Loading...
HomeMy WebLinkAbout2849 CACATUA ST; ; CB120142; Permit03-05-2012 Job Address: Permit Type: Parcel No: Valuation: Occupancy Group: # Dwelling Units: Bedrooms: Project Title: City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Residential Permit Permit No:CB120142 Building Inspection Request Line (760) 602-2725 2849 CACATUA ST CBAD RESDNTL Sub Type: RAD Status: ISSUED 2153702100 Lot#: 0 Applied: 01/24/2012 $40,183.00 Constuction Type: 5B Entered By: RMA Reference #: 0 Structure Type: 0 Bathrooms: Orig PC #: SMITH RES- ADD 299 SF OFFICE TO 1ST FLOOR, COVERED ENTRY 83 SF Plan Approved: 03/05/2012 Issued: 03/05/2012 Inspect Area: Plan Check #: Applicant: B & W ARCHITECTS ATTN: MAX WUTHRICH P 0 BOX 7223 RANCHO SANTA FE CA 92067 858 7 56-1788 Owner: LAFLIN-SMITH TRUST 12-06-89 2849 CACATUA ST CARLSBAD CA 92009 Building Pennit $386.99 Meter Size Add'l Building Pennit Fee $0.00 Add'l Reel. Water Con. Fee $0.00 Plan Check $270.89 Meter Fee $0.00 Add'l Plan Check Fee $37.63 SDCWA Fee $0.00 Plan Check Discount $0.00 CFD Payoff Fee $0.00 Strong Motion Fee $4.02 PFF (3105540) $0.00 Park in Lieu Fee $0.00 PFF (4305540) $0.00 Park Fee $0.00 License Tax (3104193) $0.00 LFM Fee $0.00 License Tax (4304193) $0.00 Bridge Fee $0.00 Traffic Impact Fee (3105541) $0.00 Other Bridge Fee $0.00 Traffic Impact Fee (4305541) $0.00 BTD #2 Fee $0.00 Sidewalk Fee $0.00 BTD #3 Fee $0.00 PLUMBING TOTAL $0.00 Renewal Fee $0.00 ELECTRICAL TOTAL $150.00 Add'l Renewal Fee $0.00 MECHANICAL TOTAL $0.00 Other Building Fee $0.00 Housing Impact Fee $0.00 HMP Fee $0.00 Housing InLieu Fee $0.00 Pot. Water Con. Fee $0.00 Housing Credit Fee $0.00 Meter Size Master Drainage Fee $0.00 Add'l Pot. Water Con. Fee $0.00 Sewer Fee $0.00 Reel. Water Con. Fee $0.00 Additional Fees $0.00 Green BIdg Stands (SB1473) Fee $1.00 Fire Sprinkler Fees $0.00 Green BIdg Stands Plan Chk Fee $0.00 Green BIdg Stands Plan Chk Fee TOTAL PERMIT FEES $850.53 Total Fees: $850.53 Total Payments to Date: $850.53 Balance Due: $0.00 Inspector: FINAL APPROyAL Date: (e / Clearance: NOTICE: Please take NOTICE thaf approval of your pr6ject includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively refeaed to as "fees/exactions." You have 90 days from the date this pemiit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Govemment Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition, You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which vou have previously been given a NOTICE similar to this, or as to which the statute of limitations has oreviouslv othenvise expired. 03-05-2012 City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Storm Water Pollution Prevention Plan (SWPPP) Permit Permit No:SW120019 Job Address: Permit Type: Parcel No: Reference #: CB#: Project Title: 2849 CACATUA ST CBAD SWPPP 2153702100 CB120142 SMITH ADDITION Applicant: B & W ARCHITECTS ATTN: MAX WUTHRICH P O BOX 7223 RANCHO SANTA FE CA 92067 858 7 56-1788 Lot#: Entered By: Issued: Inspect Area: Tier: Priority: Owner: LAFLIN-SMITH TRUST 12-06-89 2849 CACATUA ST CARLSBAD CA 92009 Status: ISSUED Applied: 01/24/2012 RMA 03/05/2012 1 M Emergency Contact: NORM SMITH 760 703-5193 SWPPP Plan Check SWPPP Inspections Additional Fees $50.00 $210.00 $0.00 TOTAL PERMIT FEES $260.00 Total Fees: $260.00 Total Payments To Date: $260.00 Balance Due: $0.00 FINAL, APPROVAL aEARANCI CITY OF CARLSBAD Building Pehnit Application 1635 Faraday Ave.. Carlsbad, CA 92008 76(>«)2-2717 / 2718 / 2719 Fax 760-602-8558 iiiwiw.carbbadca.gw Pian Check No, Est Valu PianCk-PeposH gj^^T^y Date SWPPP JOBADDRESS 2849 Cacatua Street :*/smcE#/UNn« 215 - 370 - 21 00 CONSTR. T»Pr v-n CT/PRQJECr# fOFUNns •BEDROOMS « BATHROOMS TENANT BUSMESS NAME Smith Residence OCC. GROUP DESCRIPTION OF WORK: toetade Squan Fleet ofilffiBcttdAmaes) Office addition of 299s.f. — (,4^ ^/6>o^ CMRAGE (SF) 634 ExisnmousE Residence PROPOSED USE Residence PATIOS (SF) DECKS (SF) IRREPIACE I AIR CONDITIONING YESin* N0| 11 YES I jNOi j FIRE SPRINKLERS YESf |N0| I APPUCMNTIUMEfPrfaary Contact) B+W Architects iVniCMflriUMEfSacMdarr Coatact) ADDRESS P.O. Box 7223 ADDRESS OTY Rancho Santa Fe STATE CA ZIP 92067 cmr STATE ZIP PHONE 858 7561788 FAX 858 7561735 PHONE FAX EMAIL bwarc@pacbeii.net EMAIL PROPERIY OWNER NAME Norm & IMonica Smith CONTRACTOR BUS. NAME Mke Freer ADDRESS 2849 Cacatua Street ADDRESS CHY Carisbad STATE CA ZIP 92009 cnY STATE ZIP PHONE 760703 5193 FAX PHONE FAX EMAIL EMAIL AROVOESIGNER NAME ft ADDRESS B+W Architects STATE Lia« 019117 CLASS cnv BUS. UC* (Sec 7031.5 Business and Professions Oode: Any Oity or County which Fequires a pennit to construct, alter, improve, demolish or r«)air any ^ructure, prior to its issuance, also requires the applicant fbr such permit to file a sieied statemetTt that he is Hcensed pursuaiit to the provisions of the Business and Profiesskxe Code} or B)at he is exempt therefrom, and the iMsisfw 7()3£5 by am applicant fbr a permit sutijecl»the applicant to a civil penalty of not more than five hundred dollars (fSCXQ). WORKERS COIWPENSATION Woitors'Convansalion DedaraHan: f fierelqr aflhn uxferpenatty BllwveandwHmaMibiaoaimcalaarcantenttoMlNnaurefcrwxkeis'coni^^ 371)0 of the Lalw Code, far tie peifcnnanoe of fteiiBrt Ibr «ihichlfe I have and will naimainwoilBw'coiiwensalkin. as required by Seclion 3700 Of Ihe Laborer number are: Insurance Co PoicyNo. ExptaVon Dale Bsection need not be convleled if Ihe pemit Is for one Itundred dobs ($100) or less. CeiWicate of Exenipdon: I cert^ Ihat h tie perfomiance of 8B mk (v CdKxnia WARNm6:Faili«Btosaciira>afkm'caniptnstfanGcweragei(uniaarful, addition to the cost of compensation, damages *s provided for In Sedian 3708 of the Lifaor code, interest and attomey't fees. ^ CONTRACTOR SIGNATURE •AGENT DATE OWNEfV-BUILDER DECLARATION f/WW aflim ffiaf f am eaeiTipf fofli (3an^^ I >T I, as owner cf Vie properly or my eniployees (Ml wages as ttieir sole conipensalion,*i dotted License Law does not apply to an owner of property vriwbuids or Improw ^ysale. If, hotrever, tie bidding w jmprewenieiit is sold wittm I I, as owrier of the piDperty, am ei<clusr»ely contracting wilti licensed contract 7044, Business and Professions Ckxle: The Contradof's License Law does not apply to an owner of property who buids or impre»es tieteon, and contracts for such prejeds wilh ooi4ractor( f~| I am exempt under Seclion Business and Prolessions (kide fbr tils reason: l.lpersonallyplantoprDMdettiemajorlabaandmdeiialstorconstruclionofttiepioposedpiDperty I Ives I /THo have noQ signed an appicafion tor a buldng pennit for tie pioposed work. , a I have conhacied witti tie tolowing peison (llmi) to provide tie pnvcsedoonsl^^ /f//<^ /'/2jC^£f^ COflyANy 4.1 plan to provide poittons of tie wo(1(, but I have hired ttie tolkjwing person to cooidinato, supenrise a^ 5.1 vvtt provkle some of ttie work, but I ha\e conbajled (hired) tie foltowing pers(»s to previa •AGENT DATE COMPLETE THIS SECTION FOR N O N - R E S I O E N T I A L BUILDING PERMITS ONLY Is ttie apBicant or ttoboWnaocoBantiBOuiredtosubinl a business plan, acutely hazanto PlBsiey-TannerlteaRtousSubstanceAcooinlAct? O^es LUNO Is the aonfcant or fiiture buWngocciiiantieauiredtooblain a pennit torn tie air coluSoncontoldis LJYes I I No lsthefacilNytobecanstucledwittiin1,000<Betofttieoulerbaundaiyafaschoclsile? FlYes lINo IF ANY OF THE ANSWBIS ARE YES. A FINAL CERHFCATE OF OCCUmiCr IMY NOT BE ISSUED UNLESS THE EMERGEMrY SERMCES AND THE ARPOUJUTION CONTROL DISTRICT. CONSTRUCTION LENDING AGENCY I hereby affinn Ihat there is a condnicdon lendhg ageiH^r fty Lendei'sName Lender's Address APPLICANT CERTIFICATION IceitifythatI have read the appicalioH and Stale ttattheabo iMjiiwinijiiul willliittlii WiiiiitMliiaBnllrpliMniTarnmar laorrlBrnini%wlhil<TlynnliMnrniiwMl'it<rlawTn1^iackBl»^ lheRi)yaitiari2eiepresei<ali«eoffieCl^of(:arist»dtoenlerupm AGAINST AaUABKJT1S,Jl£GiyerrS,00S1B AND B(PB^ WHICH MAYfN ANY WAY AC^ OSHA: An C)SHA peiinl is lequlnd fbr eMavaions over SCr deep aid demoilon or ainsl^^ E)(PHMTX)N: Beiy peiinit issued by lie Biddng OHdd under tie piDwsians of ttK 180 days feom lie dale of such peiinlaif tie buidkigar«akauttioiizBd by such peiinil is suspen ^STAPPUCANT'S SIGNATURE DATE City of Carlsbad BIdg Inspection Request For 06/12/2012 Permit* CB120142 Title: SMITH RES- ADD 299 SF OFFICE Description: TO 1ST FLOOR, COVERED ENTRY 83 SF Inspector Assignment: PY 2849 CACATUA ST Lot: Type: RESDNTL Sub Type: RAD Job Address: Suite: Location: APPLICANT B & W ARCHITECTS Owner: LAFLIN-SMITH TRUST 12-06-89 Remarks: Phone: 7604150102 Inspector: Total Time: CD Description 19 Final Structural 29 Final Plumbing 39 Final Electrical 49 Final Mechanical Requested By: MIKE Entered By: JANEAN Act Comments Comments/Notices/Holds Associated PCRs/CVs/SWPPPs Origmal PC# SW120019 ISSUED SMITH ADDITION; Inspection Historv Date Description 04/17/2012 17 Interior Lath/Drywall 04/17/2012 18 Exterior Lath/Drywall 04/13/2012 16 Insulation 04/11/2012 14 Frame/Steel/Bolting/Welding Act Insp Comments AP PY AP PY AP PY PA PY REVISE PLANS FOR ROOF FRAMING W/STAMP AND SIGNATURE OF ARCHITECT Inspection List Permit*: CB120142 Date Inspection Item Type: RESDNTL RAD Inspector Act SMITH RES- ADD 299 SF OFFICE TO 1ST FLOOR, COVERED ENTRY 83 SF Comments 06/12/2012 89 Final Combo -Rl 06/12/2012 89 Final Combo PY AP 04/17/2012 17 Interior Lath/Drywall PY AP 04/17/2012 18 Exterior Lath/Drywall PY AP 04/13/2012 16 Insulation PY AP 04/11/2012 14 Frame/Steel/Bolting/Weldin PY PA 04/11/2012 23 Gas/Test/Repairs PY AP 04/11/2012 24 Rough/Topout PY AP 04/11/2012 34 Rough Electric PY AP 04/11/2012 44 Rough/Ducts/Dampers PY AP 03/30/2012 83 Roof Sheathing/Ext Shear PY AP 03/12/2012 11 Ftg/Foundation/Piers PY AP REVISE PLANS FOR ROOF FRAMING W/STAMP AND SIGNATURE OF ARCHITECT REMOVE GAS VALVE OR MAKE ACCESSIBLE Wednesday, June 13,2012 Page 1 of 1 EsGil Corporation In (PartnersRip witH government for <BuiC£ing Safety DATE: 02/29/12 q APPIJCANT JURISDICTION: Carlsbad • PLAN REVIEWER • FILE PLAN CHECK NO.: 12-0142 SET: REV PROJECT ADDRESS: 2849 Cacatua Street PROJECT NAME: Room Addition/Covered Porch for Smith Residence (Set III consist of two minor revisions) 3 The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. I I The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. I I The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. I I The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. I I The applicant's copy of the check list is enclosed for the jurisdiction to fon/vard to the applicant contact person. I I The applicant's copy of the check list has been sent to: EsGil Corporation staff did not advise the applicant that the plan check has been completed. I I EsGil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Telephone #: Date contacted: (by: ) Email: Mail Telephone Fax In Person REMARKS: City to place soils stamp on the plans at issuance. By: Ray Fuller Enclosures: EsGil Corporation • GA • EJ • PC (P) 02/27/12 9320 Chesapeake Drive, Suite 208 • San Diego, Califomia 92123 • (858)560-1468 • Fax (858) 560-1576 EsGil Corporation In (Partnersfiip witH government for BuiUing Safety DATE: 02/14/12 a^V^PPBSi^T JURISDICTION: Carlsbad • PLAN REVIEWER • FiLE PLAN CHECK NO.: 12-0142 SET: II PROJECT ADDRESS: 2849 Cacatua Street PROJECT NAME: Room Addition/Covered Porch for Smith Residence I I The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. XI The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. I I The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. I I The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. I I The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. I I The applicant's copy of the check list has been sent to: EsGil Corporation staff did not advise the applicant that the plan check has been completed. I 1 EsGil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Ji Telephone #: Date contacted: (ii?^^ Email: Mail Telephone'— Fax In Person 3 REMARKS:!J^lans to be stamped and signed by person responsible for preparation. City to place soils stamp on the plans at issuance. By: Ray Fuller Enclosures: EsGil Corporation • GA • EJ • PC (P) 02/08/12 9320 Chesapeake Drive, Suite 208 • San Diego, Califomia 92123 • (858)560-1468 • Fax (858) 560-1576 EsGil Corporation In Partnersfiip witH government for (Building Safety DATE: 02/01/12 Q^EEU^ANT JURI§, JURISDICTION: Carlsbad •"^[XNREVIEWER • FILE PLAN CHECK NO.: 12-0142 SET: I PROJECT ADDRESS: 2849 Cacatua Street PROJECT NAME: Room Addition/Covered Porch for Smith Residence I I The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. I I The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. I I The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. ^ The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. I I The applicant's copy of the check list is enclosed for the jurisdiction to fonward to the applicant contact person. XI The applicant's copy of the check list has been sent to: Max Wuthrich PO Box 7223 Rancho Santa Fe, Ca. 92067 I I EsGil Corporation staff did not advise the applicant that the plan check has been completed. EsGil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Max Wuthrich Telephone #: (858) 756-1788 Date contacted: 2^1 2.' / 2. (by: ^ ) Email: bwarc(5).Dacbell.net Fax #: (858) 756-1735 ^ Mail ^^elephone ^ Fax In Person • REMARKS: By: Ray Fuller Enclosures: EsGil Corporation • GA • EJ • PC 01/26/12 9320 Chesapeake Drive, Suite 208 • San Diego, Califomia 92123 • (858)560-1468 • Fax (858) 560-1576 Carlsbad 12-0142 02/01/12 PLAN REVIEW CORRECTION LIST SINGLE FAIVIILY DWELLINGS AND DUPLEXES PLAN CHECK NO.: 12-0142 JURISDICTION: Carlsbad PROJECT ADDRESS: 2849 Cacatua Street FLOOR AREA: Addition 299 Covered Entry 83 REMARKS: DATE PLANS RECEIVED BY JURISDICTION: 01/24/12 DATE INITIAL PLAN REVIEW COMPLETED: 02/01/12 STORIES: 1 HEIGHT: 14 ft per CBC DATE PLANS RECEIVED BY ESGIL CORPORATION: 01/26/12 PLAN REVIEWER: Ray Fuller FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the International Residential Code, International Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinance by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit. Present California law mandates that construction comply with the 2010 edition ofthe California Code of Regulations (Title 24), which adopts the following model codes: 2009 IRC, 2009 IBC, 2009 UPC, 2009 UMC and 2008 NEC. The above regulations apply, regardless ofthe code editions adopted by ordinance. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 105.4 of the 2009 International Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed UP ttie recheck process, please note on tiiis list (or a copy) wtiere each correction item lias been addressed, i.e.. plan sheet number, specification section, etc. Be sure to enclose the marked UP list wiien vou submit the revised plans. Carlsbad 12-0142 02/01/12 1. The following note should be given with each correction list: Please make all corrections, as requested in the correction list. Submit four new complete sets of plans for commercial/industrial projects (three sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. 2. All sheets of plans must be signed by the person responsible for their preparation. (California Business and Professions Code). 3. Provide plans, calculations or worksheets to show compliance with current energy standards. The required energy calculations for this project were not provided. The relocated glazing must comply window /doors must comply with current U and SiHGC values (.40 or less) if using prescriptive measure. 4. The regulations require a properly completed and properly signed Form CF-1R (4 pages) to be either imprinted on the plans to allow the building inspector to readily compare the actual construction with the requirements of the approved energy design. Verify Owner/designer has sign the CF1-R forms. 5. Specify, on the building plans, that all of the mandatory energy features are indicated on the plans and specifications or include a completed MF-1R form on the plans. 6. Please revise the section numbers and notes on the plans to match the 2009 International Residential Code (IRC), as adopted in the 2010 California Residential Code. Type of construction on cover sheet should be VB (IBC/IRC) instead of VN. (UBC). 7. Please provide a partial dimensioned existing floor plan for rooms adjacent to proposed addition. Specify on plans the use of all rooms adjacent to proposed addition and all existing window sizes and how they open to verify that room addition have not adversely affected any required egress requirements and the existing adjacent rooms have the minimum required 1/10th the area in light and 1/20th the area in ventilation. Carlsbad 12-0142 02/01/12 8. Please verify adequate footings shown for support of the 6 xlO beam as well as the PSL's on the left side. 9. Specify grade of beam and 6 xlO and 6 x10 spanning 14 plus ft appears to be marginal. Please provide calculations to justify. 10. Missing header size at 6ft window and verify adequate and include in design the 6 ft of overhang. 11. Show or note on plans that all rake walls are to be ballooned framed. 12. Section on A5 is noting 2 x4 framing with R-19 (minimum 2 x6 required). 13. Please provide a cross section /elevation that clearly reflects how windows/wall are to be sup[ported as shown on the west elevation. Assume the PSL's are to be below to support window and wall framing above. If this is the case then plans to reflect how supported at north and south walls i.e. posts , post to beam connections etc. 14. If PSL's are below then no header shown above windows to support the king post/ridge beam, above? Appears will need a adequate header spanning 7 ft that is capable of supporting point load and the PSL's are designed to support point loads. 15. Could not determine why west elevation is reflecting a window at the existing portion of dwelling on A3 and not shown on floor plan on A2? • CITY of CARLSBAD REQUIREMENTS 16. All new residential buildings, including additions, require a soils report. An update letter is required ifthe report is more than 3 years old. If a room addition is less than 500 sq. ft. in area and only one story, then a soils report is not required. The maximum allowable soil bearing value used in any design must be 1000 psf for this exception. Keynote 5 on S1 states 1500 assumed ? • To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, etc, • Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. • The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Ray Fuller at Esgil Corporation. Thank you. Carlsbad 12-0142 02/01/12 [DO NOT PAY- THIS IS NOT AN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION: Carlsbad PLAN CHECK NO.: 12-0142 PREPARED BY: Ray Fuller DATE: 02/01/12 BUILDING ADDRESS: 2849 Cacatua Street BUILDING OCCUPANCY: RS U TYPE OF CONSTRUCTION: VB BUILDING PORTION AREA ( Sq. Ft.) Valuation Multiplier Reg. Mod. VALUE ($) Addition 299 131.73 39,387 Covered Entry 83 9.59 796 Air Conditioning Fire Sprinklers TOTAL VALUE 40,183 Jurisdiction Code cb By Ordinance Hdg. Permit Fee k)y OitJinanoe Plan Check Fee by Ordinance Type of Review: 0 •Repetlive Fee ^ Repeats Complete Review • Other j_j Hourly EsGil Fee • Stmctural Only Hr. @ $386.99 $251.54 $216.71 Comments: Sheet 1 of 1 macvalue.doc + CITY OF CARLSBAD BUILDING PLANCHECK CHECKLIST E-36 Development Services Land Development Engineering 1635 Faraday Avenue 760-602-2750 www.carlsbadca.gov ENGINEERING Plan Check for CB 12-142 Review # 2 Date: 02/17/12 Project Address: 2849 CACATUA ST Project Description: OFFICE ADDITION 299 SF (1st FLOOR) APN: 215-370-21 Valuation: $39,387 ENGINEERING Contact: KATHLEEN LAWRENCE Email: Kathleen.lawrence@carlsbadca.gov Phone: 760-602-2741 Fax: 760-602-1052 STOP! Please Read Any outstanding Issues will be marked withlXj. Please make the necessary corrections to the plans or specifications for compliance with applicable codes and standards. Submit corrected plans and/or specification to the Building division for resubmittal to the Engineering Division. Items that conform to permit requirements are marked with / ATTACHMENTS: Engineering Application Storm Water Form I i Right-of-Way Application/Info. Sheet Reference Documents OFFICIAL USE ONLY ENGir/E^RING AUTHORIZATION TO ISSUE BUILDING PERMIT BY: REMARKS: DATE: Notification of Engineering APPROVAL has been sent to via on E-36 Page 1 of 6 REV 4/30/11 CB 12-142 Review # 2 1. SITE PLAN Provide a fully dimensioned site plan drawn to scale. Show: L . J 1 PROPERTY OlMENSIOJt/ f ~] INCORRKTLY SHOWN SEE «irrACHED , ^ , Ai i / j North arrow I Existing & proposed structures / yExisting street improvements Property lines (show all dimensions) Easements Right-of-way width & adjacent streets I I Driveway widths CIIIJ Existing or proposed sewer lateral L I Existing or proposed water service CZH Submit on signed approved plans: DWG No. SHOW DRAII Show on site LOT(^E rainage patterns Building pad surface drainage must maintain a minimum slope of one percent towards an adjoining street or an approved drainage course. i ADD THE FOLLOWING NOTE: "Finish grade will provide a minimum positive drainage of 2% to swale 5' away from building". ] Existing & proposed slopes and topography jSize, location, alignment of existing or proposed sewer and water service(s) that serves the project. Each unit requires a separate service; however, second dwelling units and apartment complexes are an exception. J Sewer and water laterals should not be located within proposed driveways, per standards. Include on title sheet: / i Site address Assessor's parcel number ~ZI1 Legal description/lot number [~] For commercial/industrial buildings and tenant improvement projects, include: total building square footage with the square footage for each different use, existing sewer permits showing square footage of different uses (manufacturing, warehouse, office, etc.) previously approved. r~~1 Show all existinq use of SF and new proposed use of SF. Example: Tenant improvement for 3500 SF of warehouse to 3500 SF of office. Lot/Map No.: Subdivisionrfract: Lot 506 Reference No(s): Map no. 7076 E-36 Page 2 of 6 REV 4/30/10 CB 12-142 Review # 2 5. GRADING PERMIT REQUIREMENTS The conditions that require a grading permit are found in Section 15.16 of the Municipal Code. • "^Inadequate information available on site plan to make a determination on grading requirements. Include accurate grading quantities in cubic yards (cut, fill, import, export and remedial). This information must be Included on the plans. If no grading is proposed write: "NO GRADING" I Grading Permit required. NOTE: The grading permit must be issued and rough grading approval obtained prior to issuance of a building permit. Graded Pad Certification required. (Note: Pad certification may be required even if a grading permit is not required.) All required documentation must be provided to your Engineering Construction Inspector per the attached list. The inspector will then provide the engineering counter with a release for the building pemnit. CZl No grading permit required. I ~1 Minor Grading Permit required. See attached marked-up submittal checklist for project- specific requirements. 6. MISCELLANEOUS PERMITS 1 RIGHT-OF-WAY PERMIT is required to do work in city right-of-way and/or private work adjacent to the public right-of-way. Types of work include, but are not limited to: street improvements, tree trimming, driveway construction, tying into public storm drain, sewer and water utilities. 1 Right-of-way permit required for: E-36 Page 4 of 6 REV 6/30/10 CB 12-142 Review # 2 7. STORM WATER Construction Compliance COMPLETE C NAME AND; INFO ON; STORMWATER COMPLIANCE FORM i/l Project Threat Assessment Form complete. iclosed Project Threat Assessment Form incomplete. Requires Tier 1 Storm Water Pollution Prevention Plan. Please complete attached fomri and return (SW 12-19 ) Requires Tier 2 Stonn Water Pollution Prevention Plan. Requires submittal of Tier 2 SWPPP, payment of processing fee and review by city. Post-DeveJopment (SUSMP) Compliance COMPLBrE STORM WATEK^TDS QUKTIONNAIRE rlGNATURE BOX PG 3 c X (3 storm Water Standards Questionnaire complete. Storm Water Standards Questionnaire incomplete. Please make the corrections, re-sign the questionnaire and resubmit with next submittal. r J Project is subject to Standard Storm Water Requirements. See city Standard Urban Storm Water Management Plan (SUSMP) for reference. :tp://www.carlsbadca.qov/business/buildinq/Documents/EnaStandsw-stds-vol4-ch2.pdf Project needs to incorporate low impact development strategies throughout in one or more of the following ways: Q Rainwater harvesting (rain barrels or cistern) Q Vegetated Roof r I Bio-retentions cell/rain garden CZ] Pervious pavement/pavers C.J Flow-through planter/vegetated or rock drip line f "1 Vegetated swales or rock infiltration swales Downspouts disconnect and discharge over landscape I I Other: E-36 Page 5 ot 6 REV 4/30/10 >v PLANNING DIVISION Development Services <^W$> BUILDING PLAN CHECK Planning Division ^ CITY OF REVIEW CHECKLIST I635 Faraday Avenue CARLSBAD P-28 (760) 602-4610 www.carlsbadca.gov Plan Check No. CB120142 Address 2849 CACATUA ST Date 1/24/12 Review # 1 Planner GINA RUIZ Phone (760) 602- 4675 APN: 215-370-21-00 Type of Project & Use: ADDITION Net Project Density: DU/AC Zoning: Ell General Plan: RLM Facilities Management Zone: 6 CFD (in/out) #_Date of participation: Remaining net dev acres: (For non-residential development: Type of land use created by this permit: ) REVIEW #: 12 3 Legend: ^ Item Complete • Item Incomplete - Needs your action IE! • • Environmental Review Required: YES • NO |EI TYPE DATE OF COMPLETION: Compliance with conditions of approval? If not, state conditions which require action. Conditions of Approval: • • Discretionary Action Required: YES • NO IE! TYPE APPROVAL/RESO. NO. DATE PROJECT NO. OTHER RELATED CASES: Compliance with conditions or approval? If not, state conditions which require action. Conditions of Approval: • • Coastal Zone Assessment/Compliance Project site located in Coastal Zone? YESQNO^ CA Coastal Commission Authority? YES • NO Q If California Coastal Commission Authority: Contact them at - 7575 Metropolitan Drive, Suite 103, San Diego, CA 92108-4402; (619) 767-2370 Determine status (Coastal Permit Required or Exempt): n • Habitat Management Plan Data Entry Completed? YES • NO IE1 If property has Habitat Type identified in Table 11 of HMP, complete HMP Permit application and assess fees in Permits Plus (A/P/Ds, Activity Maintenance, enter CB#, toolbar, Screens, HMP Fees, Enter Acres of Habitat Type impacted/taken, UPDATE!) • • Inclusionary Housing Fee required: YES • NO ^ (Effective date of Inclusionary Housing Ordinance - May 21,1993.) Data Entry Completed? YES • NO • (A/P/Ds, Activity Maintenance, enter CB#, toolbar, Screens, Housing Fees, Construct Housing Y/N, Enter Fee, UPDATE!) • • Housing Tracking Form (form P-20) completed: YES • NO • N/A |E1 p-28 Page 1 of 2 07/11 Site Plan: S • • Policy 44 - Neighborhood Architectural Design Guidelines IE! • • 1. Applicability: YES • NO lEl S • • 2. Project complies: YES • NOO • • • • • • Zoning: 1. Setbacks: Front: Required 20; Shown 20' Interior Side: Required 7 Shown 7.7' Street Side: Required N/A Shown N/A Rear: Required 15>£ Shown 100' Uphill slope: (Y) Cut into slope? (N) 2. Accessory structure setbacks: N/A Front: Interior Side: Street Side: Rear: Structure separation: 3. Lot Coverage: Required Shown. Required Shown. Required Shown Required Shown. Required Shown. Reauired 40% MAX Shown 19% • • 4. Height: Required 30' MAX Shown 19.1' • • 5. Parking: Spaces Reauired 20'x20' Shown 22'x27' (breakdown by uses for commercial and industrial projects required) Residential Guest Spaces Required Shown • • Additional Comments OK TO ISSUE AND ENTERED APPROVAL INTO COMPUTER