass Rd. Ste B Anaheim, CA 92806 Tel: 714_456_0056 FC!.,·C "?}Lf--456.0066 By: BOB Projec-r: SAFETY SYl<INGES, INC. D6term1ne tne-story' moments by app:ying porra: analysis~ The. base piatc. 1s assurnec1 to provide pan:inl fixity. \/long= 470 ib Vcoi=Vlong/2= 235 lb F.!.= FZ= 312 lb F3= (J {b -. ---·--~ . ...-;. .. -· ·---·_,_..,_ ••· .. ··--· .. ~ •• --...,:i....,,______ -- f..::--. . '----------- Front-View hl-eff= h1 ,.. beam clip h::lght/2 -= 85 in Proje::, ,:::;_ G-032807-2 Typ;ai no;m: :n,;4-; Dtiwa cola:r,;;s: .,,...._,,. t -------------... lop "i..iicw = 9/i5S in-ib "i/~O: MbaSE:-ei,-Minimum of Mbasc-m&:< ,md Moo:.:;c-v = a.non in-111 i, ., ... ~ i ;. ... ,,., :.:- -= ii,975 in-tb .... . .. . ·-~ I '11.!:!~..'1":I l""i•/1\JIJ'Jl~I }.! ;_ I • • ... ~.· •., -• =: 6,7to in-lb fvJseis(2-2)= (6710 rn-ib + o rn-Jb)/2 T I n2 r ; 8aan1 to Colurnn Bevation !-·--------~--.. -·----··-· .. -·--. L,.,..,...._ .•.•• --·---------------------.---'------.-----------------------------------, :: c=,.f-EL hl -· .. ··-. ";;-;: .... ·-~~ .... ,;-,-;::: .:;,,~.~;:..' ... ::: ;-::.,,,, .. ._..;:...;. :\:--<1;;;1i L:Jad 3.77.5 lb 0~-1=~-:;:: n.-r -:::-u ... r--es ------------------------------------~ Colurnn Mornent. i 1.175 ln-lb t:: --:r. :., :: '"':' t\l "' "' Mseismic 9.3~3 in-lb -::-':"""""r" :.-:~-. ·"':·'·'·' "' "·' Mend-fixity Mconn 3.23:J in-lb .:; p;:; o+~ 'c_.---·-. -----------c·-··--------------------------------------- 17 ,,,::,,· ........... , ~-"'-••. •,, __ , ~ 11 LJ\J1L!1 \.A( ·r \..--""' ancepts ,-,=.::::-------7 --:i _..J!";; ~ .. ..-.ng:neenng ~,::_ ,i' -----:::7 ~729 S~ Dv1.n-1:u::)~ Rd, Ste B Anahelm, CA 92806 Tei: 714.456.0056 Fax: 714.456.0066 Sy: BOB ProJect: SAFETY SYi<l~~GES, INC. Project J:;: G-032807-2 Column Configuration: TYPE D&G PUSHBACK INTERIOR Conforms ro the requirements of Cnaprer C5 cf ma 1996 AlSI Coid Formed Sceei Design rv;anuai for como;ned bending and ax1ai foads. Section: LMT I.M20/3x3x14ga Sx = 0.753 ,nr-.3 rx = 1.326 in 2f= :Lt7 Iy = D.749 inA4 Sy = 0.493 in''·3 1y = 1.080 in Fy= 50 ksi Cmx= C.f5 Kx = 1.2 Lx = 55.0 in Ky= 1.0 Ly= 56.0 in Cb= ~)J (Corumn stresses@ le\ret l) KxLx/rx = 1.2*88"/1.326" ;:; 79,6 = 45.91<'.si P/Pa= > Q.15 Pno= Ae*Fy = 0.643 inAZ *50000 psi = 32,150 lb KyLy/ry = 1*56"/1.08" Fy/2:= 25:l} ksi = {l/[l-(l.92~3275 {b/2:9SG3 lb)]}-~ -1 = 0.79 Pao= Pno/.Qc = 32150lb/ 1. 92 = 15,745 lb = 29,503 lb (3275 lb/12185 lb)+ (0.85*11975 in-lb)/(22545 in-lb*0.79) = (3275 lb/l.6745 lb) + (U97;;i in-lb/22545 in-JI;>) = 0.84 Fe> Fy/2 Fn= Fy{l-Py/4Fe) 36.4-Ksi = 12,185 lb Myield=My= Sx*Fy < 1.33, OK = 0,753 irJA3 :k 50000 p$[ = 37,650 in-lb (EQ CS-1) (EQ C5-2) Structural ·co~c~pts ~ Engineering ··----V 1729 S. Douglass Rd, Ste B Anaheim, CA 92806 Tel: 714.456.0056 Fax: 714.456.0066 By: BOB Project: SAFETY SYRINGES. INC. Project tt: G-032807-2 Beam Configuration: TYPE D&G PUSHBACK INTERIOR The beam to column connection is assumed to provide partial end fixity for the beam frame. 1 ne end moment ca1cu;ateo nerein 1s aaaea to the lateral force force portal moment when analyzing the connection capacity. Designed per section 2228 of the 2001 CBC Tne imp<ici: io<1d on the beam is addressed by inciuding the Impact i=aci:or "a'' in the determination of the beam center bending stress. Bending Beam Member= LMT LEF454/4.5"C:,eepx2.75",.-0.075" Beam at Level= 1 Ix= 2.753 in-"4 Sx== 1.141 in,...,_3 Length=L= 118.0 in Lu= 118Jl in "io End Fixit'{= 2.0 % Mcenter= 6*(wL-" 2(8) = 0.864*(wL A2/8) f-"iends= 0*Mmax{fixed ends) = {wL -"2/12)*0,2 = O.Ol67~WL"2 Fb= 0.6 * Fy = :;io:ooo 9si Fb-eff= 30,-000 psi Live LoadjPair= 3,:zoo ib Mcenter= 0.108 * wL"2 = 20,$94 in-lo M= 20,894 in-lb fb= (M/Sx)/a Defl-allOW=L/ 180 = 0 .. 656 H1 Be.::;m Weight= 4.0 !b/ft Thitk.nas~ D.D75 in £earn Shape= Step = 0.864 Mcenter= Mcenter(sirn9Ie enos}-0*F"fcenter(fixoo end$) = wU'2!8-(0.2 * wL A2/12) = wLA2/8 -wL-"2/60 = 0.108 * wLA2 Dead Load/Pair= (4 lb/frJ .,.. 2 ~ i18 in/12 Mends= 0.0167*wL-"2 = J;23l in-Ip fb/Fb= 20928 psi/30000 psi G.70 Def!= !3"' [SwL "4/(384"'E*Ix)] 0.373 in <= 0.656 in, OK Dist Load=w= 13.9 !b/ln A1lowabfe load per beam pair= 4,605 Ji; Page J /./of } -i....-- Structural ·co~c~pts ~ Engineering ~ 1729 S. Douglass l<d, Ste B Anaheim, CA 92806 Tel: 714.456.0056 Fax: 714.456.0066 By: BOB Project: SAFETY SYRINGES, INC .. Project#: G-032807-2 Beam Configuration: TYPE D&G PUSHBACK EXTERIOR The beam to column connection is assumed to provide partial end fixity for the beam frame. The end moment calculated herein is added to the lateral force force portal moment when analyzing the connection capacity. Designed per section 2228 of the 2001 CBC The impact load on the beam is addressed by induding the Impact Factor "a" in the determination of the beam center bending stress. Section Properties Loads Beam Member= Struc C3x3.5 Beam at Level= 1 Beam Weight= 4.0 lb/ft: Thickness= 0.130 in Beam Shape= Channel Beam Type= Structural Ix= 1.475 inA4 Sx= 0.983 inA3 Length=L= 108.0 in Lu= 35.6 in d/Af= 8.78 Impact Factor (a)=[l-(25%/2)]= 0.875 % End Rxity= 20 % 0= 0.2 Mcenter= B*(wLA2/8) = 0.864*(wlA2f8) Mends= 0*Mmax(fixed ends) = (wl A2f12)*Q.2 = 0.0167*wL A2 Fb= 0.6* Fy = 30,000 psi Fb-eff= 30,000 psi CoeffB= 0.108/0.125 = 0.864 Mcenter= Mcenter(simple ends) -0*Mcenter(fixed ends) = wlA2/8-(0.2 * wlA2/12) = wLA2/8 -wLA2/60 = 0.108 * wLA2 Fy= 50,000 psi Fb' = 12,000/(lu*d/Af) = 12,000/(35.6*8.78) = 38,392 psi Live Load/Pair= 1,600 lb Mcenter= 0.108 * wLA2 = 9,751 in-lb Dead Load/Pair= ( 4 lb/ft) * 2 * 108 in/12 = 721b Dist Load=w= 7.7 lb/in Bendin M= 9,751 in-lb fb= (M/Sx)/a = 11,337 psi Bending Capcity= 4,328 lb/ pair Deflection Defl-allow=L/ 180 = 0.600in Deflection Capacity= 3,630 lb/Pair Mends= 0.0167*wLA2 = 1,508 in-lb fb/Fb= 11337 psi/30000 psi = 0.38 <= 1.0, OK Deft= 6 * [SwLA4/(384*E*Ix)) = [5*7.7 lb/in*(lOS in)A4/(384*29.5x10A6 psi * 1.475 in/\4)]*0.864 = 0 .. 271 in <= 0.6 in, OK <=== Critical Allowable load per beam pair= 3,630 lb lYPE DtG ext-SAFElY SYRINGES 4/27/2007 Structural ·c· ... ts ngineering 729 S. Douglass Rd, Ste B Anaheim, CA 92806 Tel: 714.456.0056 Fax: 714.456.0066 By: BOB Prqject: SAFE1Y SYRINGES, INC. 3 Pin Beam to Column Connection lYPE D&G PUSHBACK INTI:R!OR Mconn max= 12,574 ln-lb Load at level 1 Connector Type= 3 Pin Shear Capacity of Pin Pin Diam= 0.44 in Fy= 50,000 psi Ashear= (0.438 in}''2 * Pi/4 = 0,1507 jnA2 Pshear= 0.4 * Fy * Ashear = 0.4 * 50000 psi* 0.1507inA2 = 3,014 lb Bearing Capacity of Pin Per thei9% AlSI Cold Formed Steel Manual, Sec E3.3: tcol= 0.075 in Omega= 2.22 Fu= 65,000 psi a= 2.22 Pbearing= alpha * Fu * diam * tcot/Omega = 2.22 * 65000 psi * 0.438 in * 0.075 ln/2.22 = 2,135 lb < 3014 lb Moment capacity of Bracket Edge Distance=E= 1.00 in Pin Spacing= 2.0 in C= Pl+P2+P3 ttlip= 0.18 in = Pl +Pl *(2.5"/4.5'1+P1 *(0.5"/4.5") = 1.667 * P1 Mcap= Sclip * Fbending = 0.127 in"3 * 0.66 * Fy = 4,191 in-lb Pclip= Mcap/(1.667 * d) C*d= Mcap = 1.667 = 4191 in-lb/(1.667 * 0.5 in) = 5,028 lb Thus, Pl= 2,135 lb Mconn-allow= [Pl *4.5"+P1 *(2.5"/4.5")*2.S"+Pl *(0.5"/4.5")*0.5"]*1.33 = 2135 LB*[4.5"+(2.5"/4.5")*2.5"+ (0.5"/4.5")*0.5"]*1.33 = 16,922 in-lb > Mconn max, OK TYPE DtG /Nt-5AFETY SYRINGES Page t!)}-of J-'L- Fy= 50,000 psi Sclip= 0.127 inA 3 d= E/2 = 0.50 in Project :1:1: G-032807-2 4/2/2007 • Structural ·c;nc~pts ~ Engineering ··· 1729 S. Douglass Rd, Ste B Anaheim. CA 92806 Tel: 714.456.0056 Fax: 714.456.0066 By: BOB Project: SAFETY SYRINGES, INC. Project#: G-032807-2 Transverse Brace Section Properties Diagonal Member= LMT 1-1/2x1-1/4x14ga Area= 0.278 inA2 r min= 0.405 in Configuration: 1YPE D&G PUSHBACK INTERIOR Horizontal Member= LMT 1-1/2x1-1/4x14ga r-1.500 in-, r1.SOOin4 Py= 50,000 psi K= 1.0 Qc= 1.92 R loin j_ Area= 0.278 inA2 r min= 0.405 in Py"' 50,000 psi K= 1.0 R JSOin J_ .Frame Dimensions Bottom Panel Height=H= 56.0 in Frame Depth=D= 38.0 in Column Width=B= 3.0 in Diagonal Member V=Vtransv= 598 lb Ldiag= [(D-B*2)A2 + (H-6")A2]A1/2 · = 59.4in Pmax= V*(Ldiag/D) = 9351b Pn= AREA*Fn "" 0.278 JnA2 * 13529 psi = 3,761 lb Pallow= Pn/Q = 3761 lb I 1.92 = 1,9591b fa/Fa= 0.48 Horizontal brace Pmax=V= 598 lb (klfr)= (k * Lhoriz)/r min = (1 x 38 in) /D.405 in = 93.8 in SINCE Fe>Fy/2, Fn=Fy*(1-fy/4fe) = 31,113 psi fa/fa= 0.13 TYPE Dil:G 1Nt-5AFETY SYRINGES <= 1.33 OK <= 1.33 OK Clear Depth=D-B*2= 32.0 in XBrace= NO SINCE Fe<Fy/2, Fe= piA2*E/(kl/r)A2 = 33,091 psi Pn= AREA*Fn (kif r)= {k * Ldiag)/r min = (1 x 59.4 in /O,<l05 in ) = 146.7in Fe= piA2*E/(kf/r)A2 = 13,529 psi Fn= Fe = 13,529psi Check End Weld Lweld= 2.5 in Fu= 65 ksi tmin= 0.075 in ~0~1 I I Typical Panel Configuration Weld capacity= 0.75 * tmin * L * Fu * 1.33/2,5 4,875 lb OK fy/2= 25,000 psi Pallow= Pn/Qc = 0,278inA2*31113 psi = 8,649 lb = 8649 lb /1.92 = 4,505 lb -i l Page JJ of )"'l.--4/2/2007 Structural ·c~nc~pts ~ Engineering -1729 S. Douglass Rd, Ste B Anaheim, CA .92806 Te!: 714.456.0056 Fax: 714.456.0066 By: BOB Project: SAFETY SYRINGES, INC. Anchors Configuration: TYPE D&G PUSHBACK INTERIOR Check overturning per section 2228.7.1 of the 2001 CBC Loads Vtrans=V= 598 lb DL/Frame= 150 lb. LL/Frame= 6,400 lb Wst=(0.9*DL+LL/n)total= 6,535 lb LL@ TOP= 3,200 lb Dl/Lvl= 75 lb DL *0.90= 68 lb Lateral Ovt Forces='E(Fi*hi)= 86,775 in-lb Fully Loaded rack Vtrans= 598Ib Frame Depth=D= 38.0 in Htop-lvl= 174.0 in # Levels= 2 n-transv= 2 . # Anchors/Base= 2 n= 1 Project l:l:: G-032807-2 --,,<---1-11,-. V T SIDE ELEVATION Movt= i:(R*hi)*l.15 Mst= Wst * D/2 T= (Movt-Mst)/D = 86775in-lb * 1.15 = 99,791 in-lb = 6535 lb * 38 in/2 = 124,165 in-lb = (99791 in-lb-124165 in-lb)/38 in = -641 lb No Uplift Top Level Loaded Only Critical Level= 2 Anchor Vtop= 2.5*Ca*I(DL +LL@top/n-transv)/(R* 1.4) = 0.1786 * (75 lb+ 3200 lb/2) = 299Ib Mst= 0.9*(DL-total + Lltop/n) *D/2 = (3200 lb/1 + 67.5 lb*2) * 38 in/2 = 63,365 in-lb Hgt @ Lvl 2= 174.0 in Movt= Vlnp*Htop*l.15 = 299.155 lb * 174 in * 1.15 = 59,861 in-lb T = (Movt-Mst)/D = (59861 in-lb -63365 in-lb)/38 in = -92 lb No Uplift Check (2) 0.5" x 3.375" Embed RAMSET REDHEAD TRUBOLT anchor(s) per base plate. Special inspection is not provided per ICBO ESR 2251. Fully Loaded: Top Level Loaded: Pullout capacity= Tcap= 1,935 lb Shear capacity=Vcap= 2,965 lb Tcap*Phi*S= 2,574 lb Vcap*Phi*S= 3,943 lb L.A. City Jurisdiction? NO Phi= 1.33 Spacing Coeff=S= 1.0 (150 Jb/3943 lb)"l.66 = (0 lb/2574 lb)Al.66 + (75 lb/3943 lb)"l.66 = 1YPE D$G INt-SAFETY SYRINGES Page rJ'f of )'1.- 0.00 0.00 <= 1.0 OK <= 1.0 OK 4/2/2007 Structural . C~nc~pts ~ Engineering --1729 s_ Douglass Rd, Ste B Anaheim, CA .92806 Tel: 714.456.0056 Fax: 714.456.0066 By: BOB Project: SAFETY SYRINGES. INC. Base Plate Configuration: TYPE D&G PUSHBACK INTERIOR Section Baseplate= 8 x 5 x 0.375 Eff Wldth=W = 8.00 in Eff Depth=D = 5.00 in Column Wldth=b = 3.00 in Column Depth=dc = 3.00 in L= 2.50 in Plate Toickness=t = 0.375 in Down Aisle Loads a= 3.00in Anchor c.c. =2*a=d = 6.00 in N=# Anchor/Base= 2 Fy = 36,000 psi P = 3,275 lb Mbase:::;Mb = 8,000 in-lb Axial stress=fa = P/A = P/(D*W) = 82 psi Moment Stress=fb = M/S = 6*Mb/{(D*BA 2J = 150.0 psi Moment Stress=fbl = fb-fb2 = 56.3 psi M3 = (1/2)*fb2*L *(2/3)*L = (1/3)*fb2*L A 2 = 195 in-lb S-plate = (1)(tA2)/6 = 0.023 inA3/in fb/Fb = Mtotal/[(S-plate)(Fb)] = 0.74 OK Tanchor = (Mb-(P*0.9)(a))/I(d)*N/2] = -140 lb No Tension TYPE Dil:G INt-SAFETY SYRINGES Ml= wLA2/2= fa*LA2/2 = 256 in-lb Moment Stress=fb2 = 2 * fb * L/W = 93.8 psi M2= fbl*LA2)/2 = 176 in-lb Mtotal = Ml +M2+M3 = 627 in-lb/in Fb = 0.75*Fy*1.33 = 35,910 psi Tallow= 2,574 lb Project#: G-032807-2 Downaisle Elevation OK 4/2/2007 S-i-ructura1 ·c~nc~p-rs ~ Engineering ·-1729 S. Douglass Rd, Ste B Anaheim, CA 92806 Tel: 714.456.0056 Fax: 714.456.0066 By: BOB Pr«iect: SAFElY SYRINGES, INC. Project :l:i: G-032807-2 Slab on Grade Configuration: TYPE D&G PUSHBACK INTERIOR The slab is designed per UBC 1922 to carry the puncture stress of the post as well as the upward soil reaction from the soil . . . . . . . . . . . . . . . 9<::. . . . .••••••••.•• slab ~-. . . . .. . . . . . . . .. .. . . . ~r:· · .. · . . .. ... ,. . . -----------. .. • .. • 1 •• ·.·.·. : [Ja7 : .·.·. -:-: 1 ~. ! b e ••• ,. • • .. I I .. • • • -:-:-:-: : .cross : • • ----·c ----· ·Aisle .. .. .. ...... Concrete fc= 21000 psi tslab=t= 5.0 in phi=0= 0.65 Soil t X -,_,. -Ly-- ·a .. . ·.··r ....... -...... ,.·.· .. · · ..... !I'.· ... ·.·. B •·• · •.• •• ·t ... . .. .. . ............ ' .. . •. •• •. ·. •• •• •. • • ,Down Aisle fsoil= 11000 psf Movt= 99,791 in-lb Frame depth= 38.0 in SLAB ELEVATION Base Plate B= 8.00 in D= 5.00 in Load case 1: Product + Seismic width=a= 3.00 in depth=b= 3.00 in Baseplate Plan View eff. baseplate width=c= 8.00 in eff. baseplate depth=e= 5.00 in Product DL= 75 lb Product LL= 31200 lb P-seismic=E= (Movt/Frame depth)*l.4 = 3,6771b (Strength Design Loads) Pse=DL+LL+E/1.4= 5,901 Jb Puncture !Section 1922.5, Eqtn 22-9 Pu= 1.1 *(1.2PDL + 1.0PLL + 1.0*E) (Sec 1612.2.1, EQ 12-5) Fpunct= 2.66*phi*sqrt(fc) = 7,663 lb = 77.3 psi Apunct= [(c+t)+(e+t)]*2*t fv/Fv= Pu/ (Apunct*Fpunct) = 230.Q jnA2 = 0.43 < 1.33OK Slab Bending I Per UBC 1922.7.2 Asoil= (Pse*144)/(fsoil) L= (Asoil)A0.5 y= (c*e)A0.5 + t*2 = 850 jnA2 = 29.15 in = 16.3 in X= (L-y)/2 M= w*x.A-2/2 S-slab= l*tA2/6 = 6.4 in = (fsoil*XA2)/(144*2) = 4.17inA3 Fb= 5*(phi)*(fc)A0.5/1.4 = 142.9 in-lb fb/Fb= M/(S-slab*Fb) = 104.0 psi (Sec 1922.5.1) = 0.330 < 1.33,OK Load case 2: Static Loads PDL= 751b PLL= 3,200 lb Ps= DL+LL = 3,275 lb Puncture !Section 1922.5, Eqtn 22-9 Pu= 1.4*PDL + 1.7*PLL (Sec 1909.2.1, EQ 9-1) Fpunct= 2.66*phi*sqrt(fc) = 5,545 lb = 77.3 psi Apunct= [(c+t)+(e+t)J*2*t fv/Fv= Pu/(Apunct*Fpunct) = 230 in/\2 = 0.31 < 1.0OK Slab Bending I Per UBC i922.7.2 Asoil= (Ps*144)/(fsoil) L= (Asoil)A0.5 y= (c*e)A0.5 + t*2 = 472jnA2 = 21.72in = 16.3 in X= (L-y)/2 M= w*xA2/2 S-slab= 1 *t" 2/6 = 2.7in = (fsojl*X/\2)/(144*2) = 4.17 jnA3 Fb= S*(phi)*(fc)A0.5/1.7 = 25.2 in-lb fb/Fb= M/(S-slab*Fb) = 85.0 psi (Sec 1922.5.1) = 0.071 < 1.0,OK TYPE DI/CG 1Nt-5AFETY SYRINGES Page Zt:> of :J'Z--4/2/2007 Structural ·co~ce~s ~;j Engineering -~ 1729 S. Douglass Rd, Ste B Anaheim, CA 92806 Tel: 714.456.0056 Fax: 714_456.0066 By: BOB Project: SAFETY SYl<INGES. INC. Project#: G-032807-2 Configuration.&. Summary: TYPE E&H PUSHBACK EXTERIOR ~ T 86'' 180" t 88" cl Seismic Zone #Bmlvls 4(Na=1.0) 2 llong=0.26 sec/ Tshort=0.15 sec Component Column Fy=50 ksi' Column Backer None Beam Fy=SO ksi Beam Connector Fy=50 ksi Brace--Horlzontal Fy=50ksi Brace-Diagonal Fy=SO·ksi Base Plate Fy=36ksi Anchor 2 per Base Slab Level I Load Per Level BeamSpcg 1 1,600 lb 88.0in 2 1,600 lb 86,0in 180" 108" Frame Depth!Frame Height! # Diagonals Beam Length I Frame Type 54in I 180.0 in I 3 108in I Intrconnected Description LMT LM20/3x3x14ga P=1675 lb, M=10455 in-lb None None Struc C3x3.5 w/(2) front to back brace(s) Lu=35.6 in I capacity: 3630 lb/pr Lvl 1: 3 pin OK I Mconn=8492 in--lb I Mcap=16922 in--lb LMT 1-1/2x1-1/4x14ga lMT 1-1/2xl-1/4x14ga 8x5x0.375 l Fixity= o in-lb 0.5" x 3.375" Embed RAMSET REDHEAD 1RUBOLT ICBO ESR 2251 No Inspection (T=O lb) 5" thk x 2000 psi slab. 1000 psf Soil Bearing Pressure Brace 56.0 in 56.0in 56.0in I Story Force I Story Force Transv Longit. 105 lb 831b 2081b 1631b Total: 313 lb 246 lb Column I Axial 1,675 lb 8381b Column f Conn. Moment Moment 10,455 "# 8,492 "# 3,513 "# 3,265 "# STRESS 0.42-0K N/A 0.44--0K 0.5-0K 0.1-0K 0.21-0K 0.16-0K 0-0K 0.16-0K Beam Connector 3 pin OK 3 pin OK Notes I REAR EXTERIOR BEAMS CONSIST OF LBF354 BEAM, SAME LOADS, SEE CALCS FOR ANALYSIS. 1-------' TYPE E$H ext-SAFETY SYRINGES Page ?,,7 of :n .. 4/2)2007 • .- Structural ·ca~c~pts ~/J Engineering -~ 1729 S. Douglass Rd, Ste B Anaheim. CA 92806 Tel: 714.456.0056 Fax: 714.456.0066 By: BOB Project: SAFETY SYRINGES. INC. Project :J:t: G-032807-2 Configuration & Summary: TYPE E&.H PUSHBACK INTERIOR T 86" 180'' t 88" J ' Seismic Zone #BmLvls 4(Na=l.O) 2 Tlong=0.26 sec/ Tshort=0.15 sec Component Column P.;=50 ksl Column Backer None Beam Fy=SO ksi Beam Connector Fy=50 ksi Brace-Horizontal Fy=SO ksi Brace-Diagonal . Fy=50 ksi Base Plate Fy=36ksi Anchor 2 per Base Slab Level I Load Per Level BeamSpcg 1 3,200Jb 88.0 in 2 3,200 lb 86.0 in Notes TYPE Elf:H !Nt-SAFETY SYRINGES 180" 108" Frame DepthfFrame Height! # Diagonals Beam Length I Frame Type 48in I 180.0 in I 3 108in I Intrconnected Description STRESS LMf LM20/3x3x14ga P=3275 !b, M=19975 in-lb 0.92-0K None None N/A LMf LBF454/4.S"deepx2:7S"x0.075" Lu=108in I capacity: 5041 lb/pr 0.63-0K Lvl 1: 3 pin OK I Mconn=16294 in-lb I Mcap=16922 in-lb 0.96-0K LMT 1-1/2x1-1/4x14ga 0.15-0K LMf 1-1/2xl-1/4x14ga 0.38-0K 8x5x0.375 I FJXity= 0 in-lb 0.3-0K 0.5" x 3.375" Embed RAMSET REDHEAD 1RUBOLT ICBO ESR 2251 No Inspection (f =0 lb) 0-0K 5" thk x 2000 P,Si slab. 1000 psf Soil Bearing Pressure Brace 56.0in 56.0in 56.0in Total: I Story Force I Story Force Transv Long it. 201 lb 1581b 3971b 312lb 5981b 4701b Page ~ of }"'l- Column I Axial 3,275 lb 1,638 lb 0.31-0K Column I Conn. Beam Moment Moment Connector 19,975 "# 16,294 "# 3 pin OK 6,710 "# 6,306 "# 3 pin OK 4/2/2007 I .. • ,.., "t Structural ·CC:nc~pts ' ~/} Engineering -~ 1729 S. Douglass Rd, Ste 8 Anaheim, CA 92806 Tel: 714.456.0056 Fax: 714.456.0066 By: BOB Project: SAFETY SYRINGES, INC. Project i:i: G-032807-2 Configuration &. Summary: TYPE f PUSHBACK EXTERIOR ' T 86" 180" t 88" ' J ' Seismic Zone # BmLvls 4(Na=1.0) 2 Tiong=0.26 sec/ Tshort=0.15 sec Component Column ·Fy=50ksi Column Backer .None Beam Fy=50 ksi Beam Connector Fy=50 ksi Brace-Horizontal Fy=50ksi Brace-Diagonal Fy=50 ksi Base Plate fy=36 ksi Anchor 2 per Base Slab Level I Load Per Level BeamSpcg 1 1,600 lb 88.0in 2 1,600 lb 86.0in T I 56" + 180" -56"·-. --+ 56" L 108" .}-54" ~ + Frame Depth! Frame Height! # Diagonals Beam Length I Frame Type 54in I 180.0 in I 3 108in _., Single Row Description LMT LM20/3x3x14ga P=1675 lb, M=10455 in-lb None None Struc C3x3.5 w/(0) front to back brace(s) Lu=81 in I capacity: 2500 lb/pr Lvl 1: 3 pin OK I Mconn=8862 in-lb I Mcap=16922 in-lb LMT 1-1/2xl-1/4x14ga LMT 1-1/2:x1-1/4x14ga Bx 5x0.375 I Fixity= o in-lb -0.5" x 3.375" Embed 'RAMSET REDHEAI;) TRUBOLT ICBO ESR 2251 No Inspection (T=241 lb) 5" tnk x 2000 psi slab. 1000 psf Soil Bearing Pressure Brace 56.0 in 56.0 in 56.0in I Story Force I Story Force Transv Longit. 201lb 831b 3971b 1631b Total: 598 lb 246 lb Column I Axial 1,675 lb 8381b Column I Conn. Moment Moment 10,455 "# 8,862 "# 3,513 "# 3,635 "# STRESS 0.42-0K N/A 0.64-0K 0.52-0K 0.19-0K 0.4-0K 0.16-0K 0.01-0K 0.2-0K Beam Connector 3 pin OK 3 pin OK Notes !REAR EXTERIOR BEAMS CONSisr OF LBF354 BEAM, SAME LOADS, SEE CALCS FOR ANALYSIS. 1-------' TYPE 2 deep pb ext-SAFETY SYRINGES Page 2'( of .3--i.-4/2/2007 • "' ) Structural ·c;nc~pts ~ Engineering -~ 1729 S. Douglass Rd, Ste B Anaheim, CA 92806 Tel: 714.456.0056 Fax: 714.456.0066 By: BOB Project: SAFETY SYRINGES, INC. Project#: G-0.32807-2 Configuration & Summary! TYPE F PUSHBACK INTERIOR $ ,. T 86" 180" t 88" .I - Seismic Zone #BmLvls 4{Na=1.0) 2 1long=0.26 sec/ Tshort=0.15 sec Component Colurpn Fy=SO ksi Column Backer None Beam Fy=50 ksi Beam Connector Fy=SD ksi Brace-Horizontal Fy=50 ksi Brace-Diagonal Py=50 ksi Base Plate fy=36ksi Am:hor 2 per Base Slab Level I Load Per Level BeamSpcg 1 3,200 lb 88.0 in 2 3,200 lb 86.0 in Notes TYPE 2 deep pb 1Nt-5AFETY SYRINGES T 56" + 180" 56" + 56" 1- 108" }-54" -,,J ,r Frame Depth!Frame Height! # Diagonals ~mLength I Frame Type 54in I 180.0 in I 3 108in I Single Row Description STRESS LMT LM20/3x3x14ga P=3275 lb, M=11975 in-lb 0.63-0K None None N/A LMT LBF404/4udeepx2.75"x0.075" Lu=108in I capacity: 4350 lb/pr 0.74-0K Lvl 1: 3 pin OK I Mconn=13018 in-lb I Mcap=16922 in-lb 0.77-0K lMT 1-1/2x1-1/4x14ga 0.37-0K LMT 1-1/2x1-1/4x14ga 0.78-0K --8 xs x0.375 I Fixity= 8000 in-lb 0.74-0K 0.5'' x 3.375" Embed RAMSET REDHEAD TRUBOLT ICBO ESR 2251 No Inspection (T=500 lb) 0.03-0K 5" thk x 2000 psi slab. 1000 psf Soil Bearing Pressure Brace 56.0in 56.0 in 56.0 in I Story Force I Story Force Transv Lon git. 3931b 1581b 7771b 3121b Total: 1,170 lb 4701b Paqe JU of ;,,"?.- Column I Axial 3,275 lb 1,638 lb 0.39-0K Column I Conn. Beam Moment Moment Connector 11,975 "# 13,018 "# 3 pin OK 6,710 "# 7,030 "# 3 pin OK 4/2/2007 Structural ·co~c~p-ts ~;j Engineering . -~ 1729 S. Douglass Rd. Ste B Anaheim, CA 92806 Tel: 714.456.0056 Fax: 714.456.0066 By: BOB Projec::t: SAFETY SYRINGES, INC. Pr'!)ect #: G-032807-2 Configuration & Summary: TYPE EUROPEAN PALLETS EXTERIOR T 84" 120" t T \ 54" \ t 120" 8'' 54" _I l --r 56" ,r ,}-54" -,,j ~ Seismic Zone # Bmlvls Frame Depth! Frame Height! # Diagonals Beam length I Frame Type 4 (Na=l.0) 2 54in I 120.0 in I 2 56in I Single Row llong=0.16 sec/ Tshort=0.09 sec ... Component Description STRESS Column Fy=50 ksi I.MT LM20/3x3x14ga P=538 lb, M=3110 in-lb 0.13-OK -Column Backer None None None N/A Beam Fy=50 ksi Struc C3x3.5 w/(0) front to back brace(s) Lu=42in I capacity: 8605 lb/pr 0.12-OK Beam Connector Fy=50 ksi Lvl 1: 3 pin OK I Mconn=2360 in-lb I Mcap=16922 in-lb 0.14-OK Brace-Horizontal Fy=50 ksi I.MT 1-1/2x1-1/4x14ga 0.12-OK -Brace-Diagonal Fy=50 ksi I.MT 1-1/2xl-1/4x14ga 0.24-OK Base Plate -·----. Fy=36 ksi 8x5x0.375 I Fixity= O in-lb 0.1-OK Anchor 2 per Base OS x 3.375" Embed RAMSET REDHEAD TRUBOLT ICBO ESR 2251 No Inspection (T =0 lb) 0-01< Slab 5" thk x 2000 psi slab. 1000 psf .Soil Bearing Pressure 0.1-OK Level I Load I Story Force I Story Force Column I Column I Conn. Beam Per Level BeamSpcg Brace Transv Long it. Axial Moment Moment Connector 1 1,000 lb 8.0 in 54.0in 311b 131b 1,075 lb 403 "# 2,360 "# 3 pin OK 2 1,000 lb 84.0in 54.0in 3531b 1481b 5381b 3,110 "# 2,159 "# 3 pin OK Total: 3841b 1611b Notes • TYPE EURPEAN PALlfl EXT-SAFETY SYRINGES Page 3\ of '"3 2-4/27/2007 • • • .. • Struc;;tL,Jral Concepts ~/} Engineering -~ 1729 S. Douglass l<d, Ste B Anaheim, CA 92806 Tel: 714.456.0056 Fax: 714.456.0066 By. BOB Project: SAFETY SYRINGES, INC. Project l:*: G-032807-2 Configuration &. Summary: TYPE EUROPEAN PALLETS INTERIOR -I T ' T \ I 84" 54" t t 120" 120" J 8" 54" I _l l --~ ' r-r -56" ----,} Seismic Zone #Bmlvls Frame Depth I Frame Height! # Diagonals Beam Length I Frame Type 4 (Na=l.0) 2 54in I 120.0 in I 2 56in I Single Row llong=0.16 sec/ Tshort=0.09 sec Component Description STRESS Column Fy=SO ksi LMT LM20/3x3x14ga P=1038 lb, M=5834 in-lb 0.24-0K Column Backer None None None N/A Beam Fy=50 ksi LMf LBF354/3.5"deepx2.75"x0.075" Lu=56in I capacity: 6987 lb/pr 0.29-0K Beam Connector Fy=50 ksi Lvl 1: 3 pin OK I Mconn=4480 in-lb I Mcap=16922 in-lb 0.26-0K Brace-Horizontal Fy=SO ksi LMT 1-1/2xl-1/4x14ga 0.23-0K Brace-Diagonal Fy=SO ksi LMT 1-1/2xl-1/4x14ga 0.47-0K Base Plate Fy=36ksi 8x5x0.375 I Rxity= 0 in-lb 0.19-0K Anchor 2 per Base 0.5" x 3.375" Embed RAMSET REDHEAD TRUBOLT ICBO ESR 2251 No Inspection (f =0 lb) 0.01-0K Slab S? thk x 2000 psi· slab. 1000 psf Soil Bearing Pressure 0.2-0K Level I Load I Story Force f Story Force Column I Column I Conn. Beam Per Level B~mSpcg Brace Transv Longit. Axial Moment Moment Connector 1 2,000 lb 8.0 in 54.0in 591b 241b 2,075 lb 755 "# 4,480 "# 3 pin OK 2 2,000 lb 84.0 in 54.0in 6821b 2781b 1,038 lb 5,834 "# 4,103 "# 3 pin OK Total: 741 lb 3021b Notes lYPE EURPEAN PALLET INT-SAFElY SYRINGES Page J z_ of 3 2--4/27/2007 -" •• , <• I J • i<, .. ,, ,T ';,; ·'?J ;:e, , ...... , • ...,_ -· ~,.,~.A:, i .o;;.,4._.--.~ •PJ\-..,. _; , "n"¼,,, ,,.-,,.l ,Zl"( .• ( .t .. ~;~;;:;iG;:::~ ----~ ···-. ·--T~\ . \ STORAGE= Rlll"""' I J) ¼f .{ .•• ,Vj • l ~"':-· .. ,, Tl Lm#; <-t l \ '-b---\ ~ c, 5 ~ ( Cv/-J f,Lt_ ' ~ ., if-/f-t17-at s47f 1-C. 'f-JLj-07-[s~cLl?J •\ i , :', -,,,11 5/1 / o?-{)tv;VW1L{_/arhal sh~ )cJ--s-/ruc-1-. ~ £56-,L {];TZJ IL.( I/ It ) ~ FC. ti!ZE-Jj II It ft> p/;?_E s:-1 o..-d7 -1~e 1C'-µ,J2 F ~ sf,w/01 ~TI ~ /J 5'/f? (07 ()JU W --~ ·.•::,;_·~ ! ..... ~._\··\~ ' • 1 t" . -·... r ~ }:; t,:_•;.:,. ,:;.....: .. ' ... · >t-, s,t;. •( ..>, 7 , .. ,.,_-.-.,.,.~-~ r~ SCHOOlFORM ----t----CFD FORM ----t----PE&MWORKSHEET ---T-"--r---SPEC INSP PLAN CORR ---t---t---·:::NG CORR --====1=====~~:]~f:_ESGIL CORR FIRE CORR c,j~ \ \ r.tt*;/43.J" h s!,l !-,-/'? _t ,;'*\*:~-,~~ : &_{ ~ _..., .... ~.~~~ I!. __ .,r,'J, S3'V:_ ~-·1..,,. ~~ .f~. :'"!·;_ .~-,._ ~~ ,j, ~ '.;:' ~--f , ... _ . .,_ ._ .. _ i3 ~-., ,rt;;tt .1$, ,:y:.:,.,. ... _1•t;=J.5iQ ;.::.+,.,/!$i,,\ ,.,.1 ). J. ~~-·:-::_~' -··:·· - ,· ·, t,)' r ,' :·::, •• .. ·.,, ~~ , ! ~--. in ' .l·:,- -.,..:· -!---·----n; ,;